Zen+Assembly+Manual+2.0

March 20, 2018 | Author: francesco raggi | Category: Tent, Hvac, Ac Power Plugs And Sockets, Door, Pregnancy


Comments



Description

FLOAT TENTTM ASSEMBLY INSTRUCTIONS VIDEO INSTRUCTIONS: zenfloatco.com/setup Check online for version updates at: ZenFloatCo.com. Version 2.0, updated 11.17.14. Water Care Info provided by, www.floattanksolutions.com CONTENTS SHORT POLES - 14” MEDIUM POLES - 34” LONG POLES - 42” 6x 8x 6x T-CONNECTOR METAL DOOR POLES PLASTIC DOOR POLES 2x 2x 4x TOP CONNECTOR RIGHT CONNECTOR 1x LEFT CONNECTOR 2x 2x VINYL TENT COVER VINYL TUB DRIP MAT 1x 1x 2x HEATING PADS AIR VENTS TEMP CONTROLLER 2x 2x 1x UV FILTER FILTER BAG FILTER HOSE 1x 1x 1x FLOW SWITCH TOP CONNECTOR BOLT TOP CONNECTOR NUT GROUND PROBE 1x 1x 1x . 42” SHORT POLES .1. ASSEMBLE WATER TUB To verify there were no punctures in transit.14” .com NOTE: Poles are threaded through sleeves on the water tub LONG POLES . Tel: 801-871-5140 Email: info@zenfloatco. If you have any leaks contact us immediately. move the tub to an outdoor area and fill up. NOTE: Make sure open end of corner pieces point toward the center of float tent. . MED POLES .34” ASSEMBLE PYRAMID FRAME Assemble the frame onto existing tub. then make the final connection at the tip of pyramid last.2. 3. 1 ft (30 cm) IMPORTANT HEAT HEAT VERIFY THE PADS ARE THE CORRECT SIDE UP! They will have markings on each pad to verify which side is up. CHOOSE PROPER PLACEMENT Allow at least 1 ft (30cm) of space between the Float Tent and room walls for maintenance. . While the heating pad is activated.Lay down radiant pads so they are just barely touching each other. THIS SIDE UP THIS SIDE UP BURNS Use heating pads only as directed. Confirm that floor load bearing capacities are able to support the float tent weight when filled and occupied. LOAD BEARING CAPACITY & WATER The float tent is intended for use by one person at a time. do not leave in contact with any object other than the waterproof liner as directed. Confirm that the heating element in the heating pad is facing upward. . and avoid direct contact of skin with the heating pad. With the liner in place. make sure tub legs are not on top of pads. cover with waterproof liner and place tub directly over pads. The liner should stick out evenly on three sides. Position the side with filter loops on the end the door will face. but there should be excess on the side where the tent door will face.4. IMPORTANT TENT POLES OFF HEATING PADS TENT POLES ON HEATING PADS . the tub will sit exactly over them. TENT DOOR DRIP MAT 10 in NOTE: The side of the tub you will enter on has three big loose loops of canvas inside the tub to hold the filter. PLACE LINER AND TANK IN PLACE With heating pads properly placed. To avoid damage. 5. INSTALL FILTRATION SYSTEM Thread the hose through the channels on the side of the tank. The pump will be located at the back of the tank. CONNECTS TO HOSE FILTER BAG . and the filter bag will sit next to the door. The pads will heat almost too hot to touch. If it powers off they are good. Our products have GFCI’s built into the cords. UV FILTER TEMP SENSOR GFCI GROUND PROBE TO WALL HEAT PADS NOTE: Plug in the pads temporarily to verify they weren’t damaged in transit. For safety. Be sure GFCI’s rest on a raised surface above plug level while plugged into the wall. GFCI’s cut the power if the electricity ever comes in contact with the water. Temperature Controller. PLUG -IN AND VERIFY SAFETY Plug Grounding Probe. they will save your life! Test them once a month by pushing the “test” button on the GFCI. If an accident were to happen. . and UV Pump into a wall outlet.6. Make sure the Grounding Probe is plugged in and submerged at all times. the tank water should be electrically grounded due to a possible induced current from the heaters. Do not allow any electric appliance within three feet of the float tent. NOTE: The grounding probe may plug directly into the wall. EVERYTHING SHOULD PLUG INTO A GFCI DEVICE. .IMPORTANT EVERYTHING MUST PLUG IN GFCI NEVER PLUG ANYTHING NEAR YOUR TANK INTO THE WALL DIRECTLY. and never introduce electric appliances into the water. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. RISK OF ELECTRICAL SHOCK Plug Install the float tent at least three feet from all electrical outlets and metal surfaces. as this may result in serious bodily injury or death. . fill the tank with five inches of water. FILL TANK WITH EPSOM SALT This part takes time. Don’t rush it. Do not ingest the water in the float tent.7. just enjoy the process. Add a couple bags of Epsom salt. other than Epsom salt as directed. IN-LINE WATER FILTER 5 INCHES OF WATER (13 cm) ADDITIVES AND SALT INGESTION Do not add additives (such as bubble bath and bath salts) to the water in the float tent. (100 lbs) at a time mixing in fully as you go. Once smooth. Start by smoothing out creases on the tub floor before adding water. Once all the salt is added. SUITABLE INSURANCE Improper use of this product may create certain risks of damage to person and property. including water damage. Please consult with your insurance advisor for information about suitable insurance coverage. Always drain the float tent as directed before moving the float tent to prevent flooding. It may be easiest to stand in the water and mix it around with your feet. fill until the water level reaches 10 inches.Agitate water and salt by stirring and mixing. . Avoid using sharp objects when near the float tent as this could puncture the float tent and cause flooding. Never pull on the tent to remove poles. Always detach the tent from the tub before disassembling the tent. FILL TO 10 INCHES OF WATER (25 cm) PROPERTY DAMAGE Do not overfill the float tent. Never leave the float tent unattended when filling with water. Be aware that water rises as you enter the float tent. 8. TEMP CONTROLLER TEMP SENSOR (≈6 in deep) You should now see the heating indicator light turn on and within minutes be able to feel warmth comping up through the pads in your tank. The Temperature will now display a temperature detected by the attached temperature sensor. The first thing you will notice is a slight glow from the UV filter. UP To set the temperature controller. and use the top and middle buttons to adjust DOWN SET To change degrees to Celsius hold the top and middle (up and down) buttons simultaneously for three seconds. Set Temperature Controller to : 93. Securely place sensor in the water toward the bottom of the tank to allow the Temperature Controller to auto-regulate water temperature through heating pads.5º F (34º C) Anticipate the temperature rising approximately 1º F (1/2º C) . . Plug the UV Filter in. single click bottom button to set the temperature. TURN ON AND VERIFY SETTINGS Plug the two heating pads into the Temperature Controller. per hour. . INSTALL TENT COVER Float Tent Cover will have a tight fit. Work each corner one at a time sliding them down a few inches each time around.9. INSTALL TENT DOOR Door poles go in sleeves located around the perimeter of both the tent wall and tent door flap. Each pole will have a number on it.10. Insert poles in their corresponding pole sleeves as illustrated below. tal) e 6 (m 7( 1( m ACTUAL DOOR 8 m et et al) al) DOOR FRAME 2 3 4 5 3 1 4 7 2 5 6 8 . Tuck in three tabs to start and use finger to tuck the fourth in. ASPHYXIATION Lack of ventilation may cause injury or death.11. INSTALL AIR VENTS Insert vent stem through vent holes on the back of the Float Tent and snap together with the other half of the vent on the other side. Before entering the float tent. confirm that the air vent stems are inserted as directed and functioning properly. . 12. free the condensation liner out from the cover and tank walls. Allow the liner to hang free so any condensation dripping down the tent walls will drip down the liner and back into the tank. . DO NOT EVER FLOAT IF THE TEMPERATURE IS ABOVE 96º F. PLACE CONDENSATION LINER From the inside of the Float tent. OR IF IT FEELS ABNORMALLY WARM. CONDENSATION LINER IMPORTANT ALWAYS CHECK YOUR TEMPERATURE BEFORE GETTING INTO THE FLOAT TANK. FIRE HAZARD Keep all flame and other heat sources away from the float tent. and possible drowning. DRUGS AND ALCOHOL USE Do not use drugs or alcohol before or during use of the float tent. including the tent fabric. The use of drugs or alcohol may increase the risk of injury. The fabric may burn or melt if placed in contact with any flame or other heat source. Closely watch all children in and around the float tent. and never leave any child unattended inside the float tent or with access to the float tent. CHILDREN The float tent should not be used by children under the age of [12]. PREGNANCY AND OTHER HEALTH CONCERNS Users with high blood pressure or who are pregnant should consult a physician before using this product. unconsciousness. SLIPPING AND FALLING To avoid falling or other injury. use caution when entering or exiting the float tent. . It is recommended that all doors and windows to the room containing the float tent remain locked to limit access. 4730 Riverside Drive Salt Lake City.Zen Float Co.com . UT 84123 USA Tel: (855) Zen-Float Email: info@ZenFloatCo.
Copyright © 2024 DOKUMEN.SITE Inc.