Test Report Iec 60335-2-

March 30, 2018 | Author: Paulo Marchant | Category: Insulator (Electricity), Electrical Wiring, Switch, Ac Power Plugs And Sockets, Force


Comments



Description

Test Report issued under the responsibility ofTEST REPORT IEC 60335-2-2 and/or EN 60335-2-2 Household and similar electrical appliances – Safety – Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances Report reference No. ......................: HZ08020150-001 Date of issue.....................................: 2008-05-30, Amendment 1: 2009-03-06 Content .............................................: 35 pages test report (including 7 pages photographs) Testing Laboratory.........................: Intertek Testing Services Hangzhou Ltd. Address ............................................: 16 No. 1 Ave., Xiasha Economic Development District, Hangzhou 310018, China Applicant’s name............................: Yongkang Zehui Metal Products Co., Ltd. Address ............................................: Wenlou Industrial Area, Gushang Town, Yongkang City, Zhejiang 321308, P. R. China Test specification: th Standard ...........................................: IEC 60335-1:2001 (4 edition), Corr. 1 + A1:2004 + A2:2006, Corr. 1 th IEC 60335-2-2:2002 (5 edition) + A1:2004 + A2:2006 EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 EN 60335-2-2:2003 + A1:2004 + A2:2006 EN62233:2008 Test procedure .................................: GS procedure Non-standard test method…………..: N/A Test Report Form No......................: TTRF_IECEN60335_2_2D2 TRF Originator..................................: Intertek Master TRF.......................................: Dated 2007-09 Copyright © 2006 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ........................: Trade Mark .......................................: Wet/ Dry Vacuum Cleaner RIJING ( ) Manufacturer ...................................: Yongkang Zehui Metal Products Co., Ltd. Model/Type reference.......................: RJC-12-***, RJC-14-*** (***=15L, 20L, 25L, 30L); Ratings .............................................: RJD-12-***, RJD-14-*** (***=15L, 20L, 25L, 30L, 50L, 60L) 220-240V~ 50/60Hz Class II IPX4 RJC-12-*** and RJD-12-***: 1200W; RJC-14-*** and RJD-14-***: 1400W Page 3 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06 Summary of testing: All tests are tested at 50Hz. No difference in performance under 50Hz or 60Hz. RJD-14-15L as the representative subjected to the tests, and the worst results were recorded. From the result of our inspection and tests on the submitted samples, we conclude that they comply with the requirements of the standards. Tests performed (name of test and test clause): Testing location: Clause 7, 8, 10, 11, 13, 15, 16, 19, 20, 21, 22, 23, 29, 30; A13: 2008 of EN 60335-1:2002, Annex EMF Same as previous page. Summary of compliance with National Differences: National differences for Germany have been checked. Copy of marking plate: (Representative) TRF No. TTRF_IECEN60335_2_2D2 .... 3. 19. 8.. "(see Enclosure #)" refers to additional information appended to the report. 11... : Portable and Household use Supply Connection ..... Motor capacitor changed form 0........ Table 10. 2.: Pass (P) .......8. different top enclosure employed and a spiracle with blowing function employed only for D series..Page 4 of 35 Report No..... 16............. Capacity of water tank. Zhejiang 321308.... Yongkang City.........60L... except in full.3.. 13. 16........... 13....25L............ This report shall not be reproduced...1..... 23......... Determination of the test result includes consideration of measurement uncertainty from the test equipment and methods.. Gushang Town. 25L:25l...1... HZ08020150-001....test case does not apply to the test object.....: N/A ..............2.......... New models RJD series added.......... Clause concerned: Clause 7..................test object does meet the requirement ........ EN 50366:2003 updated to EN62233: 2008........ China Amendment 1: The original test report ref. Note: This TRF includes EN Group Differences together with National Differences and Special National Conditions............. without the written approval of the Issuing testing laboratory.......... TTRF_IECEN60335_2_2D2 ..: 2009-02-23 to 2009-02-27 General remarks: The test results presented in this report relate only to the object tested.....1.... 20.2. All models are similarly except the differences as follows: RJ*-**-*** *=C...D.......... 11.... 30.....test object does not meet the requirement . 14: 1400 W rated power and ZH-GS140-P motor........ 21......... Annex EMF. 15............: HZ08020150-001 Amendment 1: 2009-03-06 Test item particulars ........ : Classification of installation and use ........... 16...... 13...15L:15l... 29............ : Without cord reel Possible test case verdicts: ......14........... tests conducted. Ltd....... Factory: Yongkang Zehui Metal Products Co... 29. A13: 2008 of EN 60335-1:2002.......... 29. : Wet & dry pick-up .... 10......50L. (Remark: motor ZH-GS120-P and ZH-GS140-P are the same except different power marked in label) ***=15L.. TRF No...........3..... P..: 2009-02-20 Date (s) of performance of tests . 30L:30l............. 20L:20l......... Address: Wenlou Industrial Area..........2...............................20L...... A13: 2008 of EN 60335-1: 2002 added. Throughout this report a comma is used as the decimal separator. R................ if any.....33µF to 0..... All Differences are located in the Appendix to the main body of this TRF... 12: 1200 W rated power and ZH-GS120-P motor.. dated 2008-05-30........... General product information: Models covered by this report are portable wet & dry pick-up vacuum cleaners for household indoor use only. 50L:50l.. 60L:60l... After review...: Fail (F) Testing .. 4... No...... 24... was modified on 2009-03-06 to include the following additions: 1........ **=12.: Date of receipt of test item ....... : Type Y attachment supply cord .............22µF..... "(see appended table)" refers to a table appended to the report.....................30L........ 22... ..8 Except for type Z attachment............. for the enclosure of electrically-operated water valves in external hose-sets for connection of an appliance to the water mains (IEC 60335-1/A1) N/A Sum of rated power input and the maximum load of the appliance outlet in watts (IEC 60335-2-2) N/A Warning for stationary appliances for multiple supply N/A Warning placed in vicinity of terminal cover N/A Range of rated values marked with the lower and upper limits separated by a hyphen 220-240 Different rated values marked with the values separated by an oblique stroke P P 7.............2 7........... other than IPX0..............marking of protective earthing terminals (symbol 5019 of IEC 60417) N/A TRF No....1 Rated voltage or voltage range (V) ...................: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark 7 MARKING AND INSTRUCTIONS 7...: Refer to marking label P Nature of supply ......................................... TTRF_IECEN60335_2_2D2 ... trademark or identification mark................................................ marked with rated input or rated current for each rated voltage or range...Page 5 of 35 Report No......marking of terminals exclusively for the neutral conductor (N) N/A .....: Refer to marking label P Rated current (A) ....: Refer to marking label P Model or type reference .....................5 Appliances with more than one rated voltage or one or more rated voltage ranges................................: Refer to marking label P Symbol 5172 of IEC 60417...: 7........4 Appliances adjustable for different rated voltages.7 Connection diagram fixed to appliances to be connected to more than two supply conductors and appliances for multiple supply N/A 7..... for Class II appliances Refer to marking label P IP number.....: Refer to marking label P Symbol IEC 60417-5036......6 Correct symbols used P N/A P Motorized cleaning head for water-suction cleaning (symbol 5935 of IEC 60417) (IEC 60335-2-2) N/A 7..........3 Verdict N/A Manufacturer's or responsible vendor's name........... terminals for connection to the supply mains indicated as follows: .......... the voltage setting is clearly discernible N/A 7.... unless N/A the power input is related to the mean value of the rated voltage range Relation between marking for upper and lower limits of rated power input or rated current and voltage is clear 7..........: Refer to marking label P Rated power input (W): ..........: Refer to marking label P Rated frequency (Hz) ......... ............10 Indications of switches on stationary appliances and controls on all appliances by use of figures................. if necessary after removal of a cover P For portable appliances. sensory or mental capabilities........12.............5 Replacement cord instructions...... type Z attachment N/A Instructions and other texts in an official language P Languages ....9 Marking or placing of switches which may cause a hazard 7... or lack of experience and knowledge.... state that the plug must be removed from the socket-outlet before cleaning or maintaining the appliance (IEC 60335-2-2) P 7.......12 Instructions for safe use provided P This appliance is not intended for use by persons (including children) with reduced physical.....Page 6 of 35 Report No......... type Y attachment P Replacement cord instructions........11 Indication for direction of adjustment of controls N/A 7.. type X attachment with a specially prepared cord 7.. TTRF_IECEN60335_2_2D2 .......: 7....... letters or other visual means ..........1 Sufficient details for installation supplied P 7...: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark .. name.marking not placed on removable parts 7...: 7.....13 Replacement cord instructions.......... cover can be removed or opened without a tool N/A For stationary appliances.12..... unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety (IEC 60335-1/A2) P Children should be supervised to ensure that they do not play with the appliance (IEC 60335-1/A2) P Instructions for current-carrying hose (IEC 60335-2-2) N/A Instructions for rotating brushes or similar devices............: Verdict N/A P Marked with Symbol 5007 & 5008 of IEC 60417 P The figure 0 indicates only OFF position... and water-suction cleaning appliances.15 N/A English & German P P N/A Marking on a main part P Marking clearly discernible from the outside...14 Marking clearly legible and durable Height of symbol 5935 of IEC 50417-1 at least 15 mm (mm) (IEC 60335-2-2) .. trademark or identification mark and model or type reference visible after installation N/A TRF No.. unless no confusion with the OFF position N/A 7.... trademark or identification mark and model or type reference visible after installation according to the instructions N/A Indications for switches and controls placed on or near the components.1.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark Verdict For fixed appliances. TTRF_IECEN60335_2_2D2 (IEC 60335-2-2) . rated voltage and normal operation not deviating from rated power input by more than shown in table 1 (see appended table) Suction and blowing function tested separately P The permissible deviations apply for both limits of the range for appliances marked with a rated voltage range having limits differing by more than 10 % of the arithmetic mean value of the range.1 Requirement applies for all positions. Marking not on parts which can be positioned or repositioned in such a way that the marking is misleading P 8 PROTECTION AGAINST ACCESS TO LIVE PARTS 8.1 Power input at normal operating temperature. (IEC 60335-1/A2) N/A Power input of motorized cleaning heads measured separately (IEC 60335-2-2) N/A Booster settings not used N/A TRF No. detachable parts removed P Insertion or removal of lamps.1 Adequate protection against accidental contact with live parts P 8.2 N/A Class II appliances and constructions constructed so that there is adequate protection against accidental contact with basic insulation and metal parts separated from live parts by basic insulation only P Only possible to touch parts separated from live parts by double or reinforced insulation P 10 POWER INPUT AND CURRENT 10. protection against contact with live parts of the lamp cap N/A Use of test probe B of IEC 61032: no contact with live parts 8.Page 7 of 35 Report No. name.2 P Instructions for disconnection before opening (IEC 60335-2-2) N/A Access to live parts prevented by at least basic insulation (IEC 60335-2-2) N/A Use of test probe 13 of IEC 61032 through openings in class 0 appliances and class II appliances/ constructions: no contact with live parts P Test probe 13 also applied through openings in earthed metal enclosures having a non-conductive coating: no contact with live parts 8.1. .: N/A 11.... determined by thermocouples P Temperature rises of windings determined by resistance method.....5 Motor-operated appliances operated under normal operation at most unfavourable voltage between 0...06 times rated voltage ....15 times rated power input ....06 times rated voltage .6 Combined appliances operated under normal operation at most unfavourable voltage between 0......4 Heating appliances operated under normal operation at 1.4V is the most unfavorable............: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark Verdict 11 HEATING 11...1.. suction and blowing function tested separately P Booster settings activated during test as often as allowed (IEC 60335-2-2) ...1 Leakage current not excessive and electric strength adequate TRF No...94 or 1........1 No excessive temperatures in normal use P 11.3 Temperature rises... TTRF_IECEN60335_2_2D2 P P . the test conditions of 3....................94 and 1..8 Appliances incorporating an automatic cord reel are operated first during 30 min with one third of cord unreeled (IEC 60335-2-2) No cord reel and having storge device......: N/A If a suction mode is incorporated in docking stations of automatic battery-powered cleaners.. other than of windings............9 are applied (IEC 60335-2-2/A2) N/A 11...: 254.......1... except N/A components in protective electronic circuits tested for the number of cycles specified in 24.. 50cm of cord unwound Temperature rises not exceeding values in table 3 (see appended tables) N/A P Protective devices do not operate.................06 times rated voltage (IEC 60335-2-2/A2) .....: N/A Docking stations of automatic battery-powered cleaners operated under normal operation at 0....94 and 1.........4 (IEC 60335-1/A1) N/A Sealing compound does not flow out 13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE 13....Page 8 of 35 Report No............7 Operation duration corresponding to the most unfavourable conditions of normal use P Until steady conditions are established (IEC 60335-2-2) P 11.. unless P the windings makes it difficult to make the necessary connections N/A 11.......2 Placing and mounting of appliance as described P 11......: N/A 11.. ....4V N/A Booster settings not used N/A (IEC 60335-2-2) Leakage current measured by means of the circuit described in figure 4 of IEC 60990 P (see appended table) The appliance is disconnected from the supply (IEC 60335-1/A1) Electric strength tests according to table 4 15 MOISTURE RESISTANCE 15...........: Motor-operated appliances and combined appliances supplied at 1...........3 P No trace of water on insulation which can result in a reduction of clearances and creepage distances below values specified in clause 29 P Appliances. followed by the electric strength test of 16..1...1.........1 Enclosure provides the degree of moisture protection according to classification of the appliance 15......... subjected to tests as specified in IEC 60529 ......2 N/A 254.. the base of wall mounted appliances is placed at the same level as the pivot axis of the oscillating tube N/A For IPX4 appliances....: IPX4 P Water valves containing live parts and that are incorporated in external hoses for connection of an appliance to the water mains tested as specified for IPX7 appliances (IEC 60335-1/A1) N/A Hand-held appliance turned continuously through the most unfavourable positions during the test N/A Built-in appliances installed according to the instructions N/A Appliances placed or used on the floor or table placed on a horizontal unperforated support P Appliances normally fixed to a wall and appliances with pins for insertion into socket-outlets are mounted on a wooden board N/A For IPX3 appliances..1....3 Verdict P P IPX4 P Compliance checked as specified in 15.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark Heating appliances operated at 1.. the horizontal centre line of the appliance is aligned with the pivot axis of the oscillating tube N/A TRF No..1....Page 9 of 35 Report No............2..: 13..................2 P P (see appended table) No breakdown during the tests 15......06 times rated voltage.. other than IPX0...15 times rated power input.............1 P Protective impedance and radio interference filters disconnected before carrying out the tests Leakage current measurements 13..... taking into account 15....... TTRF_IECEN60335_2_2D2 .1............. the pivot axis of the oscillating tube located at the level of the underside of the support (IEC 60335-1/A1) N/A For IPX4 appliances.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test However. the movement is limited to two times 90° for a period of 5 min..... the movement of the tube is limited to two times 90° from the vertical for a period of 5 min (IEC 60335-1/A1) N/A Wall-mounted appliances..... for appliances normally used on the floor or table......3 (IEC 60335-2-2) P No trace of liquid on insulation that can result in a reduction of clearances and creepage distances below values specified in clause 29 (IEC 60335-2-2) P Appliances proof against humid conditions P Humidity test for 48 h in a humidity cabinet P The appliance withstands the tests of clause 16 P 16 LEAKAGE CURRENT AND ELECTRIC STRENGTH 16.......3 Verdict P Appliances normally fixed to a ceiling are mounted underneath a horizontal unperforated support..: (IEC 60335-2-2) N/A Additional test for hand-held appliances and other appliances liable to be overturned in normal use (IEC 60335-2-2) P Additional test for water-suction cleaning appliances (IEC 60335-2-2) P The appliance withstands the electric strength test of 16. over a period of 1 min (l) ... take into account the distance to the floor stated in the instructions N/A Appliances with type X attachment fitted with a flexible cord as described N/A Detachable parts tested as specified 15. the support being placed at the level of the pivot axis of the oscillating tube 15.. TTRF_IECEN60335_2_2D2 ..... whichever is most unfavourable (IEC 60335-2-2) N/A Overfilling test with additional amount of water.2 Result – Remark P Spillage of liquid does not affect the electrical insulation in normal use (IEC 60335-2-2) N/A Appliances with type X attachment fitted with a lighest flexible cord as described (IEC 60335-2-2) N/A Appliances incorporating an appliance inlet tested with or without an connector in position.1 Leakage current not excessive and electric strength adequate P Protective impedance disconnected from live parts before carrying out the tests N/A TRF No.Page 10 of 35 Report No... ...06 times rated voltage divided by √3....electric strength test 3000 V N/A 19 ABNORMAL OPERATION 19.........electric strength test 2000 V N/A ....2 Single-phase appliances: test voltage 1.102 (IEC 60335-2-2) N/A Centrally-sited vacuum cleaners also subjected to tests of Cl.. windings and connections have not worked loose (IEC 60335-2-2) P During the tests the appliance does not emit flames........ rotating brushers and similar devices being removed (IEC 60335-2-2) 312V P Safety not impaired.103....10 19........: 16.. and 19...... molten metal.7 (IEC 60335-2-2/A1) N/A Water-suction cleaning appliances with a valve also subjected to test of Cl...... 19.........1 The risk of fire or mechanical damage under abnormal or careless operation obviated P Electronic circuits so designed and applied that a fault will not render the appliance unsafe N/A Appliances incorporating contactors or relays are subjected to the test of 19.....Page 11 of 35 Report No.3 Verdict P N/A Leakage current measurements (see appended table) P Electric strength tests according to table 7 (see appended table) P No breakdown during the tests P Tests for current-carrying hoses immersed for 1 h (IEC 60335-2-2) N/A ......3 times rated voltage for 30 s with the air inlet blocked. TTRF_IECEN60335_2_2D2 ...........4V voltage..06 times rated 254..... poisonous or ignitable gas in hazardous amounts P Temperature rises not exceeding the values shown in table 9 (see appended table) N/A Compliance with cl.... (IEC 60335-1/A2) N/A Only motorized cleaning heads and separate fan motors of centrally-sited vacuum cleaners subjected to the test of Cl.......104 as applicable (IEC 60335-2-2) N/A Series motors operated at 1.....13 Appliances with a booster setting not deactivated electronically also subjected to test of Cl 19.......: Three-phase appliances: test voltage 1.2 P TRF No.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark 16.... 19...14.101 (IEC 60335-2-2) P 19...... 19. 8 not impaired (IEC 60335-1/A2) P If the appliance can still be operated it complies with 20.... being twice the working voltage (IEC 60335-1/A2) N/A The appliance shall not undergo a dangerous malfunction (IEC 60335-1/A1) P There shall be no failure of protective electronic circuits if the appliance is still operable (IEC 60335-1/A1) N/A Appliances tested with an electronic switch in the off position.supplementary insulation .. TTRF_IECEN60335_2_2D2 N/A P .. appliance does not overturn 20.basic insulation.. or (IEC 60335-1/A2) N/A – if they become operational.. the test voltage specified in table 4: .... withstand the electric strength test of 16.........3................. : 3000V P After the operation or interruption of a control. however.... by unexpected reclosure Not possible to touch dangerous moving parts with test probe TRF No.. the test voltage........ not result in a dangerous malfunction during or after the tests of 19........ or in the stand-by mode. other than of class III appliance......... guards and similar parts are non-detachable P Adequate mechanical strength and fixing of protective enclosures P Self-resetting thermal cut-outs and overcurrent protective devices not causing a hazard...............Page 12 of 35 Report No.. P Tilting test repeated on appliances with heating elements... : 1000V P .3..........2 N/A P P tank with or without water tested separately.. temperature rise does not exceed values shown in table 9 N/A Moving parts adequately arranged or enclosed as to provide protection against personal injury P Protective enclosures... angle of inclination increased to 15° N/A Possible heating test in overturned position.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark Verdict Insulation.......101 Operation of water-suction cleaning appliances as specified (IEC 60335-2-2) 20 STABILITY AND MECHANICAL HAZARDS 20.11..........reinforced insulation ..4. shall (IEC 60335-1/A2) – not become operational....... (IEC 60335-1/A2) 19............... RJD-14-50L and RJD-14-60 tested.. : 1750V P ........ clearances and creepage distances across the functional insulation shall withstand the electric strength test of 16...1 Adequate stability Tilting test through an angle of 10° (appliance placed on an inclined plane/horizontal plane). commutators and slip rings not exposed to oil.7 Adequate safeguards against the risk of excessive pressure in appliances provided with steam-producing devices N/A 22.5 No risk of electric shock when touching the pins of the plug P The appliance is supplied at rated voltage. One second after disconnection.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test 21 MECHANICAL STRENGTH 21. TTRF_IECEN60335_2_2D2 .1 Appliance has adequate mechanical strength and is constructed as to withstand rough handling P No damage after three blows applied to various parts of the enclosure. grease or similar substances P Adequate insulating properties of oil or grease to which insulation is exposed N/A TRF No.2 Result – Remark The insulation is tested as specified.8 Electrical connections not subject to pulling during cleaning of compartments to which access can be gained without the aid of a tool. windings. the voltage between the pins of the plug is measured with an instrument that does not appreciably affect the value to be measured (IEC 60335-1/A1) P The voltage shall not exceed 34 V (IEC 60335-1/A1) 22.3 N/A If necessary.5 ± 0.Page 13 of 35 Report No.6 Max. Any switch is then placed in the off position and the appliance is disconnected from the supply mains at the instant of voltage peak.04 J P If necessary. impact energy 0. unless (IEC 60335-1/A1) Verdict N/A the thickness of supplementary insulation is at least 1 mm and reinforced insulation is at least 2 mm (IEC 60335-1/A1) P 22 CONSTRUCTION 22. 5V P Electrical insulation not affected by condensing water or leaking liquid P Electrical insulation of Class II appliances not affected in case of a hose rupture or seal leak P 22. internal wiring. repetition of groups of three blows on a new sample N/A Accessible parts of solid insulation having strength to prevent penetration by sharp implements (IEC 60335-1/A1) P 21. supplementary or reinforced insulation subjected to the electric strength test of 16. and that are likely to be cleaned in normal use P 22.9 Insulation. 22 Appliances not containing asbestos 22.15 Storage hooks and the like for flexible cords smooth and well rounded P 22. moisture or contact with moving parts P Obvious locked position of snap-in devices used for fixing such parts P No deterioration of the fixing properties of snap-in devices used in parts that are likely to be removed during installation or servicing N/A Tests as described 22. the shape being so that an axial pull is likely to be applied Handle P 22. liable to be touched by the user in normal use or during user maintenance P 22.14 No ragged or sharp edges creating a hazard for the user in normal use.26 The insulation between parts operating at safety extralow voltage and other live parts complies with the requirements for double or reinforced insulation TRF No.13 Unlikely that handles. knobs etc. fixed in a reliable manner P Fixing in wrong position of handles. cotton.11 Reliable fixing of non-detachable parts that provide the necessary degree of protection against electric shock.18 Current-carrying parts and other metal parts resistant to corrosion under normal conditions of use P 22. TTRF_IECEN60335_2_2D2 N/A P No oil P P .. silk. when gripped as in normal use. indicating position of switches or similar components not possible P Axial force 15 N applied to parts.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test 22. or during user maintenance P No exposed pointed ends of self tapping screws etc. knobs etc. ordinary paper and fibrous or hygroscopic material not used as insulation.12 Result – Remark 50N push and pull force applied to enclosure.21 Wood.23 Oils containing polychlorinated biphenyl (PCB) not used 22. unless impregnated P This requirement does not apply to magnesium oxide and mineral ceramic fibres used for the electrical insulation of heating elements (IEC 60335-1/A2) 22. 50N push and 30N pull force applied to switch cover Verdict P Handles.Page 14 of 35 Report No. the shape being so that an axial pull is unlikely to be applied Switch cover P Axial force 30 N applied to parts. handle. make the operators hand touch parts having a temperature rise exceeding the value specified for handles which are held for short periods only P 22. screws etc.28 Metal parts of Class II appliances conductively connected to gas pipes or in contact with water: separated from live parts by double or reinforced insulation P 22. not in direct contact with basic or reinforced insulation P For class II constructions.2 (IEC 60335-2-2) P Conductive liquids that are or may become accessible in normal use are not in direct contact with live parts P Electrodes not used for heating liquids N/A For class II constructions.30 Parts serving as supplementary or reinforced insulation fixed so that they cannot be removed without being seriously damaged.33 Result – Remark Verdict Supplementary insulation of natural or synthetic rubber resistant to ageing. conductive liquids that are or may become accessible in normal use. conductive liquids which are in contact with live parts.Page 15 of 35 Report No. becomes loose P Supplementary and reinforced insulation designed or protected against deposition of dirt or dust P 22. not in direct contact with reinforced insulation N/A TRF No. (IEC 60335-1/A2) N/A Oxygen bomb test at 70 °C for 96 h and 16 h at room temperature N/A Vacuum cleaners constructed so that internal parts of motors and electrical connections protected against deposition of dust due to passage of air (IEC 60335-2-2) P Water-suction cleaning appliances checked by test of 15. TTRF_IECEN60335_2_2D2 . or arranged and dimensioned so that creepage distances are not reduced below values specified in 29.32 22.2 N/A Ceramic material not tightly sintered. or P so constructed that they cannot be replaced in an incorrect position. and so that if they are omitted. similar material or beads alone not used as supplementary or reinforced insulation N/A Insulating material in which heating conductors are embedded is considered to be basic insulation and not reinforced insulation.31 22.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test 22. the appliance is rendered inoperable or manifestly incomplete P Clearances and creepage distances over supplementary and reinforced insulation not reduced below values specified as a result of wear P Creepage distances and clearances between live parts and accessible parts not reduced below the values specified for supplementary insulation if wires. they shall be adequately covered by insulating material or their accessible parts shall be separated from their shafts or fixings by supplementary insulation. The actuating member of this switch shall be easily visible and accessible.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark Verdict 22. handles.42 P Metal casings of capacitors in Class II appliances separated from accessible metal parts by supplementary insulation.Page 16 of 35 Report No.4 due to deformation as a result of an external force applied to the enclosure P TRF No.45 When air is used as reinforced insulation. unless complying with 22.1. (IEC 60335-1/A2) N/A 22. or having accessible moving parts. or separated from live parts by earthed metal N/A 22. handles.37 Capacitors in Class II appliances not connected to accessible metal parts.40 Motor-operated appliances and combined appliances intended to be moved while in operation. levers etc. unless the shaft is not accessible when the part is removed P 22. levers and knobs on stationary appliances other than those of electrical components. The actuating member of the switch being easily visible and accessible P Unless the appliance can operate continuously.36 Handles continuously held in the hand in normal use are so constructed that when gripped as in normal use. automatically or remotely without giving rise to a hazard.38 Capacitors not connected between the contacts of a thermal cut-out N/A 22. the operators hand is not likely to touch metal parts.44 Appliances shall not have an enclosure that is shaped or decorated like a toy (IEC 60335-1/A2) P 22. provided they are either reliably connected to an earthing terminal or earthing contact. other than lamps.41 No components. (IEC 60335-1/A2) N/A This requirement does not apply to handles. TTRF_IECEN60335_2_2D2 . unless they are separated from live parts by double or reinforced insulation P 22. levers and knobs that are held or actuated in normal use shall not become live in the event of a failure of basic insulation (IEC 60335-1/A2) P If these handles. not live. appliances for remote operation shall be fitted with a switch for stopping the operation of the appliance.34 Shafts of operating knobs. clearances not reduced below the values specified in 29. levers and knobs are of metal and if their shafts or fixings are likely to become live in the event of a failure of basic insulation. fitted with a switch to control the motor.42 N/A 22. unless complying with 22. containing mercury P 22.35 For constructions other than those of class III. unless No aluminium wires 29. if the construction is affected by wear. creepage distances and solid insulation withstand electrical stress P For coatings used on printed circuits boards to protect the microenvironment (Type 1) or to provide basic insulation (Type 2). unless (see appended table) P for basic insulation and functional insulation they comply with the impulse voltage test of clause 14 (IEC 60335-1/A1) N/A However. CREEPAGE DISTANCES AND SOLID INSULATION Clearances.Page 17 of 35 Report No.8 Aluminium wires not used for internal wiring 23.1 P P clamping means so constructed that there is no risk of bad contact due to cold flow of the solder 29 Verdict N/A CLEARANCES. movement of the parts or during assembly. P Wire holes in metal well rounded or provided with bushings 23.when the microenvironment is pollution degree 3 .9 No lead-tin soldering of stranded conductors where they are subject to contact pressure.1 Wireways smooth and free from sharp edges P Wires protected against contact with burrs.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause Requirement – Test Result – Remark 23 INTERNAL WIRING 23. distortion. the clearances for rated impulse voltages of 1500V and above are increased by 0. taking into account the rated impulse voltage for the overvoltage categories of table 15. cooling fins etc.5 mm and the impulse voltage test is not applicable (IEC 60335-1/A1) P Impulse voltage test not applicable: . annex J applies (IEC 60335-1/A2) N/A The microenvironment is pollution degree 1 under Type 1 coating (IEC 60335-1/A2) N/A No creepage distance or clearance requirements under Type 2 coating (IEC 60335-1/A2) N/A Clearances not less than the values specified in table 16.for basic insulation of class 0 and class 01 appliances Appliances are in overvoltage category II TRF No.5 N/A Wiring effectively prevented from coming into contact with moving parts P The insulation of internal wiring withstanding the electrical stress likely to occur in normal use P No breakdown when a voltage of 2000 V is applied for 15 min between the conductor and metal foil wrapped around the insulation P 23. TTRF_IECEN60335_2_2D2 (IEC 60335-1/A1) P N/A P . taking into account the rated impulse voltage P Clearance at the terminals of tubular sheathed heating elements may be reduced to 1mm if the microenvironment is pollution degree 1 N/A Lacquered conductors of windings considered to be bare conductors (IEC 60335-1/A1) P 29. clearances of basic insulation on the secondary side not less than those specified in table 16.2 Clearances of supplementary insulation not less than those specified for basic insulation in table 16 P 29. pollution degree 1 N/A TRF No. unless P the appliance complies with clause 19 with the functional insulation short-circuited 29. but using the next higher step for rated impulse voltage P 29. but using the next lower step for rated impulse voltage N/A Circuits supplied with a voltage lower than rated voltage. or if there is an earthed screen between the primary and secondary windings. the voltage used for determining clearances from table 16 is the sum of the rated impulse voltage and the difference between the peak value of the working voltage and the peak value of the rated voltage N/A If the secondary winding of a step-down transformer is earthed.5 29.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause 29.2 N/A Lacquered conductors of windings considered to be bare conductors (IEC 60335-1/A1) P However.1 Requirement – Test Result – Remark Verdict Compliance is checked by inspection and measurements as specified P Clearances of basic insulation withstand the overvoltages.1. taking into account the material group and the pollution degree P Pollution degree 2 applies. the values of table 16 are applicable.1.1. clearances of functional insulation based on the working voltage used as the rated voltage in table 15 N/A Creepage distances not less than those appropriate for the working voltage. unless N/A precautions taken to protect the insulation.4 For functional insulation.Page 18 of 35 Report No. clearances at crossover points are not measured (IEC 60335-1/A1) P Clearance between surfaces of PTC heating elements may be reduced to 1mm N/A Appliances having higher working voltage than rated voltage. TTRF_IECEN60335_2_2D2 .1.1.3 Clearances of reinforced insulation not less than those specified for basic insulation in table 16. to withstand the electrical stresses (IEC 60335-1/A1) P Compliance checked by: (IEC 60335-1/A1) .3.1 P P . in accordance with 29. or N/A .3 (see appended table) Creepage distances may be reduced if the appliance complies with clause 19 with the functional insulation short-circuited N/A Supplementary and reinforced insulation having adequate thickness. or a sufficient number of layers.4 Creepage distances of functional insulation not less than specified in table 18 29.1.an assessment of the thermal quality of the material combined with an electric strength test.3.3 Creepage distances of reinforced insulation at least double as specified for basic insulation in table 17 P 29. in accordance with 29.2. <10% Refer to:HZ09020276-EMF01 TRF No.: HZ08020150-001 Amendment 1: 2009-03-06 IEC/EN 60335-2-2 Clause 29.1 Requirement – Test Result – Remark Verdict insulation subjected to conductive pollution.2 Creepage distances of supplementary insulation at least as specified for basic insulation in table 17 P 29.3. pollution degree 3 P Compliance is checked by inspection and measurements as specified P Creepage distances of basic insulation not less than specified in table 17 (see appended table) For pollution degree 1.2.2.measurement.Page 19 of 35 Report No. if the clearance has been checked according to the test of clause 14 P N/A 29.2. creepage distance not less than the minimum specified for the clearance in table 16.an electric strength test in accordance with 29.3 N/A Supplementary insulation having a thickness of at least 1 mm (IEC 60335-1/A1) P Reinforced insulation having a thickness of at least 2 mm (IEC 60335-1/A1) P ANNEX EMF The Tested product also complies to the requirements of EN62233:2008 Limit ……………100% Measured max.2. TTRF_IECEN60335_2_2D2 P . or 29.3. Subclause 6. TRF No.7 (Replacement:) If the remote operation of the appliance is via a telecommunication network.1. the relevant standards for the telecommunication interface circuitry in the appliance are EN 41003 and EN 60950-1:2006.: HZ08020150-001 Amendment 1: 2009-03-06 ANNEX EN 60335-1:2002/ A13: 2008 Clause Requirement ─ Test 24 Components 24.Page 20 of 35 Report No.3. TTRF_IECEN60335_2_2D2 Result ─ Remark Verdict — N/A . ......6% +15% P Pi= 1095 1400 Pm=1166 Suction function RJD-12-*** (***=15L..........8% +15% P -17.....50L.....8a TABLE: Heating test....20L.60L) 1200 Blowing function RJD-14-*** (***=15L......... thermocouples (RJD-14-15L suction function) P Test voltage (V) ........30L............: 254....286 2..20L...50L......60L) P P measured (W) Pf= 1237 dP Required dP Remark -2..25L....25L........Page 21 of 35 10...............50L.60L) P rated (W) 1200 Suction function RJD-14-*** (***=15L......7% +15% P -3......: 254.098 62 90 Class 120 Rotor(7pcs) 2......30L.8% +15% P -16...: 23 ⎯ Thermocouple locations dT (K) Max.....: 23 ⎯ Temperature rise of winding R1 (Ω) R2 (Ω) dT (K) Max....... resistance method (RJD-14-15L suction function) P Test voltage (V) .......................30L.....................20L..901 69 90 Class 120 TRF No.... t2 (°C) ........60L) Pf= 1227 Pi= 1081 1400 Pm=1154 Blowing function All above tests tested at 230V~ 50Hz 11.25L.......4 ⎯ Ambient (°C) .... dT (K) Supply cord 4 50 Ambient of switch 13 60(T85) Switch surface 7 60 Internal wire 41 80(T105) Handle 11 50 Capacitor 14 60(T85) Internal enclosure(top) 16 - Internal enclosure(air outlet) 35 - Enclosure (external) 10 60 Wood support 1 65 Wire connector 13 - 11.....25L. t1 (°C) .......: 23 ⎯ Ambient.....: HZ08020150-001 Amendment 1: 2009-03-06 TABLE: Power input deviation Input deviation of/at: RJD-12-*** (***=15L.....1 Report No......8a TABLE: Heating test........ dT (K) Insulation class Stator 1..........50L....20L. TTRF_IECEN60335_2_2D2 .................................30L.............689 2............4 ⎯ Ambient......... ....8b TABLE: Heating test...........: 254............286 2................ dT (K) Insulation class Stator 1.....: 23 ⎯ Temperature rise of winding R1 (Ω) R2 (Ω) dT (K) Max.....................889 68 90 Class 120 13.......................: 254....: N/A ⎯ Motor-operated and combined appliances: 1........8b Report No... TTRF_IECEN60335_2_2D2 ...................4 ⎯ Ambient (°C) . thermocouples (RJD-14-15L blowing function) P Test voltage (V) .............012 0......: 23 ⎯ Thermocouple locations dT (K) Max......3 TABLE: Electric strength Test voltage applied between: P Voltage (V) Breakdown (Yes/No) Parts over basic insulation 1000 No Parts over supplementary insulation 1750 No Parts over reinforced insulation 3000 No TRF No.......092 61 90 Class 120 Rotor(7pcs) 2......................................25 L/N and knobs Max: 0......................... t2 (°C) .................012 0.................: HZ08020150-001 Amendment 1: 2009-03-06 TABLE: Heating test. dT (K) Supply cord 4 50 Ambient of switch 10 60(T85) Switch surface 6 60 Internal wire 37 80(T105) Handle 7 50 Capacitor 11 60(T85) Internal enclosure(top) 14 - Internal enclosure(air outlet) 29 - Enclosure (external) 9 60 Wood support 1 65 Wire connector 13 - 11.....................2 TABLE: Leakage current P Heating appliances: 1.................... allowed I (mA) L/N and enclosure Max: 0.....4 ⎯ Ambient.Page 22 of 35 11.....25 13.....15 x rated input . resistance method (RJD-14-15L blowing function) P Test voltage (V) ..689 2......: 254................4V ⎯ Leakage current between I (mA) Max........... t1 (°C) .: 23 ⎯ Ambient.................06 x rated voltage............ ......... allowed I (mA) Live parts and enclosure Max: 0...: N/A ⎯ Leakage current between I (mA) Max.4V ⎯ Three phase appliances 1.. TTRF_IECEN60335_2_2D2 ............06 x rated voltage ......016 0..25 Live parts and knobs Max: 0........25 16.........: 254..06 x rated voltage divided by √3: .016 0......: HZ08020150-001 Amendment 1: 2009-03-06 TABLE: Leakage current P Single phase appliances: 1....3 TABLE: Electric strength Test voltage applied between: P Voltage (V) Breakdown (Yes/No) Parts over basic insulation 1250 No Parts over supplementary insulation 1750 No Parts over reinforced insulation 3000 No TRF No.2 Report No.Page 23 of 35 16......... Thickness: 1. Ltd. KND2-14/2 250V~ 14(12)A T85 5E4 IP54 EN 61058-1: 1992+A1 TUV/R 50105402 Alternative SHANGHAI QIJIA R11-8 ELECTRONIC CO.75 or 1. EN 60335-2-2 ZEK 01. EN 60335-2-2 Tested with appliance Brush holder Tube Yongkang Zehui Metal PF EN 60335-2-2 Tested with appliance Sinopec Shanghai Petrochemical Company Limited PP Thickness: 1. MPX/MKP 275V~ X2 0. Ltd.0mm 2 DIN VDE 0281-5: 2002 VDE/ 40007592 Alternative Ningbo Qiaopu Electric Co..Ltd. trademark Type / model Technical data Standard Mark(s) of 1) conformity Power plug FRIENDSHIP ENTERPRISES INTERNATIONAL LTD... LTD.22µF 40/100/21/C IEC60384-14 2nd edition: 95 VDE/ 119119 Internal wire Shanghai Plastic Wire Factory 1015 600V 18AWG EN 60335-2-2 T105(UL E109819) Tested with appliance Alternative Shanghai Shangxu Wire & Cable Co. FE-02P 250V~ 16A DIN 49406-R DIN VDE 0620-1: 2002 VDE/ 40007128 Alternative Ningbo Qiaopu Electric Co.. Ltd. CHS3 PA66 Min..LTD.22µF 40/085/21/C DIN VDE 0620-1: 2005 TUV/R 50111334 Alternative AID EIECTRONICS CORPORATION MEX 275V~ X2 0. ZH-GS140-P 220/230/240V~ 50/60Hz 1400W. MEX 275V~ X2 0. Ltd. H05VV-F 2 x0.0mm min. ZH-GS120-P 220/230/240V~ 50/60Hz 1200W. LTD.2 -08 Tested with appliance TRF No. H05VV-F 2 x0. Black.5mm min. Class120 EN 60335-2-2 Tested with appliance Top and bottom enclosure Sinopec Shanghai Petrochemical Compan Limited PP T300 Thickness: 1.. 1015 600V 18AWG EN 60335-2-2 T105(UL E225292) Tested with appliance Alternative Yuyao Donghai Special Wire Factory 1015 600V 18AWG EN 60335-2-2 T105(UL E212811) Tested with appliance Wire connector Changhong Plastic Co. Hard.75 or 1. thickness: 0.75 or 1. Class120 EN 60335-2-2 Tested with appliance Motor for RJC/D-12 series Yongkang Zehui Metal Products Co. Ltd.6mm EN 60335-2-2 Tested with appliance Motor for RJC/D-14 series Yongkang Zehui Metal Products Co.0mm 2 DIN VDE 0281-5: 2002 VDE* Switch Yueqing Jiaben Electronics Co.0mm 2 DIN VDE 0281-5: 2002 VDE/ 136970 Alternative Various H05VV-F 2 x0..1 Report No.5mm min. 250V~ 16(8)A T125 10E3 IP50 EN 61058-1: 2002 VDE/ 40022038 Capacitor CHANGZHOU DEFU ELECTRIC CO.Page 24 of 35 24.. Ltd.: HZ08020150-001 Amendment 1: 2009-03-06 TABLE: Components P Object / part Manufacturer/ No. TTRF_IECEN60335_2_2D2 . D02 250V~ 16A DIN 49406-R DIN VDE 0620-1: 2002 VDE/ 40002875 Alternative Various Various 250V~ 16A DIN 49406-R DIN VDE 0620-1: 2005 VDE* Power cord FRIENDSHIP ENTERPRISES INTERNATIONAL LTD.22µF 40/085/21/C IEC 60384-14 2nd edition: 95 VDE/ 094710 Alternative TENTA ELECTRIC INDUSTRIAL CO. 8 2. : ⎯ II Type of insulation: Rated impulse voltage (V): Min.2 0. EVA Standard Mark(s) of 1) conformity EN 60335-2-2 ZEK 01.5 1.4 ⎯ >50 and ≤ 125 0.9 1. Flexible hose Manufacturer/ trademark Zhejiang Panan Jiangshan Sida Type / model Technical data Handle Yongkang Zehui metal products Metal Silver.4 >50 and ≤ 125 0.2 -08 Tested with appliance EN 60335-2-2 ZEK 01.0mm min.2 1.Page 25 of 35 24.6 4.5 ⎯ ⎯ ⎯ ⎯ N/A 500 0.8 2.2 1.8 1.0 X X X ⎯ P 4 000 3.2 0.2 1. Thickness: 0. 2)“Various“ means any type from any manufacturer that complies with the specification can be used.1 TABLE: Clearances P Overvoltage category. TTRF_IECEN60335_2_2D2 ⎯ ⎯ N/A ⎯ N/A ⎯ N/A N/A .3 1.7 1.2 TABLE: Creepage distances.6 2.6 1.5 3.5 ⎯ ⎯ ⎯ X P 6 000 6.9 ⎯ ≤ 50 0.0 ⎯ ⎯ ⎯ ⎯ N/A 8 000 8.4 1.3 1.0 X ⎯ ⎯ P >125 and ≤ 250 0.9 1.2 3.8 2.8 ⎯ >50 and ≤ 125 0.7 1.0 3. Thickness:2.2mm min. Soft.1 Report No. Black.5 ⎯ ⎯ ⎯ ⎯ N/A 1 500 0..1 1. Hard.3 0.1 2.9 ≤ 50 0.1 1.0 3.6 0.6 4.9 2.6 0.4 3.2 4.5 ⎯ ⎯ ⎯ ⎯ N/A 800 0.2 -08 Tested with appliance 1)An asterisk indicates a mark which assures the agreed level of surveillance.1 2.: HZ08020150-001 Amendment 1: 2009-03-06 TABLE: Components P Object / part No.3 0.6 1.8 4.2 3.5 ⎯ ⎯ ⎯ ⎯ N/A 2 500 2.5 ⎯ ⎯ ⎯ ⎯ N/A 29.5 1.5 ⎯ ⎯ ⎯ ⎯ N/A 10 000 11.8 ⎯ ⎯ >125 and ≤ 250 0.5 1.2 3. basic.4 3.8 1.5 1. supplementary and reinforced insulation Working voltage (V) P Creepage distance (mm) Pollution degree 1 2 3 Material group Material group I II IIIa/IIIb I II Type of insulation IIIa/IIIb ) B* S* ) R* ) Verdict ⎯ ⎯ N/A ⎯ N/A ≤ 50 0. 29. cl (mm) Basic Functional Supplementary Reinforced Verdict / Remark 330 0.6 1.0 ⎯ X ⎯ P TRF No.9 2.5 3.. 0 12.0 40.1 10.2 16.0 14.0 25.0 36.8 4.0 7.4 12.2 4.2 6.0 25.0 ⎯ >500 and ≤ 800 3.0 ⎯ >3200 and ≤ 4000 25.0 TRF No.4 9.0 20.0 22.0 22.3 9.6 6.0 ⎯ >1250 and ≤ 1600 8.0 20.0 10.8 3.5 10.0 ⎯ >1600 and ≤ 2000 11.0 9.0 ⎯ >2500 and ≤ 3200 20.0 5. 0 28.0 20.0 ⎯ >2000 and ≤ 2500 15.0 >2000 and ≤ 2500 7.0 63.2 20.0 6.5 6.0 10.4 4.0 40.0 20.2 Report No.0 ⎯ >1250 and ≤ 1600 4.5 14.0 56.2 16.0 40.6 6.0 10.6 16.0 25.0 7.5 >800 and ≤ 1000 2.0 6.0 5.6 8.0 >1000 and ≤ 1250 3.0 28.5 18.0 44.0 20.0 22.0 5.0 5.0 50.6 8.0 22.0 50.3 7.6 5.0 14.0 ⎯ >800 and ≤ 1000 2.6 3.0 25.5 16.2 5.6 8.0 90.5 14.0 45.0 50.4 4.0 64.0 28.5 3.0 11.0 25.6 5.1 8.0 32.0 14.0 80.0 7.6 5.6 18.0 16.0 12.0 32. TTRF_IECEN60335_2_2D2 ) ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A .0 5.5 6.0 2.Page 26 of 35 29.2 2.5 16.: HZ08020150-001 Amendment 1: 2009-03-06 TABLE: Creepage distances.0 32.0 40.3 8.3 9.4 7.2 16.0 11.0 ⎯ >3200 and ≤ 4000 12.0 20.0 ⎯ >1000 and ≤ 1250 3.0 ⎯ >1600 and ≤ 2000 5.0 4.6 8.0 20.0 16.0 25.0 12.5 3.0 16.0 >3200 and ≤ 4000 12.0 ⎯ >1000 and ≤ 1250 6.0 5.0 9.2 8.6 6.0 11.0 ⎯ >2000 and ≤ 2500 7.0 36.0 20. supplementary and reinforced insulation Working voltage (V) P Creepage distance (mm) Pollution degree 1 2 3 Material group Material group I II IIIa/IIIb I II Type of insulation IIIa/IIIb B* ) S* ) R* Verdict ⎯ ⎯ X P ⎯ ⎯ N/A ⎯ N/A >125 and ≤ 250 1.0 12.0 32.0 40.0 >500 and ≤ 800 1.0 6.0 20.0 2.1 10.8 3.0 ⎯ >400 and ≤ 500 2.8 8.6 ⎯ >400 and ≤ 500 1.5 16. basic.5 16.0 100.5 ⎯ >800 and ≤ 1000 4.2 6.3 8.0 >400 and ≤ 500 1.0 12.0 32.3 2.0 >1600 and ≤ 2000 5.0 25.3 7.0 5.0 >2500 and ≤ 3200 10.0 >1250 and ≤ 1600 4.3 ⎯ >250 and ≤ 400 2.0 12.3 >250 and ≤ 400 1.0 22.0 64.5 10.4 10.3 2.0 32.0 18.8 4.0 40.0 25.0 20.0 50.0 50.0 2.0 40.1 8.0 10.0 ⎯ >2500 and ≤ 3200 10.0 80.0 18.0 12.2 12. 0 28.0 72.0 ⎯ >500 and ≤ 800 1.0 10.0 25.0 11.0 25.0 56.0 28.2 4.0 50.0 36.6 5.0 32.0 40.0 32.0 ⎯ >4000 and ≤ 5000 16.0 18.0 11.0 12.0 22.0 12.0 44.6 14.0 12.2 5.0 11.0 36.2 10.0 >250 and ≤ 400 1.0 32.0 32.6 8.0 16.0 2.5 18.0 45.0 64. 0 36.0 ⎯ >4000 and ≤ 5000 32.Page 27 of 35 29.0 >6300 and ≤ 8000 25.0 ⎯ >8000 and ≤ 10000 64.0 72. B = Basic.0 40.0 110.0 112.0 280.0 126.0 40.0 71.0 50.0 50.0 56.0 63.0 64.0 100.2 Report No.: HZ08020150-001 Amendment 1: 2009-03-06 TABLE: Creepage distances.0 180.0 125.0 100.0 220. TTRF_IECEN60335_2_2D2 ) S* ) R* Verdict ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ N/A ⎯ N/A ⎯ N/A ⎯ ⎯ ⎯ N/A ⎯ N/A ⎯ N/A N/A .0 ⎯ >6300 and ≤ 8000 50.0 ⎯ >10000 and ≤ 12500 40.0 160.0 ⎯ >6300 and ≤ 8000 25.0 32.0 45. supplementary and reinforced insulation Working voltage (V) P Creepage distance (mm) Pollution degree 1 2 3 Material group Material group I II IIIa/IIIb I II Type of insulation ) IIIa/IIIb B* >4000 and ≤ 5000 16.0 80.0 56.0 71.0 140.0 125.0 160.0 100.0 80.0 160.0 40.0 32.0 50.0 100.0 45.0 ⎯ ) * .0 80.0 25.0 50.0 80.0 100.0 100.0 200.0 >8000 and ≤ 10000 32.0 80.0 ⎯ >5000 and ≤ 6300 20.0 110.0 112.0 90.0 63.0 126.0 36. basic.0 80.0 71.0 160.0 200.0 250.0 90.0 80.0 ⎯ >8000 and ≤ 10000 32.0 28.0 71.0 126.0 140.0 200.0 20.0 50. S = Supplementary and R = Reinforced TRF No.0 125.0 63.0 90.0 63.0 142.0 80.0 40.0 ⎯ >5000 and ≤ 6300 40.0 >10000 and ≤ 12500 40.0 50.0 ⎯ >10000 and ≤ 12500 80.0 125.0 160.0 25.0 142.0 320.0 100.0 100.0 63.0 250.0 100.0 >5000 and ≤ 6300 20.0 56.0 56. 7 1.0 5.0 36.5 18.0 12.0 25.3 0.0 10.5 2.0 1.0 20.0 63.0 12.2 N/A >125 and ≤ 250 0.0 40.0 18.0 45.3 9.0 5.8 1.0 16.5 6.0 N/A >1250 and ≤ 1600 4.1 10.0 22.0 32.0 80.0 7.0 32.8 3.0 N/A TRF No.0 N/A >3200 and ≤ 4000 12.5 5.8 3.2 6.0 32.0 40.6 1.0 20.3 N/A >500 and ≤ 800 1.0 1.0 N/A >400 and ≤ 500 1.5 N/A >1000 and ≤ 1250 3.0 N/A >2000 and ≤ 2500 7.4 1. TTRF_IECEN60335_2_2D2 .0 2.0 9.0 160.0 100.5 10.0 10.2 4.0 N/A >8000 and ≤ 10000 32.2 3.0 50.0 20.0 28.3 8.4 4.0 22.5 16.0 40.0 80.2 5.0 N/A >2500 and ≤ 3200 10.5 16.0 100.0 71.0 90.8 N/A >50 and ≤ 125 0.5 14.1 1.8 4.0 45.6 2.0 14.0 125.2 Report No.2 0.0 2.6 6.0 11.0 100.0 140.0 2.6 0.0 N/A >4000 and ≤ 5000 16.0 40.0 N/A >800 and ≤ 1000 2.0 2.0 36.0 110.0 N/A >5000 and ≤ 6300 20.0 125.6 8.0 80.0 71. functional insulation Working voltage (V) P Creepage distance (mm) Pollution degree 1 2 3 Material group Material group I II IIIa/IIIb I II IIIa/IIIb Verdict / Remark ≤ 50 0.0 20.0 16.0 56.6 8.0 56.0 50.0 N/A >6300 and ≤ 8000 25.0 63.0 12.0 50.0 5.4 1.0 12.0 11.: HZ08020150-001 Amendment 1: 2009-03-06 TABLE: Creepage distances.0 32.0 25.2 4.2 P >250 and ≤ 400 0.Page 28 of 35 29.4 1.0 28.8 1.0 N/A >1600 and ≤ 2000 5.0 63.8 2.0 N/A >10000 and ≤ 12500 40.0 25.0 4.0 50.4 2.0 25. China Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www. RJD-14-***) Photo 2 Description: Overall view (for RJD-12-***. Xiasha Economic Development District. Hangzhou 310018.Page 29 of 35 Appendix – Photographs Report Ref.. 1 Ave.intertek-etlsemko. RJD-14-***) Intertek Testing Services Hangzhou Ltd.com . No: HZ08020150-001 Amendment 1: 2009-03-06 Photo 1 Description: Top view (for RJD-12-***. 16 No. China Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.com . Xiasha Economic Development District. 1 Ave.. 16 No. No: HZ08020150-001 Amendment 1: 2009-03-06 Photo 3 Description: Overall view (for RJD-12-***. RJD-14-***) Photo 4 Description: Overall view (for RJD-12-***.intertek-etlsemko. Hangzhou 310018.Page 30 of 35 Appendix – Photographs Report Ref. RJD-14-***) Intertek Testing Services Hangzhou Ltd. 1 Ave.com . RJD-14-***) Intertek Testing Services Hangzhou Ltd. 16 No. No: HZ08020150-001 Amendment 1: 2009-03-06 Photo 5 Description: Overall view (for RJD-12-***. Hangzhou 310018.. RJD-14-***) Photo 6 Description: Switch view (for RJD-12-***. Xiasha Economic Development District. China Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.Page 31 of 35 Appendix – Photographs Report Ref.intertek-etlsemko. com . 16 No.. Xiasha Economic Development District.Page 32 of 35 Appendix – Photographs Report Ref. RJD-14-***) Photo 8 Description: Blowing function overall view (for RJD-12-***. RJD-14-***) Intertek Testing Services Hangzhou Ltd.intertek-etlsemko. Hangzhou 310018. No: HZ08020150-001 Amendment 1: 2009-03-06 Photo 7 Description: Spiracle view (for RJD-12-***. 1 Ave. China Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www. No: HZ08020150-001 Amendment 1: 2009-03-06 Photo 9 Description: Spiracle view (for RJD-12-***. RJD-14-***) Photo 10 Description: internal view (for RJD-12-***.Page 33 of 35 Appendix – Photographs Report Ref. 16 No. China Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.. Hangzhou 310018. 1 Ave. Xiasha Economic Development District.intertek-etlsemko.com . RJD-14-***) Intertek Testing Services Hangzhou Ltd. Hangzhou 310018. 1 Ave. China Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www. No: HZ08020150-001 Amendment 1: 2009-03-06 Photo 11 Description: Internal spiracle view (for RJD-12-***. RJD-14-***) Intertek Testing Services Hangzhou Ltd.Page 34 of 35 Appendix – Photographs Report Ref.intertek-etlsemko. Xiasha Economic Development District.com . RJD-14-***) Photo 12 Description: Internal view (for RJD-12-***.. 16 No. 16 No. 1 Ave. Hangzhou 310018. China Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.intertek-etlsemko. No: HZ08020150-001 Amendment 1: 2009-03-06 Photo 13 Description: the water tank (from left to right: 15L. 20L.. Xiasha Economic Development District.Page 35 of 35 Appendix – Photographs Report Ref. 50L. 25L. 30L. 60L) (for RJD-12-***. RJD-14-***) Intertek Testing Services Hangzhou Ltd.com .
Copyright © 2024 DOKUMEN.SITE Inc.