Vogel PumpenVogel Pumpen Vogel - Multistage Pumps Design P, PVa, MP 300 Sizes DN 80 - DN 300 1 p. Pumpenfabrik ERNST VOGEL has developed and manufactured multistage pumps since 1910. Our application and manufacturing expertise provide you with the BEST SOLUTION to meet your pumping needs. speed up to 3.m) Multistage pumps of series MP with smaller capacities and max. Handled liquids: Pure as well as slightly contaminated media such as: hot and cold water condensate oil suspensions acids as well as their watery solutions caustic solutions brine Sizes: DN 80 up to DN 300 (from 3“ to 12“) discharge Application: Max. speed up to 1750 min-1 (1750 r. casing pressure: 45 bar (650 psig) For more detailed information about operation limits with regard to material of construction and operating conditions please refer to data sheets or actual quotations.Vogel Pumpen VOGEL MULTISTAGE PUMPS Performance range: Capacities up to 1800 m3/h (8800 USgpm) Head up to 300 m (1000 feet) Max.B.1. 2 .600 min-1). refer to brochure 2200. temperature: 140oC (280oF) water supply booster systems irrigation fire fighting cooling circuits boiler feed condesate district heating osmosis and ultra filtration spray water systems cleaning systems mining Max. minimum vibrations.1 MP 300. Axial thrust minimized by balance holes for minimum bearing loads and a maximum bearing liftetime. All design versions acc. Balanced radial forces. Size MP 300.1. PVa 204 P 253 P 254 MP 300. Size 84-104 P: one piece design for diffusor and casing. 3 .Vogel Pumpen VOGEL MULTISTAGE PUMPS VOGEL Multistage pumps utilize a modular design concept which maximizes component interchangeability. closed radial type impellers designed for casing wear ring on bolth sides.1 and MP 300. Size 124 PA-254 P and MP 300. PVa 154 P. minimum shaft deflection. Size Discharge branch DNd [mm] 80 100 125 150 200 250 250 300 300 Suction branch DNs [mm] 100 125 150 200 250 300 300 400 400 Capacity at BEP Q [m3/h] 5 0 Hz Capacity at BEP Q [m3/h] 6 0 Hz 140 200 300 500 790 900 1100 1) 1) P.2: two piece design for diffusor and casing. PVa 104 PA. ISO 9001 certification guarantees high quality standards and reliability of our products.2 1) upon request 120 170 250 420 660 800 980 1200 1400 Hydraulics: Sizes 84-254. PVa 84 P. multiple design configurations can be engineered to meet customer requirements without compromise to repair part inventories. PVa 124 PA. As such. Heavy duty design for long term operation in industrial applications. 300. Modular system: The entire performance range is covered by 7 mechanical sizes that hold 9 different hydraulics. to ISO 5199 / EN 25199.2 thrust balanced by a balancing drum. p.m.1.B Performance range . MP40.1.50 Hz 1450 r.Vogel Pumpen VOGEL MULTISTAGE PUMPS Performance range .60 Hz 1750 r. in MP-brochure Liste 2200. in MP-brochure Liste 2200.-MP125.p.-MP125. MP40.B 4 .m. Vogel Pumpen VOGEL MULTISTAGE PUMPS Design versions: Type P. Standard IEC motors. Sectional drawing page 8 5 . Type PT Vertical wet pit configuration length: max. 10 m . with suction branch left and discharge branch radially upwards. Type PVa: Vertical design with separate thrust bearing and flexible coupling between motor and pump. PA.p. up to 315 kW. MP 300: Horizontal shaft with bearings at both ends. Counter clockwise rotation and other flange orientations are available as an option.1450 / 1750 r. oil lubrication.m. drive-end at discharge side (standard). rotation clockwise. Inducer design available. Drive side discharge. Maintenance friendly design.Vogel Pumpen VOGEL MULTISTAGE PUMPS TYPE P: ● ● ● Horizontal configuration with outer bearings on both sides. Drive side thrust bearing. two angular contact ball bearings. discharge radially upwards. Suction side roller bearing as floating bearing. via flexible coupling. Driven by electric motors. Bearings and shaft seal are maintainable without pump disassembly. Thermal expansion of the pump rotor will be balanced internally without affecting the shaft alignment. combustion engines or steam turbines. Branches can be adjusted to meet customer requirements in 90 o increments. Oil lubrication with large capacity oil sump. clockwise rotation (drive side suction and counter clockwise rotation available). Branch directions: suction left viewed from drive end. Shaft sealing arrangements (mechancial seal or gland packing) see pages 9 and 10. ● ● ● ● ● 6 . Vogel Pumpen VOGEL MULTISTAGE PUMPS Pumps sets: Accessories availables ● ● ● ● baseframes couplings coupling guards motors ● ● ● minimum flow valves speed control special accessories to meet customer requirements Sizes 84 up to 204 P are available in a space saving vertical design. up to 315 kW Flexible coupling between pump and motor Medium lubricated sleeve bearing in suction casing Maintenance friendly design. ● ● ● ● 7 . Type PVa: ● Vertical configuration with a separate thrust bearing. Grease lubricated with grease nipples. Bearings and shaft seal are maintainable without pump disassembly. design V1. Standard motor according to IEC. design V1 Flexible coupling between pump and motor Drive and discharge branch always above liquid level Medium lubricated sleeve bearings in pump body and shaft section. Number of bearings depending on installation length Suitable for variable speed control Mechanical seal or gland packing available Maintenance friendly design Suction bells.Vogel Pumpen VOGEL MULTISTAGE PUMPS Type PT: ● Vertical wet pit design Installation length: 1450/1750 r.m. 10 m Separate grease lubricated thrust bearing with grease nipples Standard motors according to IEC.p. suction strainers or foot valves available Can design available when pumping hot or volatile media Inducer design available for low NPSH applications when pumping volatile and warm liquids ● ● ● ● ● ● ● ● ● ● ● ● 8 . .max. version „k“ can be used without modification of the standard parts.Vogel Pumpen VOGEL MULTISTAGE PUMPS Shaft seal options: Mechanical seals: Seal chamber dimensions with comply ISO 3096. Single mech. 45 bar For more detailed information about operation limits with regard to material configuration and operation conditions please refer to data sheets or actual quotations. Gland packing: The availability of gland packings is limited to max. An internal flush system guarantees optimum lubrication and cooling of the seal faces. seal. Design U unbalanced up to max. Mechanical seals of all brands that comply with this standard and EN 12756. seal. 9 . are available. Design B balanced up to max. operation pressure of 25 bar. Above 25 bar operation pressure only mech.16 bar Single mech. Cartridge seals also minimize the maintenance cost arising while changing the seal. Single mechanical seal cartridge. The pumps are mostly used in fire fighting application to serve different pressure zones with different pressure levels. but also in vertical execution for design PVaM.Vogel Pumpen VOGEL MULTISTAGE PUMPS Shaft seal options: Cartridge mechanical seal Cartridge seals are pre-assembled units that guarantee trouble free mounting as well as reliability. Multioutlet configurations are not only available in horizontal execution for design PM. 10 . Double mechanical seal cartridge with connection for external flush. Pumps with more than one discharge Multioutlet design: Multistage pumps in Multioutlet design can be fitted with a random number of discharge branches. also available with Quench. 7040 1.6025 1. 480 BSI (UK) 1452 Gr. 40-60-18 A 216 Gr.6025 0.4021 1.4462 possible Elastics (O-rings) EPDM for hot water up to 140 o C.4021 1.4021 1.4408 0.7040 0.0619 0.4571 Kohle 1) 1) Carbon resin impregnated 2) Pure silicon carbide (without free silicone) Application limits regarding pressure.6025 0. WCB B 584 C 90700 A276 Type 420 A743 C F . 11 . Materials .6025 1.0619 1) 1) 1) 1) 0.6025 0.4021 1.6025 0.7 0 4 0 1 .4571 1.7040 1. data sheets.4021 1.4021 1.7040 0.0619 1. Optional materials upon request.6025 0.4462 1) Optional casing wear rings made of 1.4021 1.4408 1. 250 1083/400-12 1504 161 Gr. optional VITON (Pay attention to operation limits and chemical resistance) Temperature and pressure operating limits depending on the material version.4408 Material options 0.4462 1.6025 CC480 K 1.6025 0.4021 1.4021 1.6025 1.6025 0.6 0 2 5 0 .6025 1.4 0 2 1 1 . temperature and speed as well as chemical resistance refer to data sheets or actual quotations.4021 1.0619 1.4021 1.7040 1.6025 1.4408 0.8 M A 276 S 31803 Mechanical materials: Standard materials DIN Code BQ 1 EGG BQ 1 VGG Q1 Q1 VGG Gleitring Kohle SIC 2) 1) Sitzring SIC SIC SIC 2) 2) 2) Elastomere EPDM Viton Viton Metallteil 1.4 4 0 8 1 .6025 0.4 4 6 2 DIN 17006 EN-GJL-250 (GG 25) EN-GJS-400-15 (GGG 40) GP 240 GH (GS-C 25) CuSn10-C X20Cr13 G-X6CrNiMo18-10 X 2 Cr Ni MoN 22-5-3 683-13-4 970 420 S 37 3100-316 C16 1503 318 S13 420 CF8M IS O 185 / Gr.6025 0.4462 1.4021 1.6025 0.6025 0.Vogel Pumpen VOGEL MULTISTAGE PUMPS Materials: Material Code Impeller Diffusors Stage casing Suction casing Discharge casing Casing wear ring Sh a f t Sh a f t sleeves Standard materials N SN VN VV NL VL NF VF 0.6025 0.7040 0. please refer to techn. 220 AISI ASTM A 278 Class 30 A 536 Gr.4408 0.0 6 1 9 CC4 8 0 K 1 .6025 1.4021 1.Comparison of various standards DIN 17007 0 .4408 1) 1) 1) 1.4021 1.4408 0.4408 0.4571 1.0619 1.0619 0. Vogel Pumpen Pumpenfabrik ERNST VOGEL GmbH A-2000 Stockerau Ernst Vogel-Straße 2 Telefon: .com Liability of manufacturer and/or supplier The mentioned limits of operation and/or application are only a general information and may not be applied for every case. The permitted range of operation and/or application for the specific case is to be obtained from our acknowledgement of order and/or the instructions for installation.itt.com Liste 2300.vogel-pumpen.1.43-2266-65311 E-Mail: info@vogel... sent with the goods. operation and maintenance. www.43-2266-604 Telefax: .B 9/2007-e 12 .