York Furnace Manual

March 17, 2018 | Author: Toky100 | Category: Thermostat, Furnace, Heat Exchanger, Energy Technology, Mechanical Engineering


Comments



Description

277805-YTG-A-1106DESCRIPTION These Category IV, highly efficient, compact, condensing type furnaces are designed for residential and commercial installations in a basement, closet, alcove, recreation room or garage where the ambient temperature is above 32°F, or higher. They may be either side wall or thru-roof vented using approved plastic type combustion air and vent piping. All units are factory assembled, wired and tested to assure dependable and economical installation and operation. WARRANTY TECHNICAL GUIDE MODELS: GY9S-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92% TO 94% AFUE NATURAL GAS 40 - 135 MBH INPUT Lifetime limited warranty on both heat exchangers to the original purchaser; a 20-year limited warranty from original installation date to subsequent purchaser. 10-year warranty on the heat exchanger in commercial applications. 5-year limited parts warranty. FEATURES • • • • • • • • • • • • • • • • Compact, easy to install, ideal height 40" cabinet Blower-off delay for cooling SEER improvement. Easy to connect power/control wiring. Built-in, high level self diagnostics with fault code display. Low unit amp requirement for easy replacement application. Integrated control module for reliable, economical operation. May be installed as either two-pipe (sealed combustion) or single pipe vent (using indoor combustion air) Top intake & vent connection allows installation in narrow locations. Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. Induced combustion system with inshot main burners for quiet, efficient operation. No special vent termination kit required. 100% shut off main gas valve for extra safety. PSC four speed, direct drive motor with large, quiet blower. 24V, 40 VA control transformer and blower relay supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger. Secondary (condensing) heat exchanger of 29-4C highgrade stainless steel. Timed on, adjustable off blower capability for maximum comfort. Solid removable bottom panel allows easy application. Easy access from front of unit for cleaning, maintenance or service. Protection from intake, exhaust or condensate blockage. EFFICIENCY RATING CERTIFIED • • • ISO 9001 Certified Quality Management System • Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.gamanet.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE ) 13-1/4 16-1/4 16-1/4 19-3/4 19-3/4 19-3/4 19-3/4 23-1/4 23-1/4 C (in. CONDENSATE DRAIN 7/8” K. CONDENSATE DRAIN 7/8” K.) 14-1/2 17-1/2 17-1/2 21 21 21 21 24-1/2 24-1/2 B (in.O.O.) 11-1/2 14-1/2 14-1/2 18 18 18 18 21-1/2 21-1/2 D (in.) 6-1/4 8-1/2 8-1/2 8-7/8 8-7/8 8-7/8 8-7/8 10-5/8 10-5/8 2 Johnson Controls Unitary Products .O.277805-YTG-A-1106 28-1/2 26-1/2 24-5/8 1-1/2” GAS PIPE ENTRY 7/8” JUNCTION BOX HOLE T-STAT WIRING 7/8” K.O. OPTIONAL RETURN AIR CUT-OUT (either side) FOR USE WITH EXTERNAL FILTER FRAME 7/8 23-3/4 LEFT SIDE 26-1/2 A 25-3/8 1-1/2” GAS PIPE ENTRY 30-7/8 21-1/2 40 7/8” JUNCTION BOX HOLE 28-3/8 21-1/2 13-7/8 11 7 7/8 1-1/2 26-3/4 1-1/4 D C B 20 FRONT 24-3/8 5/8 5/8 11 8 T-STAT WIRING 7/8” K. RIGHT SIDE 2 BOTTOM IMAGE RETURN END 24-7/16 TOP IMAGE SUPPLY END Models GY9S040A12UP11 GY9S060B12UP11 GY9S080B12UP11 GY9S080C16UP11 GY9S080C20UP11 GY9S100C16UP11 GY9S100C20UP11 GY9S120D20UP11 GY9S135D20UP11 Nominal CFM 1200 1200 1200 1600 2000 1600 2000 2000 2000 Cabinet Size A B B C C C C D D Cabinet Dimension A (in. 3.7 12.75 40 . above sea level. reduce capacity 4% for each 1000 ft.0 92.65 40 .0 92.277805-YTG-A-1106 ELECTRICAL AND PERFORMANCE DATA Model GY9S040A12UP11 GY9S060B12UP11 GY9S080B12UP11 GY9S080C16UP11 GY9S080C20UP11 GY9S100C16UP11 GY9S100C20UP11 GY9S120D20UP11 GY9S135D20UP11 Input/ Cabinet MBH 40/A 60/B 80/B 80/C 80/C 100/C 100/C 120/D 135/D Input/ Cabinet MBH GY9S040A12UP11 GY9S060B12UP11 GY9S080B12UP11 GY9S080C16UP11 GY9S080C20UP11 GY9S100C16UP11 GY9S100C20UP11 GY9S120D20UP11 GY9S135D20UP11 40/A 60/B 80/B 80/C 80/C 100/C 100/C 120/D 135/D Output MBH 38 56 74 75 75 93 93 112 127 Max. For altitudes above 2000 ft.75 40 .0 92. 11 x 8 11 x 8 11 x 8 11 x 10 11 x 11 11 x 10 11 x 11 11 x 11 11 x 11 Total Unit Amps 9 9 9 12 14 12 14 14 14 Max. Wire Size (awg) @ 75 ft.0 10.0 7.0 7.70 45 . Rise °F 35 .c.75 Operating Wt Lbs. Wire size based on copper conductors. One Way 14 14 14 14 12 14 12 12 12 Air Temp.0 92.7 Nominal external static pressure is 0.0 92. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. 60°C. 3% voltage drop.70 45 . at furnace outlet ahead of cooling coils.2 12. Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Johnson Controls Unitary Products 3 .70 45 . °F 165 170 175 175 170 175 170 170 175 HP 1/2 1/2 1/2 3/4 1 3/4 1 1 1 Nominal Airflow CFM 1200 1200 1200 1600 2000 1600 2000 2000 2000 Cabinet Width In.70 40 . 2.7 12.50” w. 14-1/2 17-1/2 17-1/2 21 21 21 21 24-1/2 24-1/2 Blower Size In.0 92.0 92.2 12.0 Min. Over-current Protect 20 20 20 20 20 20 20 20 20 AFUE % 94. 119 133 140 155 157 160 162 178 178 Model Blower Amps 7. Outlet Air Temp. Continuous return air temperature must not be below 55°F.0 92. NOTES: 1.7 10.75 45 . 5 1415 1160 955 725 1465 1150 940 720 1930 1680 1390 1105 1830 1545 1310 975 2220 1885 1565 1085 0. Inches W. 2.1 2465 2085 1725 1420 2615 2055 1690 1345 0.0 1470 1235 995 845 1670 1470 1200 850 NOTES: 1.0 NR NR NR NR 1060 875 750 560 1350 1155 920 790 1485 1260 1070 850 1650 1405 1140 845 Airflow with Two Side Returns or with Bottom and One Side Return .277805-YTG-A-1106 BLOWER PERFORMANCE CFM Airflow with Bottom or One Side Return . 4 Johnson Controls Unitary Products .1 1635 1245 1005 775 1650 1165 895 710 2300 1950 1610 1325 1960 1565 1230 930 2560 2090 1695 1175 0. Airflow expressed in standard cubic feet per minute (CFM).3 2295 1960 1595 1310 2450 2015 1620 1335 0.without Filters (CFM) MODELS Speed Tap HIGH GY9S040A12UP11 M-HI M-LO LOW HIGH GY9S060B12UP11 GY9S080B12UP11 M-HI M-LO LOW HIGH GY9S080C20UP11 GY9S100C20UP11 M-HI M-LO LOW HIGH GY9S080C16UP11 GY9S100C16UP11 M-HI M-LO LOW HIGH GY9S120D20UP11 GY9S135D20UP11 M-HI M-LO LOW External Static Pressure. Inches W.8 1760 1485 1235 970 1945 1730 1395 1115 0.2 1590 1225 1000 770 1605 1185 915 725 2210 1900 1545 1270 1955 1560 1275 945 2485 2050 1675 1150 0.2 2380 2035 1625 1360 2535 2045 1650 1335 0.4 1480 1185 975 750 1525 1165 940 725 2020 1755 1440 1175 1890 1575 1300 975 2320 1970 1615 1110 0.C 0. Motor voltage at 115 V. 4.3 1535 1205 995 765 1570 1175 935 725 2120 1830 1490 1225 1925 1560 1285 965 2410 1990 1665 1135 0.8 1185 995 825 620 1275 1050 860 660 1595 1390 1155 905 1615 1425 1245 950 1920 1675 1385 980 0.6 1995 1705 1405 1120 2175 1855 1525 1230 0.9 NR NR NR NR 1170 970 815 625 1480 1270 1050 890 1600 1365 1190 910 1785 1545 1285 970 1. 3.C.7 1280 1065 885 655 1350 1100 905 685 1715 1500 1230 990 1695 1475 1280 975 2035 1760 1460 1005 0.6 1340 1110 925 680 1410 1140 920 700 1830 1595 1315 1045 1765 1530 1300 975 2135 1820 1510 1055 0. Airflows above 1800 CFM require either return from two sides or one side plus bottom. Return air is through side opposite motor (left side) for one side return (worst case).7 1875 1605 1315 1070 2075 1785 1470 1180 0.Without Filters (CFM) MODELS Speed Tap HIGH GY9S080C20UP11 GY9S100C20UP11 M-HI M-LO LOW HIGH GY9S120D20UP11 GY9S135D20UP11 M-HI M-LO LOW External Static Pressure. NR = Operation at this static pressure is not recommended.5 2095 1800 1485 1180 2285 1932 1570 1250 0. 0. 5.4 2195 1880 1540 1255 2385 1985 1600 1285 0.9 1620 1360 1125 950 1825 1605 1300 1010 1. 08 0.01 0.c. RECOMMENDED FILTER SIZES Nominal CFM Cabinet Size Side Return Filter in.1250 1251 .750 751 .PRESSURE DROP INCHES W.c.07 2 Opening In w.c. in. Airflow Range Minimum Opening Size 1 Opening Sq.13 0. 3 Rear In. 0 Floor/ Bottom Combustible Closet Alcove Yes Attic Yes Johnson Controls Unitary Products 5 .2000 2001 & Above 230 330 330 330 380 380 463 658 658 658 2 Openings Sq.17 0. 0.c. In w.1500 1501 .17 0.25 0.04 0.15 0.15 0. Actual pressure drop ratings for each filter type vary between filter manufacturer. 0 Right Side In. Filter Type Disposable 1 Opening In w. 0 Left Side In.c.09 2 Opening In w.03 0. WASHABLE FIBER 1 Opening In w.17 0.30 0.1000 1001 .08 0. All velocities over this require the use of high velocity filters.C. 0.15 0.07 0. (cm) 14 x 25 16 x 25 20 x 25 20 x 25 22 x 25 NOTES: 1.30 0. 1 Front In.17 0. UNIT CLEARANCES TO COMBUSTIBLES Application Upflow Top In. 0 Flue In.06 0. Air velocity through throwaway type filters may not exceed 300 feet per minute.14 0. in.08 0.01 0.09 0.17 Pleated 1 Opening 2 Opening In w.30 0. NOTE: The filter pressure drop values in the “Filter Performance” table shown below are typical values for the type of filter listed and should only be used as a guideline. 0 . To determine the approximate blower performance of the system.1750 1751 .20 0. 1200 1200 1600 2000 2000 A B C C D 16 x 25 16 x 25 16 x 25 16 x 25 (2) 16 x 25 Bottom Return Filter in. 0. Air flows above 1800 CFM require either return from two sides or one side plus bottom.07 0.277805-YTG-A-1106 FILTER PERFORMANCE The airflow capacity data published in the “Blower Performance” table listed above represents blower performance WITHOUT filters. FILTER PERFORMANCE .07 0. apply the filter drop value for the filter being used or select an appropriate value from the “Filter Performance” table shown below.20 0.c. 2. XYF80-U. XYF90-U W/031-01975. E*BD.com in the Product Catalog Section. 1 Stage Cooling Ready .L)*8/9S.upgnet.must be set to 0 Thermostat Installer Setup Number 15 Compressor Protection . Johnson Controls Unitary Products .E*RD.(G. HPX13 . ERHS.L)*8/9S. 1 Stage Cooling Ready .Series Demand Control PSC FURNACE CONTROL SINGLE STAGE HEAT PUMP THERMOSTAT *DN22U00124 C 24-Volt Common Y/Y2 Single/Second Stage Cool R 24-Volt Hot C 24-Volt Common Y Single Stage Heat/Cool R 24-Volt Hot N/A N/A W Single Stage Heat G Fan W1/66 First Stage Heat Out W First Stage Heat O Reversing Valve–Energized in Cool X/L Malfunction Light For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.(G. XYF80-U.w/Single Stage Furnace.6 THERMOSTAT *BP11C50124 *BN11C01124 *DP11C40124 *DN11C00124 PSC FURNACE CONTROL SINGLE STAGE AIR CONDITIONING C 24-Volt Common C 24-Volt Common Y/Y2 Single/Second Stage Cool R 24-Volt Hot Y Single Stage Cool C 24-Volt Common Y First Stage Cool RH 24-Volt Hot (Heat XFMR) RC 24-Volt Hot (Cool XFMR) W First Stage Heat G Fan HM1 Humidistat Selection of GAS/ELEC switch on thermostat not necessary AC1 THERMOSTAT *PP11C70224 Single Stage A/C w/Single Stage Furnace. XYF80-U*L. XYF90-U Thermostat Chart Optional w/Batteries Y First Stage Cool RH 24-Volt Hot (Heat XFMR) RC 24-Volt Hot (Cool XFMR) W First Stage Heat G Fan G Fan W Single Stage Heat 24V HUMIDIFIER G Fan THERMOSTAT *BP21H50124 *BN21H00124 *DP21H40124 *DN21H00124 C 24-Volt Common Y First Stage Heat/Cool R 24-Volt Hot W1 Second Stage Heat E Emergency Heat G Fan O Reversing Valve–Energized in Cool L Malfunction Light Step 1 of Thermostat User Configuration Menu must be set to Heat Pump 1 Step 9 of Thermostat User Configuration Menu must be set to Pump OFF 277805-YTG-A-1106 THERMOSTAT *BN11C00124 C 24-Volt Common Y First Stage Cool R 24-Volt Hot (Heat XFMR) RC 24-Volt Hot (Cool XFMR) W First Stage Heat Thermostat Installer Setup Number 1 System Type .must be set to 5 HP1 THERMOSTAT *PP32H70124 Single Stage H/P . XYF80-U*L. Select the filter type. electronic programmable.0. manual change-over electronic non-programmable thermostat. 6. SIDEWALL VENT TERMINATION KIT 1HT0901 (3”) and 1HT0902 (2”) For use on sidewall. Subtract the total system static from 0.040. To determine the system airflow.50) = 0. complete the following steps: 1.For 14-1/2” cabinets 1BR0117 or 1BR0217 . Select the number of return air openings or calculate the return opening size in square inches to determine the proper filter pressure drop.8) x (-110) = -88 5.60" . Johnson Controls Unitary Products 7 .2285 = -110 CFM 3.20.60": 2175 CFM 2.All Models This accessory conversion kit may be used to convert natural gas units for propane (LP) operation. 120 MBH 1PS0322 . 4. 1H/1C. If total system static matches a ESP value in the airflow table (i.50" from the airflow @ 0. (0.e.A wide selection of compatible thermosets are available to provide optimum performance and features for any installation. Multiply percentage by airflow difference to obtain airflow reduction. 2. Provides a more attractive termination for locations where the terminal is visible on the side of the home. 1H/1C. deluxe 7-day.For 17-1/2” cabinets 1BR0121 or 1BR0221 . etc.50" to obtain actual airflow @ 0.e. Subtract the airflow @ 0. sidewall. 1PS0307 . 0.). auto/manual changeover.All Models 1SR0200 . Example: For a 120. auto/manual changeover. to obtain a percentage.50) / (0. CONCENTRIC VENT TERMINATION 1CT0302 (2") 1CT0303 (3") For use through rooftop. 2288 .58.50" and divide this difference by the difference in ESP values in the table. Holds any 16x25x1 permanent or disposable filter.277805-YTG-A-1106 APPLYING FILTER PRESSURE DROP TO DETERMINE SYSTEM AIRFLOW To determine the approximate airflow of the unit with a filter in place. Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static. (0.50". Airflow @ 0. electronic programmable. two-pipe installations only. 2175 .60 . Calcium carbonate refill media is also available from the Source 1 Parts (p/n 026-30228-000). 0.c. 0. Obtain the airflow values at 0. Allows combustion air to enter and exhaust to exit through single common hole. thermostat. refer to the price book or consult factory. 100 MBH 1PS0309 . Determine the External System Static Pressure (ESP) without the filter. the static pressure may be rounded to the nearest value in the table determining the airflow using Step 5 or calculate the airflow by using the following example. CONDENSATE NEUTRALIZER KIT .For 24-1/2” cabinets INTERNAL FILTER WITH FIBER FILTER 1HF0801 .All Models HIGH ALTITUDE PRESSURE SWITCHES For installation where the altitude is less than 8. 0.50": 2285 CFM Airflow @ 0.) the system airflow corresponds to the intersection of the ESP column and Model/ Blower Speed row. Conversions must be made by qualified distributor or dealer personnel.0.All Models BOTTOM RETURN FILTER 1BR0114 or 1BR0214 . 3. follow the steps below: 1. If the total system static falls between ESP values in the table (i. Conversion must be made by qualified distributor or dealer personnel.8 4. * For the most current accessory information. 135 MBH ROOM THERMOSTATS .60.060. it is found that total system static is 0.000 feet see kits below.For 21” cabinets 1BR0124 or 1BR0224 .000 Btuh furnace with 2 return openings and operating on high speed blower.58" ESP.50" & 0. For altitudes above 8.000 feet it is not required that the pressure switch be changed.60" ESP. 5. 1H/1C. SIDE RETURN FILTER 1SR0302 .0.1NK0301 Neutralizer cartridge has a 1/2" plastic tube fittings for installation in the drain line. EXTERNAL SIDE RETURN FILTER RACK 1SF0101 . 0.58 .75.60" to obtain airflow difference.Fits all cabinet sizes Attaches to side of furnace cabinet in side return applications. Subtract airflow reduction value to airflow @ 0.58" w. etc.88 = 2197 ACCESSORIES PROPANE (LP) CONVERSION KIT 1NP0347 .080. S. Copyright © by York International Corp.NOTES Subject to change without notice. All rights reserved. Printed in U. 2006.A. 277805-YTG-A-1106 Supersedes: 246716-YTG-B-0806 Unitary Products Group 5005 York Drive Norman OK 73069 .
Copyright © 2024 DOKUMEN.SITE Inc.