Standard Size of Rooms in Residential Building and Their Locations

April 3, 2018 | Author: drajkumarce | Category: Pantry, Bedroom, Kitchen, Bathroom, Architectural Design


Comments



Description

Standard Size of Rooms in Residential Building and their Locations https://theconstructor.org/building/size-room-location-building/13269/  About Us (https://theconstructor.org/about/) |  Contact Us (https://theconstructor.org/contact-us/) |  Privacy Policy (https://theconstructor.org/privacy-policy/)  (https://twitter.com/theconstructor2)  (https://www.facebook.com/TheConstructor)  (https://plus.google.com/+TheconstructorOrg) Standard Size  Search here ... (https://theconstructor.org/) of Rooms in Residential Building and their Locations Home (https://theconstructor.org) / Building Technology and Construction Guide (https://theconstructor.org/building/) / Building Bye Laws (https://theconstructor.org/building/building-bye-laws/) / Standard Size of Rooms in Residential Building and their Locations Ads by Google Floor Plan Building Plan House Plan Design Knowledge of standard size of rooms and their location in a residential building is important for planning of residential construction project. The room sizes and their location provides spaces for movement, sunlight and natural air for residents. 1 of 9 4/21/2017 3:23 PM Sometime it is used as reception room and dining room and special occasions. Size of the drawing room should be determined by type of furniture to be used. comfortable and attractive place for sitting of family members and to receive friends and guests. Drawing room should be located in the middle of the building and should be connected to the front verandah and dining place.org/building/size-room-location-building/13269/ Standard Size of Rooms in Residential Building and their Locations 1. Generally.Standard Size of Rooms in Residential Building and their Locations https://theconstructor. 2 of 9 4/21/2017 3:23 PM . It should be well-lighted and ventilated. drawing or living room is the biggest room of the building so that it can be utilized for some ceremonial function in the house. Size of Drawing or Living Room: Drawing room or living room is a common. The bedroom should be located on the side of the direction of prevailing wind.Standard Size of Rooms in Residential Building and their Locations https://theconstructor. In bedrooms 9. Generally.5cubic meter per child space should be available and suitable allowance should be made for furniture. generally by the side of the drawing room.5 cubic meter per adult and 5. a bedroom should have an attached bathroom and water closet. The location should be such that the bedroom receives sunlight during morning hours. If good water supply and drainage system is available. 3 of 9 4/21/2017 3:23 PM . The minimum window area should be 1:10th of the floor area. Size of Bedrooms: Bedrooms should be so located that they are well ventilated and at the same time provide privacy. Size of Guest Room: Guest room should be well lighted and ventilated. Standard size of bedrooms may range from: 3000mm (10ft) X 3600mm (12ft) to 4200mm (14ft) X 4800mm (16ft) 3.org/building/size-room-location-building/13269/ Ads by Google Standard size of drawing room may range from: 4200mm (14ft) X 4800 mm (16ft) to 5400mm (18ft) X 7200mm (24ft) 2. It should be located on one side of the building. they should be located on the sides of the building so that at least one wall is exposed for good ventilation and lighting. the rear 4 of 9 4/21/2017 3:23 PM . If the frontage of the building is east then they are located in east also. The verandah also serves the purpose of a waiting room. Each house should have one front and rear verandah. It segregates the private apartment from the entrance area.Standard Size of Rooms in Residential Building and their Locations https://theconstructor. The veranda should shade the walls of the building during greater part of the day.org/building/size-room-location-building/13269/ Guest should be disconnected from inside of the house and should have separated bathroom and water closet. Size of Verandah: The best location for verandah is south and west. If space doesn’t permit. Standard size of guest rooms may be: 3000mm (10ft) X 3600mm (12ft) 4. For this it is necessary that it must not have openings of a height greater than 2:3rd of the floor width. Standard size of office room may be: 3000mm (10ft) X 3600mm (12ft) 6. Verandah have width ranging from 1800mm (6ft) to 3000mm (10ft) Verandah opening should always have a chajja projection for protection from sunlight and rain water. the dining room should be provided in rear of the drawing or living room and near the kitchen. Size of Office Room: Office rooms should be on one side of front verandah.Standard Size of Rooms in Residential Building and their Locations https://theconstructor. 5 of 9 4/21/2017 3:23 PM .org/building/size-room-location-building/13269/ verandah can be omitted. 5. In modern houses drawing room and dining room are combined to have a big room for special occasions. It should be connected with dining room and should have one approach from outside also. Size of bedrooms may range from: 3600mm (12ft) X 4200mm (14ft) to 4200mm (14ft) X4800mm (16ft) 7. disconnected from other rooms. Size of Kitchen: The kitchen should be provided in rear corner of the building but NE corner is the best. Size of Dining Room: Generally. For orthodox families dining room is kept separate. Sometimes an office room serves the purpose of guest room and vice versa. Sink should be provided for washing and sufficient number of shelves should also be provided. Size of Bathroom and WC: Now-a-days it has become common practice to provide attached bathroom and water closets with each bedroom. the kitchen should be so located that sun light should come in the morning hours. bath and WC should be provided in rear of the building separately so that the two can be used at a time. Good ventilation should be provided for bath and WC.org/building/size-room-location-building/13269/ If possible. Sometimes storeroom and kitchen are combined together. There should be two windows in a bathroom. when it is used most. The window space should be min. It is not attached to the bedrooms. kitchen serves the purpose of pantry. For ordinary building. Standard size of kitchen rooms may range from: 2500mm (8ft) X 3900mm (13ft) to 3000mm (10ft) X 3600mm (12ft) 8. Pantry: Pantry is a small room adjacent to dining room for keeping cooked food. Store Room: Store rooms should be located near the kitchen and should have sufficient number of racks. It should have windows for good ventilation and chimney for smoke escape.Standard Size of Rooms in Residential Building and their Locations https://theconstructor. Size of pantry may range from: 2500mm (8ft) X 3000mm (10ft) 10. Standard size of store room may range from: 2500mm (8ft) X 2500mm (8ft) to 3000mm (10ft) X 3000mm (10ft) 9. This is preferable only when good drainage and water supply is available. It should have sufficient numbers of cup-boards and shelves. of 15% of floor area. One for ventilation at a height of 6 of 9 4/21/2017 3:23 PM . if less space is available. com/pin/create/button/?url=https%3A%2F%2Ftheconstructor.org%2Fbuilding%2Fsize- room-location-building%2F13269%2F)  Twitter (https://twitter.Standard Size of Rooms in Residential Building and their Locations https://theconstructor. Sometimes ceiling height is kept low (2100mm or 7ft) and upper space is used for storage purpose Common sizes of bathroom and water closet may be: Bath and WC (combined): 1800mm X 1800mm to 1800mm X 2500mm Bathroom (separate): 1200mm X 1800mm WC (separate): 1200mm X 1200mm Read More: Height and Size Regulations for Rooms (https://theconstructor.com/sharer.com  (https://www.Org) room-location- building%2F13269%2F&media=&description=Standard Size of Rooms in Residential Building and their Locations) building%2F13269%2F) 7 of 9 4/21/2017 3:23 PM .com/intent/tweet?text=Standard Size of Rooms in Residential Building and their Locations&url=https%3A%2F%2Ftheconstructor.org%2Fbuilding%2Fsize-room-location-building%2F13269%2F&  via=theconstructor2) (https://plus.google.org%2Fbuilding%2Fsize-room-location- %2Ftheconstructor.org%2Fbuilding%2Fsize- /share?url=https %3A%2F room-location-building%2F13269%2F&title=Standard Size of Rooms in Residential Building and their  (https://pinterest.linkedin.com/shareArticle?mini=true&url=https%3A%2F%2Ftheconstructor.org%2Fbuilding%2Fsize.org/building/size-room-location-building/13269/ 2000mm above outside ground level and another at usual low level with frosted glass shutters for admitting light and maintaining privacy.org/building/building-bye-laws/height- size-regulations-for-rooms/5116/) T&C Apply SHARE  Facebook (https://www. Locations&source=TheConstructor.facebook.php?u=https%3A%2F%2Ftheconstructor. .org Navins Estimation and ESTIMATION SETTING OUT A Apartment for. Ad ArcelorMittal Rails theconstructor.org Ad aamphaa.....com theconstructor.org theconstructor. BUILDING.. Ad Navin's Hillview Avenue theconstructor..org/building/size-room-location-building/13269/ Rail Vastu Shastra Modular Kitchen BUILDING Manufacturer For Building..Standard Size of Rooms in Residential Building and their Locations https://theconstructor... Email Subscribe! POPULAR CATEGORIES 8 of 9 4/21/2017 3:23 PM . Calculation of.org  Search … Subscribe to our Newsletter Subscribe to Civil Engineering Updates and join other Civil Engineers. METHODS OF..org theconstructor.. ORIENTATION. org/concrete/special-concrete/) Structural Engineering (https://theconstructor.org/structures/bridges/) Building Materials (https://theconstructor.org/practical-guide/reinforcement-practical-guide/) Repair/Protection Guide (https://theconstructor.Standard Size of Rooms in Residential Building and their Locations https://theconstructor.org/concrete/crack/) Concrete Technology (https://theconstructor.org/)  About Us (https://theconstructor.org/contact-us/)  Privacy Policy (https://theconstructor.org/practical-guide/material-testing/) Mix Design Guide (https://theconstructor.org/practical-guide/work-procedure/)  Home (https://theconstructor.org/practical-guide/material-testing/concrete-testing/) Tips (https://theconstructor.org/geotechnical/) How To Guide (https://theconstructor.org/construction/) Construction Management (https://theconstructor.org/practical-guide/) Material Testing Guide (https://theconstructor.org/tips/) Work Procedures (https://theconstructor.org/building/building-tips/) Concrete Admixtures (https://theconstructor.org/surveying/) Tests on Concrete (https://theconstructor.org/building/building-material/) Building Technology (https://theconstructor.org/building/) Building Tips (https://theconstructor.org/privacy-policy/) Copyright 2015 The Constructor .Civil Engineering Home    (https://twitte (https://w (https: /theconstructo /TheConst /+Thec 9 of 9 4/21/2017 3:23 PM .org/earthquake/) Foundation Design (https://theconstructor.org/construction/const-management/) Construction Project (https://theconstructor.org/practical-guide/repairprotection-guide/) Special Concrete (https://theconstructor.org/concrete/) Construction (https://theconstructor.org/geotechnical/foundations/pile/) Reinforcement Guide (https://theconstructor.org/structural-engg/) Surveying (https://theconstructor.org/concrete/admixture/) Concrete Crack Repair (https://theconstructor.org/construction/project/) Earthquake Engineering (https://theconstructor.org/practical-guide/mix-design-practical-guide/) Pile Foundation (https://theconstructor.org/geotechnical/foundations/) Geotechnical Engineering (https://theconstructor.org/building/size-room-location-building/13269/ Bridges (https://theconstructor.org/concrete/crack/repair/) Concrete Cracks (https://theconstructor.org/structural-engg/foundation-design/) Foundation Engineering (https://theconstructor.org /about/)  Contact Us (https://theconstructor.
Copyright © 2024 DOKUMEN.SITE Inc.