TSX17 User Manual

March 19, 2018 | Author: Marco Calderon Layme | Category: Cable, Power Supply, Input/Output, Bit Rate, Electrical Engineering


Comments



Description

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 mA supply output for 24 VDC sensors connected to the TSX 17. a 15 V. " ' 9 § é & § 1 8 é ' " 45 3 2 ( 7 6 é 9 & 7 . 1 1.TSX 17B 1428 BATIBUS Micro-PLC . • 14 discrete I/O with front panel status display : . The battery is located in and has a 1 year service life. a 9-pin I/O bus extension connector .2 relay outputs 6 5 E N G L I S H ( 8 7 9 • • • • • a BATIBUS network with front panel status display . 2 removable terminal strips with captive screw terminals. the general instructions for installing the TSX 17B 1428 Micro-PLC are the same as those given in the TSX D11 000E Installation Manual. a ground connector . • a CPU with programming port and status display . • a location for a PL7-2 software cartridge containing the BATIBUS function. 150 mA power supply energizing the BATIBUS network. • a location for a plug-in EEPROM or EPROM memory cartridge for saving user programs. 1 2 3 4 • an internal 24 Kbyte RAM program memory (and 2 Kbytes of data) that can be backed up.Follow-up Sheet Apart from the specific product features indicated on this follow-up sheet.1 Planning the Installation (see Section 1 in TSX D11 000E) Description of TSX 17B 1428 PLC These systems comprise: • a 110/240 VAC power supply that provides a 24 VDC.12 isolated 24 VDC inputs . DATA ON Important The contents of word SW16 can be displayed in 4 digit BCD format by setting SY 14 to state 1 through PL7-2 programming. ON) is no longer active. It thus permits detection of line short-circuits and of a cross-connected module. NET. i.4 in TSX D11 000E Manual) 8 . 2 Mounting • Basic PLC/extension compatibility: as for TSX 172 3428 (see Section 2.1) and of the BATIBUS network (DEF. no acknowledgement or BATIBUS interface problem This LED flashes during transmission or reception This LED comes on when the line is energized by 15 V.e.3 in TSX D11 000E Manual) • overall dimensions: as for TSX 172 3428 (see Section 2. In this case the status display of both outputs (0.2 BATIBUS Network Status Display 0 1 DEF NET DATA ON BUS MD SORTIES OUTPUTS ENTREES E N G L I S H 4 digit readout INPUTS 0 1 2 3 4 5 6 7 8 9 10 11 Contents of SW 16 DEF NET This LED comes on when there is a BATIBUS fault This LED comes on when one of the system components is faulty. DATA.1. The physical layer transmits or receives the coded frames.Follow-up Sheet 3 Wiring (see Section 3 .1 in TSX D11 000E) 24 VDC Input Characteristics: as for TSX 172 3428 Discrete Output Characteristics: relay outputs as for TSX 172 3428 BATIBUS Network Characteristics 5.25 A 24 0V V 0 1 2 3 4 5 6 7 8 9 10 11 E N G L I S H 24 VDC inputs 4 Setting into Service .TSX D11 000E) Power supply 110 to 240VAC ~ + .Maintenance (See Section 4 in TSX D11 000E) 5 5. Line at rest : 15 V (logic state of 0) Pinched line : 0 V (logic state of 1) 9 .+ BUS 0V 0 1 2 3 4 5 6 7 8 9 10 11 0.4 Technical Characteristics Power Supply Characteristics: the same 110/240 V power supply as for TSX 172 3428 (see Section 5.+ or or ~ ~ 24 to 240VAC or 24VDC outputs BATIBUS line powered by internal 15 V Connect shielding to PLC side C N L C 0 0 1 1 110V 240V 50/60Hz + POW 15 V .TSX 17B 1428 BATIBUS Micro-PLC .2 5. Modulation is achieved by pinching off the powered line.1 Principle of Coding/Decoding The modules in the network are powered by 15 V supplied by the TSX 17B 1428 PLC.4.1 5.3 5. 2 µs min.6 V max.4 Recommended Cable • BATIBUS cable (P/N 63715) marketed by Merlin Gerin.2 24.Voltage across line terminals at pinch-off .4. length from processor (or sub-station) to most distant BATIBUS point. 250 nF max.Modulation rate 5. length of overall BATIBUS network.2 max.8 V min. max.Input resistance . at 150 mA 300 mA ± 10% 4000 Vrms 50 pF 5. 6 Service Conditions (see Section 6 in TSX D11 000E) 10 .Line resistance Line voltage drop Line capacitance Spurious capacitance at a point Pinch-off-to-breakdown and breakdown-to-pinch-off switchover times 1. Name BATIBUS BATIBUS BATIBUS I : L : (1) : Area mm2 0.5 V ± 10% 13.75 1. 12 Ω max. 5.3 BATIBUS Line Characteristics E N G L I S H • Transmitter Network .5 2. with 330 mA 50 µA at 18 V 500 K Ω max.5 Special Wiring Precautions Whenever possible keep the BATIBUS cable at least 20 cm away from power cables. otherwise between the conductors and the outside surface of the wire. 50 pF max.5 V max..5.4. between power supply and most distant point 3.Leakage current on line at rest • Receiver Network . with no load on line 4800 bps (bits per second) . isolation between the conductors and the screen or shielding when present.4.2 15. 5 µs max.5 Isolation (1) 4 KV 4 KV 4 KV Type or shielding flexible flexible flexible Screen yes yes yes I m 250 500 600 L m 1900 2500 2500 R/km 46.2 15 V Power Supply Characteristics • • • • • No load voltage Voltage under load Pinch-off current Isolation between mains and bus Capacitance between line and mains 15.4.
Copyright © 2024 DOKUMEN.SITE Inc.