User Manual Plantas Huawei



Comments



Description

TP48200T-D20A1 & D20A2 & D14A1 & D14A2 V300R001User Manual Issue Date 01 2012-06-01 HUAWEI TECHNOLOGIES CO., LTD. Copyright © Huawei Technologies Co., Ltd. 2012. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: Email: http://www.huawei.com [email protected] Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd i TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual About This Document About This Document Purpose This document describes the TP48200T-D20A1 & D20A2 & D14A1 & D14A2 in terms of its features, structure, components, installation, commissioning, and maintenance. Intended Audience This document is intended for:    Sales engineers Technical support personnel Maintenance personnel Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Alerts you to a high risk hazard that could, if not avoided, result in serious injury or death. Alerts you to a medium or low risk hazard that could, if not avoided, result in moderate or minor injury. Alerts you to a potentially hazardous situation that could, if not avoided, result in equipment damage, data loss, performance deterioration, or unanticipated results. Provides a tip that may help you solve a problem or save time. Provides additional information to emphasize or supplement important points in the main text. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd ii TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual About This Document Change History Changes between document issues are cumulative. Ltd iii .. The latest document issue contains all the changes made in earlier issues. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Issue 01 (2012-06-01) This issue is the first official release. ......................... ii 1 Overview.......3.... 37 2.............................................................................................2 Pins....................................... 33 2......4...................................................................2..................2 DC PDU ..................................................5................................................................................................................. 21 2.................................................. 23 2...........................................1 Appearance ................................................................................................................................... 36 2...2 Typical Networking ....................... 11 2..............1 Appearance .......................................................................................................................................1 Appearance ........... 1 1................. 33 2..............3 Specification ...................................................................................................................... 39 Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co................................................................................................................................................................................................................................. 1 1.............1 Direct-Cooling Unit ....... 24 2.......................................................................................................................4...........................................................................................................................................................................................................................7........1 Designation Explanation .......... 15 2.............................................. Ltd iv .............................. 32 2........................................................................... 21 2...............8 Bluetooth controller ........................................................2 Main Control Module............................................................... 35 2........................................................................................................5 GPRS antenna ............ 38 2................................................................................1 AC PDU ................................................................................................................................. 29 2.......3 Rectifier ...................................... 23 2...........................................................................................................1 Appearance ...................................2 Temperature Control Unit .......................................................................................... 9 2.4 Monitoring Unit ...........................................................................................5 PDU.1 Cabinet ..6............................................................................................................................................................................................................................4 Features .. 35 2.....................................................................3...............................................6.4........................................................................................................ 2 1.............................................................................. 38 2..................................................................................................................................7................................. 39 2...................................................................................7 Bluetooth electric door lock .......1 Appearance ...................................................................................................... 1 1........... 9 2..........................................................4 GPRS Module ....................................2 TEC .................. 8 2 Component Description.........................4.................................. 11 2..........................................................2 Panel..............................8.....................6................2..................................................................................................................................2 Pins.........................3 Configuration .................................................. 22 2........... 26 2..................................................................................TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual Contents Contents About This Document ........... 32 2...6 Intelligent Power Meter .......................................4...................................................5....................................................... 37 2............................................................................................3 Basic I/O module .................................................................................................................................................................................................. ............................................. 42 3............ 74 6.............................................................................................................................TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual Contents 2................1 Overview ................. 40 2.............................3 Specification ........................................... 78 A Technical Specifications ................ 74 6.................................. 42 4 Installation and Commissioning..................................................................................................................... 41 3..............4 Human Safety ........................................................................ 94 C Acronyms and Abbreviations ..................................................................................................................................... 39 2....................2 Local Safety Regulations ......................... 49 5....................................................................................................................9 Storage Battery .......................................................................................... 56 6 Monitoring Function ....................1 Routine Maintenance...................................................................................................................................................................... 41 3.......................................8........................................................................................................2 Troubleshooting.......... Ltd v ............................................................................................................................................................................3 Grounding Requirements .......................................................................................................6 Electrical Safety .............................. 42 3................................................................................................. 40 3 Safety Precautions ...................................................3 Component Replacment . 41 3..................................................................................................................................... 46 5...........................................2 Pins....................................................................................................................................................................................... 102 Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co...........................1 LCD User Interface .............................................................................................................................................................................................................................................................................................................. 46 5...8..........................................................................................5 Equipment Safety .......................................................................................................... 45 5 Maintenance ....................................................2 Web User Interface .......... 41 3....................... 90 B LCD Menu ............................................................. The TP48200T-D14A1 & D14A2 is an integrated outdoor backup alternating current-to-direct current (AC-to-DC) power system that employs -48 V. 50 A rectifiers and outputs a maximum of 100A current. Figure 1-1 TP48200T-D20A1 & D20A2 & D14A1 & D14A2 in the typical site power solution Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. alternating current distribution box (ACDB). and related devices constitute a site power solution. AC power supply. storage batteries.. 50 A rectifiers and outputs a maximum of 200A current. Figure 1-1 shows the positioning of the TP48200T-D20A1 & D20A2 & D14A1 & D14A2 in the typical site power solution. Ltd 1 .2 Typical Networking Overview The TP48200T-D20A1 & D20A2 is an integrated outdoor backup alternating current-to-direct current (AC-to-DC) power system that employs -48 V.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 1 Overview 1 1. automatic transfer switch (ATS). The TP48200T-D20A1 & D20A2 & D14A1 & D14A2.1 Designation Explanation 1. power distribution unit (PDU). PE) 110V three-phase five-line (L1. PE) 110V three-phase five-line (L1. monitoring unit. L2. N. intelligent power meter and Bluetooth electric door lock. rectifiers. L3.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 1 Overview 1. L2.    Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. L3. L3. PE) 110V dual-live-wire (L1. sensors. PE)              TP48200T-D20A2   110V dual-live-wire (L1. L2. L2. N. PE)              TP48200T-D14A1   220V three-phase five-line (L1. Table 1-1 Configuration Item TP48200T-D20A1 Composition  AC input mode  Cabinet (13U space for customer equipments and two-layer rack for storage batteries) R4850G1 (2 to 4 PCS) ECC500 PDU Intelligent power meter Bluetooth electric door lock Battery temperature sensor Temperature sensor in direct-cooling unit Temperature and humidity sensor Door status sensor Water sensor (optional) Smoke sensor (optional) Cabinet (13U space for customer equipments and two-layer rack for storage batteries) R4850G1 (2 to 4 PCS) ECC500 PDU Intelligent power meter Bluetooth electric door lock Battery temperature sensor Temperature sensor in direct-cooling unit Temperature and humidity sensor Door status sensor Water sensor (optional) Smoke sensor (optional) Cabinet (5U space for customer equipments and one-layer rack for storage batteries) R4850G1 (2 PCS) ECC500 220V three-phase five-line (L1.3 Configuration The TP48200T-D20A1 & D20A2 & D14A1 & D14A2 is a cabinet that houses the fans. PE) 220V single-phase three-line (L. N. N. N. N. L2. PE) 220V single-phase three-line (L. L2. Ltd 2 . N. PE) 220V single-phase three-line (L. PE) 110V dual-live-wire (L1.. N. Ltd 3 . N. PE)  PDU Intelligent power meter Bluetooth electric door lock Battery temperature sensor Temperature sensor in direct-cooling unit Temperature and humidity sensor Door status sensor Water sensor (optional) Smoke sensor (optional) Cabinet (5U space for customer equipments and one-layer rack for storage batteries) R4850G1 (2 PCS) ECC500 PDU Bluetooth electric door lock Battery temperature sensor Temperature sensor in direct-cooling unit Temperature and humidity sensor Door status sensor Water sensor (optional) Smoke sensor (optional)   220V single-phase three-line (L. PE)            Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. L2. PE)     TP48200T-D14A2  110V dual-live-wire (L1. N. L2.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 1 Overview Item Composition      AC input mode L3. TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 1 Overview Figure 1-2 TP48200T-D20A1 interior (1) Alternating current power distribution unit(AC PDU) (4) Intelligent power meter (7) Central monitoring unit type A (CMUA) for thermoelectric cooler (TEC) (10) GPRS antenna (13) Monitoring unit (ECC500) (16) Bluetooth Electric door lock (2) Door status sensor (5) Space for rectifiers (8) TEC (3) Direct current power distribution unit(DC PDU) (6) Space for customer equipments (9) Base (11) Fan assembly (14) Temperature and humidity sensor (17) Space for Bluetooth controller (12) CMUA for fan assembly (15) Air filter Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 4 TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 1 Overview Figure 1-3 TP48200T- D20A2 interior (1) Alternating current power distribution unit(AC PDU) (4) Intelligent power meter (7) Central monitoring unit type A (CMUA) for thermoelectric cooler (TEC) (10) GPRS antenna (13) Monitoring unit (ECC500) (16) Bluetooth Electric door lock (2) Door status sensor (5) Space for rectifiers (8) TEC (3) Direct current power distribution unit(DC PDU) (6) Space for customer equipments (9) Base (11) Fan assembly (14) Temperature and humidity sensor (17) Space for Bluetooth controller (12) CMUA for fan assembly (15) Air filter Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 5 TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 1 Overview Figure 1-4 TP48200T- D14A1 interior (1) Alternating current power distribution unit(AC PDU) (4) Intelligent power meter (7) Central monitoring unit type A (CMUA) for thermoelectric cooler (TEC) (10) GPRS antenna (13) Air filter (16) Bluetooth Electric door lock (2) Door status sensor (5) Space for rectifiers (8) TEC (3) Direct current power distribution unit(DC PDU) (6) Space for customer equipments (9) Base (11) Fan assembly (14) Monitoring unit (ECC500) (17) Space for Bluetooth controller (12) CMUA for fan assembly (15) Temperature and humidity sensor Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 6 D14A2 interior (1) Alternating current power distribution unit(AC PDU) (4) Intelligent power meter (7) Central monitoring unit type A (CMUA) for thermoelectric cooler (TEC) (10) GPRS antenna (13) Air filter (16) Bluetooth Electric door lock (2) Door status sensor (5) Space for rectifiers (8) TEC (3) Direct current power distribution unit(DC PDU) (6) Space for customer equipments (9) Base (11) Fan assembly (14) Monitoring unit (ECC500) (17) Space for Bluetooth controller (12) CMUA for fan assembly (15) Temperature and humidity sensor Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 7 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 1 Overview Figure 1-5 TP48200T.. High Protection Level The cabinet protection level is IP55..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 1 Overview 1. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Wide Range of AC Input Voltage The AC input voltage of the TP48200T-D20A1 & D20A2 & D14A1 & D14A2 ranges from 85 V AC to 300 V AC phase voltage. and the rectifier complies with underwriters laboratory (UL). Ltd 8 . Easy Installation The modules of monitoring unit (ECC500) and rectifiers are hot-swappable. the power distribution components comply with CE standards. High Efficiency The TP48200T-D20A1 & D20A2 & D14A1 & D14A2 uses rectifiers with a 96% efficiency record. The TP48200T-D14A1 & D14A2 supplies stable power to -48 V DC equipment and provides a maximum current of 100 A. Safety and Regulatory Design The TP48200T-D20A1 & D20A2 & D14A1 & D14A2 complies with Conformite Europeenne (CE) standards.4 Features The TP48200T-D20A1 & D20A2 supplies stable power to -48 V DC equipment and provides a maximum current of 200 A. saves maintenance time. and Technical Watch-Over Association (TUV) standards. This facilitates the system installation. and reduces the operational expenditure (OPEX). Remote Monitoring OPEX is reduced when the TP48200T-D20A1 & D20A2 & D14A1 & D14A2 performs comprehensive power management and battery management functions by connecting to the element management system (EMS). Low Imbalance Degree of Current Equalization The imbalance degree of current equalization for rectifiers is less than 5%. CE. 56 in.).56 in. x 27.56 in. Figure 2-1 TP48200T-D20A1 & D20A2 cabinet Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.1 in. x 27.. x 27.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description 2 2.56 in.). Figure 2-1 shows the TP48200T-D20A1 & D20A2 cabinet.09 in. x 27.1 Cabinet Component Description Dimensions (H x W x D) of the TP48200T-D20A1 & D20A2 cabinet (excluding the base) are 2060 mm x 700 mm x 700 mm (81. Ltd 9 . Dimensions (H x W x D) of the base are 180 mm x 700 mm x 700 mm (7. ]) for two layers  TP48200T-D14A1 & D14A2 5 U (222.]) AC PDU: 3 U (133.]) (not included the space for storage batteries) 16U (755.00 in.45mm [1.8 mm [7.75 in. x 27.09 in.9mm[3..]) for one layer  AC PDU: 3 U (133.). x 27.])  1U (44.9mm[3.85 mm [21.56 in.25 in.]) DC PDU: 4U (177. Dimensions (H x W x D) of the base are 180 mm x 700 mm x 700 mm (7. x 27.25 mm [8.50in.45mm [1.8 mm [7.6 mm [29.0 in.56 in.35 mm [5.75in.56 in.75 in.50in.])  2U (88.])    Monitoring unit (ECC500 Recitifers  1U (44.25 in. x 27. Figure 2-2 shows the TP48200T-D14A1 & D14A2 cabinet. Figure 2-2 TP48200T-D14A1 & D14A2 cabinet Table 2-1 TP48200T-D20A1 & D20A2 & D14A1 & D14A2 cabinet height distribution Item Customer equipment Storage batteries Embedded power system TP48200T-D20A1 & D20A2 13 U (557.])  2U (88.6 mm [14.).]) Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 10 .]) (not included the space for storage batteries) 8 U (355.35 mm [5.96 in.0 in.1 in.75in.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Dimensions (H x W x D) of the TP48200T-D14A1 & D14A2 cabinet (excluding the base) are 1400 mm x 700 mm x 700 mm (55.]) DC PDU: 4U (177.56 in. TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description 2.2 Temperature Control Unit 2.2.1 Direct-Cooling Unit The direct-cooling unit extends the area for exchanging air inside and outside the cabinet, speeds up air circulation, and reduces the operating temperature in the cabinet. The fan assembly houses two centrifugal fans. The fans direct air into the cabinet through the lower part of the door and out of the cabinet through the top cover of the cabinet. Appearance Figure 2-3 shows the fan assembly. Figure 2-4 shows a centrifugal fan. Figure 2-3 Fan assembly Figure 2-4 Centrifugal fan Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 11 TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Specifications Table 2-2 Technical specifications of fan assembly Item Rated voltage Rated power Specifications –48 V DC 2 x 34 W Air flows Figure 2-5 The direct-cooling unit air flows Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 12 TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description CMUA for fan assembly Figure 2-6 Ports of the CMUA (1) PWR (5) ELU (9) TEM.FAN (2) SMOKE (6) ALM & RUN Indicators (10)TEC (3) IN0, IN1, IN2 (7) COM_IN (11) FAN_INT (4) GATE (8) COM_OUT (12) FAN_EXT Table 2-3 Ports of the CMUA Silkscreen Function PWR SMOKE IN0, IN1, IN2 GATE ELU ALM & Indicators COM_IN COM_OUT TEM.FAN TEC RUN Power input port. Reserved. Reserved. Reserved. Reserved. Indicate CMUA status. Connects to the monitoring unit. Reserved. Connects to the temperature sensor. Reserved. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 13 Ltd 14 . and SW3 for setting its working mode in different cabinets. Blinks at 4 Hz. Figure 2-7 Jumper slots on the CMUA (plan view) Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.5 Hz. SW2. If the board does not communicate with the upper-level equipment within one minute. The board is not performing self-test after being powered on. the communication fails. Figure 2-7 shows jumper slots on the CMUA. No alarm is generated. Therefore.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Silkscreen Function FAN_INT FAN_EXT Connects to the fan on the left in the fan assembly.. the board must be replaced as required.5 Hz. Table 2-4 Indicator description Silk Screen RUN Color Green Status Blinks at 0. and the board must be replaced. An alarm is generated. ALM Red CMUA Jumper Slot The CMUA has three jumper slots SW1. Connects to the fan on the right in the fan assembly. but fails to communicate with the upper-level equipment. ON/OFF Steady off Steady on Blinks at 0. An alarm is generated. Meaning The board functions normally and communicates properly with upper-level equipment. The board functions normally. It may be caused by a fault on the board or in a port. Ltd 15 . an internal fan (cold-end fan)..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Figure 2-8 shows settings for jumper slots on the CMUA.2 TEC A TEC consists of semiconductor refrigeration chips. an external fan (hot-end fan). Figure 2-9 shows the TEC components. Appearance Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.2. a hot-end heat sink. Figure 2-8 Settings for Jumper slots on the CMUA 2. a cold-end heat sink. and a controller. Controller Specifications Table 2-5 Technical specifications Item Rated voltage (V DC) Rated refrigeration capacity (L32/L32) Maximum power input Heating capacity Ambient range Humidity range Storage environment Specifications –48 V DC 190 W 380 W 300W –40˚C to +40˚C 5%–100% RH –40˚C to +70˚C Complies with the ETS 300 019-1-1.. Hot-end heat sink 6. Internal fan 2.2 requirements. Cold-end heat sink 5. Ltd 16 . CLASS 2. Semiconductor refrigeration chip 4. CLASS 1.3 Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Figure 2-9 TEC components 1. External fan 3. Altitude Transportation performance ≤ 4700 m Complies with the ETS 300 019-1-2. TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Item Specifications requirements. including the flange) Weight Positive polarity protection of DC power supply Operating voltage Temperature sensor 10 years < 1% ≥ 70. (The withstand voltage is greater than 750 V DC. EN 60950-1.  Circular salt-fog test: The TEC passes the circular salt-fog test required by the IEC68-2-52 for 10 circles.4kg Supported 36V–60V Monitoring range:-20℃–80℃(± 2℃) Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. which complies with the IP3X requirement (Your fingers do not contact dangerous components in any direction. and UL 60950-1.000 hours > 100. UL94 V0 level of shielding materials and printed circuit board (PCB). Damp heat test: The TEC passes the damp heat test required by the IEC 68-2-38 for 10 days. IP protection level Anti-corrosion performance of the external air circulation system IP55 (cabinet). UL94 V1 level of other materials. UL94 HF-1 level of sealing materials.) Warning signs are attached to the internal fan.000 hours 200 mm x 180 mm x 400 mm 6. which complies with the International Electrotechnical Commission (IEC) 60529.) The internal fan is configured with a grille protection cover. Complies with the IEC 60950-1. Mould growth test: The TEC passes the mould growth test required by the IEC 68-2-10 for 28 days. Ltd 17 ..   Flame spread rating    Safety   Service life Failure rate Fan service life (internal fan L10/25˚C and external fan L10/40˚C) Mean time between failures (MTBF) Dimensions (H x W x D. Ltd 18 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Air flows Figure 2-10 TEC air flows Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. Reserved. Reserved.. Ltd 19 . Connects to the monitoring unit.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description CMUA for TEC Figure 2-11 Ports of the CMUA (1) PWR (5) ELU (9) TEM. Reserved. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.FAN (2) SMOKE (6) ALM & RUN Indicators (10)TEC (3) IN0. Connects to the temperature sensor. Reserved. IN2 GATE ELU ALM & Indicators COM_IN COM_OUT TEM. IN1. Reserved. Indicate CMUA status. IN2 (7) COM_IN (11) FAN_INT (4) GATE (8) COM_OUT (12) FAN_EXT Table 2-6 Ports of the CMUA Silkscreen Function PWR SMOKE IN0.FAN RUN Power input port. IN1. and the board must be replaced. Meaning The board functions normally and communicates properly with upper-level equipment. If the board does not communicate with the upper-level equipment within one minute. Table 2-7 Indicator description Silk Screen RUN Color Green Status Blinks at 0.. No alarm is generated. and SW3 for setting its working mode in different cabinets. Figure 2-12shows jumper slots on the CMUA.5 Hz. Connects to the external fan of the TEC. the communication fails. Blinks at 4 Hz. The board functions normally. An alarm is generated.5 Hz. The board is not performing self-test after being powered on. Connects to the internal fan of the TEC. SW2. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. but fails to communicate with the upper-level equipment. Ltd 20 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Silkscreen Function TEC FAN_INT FAN_EXT Connects to the TEC. the board must be replaced as required. It may be caused by a fault on the board or in a port. Therefore. ON/OFF Steady off Steady on Blinks at 0. ALM Red CMUA Jumper Slot The CMUA has three jumper slots SW1. An alarm is generated. TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Figure 2-12 Jumper slots on the CMUA (plan view) Figure 2-13 shows settings for jumper slots on the CMUA. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Figure 2-14 shows the rectifier.1 Appearance The rectifier converts the AC input power into stable -48 V DC power.3 Rectifier 2..3. Ltd 21 . The TP48200T-D20A1 & D20A2 & D14A1 & D14A2 can be configured with two. three. Figure 2-13 Settings for Jumper slots on the CMUA 2. or four rectifiers. The rectifier generates an alarm for shutdown due to ambient overtemperature or undertemperature protection. alarm indicator. Measures The rectifier runs properly. The rectifier generates a prewarning for power limiting due to overtemperature. Off Alarm indicator Yellow Off Steady on Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Figure 2-14 rectifier 2. and no measure is required. Replace the rectifier if the AC input is normal.3. No alarm is generated. and fault indicator.. Ltd 22 . Figure 2-15 shows the rectifier panel. No measure is required.2 Panel The rectifier panel provides the run indicator. The rectifier has no output. Figure 2-15 rectifier panel (1) Run indicator (2) Alarm indicator (3) Fault indicator Table 2-8 Indicator description of rectifier Indicator Run indicator Color Green Status Steady on Description The rectifier output is normal. Check that the air vent is not blocked and the ambient temperature is within a normal range. Figure 2-16 ECC500 architecture (1) Main control module (4) Basic I/O module (2) Filler panel (3) GPRS module Table 2-9 ECC component functions Component Main control module Silkscreen SMU03A Configuration Mandatory Function  Provides an LCD to query and set local parameters. Monitors and manages input energy. Blinking at 4 Hz The rectifier is loading an application program. Measures Check that the electrical grid voltage is within a normal range.. No measure is required. The rectifier is hibernated. and other modules are optional.4. The rectifier automatically recovers after loading. 2.4 Monitoring Unit 2. and no measure is required. There is no output because the rectifier is faulty. Pull out the rectifier and reinsert it after 1 minute. All modules in the ECC500 are hot-swappable.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Indicator Color Status Description The rectifier generates an alarm due to AC input overvoltage or undervoltage protection. Provides an operating status indicator. The rectifier is locked due to output overvoltage. a basic input/output (I/O) module. The main control module and Basic I/O module are mandatory. Fault indicator Red Off Steady on The rectifier is not faulty.   Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. No measure is required.1 Appearance The monitoring unit (model: ECC500) consists of a main control module. a GPRS module and three reserved slots. Replace the rectifier. Ltd 23 . TCP/IP stands for transmission control protocol/Internet protocol. smoke.2 Main Control Module Figure 2-17 shows the front panel of the main control module. Generates alarms. Figure 2-17 Front panel of the main control module (1) Indicators (4) Fast Ethernet (FE) port (2) LCD (5) RS485/RS232 port (3) Buttons (6) COM1 port Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Enables the ECC500 to communicate with the NetEco in out-of-band (by GPRS) mode. Intelligently manages storage batteries. Manages intelligent southbound components. Receives alarms generated by dry contacts and sensors for detecting battery temperatures. Monitors southbound components over serial ports. Provides RS485 ports for southbound communication.. Ltd 24 . Manages assets. water. Provides RS485 ports for southbound communication.4.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Component Silkscreen Configuration Function  Provides TCP/IP and RS485 ports for northbound communication. Provides six digital parameter input ports and two dry contact outputs. and ambient temperature and humidity.      Basic IO module MUS01A Mandatory    GPRS module MUC01A Optional   2. . enters a submenu from the main menu. The main control module runs properly but does not communicate with the NetEco properly. No critical or major alarm is generated. A critical or major alarm is generated. Returns to the previous menu without saving the settings of the current menu item. the standby screen is displayed if no button is pressed for 5 minutes.  After a menu is displayed. Buttons Table 2-11 Button description Button ▲ or ▼ Definition Up or down Cancel Enter Description Allows you to view menu items and set the value of a menu item.125s and then off for 0. or saves menu settings. Note:  After a menu is displayed. Enters the main menu from the standby screen.125s) Alarm indicator Red Off Steady on Description The main control module is faulty or has no DC input. The main control module runs properly and communicates with the NetEco.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual (7) COM2 port (8) Universal Serial Bus (USB) port 2 Component Description Indicators Table 2-10 Indicator description Silk Screen Run indicator Color Green Status Off Blinking (on for 1s and then off for 1s) Blinking (on for 0. Ltd 25 . LCD You can view information and set parameters on the LCD. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Table 2-11 describes the button functions. the LCD screen becomes dark if no button is pressed for 5 minutes. You can set and query parameters using the four buttons on the front panel. 3 Basic I/O module Figure 2-19 shows the front panel of the Basic I/O module. Ltd 26 . Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. connecting to the network or NetEco Reserved Reserved Reserved Reserved Figure 2-18 FE pin definition Table 2-13 FE pin definition Pin 1 2 3 6 Signal TX+ TXRX+ RXFE receive Description FE transmit 2.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Ports Table 2-12 Port description Silk Screen FE RS485/RS232 COM1 COM2 USB Description Northbound port..4. 125s and then off for 0.. Communication fails between the I/O module and the main control module.125s) ALM Red Alarm indicator Off Description The power supply is normal. Table 2-14 Indicator description Silk Screen PWR Color Green Meaning Power indicator Status Steady on Off Blinking (on for 1s and then off for 1s) Blinking (on for 0. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Figure 2-19 Front panel of the Basic I/O module (1)ELU (6)AI_1 (11)12V/1A (16)DC input terminals (2)SMOKE (7)AI_2 (12)COM1 (17)Indicators (3)DI_1 (8)TEM_HUM (13)GATE (4)DI_2 (9)WATER (14)COM2 (5)DI_3 (10)CAN (15)COM3 Indicators Table 2-14 shows the indicator description of the Basic I/O module. Ltd 27 . Communication is normal between the I/O module and the main control module. RUN Green Run indicator Reserved. The input/output (I/O) module is faulty or has no DC input. Connects to a smoke sensor. no alarm is generated. Connects to a southbound component. Default setting:  Description I2C&1-WIRE Direct-cooling unit alarm or TEC alarm TEC alarm Remarks Connects to an electronic label board.5 V Connects to the intelligent power meter. an alarm is generated. Ltd 28 .5–13.  COM2 COM3 DC input terminals Southbound RS485 port Southbound RS485 port RTN+ port: positive DC input terminal NEG–: negative DC input terminal Reserved. no alarm is generated. –48 V DC input port Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Ports Table 2-15 Port description Silk Screen ELU DI_1 DI_2 DI_3 AI_1 AI_2 TEM_HUM WATER SMOKE CAN 12V COM1 GATE Ambient temperature and humidity Water intrusion Smoke generation Southbound CAN port Power output ports Two-wire RS485 port Gate dry contact input Connects to a humidity and temperature sensor. If the dry contact is close. an alarm is generated. Default setting:  If the dry contact is open. If the dry contact is open. Connects to a water sensor. If the dry contact is closed. Reserved. 10.  Direct-cooling unit alarm 4-20mA analog input Connects to a battery temperature sensor. Ltd 29 .4..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Pin definition Figure 2-20 Pin definition Table 2-16 Pin definition Silk Screen Pin Pin definition WATER 1 2 3 4 12V WATER GND 12V ENV_TEMP 12V ENV_HUM TEMHUM 1 2 3 4 2. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.4 GPRS Module Figure 2-21 shows the front panel of the GPRS module. Ltd 30 . Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. The power supple is faulty or has no DC input. The GPRS module is faulty or has no DC input. The GPRS module is normal. Table 2-17 Indicator description Silk Screen PWR1 Color Yellow Status Steady on Off PWR2 Yellow Steady on Off GPRS Green Off Description The power supply is normal.. The GPRS module is not powered on.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Figure 2-21 Front panel of the GPRS module (1) DO_1 (5) DI_3 (9) ANT (2) DO_2 (6) DI_4 (10) Indicators (3) DI_1 (7) DI_5 (11) SIM card (4) DI_2 (8) DI_6 Frequency Band Upstream (module to BTS) : 824-849MHz/880 -915 MHz/1710 -1785 MHz/1850 -1910 MHz Downstream (BTS to module) : 869 -894 MHz/925-960 MHz/1805 -1880 MHz/1930 -1990 MHz Indicators The Table 2-17 describes the indicators. 1s and then off for 0. If the dry contact is open.9s) Blinking (on for 0. The ECC500 is searching for a network because of the absence of a subscriber identity module (SIM) card. no alarm is generated. as shown in Figure 2-22. Table 2-18 Port description Silk Screen DO_1 DO_2 DI_1 DI_2 DI_3 DI_4 DI_5 DI_6 Figure 2-22 Default setting of DI of GPRS module Dry contact input Default(If the dry contact is closed..). Definitions of DI_1 to DI_6 vary based on solution. but no data is being transmitted.1s and then off for 2. an alarm is generated. can be modified. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.025s) Blinking (on for 0. Function Dry contact output Remarks Reserved. You can query their definitions on the LCD. Ltd 31 . Ports Table 2-18 describes the ports of the GPRS module.1s and then off for 0. Data is being transmitted over GPRS.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Silk Screen Color Status Steady on Blinking (on for 0. The ECC500 is registered with the network.9s) Description A call is being set up over GPRS. The DC PDU distributes DC power to the TP48200T-D20A1 & D20A2 & D14A1 & D14A2. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. while the AC PDU distributes AC power.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description 2.5 PDU PDUs are classified into the DC PDU and AC PDU.. Ltd 32 .4.5 GPRS antenna Figure 2-23 GPRS antenna (1) GPRS antenna (2) GPRS module 2. the recommended AC output current summation should be less than 14A.5.2 DC PDU Figure 2-26 shows the DC PDU.1 AC PDU Figure 2-24 AC PDU of TP48200T-D20A1 & D14A1 Figure 2-25 AC PDU of TP48200T-D20A2 & D14A2 Table 2-19 Circuit breaker distribution Item AC input AC output TP48200T-D20A1 & D14A1 1 x 63A/3P MCB 3 x 10A MCB 1 x 10 A maintenance socket 1 x 10A RCD NOTE TP48200T-D20A2 & D14A2 1 x 100A/2P MCB 3 x 10A MCB 1 x 10 A maintenance socket 1 x 10A RCD If TP48200T-D20A1 & D20A2 is configured with four rectifiers. Ltd 33 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description 2. 2. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co..5. Ltd 34 ..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Figure 2-26 DC PDU Figure 2-27 TP48200T-D20A1 & D20A2 battery branch Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. 6 Intelligent Power Meter 2.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Figure 2-28 TP48200T-D14A1 & D14A2 battery branch Table 2-20 Circuit breaker distribution Item Battery low voltage disconnection(BLVD) Load low voltage disconnection(LLVD) Specification  10 x 10 A MCB 2 x 100A MCB 1 x 80A MCB 2 x 50A MCB 3 x 25A MCB 2 x 10A MCB      Battery branch TP48200T-D20A1 & D20A2:  2 x 125 A MCB 1 x 125 A MCB TP48200T-D14A1 & D14A2:  2..1 Appearance Figure 2-29 Appearance of intelligent power meter Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 35 .6. Ltd 36 .2 Pins Figure 2-30 Pins of intelligent power meter Table 2-21 Pins of the intelligent power meter Pin 1、2 3、4 5 6 7 8 10 Definition Working Power RS485 A phase voltage B phase voltage C phase voltage Zero-voltage line The current transformer interface Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.6..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description 2. 5%(10-100A)   Phase voltage: 0. Ltd 37 .0% 45Hz-60Hz ±0.5L) 2.1Hz 1. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.7 Bluetooth electric door lock The Bluetooth electric door lock can be connected to the Bluetooth controller.5C-1-0.3 Specification Table 2-22 Specifications of the intelligent power meter Category Voltage Item Measurement range Overload capacity Current Measurement range Overload capacity Power Single phase power Total power Measurement range Power factor Accuracy Measurement range Current Voltage Power Power factor Frequency Energy Specifications   Line voltage: 30V-600V Phase voltage: 20V-400V 800V 200Ma-100A 200A 0-48000 W/var/VA 0-96000 W/var/VA 45 Hz -60Hz -1 to 1 0.5% (20-400V) Line voltage:1.6..0% ( U*I) 1.0% (0.0% 1.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description 2. 7.7. Ltd 38 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description 2.2 Pins Figure 2-32 RJ45 female connector Table 2-23 Pins definition of the Bluetooth electric door lock Pin 3 6 8 Definition +12V Signal GND Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.1 Appearance Figure 2-31 Appearance of Bluetooth electric door lock 2.. Ltd 39 .2 Pins Figure 2-34 Pins of the Bluetooth controller Table 2-24 Pins definition of the Bluetooth controller Pin 1 2 3 4 5 6 7 8 9 Definition AC power input AC power input connect to Pin4 connect to Pin3 -12V +12V control the Bluetooth lock(+) control the Bluetooth lock(-) - Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.8 Bluetooth controller 2.1 Appearance Figure 2-33 Bluetooth controller 2.8.8.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description 2.. 2mm 193x110x90 mm -45º C a 85º C Dimensions Operating Temperature 2. Ltd 40 . NOTE Storage batteries are prepared by customer. 12V/100 Ah batteries for power monobloc) backup.8. The TP48200A-D14A1 & D14A2 can be configured with one group (4 pieces. 12V/100 Ah monobloc) batteries for power backup.3 Specification Table 2-26 Bluetooth controller specifications Item Rated current Rated voltage Operating Limit voltage Withstanding voltage 1 minute Insulation resistance at 500V DC Contact resistance at 1A DC Solder inter diameter Specifications 4A 125V 200V AC 1500V AC 1500MΩ 3 MΩ 1.G.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 2 Component Description Table 2-25 Connection between the Bluetooth controller and the Bluetooth electric door lock Pins of the Bluetooth controller 7 7 8 Pins of the Bluetooth electric door lock 3 6 8 Definition +12V Signal GND 2..9 Storage Battery Storage batteries store electrical energy and power loads when the D. and mains supply no power or insufficient power. The TP48200A-D20A1 & D20A2 can be configured with two groups (8 pieces. The maximum dimensions for each storage battery are 295 mm x 125 mm x 560 mm. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. and maintain Huawei equipment. To ensure safety of humans and the equipment. Conduct the electrical inspection carefully. and they must understand basic safety precautions to avoid hazards. you must follow the local laws and regulations. NOTE The safety precautions described in this section are also applicable to other Huawei equipment.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 3 Safety Precautions 3 3.3 Grounding Requirements Equipment to be grounded must meet the following requirements:   When installing the device. Huawei will not be liable for any consequence caused by the violation of the safety operation regulations and design. and "WARNING" marks in other documents do not represent all the safety instructions. They are only supplements to the safety instructions. The "NOTE". pay attention to the safety symbols on the equipment and all the safety instructions in this document.. The safety instructions in this document are only supplements to the local laws and regulations.2 Local Safety Regulations When operating Huawei equipment. always make the ground connection first and disconnect it at the end. read and follow all the precautions in this document before performing any installation or maintenance. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.1 Overview CAUTION Safety Precautions To minimize the risk of personal injury and damage to equipment. Ltd 41 Issue 01 (2012-06-01) . production. Only trained and qualified personnel are allowed to install. operate. 3. 3. Do not damage the ground conductor or operate the device in the absence of a properly installed ground conductor. "CAUTION". and usage standards. In the case of fire. remove packing materials from the equipment area. do not connect safety extra-low voltage (SELV) circuits to telecommunication network voltage (TNV) circuits. and an ESD wrist strap. and turn on the fire alarm bell or make an emergency call. 3. Before operating the device. To avoid electric shock. You must abide by the local rules and regulations when bridging and wiring AC cables.6 Electrical Safety High Voltage DANGER  The high voltage power supply provides power for the device operation. Non-standard and incorrect high voltage operations may result in fire and electric shock. Direct or indirect contact (through damp objects) with high voltage and AC mains supply may result in fatal danger. wear electrostatic discharge (ESD) clothes. 3.4 Human Safety       Do not operate the device or cables during lightning strikes. During the installation of the AC power supply facility. Do not touch the surface of such equipment parts to avoid getting burn. Do not wear jewelry or watches when you operate the device.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual  3 Safety Precautions The device (or system) must be connected permanently to the protection ground before an operation. 3. Do not enter a building that is on fire. After the installation. The personnel who install the AC facility must be qualified to perform high voltage and AC operations.5 Equipment Safety     The device must be fixed securely on the floor or to other immovable objects such as walls and mounting racks before operation. ESD gloves. Tighten the thumbscrews by using a tool after initial installation and subsequent access to the panel. Before operating the device.. The temperature of some equipment parts may be rather high. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. follow the local safety regulations. check the electrical connection of the device to ensure that it is securely grounded. Do not block the ventilation while the device is operating. immediately leave the building or the equipment room. Ltd 42     Issue 01 (2012-06-01) . CAUTION Outputs are energy hazards (>240 VA) Electrostatic Discharge CAUTION The static electricity generated by human bodies may damage the electrostatic-sensitive components on boards. To prevent electrostatic-sensitive components from being damaged by the static on human bodies. personal injury or device damage may be caused by high leakage current. which may cause fire or hurt human eyes. turn off the power switch. ensure that the device is dry. Avoid using ordinary tools. for example. the large-scale integrated (LSI) circuits. Transient contact between the core of the power cable and the conductor may generate electric arcs or sparks. switch off the power supply immediately. check that the label on the power cable is correct. These static electromagnetic fields cannot be eliminated until the static is discharged. When the operation is performed in a damp environment. Power Cable  Do not install or remove power cables when the device is on. High Electrical Leakage   Ground the device before powering it on. Before connecting a power cable. If a "high electrical leakage" tag is present on the power terminal of the device. friction between shoes and floors. you must ground the device before powering it on.   Power Output All output circuits are evaluated as SELV circuits.  Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual   3 Safety Precautions Dedicated tools must be used during high voltage and AC operations..  Human body movement. friction between human bodies and clothes. Otherwise. Ltd 43 . Before installing or removing the power cable. you must wear a well-grounded ESD wrist strap when touching the device or handling boards or application-specific integrated circuits (ASICs). When water is found in the rack or the rack is damp. or handling of plastic articles causes static electromagnetic fields on human bodies. TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 3 Safety Precautions Figure 3-1 shows how to wear an ESD wrist strap. Ltd 44 . Figure 3-1 Wearing an ESD wrist strap Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. . Ltd 45 . Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 4 Installation and Commissioning 4 Installation and Commissioning The detailed installation and commissioning refer to the TP48200T-D20A1 & D20A2 & D14A1 & D14A2 Quick Installation Guide. If faults are identified. clear them immediately. Check Method Measure the voltage. Maintenance Maintain TP48200T-D20A1 & D20A2 & D14A1 & D14A2 periodically based on site requirements.1 Routine Maintenance Table 5-1 Routine maintenance Maintenance Item Maintenance Task Check Item Whether the output voltage of the DC PDU is within the range of –42 V DC to –58 V DC. Ltd 46 . set the multimeter to DC. Measures  Output voltage Switch on the circuit breaker on the DC PDU. The recommended maintenance interval is 6 months.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance 5 5. Repair When The voltage is beyond the range of –42 V DC to –58 V DC. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. and then measure the output voltage of the DC PDU. Repair When A component burns. or produces an unusual odor Check Method Observe and smell the component.   Fan Whether the fan is covered by dust Whether the fan surface is damaged and whether the rotational speed. replace it.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Maintenance Item Maintenance Task Check Item Whether a component burns. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Polish the rust and repaint the cabinet. Replace the fan. Door lock Observe and open the lock. sparks. noise.  Cabinet surface Whether the paint and the electroplated coating on the surface of the cabinet are in good condition Whether surface rust appears on the door lock and rust continues to spread over the surface View the cabinet surface. and vibration are in the normal range View the fan. smokes. sparks. If there is a burnt componen t. Ltd 47 . If a cable diameter does not match the load. or produces an unusual odor. Measures  Component If a short circuit occurs. rectify the fault. The fan is damaged. replace it.  Clear the dust on the fan. Surface rust appears on the cabinet or paint peels off. The fan rotates unstably or slowly. smokes. Replace the lock. Dust accumulates on the fan.. The door lock is too rusty.  Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Replace the air filter. and foreign matter using a brush or cotton cloth. Environment inside the cabinet Whether there are fingerprints or any other stains on the interior of the cabinet Whether there is unnecessary adhesive tape or cable ties on the cables Whether there is tape. or packing bags in the cabinet   Air filter Whether the air filter is covered by dust View the air filter.  Overtemperature alarms are frequently raised for the power system. cable ties. wastepaper. fingerprints. Measures Clean up stains.. Repair When There is foreign matter. Dust accumulates on the air filter. Ltd 48 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Maintenance Item Maintenance Task Check Item  Check Method View the interior of the cabinet. fingerprints. and the temperature inside the cabinet is much higher than the ambient temperature. or stains in the cabinet. check whether faults such as short-circuit or open circuit exist on the AC input loop. If the power-off duration is long. reconnect the cable. contact the mains supplier for troubleshooting. and check whether the AC undervoltage (lower than 180V AC) alarm is generated. If the insulation layer is aged.G.. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. If the cable is not correctly and securely connected. If the AC input is the mains supply.G.. AC power off  AC input cable fault Grid fault or D.. fault  2. by referring to the Diesel Generator User Manual. replace the cable.G. 4. reconnect the cable. 3. AC input cable fault Grid fault or D. replace the cable. 3. check whether there is short-circuit or electric leakage on the AC input loop.G. supply DC power using batteries. Check whether the AC input switch is OFF. start other systems for power supply.  2. If the AC input is from the D. fault 1.2 Troubleshooting Common Faults Table 5-2 Common faults and troubleshooting methods Fault Type AC phase loss Fault Analysis  Handling Method 1. If there is short-circuit or electric leakage. If the power-off duration is short. contact the mains supplier for troubleshooting. Check whether the AC input voltage is excessively low using a multimeter. If the AC input is the mains supply. If the cable is not correctly and securely connected. by referring to the Diesel Generator User Manual. check the D.G. If the AC input switch is OFF.G.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance 5. If the AC input voltage is excessively low and the AC undervoltage alarm is generated. Check whether the DC input cable is correctly and securely connected. Ltd 49 . check the D. Check whether the DC input cable is correctly and securely connected. If the AC input is from the D. Check whether the battery loop is short-circuited or has other faults. Check whether the AC undervoltage or overvoltage alarm threshold is properly set.  2. by referring to the Diesel Generator User Manual. replace them. check the D. 3.G. If the threshold is excessively high or low. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. and then insert each rectifier one by one. When the storage battery is powering the load. If the thresholds are not proper. reset the thresholds according to the actual conditions. insert it correctly. If the batteries are faulty. Check whether the rectifier module is in position or whether contact is proper.G. Check whether the batteries are faulty. remove all the rectifiers. If an overvoltage alarm is generated after a rectifier is inserted. Ltd 50 . Check the alarm thresholds of the DC overvoltage and undervoltage.  Charging overcurrent  Communication failure between modules Battery loop fault 1. lower or raise the threshold according to the actual conditions. If the AC input is the mains supply.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Fault Type AC overvoltage and undervoltage Fault Analysis  Handling Method 1. Improper setting of monitoring unit AC undervoltage or overvoltage threshold Mains supply grid fault or D. contact the mains supplier for troubleshooting.  DC overvoltage or DC undervoltage  1.. If the monitoring unit is inserted in an incorrect position. Then replace the rectifier.G. fault Improper setting of monitoring unit DC undervoltage or overvoltage threshold Rectifier module fault 2. the voltage of the rectifier exceeds the upper threshold. remove and then insert it.. 2. If the contact is not proper. If the AC input is from the D. Battery shutdown  Improper setting of monitoring unit battery parameters Contactor fault 1. If the temperature sensor is faulty. Check whether the contactor is faulty and whether it can be connected and disconnected.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Fault Type Load shutdown Fault Analysis  Handling Method 1. connect it correctly. 4. Check whether the battery cables or the connectors are faulty. Check whether the load detection cable is securely connected. Ltd 51 . Check whether batteries are faulty.  Output undervoltage due to greater load power than 4. Switch the load circuit breakers to ON after repairing the load circuit. 2. If the load power exceeds the maximum supported power of the system. 3. Check whether the mains supply is off or the voltage of storage batteries is lower than the “Battery Shutdown Voltage”. Check whether temperature sensor is faulty. If it is set excessively high. lower the load power. Contactor fault Battery fault Temperature sensor fault 2. configured rectifier module power 5. Check whether cables of the battery loop or connectors are faulty. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. If the contactor is faulty. 3. If the cables or connectors are faulty. If the load circuit breakers switch to OFF. replace them. replace it.. Check whether the load power is higher than the configured rectifier module power. replace it. Check whether the monitoring unit load shutdown voltage is set excessively high. add a rectifier module. replace them. Check whether the battery shutdown permission is set. If the cables or connectors are faulty. If the load power is higher than the configured rectifier module power.  4. If the contactor is faulty. Check whether the contactor is faulty and whether it can be connected and disconnected. If the cable is not connected securely. Check whether the contactor is faulty and whether it can be connected and disconnected. Battery fuse failure     Battery loop fault 1. replace them. replace it. 3. Load circuit breaker set to OFF Contactor fault Excessively high setting of monitoring unit load shutdown voltage   2. If the contactor is faulty. set it according to the actual situation. If the batteries are faulty. check whether the load circuit is short circuit or overcurrent. replace it. If the temperature sensor is faulty. If thresholds are not proper. Check whether the floor of the shelter is wet. If the charging current is still excessively strong. Check whether monitoring unit humidity alarm thresholds are set according to local conditions. 3. If the alarm persists when the humidity is proper.   Check the charging current. switch equalized charging to float charging and check whether the charging current is weakened. alarm can be cleared when temperature is lowered. Check whether the temperature sensor is faulty. adjust the current limit to reduce the charging current.. check whether the humidity sensor is faulty. If the current is excessively strong. Check whether the temperature control device in the shelter is faulty.) Fault Analysis  Handling Method 1. If the thresholds are not proper. repair it. the the the the  Ambient overhumidity or underhumidity alarm (The alarm is generated only when the humidity sensor is installed. Check whether monitoring unit battery temperature alarm thresholds are properly set. 4.  2. set the thresholds accordingly. replace it. 1. set the thresholds accordingly. If the thresholds are not proper. replace it. set thresholds accordingly. If the floor is wet. replace the faulty battery.)  1. unit set the the Improper setting of monitoring unit temperature alarm parameters  Overtemperature or 2. Check whether the temperature sensor is faulty. Check whether monitoring temperature alarm thresholds are according to local conditions. If the temperature sensor is faulty. If temperature is excessively high. 3. The alarm is automatically cleared when the temperature in the shelter is adjusted to the proper range.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Fault Type Ambient overtemperature or undertemperature alarm (The alarm is generated only when the temperature sensor is installed. Check whether the temperature in battery room is excessively high.  Battery overtemperature or undertemperature alarm   2. use a cotton cloth to wipe the floor and ensure it is dry or use other dehumidifiers. undertemperature in the shelter with the temperature sensor Temperature sensor fault Improper setting of monitoring unit humidity alarm parameters Overhumidity or underhumidity in the shelter with the humidity sensor Humidity sensor fault Battery cabin overtemperature Improper setting of monitoring unit battery temperature alarm parameters Battery charging overcurrent Temperature sensor fault 3. If the temperature control device is faulty. Ltd 52 . If the preceding steps do not work. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Check whether the ALM indicator on the panel of the rectifier module is on.  2. Ltd 53 . If the rectifier module is faulty. use a cotton cloth to wipe the floor and ensure it is dry or use other dehumidifiers. If the alarm persists. Rectifier module fault  Poor contact of the rectifier module Rectifier module fault 1..  Smoke in the shelter Smoke sensor fault 1.) Fault Analysis  Handling Method 1. Check whether the smoke caused by fire pervades in the shelter. If there is fire. check whether the door status sensor is faulty. check whether the rectifier module is proper. negotiate with the maintenance personnel of the electricity department to improve the power supply network. check whether the smoke sensor is faulty. Disconnect AC input to the rectifier module and restart the rectifier module later on. If the floor is wet. check whether the water sensor is faulty. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Check whether the mains voltage is over the AC overvoltage alarm threshold (300 V) of the rectifier module or below the AC undervoltage alarm threshold (85 V). Opened cabinet door Door status sensor fault   Shelter water accumulation Water sensor fault 1. Check whether the floor of the shelter is wet. replace it. If the alarm persists after the water is drained. If the alarm persists after the cabinet door is closed. Rectifier module shutdown Rectifier module protection  Input overvoltage or undervoltage of the rectifier module Rectifier module fault 1. If the alarm persists when there is no smoke. 2.) Water immersion alarm (The alarm is generated only when the water sensor is installed. The alarm is cleared after the cabinet door is closed. extinguish the fire and ventilate the shelter.) Smoke alarm (The alarm is generated only when the smoke sensor is installed.  2.  2. If the alarm persists when the input voltage of the rectifier module is proper. remove the rectifier module and insert the rectifier module after the indicator is off. replace the rectifier module. If the ALM indicator is on.  2. For the power supply network with long-time overvoltage or undervoltage.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Fault Type Door alarm (The alarm is generated only when the door status sensor is installed. If it is. replace the rectifier module. the fuse is normal. switch it to the ON position. If the monitoring unit is inserted in an incorrect position. If the color of the window is red. Check whether the load circuit breaker is in the OFF position.  Load Fuse Alarm  1. AC surge protector fault  AC surge protector fault User interface module fault 1. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Load circuit breaker set to OFF   2. Check the observation window on the AC surge protector. Check whether the load fuse is damaged. 3. insert it correctly. check the new fuse. If the voltage is close to 0 V. If the cable connection is proper. Signal cable connection fault of the rectifier module Rectifier module out of position Poor contact of the rectifier module Rectifier module fault The load fuse is faulty. connect it correctly. Replace the fuse. In this case. If the contact is not proper. 3. If the new fuse is blown or the load circuit breaker is automatically switched to the OFF position. If the cable is not connected securely.  2. Replace the user interface module.  Check whether the load fuse detection cable is securely connected. Ltd 54 . Check whether the fault detection cables of the AC surge protector are correctly connected or whether the cables are in good condition. remove and then insert it. Otherwise. 2. the load power on this route may be excessive or a short circuit may occur. If the cables are not in good condition. it indicates that the alarm loop is faulty. you need to rectify the fault on this load loop. If the alarm persists. 4. replace the surge protector.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Fault Type Communication Failure between rectifier and monitoring unit Fault Analysis  Handling Method 1.. If the alarm persists after the fuse is replaced. replace and reconnect them. Check whether the rectifier module is in position or whether contact is proper. Use a multimeter to measure the voltage at both ends of the fuse. the fuse is blown. Possible Cause The semiconductor refrigeration chips are faulty.internal fan. Table 5-3 describes the TEC faults and troubleshooting measures.  If the cables to the fans are damaged. The spare parts for a TEC includes temperature sensor. If no fault is located. the ALM indicator turns on. the RUN indicator turns on. the resistance in the dry contact is high and the ALM indicator is steady on. and the ALM indicator turns on. Cables to the fans are damaged.   The cables to the temperature sensor are damaged. If an alarm is still generated. and no alarm is generated. and no alarm is generated. Measures  Check that no input undervoltage or overvoltage occurs. Ltd 55 . replace the damaged power cable. Table 5-3 TEC faults and troubleshooting measures Symptom The internal and external fans rotate properly. the RUN indicator turns on.  If the input voltage is greater than 4 V. it transmits alarm signals over one dry contact to EMS software. Check that cables properly connect to the semiconductor refrigeration chips. the semiconductor refrigeration chips do not work. external fan and TEC refrigeration module.. reinstall internal and external fans. If the input voltage is lower than 4 V.   The input voltages before and after the internal and external fans start are not within normal ranges. replace the cables. the internal and external fans rotate properly. replace the CMUA. If all components are normal but an alarm is generated.When a CMUA is transmitting alarm signals. the TEC circuit breaker trips. the resistance in the dry contact is low and the RUN indicator is steady on. and an alarm is generated. The semiconductor refrigeration chips refrigerate properly. replace the TEC refrigeration module or control board . replace the CMUA. The external fan rotates properly. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance TEC faults When a TEC becomes faulty.   CMUA faults When a CMUA is working properly. disconnected. broad Measure the input voltage. replace the control board. and the RUN indicator turns on. or broken.   Replacing the rectifier To replace the rectifier. Take measures to ensure that important loads are always connected during the replacement. Check that power cables connect to the correct polarities. For example. and the ALM indicator and RUN indicator turn off. and then remove the rectifier from the plug-in subrack. perform the following steps: Step 1 Loosen the screws on the rectifier panel using a flat-head screwdriver. Ltd 56 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Table 5-4 CMUA faults and troubleshooting measures Symptom The host generates an alarm. Control burned out. If no fault is located. ----End Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Possible Cause  Measures   No DC power is supplied to the TEC. Step 2 Pull the handle of the rectifier outwards. Check the power supply circuit breaker. Step 5 Tighten the screws on the handle. Then. as shown in Figure 5-1.3 Component Replacment  Load disconnection is prohibited when you replace the main components.. Step 3 Insert the rectifier into the corresponding slot in the plug-in subrack. as shown in Figure 5-2. Secure the alarm cable. If a load must be disconnected. keep the circuit breaker of important loads set to ON and storage batteries and AC input are not cut off. Step 4 Slide the rectifier into the plug-in subrack slowly along the guide rails. Then. The alarm signal is loose. loosen the screws on the handle and pull out the handle. 5. lock the handle.    The host generates an alarm. ask for the customer's prior permission. The rectifier and the monitoring unit are hot-swappable. Step 4 Grasp the handles of the new module. Insulate the cables in time and stamp labels.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-1 Removing the old rectifier Figure 5-2 Installing the new rectifier Replacing the monitoring module To replace a module in the ECC500. perform the following steps: Step 1 Remove the signal cables from old module. Step 2 Loosen the captive screws on the old module anti-clockwise using the M3 screwdriver. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. as shown in Figure 5-3. and insert the module into the corresponding slot in the ECC500 subrack. Step 3 Pull out the old module by grasping the handle with both hands.. Step 5 Push the new module until its front panel is level with that of the ECC500 subrack. Ltd 57 . Ltd 58 . perform the following steps: Step 1 Remove the faulty SPD.. Step 2 Insert the new SPD. Step 9 If the main control module is replaced.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Step 6 Fold the handle. as shown in Figure 5-4. Step 7 Tighten the captive screws using the M3 screwdriver. set parameters by referring TP48200T-D20A1 & D20A2 & D14A1 & D14A2 Quick Installation Guide. Step 8 Connect the cables to the module according to the labels on the cables. ----End Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. ----End Figure 5-3 Pulling out the old module Figure 5-4 Installing a new moudle Replacing the AC SPD To replace the AC SPD. remove the circuit breaker. Step 3 Press the contact plate at the bottom of the circuit breaker using a flat-head screwdriver. Step 4 Press the contact plate at the bottom of the circuit breaker using a flat-head screwdriver again to install the new circuit breaker in the correct position. push the contact plate upwards using the screwdriver. as shown in Figure 5-7. Step 6 Set the circuit breaker to ON and connect power supply of this circuit breaker. perform the following steps: Step 1 Disconnect the power supply of a circuit breaker. Then..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-5 Replacing the AC SPD Replacing Circuit breakers To replace a circuit breaker. For example. disconnect the DC input and set the circuit breaker to OFF before replacing the input circuit breaker. Step 2 Remove the cables or copper bars connected to the circuit breaker using a Phillips screwdriver. ----End Figure 5-6 Removing the circuit breaker Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Then. Step 5 Install the cables or copper bars to the circuit breaker using a Phillips screwdriver in the same way. and then wrap the cables or copper bars using black PVC insulation tape to avoid hazards. as shown in Figure 5-6. Ltd 59 . Record the installation positions of the cables. and then remove the holder. Step 5 Install the holder of the new temperature and humidity sensor on the cabinet by securing the captive screws..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-7 Installing the circuit breaker Replacing temperature and humidity sensor To replace a temperature and humidity sensor. Ltd 60 . ----End Figure 5-8 Temperature and humidity sensor (1) Cover of the temperature and humidity sensor (2) Holder of the temperature and humidity sensor (3) Screw on the temperature and humidity sensor holder Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Step 6 Install the cover on the holder of the temperature and humidity sensor. as shown in Figure 5-8. Step 4 Correctly connect the cables to the wiring terminal on the new temperature and humidity sensor holder and secure the crimping screws by using the small flat-head screwdriver. and then remove the cables. and then remove the cover of the temperature and humidity sensor. perform the following steps: Step 1 Open the front door of the cabinet. press the latch in the front of the temperature and humidity sensor. Step 3 Loosen the crimping screws on holder of the temperature and humidity sensor by using the flat-head screwdriver. Step 2 Loosen the two screws on holder of the temperature and humidity sensor. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Replacing Fan assembly To replace the fan assembly.. as shown in Figure 5-10. Ltd 61 . perform the following steps: Step 1 Switch off the circuit breaker of the fan assembly. Step 2 Loosen the screws on top of the cabinet as shown in Figure 5-9. Figure 5-9 Loosen the screws on top of the cabinet Step 3 Open the top cover and secure the butterfly nut. as shown in Figure 5-11.. Ltd 62 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-10 Open the top cover Step 4 Remove the power cables of the fans. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Step 5 Loosen the screws on top of the fan assembly. . as shown in Figure 5-12. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-11 Removing the fan assembly Step 6 Install the new fan assembly. Step 9 Tighten the screws on top of the cabinet as shown in Figure 5-13. Step 8 Close the top cover. Figure 5-12 Installing the fan assembly Step 7 Install the power cables of the fans. Ltd 63 . 2. as shown in Figure 5-14. Step 2 Remove the TEC refrigeration module. Ltd 64 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-13 Tighten the screws on top of the cabinet ----End Replacing TEC To replace the TEC. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Switch off the TEC circuit breaker on the DC PDU or power system. perform the following steps: Step 1 Power off the TEC. 1.. Remove the power cables and alarm cables. Install the dry contact alarm cables to the correct poles. 1. 3. ----End Replacing CMUA To replace the CMUA. Install power cables to the correct poles. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Secure a new TEC refrigeration module to the door using the removed screws. Step 4 Power on the TEC. 2. Power on the TEC for a self-check and a refrigeration function test. 1. 2. Switch on the TEC circuit breaker on the DC PDU or power system. 4. After the TEC runs properly for 5 minutes.. Reinstall the cover to the temperature control door using the removed screws.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-14 Removing the TEC refrigeration module Step 3 Install a new TEC refrigeration module. as shown in Figure 5-15. perform the following steps: Step 1 Switch off the CMUA circuit breaker on the DC PDU or power system. 4. Remove the two M4 screws from the CMUA cover. Step 2 Remove the CMUA. Check that the ALM indicators on the temperature controller and monitoring device turn off. check the refrigeration function. 1. and then remove the CMUA cover. 3. Ltd 65 . Connect all the removed cables to the CMUA. 2. Install a new CMUA board using the four removed screws.2. Check that the ALM indicators on the temperature controller and monitoring device turn off. Reinstall ther cover using the two removed screws. Install jumper caps on the jumper slot. Switch on the CMUA circuit breaker on the DC PDU or power system.1 CMUA Jumper Slot or 2. by referring to 2. Power on the CMUA for a self-check and a refrigeration function test. After the CMUA runs properly for 5 minutes.2 CMUA Jumper Slot. Label the cables and then remove these cables. Figure 5-16 Removing the CMUA board Step 3 Install a new CMUA board. 1.. 3. Remove the four M3 screws on CMUA board and then remove the CMUA board . 4.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-15 Removing the CMUA cover 2. ----End Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.2. 1. Step 4 Power on the CMUA. 3. 3. Ltd 66 . 2. check the refrigeration function. as shown in Figure 5-16. 4. perform the following steps: Step 1 Loosen the screws with the crosshead screwdriver and then remove the air filter.. ----End Figure 5-17 Removing the air filter Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Replacing the Air filter To replace the air filter. Step 2 Install the air filter in the original position and fasten the screws with the crosshead screwdriver. Ltd 67 . Ltd 68 . Step 2 Unscrew the lock cylinder to be replaced using a Phillips screwdriver.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Figure 5-18 Installing the air filter Replacing the Door lock cylinder To replace the lock cylinder. Step 3 Secure a new lock cylinder using screws. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. ----End Figure 5-19 Replacing the lock cylinder Replacing the Door lock To replace the lock. perform the following steps: Step 1 Open the door lock using a key to the degree as shown in the following figure. perform the following steps: Step 1 Disconnect the cable between the Bluetooth controller and the door lock. Step 2 Unscrew the lock rod to be replaced using a Phillips screwdriver.. ----End Figure 5-20 Replacing the door lock Replacing the Door status sensor To replace the door status sensor. Step 4 Secure a new lock using screws.. as shown in Figure 5-21. Step 4 Install a new door status sensor in position and tighten the screws. perform the following steps: Step 1 Open the front door and remove the case of the door status sensor. Step 3 Loosen the screws on the door status sensor and then remove the sensor. Step 5 Connect the cable between the Bluetooth controller and the door lock. Figure 5-21 Removing the case of the door status sensor Step 2 Record the connections of the alarm cables and then disconnect them.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Step 3 Remove the door lock. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 69 . TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Step 5 Install the alarm cables of the new door status sensor according to the recorded connections. Then.. ----End Replacing the Intelligent Power Meter To replace the intelligent power meter. Ltd 70 . Step 4 Install the baffle plate and tighten the screws. Step 2 Press the contact plate at the bottom of the intelligent power meter using a flat-head screwdriver. ----End Figure 5-23 Installing the intelligent power meter Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. remove the intelligent power meter. perform the following steps: Step 1 Loosen the screws on the baffle plate and then remove the baffle plate. Figure 5-22 Removing the intelligent power meter Step 3 Press the contact plate at the bottom of the intelligent power meter using a flat-head screwdriver again to install the new intelligent power meter in the correct position. and then install the case. Figure 5-25 Removing the GPRS antenna Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. Figure 5-24 Removing the GPRS cable Step 2 Remove the GPRS antenna. as shown in Figure 5-25. Ltd 71 . perform the following steps: Step 1 Remove the GPRS cable from the GPRS module. as shown in Figure 5-24.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Replacing the GPRS antenna To replace the GPRS antenna. as shown in Figure 5-26. Ltd 72 . Figure 5-27 Installing the GPRS cable Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Step 3 Install the GPRS antenna. as shown in Figure 5-27.. Figure 5-26 Installing the GPRS antenna Step 4 Installing the GPRS cable to the GPRS module. TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 5 Maintenance Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. Ltd 73 . The parameter values in Figure 6-1 are for reference only. This section describes how to query active alarms on the LCD. English or other language by pressing ▲ or ▼ and enter the standby screen by pressing Enter. The alarm severity and date are displayed alternatively.1 LCD User Interface Selecting a Display Language Querying Active Alarms Monitoring Function After the ECC500 is powered on. Figure 6-1 Querying active alarms NOTE 110215 indicates February 15. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. You can select Chinese.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function 6 6. as shown in Figure 6-1.. Ltd 74 . the screen for selecting a display language is displayed. 2011. and Control page.. as shown in Figure 6-2. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Quick Setting page. The parameter values in Figure 6-2 are for reference only. You can add or delete users. Ltd 75 . Figure 6-2 Setting parameters quickly NOTE To open the Settings page. you need to enter a password. and change the user name and password. The default user name is admin and the default password is 001.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Setting Parameters Quickly This section describes how to quickly set the number of battery strings and rated battery capacity on the LCD. TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Setting Alarm Parameters Figure 6-3 Setting alarm parameters Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 76 .. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 77 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-4 Setting DO alarm status LCD Menu Hierarchy Figure 6-5 shows the LCD main menu.. host communications addresses and baud rates under master/slave protocol. battery status. and active alarm information. including IP addresses. alarm severities. site and storage battery type. Set the IP address. Configure network parameters. Configure site information including date and site name and deal with configuration files and so on. Upgrade software online. Configure system parameters. Query electronic label information. save. Ltd 78 . download.. and change user names and passwords. Add or delete users. Configure alarm parameters. Set the system date and time. gateway. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-5 LCD Menu hierarchy Main Menu Active Alarm Running Status Settings Control Quick Settings Site Summary Alarm Setting Site Summary Qty of Battery PSU Summary Site Summary Batt Summ Rated Capacity PSU PSU Summary PSU Summary Set Date Batt Summ VRLA Batt Summ PSU Set Time VRLA Batt LVD Setting Clr Alarm Hist IP Address ECC500 ECC500 Subnet Mask GPRS Comm Para Gateway Alarm History System Para Batt Test Log 6. Control the system. Query and export historical logs and alarms. including the PSU status.2 Web User Interface You can perform the following operations over the WebUI:            View the system status. such as choosing battery boost or floating charge and resetting PSUs. and upload configuration files. and subnet mask of the SMU on the LCD before logging into the WebUI. and the relationship between alarms and dry contacts. Step 4 On the login page shown in Figure 6-6. Setting method as follows: Step 1 Open the Internet Explorer.. and gateway on the LCD based on those assigned by the customer. Ltd 79 . ----End Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. choose Internet and click Customer Level as shown in Figure 6-7. please set Local intranet in the same method. Step 3 On the Security tab. Step 2 Choose Tools > Internet Options. Step 4 Select Enable under Initialize and script ActiveX controls not marked as safe. After set Internet. and then press Login. need to set the Internet Explorer. Step 3 Enter the IP address of the SMU in the Internet Explorer address box and press . subnet mask. set User Name to admin and Password to 001.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Login Web Page Step 1 Connect an SMU to an Ethernet. Figure 6-6 Login page Setting the Internet Explorer Make sure exporting historical logs successfully. Step 2 Set the IP address. ----End Querying System Status To view the information about the site. Ltd 80 . PSUs. batteries. TCU and fan. power distribution. as shown in Figure 6-8 Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. click System Status.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-7 Internet options interface Step 5 Select Enable for all the options... active alarms. TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-8 System Status Configuring System Parameters You can configure the site. Ltd 81 . and batteries in the System Configuration pane shown in Figure 6-9 Figure 6-9 System Configuration Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. PSUs. you can set the IP address. the host communications address and baud rate under Master Slave Protocol. subnet mask.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Configuring Network Parameters In the Network Configuration pane. Figure 6-10 Network Configuration Setting Control Parameters You can set control parameters for the site. PSUs. and the server IP addresses and port number under NetEco. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. Figure 6-10 shows the Network Configuration pane. the trap IP address under SNMP Trap. Ltd 82 . and PDU in the Control pane shown in Figure 6-11. and gateway under System IP. storage batteries. the SNMP version under SNMP. engineer. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-11 Control Managing Users You can create and delete users and modify user information in the User Management pane shown in Figure 6-12. Different user types have different operation rights.. Only admin users have user management rights. Ltd 83 . Users are classified into three types: admin. and operator. select the software and click Activate.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-12 User Management Upgrading Software You can upgrade SMU and PSU software in the Upgrade pane shown in Figure 6-13 To upgrade software. Step 2 After the software information is displayed under Available package active. ----End Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 84 . The software upgrade progress is displayed. A message is displayed when the upgrade is successful.. perform the following steps: Step 1 Click Browse to select the software and then click Send. .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-13 Upgrade Exporting Historical Logs To download configuration files and log files. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. ----End You can export battery testing records in Hypertext Markup Language (HTML) files by clicking Export. The message "Are you sure to download the current configuration file and log file?" is displayed. perform the following steps: Step 1 Click Log History. The configuration files and log files are downloaded in about 2 minutes. Step 2 Click Download under One-click Download. Step 3 Click OK. Figure 6-14 shows the Log History pane. Ltd 85 . TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-14 Log History Exporting Historical Alarms You can download historical alarms in the History Alarms pane shown in Figure 6-15. To export historical alarms in HTML files.. Figure 6-15 Historical Alarms Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 86 . To clear historical alarms. click Clean. click Export. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. and upload configuration files in the Site Configure pane shown in Figure 6-17. site. and Relay in the Alarm Configuration pane shown in Figure 6-16. and save. Figure 6-16 Alarm Configuration Configuring Site Parameters You can set the date. download. Alarm Level. and storage batteries type. time.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Configuring Alarm Parameters You can set Alarm Enable. Ltd 87 .. Ltd 88 . Figure 6-18 Energy Saving Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Control For Different Rates. Daily Electric Consum Mode. Monthly Electric Consum Mode in the Energy Saving pane shown in Figure 6-18.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Figure 6-17 Site Configure Energy Saving You can set Basic Parameters. Control for Exceeding Max Power.. To export electronic label information in HTML files. click Export. Ltd 89 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual 6 Monitoring Function Reading Electronic Labels You can query electronic label information about system components such as the SMU.. Figure 6-19 Electronic Labels Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. power distribution subrack. and PSUs in the Electronic Label pane. N. L2. L3.. PE) 110V dual-live-wire (L1. PE) 220V single-phase three-line (L.300 V AC Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. N. PE) 220V single-phase three-line (L. PE) TP48200T-D20A2 & D14A2:    Input voltage 85V AC . L2. PE) 110V three-phase five-line (L1.8º F) for each additional 200 m (656. N. Ltd 90 .6 ft) to 4000 m (13123. N.2 ft) When the altitude ranges from 2000 m (6561. the operating temperature is derated by 1º C (1.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual A Technical Specifications A Table A-1 Technical specifications Category Environmental conditions Item Operating temperature Storage temperature Transportation temperature Operating humidity Technical Specifications Specifications –10º C to +45º C (14º F to +113º F) –40° C to +70° C (–40° F to +158° F) –40° C to +70° C (–40° F to +158° F) 5%–100% RH 5%–100% RH 0-4000 m (0-13123. N. L3. PE) 110V dual-live-wire (L1. L2.2 ft).16 ft). Storage humidity Altitude AC input Input mode TP48200T-D20A1 & D14A1:    220V three-phase five-line (L1. L2. N. the output resumes. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. L2. L2.99 –42 V DC to –58V DC –53.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual A Technical Specifications Category Item Rated voltage Specifications TP48200T-D20A1 & D14A1:  200-240/346-415V AC for 220V three-phase five-line (L1. L2. PE) 100-120/200-240 V AC for 110V dual-live-wire (L1. PE) 100-120/200-240 V AC for 110V dual-live-wire (L1. PE) 100-127/200-240 V AC for 110V three-phase five-line (L1. L2.. N. N. L3. N. ≤ 1% ≤ 200 mV (0–20 MHz) Overvoltage protection is performed when the single-phase AC input voltage exceeds the AC input overvoltage protection threshold (300 V AC by default). L3. When the voltage is restored to 290 V AC. PE) 200-240 V AC for 220V single-phase three-line (L. N. Ltd 91 . PE) 200-240 V AC for 220V single-phase three-line (L. PE)   TP48200T-D20A2 & D14A2:    Input frequency Rated frequency Power factor DC output Output voltage range Default output voltage Maximum output power Regulated voltage precision Peak-to-peak noise voltage AC input protection AC input overvoltage protection threshold AC input overvoltage recovery threshold AC input undervoltage protection threshold 45–65 Hz 50/60 Hz ≥ 0.5 V DC Number of rectifiers multiplied by the output power of a single rectifier. Undervoltage protection is performed when the single-phase AC input voltage is below the AC input undervoltage protection threshold (85 V AC by default). 0% ≥95. 10 V/m (criterion A) The voltage at signal ports is 3V and power ports is 10 V (criterion A). EMC CE CISPR 22/EN 55022 class B (AC terminal) CISPR 22/EN 55022 class A (DC output terminal) RE Harmonic Fluctuation and blinking ESD CISPR 22/EN 55022 Class B IEC 61000-3-12 IEC 61000-3-3 Contact discharge voltage: 6kV (Class B). air discharge voltage: 15 kV (Class R). and the voltage at the power ports is 2 kV (criterion B).TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual A Technical Specifications Category Item AC input undervoltage recovery threshold Specifications When the voltage is restored to 90 V AC.5 V DC Rectifier (R4850G1) 50A The peak point is ≥96. the rectifier will latch off.If the output voltage is higher than 63 V and lasts for more than 500 ms. Ltd 92 .0%(30%-100% load) Output power Overvoltage protection 3000W 58. the output resumes. Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.5–60. The voltage at the AC power ports in common mode is ± 4 kV (criterion B). air discharge voltage: 8 kV (Class B). The voltage at the AC power ports in differential mode is ± 2 kV.5–60. standard: IEC61000-4-2 EFT RS CS SURGE The voltage at signal ports is 1 kV. 2.5 VDC (can be set by monitoring unit ) 1.. It complies with the IEC61000-4-5 standard.If the overvoltage occurs inside the rectifier due to a fault. DC output protection DC output overvoltage protection threshold Max output current Efficiency 58. Contact discharge voltage: 8kV (Class B). the rectifier will latch off. ) x 700 mm (27. Ltd 93 .56 in.56 in.56 in.) x 700 mm (27..56 in.) x 700 mm (27.000 hours (at 30° C) TP48200T-D20A1 & D20A2:  Cabinet: 2060 mm (81.) x 700 mm (27.56 in.1 in.) Cabinet: 1400 mm (55.1 in.1 in. Nominal discharge current 20 kA Max discharge current 40 kA  For DC power ports.   Equipment compartment is direct-cooling Battery compartment is TEC Cooling capacity TP48200T-D20A1 & D20A2: 1200W TP48200T-D14A1 & D14A2: 800W Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Differential mode: 10 kA Common mode: 20 kA MTBF Structure Dimensions (H x W x D) 200. supporting module-level replacement.56 in.1 in.) Base: 180 mm (7.) x 700 mm (27.) Base: 180 mm (7.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual A Technical Specifications Category Others Item Surge protection Specifications  For AC power ports.56 in.) x 700 mm (27.) x 700 mm (27.)  TP48200T-D14A1 & D14A2:   Weight TP48200T-D20A1 & D20A2: ≤ 200 kg (excluding rectifiers and storage batteries) TP48200T-D14A1 & D14A2: ≤ 160 kg (excluding rectifiers and storage batteries) Protection level Installation Maintenance Cooling IP55 Ground installation From the front.) x 700 mm (27.56 in. Ltd 94 .. Efficiency Peak Power Peak Power Time System Type PSU Summary Total Current Used Capacity AC Voltage AC Total Curr AC Frequency DC Total Power PSU Batt Summ Total Current Pre Disch Time BattChargeSta Fourth-Le vel Menu Default Value - LCD Menu Range - Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual B LCD Menu B Table B-1 LCD Menu Main Menu Active Alarm Running Status Second-Lev el Menu Site Summary Third-Level Menu System Voltage Total Load Ambient Humi 1 Ambient Temp 1 Qty of Battery Sys. 0-60.0 V 45.0 V 35.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual B LCD Menu Main Menu Second-Lev el Menu Third-Level Menu Batt Test Sta Batt Temp 1 Fourth-Le vel Menu Current Capacity Capa Percent Default Value -TP48200T_D1 4A2 58.0 V 53.8 V 0-50 0-3000 A 0-1500 V 100-300 V VRLA Batt VRLA Batt 1 ECC500 GPRS MUC01A_DI_6 GPRS Slot ID GPRS Cur Signal GPRS Status SIM Card Status GPRS IP Address - Alarm History Batt Test Log Settings Alarm Setting Alarm Relay Site Summary PSU Summary PSU Batt Summ VRLA Batt Site Summary System Type DC Over Volt DC Ultra Over V DC Under Volt DC Ultra UnderV Shunt Current Shunt Voltage Qty of Battery AC Over Volt Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.0-47.0 V 43.0 V 300 A 75 mV 1 280 V Range 53.. Ltd 95 .0-60.8 V 35.0-47.0 V 60. 0 -300.80degC 1%-120% Non,Current Limit.Enable 25 .6KW 12H 0H Close Open 15Min 10Min No Disable No Disable 0s 59.80degC -20 -20 degC 0%-100% 0%-100% 25 . start Cap D. Function Diesel Capaciey D. stop Cap Air-Con.0 KW 0.G. Open 1 -60 Min 1-100 Min No.0KW 0. ThreePhase 0-30Min Disable.Smart Ctrl 1 KVA-100 KVA 10-100% 10-100% 0.Enable 0-20s 58.0 KW 6-100H 0-5H Close.Yes Disable.0 -300.5KVA 30% 90% 3. Working E04A_ D (0108)Alm Act Record Interval Alarm Voice Dly Alarm Voice En DST Enable Forbid All Alm Fourth-Le vel Menu - Default Value 180 V Single Phase 10Min Disable 40degC 0degC 80% 10% 50degC 80% Non 12.G.5-60. Open Close.Yes Disable. Ltd 96 .5V PSU Summary Walk-in Enabled Seq Start Intv High Volt Limit Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. StPwr Air-Con.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual B LCD Menu Main Menu Second-Lev el Menu Third-Level Menu AC Under Volt System AC Type AC Fail Time Dial-up Network Amb Hi Temp Pt Amb Low Temp Pt Amb Hi Humi Pt Amb Low Humi Pt Amb V-Hi Temp High Power Pt D. Enable No. WtPwr Max Charge Time Min Charge Time D.5V Range 60-300 V Single Phase..G.G. 01C10 30 Min 16 H Enable 30 Day 9H Range 0-120% 0-120% Disable.5 V 56.05-0.25C10 100Ah 2010-01-01 Enable 0.Enable 48.0-58.50 10-10000 Ah YYYY-MM-DD Enable.Enable Disable. Ltd 97 .05-0.4 V 0.25 0.3 V 0.30 2-1440 Min 50-100% 2-1440 Min 0.30 2-540 Min 5-48 H Enable.05C10 30 Min 80% 10 Min 0..3 V 48. Disable 1-365 Days 1-24 H VRLA Batt Summ Basic Para FC BC Auto BC Enabled To BC Current Curr BC Delay To BC Capacity Capa BC Delay BC to FC Curr BC to FC Delay Max BC Time Cyclic BC Ena Cyclic BC Intv Cyc BC Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.15C10 0.0-58.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual B LCD Menu Main Menu Second-Lev el Menu Third-Level Menu High PSU Cap % Low PSU Cap % Rect Redund Ena Fourth-Le vel Menu Smart Mgmt En Float Charge Boost Charge Current Limit Over Current Rated Capacity Install Date Default Value 20% 100% Disable Disable 53.01-0. Disable 0.01-0. 00 H 0.0-53.Enable No Test.20-50.42 H 1. Ltd 98 .20-50.63 H 1.20-50.05C10 DisTime 0.7C10 Dis Time Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.87 H 0.00 H 0.4C10 Dis Time 0.5C10 Dis Time 0.1C10 Dis Time 0.20-50.00 H 0.0% 5degC 480Min Disable No Test Enable 30 Day 5 Min 80 mV/degC 25degC 20.00H 4.00 H Temp Comp TC Factor Nominal Temp Charge Disch 0.0 V 0.0-100.20-50.20-50.6C10 Dis Time 0.16H 0.00 H 0.20-50.00 H 0. Plan Test Enable.0% -5-15 degC 1-6000 Min Disable.61 H 43..0 V 20.00 H 10.00 H 0.3C10 Dis Time 0.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual B LCD Menu Main Menu Second-Lev el Menu Third-Level Menu Fourth-Le vel Menu Duration Default Value Range Battery Test Test End Volt Test End Capa Test End Temp Test End Time Mains Fail Test Batt Test Type Short Test Ena Short Test Intv ShortT Duration 46.Cyclic Test.Disable 1-360 Days 1-240 Min 0-500 mV/degC 5-45 degC 0.20-50.2C10 Dis Time 0.00 H 0.00 H 2. 19200 Other Batt Temp VHigh Over Temp Volt Batt High Temp Bat V-High Temp Batt Low Temp Batt V-Low Temp 50.0 V Disable .50 H 0.20-50.By Capacity.By Time 35.00 H 0.8 V 37.0-53.42 H 0.35H 95% Lower DC Volt Range 0.BLVD. Disable By Voltage.5 V Disable Normal Close LVD Setting BLVD Enabled BLVD Mode BLVD Voltage BLVD Recon Volt LLVD1 Enabled - ECC500 MUC01A_DI_1 Comm Para Network Mode IP Address Subnet Mask Gateway Host Comm Addr Comm Baudrate - IP 192.20-50.0. Ltd 99 .00 H 60-1005% Lower DC Volt.0.0-47.00 H 0..168.0C10 Dis Time Capacity Coeff Default Value 0.8C10 Dis Time 0.Normal Open 0~31 9600.Enable Normal Close .0 V 25-80 degC 25-80 degC -20-20 degC -20-20 degC Enable.20-50.2 V 51.1 0 9600 Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.9C10 Dis Time 1.0-53.168.10 255.0 192.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual B LCD Menu Main Menu Second-Lev el Menu Third-Level Menu Fourth-Le vel Menu 0.Do Nothing 42.255.5V 45degC 53degC –5degC –10degC Enable By Voltage 43.255. 251.Fault E04A_D(01-08) Smoke 1 Reset Batt Summ BC/FC Ctrl Battery Test Reset Batt Cap Clear Batt Alm Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.33 31220 ENGLISH GMT +08:00 Yes Yes Yes Yes NA 5 Auto Yes No No No Open Yes Float Charge Stop Yes Yes Range Disable. Chinese Auto .159.Enable English .251. Start - System Para LUI Language Set Date Set Time Set Time Zone Save As Def Cfg Restore Def Cfg Restore Manu Cfg Logout Set Site Name Set Batt Type LCD Contrast Control Site Summary Auto/Man Ctrl Network Detect Clear PeakPower Clr ATS Alarm Clr D.33 58..TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual B LCD Menu Main Menu Second-Lev el Menu Third-Level Menu DHCP Phone Number (1-3) Account(1-3) Password NetEco Main IP NetEco Bak IP NetEco Port Fourth-Le vel Menu - Default Value Disable 58.159. Yes Open.G.Manual Yes. Close Float Charge. No No. Ltd 100 . Boost Charge Stop. Start Connect.0~58. Ltd 101 .0 V On.TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual B LCD Menu Main Menu Second-Lev el Menu Third-Level Menu Short Test LLVD1 Control BLVD Control Fourth-Le vel Menu - Default Value Stop Connect 121% 53.2V On Yes Yes Yes 1 100 Ah - Range Stop. Disconnect 1~121% 42.Off 0-50 10 Ah-10000Ah - PSU Summary Current Limit DC Votage Ctrl On/Off Control Reset Clear Rect Lost Clr Phase Fail PSU Clr Alm Hist Quick Settings Qty of Battery Rated Capacity Set Date Set Time IP Address Subnet mask Gateway - Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual C Acronyms and Abbreviations C A AC PDU ASIC ATS D DC PDU Acronyms and Abbreviations Alternating Current Power Distribution Unit Application-Specific Integrated Circuit Automatic Transfer Switch Direct Current Power Distribution Unit E EMS Element Management System I IEC International Electrotechnical Commission L LED LSI Light Emitting Diode Large-scale Integration O OPEX Operational Expenditure P PDU PMU Power Distribution Unit Power Monitoring Unit Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd 102 . Ltd 103 .TP48200T-D20A1 & D20A2 & D14A1 & D14A2 User Manual C Acronyms and Abbreviations S SELV Safety Extra-low Voltage T TCU Temperature Control Unit Issue 01 (2012-06-01) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co..
Copyright © 2024 DOKUMEN.SITE Inc.