Stm 1 Configuration



Comments



Description

ENGINEERING INSTRUCTIONSTRANSMISSION CPE STM1 EI NO. INSTALATION AND TESTING PROCEDURE OF CUSTOMER PREMISES EQUIPMENT STM1 ITI Make (TEJAS) 1.0 SCOPE: This Engineering Instruction provides Installation information and describes various tests to be conducted on CPE (Customer Premises Equipment) STM1 during commissioning. The system is manufactured by M/s TEJAS Networks, Inc. USA and supplied by ITI. 2.0 GENERAL: The equipment establishes a 622/155 Mb/s trans system whose high flexibility allows to set up various configurations mainly line terminal or insert/ drop multiplexer with protection option. The equipment can be plesiosync or synchronous i.e. 2/34/140 PDH tributaries or 155.520/622 Mb/s synchronous tributaries. The equipment can be configured independently in Mesh, Ring, linear and Bus architectures and also a mix of the above. Also it can be flexibly configured with equipment redundancy for all or for a selected few among the modules. The main features of the system is 1) Easy network manageability 2) Flexible configuration 3) Lower cost per line 4) Easy upgradeability 5) Support for both data and voice over SDH 6) Higher reliability 3.0 INSTALLATION: 3.1 Unpacking: First check the shipment container for any kind of damage and then unpack the equipment pack with upright mark always at the top, remove all shock proof materials, polyethylene packing and ascertain and confirm that no physical damage taken place and items available as per packing list. 3.2 Installation of the Rack: Installation requires fixing of Rack and mounting sub-rack structure in the rack. Drill hole on the floor to fix the rack. (Holes are provided in the base plate of the rack). Fixing of the rack is done by anchor bolt jammed by the help of plugging compound and ensures the verticality of rack. 3.3 E3 (34Mb/s) connection: The E3 (34Mb/s) traffic is received and transmitted through an interface (TE31) card. The connectivity is made through two BNC connectors (Tx & Rx). 3.4 Ethernet connection: The Ethernet traffic is received and transmitted through an Ethernet interface (TP01) card. The connectivity is made through an RJ45 connector. Connect the cable to RJ45 connector to the marked position and ensure that retention slide operates to hold the connector in place. 3.5 STM1 connection: (Optical) The STM1 optical traffic is received and transmitted through STM1 interface on the base card. The connectivity is made through an SC connectors (Tx & Rx). BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 1 of 11 Issue 1 Date 254) Click on Provisioning ----> STM Ports ----> STM1-3-1----> *) Admin Status: Admin Up *) ECC byte selection: DCC_M *) TIM Action: Tim ignore Submit changes and accept the Modifications. ( As you wish) 2) Router ID: Give the Address ( Ex: 192. type the line below in the address space: http://192.168.1. 3. Please use a PC/Laptop and Configure the PC/laptop IP Address to: 192.255.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO.254) 4) Contact: Give the contact details (As you Like) 5) Location: Give the location name. (Please use straight cable. which is present on the Sticker on the Node.0 & Default Gateway to: 192.1) 3) Ethernet IP: Give the Address ( Ex: 192. BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 2 of 11 Issue 1 Date .1.168.168. if both the Tejas Node & PC/Laptop are connected through Hub/Switch) Open the Internet Explorer in the Windows PC.1.1. The connectivity is made through two BNC connectors (Tx & Rx). 3. The Factory default IP address for Tejas Multiplexer is: 192.1 or the Node IP Address. you can login to the system) If you are connecting other Tejas Node to this Local Node.168.6 STM1 connection: (Electrical) The STM1 electrical traffic is received and transmitted through STM1 interface on the base card. Connect the cable to RJ45 connector and ensure that retention slide operates to hold the connector in place. ( As you like) Submit changes and accept the Modifications. Click on Provisioning ----> STM Ports ----> STM1-3-2----> *) Admin Status: Admin Up *) ECC byte selection: DCC_M *) TIM Action: tim_ignore Submit changes and accept the Modifications.7 Diagnosis connection: The system allows diagnosis through an RJ45 connector available on base card. to completely come-up [before trying to ping or access the node (through Internet Explorer)].254.168. *) Click on Provisioning ----> STM Ports ----> AU4-3-1-1-1----> *) Signal Label: tug structure *) TIM Action: Ignore TIM Submit changes and accept the Modifications. (System will go to the warm-reboot state and after 3 minutes.254 or the One. 4.254.1.168.2.0 PROCEDURE FOR ACCESS & CONFIGURE THE EQUIPMENT: Switch ON the Node and wait for at least 7 minutes for the node.200 Subnet Mask to: 255. Connect a cross cable to the PC/Laptop Ethernet port to the NMS port on Tejas MC-1/4/LT/CP.254:20080 Give the User Name: tejas and Password: j72e#05t Configuration:(One Time Configuration) 1) Name: Give the Name of the Site/Location.168.255.168. then set the Remote node with the Router ID & Ethernet IP as follows: Router ID: Give the Address ( Ex: 192.2) Ethernet IP: Give the Address ( Ex: 192. *) Click on Provision (main menu) -----> Click on VCG Group ---> VCG-4-x Admin Status: adminUp Sequencing Mode: Automatic Sequencing *) Click on Provision (main menu) -----> Click on VCG Group -> VCG-4-101 --> Add new VC Port: STM1-3-1 STM No: 1 K. Submit the changes and keep on adding the required VC-12's. *) Click on Provision (main menu) -----> Click on E1 ports Admin Status = adminUp Submit the changes and make all E1(required) ports admin status to AdminUp.L. *) Click on Timing Manager (main menu) ---> Nominate Clock ----> *) Clock Reference: Port *) Clock Reference Port: STM1-3-1 *) Priority: 1 Submit the changes and do the same steps.M = Select the Assigned TUG structure and Assign Sequence Number. ( System will go to the warm-reboot state and after 3 minutes. Submit the changes and accept the modifications. Repeat the above same steps for other E1/E3.M ) = select from the menu (TUG Structure) destination port = E1-4-1 Destination time slot = --Enable Source protection and select the TUG Structure. *) Click on Fault Management (Main Menu) ----> Alarms -----> See the current Alarms *) Click on Fault Management (Main Menu) ----> Events -----> See the History of Alarms *) Click on Fault Management (Main Menu) ----> Events -----> Show All Alarms -----> See the History of All Alarms BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 3 of 11 Issue 1 Date . *) Click on Provisioning (main menu) -----> Click on Ethernet ports Admin Status = adminUp Submit the changes and make required ports admin status to AdminUp. *) Click on Provisioning (main menu) -----> Click on OSPF Parameters *) OSPF Globle: Enable *) OSPF Ethernet: Enable Submit changes and Accept the Modifications. TRANSMISSION CPE STM1 EI NO.L. If you want to nominate more than one Clock source. you can login to the system) *) Click on Provision (main menu) -----> Click on Cross connect --->Click on Add Cross connect-> Cross connect capacity = VC12 Source port = STM1-3-1 source time slot (K.ENGINEERING INSTRUCTIONS Click on Provisioning ----> STM Ports ----> AU4-3-1-1-1----> *) Signal Label: tug_structure *) TIM Action: Ignore TIM Submit changes and Accept the Modifications. 0 TESTS AND TEST PROCEDURE: 6. proper DC wiring to the equipment is done. For continuous trans power.1 Preliminary checks: Before commencing the testing.1 Check of power supply: Measure Dc Voltage drop from float-cum battery charger to the input of equipment and record. Receiver sensitivity Limit: For S1. Fuses of proper rating are provided and grounding of the equipment is properly done.1 -34 dbm For L1. Click on Provisioning--> STM Ports ----> STM1-3-1----> *) Admin Status: Admin Up *) ALS Mode: disable Click on Provisioning--> STM Ports ----> STM1-3-2----> *) Admin Status: Admin Up *) ALS Mode: disable Limit: For S1. It should be less than 1. check of BER on local loop and AIS Frequency measure etc.2. Receiver sensitivity and check of alarms.2 0 to –5 dbm 6.2 6.2 (b) Measure Optical Trans power = ------In dbm. Tests are normally divided into two categories namely Local Tests and Through Tests.080 Mb/s 6. Laser output.0 volt. 6. 6.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO.1 -8 to –15 dbm For L1.2 (a) Measure Optical bit rate = ------------155.520/622. Test on optical interface: 6.2 -34 dbm BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 4 of 11 Issue 1 Date .2.2 (c) Check of Receiver sensitivity/ Dynamic range: Connect the optical variable attenuator in between optical trans and receive port and Laser in forced on condition feed and receive 2 Mb/s between TX and RX with the help of PDH/ SDH analyser. where the BER with no error. certain checks are carried out to see that the equipment is installed as per the layout.2. Reducing the power by varying optical attenuator.2 LOCAL TEST: These tests include power supply to the rack. measure the lower threshold point through optical power meter at the output of attenuator.2.2.1 0 to –5 dbm For L1. 6.1 -28 dbm For L1. clock offset of 0ppm.15 ppm 155.264Mb/s-.75 UI PP Hp2Lp: -----------------------</=0.3.20 ppm 6. +15ppm and -15ppm For 155.368 Mb/s-. For 34.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO.20 ppm 139.2 -10 dbm 6.3.2(d) Check of Optical over load: To measure the optical overload point test set up is same and increase the receive power by varying optical attenuator.3. measure the overload point through optical power meter at the output of attenuator.520 Mb/s----------+/.4 Output Jitter measurement: Measure the Output Jitter tolerance with the help of PDH/ SDH Analyzer.048 Mb/s-------------+/.50 ppm 34.264 Mb/s----------+/.0 Test on Electrical interface: 6. For 2. 6. i) ALS Disable In the ALS disable mode the laser source available continuously (forced on condition) ii) ALS Automatic--Laser on only when receive power available.520 Mb/s Limit Hp1Lp: -----------------------</= 0.368 Mb/s-----------+/.1 Bit rate----------------------Limits: 2. where the BER with no error.3.3 Check of AIS clock: Measure the AIS clock with the help of PDH/SDH analyzer or Frequency counter at the RX electrical port of each tributaries with data input fail and optical input fail Limits: 2.075UI PP Filter For 155.75 UI PP BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 5 of 11 Issue 1 Date . Receiver over load Limit: For S1.2 BER Check: With the help of PDH/ SDH analyser measure the BER in each tributary for a period of 15 minutes by local loop at optical aggregate The result should be no error.1 -10 dbm For L1.048 Mb/s Limit Hp1Lp: -----------------------</= 0.20 ppm 139.264 Mb/s Limit Hp1Lp: -----------------------</= 0.048 Mb/s-.3.2 (e) Laser safety power in case of fiber break: Three modes are available.15 ppm 155.1 -8 dbm For L1.75 UI PP Hp2Lp: -----------------------</= 0. +20ppm and -20ppm 6.clock offset of 0ppm.264 Mb/s----------+/.75 UI PP Hp2Lp: -----------------------</= 0.50 ppm 34.368 Mb/s Limit Hp1Lp: -----------------------</= 0. +50ppm and -50ppm.2.15 UI PP Filter For 139.20 UI PP Filter For 34.048 Mb/s-------------+/.368 Mb/s-----------+/.520Mb/s-.2. +20ppm and -20ppm For 139. iii) ALS Manual--Laser on by manual operation through PC/ Laptop. 6.clock offset of 0ppm.clock offset of 0ppm.20 ppm 6.520 Mb/s----------+/. Filter For 2. 520Mb/s: f1 500 Hz ------------f2 6. Frequency Measured value Limit For 2.2 UI PP >/= 1.2 UI PP >/= 0.tributaries electrical RX of CPE SDH equipment.368Mb/s: f1 100 Hz ------------f2 1.5 UI PP >/= 0.2 UI PP >/= 0.5 UI PP >/= 0.0 Khz ------------f3 10 Khz ------------f4 800 Khz ------------For 139.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO. Measure the BER for 5min.0 >/= 1.2 UI PP >/= 1. 7.and the result better than 1x10-10. Hp2Lp: -----------------------</= 0.15 UI P 6.1 Mapping: The CPE SDH system Trans optical port is connected to the Receive STM1 optical input of the SDH analyser and the PDH 2/34/140/155Mb/s Trans electrical output of the Analyser is connected to the PDH 2/34/140/155Mb/s.264Mb/s: f1 200 Hz ------------f2 500 Hz ------------f3 10 Khz ------------f4 800 Khz ------------For 155. tributaries electrical TX of CPE SDH equipment is connected to the 2/34/140/155Mb/s receive electrical input of the Analyser.5 UI PP >/= 1.2 UI PP >/= 0.2 UI PP SDH test: Mapping/ De-mapping Test: 7.2 UI PP >/= 0.5 UI PP >/= 0.and the result better than 1x10-10.5 Input Jitter measurement: Measure the Input Jitter tolerance with the help of PDH/ SDH Analyser.5 UI PP >/= 1.5 Khz ------------f3 65 Khz ------------f4 1300 Khz ------------7.3. Measure the BER for 5min.048Mb/s: f1 20 Hz ------------f2 93 Hz ------------f3 3700 Hz ------------f4 100 Khz ------------For 34.2 De-mapping: The Optical STM1 Trans output of the SDH analyzer is connected to the receive optical port of the CPE SDH system and the PDH 2/34/140/155Mb/s.5 UI PP >/= 1.5 UI PP >/= 1.5 UI PP >/= 0.2 UI PP >/= 1. BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 6 of 11 Issue 1 Date . ) Monitor the current alarm through PC/ Laptop by local access and select Fault management Alarms The Trans set up of the SDH analyser as TX STM1 Optical / Electrical AU4 VC12 2Mb/s PRBS 15-1 Ch 1/1/1 RX STM1 Optical / Electrical AU4 VC12 2Mb/s PRBS 15-1 Ch 1/1/1 Alarm Simulated LOS LOF MS-AIS MS-RDI AU LOP AU AIS HP UNEQ HP PLM HP RDI TU LOM TU AIS LP UNEQ LP RDI Alarm Information Loss of signal Loss of frame Alarm Indication signal (Line) Remote defect indication (Line) Loss of pointer Alarm indication signal Signal label unequipped Payload mismatch Remote defect indication Loss of Multi-frame Alarm Indication signal (Term) Signal label unequipped Remote defect indication (Term) Severity Critical Critical Critical Critical Major Major Major Major Major Major Major Major Major Object STM1-3-1/2 STM1-3-1/2 STM1-3-1/2 STM1-3-1/2 AU4 1-3-111 AU4 1-3-111 AU4 1-3-111 AU4 1-3-111 AU4 1-3-111 TU12 1311111 TU12 1311111 TU12 1311111 TU12 1311111 Acknowledgement status Unacknowledged. 8. After the receive power measurement. (Note: For the electrical 155Mb/s the above set up is same but instead of optical port.1. Check of Optical receive power: For continuous power. set both the optical Trans ports *) ALS mode: Automatic With the help of optical Time Domain Reflecto meter measure the route length and calculate the expected receive power and compare the result.0 Alarms: Connect the Optical STM1 trans output of the SDH Analyser to the receive optical port of CPE SDH system and vice versa. inject alarm with Anomaly/ Defect analyser and record the alarms. BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 7 of 11 Issue 1 Date . Unacknowledged Unacknowledged Unacknowledged Unacknowledged Unacknowledged Unacknowledged Unacknowledged Unacknowledged Unacknowledged Unacknowledged Unacknowledged Unacknowledged THROUGH TEST: 8. electrical port to be connected both in Analyser and CPE SDH system. Measure the receive power before connector and introduce suitable optical pad for normal working condition. Measure the receiver in power after pad and record the value.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO. Click on Provisioning--> STM Ports ----> STM1-3-1----> *) Admin Status: Admin Up *) ALS Mode: disable Click on Provisioning--> STM Ports ----> STM1-3-2----> *) Admin Status: Admin Up *) ALS Mode: disable disconnect the fiber line receive and connect it to the optical power meter. No error should be observed. 8.2 UI PP >/= 0. 2 BER Check: With the distant end loop at 2. 140.368 Mb/s Limit Hp1Lp: -----------------------</= 0.520 Mb/s----------+/.2 UI PP For 34.0 Khz ------------f3 10 Khz ------------f4 800 Khz ------------For 139.20 ppm 139.2 UI PP f4 100 Khz ------------. 155 measure the Input Jitter tolerance with the help of PDH/ SDH Analyser. Limits: 2. 140.5 UI PP >/= 1.075UI PP Filter For 155.048Mb/s: f1 20 Hz ------------.>/= 1.15 ppm 155.50 ppm 34.264 Mb/s Limit Hp1Lp: -----------------------</= 0.75 UI PP Hp2Lp: -----------------------</= 0. 34.2 UI PP BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 8 of 11 Issue 1 Date .>/= 0.2 UI PP >/= 0.15 UI PP 8.the prescribed offset value and record.5 UI PP f3 3700 Hz ------------.520 Mb/s Limit Hp1Lp: -----------------------</= 0.15 UI PP Filter For 139. 8.75 UI PP Hp2Lp: -----------------------</= 0.368 Mb/s-----------+/.3 Check of AIS clock: Measure the AIS clock with the help of PDH/SDH analyzer or Frequency counter at the RX electrical port of each tributaries with data input fail at distant end. Filter For 2.2 UI PP >/= 1.5.20 ppm 8.264Mb/s: f1 200 Hz ------------f2 500 Hz ------------f3 10 Khz ------------f4 800 Khz ------------- >/= 1. Output Jitter Measurement: With the distant end loop at 2.264 Mb/s----------+/. Frequency Measured value Limit For 2.20 UI PP Filter For 34. 34.>/= 1.5 UI PP >/= 0.75 UI PP Hp2Lp: -----------------------</=0.75 UI PP Hp2Lp: -----------------------</= 0.048 Mb/s-------------+/. 155 measure the Output Jitter tolerance with the help of PDH/ SDH Analyser.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO. 155 measure the Bit error ratio for at least 5 minutes each at normal clock & +/.048 Mb/s Limit Hp1Lp: -----------------------</= 0. 140.5 UI PP >/= 0.5 UI PP f2 93 Hz ------------. 34.5 UI PP >/= 1.>/= 0.368Mb/s: f1 100 Hz ------------f2 1.4. Input jitter measurement: With the distant end loop at 2. Subnet Mask & Default Gateway of your laptop/PC at Local Node A(192. after giving the User name & Password. then connect the Laptop/ PC to Node-D NMS Port and then: *) You have to configure IP Address.: 192.5 UI PP >/= 1.1.254) as follows: IP Address…………… : SubnetMask………….0 192.255.254 (and then press enter key).255.168.1.255. 192.6.4.5 UI PP >/= 0.255.254 *) User Name: tejas and Password: j72e#05t In the command prompt of Windows PC. *) Using Router ID address.520Mb/s: f1 500 Hz ------------f2 6.200 SubnetMask………….255.168.0 192.: 255. give the following command: route add 192. you will be able to see the Remote node UI page.0 Default Gateway……..168.168.. then by giving the http://RouterID:20080 in the Internet explorer.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO.168. give the following command: route add 192.1. Open Internet Explorer and log-in Remote Tejas TJ100MC-1/4/LT.254) as follows: IP Address…………… : 192.255. If you are able to ping. you will be able to Log-in any Node through it’s Router-ID. When you take the Windows Laptop/ PC to remote Node say Node-D.5 Khz ------------f3 65 Khz ------------f4 1300 Khz ------------- >/= 1.255.254 BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 9 of 11 Issue 1 Date .200 255.0 192.168.168. Subnet Mask & Default Gateway of your laptop/PC at Local Node D(192.168.2 UI PP 8. For 155.254 In the command prompt of Windows PC. Now you will be able to ping the remote node with it’s Router ID.4.4.1.254. With this command.1.168.255.1.168.168.168.254) and would like to login Node B (192.2:20080) For Example: You are at Node A (192.168. (http://192.168.: Default Gateway…….254.0 mask 255.254.2) *) You have to configure IP Address. Check the remote supervisory by remote login facility: Remote Access of Tejas MC-1/4/LT/CP (with the help of Router ID): *) Configure your laptop/PC Default Gateway as your local MC-1/4/LT IP address.2 UI PP >/= 0.254 (and then press enter key).0 mask 255. : 192.254.4. #12251) Check for synchronization: *) Click on Timing Manager (main menu) . Segment No: Carrier Byte: Port1 Select the STM Optical Aggr.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO. Now Set the Order Wire No. please follow the below procedure (Not applicable for TJ100CP). 8. as follows: Provisioning Order wire Order Wire No: Ring Timeout: Matching Impedance: and press Submit. Note: The Segment No. (ex. #12123) ( ex.7 Check the loop back facility in SDH/ PDH level: Maintenance operation STM1/PDH Loop back Normal for normal working condition. Order wire no.) For Selective Calling: For Omni-Bus Calling: # Segment No. For Setting the Order Wire. 123) 60 sec 600 Ohms 2. two digit no. for all the Nodes connected through the Optical Fibers should be same (i.16 u F Pl.12) View Order wire Segment(s) Create order wire segment Give any two Normal/ facility loop back/ terminal loop back. # Segment No. 251. Terminal loop back for PDH local loop back. 8. BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 10 of 11 Issue 1 Date . If you want to nominate more than one Clock source.e. Provisioning Order wire digit Segment no.8 Check of Order wire: Check the working of order wire by selective calling each station for ring and speech and repeat the same for group calling.Nominate Clock -*) Clock Reference: Port *) Clock Reference Port: STM1-3-1 *) Priority: 1 Submit the changes and do the same steps. EOW admin status for port1: Port2 Select the STM Optical Aggr. (ex. ( ex. EOW admin status for port2: and then Press Submit. 12 E1 Port 1 Enable Port 2 Enable Any Three Digit no. Facility Loop back for STM port local loop back. LIMIT: % ES % DM % SES 0. BHARAT SANCHAR NIGAM LIMITED A Govt of India Enterprises Restricted to Telecom Staff Page 11 of 11 Issue 1 Date . 34. TJ100MC-1. In revertive mode of selection the stream will restore to its normal working path from protection mode.ENGINEERING INSTRUCTIONS TRANSMISSION CPE STM1 EI NO.0 STABILITY TEST: Connect the system for long-term stability test for 48 hours at the lowest bit rate 2Mb/s. Installation Procedures. and record the error performance. Error occurs in PDH DTA/ SDH Analyzer indicates the traffic change over. when the receive optical path becomes normal.revertive mode.018 0. 140. Hardware description manual. the traffic will switchover to the spare aggregate in protection mode. 155 measure the Bit error ratio and remove any one of the optical receive aggregate. But in non. 8. system will sustain in the last working route.0023 Limit for ES is to be normalized at 64 Kb/s. With the distant end loop at 2. 9.9 Check of Protection switching: APS Automatic protection switching. ABBREVIATION: AIS – Alarm Indication Signal ALS – Auto Laser Shutoff BER – Bit Error Rate CPE – Customer premises Equipment EOW – Engineering Order Wire IP – Internet Protocol NMS – Network Management System PDH – Plesiochronous Digital Hierarchy RX – Receive SDH – Synchronous Digital Hierarchy TX – Trans BIBLIOGRAPHY: TJ100CP. 10.023 0.
Copyright © 2024 DOKUMEN.SITE Inc.