WEG Guia de Selecao de Partidas 50037327 Manual Portugues Br

March 26, 2018 | Author: Jaison Dias Büttenbender | Category: Manufactured Goods, Electromagnetism, Electrical Equipment, Electricity, Electrical Engineering


Comments



Description

Motores | Automação | Energia | Transmissão & Distribuição | TintasAutomação Guia de Seleção de Partidas www.weg.net Índice Direta (Composição: Fusíveis + Contator + Relé de térmico)..................................................................................................... 03 Direta (Composição: Fusíveis + Contator + Relé de sobrecarga inteligente).............................................................................. 05 Direta (Composição: Disjuntor-motor magnético + Contator + Relé de sobrecarga térmico)..................................................... 07 Direta (Composição: Disjuntor-motor magnético + Contator + Relé de sobrecarga inteligente)................................................. 09 Direta (Composição: Disjuntor-motor termomagnético + Contator)............................................................................................11 Direta com reversão (Composição: Fusíveis + Contatores + Relé de sobrecarga térmico).........................................................13 Direta com reversão (Composição: Fusíveis + Contatores + Relé de sobrecarga inteligente).....................................................15 Direta com reversão (Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico)...........................17 Direta com reversão (Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga inteligente).......................19 Direta com reversão (Composição: Disjuntor-motor termomagnético + Contatores)................................................................. 21 Estrela-triângulo (Composição: Fusíveis + Contatores + Relé de sobrecarga térmico).............................................................. 23 Estrela-triângulo (Composição: Fusíveis + Contatores + Relé de sobrecarga inteligente).......................................................... 25 Estrela-triângulo (Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico)................................. 27 Estrela-triângulo (Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga inteligente) . .......................... 29 Estrela-triângulo (Composição: Disjuntor-motor termomagnético + Contatores)........................................................................31 Compensadora (Composição: Fusíveis + Contatores + Relé de sobrecarga térmico)............................................................... 33 Compensadora (Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico).................................. 35 Compensadora (Composição: Disjuntor-motor termomagnético + Contatores)........................................................................ 37 Suave (Composição: Fusíveis ultrarrápidos + Soft-starter)........................................................................................................ 39 2 Guia de Seleção de Partidas www.weg.net Guia de Seleção de Partidas Tipo da partida: Direta Composição: Fusíveis + Contator + Relé de sobrecarga térmico Características g Proteção contra curto-circuito através dos fusíveis tipo gL/gG g Disparador  térmico ajustável para proteção contra sobrecargas através do relé de sobrecarga g Operação automática/remota através do contator Tabela orientativa de motores trifásicos - AC-3 1) Elevada vida útil devido a utilização do contator para manobra g Aplicável a motores que partem a vazio ou a plena carga g Frequência de manobras: 15 manobras/hora 3) g  Fusíveis tipo retardado 4) Referência Faixa de ajuste (A) 2 Contator 2) Referência básica para completar com a tensão de comando CWM9-10-30¨ RW27-1D3-C063 0,4 - 0,63 2 CWM9-10-30¨ RW27-1D3-D008 0,56 - 0,8 FDW-2S 2 CWM9-10-30¨ RW27-1D3-D012 0,8 - 1,2 0,75 / 0,55 FDW-4S 4 CWM9-10-30¨ RW27-1D3-D018 1,2 - 1,8 1 / 0,75 1,5 / 1,1 2 / 1,5 3 / 2,2 4/3 5 / 3,7 6 / 4,5 7,5 / 5,5 10 / 7,5 12,5 / 9,2 15 / 11 20 / 15 25 / 18,5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 FDW-6S FDW-4S FDW-6S FDW-10S FDW-6S FDW-10S FDW-10S FDW-16S FDW-16S FDW-20S FDW-20S FDW-25S FDW-25S FDW-35S FDW-35S FDW-35S FDW-50S FDW-50S FDW-50S FDW-50S FDW-50S FDW-63S FDW-50S FDW-63S FDW-50S FNH000-80U FNH000-80U FNH00-100U FNH00-100U FNH00-100U FNH00-100U FNH00-125U FNH00-160U FNH00-160U FNH00-160U FNH00-160U 6 4 6 10 6 10 10 16 16 20 20 25 25 35 35 35 50 50 50 50 50 63 50 63 50 80 80 100 100 100 100 125 160 160 160 160 CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM12-10-30¨ CWM12-10-30¨ CWM18-10-30¨ CWM18-10-30¨ CWM18-10-30¨ CWM25-10-30¨ CWM25-10-30¨ CWM32-10-30¨ CWM32-10-30¨ CWM32-10-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM80-11-30¨ CWM80-11-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM105-11-30¨ CWM150-22-30¨ RW27-1D3-D018 RW27-1D3-D028 RW27-1D3-D028 RW27-1D3-D028 RW27-1D3-U004 RW27-1D3-U004 RW27-1D3-D063 RW27-1D3-D063 RW27-1D3-U008 RW27-1D3-U008 RW27-1D3-U010 RW27-1D3-U010 RW27-1D3-D125 RW27-1D3-U015 RW27-1D3-U015 RW27-1D3-U017 RW27-1D3-U017 RW27-1D3-U023 RW27-1D3-U032 RW27-1D3-U032 RW67-1D3-U040 RW67-1D3-U040 RW67-1D3-U040 RW67-1D3-U040 RW67-1D3-U050 RW67-2D3-U050 RW67-2D3-U057 RW67-2D3-U057 RW67-2D3-U063 RW67-2D3-U070 RW67-2D3-U080 RW67-2D3-U080 RW67-2D3-U080 RW117-1D3-U097 RW117-1D3-U112 RW317-1D3-U150 1,2 - 1,8 1,8 - 2,8 1,8 - 2,8 1,8 - 2,8 2,8 - 4 2,8 - 4 4 - 6,3 4 - 6,3 5,6 - 8 5,6 - 8 7 - 10 7 - 10 8 - 12,5 10 - 15 10 - 15 11 - 17 11 - 17 15 - 23 22 - 32 22 - 32 25 - 40 25 - 40 25 - 40 25 - 40 32 - 50 32 - 50 40 - 57 40 - 57 50 - 63 57 - 70 63 - 80 63 - 80 63 - 80 75 - 97 90 - 112 100 - 150 220 V cv / kW 380 V cv / kW 440 V cv / kW Referência tamanhos D/NH Corrente nominal (A) - 0,16 / 0,12 0,25 / 0,18 FDW-2S 0,16 / 0,12 0,25 / 0,18 0,16 / 0,12 0,25 / 0,18 0,33 / 0,25 FDW-2S - 0,33 / 0,25 0,5 / 0,37 0,33 / 0,25 0,5 / 0,37 0,75 / 0,55 1 / 0,75 1,5 / 1,1 2 / 1,5 3 / 2,2 4/3 5 / 3,7 6 / 4,5 7,5 / 5,5 10 / 7,5 12,5 / 9,2 15 / 11 20 / 15 25 / 18,5 30 / 22 40 / 30 50 / 37 0,5 / 0,37 0,75 / 0,55 1 / 0,75 1,5 / 1,1 2 / 1,5 3 / 2,2 4/3 5 / 3,7 6 / 4,5 7,5 / 5,5 10 / 7,5 12,5 / 9,2 15 / 11 20 / 15 25 / 18,5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 - - - 60 / 45 75 / 55 100 / 75 125 / 90 - 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 200 350 / 260 400 / 300 450 / 330 500 / 370 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 Relé de sobrecarga FNH1-224U 224 CWM150-22-30¨ RW317-1D3-U150 100 - 150 FNH1-250U FNH1-250U FNH2-300U FNH2-300U FNH2-315U FNH2-355U FNH2-400U FNH2-400U FNH3-425U 250 250 300 300 315 355 400 400 425 CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ CWM300-22-30¨ RW317-1D3-U150 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 100 - 150 140 - 215 140 - 215 140 - 215 200 - 310 200 - 310 200 - 310 200 - 310 200 - 310 300 / 220 FNH3-500U 500 CWM400-22-30¨ RW317-1D3-U420 275 - 420 350 / 260 400 / 300 - FNH3-630U FNH3-630U - 630 630 - CWM630-22-30¨ CWM500-22-30¨ CWM500-22-30¨ CWM630-22-30¨ CWM630-22-30¨ CWM800-22-30¨ RW317-1D3-U420 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U840 RW407-1D3-U840 275 - 420 400 - 600 400 - 600 400 - 600 560 - 840 560 - 840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.800 rpm), regime de serviço contínuo S1, fator de serviço igual a 1 em rede de 60 Hz. Motores em outras condições, analisar os dados de corrente nominal de serviço e corrente de partida; 2) Código das tensões de comando disponível no catálogo específico do produto; 3) Limitada pelas características técnicas do relé de sobrecarga; 4) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras. Consulte catálogo específico do produto. Guia de Seleção de Partidas 3 www.weg.net Guia de Seleção de Partidas Tipo da partida: Direta Composição: Fusíveis + Contator + Relé de sobrecarga térmico Diagramas de Ligação Potência L1 L1 L2 L2 F1 F1 L3 L3 F2 F2 F3 AA A F21 B F22 S0 2 B K1 K1 1 33 55 2 44 6 1 3 5 2 4 6 1 S1 3 4 K1 FT1 FT1 13 K1 14 A2 A1 FT1 95 96 U1 V1 W1 M M 33~ Comando F3 A A F21 F21 B F22 F22 S0 S0 11 22 B S1 S1 33 44 K1 K1 13 13 K1 K1 A2 A2 A1 A1 FT1 FT1 95 95 96 96 W1 4 Guia de Seleção de Partidas 14 14 Descrição F1, F2, F3: Fusíveis de potência K1: Contator FT1: Relé de sobrecarga térmico M: Motor elétrico assincrono trifásico F21, F22: Fusíveis de comando S0, S1: Botões de comando 420 84 .25 .5 .5 0. 3) Código das tensões de comando disponível no catálogo específico do produto.2 4/3 3 / 2.2 FDW-10S 10 CWM9-10-30¨ SRW01-UMC1 0.7 6 / 4.5 .5 .12.5 / 1.25 .840 0.5 .5 12.1 1 / 0.840 - - - CWM800-22-30¨ SRW01-UMC6 84 .37 0.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.75 1.5 .25 0.125 12.5 / 5.5 - 5 / 3. regime de serviço contínuo S1.5 .5 4/3 5 / 3.5 .18 0.25 12.5 FDW-20S 20 CWM9-10-30¨ SRW01-UMC2 1.5 .5 1.2 FDW-50S 50 CWM18-10-30¨ SRW01-UMC3 2. fator de serviço igual a 1 em redes de 60 Hz.25 .5 3 / 2.75 / 0.5 .5 3 / 2. tensão de entradas digitais e tensão de alimentação.5 7.125 40 / 30 50 / 37 FNH00-100U 100 CWM65-11-30¨ SRW01-UMC4 12.5 .5 7.5 / 9.1 7.5 / 0.25 FDW-2S 2 CWM9-10-30¨ SRW01-UMC1 0.55 0.5 10 / 7.840 - - - CWM630-22-30¨ SRW01-UMC6 84 .25 / 0.25 20 / 15 25 / 18.75 / 0.5 .5 . 4) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras.12 0.125 12.12.125 12. Guia de Seleção de Partidas 5 .75 FDW-6S 6 CWM9-10-30¨ SRW01-UMC1 0.840 84 .2 - 4/3 5 / 3.12.33 / 0.37 0.5 / 1.5 / 9.5 / 5.net Guia de Seleção de Partidas Tipo da partida: Direta Composição: Fusíveis + Contator + Relé de sobrecarga inteligente Características g Proteção contra curto-circuito através dos fusíveis tipo gL/gG g Disparador térmico ajustável com classe de disparo de 5 a 45 para proteção contra sobrecargas através do relé inteligente g Operação automática/remota através do contator g Elevada vida útil devido a utilização do contator para manobra g Aplicável a motores que partem a vazio ou a plena carga Tabela orientativa de motores trifásicos .12.5 2 / 1.5 .25 / 0.25 .5 30 / 22 40 / 30 FDW-50S FDW-63S FDW-50S FDW-63S FNH000-80U 50 63 50 63 80 CWM32-10-30¨ CWM32-10-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM50-11-30¨ SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 12.AC-3 Fusíveis tipo retardado 4) 1) Contator 3) Referência básica para completar com a tensão de comando SRW01-UC-˜ 2) + Unidade de medição Unidade de medição Faixa de ajuste (A) Referência 220 V cv / kW 380 V cv / kW 440 V cv / kW Referência tamanhos D/NH Corrente nominal (A) 0.5 10 / 7.420 42 .5 1.2 15 / 11 20 / 15 25 / 18.125 12.800 rpm).420 42 .25 0.1 2 / 1.125 12.420 42 .5 - FDW-16S 16 CWM9-10-30¨ SRW01-UMC2 1.420 350 / 260 400 / 300 - FNH3-630U FNH3-630U - 630 630 - CWM500-22-30¨ CWM500-22-30¨ CWM500-22-30¨ SRW01-UMC5 SRW01-UMC6 SRW01-UMC6 42 . código do tipo de proteção.55 FDW-4S 4 CWM9-10-30¨ SRW01-UMC1 0.420 42 .125 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 200 350 / 260 400 / 300 450 / 330 500 / 370 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 FNH00-100U FNH00-125U FNH00-160U FNH00-160U FNH00-160U FNH00-160U FNH1-224U FNH1-224U FNH1-250U FNH1-250U FNH2-300U FNH2-300U FNH2-315U FNH2-355U FNH2-400U FNH2-400U FNH3-425U 100 125 160 160 160 160 224 224 250 250 300 300 315 355 400 400 425 CWM80-11-30¨ CWM80-11-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM105-11-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ CWM300-22-30¨ SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 12.420 42 .33 / 0.12.2 15 / 11 20 / 15 25 / 18.weg. Consulte catálogo específico do produto.5 / 5. analisar os dados de corrente nominal de serviço e corrente de partida. Consulte catálogo específico do produto.420 42 .5 / 0. 2) Referência básica para substituir “˜” por código do protocolo de comunição.37 0.25 .5 .7 6 / 4.5 / 1.125 12.5 FDW-35S 35 CWM18-10-30¨ SRW01-UMC3 2.75 / 0.www.5 . Motores em outras condições.25 / 0.5 10 / 7.5 / 9.16 / 0.125 12.55 1 / 0.5 1 / 0.5 1.5 .5 1.16 / 0.5 30 / 22 12.33 / 0.18 0.25 15 / 11 FDW-50S 50 CWM25-10-30¨ SRW01-UMC3 2.5 .420 300 / 220 FNH3-500U 500 CWM400-22-30¨ SRW01-UMC5 42 .125 42 .125 12.12 0.5 / 0.5 .125 12.12 0.5 .75 2 / 1.420 42 .16 / 0.5 FDW-25S FDW-25S FDW-35S 25 25 35 CWM9-10-30¨ CWM12-10-30¨ CWM12-10-30¨ SRW01-UMC2 SRW01-UMC2 SRW01-UMC2 1.420 42 .18 0.420 42 .7 6 / 4.125 12.5 . 250 250VCC/240VCA Tensão V CC / 240 V CA 6 Guia de Seleção de Partidas Descrição F1. F3: Fusíveis K1: Contator SRW01-UC: Unidade de controle do relé inteligente SRW01-CB: Cabo de interligação UC+UMC SRW01-UMC: U  nidade de medição de corrente do relé inteligente M: Motor elétrico assincrono trifásico F21. 250VCC/240VCA U1 U1 3 3 W1 W1 V1 V1 M M Comando 110-240 V CA / V CC 110-240 VCA/VCC ou 2424 V CA / V CC VCA/VCC 11 3 3 2 2 44 S1 S1 I1 I1 K1 K1 I2 I2 I1 13 13 F22 F22 S0 14 14 I3 I4 IC A2 A1 A1 SRW01-UC SRW01-UC SRW01-CB SRW01-CB C1 C1 W01-CB K1 K1 O1 O1 O2 O2 C3 C3 O3 O3 C4 C4 O4 O4 A1 A1 A2 A2 F21 F21 Tensão máx. F22: Fusíveis de comando S0.www. F2. S1: Botões de comando .net Guia de Seleção de Partidas Tipo da partida: Direta Composição: Fusível + Contator + Relé de sobrecarga inteligente Diagramas de Ligação Potência L2 L2 110-240 VCA/VCC ou 24 VCA/VCC L3 L3 1 S0 F1 F1 F2 F2 3 S1 2 F3 F3 14 I2 I3 I4 IC A2 A1 SRW01-UC 1 3 5 2 4 6 L1 L1 L2 L2 L3 L3 SRW01-CB C1 SRW01-CB SRW01-CB SRW01-UMC SRW01-UMC 13 4 I1 K1 K1 K1 F22 L1 O1 C3 O2 O3 C4 O4 A1 K1 A2 F21 T1 T3 T2 Tensão máx. máx.weg. 5 7.1.7 6 / 4.23 22 .6.5 12.75 / 0.5 8 .12 0.75 / 0.7 6 / 4. Motores em outras condições.7 6 / 4.33 / 0.2 4/3 5 / 3.215 140 .5 1.17 11 .2 .5 / 1.1.5 10 / 7.63 0. regime de serviço contínuo S1.2 0.1.8 7 .5 4 CWM9-10-30¨ CWM9-10-30¨ RW27-1D3-D028 RW27-1D3-D028 1.15 11 .57 40 .32 22 .12 0.600 DWM1600H-700-3 DWM1600H-700-3 700 700 CWM630-22-30¨ CWM800-22-30¨ RW407-1D3-U840 RW407-1D3-U840 560 .18 0.37 0. Guia de Seleção de Partidas 7 .33 / 0.420 400 .112 DWB250N150-3MF 150 CWM150-22-30¨ RW317-1D3-U150 100 .12. analisar os dados de corrente nominal de serviço e corrente de partida.12 0.2 4/3 5 / 3.600 400 .4 3 / 2.25 0.5 / 5.5 10 .8 .33 / 0.5 / 9.2.50 40 .6 .5 3 / 2.16 / 0.2 2 / 1.5 12.840 560 .310 300 / 220 DWM800H-420-3 420 CWM400-22-30¨ RW317-1D3-U420 275 . 2) Código das tensões de comando disponível no catálogo específico do produto.3 CWM9-10-30¨ RW27-1D3-D063 4 .5 / 9.5 7.8 .2 .2 4/3 5 / 3.2 RW27-1D3-D018 1.5 / 5.25 - 0.63 0.80 75 .5 15 / 11 20 / 15 25 / 18.75 / 0.AC-3 1) 220 V cv / kW 380 V cv / kW 440 V cv / kW 0.25 / 0.5 / 0. 3) Limitada pelas características técnicas do disjuntor-motor e do relé de sobrecarga.37 0.25 0.1 2 / 1.55 1 / 0.25 / 0.2 15 / 11 20 / 15 25 / 18.40 MPW65i-3-U040 MPW65i-3-U050 MPW65i-3-U050 MPW65i-3-U065 MPW65i-3-U065 MPW65i-3-U065 DWB160N80-3MF DWB160N95-3MF DWB250N105-3MF 40 50 50 65 65 65 80 95 105 CWM40-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM105-11-30¨ RW67-1D3-U050 RW67-2D3-U050 RW67-2D3-U057 RW67-2D3-U057 RW67-2D3-U063 RW67-2D3-U070 RW67-2D3-U080 RW117-1D3-U097 RW117-1D3-U112 32 .16 / 0.5 / 1.18 0.net Guia de Seleção de Partidas Tipo da partida: Direta Composição: Disjuntor-motor magnético + Contator + Relé de sobrecarga térmico Características g Proteção  contra curto-circuito e seccionamento com possibilidade de bloqueio mecânico para evitar religamento do circuito g Disparador  magnético fixo e calibrado em 12 e 13 vezes a corrente máxima do disjuntor g Disparador  térmico ajustável para proteção contra sobrecargas através do relé de sobrecarga g Operação automática/remota através do contator g Elevada  vida útil devido a utilização do contator para manobra g Aplicável  a motores que partem a vazio ou a plena carga g Frequência de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .97 90 .weg.150 DWB250N185-3MF DWM400H-250-3 185 250 CWM180-22-30¨ CWM250-22-30¨ RW317-1D3-U215 RW317-1D3-U215 140 .310 DWM400H-320-3 320 CWM300-22-30¨ RW317-1D3-U310 200 . fator de serviço igual a 1 em redes de 60 Hz.5 CWM9-10-30¨ RW27-1D3-D018 1.8 1.50 32 .1 3 / 2.5 / 9.6 CWM9-10-30¨ Relé de sobrecarga Referência Faixa de ajuste (A) RW27-1D3-C063 RW27-1D3-D008 RW27-1D3-D012 RW27-1D3-D012 0.57 50 .8 5.8 - MPW25i-3-D025 2.8 2 / 1.8 0.2.75 1.2 15 / 11 20 / 15 - 25 / 18.0.75 0.3 10 10 10 16 16 16 16 20 20 25 32 32 CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM12-10-30¨ CWM12-10-30¨ CWM12-10-30¨ CWM18-10-30¨ CWM18-10-30¨ CWM18-10-30¨ CWM25-10-30¨ CWM25-10-30¨ CWM32-10-30¨ CWM32-10-30¨ RW27-1D3-U008 RW27-1D3-U008 RW27-1D3-U010 RW27-1D3-D125 RW27-1D3-D125 RW27-1D3-U015 RW27-1D3-U015 RW27-1D3-U017 RW27-1D3-U017 RW27-1D3-U017 RW27-1D3-U032 RW27-1D3-U032 RW67-1D3-U040 5.10 8 .4 .5 12.55 1 / 0.18 0.6 Contator 2) Referência básica para completar com a tensão de comando CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ CWM9-10-30¨ MPW25i-3-D016 1.17 15 .6 .40 MPW65i-3-U040 40 CWM40-11-30¨ RW67-1D3-U040 25 .0.8 .32 25 .70 63 .75 0.600 DWM1600H-700-3 700 CWM630-22-30¨ RW407-1D3-U600 400 .12.www.8 .8 1.15 10 .55 1 / 0.16 / 0.5 10 / 7.1.215 DWM400H-250-3 250 CWM250-22-30¨ RW317-1D3-U310 200 .5 MPW25i-3-U004 4 CWM9-10-30¨ RW27-1D3-U004 2.3 MPW25i-3-D063 MPW25i-3-U010 MPW25i-3-U010 MPW25i-3-U010 MPW25i-3-U016 MPW25i-3-U016 MPW25i-3-U016 MPW25i-3-U016 MPW25i-3-U020 MPW25i-3-U020 MPW25i-3-U025 MPW25i-3-U032 MPW25i-3-U032 6.63 57 .56 .37 0.800 rpm).1 - MPW25i-3-D025 MPW25i-3-U004 2.5 10 / 7.5 / 0.5 / 1.840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.5 / 0.25 / 0.63 1 1.5 7.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 - 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 100 / 75 175 / 132 125 / 90 200 / 150 250 / 185 300 / 220 350 / 260 150 / 110 175 / 132 200 / 150 - 400 / 300 250 / 185 300 / 220 450 / 330 500 / 370 Disjuntor-motor magnético Referência Corrente nominal (A) MPW25i-3-C063 MPW25i-3-C063 MPW25i-3-U001 MPW25i-3-D016 0.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 MPW25i-3-D063 6.8 .420 350 / 260 400 / 300 450 / 330 500 / 370 - DWM800H-420-3 DWM800H-420-3 DWM800H-500-3 420 420 500 CWM500-22-30¨ CWM500-22-30¨ CWM500-22-30¨ RW317-1D3-U420 RW407-1D3-U600 RW407-1D3-U600 275 .5 / 5. weg. S1: Botões de comando .www.net Guia de Seleção de Partidas Tipo da partida: Direta Composição: Disjuntor-motor magnético + Contator + Relé de sobrecarga térmico Diagramas de Ligação Potência L1 L1 11 L2 L2 L3 L3 33 55 A F21 B F22 S0 Q1 Q1 1 2 II> > II> > 22 4 I> I> 6 AA S1 B 1 3 5 22 4 6 3 13 K1 4 14 K1 K1 K1 A2 A1 11 33 5 22 44 6 U1 V1 W1 W1 FT1 FT1 FT1 95 96 M M 33~ Comando A F21 F21 B F22 F22 S0 S0 11 22 A S1 S1 B 13 33 K1 K1 44 K1 A2 A1 FT1 FT1 95 95 96 96 8 Guia de Seleção de Partidas 14 14 Descrição Q1: Disjuntor-motor magnético K1: Contator FT1: Relé de sobrecarga térmico M: Motor elétrico assincrono trifásico F21. F22: Fusíveis de comando S0. www.5 / 0.420 DWM400H-320-3 320 CWM300-22-30¨ SRW01-UMC5 42 .12.5 10 / 7.5 0.5 2 / 1.5 .5 / 5.2 4/3 5 / 3.5 / 9.37 0.5 10 / 7.5 MPW25i-3-D063 6.5 3 / 2.420 DWB250N185-3MF 185 CWM180-22-30¨ SRW01-UMC5 42 .420 DWM400H-250-3 250 CWM250-22-30¨ SRW01-UMC5 42 .12.12 0.18 MPW25i-3-C063 0.12.2 15 / 11 15 / 11 25 / 18.5 .5 .5 .25 MPW25i-3-U001 1 CWM9-10-30¨ SRW01-UMC1 0. 2) Referência básica para substituir “˜” por código do protocolo de comunição.25 / 0.55 1 / 0.5 / 9.5 .5 6 / 4.5 MPW25i-3-U010 10 CWM9-10-30¨ SRW01-UMC2 1.5 1. Motores em outras condições.7 6 / 4. regime de serviço contínuo S1.2 5 / 3.5 .25 0.5 / 0.125 DWB250N150-3MF 150 CWM150-22-30¨ SRW01-UMC5 42 .5 / 1.840 DWM1600H-700-3 700 CWM630-22-30¨ SRW01-UMC6 84 .7 6 / 4.5 7.2 12.55 1 / 0.125 25 / 18.5 3 / 2.25 / 0. Guia de Seleção de Partidas 9 . tensão de entradas digitais e tensão de alimentação.25 2. 3) Código das tensões de comando disponíveis no catálogo específico do produto.2 4/3 4/3 5 / 3.5 .7 10 / 7.33 / 0.5 / 1. 4) Limitada pelas características técnicas do disjuntor-motor.12 0.net Guia de Seleção de Partidas Tipo da partida: Direta trifásica Composição: Disjuntor-motor magnético + Contator + Relé de sobrecarga inteligente Características g Proteção  contra curto-circuito através do disjuntor-motor magnético g Disparador  térmico ajustável com classe de disparo de 5 a 45 para proteção contra sobrecargas através do relé inteligente g Operação  automática/remota através do contator g Elevada  vida útil devido a utilização do contator para manobra g Aplicável  a motores que partem a vazio ou a plena carga g Frequência  de manobras: 15 manobras/hora 4) Tabela orientativa de motores trifásicos .75 / 0.16 / 0.63 CWM9-10-30¨ SRW01-UMC1 0. Consulte catálogo específico do produto.5 .25 .5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 30 / 22 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 20 / 15 Disjuntor-motor magnético Contator Referência básica para completar com a tensão de comando SRW01-UC-˜ 2) + Unidade de medição Unidade de medição Faixa de ajuste (A) Referência Referência Corrente nominal (A) 0.5 MPW25i-3-U004 4 CWM9-10-30¨ SRW01-UMC1 0.5 .420 350 / 260 400 / 300 450 / 330 500 / 370 - DWM800H-420-3 DWM800H-500-3 420 500 CWM500-22-30¨ CWM500-22-30¨ SRW01-UMC5 SRW01-UMC6 42 .125 40 / 30 50 / 37 MPW65i-3-U065 65 CWM65-11-30¨ SRW01-UMC4 12. fator de serviço igual a 1 em redes de 60 Hz.5 .16 / 0.25 2.5 / 5.18 0.125 50 / 37 60 / 45 75 / 55 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 DWB160N80-3MF DWB160N95-3MF DWB250N105-3MF 80 95 105 CWM80-11-30¨ CWM95-11-30¨ CWM105-11-30¨ SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 12.25 0.5 CWM9-10-30¨ SRW01-UMC1 0.800 rpm).1 2 / 1.75 1.5 0.6 CWM9-10-30¨ SRW01-UMC1 0.5 3 / 2.5 .75 / 0.1 MPW25i-3-D025 2.5 .16 / 0.2 15 / 11 - MPW25i-3-U016 16 CWM18-10-30¨ SRW01-UMC3 2.5 12.840 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 350 / 260 400 / 300 450 / 330 500 / 370 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.5 .5 20 / 15 25 / 18.5 . analisar os dados de corrente nominal de serviço e corrente de partida.5 .75 1.5 7.125 12.75 MPW25i-3-D016 1.840 DWM1600H-700-3 700 CWM800-22-30¨ SRW01-UMC6 84 .5 0.33 / 0.37 0.5 1.125 MPW65i-3-U050 50 CWM50-11-30¨ SRW01-UMC4 12.25 .3 CWM9-10-30¨ SRW01-UMC2 1.25 .5 MPW25i-3-U010 MPW25i-3-U016 10 16 CWM12-10-30¨ CWM12-10-30¨ SRW01-UMC2 SRW01-UMC2 1.5 / 5.5 / 1.5 30 / 22 40 / 30 MPW65i-3-U040 40 CWM40-11-30¨ SRW01-UMC4 12.5 12.125 12.37 0.25 MPW25i-3-U020 MPW25i-3-U020 MPW25i-3-U025 20 20 25 CWM18-10-30¨ CWM25-10-30¨ CWM25-10-30¨ SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 2.18 0.420 84 .AC-3 1) 220 V cv / kW 380 V cv / kW 440 V cv / kW - 0.5 .25 .25 20 / 15 MPW25i-3-U032 32 CWM32-10-30¨ SRW01-UMC4 12.33 / 0.75 / 0.12 0.1 2 / 1.25 / 0.55 1 / 0.420 300 / 220 DWM800H-420-3 420 CWM400-22-30¨ SRW01-UMC5 42 .12.5 / 0.5 / 9. código do tipo de proteção.5 7.weg. 240 V VCA/VCC CA / V CC ou 24V CA VCA/VCC 24 / V CC 11 S1 S1 3 22 4 I1 I1 I2 I2 K1 K1 13 13 F22 F22 S0 14 14 I3 I3 I4 I4 IC IC A2 A1 A1 SRW01-UC SRW01 .UMC O1 O2 C3 O3 C4 O4 A1 K1 A2 F21 T1 T2 T3 Tensão máx.UC SRW01 .www.weg. 250VCC/240VCA U1 U1 33 V1 V1 W1 W1 M Comando 110-240 110 . S1: Botões de comando .CB SRW01-CB C1 C1 RW01-CB K1 K1 O1 O1 O2 C3 C3 O3 O3 C4 C4 O4 O4 A1 A2 A2 F21 F21 Tensão máx. F22: Fusíveis de comando S0.net Guia de Seleção de Partidas Tipo da partida: Direta trifásica Composição: Disjuntor-motor magnético + Contator + Relé de sobrecarga inteligente Diagramas de Ligação Potência L2 L2 L3 L3 1 1 3 3 5 5 110-240 VCA/VCC ou 24 VCA/VCC 1 S0 Q1 Q1 3 S1 2 > II> 2 > II> 4 > II> 6 1 3 5 K1 13 4 14 I2 I3 I1 F22 L1 L1 I4 IC A2 A1 SRW01-UC SRW01-CB K1 K1 2 4 6 6 L1 L1 L2 L2 L3 C1 SRW01 .250 250VCC/240VCA Tensão V CC / 240 V CA 10 Guia de Seleção de Partidas Descrição Q1: Disjuntor-motor magnético K1: Contator SRW01-UC: Unidade de controle do relé inteligente SRW01-CB: Cabo de interligação UC+UMC SRW01-UMC: U  nidade de medição de corrente do relé inteligente M: Motor elétrico assincrono trifásico F21. máx.CB SRW01-CB SRW01-UMC SRW 01 . 16 / 0.0. 3) Limitada pelas características técnicas do disjuntor-motor.25 / 0.12 0. fator de serviço igual a 1 em redes de 60 Hz. regime de serviço contínuo S1.5 30 / 22 40 / 30 25 / 18.3 .5 / 9.25 MPW25-3-U001 0.32 CWM32-10-30¨ MPW65-3-U040 32 .2 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.5 0.1.5 CWM9-10-30¨ 2 / 1.5 / 0.7 6 / 4.18 MPW25-3-C063 0.5 / 5.5 / 1.40 40 .20 16 .33 / 0.6 CWM9-10-30¨ 1.5 7.1 2 / 1.20 20 .5 / 1.25 CWM18-10-30¨ CWM25-10-30¨ CWM25-10-30¨ MPW25-3-U032 25 . Motores em outras condições.4 .37 0.5 / 0.5 5 / 3.5 / 5.75 1.800 rpm).100 CWM80-11-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM105-11-30¨ 3 / 2.1 CWM9-10-30¨ 0.5 7.1 MPW25-3-D025 1.37 0.75 MPW25-3-D016 1 .5 MPW25-3-U004 2.50 CWM50-11-30¨ CWM50-11-30¨ 0.10 CWM9-10-30¨ MPW25-3-U010 MPW25-3-U016 6.4 CWM9-10-30¨ MPW25-3-D063 4 .75 70 .25 0.weg.1 2 / 1.5 10 / 7.AC-3 Disjuntor-motor termomagnético 1) Contator 2) Referência básica para completar com a tensão de comando 220 V cv / kW 380 V cv / kW 440 V cv / kW Referência Faixa de ajuste (A) - 0.2 4/3 5 / 3.16 CWM12-10-30¨ CWM12-10-30¨ MPW25-3-U016 10 .16 / 0.net Guia de Seleção de Partidas Tipo da partida: Direta Composição: Disjuntor-motor termomagnético + Contator Características g Proteção  contra curto-circuito e seccionamento com possibilidade de bloqueio mecânico para evitar religamento do circuito g Disparador  magnético fixo e calibrado em 13 vezes a corrente máxima do disjuntor g Disparador  térmico ajustável para proteção contra sobrecargas incorporado no disjuntor g Operação  automática/remota através do contator g Elevada  vida útil devido a utilização do contator para manobra g Aplicável  a motores que partem a vazio ou a plena carga g Frequência  de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .5 7.2 15 / 11 - 20 / 15 20 / 15 - - 15 / 11 20 / 15 25 / 18.75 / 0.12 0.55 1 / 0.2 3 / 2.7 10 / 7.5 6 / 4.65 CWM65-11-30¨ 50 / 37 60 / 45 - 60 / 45 75 / 55 - MPW100-3-U075 MPW100-3-U090 MPW100-3-U090 MPW100-3-U100 55 .2.5 / 9.16 CWM18-10-30¨ MPW25-3-U020 MPW25-3-U020 MPW25-3-U025 16 .5 30 / 22 40 / 30 40 / 30 50 / 37 MPW65-3-U065 50 . analisar os dados de corrente nominal de serviço e corrente de partida.16 / 0.25 / 0.www. Guia de Seleção de Partidas 11 .55 1 / 0.18 0.63 CWM9-10-30¨ 0.33 / 0.75 / 0.5 / 1.3 CWM9-10-30¨ MPW25-3-U010 6.75 / 0.90 70 .5 12.6.2 15 / 11 3 / 2.5 .5 / 9.3 .25 0.5 4/3 4/3 5 / 3.63 .25 / 0.33 / 0.40 CWM40-11-30¨ MPW65-3-U040 MPW65-3-U050 32 .5 / 0.5 10 / 7.5 30 / 22 25 / 18.5 / 5.6 .55 1 / 0.90 80 .12 0.18 0.37 0.10 10 .2 12.5 12. 2) Código das tensões de comando disponível no catálogo específico do produto.7 6 / 4.75 1. www.weg.net Guia de Seleção de Partidas Tipo da partida: Direta Composição: Disjuntor-motor termomagnético + Contator Diagramas de Ligação Potência L1 L1 11 L2 L3 L3 33 55 A F21 B F22 S0 Q1 Q1 1 2 > II> 22 I> I> I> I> 44 6 AA S1 BB 1 33 55 22 44 66 K1 3 13 K1 4 K1 A2 A1 U1 V1 W1 M 3~ 3 Comando AA F21 B F22 F22 S0 11 22 S1 S1 K1 13 13 33 44 K1 14 14 A2 A1 12 Guia de Seleção de Partidas Descrição Q1: Disjuntor-motor termomagnético K1: Contator M: Motor elétrico assincrono trifásico F21. S1: Botões de comando 14 . F22: Fusíveis de comando S0. regime de serviço contínuo S1.5 7.8 1.97 90 .12 0.25 - 0.420 350 / 260 400 / 300 - FNH3-630U FNH3-630U - 630 630 - 2 x CWM630-22-30¨ 2 x CWM500-22-30¨ 2 x CWM500-22-30¨ 2 x CWM630-22-30¨ 2 x CWM630-22-30¨ 2 x CWM800-22-30¨ RW317-1D3-U420 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U840 RW407-1D3-U840 275 .5 12.5 / 9.0.7 6 / 4.150 FNH1-250U FNH1-250U FNH2-300U FNH2-300U FNH2-315U FNH2-355U FNH2-400U FNH2-400U FNH3-425U 250 250 300 300 315 355 400 400 425 2 x CWM150-22-30¨ 2 x CWM180-22-30¨ 2 x CWM180-22-30¨ 2 x CWM250-22-30¨ 2 x CWM250-22-30¨ 2 x CWM250-22-30¨ 2 x CWM250-22-30¨ 2 x CWM300-22-30¨ 2 x CWM300-22-30¨ RW317-1D3-U150 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 100 .5 / 1.840 560 .75 / 0.8 .310 200 .17 11 .63 57 .5 3 / 2. fator de serviço igual a 1 em rede de 60 Hz.12 - 0.25 / 0.18 0.23 22 .80 75 .8 5.1.18 0.70 63 .17 15 .15 10 .32 25 .0.5 / 0.5 3 / 2.4 .weg.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Fusíveis + Contatores + Relé de sobrecarga térmico Características g Proteção  contra curto-circuito através dos fusíveis tipo gL/gG g Disparador  térmico ajustável para proteção contra sobrecargas através do relé de sobrecarga g Operação  automática/remota através do contator g Elevada  vida útil devido a utilização do contator para manobra g Aplicável  a motores que partem a vazio ou a plena carga g Frequência de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .2.37 0.32 22 . 4) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras.5 / 1.3 5.5 7.5 / 5.5 / 0.310 200 . 3) Limitada pelas características técnicas do relé de sobrecarga.40 25 . 2) Código das tensões de comando disponíveis no catálogo específico do produto.6 .18 0.75 / 0.55 1 / 0.5 / 1.600 400 .310 200 .37 0.5 7.5 / 9.2 0.1 2 / 1.80 63 .2 4/3 5 / 3.5 3 / 2.33 / 0.3 4 .40 25 .8 1 / 0.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 - - - 60 / 45 75 / 55 100 / 75 125 / 90 - 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 200 350 / 260 400 / 300 450 / 330 500 / 370 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 Fusíveis tipo retardado 4) FDW-2S 2 Contator 2) Referência básica para completar com a tensão de comando 2 x CWM9-10-30¨ RW27-1D3-C063 0.215 140 .37 FDW-2S 2 2 x CWM9-10-30¨ RW27-1D3-D012 0.6 .5 10 / 7.75 / 0.63 FDW-2S 2 2 x CWM9-10-30¨ RW27-1D3-D008 0.5 10 .5 / 5.2.8 1.8 .5 12.16 / 0.310 300 / 220 FNH3-500U 500 2 x CWM400-22-30¨ RW317-1D3-U420 275 .16 / 0.310 200 .2 .840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.www.2 15 / 11 20 / 15 25 / 18.55 1 / 0.112 100 . analisar os dados de corrente nominal de serviço e corrente de partida.40 32 .12.57 50 .2.2 15 / 11 20 / 15 25 / 18. Motores em outras condições.800 rpm).75 1.55 FDW-4S 4 2 x CWM9-10-30¨ RW27-1D3-D018 1.25 / 0.75 1. Guia de Seleção de Partidas 13 .8 1.5 12.16 / 0.5 10 / 7.56 .600 560 .57 40 .5 30 / 22 40 / 30 50 / 37 0.2 4/3 5 / 3.5 10 / 7.2 4/3 5 / 3.5 / 9.50 40 .215 140 .8 .150 140 .25 0.33 / 0. Consulte catálogo específico do produto.8 .7 6 / 4.1 2 / 1.25 / 0.600 400 .AC-3 1) 220 V cv / kW 380 V cv / kW 440 V cv / kW 0.6.33 / 0.8 .5 / 0.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 FDW-6S FDW-4S FDW-6S FDW-10S FDW-6S FDW-10S FDW-10S FDW-16S FDW-16S FDW-20S FDW-20S FDW-25S FDW-25S FDW-35S FDW-35S FDW-35S FDW-50S FDW-50S FDW-50S FDW-50S FDW-50S FDW-63S FDW-50S FDW-63S FDW-50S FNH000-80U FNH000-80U FNH00-100U FNH00-100U FNH00-100U FNH00-100U FNH00-125U FNH00-160U FNH00-160U FNH00-160U FNH00-160U 6 4 6 10 6 10 10 16 16 20 20 25 25 35 35 35 50 50 50 50 50 63 50 63 50 80 80 100 100 100 100 125 160 160 160 160 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM12-10-30¨ 2 x CWM12-10-30¨ 2 x CWM18-10-30¨ 2 x CWM18-10-30¨ 2 x CWM18-10-30¨ 2 x CWM25-10-30¨ 2 x CWM25-10-30¨ 2 x CWM32-10-30¨ 2 x CWM32-10-30¨ 2 x CWM32-10-30¨ 2 x CWM40-11-30¨ 2 x CWM40-11-30¨ 2 x CWM40-11-30¨ 2 x CWM50-11-30¨ 2 x CWM50-11-30¨ 2 x CWM65-11-30¨ 2 x CWM65-11-30¨ 2 x CWM65-11-30¨ 2 x CWM80-11-30¨ 2 x CWM80-11-30¨ 2 x CWM80-11-30¨ 2 x CWM95-11-30¨ 2 x CWM105-11-30¨ 2 x CWM150-22-30¨ RW27-1D3-D018 RW27-1D3-D028 RW27-1D3-D028 RW27-1D3-D028 RW27-1D3-U004 RW27-1D3-U004 RW27-1D3-D063 RW27-1D3-D063 RW27-1D3-U008 RW27-1D3-U008 RW27-1D3-U010 RW27-1D3-U010 RW27-1D3-D125 RW27-1D3-U015 RW27-1D3-U015 RW27-1D3-U017 RW27-1D3-U017 RW27-1D3-U023 RW27-1D3-U032 RW27-1D3-U032 RW67-1D3-U040 RW67-1D3-U040 RW67-1D3-U040 RW67-1D3-U040 RW67-1D3-U050 RW67-2D3-U050 RW67-2D3-U057 RW67-2D3-U057 RW67-2D3-U063 RW67-2D3-U070 RW67-2D3-U080 RW67-2D3-U080 RW67-2D3-U080 RW117-1D3-U097 RW117-1D3-U112 RW317-1D3-U150 1.15 11 .10 8 .2 .150 FNH1-224U 224 2 x CWM150-22-30¨ RW317-1D3-U150 100 .1.8 7 .1 2 / 1.7 6 / 4.2 15 / 11 20 / 15 25 / 18.8 Referência tamanhos D/NH Corrente nominal (A) Relé de sobrecarga Referência Faixa de ajuste (A) 0.8 .12 0.4 2.420 400 .215 200 .6.75 1.8 2.10 7 .50 32 .25 0.40 25 .80 63 .4 4 .5 / 5.1. F3: Fusíveis de potência K1. S1. F22: Fusíveis de comando S0.02: Intertravamento elétrico e mecânico F21.02 BLIM.weg. K2: Contatores FT1: Relé de sobrecarga térmico M: Motor elétrico assincrono trifásico BLIM.www.02 K2 4 14 22 13 3 A2 M M 33~ Comando AA F21 F21 BB F22 F22 S0 S0 S1 S1 K2 K2 K1 K1 14 11 22 33 13 13 K1 K1 44 14 14 21 21 BLIM.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Fusíveis + Contatores + Relé de sobrecarga térmico Diagramas de Ligação Potência L1 L1 L2 L2 F1 L3 L3 F2 F3 A F21 B F22 AA S0 2 BB K1 K1 11 33 55 422 44 66 K2 K2 11 33 55 422 44 66 1 S1 3 4 21 11 33 55 22 44 66 K2 FT1 FT1 13 K1 S2 BLIM.02 A2 A2 Guia de Seleção de Partidas A1 A1 K2 K2 A2 A2 FT1 FT1 95 95 96 96 Descrição F1.02 A1 32 V1 V1 K2 A2 W1 W1 FT1 A1 K1 U1 U1 14 31 K1 BLIM.02 33 44 K2 K2 13 13 14 14 31 31 K1 K1 32 32 22 22 A1 A1 S2 S2 BLIM. F2. S2: Botões de comando 95 96 .02 BLIM. 5 / 1.12. fator de serviço igual a 1 em redes de 60 Hz.125 12.2 15 / 11 20 / 15 25 / 18.37 0.12.5 40 / 30 FDW-50S FDW-50S FDW-50S FDW-50S FDW-63S FDW-63S FDW-50S FNH000-80U 50 50 50 50 63 63 50 80 2 x CWM18-10-30¨ 2 x CWM25-10-30¨ 2 x CWM25-10-30¨ 2 x CWM32-10-30¨ 2 x CWM32-10-30¨ 2 x CWM40-11-30¨ 2 x CWM40-11-30¨ 2 x CWM50-11-30¨ SRW01-UMC3 SRW01-UMC3 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 2.5 30 / 22 40 / 30 50 / 37 5 / 3.5 / 0.55 FDW-4S 4 2 x CWM9-10-30¨ SRW01-UMC1 0.5 FDW-25S FDW-25S FDW-35S 25 25 35 2 x CWM9-10-30¨ 2 x CWM12-10-30¨ 2 x CWM12-10-30¨ SRW01-UMC2 SRW01-UMC2 SRW01-UMC3 1.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Fusíveis + Contatores + Relé de sobrecarga inteligente Características g Proteção  contra curto-circuito através dos fusíveis tipo gL/gG g Disparador  térmico ajustável com classe de disparo de 5 a 45 para proteção contra sobrecargas através do relé de sobrecarga inteligente g Operação  automática/remota através do contator g Elevada  vida útil devido a utilização do contator para manobra g Aplicável  a motores que partem a vazio ou a plena carga Tabela orientativa de motores trifásicos .5 / 9. analisar os dados de corrente nominal de serviço e corrente de partida.1 2 / 1.5 / 0.75 / 0.420 300 / 220 FNH3-500U 500 2 x CWM400-22-30¨ SRW01-UMC5 42 .840 84 .5 / 1.2 15 / 11 20 / 15 30 / 22 25 / 18.5 .25 .5 3 / 2.12 0.33 / 0.7 6 / 4.5 .www.75 1.5 30 / 22 12.5 .2 15 / 11 20 / 15 25 / 18.125 12.12 0.840 84 .420 42 .75 / 0.5 10 / 7.12.5 0.25 0.5 / 5. Consulte catálogo específico do produto.5 0. 3) Código das tensões de comando disponíveis no catálogo específico do produto.18 0.5 FDW-20S 20 2 x CWM9-10-30¨ SRW01-UMC2 1.5 .800 rpm).16 / 0.55 0.5 .125 12.75 1 / 0.7 6 / 4.5 10 / 7. 2) Referência básica para substituir “˜” por código do protocolo de comunição.125 42 .2 - 4/3 5 / 3.12 0.840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.420 42 . Guia de Seleção de Partidas 15 .5 12.5 .25 .840 84 .2 4/3 5 / 3.5 / 0.125 12.5 .5 - FDW-10S FDW-16S 10 16 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ SRW01-UMC2 SRW01-UMC2 1.125 40 / 30 50 / 37 FNH00-100U 100 2 x CWM65-11-30¨ SRW01-UMC4 12. Motores em outras condições.25 . 4) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras.420 42 .125 50 / 37 60 / 45 75 / 55 - 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 FNH00-100U FNH00-125U FNH00-160U FNH00-160U FNH00-160U FNH00-160U 100 125 160 160 160 160 2 x CWM80-11-30¨ 2 x CWM80-11-30¨ 2 x CWM80-11-30¨ 2 x CWM95-11-30¨ 2 x CWM105-11-30¨ 2 x CWM150-22-30¨ SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC5 12.5 7.16 / 0.7 6 / 4.5 .25 0.420 42 .5 .420 84 .5 FDW-35S 35 2 x CWM18-10-30¨ SRW01-UMC3 2.840 84 .5 7.420 42 .12.25 12. tensão de entradas digitais e tensão de alimentação.2 4/3 2 / 1.420 FNH1-250U FNH1-250U FNH2-300U FNH2-300U FNH2-315U FNH2-355U FNH2-400U FNH2-400U FNH3-425U 250 250 300 300 315 355 400 400 425 2 x CWM150-22-30¨ 2 x CWM180-22-30¨ 2 x CWM180-22-30¨ 2 x CWM250-22-30¨ 2 x CWM250-22-30¨ 2 x CWM250-22-30¨ 2 x CWM250-22-30¨ 2 x CWM300-22-30¨ 2 x CWM300-22-30¨ SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 42 .125 12.125 12.AC-3 1) Fusíveis tipo retardado 4) Contator 2) Referência básica para completar com a tensão de comando SRW01-UC-˜ 2) + Unidade de medição Unidade de medição Faixa de ajuste (A) Referência 220 V cv / kW 380 V cv / kW 440 V cv / kW Referência tamanhos D/NH Corrente nominal (A) 0.25 .5 / 5.5 .5 .5 1 / 0.125 12.420 42 .5 / 9.25 / 0.18 0.37 0.5 7.37 0.420 42 .5 - - 60 / 45 75 / 55 100 / 75 125 / 90 - 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 200 350 / 260 400 / 300 450 / 330 500 / 370 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 FNH1-224U 224 2 x CWM150-22-30¨ SRW01-UMC5 42 .5 .25 .420 3 / 2.25 / 0.75 1.25 FDW-2S 2 2 x CWM9-10-30¨ SRW01-UMC1 0. código do tipo de proteção. Consulte catálogo específico do produto.55 1 / 0.5 .125 12.5 3 / 2.5 2.5 .25 2.33 / 0.5 .5 / 5.5 .5 1.5 1.420 42 .5 / 9.420 350 / 260 400 / 300 - FNH3-630U FNH3-630U - 630 630 - 2 x CWM630-22-30¨ 2 x CWM500-22-30¨ 2 x CWM500-22-30¨ 2 x CWM630-22-30¨ 2 x CWM630-22-30¨ 2 x CWM800-22-30¨ SRW01-UMC5 SRW01-UMC6 SRW01-UMC6 SRW01-UMC6 SRW01-UMC6 SRW01-UMC6 42 .25 12.1 FDW-6S 6 2 x CWM9-10-30¨ SRW01-UMC1 0.25 10 / 7.5 1.75 / 0.5 .1 2 / 1.33 / 0.5 . regime de serviço contínuo S1.5 .weg.5 .5 FDW-10S 10 2 x CWM9-10-30¨ SRW01-UMC1 0.12.25 / 0.18 0.16 / 0.125 12.5 / 1. F2. S1: Botões de comando BLIM. 250VCC/240VCA M M Comando S0 S0 S1 S1 I1 S2 S2 I2 I1 K1 K1 I3 I3 F22 F22 110 .240 V VCA/VCC CA / V CC 110-240 ou ou VCA/VCC 2424V CA / V CC K2 K2 I4 IC A2 A2 A1 A1 SRW01-UC SRW01 . F3: Fusíveis K1.UMC T1 T2 T3 U U V V W W 3 O1 O2 C3 O3 C4 O4 A1 A2 F21 Tensão máx.02: Intertravamento elétrico e mecânico . máx. K2: Contatores SRW01-UC: Unidade de controle do relé inteligente SRW01-CB: Cabo de interligação UC+UMC SRW01-UMC: U  nidade de medição de corrente do relé inteligente M: Motor elétrico assincrono trifásico F21.CB SRW01-CB SRW01-UMC SRW01 .UC SRW01 . F22: Fusíveis de comando S0.weg.CB SRW01-CB C1 C1 K1 K1 O1 O1 O2 O2 C3 C3 O3 O3 C4 C4 O4 O4 A1 A1 A2 A2 F21 F21 Tensão máx.www. 250 250VCC/240VCA Tensão V CC / 240 V CA 16 Guia de Seleção de Partidas Descrição F1.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Fusíveis + Contatores + Relé de sobrecarga inteligente Diagramas de Ligação Potência L2 F1 F1 L3 F2 F2 F3 F3 S0 S1 I1 S2 I2 K1 I3 F22 L1 110-240 VCA/VCC ou 24 VCA/VCC K2 I4 IC A2 A1 SRW01-UC K1 1 3 5 2 4 6 K2 K2 1 3 5 2 4 6 SRW01-CB C1 L1 L1 L2 L2 L3 L3 K1 SRW01 . 112 3 / 2.3 2 x CWM9-10-30¨ RW27-1D3-D063 4 .5 8 .weg.310 DWM400H-320-3 320 2 x CWM300-22-30¨ RW317-1D3-U310 200 .33 / 0.5 / 1.2 .33 / 0.33 / 0.1 3 / 2.7 6 / 4.55 1 / 0.8 1.5 MPW25i-3-U004 4 2 x CWM9-10-30¨ RW27-1D3-U004 2.18 0.5 / 5.1.5 / 1.5 / 1.5 7.70 63 .2 4/3 5 / 3.5 / 9.5 / 9.18 0.12 0.25 / 0.5 10 / 7.55 1 / 0.5 10 / 7.840 560 .50 40 .25 - 0.15 11 .56 .16 / 0.4 . 3) Limitada pelas características técnicas do disjuntor-motor e do relé de sobrecarga.10 8 .40 MPW65i-3-U040 MPW65i-3-U050 MPW65i-3-U050 MPW65i-3-U065 MPW65i-3-U065 MPW65i-3-U065 DWB160N80-3MF DWB160N95-3MF DWB250N105-3MF 40 50 50 65 65 65 80 95 105 2 x CWM40-11-30¨ 2 x CWM50-11-30¨ 2 x CWM50-11-30¨ 2 x CWM65-11-30¨ 2 x CWM65-11-30¨ 2 x CWM65-11-30¨ 2 x CWM80-11-30¨ 2 x CWM95-11-30¨ 2 x CWM105-11-30¨ RW67-1D3-U050 RW67-2D3-U050 RW67-2D3-U057 RW67-2D3-U057 RW67-2D3-U063 RW67-2D3-U070 RW67-2D3-U080 RW117-1D3-U097 RW117-1D3-U112 32 . Motores em outras condições.2.8 1.4 MPW25i-3-D063 6.16 / 0.8 5.8 2 / 1.12 0.5 2 x CWM9-10-30¨ RW27-1D3-D018 1.3 10 10 10 16 16 16 16 20 20 25 32 32 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM12-10-30¨ 2 x CWM12-10-30¨ 2 x CWM12-10-30¨ 2 x CWM18-10-30¨ 2 x CWM18-10-30¨ 2 x CWM18-10-30¨ 2 x CWM25-10-30¨ 2 x CWM25-10-30¨ 2 x CWM32-10-30¨ 2 x CWM32-10-30¨ RW27-1D3-U008 RW27-1D3-U008 RW27-1D3-U010 RW27-1D3-D125 RW27-1D3-D125 RW27-1D3-U015 RW27-1D3-U015 RW27-1D3-U017 RW27-1D3-U017 RW27-1D3-U017 RW27-1D3-U032 RW27-1D3-U032 RW67-1D3-U040 5.5 / 9.2 0.AC-3 1) Disjuntor-motor magnético Referência Corrente nominal (A) 0. Guia de Seleção de Partidas 17 .75 / 0.55 1 / 0.12.600 DWM1600H-700-3 DWM1600H-700-3 700 700 2 x CWM630-22-30¨ 2 x CWM800-22-30¨ RW407-1D3-U840 RW407-1D3-U840 560 .75 / 0.8 .5 12.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 DWB250N150-3MF 150 2 x CWM150-22-30¨ RW317-1D3-U150 100 .310 300 / 220 DWM800H-420-3 420 2 x CWM400-22-30¨ RW317-1D3-U420 275 .5 12.63 1 1.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico Características g Proteção  contra curto-circuito e seccionamento com possibilidade de bloqueio mecânico para evitar religamento do circuito g Disparador  magnético fixo e calibrado em 12 e 13 vezes a corrente máxima do disjuntor g Disparador  térmico ajustável para proteção contra sobrecargas através do relé de sobrecarga g Operação  automática/remota através do contator g Elevada  vida útil devido a utilização do contator para manobra g Aplicável  a motores que partem a vazio ou a plena carga g Frequência  de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .2 4/3 5 / 3.8 .5 1.0.1.23 22 .5 10 . regime de serviço contínuo S1.5 12.75 / 0.600 DWM1600H-700-3 700 2 x CWM630-22-30¨ RW407-1D3-U600 400 .6 2 x CWM9-10-30¨ RW27-1D3-D018 1.420 350 / 260 400 / 300 450 / 330 500 / 370 - DWM800H-420-3 DWM800H-420-3 DWM800H-500-3 420 420 500 2 x CWM500-22-30¨ 2 x CWM500-22-30¨ 2 x CWM500-22-30¨ RW317-1D3-U420 RW407-1D3-U600 RW407-1D3-U600 275 .2 4/3 5 / 3.50 32 . fator de serviço igual a 1 em redes de 60 Hz.5 4 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ RW27-1D3-D028 RW27-1D3-D028 1.75 0.8 220 V cv / kW 380 V cv / kW 440 V cv / kW 0.7 6 / 4.840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.2 .32 22 .5 / 5.8 7 .5 10 / 7.6 .37 0.12 0. analisar os dados de corrente nominal de serviço e corrente de partida.5 / 0.37 0.12.6 Contator 2) Referência básica para completar com a tensão de comando 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ 2 x CWM9-10-30¨ MPW25i-3-D016 1.2.8 .5 / 0.0.5 3 / 2.1.63 0.5 15 / 11 20 / 15 25 / 18.2 2 / 1.1 2 / 1.6.5 7.600 400 .150 DWB250N185-3MF DWM400H-250-3 185 250 2 x CWM180-22-30¨ 2 x CWM250-22-30¨ RW317-1D3-U215 RW317-1D3-U215 140 .8 .57 50 .2 15 / 11 20 / 15 - 25 / 18.800 rpm).5 / 5.75 MPW25i-3-C063 MPW25i-3-C063 MPW25i-3-U001 MPW25i-3-D016 0.17 15 .420 400 .7 6 / 4.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 - 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 100 / 75 175 / 132 125 / 90 200 / 150 250 / 185 300 / 220 350 / 260 150 / 110 175 / 132 200 / 150 - 400 / 300 250 / 185 300 / 220 450 / 330 500 / 370 Relé de sobrecarga Referência Faixa de ajuste (A) RW27-1D3-C063 RW27-1D3-D008 RW27-1D3-D012 RW27-1D3-D012 0.32 25 .40 MPW65i-3-U040 40 2 x CWM40-11-30¨ RW67-1D3-U040 25 .2 - MPW25i-3-D025 2.2 15 / 11 20 / 15 25 / 18.25 / 0.75 1.17 11 .15 10 .97 90 .1 - MPW25i-3-D025 MPW25i-3-U004 2.25 0.57 40 .16 / 0.25 / 0.1.3 MPW25i-3-D063 MPW25i-3-U010 MPW25i-3-U010 MPW25i-3-U010 MPW25i-3-U016 MPW25i-3-U016 MPW25i-3-U016 MPW25i-3-U016 MPW25i-3-U020 MPW25i-3-U020 MPW25i-3-U025 MPW25i-3-U032 MPW25i-3-U032 6.215 140 .6 .8 0.8 .25 0.18 0.5 7.63 57 . 2) Código das tensões de comando disponíveis no catálogo específico do produto.5 / 0.63 0.215 DWM400H-250-3 250 2 x CWM250-22-30¨ RW317-1D3-U310 200 .www.37 0.80 75 . 02 A2 A2 Guia de Seleção de Partidas K2 K2 13 13 14 14 32 32 A1 A1 K2 K2 A2 A2 FT1 FT1 95 95 96 96 Descrição Q1: Disjuntor-motor magnético K1. F22: Fusíveis de comando S1.02 BLIM.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico Diagramas de Ligação Potência L1 L1 L2 L2 L3 11 3 3 5 5 A F21 B F22 Q1 Q1 I> I> 2 I> I> 4 S0 > II> 66 1 2 AA B B K1 K1 11 3 55 22 4 66 K2 K2 1 3 55 2 4 66 S1 3 4 21 K2 1 33 13 S2 K1 K2 4 14 BLIM.02: Intertravamento elétrico e mecânico F21.02 BLIM. S2.02 FT1 A1 K1 K2 A2 A2 M 3~ 3 Comando A A F21 F21 B B F22 F22 S0 S0 S1 S1 K2 K2 K1 K1 18 11 22 33 K1 K1 13 13 S2 S2 33 44 14 14 44 21 21 BLIM. K2: Contatores FT1: Relé de sobrecarga térmico M: Motor elétrico assincrono trifásico BLIM.02 14 31 K1 22 13 3 32 55 FT1 FT1 A1 2 44 66 U1 U1 V1 W1 W1 W1 BLIM.www. S0: Botões de comando 95 96 .weg.02 31 31 K1 K1 22 22 A1 A1 BLIM. 5 .25 / 0.33 / 0. analisar os dados de corrente nominal de serviço e corrente de partida.5 20 / 15 25 / 18.2 15 / 11 - 4/3 4/3 5 / 3.125 12.33 / 0.125 MPW65i-3-U050 50 2 x CWM50-11-30¨ SRW01-UMC4 12.125 12.AC-3 220 V cv / kW 0.75 1.75 / 0.37 0.16 / 0.5 .125 42 .5 .5 12.5 / 0.5 / 5.5 / 1.5 MPW25i-3-D016 1.5 .5 7.5 5 / 3.840 DWM1600H-700-3 700 2 x CWM630-22-30¨ SRW01-UMC6 84 .55 1 / 0.5 .25 0.5 / 9.7 6 / 4.25 / 0.5 MPW25i-3-U010 MPW25i-3-U016 10 16 2 x CWM12-10-30¨ 2 x CWM12-10-30¨ SRW01-UMC2 SRW01-UMC2 1.5 1. Motores em outras condições. Consulte catálogo específico do produto.18 0.7 10 / 7.5 2 / 1.5 .5 2 x CWM9-10-30¨ SRW01-UMC1 0.5 .420 DWM400H-320-3 320 2 x CWM300-22-30¨ SRW01-UMC5 42 .5 .5 . 4) Limitada pelas características técnicas do disjuntor-motor.25 2.18 0.63 2 x CWM9-10-30¨ SRW01-UMC1 0. 3) Código das tensões de comando disponíveis no catálogo específico do produto.5 .840 DWM1600H-700-3 700 2 x CWM800-22-30¨ SRW01-UMC6 84 .5 MPW25i-3-U001 1 2 x CWM9-10-30¨ SRW01-UMC1 0.18 0.5 1) 380 V cv / kW 440 V cv / kW 0.5 7.5 30 / 22 40 / 30 40 / 30 50 / 37 MPW65i-3-U065 65 2 x CWM65-11-30¨ SRW01-UMC4 12.5 / 9.420 3 / 2. tensão de entradas digitais e tensão de alimentação.5 .5 .16 / 0.5 6 / 4.25 MPW25i-3-U020 MPW25i-3-U020 MPW25i-3-U025 20 20 25 2 x CWM18-10-30¨ 2 x CWM25-10-30¨ 2 x CWM25-10-30¨ SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 2. regime de serviço contínuo S1.55 1 / 0.1 2 / 1.12.5 .37 0.25 MPW25i-3-U032 32 2 x CWM32-10-30¨ SRW01-UMC4 12.25 0. código do tipo de proteção.5 1.840 84 .75 / 0.840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.33 / 0. 2) Referência básica para substituir “˜” por código do protocolo de comunição.5 12.5 / 5.5 .5 .2 4/3 5 / 3.5 / 0.12 0.5 / 9.1 2 / 1.75 0.5 .5 / 1.25 2.weg.5 MPW25i-3-U016 16 2 x CWM18-10-30¨ SRW01-UMC3 2.125 MPW65i-3-U040 40 2 x CWM40-11-30¨ SRW01-UMC4 12.55 1 / 0.5 / 5.5 MPW25i-3-U004 4 2 x CWM9-10-30¨ SRW01-UMC1 0.12.125 3 / 2.420 42 .7 6 / 4.5 7.6 2 x CWM9-10-30¨ SRW01-UMC1 0.75 / 0.5 / 0.12 0.25 0.5 3 / 2.5 10 / 7.5 MPW25i-3-D063 6.5 / 1.3 2 x CWM9-10-30¨ SRW01-UMC2 1.12.5 .12.2 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 20 / 15 20 / 15 DWM400H-250-3 250 2 x CWM250-22-30¨ SRW01-UMC5 42 .5 MPW25i-3-U010 10 2 x CWM9-10-30¨ SRW01-UMC2 1.5 .www.16 / 0.420 350 / 260 400 / 300 450 / 330 500 / 370 - DWM800H-420-3 DWM800H-420-3 DWM800H-500-3 420 420 500 2 x CWM500-22-30¨ 2 x CWM500-22-30¨ 2 x CWM500-22-30¨ SRW01-UMC5 SRW01-UMC6 SRW01-UMC6 42 .5 .37 0.75 1.2 Disjuntor-motor magnético Referência Corrente nominal (A) Contator 2) Referência básica para completar com a tensão de comando SRW01-UC-˜ 2) + Unidade de medição Unidade de medição Faixa de ajuste (A) Referência MPW25i-3-C063 0.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 30 / 22 25 / 18.2 15 / 11 15 / 11 25 / 18.5 .25 / 0.800 rpm). fator de serviço igual a 1 em redes de 60 Hz.125 12.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga inteligente Características g Proteção  contra curto-circuito através do disjuntor-motor magnético g Disparador  térmico ajustável com classe de disparo de 5 a 45 para proteção contra sobrecargas através do relé inteligente g Operação  automática/remota através do contator g Elevada  vida útil devido a utilização do contator para manobra g Aplicável  a motores que partem a vazio ou a plena carga g Frequência  de manobras: 15 manobras/hora 4) Tabela orientativa de motores trifásicos .12 0.420 300 / 220 DWM800H-420-3 420 2 x CWM400-22-30¨ SRW01-UMC5 42 .5 10 / 7.2 12.5 .1 MPW25i-3-D025 2.125 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 350 / 260 400 / 300 450 / 330 500 / 370 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 DWB160N80-3MF DWB160N95-3MF DWB250N105-3MF DWB250N150-3MF DWB250N150-3MF DWB250N185-3MF 80 95 105 150 150 185 2 x CWM80-11-30¨ 2 x CWM95-11-30¨ 2 x CWM105-11-30¨ 2 x CWM150-22-30¨ 2 x CWM150-22-30¨ 2 x CWM180-22-30¨ SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC5 SRW01-UMC5 12.420 84 . Guia de Seleção de Partidas 19 . 240 V VCA/VCC CA / V CC ou 24 / V CC 24V CA VCA/VCC K2 K2 I3 I3 I4 I4 IC IC A2 A1 A1 SRW01 . 250VCC/240VCA T1 U U 3 T2 T3 V V W W M Comando S0 S0 S1 S1 I1 I1 S2 S2 I2 K1 K1 F22 F22 110-240 110 .weg. S0: Botões de comando BLIM.CB 3 5 4 6 C1C1 K1 K1 O1 O1 C3 C3 O2 O2 O3 O3 C4 C4 O4 O4 A1 A1 A2 F21 F21 Tensãomáx.UC SRW01-UC SRW01-CB SRW01 .CB SRW01-CB SRW01-UMC SRW01 . F22: Fusíveis de comando S1. S2. Tensão 250250VCC/240VCA V CC / 240 V CA 20 Guia de Seleção de Partidas Descrição Q1: Disjuntor magnético K1.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão em regime AC-3 Composição: Disjuntor-motor magnético + Contatores + Relé inteligente Diagramas de Ligação Potência 11 L3 3 5 > II> > II> > II> 22 4 6 Q1 F1 S0 S1 I1 S2 I2 K1 I3 F22 L1 L2 L2 L1 110-240 VCA/VCC ou 24 VCA/VCC K2 I4 IC A2 A1 SRW01-UC K1 K1 1 3 5 2 4 6 K2 1 1 3 5 5 2 4 6 SRW01-CB C1 L1 L1 L2 L3 K1 O2 C3 O3 C4 O4 A1 A2 F21 SRW01 .UMC O1 Tensão máx.www. K2: Contatores FT1 : Relé de sobrecarga M: Motor elétrico assincrono trifásico F21. máx.02: Intertravamento elétrico e mecânico . 75 MPW25-3-D016 1 .25 0. fator de serviço igual a 1 em redes de 60 Hz.5 / 1.5 12.5 3 / 2.6 2 x CWM9-10-30¨ 1.3 .0.5 30 / 22 40 / 30 12.5 7.5 / 0.25 2 x CWM18-10-30¨ 2 x CWM25-10-30¨ 2 x CWM25-10-30¨ 20 / 15 20 / 15 MPW25-3-U032 25 .5 10 / 7.16 2 x CWM12-10-30¨ 2 x CWM12-10-30¨ MPW25-3-U016 10 .20 20 .40 32 .5 6 / 4.7 6 / 4.32 2 x CWM32-10-30¨ 25 / 18. Motores em outras condições.3 .5 / 0.50 2 x CWM40-11-30¨ 2 x CWM40-11-30¨ 2 x CWM50-11-30¨ 2 x CWM50-11-30¨ 40 / 30 50 / 37 MPW65-3-U065 50 .5 30 / 22 40 / 30 - MPW25-3-U032 MPW65-3-U040 MPW65-3-U040 MPW65-3-U050 25 . 2) Código das tensões de comando disponíveis no catálogo específico do produto.10 10 .2 15 / 11 20 / 15 25 / 18.25 / 0.6 .37 0.5 / 0.5 / 1.5 0.7 10 / 7.5 / 5.5 3 / 2.16 / 0.90 70 .75 1.5 5 / 3. regime de serviço contínuo S1.1 MPW25-3-D025 1.5 2 x CWM9-10-30¨ 220 V cv / kW 0.1 2 / 1.1 2 / 1.5 / 1.55 1 / 0.75 / 0.33 / 0.37 0.65 2 x CWM65-11-30¨ 50 / 37 60 / 45 - 60 / 45 75 / 55 - MPW100-3-U075 MPW100-3-U090 MPW100-3-U090 MPW100-3-U0100 55 .4 .5 12.20 16 .18 0.18 0.63 2 x CWM9-10-30¨ 0.5 / 9.2 2 / 1.4 2 x CWM9-10-30¨ MPW25-3-D063 4 .10 2 x CWM9-10-30¨ MPW25-3-U010 MPW25-3-U016 6.7 6 / 4.16 / 0.AC-3 1) Disjuntor-motor termomagnético Contator 2) Referência básica para completar com a tensão de comando 380 V cv / kW 440 V cv / kW Referência Faixa de ajuste (A) - 0.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Disjuntor-motor termomagnético + Contatores Características g Proteção  contra curto-circuito e seccionamento com possibilidade de bloqueio mecânico para evitar religamento do circuito g Disparador  magnético fixo e calibrado em 13 vezes a corrente máxima do disjuntor g Disparador  térmico ajustável para proteção contra sobrecargas incorporado no disjuntor g Operação  automática/remota através do contator g Elevada  vida útil devido a utilização do contator para manobra g Aplicável  a motores que partem a vazio ou a plena carga g Frequência  de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .800 rpm).18 0.2 4/3 4/3 5 / 3.75 70 .25 MPW25-3-U001 0.5 / 5. 3) Limitada pelas características técnicas do disjuntor-motor e do relé de sobrecarga.3 2 x CWM9-10-30¨ MPW25-3-U010 6.75 / 0.5 / 9.1.12 0.40 40 .2 15 / 11 - MPW25-3-U004 2.55 1 / 0.12 MPW25-3-C063 0.5 / 9.32 32 .25 / 0.5 10 / 7.6.1 2 x CWM9-10-30¨ 0. Guia de Seleção de Partidas 21 .weg. analisar os dados de corrente nominal de serviço e corrente de partida.5 / 5.16 / 0.2.5 7.5 30 / 22 25 / 18.25 0.55 1 / 0.100 2 x CWM80-11-30¨ 2 x CWM80-11-30¨ 2 x CWM95-11-30¨ 2 x CWM105-11-30¨ Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.16 2 x CWM18-10-30¨ MPW25-3-U020 MPW25-3-U020 MPW25-3-U025 16 .33 / 0.33 / 0.63 .5 .12 0.www.5 7.75 1.90 80 .2 15 / 11 3 / 2.37 0.75 / 0.2 4/3 5 / 3.25 / 0. 02: Intertravamento elétrico e mecânico F21.02 BLIM.02 A2 A2 Guia de Seleção de Partidas 13 13 K2 K2 32 32 A1 A1 K2 K2 A2 A2 14 31 K1 U1 K2 4 14 22 13 3 14 14 Descrição Q1: Disjuntor-motor termomagnético K1.02 31 31 K1 K1 22 22 A1 A1 S2 S2 BLIM.02 BLIM.weg.net Guia de Seleção de Partidas Tipo da partida: Direta com reversão Composição: Disjuntor-motor termomagnético + Contatores Diagramas de Ligação Potência L1 L1 L2 L2 1 3 L3 L3 55 A F21 B F22 Q1 S0 II> > I> I> 2 44 2 I> I> 66 1 AA B B K1 K1 1 33 55 2 44 6 K2 K2 1 3 5 2 4 6 S1 3 4 21 K2 13 S2 K1 A1 BLIM. K2: Contatores M: Motor elétrico assincrono trifásico BLIM.02 V1 W1 K1 BLIM.www.02 32 A1 K2 A2 M 3~ 3 Comando A A F21 F21 B F22 F22 S0 S0 S1 S1 1 22 33 44 21 21 K2 K2 K1 K1 22 13 13 K1 K1 33 14 14 44 BLIM. S1 e S2: Botões de comando A2 . F22: Fusíveis de comando S0. 7 6/4. 2) Substituir “¨” pelo código das tensões de comando disponíveis no catálogo específico do produto e substituir “g” pelas seguintes configurações de contatos auxiliares: 20 (K1) e 11 (K2).5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 350/260 400/300 450/330 500/370 - Fusíveis tipo retardado 5) Referência tamanhos D/NH Corrente nominal (A) Contator 2) Referência básica para completar com a tensão de comando Relé de sobrecarga K1 = K2 K3 Referência Faixa de ajuste (A) FDW-10S 10 CWM9-g-30¨ CWM9-11-30¨ RW27-1D3-D063 4 . 3) Limitada pelas características técnicas do relé de sobrecarga.15 10 .2 15/11 20/15 25/18.23 15 .2 15/11 20/15 25/18. Guia de Seleção de Partidas 23 .3 FDW-16S FDW-16S FDW-16S FDW-20S FDW-20S FDW-25S FDW-25S FDW-35S FDW-35S 2 x FDW-25S FDW-50S FDW-50S FDW-50S 2 x FDW-35S FDW-50S FDW-63S FDW-63S FNH000-80U FNH00-100U FNH00-100U FNH00-125U FNH00-125U FNH00-125U FNH00-125U 2 x FNH00-100U 2 x FNH00-100U 2 x FNH00-100U 2 x FNH00-125U 2 x FNH00-125U FNH1-224U 2 x FNH1-200U FNH1-250U 2 x FNH1-200U 2 x FNH1-200U 2 x FNH1-224U 2 x FNH1-250U 2 x FNH2-300U 16 16 16 20 20 25 25 35 35 25 50 50 50 35 50 63 63 80 100 100 125 125 125 125 100 100 100 125 125 224 200 250 200 200 224 250 300 CWM9-g-30¨ CWM9-g-30¨ CWM9-g-30¨ CWM9-g-30¨ CWM12-g-30¨ CWM12-g-30¨ CWM12-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM95-g-30¨ CWM105-g-30¨ CWM105-g-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM12-11-30¨ CWM12-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM32-11-30¨ CWM32-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM80-00-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM105-22-30 CWM150-22-30¨ CWM150-22-30¨ RW27-1D3-D063 RW27-1D3-U008 RW27-1D3-U010 RW27-1D3-U010 RW27-1D3-D125 RW27-1D3-D125 RW27-1D3-U015 RW27-1D3-U015 RW27-1D3-U017 RW27-1D3-U023 RW27-1D3-U023 RW27-1D3-U023 RW27-1D3-U032 RW27-1D3-U032 RW27-1D3-U032 RW27-1D3-U032 RW67-1D3-U040 RW67-1D3-U050 RW67-2D3-U050 RW67-2D3-U057 RW67-2D3-U050 RW67-2D3-U057 RW67-2D3-U063 RW67-2D3-U070 RW67-2D3-U080 RW67-2D3-U080 RW117-1D3-U097 RW117-1D3-U097 RW117-1D3-U112 RW117-1D3-U112 RW317-1D3-U150 RW317-1D3-U150 RW317-1D3-U150 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U310 4 .23 15 . Motores em outras condições.150 100 .weg.5/5.15 11 .7 5/3.57 32 .70 63 .310 2 x FNH2-355U 355 CWM300-22-30¨ CWM180-22-30¨ RW317-1D3-U310 200 .32 22 .40 25 .5 7.5 6/4. fator de serviço igual a 1 em redes de 60 Hz.40 32 .5 10/7. analisar os dados de corrente nominal de serviço e corrente de partida.5/5.63 57 .5/9.5 12.5 12.5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 350/260 250/185 300/220 350/260 400/300 450/330 500/370 400/300 450/330 500/370 - 1) 440 V cv / kW 5/3.150 140 .5 7.32 22 .112 100 .420 400 .5 10 . regime de serviço contínuo S1.5 10/7.112 90 .17 15 . 4) Para temporização utilizar os temporizadores eletrônicos modelos: RTW-ET02-U030S ● (códigos de tensão disponíveis no catálogo específico do produto).2 15/11 20/15 25/18.310 2 x FNH2-400U 2 x FNH2-400U 2 x FNH3-425U 2 x FNH3-500U 2 x FNH3-630U - 400 400 425 500 630 800 800 800 CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM500-22-30¨ CWM630-22-30¨ CWM630-22-30¨ CWM800-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ RW317-1D3-U420 RW317-1D3-U420 RW317-1D3-U420 RW317-1D3-U420 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U840 RW407-1D3-U840 275 .12.5/9.net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Fusíveis + Contatores + Relé de sobrecarga térmico Características g  Proteção contra curto-circuito através dos fusíveis tipo gL/gG g  Disparador térmico ajustável para proteção contra sobrecargas através do relé de sobrecarga g  Operação automática/remota através do contator g  Elevada vida útil devido a utilização do contator para manobra g  Aplicável a motores que partem a vazio ou a cargas de baixa inércia Tabela orientativa de motores trifásicos .215 200 .6 .215 140 .23 22 .AC-3 220 V cv / kW 380 V cv / kW - 5/3.5 12.150 100 .6.80 63 .800 rpm).5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 7.215 140 .10 8 .50 40 .5 8 .840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.www. Consulte catálogo específico do produto.12.10 7 .5 10/7.57 50 . 5) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras.420 275 .80 75 .600 400 .7 6/4.6.32 22 .97 90 .3 5.32 25 .8 7 .97 75 .840 560 .420 275 .600 560 .5/5.5/9.420 275 .50 40 . F5. 175 cv (380 V CA) e 250 cv (440 V CA) W2 W2 Comando F21 F21 AA F22 F22 BB FT1 FT1 95 96 95 96 S0 S0 S1 S1 11 22 33 44 K1 K1 KT1 KT1 13 13 14 14 K3 K3 13 13 14 14 15 15 K1 K1 KT1 KT1 18 18 21 21 K2 K2 KT1 KT1 24 A1 A1 A2 A2 K3 K3 K3 K3 22 22 A1 A1 A2 A2 K1 K1 A1 A1 A2 A2 Guia de Seleção de Partidas K2 K2 43 43 44 44 25 25 28 28 21 21 22 22 A1 A1 A2 A2 K2 K2 13 13 14 14 Descrição F1. F2. F6: Fusíveis K1. F3.weg. F4. S1: Botões de comando KT1: Relé eletrônico temporizador Y-Δ KT1 A2 . K2. F22: Fusíveis de comando S0. K3: Contatores FT1: Relé de sobrecarga térmico M: Motor elétrico assincrono trifásico F21.net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Fusíveis + Contatores + Relé de sobrecarga térmico Diagramas de Ligação Potência L1 L1 L2 L2 L3 L3 B FT1 A F1 F1 F2 F2 F3 F3 F4 F4 F5 F5 B F6 F6 F21 95 96 F22 S0 1 2 A 3 S1 4 AA B B 11 33 1 5 K1 K1 33 55 K2 K2 22 44 6 11 33 5 22 44 6 11 33 5 22 44 6 K3 K3 2 44 6 FT1 FT1 U1 U1 V2 M M 33~ V1 V1 W1 W1 A1 U2 U2 A - Diagrama elétrico padrão B - Diagrama para potências 125 cv (220 V CA).www. 12.125 12.5 10 / 7. Motores em outras condições.5 12.5 7.5 / 9.840 - - - 800 CWM630-22-30¨ CWM400-22-30¨ SRW01-UMC6 84 .420 42 .420 42 .420 g CWM12-g-30¨ CWM12-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM95-g-30¨ CWM105-g-30¨ CWM105-g-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ 2 x FNH2-355U 355 CWM300-22-30¨ CWM180-22-30¨ SRW01-UMC5 42 .5 .5 1.12. tensão de entradas digitais e tensão de alimentação.420 42 .840 - - - 800 CWM800-22-30¨ CWM400-22-30¨ SRW01-UMC6 84 .125 12.25 .5 .5 10 / 7.2 15 / 11 20 / 15 25 / 18.net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Fusíveis + Contatores + Relé de sobrecarga inteligente Características g  Proteção contra curto-circuito através dos fusíveis tipo gL/gG g  Disparador térmico ajustável com classe de disparo de 5 a 45 para proteção contra sobrecargas através do relé de sobrecarga inteligente g  Operação automática/remota através do contator g  Elevada vida útil devido a utilização do contator para manobra g  Aplicável a motores que partem a vazio ou cargas de baixa inércia Tabela orientativa de motores trifásicos .420 42 .5 .25 .7 5 / 3.5 .2 15 / 11 20 / 15 25 / 18.25 2.12.5 .125 12.5 / 5.420 42 .125 42 .5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 350 / 260 400 / 300 450 / 330 500 / 370 - Fusíveis tipo retardado 4) Contator 2) Referência básica para completar com a tensão de comando K1 = K2 K3 SRW01-UC-˜ 3) + Unidade de medição Unidade de medição Faixa de ajuste (A) Referência Referência tamanhos D/NH Corrente nominal (A) FDW-10S 10 CWM9-g-30¨ CWM9-11-30¨ SRW01-UMC1 0.5 .5 / 5.5 FDW-20S FDW-20S FDW-25S FDW-35S 2 x FDW-25S FDW-50S FDW-50S 2 x FDW-35S FDW-50S FDW-63S FNH000-80U FNH00-100U FNH00-125U FNH00-125U FNH00-125U 2 x FNH00-100U 2 x FNH00-100U 2 x FNH00-100U 2 x FNH00-125U 2 x FNH00-125U FNH1-224U 2 x FNH1-200U FNH1-250U 2 x FNH1-200U 2 x FNH1-200U 2 x FNH1-224U 2 x FNH1-250U 2 x FNH2-300U 20 20 25 35 25 50 50 35 50 63 80 100 125 125 125 100 100 100 125 125 224 200 250 200 200 224 250 300 CWM9-g-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM12-11-30¨ CWM12-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM32-11-30¨ CWM32-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM80-00-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM105-22-30¨ CWM150-22-30¨ CWM150-22-30¨ SRW01-UMC2 SRW01-UMC2 SRW01-UMC2 SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMCT5 SRW01-UMC4 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 1.-30¨ CWM9-11-30¨ SRW01-UMC2 1.5 .2 15 / 11 20 / 15 25 / 18.7 6 / 4.125 12.5 10 / 7. Consulte catálogo específico do produto.7 6 / 4.5 .420 42 .5 / 5.800 rpm).125 12.125 12.125 12.125 12.5 . código do tipo de proteção.125 12.5 . analisar os dados de corrente nominal de serviço e corrente de partida.125 12.125 12.25 2.25 2.weg. 3) Referência básica para substituir “˜” por código do protocolo de comunição.5 / 9.5 7.420 12.5 2.5 .5 12.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 6 / 4.12. 2) Substituir “¨” pelo código das tensões de comando disponíveis no catálogo específico do produto e substituir “ g ” pelas seguintes configurações de contatos auxiliares: 20 (K1) e 11 (K2).25 .AC-3 220 V cv / kW 380 V cv / kW - 5 / 3.25 12. fator de serviço igual a 1 em redes de 60 Hz.420 42 .125 42 . 4) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras. regime de serviço contínuo S1.5 .25 . Guia de Seleção de Partidas 25 .420 84 .5 .5 .420 2 x FNH2-400U 2 x FNH2-400U 2 x FNH3-425U 2 x FNH3-500U 2 x FNH3-630U 400 400 425 500 630 CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM500-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC6 42 .www.5 .5 / 9.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 200 / 150 350 / 260 250 / 185 300 / 220 350 / 260 400 / 300 450 / 330 500 / 370 400 / 300 450 / 330 500 / 370 - 1) 440 V cv / kW 5 / 3.5 .25 2.5 .5 .5 FDW-16S 16 CWM9.5 7.5 12.5 .840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.5 1.5 . Consulte catálogo específico do produto.25 2. F5.UC SRW01 .www. F22: Fusíveis de comando S0.UMC SRW01-UMC 3 3 3 K2 K1 K1 1 S1 2 13 F22 F1 F1 Guia de Seleção de Partidas Descrição F1. F6: Fusíveis K1.250 250VCC/240VCA Tensão V CC / 240 V CA 26 O4 A1 A - Diagrama elétrico padrão B - Diagrama para potências 125 cv (220 V CA).weg.240 VVCA/VCC CA / V CC ou 24 VVCA/VCC 24 CA / V CC 11 S1 S1 22 I1 I1 33 44 K2 K2 I2 I2 13 13 F22 F22 S0 S0 14 14 13 13 K3 K3 13 13 14 14 14 14 I3 I3 I4 I4 IC IC A2 A1 A1 SRW01-UC SRW01 . 250VCC/ Comando 110-240 110 . 175 cv (380 V CA) e 250 cv (440 V CA) W2 W2 K1 K1 C4 F21 U2 U2 M A1 SRW01-UC V2 V2 3 A2 SRW01-CB K1 V1 V1 6 3 3 T3 U1 U1 4 1 1 SRW01 .net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Fusíveis + Contatores + Relé de sobrecarga inteligente Diagramas de Ligação Potência L1 L2 L2 L3 L3 B B 110-240 VCA/VCC ou 24 VCA/VCC F2 F2 F4 F4 F3 F5 F5 F6 F6 K1 S0 A A 1 1 3 3 1 1 5 5 2 2 4 4 6 6 L1 L1 L2 L2 L3 L3 T2 T2 5 5 4 4 66 2 2 4 4 6 6 3 I1 I2 14 4 K2 13 K3 13 14 14 I3 I4 IC C1 O1 O2 A1 A1 A2 A2 K2 C3 K3 O3 W1 W1 A2 Tensão máx. F3. K2. F4.CB SRW01-CB T1 T1 5 5 5 K3 K3 22 SRW01 . S1: Botões de comando . K3: Contatores SRW01-UC: Unidade de controle do relé inteligente SRW01-CB: Cabo de interligação UC+UMC SRW01-UMC: Unidade de medição de corrente do relé inteligente M: Motor elétrico assincrono trifásico F21. máx.CB SRW01-CB C1 C1 K1 K1 O1 O1 A1 A1 K2 K2 A2 A2 O2 O2 C3 C3 A1 A1 A2 A2 K3 K3 O3 O3 C4 C4 O4 O4 A1 A1 A2 A2 F21 F21 Tensão máx. F2. 5 10 / 7.5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 350/260 400/300 450/330 - Disjuntor-motor magnético Referência Corrente nominal (A) Contator 2) Referência básica para completar com configuração de contatos auxiliares e tensão de comando Relé de sobrecarga K1 = K2 K3 Referência Faixa de ajuste (A) MPW16i-3-U010 10 CWM9-g-30¨ CWM9-11-30¨ RW27-1D3-D063 4 .840 560 .5 10 .215 140 . fator de serviço igual a 1 em redes de 60 Hz.40 25 .2 15/11 20/15 25/18.5 7.50 40 .310 200 .5 7. Guia de Seleção de Partidas 27 .40 32 .800 rpm).23 22 .112 100 . 4) Para temporização utilizar os temporizadores eletrônicos modelos: RTW-ET02-U030S ● (códigos de tensão disponíveis no catálogo específico do produto).6.63 57 .150 100 . regime de serviço contínuo S1. Motores em outras condições.5 / 5.15 10 .10 8 .weg.5 12.32 22 .8 5.50 40 .57 50 .5 12.5 / 9.215 200 .215 140 . 3) Limitada pelas características técnicas do disjuntor-motor e relé de sobrecarga.5 10 / 7.5 12.840 Notas 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.12.2 15 / 11 20/15 25/18.5 / 9.3 MPW16i-3-U010 MPW16i-3-U016 MPW16i-3-U016 MPW16i-3-U016 MPW25i-3-U020 MPW25i-3-U020 MPW25i-3-U025 MPW25i-3-U032 MPW25i-3-U032 MPW25i-3-U032 MPW65i-3-U040 MPW65i-3-U040 MPW65i-3-U040 MPW65i-3-U050 MPW65i-3-U050 MPW65i-3-U065 MPW65i-3-U065 DWB160N-80-3MF DWB160N-80-3MF DWB160N-95-3MF DWB160N-95-3MF DWB250N105-3MF DWB250N105-3MF DWB250N150-3MF DWB250N150-3MF DWB250N-185-3MF DWM400H-250-3 DWM400H-250-3 DWM400H-320-3 DWM400H-320-3 DWM800H-420-3 DWM800H-420-3 DWM800H-500-3 DWM1600H-700-3 DWM1600H-700-3 10 16 16 16 20 20 25 32 32 32 40 40 40 50 50 65 65 80 80 95 95 105 105 150 150 185 250 250 320 320 420 420 500 700 700 CWM9-g-30¨ CWM9-g-30¨ CWM9-g-30¨ CWM12-g-30¨ CWM12-g-30¨ CWM12-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM105-g-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM12-11-30¨ CWM12-11-30¨ CWM12-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM32-11-30¨ CWM32-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM65-11-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM105-11-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM180-22-30¨ RW27-1D3-U008 RW27-1D3-U008 RW27-1D3-U010 RW27-1D3-D125 RW27-1D3-D125 RW27-1D3-U015 RW27-1D3-U015 RW27-1D3-U017 RW27-1D3-U023 RW27-1D3-U023 RW27-1D3-U023 RW27-1D3-U023 RW27-1D3-U032 RW27-1D3-U032 RW27-1D3-U032 RW67-1D3-U040 RW67-1D3-U040 RW67-2D3-U050 RW67-2D3-U057 RW67-2D3-U050 RW67-2D3-U057 RW67-2D3-U063 RW67-2D3-U070 RW67-2D3-U080 RW117-1D3-U097 RW117-1D3-U112 RW317-1D3-U150 RW317-1D3-U150 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U420 5.70 63 .5 7.17 15 .32 22 .6 .5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 350/260 400/300 450/330 500/370 380 V cv / kW 440 V cv / kW 5 / 3.80 75 .32 22 .5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 350/260 400/300 450/330 500/370 - 5 / 3.57 32 .97 90 .7 6 / 4.23 15 .5/5.AC-3 1) 220 V cv / kW 5/3.5 / 5.310 200 .www.5 10 / 7.5 8 .600 560 .2 15/11 20/15 25/18.23 15 .12. analisar os dados de corrente nominal de serviço e corrente de partida.8 7 .5/9.7 6/4. 2) Substituir “¨” pelo código das tensões de comando disponíveis no catálogo específico do produto e substituir “g” pelas seguintes configurações de contatos auxiliares: 20 (K1) e 11 (K2).32 25 .6 .15 11 .420 - DWM1600H-1000-3 DWM1600H-1000-3 - 1000 1000 - CWM500-22-30¨ CWM630-22-30¨ CWM630-22-30¨ CWM800-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U840 RW407-1D3-U840 400 .600 400 .net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico Características g  Proteção contra curto-circuito e seccionamento com possibilidade de bloqueio g  Disparador magnético fixo e calibrado em 12 e 13 vezes a corrente máxima do disjuntor g  Disparador térmico ajustável para proteção contra sobrecargas através do relé de sobrecarga g  Operação automática/remota através do contator g  Elevada vida útil devido a utilização do contator para manobra g  Aplicável a motores que partem a vazio ou cargas de baixa inércia g  Frequência de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .7 6 / 4.310 275 .420 500/370 DWM1600H-700-3 700 CWM400-22-30¨ CWM250-22-30¨ RW317-1D3-U420 275 .150 140 . weg. F22: Fusíveis de comando S0. K2. K3: Contatores FT1: Relé de sobrecarga térmico M: Motor elétrico assincrono trifásico F21. S1: Botões de comando KT1: Relé eletrônico temporizador Y-Δ A1 K3 A1 K1 A2 A2 .net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico Diagramas de Ligação Potência L1 L1 L2 L2 L3 L3 FT1 1 Q1 Q1 3 I> I> I> I> 2 A F21 B F22 95 96 55 S0 II> > 44 1 2 66 AA 3 BB 13 S1 13 K1 4 K3 14 14 15 KT1 1 3 55 22 4 66 1 3 5 22 4 66 11 3 5 2 4 66 K2 K2 K1 K1 K3 K3 1 3 55 2 4 66 18 21 K2 FT1 22 U1 V2 V2 M M 3 3~ V1 V1 W1 W1 A1 U2 U2 KT1 A2 W2 W2 Comando AA F21 F21 B B F22 F22 FT1 FT1 95 96 95 96 S0 S0 S1 S1 11 22 33 K1 K1 44 KT1 KT1 1 3 5 2 4 6 K2 K2 KT1 KT1 28 A1 A1 A2 A2 K3 K3 13 13 14 14 K3 K3 43 43 13 13 K1 K1 14 14 15 15 KT1 KT1 18 18 K3 K3 22 22 A2 A2 25 25 28 28 21 21 21 21 A1 A1 44 44 K1 K1 A1 A1 A2 A2 K2 K2 Guia de Seleção de Partidas 22 22 A1 A1 A2 A2 13 13 K2 K2 14 14 Descrição Q1: Disjuntor-motor magnético K1.www. 12. Consulte catálogo específico do produto.5 .25 2.5 10 / 7.5 .25 .5 MPW16i-3-U010 10 5 / 3.5 5 / 3.5 .5 .420 42 .5 / 5.7 6 / 4.420 DWM800H-420-3 420 CWM250-22-30¨ CWM150-22-30¨ SRW01-UMC5 42 .5 / 9.2 15 / 11 20 / 15 25 / 18. 4) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras.net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga inteligente Características g  Proteção contra curto-circuito através do disjuntor-motor magnético g  Disparador térmico ajustável com classe de disparo de 5 a 45 para proteção contra sobrecargas através do relé inteligente g  Operação automática/remota através do contator g  Elevada vida útil devido a utilização do contator para manobra g  Aplicável a motores que partem a vazio g  Frequência de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .5 / 9.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 350 / 260 400 / 300 450/330 500/370 Contator 2) Referência básica para completar com configuração de contatos auxiliares e tensão de comando K1 = K2 K3 SRW01-UC-˜ 2) + Unidade de medição Unidade de medição Referência Faixa de ajuste (A) CWM9-g-30¨ CWM9-11-30¨ SRW01-UMC2 1.125 12.125 12.125 12.5 10 / 7. regime de serviço contínuo S1.125 12.5 / 5.25 .25 2.125 42 .125 12.420 42 .5 .25 12. fator de serviço igual a 1 em redes de 60 Hz.5 .7 6 / 4.AC-3 1) Disjuntor-motor magnético 220 V cv / kW 380 V cv / kW 440 V cv / kW Referência Corrente nominal (A) - 5 / 3.5 .125 12.125 12.5 7.5 . Motores em outras condições.2 MPW16i-3-U016 16 CWM12-g-30¨ CWM9-11-30¨ SRW01-UMC2 1. Guia de Seleção de Partidas 29 .5 12.5 .125 12.5 - 10 / 7.5 / 5. 3) Referência básica para substituir “˜” por código do protocolo de comunição.5 / 9. tensão de entradas digitais e tensão de alimentação.5 12. Consulte catálogo específico do produto.25 .5 .www.125 12. analisar os dados de corrente nominal de serviço e corrente de partida.12.5 15 / 11 20 / 15 25 / 18.25 2.5 .800 rpm).weg.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 350 / 260 400 / 300 450 / 330 500 / 370 MPW25i-3-U025 MPW25i-3-U032 MPW25i-3-U032 MPW25i-3-U032 MPW65i-3-U040 MPW65i-3-U040 MPW65i-3-U050 MPW65i-3-U050 MPW65i-3-U065 MPW65i-3-U065 DWB160N-80-3MF DWB160N-95-3MF DWB160N-95-3MF DWB250N105-3MF DWB250N150-3MF DWB250N150-3MF DWB250N-185-3MF DWM400H-250-3 DWM400H-250-3 DWM400H-320-3 DWM400H-320-3 25 32 32 32 40 40 50 50 65 65 80 95 95 105 150 150 185 250 250 320 320 CWM18-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM105-g-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM12-11-30¨ CWM12-11-30¨ CWM12-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM32-11-30¨ CWM32-11-30¨ CWM40-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM65-11-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM105-11-30¨ SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 SRW01-UMC3 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC4 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 2.420 42 .5 .12.125 12. 2) Substituir “¨” pelo código das tensões de comando disponíveis no catálogo específico do produto e substituir “ g ” pelas seguintes configurações de contatos auxiliares: 20 (K1) e 11 (K2).25 2.12. código do tipo de proteção.420 DWM800H-500-3 DWM1600H-700-3 DWM1600H-700-3 DWM1600H-700-3 500 700 700 700 CWM300-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM400-22-30¨ CWM250-22-30¨ - DWM1600H-1000-3 DWM1600H-1000-3 - 1000 1000 - CWM500-22-30¨ CWM630-22-30¨ CWM630-22-30¨ CWM800-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC5 SRW01-UMC6 SRW01-UMC6 SRW01-UMC6 SRW01-UMC6 42 42 42 42 42 84 84 84 84 CWM25-g-30¨ - 420 420 420 420 420 840 840 840 840 Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.5 .5 12.7 6 / 4.5 MPW16i-3-U016 16 CWM9-g-30¨ CWM9-11-30¨ SRW01-UMC2 1.5 .125 12.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 350 / 260 400 / 300 450 / 330 500 / 370 - 20 / 15 25 / 18.5 .5 7.2 15 / 11 MPW25i-3-U020 20 CWM12-g-30¨ CWM9-11-30¨ SRW01-UMC2 1.25 .5 7.5 .5 . 250VCC/2 W2 W2 I1 I1 44 K2 I2 I2 K1 K1 13 13 14 14 13 13 K3 K3 F22 F22 S0 S0 33 13 13 14 14 14 14 I3 I3 I4 I4 IC IC A2 A1 A1 SRW01-UC SRW01 . máx.www.net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga inteligente Diagramas de Ligação Potência 11 Q1 > II> 2 2 1 1 L2 L3 L3 3 3 > 110-240 VCA/VCC ou 24 VCA/VCC 5 5 K1 > II> II> 4 3 3 S0 6 11 5 5 K1 K1 2 2 4 4 66 L1 L1 L2 L3 T2 V1 V1 W1 W1 55 2 2 44 66 3 I1 I2 14 4 K2 13 K3 13 14 14 I3 I4 IC O1 O2 A1 A1 A2 A2 K2 C3 K3 O3 F21 U2 U2 Tensão máx.CB SRW01-CB C1C1 K1 K1 O1 O1 A1 A1 K2 K2 A2 A2 O2 O2 A1 A1 A2 A2 C3 C3 K3 K3 O3 O3 C4 C4 O4 O4 A1 A1 A2 A2 F21 F21 Tensão máx. K3: Contator SRW01-UC: Unidade de controle do relé inteligente SRW01-CB: Cabo de interligação UC+UMC SRW01-UMC: Unidade de medição de corrente do relé inteligente M: Motor elétrico assincrono trifásico F21.UC SRW01 .240 VVCA/VCC CA / V CC 110-240 ou 24 24 VVCA/VCC CA / V CC 11 S1 S1 22 C4 A1 V2 V2 M A1 SRW01-UC K1 33 A2 SRW01-CB C1 Comando 6 6 6 33 T3 U1 U1 4 4 4 11 SRW01 . K2. S1: Botões de comando .250 250VCC/240VCA V CC / 240 V CA 30 O4 A2 110 .CB SRW01-CB T1 T1 5 5 K3 K3 2 2 SRW01 .UMC SRW01-UMC 3 3 3 K2 1 S1 2 13 F22 L1 L1 Guia de Seleção de Partidas Descrição Q1: Disjuntor-motor magnético K1.weg. F22: Fusíveis de comando S0. 40 40 .32 32 .5 / 5.5 / 9.5 30 / 22 40 / 30 Contator 2) Referência básica para completar com configuração de contatos auxiliares e tensão de comando K1 = K2 K3 CWM9-g-30¨ CWM9-11-30¨ CWM9-g-30¨ CWM9-11-30¨ 10 .5 7.5 MPW16-3-U016 12.2 15 / 11 20/15 25 / 18.90 70 . fator de serviço igual a 1 em redes de 60 Hz.75 70 .90 70 .2 15 / 11 20 / 15 25 / 18.net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Disjuntor-motor termomagnético + Contatores Características g  Proteção contra curto-circuito e seccionamento com possibilidade de bloqueio g  Disparador magnético fixo e calibrado em 13 vezes a corrente máxima do disjuntor g  Disparador térmico ajustável para proteção contra sobrecargas através do disjuntor g  Operação automática/remota através do contator g  Elevada vida útil devido a utilização do contator para manobra g  Aplicável a motores que partem a vazio ou cargas de baixa inércia g  Frequência de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .5 7.32 25 .50 40 .5 / 9.7 6 / 4.5 / 5.7 6 / 4.800 rpm).16 CWM12-g-30¨ CWM9-11-30¨ 15 / 11 MPW25-3-U020 16 .65 50 .weg.2 12.www.32 25 . 4) Para temporização utilizar os temporizadores eletrônicos modelos: RTW-ET02-U030S ● (códigos de tensão disponíveis no catálogo específico do produto). 3) Limitada pelas características técnicas do disjuntor-motor.100 CWM18-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM12-11-30¨ CWM12-11-30¨ CWM12-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM32-11-30¨ CWM32-11-30¨ CWM40-11-30¨ 7.AC-3 1) Disjuntor-motor termomagnético 220 V cv / kW 380 V cv / kW 440 V cv / kW Referência Corrente nominal (A) - 5 / 3. analisar os dados de corrente nominal de serviço e corrente de partida.20 CWM12-g-30¨ CWM9-11-30¨ 20 / 15 25 / 18.5 / 5.7 6 / 4. Motores em outras condições.90 80 . regime de serviço contínuo S1.5 30 / 22 40 / 30 50 / 37 60 / 45 - Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.5 30 / 22 40 / 30 50 / 37 60 / 45 75 / 55 - MPW25-3-U025 MPW25-3-U032 MPW25-3-U032 MPW25-3-U032 MPW65-3-U040 MPW65-3-U040 MPW65-3-U050 MPW65-3-U050 MPW65-3-U065 MPW65-3-U065 MPW100-3-U075 MPW100-3-U090 MPW100-3-U090 MPW100-3-U090 MPW100-3-U100 20 .5 MPW16-3-U010 6.5 12.16 CWM9-g-30¨ CWM9-11-30¨ MPW16-3-U016 10 .50 50 .5 10 / 7.25 25 . 2) Substituir “¨” pelo código das tensões de comando disponíveis no catálogo específico do produto e substituir “g” pelas seguintes configurações de contatos auxiliares: 20 (K1) e 11 (K2).3 .5 - 10 / 7. Guia de Seleção de Partidas 31 .40 32 .10 5/3.5 5 / 3.5 / 9.5 10 / 7.65 55 . weg.www. K2. S1: Botões de comando KT1: Relé eletrônico temporizador Y-Δ A1 K3 A1 K1 A2 A2 .net Guia de Seleção de Partidas Tipo da partida: Estrela-triângulo Composição: Disjuntor-motor termomagnético + Contatores Diagramas de Ligação Potência L1 L1 L2 L2 11 L3 L3 3 A F21 B F22 5 Q1 Q1 S0 1 2 I> I> I> I> 22 I> I> 44 66 A A 3 13 S1 BB 13 K1 4 K3 14 14 15 KT1 11 3 1 5 3 5 K2 K2 K1 K1 22 4 6 K3 K3 2 4 6 11 3 5 2 4 6 18 21 K2 22 U1 V2 V2 M M 3~ 3 V1 V1 W1 W1 A1 U2 U2 KT1 A2 W2 W2 Comando AA F21 F21 B B F22 F22 S0 S0 S1 S1 11 22 33 K1 K1 44 KT1 KT1 1 3 5 2 4 6 K2 K2 KT1 KT1 32 A1 A1 A2 A2 K3 K3 13 13 14 14 K3 K3 43 43 13 13 K1 K1 14 14 15 15 KT1 KT1 18 18 21 21 K3 K3 22 22 A1 A1 A2 A2 K1 K1 A1 A1 A2 A2 K2 K2 Guia de Seleção de Partidas 44 44 25 25 28 28 13 13 K2 K2 14 14 21 21 22 22 A1 A1 A2 A2 Descrição Q1: Disjuntor-motor termomagnético K1. K3: Contatores M: Motor elétrico assincrono trifásico S0. 150 140 . Consulte catálogo específico do produto.5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 350/260 400/300 450/330 500/370 - FDW-25S FDW-35S FDW-50S FDW-50S FDW-50S FDW-50S FDW-63S FDW-63S FNH000-80U FNH000-80U FNH000-80U FNH00-100U FNH00-125U FNH00-125U FNH00-125U FNH00-160U FNH00-160U FNH1-200U FNH1-200U FNH1-200U FNH1-200U FNH1-224U FNH1-224U FNH1-250U FNH1-250U FNH2-300U FNH2-315U FNH2-355U FNH2-355U FNH2-400U FNH2-400U FNH3-425U FNH3-425U FNH3-500U FNH3-500U FNH3-630U FNH3-630U FNH3-630U 25 35 50 50 50 50 63 63 80 80 80 100 125 125 125 160 160 200 200 200 200 224 224 250 250 300 315 355 355 400 400 425 425 500 500 630 630 630 - - 250/185 300/220 350/260 400/300 450/330 500/370 400/300 450/330 500/370 - Contatores 2) Referência básica para completar com a tensão de comando Relé de sobrecarga K1 K2 K3 Referência CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM40-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM105-g-30¨ CWM105-g-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM500-22-30¨ CWM500-22-30¨ CWM500-22-30¨ CWM500-22-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM95-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM112-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM500-22-30¨ CWM500-22-30¨ CWM630-22-30¨ CWM800-22-30¨ CWM800-22-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM12-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM32-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM32-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM80-11-30¨ CWM80-11-30¨ CWM80-11-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM112-22-30¨ CWM112-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ RW27-1D3-U023 RW27-1D3-U032 RW27-1D3-U032 RW67-1D3-U040 RW67-1D3-U040 RW67-1D3-U050 RW67-1D3-U050 RW67-2D3-U057 RW67-2D3-U057 RW67-2D3-U070 RW67-2D3-U070 RW67-2D3-U080 RW67-2D3-U080 RW117-1D3-U097 RW117-1D3-U112 RW117-1D3-U112 RW317-1D3--U150 RW317-1D3--U150 RW317-1D3--U215 RW317-1D3--U215 RW317-1D3--U215 RW317-1D3--U215 RW317-1D3--U215 RW317-1D3--U215 RW317-1D3--U310 RW317-1D3--U310 RW317-1D3--U310 RW317-1D3--U310 RW317-1D3--U310 RW317-1D3--U310 RW317-1D3--U420 RW317-1D3--U420 RW317-1D3--U420 RW317-1D3--U420 RW317-1D3--U420 RW407-1D3--U600 RW407-1D3--U600 RW407-1D3--U600 RW407-1D3--U600 RW407-1D3--U600 RW407-1D3--U600 RW407-1D3--U840 RW407-1D3--U840 RW407-1D3--U840 - FNH3-630U 630 CWM630-22-30¨ - 800 - CWM630-22-30¨ CWM630-22-30¨ CWM800-22-30¨ - Faixa de ajuste (A) 15 .310 200 .215 140 .310 200 .50 40 .40 25 .600 400 .32 22 .57 57 . fator de serviço igual a 1 em redes de 60 Hz.215 200 .80 63 .420 400 .420 275 .600 400 .600 400 .600 400 .840 - Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.215 140 .420 275 .57 40 .420 275 .112 100 .840 560 .70 63 . Motores em outras condições.310 200 . analisar os dados de corrente nominal de serviço e corrente de partida.70 57 .40 32 .215 140 .310 200 .310 200 .AC-3 1) Fusíveis tipo retardado 4) 220 V cv / kW 380 V cv / kW 440 V cv / kW Referência tamanhos D/NH Corrente nominal (A) 15/11 20/15 25/18. Guia de Seleção de Partidas 33 .97 90 .112 90 .215 140 .840 560 .215 140 .32 25 .5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 15/11 20/15 25/18.23 22 .800 rpm).5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 350/260 - 15/11 20/15 25/18.420 275 . 3) Limitada pelas características técnicas do relé de sobrecarga.600 560 .150 100 . regime de serviço contínuo S1. 4) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras. 2) Substituir “¨” pelo código das tensões de comando disponíveis no catálogo específico do produto e substituir “g” pelas seguintes configurações de contatos auxiliares: 12 (K1) e 20 (K2).weg.www.80 75 .net Guia de Seleção de Partidas Tipo da partida: Compensadora Composição: Fusíveis + Contatores + Relé de sobrecarga térmico Características g  Proteção contra curto-circuito através dos fusíveis tipo gL/gG g  Disparador térmico ajustável para proteção contra sobrecargas através do relé de sobrecarga g  Operação automática/remota através do contator g  Elevada vida útil devido a utilização do contator para manobra g  Aplicável a motores que partem com carga g  Frequência de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .50 32 .310 275 . K3: Contatores FT1: Relé de sobrecarga térmico T1: Autotransformador com TAP de 65% e 80% M: Motor elétrico assincrono trifásico F21. F6: Fusíveis de potência K1. S1: Botões de comando KT1: Relé eletrônico temporizador retardo na energização de 3.net Guia de Seleção de Partidas Tipo da partida: Compensadora Composição: Fusíveis + Contatores + Relé de sobrecarga térmico Diagramas de Ligação Potência L1 L2 F1 F1 F2 F2 L3 L3 F3 F3 AA BB A F21 B F22 FT1 95 96 1 S0 2 11 33 5 11 K2 K2 33 55 K1 K1 2 44 22 66 44 66 3 S1 4 13 15 K3 18 80% 80% 80% 80% 100% 100% 100% 100% 80% 80% 100% 100% KT1 11 T1 T1 65% 65% 65% 65% 65% 65% 44 K1 32 66 0%T 0%T 0%S 0%S 31 55 FT1 FT1 22 0%R 0%R 33 K3 2 1 34 5 6 21 3 4 65 U1 U1 V1 W1 W1 K3 K3 M M 33~ Comando AA F21 F21 B B F22 F22 95 95 FT1 FT1 96 96 1 1 S0 S0 2 33 13 13 S1 S1 13 13 K1 K1 K2 K2 14 14 44 16 16 18 K1 K1 K3 K3 14 14 21 21 13 13 15 15 KT1 KT1 43 43 K2 K2 22 22 14 14 21 21 K3 44 44 22 22 31 31 K1 32 32 K3 K3 34 A1 A1 A2 A2 Guia de Seleção de Partidas K2 K2 A1 A1 A2 A2 KT1 KT1 A1 A1 A2 A2 K1 A1 A1 A2 A2 16 Descrição F1. F5.30s A1 A2 14 . F4. F2. K2. F22: Fusíveis de comando S0...www. F3.weg. 600 400 .50 40 .net Guia de Seleção de Partidas Tipo da partida: Compensadora Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico Características g  Proteção contra curto-circuito e seccionamento com possibilidade de bloqueio mecânico por circuito individual de motores g  Disparador térmico ajustável para proteção contra sobrecargas através do relé de sobrecarga g  Disparador magnético fixo e calibrado em 13 vezes a máxima corrente do disjuntor-motor g Operação automática/remota através do contator g  Elevada vida útil devido a utilização do contator para manobra g Aplicável a motores que partem a vazio g Frequência de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .23 22 .40 32 .840 560 .40 25 .5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 350/260 400/300 450/330 500/370 - Disjuntor-motor magnético Referência MPW25i-3-U020 MPW25i-3-U025 MPW25i-3-U032 MPW65i-3-U032 MPW65i-3-U040 MPW65i-3-U040 MPW65i-3-U050 MPW65i-3-U065 MPW65i-3-U065 MPW65i-3-U065 DWB160N80-3MF DWB160N95-3MF DWB250N105-3MF DWB250N150-3MF DWB250N150-3MF DWB250N150-3MF DWB250N150-3MF DWM400H-185-3 DWM400H-185-3 DWM400H-250-3 DWM400H-250-3 DWM400H-250-3 DWM400H-320-3 DWM400H-320-3 DWM800H-420-3 DWM800H-420-3 DWM800H-420-3 DWM800H-420-3 DWM800H-420-3 DWM800H-500-3 DWM800H-500-3 DWM1600H-700-3 DWM1600H-700-3 DWM1600H-700-3 DWM1600H-1000-3 DWM1600H-1000-3 - Contatores 2) Referência Relé de sobrecarga Corrente nominal In (A) K1 K2 K3 20 25 32 32 40 40 50 65 65 65 80 95 105 150 150 150 150 185 185 250 250 250 320 320 420 420 420 420 420 500 500 700 700 700 700 1000 1000 - CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM105-g-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM500-22-30¨ CWM500-22-30¨ CWM500-22-30¨ CWM500-22-30¨ CWM630-22-30¨ CWM630-22-30¨ CWM630-22-30¨ CWM800-22-30¨ - CWM18-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM95-g-30¨ CWM112-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM300-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM400-22-30¨ CWM500-22-30¨ CWM630-22-30¨ CWM630-22-30¨ CWM800-22-30¨ CWM800-22-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM12-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM25-11-30¨ CWM25-11-30¨ CWM32-11-30¨ CWM32-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM40-11-30¨ CWM50-11-30¨ CWM50-11-30¨ CWM65-11-30¨ CWM65-11-30¨ CWM80-11-30¨ CWM80-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM95-11-30¨ CWM112-22-30¨ CWM112-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM150-22-30¨ CWM180-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM250-22-30¨ CWM300-22-30¨ Referência Faixa de ajuste (A) RW27-1D3-U023 RW27-1D3-U032 RW27-1D3-U032 RW67-1D3-U040 RW67-1D3-U040 RW67-1D3-U050 RW67-2D3-U057 RW67-2D3-U057 RW67-2D3-U070 RW67-2D3-U070 RW67-2D3-U080 RW117-1D3-U097 RW117-1D3-U112 RW317-1D3-U150 RW317-1D3-U215 RW317-1D3-U150 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U215 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U310 RW317-1D3-U420 RW317-1D3-U420 RW317-1D3-U420 RW317-1D3-U420 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U600 RW407-1D3-U840 RW407-1D3-U840 RW407-1D3-U840 - 15 .420 275 .215 140 .150 140 .215 140 .www.weg. Motores em outras condições. regime de serviço contínuo S1.80 75 .310 200 .420 275 .32 25 .5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 15/11 20/15 25/18.310 275 .840 - Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.310 200 .5 30/22 40/30 50/37 60/45 75/55 100/75 125/90 150/110 175/132 200/150 250/185 300/220 350/260 - 250/185 400/300 300/220 350/260 400/300 450/330 500/370 450/330 500/370 - 15/11 20/15 25/18.32 22 . fator de serviço igual a 1 em redes de 60 Hz.420 400 .600 560 . analisar os dados de corrente nominal de serviço e corrente de partida.310 200 .70 57 .840 560 .70 63 .420 275 .215 100 .600 400 .600 400 . Guia de Seleção de Partidas 35 .57 40 .600 400 .800 rpm).215 140 . 2) Substituir “¨” pelo código das tensões de comando disponíveis no catálogo específico do produto e substituir “g” pelas seguintes configurações de contatos auxiliares: 12 (K1) e 20 (K2).57 57 .97 90 .150 140 .112 100 .AC-3 1) 220 V cv / kW 380 V cv / kW 440 V cv / kW 15/11 20/15 25/18.215 200 . 3) L  imitada pelas características técnicas do relé de sobrecarga. K2.30s A2 14 .weg. S1: Botões de comando KT1: Relé eletrônico temporizador retardo na energização de 3.. K3: Contatores FT1: Relé de sobrecarga térmico T1: Autotransformador com TAP de 65% e 80% M: Motor elétrico assincrono trifásico F21. F22: Fusíveis de comando S0.www..net Guia de Seleção de Partidas Tipo da partida: Compensadora Composição: Disjuntor-motor magnético + Contatores + Relé de sobrecarga térmico Diagramas de Ligação Potência L1 L1 L2 L2 11 3 L3 L3 5 Q1 Q1 I> I> 22 I> I> 44 II> > 6 AA A F21 B F22 FT1 95 96 1 S0 2 BB 3 11 3 55 22 44 6 11 33 55 22 44 66 S1 K1 K1 K2 K2 4 13 15 K3 1 1 33 5 2 44 66 31 K1 FT1 FT1 65% 32 A1 K3 22 44 66 1 33 55 U1 V1 V1 W1 W1 K3 K3 M M 33~ Comando A F21 F21 BB F22 F22 95 95 FT1 FT1 96 96 1 1 S0 2 2 33 13 13 13 13 S1 S1 K2 K2 K1 K1 K3 K3 16 16 14 14 21 21 13 13 15 15 18 18 K1 K1 14 14 4 KT1 KT1 K3 K3 44 44 22 22 14 14 21 21 43 43 K2 K2 22 22 31 31 K1 32 32 K3 36 16 80% 80% 80% 80% 100% 100% 80% 80% 18 0%T 0%T 65% 0%S 0%S 65% 65% 0%R 0%R T1 T1 100% 100% 100% 100% KT1 A1 A1 A2 A2 Guia de Seleção de Partidas K2 K2 A1 A1 A2 A2 KT1 KT1 A1 A1 A2 A2 K1 K1 A1 A1 A2 A2 Descrição K1. 3) Limitada pelas características técnicas do disjuntor-motor.www.5 30/22 50/37 60/45 60/45 75/55 40/30 - Disjuntor-motor magnético Corrente nominal In (A) MPW25-3-U020 16 .5 30/22 30/22 40/30 20/15 40/30 50/37 25/18. regime de serviço contínuo S1.net Guia de Seleção de Partidas Tipo da partida: Compensadora Composição: Disjuntor-motor termomagnético + Contatores Características g  Proteção contra curto-circuito e seccionamento com possibilidade de bloqueio mecânico por circuito individual de motores g  Disparador térmico ajustável para proteção contra sobrecargas incorporado no disjuntor-motor g  Disparador magnético fixo e calibrado em 13 vezes a máxima corrente da faixa de ajuste do disjuntor-motor g  Operação automática/remota através do contator g  Elevada vida útil devido a utilização do contator para manobra g Aplicável a motores que partem a vazio g Frequência de manobras: 15 manobras/hora 3) Tabela orientativa de motores trifásicos .100 CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM80-g-30¨ CWM95-g-30¨ CWM105-g-30¨ CWM32-g-30¨ CWM40-g-30¨ CWM50-g-30¨ CWM50-g-30¨ CWM65-g-30¨ CWM65-g-30¨ CWM12-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM18-11-30¨ CWM25-11-30¨ CWM25-11-30¨ Referência K3 CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ CWM9-11-30¨ Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1. Guia de Seleção de Partidas 37 . Motores em outras condições.65 55 .40 CWM40-g-30¨ CWM25-g-30¨ CWM9-11-30¨ MPW65-3-U050 MPW65-3-U065 MPW65-3-U065 MPW100-3-U075 MPW100-3-U090 MPW100-3-U100 40 .AC-3 1) 220 V 380 V 440 V cv / kW cv / kW cv / kW 15/11 15/11 20/15 20/15 25/18.65 50 .32 MPW25-3-U032 25 . 2) Substituir “¨” pelo código das tensões de comando disponíveis no catálogo específico do produto e substituir “g” pelas seguintes configurações de contatos auxiliares: 12 (K1) e 20 (K2).75 70 .32 K1 CWM25-g-30¨ CWM25-g-30¨ CWM32-g-30¨ CWM32-g-30¨ Contatores 2) Referências K2 CWM18-g-30¨ CWM18-g-30¨ CWM18-g-30¨ CWM25-g-30¨ MPW65-3-U040 32 .5 15/11 25/18.25 MPW25-3-U032 25 .90 80 .weg. analisar os dados de corrente nominal de serviço e corrente de partida.20 MPW25-3-U025 20 .800 rpm).50 50 . fator de serviço igual a 1 em redes de 60 Hz. weg.30s A2 14 .. K3: Contatores T1: Autotransformador com TAP de 65% e 80% M: Motor elétrico assincrono trifásico F21. K2.net Guia de Seleção de Partidas Tipo da partida: Compensadora Composição: Disjuntor-motor termomagnético + Contatores Diagramas de Ligação Potência L1 L2 L3 L3 11 33 5 Q1 Q1 II> > II> > II> > 22 4 6 AA A F21 B F22 1 S0 2 B 3 1 3 55 22 44 6 K2 K2 11 33 55 2 44 6 S1 K1 K1 4 13 15 K3 KT1 0%R 0%R 16 80% 80% 100% 80% 80% 65% 65% 0%S 0%S 65% 65% T1 T1 31 65% 65% K1 32 A1 0%T 0%T 80% 80% 100% 100% 18 K3 22 44 6 11 33 55 U1 U1 W1 W1 V1 V1 K3 K3 M M 33~ Comando A F21 F21 B F22 F22 1 1 S0 S0 2 2 33 13 13 13 13 S1 S1 K1 K1 K2 K2 14 14 4 21 21 13 13 15 15 KT1 KT1 18 18 K1 K1 K3 K3 16 16 14 14 K3 K3 22 22 44 44 22 22 14 14 21 21 43 43 K2 K2 31 31 K1 K1 32 32 K3 K3 38 A1 A1 A2 A2 Guia de Seleção de Partidas K2 K2 A1 A1 A2 A2 KT1 KT1 A1 A1 A2 A2 K1 K1 A1 A1 A2 A2 Descrição Q1: Disjuntor termomagnético K1. S1: Botões de comando KT1: Relé eletrônico temporizador retardo na energização de 3.www.. F22: Fusíveis de comando S0. 2) Tensão de comando 110-230 V CA (modelos de 17 A a 200 A).net Guia de Seleção de Partidas Tipo da partida: Suave (Soft-starter) Composição: Fusíveis ultrarrápidos + Soft-starter Características g Proteção contra curto-circuito através dos fusíveis tipo aR g  Proteções integradas a soft-starter: sobrecarga.AC-3 1) 380 V 440 V cv / kW cv / kW 10 / 7..5 20 / 15 20 / 15 12. regime de serviço contínuo S1.5 12.5 / 9.2 7.5 20 / 15 40 / 30 25 / 18. Motores em outras condições.weg.5 / 9.5 12.2 25 / 18.AC-3 1) 380 V 440 V cv / kW cv / kW 10 / 7.5 / 9.www.5 30 / 22 40 / 30 50 / 37 50 / 37 60 / 45 30 / 22 75 / 55 20 / 15 25 / 18.5 15 / 11 15 / 11 10 / 7.5 125 / 90 150 / 110 - g 200 / 150 250 / 185 300 / 220 250 / 185 300 / 225 350 / 260 Fusíveis ultrarrápidos 5) Corrente nominal (A) FNH1-63-K-A 63 Referência Soft-starters Corrente nominal (A) SSW080017T5SZ 17 Referência FNH00-80-K-A 80 SSW080024T5SZ 24 FNH00-100-K-A 100 SSW080030T5SZ 30 FNH00-160-K-A 160 SSW080045T5SZ 45 FNH1-200-K-A 200 SSW080061T5SZ 61 FNH00-250-K-A 250 SSW080085T5SZ 85 FNH2-400-K-A 400 SSW080130T5SZ 130 FNH2-500-K-A 500 SSW080171T5SZ 171 FNH2-630-K-A 630 SSW080200T5SZ 200 FNH3-500-K-A 500 SSW080255T5SgZ 255 FNH3-710-K-A FNH3-710-K-A FNH3-500-K-A 710 710 500 SSW080312T5SgZ SSW080365T5SgZ SSW080412T5SgZ 312 365 412 H1: Comando 110-130 V CA ou H2: Comando em 208-240 V CA Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1.2 12. 4) Limitada pelas características técnicas da soft-starter: 10 partidas/h (1 a cada 6 minutos) de 10 A a 820 A e 5 partidas/h (1 a cada 12 minutos) de 950 A a 1400 A.5 / 9. Consulte catálogo específico do produto.5 / 5.800 rpm)..5 15 / 11 15 / 11 220 V cv / kW 6 / 4.5 30 / 22 15 / 11 30 / 22 20 / 15 40 / 30 50 / 37 25 / 18.2 12. 6)Para outros tipos de partida consulte manual específico do produto ou utilize o software SDW no site WEG. sequência e falta de fase g Aplicável a motores que partem a vazio e com baixa inércia 6) g Frequência de manobras: 5. analisar os dados de corrente nominal de serviço e corrente de partida.5 10 / 7.5 12.5 30 / 22 40 / 30 50 / 37 Fusíveis ultrarrápidos 5) Corrente nominal (A) FNH1-63-K-A 63 Referência Soft-starters Corrente nominal (A) SSW070017T5SZ 17 Referência FNH00-80-K-A 80 SSW070024T5SZ 24 FNH00-100-K-A 100 SSW070030T5SZ 30 FNH00-125-K-A 125 SSW070045T5SZ 45 FNH00-125-K-A 125 SSW070045T5SZ 45 FNH00-160-K-A 160 SSW070061T5SZ 61 60 / 45 FNH00-250-K-A 250 SSW070085T5SZ 85 75 / 55 100 / 75 FNH1-400-K-A 400 SSW070130T5SZ 130 125 / 90 FNH2-500-K-A 500 SSW070171T5SZ 171 150 / 110 175 / 132 200 / 150 250 / 185 300 / 220 FNH2-630-K-A 630 SSW070200T5SZ 200 FNH3-500-K-A 500 SSW070255T5SgZ 255 125 / 90 150 / 110 100 / 75 125 / 90 150 / 110 175 / 132 200 / 150 250 / 185 FNH3-710-K-A FNH3-710-K-A 710 SSW070312T5SgZ SSW070365T5SgZ 312 365 150 / 110 300 / 220 350 / 260 FNH3-500-K-A 500 SSW070412T5SgZ 412 60 / 45 75 / 55 100 / 75 SSW08 Ligação padrão Tabela orientativa de motores trifásicos .10 manobras/hora 4) SSW07 Ligação padrão Tabela orientativa de motores trifásicos .2 7.5 / 5. fator de serviço igual a 1. 5) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras. Guia de Seleção de Partidas 39 .5 50 / 37 60 / 45 30 / 22 60 / 45 40 / 30 75 / 55 100 / 75 50 / 37 100 / 75 60 / 45 125 / 90 125 / 90 75 / 55 150 / 110 150 / 110 200 / 150 100 / 75 175 / 132 220 V cv / kW 6 / 4.2 15 / 11 - 20 / 15 25 / 18.5 / 9.5 / 9. 3) Potências válidas para temperatura ambiente 40 ºC. weg.www. F21: Fusíveis de comando S0: Botão de comando com retenção (aciona/desaciona) A1. F2.net Guia de Seleção de Partidas Tipo da partida: Suave (Soft-starter) Composição: Fusíveis ultrarrápidos + Soft-starter Diagramas de Ligação Potência e Comando L1 L1 L2 L2 L1 L1 L3 L3 L2 L2 L1 L3 L3 L2 L2 F1 F1 F1 F2 F2 F3 F3 OU OU OU OU Q1 Q1 L3 L3 F2 F3 11 33 55 22 4 6 K1 K1 F12 F12 F11 F11 T1T1 F21 F21 R/1L1 S/3L2 S/3L2 T/5L3 R/1L1 T/5L3 A2 A2 A1 A1 DI1 DI1 S0 S0 1 2 SSW SSW U/2T1 V/4T2 V/4T2 W/6T3 W/6T3 U/2T1 RL1 RL1 M 33~ 40 Guia de Seleção de Partidas K1 K1 Descrição F1. F12. A2: Alimentação da CPU da soft-starter K1: Contator de isolação (opcional) Q1: Chave seccionadora (opcional) T1: Transformador de comando (opcional) SSW: Soft-starter . F3: Fusíveis de potência F11. .2 6 / 4. 3) P  otências válidas para temperatura ambiente 40 ºC.weg.. regime de serviço contínuo S1. 6)Para outros tipos de partida consulte manual específico do produto ou utilize o software SDW no site WEG. 2) Tensão de comando 110-230 V CA (modelos de 17 A a 200 A).5 12. Consulte catálogo específico do produto. analisar os dados de corrente nominal de serviço e corrente de partida.5 / 11 15 / 11 7.5 / 9. 5) Limitada pelas características técnicas da soft-starter: 10 partidas/h (1 a cada 6 minutos) de 10 A a 820 A e 5 partidas/h (1 a cada 12 minutos) de 950 A a 1400 A.5 / 5.www.7 10 / 7.net Guia de Seleção de Partidas Tipo da partida: Suave (Soft-starter) Composição: Fusíveis ultrarrápidos + Soft-starter Características g Proteção contra curto-circuito através dos fusíveis tipo aR g Proteções integradas a soft-starter: sobrecarga.5 5 / 3.2 6 / 4. Guia de Seleção de Partidas 41 .5 4/3 7.5 / 5.5 7.5 10 / 7.5 15 / 11 10 / 7.AC-3 1) 220 V 380 V 440 V cv / kW cv / kW cv / kW Ligação padrão 3 / 2. fator de serviço igual a 1.5 15 / 11 30 / 22 30 / 22 20 / 15 40 / 30 40 / 30 25 / 18. Motores em outras condições.5 / 5.5 12.5 50 / 37 50 / 37 30 / 22 60 / 45 60 / 45 75 / 55 40 / 30 75 / 55 50 / 37 100 / 75 100 / 75 60 / 45 125 / 90 125 / 90 75 / 55 150 / 110 150 / 110 175 / 132 100 / 75 175 / 132 200 / 150 125 / 90 200 / 150 250 / 185 150 / 110 250 / 185 300 / 225 150 / 110 300 / 220 350 / 260 175 / 132 350 / 260 400 / 300 200 / 150 400 / 300 450 / 330 250 / 185 450 / 330 500 / 370 250 / 185 500 / 370 550 / 410 300 / 220 550 / 410 700 / 525 350 / 260 400 / 300 750 / 550 800 / 600 450 / 330 800 / 600 900 / 670 500 / 410 1000 / 750 1200 / 900 Ligação dentro do delta do motor 30 / 22 50 / 37 60 / 45 60 / 45 40 / 30 75 / 55 75 / 55 50 / 37 100 / 75 100 / 75 60 / 45 125 / 90 125 / 90 150 / 110 75 / 55 150 / 110 175 / 132 100 / 75 175 / 132 200 / 150 125 / 90 200 / 150 250 / 185 150 / 110 250 / 185 300 / 220 175 / 132 300 / 225 350 / 260 350 / 260 400 / 300 200 / 150 400 / 300 450 / 330 250 / 185 450 / 330 500 / 370 250 / 185 500 / 370 600 / 450 300 / 220 600 / 450 700 / 525 350 / 260 400 / 300 750 / 550 850 / 630 450 / 330 500 / 370 600 / 450 700 / 520 800 / 600 1050 / 775 g 850 / 630 1000 / 750 1200 / 900 1400 / 1030 1750 / 1290 950 / 700 1200 / 900 1400 / 1030 1600 / 1175 2000 / 1475 Fusíveis ultrarrápidos 4) Corrente nominal (A) Referência Referência Soft-starters 2) Corrente nominal (A) FNH00-40-K-A 40 SSW060010T2257PSZ 10 FNH00-40-K-A 40 SSW060016T2257PSZ 16 FNH00-80-K-A 80 SSW060023T2257PSZ 23 FNH00-125-K-A 125 SSW060030T2257PSZ 30 FNH00-125-K-A 125 SSW060045T2257PSZ 45 FNH00-160-K-A 160 SSW060060T2257PSZ 60 FNH00-250-K-A 250 SSW060085T2257PSZ 85 FNH1-400-K-A 400 SSW060130T2257PSZ 130 FNH2-630-K-A 630 SSW060170T2257PSZ 170 FNH2-630-K-A 630 SSW060205T2257PSZ 205 FNH3-710-K-A 710 SSW060255T2257PSZ 255 FNH3-710-K-A FNH3-710-K-A FNH3-1000-K-A 710 710 1000 SSW060312T2257PSZ SSW060365T2257PSZ SSW060412T2257PSZ 312 365 412 2 x FNH2-630-K-A 630 SSW060480T2257PSZ 480 2 x FNH2-710-K-A 710 SSW060604T2257PSZ 604 2 x FNH3-800-K-A 800 SSW060670T2257PSZ 670 2 x FNH3-900-K-A 900 SSW060820T2257PSZ 820 2 x FNH3-1000-K-A 3 x FNH2-710-K-A 3 x FNH3-900-K-A 1000 710 900 SSW060950T2257PSgZ 3) SSW061100T2257PSH2Z 3) SSW061400T2257PSH2Z 3) 950 1100 1400 FNH1-200-K-A 200 SSW060045T2257PSZ 45 FNH1-200-K-A 200 SSW060060T2257PSZ 60 FNH2-400-K-A 400 SSW060085T2257PSZ 85 FNH3-500-K-A 500 SSW060130T2257PSZ 130 FNH3-710-K-A 710 SSW060170T2257PSZ 170 FNH3-710-K-A 710 SSW060205T2257PSZ 205 2 x FNH3-400-K-A 400 SSW060255T2257PSZ 255 3 x FNH2-310-K-A 315 SSW060312T2257PSZ 312 2 x FNH3-500-K-A 2 x FNH3-710-K-A 500 710 SSW060365T2257PSZ SSW060412T2257PSZ 365 412 2 x FNH3-1000-K-A 1000 SSW060480T2257PSZ 480 2 x FNH3-1000-K-A 1000 SSW060604T2257PSZ 604 3 x FNH3-800-K-A 3 x FNH3-800-K-A 3 x FNH3-900-K-A 3 x FNH3-1000-K-A 4 x FNH3-1000-K-A 800 800 900 1000 1000 SSW060670T2257PSZ SSW060820T2257PSZ SSW060950T2257PSgZ 3) SSW061100T2257PSH2Z 3) SSW061400T2257PSH2Z 3) 670 820 950 1100 1400 H1: Comando 110-130 V CA ou H2: Comando em 208-240 V CA Notas: 1) D  imensionamentos válidos para motores WEG W22 de IV polos (1.2 25 / 18.800 rpm).5 20 / 15 20 / 15 12. 4) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras.5 25 / 18.5 / 9.10 manobras/hora 5) g SSW06 Tabela orientativa de motores trifásicos . sequência e falta de fase g Bypass interno na soft-starter até 820 A  plicável a motores que partem a vazio e com A baixa inércia 6) g  Frequência de manobras: 5. A2: Alimentação da CPU da soft-starter K1: Contator de isolação (opcional) Q1: Chave seccionadora sob carga (opcional) T1: Transformador de comando (opcional) SSW: Soft-starter S0 .www. F12. F3: Fusíveis de potência F11. F21: Fusíveis de comando S0: Botão de comando com retenção (aciona/desaciona) A1.net L1 L2 L1 L3 L2 L3 L1 L2 Guia de Seleção de Partidas F1 F2 F3 OU F1 OU Q1 Tipo da partida: Suave (Soft-starter) Composição: Fusíveis ultrarrápidos + Soft-starter L3 F2 F3 1 3 5 2 4 6 K1 Diagramas de Ligação Ligação padrão Modos de proteção (ligação padrão e ligação dentro do delta motor) L1 L1 L2 L2 L2 L2 L1 L3 L3 L3 L3 F12 F12 L1 L1 F12 F1 F1 F11 F11 F2 F2 F3 F3 OU OU Q1 Q1 T1 T1 F1 F1 OU OU F11 R/1L1 22 L3 3 5 2 4 6 44 66 T/5L3 A2 A1 S0 1 2 F12 F11 K1 T1 RL1 U/2T1 F3 1 22 V/4T2 W/6T3 F21 M 33~ OU 5 SSW T1 L3 F2 33 F21 F1 11 K1 K1 RL1 RL1 L2 F3 DI1 F11 L1 S/3L2 F12 SSW SSW L2 F2 F2 F21 F21 F21 11 S0 S0 A1 A1 DI1 DI1 U/2T1 V/4T2 W/6T3 U/2T1 V/4T2 W/6T3 L3 L3 K1 K1 T1 A2 A2 R/1L1 S/3L2 S/3L2 T/5L3 R/1L1 T/5L3 L2 L2 M 3~ K1 R/1L1 S/3L2 T/5L3 A2 A1 S0 1 R/1L1 2 S/3L2 T/5L3 DI1 SSW Ligação dentro do delta do motor K1 RL1 RL1 V/4T2 W/6T3 U/2T1 V/4T2 W/6T3 F12 F12 M 3~ F11 F11 M 3~ T1 T1 F21 F21 R/1L1 S/3L2 S/3L2 T/5L3 R/1L1 T/5L3 A2 A2 A1 A1 S0 S0 11 22 DI1 DI1 SSW SSW U/2T1 V/4T2 V/4T2 W/6T3 W/6T3 U/2T1 RL1 RL1 M M 33~ 42 A1 DI1 SSW U/2T1 A2 Guia de Seleção de Partidas K1 Descrição F1. F2.weg. 75 / 0. regime de serviço contínuo S1.5 5 / 3. Consulte catálogo específico do produto. 2) Limitada pelas características técnicas da soft-starter (1 a cada 15 minutos).5 7. A2: Alimentação da CPU da soft-starter K1: Contator de isolação (opcional) Q1: Chave seccionadora (opcional) T1: Transformador de comando (opcional) SSW: Soft-starter Guia de Seleção de Partidas 43 . F12.net Guia de Seleção de Partidas Tipo da partida: Suave (Soft-starter) Composição: Fusíveis ultrarrápidos + Soft-starter Características g Proteção contra curto-circuito através dos fusíveis tipo aR g Proteções integradas a soft-starter: sobrecarga.5 12. sequência e falta de fase g Aplicável a motores que partem a vazio e com baixa inércia 4) g Frequência de manobras: 4 manobras/hora 2) Tabela orientativa de motores trifásicos .5 15 / 11 15 / 11 10 / 7.AC-3 1) 220 V 380 V 440 V cv / kW cv / kW cv / kW 0.5 3 / 2.weg. 5) Tensão de comando 90-250 V CA. fator de serviço igual a 1 em redes de 60 Hz. analisar os dados de corrente nominal de serviço e corrente de partida.2 6 / 4. F2.5 / 5.7 10 / 7.5 1.5 / 1.2 7. 3) Para instalação dos fusíveis os mesmos deverão ser montados em base fusíveis ou seccionadoras. F3: Fusíveis de potência F11.5 / 9.5 / 5. F21: Fusíveis de comando S0: Botão de comando com retenção (aciona/desaciona) A1.1 2 / 1.www.5 20 / 15 20 / 15 15 / 11 30 / 22 30 / 22 20 / 15 40 / 30 40 / 30 30 / 22 60 / 45 60 / 45 Fusíveis ultrarrápidos 3) Corrente nominal (A) FNH00-40-K-A 40 FNH00-40-K-A 40 FNH00-40-K-A 40 FNH00-100-K-A 100 FNH00-100-K-A 100 FNH00-125-K-A 125 FNH00-160-K-A 160 FNH00-250-K-A 250 Referência Soft-starters 5) Corrente nominal (A) SSW050003T2246PPZ 3 SSW050010T2246PPZ 10 SSW050016T2246PPZ 16 SSW050023T2246PPZ 23 SSW050030T2246PPZ 30 SSW050045T2246PPZ 45 SSW050060T2246PPZ 60 SSW050085T2246PPZ 85 Referência Notas: 1) Dimensionamentos válidos para motores WEG W22 de IV polos (1. 4) Para outros tipos de partida consulte manual específico do produto ou utilize o software SDW no site WEG.800 rpm). Diagramas de Ligação L1 L1 L2 L2 L1 L1 L3 L3 L2 L2 L3 L3 L1 L2 L2 F1 F1 F1 F1 F2 F2 F3 F3 OU OU OU OU Q1 Q1 L3 L3 F2 F2 F3 F3 11 33 5 2 4 6 K1 K1 F12 F12 F11 F11 T1T1 F21 F21 R/1L1 S/3L2 S/3L2 T/5L3 R/1L1 T/5L3 A2 A2 A1 A1 S0 S0 1 22 DI1 DI1 SSW SSW U/2T1 V/4T2 V/4T2 W/6T3 W/6T3 U/2T1 M 33~ RL1 RL1 K1 K1 Descrição F1. Motores em outras condições. net www.net www.SC .Brasil Telefone: (47) 3276-4000 [email protected] Automação Jaraguá do Sul .Cód: 50037327 | Rev: 01 | Data (m/a): 08/2013 Sujeito a alterações sem aviso prévio. Grupo WEG .com/wegvideos @weg_wr .weg. As informações contidas são valores de referência.youtube.
Copyright © 2024 DOKUMEN.SITE Inc.