BVANE PUMPS Output Flow at 1200 r /min at No-Load Pump Type Maximum Operating Pressure MPa (PSI) "PVL" Series Single Pumps 5 (730) Single Pumps 7 (1020) Double Pumps 7 (1020) Combination Pumps 7 (1020) "PV2R" Series Single Pumps 21 (3050) "PV2R" Series Double Pumps 21 (3050) "PV11R" Series Single Pumps 40 (5800) .3 1 .5 1 2 2 5 5 10 20 10 20 50 100 50 200 U.S.GPM 100 200 Pub. EC-0116 PVL1 50T 150T 250F Small Volume Large Volume (50) (50) (150) (150) (250) (250) Small Volume Large Volume (50) (50) (150) PV2R1 Small Volume Catalogue No. 500 800 L /min PV11R20 Pub. EC-0117 PV2R2 PV2R3 PV2R4 (PV2R1) (PV2R2) (PV2R3) Large Volume (PV2R2) (PV2R3) (PV2R4) PV11R10 500F Pub. EC-0118 Pub. EC-0119 Pub. EC-0116 "PVL" SERIES VANE PUMPS Fixed Displacement - Single PVL1 Up to 5 MPa (730 PSI), 10.6 cm3/rev (.647 CU.IN./rev) The PVL series single pumps are designed for use with small size machine tools requiring comparatively low pressure and small flow rates. Graphic Symbol Specifications Geometric Displacement cm3/rev (cu.in./rev) Model Numbers PVL1- 2-∗-RA-∗-31/3180/3190 PVL1- 3-∗-RA-∗-31/3180/3190 PVL1- 4-∗-RA-∗-31/3180/3190 Output Flow & Input Power 5 (730) Refer to Page 5 Shaft Speed Range r/min Max. Min. 1800 950 Approx. Mass kg (lbs.) Flange Foot Mtg. Mtg. 1.5 (.092) 2.7 (.165) 3.7 (.226) PVL1- 6-∗-RA-∗-31/3180/3190 5.7 (.348) PVL1-11-∗-RA-∗-31/3180/3190 10.6 (.647) PVL1- 8-∗-RA-∗-31/3180/3190 Max. Operating Pressure MPa (PSI) 3.3 (7.3) 5.7 (12.6) 7.8 (.476) However, when starting the pump at low speed, maximum viscosity is restricted. Refer to Page 2, item "Hydraulic Fluids" for maximum viscosity. Model Number Designation PVL1 -4 -L -R A -K -31 ∗ Series Number Nominal Displacement cm3/rev Mounting Direction of Rotation Discharge Port Position Shaft Extension Design Number Design Standard PVL1 Threaded Connections 2 3 4 6 8 11 L: Foot Mtg. F: Flange Mtg. (Viewed from Shaft End) R: Clockwise (Normal) K: Keyed Shaft 1 A: Upwards (Normal) 31 Refer to 2 V : Tang Shaft 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details. 2. Design Standards: None ........... Japanese Standard "JIS" 80 ............... European Design Standard 90 ............... N. American Design Standard No.1 B "PVL" Series Single Pump - Type "PVL1" Hydraulic Fluids / Instructions VANE PUMPS Hydraulic Fluids 1. Type of Hydraulic Fluids Petroleum Base Oils ............Use R&O (Rust and Oxidation inhibitor) type oils or anti-wear type oils. (equivalent to ISO VG-32 or 46) Note: Only Petroleum Base Oils can be used for hydraulic fluids. 2. Recommended Viscosity and Oil Temperature Viscosity ranging between 20 - 400 mm2/s (100 - 1800 SSU). Oil temperatures between 0/+70°C (32 - 158°F) Use hydraulic fluids which satisfy the recommended viscosity and oil temperatures given above. Note that if the PVL1 pump is started at a low speed of 950 r/min, the maximum fluid viscosity is limited to 200 mm2/s (910 SSU). 3. Control of Contamination Contamination of hydraulic fluids results in pump failures and reduced pump lives. Carry out sufficient contamination control for hydraulic fluids and keep contamination level within NAS class 12. Also, use a 100 μ m (150-mesh) tank filter on the suction side and install it more than 50 mm (2 in.) away from the tank bottom. Instructions 1. Alignment of Shaft Employ a flexible coupling whenever possible, and avoid any stress from bending or thrust. Maximum permissible misalignment is less than 0.1 mm (.004 inches) TIR and maximum permissible misangular is less than 0.2°. 2. Suction Pressure Set the suction pressure within -20 to +30 kPa (5.9 in. Hg vacuum to +4.3 PSIG) at the pump inlet. In addition, use suction pipes having the sizes shown in the dimensional drawings. If the pump is installed above the tank level, set the suction port more than 1.0 m (3.3 ft.) below from the oil level. 3. Precautions at Starting At an initial operation or at an operation after a long rest, the pump may have difficulty in sucking up the fluid. In such cases, an air bleed valve should be installed beforehand on the discharge side (model No. ST1004-∗-10∗, catalogue No. Pub. EC-3001.), or discharge air by slightly slackening the connection on the discharge side. At starting, operate the pump intermittently as far as possible with no load. For fluid viscosity at starting, see the item "Hydraulic Fluids" above. 4. Other Precautions If a PVL1 series single pump is used at speed below 1200 r/min, install the pump with the suction port upside so that the pump can suck up the fluid easily at starting. No.2 2264) 15 Dia.1969) 4.23) 74(2.05) 97(3.".F 1/2 NPT 3/8 NPT PVL1-∗-F-RA-K-31 PVL1-∗-F-RA-K-3180 PVL1-∗-F-RA-K-3190 DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.54) 10 (.47) 12(.5(.663) 52 (2.89) For other dimensions. Rc 1/2 Rc 3/8 1/2 BSP.81) 80(3.852(. No. Discharge Port "B" Thd.3 . For other dimensions.12) 75 (2.71) 17.854) 127(5.Type "PVL1" VANE PUMPS Installation Drawing Flange Mtg. Spotface 4 Places 138(5. 14. "B" Thd. Keyed Shaft: PVL1-∗-F-RA-K-31/3180/3190 49.43) 50 (1.59) 5.50) 72."PVL" Series Single Pump .47) 55 (2..95) A 72.99(1.669) 16. refer to "Flange Mtg.5898) 46 (1.9681) 49.82) 7(.5906) Dia.80(. PVL1-∗-F-RA-V-31/3180/3190 Suction Port "A" Thd.43) Discharge Port Position 49.5 (2.75(.97(. refer to "Keyed Shaft".854) 175(6.968) 95(3.43) Dia.2283) 5.000(.17) 34 (1.33) 18(.195) Dia.71) R12(R. A 110(4.75) 90(3.61) 20(.79) 11(. (.15) 130(5. 41 (1.12) Model Numbers "A" Thd. 138(5.00(.91) 15.9665) Dia.94) Dia.43) 5. Keyed Shaft: PVL1-∗-L-RA-K-31/3180/3190 11(.39) B Tang Shaft.000(.5 (2.982(. Through 24(.95(1.64) 96(3.F 3/8 BSP.1957) Key Width 19 (.00) 13 (.74) 67 (2.78) 38 (1.51) 3(.34) 18 (. . . . . . . . . . . one metre (3. . . please do it carefully after reading through the relevant instructions in the Operator's Manual. . 9 Oil Seal ISD 20 35 8 1 10 O-Ring S 60 2 11 Bearing 6003 2 Remarks Included in Seal Kit (Kit No. . . . . . . . . . 20 mm2/s (100 SSU) Point of measurement . . . . . . . . . : KS-PVL1-31) Typical Noise Level Characteristics Measuring conditions Oil viscosity . . . . . . . . . . . . .3 ft. . 40 dB (A) dB(A) 55 dB(A) 55 dB(A) 55 dB(A) 55 50 50 50 50 45 40 0 1 0 No. .4 2 3 4 5 MPa 200 400 600 PSI 730 Pressure 45 40 0 1 0 2 3 4 5 MPa 200 400 600 PSI 730 Pressure Noise Level PVL1-6 Noise Level PVL1-4 Noise Level PVL1-3 Noise Level PVL1-2 45 40 0 1 0 2 3 4 5 MPa 200 400 600 PSI 730 Pressure 45 40 0 1 0 2 3 4 5 MPa PSI 200 400 600 730 Pressure . . PVL1-∗-∗-RA-∗-31/3180/3190 X 3 4 5 16 2 15 17 6 10 12 1 11 9 13 7 8 20 19 14 X 18 Section X-X Item Name of Parts Part Numbers Qty. . . . . . . . . . . . . . . . . . . . ."PVL" Series Single Pump . . . . . .) horizontally away from pump head cover Back ground noise level . . . . . . . . . . . . . . .Type "PVL1" VANE PUMPS Spare Parts List / Typical Pump Characteristics CAUTION When making replacement of seals or bearing. . . . . . . . . . . . . . . . . . . . . . . . . . . 8 10 2.6 1.2 0.2 kW 6 1000 r/min 1000 r/min 0 0.8 0 0 MPa kW 1.8 kW 0.GPM 7 1.S.2 1.0 0.0 4 8 400 600 730 PSI Pressure 200 0 3 400 600 730 PSI Pressure 200 L /min U.0 1.2 Input Power 2 1800 r/min 0 0 1 200 2 3 4 5 .4 1000 r/min 2.6 0.0 1.2 Input Power Output Flow 2.GPM L /min 3.8 3 0 0 MPa 400 600 730 PSI Pressure No.5 8 1.2 4 .6 5 .S.2 .6 0.6 0 0 MPa PVL1-11 3.2 .S.0 .0 1.3 1.GPM L /min .2 1.8 1500 r/min 4 HP 1.GPM L /min 5 1.4 1.8 1 HP 1.3 0 .4 1.8 1.0 Input Power L /min U.5 Input Power Output Flow U.S.6 HP .GPM 11 2.6 0.4 0 0 MPa 400 600 730 PSI Pressure Output Flow 1.0 12 2.4 1000 r/min 2.2 0.5 .2 1200 r/min 0 1.S.0 1200 r/min 0.4 0 200 3 4 5 1 2 3 4 5 .4 3 0.4 Output Flow Output Flow 1.4 .8 1000 r/min .1 0 1 2 4 5 0.8 0 HP 2.2 0 1 2 3 4 5 2.8 Input Power .8 .8 2 1.2 6 0.8 1 .4 12 5 1200 r/min PVL1-8 U.2 0.6 .6 4 L /min U.0 .4 1800 r/min 10 1800 r/min .0 1800 r/min 1500 r/min 16 kW 1200 r/min 3.2 Output Flow kW 0.6 2 PVL1-6 kW 1.4 1000 r/min 1 0.8 1200 r/min 1.GPM 20 5.6 1500 r/min 8 1500 r/min 0.6 .8 HP 1.2 .8 14 3.S.Type "PVL1" VANE PUMPS Typical Pump Characteristics B Viscosity 20 mm2/s (100 SSU) [ISO VG32 oils.4 0 PVL1-4 1800 r/min 0.5 1200 r/min .6 Input Power 1800 r/min U. 50°C (122°F)] PVL1-2 PVL1-3 1500 r/min 0 .4 0 0 MPa 400 600 730 PSI Pressure 200 4."PVL" Series Single Pump .2 2.4 .1 0 0 MPa 0 400 600 730 PSI Pressure 200 0 3 .3 0.8 6 1500 r/min 1.4 2 .6 3 .6 HP 3. 150T./rev) Single Pumps These pumps are widely used as a source of hydraulic power. driven by a common shaft.IN. Remote control or high-low two-pressure control is possible. Double. The pressure of each pump can be independently adjusted. EC-0117 50T. Graphic Symbol Double Pumps Two single pumps. Graphic Symbols Relief-relief Type Relief-relief Type 5050CT 50150CT Relief-unloading Type 5050CT 50150CT No. Graphic Symbols 5050T 50150T 150150T 50250F 150250F Combination Pumps Consists of a double pump with either two relief valves.250F SERIES VANE PUMPS Fixed Displacement-Single.Pub. Combination B Up to 7 MPa (1020 PSI). or one relief and one unloading and check valve incorporated within a common housing. They combine stable performance and robust construction with a wide range of delivery rates.1 . 498 cm3/rev (30. have two discharge ports so that the output flow can be supplied to separate circuits.34 CU. In such cases. at the values shown in the table below. 50250F 150250F -20 kPa (5. operate the pump intermittently as far as possible with no load. EC-3001. please refer to the specifications of the pump concerned.2°.1 mm (.) below from the oil level {or 0. set the suction port more than 1. ST1004-∗-10∗. Fluid viscosity and temperature Maximum viscosity for low start-up speed (Table 3) (Table 2) Fluid Petroleum Base Oils Phosphate Esters Temperature °C (°F) Viscosity mm2/s(SSU) 0-70 (32-158) 20-400 (100-1800) Pump Type 50T. Use phosphate ester type fluids.004 inches) TIR and maximum permissible misangular is less than 0. prefix "F-" to the model number because the special seals (fluororubber) are required to be used. However .7 in.) if a phosphate ester fluid is used}. 50150T -20 kPa (5. see the pump specifications. Pub. Hg Vacuum) Phosphate ester type fluid Water containing fluid -16 kPa (4.) away from the tank bottom. and avoid any stress from bending or thrust. Maximum permissible misalignment is less than 0. Suction pressure Set suction pressures. 50150CT -20 kPa (5. 50150T 50250F. use a 100 μm (150-mesh) tank filter on the suction side and install it more than 50 mm (2 in.150T. Double. please note that if any of the pumps listed in the Table 3 is started at low speed. When phosphate ester type fluid is used. 150T.9 in. Alignment of shaft Employ a flexible coupling whenever possible. Carry out sufficient contamination control for hydraulic fluids and keep contamination level within NAS class 12. Suction Pressure Minimum Model Numbers Petroleum base oil Single Pumps Double Pumps Combination Pumps 50T. Consult your Yuken representative in advance. 250F -20 kPa (5.6 ft. use suction pipes having the sizes shown in the dimensional drawings. For details. Hg Vacuum) 5050ST. Hg Vacuum) Maximum +140 kPa (+20 PSIG) With some nominal displacement. At starting. Hg Vacuum) 5050T. or discharge air by slightly slackening the connection on the discharge side. the pump may have difficulty in sucking up the fluid. at the pump inlet. 3. see the item of "Hydraulic Fluids".8 m (2. 5050ST 5050CT. If the pump is installed above the tank level. minimum suction pressures are limited because of pump speeds. In addition. 2. No.3 ft. For details. the maximum fluid viscosity is limited.9 in. Also. Combination VANE PUMPS Hydraulic Fluids / Instructions Hydraulic Fluids 1. Control of contamination Contamination of hydraulic fluids results in pump failures and reduced pump lives. Precautions at starting At an initial operation or at an operation after a long rest. For fluid viscosity at starting. catalogue No. 5050T. Type of hydraulic fluids Any hydraulic fluid listed in the table 1 below can be used.250F SERIES Fixed Displacement-Single. an air bleed valve should be installed beforehand on the discharge side (model No. Fluid viscosity and temperature Use the hydraulic fluids which satisfy the recommended viscosity and oil temperature given in the Table 2 below. Viscosity mm2/s (SSU) 600 100 (455) 950 200 (910) 3. However. the specifications of the pumps such as maximum pump speed may be changed according to the type of hydraulic fluids to be used. Hg Vacuum) 150150T.50T.0 m (3. 50150ST 5050CT. Instructions 1. Hydraulic fluids Type of Fluids Petroleum Base Oils Synthetic Fluids Water Containing Fluids (Table 1) Descriptions Use anti-wear type oils or R & O (Rust and Oxidation inhibitor) type oils (equivalent to ISO VG32 or 46).).9 in.9 in. 2.2 . 50150ST 50150CT Start-up Speed r/min Max. ) Foot Mtg.0 ( 2.9 ( 1...415) 11.9 ( 8.580) 36..73) 74. American Design Standard No.71) 115.6 ( 5.91) 61. . Refer to Pages 8 & 9.250F SERIES Fixed Displacement-Single 50T / 150T / 205F VANE PUMPS Specifications / Model Number Designation B Yuken can offer a large volume pump described below.. 200 F: Flange Mtg.3 .3) 25 (55..73) 201.5 (23. the maximum speed is restricted to 1200 r/min. .. Consult Yuken for details. -7 48. If phosphate ester type fluids are used.05) 133..50T.. 116 134. .9 ( 1. 75. 2000 7 (1020) 7 (1020) Refer to Pages 7 & 8. 153.1 ( 3. Mass kg (lbs. 94.GPM) Shaft Speed Range r /min 600-1200 Specifications Model Numbers Geometric Displacement cm3 /rev (cu.8) 600 26 (57. .8 (10..0 (12.6 ( 7. 10.5 ( 1.. Consult Yuken for the details.708) 16. Available to supply pump with anti-clockwise rotation.27) Maximum Operating Pressure MPa (PSI) 1 Shaft Speed Range r/min Output Flow & Input Power Max.57) 93. Design Standards: None. The maximum operating pressure is constant irrespective of fluid types. 176. Model Numbers 500F-∗-∗-RL-20/2080/2090 Max Operating Pressure MPa (PSI) 7 (1020) Output flow at 7 MPa (1020 PSI) and 1200 r /min with 20 mm2 /s (100SSU) fluid 324-530 (85.397) 25.1) 600 120 (265) 113 (249) 2 1200 7 (1020) Refer to Page 10. 1200 1.6 ( . .6-140. 23.0) L /min (U.. 1800 1500 2 Min...20) 47. N. European Design Standard 90 . (Viewed from Shaft End) R: Clockwise 1 (Normal) L: On Left Hand (Normal) 30 40 Refer to 2 40 1.007) 22.S.. 800 2 600 Approx.in /rev) 50T-7 50T-12 50T-17 50T-23 50T-26 50T-36 150T-48 150T-61 150T-75 150T-94 150T-116 250F-134 250F-153 250F-176 250F-200 6. 2.8 ( ..2) 9. ... Model Number Designation F50T Special Seals F: For phosphate ester type fluids (Omit if not required) Series Number 50T (Threaded Connections) 150T (Threaded Connections) 250F (Flanged Connections) -L -R L -30 ∗ Nominal Displacement cm3/rev Mounitng Direction of Rotation Discharge Port Position Design Number Design Standard 7.. 36 L: Foot Mtg. 61.. 26. ...150T. Flange Mtg..34) 175..9 ( 4. . 17. Japanese Standard "JIS" 80 .1 ( 9. 12.7 ( 2..17) 153. 2.0 (19. 13) (1.4 L "n" Dia.200(3.43) Dia. Rc 1 Rc 3/4 50T-∗-L-RL-3080 1 BSP.000) (2.7 50T-∗-L-RL-3090 (5.12) (2.97) (.43) Dia.849) 21.59) . (4.72)Sq.5 75 15 (5.91) (4.1969) 4.09) (1.41) (2.94) Dia.8 50 132. 11(.21) (2.250F Series Single Pump-Type "50T" VANE PUMPS Installation Drawing Foot Mtg.19) (. b e R15(R.5 (7.8661) 21.76) K T L H W 2 (.6 12.".570(.780) 95.849(.50) DIMENSIONS IN MILLIMETRES (INCHES) Flange Mtg.8 12.431(.742(.F 3/4 BSP.F 3/4 NPT 50T-∗-L-RL-3090 1 NPT Model Numbers 50T-∗-L-RL-30 Q C D F Dimensions mm (Inches) H J K N P 5.000(.000(.283) (2. Through 4 Places 11(.95) (1.10) (3.150T.1874) 4.3 69.746) For other dimensions.54) (1.760(.51) (2.92) F "N" Dia.565(3.000(.75) (. IN OUT Discharge Port "B" Thd.95) (4.7 4.08) 11(. refer to "Foot Mtg.76) 70 (2.7429) 21.20) 96. D 70 (2. j n 90 (3. E S S J Q Model Numbers 50T-∗-L-RL-30 "A" Thd.97) (5.000(3.72)Sq. d f 120(4.95) (.14) (3.91) (2.8 29 97 50.000) (1.7500) 19.543) 127 (5. Spotface 4 Places V U P 125 Dia.59) Model Numbers 50T-∗-F-RL-30 a b d Dimensions mm (Inchs) e f h 54 50 15 5 201 (7.000) (3.50T.94) (2. "B" Thd.50) (.7 50T-∗-F-RL-3090 (7.:50T-∗-F-RL-30/3080/3090 Design 30 a Design 3080/3090 120(4.1867) 202 104.59) 50T-∗-L-RL-3080 130 50.8653) 24.748) 95.8 82.8 50.13) (1. No.56) (5.029(.:50T-∗-L-RL-30/3080/3090 "C" Key Width Suction Port "A" Thd.969) (1.979(.1957) 201 104 28 90 50 50 78 (7.19) 95.939) 4.050(. Through 24(.165(3. Through 4 Places j j "h" Dia.43) Dia.3 55.07) 22.969) (3.778) 50T-∗-F-RL-3080 202 49.82) (2.59) (.945) 23.25) 19.844) Dimensions mm (Inches) S T U V E W 140 58 65 137.970(.000) R15(R. 379 ( .760(.99) 17.250) 158.250F Series Single Pump-Type "150T" VANE PUMPS Installation Drawing B Foot Mtg. D Dimensions mm (Inches) N P L 66 (2.488) 38 (1.98) 158.742(.000) DIMENSIONS IN MILLIMETRES (INCHES) Flange Mtg.000 (6. "h" Dia.26) 53 (2.1811) 29.34) 101. IN OUT Discharge Port "B" Thd.33) (2.69) (.5 187.06) 160.F 1-1/2 NPT 1-1/4 BSP.35) (2.69) F 100 (3.29) (2.299) 32.674 (6.5 58.1874) 4.5 (4.00) 16 6.299) 159.874) 186.35) 101.63) (.221 (1.1867) K 3 (.".247) 17.150T.5 187 (.000(.843 (1. No.400 (1.979 (1.86) 98.F 1-1/4 NPT 4. Through 28(1.996) 222 (8.12) 13.7 (2. "A" Thd.8 (9.:150T-∗-L-RL-40/4080/4090 "C" Key Width Suction Port "A" Thd.5 (9. a Model Numbers a b d Dimensions mm (Inches) e f g h n t 150T-∗-F-RL-40 237 58 50.5(.03) "t" Dia.072) H J 32 (1.400 (1.69) (7.4 (3.29) Rc 1-1/2 Rc 1-3/4 7.2 50.50) 54 (2.500) Q S T 226 (8.1803) 33.878) 186. Dimensions mm (Inches) E F C D 237 (9.36) 150T-∗-F-RL-4080 150T-∗-F-RL-4090 237.2756) 6.10) Dia.079) 27.3 (4.293) 66.91) Q P "B" Thd.964(.297) 13.51) Model Numbers 100 (3. "g" Dia.6 (7. refer to "Foot Mtg.35) 109 (4.5 (9.27) 237.960 (6.20) (9. 150T-∗-L-RL-40 150T-∗-L-RL-4080 150T-∗-L-RL-4090 Model Numbers 150T-∗-L-RL-40 150T-∗-L-RL-4080 150T-∗-L-RL-4090 K Q H 16 (.0000) 25.5 5 230 (.28) (1.000 (1.60) 30.09) 114 (4.5 . Through 6 Places 204 (8.4 228 (.5 (3.5 (7.94) N E "L" Dia. Spotface 4 Places J 140 (5.5 (3.3 (.33) 108.:150T-∗-F-RL-40/4080/4090 b e d f "n" Dia.74) 98.53) (7.000 (1.37) For other dimensions.63) 25.94) S 170 Dia. (6.25) (8.63) T 150 (5.6 (4.9992) 27.53) Dia.750 (6.50T.2742) 1-1/2 BSP.18) 114. "a" Thd.50) For other dimensions.85) Dia.024) 279. (14.14) 5/8-11 UNC 25 ( .5 (.F 2 NPT 1-1/2 BSP.900 (2.022) 318 (12.7 (5.01) 130 (5.) (1.999) 279.370 (10.72) Sq.31) 21.94) L Q P 100 Sq.5(.52) 250F-∗-F-RL-4080 250F-∗-F-RL-4090 279.9988) Dimensions mm (Inches) L N 250F-∗-L-RL-40 53.25) K K 330(12.48) F 108 (4.9675) P Q 305 (12. (3. 4 Places (2.87) For Reference: Dimensions of Pipe Flange Mounting Surface Suction Port Discharge Port 190 (7.5 (6.21) 108(4.800 (2.150T.75) 29.5 (12.8 (7.87) "C" Key Width Suction Port "A" Thd.69) 28 (1. No.17) (5. Dia.12) 39(1. "b" Deep 73 73 "a" Thd.5 (1.54) 100 Sq. Through 6 Places "b" Dia.9685) 49.078) 140 (5.087) 52.01) 170 (6.500) 6.957 (.97) Discharge Port "B" Thd.45) "H" Dia.000 (.512) 5 (.06) b mm (IN. (3. (1.16) DIMENSIONS IN MILLIMETRES (INCHES) Flange Mtg.250F Series Single Pump-Type "250F" VANE PUMPS Installation Drawing Foot Mtg.:250F-∗-L-RL-40/4080/4090 73 (2.151) 139.69) Dia.0000) 50. 113(4.4989) Model Numbers J K Dimensions mm (Inches) E F 85 (3.290 (10.26) H 50. Model Numbers "a" Dia.673 (.99) Model Numbers "A" Thd.000 (11.46) 73 (2.3 (3.44) 177.700 (.:250F-∗-F-RL-40/4080/4090 425(16.02) 32 (1.07) 171.24) 87. Through 43(1.35) 180 (7. 250F-∗-L-RL-40 250F-∗-L-RL-4080 250F-∗-L-RL-4090 "B" Thd.5000) 12.57) 4 Places 120(4. Spotface 4 Places E 230 (9.94) 21(.73) 215 (8.6 Dimensions mm (Inches) a b .4707) 2 BSP.73) 107(4.4 (5.F 1-1/2 NPT 12.000) 133. refer to "Foot Mtg. 250F-∗-∗-RL-40 250F-∗-∗-RL-4080 250F-∗-∗-RL-4090 51 (2.20) 250F-∗-L-RL-4080 250F-∗-L-RL-4090 54.25) 8 (.50T.4724) 11.000 (1.98) 55 130 (2.87) 40 50 "b" Deep Dia.996) 317. 356 Dia.5 (12. (1.38) "J" 240 Dia.087) 133 (5.87) (2.161) 54.45) Sq.640 (2.12) 35 M 16 29 (1.25) 50.948 (11. (9.26) 250F-∗-F-RL-40 280. Model Numbers N IN OUT 425(16.". D "a" Thd. C D Rc 2 Rc 1-1/2 12.770 (1.85) Dia.785 (2.000 (2.10) 306.975 (1. S.S.7 .150T.GPM 10 HP 6 Input Power Output Flow U.GPM 8 50T-12 MPa 1000 PSI 0 0 0 0 1 200 2 3 400 4 600 5 6 800 7 0 MPa 1000 PSI Pressure No.250F Series Single Pump-Type "50T" VANE PUMPS Typical Pump Characteristics B Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils. 50°C (122°F)] 50T-7 6 20 2000 r /min 1800 r /min 1500 r /min 6 1000 r /min 4 L /min 30 10 2 20 4 1200 r /min 1000 r /min 10 2 kW 0 kW 3 3 2 1 1 0 0 1 2 3 200 4 5 400 600 Pressure 6 800 7 4 0 4 2 0 0 HP 3 Input Power 0 0 MPa 0 1000 PSI 0 2 200 3 4 5 400 600 Pressure 6 800 7 0 0 MPa 1000 PSI L /min 50 1800 r /min 1800 r /min 40 Output Flow 10 1500 r /min 1200 r /min 20 kW 5 1000 r /min 4 HP 6 1500 r /min 8 4 10 30 kW 4 2 2 6 4 4 2 0 200 2 3 400 4 600 Pressure 5 6 800 7 2 1 0 1 4 3 1 0 8 5 1000 r /min 20 3 HP 6 1200 r /min 6 Input Power Output Flow U.GPM 12 6 2 1 50T-23 40 30 2 1 50T-17 8 4 2 L /min U.50T.S.S.GPM 8 2000 r /min 1800 r /min 1500 r /min 1200 r /min Input Power L /min 30 Output Flow U. GPM L /min 65 17 Input Power U.S.8 6 4 L /min U.S.GPM L /min 50 13 .GPM 100 26 24 0 4 150T-61 70 0 8 0 0 12 10 10 6 2 Output Flow Output Flow 18 HP 12 8 30 150T-48 L /min U.250F Series Single Pump-Type "50T"&"150T" VANE PUMPS Typical Pump Characteristics Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.150T.S.S.GPM 80 20 kW 10 5 12 8 4 0 0 0 1 200 2 3 4 400 600 Pressure 5 6 800 7 MPa 1000 PSI 0 Input Power 0 1800 r /min 60 40 Input Power Output Flow 40 10 8 U. 50°C (122°F)] 50T-26 50T-36 1800 r /min 12 16 Output Flow 1500 r /min 1200 r /min 30 1000 r /min kW 6 20 4 0 200 4 5 400 600 Pressure 6 800 1200 r /min 6 8 8 6 2 0 3 12 8 2 2 50 10 4 1 7 1500 r /min 14 HP 10 4 1000 r /min 16 14 MPa 0 1000 PSI 0 1 3 2 200 1500 r /min 60 1200 r /min 50 1000 r /min 40 22 2 4 5 400 600 Pressure 6 800 7 0 MPa 1000 PSI 5 18 200 2 3 4 400 600 Pressure 5 6 800 7 12 8 0 0 MPa 1000 PSI 1200 r /min 70 1000 r /min 60 14 50 HP 16 4 1 80 kW HP 15 20 16 10 Input Power 10 1500 r /min 90 20 16 kW 15 No.50T. 150T. 50°C (122°F)] 150T-75 L /min 120 U.250F Series Single Pump-Type "150T" VANE PUMPS Typical Pump Characteristics B Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.S.9 .GPM 30 150T-94 0 0 MPa 1000 PSI Pressure 150T-116 34 130 32 120 1200 r /min 1000 r /min 30 110 28 26 kW 20 100 24 15 HP 24 20 16 10 5 0 0 1 200 2 3 4 400 600 Pressure 5 6 800 12 8 Input Power Output Flow U.50T.GPM 30 1500 r /min 110 24 22 100 1200 r /min 90 18 16 26 1000 r /min 70 kW 15 60 10 12 8 4 0 0 2 200 3 4 400 5 6 600 800 7 80 kW 15 20 5 1 90 HP 16 0 100 1000 r /min 24 22 80 20 1200 r /min 110 28 10 5 12 8 4 0 MPa 0 1000 PSI 0 Pressure HP 20 16 Input Power Output Flow 26 Output Flow 28 L /min 120 1 200 2 3 400 4 600 5 6 800 7 Input Power U.GPM L /min 37 140 36 4 0 0 7 MPa 1000 PSI No.S.S. S.10 5 6 800 0 7 MPa 15 10 1000 PSI 40 35 25 20 15 10 5 5 0 HP 45 30 20 10 5 0 1000 PSI 1200 r /min Input Power 20 2 0 L /min 260 30 1 5 250F-200 U.250F Series Single Pump-Type "250F" VANE PUMPS Typical Pump Characteristics Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.GPM 200 50 180 45 160 40 140 35 120 30 .50T.S.GPM L /min 60 220 Output Flow 4 0 7 MPa Pressure Pressure 0 20 15 0 0 1 2 200 3 400 4 5 600 Pressure 6 800 0 7 MPa 1000 PSI 5 0 Input Power 0 5 5 0 7 MPa 25 10 10 5 HP 35 Input Power L /min U.150T.GPM 65 1200 r /min 55 Output Flow 200 50 180 1000 r /min 45 160 40 kW 30 140 25 60 240 15 10 220 kW 35 55 200 1000 r /min 50 HP 40 180 30 45 35 160 25 25 20 15 200 3 400 4 600 Pressure No.S.S. 50°C (122°F)] 250F-134 250F-153 U.GPM 50 L /min 200 Output Flow Output Flow 180 1200 r /min 1000 r /min 100 160 40 1000 r /min 140 35 30 HP 35 kW 25 1200 r /min 45 120 kW 25 100 30 30 20 20 Input Power 25 15 20 15 10 15 10 1 0 2 3 200 5 4 400 600 6 800 0 0 1 0 1000 PSI 2 200 3 400 250F-176 5 6 600 800 U. 2.50T.150T. CAUTION When making replacement of seals. Seal kits consist of 11 (oil seal) and 14 and 15 and 23 (o-rings). seals are diferent from the above.11 . Seal kits consist of 11 (oil seal) and 14 and 15 (o-rings). For pumps for phosphate ester type hydraulic fluids. 2 23 O-Ring 13 Bearing 12 Bearing Seal Kit Numbers SO-NB-G60 6309 6305 KS-250F-40 2. seals are diferent from the above. beanings or cartridge kits. please do it carefully after reading through the relevant instructions in the Operator's Manual."150T"&"250F" VANE PUMPS Spare Parts List 50T-∗-∗-RL-30/3080/3090 150T-∗-∗-RL-40/4080/4090 4 16 15 5 1 19 12 14 17 8 A 13 B 11 6 18 3 9 2 A Section A-A Item & Name Model Numbers 50T-7-∗-RL-30∗ 50T-12-∗-RL-30∗ 50T-17-∗-RL-30∗ 50T-23-∗-RL-30∗ 50T-26-∗-RL-30∗ 50T-36-∗-RL-30∗ 150T-48-∗-RL-40∗ 150T-61-∗-RL-40∗ 150T-75-∗-RL-40∗ 150T-94-∗-RL-40∗ 150T-116-∗-RL40∗ 5 Cartridge Kit C50-7-30 C50-12-30 C50-17-30 C50-23-30 C50-26-30 C50-36-30 C150-48-40 C150-61-40 C150-75-40 C150-94-40 C150-116-40 2 11 Oil Seal 14 O-Ring 15 O-Ring 12 Bearing 13 Bearing Seal Kit Numbers ISPD25388 SO-NA-P41 SO-NA-A234 6204 6200 KS-50T-30 ISPD32427 SO-NA-P46 SO-NA-A248 6205 6203 KS-150T-40 1. No.250F Series Single Pump-Type "50T". Please contact us. Please contact us. For pumps for phosphate ester type hydraulic fluids. 250F-∗-∗-RL-40/4080/4090 24 21 23 23 22 24 9 18 12 16 4 15 5 1 19 13 14 6 17 20 A 8 11 3 2 A Section A-A Item & Name Model Numbers 250F-134-∗-RL-40∗ 250F-153-∗-RL-40∗ 250F-176-∗-RL-40∗ 250F-200-∗-RL-40∗ 5 Cartridge Kit C250-134-40 C250-153-40 C250-176-40 C250-200-40 11 Oil Seal 14 O-Ring 15 O-Ring ISPD527512 SO-NA-G95 SO-NB-G165 1. Same as Single Pump "50T" (Refer to pages 7 & 8) Same as Single Pump "50T" (Refer to pages 7 & 8) 2000 Same as Single Pump "50T" (Refer to pages 7 & 8) Same as Single Pump "150T" (Refer to pages 8 & 9) 1200 Same as Single Pump "150T" (Refer to pages 8 & 9) Same as Single Pump "150T" (Refer to pages 8 & 9) Same as Single Pump "50T" (Refer to pages 7 & 8) Same as Single Pump "150T" (Refer to pages 8 & 9) Model Number Designation F5050T -7 Series Number 5050T (Threaded Connections) F: 50150T For phosphate (Threaded Connections) ester type 150150T fluids (Omit if (Threaded Connections) not 50250F required) (Flange Connections) 150250F (Flange Connections) Min. . . . .. . the maximum pump speed is restricted as follows: ND..250F SERIES Fixed Displacement-Double. 17.12 Approx. 26. If nominal displacement 7 is used on the pump on smallvolume side. (For other models.. . 23.. .150150T. 116 7. 12. . restrict it to -20 kPa (5. 94. 36 48. 4 31 (68.. . 75.. Hg. 200 1. . .. European Design Standard 90 .) Foot Mtg.. 40 (Viewed from Shaft End) 7. . -12 -L Small Volume Pump Large Volume Pump Nominal Displacement Nominal Displacement Mounting cm3/rev cm3/rev -R Direction of Rotation L -40 Discharge Design Port Position Number 7.50250F..150T.8-70) r /min 600-1200 Specifications Model Numbers Max. 94. . 23. If nominal displacement 94 or 116 is used. 12. Consult Yuken for details.50T... 61. 26 or 36 is used.. 17. Available to supply pump with anti-clockwise rotation. .23 . . .. 1500 r /min 36 .... 61. R: L: Clockwise 1 On Left Hand (Normal) (Normal) F: Flange Mtg.. . 17. 26. 61. If large-volume side nominal displacement 94 or 116 is used at a speed above 1000 r/min. . Small Volume Pump 1. restrict the suction pressure to -7 kPa (1.Japanese Standard "JIS" 80 . 131 (289) 125 (276) Same as Single Pump "250F" (Refer to page 10) 1200 600 146 (322) 140 (309) Large Volume Pump Max. . Vacuum)..4) 29 (63.) Special Seals Shaft Speed Range r /min Output Flow & Input Power L: Foot Mtg.. the maximum speed is restricted to 1200 r/min. . 94. 17. 75. Hg Vacuume. . 12. 26. American Design Standard .. 23. If nominal displacement 17. . Design Standards: None.. The maximum operating pressure is constant irrespective of fluid types. 75. 94. 2 6 600 3 5 6 4 4... 5050T.. the minimum speed is restricted to 800 r/min... .. 61. 17. 153. 116 48..50150T...GPM) (100 SSU)fluid Shaft Speed Range (Each Pump) 162-265 (42. 36 134. 1800 r /min 26 .... . 116 48..150250F VANE PUMPS Specifications / Model Number Designation Yuken can offer a large volume double pump described below. 12. 5. 116 134. . .. . 36 ∗ Design Std. 176. MPa (PSI) 7 (1020) Output flow at 7 MPa (1020 PSI) L /min and 1200 r /min with 20 mm2 /s (U. 23. the maximum speed is restricted to 1200 r/min... 200 48. Consult Yuken for the details. N. 6.97 in. . 26.. 23. 176.9) 4 600 60 (132) 55 (121) 1500 600 67 (148) 62 (137) Same as Single Pump "250F" (Refer to page 10) 1200 600. Operating Pressure MPa (PSI) 5050T 7 (1020) 50150T 7 (1020) 150150T 7 (1020) 50250F 7 (1020) 150250F 7 (1020) 1 1 1 1 1 Flange Mtg. 250250F-∗-∗-∗-RL-20/2080/2090 Model Numbers Max Operating Pres.S. Mass kg (1bs. 40 20 Refer to 2 40 40 2. 2. If phosphate ester type fluids are used. 153. . No. . . 1200 r /min 3. 36 7. 75...9 in... 72) Large Volume Pump Discharge Port "B" Thd.247) (7.69) Dia.10) Dia.06) Dia.191 (1.299) 190 6 (.071) (3.743 (1.24) 159.349 (. 162(6.27) "B" Thd.74) (.13 .370 (.80) DIMENSIONS IN MILLIMETRES (INCHES) Flange Mtg.38) L D 120 (4.36) 232(9.9843) 28.25 20. Small Volume Pump Discharge Port "B" Thd.078) 88.57) (3.9988) 27.59) (3.51) 105 (4.94) J K 3 (.15) IN P1 "C" Key Width Foot Mtg.9 167.F 3/4 NPT 4.53) Dia.:5050T-∗-∗-F-RL-40/4080/4090 "b" Dia.150T.5(.298) (7. C D Dimensions mm (Inches) E F H J K L Rc 3/4 7.9980) 27.38) 51 (2.1874) 50.250F Series Double Pump-Type "5050T" VANE PUMPS Installation Drawing B Suction Port "A" Thd.730 (.94) 80 (3.960 (6.13) 5050T-∗-∗-L-RLRc 1-1/2 40 5050T-∗-∗-L-RL-4080 1-1/2 BSP.26) 158.F 5050T-∗-∗-L-RL-4090 1-1/2 NPT 20(.760 (. 314(12. 230(9.674 (6.000 (6.8 25.37) For other dimensions.5(.89) (2.5 158.50T.3 95. Model Numbers 13.543) (6.1862) (2.000 (1.79) 3/4 BSP.2756) 50 25. Through 28(1.964 (.000 (.01) H 210(8.12) 35(1.370 (1.750 (6. No.250) 187.36) 57 175 (6. Model Numbers 17.979 (.500) (6. "A" Thd.000 (.:5050T-∗-∗-L-RL-40/4080/4090 P2 314(12.13) a 16 (.26) "E" Dia.76) 100 (3.". Through 6 Places "d" Dia.9834) 24.79) H 100 (3. 197(7.092) (3.000) 25.24) 140 (5.3 4.75) (. Spotface 4 Places F 127(5. refer to "Foot Mtg.102) 90 167 95 20 6.00) Dia.2742) (2.48) 5050T-∗-∗-F-RL-4080 5050T-∗-∗-F-RL-4090 6.63) Dimensions mm (Inches) a b d 5050T-∗-∗-F-RL-40 160.3 (.008) 24. 32 (1. 01) (.7 25.225 (1. F 165(6. Model Numbers 32 (1. refer to "Foot Mtg. 280(11.50T. Spotface 4 Places 300(11.647) (8.525 (.5 38.975 (1.26) For other dimensions.31) 105 (4.86) (6.3923) (1.02) Dia.:50150T-∗-∗-L-RL-40/4080/4090 Suction Port "A" Thd.13) IN P1 P2 388(15.69) Dia.656) (8.990) (9.5 50150T-∗-∗-F-RL-4090 (8.F 50150T-∗-∗-L-RL-4090 2 NPT 1-1/4 NPT 3/4 NPT N 50(1.20) 203. d f Dimensions mm (Inches) e f g 225 175 120 75 22 (8.3750) (2.69) (2.000) 241. P "H" Dia.4961) 42.15) DIMENSIONS IN MILLIMETRES (INCHES) Flange Mtg.72) (2. 195(7.49) 50150T-∗-∗-F-RL-4080 224 174 119 76 21 6. D E E L K Large Volume Pump Discharge Port "B" Thd. Through 35(1.000 (7.839 (1.87) h n 5 (. "D" Key Width 250(9.24) (2.662) 220.76) Dimensions mm (Inches) H J K L N P 10.997) (9.69) Dia.83) (.82) (6.85) (4.150T.4990) 42.000 (1.050 (1.4980) 42.075 (1.91) 30(1.3937) 50 64 38.3760) 57 63.84) 135 (5.626) 275(10.5 117. "B" Thd. Small Volume Pump Discharge Port "C" Thd.26) J 127(5.7 9.5 120.50) 50150T-∗-∗-L-RLRc 3/4 Rc 2 Rc 1-1/4 40 50150T-∗-∗-L-RL-4080 2 BSP.72) (.954 (7.F 3/4 BSP.7 3.F 1-1/4 BSP.:50150T-∗-∗-F-RL-40/4080/4090 388(15.12) 9.550 (.75) (1. 203.81) "A" Thd.66) (4.18) 117.68) (4.3 203.250F Series Double Pump-Type "50150T" VANE PUMPS Installation Drawing Foot Mtg.000 (.28) 17.000 (1.5(.68) 70 (2.95) (.50) .5 (4.28) a b e g "h" Dia.626) (4.97) 150(5.5(.964 (.99) (.".98) (.38) Dia.200 (8.075 (1.97) (2.128 (7.89) (4.14 a b d "n" Dia.4951) 41. Through 6 Places Model Numbers 50150T-∗-∗-F-RL-40 No.520) 37.654) 220 120 25 3 9.00) Dia.992) 241 202.83) "C" Thd.500) 38. 17. 91) 117.525 (.68) (4.5(18.".954 (7.02) Dia.4990) 42.69) Dia.150T.69) Dia.26) 203.15) DIMENSIONS IN MILLIMETRES (INCHES) Flange Mtg.3923) (2.000 (1.17) (2.225 (1.20) (2. "C" Key Width Large Volume Pump Suction Port "A" Thd.09) E Dimensions mm (Inches) F H J K L N 10.94) IN IN 100 (3.5(.12) 150150T-∗-∗-L-RL-2080 1-1/2 BSP.38) Dia.66) (4.F 150150T-∗-∗-L-RL-2090 1-1/2 NPT 1-1/4 NPT 9.4951) 40.500) 38.50) C D K N L J "H" 161(6.685 (1.050 (1.000 (. 280(11.69) Dia.50T.7 25.98) (.39) 75 (2.83) 30(1.34) 70 (2.5 117.975 (1.95) 22 (. 459.250F Series Double Pump-Type "150150T" VANE PUMPS Installation Drawing B Foot Mtg.990) g 241 (9.75) (1.94) Small Volume Pump Suction Port "A" Thd.656) (8. OUT OUT Small Volume Pump Discharge Port "B" Thd.87) 5 (.5 (.964 (. Rc 1-1/2 Rc 1-1/4 150 (5.075 (1.49) 150150T-∗-∗-F-RL-2080 203.992) 86 (3.000 (7.3 (9.662) 220.3937) 56 64 38.075 (1.97) E Model Numbers 150150T-∗-∗-L-RL-20 "A" Thd.5(18. Through 35(1.50) 85 (3.20) 202.5(.69) Dimensions mm (Inches) d e f 203. 17. "B" Thd.5 38.626) 275(10. a d "f" Dia.5 (4.69) "F" Dia.128 (7.:150150T-∗-∗-F-RL-20/2080/2090 459.200 (8.99) 21 (.4980) 42.3750) (2. No.F 1-1/4 BSP.000 (1.7 3. Through 6 Places Model Numbers 150150T-∗-∗-F-RL-20 a b "g" Dia.68) Dia.4961) 41. 195(7.35) 76 (2.997) 150150T-∗-∗-F-RL-2090 For other dimensions.614) 220 120 25 3 9.72) (.626) (4.5 120. 170(6. 170(6.520) 37.76) D 170(6.15 .000) 241.3760) 55 63.83) 6.09) b e 17.550 (. refer to "Foot Mtg.01) (.18) 165(6.602) (8. Large Volume Pump Discharge Port "B" Thd.:150150T-∗-∗-L-RL-20/2080/2090 100 (3. Spotface 4 Places 50(1.7 9. 48) DD 108 (4.9675) 52. No. F 190(7.75) (1.685 (2.000 (2.3 177.84) (12.54) 100(3.9988) 54.5(.4989) (3.52) 150250F-∗-∗-F-RL-4080 279.52) 620. "D" Thd.700 (.250F Series Double Pump-Type "50250F"&"150250F" VANE PUMPS Installation Drawing Foot Mtg.512) (12.F 150250F-∗-∗-L-RL-4090 2 NPT Model Numbers AA 50250F/150250F-∗-∗-L-RL-40 "B" Thd.957 (.26) e "a" Dia.5 50250F/150250F-∗-∗-L-RL-4090 12.85) Dia.900 (2. "J" Dia.: 50150F-∗-∗-F-RL-40/4080/4090 150250F-∗-∗-F-RL-40/4080/4090 d 107 (4. Dimensions mm (Inches) b d e 50250F-∗-∗-F-RL-40 280.38) 39(1.000 (11.9685) 53.022) 318 (12.25) 50.150T.F 3/4 NPT Rc 1-1/4 1-1/4 BSP. Through 43(1. See page 6.024) 279.12) 55 (2.5 (24.16 a 318 (12.94) 620. E E IN OUT OUT Small Volume Pump Discharge Port "D" Thd.7 306.640 (2.5 277 317.5 29.000 (11.5000) 87.5 171.94) Sq.0000) 54.F 1-1/2 NPT Rc 1-1/2 1-1/2 BSP.800 (2. 21. Suction Port "C" Thd.20) 50250F/150250F-∗-∗-L-RL-4080 12.996) 562 250 317.31) 108 (4.01) CC 230 (9. "C" Thd.975 (1.91) (12. 8 (.290 (10.770 (1.F 2 NPT 50250F-∗-∗-L-RL-4090 Rc 2 150250F-∗-∗-L-RL-40 150250F-∗-∗-L-RL-4080 2 BSP.91) 170 (6.024) 279.06) 130 (5.24) 49.948 (11.12) 130 (5.50) 150250F-∗-∗-F-RL-40 280.35) (7.21) 32(1. KK 35(1.25) Model Numbers 21.999) 150250F-∗-∗-F-RL-4090 279.".151) (5.13) 250 (9. "AA" Key Width IN Large Volume Pump Suction Port Small Volume Pump "A" Thd. BB FF 215 (8.25) HH HH 330(12.92) 100 (3. Large Volume Pump Discharge Port "B" Thd.07) (6.000 (. refer to "Foot Mtg.45) Dia.370 (10. Through 6 Places "b" Dia.01) (6.4 50.44) (7.022) 50250F-∗-∗-F-RL-4080 50250F-∗-∗-F-RL-4090 279.290 (10.999) 279. Spotface 4 Places 51 (2.5 (22. Model Numbers Rc 2 50250F-∗-∗-L-RL-40 50250F-∗-∗-L-RL-4080 2 BSP.16) (.5(.26) DIMENSIONS IN MILLIMETRES (INCHES) Flange Mtg.50T. Rc 1-1/2 1-1/2 BSP.76) 562 (22.370 (10. 356(14.000) (5.69) HH JJ Dimensions mm (Inches) EE FF KK LL NN 12.17) NN JJ LL 100(3.99) "A" Thd.43) 277 (10.F 1-1/2 NPT Rc 3/4 3/4 BSP.074) (5.F 1 NPT Rc 1-1/2 1-1/2 BSP.4724) 85 180 133 50.94) Sq.46) H "EE" Dia.F 1-1/4 NPT BB CC DD E Dimensions mm (Inches) F H J 70 (2.673 (.000 (1.5 6.500) (12.23) (10.69) (1.161) 139.85) Dia. 240(9.F 1-1/2 NPT Rc 1 1 BSP.996) For other dimensions.5 (24.4708) (3.02) Dia.948 (11.10) (.69) Dia.087) (5.: 50150F-∗-∗-L-RL-40/4080/4090 150250F-∗-∗-L-RL-40/4080/4090 The dimensions of the pipe flange mounting surface for suction and discharge ports are the same as those of "250F" series single pumps.50) .087) 140 305 170 28 5 11.8 133.84) 125 (4.13) (9. 50150T. When ordering seals. 2) Cartridge kits are common with 150T series single pumps.-40 C150.-40 Notes:1) and are spaces for nominal displacement figures. seals are different from the above. please specify the seal kit number from the table in the following page. When ordering seals.150T. see page 11.-30 C150. 1 2 3 1 1 Note: For pumps for phosphate ester type fluids. 2) Cartridge kits are common with 50T or 150T series single pumps.250F Series Double Pump-Type "5050T". please specify the seal kit number from the table in the following page.VANE PUMPS 50T. 150150T-∗-∗-∗-RL-20/2080/2090 16 Model Numbers 17 10 7 19 15 4 18 A 20 21 14 3 11 9 12 15 8 A 5 Seals & Bearings Item 10 11 12 13 14 Name of Parts Oil Seal O-Ring O-Ring Bearing Bearing Section A-A Cartridge Kits Part Numbers ISPD 406212 SO-NA-A248 SO-NA-G90 6207 6203 Qty.- Cartridge Kit Numbers 7 8 Large Volume Small Volume Pump Pump C50C50- -30 -30 C50. Model Numbers 150150T- - Cartridge Kit Numbers 8 9 Large Volume Small Volume Pump Pump C150. For details. 1 1 2 1 1 1 1 Note: For pumps for phosphate ester type fluids. Please contact us."50150T"&"150150T" Spare Parts List B 5050T-∗-∗-∗-RL-40/4080/4090 50150T-∗-∗-∗-RL-40/4080/4090 20 4 19 A 11 15 21 10 5 22 24 6 25 23 16 3 14 8 2 17 12 9 A 1 7 13 Section A-A 18 Seals & Bearings Item Name of Parts 10 11 12 13 14 15 16 Oil Seal O-Ring O-Ring O-Ring O-Ring Bearing Bearing Cartridge Kits Part Numbers 5050T 50150T ISPD 406212 ISPD 325211 SO-NA-P62 SO-NA-P52 SO-NB-G45 SO-NB-G30 SO-NA-A248 SO-NA-A234 SO-NA-A234 SO-NA-A234 6207 6305 6200 6200 Qty. For details.-40 Notes:1) and are spaces for nominal displacement figures. No. 1 6 16 2 1 13 5050T. CAUTION When making replacement of seals. Please contact us. seals are different from the above. beanings or cartridge kits. see page 11.17 .please do it carefully after reading through the relevant instructions in the Operator's Manual. seals are different from the above. 3 15 20 23 27 21 7 2 18 9 A 10 16 28 4 8 30 13 31 5 24 6 12 A 25 Cartridge Kits Model Numbers 50250F. please specify the seal kit number from the table below. see page 11. When ordering seals. For details.-40 C250C250- -40 -40 Notes:1) and are spaces for nominal displacement figures.150T.50T. Please contact us. beanings or cartridge kits. 2) Cartridge kits are common with single pumps. please do it carefully after reading through the relevant instructions in the Operator's Manual. 1 1 1 2 2 1 1 1 Note: For pumps for phosphate ester type fluids.18 29 17 22 26 11 14 Section A-A 1 Seal Kit Numbers KS-5050T-40 KS-50150T-40 KS-150150T-20 KS-50250F-40 KS-150250F-40 . Seal Kit Numbers Model Numbers 5050T-∗-∗-∗-RL-40/4080/4090 50150T-∗-∗-∗-RL-40/4080/4090 150150T-∗-∗-∗-RL-20/2080/2090 50250F-∗-∗-∗-RL-40/4080/4090 150250F-∗-∗-∗-RL-40/4080/4090 No.- Cartridge Kit Numbers 9 10 Small Volume Large Volume Pump Pump C50.150250F.250F Series Double Pump-Type "50250F"&"150250F" VANE PUMPS Spare Parts List 50250F-∗-∗-∗-RL-40/4080/4090 150250F-∗-∗-∗-RL-40/4080/4090 23 19 15 CAUTION When making replacement of seals.-30 C150. Seals & Bearings Item Name of Parts 11 12 13 14 15 16 17 18 Oil Seal O-Ring O-Ring O-Ring O-Ring O-Ring Bearing Bearing Part Numbers 50250F 150250F ISPD 527512 ISPD 527512 SO-NB-G165 SO-NB-G165 SO-NA-G95 SO-NA-G95 SO-NB-G50 SO-NB-G90 SO-NB-G60 SO-NB-G60 SO-NA-A234 SO-NA-A248 6309 6309 6305 6305 Qty. . (Viewed from Shaft End) 40 R: Clockwise 1 (Normal) 40 L: On Left Hand (Noramal) ∗ Refer to 2 40 40 2... 12. ... Min. . 6. 2000 Same as Single Pump "50T" (Refer to pages 7 & 8) 1. 1500 r /min 36 . Threaded Connections 50150CT Relief-unloading Type. American Design Standard No.. 26.150T. 17.. ...6) 4 70 (154) 65 (143) 4 44 (97) 42 (92. .. The maximum operating pressure is constant irrespective of fluid types.. 26. 26 or 36 is used. restrict the suction pressure to -7 kPa (1. ..... Available to supply pump with anti-clockwise rotation.. Range Small Volume Large Volume of Unloading Direction of Pump Nominal Pump Nominal Mounting Valve Displacement Displacement Rotation MPa (PSI) cm3/rev cm3/rev 7. If nominal displacement 7 is used on the pump on smallvolume side... 26.0 . 12. 42 (92. (For other models.Mass kg (1bs. . 17 23.435) F: 3...145) E: 1.. 12. 36 48. .. Vacuum).19 B . 600 1200 Approx. . 36 48. If large-volume side nominal displacement 94 or 116 is used at a speed above 1000 r/min.9 in.0 .. .6) 3 600 4 70 (154) 65 (143) 4. Design Standards: None. . 2.. 61...1. . ... ..1020) L Discharge Port Position -40 Design Design Number Std. . If nominal displacement 17. N.. . Threaded Connections 5050CT Relief-unloading Type.. 75 94.0 (435 . ... F: Flange Mtg. 36 4 600 2000 Same as Single Pump "150T" (Refer to pages 8 & 9) Flange Mtg.) Foot Mtg.7.. Hg Vacuume. .23 .3. 116 44 (97) 600 1200 -R Pres.250F SERIES Fixed Displacement-Combination 5050ST/50150ST/5050CT/50150CT VANE PUMPS Specifications / Model Number Designation Specifications Pump Types Model Numbers Max. restrict to -20 kPa (5. .. the maximum speed is restricted to 1200 r/min.97 in. Threaded Connections F: For phosphate ester type fluids (Omit if not required) 50150ST Relief-relief Type.. . .0 (73 . 2 6 Same as Single Pump "150T" (Refer to pages 8 & 9) 3 2 6 7.) Model Number Designation F5050CT -7 Large Volume Pump Same as Single Pump "50T" (Refer to pages 7 & 8) 1 Reliefunloading Type Shart Speed Range r /min Output Flow & Input Power L: Foot Mtg.. Adj. the minimum speed is restricted to 800 r/min... . Hg. 17 23. . 12..50T. 61. .0 (145 .. . . 116 1. Operating Pressure MPa (PSI) 5050ST 7 (1020) 50150ST 7 (1020) 5050CT 7 (1020) 50150CT 7 (1020) Small Volume Pump 1 Reliefrelief Type 1 1 Same as Single Pump "50T" (Refer to pages 7 & 8) Same as Single Pump "50T" (Refer to pages 7 & 8) Special Seals Series Number 5050ST Relief-relief Type. . the maximum speed is restricted to 1200 r/min. -L -D 7. 26. the maximum pump speed is restricted as follows: ND. 1200 r /min 3. 1800 r /min 26 .. 36 7. If nominal displacement 94 or 116 is used. 17 23. Consult Yuken for details.5 . 23. Threaded Connections -12 Max. . 17 23. 75 94. . European Design Standard 90 . 5. D: 0.. . . If phosphate ester type fluids are used.Japanese Standard "JIS" 80 . 99) 5(.:5050ST-∗-∗-L-RL-40/4080/4090 100 (3.69) Dia.000 (.". "B" Thd.979 (.150T.15) "d" Dia. Rc 1-1/2 Rc 3/4 Rc 1/4 Rc 1/4 7.191 (1.092) 90 (3.01) INC.76) 16(.63) DIMENSIONS IN MILLIMETRES (INCHES) Model Numbers 5050ST-∗-∗-∗-RL-40 5050ST-∗-∗-∗-RL-4080 5050ST-∗-∗-∗-RL-4090 Model Numbers No.1862) 50.960 (6.75) a b d 20 (.964 (. 244.5(.79) K K 210(8.20) P1 8 (.31) 15 (. F 120 (4.24) 160.9980) E Dimensions mm (Inches) N P J K L 5050ST-∗-∗-∗-RL-40 28.9 (3.Tr 1/4 NPT 4. 98 (3.3 (6.2756) 6. "E" Key Width 314(12.9988) 25.79) 6 (.000 (6.76) I N 80 (3. Foot Mtg.349 (.760 (.94) 20(.5(7.102) 27.1874) 4. refer to "Foot Mtg.370 (1.53) Dia.F 1/4 NPT 1/4 BSP.50T.80) 6. Suction Port "A" Thd.72) 152.37) .76) 17.7 (.25 (3.500) 167.19) Large Volume Pump Relief Pressure Adjustment Handle Small Volume Pump Relief Pressure Adjustment Handle 51(2. L J P2 T 76 (2. Spotface 4 Places 187.370 (.000) 25.250) 158.06) Dia.5 (.86) Small Volume Pump Discharge Port "B" Thd.674 (6. Through 4 Places 57 a (2. Pres.50) 178(7.F 1-1/2 NPT 3/4 BSP.63) 197(7.9843) 24.27) Pressure Gauge Connection "D" Thd.36) 230(9.50) (4. Through 28(1.45) 13.9834) 1-1/2 BSP.3 (.3 (7.5(.26) INC.38) N P 3 (.10) Dia.543) 167 (3.20 Dimensions mm (Inches) F H "A" Thd.89) 131 (5.70) 35(1.F 3/4 NPT 1/4 BSP.15) Extended Vent Connection "C" Thd.008) 25.730 (.12) 5 (.59) 95.76) 38 (1.250F Series Combination Pump-Type "5050ST" VANE PUMPS Installation Drawing Flange Mtg. 70 (2.5(5. Tank Port "B" Thd. P1 P2 175(6.5 (6.2742) 50 (2.750 (6.01) 138.20) "H" Dia.00) 195.:5050ST-∗-∗-F-RL-40/4080/4090 Fully Extended 334(13.15) 121 38 (1.298) 190 (7. For other dimensions.5(3.5(7. Gauge Connection "D" Thd.543) 95 (3. "D" Thd.26) 158.299) 159. Large Volume Pump Discharge Port "B" Thd.59) "4080" Design Only 32(1.071) 88. Vent Connection "C" Thd.24) "b" Dia.5(9.38) Fully 334(13.247) 187. 4.8 (2.743 (1.74) 5050ST-∗-∗-∗-RL-4080 5050ST-∗-∗-∗-RL-4090 27.16) T P1 P2 95.000 (. "C" Thd.48) 20.000 (1.078) 27. :50150ST-∗-∗-F-RL-40/4080/4090 Foot Mtg.76) INC.91) 117. 169 (6.F 1/4 BSP.5 (4.53) 4 Places Fully Extended Vent Connection "C" Thd.5 117.5 50150ST-∗-∗-∗-RL-4090 (8.02) Dia 388(15.990) 241 (9.5(15.15) 224 (8.65) 105 (4.000 (1.500) 38.3750) (2.050 (1.647) 9.76) Spotface 394. Through 6 Places e g "n" Dia.Tr 1/4 NPT 50150ST-∗-∗-∗-RL-4090 2 NPT 1-1/4 NPT 1/4 NPT Model Numbers E F Dimensions mm (Inches) H J K 10.13) I N 220(8. Small Volume Pump Discharge Port "B" Thd.5(.075 (1.02) L 30(1. 245(9.50) 175(6. Rc 2 "B" Thd.150T.".7 (. 70 (2. (2.55) 74 (2.97) H P Q "J" Dia.75) 25.654) 41.28) P2 P2 d Large Volume Pump Relief Pressure Adjustment Handle F 102 (4. "h" Dia.F 1/4 BSP.3760) 57 63. Pressure Gauge Connection "D" Thd.68) 120.:50150ST-∗-∗-L-RL-40/4080/4090 Fully Extended 394.5 70 (2.5(. "C" Thd.82) 174 (6.72) 75 (2.89) 120 (4.89) Tank Port "B" Thd. Rc 1/4 50150ST-∗-∗-∗-RL-4080 2 BSP.38) Dia.000 (1.5(8.24) (2.662) 42.4951) 42. 315(12.83) 6.128 (7.66) 120 (4.5(15.5 38. Small Volume Pump Relief Pressure Adjustment Handle b 17.40) DIMENSIONS IN MILLIMETRES (INCHES) Model Numbers 50150ST-∗-∗-∗-RL-40 "A" Thd.19) INC.69) Dia.4961) 9.02) Vent Connection "C" Thd.4990) 9. T For other dimensions.95) 22 (.525 (.20) 203.626) 275(10.3 (9.50) 50150ST-∗-∗-∗-RL-40 No.87) 5 (.5 (.4980) 42. refer to "Foot Mtg.83) 50(1.69) 76 (299) 21 (.550 (.18) 165(6.53) 131.97) (2.7 (1.250F Series Combination Pump-Type "50150ST" VANE PUMPS Installation Drawing Flange Mtg.997) 241.656) Dimensions mm (Inches) b d e L N P Q a f g h n 220 (8.839 (1.21 B .65) Large Volume Pump Discharge Port "B" Thd.7 (.72) 25 (. Rc 1/4 Rc 1-1/4 "D" Thd.85) 119 (4. "4080" Design Only K 10 (.3923) (1.626) (4.86) 175 (6.01) 3. Through 70 206.000 (.66) "E" Key Width 250(9.520) 37. 280(11.13) 35(1. Pressure Gauge Connection "D" Thd.12) 225 (8.98) 3 (. N 150 (5.000) 203.200 (8.F 1-1/4 BSP.49) 50150ST-∗-∗-∗-RL-4080 220.26) 203.7 (4.18) f Suction Port "A" Thd.39) P2 14 (.000 (7.992) 202.50T.3937) 50 64 38.76) (5.91) 4. P1 a 102 (4.975 (1.954 (7.075 (1.69) Dia.964 (.84) P1 P1 T 17.225 (1. 36) 138.674 (6.15) Extended 17.89) 131 (5.50) Fully 334(13.48) 20.5(7.9980) E Dimensions mm (Inches) N P J K L 5050CT-∗-∗-∗-∗-RL-40 28.36) 216 (8.69) Dia.26) 158.50T.979 (.72) 195.000) 25.25 (3.250F Series Combination Pump-Type "5050CT" VANE PUMPS Installation Drawing Foot Mtg. "b" Dia.80) 6.500) 167.7 (.3 (.79) 6 (. 120 (4. F 3 (.63) I N 80 (3.19) 51(2. refer to "Foot Mtg.74) 5050CT-∗-∗-∗-∗-RL-4080 5050CT-∗-∗-∗-∗-RL-4090 27.969) 25.24) a P1 175(6.1874) 4. Tank Port "B" Thd.760 (.960 (6.01) 70 (2.15) 57 (2.299) 159. 197(7.000 (.964 (.12) J P2 T INC.3 (6.5 (.1862) 50.53) Dia.76) 13.76) 98(3.543) 167 (6.250) 158.5(.45) 187.50) 16(.092) 90 (3.70) L 35(1.: 5050CT-∗-∗-F-∗-RL-40/4080/4090 Fully Extended 314(12.47) 76 (2.79) (3. T P1 P2 216(8.75) a b c 20 (.06) Dia.2756) 6.24) 160.9843) 24. "C" Thd.8 (2.22 Dimensions mm (Inches) F H "A" Thd.: 5050CT-∗-∗-L-∗-RL-40/4080/4090 Flange Mtg.63) Low Pressure Gauge Connection "D" Thd.57) 95 (3.191 (1. Discharge Port "B" Thd.298) 190 (7.730 (.000 (6.5(5.743 (1.16) P2 Vent Connection "C" Thd. Through 28(1. 139(5.102) 27.370 (.5(. "B" Thd. DIMENSIONS IN MILLIMETRES (INCHES) Model Numbers 5050CT-∗-∗-∗-∗-RL-40 5050CT-∗-∗-∗-∗-RL-4080 5050CT-∗-∗-∗-∗-RL-4090 Model Numbers No. Through 6 Places "d" Dia.10) Dia.9988) 25.27) 244.9 (3.370 (1.247) 187.F 3/4 NPT 1/4 BSP.99) Fully Extended P1 15 (.078) 27.59) 5 (.F 1/4 NPT 1/4 BSP.2742) 50 (1. High Pressure Adjustment Handle High Pressure Gauge Connection "D" Thd. "D" Thd. Suction Port "A" Thd. K 210(8.3 (7.349 (.5(9.38) 100 20(.5(7.38) For other dimensions.071) 88. Spotface 4 Places 230(9. Rc 1-1/2 Rc 3/4 Rc 1/4 Rc 1/4 7.750 (6.F 1-1/2 NPT 3/4 BSP.000 (1.Tr 1/4 NPT 4.9834) 1-1/2 BSP.". "E" Key Width 314(12.37) .20) 32(1.59) 95.91) K N "H" Dia.20) 4.150T.26) 5 (.86) Unloading Pressure Adjustment Screw "4080" Design Only P INC.000 (. : 50150CT-∗-∗-F-∗-RL-40/4080/4090 P2 P2 b 17.7 (4.5(15.18) 165(6.82) 174 (6.954 (7.02) 74 (2.89) Fully Extended Vent Connection "C" Thd.50T.075 (1.68) 120.66) 105 (4.50) 245(9.66) 120 (4.55) T K P1 10 (. DIMENSIONS IN MILLIMETRES (INCHES) Model Numbers 50150CT-∗-∗-∗-∗-RL-40 "A" Thd.3937) 50 64 38. B Flange Mtg.7 (1.4980) 42. "D" Thd. P P2 INC.98) 3 (.4990) 50150CT-∗-∗-∗-∗-RL-4090 2 NPT 1-1/4 NPT 1/4 NPT 1/4 NPT 9.5 (.4951) 42.39) 105 (4.91) 117. refer to "Foot Mtg.520) 37.02) Dia Suction Port "A" Thd.26) 203. N Q "J" Dia. 102 (4.839 (1. 280(11.5(.3750) (2.7 (.95) 22 (.: 50150CT-∗-∗-L-∗-RL-40/4080/4090 Fully Extended 394.997) 241.200 (8.075 (1.000 (7. 315(12. "B" Thd.89) 75 (2.4961) 9.72) 25 (.85) 76 (2.975 (1.Tr 9.12) 225 (8.5(15.38) Dia.5 117.000 (.87) 5 (. Through 6 Places d f "h" Dia.24) (2.75) 25.28) 169 (6.76) L 50(1.550 (.992) 202. Discharge Port "B" Thd.647) 50150CT-∗-∗-∗-∗-RL-4080 2 BSP.5 (7.3923) (1.F 1-1/4 BSP.5 50150CT-∗-∗-∗-∗-RL-4090 (8.5(10.F 1/4 BSP. Through 35(1.91) F 158(6.525 (.53) 388(15.3 (9.5 38. High Pressure Gauge Connection "D" Thd.23 . High Pressure Adjustment Handle Unloading Pressure Adjustment Screw 70 (2.02) 14 (.93) e "E" Key Width 250(9.65) 220(8.15) 224 (8.3760) 57 63.13) I N P1 201.964 (.53) For other dimensions.20) 203.22) 4.83) 6.500) 38.225 (1.97) (2. E F Dimensions mm (Inches) H J K 10.01) 3.49) 50150CT-∗-∗-∗-∗-RL-4080 220.F 1/4 BSP.69) Dia.86) 175 (6.50) 50150CT-∗-∗-∗-∗-RL-40 No. a 394.654) 41.65) Tank Port "B" Thd.40) Low Pressure Gauge Connection "D" Thd.656) Model Numbers Rc 2 Rc 1/4 Rc 1/4 Rc 1-1/4 Dimensions mm (Inches) b d e L N P Q a f g h 220 (8.5(.5 (4.". Spotface 4 Places 276.150T.000 (1.99) 21 (.97) H 150 (5. "C" Thd.84) P1 T 17.128 (7.626) 275(10.7 (.83) 30(1.250F Series Combination Pump-Type "50150CT" VANE PUMPS Installation Drawing Foot Mtg.990) 241 (9.69) Dia.19) "4080" Design Only Fully Extended INC. "g" Dia.626) (4.050 (1.662) 42.000) 203.000 (1. please do it carefully after reading through the relevant instructions in the Operator's Manual. Seal Kits Model Numbers 5050ST-∗-∗-∗-RL-40∗ 50150ST-∗-∗-∗-RL-40∗ 5050CT-∗-∗-∗-∗-RL-40∗ 50150CT-∗-∗-∗-∗-RL-40∗ Seal Kit No. beanings or cartridge kits. see page 11. KS-5050ST-40 KS-50150ST-40 KS-5050CT-40 KS-50150CT-40 .24 Qty. please specify the seal kit number from the table below.150T. 5050ST 50150ST 20 5 6 1 8 7 18 21 16 22 13 20 15 33 63 32 26 31 30 55 66 68 61 14 34 23 50 11 39 17 38 51 37 59 36 24 35 3 53 2 X X 9 65 29 28 58 25 27 61 53 67 57 56 64 52 4 19 5050CT 50150CT 5 20 6 8 7 18 22 21 13 4 20 15 9 34 33 63 32 31 30 26 55 45 49 44 62 14 36 43 23 50 40 11 39 2 38 3 17 1 37 59 35 60 65 47 27 46 53 X X 24 29 16 28 53 58 25 61 41 42 56 61 54 57 52 48 64 51 19 Seals & Bearings Part Numbers Item Name of Parts 15 16 17 18 58 59 60 61 62 63 64 65 13 14 Oil Seal O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring Bearing Bearing 5050ST 50150ST 5050CT 50150CT ISPD 325211 SO-NA-P52 SO-NA-A234 SO-NA-A234 SO-NB-G40 SO-NB-P28 ISPD 406212 SO-NA-P62 SO-NA-A234 SO-NA-A248 SO-NB-P48 SO-NB-P40 SO-NB-G30 SO-NB-P36 SO-NA-P9 SO-NB-P6 SO-NB-G40 6305 6200 SO-NA-P9 SO-NB-P6 SO-NB-G40 6207 6200 ISPD 325211 SO-NA-P52 SO-NA-A234 SO-NA-A234 SO-NB-G40 SO-NB-P28 SO-NB-P24 SO-NB-G30 SO-NA-P15 SO-NA-P9 SO-NB-P6 SO-NB-G40 6305 6200 ISPD 406212 SO-NA-P62 SO-NA-A234 SO-NA-A248 SO-NB-P48 SO-NB-P40 SO-NB-P39 SO-NB-P36 SO-NA-P20 SO-NA-P9 SO-NB-P6 SO-NB-G40 6207 6200 Cartridge Kits Model Numbers Cartridge Kit Numbers 6 Small Volume Pump 8 Large Volume Pump 5050 CST- - C50- -30 C50- -30 50150 CST- - C50- -30 C150- -40 Notes:1) and are spaces for nominal displacement figures. 2) Cartridge kits are common with single pumps. No. 5050ST 5050CT 50150ST 50150CT 1 1 1 1 1 1 1 1 1 1 2 2 1 2 2 1 2 1 1 2 1 1 1 1 1 1 When ordering seals.250F Series Combination PumpType "5050SC T"&"50150 SC T" VANE PUMPS Spare Parts List CAUTION When making replacement of seals.50T. For details. Double B Up to 21 MPa (3050 PSI). To comply with a variety of applications including injection moulding machines. Graphic Symbol Double Pumps These double pumps consist of two PV2R seires single pumps combined in tandem within a single housing and driven by a common shaft.in./rev) Single Pumps These pumps are of high pressure and high performance.IN. Graphic Symbol No.Single. PV2R series single pumps provide the output flow of such a wide range as from 5.46 CU. which have been developed especially for low noise operation. Therefore.8 to 237 cm3/rev (. A Single suction port and two discharge ports are provided so that the output flow can be supplied to separate circuits.46 cu.1 . 237 cm3/rev (14. EC-0118 "PV2R" SERIES VANE PUMPS Fixed Displacement./rev). The intergral driving parts of the pumps are combined into a kit form and available for supply as a cartridge kit.Pub.354 to 14. the replacement of the driving parts can be done easily. 2 . Standard pumps can be used without conditions. Use phosphate ester type fluids. Viscosity mm2/s (SSU) PV2R1 PV2R12 PV2R13 PV2R14 750 100 (455) 950 200 (910) PV2R2 PV2R23 PV2R24 600 100 (455) 950 200 (910) 3. For details. please refer to the specifications of the pump concerned. Type of hydraulic fluids Any type of hydraulic fluids listed in the Table 1 below can be used. LTD. Fluid viscosity and temperature Fluid Petroleum Base Oils Phosphate Esters Water Glycols Water in Oil Emulsions Temperature °C (°F) (Table 3) Viscosity mm2/s(SSU) Pump Type 20-400 (100-1800) 0-70 (32-158) 0-50 (32-122) 5-50 (41-122) Maximum viscosity for low start-up speed (Table 4) Start-up Speed r/min Max. G-W Fluid 46 Mobile MATSUMURA OIL RESEARCH CORP. HYDOL HAW COSMO FLUID HQ 46 COSMO FLUID GS 46 2.Double VANE PUMPS Hydraulic Fluids Hydraulic Fluids 1. more than 50 mm (2 in. LTD HYRAND FRX 46 Irus Fluid C Showa Shell Sekiyu K. the maximum fluid viscosity is limited. Carry out sufficient contamination control for hydraulic fluids and keep contamination level within NAS class 12. When phosphate ester type fluid is used. However. COSMO OIL CO. JOMO Hydria NIPPON OIL CO. . if any type other than those in Table 2 is used. Hydraulic fluids (Table 1) "PV2R" Series Single Pumps "PV2R" Series Double Pumps Type of Fluids Petroleum Base Oils Synthetic Fluids Use anti-wear type oils or R & O (Rust and Oxidation inhibitor) type oils (equivalent to ISO VG32 or 46). the maximum operating pressure is limited. K. . Water-Glycols Water However."PV2R" SERIES Fixed Displacement-Single. the specifications of the pumps such as maximum pressure and maximum pump speed may be changed according to the type of hydraulic fluids to be used. No. prefix "F-" to the model number because the special seals (fluororubber) are required to be used. please note that if any of the pumps listed in the table 4 is started at low speed. Fluid viscosity and temperature Use the hydraulic fluids which satisfy the recommended viscosity and oil temperature given in the Table 3 below. Also. use a 100 μm (150-mesh) tank filter on the suction side. However.) away from the tank bottom. Control of contamination Contamination of hydraulic fluids results in pump failures and reduced pump lives. Containing Fluids Water in Oil Standard pumps can be used without conditions. Emulsions Anti-wear type water-glycols Fluid Manufacturer (Table 2) Commercial Trade Name Mobil Hydrofluid HFC 46 Mobil Nybac FR 200 D JAPAN ENERGY CORP. 3 PSIG) In relation to the rotating speed of the pump.3 ft. In case where the pump is installed on the tank or at the position higher than the tank top cover. and avoid any stress from bending or thrust.8 metre (2. Precautions at starting At an initial operation or at an operation after a long rest.1 mm (. see the item of "Hydraulic Fluids". In such cases. Maximum permissible misalignment is less than 0. install the pump with the suction port upside so that the pump can suck up fluid easily at starting. an air bleed valve should be installed beforehand on the discharge side (model No.).3 . the minimum suction pressure may be restricted for a certain nominal displacement. the height of the suction port of the pump should be less than 1 metre (3. or discharge air by slightly slackening the connection on the discharge side. At starting. EC-3001. Hg Vacuum) PV2R12 -20 kPa (5. Suction pressures Set the suction pressure at pump inlet port at the value given in the table below. Hg Vacuum) +30 kPa (+4. Suction Pressure Minimum Pump Type Petroleum base oil Single Pumps Double Pumps PV2R1 PV2R2 -20 kPa (5. For fluid viscosity at starting. operate the pump intermittently as far as possible with no load. the pump may have difficulty in sucking up fluid. Hg Vacuum) Phosphate ester type fluid Water containing fluid Maximum -16 kPa (4.6 ft.2°. Other precautions If a pump is used at speed below 1200 r/min.7 in. Hg Vacuum) PV2R13 PV2R23 PV2R33 PV2R14 PV2R24 PV2R34 -20 kPa (5. ST1004-∗-10∗.9 in. For details. Hg Vacuum) PV2R3 PV2R4 -20 kPa (5.9 in. 2. 3.Double Instructions VANE PUMPS B Instructions 1. Catalogue No.9 in. Pub.9 in. 4. No.) from the oil level {less than 0."PV2R" SERIES Fixed Displacement-Single. please refer to the specifications of the pump concerned.) in case of using phosphate ester fluids or water containing fluids}. Alignment of shaft Employ a flexible coupling whenever possible. use the pipes in the suction side having the diameter as indicated on the installation drawings.004 inches) TIR and maximum permissible misangular is less than 0. Furthermore. . European Design Standard 90 ..4 .. 59 65 76. EC-3001. . 47 53. . American Design Standard Suction F5-08-A-10 F5-08-A-1080 F5-08-A-1090 F5-08-B-10 F5-08-B-1090 F5-08-C-10 F5-08-C-1090 Discharge F5-04-A-10 F5-04-A-1080 F5-04-A-1090 F5-04-B-10 F5-04-B-1090 F5-04-C-10 F5-04-C-1090 Suction F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090 Discharge F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090 Suction F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090 Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090 Suction F5-24-A-10 F5-24-B-10 F5-24-B-1090 F5-24-C-10 F5-24-C-1090 Discharge F5-12-A-10 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090 F5-12-A-1080 F5-12-A-1090 In case of using socket welding flanges.. American Design Pipe Flange Kits Standard Pipe flange kits are available. 31 41. 2. 12 14. No. Notes: Special seals (Viton seals) are required when phosphate ester type fluids are used. American Design Standard Socket Welding Japanese Standard "JIS" European Design Standard Butt Welding N. When ordering. 94 116 (Viewed from Shaft End) L: 40 Foot Mounting R: F: A: A: Clockwise 1 Upwards Upwards (Normal) (Normal) (Normal) Flange 40 Refer to 2 30 Mounting 136. Therefore. 23 25. ..) Details of the pipe flange kits are given in the Catalogue No. 8 10. N. please pay cautious attention to the operating pressure when the socket welding flanges are used.. . Available to supply pump with anti-clockwise rotation. Design Standards: None. there is a case where the operating pressure should be set lower than the normal because of strength of the flanges.Japanese Standard "JIS" 80 .... 17 19. specify the kit number from the table below.."PV2R" SERIES Single Pump-Type PV2R1 / PV2R2 / PV2R3 / PV2R4 Model Number Designation / Pipe Flange Kits VANE PUMPS Graphic Symbol Model Number Designation F- PV2R1 -6 -L -R A A -40 -∗ Special Seals Series Number Nominal Displacement cm3/rev Type of Mounting Shaft Rotation Discharge Port Position Suction Port Position Design Number Design Standards PV2R1 F: For phosphate ester type fluids (Omit if not required) PV2R2 PV2R3 PV2R4 6. . . American Design Standard Japanese Standard "JIS" European Design Standard N.. 153 184. (Prefix "F-" to the pipe flange kit number when ordering. Pub. 200 237 30 1. . Consult Yuken for details. Pipe Flange Kit Numbers Pump Model Numbers PV2R1 PV2R2 PV2R3 PV2R4 Name of Port Threaded Connection Japanese Standard "JIS" European Design Standard N... see the item of "Hydraulic Fluids" on page 3.3 ( 1.5 ( 34.26 ) Petroleum Base Oils Anti-Wear Type MPa (PSI) Water Containing Fluids R&O Type Anti-Wear Type Water Glycols 16 (2320) Synthetic Fluids 1 Output Flow & Input Power Water Glycols Water in Oil Emulsions Phosphate Esters 16 (2320) 7 (1020) 7 (1020) 16 (2320) 14 (2030) 16 (2320) 7 (1020) 7 (1020) 14 (2030) Refer to Pages 13&14 14 (2030) 16 (2320) 7 (1020) 7 (1020) 14 (2030) Refer to Page 15 Shaft Speed Range r/min Max. vacuum).2 ) 68.4 ( .5 ( 3. Mass Model Numbers PVR2R1 PVR2R2 PVR2R3 PVR2R4 Approx.4 ( 4.1 ) 40.2 ( 2.5 (2540) 14 (2030) 16 (2320) 7 (1020) 7 (1020) 14 (2030) Refer to Pages 15&16 1800 (1200) 1800 (1200) 1800 (1200) 2 5 600 4 4 600 3 4 For the brands of anti-wear water-glycols ./rev) PV2R1-6 PV2R1-8 PV2R1-10 PV2R1-12 PV2R1-14 PV2R1-17 PV2R1-19 PV2R1-23 PV2R1-25 5.). the maximum viscosity is limited. Hg. Operating Pressure Model Numbers Geometric Displacement cm3/rev (cu.5 (151 ) 93. ( 8."PV2R" Series VANE PUMPS Single Pump . 5.135 ) 22.354 ) 8.488 ) 9.3 ( 2.in.5 (206 ) No.9 ( 90.05 ) PV2R4-136 PV2R4-153 PV2R4-184 PV2R4-200 136 153 184 201 PV2R4-237 237 ( 14.88 ) 52. the maximum speed is limited to 1200 r/min. Mass kg (lbs.2 ) 19.6 ( 1. If phosphate ester or water containing fluids are used. Hg.892 ) PV2R2-41 PV2R2-47 PV2R2-53 PV2R2-59 PV2R2-65 PV2R3-76 PV2R3-94 41. the suction pressure is limited to -13 kPa (3. For pressure above 16 MPa (2320 PSI).6 ( 1. 6.2 ( .6 ( 7.8 ( 43.7 ) 15.7 ( 3.95 ) 76.744 ) 13.385 ) 25.71 ) PV2R3-116 115.836 ) 16.013 ) 18.30 ) ( 9.9 ( 68. the suction pressure is limited to 0 kPa (0 in. see the item of "Hydraulic Fluids" on page 3.5 B . For details.0 ( 1.Type PV2R1/PV2R2/PV2R3/PV2R4 Specifications Specifications Max.8 ( . For starting at low speed.55 ) 64.66 ) 93.46 ) 1. Foot Mtg.8 ) 11.7 ( .7 ) 30.) Flange Mtg.574 ) 12. If PV2R4-237 is used at speed above 1700 r/min.6 ( 5.0 ( 19. 4.20 ) 58.2 ( 3.544 ) PV2R1-31 31.23 ) ( 12.7 ( 1.34 ) ( 11.2 ( 24. Min. If PV2R3-116 is used at speed above 1700 r/min.0 ( . 21 6 (3050) 21 (3050) 1800 Refer to Pages 11-13 (1200) 4 750 1800 (1200) 4 600 1800 (1200) 4 5 16 (2320) 21 (3050) 21 (3050) 16 (2320) 17.52 ) 47.94 in. 2. 3. raise the speed over 1450 r/min. 9. 57) 56 (2.51) Suction Port 28(1.5 (4.689) 178.276) R9.42) 25 (.5 (2.472) Dia.830) A 58 (2.5 (2. E mm (Inches) M10 M8 14 (.74) 33 (1.31) 38.74) 62 (2.94) Dia. 17(.37) R8(R.20) 26.73) "C" Thd.969) 95 (3.59) Dia.760 Key Width (.: PV2R1-∗-L-RAA-40/4090 12(.5 (1. "E" Deep 4 Places Port Position 130 (5.6 145.50 (3.5 (7.1874) Discharge Port 15(.15) A 3 (.1887) (. Through 29(.55 Dia.854) 72.12) 106 (4.55) 3/8-16 UNC 5/16-18 UNC 16 (.63) PV2R1-∗-F-RAA-40 PV2R1-∗-F-RAA-4090 DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.854) 180 (7.250) (3.5(R. Spotface 4 Places 69.09) For other dimensions. No.28) 69.82) Sq.7500) Dia.44) 95 (3. refer to "Flange Mtg.12) 178. Model Numbers .08(.500) 52.248) R12 (R. 7 (.5 (2.71) 82.74) 15 (.59) 80 (3.5 (7.47) 97(3. 21. 95(3.19) 4.". 82.03) 56 (2.20) "D" Thd.67) Deep 4 Places 106.: PV2R1-∗-F-RAA-40/4090 13 (.793 4.24(.5 (2.7488) "C" Thd.031) 17.5(5.03) 56 (2.74) 44.02(.Type "PV2R1" VANE PUMPS Installation Drawing Flange Mtg.17) 11(."PV2R" Series Single Pump .98) 19.4 (2.75) 36 (1.20) 50 (1.05(.10) Dia.433) Dia.5 (. 19. Through 2 Places 18 (.063) 40(1.30) 72.2 (1.1 (1.836) 21.74) "D" Thd. 10) Dia.43) 15 (.22) 6.02) A 3 (.67) Deep 4 Places 22.85) 146 (5.12) 222 (8. Through 28(1.85) 32 (1.531) Dia."PV2R" Series Single Pump .000) (3.354) R11(R.9980) 28.740) 230 (9. 25.5(.748) 125 Sq.56) 30.7 .: PV2R2-∗-L-RAA-40/4090 14(. PV2R2-∗-F-RAA-40 PV2R2-∗-F-RAA-4090 120(4.2500) Discharge Port 21(.60 Dia.35) 47.38 6.6 (1.79) "C" Thd.63) Suction Port 34(1.".75) 7/16-14 UNC 3/8-16 UNC 20 (.189) "D" Thd.: PV2R2-∗-F-RAA-40/4090 16 (.15) 60 (2.874) 222 (8.15) Port Position A 174 (6.74) 80 (3.59) 102 (4.43) 59 (2.26) 25.98) 101.Type "PV2R2" VANE PUMPS Installation Drawing B Flange Mtg.34) Dia.72) 73 (2.2 (.2 (1.72) DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.32) 47 (1.06) For other dimensions.50) 95 (3. Spotface 4 Places 87 (3. No.40( 1.107) "C" Thd. 120 (4.87) 38 (1.83) Dia.76) 87 (3. 101.740) 95 (3.362) 115 (4. (4.13(1. 9 (. Through 2 Places Model Numbers "D" Thd.998) 13. E mm (Inches) M10 M8 19 (.55) 25 (.5 (5.55) Dia.43) R9(R. refer to "Flange Mtg.874) 58.93) 65(2.44) 70 (2.2512) (.35( .35 Key Width (.311) 49(1.74) 80 (3.18(1. "E" Deep 4 Places 132.53) 189(7.0000) Dia.55 (4. 17(.92) R14 (R.109) 28.7 (2. 998) R16 (R.126) 31 (1."PV2R" Series Single Pump .75) 19 (.75(1.56) 87(3.71) 50 (1.16) 145 (5.8 217(8.95 (5.01) Dia.02) Dia.391) 35.75) 1/2-13 UNC 7/16-14 UNC 21 (. Through 26(1.689) Dia.311) 77.: PV2R3-∗-F-RAA-30/3090 21 (.83) 20 (.14(1.689) 31.54) 112 (4. (6.48) 40 (1.: PV2R3-∗-L-RAA-30/3090 17.32(1. No.2500) Dia.5(.79) 90 (3.9 (1.5(.39) 181 (7. 9 (.189) Port Position A 213 (8. . 31.Type "PV2R3" VANE PUMPS Installation Drawing Flange Mtg.41) 23 (. E F M12 M10 19 (.91) 109.95) 63 (2.689) Dia. Through 2 Places Model Numbers PV2R3-∗-F-RAA-30 PV2R3-∗-F-RAA-3090 166 Sq.354) R11(R.".43) R13(R. Spotface 4 Places 112 (4.626) 117.10) Dia.54) 76.5 (4.08) 274 (10.54) 173 (6.2480) 35.43) 30.79) For other dimensions.79) DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.46) 131 (5.94 Key Width (.8 (3.7 (2.51) 58.2 (1. "E" Deep 4 Places 7.000) (3.31) A 2(.54) "D" Thd.63) 17. 126.00 Dia. refer to "Flange Mtg. "D" Thd.3138) (.2 88 (3.57) 90 (3.626) 274 (10.97 7.81) 274 (10.063) 65(2.5 (4.000) (4.41) 75 (2.22) 127.79) 90 (3.70(1.97) 117.83) Suction Port 51(2.3126) Discharge Port 28(1.383) "C" Thd.83) Dimensions mm (Inches) "C" Thd.5 (4. "F" Deep 4 Places 148 (5.54) 42. 24) For other dimensions.35 (6.6(9.36) 187. "F" Deep 4 Places 35. 280 (11. 9.3(12.31) A 3 (.98) (2.83) 21 (.89) 135 (5.20) 152.3 (7.46) R13(R.65) R15(R.3 (7.4980) 42.9 .37) 118(4.3 (7. Spotface (From Rear) 4 Places PV2R4-∗-F-RAA-30 PV2R4-∗-F-RAA-3090 "C" Thd. "E" Deep 4 Places 25 61."PV2R" Series Single Pump .3764) (.51) 354 (13.668) 42.28) R22(R.5(.000) 115 (4.406) 187.59) R37(R1.866) Dia. 152.62) 76 (2.500) 185 (7.000) (5. "D" Thd.". Spotface 4 Places 135 (5. refer to "Flange Mtg.661) Suction Port 76(2.75) 19 (.42) Dia.99) Dia.9 (2.54) Dia.94) 110 (4.7 (1.56 9.53) 21.374) 187.6(9.53 Key Width (.3752) Discharge Port 36(1.998) 140 (5.83) DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.36(1.437) 38.846) Dia.02) 99 (3.5000) Dia.90) 60 (2.33) 217 (8.752) 106.31) 92 (3. 38.75) 1/2-13 UNC 5/8-11 UNC 21 (.: PV2R4-∗-L-RAA-30/3090 22(.374) 438 (17.512) Port Position A 273(10. Through 39(1.12) 354 (13.189) "C" Thd.18(1.3 (4.33) 30 (1.000) 228.54) "D" Thd.94) 110 (4.Type "PV2R4" VANE PUMPS Installation Drawing B Flange Mtg. Through 43(1.51) 69.40 Dia.05(1.4 (4.9 (.10(1.18) Model Numbers 114.87) 327. 228.69) Dia. No. Dimensions mm (Inches) E F M16 M12 19 (.: PV2R4-∗-F-RAA-30/3090 13 (.75) Sq.99) 56 (2. 5 21 (1000) (2000) (3000) (PSI) 0 3.) horizontally away from pump head cover Back ground noise : 40 dB (A) PV2R1-6 dB(A) 60 55 1200 r/min 55 50 1200 r/min 1000 r/min Noise Level Noise Level PV2R1-31 dB(A) 60 45 1000 r/min 50 45 40 40 0 3.5 21 (1000) (2000) (3000) (PSI) Pressure .5 14 17.5 MPa 7 10.5 45 MPa 7 10.5 14 17.5 14 17.3 ft.5 Noise Level Noise Level 1200 r/min 60 60 1000 r/min 55 50 MPa 7 10.5 PV2R4-136 PV2R4-184 dB(A) 70 1200 r/min 1000 r/min 60 55 0 3.5 MPa 7 10.10 Noise Level Noise Level 1200 r/min 65 MPa 7 10.5 14 17.5 PV2R3-76 dB(A) 65 PV2R3-116 dB(A) 65 1200 r/min 1000 r/min 55 0 3.5 14 17.5 21 (1000) (2000) (3000) (PSI) Pressure No.5 21 (1000) (2000) (3000) (PSI) Pressure Pressure 50 MPa 7 10.5 14 17."PV2R" Series Single Pump-Type PV2R1 / PV2R2 / PV2R3 / PV2R4 Typical Pump Characteristics VANE PUMPS Noise Level Measuring conditions Fluid viscosity : 20 mm2/s (100 SSU) Measurement point : One metre (3.5 21 (1000) (2000) (3000) (PSI) 0 3.5 0 MPa 7 10.5 21 (1000) (2000) (3000) (PSI) 3.5 21 (1000) (2000) (3000) (PSI) Pressure Pressure dB(A) 70 MPa 7 10.5 14 17.5 Pressure Pressure PV2R2-41 dB(A) 65 60 1200 r/min 55 1000 r/min Noise Level Noise Level PV2R2-65 dB(A) 65 60 50 45 1200 r/min 55 1000 r/min 50 0 3.5 21 (1000) (2000) (3000) (PSI) 65 1000 r/min 60 55 0 3.5 14 17. 8 1.2 2.8 3.5 14 17.4 1800 r/min 4.0 2.2 kW 10 19 1500 r/min 9 18 8 17 16 7 6 15 1200 r/min 5 14 13 4 1000 r/min 3 12 2 11 1 10 0 9 0 3.6 2."PV2R" Series Single Pump .5 21 MPa 3.GPM 3.8 2.2 1.S.4 20 U.5 (1000) (2000) (3000) (PSI) 16 Pressure (2320) 3.8 10 2.S.0 7 1.4 3.GPM 4.5 21 (1000) (2000) (3000) (PSI) Pressure 1200 r/min kW HP 10 7 1000 r/min 6 8 5 6 4 3 4 2 2 1 0 0 MPa 7 10.11 .6 6 5 1.4 9 8 2.6 14 13 12 11 10 9 8 7 6 1500 r/min PV2R1-12 Input Power L/min 18 17 16 4.0 1.5 14 17.S.5 14 17.5 21 (1000) (2000) (3000) HP 14 12 10 8 6 Input Power U.8 1800 r/min Output Flow 3.GPM L/min 11 2.4 Output Flow 1500 r/min 1200 r/min 0 2.0 kW HP 11 8 10 1200 r/min 7 6 8 1000 r/min 5 6 4 3 4 2 2 1 0 0 MPa 3.S.8 3 PV2R1-8 L/min 15 14 13 12 11 10 9 8 7 6 5 Input Power PV2R1-6 4 2 0 MPa (PSI) Pressure No.4 Input Power 1000 r/min kW HP 6 8 5 6 4 3 4 2 2 1 0 0 7 10.5 7 10.2 4 .0 15 U.5 21 3.GPM 5.6 Output Flow Output Flow 3.4 2.0 0 PV2R1-10 3.Type "PV2R1" VANE PUMPS Typical Pump Characteristics B Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.5 7 10.6 0 1800 r/min 1500 r/min 5.6 2.8 4. 50°C (122°F)] U.2 3.5 (1000) (2000) (3000) (PSI) 16 Pressure (2320) L/min 23 22 1800 r/min 21 5.5 14 17. 12 20 16 20 10 15 5 12 8 4 0 0 0 3.GPM 11 1800 r/min 25 1200 r/min 6 5 4 3 Output Flow 1500 r/min 7 20 1000 r/min kW HP 15 20 16 10 15 5 10 L/min 45 1800 r/min 40 10 30 12 8 4 Input Power Output Flow L/min U.5 21 (1000) (2000) (3000) (PSI) 1200 r/min Pressure Pressure PV2R1-19 8 PV2R1-23 U.GPM 7 PV2R1-17 L/min 32 30 28 26 24 22 20 18 16 14 12 Input Power PV2R1-14 L/min 28 26 24 22 20 18 16 14 12 10 .5 21 MPa (1000) (2000) (3000) (PSI) kW 20 HP 24 0 3.S.5 21 MPa (PSI) (1000) (2000) (3000) Pressure Input Power 5 1800 r/min Output Flow Output Flow 6 U.5 21 (1000) (2000) (3000) (PSI) 1000 r/min 6 5 4 3 0 1800 r/min 1500 r/min kW HP 20 14 12 1000 r/min 16 10 12 8 6 8 4 4 2 0 0 MPa 3.5 7 10.S.GPM 8 Input Power U.S.5 14 17.5 14 17.5 14 17.5 7 10.5 14 17.GPM 40 10 35 9 9 8 7 35 1500 r/min 30 1200 r/min 15 25 1000 r/min 6 5 4 0 Pressure No.S.5 0 7 10. 50°C (122°F)] 4 3 2 0 7 1500 r/min 1200 r/min kW HP 12 16 10 12 8 6 8 4 4 2 0 0 MPa 3."PV2R" Series Single Pump-Type "PV2R1" VANE PUMPS Typical Pump Characteristics Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.5 7 10. 5 21 (1000) (2000) (3000) Pressure 0 U.5 21 (1000) (2000) (3000) (PSI) Pressure HP 50 40 30 20 10 0 0 kW 40 10 Input Power 8 50 1500 r/min Output Flow Output Flow 40 10 0 0 3.5 0 MPa 7 10.5 0 MPa 7 10.GPM L/min 20 75 kW 20 20 20 0 6 Input Power 4 1000 r/min 30 Input Power 1200 r/min 30 1500 r/min 12 1000 r/min 40 30 30 20 3.S.S.GPM 23 22 1500 r/min 50 1200 r/min 12 8 0 0 MPa 7 10. 50°C (122°F)] PV2R1-25 U.S.GPM L/min 50 16 L/min 60 1800 r/min 1800 r/min 14 1000 r/min 10 40 1200 r/min 6 20 8 kW 20 HP 30 10 10 3."PV2R" Series Single Pump .5 14 17.5 80 40 70 16 60 1500 r/min 1200 r/min 14 12 kW 30 30 18 50 1000 r/min 20 HP 40 30 20 10 10 10 Input Power Output Flow 16 10 Output Flow 18 20 1800 r/min 70 HP 30 10 0 MPa (PSI) PV2R2-41 U.GPM 13 12 PV2R1-31 U.5 14 17.Type "PV2R1 & PV2R2" VANE PUMPS Typical Pump Characteristics B Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.5 21 (1000) (2000) (3000) (PSI) 16 Pressure (2320) PV2R2-47 L/min 85 1800 r/min 20 60 14 10 3.S.5 0 7 10.5 14 17.5 14 17.5 21 (1000) (2000) (3000) (PSI) Pressure No.13 . 5 7 10.GPM L/min 30 110 10 0 MPa (PSI) Input Power U.5 14 17.5 14 17.S.GPM L/min 30 110 ."PV2R" Series Single Pump-Type "PV2R2" VANE PUMPS Typical Pump Characteristics Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.S. 50°C (122°F)] PV2R2-53 PV2R2-59 100 18 80 Output Flow 90 22 26 1800 r/min 1500 r/min 70 60 1200 r/min 14 50 1000 r/min 10 40 kW 40 30 20 0 0 3.5 50 10 40 1000 r/min 20 0 3.5 7 10.GPM 34 130 120 30 110 90 22 HP 50 20 10 1800 r/min 100 Input Power Output Flow 26 U.14 3.5 14 17.5 21 (1000) (2000) (3000) Pressure HP 60 50 40 30 10 0 0 MPa 7 10.S.5 21 (1000) (2000) (3000) (PSI) Pressure HP 60 50 40 30 20 0 0 MPa (PSI) 20 10 14 10 Input Power Output Flow 18 1200 r/min 60 10 1500 r/min 90 22 70 30 1800 r/min 100 18 1500 r/min 40 PV2R2-65 26 80 kW 40 L/min 140 U.5 21 (1000) (2000) (3000) Pressure 30 80 1200 r/min 70 1000 r/min 60 14 kW 50 50 40 30 20 0 No. 5 14 17.Type "PV2R3 & PV2R4" Typical Pump Characteristics VANE PUMPS B Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.S.S.5 30 10 0 MPa 7 10.GPM L/min 56 210 48 60 40 Pressure 52 80 50 0 0 HP 100 60 Input Power 20 40 110 90 22 50 30 1500 r/min 130 120 30 26 40 50 140 Input Power 26 150 38 1500 r/min 110 Output Flow Output Flow 120 30 1800 r/min 40 30 20 10 0 0 HP 120 100 80 60 40 Input Power 34 L/min U.GPM 170 44 42 160 20 0 17.15 .5 14 17.5 7 10."PV2R" Series Single Pump .5 14 17.5 21 (PSI) (1000) (2000) (3000) 0 32 28 24 U.5 21 (1000) (2000) (3000) Pressure 16 (2320) 70 HP 80 60 50 60 40 20 0 MPa (PSI) Input Power Output Flow 36 20 L/min 190 40 10 0 3.S. 50°C (122°F)] PV2R3-94 PV2R3-76 U.5 MPa 3.GPM L/min 38 140 1800 r/min 130 100 90 22 18 kW 60 1200 r/min 80 1000 r/min 70 50 60 14 HP 80 70 34 60 30 20 10 1200 r/min 100 1000 r/min 18 80 kW 70 70 3.GPM 280 70 260 1800 r/min 200 1800 r/min 240 Output Flow 180 1500 r/min 170 160 150 60 140 1200 r/min 130 220 1500 r/min 200 50 40 30 180 1200 r/min 160 140 1000 r/min 120 kW 80 100 120 1000 r/min 110 100 kW 60 90 50 40 30 20 10 0 0 0 MPa (PSI) PV2R4-136 3.5 14 (500) (1000) (1500) (2000) (2500) (PSI) Pressure No.5 21 (1000) (2000) (3000) Pressure PV2R3-116 44 40 20 U.5 7 10.S.5 7 10. 5 14 10.5 MPa 7 3.S.S.GPM L/min ."PV2R" Series Single Pump-Type "PV2R4" VANE PUMPS Typical Pump Characteristics Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.5 14 7 10.16 60 40 1800 r/min 420 400 kW 380 140 120 320 110 300 100 1200 r/min 90 80 260 1000 r/min 240 60 130 1500 r/min 340 280 70 70 220 60 200 50 50 40 40 20 10 0 0 17.5 (500) (1000) (1500) (2000) (2500) (PSI) 0 70 110 340 50 100 1500 r/min 300 280 kW 120 260 110 1200 r/min 240 60 U.S.GPM L/min 100 380 kW 110 20 0 HP 180 160 140 120 100 80 60 40 20 10 0 0 17.5 (500) (1000) (1500) (2000) (2500) (PSI) 30 20 0 100 L/min 360 HP 160 Output Flow Output Flow 80 120 PV2R4-237 1800 r/min 320 140 Pressure Input Power 90 HP 160 20 PV2R4-200 360 90 80 Pressure U.5 10.5 10.GPM 115 100 90 220 1000 r/min 200 80 70 180 60 40 50 40 30 140 120 90 80 100 80 60 440 No.5 14 (500) (1000) (1500) (2000) (2500) (PSI) Pressure Input Power 280 70 U.GPM L/min 90 340 300 Input Power 80 Input Power U.5 MPa 7 3.S.5 MPa 3. 50°C (122°F)] PV2R4-184 PV2R4-153 80 260 240 60 1500 r/min 220 200 50 40 30 1200 r/min 180 160 1000 r/min 140 kW 90 120 80 70 60 50 40 30 20 10 0 0 1800 r/min 320 Output Flow Output Flow 1800 r/min HP 120 80 60 40 280 70 1500 r/min 260 240 60 50 40 100 300 1200 r/min 220 200 100 1000 r/min 180 160 70 60 50 40 30 20 0 17.5 MPa 7 3.5 14 (500) (1000) (1500) (2000) (2500) (PSI) Pressure 80 20 10 0 0 17. 2) For pumps for phosphate ester type hydraulic fluids different part Nos. Pump Model Numbers PV2R1-∗-∗-RAA-40/4090 PV2R2-∗-∗-RAA-40/4090 PV2R3-∗-∗-RAA-30/3090 PV2R4-∗-∗-RAA-30/3090 PV2R4 ISD 45 68 12 SO-NB-G145 SO-NB-P28 SO-NB-P22A SO-NA-G130 SO-NA-G80 SO-BE-G130 SO-BB-G80 6209 Qty. 13 and 14 (o-rings) and 15 and 16 (back up rings) are included in cartridge kit.17 B . 1 1 1 1 1 1 1 1 1 Seal Kit Numbers KS-PV2R1-40 KS-PV2R2-40 KS-PV2R3-30 KS-PV2R4-30 No. 21 2 4 10 15 13 14 16 1 19 17 9 3 18 X 8 7 12 6 5 11 Y 22 23 24 29 20 Y Section Y-Y 26 25 Section X-X X 27 28 Cartridge Kits Model Numbers PV2R1-6-∗-RAA-40∗ PV2R1-8-∗-RAA-40∗ PV2R1-10-∗-RAA-40∗ PV2R1-12-∗-RAA-40∗ PV2R1-14-∗-RAA-40∗ PV2R1-17-∗-RAA-40∗ PV2R1-19-∗-RAA-40∗ PV2R1-23-∗-RAA-40∗ PV2R1-25-∗-RAA-40∗ PV2R1-31-∗-RAA-40∗ 4 Cartridge Kit Numbers CPV2R1-6-R-40 CPV2R1-8-R-40 CPV2R1-10-R-40 CPV2R1-12-R-40 CPV2R1-14-R-40 CPV2R1-17-R-40 CPV2R1-19-R-40 CPV2R1-23-R-40 CPV2R1-25-R-40 CPV2R1-31-R-40 Model Numbers PV2R2-41-∗-RAA-40∗ PV2R2-47-∗-RAA-40∗ PV2R2-53-∗-RAA-40∗ PV2R2-59-∗-RAA-40∗ PV2R2-65-∗-RAA-40∗ PV2R3-76-∗-RAA-30∗ PV2R3-94-∗-RAA-30∗ PV2R3-116-∗-RAA-30∗ PV2R4-136-∗-RAA-30∗ PV2R4-153-∗-RAA-30∗ PV2R4-184-∗-RAA-30∗ PV2R4-200-∗-RAA-30∗ PV2R4-237-∗-RAA-30∗ 4 Cartridge Kit Numbers CPV2R2-41-R-40 CPV2R2-47-R-40 CPV2R2-53-R-40 CPV2R2-59-R-40 CPV2R2-65-R-40 CPV2R3-76-R-30 CPV2R3-94-R-30 CPV2R3-116-R-30 CPV2R4-136-R-30 CPV2R4-153-R-30 CPV2R4-184-R-30 CPV2R4-200-R-30 CPV2R4-237-R-30 Seals & Bearings Item Name of Parts 9 10 11 12 13 14 15 16 17 Oil Seal O-Ring O-Ring O-Ring O-Ring O-Ring Back Up Ring Back Up Ring Bearing PV2R1 ISD 26 42 8 SO-NB-G80 Part Numbers PV2R2 PV2R3 ISD 30 42 8 ISD 35 55 11 SO-NB-G105 SO-NB-G135 SO-NB-G60 SO-NB-G30 SO-NB-G85 SO-NB-P46 SO-NB-G115 SO-NB-A231 6004 6205 6207 Note: 1) Item Nos. are used. When ordering seals. Please contact us."PV2R" Series Fixed Displacement .Single PV2R1/PV2R2/PV2R3/PV2R4 VANE PUMPS Spare Parts Lists PV2R1-∗-∗-RAA-40/4090 PV2R2-∗-∗-RAA-40/4090 PV2R3-∗-∗-RAA-30/3090 PV2R4-∗-∗-RAA-30/3090 CAUTION When making replacement of seals. beanings or cartridge kits. please do it carefully after reading through the relevant instructions in the Operator's Manual. please specify the kit number from the table right. . 12 14. 47 53.. 94 116 PV2R23 41. 94 116 136. 76 94. 59 65 52. 153 184.. 94 116 PV2R14 6. 8 10.18 40 30 2 . 8 10. 17 19.... N. 23 25. 76 94. 33 41. 23 PV2R24 26. 17 19. Japanese Standard "JIS" and European Design Standard 90 .. 12 14.. 200 237 -R A A A -40 ∗ Direction of Rotation Small Volume Pump Discharge Port Position Large Volume Pump Discharge Port Position Suction Port Position Design Number Design Standards (Viewed from Shaft End) E: Left 45° Upwards (Normal) A: Upwards (Normal) L: Foot Mtg. 33 41.. 60 66.. 12 14. Available to supply pump with anti-clockwise rotation.. Consult Yuken for details... 60 66.. 2."PV2R" SERIES Fixed Displacement . 47 53. Design Standards: None . 8 10. 23 25. 31 26. 116 76.. 31 76. E: Left 45° Upwards (Normal) A: Upwards (Normal) A: Upwards (Normal) 40 A: Upwards (Normal) A: Upwards (Normal) 40 Refer to 30 30 30 E: Left 45° Upwards (Normal) 1. American Design Standard No.. 47 PV2R34 52. 59 65 PV2R13 6.Double PV2R12/PV2R13/PV2R23/PV2R33/ PV2R14/PV2R24/PV2R34 VANE PUMPS Model Number Designation Graphic Symbols Model Number Designation FSpecial Seals F: Special seals for phosphate ester type fluids (Omit if not required) PV2R13 Series Number -6 -76 -L Large Small Volume Volume Pump Pump Mounting Nominal Nominal Displacement Displacement cm3/rev cm3/rev PV2R12 6.... 116 PV2R33 76... R: 1 Clockwise (Normal) F: Flange Mtg. 17 19.... 184. For the brands of anti-wear water-glycols. 94 116 HP 160 136. 33. the maximum operating pressure is limited to 16 MPa (2320 PSI). 33 Small 41 Volume 47 Pump 53 59 65 52 60 66 76 94 116 52.26 ment. see the item of "Hydraulic Fluids" on page 3. 3. Large Volume Pump 26. Operating Pressure Nominal Displacement Petroleum Base Oils cm3/rev Anti-Wear Type 6 8 10 12 14 17 19 21 2 (3050) 23 MPa (PSI) Water Containing Fluids R & O Type Anti-Wear Type Water Glycols 16 (2320) Synthetic Fluids 1 Water Glycols Water in Oil Emulsions Phosphate Esters 16 (2320) 7 (1020) 7 (1020) 16 (2320) 14 (2030) 16 (2320) 7 (1020) 7 (1020) 14 (2030) 14 (2030) 16 (2320) 7 (1020) 7 (1020) 14 (2030) 14 (2030) 16 (2320) 7 (1020) 7 (1020) 14 (2030) 21 (3050) 3 25 31 26 33 41 47 53 59 65 52 60 66 76 94 21 (3050) 21 (3050) 16 (2320) 3 21 (3050) 21 (3050) 116 16 (2320) 136 153 184 200 237 17. 237 140 kW 120 100 PV2R33 120 PV2R14 PV2R12 PV2R13 Input Power 6 8 10 12 14 17 19 23 25 Nominal 31 Displace. No. 53.Double PV2R12/PV2R13/PV2R23/PV2R33/ PV2R14/PV2R24/PV2R34 VANE PUMPS Specifications Specifications Maximum Operating Pressure Max. and nominal displacement. raise the speed over 1450 r/min. 59. 2) As for PV2R12 and PV2R33 series. 2. 153. the sum of the input powers to small volume pump and large volume pump is limited against shaft speed as follows."PV2R" Series Fixed Displacement . 200. see the table below. 60 66 100 80 60 80 60 Allowable Range 40 Allowable Range 40 PV2R24 20 0 PV2R23 20 0 600 1000 1200 Shaft Speed PV2R34 PV2R33 PV2R12 1500 1800 r/min 1. 41. 65 76.5 (2540) Note: 1) For the relation between model (series) No. If nominal displacement "23". Nominal Displacement.19 B . For pressures above 16 MPa (2320 PSI). of the PV2R14 series is selected. 47. the maximum speed is limited to 1500 r/min.9) -13 (3. the minimum suction pressure is -20 kPa (5. refer to pages 29&30. refer to page 15.20 Approx.13.6 (101) 51 (113) 84 (185) 75 (165) 78 (172) 98 (216) Foot Mtg. However. Same as single pump "PV2R3". 2. the maximum viscosity is limited. However. However. PV2R24 Same as single pump "PV2R2".94) PV2R12 Same as single pump "PV2R2".97) -20 (5. refer to page 15.6) 55. PV2R23 Same as single pump "PV2R2". Same as single pump "PV2R3". refer to page 15. refer to page 29."PV2R" Series Fixed Displacement . Hg vacuum) irrespective of speed. Suction Pres.6 (123) 61 (135) 94 (207) 100 (221) 103 (227) 123 (271) Mounting No.1) 45. [For other models.13. refer to pages 15&16. "60" and "66". Same as single pump "PV2R3". -20 (5. refer to pages 13&14. refer to pages 13&14.9) Large Volume Pump Same as single pump "PV2R1". refer to page 15. as for displacement of "26" and "33".9 in. PV2R34 Same as single pump "PV2R4". 25 (55.Double PV2R12/PV2R13/PV2R23/PV2R33/ PV2R14/PV2R24/PV2R34 VANE PUMPS Specifications Shaft Speed Range Shaft Speed Range Model Numbers PV2R12 PV2R13 PV2R23 PV2R33 PV2R14 PV2R24 PV2R34 Water Containing Fluids Phosphate Esters Petroleum Base Oils Max.1800 r/min -20 (5. refer to pages 11 . refer to page 29.9) 0 (0) -20 (5. as for displacement of "52". as for displacement of "52". 29. Same as single pump "PV2R3". as for displacement of "26" and "33".3 (64.) PV2R12 PV2R13 PV2R23 PV2R33 PV2R14 PV2R24 PV2R34 Flange Mtg. refer to pages 29&30. PV2R13 Same as single pump "PV2R1". For starting at low speed. 3 kPa (in. For details. see the item of "Hydraulic Fluids" on page 3. 750 750 600 2 2 r/min 3 3 3 Max.9) -7 (1. PV2R14 Same as single pump "PV2R1". refer to pages 11 . PV2R33 Same as single pump "PV2R3". Mass . the minimum suction pressure are limited in relation to the shaft speed.9) Output Flow & Input Power Small Volume Pump 3 1.13. refer to page 15. Model Numbers Model Numbers 3 2 1 Output Flow & Input Power The pump characteristics are the same as those for PV2R series single pumps. 3. 1200 1200 1200 Min. For PV2R33-116-116. 1800 1800 1800 1800 (1500) 1800 1800 1800 Min. 750 750 600 1200 600 1200 1200 1200 750 600 600 3 600 2 750 600 600 2 2 3 3 PV2R13-∗-116 PV2R23-∗-116 PV2R23-∗-76 PV2R23-∗-94 PV2R33-∗-76 PV2R33-94-∗ PV2R33-116-∗ PV2R33-∗-94 PV2R33-∗-116 PV2R14-∗-237 PV2R24-∗-237 PV2R34-∗-237 PV2R34-116-∗ Less than 1700 r/min 1700 . Hg Vacuum) 0 (0) 0 (0) -20 (5. refer to pages 11 . refer to pages 13&14. See the pages concerned. Mass Model Numbers kg (lbs. As for the models (nominal displacements) listed below. "60" and "66". 3 Min. However. Double PV2R12/PV2R13/PV2R23/PV2R33/ PV2R14/PV2R24/PV2R34 VANE PUMPS Pipe Flange Kits Pipe Flange Kits Pipe flange kits are available. American European Japanese Design European Design European Design Design Standard "JIS" Design Design Standard Standard Standard Standard Standard Standard F5-16-A-10 F5-16-A-1080 F5-16-A-1090 F5-16-B-10 F5-16-B-1090 F5-16-C-10 F5-16-C-1090 Suction F5-28-A-10 F5-28-B-10 F5-28-B-1090 F5-28-C-10 F5-28-C-1090 Large Discharge F5-12-A-10 F5-12-A-1080 F5-12-A-1090 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090 Small Discharge F5-04-A-10 F5-04-A-1080 F5-04-A-1090 F5-04-B-10 F5-04-B-1090 F5-04-C-10 F5-04-C-1090 Suction F5-28-A-10 F5-28-B-10 F5-28-B-1090 F5-28-C-10 F5-28-C-1090 Large Discharge F5-12-A-10 F5-12-A-1080 F5-12-A-1090 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090 Small Discharge F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090 Suction F5-32-A-10 F5-32-B-10 F5-32-B-1090 F5-32-C-10 F5-32-C-1090 Large Discharge F5-12-A-10 F5-12-A-1080 F5-12-A-1090 F5-12-B-10 F5-12-B-1090 F5-12-C-10 F5-12-C-1090 Small Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090 In case of using socket welding flanges. Pipe Flange Kit Numbers Threaded Connection Socket Welding Butt Welding Pump Model Numbers Name of Port PV2R12 Large Discharge F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090 Small Discharge F5-04-A-10 F5-04-A-1080 F5-04-A-1090 F5-04-B-10 F5-04-B-1090 F5-04-C-10 F5-04-C-1090 Suction F5-24-A-10 F5-24-B-10 F5-24-B-1090 F5-24-C-10 F5-24-C-1090 Large Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090 Small Discharge F5-04-A-10 F5-04-A-1080 F5-04-A-1090 F5-04-B-10 F5-04-B-1090 F5-04-C-10 F5-04-C-1090 Suction F5-24-A-10 F5-24-B-10 F5-24-B-1090 F5-24-C-10 F5-24-C-1090 Large Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090 Small Discharge F5-06-A-10 F5-06-A-1080 F5-06-A-1090 F5-06-B-10 F5-06-B-1090 F5-06-C-10 F5-06-C-1090 Suction F5-28-A-10 F5-28-B-10 F5-28-B-1090 F5-28-C-10 F5-28-C-1090 Large Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090 Small Discharge F5-10-A-10 F5-10-A-1080 F5-10-A-1090 F5-10-B-10 F5-10-B-1090 F5-10-C-10 F5-10-C-1090 Suction PV2R13 PV2R23 PV2R33 PV2R14 PV2R24 PV2R34 Japanese Japanese N. When ordering.21 B . there is a case where the operating pressure should be set lower than the normal because of strength of the flanges. please pay cautious attention to the operating pressure when the socket welding flanges are used. No. EC-3001. Notes: Special seals (Viton seals) are required when phosphate ester type fluids are used. American Standard "JIS" N. Therefore."PV2R" Series Fixed Displacement . Pub. specify the kit the number from the table below. American Standard "JIS" N.) Details of the pipe flange kits are given in the Catalogue No. (Prefix "F-" to the pipe flange kit number when ordering. 92) R14 (R.6 17.9988) 28.85) 120 (4.35 Key Width (.40( 1.5(.362) (3.063) 49(1.63) 75 (2.5(2.72) 95 (3.6 (1.102) "C" Thd.39) R9(R.17) 40 (1.10) Dia.31) "E" Thd.23) 47 115 (4.8 (3.98) 125 Sq.59) Dia.: PV2R12-∗-∗-L-REAA-40/4090 14(.22 40(1. 189(7.689) 58 8) . Through 28(1.".0000) Dia. 101.38 6.72) Dimensions mm (Inches) J K M8 19 (.59) 102 (4.18(1.2 (2 25. "J" Deep 4 Places No.000) (3.83) Dia.35) 77.2512) (.85) 146 (5.57) 143 (5.76) 95 (3.95) 326 (12.64) 55 (2.: PV2R12-∗-∗-F-REAA-40/4090 .874) Small Volume Pump Discharge Port 15(. Through 2 Places Model Numbers PV2R12-∗-∗-F-REAA-40 PV2R12-∗-∗-F-REAA-4090 "C" Thd.8 2) q.75) 14 (.67) Deep 4 Places 22.08) A 174 (6.740) 95 (3.02) A 3 (.998) 70 (2. (.Type "PV2R12" VANE PUMPS Installation Drawing 6.12) 326 (12.44) 42.55 (4.83) 129 80 (5.37( .06) For other dimensions.74) 15 (.55) 5/16-18 UNC 21 (.35) (1. "K" Deep 4 Places (3 9 7 S .57) 47. refer to "Flange Mtg. 17(.531) Dia.740) 230 (9. (4.63) DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.551) Dia.109) 28.55) 13.50 (1 Large Volume Pump Discharge Port 21(. Suction Port 53. 89 5 ) Flange Mtg.63) . "E" Thd.874) 60 82 (2. M12 M10 1/2-13 UNC 3/8-16 UNC 120 (4.0 Suction Port and Large Volume Pump Discharge Port Position 25 (.83) 80 129 (3.354) R10 (R.11) Dia.15) (5.08) (3.2 (. 16 (.93) E Small Volume Pump Discharge Port Position 78 ) 7 (3."PV2R" Series Double Pump .1 0) 38 . Spotface 4 Places 95 (3.15) View Arrow X "D" Thd.60 Dia.9 (1.748) 101.2500) 9 (.74) 67 (2. "D" Thd. 25.83) 16 (.00(1. X R8(R. 08) 120.82) Sq.: PV2R13-∗-∗-L-RAAA-40/4090 17.79) 16 (.32(1.97) 217(8.20) 120.189) 97 (3.57) 58 (2. 21 (.55) 21 (.2 88 (3.95) 63 (2.83) "D" Thd.74) 183 (7.75) 19 (.5 (4. M16 M10 M8 PV2R13-∗-∗-F-RAAA-4090 5/8-11 UNC 7/16-14 UNC 5/16-18 UNC Dimensions G H 19 (. "E" Thd.5 (4. 23 (.".5(3.31) PV2R13-∗-∗-F-RAAA-40 "C" Thd.7 (2.54) A 2(. 65(2.5 (4.500) 40(1.59) R8(R.09) Dia.689) Dia.43) 38.437) 58.31) R11(R.83) 9 (.16) (1.3138) (.97 7.57) 115. Spotface 4 Places 112 (4. "D" Thd.00 Dia. Through 26(1.6 106.39) 181 (7.4 (4.000) (3.70(1.126) 127.41) 75 (2.83) 20 (.189) "C" Thd. "F" Deep 4 Places Port Position 31.95 (5. Suction Port 78.18) Dia.48) 40 (1.63) DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.23 .5(. 126.626) (4.55) 17.391) 35. refer to "Flange Mtg.46) 50 131 (5.91) Model Numbers 145 (5.1 (1.5 117.56) 7.41) 76.311) 118 ) 5 (4.57) 115.2480) 35. 31.22) 166 Sq.63) 31 (1. Through 2 Places 148(5.57) "E" Thd.74) 370 (14.75) 14 (.5 (4.74) 370 (14. "H" Deep 4 Places 17. "G" Deep 4 Places 30.71) 117.689) 61.54) R16 (R.383) A 213 (8.: PV2R13-∗-∗-F-RAAA-40/4090 Small Volume Pump Discharge Port 15(.Type "PV2R13" VANE PUMPS Installation Drawing B Flange Mtg.28) 95 (3.5(.55) mm (Inches) F 109.626) 274 (10.2500) Dia.3126) Large Volume Pump Discharge Port 30(1.59) Dia. (6. No.02) Dia.54) 112 (4.5 (.5 (4.000) (4."PV2R" Series Double Pump .354) R15 (R.75(1.14(1.94 Key Width (.998) 90 (3.5 (4.9 (2.689) Dia.79) For other dimensions.2 (1. 70(1.75) 3/8-16 UNC 21 (.2500) Dia.83) Dia.59) 31.79) For other dimensions.7 (2. "J" Thd. Through 2 Places "C" Thd.2480) 35.7 6) 30.626) (4.87) 115.24 mm (Inches) M10 2(.41) 76.08) 139.3126) Flange Mtg.00 Dia. Through 26(1.354) Sq .55) 148 (5.437) "C" Thd. 31.09) Dia.93) "D" Thd.67) Deep 4 Places R11 (R.5 117.000) (4.689) Dia.5 (4.95) 31 (1.689) Dia.9 (2.75) 19 (.626) 274 (10.8 E 5 12 92) .22) 403 (15.2 ) 22 74 (.57) A R16 (R.4 (4. X "J" Thd.20) Small Volume Pump Discharge Port Position 118 ) 5 (4.87) 115.83) 109.43) 65 (2.02) Dia.75(1.189) R15 (R.54) 95 (3.189) 112 (4.5(.74) 63 (2.998) 90 (3.6 4) 47 .000) (3. Spotface 4 Places 112 (4.311) 61.71) 117.5 (4.91) 139.41) View Arrow X 213 (8.97) A 145 (5. 17(.126) 127.3138) (.79) DIMENSIONS IN MILLIMETRES (INCHES) 17.391) 35.: PV2R23-∗-∗-L-REAA-40/4090 403 (15. refer to "Flange Mtg.5 (5. "K" Deep 4 Places 183 (7.: PV2R23-∗-∗-F-REAA-40/4090 .6 Small Volume Pump Discharge Port 21(.56) .49) Dimensions K Foot Mtg.5 (5. R9(R.5 (4.2 (1. 126.94 Key Width (. 7. "L" Deep 4 Places (2 70 .5(3.49) .Type "PV2R23" VANE PUMPS Installation Drawing 21 (.95 (5.63) 17.97 7.".83) 20 (.5(.18) Dia.48) 40 (1.55) 23 (.54) 75 (2. (4 58.35) 49(1.32(1.87 (1 106. M16 M10 5/8-11 UNC 7/16-14 UNC PV2R23-∗-∗-F-REAA-40 PV2R23-∗-∗-F-REAA-4090 L 19 (.383) Suction Port 78.54) Large Volume Pump Discharge Port 21(1.5 (4.14(1.2 88 (3. No. 217(8.46) 50 131 (5.31) Model Numbers Suction Port and Large Volume Pump Discharge Port Position 166 (6."PV2R" Series Double Pump .16) (1.39) 181 (7.83) 9 (. "D" Thd. ".7 (2. 21 9 (.83) Model Numbers "C" Thd.689) Dia.35) 95 (3. R17 (R.74) 90 (3.189) 120.75) 19 (.3126) Flange Mtg.35) 17.10) Dia.10) Dia.79) For other dimensions.54) 124 (4.91) 454(17. 126.75(1. Through 26(1. "D" Thd.000) (4.689) Dia.94) 62 131 (5.35) 2 (. "F" Deep 4 Places 454(17.97 7.: PV2R33-∗-∗-L-RAAA-30/3090 76.67) R11 (R.83) (.Type "PV2R33" VANE PUMPS Installation Drawing B Large Volume Pump Discharge Port 28(1.5(.391) 35.: PV2R33-∗-∗-F-RAAA-30/3090 30.88) 87 (3.189) "D" Thd.2 100 (3.752) 30.46) Dia.383) 124 (4. "F" Deep 4 Places "C" Thd.87) 145 (5.43) 75 (2.626) (4.54) Sq.25 .32(1. M16 M10 PV2R33-∗-∗-F-RAAA-30 PV2R33-∗-∗-F-RAAA-3090 Dimensions mm (Inches) 5/8-11 UNC 7/16-14 UNC E F 19 (. refer to "Flange Mtg.126) 31 (1.5 117.54) 127.626) 274(10.2500) 31.95 (5.00 Dia.7 (2.43) 65(2. No.94 Key Width (.43) R11(R.2 (1. 7.31) 136 (5.02) Dia. Through 2 Places 148 (5.311) 3 12 4) 8 (4 .5 (4.311) Small Volume Pump Discharge Port 28(1.20) 31.5 (4.39) 181(7.2480) Dia.56) 58.22) 166(6.2 (1.14(1.354) Suction Port 88(3.75) 21 (.95) 56 (2. 136 (5.88) 109.20) 136 (5.752) 65(2.79) DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.54) 183(7. Spotface 4 Places 23(."PV2R" Series Double Pump .70(1.000) (3.3138) (.5(.71) 117.08) 136 (5.44) 217(8.35) 17.16) (2.9 (2.998) 90 35.7 (4. 69.87) Port Position A 213(8.63) (3. R16 (R. "E" Deep 4 Places "D" Thd.83) 20 (.56) 58. 000) 228.000) "C" Thd.Type "PV2R14" VANE PUMPS Installation Drawing Flange Mtg.28) (2.10(1.374) (7. Spotface (From Rear) 4 Places Model Numbers PV2R14-∗-∗-F-RAAA-30 R22 (R.56 9.36) 280(11.5(.53 Key Width (.406) R37(R1.37) 327.3 99 (4.998) 140 (5.89) 135 (5.752) 97 Sq. Through 43(1.5 (5.20) A 273(10. 21. (3.866) Dia. 9.5 (4.7 (1. 69.5 146.83) 16 (.65) 119.374) 438(17."PV2R" Series Double Pump .53) 58 (2.: PV2R14-∗-∗-L-RAAA-30/3090 . Through 39(1.752) R17 (R.3 (7.05(1.51) Dia.3(12.9 (2.82) 38.46) 146.9 (2.35 (6.83) 21 (.500) R8(R.77) R13 (R.6(9.8 69.67) 13 (. "F" Deep 4 Places 152. Spotface 4 Places 3(.51) 423(16.70) Port Position 135 (5.846) Dia.18) Foot Mtg. "D" Thd.75) Sq.6(9.5 (.: PV2R14-∗-∗-F-RAAA-30/3090 Large Volume Pump Discharge Port 36(1.7 17.689) "D" Thd.99) 115 (4. F H J M16 M12 M8 19 (.90) 60 185 (7.668) 42.70) (5.31) 92 (3. Small Volume Pump Discharge Port 13(.75) 14 (.36(1.661) 40(1.51) "E" Thd.54) 56 (2.5 (4. 152.24) For other dimensions.3 (7.77) 30(1.40 Dia.55) 1/2-13 UNC 5/16-18 UNC 21 (.69) Dia.65) 119.02) 187.".3752) Suction Port 88(3. 228. refer to "Flange Mtg.3 187. "E" Thd.18(1.5000) 38.75) 19 (.42) Dia.54) Dia.98) 123 ) 4 (4. "H" Deep 4 Places 35.000) (5.62) 76 (2.46) Dia.26 187. "J" Deep 4 Places 42.4980) Dia.500) (3. No.12) 423(16.28) 217(8.752) 120.87) Dimensions mm (Inches) "C" Thd.512) 25 (.31) 38.57) (4.1 (1.3764) (.31) 22(.63) PV2R14-∗-∗-F-RAAA-3090 5/8-11 UNC DIMENSIONS IN MILLIMETRES (INCHES) A 114. 7 (4.752) 120. "H" Deep 4 Places 35.10(1.8 69. R17 (R.512) 25 (.36) 187.89) 135 (5.874) 4 Places "C" Thd.75) 5/8-11 UNC 1/2-13 UNC 3/8-16 UNC 21 (.866) Dia.752) 47.53) 70 (2.62) 76 (2.31) 22(.18(1.000) 135 (5.83) 21.35 (6.6(9. (4.3 (7.5 171. refer to "Flange Mtg.3752) Suction Port 88(3. 17(.6(9.5(.05(1.874) 49(1.000) (5.5 (4.5000) Dia.5 171.02) 187. 38.98) 9.83) 21 (.: PV2R24-∗-∗-L-RAAA-30/3090 280(11.3764) (. Spotface 4 Places 3(.20) A 273(10.846) Dia.998) 140 (5.661) 22.76) 217(8.75) Sq. "E" Thd.42) Dia.752) 13 (. Through 43(1.37) 327.53 Key Width (.374) 438(17.56 9.69) Dia.67) 69.500) (3.19) 119.18) Foot Mtg. 228.87) DIMENSIONS IN MILLIMETRES (INCHES) A 99 114.27 .93) "D" Thd.70) (6.75) 19 (.: PV2R24-∗-∗-F-RAAA-30/3090 Large Volume Pump Discharge Port 36(1.99) 152.9 (2.Type "PV2R24" VANE PUMPS Installation Drawing B Flange Mtg.374) (7.28) (2.24) For other dimensions.".3 (7. Small Volume Pump Discharge Port 19(.5 (4.75) Dia.83) PV2R24-∗-∗-F-RAAA-30 PV2R24-∗-∗-F-RAAA-3090 R22 (R. "D" Thd.6 (1.31) 92 (3.19) 119. Spotface (From Rear) 4 Places Model Numbers Dimensions mm (Inches) "C" Thd.54) Dia. 152.67) Deep (."PV2R" Series Double Pump .46) Port Position 115 (4.36(1.70) (6.000) 228.92) R9(R.7 (1. 123 ) 4 (4.40 Dia.406) R13(R.90) 185 60 (7. F H M16 M12 M10 19 (.668) 42. No.54) 56 (2.12) 462(18.3 (4.51) 462(18.3 187. "F" Deep 4 Places 38.46) Dia.75) 30(1.51) R37(R1.4980) 125 Sq.9 (2.3(12. Through 39(1.75) 42.2 "E" Thd. "PV2R" Series Double Pump - Type "PV2R34" VANE PUMPS Installation Drawing Flange Mtg.: PV2R34-∗-∗-F-REAA-30/3090 Large Volume Pump Discharge Port 36(1.42) Dia. 6 16 54) . 6 ( "J" Thd. "N" Deep 4 Places 65(2.56) 152 8) (5.9 69.9 (2.752) Small Volume Pump Discharge Port 28(1.10) Dia. 130.2 (5.126) R17(R.67) R11(R.43) .2 ) 30 189 . (1 E Sq . 13 (.512) 9.56 9.53 Key Width (.3764) (.3752) 25 (.98) Small Volume Pump Discharge Port Position .7 ) 58 311 . (2 Suction Port 77.8 100(3.94) Dia. (3.063) "C" Thd. "K" Deep 4 Places "D" Thd. "L" Deep 4 Places 35.7 (1.406) R13(R.51) R37(R1.46) 90 4) .5 (3 H View Arrow X 518(20.39) 135 (5.31) Suction Port and Large Volume A Pump Discharge Port Position 273(10.75) Sq. 228.6(9.000) 228.6(9.000) X 115 (4.53) 92 (3.62) 76 (2.99) 56 (2.20) 152.40 Dia. 152.35 (6.000) (5.998) 140 (5.51) 133 (5.24) 38.10(1.5000) 38.05(1.4980) Dia. 42.36(1.668) 42.18(1.661) 192 (7.56) 21.5(.846) Dia. Through 39(1.54) Dia. Spotface (From Rear) 4 Places PV2R34-∗-∗-F-REAA-3090 "D" Thd. "J" Thd. K L N M16 M12 M8 19 (.75) 19 (.75) 19 (.75) 5/8-11 UNC 1/2-14 UNC 7/16-14 UNC 21 (.83) 21 (.83) 20 (.79) DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.: PV2R34-∗-∗-L-REAA-30/3090 135 (5.31) 22(.866) Dia. Through 43(1.69) Dia. Spotface 4 Places A 3(.12) 518(20.39) 133 192 (5.24) (7.56) 114.3 99 (4.500) (3.90) 185 60 (7.28) (2.36) 280(11.02) 187.3 187.3 (7.374) (7.374) 438(17.24) For other dimensions, refer to "Flange Mtg.". No.28 187.3 (7.37) 327.3(12.89) PV2R34-∗-∗-F-REAA-30 Dimensions mm (Inches) "C" Thd. 30(1.18) Model Numbers R22(R.87) "PV2R" Series Double Pump Type "PV2R12,PV2R23,PV2R24 & PV2R34" VANE PUMPS Typical Pump Characteristics Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)] PV2R12-∗-26 PV2R24-26-∗ 14 1200 r/min 30 kW 20 10 HP 30 20 10 0 L/min 110 3.5 10 6 30 kW 30 20 20 10 0 0 MPa 7 10.5 14 17.5 21 (1000) (2000) (3000) (PSI) 0 3.5 Pressure PV2R23-∗-52 PV2R34-52-∗ PV2R23-∗-60 PV2R34-60-∗ U.S.GPM 30 26 Output Flow 1500 r/min 70 60 1200 r/min 50 40 1000 r/min 30 1800 r/min 100 90 1800 r/min 80 L/min 110 kW 40 30 20 80 18 70 1500 r/min 1200 r/min 60 14 50 10 40 1000 r/min kW 50 30 HP 50 40 40 30 30 20 10 22 3.5 Pressure 50 40 30 20 10 10 0 MPa 7 10.5 14 17.5 21 (1000) (2000) (3000) (PSI) HP 60 20 10 0 0 0 10 0 0 MPa 7 10.5 14 17.5 21 (1000) (2000) (3000) (PSI) Pressure 90 HP 40 30 Input Power Output Flow 1200 r/min 20 100 8 40 Input Power 4 12 10 8 20 16 1500 r/min 12 1000 r/min 6 20 50 Input Power 1500 r/min 1000 r/min 24 1800 r/min Input Power Output Flow 40 U.S.GPM 28 L/min 60 1800 r/min 10 8 U.S.GPM 16 L/min 50 Output Flow U.S.GPM 13 12 PV2R12-∗-33 PV2R24-33-∗ 0 3.5 0 MPa 7 10.5 14 17.5 21 (1000) (2000) (3000) (PSI) Pressure No.29 B "PV2R" Series Double Pump-Type "PV2R23 & PV2R34" Typical Pump Characteristics Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)] PV2R23-∗-66 PV2R34-66-∗ L/min 140 U.S.GPM 130 Output Flow 28 24 20 16 12 120 1800 r/min 110 100 1500 r/min 90 80 1200 r/min 70 1000 r/min 60 kW 50 60 40 50 HP 70 40 30 20 50 40 30 20 10 0 3.5 0 0 MPa 7 10.5 14 17.5 21 (1000) (2000) (3000) (PSI) Pressure No.30 10 Input Power 32 VANE PUMPS Pump Model Numbers PV2R12-∗-∗-REAA-40∗ PV2R13-∗-∗-RAAA-40∗ PV2R23-∗-∗-REAA-40∗ PV2R33-∗-∗-RAAA-30∗ PV2R33 ISD 35 55 11 SO-NB-G135 SO-NB-G135 SO-NB-G115 SO-NB-A231 SO-NB-G115 SO-NB-A231 6207 6305 Qty.-∗-RAAA-40∗ PV2R13-8.-∗-REAA-40∗ 5 Large Volume Pump CPV2R13-6-L-40 CPV2R13-8-L-40 CPV2R13-10-L-40 CPV2R13-12-L-40 CPV2R13-14-L-40 CPV2R13-17-L-40 CPV2R13-19-L-40 CPV2R13-23-L-40 CPV2R13-25-L-40 CPV2R13-31-L-40 CPV2R23-41-L-40 CPV2R23-47-L-40 CPV2R23-53-L-40 CPV2R23-59-L-40 CPV2R23-65-L-40 CPV2R2 .-∗-REAA-40∗ PV2R23-65. Referring to the model No.-∗-RAAA-40∗ PV2R13-31. bearing or cartridge kits.-∗-REAA-40∗ PV2R12-8.-∗-REAA-40∗ PV2R12-19.-∗-REAA-40∗ PV2R12-31.-∗-RAAA-40∗ PV2R13-25.-∗-REAA-40∗ PV2R23-53. When ordering seals. please specify the seal kit number from the table right. Please contact us.-∗-REAA-40∗ PV2R23-47.31 B . Nos.-R-30 CPV2R33 .-∗-RAAA-40∗ PV2R13-12.-∗-REAA-40∗ PV2R12-25.-∗-RAAA-40∗ PV2R13-19. PV2R23 & PV2R33" VANE PUMPS Spare Parts List PV2R12-∗-∗-∗-REAA-40/4090 PV2R13-∗-∗-∗-RAAA-40/4090 PV2R23-∗-∗-∗-REAA-40/4090 PV2R33-∗-∗-∗-RAAA-30/3090 3 15 14 CAUTION When making replacement of seals.-∗-RAAA-40∗ PV2R13-10.-∗-REAA-40∗ PV2R12-10. 10 and 11 are included in the large volume pump cartridge kit and those under item.-∗-RAAA-40∗ PV2R33-76.-∗-RAAA-30∗ 6 Small Volume Pump 5 Large Volume Pump CPV2R13-6-L-40 CPV2R13-8-L-40 CPV2R13-10-L-40 CPV2R13-12-L-40 CPV2R13-14-L-40 CPV2R13-17-L-40 CPV2R13-19-L-40 CPV2R13-23-L-40 CPV2R13-25-L-40 CPV2R13-31-L-40 CPV2R33-76-L-30 CPV2R33-94-L-30 CPV2R33-116-L-30 CPV2R3 . 14 and 15 in the small volume pump cartridge kit. 1 1 1 1 1 1 1 1 1 Seal Kit Numbers KS-PV2R12-40 KS-PV2R13-40 KS-PV2R23-40 KS-PV2R33-30 No. write the correct nominal displacement figures.-∗-REAA-40∗ PV2R12-17.-∗-RAAA-40∗ PV2R13-17.-R-40 CPV2R3 .-∗-REAA-40∗ PV2R23-41.-∗-RAAA-30∗ PV2R33-94. Seals & Bearings Item Name of Parts 7 8 9 10 11 14 15 18 19 Oil Seal O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring Bearing Bearing PV2R12 ISD 30 42 8 SO-NB-G105 SO-NB-G80 SO-NB-G85 SO-NB-P46 SO-NB-G60 SO-NB-G30 6205 Part Numbers PV2R13 PV2R23 ISD 35 55 11 ISD 35 55 11 SO-NB-G135 SO-NB-G135 SO-NB-G105 SO-NB-G80 SO-NB-G115 SO-NB-G115 SO-NB-A231 SO-NB-A231 SO-NB-G85 SO-NB-G60 SO-NB-P46 SO-NB-G30 6207 6207 Note: 1) The o-rings under item. are used."PV2R" Series Double Pump Type "PV2R12.-∗-RAAA-30∗ PV2R33-116.-∗-REAA-40∗ PV2R12-14.-∗-REAA-40∗ PV2R12-23. Nos.-∗-RAAA-40∗ PV2R13-23.-R-30 Model Numbers PV2R13-6.-∗-RAAA-40∗ PV2R13-14. PV2R13.-∗-REAA-40∗ PV2R12-12. different part Nos. 9 6 1 5 8 10 11 21 2 18 7 4 20 24 23 22 27 26 25 Cartridge Kits Cartridge Kit Numbers Cartridge Kit Numbers Model Numbers 6 Small Volume Pump PV2R12-6. designation on page 18. 2) For pumps for phosphate ester type hydraulic fluids.-∗-REAA-40∗ PV2R23-59.-R-30 Note: Each above is a space for large volume pump nominal displacement. please do it carefully after reading through the relevant instructions in the Operator's Manual. 3 25 21 20 13 6 29 1 10 9 5 12 18 16 2 17 19 35 27 24 11 26 4 8 15 14 7 33 32 34 31 30 28 36 Cartridge Kits Cartridge Kit Numbers Model Numbers PV2R14-6.-∗-RAAA-30∗ PV2R24-33.-∗-REAA-30∗ PV2R34-116. Seal Kit Numbers KS-PV2R14-30 KS-PV2R24-30 KS-PV2R34-30 1 1 1 1 1 1 1 1 1 1 1 1 1 .-∗-REAA-30∗ 5 Large Volume Pump CPV2R23-26-L-30 CPV2R23-33-L-30 CPV2R23-41-L-30 CPV2R23-47-L-30 CPV2R33-52-L-30 CPV2R33-60-L-30 CPV2R33-66-L-30 CPV2R33-76-L-30 CPV2R33-94-L-30 CPV2R33-116-L-30 CPV2R4 .-∗-RAAA-30∗ 6 Small Volume Pump CPV2R13-6-L-30 CPV2R13-8-L-30 CPV2R13-10-L-30 CPV2R13-12-L-30 CPV2R13-14-L-30 CPV2R13-17-L-30 CPV2R13-19-L-30 CPV2R13-23-L-30 5 Large Volume Pump CPV2R2 . When ordering seals.-∗-RAAA-30∗ PV2R14-23.-∗-RAAA-30∗ PV2R14-8.-∗-REAA-30∗ PV2R34-60. 16 to 19 are included in the large volume pump cartridge kit and those under item.-∗-RAAA-30∗ PV2R14-12."PV2R" Series Double Pump Type "PV2R14.-R-40 Note: The marks are spaces for large volume pump nominal displacements. bearing or cartridge kits.-∗-REAA-30∗ PV2R34-76. please specify the seal kit number from the table right.-∗-RAAA-30∗ PV2R14-19.-∗-RAAA-30∗ PV2R14-17.-∗-REAA-30∗ PV2R34-66. Nos.-∗-RAAA-30∗ PV2R34-52.-∗-RAAA-30∗ PV2R14-10. are used.-R-30 CPV2R34 .-∗-RAAA-30∗ PV2R24-41. Nos.-∗-RAAA-30∗ PV2R14-14. please do it carefully after reading through the relevant instructions in the Operator's Manual. different part Nos.-∗-RAAA-30∗ PV2R24-47. Cartridge Kit Numbers Model Numbers 6 Small Volume Pump PV2R24-26. 20 and 21 in the small volume pump cartridge kit.-∗-REAA-30∗ PV2R34-94. Referring to the model No. 2) For pumps for phosphate ester type hydraulic fluids.32 Part Numbers PV2R24 ISD 45 68 12 SO-NB-G145 SO-NB-G105 SO-NB-P28 SO-NB-P22A SO-NA-G130 SO-NA-G80 SO-BE-G130 SO-BB-G80 SO-NB-G85 SO-NB-P46 6209 Pump Model Numbers PV2R14-∗-∗-RAAA-30∗ PV2R24-∗-∗-RAAA-30∗ PV2R34-∗-∗-REAA-30∗ PV2R34 ISD 45 68 12 SO-NB-G145 SO-NB-G135 SO-NB-P28 SO-NB-P22A SO-NA-G130 SO-NA-G80 SO-BE-G130 SO-BB-G80 SO-NB-G115 SO-NB-A231 6209 6305 Qty. PV2R24 & PV2R34" VANE PUMPS Spare Parts List PV2R14-∗-∗-∗-RAAA-30/3090 PV2R24-∗-∗-∗-RAAA-30/3090 PV2R34-∗-∗-∗-REAA-30/3090 CAUTION When making replacement of seals. write correct nominal displacement figures. Please contact us. No. designation on page 18.-R-30 Seals & Bearings Item Name of Parts 11 12 13 14 15 16 17 18 19 20 21 24 25 Oil Seal O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring Back Up Ring Back Up Ring O-Ring O-Ring Bearing Bearing PV2R14 ISD 45 68 12 SO-NB-G145 SO-NB-G80 SO-NB-P28 SO-NB-P22A SO-NA-G130 SO-NA-G80 SO-BE-G130 SO-BB-G80 SO-NB-G60 SO-NB-G30 6209 Note: 1) The o-rings and back up rings under item. Graphic Symbol Model Number Designation FSpecial Seals F: For phosphate ester type fluids (Omit if not required) -L -R A A -20 ∗ Mounting Direction of Rotation Discharge Port Position Suction Port Position Design Number Design Std. EC-3001.. The excessive wear to the vanes and camring which usually occurs in shch high pressure vane pumps has been solved by means of adopting the special methods in both mechanical construction aspects and lubrication systems.IN. Design Standards: None.. specify the kit number from the table below. 15 19 22 F: Flange Mtg.Single PV11R10/PV11R20 B Up to 40 MPa (5800 PSI). PV11R20 (Viewed from Shaft End) 20 R: 1 Clockwise 1.). Available to supply pump with anti-clockwise rotation./rev) These pumps are of completely unique design for extra high pressure applications.349 CU. 22... A: Upwards (Normal) A: Upwards (Normal) Refer to 2 20 2. No. When ordering.1 . . American Design Standard F5-08-A-10 F5-08-A-1080 F5-08-A-1090 Pipe Flange Kit Numbers Socket Welding Japanese Standard "JIS" European Design Standard N.Pub.1 cm3/rev (1. EC-0119 "PV11R" SERIES VANE PUMPS Fixed Displacement. American Design Standard F5-08-C-10 F5-08-C-1090 Note: 1) Special seals (Viton seals) are required when phosphate ester type fluids are used (prefix "F-" to the pipe flange kit number when ordering. N. American Design Standard F5-08-B-1090 F5-08-B-10 F6-04W-B-M-10 F6-04W-B-U-1090 Butt Welding Japanese Standard "JIS" European Design Standard N. Consult Yuken for details.. .. Note: 2) Details specifications of pipe flange kits are given in the Catalogue No. PV11R10 -12 Series Number Nominal Displacement cm3/rev PV11R10 2 5 7 10 12 L: Foot Mtg..Japanese Standard "JIS" & European Design Standard 90 . American Design Sandard Pipe Flange Kits Pipe flange kits are available. Pub. Threaded Connection Pump Model Numbers Name of Port PV11R10 PV11R20 Suction Discharge Japanese Standard "JIS" European Design Standard N. .. . 275) (.7 12.349) Maximum Operating Pressure MPa(PSI) Water Containing Fluids 1 Anti-Wear 1 Water Water in Oil Type Water Glycols Emulsions Glycols Petroleum Base Oils Anti-Wear Type 31.0 22.738) (."PV11R" Series Single Pump-Type "PV11R10&PV11R20" Specifications VANE PUMPS Specifications Maximum Operating Pressure Model Numbers Geometric Displacement cm3/rev (CU. see the item of "Hydraulic Fluids" on page 3.2 19.2 Typical Pump Characteristics described on the Pages below 5.5 6.159) (1. 16.6 6 .915) (1. hold the speed above 1450 r/min.415) (.1 15.8) Output Flow & Input Power Characteristics are described on the pages as shown on the table below.2) 19.2 4.5 (4570) R&O Type Synthetic Fluids Phosphate Esters 2 40 (5800) 35 (5100) 25 (3630) 25 (3630) 7 (1020) 7 (1020) 25 (3630) 25 (3630) 25 (3630) 7 (1020) 7 (1020) 25 (3630) 1.2) 19.4 (42.8 9.4 (42. For the brands of anti-wear type water-glycols. Please see the pages concerned. Foot Mtg. For details. 2.4 (36. Shaft Speed Range Model Numbers Shaft Speed Range r /min Max.) Flange Mtg. For pressures above 25 MPa (3630 PSI).1 (.592) (. Petroleum Base Oils Anti-Wear Type PV11R10-2 PV11R10-5 PV11R10-7 PV11R10-10 PV11R10-12 PV11R20-∗ Synthetic Fluids R & O Type Water-Containing Fluids Phosphate Esters 1800 1200 1200 1800 1200 1200 Min. 3000 2500 2300 2000 1800 950 800 800 For starting at low speed.134) (. Mass kg(lbs./rev) PV11R10-2 PV11R10-5 PV11R10-7 PV11R10-10 PV11R10-12 PV11R20-15 PV11R20-19 PV11R20-22 2. see the item of "Hydraulic Fluids" on page 3. Model Numbers PV11R10 PV11R20 No.IN.4 (36.8) 16. the maximum viscosity is limited. Mass Model Numbers PV11R10 PV11R20 Approx. Viscosity mm2/s (SSU) 600 100 (455) 950 200 (910) 3.3 ft. Precautions at starting At an initial operation or at an operation after a long rest.8 metre (2. prefix "F-" Synthetic Fluids to the model number because the special seals (fluororubber) are required to be used. please refer to the specifications of the pump concerned. Carry out sufficient contamination control for hydraulic fluids and keep contamination level within NAS class 12.). For details. more than 50 mm (2 in. ST1004-∗-10∗. LTD. However. COSMO FLUID HQ 46 COSMO OIL CO. an air bleed valve should be installed beforehand on the discharge side (model No. EC-3001. Also. Catalogue No. Instructions 1.) from the oil level {less than 0. . use a 100 μm (150-mesh) tank filter on the suction side. Fluid viscosity and temperature Maximum viscosity for low start-up speed (Table 3) Temperature °C (°F) Fluid Petroleum Base Oils Phosphate Esters Water Glycols Water in Oil Emulsions Viscosity mm2/s(SSU) 0-70 (32-158) 0-50 (32-122) 5-50 (41-122) (Table 4) Pump Type PV11R10. In such cases. Hg Vacuum) Maximum +30 kPa (+4. 4. Suction pressures Set the suction pressure at pump inlet port at the value given in the table below. No.) in case of using phosphate ester fluids or water containing fluids}. Containing Fluids Water in Oil Standard pumps can be used without conditions. Emulsions Anti-wear type water-glycols (Table 2) Fluid Manufacturer Commercial Trade Name Mobil Hydrofluid HFC 46 Mobil Mobil Nybac FR 200 D JAPAN ENERGY CORP.) away from the tank bottom. Control of contamination Contamination of hydraulic fluids results in pump failures and reduced pump lives. (Table 5) Suction Pressure Model Numbers PV11R. When phosphate ester type fluid is used. and avoid any stress from bending or thrust. operate the pump intermittently as far as possible with no load.2°. the maximum fluid viscosity is limited. Type of hydraulic fluids (Table 1) Type of Fluids Descriptions Use anti-wear type oils or R&O type oils Petroleum Base Oils (equivalent to ISO VG32 or 46). PV11R20 Minimum Phosphate ester type fluid Petroleum base oil water containing fluid -20 kPa -16 kPa (5.1 mm (. Fluid viscosity and temperature Use the hydraulic fluids which satisfy the recommended viscosity and oil temperature given in the Table 3 below.3 PSIG) 3. Other precautions If a PV11R series single pump is used at speed below 1200 r/min. At starting. Hg Vacuum) (4. or discharge air by slightly slackening the connection on the discharge side. . Alignment of shaft Employ a flexible coupling whenever possible. use the pipes in the suction side having the diameter as indicated on the installation drawings. LTD HYRAND FRX 46 Irus Fluid C Showa Shell Sekiyu K. Water-Glycols However. However. PV11R20 20-400 (100-1800) Start-up Speed r/min Max. the height of the suction port of the pump should be less than 1 metre (3.004 inches) TIR and maximum permissible misangular is less than 0.6 ft. Pub. In case where the pump is installed on the tank or at the position higher than the tank top cover."PV11R" Series Single Pump-Type "PV11R10&PV11R20" Hydraulic Fluids & Instructions VANE PUMPS Hydraulic Fluids 1. the maximum operating pressure is limited. K. G-W Fluid 46 MATSUMURA OIL HYDOL HAW RESEARCH CORP.7 in. install the pump with the suction port upside so that the pump can suck up fluid easily at starting. COSMO FLUID GS 46 2. Standard pumps can be used without conditions. 2. Maximum permissible misalignment is less than 0.9 in. Use phosphate ester type fluids. JOMO Hydoria NIPPON OIL CO. see the item of "Hydraulic Fluids". please note that if any of the pumps listed in the Table 4 is started at low speed. For fluid viscosity at starting. the pump may have difficulty in sucking up fluid.3 B . Furthermore. if any type other than those in Table 2 is Water used. the specifications of the pumps such as maximum pressure and maximum pump speed may be changed according to the type of hydraulic fluids to be used. Type of hydraulic fluids Any type of hydraulic fluids listed in the Table 1 below can be used. 748) R14 (R. refer to "Flange Mtg. 17(.51) Dia.36) 52 (2.985) 24.4 . Spotface (From Rear) 2 Places DIMENSIONS IN MILLIMETRES (INCHES) Foot Mtg.51) 2(.26) 25(.2510) key Width Discharge Port 13(.94) Dia.8 77.63) 179.92) Sq.23(.38(.68) 92.45) For other dimensions.39) "A" Thd.01) 146(5.45) 68 (2."PV11R" Series Single Pump-Type "PV11R10&PV11R20" VANE PUMPS Installation Drawing Flange Mtg.57(3.874) 172(6. 9 (.87) 52.5 (1.83) Dia.60) A 50.5 (2.5(.43) Dia.77) 13(.874) (2.594) 73 (2.978) 22.35) 16 (.46) A 101.000) (3. No.86) 73 73 (2. Through 24(.78) (1. 101.85) 91.60(4.08) 68 (2.98) 62.717) 4 Places Port Position 91.55) Deep (. 18.60) 174(6. Through 21(.68) 40.39) 6.5 (2. 25.85) 51(2. M8 5/16-18 UNC 68 (2.9988) 243(9.67) Deep 4 Places 26.77) 98 (3.5 (5. PV11R10-∗-L-RAA-20/2090 PV11R20-∗-L-RAA-20/2090 11(. 14(.4 (2.0000) Dia.63) R10(R.98) Dia. Spotface 4 Places 174(6.85(.35(.2 "B" Thd.05) 243(9.2512) 6.1 (3.20(.53) Dia.063) R10 (R.05) 96 45 (3.2 (1.56) 32(1.55) 125(4.68) 120(4.031) 60 (2. M10 3/8-16 UNC "B" Thd.5 (3.02) 65 (2.8752) Dia.8740) 127.72) 13.05) Model Numbers PV11R10/PV11R20-∗-∗-RAA-20 PV11R10/PV11R20-∗-∗-RAA-2090 "A" Thd.".01(. PV11R10-∗-F-RAA-20/2090 PV11R20-∗-F-RAA-20/2090 Suction Port 25(.1(7. 20.5 (3. 8 7 1.0 1.5 .6 6 6 5 4 1000 r /min 8 10 8 6 4.GPM 1.1 U.6 1800 r /min 8 1 kW 4 3 3 2 1 1 0 0 0 10 20 25 30 31.0 2.4 .0 16 16 1500 r /min 14 HP 20 14 18 16 12 1200 r /min 12 10 1000 r /min 10 14 12 8 8 10 6 8 4 2 0 10 20 30 1000 2000 3000 4000 5000 5700 PSI Pressure 2 2 0 0 40 MPa 6 4 4 0 Input Power 4 .0 HP 5 4 2 U.2 PV11R10-5 L /min 5 0 0 0 10 20 30 2 0 40 MPa 1000 2000 3000 4000 5000 5700 PSI Pressure No.8 30 2.8 1.5 3.6 2.2 Output Flow . 50°C (122°F)] PV11R10-2 3 1800 r /min 1500 r /min 2 1200 r /min 1000 r /min .6 1.S.S.2 10 Pressure L /min 13 12 4 3 Output Flow 3.5 12 2.4 9 U.0 2.4 HP 10 1500 r /min 1.2 L /min 9 Input Power Output Flow U.GPM kW 8 2.5 MPa 1000 2000 3000 4000 4500 Pressure PSI 1.5 2."PV11R" Series Single Pump-Type "PV11R10" VANE PUMPS Typical Pump Characteristics B Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.0 1800 r /min 1000 2000 3000 4000 5000 5700 PSI L /min 20 18 1500 r /min kW 12 1200 r /min 8 0 0 40 MPa PV11R10-10 11 10 10 HP 16 14 1.GPM 2.GPM 5.S.4 20 1800 r /min kW 4.0 3.4 7 .8 Input Power 1.2 1.8 7 6 1200 r /min 5 4 6 4 2 2 1 0 0 Output Flow 2.S.2 8 6 1000 r/min PV11R10-7 3.0 5 3 0 Input Power 3. GPM L /min 7.5 Input Power Output Flow 20 Input Power L /min 22 PV11R20-15 U.0 4 0 0 6.S.S.5 4.5 28 10 5 4 0 0 0 0 10 20 30 35 40 MPa 1000 2000 3000 4000 5000 Pressure PSI 5 0 Input Power U.0 6.5 16 1200 r /min 14 kW 1000 r /min 12 HP 24 20 10 16 20 12 16 12 8 8 4 0 10 20 30 5.6 0 30 35 40 MPa PSI HP 40 35 25 20 Input Power 4 12 4 1000 2000 3000 4000 5000 5700 PSI L /min U.5 3.GPM 11 1800 r /min PV11R20-22 L /min 40 Output Flow 10 1500 r /min Output Flow 4 0 0 30 35 40 MPa 1000 2000 3000 4000 5000 Pressure 1200 r /min 1000 r /min kW HP 24 32 20 16 16 12 8 8 7 6 28 5 24 20 16 12 1800 r /min 36 9 1500 r /min 32 28 1200 r /min 24 kW 30 1000 r /min 30 20 25 20 15 15 10 8 4 0 0 10 20 1000 2000 3000 4000 5000 Pressure No.0 3."PV11R" Series Single Pump-Type "PV11R10&PV11R20" VANE PUMPS Typical Pump Characteristics Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils.0 2.5 7.5 16 20 14 12 16 12 8 1000 r /min 8 0 40 MPa 0 0 10 20 PSI Pressure PV11R20-19 U.0 1200 r /min 18 3. 50°C (122°F)] PV11R10-12 1800 r /min 5.5 24 1500 r /min 22 20 kW 5.S.5 Output Flow 1500 r /min 18 4.S.0 1800 r /min 26 4.0 5.0 .GPM 36 9 32 8 28 7 24 6 20 5 20 HP 28 24 16 4.GPM 6. No. please specify the seal kit number (Kit No. beanings or cartridge kits. 12 Oil Seal ISD 25 38 8 1 13 O-Ring SO-NB-G95 1 14 O-Ring SO-NB-G75 1 15 O-Ring SO-NB-P42 1 16 O-Ring SO-NB-P18 1 17 O-Ring SO-NB-P9 3 18 Back Up Ring SO-BE-G75 1 19 Back Up Ring SO-BB-P42 1 20 Bearing 6005 1 28 O-Ring SO-NB-P11 1 Notes: 1) Item Nos. CPV11R10-2-R-20 CPV11R10-5-R-20 CPV11R10-7-R-20 CPV11R10-10-R-20 CPV11R10-12-R-20 CPV11R20-15-R-20 CPV11R20-19-R-20 CPV11R20-22-R-20 Seals & Bearing Item Name of Parts Part Numbers PV11R10. Please contact us. PV11R10-∗-∗-RAA-20/2090 PV11R20-∗-∗-RAA-20/2090 8 16 9 24 10 11 25 26 24 23 24 17 2 3 13 18 14 15 19 6 7 20 1 12 A 5 4 27 28 22 A 21 Section A-A Cartridge Kits Model Numbers PV11R10-2-∗-RAA-20/2090 PV11R10-5-∗-RAA-20/2090 PV11R10-7-∗-RAA-20/2090 PV11R10-10-∗-RAA-20/2090 PV11R10-12-∗-RAA-20/2090 PV11R20-15-∗-RAA-20/2090 PV11R20-19-∗-RAA-20/2090 PV11R20-22-∗-RAA-20/2090 3 Cartridge Kit No. When ordering seals. PV11R20 Qty. 2) For pumps for phosphate ester type hydraulic fluids."PV11R" Series Single Pump-Type "PV11R10&PV11R20" VANE PUMPS Spare Parts List CAUTION When making replacement of seals. please do it carefully after reading through the relevant instructions in the Operator's Manual.: KS-PV11R10-20).7 B . 14 . 15 and 17 (o-rings) and 18 and 19 (back up rings) are included in the cartridge kit. different cartridge kit and seals from the above are used.
Copyright © 2024 DOKUMEN.SITE Inc.