Home
Login
Register
Search
Home
VM1_EN
VM1_EN
March 26, 2018 | Author: Michael Gabriel Suitella | Category:
Equipment
,
Components
,
Technology
,
Mechanical Engineering
,
Electrical Equipment
DOWNLOAD
Share
Report this link
Comments
Description
Vacuum circuit-breaker – VM1© ABB 13.10.2011 VM1 Vacuum circuit-breaker | 1 …2500 A.Vacuum circuit-breaker – VM1 Mechanical operating cycles a) Operating mechanism …100.000 b) Vacuum interrupter …30.000 12 kV.000 VM1 Vacuum circuit-breaker with magnetic actuator mechanism Operating cycles at rated short-circuit breaking current …30.2011 VM1 Vacuum circuit-breaker | 2 24 kV. …25 kA Breakers for 4000 A with fan cooling . …3150 / 40001) A. …50 kA 17.10. …40 kA 1) © ABB 13.5 kV. …3150 / 40001) A. Vacuum circuit-breaker – VM1 Withdrawable vacuum circuit-breaker module for air insulated switchgear © ABB 13.10.2011 VM1 Vacuum circuit-breaker | 3 . 10.Vacuum circuit-breaker – VM1 Vacuum interrupter (principle structure) 1 1 Stem / terminal 2 2 Twist protection 3 3 Metal bellows 4 4 Interrupter lid 5 5 Shield 6 7 8 6 Ceramic insulator 7 Shield 8 Contacts 9 Stem / terminal 9 10 © ABB 13.2011 VM1 Vacuum circuit-breaker | 4 10 Interrupter lid . 2011 VM1 Vacuum circuit-breaker | 5 8 Connection to drive .10.Vacuum circuit-breaker – VM1 1 Embedded pole (principle diagram) 1 Upper terminal 2 2 Vacuum interrupter 3 Stem 3 4 Lower terminal 5 Felxible connection 4 5 6 Insulated push-rod with contact force springs 7 Fixing point 6 7 8 © ABB 13. 5 kA 24 kV 24 kV 24 kV …1250 A …2500 A …2500 A …16 kA …20 kA …25 kA .10.5 kV …1250 A …1250 A …2500 A …2500 A …16 kA …25 kA …25 kA …31.5 kV 17.5 kV 17.5 kA 17.Vacuum circuit-breaker – VM1 Vacuum interrupters 1) Only with additional external insulation © ABB 13.5 kV 17.2011 VM1 Vacuum circuit-breaker | 6 VG5 VGE4 VG4 VG4-S 12 kV 12 kV 12 kV 12 kV …1250 A …1250 A …2500 A …2500 A …20 kA …25 kA …25 kA …31. 5 kA 36/40.10.5 kV …3150 A …31.5 kV …3150 A …3150 A …50 kA …40 kA 24/36 kV …3150 A …31.2011 VM1 Vacuum circuit-breaker | 7 .Vacuum circuit-breaker – VM1 Vacuum interrupters 1) Only with additional external insulation VG7 VG6 12 kV 12/17.5 kA © ABB 13. 5 kV 24 kV …1600 A …1250 A …40 kA …25 kA .5 kV …1250 A …31.10.5 kA © ABB 13.5 kV 12 / 17.2011 VM1 Vacuum circuit-breaker | 8 …3150 1) …40 kA A P3 P4 12 / 17.Vacuum circuit-breaker – VM1 Embedded poles 1) 2500 A and 3150 A with heat sink PT1 P2 12 / 17. Vacuum circuit-breaker – VM1 Embedded poles 1) 2500 A and 3150 A with heat sink P5 P7 24 kV …2500 1) …25 kA © ABB 13.5 kV A …3150 1) A …50 kA .2011 VM1 Vacuum circuit-breaker | 9 12 / 17.10. 10.Vacuum circuit-breaker – VM1 Emergency manual breaking mechanism Electric controller Electric energy store Magnetic actuator Sensor for switching position detection © ABB 13.2011 VM1 Vacuum circuit-breaker | 10 . 10.5 kV.000 operations (CO) . …2500 A.2011 VM1 Vacuum circuit-breaker | 11 12 kV. less than 16 and 10 ms for closing and opening of the breaker Mechanical endurance 2. …25 kA 17. …25 kA 12 kV. …25 kA 24 kV.Vacuum circuit-breaker – VM1 Fast VM1-circuit-breaker – type VM1-T © ABB 13. …1250 A. …2500 A. 2011 VM1 Vacuum circuit-breaker | 12 High reliability (according to DIN EN 61511-1 SIL3) Few individual parts Simple mechanical sequences High quality standard Environment friendly material Continuously product improvement Wide range of accessories Long life .Vacuum circuit-breaker – VM1 All benefits at a glance © ABB 13.10.
Report "VM1_EN"
×
Please fill this form, we will try to respond as soon as possible.
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
Copyright © 2024 DOKUMEN.SITE Inc.