Usb-prommer Commissioning Manual en-En

March 20, 2018 | Author: Matius Sasongko | Category: Usb, Electrical Connector, Power Supply, Electromagnetic Interference, Electromagnetic Compatibility


Comments



Description

SIMATICUSB-Prommer Description Edition 10/2007 First Steps in Commissioning Notice indicates that an unintended result or situation can occur if the corresponding notice is not taken into account. Since variance cannot be precluded entirely. Correct. ! ! ! Gefahr indicates that death or severe personal injury will result if proper precautions are not taken. The notices shown below are graded according to the degree of danger. Warnung indicates that death or severe personal injury may result if proper precautions are not taken. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notices in this documentation qualified persons are defined as persons who are authorized to commission. reliable operation of the product requires proper transport. as well as to prevent damage to property. the warning notice representing the highest degree of danger will be used. ground and label devices. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Prescribed Usage Note the following: ! Warnung This device and its components may only be used for the applications described in the catalog or the technical description.Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety. the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. SIEMENS AG Automation and Drives Postfach 4848 90437 NÜRNBERG GERMANY A5E001134243-01 10/2007 Copyright E Siemens AG 2007 Technical data subject to change . Disclaim of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. positioning and assembly as well as careful operation and maintenance. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Caution with a safety alert symbol indicates that minor personal injury can result if proper precautions are not taken. systems and circuits in accordance with established safety practices and standards. storage. However. and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Trademarks All names identified by ® are registered trademarks of the Siemens AG. If more than one degree of danger is present. we cannot guarantee full consistency. notices referring to property damage only have no safety alert symbol. Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Caution without a safety alert symbol indicates that property damage can result if proper precautions are not taken. . . . . . . . . . . . . . . Features and Functions . . . . . . . . . . . . . . . . . . . . 7 Troubleshooting . . . in order to avoid damage to property and personal injury. . . . . . . . . . . . . . . . . . . . . . . . . . 4 Software Installation . . . . . . . . . The SIMATIC USB-Prommer is compatible with USB V1.2 and STEP 7 V5. . . . . . . . . . . . . . . . . . . . . . . . . . . . SIMATIC memory cards and SIMATIC Micro Memory Cards with the corresponding SIMATIC software package. . . . . . . . . . . . • the Windows 98SE. . . . . . . . . . .1+SP2 or later must be installed on the PC. Windows XP. . . . . . the following software requirements must be fulfilled: • the SIMATIC software STEP 5 V7. 3 Hardware Installation . . . . . . . . . . . Description SIMATIC USB-Prommer A5E001134243-01 3 . . . . . . . . . . . . . . . . . . . . . . . . 6 Firmware Update . . . . . . . . . . . Windows Server 2003 Standard Edition or Windows Vista operating system must be installed on the PC. . . . . . . . . . . . . . . . . . . . . . . . . . Windows 2000. . SIMATIC USB-Prommer Features Using the SIMATIC USB Prommer you can read and program both SIMATIC S5 memory cartridges. . . . . 6 Working with the SIMATIC USB-Prommer . . . . . . . . . . . . . . . . . . . . . 10 Certificates. . . . . 11 ! + Warning Always follow the safety instructions in this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Connecting to the PC . . . . . . . . . . . . . . . . .1 and complies with the specifications for a “High-Powered” USB device. . The SIMATIC USB-Prommer supports the power-save mode (hibernate mode). . . . . The notational conventions used to draw your attention to the safety instructions reflect the gravity of the risk involved. . . . . . . . . . . . . . . . . . . . Windows Me. . . . . . 9 Further Support and Sales Information . . . . . . . . . . . . 8 Technical Data . . . . Features and Functions Scope of Delivery With your SIMATIC USB-Prommer you are supplied with the following: • one CD. . Bear in mind that in order to program SIMATIC S5 EPROM modules the SIMATIC S5 programming adapter (included) must be plugged into the PC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The adapter is contained in the scope of delivery. . . . . . . . . . . . . . . . . . .Contents This description guide offers you step by step instructions on how to install and start the SIMATIC USB-Prommer. . . . . . . . containing software and documentation • one SIMATIC S5 programming adapter • one USB cable • one plug-in power supply unit with primary-side adapter for EUROPE and USA • one case Software Requirements To work with the SIMATIC USB-Prommer. . . . . . . . . . . . . . . . . “SIMATIC USB-Prommer”. . . . . . . . . . . Hardware Requirements You need a PC with USB interface and CD ROM drive. . . . Directives and Declarations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . only SIMATIC Micro Memory Cards can be programmed. + Hardware Installation Backplane On the backplane of the device you will find the following connections: • Power supply connector for connection of the plug-in power supply unit. • A USB interface type B for connecting the PC. Power supply USB interface ! Front On the front of the device you will find the following connections: • SIMATIC Micro Memory Card interface: • SIMATIC S5/S7 Memory Card interface: MEM-CARD • Two status LEDs – BUSY – POWER LED Busy LED Power 4 Description SIMATIC USB-Prommer A5E001134243-01 .Function The SIMATIC USB-Prommer has a • a SIMATIC Micro Memory Card interface: • SIMATIC S5/S7 Memory Card interface: MEM-CARD The SIMATIC USB Prommer is connected to the PC via the USB port. The plug-in power supply unit must be used if you want to program S5/S7 Memory Cards or S5 EPROM modules. If the SIMATIC USB-Prommer is used without plug-in power supply unit. either the SIMATIC USB-Prommer is in the power-saving mode (Hibernate mode). The adapter is a push fit on the plug-in power supply unit. The scope of supply includes an adapter for USA and a standard EURO adapter. we cannot guarantee that the prommer will function without errors occurring. and the power supply unit is plugged in. or the PC to which the device is connected is switched off. ! Warning Use only the plug-in power supply unit supplied with the SIMATIC USB-Prommer to connect it to an external power supply. Flashes if a fault occurs. * The Power LED does not turn green until the SIMATIC USB-Prommer is connected to an active PC by means of the USB cable. (Power supply from the USB interface). 3. so that it can be used in countries on either continent. The LEDs do not light up if the USB cable has not been connected to the SIMATIC USB-Prommer and the PC (which must be ON). the SIMATIC USB-Prommer must be powered by the plug-in power supply unit as well (POWER LED turns green). In this mode (without the plug-in power supply unit). 2. If neither the POWER LED nor the BUSY LED lights up even though the USB cable is connected. the SIMATIC USB-Prommer can program only SIMATIC Micro Memory Cards (MMCs). Caution For the operation of the SIMATIC USB-Prommer a power supply with limited performance (USA/Canada: NEC Class 2) is required. The device is supplied complete with a wide-range plug-in power supply unit with adapters for USA socket outlets. If you intend on programming SIMATIC S7 Memory Cards. Connect the power supply unit to your AC 230 V or AC 115 V mains power socket. the green POWER LED on the SIMATIC USB-Prommer lights up. Plug the DC 12 V supply cable from the power supply unit into the DC 12 V power supply connector on the SIMATIC USB-Prommer. (Device is receiving power from the USB interface and the power supply unit). or SIMATIC S5 Memory Cards. If the contacts of the power supply connector are dirty. Connecting the Power Supply Proceed as follows: 1. Power supply The USB cable supolies power from the PC to the SIMATIC USB-Prommer (POWER LED is yellow). POWER green* Power supply unit connected. Flashes if a hardware fault occurs. SIMATIC S5 EPROM modules.LED status indicators Inscription Color Meaning BUSY green Lights up when a programming interface is active. The supplied plug fullfills the requirements. Description SIMATIC USB-Prommer A5E001134243-01 5 . yellow Only USB cable plugged in. Notice When the device is connected correctly. Fit the appropriate power-socket adapter to the plug-in power supply unit. + Connecting to the PC 1. Program the memory module. Plug the USB cable included with the prommer into the USB interface of your PC. Please note the readme file in the root directory on the CD for information on the installation and use of your SIMATIC USB-Prommer software. Setup is menu controlled. the USB cable or the plug-in power supply unit while programming is in progress.+ Software Installation Setup runs the installation of the SIMATIC USB-Prommer software automatically after you insert the CD.exe” to run Setup. 2. you have to open the “Memory Card Parameter Assignment” panel in the Control Panel to set the programming interface to “External prommer” at the connection “USB”. 3. 5. 6 Description SIMATIC USB-Prommer A5E001134243-01 . If the autorun function is disabled. When you use the SIMATIC USB-Prommer for the first time. Make sure that the programming interface of your SIMATIC software in the “Memory Card Parameter Assignment” panel is set to the “External prommer” at the connection “USB”. When you select the “Detect USB prommer automatically” setting. 3. Start the SIMATIC STEP 7 software or the SIMATIC STEP 5 software. Plug the other end of the USB cable into the USB port on the SIMATIC USB-Prommer. Notice While programming is in process the LED BUSY lights up. Open the root directory of this drive. Unplug the memory module from the interface when programming is completed. 6. 4. Do not unplug the memory module. 3. proceed as follows: 1. + Working with the SIMATIC USB-Prommer Requirement: The SIMATIC USB-Prommer is connected to your PC as described above. Connect the plug-in power supply unit as well if you intend programming S5 EPROM modules or S5/S7 Memory Cards. 1. Notice Use only the USB cable provided for the purpose to connect the SIMATIC USB-Prommer to the PC. the SIMATIC USB-Prommer is automatically recognized when connected to the PC. Place the SIMATIC USB-Prommer CD supplied with the product in your PCs CD-ROM drive. 2. Plug the memory medium in question: – Micro Memory Cards to the Micro Memory Card interface – SIMATIC S5/S7 Memory-Cards to the interface MEM-CARD – S5 EPROM/EEPROM modules with the help of the SIMATIC S5 programming adapter to the interface MEM-CARD 2. Double-click “setup. siemens. You will find notes on how to install and use the new firmware there.exe file of the firmware and firmware update tool to your PC. SIMATIC Memory Cards and SIMATIC Micro Memory Cards is not possible. • Download the self-extracting . • Please read the readme file in the firmware update tool catalog. function expansions require modified firmware.! + Warning Simultaneous operation with SIMATIC S5 cartridges. The procedure for updating the firmware is as follows: • The latest firmware updates and the firmware update tool are available in the Internet at the following URL: http://www. If SIMATIC Micro Memory Cards and SIMATIC S5 or S7 Memory Cards are inserted at the same time.com/automation/support&support • Use ”USB Prommer” as your search term in Product Support. Description SIMATIC USB-Prommer A5E001134243-01 7 . the SIMATIC S5/S7 Memory Cards take priority. for example. • Extract the files to a local drive and then update the firmware on your SIMATIC USB-Prommer by following the firmware update tool instructions. Firmware Update The firmware of the SIMATIC USB-Prommer can be updated later if. Power LED does not turn green • USB cable not connected • Connect the USB cable. • Plug-in power supply unit not plugged in or defective. 8 Description SIMATIC USB-Prommer A5E001134243-01 . • PC is switched off • Switch on the PC • PC and SIMATIC USB-Prommer are in power-saving mode (Hibernate mode) • Permissible operating mode • SIMATIC USB-Prommer not recognized by PC • Install driver • SIMATIC Memory Cards and SIMATIC Micro Memory Cards cannot be programmed • Check the version of the SIMATIC STEP 7 software • A hardware fault has occurred • Contact the Customer Support or your Siemens contact person. the device is defective and must be replaced.+ Troubleshooting Some faults are easily rectified as follows: Fault/Cause Remedy Power LED does not turn yellow • USB cable not connected • Connect the USB cable. • If the POWER LED on the device continues to flash after USB cable and power supply unit have been disconnected and reconnected a number of times. • Connect or replace the plug-in power supply unit. Contact the Customer Support or your Siemens contact person. POWER LED flashes continuously • A hardware fault has occurred. Surge symm) ± 2 kV (to IEC 61000-4-5:. power consumption 50/60 Hz (47 to 63 Hz) 15 W Max. Burst. 9 to 500 Hz: acceleration 9. contact discharge (to IEC 61000-4-2) ± 8 kV. Surge asymm) ± 1 kV (to IEC 61000-4-4:. 6ES7792-0AA00-0XA0 Dimensions approx. 80% AM 1kHz (to IEC 61000-4-3) 1 V/m 2 –2. Part 101 or IEC 83/C5 USA plug. 1000 shocks Description SIMATIC USB-Prommer A5E001134243-01 9 . Burst) ± 1 kV (to IEC 61000-4-5:. length > 3m) ± 4 kV. 1. temperature change max.25A Max. temperature change max. 400g DC 12 V.8 m/s tested to DIN IEC 60068–2–27 and DIN IEC 60068–2–29 50 m/s. 10 K/h -20 _C to +60 _C. 100 shocks 250 m/s. 58 to 500 Hz: acceleration 9.7 GHz. current output DC 12 V. power consumption Safety 15 W Protection class Protection class I to VDE 0106 Part 1:(IEC 60536) Safety requirements IEC 60950 equivalent to DIN VDE 0805. DIN IEC 60068-2-30. to ANSI C73.25 A Primary Adapter EURO Primary Adapter USA EURO standard plug to VDE 0620. 172 x 121 x 40 mm Weight Supply voltage approx. equivalent to EN 60950 Safe isolation between line supply and secondary side by plug-in power supply unit Electromagnetic compatibility (EMC) Emitted interference limit class Immunity to line-borne interference on supply lines Immunity on signal lines (on signal lines) Immunity to electrostatic discharge (ESD) Immunity to high-frequency radiation RF current Magnetic field Limit class B to EN55022 ± 2 kV (to IEC 61000-4-4:.5 mm. 6 ms.+ Technical Data Power supply unit Type number FW75550/12 Supply voltage AC 100 – 240 V (+10%. -15%) Frequency of the supply voltage Max. air discharge (to IEC 61000-4-2) 10 V/m 80-1000 MHz and 1.10 or IEC 8/AI-15 SIMATIC USB-Prommer Order no. 80% AM 1kHz (to IEC 61000-4-3) 10 V 10 kHz – 80 MHz 80 % AM 1 kHz (to IEC 61000-4-6) 30 A/m 50 Hz (to IEC 61000-4-8) Ambient conditions Temperature – Operation – Storage/transport Relative humidity – Operation – Storage/transport tested to DIN EN 60068-2-2.075 mm. 1. DIN IEC 60068-2-1. +5 _C to +40 _C.4 – 2 GHz.8 m/s 5 to 9 Hz: amplitude 3. 30 ms. DIN IEC 60068-2-14 5 % to 80 % at 25 _C (no condensation) 5 % to 95 % at 25 _C (no condensation) Mechanical ambient conditions Oscillations (Vibration) – Operation – Storage/transport Shock resistance (shock) – Operation – Storage/transport tested to DIN IEC 60068-2-6 10 to 58 Hz: amplitude 0. length < 3m) ± 2 kV (to IEC 61000-4-4:. Burst. 20 K/h tested to DIN IEC 60068-2-3. please contact your Siemens representative or the SIMATIC Hotline. • The right documents via our Search function in Service & Support.com/automation/service. repairs. • Your local representative for Automation & Drives. • Information on field service.com Training Centers Siemens offers a number of training courses to familiarize you with the SIMATIC S7 automation system.siemens. which constantly provides you with up-to-date information on your products. You will find your contact person at: http://www. spare parts and more under “Services”.com/automation/service&support.com/simatic-tech-doku-portal The online catalog and order system is found under: http://mall. we offer our Know-how online on the internet at: http://www. Telephone: +49 (911) 895-3200 Internet: http://www.siemens. There you will find the following: • The newsletter.siemens.automation.sitrain. where users and experts from all over the world exchange their experiences. • A forum.com Technical Support You can reach the Technical Suport for all A&D products • Via the Web formula for the Support Request http://www.+ Further Support and Sales Information Further Support If you have further questions on how to use the SIMATIC USB-Prommer.siemens.siemens.com/automation/support-request • By e-mail: [email protected] • Phone: + 49 180 5050 222 • Fax: + 49 180 5050 223 Additional information about our Technical Support can be found on the Internet pages: http://www. 10 Description SIMATIC USB-Prommer A5E001134243-01 . Please contact your regional training center or our central training center in D 90327 Nuremberg.siemens.com/automation/partner You will find a guide to the technical documentation offered for the individual SIMATICProducts and Systems here at: http://www. Service & Support on the Internet In addition to our documentation. the EN 61000–3–2:2000 (harmonic currents) and EN 61000-3-3:2001 (voltage fluctuation and flicker) have been fulfilled. the following areas of application are relevant: Application area Requirements Emitted Interference Immunity Domestic. Directives and Declarations Notes on the CE Symbol The following applies to the SIMATIC product described in this description: EMC Directive In accordance with the EU Directive 89/336/EEC “Electromagnetic Compatibility.” In accordance with the CE label for this product. as well as small businesses EN 61000–6–3: 2001 EN 61000–6–1: 2001 Industrial area EN 61000–6–4: 2001 EN 61000–6–2: 2005 In addition.” Conformance with this standard has been verified according to EN 60950–1:2001 +A11:2004. Description SIMATIC USB-Prommer A5E001134243-01 11 . business and commercial areas. Declaration of Conformity The EU declarations of conformity and the relevant documentation are held at the disposal of the competent authorities at the address below: Siemens Aktiengesellschaft Bereich Automation and Drives A&D AS RD ST Type Test Postfach 1963 D-92209 Amberg Germany Phone: +49 9621 80 3283 Fax: +49 9621 80 3278 Observing the Installation Guidelines The installation guidelines and safety instructions specified in this description have to be observed during startup and operation. Connecting I/Os The requirements regarding immunity (EN61000–6–2:2005) are met when you connect a PC suitable for an industrial environment.+ Certificates. Low-Voltage Directive This product complies with the requirements of the EU Directive 2006/95/EEC “Low-Voltage Directive. (I T E) or to UL508 and C22. Canada and Australia Product safety One of the following markings on a device is indicative of the corresponding approval: Underwriters Laboratories (UL) to standard UL 1950 (I.E).2 C22 2 no. Report E11 5352 and Canadian Standard C22. No.T.T.2 C22 2 no. 142 (LR 63533) 12 Description SIMATIC USB-Prommer A5E001134243-01 . no 142 (IND.CONT.2. no 60950–1 (I.2 No.E) or to UL508 (IND.Approvals for the USA.EQ) C US Underwriters Laboratories (UL) to Standard UL 60950–1.CONT.EQ) Canadian Standard Association (CSA) to standard C22. 950 (LR 81690) or to C22. may cause harmful interference to radio communications.EMC USA Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device. if not installed and used in accordance with the instruction manual. Australia This product meets the requirements of the AS/NZS CISPR 22 norm. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Canada Canadian Notice This Class B digital apparatus complies with Canadian ICES-003. Conditions of Operations This device complies with Part 15 of the FCC Rules. pursuant to Part 15 of the FCC Rules. Avis Canadien Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. and (2) this device must accept any interference received. Modifications Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. including interference that may cause undesired operation. Shielded Cables Shielded cables must be used with this equipment to maintain compliance with FCC regulations. and can radiate radio frequency energy and. Operation is subject to the following two conditions: (1) this device may not cause harmful interference. This equipment generates. Description SIMATIC USB-Prommer A5E001134243-01 13 . uses. 14 Description SIMATIC USB-Prommer A5E001134243-01 .
Copyright © 2024 DOKUMEN.SITE Inc.