MATERIAL SUBMITTAL NO. DESCRIPTION Fluorescent batten fitting of slim crosssection. Clip-on cover plate and adjustable end cap system. Indoor General Lighting (Air Lock area) E3PP136 ThornUK . Clip-on cover plate and adjustable end cap system with reflector.2 x 36W. Indoor General Lighting CAT. AREA USED Substation. PP236 + PPRE24 MAKE ThornUK 2. Substation. switch start.2 x 36W. T8 .LIST OF MATERIALS Sn 1. switch start. with 3 hours back-up power from self contained battery with charger. Indoor Emergency Lighting E3PP236 + PPRE24 ThornUK 3. Substation.1 x 36W. T8 . with clip-on cover plate and adjustable end cap system with reflector. Fluorescent batten emergency fitting of slim cross-section. T8 . switch start. Fluorescent batten emergency fitting of slim cross-section. with 3 hours back-up power from self contained battery with charger. housing flat glass.2 x 36W. Fluorescent batten fitting of slim crosssection. T8 . HF Electronic controlgear. Enclosed Floodlight with black aluminum body and frame.4 ThornUK .4. switch start. Cast Aluminum bulkhead lamp fitting with moulded glass cover for discharge lamps. Integral controlgear and assymetrical reflector for 100W HPS-T lamp. T8 – 2 x 36W. with clip-on cover plate and adjustable end cap system with reflector. Battery Room P7236/S4 /HF ThornUK 6. IP65 protection. EEX ed. HPS-E 70W High Pressure Sodium Lamp with Integral Gear. Substation External Lighting – Transformer Area (Mounted on exterior walls of Substation) SONPAK 7/15 OT100T. Fire Fighting Gas Cylinder Room PP236 + PPRE24 ThornUK 5. Substation External Lighting (Mounted on exterior walls of Substation) DB70 ThornUK 7. ATEX Cat 2 Gas group IIB & IIC certified. polycarbonate L alloy bodied fluorescent fitting with polycarbonate cover and rapid fix flexible installation channel. 8. Substation Exit Sign on Doors. EFX3-NM ThornUK . Self contained single sided exit sign with 8W fluorescent lamp for non-maintained emergency lighting for 3 hour duration. INDOOR LIGHTING FIXTURES . 500cd/m2 for VDT insert louvres (1000cd/m2 for single Architectural Up/Downlight louvre . (Emergency EN 60598 2. 70W. 60 42 82 Single • 5 year guarantee* on ‘Super Pack’ versions • ‘Super Pack’ versions supplied with HF ballast and Tri-Phosphor lamp for maximum economic operation and minimum maintenance • No conversions . Battens. 36W.Popular Range Battens 18W. • Adjustable twin lampholder provides uniform light in low ceiling installations or downward light in high mounting positions • Tool-less clip-on cover plate for quick installation • Dimmable Digital Controlite versions allow dimming down to 1% lamp power • Single and Twin body in 5 lengths from 600mm to 2400mm (2ft – 8ft) • High frequency electronic or switch start wire wound gear • A range of diffusers and reflectors covering every application requirement • Can be surface or suspension mounted • Twist-lock lampholders for reliable electrical contact • Slim spine with durable. corrosion resistant finish * Conditions apply Twin (lampholder narrow position) Twin (lampholder wide position) 81 64 82 125 Materials/Finish Batten: Rolled steel section in pre-coated high reflectivity white paint.standard range includes maintained emergency versions. Lampholder assembly: Tough white polycarbonate. 58W.22) Standard T8 (3500K) G13 Super Pack 1: 10 T8 835 (3500K) G13 SLL LG3 65°.thornlighting. the original fluorescent batten. 100W EN 60598.2 x 36W is 1500cd/m2) The only one called ‘Pop Pack’. louvre and reflector attachments are suitable for emergency lighting. 90 www.uk .co. co.65 9. No.82 0.73 0.74 0.600mm. E3PP136/E3PP236/E3PPZXL13/ E3PPZXL236 .30 PPZXL170* 3.23 7.5 3. T8 1 x 36W 1223 2.90 PPZXL136* 2.45 4.25 E3 E3 E3 E3 E3 E3 PP136 PP236 PP158 PP258 PP170 PP270 Controlite Digital Dimming Versions (Lamps to be ordered separately).85 4. Specification To specify state: Fluorescent batten fitting of slim cross-section with clip-on cover plate and adjustable end cap system.45 3.53 0.5 3.25 4.89 0.40 5.6 0.10 Axial 2.48 0.7 0.25 3.76 0.uk 91 . Ambient temperature: Switchstart -5°C to 25°C.20 9.60 4.35 PP158CLDLL 3.3 0.0 0. Emergency fixing centres: E3PP158/E3PP170 .2 1.10 PPZXL236* 2.81 0.10 PP136CLDLL 2.86 0.3 0.0 4.5 2.recommended minimum space between luminaires 50mm). High frequency electronic -15°C to 25°C. www.71 0.05 1523 2.40 7.61 0.95 1523 2.2 0.51 0.05 PPZXL158* 3.80 9.84 0.00 Ordering Guide Supplied complete with lamp(s).thornlighting.65 0.500mm. As Thorn Popular Pack Batten.1110mm E3PP258/E3PP270/E3PPZXL15/ E3PPZXL258/E3PPZXL170/E3PPZ XL270 .5 0.0 0.) Bare battens can be mounted end-to-end (except emergency versions .30 7.62 0.85 7.75 0.60 1.46 0.85 0.65 613 613 1223 1223 1523 1523 1787 1787 2398 2398 1.10 9.30 PP236CLDLL 3.600mm. dry.15 2.89 0.86 0. PP258 (Narrow Position) ULOR: 0. unless otherwise stated.05 3.80 2.5mm2 cables.42 2.30 DLOR: 0. Angled terminal block for easy wiring.57 0.95 PP118 PP218 PP136 PP236 PP158 PP258 PP170 PP270 PP1100 PP2100 E3 E3 E3 E3 E3 E3 PZXL136* PZXL236* PZXL158* PZXL258* PZXL170* PZXL270* 3. Emergency version Cat.56 0. 2400mm .69 5.0 trans 2.92 0.76 0.50 10.64 0.25 PPZXL258* 3.40 6.25 3.95 E3PP136CLDLL T8 2 x 36W 1223 2.1200mm (HF electronic versions have no central fixing.69 0.95 3.77 0.85 0. Fixings via three BESA piercings.16 2.81 0. 1200/1500/1800mm . Weight (kg) .0 axial Open area Min illum (lux) 0.6 0.69 0.63 0.6 0. To order a complete luminaire quote required batten and corresponding attachment catalogue number(s). Lamp type & rating Super Pack T8 1 x 36W T8 2 x 36W T8 1 x 58W T8 2 x 58W T8 1 x 70W T8 2 x 70W Switchstart T8 1 x 18W T8 2 x 18W T8 1 x 36W T8 2 x 36W T8 1 x 58W T8 2 x 58W T8 1 x 70W T8 2 x 70W T8 1 x 100W T8 2 x 100W Overall Weight Length (kg) (mm) Cat. indoor atmospheres.5 0.70 2.2 Cat.72 0.80 10.5 Mounting height (m) 2. 120° 180° cd/1000 lm 120° 90° 50 A 60° 100 150 30° 0° 90° T 60° 30° Cat.3 0.45 1787 2.15 E3PP236CLDLL T8 1 x 58W 1523 2.00 7.48 0.70 2.05 3.75 1223 2. high frequency 835).8 0. Normal.80 Axial 8.5 3.94 LMC: A F L U O R E S C E N T B AT T E N S & S Y S T E M S Utilisation factors UF (F) Mounting: Ceiling Reflectances C W F 0.10 Trans 9.73 0.72 0.30 10.50 PPZXL270* 3.0 0.84 0.55 PP258CLDLL 3.67 0.5 0. No.95 3.INDOOR COMMERCIAL Installation/Mounting Four-way terminal block with capacity for 2 x 2.77 0.0 3.1410mm. No.70 6.10 3.80 0.0 3.5 0. one central and two at fixing centres: 600mm . E3PPZXL258 (Narrow Position) 2m Escape route Min illum Mounting (lux) height (m) 1.30 1787 2.55 E3PP258CLDLL Popular Range Batten with Architectural Up/Downlight Attachment * With 835 (3500K) lamp.5 Max spacing (m) centre to end between centres 3. No.0 0.57 Room Index 3.High Frequency Electronic Ballast 1223 1.64 LOR: 0.72 0.12 5.5 Max spacing (m) centre to end between centres Trans 2. (switchstart 3500K standard white.35 E3PP158CLDLL T8 2 x 58W 1523 2.78 0.80 0.0 3. bright Zinc plated Specification To specify state: Open-ended.narrow .narrow . Asymmetrical Metal Reflector • For use where wall washing light is required • Twin batten offers alternative lumen distribution with adjustable lampholder Specification To specify state: Single side angled reflector in white stove enamelled steel.for 1 x 100W Economy reflector .for 1 & 2 x 36W Economy reflector .narrow . As Thorn Popular Range Metal Reflector (PPR). As Thorn Popular Range Angled Metal Reflector (PPA).for 1 & 2 x 100W Rack reflector for 1 & 2 x 58W Rack reflector for 1 & 2 x 70W Asymmetrical reflector for 1 & 2 x 36W Asymmetrical reflector for 1 & 2 x 58W Asymmetrical reflector for 1 & 2 x 70W Optional wire guard for reflector Cat. PP/PT GE 4 PP/PT GE 5 PP/PT GE 6 PP/PT GE 8 PP/PT GE 24 PP/PT GE 25 PP/PT GE 26 PP/PT GE 28 133 110 Asymmetrical metal reflector twin www.Popular Range Reflectors 4:1 0 INDOOR COMMERCIAL Choice of Economy.uk 93 .wide .for 1 & 2 x 36W Economy reflector . No. 92. Rack Lighting Reflector • For use where vertical illumination is required in narrow aisle racking • Continuous end to end mounting possible (except emergency versions) Specification To specify state: Rack lighting reflector in high reflectivity polished aluminium. As Thorn Popular Range Rack Lighting Reflector (PPRL).5 51 92.5 Cat. F L U O R E S C E N T B AT T E N S & S Y S T E M S Narrow economy reflector Wide economy reflector with wire guard Rack lighting reflector Asymmetrical metal reflector Economy Reflectors • For cost conscious schemes • Narrow reflector for lowest cost • Wide reflector for highest light output • Wire guard available • Continuous end to end mounting possible (except emergency versions and wire guard) 50mm spacing minimum recommended Materials/Finish Reflectors: Steel with precoat high reflectivity white finish Wire guards: Steel.thornlighting. trough reflector in white stove enamelled steel with optional wire guard (PP/PT GE).for 1 & 2 x 70W Economy reflector .wide .narrow .wide . No.for 1 & 2 x 58W Economy reflector .wide .5 199 133 287 121 167.for 1 & 2 x 58W Economy reflector . PPRE 4 PPRE 5 PPRE 6 PPRE 8 PPRE 24 PPRE 25 PPRE 26 PPRE 28 PPRL 5 PPRL 6 PPA 4 PPA 5 PPA 6 121 Narrow reflector Economy reflector .co. Asymmetric and Rack reflectors for use with Popular Battens.5 79 Narrow reflector (lampholder narrow position) Wide reflector (lampholder narrow position) Rack lighting Asymmetrical metal reflector single Ordering Guide Description 92.for 1 & 2 x 70W Economy reflector . EXPLOSION PROOF LIGHTING FIXTURES . co. 36W. P 718/SC P 736/SC P 758/SC P 770/SC P 718/WG P 736/WG P 758/WG P 770/WG P 7/PC40 P 7/PM Weight (kg) 5.5 10.vertical and horizontal at each end.T6 (see certification detail) 220/240V.5 9. Cable entries: 2 x 20mm each end . each end A M8 each end 158 Emergency version B 140 Standards Zone: ATEX Cat 2 (can also be used in Cat 3) Zone 1 (can also be used in Zone 2) Gas Groups: 11C 18W T8.T6 EN50014 and 50018 SIRA 01 ATEX 1033 18W 36W T8 58W 70W 36W TC-L 55W TC-L T6 @ Ta = 40°C 11C T6 @ Ta = 40°C 11C T6 @ Ta = 40°C 11C T5 @ Ta = 40°C 11C T6 @ Ta = 40°C 11C T6 @ Ta = 40°C 11C 18W 36W 58W 70W T8/36W + 55W TC-L T8 T8 T8 Dim A fixing centres 632 1242 1542 1806 Dim B o/a length Standard 752 1362 1662 1926 Dim B o/a length Emergency 752 1490 1790 - Ordering Guide Lamps to be ordered separately. 70W T8 1: 1 INDUSTRIAL bi pin 36W. No.5 10.0 9.5 6. 2 x M20 or equiv.0 Emergency Cat.0 - P 7236/S4/HF/EM P 7258/S5/HF/EM P 7236/S2/HF/EM - Installation/Mounting 2 x M8 tapped holes . www. IP66. PROOF | HAZARDOUS AREA LUMINAIRES • Ideal for general indoor and outdoor lighting • Please ask for advice regarding use in atmospheres with organic contaminants • Lamp/gear access from either end of luminaire • Lightweight for ease of installation • New high output compact fluorescent lamp versions • Integral high frequency electronic ballast • Emergency (3hr duration) versions available as standard Materials/Finish Body: Aluminium alloy finished Petrelux green.0 5.0 9. Lamp type & rating T8 600mm 1 x 18W T8 1200mm 1 x 36W T8 1500mm 1 x 58W T8 1800mm 1 x 70W T8 600mm 2 x 18W T8 1200mm 2 x 36W T8 1500mm 2 x 58W T8 1800mm 2 x 70W TC-L 2 x 36W TC-L 2 x 55W Accessories Description Overhead canopy for 18W T8/36W x 55WTC-L luminaires Overhead canopy for 36W T8 luminaires Overhead canopy for 58W T8 luminaires Overhead canopy for 70W T8 luminaires Wire guard for 18W T8/36W x 55WTC-L luminaires Wire guard for 36W T8 luminaires Wire guard for 58W T8 luminaires Wire guard for 70W T8 luminaires Pole clamp mounting kit for 40mm Ø pole Pendant mounting kit Cat. 36W TC-L and 55W TC-L 11B 36W T8. Specification To specify state: EEx d Flameproof/Emergency fluorescent luminaire in aluminium alloy and polycarbonate overtube.0 12.5 12.3 entries fitted with plugs. P 7136/S4/HF/EM P 7158/S5/HF/EM 12.ISO thread .0 5.thornlighting.uk 301 .T5 .5 9. No. Terminals: 3 wire plus earth max conductor 4mm2 and suitable for looping.5 Cat. No. P 7118/S2/HF P 7136/S4/HF P 7158/S5/HF P 7170/S6/HF P 7218/S2/HF P 7236/S4/HF P 7258/S5/HF P 7270/S6/HF P7236/S2/HF P7255/S2/HF Weight (kg) 11. 58W T8 and 70W T8 T Rating: Voltage: IP Rating: Certification Code: Certification Standard: Approval Authority: Certificate Number: Certification Detail: T4 . 50/60Hz IP66 to IEC 529 EEx d 11B and 11C T5 . 2 pack epoxy with pre-treated and primed surface.Petrelux 7 18W. 58W. As Thorn Petrelux 7/Petrelux 7 Emergency.5 5. Overtube: Polycarbonate. 55W TC-L 2G11 For Standards see below A Zone 1 (ATEX Catagory 2) Flameproof EEx d linear fluorescent luminaire for surface or suspended mounting. OUTDOOR LIGHTING FIXTURES . 53 0.6 0.DB Bulkhead 70W HPS-E E27 150W. IP65 protection.78 0.69 LOR: 0. No.48 5.0 0.72 0.75 0.60 1. Bowl: Moulded borosilicate prismatic glass in hinged aluminium frame retained by four stainless steel Allen screws.53 0.40 0.68 0.66 0.6 0.8 0.67 0. No.10 DLOR: 0.3 0.79 SHR max: 1. 50Hz IP65 EN 60598 A tough bulkhead for discharge or tungsten lamps for use in non-hazardous areas.thornlighting.63 0. Lamp type & rating HPS-E 70W GLS 150/200W Description Integral gear ES lamp not supplied Weight (kg) 6.60 0.59 0.57 0.44 0.68 0.43 0.6 0.92 LMC: E Utilisation factors UF (F) Reflectances C W F 0.0 0. DB70 Lamp: 70W HPS-E ULOR: 0.75 0.65 0.5 0.67 0. one with removable plug for through wiring.5 0.37 0.75 0.70 0. No.63 0.0 0. GLS less lamp.0 4. Ordering Guide HPS-E versions supplied complete with lamp.7 0. DB70 DB200 90° cd/1000 lm 90° 50 60° A 100 150 30° 0° 30° T 60° Spares and Attachments Description Glass bowl Wire guard Cat.3 Cat.2 0.3 0. DBG DBW Cat. 200W 1: 1 GLS E27 220/240V.69 0.64 0.62 0.3 0.61 0.72 0.co.69 0.47 0.5 0.0 0. Reflector/gear tray: White painted steel.71 0.58 0. • Ideal for localised lighting • Robust cast aluminium body and glass bowl resist impact and corrosion • Wire guard option for added protection Materials/Finish Body: Pressure die cast LM6 aluminium finished hammer grey.60 0.51 0.65 0.36 0. 192 296 fxg crs 170 105 fxg crs 314 Installation/Mounting Direct ceiling or wall mounting.5 0.72 0.44 0. Specification To specify state: Cast aluminium bulkhead with moulded glass cover for discharge/tungsten lamps.uk .34 2.56 0.0 4.2 300 www.49 0.2 Room Index 3. Suitable for 40°C maximum ambient depending on orientation. As Thorn DB Bulkhead. M20 cable entry at each end.68 0.64 0. Sonpak 7/15 70W IP65 EN 60598 HPS-T E27 (external ignitor) 5 joules 960˚ Hotwire 1: 1 OUTDOOR 100W. RAL 9005. Sealed to IP65. polyester painted black.105 0.4 OT100T. No. See page 372 for attachments.0 9.4 Lamp: 150W HPS-T 30° 60° 90° horizontal vertical www. 900 750 600 450 300 250 cd/1000 lm Note that brackets above are suitable for use with QC-TC and QCZR (76mm Ø shaft) columns. refer to page 553 for details. Ordering Guide Supplied complete with lamp. Aiming angle of floodlight aided by goniometer. Stirrup fixed by single bolt through 21mm Ø hole. OTWGB OTLB OTSSB OHA4613 QCB F1 QCB F2 QCB F3 DELTA QCB F4 CROSS Specification To specify state: Enclosed floodlight with black aluminium body and frame.105 Weight (kg) 9. Installation/Mounting One glanded cable entry for 9-13mm o/d cable with 3 pole terminal block for up to 10mm2 cables. OT70T. with a further two 13mm Ø fixing holes at 250mm centres. Lamp type & rating HPS-T (external ignitor) HPS-T HPS-T HIT-DE Windage (m2) 0. Two additional 11mm Ø fixing holes at 102mm centres.4 OT150T. housing flat glass. No.105 0. Integral control gear and asymmetrical reflector for 70W/100W/150W HPS-T or 150W HIT-DE lamp. one on the other.co.4 OTMH150D. Stirrup: 3mm mild steel.4 70W 100W 150W 150W Export voltages available. Lens: Tempered 4mm flat glass with stainless steel bolts and silicone rubber gasket. These attachments cannot be mounted together. Reflector: Dimpled anodised aluminium.0 9. As Thorn Sonpak 7/15. 150W Ta Max: +25˚C HPS-T E40 150W HIT-DE Rx7s Discharge floodlight for general area lighting.0 9. 21mm Ø knockout at rear for through wiring. RAL 9005. *Supplied with 4 screws and washers. OT150T. painted black. No.thornlighting. Attachments Description Wire guard Louvre* Spill shield for environmentally sensitive areas* Pole clamp for use with 48-89mm Ø poles Sonpak single mounting bracket (76mm Ø shaft) Sonpak twin stirrup version mounting bracket (76mm Ø shaft) Sonpak triple stirrup version mounting bracket (76mm Ø shaft) Sonpak 4-way stirrup version mounting bracket (76mm Ø shaft) Cat. AREA FLOODLIGHTING • Choice of high pressure sodium or double-ended metal halide lamps in a variety of wattages • Robust die-cast aluminium body and front frame • Asymmetrical reflector • Toughened glass front • Integral control gear • Spill shield available for reduced glare (see page 372) • Easy installation with drop down front glass and cable entry • Adjustable streamlined stirrup for flexibility in mounting • Sealed to IP65 115 127 335 400 365 256 192 Materials/Finish Body and front frame: Die-cast aluminium. 0 -90° -60° -30° 0° Cat.0 Cat.105 0.uk 373 . EMERGENCY LIGHTING FIXTURES . EFXF EFXE 1 EFXE 2 EFXE 3 EFXE 4 Pictograms Cat. T5.8 EFX3 EFX3/BR White Brass 3 3 2. Ordering Guide Supplied complete with lamp. 20mm BESA provision in back plate or 20mm Ø conduit knockout on either end. white fluorescent. No. Ceiling or wall mounting options Choice of white or brass finish Strong. Steel construction. Key Features G Installation/Mounting Ceiling or wall mounting.8 2.5mm2 capacity. Legends to be ordered separately.8 2. Standards Designed and manufactured to comply with EN 60598 2. Screw fixings in back face. As Thorn EFX3.COMMERCIAL LIGHTING Voyager 8W Single Sided Exit 1: 1 EMERGENCY LIGHTING 515mm 320mm fixing centres 60mm 191mm 150mm fixing centres A simple ceiling or wall mounted emergency exit sign luminaire for general interior use. Attachments Euro Legends Cat. maintained and sustained options to match application needs Extensive choice of legend panels to match scheme style G G G G Lamp Type 8W.8 EFXS3 EFXS3/BR White Brass 3 3 2. 2 x 2. Lamp type & rating Non-Maintained T5 8W T5 8W Maintained T5 8W T5 8W Sustained T5 8W T5 8W White Brass 3 3 2.8 EFX3 NM EFX3 NM/BR Description Duration (hrs) Weight (kg) Cat. No. cap: G5 Materials/Finish Body: Folded steel construction with white stove enamelled or brass finish Electrical Characteristics Supply voltage: 220/240V Input current: 50mA Frequency: 50Hz Specification To specify state: Self contained single sided exit sign with 8W fluorescent lamp for maintained/non-maintained/sustained emergency lighting for 3 hour duration.8 2. 4 way terminal block. EFXF 7 EFXF 8 EFXF 9 EFXF 10 EFXF 11 103 . durable construction Non-maintained. No.22 Ta: -5°C to +25°C Photometric Data For signage only.