SPP2014.06.0 ReleaseNotes

June 3, 2018 | Author: AdeL.Tanizar | Category: Operating System, Central Processing Unit, Microsoft Windows, Bios, Operating System Technology


Comments



Description

HPService Pack for ProLiant 2014.06.0 Release Notes First Published: June 2014 Last Updated: June 2014 HP Service Pack for ProLiant 2014.06.0 Release Notes Legal and notice information © Copyright 2014 Hewlett-Packard Development Company, L.P. Revision History: This document is the original version published June, 2014. Future revisions will be noted here. Change bars on the right-side of the content will indicate any additions and changes. Supersedes History Initial Release Effective Date June 2014 2 HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Table of Contents Overview ....................................................................................................................................................... 4 Summary of Changes .................................................................................................................................... 4 Release Summary .................................................................................................................................. 4 Fixes ...................................................................................................................................................... 5 Enhancements....................................................................................................................................... 5 Components Changes ........................................................................................................................... 5 Compatibility ......................................................................................................................................... 6 Support.................................................................................................................................................. 6 Operating Systems ........................................................................................................................................ 7 Supported Operating Systems .............................................................................................................. 7 Additional Information for using the SPP on Linux Operating Systems................................................ 8 Additional Information for using the SPP on VMware Operating Systems .......................................... 8 Prerequisites ................................................................................................................................................. 9 Component Prerequisites ..................................................................................................................... 9 Deployment Instructions .............................................................................................................................. 9 General.................................................................................................................................................. 9 Using a PXE Server to Deploy Components from the full SPP ISO over a network ............................ 10 HP SUM ............................................................................................................................................... 12 Known Limitations ...................................................................................................................................... 13 Additional Resources .................................................................................................................................. 14 Web Experience .................................................................................................................................. 14 Hot Fixes.............................................................................................................................................. 15 SPP Supplements ................................................................................................................................ 16 Component Release Notes ......................................................................................................................... 17 3 HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Overview HP Service Pack for ProLiant (SPP) is a comprehensive systems software and firmware solution delivered as a comprehensive ISO. This solution uses HP Smart Update Manager (HP SUM) as the deployment tool and is tested on all supported HP ProLiant servers including the HP ProLiant Gen8 servers. The SPP is delivered an ISO image as documented in the following table: Product Name Comment Note: The full SPP is delivered as an ISO file and no longer delivered as a Zip file. HP Service Pack for ProLiant Full SPP ISO Bootable ISO Filename: SPP2014060.2014_0618.4.iso Update recommendation: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version. Supersedes: HP Service Pack for ProLiant 2014.02.0(B) Summary of Changes Release Summary This summary of this SPP release is: This SPP is intended for use with HP OneView 1.10 and other supported Solutions from HP. Added support for:  HP FlexFabric 20Gb 2-port 630FLB Adapter  HP FlexFabric 20Gb 2-port 630M Adapter Contains:  HP BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 4/8Gb 20-port and 8Gb 24-port FC Edition Component v4.20(b)  HP Smart Update Manager v6.4.1 Important Notes:  This is the last SPP release to support G5 generation and earlier servers.  This is the final SPP release that will contain support for Red Hat Enterprise Linux 5. Future SPP releases will not contain support for Red Hat Enterprise Linux 5 HP | Service Pack for ProLiant 2014.06.0 4 HP Service Pack for ProLiant 2014.06.0 Release Notes Fixes The SPP was updated to address SSL/TLS MITM Vulnerability CVE-2014-0224 http://www.openssl.org/news/secadv_20140605.txt Enhancements The following lists of firmware and software components are new additions to the SPP: Added Firmware/Software Windows  HP ProLiant Converged Network Utility for Windows Server 2008  HP ProLiant Converged Network Utility for Windows Server x64 Editions  Online ROM Flash Component for Windows - HP ProLiant XL220a Gen8 v2 (P94) Servers Linux  HP ProLiant Converged Network Utility for Linux x86_64  HP ProLiant Converged Network Utility for Linux x86  Online ROM Flash Component for Linux - HP ProLiant XL220a Gen8 v2 (P94) Servers VMware  Online ROM Flash Component for VMware ESXi - HP ProLiant XL220a Gen8 v2 (P94) Servers  HP Firmware Flash for Emulex Fibre Channel Host Bus and Converged Network Adapters - VMware 5.0/5.1  HP Firmware Flash for Emulex Fibre Channel Host Bus and Converged Network Adapters for VMware vSphere 5.5  HP Firmware Flash for QLogic Fibre Channel Host Bus Adapters – Vmware  HP Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 5.5 For a complete list of components on the ISO, see the contents report on the ISO or the SPP documentation page. Driver Update Disks (DUD) for Linux DUDs for the following controllers for all Red Hat and SUSE supported operating systems can be found in the ‘DUD’ directory at the root of the ISO.  HP Dynamic Smart Array SATA RAID Controller  HP Smart Array B110i SATA RAID Controller  HP ProLiant Smart Array Controller Components Changes 5 Critical Components: HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes The following components are considered to be critical updates that released with this SPP. If a component is marked “critical” and was initially released with a previous version of the SPP, it will not be listed here. Please see the SPP Contents Report for a complete list of critical components. New critical components for Systems running a supported version of Windows:     HP BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 4/8Gb 20-port and 8Gb 24-port FC Edition Component for Windows HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server 2008 HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows 2008 x64 Editions HP ProLiant Dynamic Smart Array RAID Controller Driver for Microsoft Windows Server 2012 and Microsoft Windows 2012 R2 x64 Editions New critical components for Systems running a supported version of Linux:  HP BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 4/8Gb 20-port and 8Gb 24-port FC Edition Component for Linux Compatibility HP SUM and all components delivered in this Service Pack for ProLiant are tested together and meet the dependencies of the other components in the Service Pack for ProLiant. Systems using software and firmware components delivered with the following products should be able to easily migrate to this SPP: Product Version Service Pack for ProLiant 2014.02.0(B) 2013.09.0(C) Note: When migrating directly from an older version of the SPP to the latest, please review the release notes for the versions being skipped to be aware of changes that have occurred during those releases. Support HP supports each SPP version for 12 months. Customers may choose to update to the current SPP from a previous SPP version. This is acceptable as long as the earlier version is within current version’s 12 month support period. This means that customers may directly update their SPP by skipping intermediate releases within the 12 month support period. See the table in the Compatibility section for details on the components contained in earlier SPPs that can migrate to this SPP. The end of a support period can be determined by the version number of the release. For example, if SPP 2013.02.0 is currently installed, support for it would end the last day of February, 2014. This is based on version 2013=year, 02= month, 0=full release id number. Sometimes it is necessary to release an SPP with a version that would have less than 12 months of support per the information noted above. In these cases, use the table below to determine support periods: HP | Service Pack for ProLiant 2014.06.0 6 HP Service Pack for ProLiant 2014.06.0 Release Notes SPP Version End of Support Period 2014.06.0 June 30, 2015 2014.02.0(B) February 28, 2015 2013.09.0(C) September 30, 2014  IMPORTANT: Note the “End of Support Period” dates in the table above. For example, if SPP 2013.09.0(C) is installed, support for that SPP ends on September 30, 2014. Upgrading to a newer SPP would be required to continue to receive SPP support. Operating Systems Supported Operating Systems The following operating systems are supported for system software and firmware support:                     Microsoft Windows Server 2012 R2 Microsoft Windows Server 2012 - All Editions Microsoft Windows Server 2012 Essentials Microsoft Windows Small Business Server 2011 Standard and Essentials Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008 R2 Foundation Edition Microsoft Windows HPC Server 2008 R2 Microsoft Windows Server 2008 x64 - All Editions Microsoft Windows Server 2008 x64 - Server Edition Microsoft Windows Server 2008 x64 - Server Core Edition Microsoft Windows Server 2008 W32 - All Editions Microsoft Windows Server 2008 W32 - Server Edition Microsoft Windows Server 2008 W32 - Server Core Edition Microsoft Windows Server 2008 Foundation Edition Red Hat Enterprise Linux 6 Server (x86-64) Red Hat Enterprise Linux 6 Server (x86) Red Hat Enterprise Linux 5 Server (x86-64) Red Hat Enterprise Linux 5 Server (x86) SUSE LINUX Enterprise Server 11 (AMD64/EM64T) SUSE LINUX Enterprise Server 11 (x86) Firmware-only Support:    7 VMware vSphere 5.5 and 5.5 U1 VMware vSphere 5.1 U2 VMware ESXi 5.0 U3 HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes      VMware ESXi 4.1 U2, U3 (offline only) Novell Open Enterprise Server (Linux) (offline only) Novell SUSE Open Linux (offline only) Oracle Enterprise Linux (offline only) Debian Linux (all releases) (offline only) For more information on HP Operating Systems and Virtualization Software Support for HP ProLiant Servers, please visit our OS Support Site at: www.hp.com/go/ossupport. Additional Information for using the SPP on Linux Operating Systems The following operating systems are supported for system software, drivers, and firmware support:    Red Hat Enterprise Linux 5.10 and 5.9 Red Hat Enterprise Linux 6.5 and 6.4 SUSE LINUX Enterprise Server 11 SP3 and SP2 Please refer to the following links for Technical Exception matrices for minimum OS support Red Hat Enterprise Linux http://h18004.www1.hp.com/products/servers/linux/supportmatrix/rhel/exceptions/rhel-exceptions.html SUSE LINUX Enterprise Server http://h18004.www1.hp.com/products/servers/linux/supportmatrix/sles/exceptions/sles-exceptions.html Using the SPP on a supported Linux operating system offers the following choices:    Using the software and firmware provided in the SPP. Using the firmware provided in the SPP and getting the software from the Software Delivery Repository (SDR) at http://downloads.linux.hp.com/SDR. Using the firmware provided in the SPP, the software utilities provided in the SPP or SDR, and getting the “indistro” drivers from the operating system distribution. Additional Information for using the SPP on VMware Operating Systems The following operating systems are supported for firmware support:     VMware vSphere 5.5 VMware vSphere 5.1 U2 VMware ESXi 5.0 U3 VMware ESXi 4.1 U2, U3 (offline only) The SPP can deploy firmware to a system running a supported VMware operating system in an online mode. See the Summary of Changes section for the list of supported online firmware. Since the VMware drivers are not part of the SPP, they can be obtained from the VMware base image or HP Custom image, available from the HP download page. Drivers added to the HP Custom image are available at HP vibsdepot. For a consolidated recipe of firmware and driver support, please review the VMware FW and Software Recipe document. HP | Service Pack for ProLiant 2014.06.0 8 HP Service Pack for ProLiant 2014.06.0 Release Notes The HP ProLiant Gen8 servers require the use of an HP custom image of HP ProLiant. This image contains the network and storage drivers that are required to install on the HP ProLiant Gen8 servers. Because the current VMware images do not contain the latest drivers, they cannot be used to install on HP ProLiant Gen8 servers. This same requirement was in place for the HP ProLiant Blade System servers. To determine support for these OS’s, see the HP ProLiant Server VMware Support Matrix at: http://h18004.www1.hp.com/products/servers/vmware/supportmatrix/hpvmware.html Prerequisites Component Prerequisites Some components have prerequisites. Check the individual components for their prerequisites. Deployment Instructions General Follow these steps to install the components found on this SPP: 1. Download the SPP 2014.06.0.iso file from the SPP download page, www.hp.com/go/spp/download. 2. Determine how to access the data on the ISO – bootable USB key, mounted ISO, mounted DVD, etc. Use the appropriate tool to obtain the ISO in the desired format. Note: The HP USB Key Utility for Windows version 1.7.0.0 or later can be used to put this SPP on a bootable USB key and is also found on the SPP ISO. 3. Determine how to initiate deployment to the targets using the SPP – Offline mode or Online mode: a. Online mode - Runs on a Windows® or Linux hosted operating system 4. NOTE: online firmware update is only supported on a remote VMware host b. Offline mode - Server boots to the SPP ISO (Bootable ISO only) i. Automatic mode - Firmware components update without interaction ii. Interactive mode - Onscreen instructions guide the user to update firmware components Initiate deployment. To initiate deployment in Online mode:  Go directly to the HP SUM deliverable to launch it: o Windows: \hp\swpackages\hpsum.exe o Linux: /hp/swpackages/hpsum  For VMware hosts, select the host to update as a remote target. Online firmware update on a VMware host requires the HP Insight Management WBEM providers to be installed on the VMware host. For information, see the HP SUM User Guide and HP ProLiant Best Practices Implementers Guide. HP | Service Pack for ProLiant 2014.06.0 9 HP Service Pack for ProLiant 2014.06.0 Release Notes   To review the EULA, locate Start.htm which is found in the root of the ISO. Open the html file and follow the instructions on the screen. To initiate deployment in Offline mode:  Boot the server to the SPP using one of the supported methods including mounting the ISO or DVD or using a bootable USB key.  Select either Automatic mode or Interactive mode.  If Automatic mode is selected, the firmware will be automatically updated on the server without any further interaction.  If Interactive mode is selected, follow the instructions on the screen.  Select the Firmware Update option on the screen to start HP SUM Using a PXE Server to Deploy Components from the full SPP ISO over a network Follow these steps to use a PXE server to deploy components from the full SPP ISO over a network. Note: The files needed to configure the menu system for use with a PXE server can be found in the pxe directory on the full SPP ISO. Prerequisites The following is required before proceeding with the configuration:  The user must have a good working knowledge of PXE and TFTP.  A network with a DHCP server on it.  A TFTP server configured on the same network as the DHCP server.  A network file server hosting the ISO images and can be accessed by a PXE booted system.  PXELinux (http://syslinux.zytor.com/wiki/index.php/PXELINUX) The use of a Linux TFTP server and the TFTP package (http://www.kernel.org/pub/software/network/tftp) is assumed. Other TFTP servers should work similarly. Setup Before proceeding with the configuration, ensure that the TFTP server and PXELinux configuration are setup and configured properly. To set up PXE boot for the SPP: 1. Copy the SPP ISO image to the network file system, and note its location. NFS and Windows® file shares are supported. 2. For this example, the NFS and path to the ISO image used is 192.168.0.99/path/to/spp/image/SPP2014060.2014_####.##.iso. Test the network file system to ensure that is accessible before proceeding. 3. The /system directory of the ISO image will need to be accessed, either by burning the ISO image, mounting the ISO image, or extracting it using a third-party tool. 4. Copy all the files from the /system directory of the ISO image to your TFTP server so that it is accessible by the TFTP software. 10 Configuring PXELINUX Follow these steps to configure PXELINUX: HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes 1. Using the isolinux.cfg file from the /system/ directory of the ISO as a guide, copy the labeled targets to the PXELinux configuration file. The entire file does not need to be included: label sos MENU LABEL Automatic Firmware Update Version 2014.06.0 kernel hpboot_v.c32 append vmlinuz initrd=initrd.img media=cdrom rw root=/dev/ram0 ramdisk_size= init=/bin/init loglevel=3 ide=nodma ide=noraid nopat pnpbios=off vga=791 splash=silent hp_fibre showopts noexec32=off numa=off nox2apic TYPE=AUTOMATIC AUTOPOWEROFFONSUCCESS=no AUTOREBOOTONSUCCESS=yes label vsos MENU LABEL Interactive Firmware Update Version 2014.06.0 kernel hpboot_v.c32 append vmlinuz initrd=initrd.img media=cdrom rw root=/dev/ram0 ramdisk_size= init=/bin/init loglevel=3 ide=nodma ide=noraid nopat pnpbios=off vga=791 splash=silent hp_fibre showopts noexec32=off numa=off nox2apic TYPE=MANUAL AUTOPOWEROFFONSUCCESS=no label sos_poweroff MENU HIDE Automatic & POWEROFF Firmware Update Version 2014.06.0 kernel hpboot_v.c32 append vmlinuz initrd=initrd.img media=cdrom rw root=/dev/ram0 ramdisk_size= init=/bin/init loglevel=3 ide=nodma ide=noraid nopat pnpbios=off vga=791 splash=silent hp_fibre showopts noexec32=off numa=off nox2apic TYPE=AUTOMATIC hp_poweroff 2. Replace the lines “kernel hpboot_v.c32” with “kernel vmlinuz”. 3. Remove vmlinuz from the append line. Note: The paths to files on the TFTP server are vmlinuz and initrd.img. They must be modified to include any directories or naming conventions that are on the TFTP server. 4. Replace “media=cdrom” with “media=net” on the append line 5. Specify the ISO image path. For the PXE booted server to find the ISO Image, add the ISO Image path to the append line in the PXELINUX configuration file. Add the following arguments: iso1=nfs://192.168.0.99/path/to/spp/image/SPP2014060.2014_####.##.iso iso1mnt=/mnt/bootdevice The iso1 parameter helps the PXE booted SPP locate the ISO image. The iso1mnt parameter tells the PXE booted FWDVD where the iso1 image must be mounted. The final configuration file must be similar to the following example: label sos MENU LABEL Automatic Firmware Update Version 2014.06.0 kernel vmlinuz append initrd=initrd.img media=net rw root=/dev/ram0 ramdisk_size= init=/bin/init loglevel=3 ide=nodma ide=noraid nopat pnpbios=off vga=791 splash=silent hp_fibre showopts noexec32=off numa=off nox2apic TYPE=AUTOMATIC AUTOPOWEROFFONSUCCESS=no AUTOREBOOTONSUCCESS=yes iso1=nfs://192.168.0.99:/path/to/spp/image/SPP2014060.2014_####.##.iso iso1mnt=/mnt/bootdevice label vsos MENU LABEL Interactive Firmware Update Version 2014.06.0 kernel vmlinuz HP | Service Pack for ProLiant 2014.06.0 11 HP Service Pack for ProLiant 2014.06.0 Release Notes append initrd=initrd.img media=net rw root=/dev/ram0 ramdisk_size= init=/bin/init loglevel=3 ide=nodma ide=noraid nopat pnpbios=off vga=791 splash=silent hp_fibre showopts noexec32=off numa=off nox2apic TYPE=MANUAL AUTOPOWEROFFONSUCCESS=no iso1=nfs:// 192.168.0.99:/path/to/spp/image/SPP2014060.2014_####.##.iso iso1mnt=/mnt/bootdevice label sos_poweroff MENU HIDE Automatic & POWEROFF Firmware Update Version 2014.06.0 kernel vmlinuz append initrd=initrd.img media=net rw root=/dev/ram0 ramdisk_size= init=/bin/init loglevel=3 ide=nodma ide=noraid nopat pnpbios=off vga=791 splash=silent hp_fibre showopts noexec32=off numa=off nox2apic TYPE=AUTOMATIC hp_poweroff iso1=nfs:// 192.168.0.99:/path/to/spp/image/SPP2014060.2014_####.##.iso iso1mnt=/mnt/bootdevice Additional ISO images can be added by specifying the additional iso# and iso#mnt arguments, for example, iso2=/path/to/iso2.iso iso2mnt=/mnt/iso2. Supported network file systems The following network file systems are supported for use with PXE booting: NFS: iso1=nfs://192.168.0.99/path/to/spp/image/ SPP2014060.2014_####.##.iso iso1mnt=/mnt/bootdevice NFS volumes are mounted with the following options:  -o ro  nolock The mount options can be explicitly set with the iso#opts parameter iso1opts="rsize=32768,ro,nolock" Windows® operating systems: iso1=smbfs://192.168.0.99/share/path/to/ spp/image/ SPP2014060.2014_####.##.iso iso1mnt=/mnt/bootdevice Windows® operating systems with login credentials: iso1=smbfs://user:[email protected]/share/path/to/ spp/image/ SPP2014060.2014_####.##.iso iso1mnt=/mnt/bootdevice Once these steps have been completed, the SPP components are ready to be deployed using the PXE boot functionality. 12 HP SUM Note: Please review the latest HP SUM Release Notes for additional information including known limitations on HP SUM. HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Known Limitations HP-CNU is unsupported in the RHEL5.xx series but the component HP-CNU is listed as available to install with RHEL 5.10 The HP-CNU component should be deselected prior to installation. Kmod-hpsa driver is getting listed though the hardware is unavailable in RHEL 6 The Kmod-hpsa driver is listed as available for install even when the hardware is unavailable in RHEL 6. Deselect the driver prior to installation. HP Qlogic qlcnic Drivers for SUSE 11 are listed during inventory on RHEL5 HP Qlogic qlcnic drivers for SUSE 11 are listed during inventory on RHEL 5 systems. Deselect the SUSE components prior to installation. Emulex Fibre Channel Host Bus firmware fails to rewrite on VMware The Emulex Fibre Channel Host Bus firmware will fail to rewrite the same version and will display the error message ‘update returned an error’. On a rewrite, the component can be successfully installed using ‘force’ in standalone mode. Unable to install HP 512MB flash backed write cache for B-series smart arrays When performing online flashing for the HP 512MB flash backed write cache for B-series smart arrays, the component fails to install. The component will display as ready for installation and is selected by default; however, when online flashing occurs, the component displays the message ‘update returned an error’. The HP ProLiant DL380p Gen8 Server ROM initial installation fails on ESXi 5.1 U2 The HP ProLiant DL380p Gen8 Server ROM will fail on the initial installation on ESXi 5.1 U2. The ROM will successfully install when run a second time. Smart Array FW displays the message ‘Update Returned an Error’ when installing on Windows 2012 Domain Controller The Smart Array FW may display the message ‘Update Returned an Error’ during the initial install on Windows 2012 Domain Controller. If HP SUM displays this message, reboot the machine to determine if the firmware installed correctly. If the firmware failed on initial installation, it will install correctly during the second pass. The HPCISSS3 driver will override the CISSS2 driver when both are selected for installation When installing drivers on the HP SAS/SATA Smart Array and both the HPCISSS3 and the HPCISSS2 drivers are selected, the CISSS3 driver overrides the CISSS2 driver. The CISSS2 driver will show as ready for installation and indicate the installation occurred; however, when HP SUM is re-launched the driver displays as ready for installation and the CISSS2 driver was not installed. SPP Boot environment change HP | Service Pack for ProLiant 2014.06.0 13 HP Service Pack for ProLiant 2014.06.0 Release Notes Beginning with the SPP 2014.02.0 the boot environment has been changed. The SPP iso contains signed parts as required in order to work with the UEFI bootloader. Please note that this change will no longer allow for ‘multiboot’ setups on a device such as a USB key. Offline BIOS updates are not supported for HP Brocade PCIe Fibre Channel Host Bus Adapters and for Brocade Fibre Channel HBAs for c-Class BladeSystems HP Service Pack for ProLiant Offline BIOS updates for HP Brocade PCIe Fibre Channel Host Bus Adapters and Brocade Fibre Channel HBAs for c-Class BladeSystem are not supported. When booting directly into the HP Service Pack for ProLiant (SPP) and attempting to update the BIOS on HP Brocade HBA's (an offline update), BIOS updates for HP Brocade HBA's and mezzanine cards are not available. An intermittent deployment error is displayed when flashing A deployment error can be observed intermittently when flashing, usually on an HP ProLiant BL465 Gen8 with Windows 2008 SP2 32bit installed. The error is intermittent but the components have successful installed. HP ProLiant DL385p Gen8 (A28) Online ROM flash component isn’t detected on RHEL 5.10 32bit The HP ProLiant DL385p Gen8 (A28) Online ROM flash component isn’t detected on RHEL 5.10 32bit. The components for the DL385p are 64bit only and therefore won’t display on a 32bit system. Additional Resources Web Experience Web Page Information/Description Resources on the SPP Download Page: www.hp.com/go/spp/download Hot Fixes and Customer Advisory Listing Information on Hot Fixes and their associated Customer Advisories (CA), Resolved CAs, and Open CAs is available online by clicking the “Hot Fixes and Advisories” button on the SPP Download page. This web page will be updated on a regular basis as new information becomes available. SPP Release Archive Downloads and Hot Fixes and CAs for all versions of the SPP within the one year support window are available for access here. If there are any Supplements corresponding with any SPP on this page, each Supplement can be downloaded from the link with the Supplement’s name in the SPP highlights section of the corresponding SPP. HP Smart Update Video Library A series of videos is available that offers information about the SPP, HP SUM, and firmware best practices including how you can plan and perform updates in your environment. The videos can be found online by clicking the “Smart Update Video Library” link on the SPP Download page or using the vanity URL, http://www.hp.com/go/smartupdate/video. SPP Supplement Download SPP Supplements can be downloaded from the link with the Supplement’s name in the SPP highlights section. HP | Service Pack for ProLiant 2014.06.0 14 com/. contains the software and firmware contents of the SPP. It provides a way for the user to deploy the software components of the SPP using native Linux tools.0 Release Notes Web Page Information/Description Resources on the SPP Documentation Page: www. Hot Fixes Hot Fixes and their associated Customer Advisories are released between SPP releases. Find the entry for the SPP and select the link to the CA tab for that SPP. version number. Hot fixes are picked up in the following SPP release.06. If you are looking for Hot Fixes for SPPs other than the latest one. Resources on HP SUM Documentation Page: http://www. is a one-stop repository that provides access to HP developed bundles along with device drivers that are part of the HP Customized VMware images. which is available from the SPP Download page.com/go/spp/download. Reference the HP SUM Release Notes for the most current information on HP SUM. The Hot Fixes and the Customer Advisories for the latest SPP can be found by selecting the “Hot Fixes & Advisories” tab on the SPP Download page.hp. has instructions for Scripted Deployment and other advanced topics. and offers Troubleshooting instructions.hp.linux. www. http://downloads.com/SDR/. http:/vibsdepot.06. These documented Hot Fixes are supported as part of the SPP throughout the SPP support period. you will be able to review the Customer Advisory to determine if the Hot Fix applies to your configuration and determine which component(s) you need to download.com/go/spp/documentation SPP Server Support Guide The SPP Server Support Guide lists all of the components included in the SPP and the servers that they are supported on and is available online on the SPP Documentation page. and the associated filename and is available online on the SPP Documentation page. HP SUM User Guide The HP SUM User Guide describes the User Interface in detail. On this page. VMware SDR . 3. Click the Download button to download the component to a repository of your choice. and known limitations for HP SUM.HP Service Pack for ProLiant 2014. To update your configuration with a Hot Fix: 1. enhancements.hp. Hot Fix components are tested against all SPP releases in the support window.com/go/hpsum/documentation HP SUM Release Notes The HP SUM Release Notes provides information including fixes. go to the SPP Release Archive tab.hp.hp. www. Click the grey + expander to the left of the Hot Fix CA to expand the list of associated downloadable component(s). Deploy it using HP SUM. Linux SDR The Linux SDR.hp.vibsdepot. There are also links to the VMware recipe documents that are associated with an SPP.0 15 . SPP Contents Report The SPP Contents Report documents all of the software and firmware on this SPP by the product name.vibsdepot The VMware SDR .com/go/spp/download. HP | Service Pack for ProLiant 2014. 2. It may include support for a new operating system update or functionality that is not included in the SPP but works with the components in the SPP. (http://www. Support for SPP Supplements are included as part of the associated SPP’s support period.0 Release Notes SPP Supplements An SPP Supplement is a bundle containing software and/or firmware components with HP SUM as the deployment tool. Each SPP Supplement´s version number will match the version of its corresponding SPP.HP Service Pack for ProLiant 2014. 16 HP | Service Pack for ProLiant 2014.06.0 . To see if a Supplement is available.hp. There are no Supplements associated with this SPP at the time this document was published. If the Supplement´s contents include Linux components. the components will also be available on the SDR. The software and firmware included in the Supplement will provide support for functionality that is required outside a normal SPP release cycle. Supplement Release Notes will be available and will include information on the components in the bundle.com/go/spp/download).hp. please check the SPP Download (http://www. the functionality of the SPP Supplement supporting new operating system support content is included in the next available SPP.06.com/go/spp/download).com/go/spp/documentation). The Release Notes can be found on the SPP Information Library site. Once released. Supplements allow HP to deliver support when it is needed so customers do not have to wait on a full SPP´s availability. SPP Supplements can be downloaded from the SPP Information section on the SPP Download (http://www.hp. SAS Storage Disk Firmware .25 (Critical) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL260c G5 System ROM .0 .HP Service Pack for ProLiant 2014.Lights-Out Management Firmware .Storage Fibre Channel Driver .System Management BIOS .Storage Controller Driver .Storage Fibre Channel Firmware .System ROM Driver .USB Driver .06.HP ProLiant BL260c G5 (I20) Servers Version: 2010.Storage Driver .Lights-Out Management Software .Network Driver .10.Storage Controller Software .Blade Infrastructure Firmware .System ROM Top Online ROM Flash Component for Linux .Power Management Firmware .Storage Tape Software .System Management Driver .0 Release Notes Component Release Notes BIOS .Network Software .I20 17 Release Date: 10/25/2010 HP | Service Pack for ProLiant 2014.Lights-Out Management Driver .Chipset Driver .Video Firmware .Storage Controller Firmware .Storage Fibre Channel HBA Software .Network Firmware .06.Storage Tape Driver .SATA Storage Disk Firmware . or other unpredictable system behavior.HP Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None 18 Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. Intel Xeon 5200-series. kernel panic. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue. This issue affects platforms utilizing Intel Xeon 5100-series. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. blue screen. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. and Intel Xeon 5400-series processors. blue screen. this System ROM upgrade is considered a critical fix.06. HP strongly recommends immediate update to firmware revisions with required critical fixes.0 .06.0 Release Notes Last Recommended or Critical Revision: 10/25/2010 Previous Revision: 04/26/2010 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. Due to the potential severity of the issue addressed in this revision of the System ROM. or other unpredictable system HP | Service Pack for ProLiant 2014. 0x00000000)". Intel Xeon 5300-series. kernel panic. 02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. Intel Xeon 5200-series. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL280c G6 System ROM . This issue is not unique to HP ProLiant servers and could impact any system using affected processors. Due to the potential severity of the issue addressed in this revision of the System ROM. 0x00000000)".07. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue.06.www2. This issue affects platforms utilizing Intel Xeon 5100-series.HP ProLiant BL280c G6 (I22) Servers Version: 2013. HP strongly recommends immediate update to firmware revisions with required critical fixes. this System ROM upgrade is considered a critical fix. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Intel Xeon 5300-series.0 Release Notes behavior. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.0 . Known Issues: None Online ROM Flash Component for Linux . and Intel Xeon 5400-series processors.HP Service Pack for ProLiant 2014.06.I22 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 19 12/02/2012 Firmware Dependencies: HP | Service Pack for ProLiant 2014. have Intel Hyperthreading enabled.0 Release Notes None Enhancements/New Features: None. Due to the potential severity of the issue addressed in this revision of the System ROM. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.HP Service Pack for ProLiant 2014. receive spurious interrupts or cause a network disconnect.06. or machine check exceptions or other unpredictable system behavior. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.06.www2. While all processors supported by this server have this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.2. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.0 20 . Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Addressed an issue with the Intel Xeon Processor X5675. As a result of this issue. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. and IRQ Balancing enabled in the Operating System.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: HP | Service Pack for ProLiant 2014. to be affected by this issue the server must be operating in a virtualized environment.com/bizsupport/TechSupport/Document. such as Linux RedHat 6. general protection faults. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. and have a guest OS utilizing 32-bit PAE Paging Mode. this System ROM upgrade is considered a critical fix. This issue does not impact any processors that are not listed above. Intel Xeon Processor X5690.hp. software may lose interrupts. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. As a result of this issue. to be affected by this issue the server must be operating in a virtualized environment.25 (Critical) Important Note! Important Notes: None Deliverable Name: 21 HP ProLiant BL2x220c G5 System ROM .HP ProLiant BL2x220c G5 (I19) Servers Version: 2010.I19 Release Date: HP | Service Pack for ProLiant 2014. receive spurious interrupts or cause a network disconnect.0 Release Notes None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.06. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Known Issues: None Online ROM Flash Component for Linux . this System ROM upgrade is considered a critical fix. or machine check exceptions or other unpredictable system behavior.HP Service Pack for ProLiant 2014. Intel Xeon Processor X5690. such as Linux RedHat 6. have Intel Hyperthreading enabled. and have a guest OS utilizing 32-bit PAE Paging Mode. While all processors supported by this server have this issue. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.10. Due to the potential severity of the issue addressed in this revision of the System ROM. software may lose interrupts. This issue does not impact any processors that are not listed above.06. general protection faults. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 . Addressed an issue with the Intel Xeon Processor X5675. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.2. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and IRQ Balancing enabled in the Operating System. blue screen. Known Issues: None Fixes Important Notes: None Firmware Dependencies: 22 None Problems Fixed: HP | Service Pack for ProLiant 2014. 0x00000000)".0 . This issue affects platforms utilizing Intel Xeon 5100-series. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. this System ROM upgrade is considered a critical fix. kernel panic. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue.0 Release Notes 10/25/2010 Last Recommended or Critical Revision: 10/25/2010 Previous Revision: 04/26/2010 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. or other unpredictable system behavior. and Intel Xeon 5400-series processors.06.HP Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. Intel Xeon 5300-series. Intel Xeon 5200-series. HP strongly recommends immediate update to firmware revisions with required critical fixes.06. Due to the potential severity of the issue addressed in this revision of the System ROM. www2.06.06.0 . Known Issues: None Online ROM Flash Component for Linux . Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. This issue affects platforms utilizing Intel Xeon 5100-series. kernel panic. Due to the potential severity of the issue addressed in this revision of the System ROM.hp.07.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Intel Xeon 5300-series. 0x00000000)". A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.0 Release Notes Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. and Intel Xeon 5400-series processors. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL2x220c G6 System ROM .I26 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 23 Previous Revision: HP | Service Pack for ProLiant 2014. HP strongly recommends immediate update to firmware revisions with required critical fixes.HP ProLiant BL2x220c G6 (I26) Servers Version: 2013. blue screen. Intel Xeon 5200-series. or other unpredictable system behavior. this System ROM upgrade is considered a critical fix. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. software may lose interrupts. As a result of this issue.www2.06.06.com/bizsupport/TechSupport/Document. or machine check exceptions or other unpredictable system behavior. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. and IRQ Balancing enabled in the Operating System. have Intel Hyperthreading enabled.HP Service Pack for ProLiant 2014. this System ROM upgrade is considered a critical fix. receive spurious interrupts or cause a network disconnect. such as Linux RedHat 6. Addressed an issue with the Intel Xeon Processor X5675. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. general protection faults. to be affected by this issue the server must be operating in a virtualized environment. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. While all processors supported by this server have this issue. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This issue does not impact any processors that are not listed above. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.0 24 . This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.hp. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and have a guest OS utilizing 32-bit PAE Paging Mode. Intel Xeon Processor X5690. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.jsp?locale=en_US&objectID=c0283837 HP | Service Pack for ProLiant 2014.0 Release Notes 05/05/2011 Firmware Dependencies: None Enhancements/New Features: None. Due to the potential severity of the issue addressed in this revision of the System ROM.2. Intel Xeon Processor X5690. general protection faults. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. or machine check exceptions or other unpredictable system behavior. and IRQ Balancing enabled in the Operating System.2.0 25 . and have a guest OS utilizing 32-bit PAE Paging Mode.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. this System ROM upgrade is considered a critical fix. This issue does not impact any processors that are not listed above. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory HP | Service Pack for ProLiant 2014. such as Linux RedHat 6. receive spurious interrupts or cause a network disconnect. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.HP ProLiant BL2x220c G7 (I29) Servers Version: 2013.06. While all processors supported by this server have this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.06. have Intel Hyperthreading enabled.HP Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Due to the potential severity of the issue addressed in this revision of the System ROM.07. Known Issues: None Online ROM Flash Component for Linux . This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. software may lose interrupts. As a result of this issue. Addressed an issue with the Intel Xeon Processor X5675. to be affected by this issue the server must be operating in a virtualized environment.0 Release Notes 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. While all processors supported by this server have this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.hp. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL2x220c G7 System ROM .HP Service Pack for ProLiant 2014.www2. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.0 26 .com/bizsupport/TechSupport/Document. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Due to the potential severity of the issue addressed in this revision of the System ROM. HP | Service Pack for ProLiant 2014. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. This issue does not impact any processors that are not listed above.06. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. this System ROM upgrade is considered a critical fix. have Intel Hyperthreading enabled. or machine check exceptions or other unpredictable system behavior. and have a guest OS utilizing 32-bit PAE Paging Mode.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue with the Intel Xeon Processor X5675.0 Release Notes C02838375 available at the following link: http://h20000.I29 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. Intel Xeon Processor X5690. to be affected by this issue the server must be operating in a virtualized environment. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. general protection faults. 06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06. Due to the potential severity of the issue addressed in this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. such as Linux RedHat 6. software may lose interrupts.0 27 . software may lose interrupts.2. While all processors supported by this server have this issue. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. As a result of this issue.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. and IRQ Balancing enabled in the Operating System.com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.www2. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. and have a guest OS utilizing 32-bit PAE Paging Mode. such as Linux RedHat 6. to be affected by this issue the server must be operating in a virtualized environment. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. have Intel Hyperthreading enabled. Addressed an issue with the Intel Xeon Processor X5675. and IRQ Balancing enabled in the Operating System.0 Release Notes Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. receive spurious interrupts or cause a network disconnect. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. this System ROM upgrade is considered a critical fix. or machine check exceptions or other unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This issue does not impact any processors that are not listed above. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. As a result of this issue. receive spurious interrupts or cause a network HP | Service Pack for ProLiant 2014.2. Intel Xeon Processor X5690. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. general protection faults. HP Service Pack for ProLiant 2014.06.0 Release Notes disconnect. Known Issues: None Online ROM Flash Component for Linux - HP ProLiant BL420c Gen8 (I30) Servers Version: 2014.02.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL420c Gen8 System ROM - I30 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Improved the power allocation logic for servers configured with Intel Xeon E5-2400 v2 series processors to more accurately determine the server's maximum power usage. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2400 v2 series processors than was necessary. With this revision of the System ROM, the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. This change does not impact servers configured with Intel Xeon E5-2400 series processors. HP | Service Pack for ProLiant 2014.06.0 28 HP Service Pack for ProLiant 2014.06.0 Release Notes Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2400 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: 29 Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2400 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Improved the power allocation logic for servers configured with Intel Xeon E5-2400 v2 series processors to more accurately determine the server's maximum power usage. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2400 v2 series processors than was necessary. With this revision of the System ROM, the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. This change does not impact servers configured with Intel Xeon E5-2400 series processors. Online ROM Flash Component for Linux - HP ProLiant BL460c (I15) Servers Version: 2011.05.02 (Critical) Important Note! Important Notes: 30 As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL460c System ROM - I15 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. This is normally seen as the system hanging during system boot without anything displayed to video. Once the system gets into this state, the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. Known Issues: 31 None Fixes HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. This is normally seen as the system hanging during system boot without anything displayed to video. Once the system gets into this state, the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux - HP ProLiant BL460c G5 (I23) Servers Version: 2011.05.02 (Critical) Important Note! Important Notes: 32 As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL460c G5 System ROM - I23 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. This is normally seen as the system hanging during system boot without anything displayed to video. Once the system gets into this state, the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. Known Issues: 33 None Fixes HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. This is normally seen as the system hanging during system boot without anything displayed to video. Once the system gets into this state, the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux - HP ProLiant BL460c G6/WS460c G6 (I24) Servers Version: 2013.10.01 (Optional) Important Note! 34 Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL460c G6 and WS460c G6 System ROM - I24 Release Date: 10/01/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 07/02/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed an issue where the system may experience a Blue Screen when booting Microsoft Windows 2003 with the 07/02/2013 revision of the System ROM. This issue only occurs with the 07/02/2013 revision of the System ROM and does not affect any previous revisions. Addressed an issue where Wake On LAN would not function properly with certain Networking devices. Known Issues: None Fixes Important Notes: 35 Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed an issue where the system may experience a Blue Screen when booting Microsoft Windows 2003 with the 07/02/2013 revision of the System ROM. This issue only occurs with the 07/02/2013 revision of the System ROM and does not affect any previous revisions. Addressed an issue where Wake On LAN would not function properly with certain Networking devices. Known Issues: None Online ROM Flash Component for Linux - HP ProLiant BL460c G7 (I27) Servers Version: 2013.07.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL460c G7 System ROM - I27 Release Date: 07/02/2013 Last Recommended or Critical Revision: 36 07/02/2013 HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Previous Revision: 12/03/2012 Firmware Dependencies: None Enhancements/New Features: None. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults, general protection faults, or machine check exceptions or other unpredictable system behavior. While all processors supported by this server have this issue, to be affected by this issue the server must be operating in a virtualized environment, have Intel Hyperthreading enabled, have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables, and have a guest OS utilizing 32-bit PAE Paging Mode. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM, this System ROM upgrade is considered a critical fix. Addressed an issue with the Intel Xeon Processor X5675, Intel Xeon Processor X5690, and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This issue does not impact any processors that are not listed above. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems, such as Linux RedHat 6.2, and IRQ Balancing enabled in the Operating System. As a result of this issue, software may lose interrupts, receive spurious interrupts or cause a network disconnect. Known Issues: None Fixes Important Notes: 37 Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults, general protection faults, or machine check exceptions or other unpredictable system behavior. While all processors supported by this server have this issue, to be affected by this issue the server must be operating in a virtualized environment, have Intel Hyperthreading enabled, have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables, and have a guest OS utilizing 32-bit PAE Paging Mode. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM, this System ROM upgrade is considered a critical fix. Addressed an issue with the Intel Xeon Processor X5675, Intel Xeon Processor X5690, and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This issue does not impact any processors that are not listed above. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems, such as Linux RedHat 6.2, and IRQ Balancing enabled in the Operating System. As a result of this issue, software may lose interrupts, receive spurious interrupts or cause a network disconnect. Known Issues: None Online ROM Flash Component for Linux - HP ProLiant BL460c/WS460c Gen8 (I31) Servers Version: 2014.02.10 (Optional) Important Note! 38 Important Notes: None HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Deliverable Name: HP ProLiant BL460c/WS460c Gen8 System ROM - I31 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Improved the power allocation logic for servers configured with Intel Xeon E5-2600 v2 series processors to more accurately determine the server's maximum power usage. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2600 v2 series processors than was necessary. With this revision of the System ROM, the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. This change does not impact servers configured with Intel Xeon E5-2600 series processors. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and HP | Service Pack for ProLiant 2014.06.0 39 HP Service Pack for ProLiant 2014.06.0 Release Notes QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot HP | Service Pack for ProLiant 2014.06.0 40 HP Service Pack for ProLiant 2014.06.0 Release Notes devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Improved the power allocation logic for servers configured with Intel Xeon E5-2600 v2 series processors to more accurately determine the server's maximum power usage. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2600 v2 series processors than was necessary. With this revision of the System ROM, the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. This change does not impact servers configured with Intel Xeon E5-2600 series processors. Online ROM Flash Component for Linux - HP ProLiant BL465c G1/BL465c G5/BL465c G6 (A13) Servers Version: 2011.05.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL465c G1/G5/G6 System ROM - A13 Release Date: 05/02/2011 41 Last Recommended or Critical Revision: 05/02/2011 HP | Service Pack for ProLiant 2014.06.0 0 Release Notes Previous Revision: 12/08/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.com/bizsupport/TechSupport/Document.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. HP | Service Pack for ProLiant 2014.hp.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: 42 Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).www2.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).hp.06.www2.0 .HP Service Pack for ProLiant 2014. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.02.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP ProLiant BL465c G7 (A19) Servers Version: 2014.www2.0 Release Notes Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06.02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL465c G7 System ROM .A19 Release Date: 02/02/2014 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 12/08/2012 Firmware Dependencies: None 43 Enhancements/New Features: None HP | Service Pack for ProLiant 2014.0 .com/bizsupport/TechSupport/Document.hp. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.0 Release Notes Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.HP ProLiant BL465c Gen8 (A26) Servers Version: 2014.06.06 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL465c Gen8 System ROM .06.HP Service Pack for ProLiant 2014. Known Issues: None Online ROM Flash Component for Linux .0 .A26 Release Date: 44 02/06/2014 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014.02. the server might experience a Non-System Disk Error or not boot the intended media.0 .HP Service Pack for ProLiant 2014.0 Release Notes 12/17/2012 Previous Revision: 11/02/2013 Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).06. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision. When this issue occurs. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: 45 Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active. This issue did not impact any other revisions of the System ROM. Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.06. HP | Service Pack for ProLiant 2014. 0 Release Notes Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06. the server might experience a Non-System Disk Error or not boot the intended media.HP ProLiant BL480c (I14) Server Version: 2011. Known Issues: None Enhancements Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.hp. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision.com/bizsupport/TechSupport/Document.05. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL480c G1 System ROM . When this issue occurs. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06. Online ROM Flash Component for Linux .HP Service Pack for ProLiant 2014. This issue did not impact any other revisions of the System ROM.I14 Release Date: 05/02/2011 Last Recommended or Critical Revision: 46 05/02/2011 Previous Revision: HP | Service Pack for ProLiant 2014.www2.0 . Once the system gets into this state. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.06.hp.hp. This is normally seen as HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.com/bizsupport/TechSupport/Document.0 Release Notes 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None 47 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 .www2. This is normally seen as the system hanging during system boot without anything displayed to video.06. 07. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL490 G6 System ROM .I21 Release Date: 07/02/2013 Last Recommended or Critical Revision: 48 07/02/2013 Previous Revision: HP | Service Pack for ProLiant 2014.0 Release Notes the system hanging during system boot without anything displayed to video. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.www2. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux .HP ProLiant BL490c G6 (I21) Servers Version: 2013.www2.com/bizsupport/TechSupport/Document. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.06.0 .02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Once the system gets into this state.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.HP Service Pack for ProLiant 2014. As a result of this issue. Intel Xeon Processor X5690. software may lose interrupts.0 49 . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. general protection faults. This issue does not impact any processors that are not listed above. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. receive spurious interrupts or cause a network disconnect. and have a guest OS utilizing 32-bit PAE Paging Mode.hp. While all processors supported by this server have this issue.jsp?locale=en_US&objectID=c0283837 HP | Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Addressed an issue with the Intel Xeon Processor X5675. have Intel Hyperthreading enabled. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.2. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. and IRQ Balancing enabled in the Operating System. such as Linux RedHat 6.06. this System ROM upgrade is considered a critical fix.www2. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.com/bizsupport/TechSupport/Document. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.HP Service Pack for ProLiant 2014. Due to the potential severity of the issue addressed in this revision of the System ROM.0 Release Notes 05/05/2011 Firmware Dependencies: None Enhancements/New Features: None. or machine check exceptions or other unpredictable system behavior. to be affected by this issue the server must be operating in a virtualized environment. HP ProLiant BL490c G7 (I28) Servers Version: 2013. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.HP Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. While all processors supported by this server have this issue. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.www2. and have a guest OS utilizing 32-bit PAE Paging Mode. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. Addressed an issue with the Intel Xeon Processor X5675.0 50 . This issue does not impact any processors that are not listed above.06. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. receive spurious interrupts or cause a network disconnect.06. Due to the potential severity of the issue addressed in this revision of the System ROM. this System ROM upgrade is considered a critical fix. Known Issues: None Online ROM Flash Component for Linux . general protection faults.hp.jsp?locale=en_US&objectID=c0283837 HP | Service Pack for ProLiant 2014. software may lose interrupts. to be affected by this issue the server must be operating in a virtualized environment.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. or machine check exceptions or other unpredictable system behavior. have Intel Hyperthreading enabled. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. As a result of this issue.com/bizsupport/TechSupport/Document.0 Release Notes 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. such as Linux RedHat 6.07. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and IRQ Balancing enabled in the Operating System. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Intel Xeon Processor X5690.2. general protection faults. this System ROM upgrade is considered a critical fix. As a HP | Service Pack for ProLiant 2014. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.HP Service Pack for ProLiant 2014.06. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. and IRQ Balancing enabled in the Operating System. or machine check exceptions or other unpredictable system behavior. This issue does not impact any processors that are not listed above. have Intel Hyperthreading enabled.2. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. and have a guest OS utilizing 32-bit PAE Paging Mode. Addressed an issue with the Intel Xeon Processor X5675. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.06.0 51 . Intel Xeon Processor X5690. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. While all processors supported by this server have this issue. to be affected by this issue the server must be operating in a virtualized environment. Due to the potential severity of the issue addressed in this revision of the System ROM. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. such as Linux RedHat 6.I28 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/03/2012 Firmware Dependencies: None Enhancements/New Features: None.0 Release Notes 5 Deliverable Name: HP ProLiant BL490c G7 System ROM . HP | Service Pack for ProLiant 2014.www2. have Intel Hyperthreading enabled. As a result of this issue. or machine check exceptions or other unpredictable system behavior. and IRQ Balancing enabled in the Operating System. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. This issue does not impact any processors that are not listed above.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. to be affected by this issue the server must be operating in a virtualized environment. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. While all processors supported by this server have this issue.06.06. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. receive spurious interrupts or cause a network disconnect. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Addressed an issue with the Intel Xeon Processor X5675. software may lose interrupts.hp. this System ROM upgrade is considered a critical fix. and have a guest OS utilizing 32-bit PAE Paging Mode.2.HP Service Pack for ProLiant 2014. software may lose interrupts. Intel Xeon Processor X5690.0 Release Notes result of this issue. general protection faults.0 52 . Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. receive spurious interrupts or cause a network disconnect.com/bizsupport/TechSupport/Document. such as Linux RedHat 6. jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL495c G5/G6 System ROM . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.A14 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 12/09/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.06.0 Release Notes Known Issues: None Online ROM Flash Component for Linux . Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: HP | Service Pack for ProLiant 2014.HP ProLiant BL495c G5/BL495c G6 (A14) Servers Version: 2011.05.0 53 .06.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. hp.www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.hp.06.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved an issue where the system may not be able to install an operating system to an iSCSI-based storage solution when using the local DVD drive. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.www2.jsp?locale=en_US&objectID=c0283837 5 Added latest product names for display in the ROM-Based Setup Utility (RBSU).www2.com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 54 .jsp?locale=en_US&objectID=c0283837 5 Added latest product names for display in the ROM-Based Setup Utility (RBSU). Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.hp.0 Release Notes http://h20000. HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. Problems Fixed: Resolved an issue where the system may not be able to install an operating system to an iSCSI-based storage solution when using the local DVD drive. HP ProLiant BL660c Gen8 (I32) Servers Version: 2014. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.0 Release Notes Online ROM Flash Component for Linux . With this revision of the System ROM. This revision of HP | Service Pack for ProLiant 2014.I32 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-4600 v2 series processors than was necessary.HP Service Pack for ProLiant 2014. This change does not impact servers configured with Intel Xeon E5-4600 series processors.06. the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations.0 55 . Improved the power allocation logic for servers configured with Intel Xeon E5-4600 v2 series processors to more accurately determine the server's maximum power usage.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL660c Gen8 System ROM .x on Intel Xeon E5-4600 series v2 processors.06.02. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.06. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.0 56 . This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting). This issue was originally seen with servers configured with Microsoft Windows Server 2012. This issue HP | Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This issue does not impact servers configured with Intel Xeon E5-4600 series processors.HP Service Pack for ProLiant 2014. Instead. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors. but might impact other operating systems. When this issue occurs. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.0 Release Notes the System ROM contains an updated version of Intel's microcode that addresses this issue.x on Intel Xeon E5-4600 series v2 processors.06. the server might experience a Non-System Disk Error or not boot the intended media. the NIC will not PXE boot or be identified or used by the operating system. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). When this issue occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When the issue occurs. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). This change does not impact servers configured with Intel Xeon E5-4600 series processors. but might impact other operating systems. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the server might experience a Non-System Disk Error or not boot the intended media. When this issue occurs. the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. Instead.06. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.HP Service Pack for ProLiant 2014. This issue was originally seen with servers configured with Microsoft Windows Server 2012. This issue does not impact servers configured with Intel Xeon E5-4600 series processors. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs.06. When this issue occurs. With this revision of the System ROM. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Improved the power allocation logic for servers configured with Intel Xeon E5-4600 v2 series processors to more accurately determine the server's maximum power usage. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting).02 (Critical) 57 Important Note! Important Notes: HP | Service Pack for ProLiant 2014. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-4600 v2 series processors than was necessary.HP ProLiant BL680c G5 (I17) Servers Version: 2011. Online ROM Flash Component for Linux . the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).05. the NIC will not PXE boot or be identified or used by the operating system.0 .0 Release Notes does NOT affect servers configured with the Intel Xeon E5-4600 series processors. com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 . Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL680c G5 System ROM .com/bizsupport/TechSupport/Document.www2.www2.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved an issue where the system may hang when trying to apply custom settings using the ROM Based Setup Utility (RBSU) User Defined Defaults Option.0 Release Notes As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.I17 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.06. Known Issues: 58 None Fixes HP | Service Pack for ProLiant 2014. HP ProLiant BL680c G7/BL620c G7 (I25) Servers Version: 2013. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06.0 Release Notes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux .06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved an issue where the system may hang when trying to apply custom settings using the ROM Based Setup Utility (RBSU) User Defined Defaults Option.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.01 (Critical) Important Note! Important Notes: None 59 Deliverable Name: HP ProLiant BL620c/BL680c G7 System ROM .hp.www2.HP Service Pack for ProLiant 2014.0 .I25 HP | Service Pack for ProLiant 2014.07. 0 . have Intel Hyperthreading enabled. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.06.HP Service Pack for ProLiant 2014. and have a guest OS utilizing 32-bit PAE Paging Mode.0 Release Notes Release Date: 07/01/2013 Last Recommended or Critical Revision: 07/01/2013 Previous Revision: 04/01/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. this System ROM upgrade is considered a critical fix. to be affected by this issue the server must be operating in a virtualized environment. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. general protection faults. or machine check exceptions or other unpredictable system behavior. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Known Issues: None Fixes Important Notes: None Firmware Dependencies: 60 None Problems Fixed: HP | Service Pack for ProLiant 2014. While all processors supported by this server have this issue.06. or machine check exceptions or other unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. have Intel Hyperthreading enabled.HP Service Pack for ProLiant 2014. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. general protection faults. Known Issues: None Online ROM Flash Component for Linux . While all processors supported by this server have this issue. Due to the potential severity of the issue addressed in this revision of the System ROM.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. this System ROM upgrade is considered a critical fix.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL685c G1/G5 System ROM .com/bizsupport/TechSupport/Document.05.A08 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 61 12/14/2009 HP | Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.HP ProLiant BL685c G1/BL685c G5 (A08) Servers Version: 2011.06.06. to be affected by this issue the server must be operating in a virtualized environment.0 . and have a guest OS utilizing 32-bit PAE Paging Mode.0 Release Notes Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.hp.www2. jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Added latest product names for display in the ROM-Based Setup Utility (RBSU).www2.www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Known Issues: 62 None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and HP | Service Pack for ProLiant 2014.0 Release Notes Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Added latest product names for display in the ROM-Based Setup Utility (RBSU).com/bizsupport/TechSupport/Document.06.HP Service Pack for ProLiant 2014.0 .06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.hp. www2.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 .A17 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 12/09/2009 Firmware Dependencies: None 63 Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.05.hp. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 Release Notes decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL685c G6 System ROM . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade HP | Service Pack for ProLiant 2014.06.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.hp.com/bizsupport/TechSupport/Document.www2.HP ProLiant BL685c G6 (A17) Servers Version: 2011.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the HP | Service Pack for ProLiant 2014.0 64 .hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Added latest product names for display in the ROM-Based Setup Utility (RBSU).06. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved an issue where the system may not be able to install an operating system to an iSCSI-based storage solution when using the local DVD drive.0 Release Notes process requires modifications to both the System ROM and the flash update utility. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Problems Fixed: Resolved an issue where the system may not be able to install an operating system to an iSCSI-based storage solution when using the local DVD drive. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.www2.www2.HP Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This issue did not impact any other revisions of the System ROM.0 Release Notes following link: http://h20000. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. Online ROM Flash Component for Linux .www2.02. HP | Service Pack for ProLiant 2014.01 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL685c G7 System ROM Release Date: 02/01/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 06/04/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.06.hp.com/bizsupport/TechSupport/Document.HP ProLiant BL685c G7 (A20) Servers Version: 2014.06.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Added latest product names for display in the ROM-Based Setup Utility (RBSU).0 65 . J03 Release Date: 02/10/2014 66 Last Recommended or Critical Revision: 12/20/2013 HP | Service Pack for ProLiant 2014.02. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.06.06.HP ProLiant DL160 Gen8 (J03) Servers Version: 2014. Known Issues: None Online ROM Flash Component for Linux . This issue did not impact any other revisions of the System ROM.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL160 Gen8 System ROM .0 Release Notes Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.HP Service Pack for ProLiant 2014.0 . x on Intel Xeon E5-2600 series v2 processors. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).06. When the issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.0 Release Notes Previous Revision: 12/20/2013 Firmware Dependencies: None. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.0 . Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. the NIC will not PXE boot or be identified or used by the operating system. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.06. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Known Issues: None 67 Fixes HP | Service Pack for ProLiant 2014. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.HP Service Pack for ProLiant 2014. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the server might experience a Non-System Disk Error or not boot the intended media. When this issue occurs. Instead. When this issue occurs. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. HP Service Pack for ProLiant 2014. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. the NIC will not PXE boot or be identified or used by the operating system. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Instead. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).x on Intel Xeon E5-2600 series v2 processors. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.0 .06. When the issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. When this issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. 68 HP | Service Pack for ProLiant 2014. When this issue occurs. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 Release Notes Important Notes: None Firmware Dependencies: None. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.06. 02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Online ROM Flash Component for Linux .07. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.HP ProLiant DL320 G5/DL320s (W04) Servers Version: 2008.HP ProLiant DL320 G6/ML330 G6 (W07) Servers Version: 2013. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.www2.com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014.W07 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: 69 None Enhancements/New Features: HP | Service Pack for ProLiant 2014.06.10 (Optional) Enhancements Added support for Generation 2 (3. This revision of the System ROM is required for proper operation of the embedded SATA solution when a Generation 2 (3.0 Release Notes Online ROM Flash Component for Linux .jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant ML330 G6 and DL320 G6 System ROM .06.0 .0 Gb/s) SATA Hard Drives.0 Gb/s) SATA hard drive is installed in the server (DL320 G5 only). As a result of this issue. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 Release Notes None. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. Due to the potential severity of the issue addressed in this revision of the System ROM.hp. This issue does not impact any processors that are not listed above. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. general protection faults.www2. and have a guest OS utilizing 32-bit PAE Paging Mode. software may lose interrupts. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. While all processors supported by this server have this issue.com/bizsupport/TechSupport/Document.06.2. have Intel Hyperthreading enabled. Addressed an issue with the Intel Xeon Processor X5675. such as Linux RedHat 6.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: 70 None Problems Fixed: HP | Service Pack for ProLiant 2014. and IRQ Balancing enabled in the Operating System. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.06. Intel Xeon Processor X5690. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. or machine check exceptions or other unpredictable system behavior. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. receive spurious interrupts or cause a network disconnect.0 . to be affected by this issue the server must be operating in a virtualized environment. this System ROM upgrade is considered a critical fix. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. receive spurious interrupts or cause a network disconnect.06. and have a guest OS utilizing 32-bit PAE Paging Mode.11. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.2. Intel Xeon Processor X5690. As a result of this issue. such as Linux RedHat 6. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. Known Issues: None Online ROM Flash Component for Linux .0 Release Notes Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.HP Service Pack for ProLiant 2014.06.0 . This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. to be affected by this issue the server must be operating in a virtualized environment. have Intel Hyperthreading enabled. While all processors supported by this server have this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Due to the potential severity of the issue addressed in this revision of the System ROM.J05 Release Date: 71 11/09/2013 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014. This issue does not impact any processors that are not listed above. software may lose interrupts. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Addressed an issue with the Intel Xeon Processor X5675. or machine check exceptions or other unpredictable system behavior.09 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL320e Gen8 System ROM .HP ProLiant DL320e Gen8 (J05) Servers Version: 2013. this System ROM upgrade is considered a critical fix. general protection faults. and IRQ Balancing enabled in the Operating System. the Power-On Delay Option will function as if the No Delay option were chosen. 30.0 Release Notes 08/24/2013 Previous Revision: 08/24/2013 Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. In some cases.06. the system must be using Integrated Lights-Out (iLO) Firmware version 1.0 . Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: 72 Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. Previously.06.20 or later. 30. For these new selections to function.HP Service Pack for ProLiant 2014. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). This allows the System ROM to attempt to boot the next device in the boot order. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. If the system is configured to one of the new options without having iLO Firmware version 1. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). the system must be using Integrated Lights-Out (iLO) Firmware version HP | Service Pack for ProLiant 2014.20 or later. For these new selections to function. 03.06. Previously. Known Issues: None Online ROM Flash Component for Linux . Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).20 or later.20 or later.P80 Release Date: 03/28/2014 Last Recommended or Critical Revision: 03/07/2014 Previous Revision: 03/07/2014 Firmware Dependencies: 73 None Enhancements/New Features: HP | Service Pack for ProLiant 2014. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error.0 Release Notes 1. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives.0 . the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device.HP Service Pack for ProLiant 2014. the Power-On Delay Option will function as if the No Delay option were chosen.06.HP ProLiant DL320e Gen8 v2 (P80) Servers Version: 2014. If the system is configured to one of the new options without having iLO Firmware version 1. This allows the System ROM to attempt to boot the next device in the boot order.28 (B) (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL320e Gen8 v2 System ROM . In some cases. 06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06. Known Issues: None Online ROM Flash Component for Linux .05.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.www2. This problem only affects servers with the 03/07/2014 revision of the System ROM.0 Release Notes None Problems Fixed: Addressed an issue where servers using the 03/07/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where servers using the 03/07/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test.0 74 . This problem only affects servers with the 03/07/2014 revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.HP ProLiant DL360 G5 (P58) Servers Version: 2011. This issue has no known impact with TPM functionality under normal operating system environments. This issue has no known impact with TPM functionality under normal operating system environments. Once the system gets into this state.06.hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2. This is normally seen as the system hanging during system boot without anything displayed to video. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.HP Service Pack for ProLiant 2014. Known Issues: None 75 Fixes Important Notes: HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.0 .P58 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.0 Release Notes Deliverable Name: HP ProLiant DL360 G5 System ROM . the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06. Once the system gets into this state.hp.hp.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux . Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2.HP ProLiant DL360 G6 (P64) Servers Version: 2013.com/bizsupport/TechSupport/Document.06.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.www2.06.07. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.www2.0 76 . the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. This is normally seen as the system hanging during system boot without anything displayed to video.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 Release Notes As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. 06.06. this System ROM upgrade is considered a critical fix. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.P64 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 05/05/2011 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. or machine check exceptions or other unpredictable system behavior. software may lose interrupts. general protection faults. have Intel Hyperthreading enabled. to be affected by this issue the server must be operating in a virtualized environment. and IRQ Balancing enabled in the Operating System. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. While all processors supported by this server have this issue.0 77 . As a result of this issue. receive spurious interrupts or cause a network HP | Service Pack for ProLiant 2014. Addressed an issue with the Intel Xeon Processor X5675. This issue does not impact any processors that are not listed above. such as Linux RedHat 6.2.HP Service Pack for ProLiant 2014. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Intel Xeon Processor X5690. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. and have a guest OS utilizing 32-bit PAE Paging Mode. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.0 Release Notes Deliverable Name: HP ProLiant DL360 G6 System ROM . This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Due to the potential severity of the issue addressed in this revision of the System ROM. to be affected by this issue the server must be operating in a virtualized environment. Known Issues: HP | Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 78 . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. software may lose interrupts. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. this System ROM upgrade is considered a critical fix.com/bizsupport/TechSupport/Document. and IRQ Balancing enabled in the Operating System.hp. While all processors supported by this server have this issue. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.06. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Intel Xeon Processor X5690.06.HP Service Pack for ProLiant 2014. have Intel Hyperthreading enabled. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This issue does not impact any processors that are not listed above. Due to the potential severity of the issue addressed in this revision of the System ROM.0 Release Notes disconnect.www2. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. or machine check exceptions or other unpredictable system behavior.2. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. receive spurious interrupts or cause a network disconnect.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. such as Linux RedHat 6. Addressed an issue with the Intel Xeon Processor X5675. and have a guest OS utilizing 32-bit PAE Paging Mode. As a result of this issue. general protection faults. 0 79 . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.P68 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. general protection faults.HP ProLiant DL360 G7 (P68) Servers Version: 2013. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.www2. HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. to be affected by this issue the server must be operating in a virtualized environment. have Intel Hyperthreading enabled. or machine check exceptions or other unpredictable system behavior.hp.com/bizsupport/TechSupport/Document.06. While all processors supported by this server have this issue.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL360 G7 System ROM .06.07.0 Release Notes None Online ROM Flash Component for Linux . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. or machine check exceptions or other unpredictable system behavior. this System ROM upgrade is considered a critical fix. Intel Xeon Processor X5690.www2. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Addressed an issue with the Intel Xeon Processor X5675. to be affected by this issue the server must be operating in a virtualized environment.06. receive spurious interrupts or cause a network disconnect. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.0 Release Notes and have a guest OS utilizing 32-bit PAE Paging Mode. general protection faults. have Intel Hyperthreading enabled.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.hp.2. Due to the potential severity of the issue addressed in this revision of the System ROM. such as Linux RedHat 6. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. and IRQ Balancing enabled in the Operating System. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.com/bizsupport/TechSupport/Document. and have a guest OS utilizing 32-bit PAE Paging Mode. this System ROM HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.06. Due to the potential severity of the issue addressed in this revision of the System ROM. software may lose interrupts. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This issue does not impact any processors that are not listed above. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. While all processors supported by this server have this issue. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 80 . Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. As a result of this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.HP ProLiant DL360e Gen8/DL380e Gen8 (P73) Servers Version: 2014.06. Addressed an issue with the Intel Xeon Processor X5675.HP Service Pack for ProLiant 2014. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.02. Intel Xeon Processor X5690.0 Release Notes upgrade is considered a critical fix.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL360e/DL380e Gen8 System ROM .2. As a result of this issue. software may lose interrupts.0 .06. This issue does not impact any processors that are not listed above. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. and IRQ Balancing enabled in the Operating System. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. receive spurious interrupts or cause a network disconnect.P73 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 81 Firmware Dependencies: None HP | Service Pack for ProLiant 2014. such as Linux RedHat 6. Known Issues: None Online ROM Flash Component for Linux . When this issue occurs. When the issue occurs.HP Service Pack for ProLiant 2014. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2400 series v2 processors.0 Release Notes Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).06. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.0 . When this issue occurs. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Known Issues: None Fixes Important Notes: None 82 Firmware Dependencies: None HP | Service Pack for ProLiant 2014. Instead. the server might experience a Non-System Disk Error or not boot the intended media. the NIC will not PXE boot or be identified or used by the operating system. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors.06. Instead. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Online ROM Flash Component for Linux .x on Intel Xeon E5-2400 series v2 processors. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). the NIC will not PXE boot or be identified or used by the operating system.HP ProLiant DL360p Gen8/DL360p Gen8 SE (P71) Servers Version: 2014.06.0 Release Notes Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.HP Service Pack for ProLiant 2014. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.02.0 . When this issue occurs. When the issue occurs.06. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions.10 (Optional) Important Note! 83 Important Notes: None HP | Service Pack for ProLiant 2014. When this issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Instead. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot HP | Service Pack for ProLiant 2014.0 84 .06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.06.P71 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. When this issue occurs.0 Release Notes Deliverable Name: HP ProLiant DL360p Gen8/DL360p Gen8 SE System ROM . Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.HP Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.x on Intel Xeon E5-2600 series v2 processors. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.0 Release Notes devices in the order specified by the Standard Boot Order (IPL). This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. the server might experience a Non-System Disk Error or not boot the intended media. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).x on Intel Xeon E5-2600 series v2 processors. When the issue occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Instead. When this issue occurs. When this issue occurs.0 . Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the NIC will not PXE boot or be identified or used by the HP | Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. When the issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.06. 85 Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the NIC will not PXE boot or be identified or used by the operating system. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.HP Service Pack for ProLiant 2014. 0 .www2.06.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.05.hp.0 Release Notes operating system. Online ROM Flash Component for Linux .A10 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 07/17/2009 Firmware Dependencies: None 86 Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and HP | Service Pack for ProLiant 2014.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014.HP ProLiant DL365 G1/DL365 G5 (A10) Servers Version: 2011.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL365 G1/G5 System ROM . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014.0 Release Notes decrease the probability of unintended corruption of the flash part. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: HP | Service Pack for ProLiant 2014.hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).www2.0 87 .com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.com/bizsupport/TechSupport/Document.com/bizsupport/TechSupport/Document.hp.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.0 88 .jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux .www2.05.HP Service Pack for ProLiant 2014.www2.www2.06.P56 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL380 G5 System ROM .0 Release Notes http://h20000.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.HP ProLiant DL380 G5 (P56) Server Version: 2011. jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document. Once the system gets into this state.www2. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.HP Service Pack for ProLiant 2014. This is normally seen as the system hanging during system boot without anything displayed to video. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: HP | Service Pack for ProLiant 2014.06.0 Release Notes Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. Once the system gets into this state.0 89 . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This is normally seen as the system hanging during system boot without anything displayed to video. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.06. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. P62 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 05/05/2011 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.06.www2. to be affected by this issue the server must be operating in a virtualized environment.07.0 Release Notes http://h20000.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.www2. have Intel HP | Service Pack for ProLiant 2014.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document. or machine check exceptions or other unpredictable system behavior.06. While all processors supported by this server have this issue. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL380 G6 System ROM .com/bizsupport/TechSupport/Document.0 90 .HP ProLiant DL380 G6 (P62) Servers Version: 2013. general protection faults.hp. 0 Release Notes Hyperthreading enabled. and IRQ Balancing enabled in the Operating System. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Due to the potential severity of the issue addressed in this revision of the System ROM. HP | Service Pack for ProLiant 2014. and have a guest OS utilizing 32-bit PAE Paging Mode. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.HP Service Pack for ProLiant 2014. While all processors supported by this server have this issue. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.com/bizsupport/TechSupport/Document.06. general protection faults. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. and have a guest OS utilizing 32-bit PAE Paging Mode. have Intel Hyperthreading enabled. or machine check exceptions or other unpredictable system behavior. As a result of this issue. such as Linux RedHat 6. software may lose interrupts. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.www2. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. this System ROM upgrade is considered a critical fix. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. receive spurious interrupts or cause a network disconnect.hp. Addressed an issue with the Intel Xeon Processor X5675. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 91 .2. Intel Xeon Processor X5690. to be affected by this issue the server must be operating in a virtualized environment. This issue does not impact any processors that are not listed above. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.06. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This issue does not impact any processors that are not listed above.hp.com/bizsupport/TechSupport/Document.P67 Release Date: 07/02/2013 Last Recommended or Critical Revision: 92 07/02/2013 Previous Revision: HP | Service Pack for ProLiant 2014. and IRQ Balancing enabled in the Operating System.www2.HP ProLiant DL380 G7 (P67) Servers Version: 2013.07. receive spurious interrupts or cause a network disconnect. software may lose interrupts. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. such as Linux RedHat 6.06.0 Release Notes Due to the potential severity of the issue addressed in this revision of the System ROM.HP Service Pack for ProLiant 2014. Addressed an issue with the Intel Xeon Processor X5675. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL380 G7 System ROM . Known Issues: None Online ROM Flash Component for Linux . As a result of this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. this System ROM upgrade is considered a critical fix.0 .2. Intel Xeon Processor X5690. As a result of this issue.0 Release Notes 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. or machine check exceptions or other unpredictable system behavior. such as Linux RedHat 6. software may lose interrupts. general protection faults.hp. receive spurious interrupts or cause a network disconnect. and have a guest OS utilizing 32-bit PAE Paging Mode.www2. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. While all processors supported by this server have this issue. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.2. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. Due to the potential severity of the issue addressed in this revision of the System ROM. Intel Xeon Processor X5690. and IRQ Balancing enabled in the Operating System.0 93 .jsp?locale=en_US&objectID=c0283837 HP | Service Pack for ProLiant 2014. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.HP Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.com/bizsupport/TechSupport/Document. to be affected by this issue the server must be operating in a virtualized environment. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. this System ROM upgrade is considered a critical fix. Addressed an issue with the Intel Xeon Processor X5675. have Intel Hyperthreading enabled. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This issue does not impact any processors that are not listed above.06. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Known Issues: None Online ROM Flash Component for Linux . this System ROM upgrade is considered a critical fix. general protection faults. software may lose interrupts.0 Release Notes 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. and IRQ Balancing enabled in the Operating System. and have a guest OS utilizing 32-bit PAE Paging Mode.06.HP ProLiant DL380p Gen8 (P70) Servers Version: 2014.02.10 (Optional) Important Note! Important Notes: 94 None Deliverable Name: HP | Service Pack for ProLiant 2014. to be affected by this issue the server must be operating in a virtualized environment. Due to the potential severity of the issue addressed in this revision of the System ROM. As a result of this issue. have Intel Hyperthreading enabled. such as Linux RedHat 6. or machine check exceptions or other unpredictable system behavior. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. While all processors supported by this server have this issue. Addressed an issue with the Intel Xeon Processor X5675. Intel Xeon Processor X5690. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.HP Service Pack for ProLiant 2014.2. receive spurious interrupts or cause a network disconnect.0 .06. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This issue does not impact any processors that are not listed above. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. When this issue occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.0 Release Notes HP ProLiant DL380p Gen8 System ROM . When this issue occurs. the server might experience a Non-System Disk Error or not boot the intended media. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.x on Intel Xeon E5-2600 series v2 processors. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.06.0 95 . the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.HP Service Pack for ProLiant 2014.06. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being HP | Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.P70 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None. Instead. the NIC will not PXE boot or be identified or used by the operating system.0 96 . This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). When this issue occurs. This issue does not impact servers configured with Intel Xeon E5-2600 series processors.06.HP Service Pack for ProLiant 2014. the NIC will not PXE boot or be identified or used by the operating system. the server might experience a Non-System Disk Error or not boot the intended media.06. Instead. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. When the issue occurs. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.0 Release Notes detected by the platform. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. When this issue occurs. When the issue occurs. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.x on Intel Xeon E5-2600 series v2 processors. Known Issues: None HP | Service Pack for ProLiant 2014. com/bizsupport/TechSupport/Document. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 97 .06.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL385 G2/G5 System ROM . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.HP ProLiant DL385 G2/DL385 G5 (A09) Servers Version: 2011.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.05.0 Release Notes Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Online ROM Flash Component for Linux . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: HP | Service Pack for ProLiant 2014.A09 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 07/11/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06. hp. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.hp.com/bizsupport/TechSupport/Document. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.www2.www2.0 98 .www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).06.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 Release Notes http://h20000. 02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.05.www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.A22 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 02/09/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.com/bizsupport/TechSupport/Document.www2.hp.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.HP ProLiant DL385 G5p/DL385 G6 (A22) Servers Version: 2011.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL385 G5p/G6 System ROM .06.0 99 .HP Service Pack for ProLiant 2014. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.0 Release Notes Online ROM Flash Component for Linux . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. would not be reported correctly when a three slot PCI-E riser is installed in the platform. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 .hp.02.com/bizsupport/TechSupport/Document.0 Release Notes Problems Fixed: Resolved an issue where the in PCI Slot number. would not be reported correctly when a three slot PCI-E riser is installed in the platform.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved an issue where the in PCI Slot number. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. as reported under the operating system. as reported under the operating system.jsp?locale=en_US&objectID=c0283837 5 100 Online ROM Flash Component for Linux .com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.www2.02 (Optional) HP | Service Pack for ProLiant 2014.HP ProLiant DL385 G7 (A18) Servers Version: 2014.hp.06. 0 Release Notes Important Note! Important Notes: None Deliverable Name: HP ProLiant DL385 G7 System ROM .0 .HP Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: None 101 Firmware Dependencies: None HP | Service Pack for ProLiant 2014.06.A18 Release Date: 02/02/2014 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 12/08/2012 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.06. 02. Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order HP | Service Pack for ProLiant 2014.06. Known Issues: None Online ROM Flash Component for Linux .06 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL385p Gen8 System ROM .06.HP Service Pack for ProLiant 2014.A28 Release Date: 02/06/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 11/02/2013 Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).0 Release Notes Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.0 102 .HP ProLiant DL385p Gen8 (A28) Servers Version: 2014. This issue did not impact any other revisions of the System ROM. the server might experience a Non-System Disk Error or not boot the intended media. When this issue occurs. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.HP Service Pack for ProLiant 2014.06. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.0 . This issue did not impact any other revisions of the System ROM. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. Known Issues: None 103 Enhancements Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). When this issue occurs. the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.06. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active. HP | Service Pack for ProLiant 2014.0 Release Notes (IPL) with certain Network Adapters. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.P77 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.HP ProLiant DL560 Gen8 (P77) Servers Version: 2014. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors.HP Service Pack for ProLiant 2014. This issue does NOT impact any System ROM revisions other than the HP | Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. When this issue occurs.06. the server might experience a Non-System Disk Error or not boot the intended media.02.0 104 .06. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.0 Release Notes Online ROM Flash Component for Linux .10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL560 Gen8 System ROM .x on Intel Xeon E5-4600 series v2 processors. 06. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This issue does NOT impact any System ROM revisions other than the HP | Service Pack for ProLiant 2014. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting).HP Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Instead. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.x on Intel Xeon E5-4600 series v2 processors. When the issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This issue was originally seen with servers configured with Microsoft Windows Server 2012.0 105 . When this issue occurs. When this issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. but might impact other operating systems. This issue does not impact servers configured with Intel Xeon E5-4600 series processors. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. the NIC will not PXE boot or be identified or used by the operating system.0 Release Notes 11/14/2013 and 12/20/2013 revisions. the server might experience a Non-System Disk Error or not boot the intended media.06. Instead. Online ROM Flash Component for Linux .0 Release Notes 11/14/2013 and 12/20/2013 revisions. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-4600 series processors. When this issue occurs. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors.jsp?locale=en_US&objectID=c0283837 5 106 Deliverable Name: HP ProLiant DL580 G5 System ROM .06. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting). Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.P61 HP | Service Pack for ProLiant 2014. When the issue occurs. but might impact other operating systems.05.www2. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).HP Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06. This issue was originally seen with servers configured with Microsoft Windows Server 2012. the NIC will not PXE boot or be identified or used by the operating system.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.HP ProLiant DL580 G5 (P61) Servers Version: 2011.0 . Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). 06.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved an issue where the system may hang when trying to apply custom settings using the ROM Based Setup Utility (RBSU) User Defined Defaults Option. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.www2. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.hp.0 Release Notes Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.0 107 . 06.10.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. it is not necessary to update to ver.HP ProLiant DL580 G7 (P65) Servers Version: 2013.0 .P65 108 Release Date: 10/01/2013 HP | Service Pack for ProLiant 2014.01(B). The actual BIOS Firmware contained within ver. The 10/01/2013 System ROM revision addresses the performance issue.10. The performance issue was unique to the 07/01/2013 System ROM revision for the DL580 G7. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.com/bizsupport/TechSupport/Document.06. 2013. All HP ProLiant DL580 G7 servers should update to the 10/01/2013 System ROM instead. Deliverable Name: HP ProLiant DL580 G7 System ROM . It does not affect any other ProLiant servers or any other HP ProLiant DL580 G7 System ROM revisions.01.10.www2. If using BIOS Firmware ver 2013.10.0 Release Notes Firmware Dependencies: None Problems Fixed: Resolved an issue where the system may hang when trying to apply custom settings using the ROM Based Setup Utility (RBSU) User Defined Defaults Option.01. 2013. 2013.10.hp.01 (B) (Critical) Important Note! Important Notes: IMPORTANT: The 07/01/2013 System ROM has an issue that can result in reduced performance and it has been removed from the HP Support Site. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.01(B) did not change as compared to ver.HP Service Pack for ProLiant 2014. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. and have a guest OS utilizing 32-bit PAE Paging Mode. Known Issues: None Fixes Important Notes: IMPORTANT: The 07/01/2013 System ROM has an issue that can result in reduced performance and it has been removed from the HP Support Site. It HP | Service Pack for ProLiant 2014. The 10/01/2013 System ROM revision addresses the performance issue. This issue does NOT affect other revisions of the System ROM.0 Release Notes Last Recommended or Critical Revision: 10/01/2013 Previous Revision: 04/01/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed an issue with the 07/01/2013 revision of the System ROM that could result in decreased performance. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. The performance issue was unique to the 07/01/2013 System ROM revision for the DL580 G7. While all processors supported by this server have this issue. this System ROM upgrade is considered a critical fix.06. Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Due to an issue with the thermal solution included in that revision of the System ROM. have Intel Hyperthreading enabled. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Addressed an issue where the Intelligent Platform Management Interface (IPMI) based power reporting would not function properly and report an incorrect wattage from the installed Power Supplies. Due to the potential severity of the issue addressed in this revision of the System ROM. to be affected by this issue the server must be operating in a virtualized environment. the processor may be "throttled" to a reduced frequency when not necessary. or machine check exceptions or other unpredictable system behavior. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 109 .HP Service Pack for ProLiant 2014. All HP ProLiant DL580 G7 servers should update to the 10/01/2013 System ROM instead.06. general protection faults. Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.01(B). 2013.02_04-01-2014 (Optional) Important Note! Important Notes: None 110 Deliverable Name: HP ProLiant DL580 Gen8 System ROM . this System ROM upgrade is considered a critical fix.P79 HP | Service Pack for ProLiant 2014.HP ProLiant DL580 Gen8 (P79) Servers Version: 1. the processor may be "throttled" to a reduced frequency when not necessary.HP Service Pack for ProLiant 2014. to be affected by this issue the server must be operating in a virtualized environment. Addressed an issue where the Intelligent Platform Management Interface (IPMI) based power reporting would not function properly and report an incorrect wattage from the installed Power Supplies. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. The actual BIOS Firmware contained within ver. Due to the potential severity of the issue addressed in this revision of the System ROM. Firmware Dependencies: None Problems Fixed: Addressed an issue with the 07/01/2013 revision of the System ROM that could result in decreased performance.06.10.06. or machine check exceptions or other unpredictable system behavior. it is not necessary to update to ver. Due to an issue with the thermal solution included in that revision of the System ROM.10. This issue does NOT affect other revisions of the System ROM.10. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Known Issues: None Online ROM Flash Component for Linux . If using BIOS Firmware ver 2013. general protection faults. 2013. 2013.01.01(B) did not change as compared to ver.10.0 .01. and have a guest OS utilizing 32-bit PAE Paging Mode. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 Release Notes does not affect any other ProLiant servers or any other HP ProLiant DL580 G7 System ROM revisions. While all processors supported by this server have this issue. have Intel Hyperthreading enabled. 01_03-19-2014 Previous Revision: 1.06.0 Release Notes Release Version: 1. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014.06.0 111 . This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed. HP | Service Pack for ProLiant 2014.x or Microsoft Hyper-V on Intel Xeon E7-4800 series v2 processors.01_03-19-2014 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on VMware ESX 5.02_04-01-2014 Last Recommended or Critical Revision: 1. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.x or Microsoft Hyper-V on Intel Xeon E7-4800 series v2 processors. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on VMware ESX 5. jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL585 G2/G5/G6 System ROM .hp.0 112 .A07 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 04/30/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 Release Notes Known Issues: None Online ROM Flash Component for Linux .www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.05.HP ProLiant DL585 G2/DL585 G5/DL585 G6 (A07) Servers Version: 2011. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06. A customer can downgrade the System ROM by creating a new flash HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.www2.hp. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2.com/bizsupport/TechSupport/Document.0 Release Notes component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 113 .jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document. The instability could result in unexpected resets with Uncorrectable Chipset errors reported in the Integrated Management Log (IML).02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL585 G7 System ROM Release Date: 02/02/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 06/04/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved an issue where the HP NC375i Integrated Quad Port Gigabit Adapter could cause system instability. this issue might cause some versions of Microsoft Windows to boot into Recovery Mode. This issue did not impact any other revisions of the System ROM. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.06.02. In addition. 114 Known Issues: None HP | Service Pack for ProLiant 2014.06.HP Service Pack for ProLiant 2014.0 Release Notes Online ROM Flash Component for Linux .0 .HP ProLiant DL585 G7 (A16) Servers Version: 2014. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. In some cases Operating Systems might report errors. com/bizsupport/TechSupport/Document. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.hp. In some cases Operating Systems might report errors.05. In addition.06.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This issue did not impact any other revisions of the System ROM.0 Release Notes Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved an issue where the HP NC375i Integrated Quad Port Gigabit Adapter could cause system instability.A15 115 Release Date: HP | Service Pack for ProLiant 2014. this issue might cause some versions of Microsoft Windows to boot into Recovery Mode.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL785 G5/G6 System ROM . Known Issues: None Online ROM Flash Component for Linux . The instability could result in unexpected resets with Uncorrectable Chipset errors reported in the Integrated Management Log (IML). the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2.06. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 .HP Service Pack for ProLiant 2014.HP ProLiant DL785 G5/DL785 G6 (A15) Servers Version: 2011. hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06.com/bizsupport/TechSupport/Document.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved an issue where the System ROM would not populate the System Enclosure or Chassis (type 3) SMBIOS record with text entered by the user in the Server Asset Tag Text Line in the ROM-Based Setup Utility (RBSU).www2.www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.0 Release Notes 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 12/04/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014. Resolved an issue where the user may be unable to select and use the '57600' and '115200' options in the "BIOS Serial Console Baud Rate" menu in the ROM-Based Setup Utility (RBSU). Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 116 . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.0 .com/bizsupport/TechSupport/Document.12.HP Service Pack for ProLiant 2014.0 Release Notes Firmware Dependencies: None Problems Fixed: Resolved an issue where the System ROM would not populate the System Enclosure or Chassis (type 3) SMBIOS record with text entered by the user in the Server Asset Tag Text Line in the ROM-Based Setup Utility (RBSU). the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2. Resolved an issue where the user may be unable to select and use the '57600' and '115200' options in the "BIOS Serial Console Baud Rate" menu in the ROM-Based Setup Utility (RBSU).31 (Recommended) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL980 G7 System ROM .HP ProLiant DL980 G7 (P66) Servers Version: 2013. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux . Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06.P66 Release Date: 12/31/2013 117 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014.06. Addressed an extremely rare issue where the system might stop responding and reboot unexpectedly during an Operating System boot or run time. TPM does not work in an HP | Service Pack for ProLiant 2014. and reports a lot of Uncorrectable Machine Check Event in the IML (Integrated Management Log).HP Service Pack for ProLiant 2014. Status 0xF6000000'00000972.0 .0 via PXE.06. Processor 2. this issue would typically be seen on every warm reboot.0.06. APIC ID 0x00000040. Updated the embedded PXE Firmware to gPXE Version 4. Availability and Serviceability). Bank 0x0000000E. This error would typically be seen with a lot of following IML information: Uncorrectable Machine Check Exception (Board 0.0 Release Notes 12/31/2013 Previous Revision: 07/29/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the DDDC (Double Device Data Correction) aware POST (Power On Self Test) feature.582. This firmware addresses an issue where the system might stop responding during the deployment of VMware Vcenter 5. TPM does not work in an Operation System after a system boot. Address 0x00000023'7B6E25C0. which will improve the system memory's RAS (Reliability. Problems Fixed: Addressed an issue where the system may delay to POST or fail to boot when the TPM (Trusted Platform Module) is enabled. Customers who experience this event need to update to this version of the System ROM before contacting HP Support. this issue would typically be seen on every warm reboot. Misc 0x00000000'00000000). Known Issues: None Fixes Important Notes: None Firmware Dependencies: None 118 Problems Fixed: Addressed an issue where the system may delay to POST or fail to boot when the TPM (Trusted Platform Module) is enabled. HP ProLiant MicroServer Gen8 (J06) Servers Version: 2013. Misc 0x00000000'00000000).J06 Release Date: 11/09/2013 Last Recommended or Critical Revision: 08/24/2013 Previous Revision: 119 08/24/2013 HP | Service Pack for ProLiant 2014.0.09 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant MicroServer Gen8 System ROM . Online ROM Flash Component for Linux . Customers who experience this event need to update to this version of the System ROM before contacting HP Support.HP Service Pack for ProLiant 2014. Status 0xF6000000'00000972.06.06. Updated the embedded PXE Firmware to gPXE Version 4.0 via PXE. Processor 2.582. and reports a lot of Uncorrectable Machine Check Event in the IML (Integrated Management Log).0 . Known Issues: None Enhancements Added support for the DDDC (Double Device Data Correction) aware POST (Power On Self Test) feature. which will improve the system memory's RAS (Reliability. Address 0x00000023'7B6E25C0. Bank 0x0000000E. APIC ID 0x00000040. This error would typically be seen with a lot of following IML information: Uncorrectable Machine Check Exception (Board 0. This firmware addresses an issue where the system might stop responding during the deployment of VMware Vcenter 5. Availability and Serviceability).11.0 Release Notes Operation System after a system boot. Addressed an extremely rare issue where the system might stop responding and reboot unexpectedly during an Operating System boot or run time. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. In some cases. If the system is configured to one of the new options without having iLO Firmware version 1.0 Release Notes Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. the Power-On Delay Option will function as if the No Delay option were chosen. This allows the System ROM to attempt to boot the next device in the boot order. Previously.20 or later. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). the Power-On Delay Option will function as if the No Delay option were chosen. For these new selections to function. the system must be using Integrated Lights-Out (iLO) Firmware version 1. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error.20 or later. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). the system must be using Integrated Lights-Out (iLO) Firmware version 1. Previously.0 120 .06. In some cases.20 or later. For these new selections to function. 30.HP Service Pack for ProLiant 2014. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). If the system is configured to one of the new options without having iLO Firmware version 1. the System ROM will now be able to detect HP | Service Pack for ProLiant 2014.20 or later. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives.06. 30. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. J01 Release Date: 07/01/2013 Last Recommended or Critical Revision: 07/01/2013 Previous Revision: 12/04/2012 Firmware Dependencies: None Enhancements/New Features: None 121 Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to HP | Service Pack for ProLiant 2014. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).01 (Critical) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML110 G7 and DL120 G7 System ROM .0 .06.HP ProLiant ML110 G7/DL120 G7 (J01) Servers Version: 2013. This allows the System ROM to attempt to boot the next device in the boot order. Known Issues: None Online ROM Flash Component for Linux .HP Service Pack for ProLiant 2014.0 Release Notes the invalid boot record and skip attempting to boot the device.07.06. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. or machine check exceptions or other unpredictable system behavior.HP Service Pack for ProLiant 2014.0 Release Notes experience unexpected page faults. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and have a guest OS utilizing 32-bit PAE Paging Mode. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.HP ProLiant ML310 G5/DL320 G5p (W05) Servers Version: 2010.25 (Critical) 122 Important Note! HP | Service Pack for ProLiant 2014. have Intel Hyperthreading enabled. general protection faults. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.0 . this System ROM upgrade is considered a critical fix. general protection faults. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Due to the potential severity of the issue addressed in this revision of the System ROM. this System ROM upgrade is considered a critical fix. to be affected by this issue the server must be operating in a virtualized environment. or machine check exceptions or other unpredictable system behavior. While all processors supported by this server have this issue. have Intel Hyperthreading enabled. to be affected by this issue the server must be operating in a virtualized environment. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. While all processors supported by this server have this issue. Known Issues: None Online ROM Flash Component for Linux . Due to the potential severity of the issue addressed in this revision of the System ROM.06. and have a guest OS utilizing 32-bit PAE Paging Mode.10. This issue affects platforms utilizing Intel Xeon 3100-series.06. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D.0 Release Notes Important Notes: None Deliverable Name: HP ProLiant DL320 G5p/ML310 G5 System ROM . HP strongly recommends immediate update to firmware revisions with required critical fixes. 0x00000000)".W05 Release Date: 10/25/2010 Last Recommended or Critical Revision: 10/25/2010 Previous Revision: 07/11/2009 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error.HP Service Pack for ProLiant 2014. 123 Known Issues: None HP | Service Pack for ProLiant 2014.0 . blue screen. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue.06. Due to the potential severity of the issue addressed in this revision of the System ROM. and Intel Core 2 Duo Desktop E4000-series processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. or other unpredictable system behavior. Intel Xeon 3200-series. Intel Pentium Dual-Core Desktop E2000-series. Intel Xeon 3300-series. kernel panic. this System ROM upgrade is considered a critical fix. Intel Xeon 3200-series. Due to the potential severity of the issue addressed in this revision of the System ROM. Intel Pentium Dual-Core Desktop E2000-series. Known Issues: None Online ROM Flash Component for Linux . Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D.HP Service Pack for ProLiant 2014.0 Release Notes Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. and Intel Core 2 Duo Desktop E4000-series processors.W08 124 Release Date: 10/25/2010 HP | Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using affected processors.10. or other unpredictable system behavior. HP strongly recommends immediate update to firmware revisions with required critical fixes.25 (Critical) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML310 G5p System ROM .06. kernel panic. Intel Xeon 3300-series. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue.0 . blue screen. This issue affects platforms utilizing Intel Xeon 3100-series. this System ROM upgrade is considered a critical fix.06. 0x00000000)".HP ProLiant ML310 G5p (W08) Servers Version: 2010. or other unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. HP strongly recommends immediate update to firmware revisions with required critical fixes.0 .06. blue screen. and Intel Core 2 Quad Q9000-series processors. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None 125 Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit HP | Service Pack for ProLiant 2014. Intel Xeon 3300-series. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. this System ROM upgrade is considered a critical fix. 0x00000000)".0 Release Notes Last Recommended or Critical Revision: 10/25/2010 Previous Revision: 07/12/2009 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. Intel Pentium Dual-Core Desktop E2000-series. kernel panic.HP Service Pack for ProLiant 2014. Intel Core 2 Duo E8000series.06. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. This issue affects platforms utilizing Intel Xeon 3100-series. Intel Core 2 Duo Desktop E6000-series. This issue affects platforms utilizing Intel Xeon 3100-series. this System ROM upgrade is considered a critical fix.HP ProLiant ML310e Gen8 (J04) Servers Version: 2013.06. blue screen. Due to the potential severity of the issue addressed in this revision of the System ROM.06. HP strongly recommends immediate update to firmware revisions with required critical fixes. and Intel Core 2 Quad Q9000-series processors.09 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML310e Gen8 System ROM . Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. Intel Core 2 Duo E8000series. kernel panic. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue. or other unpredictable system behavior. 0x00000000)". Intel Xeon 3300-series.0 Release Notes mode could result in an application-level error. Intel Core 2 Duo Desktop E6000-series.11. Known Issues: None Online ROM Flash Component for Linux . This issue is not unique to HP ProLiant servers and could impact any system using affected processors.J04 Release Date: 11/09/2013 Last Recommended or Critical Revision: 08/24/2013 Previous Revision: 08/24/2013 Firmware Dependencies: 126 None HP | Service Pack for ProLiant 2014.0 .HP Service Pack for ProLiant 2014. Intel Pentium Dual-Core Desktop E2000-series. 20 or later. This allows the System ROM to attempt to boot the next device in the boot order. 30. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives.06. the system must be using Integrated Lights-Out (iLO) Firmware version 1. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device.06. the Power-On Delay Option will function as if the No Delay option were chosen.0 127 . In some cases. In some cases. Previously. If the system is configured to one of the new options without having iLO Firmware version 1.20 or later. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device.HP Service Pack for ProLiant 2014. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. For these new selections to function. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. the Power-On Delay Option will function as if the No Delay option were chosen. the system must be using Integrated Lights-Out (iLO) Firmware version 1. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). If the system is configured to one of the new options without having iLO Firmware version 1. 30. Previously. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). HP | Service Pack for ProLiant 2014. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. This allows the System ROM to attempt to boot the next device in the boot order.20 or later. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay).0 Release Notes Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. For these new selections to function.20 or later. This problem only affects servers with the 03/08/2014 revision of the System ROM.0 Release Notes Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). Known Issues: None Online ROM Flash Component for Linux .06. HP | Service Pack for ProLiant 2014.0 128 .06.28 (B) (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML310e Gen8 v2 System ROM .HP ProLiant ML310e Gen8 v2 (P78) Servers Version: 2014.HP Service Pack for ProLiant 2014.P78 Release Date: 03/28/2014 Last Recommended or Critical Revision: 03/08/2014 Previous Revision: 03/08/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed an issue where servers using the 03/08/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test.03. This issue has no known impact with TPM functionality under normal operating system environments. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.D21 129 Release Date: HP | Service Pack for ProLiant 2014.06. This issue has no known impact with TPM functionality under normal operating system environments.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.05.hp.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant ML350 G5 System ROM .www2. Known Issues: None Online ROM Flash Component for Linux .com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014. This problem only affects servers with the 03/08/2014 revision of the System ROM.HP ProLiant ML350 G5 (D21) Servers Version: 2011. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 .0 Release Notes Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where servers using the 03/08/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.HP Service Pack for ProLiant 2014. This is normally seen as the system hanging during system boot without anything displayed to video. Once the system gets into this state. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 Release Notes 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.www2. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06.06.com/bizsupport/TechSupport/Document.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 130 . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.hp.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. www2.0 Release Notes Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: 131 HP ProLiant ML350 G6 System ROM . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.D22 HP | Service Pack for ProLiant 2014.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014.07. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.0 . Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux .www2.HP ProLiant ML350 G6 (D22) Servers Version: 2013.06. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This is normally seen as the system hanging during system boot without anything displayed to video.06.hp.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Once the system gets into this state. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.06. As a result of this issue.0 .0 Release Notes Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. or machine check exceptions or other unpredictable system behavior. This issue does not impact any processors that are not listed above. general protection faults. 132 Known Issues: None HP | Service Pack for ProLiant 2014. While all processors supported by this server have this issue. and IRQ Balancing enabled in the Operating System. receive spurious interrupts or cause a network disconnect. to be affected by this issue the server must be operating in a virtualized environment. Intel Xeon Processor X5690. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. this System ROM upgrade is considered a critical fix. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Addressed an issue with the Intel Xeon Processor X5675. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. have Intel Hyperthreading enabled. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. software may lose interrupts. Due to the potential severity of the issue addressed in this revision of the System ROM.06. and have a guest OS utilizing 32-bit PAE Paging Mode.2. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.HP Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. such as Linux RedHat 6. such as Linux RedHat 6.06. While all processors supported by this server have this issue. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. As a result of this issue. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. general protection faults.com/bizsupport/TechSupport/Document. Known Issues: None 133 HP | Service Pack for ProLiant 2014.0 Release Notes Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This issue does not impact any processors that are not listed above. to be affected by this issue the server must be operating in a virtualized environment. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Addressed an issue with the Intel Xeon Processor X5675. Intel Xeon Processor X5690.hp. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. or machine check exceptions or other unpredictable system behavior. and IRQ Balancing enabled in the Operating System.2. have Intel Hyperthreading enabled.0 . receive spurious interrupts or cause a network disconnect.06. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014. and have a guest OS utilizing 32-bit PAE Paging Mode. software may lose interrupts. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Due to the potential severity of the issue addressed in this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. this System ROM upgrade is considered a critical fix.www2. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/22/2013 revisions. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06.HP Service Pack for ProLiant 2014. When this issue occurs. HP | Service Pack for ProLiant 2014.0 134 .02. the server might experience a Non-System Disk Error or not boot the intended media.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML350e Gen8/ML350e Gen8 v2 System ROM .J02 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/22/2013 Previous Revision: 12/22/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).x on Intel Xeon E5-2400 series v2 processors.0 Release Notes Online ROM Flash Component for Linux . This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where servers using the 11/12/2013 or 12/22/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors.06.HP ProLiant ML350e Gen8/ML350e Gen8 v2 (J02) Servers Version: 2014. 06. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/22/2013 revisions.HP Service Pack for ProLiant 2014. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. the NIC will not PXE boot or be identified or used by the operating system. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. When this issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.x on Intel Xeon E5-2400 series v2 processors. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Instead. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. HP | Service Pack for ProLiant 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. When this issue occurs.0 135 .0 Release Notes Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the server might experience a Non-System Disk Error or not boot the intended media. When this issue occurs. When the issue occurs.06. Addressed an issue where servers using the 11/12/2013 or 12/22/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. 0 . When the issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Instead. HP | Service Pack for ProLiant 2014. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.HP ProLiant ML350p Gen8 (P72) Servers Version: 2014.0 Release Notes Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.02.06.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML350p Gen8 System ROM . Online ROM Flash Component for Linux .06.HP Service Pack for ProLiant 2014. the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).P72 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: 136 None. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.06. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.06. Known Issues: None Fixes Important Notes: None 137 Firmware Dependencies: None.0 Release Notes Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 . the NIC will not PXE boot or be identified or used by the operating system.HP Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. When the issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs. HP | Service Pack for ProLiant 2014. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.x on Intel Xeon E5-2600 series v2 processors. When this issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Instead. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in HP | Service Pack for ProLiant 2014. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When the issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.0 Release Notes Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.HP ProLiant ML370 G5 (P57) Server Version: 2011.02 (Critical) Important Note! Important Notes: 138 As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Online ROM Flash Component for Linux . This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. When this issue occurs.06. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). the server might experience a Non-System Disk Error or not boot the intended media. Instead. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.05.x on Intel Xeon E5-2600 series v2 processors.06. the NIC will not PXE boot or be identified or used by the operating system.0 . When this issue occurs. This issue does not impact servers configured with Intel Xeon E5-2600 series processors.HP Service Pack for ProLiant 2014. jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant ML370 G5 System ROM .com/bizsupport/TechSupport/Document.www2.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This is normally seen as the system hanging during system boot without anything displayed to video. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.www2.P57 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.hp. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.06.com/bizsupport/TechSupport/Document.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.HP Service Pack for ProLiant 2014. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Once the system gets into this state.0 Release Notes Advisory C02838375 available at the following link: http://h20000. Known Issues: 139 None Fixes HP | Service Pack for ProLiant 2014.0 . 02 (Critical) Important Note! 140 Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.com/bizsupport/TechSupport/Document. Once the system gets into this state.06. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the System ROM revision cannot be downgraded with the flash components available on the HP HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.0 . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.07. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.06. This is normally seen as the system hanging during system boot without anything displayed to video. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014.www2.0 Release Notes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Linux .HP ProLiant ML370 G6/DL370 G6 (P63) Servers Version: 2013. HP | Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.HP Service Pack for ProLiant 2014. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. have Intel Hyperthreading enabled.com/bizsupport/TechSupport/Document. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. to be affected by this issue the server must be operating in a virtualized environment. Addressed an issue with the Intel Xeon Processor X5675. and have a guest OS utilizing 32-bit PAE Paging Mode.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.www2.hp. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant ML370 G6/DL370 G6 System ROM . and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. general protection faults. this System ROM upgrade is considered a critical fix. or machine check exceptions or other unpredictable system behavior. While all processors supported by this server have this issue.0 141 . Intel Xeon Processor X5690.0 Release Notes Support site after updating to this revision of the System ROM.06.P63 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Due to the potential severity of the issue addressed in this revision of the System ROM. 0 Release Notes This issue does not impact any processors that are not listed above. As a HP | Service Pack for ProLiant 2014. software may lose interrupts. As a result of this issue. While all processors supported by this server have this issue. this System ROM upgrade is considered a critical fix. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.0 142 . to be affected by this issue the server must be operating in a virtualized environment. Due to the potential severity of the issue addressed in this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.www2. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.06. Intel Xeon Processor X5690. This issue does not impact any processors that are not listed above. such as Linux RedHat 6. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Addressed an issue with the Intel Xeon Processor X5675. and IRQ Balancing enabled in the Operating System.com/bizsupport/TechSupport/Document. receive spurious interrupts or cause a network disconnect. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. have Intel Hyperthreading enabled. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. general protection faults. or machine check exceptions or other unpredictable system behavior.hp.2. such as Linux RedHat 6.HP Service Pack for ProLiant 2014.2. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. and IRQ Balancing enabled in the Operating System. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and have a guest OS utilizing 32-bit PAE Paging Mode. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).06.0 143 . This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. receive spurious interrupts or cause a network disconnect.HP ProLiant SL210t Gen8 (P83) Servers Version: 2014. Known Issues: None Online ROM Flash Component for Linux .x on Intel Xeon E5-2600 series v2 processors. software may lose interrupts.02. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 Release Notes result of this issue. This issue HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL210t Gen8 System ROM .P83 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.x on Intel Xeon E5-2600 series v2 processors. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. When this issue occurs. When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. When this issue occurs. This issue does NOT impact any System ROM revisions other than the HP | Service Pack for ProLiant 2014. the NIC will not PXE boot or be identified or used by the operating system. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Instead.06. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. 144 Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.0 .0 Release Notes does NOT affect servers configured with the Intel Xeon E5-2600 series processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the server might experience a Non-System Disk Error or not boot the intended media. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.HP Service Pack for ProLiant 2014.06. When the issue occurs. Instead.0 . Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.HP ProLiant SL230s/SL250s/SL270s Gen8/SL270s Gen8 SE (P75) Servers Version: 2014. the NIC will not PXE boot or be identified or used by the operating system.06. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL230s/250s/270s Gen8/270s Gen8 SE System ROM . Online ROM Flash Component for Linux . This issue does not impact servers configured with Intel Xeon E5-2600 series processors.06. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).02.P75 Release Date: 02/10/2014 Last Recommended or Critical Revision: 145 12/20/2013 Previous Revision: HP | Service Pack for ProLiant 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.HP Service Pack for ProLiant 2014.0 Release Notes 11/14/2013 and 12/20/2013 revisions. When this issue occurs. HP Service Pack for ProLiant 2014.06.0 Release Notes 12/20/2013 Firmware Dependencies: None. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Fixes 146 Important Notes: None HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Firmware Dependencies: None. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Online ROM Flash Component for Linux - HP ProLiant SL335s G7 (A24) Servers Version: 2012.12.08 (Recommended) 147 Important Note! HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Important Notes: None Deliverable Name: HP ProLiant SL335s G7 System ROM - A24 Release Date: 12/08/2012 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 09/01/2012 Firmware Dependencies: None Enhancements/New Features: Optimized the memory settings to improve the reliability of the memory system. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). Problems Fixed: Resolved an issue that could result in a server reset or the inability to boot. Servers should be updated to this revision of the system ROM to minimize the potential for a system reset or the inability to boot. Resolved an issue where industry standard tools, operating systems, and HP utilities may report less Level 3 (L3) cache than expected. Resolved a rare issue where the system and IML may indicate an uncorrectable reset when upgrading to the 09/01/2012 system ROM. Known Issues: 148 None Fixes HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved an issue that could result in a server reset or the inability to boot. Servers should be updated to this revision of the system ROM to minimize the potential for a system reset or the inability to boot. Resolved an issue where industry standard tools, operating systems, and HP utilities may report less Level 3 (L3) cache than expected. Resolved a rare issue where the system and IML may indicate an uncorrectable reset when upgrading to the 09/01/2012 system ROM. Known Issues: None Enhancements Optimized the memory settings to improve the reliability of the memory system. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). Online ROM Flash Component for Linux - HP ProLiant SL390s G7 (P69) Servers Version: 2013.07.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 149 Deliverable Name: HP ProLiant SL390s G7 System ROM - P69 HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults, general protection faults, or machine check exceptions or other unpredictable system behavior. While all processors supported by this server have this issue, to be affected by this issue the server must be operating in a virtualized environment, have Intel Hyperthreading enabled, have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables, and have a guest OS utilizing 32-bit PAE Paging Mode. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM, this System ROM upgrade is considered a critical fix. Addressed an issue with the Intel Xeon Processor X5675, Intel Xeon Processor X5690, and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This issue does not impact any processors that are not listed above. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems, such as Linux RedHat 6.2, and IRQ Balancing enabled in the Operating System. As a result of this issue, software may lose interrupts, receive spurious interrupts or cause a network disconnect. 150 Known Issues: None HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults, general protection faults, or machine check exceptions or other unpredictable system behavior. While all processors supported by this server have this issue, to be affected by this issue the server must be operating in a virtualized environment, have Intel Hyperthreading enabled, have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables, and have a guest OS utilizing 32-bit PAE Paging Mode. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM, this System ROM upgrade is considered a critical fix. Addressed an issue with the Intel Xeon Processor X5675, Intel Xeon Processor X5690, and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This issue does not impact any processors that are not listed above. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems, such as Linux RedHat 6.2, and IRQ Balancing enabled in the Operating System. As a result of this issue, software may lose interrupts, receive spurious interrupts or cause a network disconnect. Known Issues: None 151 HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Online ROM Flash Component for Linux - HP ProLiant SL4540 Gen8 (P74) Servers Version: 2014.02.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL4540 Gen8 System ROM - P74 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2400 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. HP | Service Pack for ProLiant 2014.06.0 152 HP Service Pack for ProLiant 2014.06.0 Release Notes Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2400 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. HP | Service Pack for ProLiant 2014.06.0 153 HP Service Pack for ProLiant 2014.06.0 Release Notes Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Online ROM Flash Component for Linux - HP ProLiant SL4545 G7 (A31) Servers Version: 2013.11.02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL4545 G7 System ROM - A31 Release Date: 11/02/2013 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 06/05/2013 Firmware Dependencies: 154 None HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes Enhancements/New Features: Added the latest product names of optional expansion cards in the ROM-Based Setup Utility (RBSU). Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards in the ROM-Based Setup Utility (RBSU). Known Issues: None Online ROM Flash Component for Linux - HP ProLiant XL220a Gen8 v2 (P94) Servers Version: 2014.04.29 (B) (Recommended) Important Note! Important Notes: None Deliverable Name: HP ProLiant XL220a Gen8 v2 System ROM - P94 155 Release Date: HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes 04/29/2014 Last Recommended or Critical Revision: This is the initial version of the firmware. Previous Revision: This is the initial version of the firmware. Firmware Dependencies: None Enhancements/New Features: This is the initial version of the firmware. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: This is the initial version of the firmware. Known Issues: None Online ROM Flash Component for VMware ESXi - HP ProLiant BL420c Gen8 (I30) Servers Version: 2014.02.10 (Optional) HP | Service Pack for ProLiant 2014.06.0 156 HP Service Pack for ProLiant 2014.06.0 Release Notes Important Note! Important Notes: None Deliverable Name: HP ProLiant BL420c Gen8 System ROM - I30 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Improved the power allocation logic for servers configured with Intel Xeon E5-2400 v2 series processors to more accurately determine the server's maximum power usage. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2400 v2 series processors than was necessary. With this revision of the System ROM, the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. This change does not impact servers configured with Intel Xeon E5-2400 series processors. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2400 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the HP | Service Pack for ProLiant 2014.06.0 157 HP Service Pack for ProLiant 2014.06.0 Release Notes 11/12/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2400 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs, the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. 158 Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs, the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes servers configured with Intel Xeon E5-2400 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead, the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs, the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Improved the power allocation logic for servers configured with Intel Xeon E5-2400 v2 series processors to more accurately determine the server's maximum power usage. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2400 v2 series processors than was necessary. With this revision of the System ROM, the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. This change does not impact servers configured with Intel Xeon E5-2400 series processors. Online ROM Flash Component for VMware ESXi - HP ProLiant BL460c G7 (I27) Servers Version: 2013.07.02 (B) (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility, the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL460c G7 System ROM - I27 159 Release Date: HP | Service Pack for ProLiant 2014.06.0 to be affected by this issue the server must be operating in a virtualized environment. While all processors supported by this server have this issue.06. This issue does not impact any processors that are not listed above. general protection faults. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Due to the potential severity of the issue addressed in this revision of the System ROM. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.0 . and have a guest OS utilizing 32-bit PAE Paging Mode. have Intel Hyperthreading enabled. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and IRQ Balancing enabled in the Operating System.2. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Addressed an issue with the Intel Xeon Processor X5675. such as Linux RedHat 6. software may lose interrupts. or machine check exceptions or other unpredictable system behavior. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Known Issues: 160 None Fixes HP | Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. this System ROM upgrade is considered a critical fix. Intel Xeon Processor X5690.06.HP Service Pack for ProLiant 2014. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 Release Notes 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/03/2012 Firmware Dependencies: None Enhancements/New Features: None. receive spurious interrupts or cause a network disconnect. As a result of this issue. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. and IRQ Balancing enabled in the Operating System. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. As a result of this issue. general protection faults. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.0 161 .0 Release Notes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.06. Intel Xeon Processor X5690. While all processors supported by this server have this issue.hp. This issue does not impact any processors that are not listed above.www2.10 (Optional) HP | Service Pack for ProLiant 2014. Addressed an issue with the Intel Xeon Processor X5675. Due to the potential severity of the issue addressed in this revision of the System ROM.HP Service Pack for ProLiant 2014. Known Issues: None Online ROM Flash Component for VMware ESXi .2. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.06. such as Linux RedHat 6. receive spurious interrupts or cause a network disconnect.com/bizsupport/TechSupport/Document. or machine check exceptions or other unpredictable system behavior. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.02. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. to be affected by this issue the server must be operating in a virtualized environment. and have a guest OS utilizing 32-bit PAE Paging Mode. software may lose interrupts. have Intel Hyperthreading enabled. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.HP ProLiant BL460c/WS460c Gen8 (I31) Servers Version: 2014. this System ROM upgrade is considered a critical fix.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. 06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Improved the power allocation logic for servers configured with Intel Xeon E5-2600 v2 series processors to more accurately determine the server's maximum power usage. This change does not impact servers configured with Intel Xeon E5-2600 series processors. When this issue occurs.06.x on Intel Xeon E5-2600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.0 Release Notes Important Note! Important Notes: None Deliverable Name: HP ProLiant BL460c/WS460c Gen8 System ROM . This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.HP Service Pack for ProLiant 2014.I31 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.0 162 . the server might experience a Non-System Disk Error or not HP | Service Pack for ProLiant 2014. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2600 v2 series processors than was necessary. With this revision of the System ROM. the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. 06. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.HP Service Pack for ProLiant 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.0 163 . When this issue occurs. When this issue occurs. When the issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.x on Intel Xeon E5-2600 series v2 processors. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. the NIC will not PXE boot or be identified or used by the operating system.0 Release Notes boot the intended media. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. the server will indicate an early boot progress of 20% and a "Memory and HP | Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Instead. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06. When the issue occurs.0 Release Notes QPI Link Initialization Start" message will be displayed on the screen output. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2600 v2 series processors than was necessary.06. the NIC will not PXE boot or be identified or used by the operating system.HP Service Pack for ProLiant 2014. This change does not impact servers configured with Intel Xeon E5-2600 series processors. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Instead.06.A19 Release Date: 02/02/2014 164 Last Recommended or Critical Revision: 12/08/2012 HP | Service Pack for ProLiant 2014. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). With this revision of the System ROM. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL465c G7 System ROM . Improved the power allocation logic for servers configured with Intel Xeon E5-2600 v2 series processors to more accurately determine the server's maximum power usage.02. Online ROM Flash Component for VMware ESXi . This issue does not impact servers configured with Intel Xeon E5-2600 series processors.HP ProLiant BL465c G7 (A19) Servers Version: 2014.0 . 06.0 Release Notes Previous Revision: 12/08/2012 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.02.HP ProLiant BL465c Gen8 (A26) Servers Version: 2014.06. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors. Known Issues: None Online ROM Flash Component for VMware ESXi .HP Service Pack for ProLiant 2014.0 .06 (Optional) Important Note! 165 Important Notes: None HP | Service Pack for ProLiant 2014. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. This issue did not impact any other revisions of the System ROM. When this issue occurs.HP Service Pack for ProLiant 2014.A26 Release Date: 02/06/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 11/02/2013 Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). the server might experience a Non-System Disk Error or not boot the intended media. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active.0 Release Notes Deliverable Name: HP ProLiant BL465c Gen8 System ROM .0 . Known Issues: None 166 Fixes Important Notes: HP | Service Pack for ProLiant 2014. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision.06.06. Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters. Online ROM Flash Component for VMware ESXi .jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP | Service Pack for ProLiant 2014.HP ProLiant BL490c G7 (I28) Servers Version: 2013. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision.06. the server might experience a Non-System Disk Error or not boot the intended media.com/bizsupport/TechSupport/Document. This issue did not impact any other revisions of the System ROM.www2.06.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.07.0 167 . The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active.02 (B) (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Known Issues: None Enhancements Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).hp. When this issue occurs. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 Release Notes None Firmware Dependencies: None Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. As a result of this issue. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and have a guest OS utilizing 32-bit PAE Paging Mode. Due to the potential severity of the issue addressed in this revision of the System ROM.0 168 . Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Intel Xeon Processor X5690. and IRQ Balancing enabled in the Operating System. have Intel Hyperthreading enabled.06. such as Linux RedHat 6.2.HP Service Pack for ProLiant 2014.06. to be affected by this issue the server must be operating in a virtualized environment. general protection faults. this System ROM upgrade is considered a critical fix. HP | Service Pack for ProLiant 2014. software may lose interrupts. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. or machine check exceptions or other unpredictable system behavior.I28 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/03/2012 Firmware Dependencies: None Enhancements/New Features: None. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.0 Release Notes HP ProLiant BL490c G7 System ROM . This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. receive spurious interrupts or cause a network disconnect. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. While all processors supported by this server have this issue. This issue does not impact any processors that are not listed above. Addressed an issue with the Intel Xeon Processor X5675. receive spurious interrupts or cause a network disconnect. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. such as Linux RedHat 6.06. 169 Known Issues: None HP | Service Pack for ProLiant 2014. and have a guest OS utilizing 32-bit PAE Paging Mode. Addressed an issue with the Intel Xeon Processor X5675.0 Release Notes Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This issue does not impact any processors that are not listed above. have Intel Hyperthreading enabled. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. As a result of this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Intel Xeon Processor X5690. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. or machine check exceptions or other unpredictable system behavior. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. this System ROM upgrade is considered a critical fix.06. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.HP Service Pack for ProLiant 2014.0 .jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. to be affected by this issue the server must be operating in a virtualized environment. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. and IRQ Balancing enabled in the Operating System. general protection faults.hp.www2. software may lose interrupts.2.com/bizsupport/TechSupport/Document. While all processors supported by this server have this issue. 06.0 170 .0 Release Notes Online ROM Flash Component for VMware ESXi . This issue HP | Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.HP ProLiant BL660c Gen8 (I32) Servers Version: 2014.I32 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL660c Gen8 System ROM . Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-4600 v2 series processors than was necessary. the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. This change does not impact servers configured with Intel Xeon E5-4600 series processors.02. Improved the power allocation logic for servers configured with Intel Xeon E5-4600 v2 series processors to more accurately determine the server's maximum power usage.x on Intel Xeon E5-4600 series v2 processors. With this revision of the System ROM. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06. the server might experience a Non-System Disk Error or not boot the intended media. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Instead. but might impact other operating systems. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.x on Intel Xeon E5-4600 series v2 processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting).06. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.0 Release Notes does NOT affect servers configured with the Intel Xeon E5-4600 series processors. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs. This issue does not impact servers configured with Intel Xeon E5-4600 series processors.06.HP Service Pack for ProLiant 2014. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors. When this issue occurs. This issue was originally seen with servers configured with Microsoft Windows Server 2012.0 171 . When the issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. HP | Service Pack for ProLiant 2014. the NIC will not PXE boot or be identified or used by the operating system. Online ROM Flash Component for VMware ESXi . This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When this issue occurs.01 (B) (Critical) 172 Important Note! HP | Service Pack for ProLiant 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. With this revision of the System ROM. Instead.06. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting). the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations.0 Release Notes Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When the issue occurs.07. This issue was originally seen with servers configured with Microsoft Windows Server 2012. This change does not impact servers configured with Intel Xeon E5-4600 series processors. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-4600 v2 series processors than was necessary. When this issue occurs. the NIC will not PXE boot or be identified or used by the operating system. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).0 . This issue does not impact servers configured with Intel Xeon E5-4600 series processors. but might impact other operating systems. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.HP ProLiant BL680c G7/BL620c G7 (I25) Servers Version: 2013.HP Service Pack for ProLiant 2014. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the server might experience a Non-System Disk Error or not boot the intended media. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Improved the power allocation logic for servers configured with Intel Xeon E5-4600 v2 series processors to more accurately determine the server's maximum power usage.06. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. to be affected by this issue the server must be operating in a virtualized environment. Due to the potential severity of the issue addressed in this revision of the System ROM. Known Issues: None 173 Fixes HP | Service Pack for ProLiant 2014.06. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. While all processors supported by this server have this issue. this System ROM upgrade is considered a critical fix. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 . or machine check exceptions or other unpredictable system behavior.0 Release Notes Important Notes: None Deliverable Name: HP ProLiant BL620c/BL680c G7 System ROM .I25 Release Date: 07/01/2013 Last Recommended or Critical Revision: 07/01/2013 Previous Revision: 04/01/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. and have a guest OS utilizing 32-bit PAE Paging Mode. have Intel Hyperthreading enabled.06.HP Service Pack for ProLiant 2014. general protection faults. 06. and have a guest OS utilizing 32-bit PAE Paging Mode. to be affected by this issue the server must be operating in a virtualized environment.HP Service Pack for ProLiant 2014. Due to the potential severity of the issue addressed in this revision of the System ROM. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 . have Intel Hyperthreading enabled. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06.0 Release Notes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. general protection faults. While all processors supported by this server have this issue.HP ProLiant BL685c G7 (A20) Servers Version: 2014. or machine check exceptions or other unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.02. Known Issues: None Online ROM Flash Component for VMware ESXi .01 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL685c G7 System ROM Release Date: 02/01/2014 174 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014. this System ROM upgrade is considered a critical fix. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.06. This issue did not impact any other revisions of the System ROM.0 Release Notes 12/17/2012 Previous Revision: 06/04/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.HP Service Pack for ProLiant 2014. This issue did not impact any other revisions of the System ROM. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. Known Issues: None 175 HP | Service Pack for ProLiant 2014.0 .06. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.02. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.x on Intel Xeon E5-2600 series v2 processors.HP ProLiant DL160 Gen8 (J03) Servers Version: 2014. HP | Service Pack for ProLiant 2014.06. When this issue occurs.0 176 .0 Release Notes Online ROM Flash Component for VMware ESXi .10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL160 Gen8 System ROM .HP Service Pack for ProLiant 2014. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.06.J03 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. When this issue occurs. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.x on Intel Xeon E5-2600 series v2 processors. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When the issue occurs. Instead. the NIC will not PXE boot or be identified or used by the operating system. When this issue occurs. HP | Service Pack for ProLiant 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.HP Service Pack for ProLiant 2014. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does not impact servers configured with Intel Xeon E5-2600 series processors. When this issue occurs.0 177 . Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.06. the server might experience a Non-System Disk Error or not boot the intended media.0 Release Notes Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.06. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the NIC will not PXE boot or be identified or used by the operating system. Instead.09 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL320e Gen8 System ROM . the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).0 Release Notes Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.HP ProLiant DL320e Gen8 (J05) Servers Version: 2013. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).06. When the issue occurs.11. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.HP Service Pack for ProLiant 2014.J05 Release Date: 11/09/2013 Last Recommended or Critical Revision: 08/24/2013 Previous Revision: 08/24/2013 Firmware Dependencies: 178 None HP | Service Pack for ProLiant 2014. Online ROM Flash Component for VMware ESXi .0 .06. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). HP | Service Pack for ProLiant 2014. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. 30. Previously.06. the system must be using Integrated Lights-Out (iLO) Firmware version 1. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. the Power-On Delay Option will function as if the No Delay option were chosen. Previously. For these new selections to function. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). If the system is configured to one of the new options without having iLO Firmware version 1. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. This allows the System ROM to attempt to boot the next device in the boot order. In some cases.20 or later.HP Service Pack for ProLiant 2014. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives.0 179 .20 or later. the Power-On Delay Option will function as if the No Delay option were chosen.20 or later. In some cases. This allows the System ROM to attempt to boot the next device in the boot order.0 Release Notes Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15.06. the system must be using Integrated Lights-Out (iLO) Firmware version 1. If the system is configured to one of the new options without having iLO Firmware version 1.20 or later. For these new selections to function. 30. 03. Known Issues: None Online ROM Flash Component for VMware ESXi .P80 Release Date: 03/28/2014 Last Recommended or Critical Revision: 03/07/2014 Previous Revision: 03/07/2014 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed an issue where servers using the 03/07/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test.0 180 .HP ProLiant DL320e Gen8 v2 (P80) Servers Version: 2014.06. HP | Service Pack for ProLiant 2014. This problem only affects servers with the 03/07/2014 revision of the System ROM.28 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL320e Gen8 v2 System ROM .HP Service Pack for ProLiant 2014. This issue has no known impact with TPM functionality under normal operating system environments.06.0 Release Notes Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). 07.HP Service Pack for ProLiant 2014.hp.0 Release Notes Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where servers using the 03/07/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test. Known Issues: None Online ROM Flash Component for VMware ESXi . This problem only affects servers with the 03/07/2014 revision of the System ROM.P68 Release Date: HP | Service Pack for ProLiant 2014. This issue has no known impact with TPM functionality under normal operating system environments.com/bizsupport/TechSupport/Document.HP ProLiant DL360 G7 (P68) Servers Version: 2013.0 .www2.06.02 (B) (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: 181 HP ProLiant DL360 G7 System ROM .06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Intel Xeon Processor X5690. As a result of this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Due to the potential severity of the issue addressed in this revision of the System ROM. such as Linux RedHat 6. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does not impact any processors that are not listed above. this System ROM upgrade is considered a critical fix. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. and have a guest OS utilizing 32-bit PAE Paging Mode. and IRQ Balancing enabled in the Operating System.HP Service Pack for ProLiant 2014.0 .2.06. or machine check exceptions or other unpredictable system behavior. to be affected by this issue the server must be operating in a virtualized environment.06. general protection faults. software may lose interrupts. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. Addressed an issue with the Intel Xeon Processor X5675. have Intel Hyperthreading enabled. receive spurious interrupts or cause a network disconnect. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. While all processors supported by this server have this issue. Known Issues: 182 None Fixes HP | Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.0 Release Notes 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. 0 183 .HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.hp.2. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. As a result of this issue. Addressed an issue with the Intel Xeon Processor X5675. and IRQ Balancing enabled in the Operating System. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. such as Linux RedHat 6. Intel Xeon Processor X5690.0 Release Notes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.02. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. While all processors supported by this server have this issue. this System ROM upgrade is considered a critical fix.www2.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.06. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.10 (Optional) HP | Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. receive spurious interrupts or cause a network disconnect. or machine check exceptions or other unpredictable system behavior. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.HP ProLiant DL360e Gen8/DL380e Gen8 (P73) Servers Version: 2014. Due to the potential severity of the issue addressed in this revision of the System ROM. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This issue does not impact any processors that are not listed above. Known Issues: None Online ROM Flash Component for VMware ESXi . general protection faults. have Intel Hyperthreading enabled. software may lose interrupts. to be affected by this issue the server must be operating in a virtualized environment. and have a guest OS utilizing 32-bit PAE Paging Mode.06. When this issue occurs. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 184 . Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.0 Release Notes Important Note! Important Notes: None Deliverable Name: HP ProLiant DL360e/DL380e Gen8 System ROM .HP Service Pack for ProLiant 2014. When this issue occurs.06.P73 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the server might experience a Non-System Disk Error or not boot the intended media. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. This issue does not impact HP | Service Pack for ProLiant 2014.x on Intel Xeon E5-2400 series v2 processors.06. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot HP | Service Pack for ProLiant 2014. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Instead. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.0 . the NIC will not PXE boot or be identified or used by the operating system. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.06.x on Intel Xeon E5-2400 series v2 processors. When this issue occurs. 185 Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.06.0 Release Notes servers configured with Intel Xeon E5-2400 series processors. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. Instead. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. P71 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None. 186 Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).06.06. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs. Online ROM Flash Component for VMware ESXi .0 Release Notes devices in the order specified by the Standard Boot Order (IPL). HP | Service Pack for ProLiant 2014.HP ProLiant DL360p Gen8/DL360p Gen8 SE (P71) Servers Version: 2014. the NIC will not PXE boot or be identified or used by the operating system.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL360p Gen8/DL360p Gen8 SE System ROM .0 .02.HP Service Pack for ProLiant 2014. HP Service Pack for ProLiant 2014. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue is not unique to HP ProLiant servers and HP | Service Pack for ProLiant 2014. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.06. Instead.0 Release Notes Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. When this issue occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). When the issue occurs. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. the server might experience a Non-System Disk Error or not boot the intended media.0 . Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. 187 Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.x on Intel Xeon E5-2600 series v2 processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. the NIC will not PXE boot or be identified or used by the operating system.x on Intel Xeon E5-2600 series v2 processors. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. When this issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).com/bizsupport/TechSupport/Document.06. When this issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Online ROM Flash Component for VMware ESXi .07. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the NIC will not PXE boot or be identified or used by the operating system. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.HP ProLiant DL380 G7 (P67) Servers Version: 2013. When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.hp.02 (B) (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 Release Notes could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 188 .HP Service Pack for ProLiant 2014. Instead. When the issue occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.06.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. 06. and have a guest OS utilizing 32-bit PAE Paging Mode.0 189 . this System ROM upgrade is considered a critical fix. receive spurious interrupts or cause a network HP | Service Pack for ProLiant 2014.P67 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. While all processors supported by this server have this issue. This issue does not impact any processors that are not listed above. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. Addressed an issue with the Intel Xeon Processor X5675. Due to the potential severity of the issue addressed in this revision of the System ROM. general protection faults.0 Release Notes Deliverable Name: HP ProLiant DL380 G7 System ROM . This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. such as Linux RedHat 6. to be affected by this issue the server must be operating in a virtualized environment. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.2. As a result of this issue.06. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. or machine check exceptions or other unpredictable system behavior. and IRQ Balancing enabled in the Operating System. Intel Xeon Processor X5690. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.HP Service Pack for ProLiant 2014. have Intel Hyperthreading enabled. software may lose interrupts. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.2. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. general protection faults. Due to the potential severity of the issue addressed in this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. and have a guest OS utilizing 32-bit PAE Paging Mode. have Intel Hyperthreading enabled.06. Addressed an issue with the Intel Xeon Processor X5675. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.hp. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. to be affected by this issue the server must be operating in a virtualized environment. software may lose interrupts. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 190 . This issue does not impact any processors that are not listed above. or machine check exceptions or other unpredictable system behavior.www2. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. While all processors supported by this server have this issue. receive spurious interrupts or cause a network disconnect. Known Issues: HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. As a result of this issue.0 Release Notes disconnect.06. such as Linux RedHat 6. this System ROM upgrade is considered a critical fix. and IRQ Balancing enabled in the Operating System. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Intel Xeon Processor X5690. 0 Release Notes None Online ROM Flash Component for VMware ESXi . Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).x on Intel Xeon E5-2600 series v2 processors.P70 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None.HP Service Pack for ProLiant 2014. When this issue occurs.02.HP ProLiant DL380p Gen8 (P70) Servers Version: 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.06.0 191 .10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL380p Gen8 System ROM .06. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. the server might experience a Non-System Disk Error or not HP | Service Pack for ProLiant 2014. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the server might experience a Non-System Disk Error or not boot the intended media.0 192 .0 Release Notes boot the intended media.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When this issue occurs.x on Intel Xeon E5-2600 series v2 processors. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the NIC will not PXE boot or be identified or used by the operating system. When this issue occurs. When this issue occurs. When the issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Instead.HP Service Pack for ProLiant 2014. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.06. the server will indicate an early boot progress of 20% and a "Memory and HP | Service Pack for ProLiant 2014. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).A18 Release Date: 02/02/2014 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 193 12/08/2012 Firmware Dependencies: HP | Service Pack for ProLiant 2014.06.HP ProLiant DL385 G7 (A18) Servers Version: 2014. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).HP Service Pack for ProLiant 2014. Instead. the NIC will not PXE boot or be identified or used by the operating system. Online ROM Flash Component for VMware ESXi .06.0 Release Notes QPI Link Initialization Start" message will be displayed on the screen output. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL385 G7 System ROM . This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs.0 .02. Known Issues: None Online ROM Flash Component for VMware ESXi . Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.02.06.06.HP Service Pack for ProLiant 2014.0 .06 (Optional) Important Note! Important Notes: None 194 Deliverable Name: HP ProLiant DL385p Gen8 System ROM .0 Release Notes None Enhancements/New Features: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.HP ProLiant DL385p Gen8 (A28) Servers Version: 2014.A28 HP | Service Pack for ProLiant 2014. When this issue occurs. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.0 Release Notes Release Date: 02/06/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 11/02/2013 Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). Known Issues: None Fixes Important Notes: None 195 Firmware Dependencies: None HP | Service Pack for ProLiant 2014. This issue did not impact any other revisions of the System ROM.0 . Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active.06. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters. the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision.06.HP Service Pack for ProLiant 2014. P77 Release Date: 02/10/2014 Last Recommended or Critical Revision: 196 12/20/2013 HP | Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.0 . This issue did not impact any other revisions of the System ROM.HP Service Pack for ProLiant 2014.02.06.06. Known Issues: None Enhancements Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.0 Release Notes Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision.HP ProLiant DL560 Gen8 (P77) Servers Version: 2014. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active. Online ROM Flash Component for VMware ESXi .10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL560 Gen8 System ROM . When this issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.HP Service Pack for ProLiant 2014. This issue does not impact servers configured with Intel Xeon E5-4600 series processors.0 Release Notes Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Known Issues: None HP | Service Pack for ProLiant 2014. the NIC will not PXE boot or be identified or used by the operating system. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting).0 197 . Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the server might experience a Non-System Disk Error or not boot the intended media. but might impact other operating systems. This issue was originally seen with servers configured with Microsoft Windows Server 2012. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Instead.06. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When the issue occurs. When this issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.x on Intel Xeon E5-4600 series v2 processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).06. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. 0 Release Notes Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. When the issue occurs. This issue does not impact servers configured with Intel Xeon E5-4600 series processors.x on Intel Xeon E5-4600 series v2 processors. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. When this issue occurs.0 . the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. When this issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.06. 198 Known Issues: None HP | Service Pack for ProLiant 2014. This issue was originally seen with servers configured with Microsoft Windows Server 2012. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting). Instead. the NIC will not PXE boot or be identified or used by the operating system. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. but might impact other operating systems.HP Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. 2013. it is not necessary to update to ver.10.0 Release Notes Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). 2013.10.10. the HP | Service Pack for ProLiant 2014.01(B).01.01(B) did not change as compared to ver.10. Deliverable Name: HP ProLiant DL580 G7 System ROM . If using BIOS Firmware ver 2013. All HP ProLiant DL580 G7 servers should update to the 10/01/2013 System ROM instead.01 (B) (Critical) Important Note! Important Notes: IMPORTANT: The 07/01/2013 System ROM has an issue that can result in reduced performance and it has been removed from the HP Support Site. Due to an issue with the thermal solution included in that revision of the System ROM. The actual BIOS Firmware contained within ver.HP ProLiant DL580 G7 (P65) Servers Version: 2013. 2013.HP Service Pack for ProLiant 2014. The 10/01/2013 System ROM revision addresses the performance issue.06. The performance issue was unique to the 07/01/2013 System ROM revision for the DL580 G7.01. It does not affect any other ProLiant servers or any other HP ProLiant DL580 G7 System ROM revisions.10.P65 Release Date: 10/01/2013 Last Recommended or Critical Revision: 10/01/2013 Previous Revision: 04/01/2013 Firmware Dependencies: None Enhancements/New Features: None 199 Problems Fixed: Addressed an issue with the 07/01/2013 revision of the System ROM that could result in decreased performance. Online ROM Flash Component for VMware ESXi .0 .06. the processor may be "throttled" to a reduced frequency when not necessary. 2013. All HP ProLiant DL580 G7 servers should update to the 10/01/2013 System ROM instead. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. have Intel HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. and have a guest OS utilizing 32-bit PAE Paging Mode. have Intel Hyperthreading enabled.06. or machine check exceptions or other unpredictable system behavior. This issue does NOT affect other revisions of the System ROM.0 Release Notes processor may be "throttled" to a reduced frequency when not necessary. it is not necessary to update to ver.01(B) did not change as compared to ver. The 10/01/2013 System ROM revision addresses the performance issue. to be affected by this issue the server must be operating in a virtualized environment. The actual BIOS Firmware contained within ver. or machine check exceptions or other unpredictable system behavior.10. Due to the potential severity of the issue addressed in this revision of the System ROM. to be affected by this issue the server must be operating in a virtualized environment. While all processors supported by this server have this issue.10. this System ROM upgrade is considered a critical fix.10.01. It does not affect any other ProLiant servers or any other HP ProLiant DL580 G7 System ROM revisions.01. Firmware Dependencies: None Problems Fixed: Addressed an issue with the 07/01/2013 revision of the System ROM that could result in decreased performance. If using BIOS Firmware ver 2013. Known Issues: None Fixes Important Notes: IMPORTANT: The 07/01/2013 System ROM has an issue that can result in reduced performance and it has been removed from the HP Support Site.0 200 . general protection faults.01(B). This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.06. Due to an issue with the thermal solution included in that revision of the System ROM. The performance issue was unique to the 07/01/2013 System ROM revision for the DL580 G7. 2013. While all processors supported by this server have this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. general protection faults. Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Addressed an issue where the Intelligent Platform Management Interface (IPMI) based power reporting would not function properly and report an incorrect wattage from the installed Power Supplies. 2013. This issue does NOT affect other revisions of the System ROM.10. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Addressed an issue where the Intelligent Platform Management Interface (IPMI) based power reporting would not function properly and report an incorrect wattage from the installed Power Supplies.02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL585 G7 System ROM Release Date: 02/02/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 06/04/2013 Firmware Dependencies: None 201 Enhancements/New Features: None HP | Service Pack for ProLiant 2014.0 Release Notes Hyperthreading enabled.02.0 .HP ProLiant DL585 G7 (A16) Servers Version: 2014.06.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. and have a guest OS utilizing 32-bit PAE Paging Mode. Known Issues: None Online ROM Flash Component for VMware ESXi .HP Service Pack for ProLiant 2014. this System ROM upgrade is considered a critical fix. Due to the potential severity of the issue addressed in this revision of the System ROM. HP ProLiant DL980 G7 (P66) Servers Version: 2013.31 (Recommended) Important Note! HP | Service Pack for ProLiant 2014. In some cases Operating Systems might report errors. This issue did not impact any other revisions of the System ROM. this issue might cause some versions of Microsoft Windows to boot into Recovery Mode. The instability could result in unexpected resets with Uncorrectable Chipset errors reported in the Integrated Management Log (IML). Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. this issue might cause some versions of Microsoft Windows to boot into Recovery Mode.HP Service Pack for ProLiant 2014. In some cases Operating Systems might report errors.06.0 202 . Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved an issue where the HP NC375i Integrated Quad Port Gigabit Adapter could cause system instability.0 Release Notes Problems Fixed: Resolved an issue where the HP NC375i Integrated Quad Port Gigabit Adapter could cause system instability. This issue did not impact any other revisions of the System ROM. Known Issues: None Online ROM Flash Component for VMware ESXi .12. In addition. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. In addition. The instability could result in unexpected resets with Uncorrectable Chipset errors reported in the Integrated Management Log (IML).06. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. this issue would typically be seen on every warm reboot. Address 0x00000023'7B6E25C0. Updated the embedded PXE Firmware to gPXE Version 4. Addressed an extremely rare issue where the system might stop responding and reboot unexpectedly during an Operating System boot or run time.582.0 via PXE.0 Release Notes Important Notes: None Deliverable Name: HP ProLiant DL980 G7 System ROM . Status 0xF6000000'00000972. TPM does not work in an Operation System after a system boot. APIC ID 0x00000040. Problems Fixed: Addressed an issue where the system may delay to POST or fail to boot when the TPM (Trusted Platform Module) is enabled.HP Service Pack for ProLiant 2014. Customers who experience this event need to update to this version of the System ROM before contacting HP Support. which will improve the system memory's RAS (Reliability.0 203 .0. Known Issues: None HP | Service Pack for ProLiant 2014. This error would typically be seen with a lot of following IML information: Uncorrectable Machine Check Exception (Board 0. Processor 2.06.06. and reports a lot of Uncorrectable Machine Check Event in the IML (Integrated Management Log). Misc 0x00000000'00000000).P66 Release Date: 12/31/2013 Last Recommended or Critical Revision: 12/31/2013 Previous Revision: 07/29/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the DDDC (Double Device Data Correction) aware POST (Power On Self Test) feature. Availability and Serviceability). This firmware addresses an issue where the system might stop responding during the deployment of VMware Vcenter 5. Bank 0x0000000E. Known Issues: None Enhancements Added support for the DDDC (Double Device Data Correction) aware POST (Power On Self Test) feature.582.11. TPM does not work in an Operation System after a system boot. This error would typically be seen with a lot of following IML information: Uncorrectable Machine Check Exception (Board 0. Misc 0x00000000'00000000). which will improve the system memory's RAS (Reliability.HP ProLiant MicroServer Gen8 (J06) Servers Version: 2013. Address 0x00000023'7B6E25C0.0. this issue would typically be seen on every warm reboot. Updated the embedded PXE Firmware to gPXE Version 4.0 Release Notes Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where the system may delay to POST or fail to boot when the TPM (Trusted Platform Module) is enabled. Online ROM Flash Component for VMware ESXi . Processor 2.09 (Optional) Important Note! Important Notes: None 204 Deliverable Name: HP | Service Pack for ProLiant 2014.0 . Customers who experience this event need to update to this version of the System ROM before contacting HP Support. Status 0xF6000000'00000972. This firmware addresses an issue where the system might stop responding during the deployment of VMware Vcenter 5. Bank 0x0000000E. APIC ID 0x00000040.HP Service Pack for ProLiant 2014.06. Availability and Serviceability).06.0 via PXE. and reports a lot of Uncorrectable Machine Check Event in the IML (Integrated Management Log). Addressed an extremely rare issue where the system might stop responding and reboot unexpectedly during an Operating System boot or run time. 06. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay).J06 Release Date: 11/09/2013 Last Recommended or Critical Revision: 08/24/2013 Previous Revision: 08/24/2013 Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15.HP Service Pack for ProLiant 2014.0 . 30. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device.20 or later.0 Release Notes HP ProLiant MicroServer Gen8 System ROM . This allows the System ROM to attempt to boot the next device in the boot order. If the system is configured to one of the new options without having iLO Firmware version 1. Previously. the Power-On Delay Option will function as if the No Delay option were chosen. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. the system must be using Integrated Lights-Out (iLO) Firmware version 1. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). In some cases. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error.20 or later. For these new selections to function. Problems Fixed: None Known Issues: None Enhancements Important Notes: 205 None HP | Service Pack for ProLiant 2014.06. 30. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).09 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML310e Gen8 System ROM . 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). Known Issues: None Online ROM Flash Component for VMware ESXi . Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. This allows the System ROM to attempt to boot the next device in the boot order. If the system is configured to one of the new options without having iLO Firmware version 1. In some cases.06.0 . the Power-On Delay Option will function as if the No Delay option were chosen.HP ProLiant ML310e Gen8 (J04) Servers Version: 2013.HP Service Pack for ProLiant 2014.0 Release Notes Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15.11.J04 Release Date: 11/09/2013 206 Last Recommended or Critical Revision: 08/24/2013 HP | Service Pack for ProLiant 2014. For these new selections to function. the system must be using Integrated Lights-Out (iLO) Firmware version 1.06.20 or later.20 or later. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. Previously. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. 30.0 207 .20 or later. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. For these new selections to function.0 Release Notes Previous Revision: 08/24/2013 Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. the Power-On Delay Option will function as if the No Delay option were chosen. HP | Service Pack for ProLiant 2014. If the system is configured to one of the new options without having iLO Firmware version 1. the Power-On Delay Option will function as if the No Delay option were chosen. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). For these new selections to function. If the system is configured to one of the new options without having iLO Firmware version 1. In some cases. the system must be using Integrated Lights-Out (iLO) Firmware version 1.06.HP Service Pack for ProLiant 2014. Previously. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives.20 or later. the system must be using Integrated Lights-Out (iLO) Firmware version 1.06.20 or later. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15.20 or later. This allows the System ROM to attempt to boot the next device in the boot order. 30. Previously. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error.HP Service Pack for ProLiant 2014.06.03.HP ProLiant ML310e Gen8 v2 (P78) Servers Version: 2014.0 Release Notes Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. Known Issues: None Online ROM Flash Component for VMware ESXi .0 .P78 Release Date: 03/28/2014 Last Recommended or Critical Revision: 03/08/2014 Previous Revision: 03/08/2013 Firmware Dependencies: None 208 Enhancements/New Features: None HP | Service Pack for ProLiant 2014. This allows the System ROM to attempt to boot the next device in the boot order.06. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).28 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML310e Gen8 v2 System ROM . the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. In some cases. HP Service Pack for ProLiant 2014. This issue has no known impact with TPM functionality under normal operating system environments.06.0 .06.02.HP ProLiant ML350e Gen8/ML350e Gen8 v2 (J02) Servers Version: 2014.0 Release Notes Problems Fixed: Addressed an issue where servers using the 03/08/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test.10 (Optional) Important Note! Important Notes: None Deliverable Name: 209 HP ProLiant ML350e Gen8/ML350e Gen8 v2 System ROM .J02 HP | Service Pack for ProLiant 2014. This problem only affects servers with the 03/08/2014 revision of the System ROM. Known Issues: None Online ROM Flash Component for VMware ESXi . This issue has no known impact with TPM functionality under normal operating system environments. This problem only affects servers with the 03/08/2014 revision of the System ROM. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where servers using the 03/08/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.0 210 . Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.HP Service Pack for ProLiant 2014.0 Release Notes Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/22/2013 Previous Revision: 12/22/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).06.x on Intel Xeon E5-2400 series v2 processors. Addressed an issue where servers using the 11/12/2013 or 12/22/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the NIC will not PXE boot or be identified or used by the HP | Service Pack for ProLiant 2014.06. Instead. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. When this issue occurs. When this issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/22/2013 revisions. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. the server might experience a Non-System Disk Error or not boot the intended media. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. When the issue occurs. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.0 Release Notes operating system.06. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/22/2013 revisions. the server might experience a Non-System Disk Error or not boot the intended media. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the NIC will not PXE boot or be identified or used by the operating system.HP Service Pack for ProLiant 2014. 211 Known Issues: None HP | Service Pack for ProLiant 2014.06.0 . Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Instead. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. When this issue occurs.x on Intel Xeon E5-2400 series v2 processors. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/22/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When the issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). 06.06.x on Intel Xeon E5-2600 series v2 processors.HP ProLiant ML350p Gen8 (P72) Servers Version: 2014. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.0 Release Notes Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).P72 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None. Online ROM Flash Component for VMware ESXi .10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML350p Gen8 System ROM . Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.HP Service Pack for ProLiant 2014.0 212 .02. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is HP | Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. When this issue occurs. When this issue occurs. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error HP | Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.HP Service Pack for ProLiant 2014.x on Intel Xeon E5-2600 series v2 processors. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When the issue occurs.06. When this issue occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.0 213 .0 Release Notes not marked as Active. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Instead. the NIC will not PXE boot or be identified or used by the operating system. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. the NIC will not PXE boot or be identified or used by the operating system. When this issue occurs.HP Service Pack for ProLiant 2014.P83 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 214 12/20/2013 HP | Service Pack for ProLiant 2014.0 .0 Release Notes occurs. Instead. When the issue occurs.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL210t Gen8 System ROM .06. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Online ROM Flash Component for VMware ESXi . Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.02. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).06.HP ProLiant SL210t Gen8 (P83) Servers Version: 2014. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). 06.0 Release Notes Firmware Dependencies: None. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. the NIC will not PXE boot or be identified or used by the operating system. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).06. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.0 . This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.x on Intel Xeon E5-2600 series v2 processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Known Issues: None Fixes Important Notes: 215 None HP | Service Pack for ProLiant 2014. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does not impact servers configured with Intel Xeon E5-2600 series processors.HP Service Pack for ProLiant 2014. When this issue occurs. Instead. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When this issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.02.10 (Optional) Important Note! HP | Service Pack for ProLiant 2014. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.HP ProLiant SL230s/SL250s/SL270s Gen8/SL270s Gen8 SE (P75) Servers Version: 2014.0 216 . This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Online ROM Flash Component for VMware ESXi . the server might experience a Non-System Disk Error or not boot the intended media. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.x on Intel Xeon E5-2600 series v2 processors.0 Release Notes Firmware Dependencies: None. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the NIC will not PXE boot or be identified or used by the operating system. Instead. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When this issue occurs. When the issue occurs.06. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.06. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.HP Service Pack for ProLiant 2014.0 217 .P75 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None. When this issue occurs. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the server might experience a Non-System Disk Error or not boot the intended media. When this issue occurs.06. This issue does not impact servers configured with Intel Xeon E5-2600 series processors.0 Release Notes Important Notes: None Deliverable Name: HP ProLiant SL230s/250s/270s Gen8/270s Gen8 SE System ROM . Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. HP | Service Pack for ProLiant 2014. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.x on Intel Xeon E5-2600 series v2 processors. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the NIC will not PXE boot or be identified or used by the operating system. Instead. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Instead.HP Service Pack for ProLiant 2014. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.06. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.0 Release Notes Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.06. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When this issue occurs.x on Intel Xeon E5-2600 series v2 processors. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None.0 218 . the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP HP | Service Pack for ProLiant 2014. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. When the issue occurs. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 219 .10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL4540 Gen8 System ROM .HP Service Pack for ProLiant 2014.06.06. Online ROM Flash Component for VMware ESXi . the NIC will not PXE boot or be identified or used by the operating system. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual HP | Service Pack for ProLiant 2014.02.HP ProLiant SL4540 Gen8 (P74) Servers Version: 2014.P74 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 Release Notes 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors.0 220 . Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.06. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. the NIC will not PXE boot or be identified or used by the operating system. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs. the server might experience a Non-System Disk Error or not boot the intended media. Instead.0 Release Notes machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. HP | Service Pack for ProLiant 2014. When the issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.x on Intel Xeon E5-2400 series v2 processors.06. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.x on Intel Xeon E5-2400 series v2 processors. When this issue occurs.HP Service Pack for ProLiant 2014. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the NIC will not PXE boot or be identified or used by the operating system. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.0 Release Notes Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.HP Service Pack for ProLiant 2014.11. When this issue occurs. When this issue occurs. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. When the issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.06.02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL4545 G7 System ROM . the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).A31 Release Date: 221 11/02/2013 HP | Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. Online ROM Flash Component for VMware ESXi .06. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).HP ProLiant SL4545 G7 (A31) Servers Version: 2013. Instead.0 . 29 (Recommended) Important Note! HP | Service Pack for ProLiant 2014.0 222 .06. Known Issues: None Online ROM Flash Component for VMware ESXi .04. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards in the ROM-Based Setup Utility (RBSU).HP Service Pack for ProLiant 2014.HP ProLiant XL220a Gen8 v2 (P94) Servers Version: 2014.0 Release Notes Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 06/05/2013 Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards in the ROM-Based Setup Utility (RBSU).06. HP Service Pack for ProLiant 2014.P94 Release Date: 04/29/2014 Last Recommended or Critical Revision: This is the initial version of the firmware.0 Release Notes Important Notes: None Deliverable Name: HP ProLiant XL220a Gen8 v2 System ROM . Previous Revision: This is the initial version of the firmware.0 .06. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: 223 None Enhancements/New Features: HP | Service Pack for ProLiant 2014. Firmware Dependencies: None Enhancements/New Features: This is the initial version of the firmware.06. 02_04-01-2014 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL580 Gen8 System ROM .01_03-19-2014 Previous Revision: 1.02_04-01-2014 Last Recommended or Critical Revision: 1. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014.0 224 .06.0 Release Notes This is the initial version of the firmware.01_03-19-2014 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on VMware ESX 5.P79 Release Version: 1. HP | Service Pack for ProLiant 2014.HP ProLiant DL580 Gen8 (P79) Servers Version: 1.06. Known Issues: None Online ROM Flash Component for VMware ESXi.x or Microsoft Hyper-V on Intel Xeon E7-4800 series v2 processors. 10.I20 Release Date: 10/25/2010 225 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014.x or Microsoft Hyper-V on Intel Xeon E7-4800 series v2 processors. Known Issues: None Online ROM Flash Component for Windows .0 Release Notes Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on VMware ESX 5. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06.06.HP Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed.25 (Critical) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL260c G5 System ROM .0 .HP ProLiant BL260c G5 (I20) Servers Version: 2010. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. Intel Xeon 5300-series. and Intel Xeon 5400-series processors. kernel panic. this System ROM upgrade is considered a critical fix. blue screen. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue. Intel Xeon 5200-series. blue screen.06.06. Due to the potential severity of the issue addressed in this revision of the System ROM. Intel Xeon 5300-series.0 226 . kernel panic.0 Release Notes 10/25/2010 Previous Revision: 04/26/2010 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. or other unpredictable system behavior. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. and Intel Xeon 5400-series processors. This issue is not unique to HP ProLiant servers and HP | Service Pack for ProLiant 2014. or other unpredictable system behavior. 0x00000000)". This issue affects platforms utilizing Intel Xeon 5100-series. HP strongly recommends immediate update to firmware revisions with required critical fixes. This issue affects platforms utilizing Intel Xeon 5100-series. Intel Xeon 5200-series.HP Service Pack for ProLiant 2014. 06. Due to the potential severity of the issue addressed in this revision of the System ROM.06.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Known Issues: None Online ROM Flash Component for Windows .07.0 . Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. 0x00000000)".hp.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL280c G6 System ROM .0 Release Notes could impact any system using affected processors.HP ProLiant BL280c G6 (I22) Servers Version: 2013.com/bizsupport/TechSupport/Document.I22 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 227 Firmware Dependencies: None HP | Service Pack for ProLiant 2014. HP strongly recommends immediate update to firmware revisions with required critical fixes. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. this System ROM upgrade is considered a critical fix.www2. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue. have Intel Hyperthreading enabled. receive spurious interrupts or cause a network disconnect. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. and have a guest OS utilizing 32-bit PAE Paging Mode. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Intel Xeon Processor X5690. Due to the potential severity of the issue addressed in this revision of the System ROM. to be affected by this issue the server must be operating in a virtualized environment.www2.0 Release Notes Enhancements/New Features: None. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.hp. This issue does not impact any processors that are not listed above. such as Linux RedHat 6. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06. general protection faults. this System ROM upgrade is considered a critical fix. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.2. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and IRQ Balancing enabled in the Operating System.0 228 . This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.06. Addressed an issue with the Intel Xeon Processor X5675. As a result of this issue. While all processors supported by this server have this issue.HP Service Pack for ProLiant 2014. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. software may lose interrupts. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None HP | Service Pack for ProLiant 2014. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. or machine check exceptions or other unpredictable system behavior.com/bizsupport/TechSupport/Document. 06. this System ROM upgrade is considered a critical fix.HP Service Pack for ProLiant 2014. software may lose interrupts. general protection faults. Addressed an issue with the Intel Xeon Processor X5675. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Intel Xeon Processor X5690. This issue does not impact any processors that are not listed above.06. to be affected by this issue the server must be operating in a virtualized environment. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. have Intel Hyperthreading enabled. As a result of this issue. or machine check exceptions or other unpredictable system behavior.I19 229 Release Date: HP | Service Pack for ProLiant 2014. and IRQ Balancing enabled in the Operating System. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.HP ProLiant BL2x220c G5 (I19) Servers Version: 2010. receive spurious interrupts or cause a network disconnect. and have a guest OS utilizing 32-bit PAE Paging Mode. such as Linux RedHat 6. Known Issues: None Online ROM Flash Component for Windows .10.25 (Critical) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL2x220c G5 System ROM . While all processors supported by this server have this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.0 . This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.2.0 Release Notes Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Due to the potential severity of the issue addressed in this revision of the System ROM. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue. Known Issues: None Fixes Important Notes: None Firmware Dependencies: 230 None Problems Fixed: HP | Service Pack for ProLiant 2014. or other unpredictable system behavior. this System ROM upgrade is considered a critical fix. and Intel Xeon 5400-series processors.06.0 Release Notes 10/25/2010 Last Recommended or Critical Revision: 10/25/2010 Previous Revision: 04/26/2010 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. kernel panic.0 .HP Service Pack for ProLiant 2014. Intel Xeon 5300-series. blue screen. Due to the potential severity of the issue addressed in this revision of the System ROM.06. HP strongly recommends immediate update to firmware revisions with required critical fixes. This issue affects platforms utilizing Intel Xeon 5100-series. 0x00000000)". Intel Xeon 5200-series. 0x00000000)".com/bizsupport/TechSupport/Document.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06. Intel Xeon 5200-series.hp.07. This issue is not unique to HP ProLiant servers and could impact any system using affected processors.0 . This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.I26 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 231 Previous Revision: HP | Service Pack for ProLiant 2014. This issue affects platforms utilizing Intel Xeon 5100-series.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL2x220c G6 System ROM . this System ROM upgrade is considered a critical fix. kernel panic. blue screen. Known Issues: None Online ROM Flash Component for Windows . Intel Xeon 5300-series.0 Release Notes Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error.HP Service Pack for ProLiant 2014.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. and Intel Xeon 5400-series processors. or other unpredictable system behavior.www2. HP strongly recommends immediate update to firmware revisions with required critical fixes.HP ProLiant BL2x220c G6 (I26) Servers Version: 2013. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. or machine check exceptions or other unpredictable system behavior. have Intel Hyperthreading enabled. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.com/bizsupport/TechSupport/Document. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and IRQ Balancing enabled in the Operating System. such as Linux RedHat 6. this System ROM upgrade is considered a critical fix. software may lose interrupts.0 Release Notes 05/05/2011 Firmware Dependencies: None Enhancements/New Features: None. As a result of this issue.hp. This issue does not impact any processors that are not listed above. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014.2.jsp?locale=en_US&objectID=c0283837 HP | Service Pack for ProLiant 2014. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Due to the potential severity of the issue addressed in this revision of the System ROM. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Addressed an issue with the Intel Xeon Processor X5675.06. and have a guest OS utilizing 32-bit PAE Paging Mode.0 232 . to be affected by this issue the server must be operating in a virtualized environment. While all processors supported by this server have this issue. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. general protection faults. Intel Xeon Processor X5690. receive spurious interrupts or cause a network disconnect. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. general protection faults. Known Issues: None Online ROM Flash Component for Windows . This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.06.0 Release Notes 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.HP Service Pack for ProLiant 2014. have Intel Hyperthreading enabled.HP ProLiant BL2x220c G7 (I29) Servers Version: 2013. Addressed an issue with the Intel Xeon Processor X5675. and have a guest OS utilizing 32-bit PAE Paging Mode. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 233 . this System ROM upgrade is considered a critical fix.07. Due to the potential severity of the issue addressed in this revision of the System ROM. such as Linux RedHat 6. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.06. software may lose interrupts. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. or machine check exceptions or other unpredictable system behavior. As a result of this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. to be affected by this issue the server must be operating in a virtualized environment. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory HP | Service Pack for ProLiant 2014.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Intel Xeon Processor X5690. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. While all processors supported by this server have this issue. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. receive spurious interrupts or cause a network disconnect. This issue does not impact any processors that are not listed above. and IRQ Balancing enabled in the Operating System. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.2. to be affected by this issue the server must be operating in a virtualized environment. and have a guest OS utilizing 32-bit PAE Paging Mode. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.0 234 .www2.0 Release Notes C02838375 available at the following link: http://h20000. This issue does not impact any processors that are not listed above.I29 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL2x220c G7 System ROM .HP Service Pack for ProLiant 2014.06. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. general protection faults. this System ROM upgrade is considered a critical fix.com/bizsupport/TechSupport/Document. have Intel Hyperthreading enabled. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. HP | Service Pack for ProLiant 2014.hp.06. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. or machine check exceptions or other unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. Addressed an issue with the Intel Xeon Processor X5675. Intel Xeon Processor X5690. While all processors supported by this server have this issue. to be affected by this issue the server must be operating in a virtualized environment. and IRQ Balancing enabled in the Operating System. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.com/bizsupport/TechSupport/Document. receive spurious interrupts or cause a network HP | Service Pack for ProLiant 2014. general protection faults. such as Linux RedHat 6.www2.0 235 .06. and have a guest OS utilizing 32-bit PAE Paging Mode. this System ROM upgrade is considered a critical fix. receive spurious interrupts or cause a network disconnect. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This issue does not impact any processors that are not listed above.hp. software may lose interrupts.0 Release Notes Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.2. such as Linux RedHat 6. or machine check exceptions or other unpredictable system behavior. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.2. and IRQ Balancing enabled in the Operating System.06. While all processors supported by this server have this issue. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. As a result of this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.HP Service Pack for ProLiant 2014. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. software may lose interrupts. Intel Xeon Processor X5690.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. have Intel Hyperthreading enabled. As a result of this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue with the Intel Xeon Processor X5675. 10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL420c Gen8 System ROM . Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2400 v2 series processors than was necessary.HP Service Pack for ProLiant 2014.0 236 . This change does not impact servers configured with Intel Xeon E5-2400 series processors.02. Improved the power allocation logic for servers configured with Intel Xeon E5-2400 v2 series processors to more accurately determine the server's maximum power usage.06. the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations.0 Release Notes disconnect. With this revision of the System ROM. Known Issues: None Online ROM Flash Component for Windows .HP ProLiant BL420c Gen8 (I30) Servers Version: 2014.06.I30 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). HP | Service Pack for ProLiant 2014. the NIC will not PXE boot or be identified or used by the operating system. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).x on Intel Xeon E5-2400 series v2 processors.HP Service Pack for ProLiant 2014. When the issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors.0 . This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. This revision of HP | Service Pack for ProLiant 2014. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.0 Release Notes Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: 237 Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Instead. When this issue occurs.06. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This issue does not impact servers configured with Intel Xeon E5-2400 series processors.x on Intel Xeon E5-2400 series v2 processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the server might experience a Non-System Disk Error or not boot the intended media. Improved the power allocation logic for servers configured with Intel Xeon E5-2400 v2 series processors to more accurately determine the server's maximum power usage.HP Service Pack for ProLiant 2014. When this issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This change does not impact servers configured with Intel Xeon E5-2400 series processors. When this issue occurs. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the NIC will not PXE boot or be identified or used by the operating system. the server might experience a Non-System Disk Error or not boot the intended media.0 .06. the System ROM revision cannot be downgraded with the flash components available on HP | Service Pack for ProLiant 2014. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).HP ProLiant BL460c (I15) Servers Version: 2011. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. With this revision of the System ROM. When the issue occurs.02 (Critical) Important Note! 238 Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.05. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Online ROM Flash Component for Windows . the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. Instead.06.0 Release Notes the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2400 v2 series processors than was necessary. com/bizsupport/TechSupport/Document.0 239 . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. Known Issues: None HP | Service Pack for ProLiant 2014. This is normally seen as the system hanging during system boot without anything displayed to video.0 Release Notes the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL460c System ROM . Once the system gets into this state.06.www2.HP Service Pack for ProLiant 2014.www2.hp.hp. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.I15 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.06.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. www2.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.hp.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows .HP Service Pack for ProLiant 2014.02 (Critical) 240 Important Note! Important Notes: HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.0 .06.0 Release Notes Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.05.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.HP ProLiant BL460c G5 (I23) Servers Version: 2011. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This is normally seen as the system hanging during system boot without anything displayed to video. Once the system gets into this state. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL460c G5 System ROM . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This is normally seen as the system hanging during system boot without anything displayed to video.I23 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.www2.06.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. HP | Service Pack for ProLiant 2014.0 Release Notes As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2.HP Service Pack for ProLiant 2014.hp.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. Once the system gets into this state.0 241 .06. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06.com/bizsupport/TechSupport/Document. This is normally seen as the system hanging during system boot without anything displayed to video.www2. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.com/bizsupport/TechSupport/Document. Once the system gets into this state.06. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014.hp.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.10.0 Release Notes Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.01 (Optional) HP | Service Pack for ProLiant 2014.hp.HP ProLiant BL460c G6/WS460c G6 (I24) Servers Version: 2013.0 242 . Known Issues: 243 None Fixes HP | Service Pack for ProLiant 2014.www2.hp.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL460c G6 and WS460c G6 System ROM . Addressed an issue where Wake On LAN would not function properly with certain Networking devices. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.I24 Release Date: 10/01/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 07/02/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed an issue where the system may experience a Blue Screen when booting Microsoft Windows 2003 with the 07/02/2013 revision of the System ROM.com/bizsupport/TechSupport/Document.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 . This issue only occurs with the 07/02/2013 revision of the System ROM and does not affect any previous revisions.0 Release Notes Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP Service Pack for ProLiant 2014.06. www2.hp.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed an issue where the system may experience a Blue Screen when booting Microsoft Windows 2003 with the 07/02/2013 revision of the System ROM.HP ProLiant BL460c G7 (I27) Servers Version: 2013.HP Service Pack for ProLiant 2014. Known Issues: None Online ROM Flash Component for Windows . This issue only occurs with the 07/02/2013 revision of the System ROM and does not affect any previous revisions.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Addressed an issue where Wake On LAN would not function properly with certain Networking devices.I27 Release Date: HP | Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.07.com/bizsupport/TechSupport/Document.com/bizsupport/TechSupport/Document.0 Release Notes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: 244 HP ProLiant BL460c G7 System ROM .0 . and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. or machine check exceptions or other unpredictable system behavior. general protection faults. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. such as Linux RedHat 6. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.06. software may lose interrupts. to be affected by this issue the server must be operating in a virtualized environment. While all processors supported by this server have this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. Intel Xeon Processor X5690. and have a guest OS utilizing 32-bit PAE Paging Mode.0 .06. As a result of this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.2. and IRQ Balancing enabled in the Operating System.HP Service Pack for ProLiant 2014. this System ROM upgrade is considered a critical fix. This issue does not impact any processors that are not listed above. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Known Issues: 245 None Fixes HP | Service Pack for ProLiant 2014. Addressed an issue with the Intel Xeon Processor X5675. receive spurious interrupts or cause a network disconnect. have Intel Hyperthreading enabled. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.0 Release Notes 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/03/2012 Firmware Dependencies: None Enhancements/New Features: None. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. HP Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. software may lose interrupts. and IRQ Balancing enabled in the Operating System. Intel Xeon Processor X5690. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. Known Issues: None Online ROM Flash Component for Windows .06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. such as Linux RedHat 6. Due to the potential severity of the issue addressed in this revision of the System ROM. While all processors supported by this server have this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. have Intel Hyperthreading enabled.www2.0 Release Notes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This issue does not impact any processors that are not listed above. As a result of this issue. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. this System ROM upgrade is considered a critical fix. or machine check exceptions or other unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.02. receive spurious interrupts or cause a network disconnect. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. to be affected by this issue the server must be operating in a virtualized environment. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.HP ProLiant BL460c/WS460c Gen8 (I31) Servers Version: 2014.10 (Optional) HP | Service Pack for ProLiant 2014.06.com/bizsupport/TechSupport/Document. and have a guest OS utilizing 32-bit PAE Paging Mode. Addressed an issue with the Intel Xeon Processor X5675.0 246 . general protection faults.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.2.hp. When this issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This change does not impact servers configured with Intel Xeon E5-2600 series processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014.06.x on Intel Xeon E5-2600 series v2 processors. the server might experience a Non-System Disk Error or not HP | Service Pack for ProLiant 2014. Improved the power allocation logic for servers configured with Intel Xeon E5-2600 v2 series processors to more accurately determine the server's maximum power usage.I31 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2600 v2 series processors than was necessary. the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations.0 247 . Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06. With this revision of the System ROM.0 Release Notes Important Note! Important Notes: None Deliverable Name: HP ProLiant BL460c/WS460c Gen8 System ROM . This issue does not impact servers configured with Intel Xeon E5-2600 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). When this issue occurs.06.0 248 . Instead. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When this issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.0 Release Notes boot the intended media.06. When the issue occurs. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.HP Service Pack for ProLiant 2014.x on Intel Xeon E5-2600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. When this issue occurs. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. the server will indicate an early boot progress of 20% and a "Memory and HP | Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. the NIC will not PXE boot or be identified or used by the operating system. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. HP Service Pack for ProLiant 2014. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This change does not impact servers configured with Intel Xeon E5-2600 series processors.www2.hp. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-2600 v2 series processors than was necessary.com/bizsupport/TechSupport/Document. When the issue occurs.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Instead. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.A13 Release Date: HP | Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: 249 HP ProLiant BL465c G1/G5/G6 System ROM . the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations.05.0 Release Notes QPI Link Initialization Start" message will be displayed on the screen output.06. With this revision of the System ROM. Online ROM Flash Component for Windows . the NIC will not PXE boot or be identified or used by the operating system. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Improved the power allocation logic for servers configured with Intel Xeon E5-2600 v2 series processors to more accurately determine the server's maximum power usage.HP ProLiant BL465c G1/BL465c G5/BL465c G6 (A13) Servers Version: 2011. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 . www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.0 250 . Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 Release Notes 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 12/08/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None HP | Service Pack for ProLiant 2014.hp.06. 0 Release Notes Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).HP ProLiant BL465c G7 (A19) Servers Version: 2014.jsp?locale=en_US&objectID=c028 38375 Online ROM Flash Component for Windows . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.HP Service Pack for ProLiant 2014.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 .hp.com/bizsupport/TechSupport/Document.A19 Release Date: 02/02/2014 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 251 12/08/2012 Firmware Dependencies: HP | Service Pack for ProLiant 2014. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06.02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL465c G7 System ROM . Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.02.www2. HP ProLiant BL465c Gen8 (A26) Servers Version: 2014.0 . Known Issues: None Online ROM Flash Component for Windows .06.0 Release Notes None Enhancements/New Features: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.HP Service Pack for ProLiant 2014.06.06 (Optional) Important Note! Important Notes: None Deliverable Name: 252 HP ProLiant BL465c Gen8 System ROM .02.A26 HP | Service Pack for ProLiant 2014. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.HP Service Pack for ProLiant 2014.0 Release Notes Release Date: 02/06/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 11/02/2013 Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).06. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision.06. the server might experience a Non-System Disk Error or not boot the intended media. When this issue occurs. Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters. Known Issues: None Fixes Important Notes: None 253 Firmware Dependencies: None HP | Service Pack for ProLiant 2014. This issue did not impact any other revisions of the System ROM. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.0 . HP ProLiant BL480c (I14) Server Version: 2011.www2. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active.hp.0 Release Notes Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL480c G1 System ROM . The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.0 .06.com/bizsupport/TechSupport/Document. Known Issues: None Enhancements Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP Service Pack for ProLiant 2014.05. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision.06. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. the server might experience a Non-System Disk Error or not boot the intended media. This issue did not impact any other revisions of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Online ROM Flash Component for Windows .I14 Release Date: 254 05/02/2011 HP | Service Pack for ProLiant 2014. When this issue occurs. 0 255 .www2.0 Release Notes Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This is normally seen as the system hanging during system boot without anything displayed to video.06.HP Service Pack for ProLiant 2014. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.06. Once the system gets into this state.com/bizsupport/TechSupport/Document.com/bizsupport/TechSupport/Document.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. 06. Once the system gets into this state.hp.0 Release Notes Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.07.com/bizsupport/TechSupport/Document. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.www2.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 256 Deliverable Name: HP ProLiant BL490 G6 System ROM . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.0 .com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.HP Service Pack for ProLiant 2014.hp. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.I21 HP | Service Pack for ProLiant 2014.www2. This is normally seen as the system hanging during system boot without anything displayed to video.06.HP ProLiant BL490c G6 (I21) Servers Version: 2013. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. this System ROM upgrade is considered a critical fix. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. receive spurious interrupts or cause a network disconnect.06. Addressed an issue with the Intel Xeon Processor X5675.2. Intel Xeon Processor X5690. As a result of this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.HP Service Pack for ProLiant 2014. 257 Known Issues: None HP | Service Pack for ProLiant 2014. and IRQ Balancing enabled in the Operating System. Due to the potential severity of the issue addressed in this revision of the System ROM.0 . This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. general protection faults. to be affected by this issue the server must be operating in a virtualized environment. such as Linux RedHat 6. and have a guest OS utilizing 32-bit PAE Paging Mode. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. or machine check exceptions or other unpredictable system behavior. have Intel Hyperthreading enabled.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. While all processors supported by this server have this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. software may lose interrupts. This issue does not impact any processors that are not listed above. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.0 Release Notes Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 05/05/2011 Firmware Dependencies: None Enhancements/New Features: None. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Intel Xeon Processor X5690. software may lose interrupts.06.06. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. As a result of this issue. have Intel Hyperthreading enabled.HP Service Pack for ProLiant 2014. Known Issues: None 258 HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.www2. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. Addressed an issue with the Intel Xeon Processor X5675. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and IRQ Balancing enabled in the Operating System.0 . to be affected by this issue the server must be operating in a virtualized environment. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 Release Notes Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. such as Linux RedHat 6. Due to the potential severity of the issue addressed in this revision of the System ROM. This issue does not impact any processors that are not listed above. this System ROM upgrade is considered a critical fix. receive spurious interrupts or cause a network disconnect. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. While all processors supported by this server have this issue.hp. and have a guest OS utilizing 32-bit PAE Paging Mode. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. or machine check exceptions or other unpredictable system behavior.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. general protection faults.2. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. While all processors supported by this server have this issue.06.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This issue is not unique to HP ProLiant servers and HP | Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 Release Notes Online ROM Flash Component for Windows . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL490c G7 System ROM .www2.hp. have Intel Hyperthreading enabled.0 259 . or machine check exceptions or other unpredictable system behavior. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.I28 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/03/2012 Firmware Dependencies: None Enhancements/New Features: None.06.07. and have a guest OS utilizing 32-bit PAE Paging Mode. general protection faults.HP ProLiant BL490c G7 (I28) Servers Version: 2013.HP Service Pack for ProLiant 2014. to be affected by this issue the server must be operating in a virtualized environment.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.2. general protection faults. to be affected by this issue the server must be operating in a virtualized environment. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. As a result of this issue.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. software may lose interrupts. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and have a guest OS utilizing 32-bit PAE Paging Mode. such as Linux RedHat 6. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.hp.HP Service Pack for ProLiant 2014. While all processors supported by this server have this issue. this System ROM upgrade is considered a critical fix.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.0 Release Notes could impact any system utilizing affected processors operating with the conditions listed above. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This issue does not impact any processors that are not listed above.0 260 . Due to the potential severity of the issue addressed in this revision of the System ROM. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.06. receive spurious interrupts or cause a network disconnect.com/bizsupport/TechSupport/Document. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Due to the potential severity of the issue addressed in this revision of the System ROM. or machine check exceptions or other unpredictable system behavior. Intel Xeon Processor X5690. HP | Service Pack for ProLiant 2014.www2. and IRQ Balancing enabled in the Operating System. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. have Intel Hyperthreading enabled. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. this System ROM upgrade is considered a critical fix. Addressed an issue with the Intel Xeon Processor X5675. hp.www2.HP ProLiant BL495c G5/BL495c G6 (A14) Servers Version: 2011.HP Service Pack for ProLiant 2014. such as Linux RedHat 6.06.A14 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 261 Previous Revision: HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL495c G5/G6 System ROM . This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Intel Xeon Processor X5690. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. Known Issues: None Online ROM Flash Component for Windows . This issue does not impact any processors that are not listed above.0 . As a result of this issue. software may lose interrupts. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. receive spurious interrupts or cause a network disconnect.05.2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. and IRQ Balancing enabled in the Operating System. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.06. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.0 Release Notes Addressed an issue with the Intel Xeon Processor X5675. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.06.06.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.www2. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Problems Fixed: Resolved an issue where the system may not be able to install an operating system to an iSCSI-based storage solution when using the local DVD drive.0 .jsp?locale=en_US&objectID=c0283837 5 Added latest product names for display in the ROM-Based Setup Utility (RBSU).hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp. HP | Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: 262 Resolved an issue where the system may not be able to install an operating system to an iSCSI-based storage solution when using the local DVD drive.0 Release Notes 12/09/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. 02.com/bizsupport/TechSupport/Document.I32 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 263 Firmware Dependencies: None HP | Service Pack for ProLiant 2014.hp.www2. Online ROM Flash Component for Windows .HP ProLiant BL660c Gen8 (I32) Servers Version: 2014.0 .0 Release Notes Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Added latest product names for display in the ROM-Based Setup Utility (RBSU). Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06.HP Service Pack for ProLiant 2014.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL660c Gen8 System ROM . Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.HP Service Pack for ProLiant 2014. When this issue occurs. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Known Issues: None HP | Service Pack for ProLiant 2014.0 264 . With this revision of the System ROM. Improved the power allocation logic for servers configured with Intel Xeon E5-4600 v2 series processors to more accurately determine the server's maximum power usage. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting). Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This issue was originally seen with servers configured with Microsoft Windows Server 2012. but might impact other operating systems. the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations. This change does not impact servers configured with Intel Xeon E5-4600 series processors. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors. When the issue occurs.06.x on Intel Xeon E5-4600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the server might experience a Non-System Disk Error or not boot the intended media. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does not impact servers configured with Intel Xeon E5-4600 series processors. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-4600 v2 series processors than was necessary.0 Release Notes Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the NIC will not PXE boot or be identified or used by the operating system. Instead. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. When this issue occurs.06. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors. the server might experience a Non-System Disk Error or not boot the intended media. 265 Known Issues: None HP | Service Pack for ProLiant 2014. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.HP Service Pack for ProLiant 2014. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. This issue does not impact servers configured with Intel Xeon E5-4600 series processors. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.x on Intel Xeon E5-4600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.0 . but might impact other operating systems. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). When the issue occurs. the NIC will not PXE boot or be identified or used by the operating system. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Instead.0 Release Notes Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue was originally seen with servers configured with Microsoft Windows Server 2012. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When this issue occurs.06. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting). the enclosure may have additional power available to allow additional blades to be powered on with certain power supply configurations.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 Release Notes Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). With this revision of the System ROM.05.I17 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None 266 Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and HP | Service Pack for ProLiant 2014.06.HP ProLiant BL680c G5 (I17) Servers Version: 2011. Improved the power allocation logic for servers configured with Intel Xeon E5-4600 v2 series processors to more accurately determine the server's maximum power usage.www2. This change does not impact servers configured with Intel Xeon E5-4600 series processors.com/bizsupport/TechSupport/Document.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant BL680c G5 System ROM . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.0 .hp. Previous revisions of the System ROM allocated more power for server blades configured with Intel Xeon E5-4600 v2 series processors than was necessary. Online ROM Flash Component for Windows . hp. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.0 267 .jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved an issue where the system may hang when trying to apply custom settings using the ROM Based Setup Utility (RBSU) User Defined Defaults Option. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved an issue where the system may hang when trying to apply custom settings using the ROM Based Setup Utility (RBSU) User Defined Defaults Option.com/bizsupport/TechSupport/Document.www2.06.com/bizsupport/TechSupport/Document. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 Release Notes decrease the probability of unintended corruption of the flash part.HP Service Pack for ProLiant 2014.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: HP | Service Pack for ProLiant 2014.06. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows .HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. or machine check exceptions or other unpredictable system behavior.01 (Critical) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL620c/BL680c G7 System ROM .06.I25 Release Date: 07/01/2013 Last Recommended or Critical Revision: 07/01/2013 Previous Revision: 04/01/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.0 Release Notes http://h20000. While all processors supported by this server have this issue.07. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.hp. and have a guest OS utilizing 32-bit PAE Paging Mode.HP ProLiant BL680c G7/BL620c G7 (I25) Servers Version: 2013. to be affected by this issue the server must be operating in a virtualized environment.www2. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. general protection faults. have Intel Hyperthreading enabled.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. HP | Service Pack for ProLiant 2014.0 268 . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. general protection faults. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. and have a guest OS utilizing 32-bit PAE Paging Mode.05. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. this System ROM upgrade is considered a critical fix.HP ProLiant BL685c G1/BL685c G5 (A08) Servers Version: 2011.com/bizsupport/TechSupport/Document.06. Known Issues: None Online ROM Flash Component for Windows .HP Service Pack for ProLiant 2014.0 269 . have Intel Hyperthreading enabled. to be affected by this issue the server must be operating in a virtualized environment.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 HP | Service Pack for ProLiant 2014. While all processors supported by this server have this issue.0 Release Notes Due to the potential severity of the issue addressed in this revision of the System ROM.www2. Due to the potential severity of the issue addressed in this revision of the System ROM. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.hp. this System ROM upgrade is considered a critical fix. or machine check exceptions or other unpredictable system behavior. com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in HP | Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 270 .www2.A08 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 12/14/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 Release Notes 5 Deliverable Name: HP ProLiant BL685c G1/G5 System ROM . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014.06. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Added latest product names for display in the ROM-Based Setup Utility (RBSU).hp. hp.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Added latest product names for display in the ROM-Based Setup Utility (RBSU).06.0 .hp.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: 271 HP ProLiant BL685c G6 System ROM . Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.A17 Release Date: HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014.www2.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows .06.HP ProLiant BL685c G6 (A17) Servers Version: 2011.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.05.com/bizsupport/TechSupport/Document.www2.0 Release Notes Advisory C02838375 available at the following link: http://h20000. com/bizsupport/TechSupport/Document.06.com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.jsp?locale=en_US&objectID=c0283837 5 Added latest product names for display in the ROM-Based Setup Utility (RBSU).www2. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 272 .0 Release Notes 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 12/09/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.hp.www2.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Problems Fixed: Resolved an issue where the system may not be able to install an operating system to an iSCSI-based storage solution when using the local DVD drive. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. www2.com/bizsupport/TechSupport/Document. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.0 .0 Release Notes Firmware Dependencies: None Problems Fixed: Resolved an issue where the system may not be able to install an operating system to an iSCSI-based storage solution when using the local DVD drive. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Online ROM Flash Component for Windows .jsp?locale=en_US&objectID=c0283837 5 Added latest product names for display in the ROM-Based Setup Utility (RBSU). Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06.HP Service Pack for ProLiant 2014.HP ProLiant BL685c G7 (A20) Servers Version: 2014.01 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant BL685c G7 System ROM Release Date: 02/01/2014 273 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.02. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. Known Issues: None 274 HP | Service Pack for ProLiant 2014.0 .06.0 Release Notes 12/17/2012 Previous Revision: 06/04/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.06. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. This issue did not impact any other revisions of the System ROM.HP Service Pack for ProLiant 2014. This issue did not impact any other revisions of the System ROM. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.HP Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL160 Gen8 System ROM . This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.x on Intel Xeon E5-2600 series v2 processors.HP ProLiant DL160 Gen8 (J03) Servers Version: 2014. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 275 .J03 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None.0 Release Notes Online ROM Flash Component for Windows . HP | Service Pack for ProLiant 2014.06.02. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014.06. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.06. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.x on Intel Xeon E5-2600 series v2 processors. When this issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.0 276 . This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. When the issue occurs. HP | Service Pack for ProLiant 2014. Instead. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the NIC will not PXE boot or be identified or used by the operating system. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does not impact servers configured with Intel Xeon E5-2600 series processors.0 Release Notes Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs. HP Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.07.06.hp. Online ROM Flash Component for Windows .0 Release Notes Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This revision of the System ROM is required for proper operation of the embedded SATA solution when a Generation 2 (3.06.0 Gb/s) SATA Hard Drives. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.W07 Release Date: HP | Service Pack for ProLiant 2014. When the issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). the NIC will not PXE boot or be identified or used by the operating system. Instead. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 Gb/s) SATA hard drive is installed in the server (DL320 G5 only).0 . Online ROM Flash Component for Windows .10 (Optional) Enhancements Added support for Generation 2 (3.HP ProLiant DL320 G5/DL320s (W04) Servers Version: 2008.06.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: 277 HP ProLiant ML330 G6 and DL320 G6 System ROM . Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.HP ProLiant DL320 G6/ML330 G6 (W07) Servers Version: 2013. 0 . to be affected by this issue the server must be operating in a virtualized environment. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. and IRQ Balancing enabled in the Operating System.06. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. software may lose interrupts. such as Linux RedHat 6. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Known Issues: 278 None Fixes HP | Service Pack for ProLiant 2014. While all processors supported by this server have this issue.2. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. general protection faults. Addressed an issue with the Intel Xeon Processor X5675. Due to the potential severity of the issue addressed in this revision of the System ROM. receive spurious interrupts or cause a network disconnect. As a result of this issue. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does not impact any processors that are not listed above. Intel Xeon Processor X5690. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. have Intel Hyperthreading enabled. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. or machine check exceptions or other unpredictable system behavior. and have a guest OS utilizing 32-bit PAE Paging Mode. this System ROM upgrade is considered a critical fix.06.HP Service Pack for ProLiant 2014.0 Release Notes 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. software may lose interrupts. Addressed an issue with the Intel Xeon Processor X5675. Intel Xeon Processor X5690. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Due to the potential severity of the issue addressed in this revision of the System ROM.com/bizsupport/TechSupport/Document.0 279 . have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 Release Notes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. have Intel Hyperthreading enabled. As a result of this issue.2. general protection faults.HP Service Pack for ProLiant 2014. Known Issues: None Online ROM Flash Component for Windows . and have a guest OS utilizing 32-bit PAE Paging Mode. this System ROM upgrade is considered a critical fix. While all processors supported by this server have this issue.06. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.HP ProLiant DL320e Gen8 (J05) Servers Version: 2013. or machine check exceptions or other unpredictable system behavior.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.09 (Optional) HP | Service Pack for ProLiant 2014. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.11. to be affected by this issue the server must be operating in a virtualized environment. This issue does not impact any processors that are not listed above.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.hp. such as Linux RedHat 6. receive spurious interrupts or cause a network disconnect. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2. and IRQ Balancing enabled in the Operating System. Previously. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). For these new selections to function. Problems Fixed: 280 None Known Issues: HP | Service Pack for ProLiant 2014.06. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. the system must be using Integrated Lights-Out (iLO) Firmware version 1. 30. This allows the System ROM to attempt to boot the next device in the boot order.HP Service Pack for ProLiant 2014. If the system is configured to one of the new options without having iLO Firmware version 1. the Power-On Delay Option will function as if the No Delay option were chosen.J05 Release Date: 11/09/2013 Last Recommended or Critical Revision: 08/24/2013 Previous Revision: 08/24/2013 Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay).0 Release Notes Important Note! Important Notes: None Deliverable Name: HP ProLiant DL320e Gen8 System ROM .20 or later.06.0 . In some cases.20 or later. This allows the System ROM to attempt to boot the next device in the boot order.0 Release Notes None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. the system must be using Integrated Lights-Out (iLO) Firmware version 1. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. the Power-On Delay Option will function as if the No Delay option were chosen.06. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. For these new selections to function.28 (Optional) Important Note! Important Notes: None Deliverable Name: 281 HP ProLiant DL320e Gen8 v2 System ROM .HP Service Pack for ProLiant 2014.0 . 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay).03. If the system is configured to one of the new options without having iLO Firmware version 1. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).20 or later. 30.06. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives.20 or later.HP ProLiant DL320e Gen8 v2 (P80) Servers Version: 2014. Previously.P80 HP | Service Pack for ProLiant 2014. Known Issues: None Online ROM Flash Component for Windows . In some cases. HP Service Pack for ProLiant 2014. This problem only affects servers with the 03/07/2014 revision of the System ROM.06. This issue has no known impact with TPM functionality under normal operating system environments.0 282 . This issue has no known impact with TPM functionality under normal operating system environments.06.0 Release Notes Release Date: 03/28/2014 Last Recommended or Critical Revision: 03/07/2014 Previous Revision: 03/07/2014 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed an issue where servers using the 03/07/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test. This problem only affects servers with the 03/07/2014 revision of the System ROM. HP | Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where servers using the 03/07/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test. 0 283 .05.0 Release Notes Known Issues: None Online ROM Flash Component for Windows . A customer can downgrade the System ROM by creating a new flash HP | Service Pack for ProLiant 2014.HP ProLiant DL360 G5 (P58) Servers Version: 2011. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.P58 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL360 G5 System ROM .06.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.hp.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.0 . the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. Known Issues: None 284 Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.www2.06.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. the System ROM HP | Service Pack for ProLiant 2014.hp. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.06.HP Service Pack for ProLiant 2014. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This is normally seen as the system hanging during system boot without anything displayed to video.0 Release Notes component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.www2. Once the system gets into this state. This is normally seen as the system hanging during system boot without anything displayed to video. Once the system gets into this state. jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL360 G6 System ROM .06.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows .06.hp.07.0 . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.P64 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 05/05/2011 Firmware Dependencies: None Enhancements/New Features: 285 None HP | Service Pack for ProLiant 2014.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP ProLiant DL360 G6 (P64) Servers Version: 2013. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 Release Notes revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2.www2.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. receive spurious interrupts or cause a network disconnect.0 Release Notes Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.www2.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None 286 Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor HP | Service Pack for ProLiant 2014. This issue does not impact any processors that are not listed above. have Intel Hyperthreading enabled. and have a guest OS utilizing 32-bit PAE Paging Mode. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.com/bizsupport/TechSupport/Document. general protection faults.HP Service Pack for ProLiant 2014.06. Intel Xeon Processor X5690. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Due to the potential severity of the issue addressed in this revision of the System ROM.2. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. While all processors supported by this server have this issue.0 . such as Linux RedHat 6. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.06. this System ROM upgrade is considered a critical fix. or machine check exceptions or other unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. As a result of this issue. and IRQ Balancing enabled in the Operating System.hp. to be affected by this issue the server must be operating in a virtualized environment. software may lose interrupts. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Addressed an issue with the Intel Xeon Processor X5675. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Known Issues: None Online ROM Flash Component for Windows . Intel Xeon Processor X5690.07. This issue does not impact any processors that are not listed above.com/bizsupport/TechSupport/Document.hp.0 .P68 HP | Service Pack for ProLiant 2014. general protection faults.www2. Addressed an issue with the Intel Xeon Processor X5675. to be affected by this issue the server must be operating in a virtualized environment. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. have Intel Hyperthreading enabled.0 Release Notes microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: 287 HP ProLiant DL360 G7 System ROM . This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. or machine check exceptions or other unpredictable system behavior. such as Linux RedHat 6. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. As a result of this issue.2. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. and have a guest OS utilizing 32-bit PAE Paging Mode.HP Service Pack for ProLiant 2014. this System ROM upgrade is considered a critical fix. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. While all processors supported by this server have this issue.HP ProLiant DL360 G7 (P68) Servers Version: 2013. and IRQ Balancing enabled in the Operating System. software may lose interrupts. Due to the potential severity of the issue addressed in this revision of the System ROM.06. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. receive spurious interrupts or cause a network disconnect. to be affected by this issue the server must be operating in a virtualized environment. Intel Xeon Processor X5690.06. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. software may lose interrupts. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Due to the potential severity of the issue addressed in this revision of the System ROM. Addressed an issue with the Intel Xeon Processor X5675. As a result of this issue.0 . this System ROM upgrade is considered a critical fix.2. general protection faults. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. have Intel Hyperthreading enabled.06. While all processors supported by this server have this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This issue does not impact any processors that are not listed above. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. receive spurious interrupts or cause a network disconnect. such as Linux RedHat 6.HP Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. or machine check exceptions or other unpredictable system behavior. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and IRQ Balancing enabled in the Operating System. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.0 Release Notes Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. 288 Known Issues: None HP | Service Pack for ProLiant 2014. and have a guest OS utilizing 32-bit PAE Paging Mode. and have a guest OS utilizing 32-bit PAE Paging Mode.hp. Due to the potential severity of the issue addressed in this revision of the System ROM. As a result of this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Known Issues: None 289 HP | Service Pack for ProLiant 2014.0 Release Notes Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. While all processors supported by this server have this issue. and IRQ Balancing enabled in the Operating System. or machine check exceptions or other unpredictable system behavior. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. such as Linux RedHat 6. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.HP Service Pack for ProLiant 2014.0 . Addressed an issue with the Intel Xeon Processor X5675. this System ROM upgrade is considered a critical fix.06.2. have Intel Hyperthreading enabled. This issue does not impact any processors that are not listed above. general protection faults. to be affected by this issue the server must be operating in a virtualized environment. software may lose interrupts.06. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. Intel Xeon Processor X5690. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.www2. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. receive spurious interrupts or cause a network disconnect.com/bizsupport/TechSupport/Document. 10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL360e/DL380e Gen8 System ROM .0 Release Notes Online ROM Flash Component for Windows .HP Service Pack for ProLiant 2014.P73 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).x on Intel Xeon E5-2400 series v2 processors. HP | Service Pack for ProLiant 2014. When this issue occurs. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. the server might experience a Non-System Disk Error or not boot the intended media.HP ProLiant DL360e Gen8/DL380e Gen8 (P73) Servers Version: 2014.06. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors.06.02. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.0 290 . Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. When this issue occurs.06. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.0 Release Notes Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the NIC will not PXE boot or be identified or used by the operating system. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.HP Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When the issue occurs. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 291 . the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. When this issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the server might experience a Non-System Disk Error or not boot the intended media.x on Intel Xeon E5-2400 series v2 processors.06. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Instead. HP | Service Pack for ProLiant 2014. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When the issue occurs.P71 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: 292 None.06. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.06. HP | Service Pack for ProLiant 2014. the NIC will not PXE boot or be identified or used by the operating system.0 .HP Service Pack for ProLiant 2014.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL360p Gen8/DL360p Gen8 SE System ROM . Instead.HP ProLiant DL360p Gen8/DL360p Gen8 SE (P71) Servers Version: 2014.02. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 Release Notes Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Online ROM Flash Component for Windows . When the issue occurs. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.x on Intel Xeon E5-2600 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. When this issue occurs. the server might experience a Non-System Disk Error or not boot the intended media.0 Release Notes Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Known Issues: None Fixes Important Notes: None 293 Firmware Dependencies: None. Instead. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. HP | Service Pack for ProLiant 2014. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.06. When this issue occurs.0 . This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the NIC will not PXE boot or be identified or used by the operating system.HP Service Pack for ProLiant 2014.06. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.06.02 (Critical) Important Note! 294 Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead.05. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.0 Release Notes Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. the server might experience a Non-System Disk Error or not boot the intended media. the System ROM revision cannot be downgraded with the flash components available on HP | Service Pack for ProLiant 2014. When this issue occurs. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs.HP Service Pack for ProLiant 2014. Online ROM Flash Component for Windows . the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). When the issue occurs. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the NIC will not PXE boot or be identified or used by the operating system.x on Intel Xeon E5-2600 series v2 processors.0 .HP ProLiant DL365 G1/DL365 G5 (A10) Servers Version: 2011. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. A10 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 07/17/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.0 .com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2.06.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL365 G1/G5 System ROM .com/bizsupport/TechSupport/Document.hp.hp.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU). A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2. Known Issues: None 295 Fixes HP | Service Pack for ProLiant 2014.0 Release Notes the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. hp.HP ProLiant DL380 G5 (P56) Servers Version: 2011. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 HP | Service Pack for ProLiant 2014.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2.0 296 .05. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.0 Release Notes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU). the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.www2.06.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows .hp.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.hp. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. This is normally seen as the system hanging during system boot without anything displayed to video. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.HP Service Pack for ProLiant 2014.06.P56 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.hp.com/bizsupport/TechSupport/Document.www2.0 Release Notes 5 Deliverable Name: HP ProLiant DL380 G5 System ROM . Once the system gets into this state. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Known Issues: None 297 Fixes HP | Service Pack for ProLiant 2014.0 . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 Release Notes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.HP ProLiant DL380 G6 (P62) Servers Version: 2013.07.com/bizsupport/TechSupport/Document. Once the system gets into this state. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.com/bizsupport/TechSupport/Document.hp.hp. the System ROM revision cannot be downgraded with the flash components available on the HP HP | Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.02 (Critical) Important Note! 298 Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 .06.06.HP Service Pack for ProLiant 2014. This is normally seen as the system hanging during system boot without anything displayed to video.www2. general protection faults. and have a guest OS utilizing 32-bit PAE Paging Mode. Addressed an issue with the Intel Xeon Processor X5675.0 299 . and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.com/bizsupport/TechSupport/Document. have Intel Hyperthreading enabled.0 Release Notes Support site after updating to this revision of the System ROM.www2. Due to the potential severity of the issue addressed in this revision of the System ROM. HP | Service Pack for ProLiant 2014. this System ROM upgrade is considered a critical fix.HP Service Pack for ProLiant 2014. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.hp.P62 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 05/05/2011 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Intel Xeon Processor X5690. or machine check exceptions or other unpredictable system behavior. While all processors supported by this server have this issue.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL380 G6 System ROM . to be affected by this issue the server must be operating in a virtualized environment.06. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. or machine check exceptions or other unpredictable system behavior. general protection faults.2. and have a guest OS utilizing 32-bit PAE Paging Mode. and IRQ Balancing enabled in the Operating System. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP Service Pack for ProLiant 2014.www2. such as Linux RedHat 6. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. software may lose interrupts.com/bizsupport/TechSupport/Document.0 300 . Addressed an issue with the Intel Xeon Processor X5675. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. such as Linux RedHat 6. Intel Xeon Processor X5690. and IRQ Balancing enabled in the Operating System.0 Release Notes This issue does not impact any processors that are not listed above. receive spurious interrupts or cause a network disconnect. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. to be affected by this issue the server must be operating in a virtualized environment. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. This issue does not impact any processors that are not listed above. As a HP | Service Pack for ProLiant 2014.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. this System ROM upgrade is considered a critical fix. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.2. While all processors supported by this server have this issue. Due to the potential severity of the issue addressed in this revision of the System ROM. As a result of this issue. have Intel Hyperthreading enabled.hp.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. P67 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: 301 None. software may lose interrupts.06.HP Service Pack for ProLiant 2014.07. HP | Service Pack for ProLiant 2014.0 Release Notes result of this issue.www2.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06.hp.HP ProLiant DL380 G7 (P67) Servers Version: 2013. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Known Issues: None Online ROM Flash Component for Windows . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 .com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL380 G7 System ROM . receive spurious interrupts or cause a network disconnect. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None 302 Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor HP | Service Pack for ProLiant 2014. general protection faults. have Intel Hyperthreading enabled. software may lose interrupts.hp. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. receive spurious interrupts or cause a network disconnect. and have a guest OS utilizing 32-bit PAE Paging Mode. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. and IRQ Balancing enabled in the Operating System. this System ROM upgrade is considered a critical fix. This issue does not impact any processors that are not listed above.www2.HP Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 . While all processors supported by this server have this issue. Intel Xeon Processor X5690. As a result of this issue. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.2. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.06. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.06. Due to the potential severity of the issue addressed in this revision of the System ROM. to be affected by this issue the server must be operating in a virtualized environment. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue with the Intel Xeon Processor X5675.com/bizsupport/TechSupport/Document.0 Release Notes Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. such as Linux RedHat 6. or machine check exceptions or other unpredictable system behavior. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. 10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL380p Gen8 System ROM . such as Linux RedHat 6. software may lose interrupts.HP ProLiant DL380p Gen8 (P70) Servers Version: 2014. and have a guest OS utilizing 32-bit PAE Paging Mode. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. and IRQ Balancing enabled in the Operating System. have Intel Hyperthreading enabled. As a result of this issue. Due to the potential severity of the issue addressed in this revision of the System ROM.HP Service Pack for ProLiant 2014. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. to be affected by this issue the server must be operating in a virtualized environment. Intel Xeon Processor X5690.2.06. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.02. general protection faults. this System ROM upgrade is considered a critical fix. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. receive spurious interrupts or cause a network disconnect. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. or machine check exceptions or other unpredictable system behavior.0 . While all processors supported by this server have this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Known Issues: None Online ROM Flash Component for Windows . This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 Release Notes microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Addressed an issue with the Intel Xeon Processor X5675.06. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.P70 Release Date: 02/10/2014 303 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014. This issue does not impact any processors that are not listed above. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. When this issue occurs. Known Issues: 304 None Fixes HP | Service Pack for ProLiant 2014. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.06. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the server might experience a Non-System Disk Error or not boot the intended media. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Instead.HP Service Pack for ProLiant 2014. the NIC will not PXE boot or be identified or used by the operating system.06.0 Release Notes 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None.x on Intel Xeon E5-2600 series v2 processors. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). When this issue occurs.0 . When the issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.06. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.06. When this issue occurs. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. the NIC will not PXE boot or be identified or used by the operating system.0 Release Notes Important Notes: None Firmware Dependencies: None. When this issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 . 305 HP | Service Pack for ProLiant 2014.x on Intel Xeon E5-2600 series v2 processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. When the issue occurs. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. the server might experience a Non-System Disk Error or not boot the intended media. Instead. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.HP Service Pack for ProLiant 2014. com/bizsupport/TechSupport/Document.0 306 .com/bizsupport/TechSupport/Document. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.www2.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL385 G2/G5 System ROM .HP ProLiant DL385 G2/DL385 G5 (A09) Servers Version: 2011.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.0 Release Notes Online ROM Flash Component for Windows .02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.A09 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 07/11/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.05. 06. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.02 (Critical) HP | Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 307 Online ROM Flash Component for Windows . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.06.HP ProLiant DL385 G5p/DL385 G6 (A22) Servers Version: 2011.com/bizsupport/TechSupport/Document.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).0 . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.05.www2. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 Release Notes Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU). 0 Release Notes Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: 308 Resolved an issue where the in PCI Slot number.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. as reported under the operating system. HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.www2.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL385 G5p/G6 System ROM . would not be reported correctly when a three slot PCI-E riser is installed in the platform.A22 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 02/09/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document.0 .www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp. www2.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved an issue where the in PCI Slot number. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.06.06.HP ProLiant DL385 G7 (A18) Servers Version: 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows .02. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.com/bizsupport/TechSupport/Document. as reported under the operating system. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.com/bizsupport/TechSupport/Document.0 .0 Release Notes Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. would not be reported correctly when a three slot PCI-E riser is installed in the platform.02 (Optional) 309 Important Note! Important Notes: HP | Service Pack for ProLiant 2014.www2. HP | Service Pack for ProLiant 2014.A18 Release Date: 02/02/2014 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 12/08/2012 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors.HP Service Pack for ProLiant 2014.0 Release Notes None Deliverable Name: HP ProLiant DL385 G7 System ROM .0 .06.06. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None 310 Problems Fixed: Resolved a very rare condition where the system could become unresponsive or unexpectedly reset when running with AMD Opteron 6100 or 6200 processors. 06.A28 Release Date: 02/06/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 11/02/2013 Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters.0 311 .HP ProLiant DL385p Gen8 (A28) Servers Version: 2014.HP Service Pack for ProLiant 2014. When this issue occurs. the server might experience a Non-System Disk Error or not boot the HP | Service Pack for ProLiant 2014.0 Release Notes Known Issues: None Online ROM Flash Component for Windows .06 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL385p Gen8 System ROM .02. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active.06. This issue did not impact any other revisions of the System ROM. Addressed an issue where servers using the 11/02/2013 revision of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record which is not marked as Active.0 Release Notes intended media. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values.HP Service Pack for ProLiant 2014.06.HP ProLiant DL560 Gen8 (P77) Servers Version: 2014. 312 Online ROM Flash Component for Windows . This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision. The 06/09/2013 and 11/02/2013 revisions of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. the server might experience a Non-System Disk Error or not boot the intended media. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where the System ROM would not properly retry devices in the Standard Boot Order (IPL) with certain Network Adapters.10 (Optional) HP | Service Pack for ProLiant 2014. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.06. This issue did not impact any other revisions of the System ROM. When this issue occurs. Known Issues: None Enhancements Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.0 .02. This issue does NOT impact any System ROM revisions other than the 11/02/2013 revision. HP Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 313 . This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.06. This issue was originally seen with HP | Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors.0 Release Notes Important Note! Important Notes: None Deliverable Name: HP ProLiant DL560 Gen8 System ROM .06.x on Intel Xeon E5-4600 series v2 processors.P77 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When this issue occurs. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting). 0 Release Notes servers configured with Microsoft Windows Server 2012.06. This issue impacts servers with the ROM-Based Setup Utility (RBSU) option for Collaborative Power Control enabled (which is the default setting).HP Service Pack for ProLiant 2014. This issue was originally seen with HP | Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media. but might impact other operating systems. This issue does NOT affect servers configured with the Intel Xeon E5-4600 series processors. When this issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).x on Intel Xeon E5-4600 series v2 processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. 314 Addressed an issue that can result in significant underutilization of processor cores for systems configured with 3 or more processors. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions.0 . Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. When this issue occurs. This issue does not impact servers configured with Intel Xeon E5-4600 series processors. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. the NIC will not PXE boot or be identified or used by the operating system. Instead. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When the issue occurs. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. but might impact other operating systems. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP Service Pack for ProLiant 2014. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-4600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp. the NIC will not PXE boot or be identified or used by the operating system.P61 315 Release Date: 05/02/2011 HP | Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL580 G5 System ROM .02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. When the issue occurs.06.0 Release Notes servers configured with Microsoft Windows Server 2012.06.HP ProLiant DL580 G5 (P61) Servers Version: 2011. When this issue occurs. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does not impact servers configured with Intel Xeon E5-4600 series processors.www2. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Instead.0 .com/bizsupport/TechSupport/Document.05. Addressed an issue where systems configured with Intel Xeon E5-4600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Online ROM Flash Component for Windows . Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. 06. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 .0 Release Notes Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: 316 None HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.HP Service Pack for ProLiant 2014.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved an issue where the system may hang when trying to apply custom settings using the ROM Based Setup Utility (RBSU) User Defined Defaults Option.06. 01. 2013. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.01(B). Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. it is not necessary to update to ver.10.10. All HP ProLiant DL580 G7 servers should update to the 10/01/2013 System ROM instead.www2. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.0 Release Notes Problems Fixed: Resolved an issue where the system may hang when trying to apply custom settings using the ROM Based Setup Utility (RBSU) User Defined Defaults Option. It does not affect any other ProLiant servers or any other HP ProLiant DL580 G7 System ROM revisions. 2013. The 10/01/2013 System ROM revision addresses the performance issue.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.01(B) did not change as compared to ver.HP Service Pack for ProLiant 2014.10.01 (B) (Critical) Important Note! Important Notes: IMPORTANT: The 07/01/2013 System ROM has an issue that can result in reduced performance and it has been removed from the HP Support Site. The actual BIOS Firmware contained within ver. The performance issue was unique to the 07/01/2013 System ROM revision for the DL580 G7. 2013. If using BIOS Firmware ver 2013.0 .jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows .com/bizsupport/TechSupport/Document.P65 Release Date: 10/01/2013 317 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014.hp.HP ProLiant DL580 G7 (P65) Servers Version: 2013. Deliverable Name: HP ProLiant DL580 G7 System ROM .10.01.10. Due to an issue with the thermal solution included in that revision of the System ROM. Known Issues: None Fixes Important Notes: IMPORTANT: The 07/01/2013 System ROM has an issue that can result in reduced performance and it has been removed from the HP Support Site. and have a guest OS utilizing 32-bit PAE Paging Mode. The performance issue was unique to the 07/01/2013 System ROM revision for the DL580 G7. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. the processor may be "throttled" to a reduced frequency when not necessary.HP Service Pack for ProLiant 2014. have Intel Hyperthreading enabled. or machine check exceptions or other unpredictable system behavior. Due to the potential severity of the issue addressed in this revision of the System ROM. to be affected by this issue the server must be operating in a virtualized environment. While all processors supported by this server have this issue. The actual BIOS Firmware contained within ver.0 Release Notes 10/01/2013 Previous Revision: 04/01/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed an issue with the 07/01/2013 revision of the System ROM that could result in decreased performance.06.10. This issue does NOT affect other revisions of the System ROM.01(B) did not change as compared to ver. The 10/01/2013 System ROM revision addresses the performance issue. HP | Service Pack for ProLiant 2014. general protection faults. Addressed an issue where the Intelligent Platform Management Interface (IPMI) based power reporting would not function properly and report an incorrect wattage from the installed Power Supplies. this System ROM upgrade is considered a critical fix.06.0 318 . All HP ProLiant DL580 G7 servers should update to the 10/01/2013 System ROM instead. Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. It does not affect any other ProLiant servers or any other HP ProLiant DL580 G7 System ROM revisions. 2013. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. HP Service Pack for ProLiant 2014. have Intel Hyperthreading enabled.02_04-01-2014 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL580 Gen8 System ROM .10.0 . Due to the potential severity of the issue addressed in this revision of the System ROM. Firmware Dependencies: None Problems Fixed: Addressed an issue with the 07/01/2013 revision of the System ROM that could result in decreased performance. This issue does NOT affect other revisions of the System ROM. Addressed an issue where the Intelligent Platform Management Interface (IPMI) based power reporting would not function properly and report an incorrect wattage from the installed Power Supplies.0 Release Notes 2013. Known Issues: None Online ROM Flash Component for Windows . the processor may be "throttled" to a reduced frequency when not necessary. general protection faults.01.HP ProLiant DL580 Gen8 (P79) Servers Version: 1. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. or machine check exceptions or other unpredictable system behavior.10. 2013.01(B). This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and have a guest OS utilizing 32-bit PAE Paging Mode.P79 319 Release Version: HP | Service Pack for ProLiant 2014. to be affected by this issue the server must be operating in a virtualized environment. this System ROM upgrade is considered a critical fix.06.01. Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. If using BIOS Firmware ver 2013.10. Due to an issue with the thermal solution included in that revision of the System ROM. it is not necessary to update to ver. While all processors supported by this server have this issue. 02_04-01-2014 Last Recommended or Critical Revision: 1. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 Release Notes 1.x or Microsoft Hyper-V on Intel Xeon E7-4800 series v2 processors.0 320 .06.01_03-19-2014 Previous Revision: 1.x or Microsoft Hyper-V on Intel Xeon E7-4800 series v2 processors. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed.HP Service Pack for ProLiant 2014. Known Issues: HP | Service Pack for ProLiant 2014.01_03-19-2014 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on VMware ESX 5. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on VMware ESX 5. jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL585 G2/G5/G6 System ROM .HP ProLiant DL585 G2/DL585 G5/DL585 G6 (A07) Servers Version: 2011.0 321 .HP Service Pack for ProLiant 2014.www2.0 Release Notes None Online ROM Flash Component for Windows .05. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.www2.A07 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 04/30/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.hp. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document.06.com/bizsupport/TechSupport/Document.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. 02. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.HP ProLiant DL585 G7 (A16) Servers Version: 2014. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.0 Release Notes Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).www2. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.06.hp. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.02 (Optional) HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Added latest product names of optional expansion cards for display in the ROM-Based Setup Utility (RBSU).0 . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2.jsp?locale=en_US&objectID=c0283837 5 322 Online ROM Flash Component for Windows .hp.HP Service Pack for ProLiant 2014.06.com/bizsupport/TechSupport/Document. 0 Release Notes Important Note! Important Notes: None Deliverable Name: HP ProLiant DL585 G7 System ROM Release Date: 02/02/2014 Last Recommended or Critical Revision: 12/17/2012 Previous Revision: 06/04/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved an issue where the HP NC375i Integrated Quad Port Gigabit Adapter could cause system instability.06. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. The instability could result in unexpected resets with Uncorrectable Chipset errors reported in the Integrated Management Log (IML). In some cases Operating Systems might report errors. This issue did not impact any other revisions of the System ROM. this issue might cause some versions of Microsoft Windows to boot into Recovery Mode. In addition. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.HP Service Pack for ProLiant 2014.06. Known Issues: None 323 Fixes HP | Service Pack for ProLiant 2014.0 . This issue did not impact any other revisions of the System ROM.06. this issue might cause some versions of Microsoft Windows to boot into Recovery Mode.com/bizsupport/TechSupport/Document.HP ProLiant DL785 G5/DL785 G6 (A15) Servers Version: 2011. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. In some cases Operating Systems might report errors.www2. Resolved an issue with the ROM-Based Setup Utility (RBSU) "Processor Core Disable (AMD Core Select)" Option.A15 324 Release Date: HP | Service Pack for ProLiant 2014. The 06/04/2013 revision of the System ROM might cause some Operating Systems to report the incorrect number of cores when the "Processor Core Disable (AMD Core Select)" is set to non-default values. The instability could result in unexpected resets with Uncorrectable Chipset errors reported in the Integrated Management Log (IML).jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant DL785 G5/G6 System ROM .hp.05. In addition.06. Known Issues: None Online ROM Flash Component for Windows .HP Service Pack for ProLiant 2014.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 Release Notes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved an issue where the HP NC375i Integrated Quad Port Gigabit Adapter could cause system instability.0 . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2. Resolved an issue where the user may be unable to select and use the '57600' and '115200' options in the "BIOS Serial Console Baud Rate" menu in the ROM-Based Setup Utility (RBSU).06.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.hp.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved an issue where the System ROM would not populate the System Enclosure or Chassis (type 3) SMBIOS record with text entered by the user in the Server Asset Tag Text Line in the ROM-Based Setup Utility (RBSU).hp. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.com/bizsupport/TechSupport/Document.com/bizsupport/TechSupport/Document.06. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 325 .0 Release Notes 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 12/04/2009 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. 31 (Recommended) Important Note! Important Notes: None Deliverable Name: HP ProLiant DL980 G7 System ROM .HP ProLiant DL980 G7 (P66) Servers Version: 2013.hp.06.P66 Release Date: 326 12/31/2013 Last Recommended or Critical Revision: HP | Service Pack for ProLiant 2014.0 Release Notes Firmware Dependencies: None Problems Fixed: Resolved an issue where the System ROM would not populate the System Enclosure or Chassis (type 3) SMBIOS record with text entered by the user in the Server Asset Tag Text Line in the ROM-Based Setup Utility (RBSU).0 . Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. Resolved an issue where the user may be unable to select and use the '57600' and '115200' options in the "BIOS Serial Console Baud Rate" menu in the ROM-Based Setup Utility (RBSU).12. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.www2. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows . Status 0xF6000000'00000972. TPM does not work in an HP | Service Pack for ProLiant 2014.0. TPM does not work in an Operation System after a system boot. Updated the embedded PXE Firmware to gPXE Version 4. Addressed an extremely rare issue where the system might stop responding and reboot unexpectedly during an Operating System boot or run time. Problems Fixed: Addressed an issue where the system may delay to POST or fail to boot when the TPM (Trusted Platform Module) is enabled.0 . Misc 0x00000000'00000000).0 Release Notes 12/31/2013 Previous Revision: 07/29/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the DDDC (Double Device Data Correction) aware POST (Power On Self Test) feature. This firmware addresses an issue where the system might stop responding during the deployment of VMware Vcenter 5. Bank 0x0000000E. this issue would typically be seen on every warm reboot. APIC ID 0x00000040. This error would typically be seen with a lot of following IML information: Uncorrectable Machine Check Exception (Board 0. Address 0x00000023'7B6E25C0.06. Customers who experience this event need to update to this version of the System ROM before contacting HP Support.582. Processor 2. Availability and Serviceability).HP Service Pack for ProLiant 2014. and reports a lot of Uncorrectable Machine Check Event in the IML (Integrated Management Log). this issue would typically be seen on every warm reboot.06. which will improve the system memory's RAS (Reliability. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None 327 Problems Fixed: Addressed an issue where the system may delay to POST or fail to boot when the TPM (Trusted Platform Module) is enabled.0 via PXE. 09 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant MicroServer Gen8 System ROM . Address 0x00000023'7B6E25C0. Bank 0x0000000E.06. Processor 2. Availability and Serviceability). APIC ID 0x00000040. Status 0xF6000000'00000972. Updated the embedded PXE Firmware to gPXE Version 4.HP ProLiant MicroServer Gen8 (J06) Servers Version: 2013.J06 Release Date: 11/09/2013 Last Recommended or Critical Revision: 08/24/2013 Previous Revision: 328 08/24/2013 HP | Service Pack for ProLiant 2014. This firmware addresses an issue where the system might stop responding during the deployment of VMware Vcenter 5. Known Issues: None Enhancements Added support for the DDDC (Double Device Data Correction) aware POST (Power On Self Test) feature.06.0 Release Notes Operation System after a system boot. This error would typically be seen with a lot of following IML information: Uncorrectable Machine Check Exception (Board 0.0.11.HP Service Pack for ProLiant 2014. which will improve the system memory's RAS (Reliability. Customers who experience this event need to update to this version of the System ROM before contacting HP Support. and reports a lot of Uncorrectable Machine Check Event in the IML (Integrated Management Log).582.0 via PXE. Misc 0x00000000'00000000). Online ROM Flash Component for Windows .0 . Addressed an extremely rare issue where the system might stop responding and reboot unexpectedly during an Operating System boot or run time. 20 or later. 30. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error.0 329 . the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. the system must be using Integrated Lights-Out (iLO) Firmware version 1. the system must be using Integrated Lights-Out (iLO) Firmware version 1. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15.0 Release Notes Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device.06. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives.20 or later.06.20 or later. the System ROM will now be able to detect HP | Service Pack for ProLiant 2014. If the system is configured to one of the new options without having iLO Firmware version 1. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). This allows the System ROM to attempt to boot the next device in the boot order. the Power-On Delay Option will function as if the No Delay option were chosen.HP Service Pack for ProLiant 2014. In some cases. For these new selections to function. If the system is configured to one of the new options without having iLO Firmware version 1. Previously. 30. the Power-On Delay Option will function as if the No Delay option were chosen.20 or later. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). For these new selections to function. In some cases. Previously. This allows the System ROM to attempt to boot the next device in the boot order.01 (Critical) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML110 G7 and DL120 G7 System ROM .0 Release Notes the invalid boot record and skip attempting to boot the device.07.06.HP Service Pack for ProLiant 2014.HP ProLiant ML110 G7/DL120 G7 (J01) Servers Version: 2013. Known Issues: None Online ROM Flash Component for Windows .J01 Release Date: 07/01/2013 Last Recommended or Critical Revision: 07/01/2013 Previous Revision: 12/04/2012 Firmware Dependencies: None Enhancements/New Features: None 330 Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to HP | Service Pack for ProLiant 2014. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).0 .06. general protection faults.0 Release Notes experience unexpected page faults. While all processors supported by this server have this issue. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Due to the potential severity of the issue addressed in this revision of the System ROM. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.06.10. to be affected by this issue the server must be operating in a virtualized environment. have Intel Hyperthreading enabled. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. or machine check exceptions or other unpredictable system behavior. Due to the potential severity of the issue addressed in this revision of the System ROM. and have a guest OS utilizing 32-bit PAE Paging Mode. While all processors supported by this server have this issue. this System ROM upgrade is considered a critical fix.0 . This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.HP Service Pack for ProLiant 2014. have Intel Hyperthreading enabled. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Known Issues: None Online ROM Flash Component for Windows .25 (Critical) 331 Important Note! HP | Service Pack for ProLiant 2014. and have a guest OS utilizing 32-bit PAE Paging Mode. to be affected by this issue the server must be operating in a virtualized environment.06.HP ProLiant ML310 G5/DL320 G5p (W05) Servers Version: 2010. or machine check exceptions or other unpredictable system behavior. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. general protection faults. this System ROM upgrade is considered a critical fix. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. 332 Known Issues: None HP | Service Pack for ProLiant 2014. blue screen. This issue affects platforms utilizing Intel Xeon 3100-series.W05 Release Date: 10/25/2010 Last Recommended or Critical Revision: 10/25/2010 Previous Revision: 07/11/2009 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D.0 . This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue. this System ROM upgrade is considered a critical fix. Intel Xeon 3300-series. or other unpredictable system behavior. kernel panic.0 Release Notes Important Notes: None Deliverable Name: HP ProLiant DL320 G5p/ML310 G5 System ROM . Intel Pentium Dual-Core Desktop E2000-series. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. and Intel Core 2 Duo Desktop E4000-series processors.06. HP strongly recommends immediate update to firmware revisions with required critical fixes.HP Service Pack for ProLiant 2014. Due to the potential severity of the issue addressed in this revision of the System ROM. 0x00000000)". Intel Xeon 3200-series.06. This issue affects platforms utilizing Intel Xeon 3100-series.0 .HP ProLiant ML310 G5p (W08) Servers Version: 2010. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue.06. This issue is not unique to HP ProLiant servers and could impact any system using affected processors. 0x00000000)". this System ROM upgrade is considered a critical fix. Intel Pentium Dual-Core Desktop E2000-series. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D.0 Release Notes Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. blue screen. HP strongly recommends immediate update to firmware revisions with required critical fixes.25 (Critical) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML310 G5p System ROM .06. Due to the potential severity of the issue addressed in this revision of the System ROM. Intel Xeon 3300-series.10.W08 333 Release Date: 10/25/2010 HP | Service Pack for ProLiant 2014. kernel panic. Intel Xeon 3200-series.HP Service Pack for ProLiant 2014. Known Issues: None Online ROM Flash Component for Windows . or other unpredictable system behavior. and Intel Core 2 Duo Desktop E4000-series processors. Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D. or other unpredictable system behavior. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None 334 Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit HP | Service Pack for ProLiant 2014. Intel Xeon 3300-series. HP strongly recommends immediate update to firmware revisions with required critical fixes. This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue.06. Intel Core 2 Duo Desktop E6000-series. This issue affects platforms utilizing Intel Xeon 3100-series. and Intel Core 2 Quad Q9000-series processors. Intel Pentium Dual-Core Desktop E2000-series. This issue is not unique to HP ProLiant servers and could impact any system using affected processors.0 .HP Service Pack for ProLiant 2014.0 Release Notes Last Recommended or Critical Revision: 10/25/2010 Previous Revision: 07/12/2009 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Resolved a processor issue where an unlikely and complex sequence of conditions operating in 64-bit mode could result in an application-level error. this System ROM upgrade is considered a critical fix. blue screen. kernel panic. Due to the potential severity of the issue addressed in this revision of the System ROM.06. Intel Core 2 Duo E8000series. 0x00000000)". Intel Xeon 3300-series.0 . This revision of the System ROM contains an updated version of Intel’s microcode for affected processors that addresses this issue.J04 Release Date: 11/09/2013 Last Recommended or Critical Revision: 08/24/2013 Previous Revision: 08/24/2013 Firmware Dependencies: 335 None HP | Service Pack for ProLiant 2014. Intel Core 2 Duo Desktop E6000-series. 0x00000000)". Note: This processor issue has resulted in the following error being logged to the Integrated Management Log on servers configured with the HP ProLiant Health Management Agents when configured in a Microsoft Virtual Server environment with large numbers of Virtual Machines (VM) simultaneously subjected to a heavy I/O workload (and may occur in other operating system environments): "An Unrecoverable System Error has occurred (Error code 0x0000002D.HP ProLiant ML310e Gen8 (J04) Servers Version: 2013. Known Issues: None Online ROM Flash Component for Windows .0 Release Notes mode could result in an application-level error. and Intel Core 2 Quad Q9000-series processors. kernel panic. blue screen.06. Intel Core 2 Duo E8000series. Due to the potential severity of the issue addressed in this revision of the System ROM.06. or other unpredictable system behavior.HP Service Pack for ProLiant 2014. HP strongly recommends immediate update to firmware revisions with required critical fixes. this System ROM upgrade is considered a critical fix. This issue is not unique to HP ProLiant servers and could impact any system using affected processors.09 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML310e Gen8 System ROM . This issue affects platforms utilizing Intel Xeon 3100-series.11. Intel Pentium Dual-Core Desktop E2000-series. 06. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). For these new selections to function. the Power-On Delay Option will function as if the No Delay option were chosen. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. Previously. In some cases.0 336 . 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay). This allows the System ROM to attempt to boot the next device in the boot order. HP | Service Pack for ProLiant 2014. the system must be using Integrated Lights-Out (iLO) Firmware version 1.20 or later. This allows the System ROM to attempt to boot the next device in the boot order. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device. the System ROM will now be able to detect the invalid boot record and skip attempting to boot the device.20 or later. 30. the system must be using Integrated Lights-Out (iLO) Firmware version 1. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. For these new selections to function. If the system is configured to one of the new options without having iLO Firmware version 1.20 or later. the Power-On Delay Option will function as if the No Delay option were chosen. If the system is configured to one of the new options without having iLO Firmware version 1. In some cases. 30.HP Service Pack for ProLiant 2014. Enhanced the System ROM's detection of valid boot devices such as USB Drive Keys or Hard Drives. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error.20 or later. 40 and 60 seconds (in addition to the previous options of No Delay and Random Delay).0 Release Notes Enhancements/New Features: Added additional options to the ROM Based Setup Utility (RBSU) Power-On Delay Option for delay times of 15. Previously. the System ROM may have attempted to boot certain bootable media with invalid boot records resulting in a Non-System Disk error.06. HP ProLiant ML310e Gen8 v2 (P78) Servers Version: 2014. Known Issues: None Online ROM Flash Component for Windows .HP Service Pack for ProLiant 2014.28 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML310e Gen8 v2 System ROM .03. HP | Service Pack for ProLiant 2014. This problem only affects servers with the 03/08/2014 revision of the System ROM.06.P78 Release Date: 03/28/2014 Last Recommended or Critical Revision: 03/08/2014 Previous Revision: 03/08/2013 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed an issue where servers using the 03/08/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test. This issue has no known impact with TPM functionality under normal operating system environments.06.0 337 .0 Release Notes Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). www2. This problem only affects servers with the 03/08/2014 revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.D21 Release Date: HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.06.06.02 (Critical) Important Note! Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: 338 HP ProLiant ML350 G5 System ROM .05.0 Release Notes Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed an issue where servers using the 03/08/2014 revision of the System ROM caused a problem with a Trusted Platform Module (TPM) operating system certification test. Known Issues: None Online ROM Flash Component for Windows . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This issue has no known impact with TPM functionality under normal operating system environments.hp.0 .HP ProLiant ML350 G5 (D21) Servers Version: 2011.com/bizsupport/TechSupport/Document. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.jsp?locale=en_US&objectID=c0283837 5 HP | Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. Once the system gets into this state.www2.0 Release Notes 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. Known Issues: None Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This is normally seen as the system hanging during system boot without anything displayed to video.www2.0 339 .06. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 Release Notes Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt.hp.02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.hp.HP ProLiant ML350 G6 (D22) Servers Version: 2013. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.07. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part.06.HP Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 340 Deliverable Name: HP ProLiant ML350 G6 System ROM . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Once the system gets into this state.www2.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows . the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.www2.com/bizsupport/TechSupport/Document. This is normally seen as the system hanging during system boot without anything displayed to video.com/bizsupport/TechSupport/Document. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.D22 HP | Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.06.0 . Intel Xeon Processor X5690. such as Linux RedHat 6. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. or machine check exceptions or other unpredictable system behavior.06.HP Service Pack for ProLiant 2014. and IRQ Balancing enabled in the Operating System. general protection faults. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. receive spurious interrupts or cause a network disconnect.0 Release Notes Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. this System ROM upgrade is considered a critical fix. As a result of this issue.2. This issue does not impact any processors that are not listed above. While all processors supported by this server have this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. to be affected by this issue the server must be operating in a virtualized environment. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. have Intel Hyperthreading enabled. Addressed an issue with the Intel Xeon Processor X5675. Due to the potential severity of the issue addressed in this revision of the System ROM. 341 Known Issues: None HP | Service Pack for ProLiant 2014. software may lose interrupts. and have a guest OS utilizing 32-bit PAE Paging Mode.0 .06. While all processors supported by this server have this issue. have Intel Hyperthreading enabled. this System ROM upgrade is considered a critical fix. general protection faults. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.2. As a result of this issue. software may lose interrupts. Known Issues: None 342 HP | Service Pack for ProLiant 2014.06. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This issue does not impact any processors that are not listed above. Addressed an issue with the Intel Xeon Processor X5675.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults.www2.06. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.0 . or machine check exceptions or other unpredictable system behavior. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior.HP Service Pack for ProLiant 2014. to be affected by this issue the server must be operating in a virtualized environment. Due to the potential severity of the issue addressed in this revision of the System ROM. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. and have a guest OS utilizing 32-bit PAE Paging Mode. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.com/bizsupport/TechSupport/Document.0 Release Notes Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. Intel Xeon Processor X5690. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. receive spurious interrupts or cause a network disconnect. such as Linux RedHat 6. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.hp. and IRQ Balancing enabled in the Operating System. 0 343 .06.J02 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/22/2013 Previous Revision: 12/22/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/22/2013 revisions. HP | Service Pack for ProLiant 2014.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML350e Gen8/ML350e Gen8 v2 System ROM .HP Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where servers using the 11/12/2013 or 12/22/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. the server might experience a Non-System Disk Error or not boot the intended media.0 Release Notes Online ROM Flash Component for Windows . When this issue occurs.06. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors.02. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.x on Intel Xeon E5-2400 series v2 processors.HP ProLiant ML350e Gen8/ML350e Gen8 v2 (J02) Servers Version: 2014. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Instead. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.x on Intel Xeon E5-2400 series v2 processors. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.06. When this issue occurs.HP Service Pack for ProLiant 2014. HP | Service Pack for ProLiant 2014. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/22/2013 revisions. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. Addressed an issue where servers using the 11/12/2013 or 12/22/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. When this issue occurs.0 344 . This issue does not impact servers configured with Intel Xeon E5-2400 series processors. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06.0 Release Notes Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. the NIC will not PXE boot or be identified or used by the operating system. When the issue occurs. the server might experience a Non-System Disk Error or not boot the intended media. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does not impact servers configured with Intel Xeon E5-2400 series processors. P72 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: 345 None. Online ROM Flash Component for Windows .02.HP ProLiant ML350p Gen8 (P72) Servers Version: 2014. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).06.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant ML350p Gen8 System ROM . When the issue occurs. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the NIC will not PXE boot or be identified or used by the operating system.06.HP Service Pack for ProLiant 2014. HP | Service Pack for ProLiant 2014. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).0 . Instead.0 Release Notes Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. When the issue occurs. This issue does not impact servers configured with Intel Xeon E5-2600 series processors.0 . Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. the NIC will not PXE boot or be identified or used by the operating system. the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.0 Release Notes Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.HP Service Pack for ProLiant 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. HP | Service Pack for ProLiant 2014. Instead. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Known Issues: None Fixes Important Notes: None 346 Firmware Dependencies: None.x on Intel Xeon E5-2600 series v2 processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).06.06. When this issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.0 . Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. Instead.06. When this issue occurs. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.02 (Critical) Important Note! 347 Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. When the issue occurs.0 Release Notes Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.x on Intel Xeon E5-2600 series v2 processors. the server might experience a Non-System Disk Error or not boot the intended media. the NIC will not PXE boot or be identified or used by the operating system. When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.06. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Online ROM Flash Component for Windows . Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the System ROM revision cannot be downgraded with the flash components available on HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).HP ProLiant ML370 G5 (P57) Server Version: 2011.05. jsp?locale=en_US&objectID=c0283837 5 Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. Once the system gets into this state. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.06.hp.0 Release Notes the HP Support site after updating to this revision of the System ROM.06.jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant ML370 G5 System ROM .HP Service Pack for ProLiant 2014.www2.com/bizsupport/TechSupport/Document.www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.P57 Release Date: 05/02/2011 Last Recommended or Critical Revision: 05/02/2011 Previous Revision: 10/25/2010 Firmware Dependencies: None Enhancements/New Features: Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults. This is normally seen as the system hanging during system boot without anything displayed to video.hp. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt.com/bizsupport/TechSupport/Document. Known Issues: None HP | Service Pack for ProLiant 2014. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 348 . A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.HP ProLiant ML370 G6/DL370 G6 (P63) Servers Version: 2013.com/bizsupport/TechSupport/Document.02 (Critical) 349 Important Note! Important Notes: HP | Service Pack for ProLiant 2014.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Resolved a very rare issue where the system may either hang during system boot or boot with configuration options set incorrectly when non-volatile storage becomes corrupt. Known Issues: None Enhancements Enhanced the System ROM flash update process to improve the reliability of System ROM updates and decrease the probability of unintended corruption of the flash part. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This is normally seen as the system hanging during system boot without anything displayed to video.www2. This revision of the System ROM will restore configuration defaults when nonvolatile storage becomes corrupt. Once the system gets into this state. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.hp.jsp?locale=en_US&objectID=c0283837 5 Online ROM Flash Component for Windows .06.06.com/bizsupport/TechSupport/Document.hp.07. Note: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.0 .0 Release Notes Fixes Important Notes: As enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.www2. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. the maintenance jumper can be utilized to recover operation of the system and restore configuration defaults.HP Service Pack for ProLiant 2014. www2.hp. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06.0 350 .jsp?locale=en_US&objectID=c0283837 5 Deliverable Name: HP ProLiant ML370 G6/DL370 G6 System ROM . HP | Service Pack for ProLiant 2014.06. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.HP Service Pack for ProLiant 2014. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Due to the potential severity of the issue addressed in this revision of the System ROM. Addressed an issue with the Intel Xeon Processor X5675. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables.0 Release Notes Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility.P63 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. this System ROM upgrade is considered a critical fix. While all processors supported by this server have this issue. general protection faults. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Intel Xeon Processor X5690. or machine check exceptions or other unpredictable system behavior.com/bizsupport/TechSupport/Document. to be affected by this issue the server must be operating in a virtualized environment. have Intel Hyperthreading enabled. and have a guest OS utilizing 32-bit PAE Paging Mode. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. As a result of this issue.0 351 . have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. Due to the potential severity of the issue addressed in this revision of the System ROM. to be affected by this issue the server must be operating in a virtualized environment. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. Intel Xeon Processor X5690. and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. While all processors supported by this server have this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. Addressed an issue with the Intel Xeon Processor X5675.2. software may lose interrupts. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.hp. HP | Service Pack for ProLiant 2014.06. This issue does not impact any processors that are not listed above. have Intel Hyperthreading enabled. such as Linux RedHat 6.com/bizsupport/TechSupport/Document. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors.0 Release Notes This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above.HP Service Pack for ProLiant 2014.www2. This issue does not impact any processors that are not listed above. receive spurious interrupts or cause a network disconnect. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. or machine check exceptions or other unpredictable system behavior.06. and have a guest OS utilizing 32-bit PAE Paging Mode. and IRQ Balancing enabled in the Operating System. this System ROM upgrade is considered a critical fix. general protection faults. HP ProLiant SL210t Gen8 (P83) Servers Version: 2014.2. receive spurious interrupts or cause a network disconnect. This issue is not unique to HP ProLiant servers and HP | Service Pack for ProLiant 2014.0 . As a result of this issue.HP Service Pack for ProLiant 2014.02.P83 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL210t Gen8 System ROM .06. Known Issues: None Online ROM Flash Component for Windows . and IRQ Balancing enabled in the Operating System. such as Linux RedHat 6.x on Intel Xeon E5-2600 series v2 processors. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). Problems Fixed: 352 Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06.0 Release Notes Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems. software may lose interrupts. Instead. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs.06. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.06.x on Intel Xeon E5-2600 series v2 processors. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. When this issue occurs. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.0 353 . the NIC will not PXE boot or be identified or used by the operating system. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is HP | Service Pack for ProLiant 2014. the server might experience a Non-System Disk Error or not boot the intended media.HP Service Pack for ProLiant 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. When this issue occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors. When the issue occurs.0 Release Notes could impact any system using affected processors operating with the conditions listed. 0 .0 Release Notes not marked as Active.02. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Instead. When the issue occurs. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). When this issue occurs.06. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL230s/250s/270s Gen8/270s Gen8 SE System ROM . Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. When this issue occurs.HP Service Pack for ProLiant 2014. Online ROM Flash Component for Windows .P75 Release Date: 02/10/2014 354 Last Recommended or Critical Revision: 12/20/2013 HP | Service Pack for ProLiant 2014.HP ProLiant SL230s/SL250s/SL270s Gen8/SL270s Gen8 SE (P75) Servers Version: 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2600 series processors.06. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the NIC will not PXE boot or be identified or used by the operating system. the server might experience a Non-System Disk Error or not boot the intended media. 0 Release Notes Previous Revision: 12/20/2013 Firmware Dependencies: None. Instead. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot.06.06. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. When this issue occurs. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Known Issues: None 355 Fixes HP | Service Pack for ProLiant 2014. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. the NIC will not PXE boot or be identified or used by the operating system. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the server might experience a Non-System Disk Error or not boot the intended media. Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).x on Intel Xeon E5-2600 series v2 processors. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.HP Service Pack for ProLiant 2014. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This issue does not impact servers configured with Intel Xeon E5-2600 series processors. When this issue occurs.0 . This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. When the issue occurs. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). 356 HP | Service Pack for ProLiant 2014. Instead. When the issue occurs. When this issue occurs. When this issue occurs. the NIC will not PXE boot or be identified or used by the operating system. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed. the server might experience a Non-System Disk Error or not boot the intended media.0 Release Notes Important Notes: None Firmware Dependencies: None. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2600 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. This issue does NOT affect servers configured with the Intel Xeon E5-2600 series processors.HP Service Pack for ProLiant 2014.06. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.06. This issue does NOT impact any System ROM revisions other than the 11/14/2013 and 12/20/2013 revisions. This issue does not impact servers configured with Intel Xeon E5-2600 series processors.0 . the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).x on Intel Xeon E5-2600 series v2 processors. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Addressed an issue where servers using the 11/14/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. Addressed an issue where systems configured with Intel Xeon E5-2600 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform. 06. Resolved an issue where industry standard tools.0 Release Notes Online ROM Flash Component for Windows . Problems Fixed: Resolved an issue that could result in a server reset or the inability to boot. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU). HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.HP ProLiant SL335s G7 (A24) Servers Version: 2012.08 (Recommended) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL335s G7 System ROM .0 . 357 Resolved a rare issue where the system and IML may indicate an uncorrectable reset when upgrading to the 09/01/2012 system ROM. and HP utilities may report less Level 3 (L3) cache than expected.A24 Release Date: 12/08/2012 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 09/01/2012 Firmware Dependencies: None Enhancements/New Features: Optimized the memory settings to improve the reliability of the memory system. operating systems.06. Servers should be updated to this revision of the system ROM to minimize the potential for a system reset or the inability to boot.12. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000.HP Service Pack for ProLiant 2014.06.0 Release Notes Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Resolved an issue that could result in a server reset or the inability to boot.0 358 . Servers should be updated to this revision of the system ROM to minimize the potential for a system reset or the inability to boot.com/bizsupport/TechSupport/Document. Resolved an issue where industry standard tools.hp. Added the latest product names of optional expansion cards and updated language translations (for nonEnglish modes) in the ROM-Based Setup Utility (RBSU).02 (Critical) Important Note! Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM.07.www2.HP ProLiant SL390s G7 (P69) Servers Version: 2013. Online ROM Flash Component for Windows . and HP utilities may report less Level 3 (L3) cache than expected.06. Resolved a rare issue where the system and IML may indicate an uncorrectable reset when upgrading to the 09/01/2012 system ROM.jsp?locale=en_US&objectID=c0283837 HP | Service Pack for ProLiant 2014. operating systems. Known Issues: None Enhancements Optimized the memory settings to improve the reliability of the memory system. HP Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. Intel Xeon Processor X5690. have Intel Hyperthreading enabled. Addressed an issue with the Intel Xeon Processor X5675. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above. this System ROM upgrade is considered a critical fix. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.0 Release Notes 5 Deliverable Name: HP ProLiant SL390s G7 System ROM . and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. and have a guest OS utilizing 32-bit PAE Paging Mode. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. to be affected by this issue the server must be operating in a virtualized environment. As a HP | Service Pack for ProLiant 2014. This issue does not impact any processors that are not listed above. or machine check exceptions or other unpredictable system behavior. such as Linux RedHat 6. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue.06. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. While all processors supported by this server have this issue. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.06.P69 Release Date: 07/02/2013 Last Recommended or Critical Revision: 07/02/2013 Previous Revision: 12/02/2012 Firmware Dependencies: None Enhancements/New Features: None.2. general protection faults. and IRQ Balancing enabled in the Operating System.0 359 . Due to the potential severity of the issue addressed in this revision of the System ROM. the System ROM revision cannot be downgraded with the flash components available on the HP Support site after updating to this revision of the System ROM. and have a guest OS utilizing 32-bit PAE Paging Mode. to be affected by this issue the server must be operating in a virtualized environment. general protection faults. Intel Xeon Processor X5690. Addressed an issue with the Intel Xeon Processor X5675.www2.06. have a hypervisor that enables Intel VT FlexPriority and Extended Page Tables. software may lose interrupts. This issue does not impact any processors that are not listed above.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document. such as Linux RedHat 6. This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. This System ROM upgrade is considered a critical fix for customers utilizing the affected processors. A customer can downgrade the System ROM by creating a new flash component with the older System ROM revision as indicated in Advisory C02838375 available at the following link: http://h20000. Known Issues: None Fixes Important Notes: Enhancing the flash upgrade process requires modifications to both the System ROM and the flash update utility. This issue is not unique to HP ProLiant servers and could impact any system utilizing affected processors operating with the conditions listed above.hp. receive spurious interrupts or cause a network disconnect. This issue is not unique to HP ProLiant servers and could impact any system using the affected processors listed above. software may lose interrupts. Due to the potential severity of the issue addressed in this revision of the System ROM. This revision of the System ROM contains and updated version of Intel's microcode that addresses this issue. and IRQ Balancing enabled in the Operating System.0 360 . and Intel Xeon Processor X5687 where a rare and complex combination of data and environmental conditions may result in some instructions not executing properly causing unpredictable system behavior. receive spurious interrupts or cause a network disconnect. As a result of this issue.jsp?locale=en_US&objectID=c0283837 5 Firmware Dependencies: None Problems Fixed: Addressed a processor issue under which a rare and complex sequence of internal processor microarchitecture events that occur in specific operating environments could cause a server system to experience unexpected page faults. have Intel Hyperthreading enabled.2. While all processors supported by this server have this issue. or machine check exceptions or other unpredictable system behavior. this System ROM upgrade is considered a critical fix. HP | Service Pack for ProLiant 2014.06. Addressed an issue where the platform may experience networking issues under heavy workloads with Operating Systems.0 Release Notes result of this issue. HP ProLiant SL4540 Gen8 (P74) Servers Version: 2014.0 361 . This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue.x on Intel Xeon E5-2400 series v2 processors.06. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors.HP Service Pack for ProLiant 2014. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM HP | Service Pack for ProLiant 2014.02. Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5.06.0 Release Notes Known Issues: None Online ROM Flash Component for Windows . This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.P74 Release Date: 02/10/2014 Last Recommended or Critical Revision: 12/20/2013 Previous Revision: 12/20/2013 Firmware Dependencies: None Enhancements/New Features: Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU).10 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL4540 Gen8 System ROM . This revision of the System ROM contains an updated version of Intel's microcode that addresses this issue. the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT affect servers configured with the Intel Xeon E5-2400 series processors. Addressed an issue where servers using the 11/12/2013 or 12/20/2013 revisions of the System ROM might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output. the NIC will not PXE boot or be identified or used by the operating system. When this issue occurs. When the issue occurs. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Known Issues: None Fixes Important Notes: None Firmware Dependencies: None Problems Fixed: Addressed a processor issue which can result in a Blue Screen of Death (BSOD) in a Windows virtual machine or Linux Kernel Panic in a Linux virtual machine when running on Microsoft Hyper-V or VMware ESX 5. When this issue occurs.HP Service Pack for ProLiant 2014. This issue is not unique to HP ProLiant servers and could impact any system using affected processors operating with the conditions listed.0 362 . the server might experience a Non-System Disk Error or not boot the intended media. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions.0 Release Notes might not be able to boot certain operating system installations that install a Master Boot Record that is not marked as Active.06. Instead. Addressed an extremely rare issue that can result in a system configured with Intel Xeon E5-2400 v2 series HP | Service Pack for ProLiant 2014. When this issue occurs.06. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. This issue does NOT impact any System ROM revisions other than the 11/12/2013 and 12/20/2013 revisions. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.x on Intel Xeon E5-2400 series v2 processors. This issue does not impact servers configured with Intel Xeon E5-2400 series processors. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL). 11. Addressed an issue where the System ROM does not properly retry booting certain Network Adapters under some conditions including when the user presses F12 to attempt a PXE boot. Addressed an issue where systems configured with Intel Xeon E5-2400 v2 series processors and an HP 331FLR FlexLOM or HP NC332T Network Controller might see intermittent issues with the NIC not being detected by the platform.A31 Release Date: 11/02/2013 Last Recommended or Critical Revision: 12/08/2012 Previous Revision: 363 06/05/2013 HP | Service Pack for ProLiant 2014.0 Release Notes processors becoming unresponsive early in the POST boot process after an uncorrectable memory error occurs. Online ROM Flash Component for Windows . This issue does not impact servers configured with Intel Xeon E5-2400 series processors. When this issue occurs.02 (Optional) Important Note! Important Notes: None Deliverable Name: HP ProLiant SL4545 G7 System ROM .06.HP Service Pack for ProLiant 2014. Known Issues: None Enhancements Added support for the latest names for PCIe expansion devices to the ROM-Based Setup Utility (RBSU). the NIC will not PXE boot or be identified or used by the operating system. When the issue occurs. Instead. the System ROM will only attempt to boot the Network Adapter one time and then will continue trying to boot devices in the order specified by the Standard Boot Order (IPL).HP ProLiant SL4545 G7 (A31) Servers Version: 2013.06. the server will indicate an early boot progress of 20% and a "Memory and QPI Link Initialization Start" message will be displayed on the screen output.0 . Known Issues: None Online ROM Flash Component for Windows .0 Release Notes Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards in the ROM-Based Setup Utility (RBSU).HP ProLiant XL220a Gen8 v2 (P94) Servers Version: 2014.0 .06. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: Added the latest product names of optional expansion cards in the ROM-Based Setup Utility (RBSU).29 (Recommended) Important Note! Important Notes: None 364 Deliverable Name: HP ProLiant XL220a Gen8 v2 System ROM .06.HP Service Pack for ProLiant 2014.04.P94 HP | Service Pack for ProLiant 2014. Firmware Dependencies: None Enhancements/New Features: This is the initial version of the firmware.0 Release Notes Release Date: 04/29/2014 Last Recommended or Critical Revision: This is the initial version of the firmware. Known Issues: None 365 HP | Service Pack for ProLiant 2014.0 . Previous Revision: This is the initial version of the firmware.06.HP Service Pack for ProLiant 2014.06. Problems Fixed: None Known Issues: None Enhancements Important Notes: None Firmware Dependencies: None Enhancements/New Features: This is the initial version of the firmware. HP | Service Pack for ProLiant 2014.0.0 (D) (Optional) Enhancements Enhanced component-level logging has been implemented in the Smart Component installer.6 Kernel or later o Fixed issue where the remote console mouse does not function properly on RedHat Enterprise Linux 4 Update 8 with iLO3 based servers.Lights-Out Management Top HP iLO High-Performance Mouse for Linux Version: 1.06.LOG.HP Service Pack for ProLiant 2014. Therefore you don't need to install hp-ilo if you are running Red Hat Enterprise Linux 5 Update 3 and later. Driver .0 Release Notes Top Driver .2.rhel5 (Optional) Important Note! The hp-ilo features are now included in the Red Hat Enterprise Linux 5 Update 3 and later.2. The generated log file will be located on the target system in the %SystemRoot%\cpqsystem\log directory under the name CPQSETUP. HP ProLiant Channel Interface Device Driver for iLO for Red Hat Enterprise Linux 5 (AMD64/EM64T) Version: 8.5.1-1 (Optional) Prerequisites In order for the HP iLO High-Performance Mouse to install and work properly. Previously released version (1.3. Fixes Enhancements Added support for HP ProLiant Gen8 and Gen8 v2 servers.06.0-1. your server must have the following: o o o embedded iLO2 or later Xfree86 or xorg-x11 install 2.Chipset HP ProLiant PCI-express Power Management Update for Windows Version: 1.0 366 .0) that claimed iLO3 support did not function as expected under RHEL4 update 8 on iLO3 based servers. Therefore you don't need to install hp-ilo if you are running Red Hat Enterprise Linux 5 Update 3 and later.18.16.06. HP ProLiant Integrated Lights-Out Management Interface Driver for Windows Server 2003/2008 x64 Editions Version: 1.16. HP ProLiant Integrated Lights-Out Management Interface Driver for Windows Server 2012 Version: 1.0.16.06.rhel5 (Optional) Important Note! The hp-ilo features are now included in the Red Hat Enterprise Linux 5 Update 3 and later.0-1.HP Service Pack for ProLiant 2014. which was incorrectly enabled in version 1.5.0. This will prevent HP Smart Update Manager from showing that both drivers are available for installation under Windows Server 2012 on HP ProLiant G6 servers.0 (Optional) 367 Enhancements Add support for Microsoft Windows Server 2012 R2 on selected HP ProLiant G6 servers.0 .17. use the HP ProLiant Integrated Lights-Out Management Interface Driver for Windows Server 2012. version 1.0 Release Notes Enhancements  Added support for newer distribution kernels.0 (Optional) Fixes Fixed a problem related to the Insight Management Agents and WBEM Providers re-establishing communications with iLO after iLO is rebooted. For Windows Server 2012 support.0 or later.0.0.0 (B) (Optional) Fixes Disable installation under Windows Server 2012. HP ProLiant Channel Interface Device Driver for iLO for Red Hat Enterprise Linux 5 (x86) Version: 8.0. instead. HP ProLiant Integrated Lights-Out Management Interface Driver for Windows Server 2003/2008 Version: 1.0. HP | Service Pack for ProLiant 2014. Enhancements  Added support for newer distribution kernels. 06.10.12-2 (Optional) Enhancements These drivers now support the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o o o o o o o o o o o HP BladeSystem Dual NC370i Multifunction Gigabit Server Adapter HP NC371i Integrated PCI-X Multifunction Gigabit Server Adapter HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC373i Integrated Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 530FLB Adapter HP Ethernet 10Gb 2-port 530M Adapter HP Ethernet 10Gb 2-port 530SFP+ Adapter HP Ethernet 10Gb 2-port 530T Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP Ethernet 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom 1/10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 7.06.10.0 368 .0 Release Notes Top Driver .HP Service Pack for ProLiant 2014.12-2 (Optional) HP | Service Pack for ProLiant 2014.Network HP Broadcom 1/10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 5 i686 Version: 7. 12-2 (Optional) Enhancements These drivers now support the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter 369 Supported Devices and Features HP | Service Pack for ProLiant 2014.10.06.06.HP Service Pack for ProLiant 2014.0 .0 Release Notes Enhancements These drivers now support the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o o o o o o o o o o o HP BladeSystem Dual NC370i Multifunction Gigabit Server Adapter HP NC371i Integrated PCI-X Multifunction Gigabit Server Adapter HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC373i Integrated Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 530FLB Adapter HP Ethernet 10Gb 2-port 530M Adapter HP Ethernet 10Gb 2-port 530SFP+ Adapter HP Ethernet 10Gb 2-port 530T Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP Ethernet 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom 1/10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 6 i686 Version: 7. 10.0 370 .06.06.HP Service Pack for ProLiant 2014.0 Release Notes These drivers support the following network adapters: o o o o o o o o o o o o o o o o o o o o o o o HP BladeSystem Dual NC370i Multifunction Gigabit Server Adapter HP NC371i Integrated PCI-X Multifunction Gigabit Server Adapter HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC373i Integrated Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 530FLB Adapter HP Ethernet 10Gb 2-port 530M Adapter HP Ethernet 10Gb 2-port 530SFP+ Adapter HP Ethernet 10Gb 2-port 530T Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP Ethernet 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom 1/10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 7.12-2 (Optional) Enhancements These drivers now support the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP BladeSystem Dual NC370i Multifunction Gigabit Server Adapter HP NC371i Integrated PCI-X Multifunction Gigabit Server Adapter HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC373i Integrated Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP | Service Pack for ProLiant 2014. 10.12-2 (Optional) Enhancements These drivers now support the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o o o o o HP BladeSystem Dual NC370i Multifunction Gigabit Server Adapter HP NC371i Integrated PCI-X Multifunction Gigabit Server Adapter HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC373i Integrated Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 530FLB Adapter HP Ethernet 10Gb 2-port 530M Adapter HP Ethernet 10Gb 2-port 530SFP+ Adapter HP Ethernet 10Gb 2-port 530T Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP Ethernet 10Gb 2-port 533FLR-T Adapter HP | Service Pack for ProLiant 2014.06.06.0 371 .HP Service Pack for ProLiant 2014.0 Release Notes o o o o o o o o o o o o o o o o HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 530FLB Adapter HP Ethernet 10Gb 2-port 530M Adapter HP Ethernet 10Gb 2-port 530SFP+ Adapter HP Ethernet 10Gb 2-port 530T Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP Ethernet 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom 1/10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 11 i586 Version: 7. 06.12-2 (Optional) Enhancements These drivers now support the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o o o o o o o o o o o HP BladeSystem Dual NC370i Multifunction Gigabit Server Adapter HP NC371i Integrated PCI-X Multifunction Gigabit Server Adapter HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC373i Integrated Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 530FLB Adapter HP Ethernet 10Gb 2-port 530M Adapter HP Ethernet 10Gb 2-port 530SFP+ Adapter HP Ethernet 10Gb 2-port 530T Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP Ethernet 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP | Service Pack for ProLiant 2014.10.0 372 .06.0 Release Notes o o o o o o HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom 1/10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 7.HP Service Pack for ProLiant 2014. 0 Release Notes HP Broadcom 10/20GbE Multifunction Drivers for Windows Server 2008 Version: 7.0 (Optional) Enhancements This component now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter Supported Devices and Features This driver supports the following HP Broadcom 10/20GbE Multifunction network adapters: o o o o o o o o o o o o o o HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifunction BL-c Adapter HP Flex-10 10Gb 2-port 530FLB Adapter HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter HP Flex-10 10Gb 2-port 530M Adapter HP Ethernet 10Gb 2-port 530SFP+ Adapter HP Ethernet 10Gb 2-port 530T Adapter HP Ethernet 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom 10/20GbE Multifunction Drivers for Windows Server x64 Editions Version: 7.HP Service Pack for ProLiant 2014.0 (Optional) Enhancements This component now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter Supported Devices and Features This driver supports the following HP Broadcom 10/20GbE Multifunction network adapters: o o o HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifunction BL-c Adapter HP Flex-10 10Gb 2-port 530FLB Adapter HP | Service Pack for ProLiant 2014.06.8.06.0 373 .10.8.10. HP | Service Pack for ProLiant 2014.06.0 374 .0 Release Notes o o o o o o o o o o o HP Ethernet 10Gb 2-port 530FLR-SFP+ Adapter HP Flex-10 10Gb 2-port 530M Adapter HP Ethernet 10Gb 2-port 530SFP+ Adapter HP Ethernet 10Gb 2-port 530T Adapter HP Ethernet 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom 1Gb Driver for Windows Server 2008 Version: 16.0.4. Supported Devices and Features This driver supports the following HP Broadcom network adapters: o o o o o o o o o o o o HP NC105i Integrated PCI Express Gigabit Server Adapter HP NC107i Integrated PCI Express Gigabit Server Adapter HP NC325m PCIe Quad Port Adapter HP NC326i Integrated Dual Port PCI Express Gigabit Server Adapter HP NC326m PCIe Dual Port Adapter HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331i-SPI Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter HP Ethernet 1Gb 2-port 332T Adapter HP Broadcom 1Gb Driver for Windows Server x64 Editions Version: 16. This driver corrects an issue that could result in a Windows Stop Error (BSOD) when a large number of ports are repeatedly disabled. This driver corrects an issue that could result in a Windows Stop Error (BSOD) when a large number of ports are repeatedly disabled.0.HP Service Pack for ProLiant 2014.1 (Optional) Fixes This driver corrects an issue that could result in halted traffic when configuring jumbo frame size to 9000.4.06.1 (Optional) Fixes This driver corrects an issue that could result in halted traffic when configuring jumbo frame size to 9000. 0 (C) (Optional) Fixes The drivers in this component now have correct Microsoft Hardware Quality Labs (WHQL) certification.06.HP Service Pack for ProLiant 2014.0 Release Notes Supported Devices and Features This driver supports the following HP Broadcom network adapters: o o o o o o o o o o o o HP NC105i Integrated PCI Express Gigabit Server Adapter HP NC107i Integrated PCI Express Gigabit Server Adapter HP NC325m PCIe Quad Port Adapter HP NC326i Integrated Dual Port PCI Express Gigabit Server Adapter HP NC326m PCIe Dual Port Adapter HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331i-SPI Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter HP Ethernet 1Gb 2-port 332T Adapter HP Broadcom 1Gb Multifunction Drivers for Windows Server 2008 Version: 7.06. Supported Devices and Features HP | Service Pack for ProLiant 2014. Supported Devices and Features This driver supports the following network adapters: o o o o o o o o o HP BladeSystem Dual NC370i Multifunction Gigabit Server Adapter HP NC371i Integrated PCI-X Multifunction Gigabit Server Adapter HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC373i Integrated Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP Broadcom 1Gb Multifunction Drivers for Windows Server x64 Editions Version: 7.8.8.50.0 375 .50.0 (D) (Optional) Fixes The drivers in this component now have correct Microsoft Hardware Quality Labs (WHQL) certification. 06.7.0 .8.1e-1 (Optional) Enhancements Initial release.7. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for Red Hat Enterprise Linux 5 Update 10 x86_64 Version: 0. 376 Supported Devices and Features HP | Service Pack for ProLiant 2014.8.HP Service Pack for ProLiant 2014.06.0 Release Notes This driver supports the following network adapters: o o o o o o o o o HP BladeSystem Dual NC370i Multifunction Gigabit Server Adapter HP NC371i Integrated PCI-X Multifunction Gigabit Server Adapter HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC373i Integrated Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP Broadcom Linux iSCSI Offload IO Daemon for Red Hat Enterprise Linux 5 Update 10 i686 Version: 0.1e-1 (Optional) Enhancements Initial release. Supported Devices and Features HP | Service Pack for ProLiant 2014.8.7.0 .06.1e-1 (Optional) Fixes This software now correctly decodes the iface_subnet_mask for IPv6.HP Service Pack for ProLiant 2014.06.7. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for Red Hat Enterprise Linux 5 Update 9 x86_64 Version: 0.8.0 Release Notes These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for Red Hat Enterprise Linux 5 Update 9 i686 Version: 0.1e-1 (Optional) 377 Fixes This software now correctly decodes the iface_subnet_mask for IPv6. 8.1e-1 (Optional) 378 Fixes This software now correctly decodes the iface_subnet_mask for IPv6.06. Supported Devices and Features HP | Service Pack for ProLiant 2014.0 Release Notes These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for Red Hat Enterprise Linux 6 Update 4 i686 Version: 0.HP Service Pack for ProLiant 2014. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for Red Hat Enterprise Linux 6 Update 4 x86_64 Version: 0.7.7.1e-1 (Optional) Fixes This software now correctly decodes the iface_subnet_mask for IPv6.8.06.0 . HP Service Pack for ProLiant 2014.0 .7. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for Red Hat Enterprise Linux 6 Update 5 x86_64 Version: 0.8.1e-1 (Optional) 379 Enhancements Initial release.1e-1 (Optional) Enhancements Initial release.8.06. Supported Devices and Features HP | Service Pack for ProLiant 2014.06.7.0 Release Notes These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for Red Hat Enterprise Linux 6 Update 5 i686 Version: 0. 06.0 .8.7. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 11 SP2 x86_64 Version: 0.8.1e-1 (Optional) Fixes This software now correctly decodes the iface_subnet_mask for IPv6. Supported Devices and Features HP | Service Pack for ProLiant 2014.7.06.1e-1 (Optional) 380 Fixes This software now correctly decodes the iface_subnet_mask for IPv6.HP Service Pack for ProLiant 2014.0 Release Notes These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 11 SP2 i586 Version: 0. 7.0 Release Notes These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 11 SP3 i586 Version: 0.06. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom Linux iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 11 SP3 x86_64 Version: 0. Supported Devices and Features HP | Service Pack for ProLiant 2014.1e-1 (Optional) Fixes This software now correctly decodes the iface_subnet_mask for IPv6.06.0 .HP Service Pack for ProLiant 2014.8.1e-1 (Optional) 381 Fixes This software now correctly decodes the iface_subnet_mask for IPv6.8.7. 06. This driver addresses an issue that results in the lspci command produces unknown messages in its output. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o HP NC105i PCIe Gigabit Server Adapter HP NC107i PCIe Quad Port Gigabit Server Adapter HP NC320m PCI Express Gigabit Server Adapter HP NC325m Quad Port PCIe Gigabit Server Adapter HP NC326i PCIe Dual Port Gigabit Server Adapter HP NC326m Dual Port PCIe Gigabit Server Adapter HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331i-SPI Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter HP Ethernet 1Gb 2-port 332T Adapter 382 HP | Service Pack for ProLiant 2014. This driver addresses an issue which results in a system in S1 sleep mode failing to wake up when it receives a Magic Packet.06.0 .HP Service Pack for ProLiant 2014.134f-2 (Optional) Fixes This driver addresses an issue where Frame Check Sequence (FCS) Receive (Rx) errors occur randomly when a system is connected to a Dell PowerConnect switch.0 Release Notes These drivers support the following network adapters: o o o o o o o o o o o HP NC382i Integrated Dual Port Multifunction Gigabit Server Adapter HP NC382m Dual Port 1GbE Multifunction BL-c Adapter HP NC382T PCI Express Dual Port Gigabit Server Adapter HP NC532i Dual Port 10GbE Multifunction BL-c Adapter HP NC532m Dual Port 10GbE Multifuntion BL-c Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 5 i686 Version: 3. This driver addresses some link status issues that occur when the networking cable is not plugged in. 134f-2 (Optional) Fixes This driver addresses an issue where Frame Check Sequence (FCS) Receive (Rx) errors occur randomly when a system is connected to a Dell PowerConnect switch. This driver addresses some link status issues that occur when the networking cable is not plugged in.HP Service Pack for ProLiant 2014.0 Release Notes HP Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 3. This driver addresses an issue that results in the lspci command produces unknown messages in its output.06.134f-2 (Optional) Fixes This driver addresses an issue where Frame Check Sequence (FCS) Receive (Rx) errors occur randomly when a system is connected to a Dell PowerConnect switch. This driver addresses an issue which results in a system in S1 sleep mode failing to wake up when it receives a Magic Packet. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o HP NC105i PCIe Gigabit Server Adapter HP NC107i PCIe Quad Port Gigabit Server Adapter HP NC320m PCI Express Gigabit Server Adapter HP NC325m Quad Port PCIe Gigabit Server Adapter HP NC326i PCIe Dual Port Gigabit Server Adapter HP NC326m Dual Port PCIe Gigabit Server Adapter HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331i-SPI Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter HP Ethernet 1Gb 2-port 332T Adapter HP Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 6 i686 Version: 3. HP | Service Pack for ProLiant 2014. This driver addresses some link status issues that occur when the networking cable is not plugged in. This driver addresses an issue which results in a system in S1 sleep mode failing to wake up when it receives a Magic Packet.0 383 . This driver addresses an issue that results in the lspci command produces unknown messages in its output.06. This driver addresses an issue which results in a system in S1 sleep mode failing to wake up when it receives a Magic Packet.0 Release Notes Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o HP NC105i PCIe Gigabit Server Adapter HP NC107i PCIe Quad Port Gigabit Server Adapter HP NC320m PCI Express Gigabit Server Adapter HP NC325m Quad Port PCIe Gigabit Server Adapter HP NC326i PCIe Dual Port Gigabit Server Adapter HP NC326m Dual Port PCIe Gigabit Server Adapter HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331i-SPI Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter HP Ethernet 1Gb 2-port 332T Adapter HP Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 3.06.06. This driver addresses some link status issues that occur when the networking cable is not plugged in.HP Service Pack for ProLiant 2014. This driver addresses an issue that results in the lspci command produces unknown messages in its output.0 .134f-2 (Optional) Fixes This driver addresses an issue where Frame Check Sequence (FCS) Receive (Rx) errors occur randomly when a system is connected to a Dell PowerConnect switch. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o HP NC105i PCIe Gigabit Server Adapter HP NC107i PCIe Quad Port Gigabit Server Adapter HP NC320m PCI Express Gigabit Server Adapter HP NC325m Quad Port PCIe Gigabit Server Adapter HP NC326i PCIe Dual Port Gigabit Server Adapter HP NC326m Dual Port PCIe Gigabit Server Adapter HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331i-SPI Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter 384 HP | Service Pack for ProLiant 2014. This driver addresses an issue that results in the lspci command produces unknown messages in its output.134f-2 (Optional) Fixes This driver addresses an issue where Frame Check Sequence (FCS) Receive (Rx) errors occur randomly when a system is connected to a Dell PowerConnect switch. This driver addresses some link status issues that occur when the networking cable is not plugged in.0 Release Notes o HP Ethernet 1Gb 2-port 332T Adapter HP Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 11 i586 Version: 3.06. This driver addresses some link status issues that occur when the networking cable is not plugged in. HP | Service Pack for ProLiant 2014.134f-2 (Optional) Fixes This driver addresses an issue where Frame Check Sequence (FCS) Receive (Rx) errors occur randomly when a system is connected to a Dell PowerConnect switch.06. This driver addresses an issue that results in the lspci command produces unknown messages in its output.0 385 . This driver addresses an issue which results in a system in S1 sleep mode failing to wake up when it receives a Magic Packet. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o HP NC105i PCIe Gigabit Server Adapter HP NC107i PCIe Quad Port Gigabit Server Adapter HP NC320m PCI Express Gigabit Server Adapter HP NC325m Quad Port PCIe Gigabit Server Adapter HP NC326i PCIe Dual Port Gigabit Server Adapter HP NC326m Dual Port PCIe Gigabit Server Adapter HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331i-SPI Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter HP Ethernet 1Gb 2-port 332T Adapter HP Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 3.HP Service Pack for ProLiant 2014. 06.430.1109 (Optional) Fixes This driver addresses an issue that prevents enumeration of Virtual Functions in an HP Virtual Connect version 4.HP Service Pack for ProLiant 2014. Enhancements The maximum supported transmit queue depth is now 2048.06.10 environment.0 386 .0.0 Release Notes This driver addresses an issue which results in a system in S1 sleep mode failing to wake up when it receives a Magic Packet. Supported Devices and Features These drivers support the following network adapters: o o o o o o o o o o o o o HP NC105i PCIe Gigabit Server Adapter HP NC107i PCIe Quad Port Gigabit Server Adapter HP NC320m PCI Express Gigabit Server Adapter HP NC325m Quad Port PCIe Gigabit Server Adapter HP NC326i PCIe Dual Port Gigabit Server Adapter HP NC326m Dual Port PCIe Gigabit Server Adapter HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331i-SPI Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter HP Ethernet 1Gb 2-port 332T Adapter HP Emulex 10GbE Driver for Windows Server 2008 Version: 10. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP | Service Pack for ProLiant 2014. HP Service Pack for ProLiant 2014.1109 (Optional) Fixes This driver addresses an issue that prevents enumeration of Virtual Functions in an HP Virtual Connect version 4.06.0. Enhancements The maximum supported transmit queue depth is now 2048.430. Supported Devices and Features 387 This driver supports the following HP network adapters: o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP | Service Pack for ProLiant 2014. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP Emulex 10GbE Driver for Windows Server 2008 x64 Editions Version: 10.10 environment.06. Enhancements The maximum supported transmit queue depth is now 2048.0 .10 environment.1109 (Optional) Fixes This driver addresses an issue that prevents enumeration of Virtual Functions in an HP Virtual Connect version 4.0.0 Release Notes o HP FlexFabric 10Gb 2-port 554M Adapter HP Emulex 10GbE Driver for Windows Server 2008 R2 Version: 10.430. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter 388 HP Emulex 10GbE Driver for Windows Server 2012 R2 Version: 10. Enhancements The maximum supported transmit queue depth is now 2048.0.430.0 .10 environment.06.0.HP Service Pack for ProLiant 2014.430.1109 (Optional) HP | Service Pack for ProLiant 2014.0 Release Notes o o o o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP Emulex 10GbE Driver for Windows Server 2012 Version: 10.1109 (Optional) Fixes This driver addresses an issue that prevents enumeration of Virtual Functions connections in an HP Virtual Connect version 4.06. This driver addresses an issue that results in an incorrect maximum number of Virtual Functions being displayed in certain situations. 0 389 .HP Service Pack for ProLiant 2014.1-1 (Optional) Fixes This driver addresses an issue where the NIC adapter fails to initialize after a suspend-resume cycle.10 environment. This driver addresses an issue where the virtual function interfaces assigned to the virtual machine lose the MAC address after the virtual machine is rebooted.06.0 Release Notes Fixes This driver addresses an issue that prevents enumeration of Virtual Functions connections in an HP Virtual Connect version 4.06.9. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP | Service Pack for ProLiant 2014.311. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP Emulex 10GbE Drivers for Red Hat Enterprise Linux 5 i686 Version: 4. Enhancements The maximum supported transmit queue depth is now 2048. 9. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE Drivers for Red Hat Enterprise Linux 6 i686 Version: 4.06.9.0 Release Notes o o o o o HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 4.0 .311. 390 Supported Devices and Features This driver supports the following HP network adapters: HP | Service Pack for ProLiant 2014.311.1-1 (Optional) Fixes This driver addresses an issue where the NIC adapter fails to initialize after a suspend-resume cycle.HP Service Pack for ProLiant 2014.06. This driver addresses an issue where the virtual function interfaces assigned to the virtual machine lose the MAC address after the virtual machine is rebooted.1-1 (Optional) Fixes This driver addresses an issue where the NIC adapter fails to initialize after a suspend-resume cycle. This driver addresses an issue where the virtual function interfaces assigned to the virtual machine lose the MAC address after the virtual machine is rebooted. HP Service Pack for ProLiant 2014.9.06.0 391 .0 Release Notes o o o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 4.311.1-1 (Optional) Fixes HP | Service Pack for ProLiant 2014.311. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE Drivers for SUSE Linux Enterprise Server 11 i586 Version: 4.06.9.1-1 (Optional) Fixes This driver addresses an issue where the NIC adapter fails to initialize after a suspend-resume cycle. This driver addresses an issue where the virtual function interfaces assigned to the virtual machine lose the MAC address after the virtual machine is rebooted. 0 392 . This driver addresses an issue where the virtual function interfaces assigned to the virtual machine lose the MAC address after the virtual machine is rebooted. This driver addresses an issue where the virtual function interfaces assigned to the virtual machine lose the MAC address after the virtual machine is rebooted.9. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP | Service Pack for ProLiant 2014.1-1 (Optional) Fixes This driver addresses an issue where the NIC adapter fails to initialize after a suspend-resume cycle.311. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o o o o o o HP NC550SFP Dual Port 10GbE Server Adapter HP NC550m Dual Port Flex-10 10GbE BL-c Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC552m 10Gb 2-port Flex-10 Server Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 4.06.HP Service Pack for ProLiant 2014.0 Release Notes This driver addresses an issue where the NIC adapter fails to initialize after a suspend-resume cycle.06. HP Service Pack for ProLiant 2014.160.06.0 Release Notes o o HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE iSCSI Driver for Windows Server 2008 Version: 4.0 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver.9.0.430.06. versioned 10.0.1109. versioned 10.0 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver.9.160. Supported Devices and Features This driver supports the following HP iSCSI adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP | Service Pack for ProLiant 2014.0 393 .1109. Supported Devices and Features This driver supports the following HP Emulex iSCSI adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP Emulex 10GbE iSCSI Driver for Windows Server 2008 R2 Version: 4.430. 9. Supported Devices and Features This driver supports the following HP iSCSI adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter 394 HP Emulex 10GbE iSCSI Driver for Windows Server 2012 R2 Version: 4.160.0 Release Notes HP Emulex 10GbE iSCSI Driver for Windows Server 2008 x64 Editions Version: 4.0.0 .06.0 (Optional) HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.9.1109.0 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver.160. versioned 10.430.0.9. versioned 10.1109. Supported Devices and Features This driver supports the following HP iSCSI adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP Emulex 10GbE iSCSI Driver for Windows Server 2012 Version: 4.160.0 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver.430.06. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE iSCSI Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 4.196.06.1-1.1007-1 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver versioned 4.HP Service Pack for ProLiant 2014.9.9.311.0 395 .0 Release Notes Enhancements Initial release. Supported Devices and Features HP | Service Pack for ProLiant 2014.06.196.9.9.311.1007-1 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver versioned 4. Supported Devices and Features This driver supports the following HP iSCSI adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP CN1000E Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP Emulex 10GbE iSCSI Drivers for Red Hat Enterprise Linux 5 i686 Version: 4.1-1. 4-1 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver versioned 4.HP Service Pack for ProLiant 2014.9.311.06.4-1 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver versioned 4.1-1.9. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE iSCSI Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 4.1-1.0 . Supported Devices and Features 396 This driver supports the following HP network adapters: o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP | Service Pack for ProLiant 2014.9.311.9.06.311.311.0 Release Notes This driver supports the following HP network adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE iSCSI Drivers for Red Hat Enterprise Linux 6 i686 Version: 4. 9.1-1.311.HP Service Pack for ProLiant 2014.9. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE iSCSI Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 4.06.4-1 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver versioned 4.311.9.311.0 Release Notes o o o o o o o o HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Emulex 10GbE iSCSI Drivers for SUSE Linux Enterprise Server 11 i586 Version: 4. Supported Devices and Features This driver supports the following HP network adapters: o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP | Service Pack for ProLiant 2014.1-1.4-1 (Optional) Enhancements This driver has been updated by Emulex for use with the corresponding Emulex 10Gb Ethernet Driver versioned 4.311.06.0 397 .9. HP Service Pack for ProLiant 2014. This driver addresses several Runtime Power Management (RPM) issues. This driver addresses an issue where an Asynchronous Transfer Mode (ATM) connection drops after driver unload if large Maximum Transmission Unit (MTU) is configured. It also allows ULP mode to be enabled in sleep mode 0 (S0) when Runtime Power Management (RPM) is enabled.06. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP NC112i 1-port Ethernet Server Adapter HP NC112T PCI Express Gigabit Server Adapter HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP Intel e1000e Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 2.0 Release Notes o o o HP FlexFabric 10Gb 2-port 554M Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Converged Network Adapter HP Intel e1000e Drivers for Red Hat Enterprise Linux 5 i686 Version: 2.5. HP | Service Pack for ProLiant 2014.10 and above. This driver addresses some Virtual Local Area Network (VLAN) support issues for kernels versioned 3.7-4 (Optional) Fixes This driver addresses a system panic that occurs with Receive (Rx) traffic while the interface is going down.0 .5. This driver addresses low throughput and high Cyclic Redundancy Check (CRC) error count issues when using 4k jumbo MTU.7-4 (Optional) Fixes 398 This driver addresses a system panic that occurs with Receive (Rx) traffic while the interface is going down.06. Enhancements This driver now allows the l218 chipset Ultra-Low Power (ULP) mode to be enabled in sleep modes 3 and 4 (S3/4). This driver addresses several Runtime Power Management (RPM) issues. 06. It also allows ULP mode to be enabled in sleep mode 0 (S0) when Runtime Power Management (RPM) is enabled. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP NC112i 1-port Ethernet Server Adapter HP NC112T PCI Express Gigabit Server Adapter HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP Intel e1000e Drivers for Red Hat Enterprise Linux 6 i686 Version: 2. It also allows ULP mode to be enabled in sleep mode 0 (S0) when Runtime Power Management (RPM) is enabled.06.10 and above.5. This driver addresses an issue where an Asynchronous Transfer Mode (ATM) connection drops after driver unload if large Maximum Transmission Unit (MTU) is configured. This driver addresses several Runtime Power Management (RPM) issues. HP | Service Pack for ProLiant 2014.7-4 (Optional) Fixes This driver addresses a system panic that occurs with Receive (Rx) traffic while the interface is going down. This driver addresses low throughput and high Cyclic Redundancy Check (CRC) error count issues when using 4k jumbo MTU.HP Service Pack for ProLiant 2014.10 and above. This driver addresses some Virtual Local Area Network (VLAN) support issues for kernels versioned 3.0 399 .0 Release Notes This driver addresses an issue where an Asynchronous Transfer Mode (ATM) connection drops after driver unload if large Maximum Transmission Unit (MTU) is configured. This driver addresses low throughput and high Cyclic Redundancy Check (CRC) error count issues when using 4k jumbo MTU. This driver addresses some Virtual Local Area Network (VLAN) support issues for kernels versioned 3. Enhancements This driver now allows the l218 chipset Ultra-Low Power (ULP) mode to be enabled in sleep modes 3 and 4 (S3/4). Enhancements This driver now allows the l218 chipset Ultra-Low Power (ULP) mode to be enabled in sleep modes 3 and 4 (S3/4). 0 400 .10 and above.HP Service Pack for ProLiant 2014. This driver addresses an issue where an Asynchronous Transfer Mode (ATM) connection drops after driver unload if large Maximum Transmission Unit (MTU) is configured. This driver addresses low throughput and high Cyclic Redundancy Check (CRC) error count issues when using 4k jumbo MTU.06. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP NC112i 1-port Ethernet Server Adapter HP NC112T PCI Express Gigabit Server Adapter HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP | Service Pack for ProLiant 2014.0 Release Notes Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP NC112i 1-port Ethernet Server Adapter HP NC112T PCI Express Gigabit Server Adapter HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP Intel e1000e Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 2.7-4 (Optional) Fixes This driver addresses a system panic that occurs with Receive (Rx) traffic while the interface is going down. This driver addresses some Virtual Local Area Network (VLAN) support issues for kernels versioned 3. Enhancements This driver now allows the l218 chipset Ultra-Low Power (ULP) mode to be enabled in sleep modes 3 and 4 (S3/4).5. This driver addresses several Runtime Power Management (RPM) issues.06. It also allows ULP mode to be enabled in sleep mode 0 (S0) when Runtime Power Management (RPM) is enabled. 5. This driver addresses several Runtime Power Management (RPM) issues.5. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP NC112i 1-port Ethernet Server Adapter HP NC112T PCI Express Gigabit Server Adapter HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP Intel e1000e Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 2. This driver addresses low throughput and high Cyclic Redundancy Check (CRC) error count issues when using 4k jumbo MTU. Enhancements This driver now allows the l218 chipset Ultra-Low Power (ULP) mode to be enabled in sleep modes 3 and 4 (S3/4). It also allows ULP mode to be enabled in sleep mode 0 (S0) when Runtime Power Management (RPM) is enabled.06. This driver addresses low throughput and high Cyclic Redundancy Check (CRC) error count issues when HP | Service Pack for ProLiant 2014.7-4 (Optional) Fixes This driver addresses a system panic that occurs with Receive (Rx) traffic while the interface is going down. This driver addresses some Virtual Local Area Network (VLAN) support issues for kernels versioned 3. This driver addresses an issue where an Asynchronous Transfer Mode (ATM) connection drops after driver unload if large Maximum Transmission Unit (MTU) is configured.06.HP Service Pack for ProLiant 2014. This driver addresses an issue where an Asynchronous Transfer Mode (ATM) connection drops after driver unload if large Maximum Transmission Unit (MTU) is configured. This driver addresses several Runtime Power Management (RPM) issues.10 and above.0 Release Notes HP Intel e1000e Drivers for SUSE Linux Enterprise Server 11 i586 Version: 2.7-4 (Optional) Fixes This driver addresses a system panic that occurs with Receive (Rx) traffic while the interface is going down.0 401 . 06.HP Service Pack for ProLiant 2014. Enhancements This driver now supports the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features This driver supports the following HP Intel E1R network adapters: o o o o o o o o o HP NC365T PCI Express Quad Port Gigabit Server Adapter HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP | Service Pack for ProLiant 2014. It also allows ULP mode to be enabled in sleep mode 0 (S0) when Runtime Power Management (RPM) is enabled. Enhancements This driver now allows the l218 chipset Ultra-Low Power (ULP) mode to be enabled in sleep modes 3 and 4 (S3/4).29. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP NC112i 1-port Ethernet Server Adapter HP NC112T PCI Express Gigabit Server Adapter HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP Intel E1R Driver for Windows Server 2008 Version: 12.06.7.0 Release Notes using 4k jumbo MTU.0 (C) (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link. This driver addresses some Virtual Local Area Network (VLAN) support issues for kernels versioned 3.10 and above.0 402 . 06.0 (C) (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link.7.29.7. Enhancements This driver now supports the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features This driver supports the following HP Intel E1R network adapters: o o o o o o o o o o HP NC365T PCI Express Quad Port Gigabit Server Adapter HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Intel E1R Driver for Windows Server 2008 x64 Editions Version: 12.0 .28.06. Enhancements This driver now supports the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter 403 HP | Service Pack for ProLiant 2014.0 Release Notes o Hp Ethernet 1Gb 2-port 367i Adapter HP Intel E1R Driver for Windows Server 2008 R2 Version: 12.HP Service Pack for ProLiant 2014.0 (C) (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link. 0 (C) (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link.06.8.06. Enhancements This driver now supports the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features This driver supports the following HP Intel E1R network adapters: o o o o o o o o o o HP NC365T PCI Express Quad Port Gigabit Server Adapter HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Intel E1R Driver for Windows Server 2012 R2 Version: 12.0 404 .28.26.0 Release Notes Supported Devices and Features This driver supports the following HP Intel E1R network adapters: o o o o o o o o o o HP NC365T PCI Express Quad Port Gigabit Server Adapter HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 2-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter Hp Ethernet 1Gb 2-port 367i Adapter HP Intel E1R Driver for Windows Server 2012 Version: 12.0 (B) (Optional) Fixes HP | Service Pack for ProLiant 2014.7.HP Service Pack for ProLiant 2014. 06.HP Service Pack for ProLiant 2014. Enhancements These drivers now provide receive packet statistics for additional packet types.0 405 .06. These drivers now support the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features These drivers support the following HP Intel network adapters: o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP | Service Pack for ProLiant 2014. Enhancements This driver now supports the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features This driver supports the following HP Intel E1R network adapters: o o o o o o o o o o HP NC365T PCI Express Quad Port Gigabit Server Adapter HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366M Adapter Hp Ethernet 1Gb 2-port 367i Adapter HP Intel igb Drivers for Red Hat Enterprise Linux 5 i686 Version: 5.0 Release Notes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link.0.7-4 (Optional) Fixes These drivers address transmit (Tx) hangs on kernels with Byte Queue Limits (BQL) enabled and Interrupt Throttle Rate (ITR) of less than 100K per second. 06.0 406 .0.0 Release Notes o o o o o o o o HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP NC365T 4-port Ethernet Server Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Intel igb Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 5. Enhancements These drivers now provide receive packet statistics for additional packet types.HP Service Pack for ProLiant 2014.06.0.7-4 (Optional) Fixes These drivers address transmit (Tx) hangs on kernels with Byte Queue Limits (BQL) enabled and Interrupt HP | Service Pack for ProLiant 2014. These drivers now support the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features These drivers support the following HP Intel network adapters: o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP NC365T 4-port Ethernet Server Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Intel igb Drivers for Red Hat Enterprise Linux 6 i686 Version: 5.7-4 (Optional) Fixes These drivers address transmit (Tx) hangs on kernels with Byte Queue Limits (BQL) enabled and Interrupt Throttle Rate (ITR) of less than 100K per second. 0 407 .HP Service Pack for ProLiant 2014.7-4 (Optional) Fixes These drivers address transmit (Tx) hangs on kernels with Byte Queue Limits (BQL) enabled and Interrupt Throttle Rate (ITR) of less than 100K per second.06.0 Release Notes Throttle Rate (ITR) of less than 100K per second. Enhancements These drivers now provide receive packet statistics for additional packet types.06.0. These drivers now support the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features These drivers support the following HP Intel network adapters: o HP Ethernet 1Gb 2-port 361i Adapter HP | Service Pack for ProLiant 2014. These drivers now support the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features These drivers support the following HP Intel network adapters: o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP NC365T 4-port Ethernet Server Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Intel igb Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 5. Enhancements These drivers now provide receive packet statistics for additional packet types. These drivers now support the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features These drivers support the following HP Intel network adapters: o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP NC365T 4-port Ethernet Server Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter 408 HP Intel igb Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 5.0.0 .HP Service Pack for ProLiant 2014.06.7-4 (Optional) Fixes These drivers address transmit (Tx) hangs on kernels with Byte Queue Limits (BQL) enabled and Interrupt Throttle Rate (ITR) of less than 100K per second.0.0 Release Notes o o o o o o o o o o o HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP NC365T 4-port Ethernet Server Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Intel igb Drivers for SUSE Linux Enterprise Server 11 i586 Version: 5. Enhancements These drivers now provide receive packet statistics for additional packet types.7-4 (Optional) HP | Service Pack for ProLiant 2014.06. Enhancements These drivers now provide receive packet statistics for additional packet types. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter 409 HP | Service Pack for ProLiant 2014.46-4 (Optional) Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter.0 .06.0 Release Notes Fixes These drivers address transmit (Tx) hangs on kernels with Byte Queue Limits (BQL) enabled and Interrupt Throttle Rate (ITR) of less than 100K per second.06.HP Service Pack for ProLiant 2014.19. These drivers now support the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter Supported Devices and Features These drivers support the following HP Intel network adapters: o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP NC365T 4-port Ethernet Server Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Intel ixgbe Drivers for Red Hat Enterprise Linux 5 i686 Version: 3.0. Supported Devices and Features HP | Service Pack for ProLiant 2014.0.46-4 (Optional) Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter.19.0 Release Notes HP Intel ixgbe Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 3.HP Service Pack for ProLiant 2014. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbe Drivers for Red Hat Enterprise Linux 6 i686 Version: 3.46-4 (Optional) Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter.0 410 .19.06.46-4 (Optional) Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter.19.0.06. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbe Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 3.0. 46-4 (Optional) Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter. Supported Devices and Features These drivers support the following network adapters: o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter 411 HP | Service Pack for ProLiant 2014.19. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbe Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 3.06.46-4 (Optional) Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter.19.0 Release Notes These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbe Drivers for SUSE Linux Enterprise Server 11 i586 Version: 3.0.0.06.0 .HP Service Pack for ProLiant 2014. 12.0.9 guest operating system.38-4 (Optional) Fixes These drivers no longer hang when the “rmmod” command is executed on a RHEL 5. Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter. These drivers now provide support for Busy Poll Sockets.0 Release Notes o HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbevf Drivers for Red Hat Enterprise Linux 5 i686 Version: 2.0 . Supported Devices and Features These drivers support the following network adapters: o o o o o 412 HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP | Service Pack for ProLiant 2014. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbevf Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 2. Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter.06. These drivers now provide support for Busy Poll Sockets.9 guest operating system.06.12.HP Service Pack for ProLiant 2014.38-4 (Optional) Fixes These drivers no longer hang when the “rmmod” command is executed on a RHEL 5.0. 0. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter 413 HP | Service Pack for ProLiant 2014.0 Release Notes o o HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbevf Drivers for Red Hat Enterprise Linux 6 i686 Version: 2. These drivers now provide support for Busy Poll Sockets.38-4 (Optional) Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter.0 .12.0.12. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbevf Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 2.06.HP Service Pack for ProLiant 2014.38-4 (Optional) Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter. These drivers now provide support for Busy Poll Sockets.06. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixgbevf Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 2.0 Release Notes HP Intel ixgbevf Drivers for SUSE Linux Enterprise Server 11 i586 Version: 2.HP Service Pack for ProLiant 2014.0.38-4 (Optional) Fixes These drivers address an issue where a guest virtual machine on SLES11 SP2 is unable to change the hardware offload settings for the VF interface.0 .12.0. Supported Devices and Features These drivers support the following network adapters: o o o o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter 414 HP | Service Pack for ProLiant 2014.38-4 (Optional) Fixes These drivers address an issue where a guest virtual machine on SLES11 SP2 is unable to change the hardware offload settings for the VF interface. Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter. These drivers now provide support for Busy Poll Sockets. Enhancements These drivers now support the HP Ethernet 10Gb 2-port 562i Adapter.06.12. These drivers now provide support for Busy Poll Sockets.06. 5.0 (D) (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link.24. Supported Devices and Features This component supports the following HP Intel ixn network adapters: o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter This component supports the following HP Intel ixt network adapters: o o o HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixn/ixt Drivers for Windows Server 2008 R2 Version: 3. Supported Devices and Features This component supports the following HP Intel ixn network adapters: o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter 415 This component supports the following HP Intel ixt network adapters: HP | Service Pack for ProLiant 2014. Enhancements This component now supports the HP Ethernet 10Gb 2-port 562i Adapter. Enhancements This component now supports the HP Ethernet 10Gb 2-port 562i Adapter.0 .22.HP Service Pack for ProLiant 2014.0 Release Notes HP Intel ixn/ixt Drivers for Windows Server 2008 Version: 3.0 (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link.06.06.7. HP Service Pack for ProLiant 2014.06.0 Release Notes o o o HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixn/ixt Drivers for Windows Server 2008 x64 Editions Version: 3.5.22.0 (D) (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link. Enhancements This component now supports the HP Ethernet 10Gb 2-port 562i Adapter. Supported Devices and Features This component supports the following HP Intel ixn network adapters: o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter This component supports the following HP Intel ixt network adapters: o o o HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixn/ixt Drivers for Windows Server 2012 Version: 3.7.24.0 (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link. Enhancements This component now supports the HP Ethernet 10Gb 2-port 562i Adapter. Supported Devices and Features This component supports the following HP Intel ixn network adapters: o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP | Service Pack for ProLiant 2014.06.0 416 HP Service Pack for ProLiant 2014.06.0 Release Notes o HP Ethernet 10Gb 2-port 560M Adapter This component supports the following HP Intel ixt network adapters: o o o HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel ixn/ixt Drivers for Windows Server 2012 R2 Version: 3.7.24.0 (Optional) Fixes This driver addresses an issue where a “link down” message is recorded in the Windows system event log during every system boot regardless of the actual state of the link. Enhancements This component now supports the HP Ethernet 10Gb 2-port 562i Adapter. Supported Devices and Features This component supports the following HP Intel ixn network adapters: o o o o HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter This component supports the following HP Intel ixt network adapters: o o o HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Mellanox 10GbE Driver for Windows Server 2008 Version: 2.2.5.9196 (Optional) Fixes This driver corrects an issue where a system running in a Virtual Connection Environment automatically went into recovery mode after the driver was installed and the system rebooted. Supported Devices and Features 417 This driver supports the following HP Mellanox 10GbE network adapters: o HP 10GbE Dual Port Mezzanine Network Interface Card HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes o o o HP NC542m Dual Port Flex-10 10GbE BL-c Adapter HP NC543i 1-port 4x QDR IB/Flex-10 10Gb Adapter HP NC543i 2-port 4x QDR IB/10Gb Adapter HP Mellanox 10GbE Driver for Windows Server 2008 R2. Version: 2.2.5.9196 (Optional) Fixes This driver corrects an issue where a system running in a Virtual Connection Environment automatically went into recovery mode after the driver was installed and the system rebooted. Supported Devices and Features This driver supports the following HP Mellanox 10GbE network adapters: o o o o HP 10GbE Dual Port Mezzanine Network Interface Card HP NC542m Dual Port Flex-10 10GbE BL-c Adapter HP NC543i 1-port 4x QDR IB/Flex-10 10Gb Adapter HP NC543i 2-port 4x QDR IB/10Gb Adapter HP Mellanox 10GbE Driver for Windows Server 2008 x64 Editions Version: 2.2.5.9196 (Optional) Fixes This driver corrects an issue where a system running in a Virtual Connection Environment automatically went into recovery mode after the driver was installed and the system rebooted. Supported Devices and Features This driver supports the following HP Mellanox 10GbE network adapters: o o o o HP 10GbE Dual Port Mezzanine Network Interface Card HP NC542m Dual Port Flex-10 10GbE BL-c Adapter HP NC543i 1-port 4x QDR IB/Flex-10 10Gb Adapter HP NC543i 2-port 4x QDR IB/10Gb Adapter HP Mellanox EN Driver for InfiniBand adapters (Red Hat Enterprise Linux 5 Update 10 i686) Version: 1.5.10 (Recommended) 418 Fixes Fixes in Version 1.5.10 HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes o o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Version 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss Enhancements Changes in Version 1.5.10 from 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 Update 10 (x86) supported by this binary rpm are: 2.6.18-371.el5 - (x86) and future update kernels. 2.6.18-371.el5xen - (x86) and future update kernels. 2.6.18-371.el5PAE - (x86) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (Red Hat Enterprise Linux 5 Update 10 x86_64) Version: 1.5.10 (Recommended) Fixes Fixes in Version 1.5.10 o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) HP | Service Pack for ProLiant 2014.06.0 419 HP Service Pack for ProLiant 2014.06.0 Release Notes o no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Version 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss Enhancements Changes in Version 1.5.10 from 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 Update 10 (x86_64) supported by this binary rpm are: 2.6.18-371.el5 - (x86_64) and future update kernels. 2.6.18-371.el5xen - (x86_64) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (Red Hat Enterprise Linux 5 Update 9 i686) Version: 1.5.10 (Recommended) Fixes Fixes in Version 1.5.10 o o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Version 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss HP | Service Pack for ProLiant 2014.06.0 420 HP Service Pack for ProLiant 2014.06.0 Release Notes Enhancements Changes in Version 1.5.10 from 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 Update 9 (x86) supported by this binary rpm are: 2.6.18-348.el5 - (x86) and future update kernels. 2.6.18-348.el5xen - (x86) and future update kernels. 2.6.18-348.el5PAE - (x86) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (Red Hat Enterprise Linux 5 Update 9 x86_64) Version: 1.5.10 (Recommended) Fixes Fixes in Version 1.5.10 o o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Version 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss Enhancements Changes in Version 1.5.10 from 1.5.9 o Fixes only. 421 Changes in Version 1.5.9 from 1.5.8.3 o Added support to kernel.org 3.5. HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes o Improved latency by optimizing RX repost mechanism. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 Update 9 (x86_64) supported by this binary rpm are: 2.6.18-348.el5 - (x86_64) and future update kernels. 2.6.18-348.el5xen - (x86_64) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (Red Hat Enterprise Linux 6 Update 4 x86) Version: 2.0 (Recommended) Fixes Fixes in version 2.0-3.0.0: o o o o Fixed TX timeout issues. Fixed Ethtool status report for Virtual Functions. Fixed an issue of VLAN traffic over Virtual Machine in paravirtualized mode. Fixed Ethtool operation crash while interface down. Fixes in version 1.5.10 o o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Rev 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss Enhancements Changes in version 2.0-3.0.0 From version 1.5.10 o o Added support for SuSE Linux Enterprise Server 11 SP3. Added ConnectX-3 Pro support. Changes in version 1.5.10 From version 1.5.9 HP | Service Pack for ProLiant 2014.06.0 422 HP Service Pack for ProLiant 2014.06.0 Release Notes o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6U4 (x86) supported by this binary rpm are: 2.6.32-358.el6 - (x86) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (Red Hat Enterprise Linux 6 Update 4 x86_64) Version: 2.0 (Recommended) Fixes Fixes in version 2.0-3.0.0: o o o o Fixed TX timeout issues. Fixed Ethtool status report for Virtual Functions. Fixed an issue of VLAN traffic over Virtual Machine in paravirtualized mode. Fixed Ethtool operation crash while interface down. Fixes in version 1.5.10 o o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Rev 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss 423 Enhancements Changes in version 2.0-3.0.0 From version 1.5.10 HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes o o Added support for SuSE Linux Enterprise Server 11 SP3. Added ConnectX-3 Pro support. Changes in version 1.5.10 From version 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6U4 (x86_64) supported by this binary rpm are: 2.6.32-358.el6 - (x86_64) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (Red Hat Enterprise Linux 6 Update 5 x86) Version: 2.1 (Recommended) Fixes Fixes in version 2.1: o o o o Fixed TX timeout issues. Fixed Ethtool status report for Virtual Functions. Fixed an issue of VLAN traffic over Virtual Machine in paravirtualized mode. Fixed Ethtool operation crash while interface down. Fixes in version 1.5.10 o o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. 424 Fixes in Rev 1.5.9 o Fixed bad TX completion notification request logic, could lead to TX timeout. HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes o Fixed PowerPC connectivity loss Enhancements Changes in version 2.1 From version 1.5.10 o o Added support for SuSE Linux Enterprise Server 11 SP3. Added ConnectX-3 Pro support. Changes in version 1.5.10 From version 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6U5 (x86) supported by this binary rpm are: 2.6.32-431.el6 - (x86) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (Red Hat Enterprise Linux 6 Update 5 x86_64) Version: 2.1 (Recommended) Fixes Fixes in version 2.1: o o o o Fixed TX timeout issues. Fixed Ethtool status report for Virtual Functions. Fixed an issue of VLAN traffic over Virtual Machine in paravirtualized mode. Fixed Ethtool operation crash while interface down. Fixes in version 1.5.10 o o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. HP | Service Pack for ProLiant 2014.06.0 425 HP Service Pack for ProLiant 2014.06.0 Release Notes Fixes in Rev 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss Enhancements Changes in version 2.1 From version 1.5.10 o o Added support for SuSE Linux Enterprise Server 11 SP3. Added ConnectX-3 Pro support. Changes in version 1.5.10 From version 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6U5 (x86_64) supported by this binary rpm are: 2.6.32-431.el6 - (x86_64) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (SUSE LINUX Enterprise Server 11 SP2 AMD64/EM64T) Version: 2.0 (Recommended) Fixes Fixes in version 2.0-3.0.0: o o o o Fixed TX timeout issues. Fixed Ethtool status report for Virtual Functions. Fixed an issue of VLAN traffic over Virtual Machine in paravirtualized mode. Fixed Ethtool operation crash while interface down. Fixes in version 1.5.10 o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) HP | Service Pack for ProLiant 2014.06.0 426 HP Service Pack for ProLiant 2014.06.0 Release Notes o no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Rev 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss Enhancements Changes in version 2.0-3.0.0 From version 1.5.10 o o Added support for SuSE Linux Enterprise Server 11 SP3. Added ConnectX-3 Pro support. Changes in version 1.5.10 From version 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server SP2 (AMD64/EM64T) supported by this binary rpm are: 3.0.13-0.27-default - (AMD64/EM64T) and future update kernels. 3.0.13-0.27-xen - (AMD64/EM64T) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (SUSE LINUX Enterprise Server 11 SP2 x86) Version: 2.0 (Recommended) Fixes Fixes in version 2.0-3.0.0: o o o o Fixed TX timeout issues. Fixed Ethtool status report for Virtual Functions. Fixed an issue of VLAN traffic over Virtual Machine in paravirtualized mode. Fixed Ethtool operation crash while interface down. Fixes in version 1.5.10 o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. HP | Service Pack for ProLiant 2014.06.0 427 HP Service Pack for ProLiant 2014.06.0 Release Notes o o o o o o o Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Rev 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss Enhancements Changes in version 2.0-3.0.0 From version 1.5.10 o o Added support for SuSE Linux Enterprise Server 11 SP3. Added ConnectX-3 Pro support. Changes in version 1.5.10 From version 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server SP2 (x86) supported by this binary rpm are: 3.0.13-0.27-default - (x86) and future update kernels. 3.0.13-0.27-xen - (x86) and future update kernels. 3.0.13-0.27-pae - (x86) and future update kernels. HP Mellanox EN Driver for InfiniBand adapters (SUSE LINUX Enterprise Server 11 SP3 AMD64/EM64T) Version: 2.0 (Recommended) 428 Fixes Fixes in version 2.0-3.0.0: o Fixed TX timeout issues. HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes o o o Fixed Ethtool status report for Virtual Functions. Fixed an issue of VLAN traffic over Virtual Machine in paravirtualized mode. Fixed Ethtool operation crash while interface down. Fixes in version 1.5.10 o o o o o o o o Driver no longer unloads after installation. Currently, the driver is reloaded after installation. Configuration files are no longer modified during driver installation. MTU size calculation now results in correct value. Race condition no longer exists in join/leave multicast group flow. Restored RX buffer pointer in case of failure. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists. Loss of connectivity issue for iperf long run is resolved. Fixes in Rev 1.5.9 o o Fixed bad TX completion notification request logic, could lead to TX timeout. Fixed PowerPC connectivity loss Enhancements Changes in version 2.0-3.0.0 From version 1.5.10 o o Added support for SuSE Linux Enterprise Server 11 SP3. Added ConnectX-3 Pro support. Changes in version 1.5.10 From version 1.5.9 o Fixes only. Changes in Version 1.5.9 from 1.5.8.3 o o Added support to kernel.org 3.5. Improved latency by optimizing RX repost mechanism Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server SP3 (AMD64/EM64T) supported by this binary rpm are: 3.0.76-0.11-default - (AMD64/EM64T) and future update kernels. 3.0.76-0.11-xen - (AMD64/EM64T) and future update kernels. 429 HP | Service Pack for ProLiant 2014.06.0 9 o Fixes only. Fixes in Rev 1. Fixed PowerPC connectivity loss Enhancements Changes in version 2. Configuration files are no longer modified during driver installation. Race condition no longer exists in join/leave multicast group flow.0. Loss of connectivity issue for iperf long run is resolved.9 from 1. MTU size calculation now results in correct value.3 o o Added support to kernel. Restored RX buffer pointer in case of failure.5.5. could lead to TX timeout.0.10 o o Added support for SuSE Linux Enterprise Server 11 SP3.5.06.5.0: o o o o Fixed TX timeout issues.HP Service Pack for ProLiant 2014.0-3.5.0 (Recommended) Fixes Fixes in version 2. Fixed Ethtool status report for Virtual Functions. Fixed Ethtool operation crash while interface down.0 430 .0 Release Notes HP Mellanox EN Driver for InfiniBand adapters (SUSE LINUX Enterprise Server 11 SP3 x86) Version: 2. Fixed completely broken IPMI Traffic stops including ping does not pass after several hours of line rate traffic (BlueFlame race) no longer exists.0-3.5.9 o o Fixed bad TX completion notification request logic. Improved latency by optimizing RX repost mechanism Supported Devices and Features SUPPORTED KERNELS: HP | Service Pack for ProLiant 2014. Changes in version 1.06. Added ConnectX-3 Pro support.5. the driver is reloaded after installation.0 From version 1.10 o o o o o o o o Driver no longer unloads after installation.8.org 3.10 From version 1. Fixed an issue of VLAN traffic over Virtual Machine in paravirtualized mode. Changes in Version 1. Currently. Fixes in version 1.5. 11-pae .HP Service Pack for ProLiant 2014.15.0 (B) (Optional) Enhancements This driver now supports Windows Server 2012.17.(x86) and future update kernels.0 .11-default .(x86) and future update kernels.76-0.76-0. 3.0 Release Notes The kernels of SUSE LINUX Enterprise Server SP3 (x86) supported by this binary rpm are: 3. 3.76-0.11-xen . Supported Devices and Features This driver supports the following HP NC-Series Intel network adapters: o o o o o HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP NC-Series Intel E1E Driver for Windows Server 2008 R2 Version: 9.(x86) and future update kernels. HP NC-Series Intel E1E Driver for Windows Server 2008 Version: 9.0 (Optional) Fixes This driver addresses an issue where checksum offload computations were performed even when checksum offload was disabled.06.15. HP | Service Pack for ProLiant 2014.17.0.06.15.0 (Optional) 431 Fixes This driver addresses an issue where checksum offload computations were performed even when checksum offload was disabled.0. Supported Devices and Features This driver supports the following HP NC-Series Intel network adapters: o o o o o HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP NC-Series Intel E1E Driver for Windows Server 2008 x64 Editions Version: 9.0.17. 0 .29.0 (B) (Optional) Fixes This component addresses an issue which can result in installed adapters remaining in a disabled state when they should be enabled after installation is complete. Supported Devices and Features This driver supports the following HP NC-Series Intel E1Q network adapters: o o o o HP NC112T PCI Express Gigabit Server Adapter HP NC112i 1-port Ethernet Server Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP NC-Series Intel E1Q Driver for Windows Server 2008 R2 Version: 12.7.0 (B) (Optional) HP | Service Pack for ProLiant 2014.7.29. Supported Devices and Features This driver supports the following HP NC-Series Intel E1Q network adapters: o o o o HP NC112T PCI Express Gigabit Server Adapter HP NC112i 1-port Ethernet Server Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter 432 HP NC-Series Intel E1Q Driver for Windows Server 2008 x64 Editions Version: 12.HP Service Pack for ProLiant 2014.0 (B) (Optional) Fixes This component addresses an issue which can result in installed adapters remaining in a disabled state when they should be enabled after installation is complete.27.7.0 Release Notes Supported Devices and Features This driver supports the following HP NC-Series Intel network adapters: o o o o o HP NC110T PCI Express Single Port Gigabit Server Adapter HP NC360m Dual Port Gigabit Ethernet BL-c Adapter HP NC360T PCI Express Dual Port Gigabit Server Adapter HP NC364m Quad Port Gigabit Ethernet BL-c Adapter HP NC364T PCI Express Quad Port Gigabit Server Adapter HP NC-Series Intel E1Q Driver for Windows Server 2008 Version: 12.06.06. 0.7.90.0.0 (B) (Optional) Fixes This component addresses an issue which can result in installed adapters remaining in a disabled state when they should be enabled after installation is complete.27.0 .06.06.0 (Optional) Enhancements This software now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP Network Configuration Utility for Windows Server 2008 R2 Version: 10.0 Release Notes Fixes This component addresses an issue which can result in installed adapters remaining in a disabled state when they should be enabled after installation is complete.0 (Optional) Enhancements This software now supports the following network adapters: o 433 HP FlexFabric 20Gb 2-port 630FLB Adapter HP | Service Pack for ProLiant 2014. Supported Devices and Features This driver supports the following HP NC-Series Intel E1Q network adapters: o o o o HP NC112T PCI Express Gigabit Server Adapter HP NC112i 1-port Ethernet Server Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP Network Configuration Utility for Windows Server 2008 Version: 10. Supported Devices and Features This driver supports the following HP NC-Series Intel E1Q network adapters: o o o o HP NC112T PCI Express Gigabit Server Adapter HP NC112i 1-port Ethernet Server Adapter HP NC362i Integrated Dual Port Gigabit Server Adapter HP NC362i Integrated Dual Port BL-c Gigabit Server Adapter HP NC-Series Intel E1Q Driver for Windows Server 2012 Version: 12.90.HP Service Pack for ProLiant 2014. 0 (Optional) Enhancements This software now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP QLogic iSCSI Drivers for Red Hat Enterprise Linux 5 i686 Version: 5.03.03.11-3 (Optional) Enhancements These drivers now support Red Hat Enterprise Linux 5 Update 10.01.0. Supported Devices and Features This software supports the following HP P3P network adapters: o o HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic iSCSI Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 5.90.01.HP Service Pack for ProLiant 2014.11-3 (Optional) Enhancements HP | Service Pack for ProLiant 2014. Supported Devices and Features This software supports the following HP P3P network adapters: o o HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic iSCSI Drivers for Red Hat Enterprise Linux 6 i686 Version: 5.06.0 434 .0 Release Notes o HP FlexFabric 20Gb 2-port 630M Adapter HP Network Configuration Utility for Windows Server 2008 x64 Editions Version: 10.03.11-3 (Optional) Enhancements These drivers now support Red Hat Enterprise Linux 5 Update 10.06.01. 06.01.06.03.01.0 435 .03. Only the packaging has been updated. Supported Devices and Features This software supports the following HP P3P network adapters: o o HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic iSCSI Drivers for SUSE Linux Enterprise Server 11 i586 Version: 5.11-3 (Optional) Enhancements This package has no driver changes.0 Release Notes These drivers now support Red Hat Enterprise Linux 6 Update 5.11-3 (Optional) Enhancements This package has no driver changes.03. Supported Devices and Features HP | Service Pack for ProLiant 2014. Supported Devices and Features This software supports the following HP P3P network adapters: o o HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic iSCSI Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 5.HP Service Pack for ProLiant 2014. Supported Devices and Features This software supports the following HP P3P network adapters: o o HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic iSCSI Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 5.01.11-3 (Optional) Enhancements These drivers now support Red Hat Enterprise Linux 6 Update 5. Only the packaging has been updated. 0 Release Notes This software supports the following HP P3P network adapters: o o HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic nx_nic Drivers for Red Hat Enterprise Linux 5 i686 Version: 4. Supported Devices and Features This software supports the following HP P2 network adapters: o o o HP NC512m Dual Port 10GbE Multifunction BL-c Adapter HP NC510C PCIe 10 Gigabit Server Adapter HP NC510F PCIe 10 Gigabit Server Adapter This software supports the following HP P3 network adapters: o o o o o HP NC522SFP Dual Port 10GbE Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic nx_nic Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 4.0.06.593-1 (Optional) Fixes These drivers no longer hang or panic the system when being unloaded while Input/Output Memory Management Unit (IOMMU) is enabled.06.HP Service Pack for ProLiant 2014. Supported Devices and Features This software supports the following HP P2 network adapters: o o o HP NC512m Dual Port 10GbE Multifunction BL-c Adapter HP NC510C PCIe 10 Gigabit Server Adapter HP NC510F PCIe 10 Gigabit Server Adapter HP | Service Pack for ProLiant 2014.593-1 (Optional) Fixes These drivers no longer hang or panic the system when being unloaded while Input/Output Memory Management Unit (IOMMU) is enabled.0 436 .0. 06.593-1 (Optional) Fixes These drivers no longer hang or panic the system when being unloaded while Input/Output Memory Management Unit (IOMMU) is enabled. Supported Devices and Features This software supports the following HP P2 network adapters: o o 437 HP NC512m Dual Port 10GbE Multifunction BL-c Adapter HP NC510C PCIe 10 Gigabit Server Adapter HP | Service Pack for ProLiant 2014.0 .HP Service Pack for ProLiant 2014.593-1 (Optional) Fixes These drivers no longer hang or panic the system when being unloaded while Input/Output Memory Management Unit (IOMMU) is enabled.06.0 Release Notes This software supports the following HP P3 network adapters: o o o o o HP NC522SFP Dual Port 10GbE Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic nx_nic Drivers for Red Hat Enterprise Linux 6 i686 Version: 4.0.0. Supported Devices and Features This software supports the following HP P2 network adapters: o o o HP NC512m Dual Port 10GbE Multifunction BL-c Adapter HP NC510C PCIe 10 Gigabit Server Adapter HP NC510F PCIe 10 Gigabit Server Adapter This software supports the following HP P3 network adapters: o o o o o HP NC522SFP Dual Port 10GbE Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic nx_nic Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 4. 593-1 (Optional) Fixes These drivers now install correctly on SLES11 SP3.06.0 Release Notes o HP NC510F PCIe 10 Gigabit Server Adapter This software supports the following HP P3 network adapters: o o o o o HP NC522SFP Dual Port 10GbE Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic nx_nic Drivers for SUSE Linux Enterprise Server 11 i586 Version: 4.593-1 (Optional) Fixes These drivers now install correctly on SLES11 SP3. Supported Devices and Features This software supports the following HP P2 network adapters: o o o HP NC512m Dual Port 10GbE Multifunction BL-c Adapter HP NC510C PCIe 10 Gigabit Server Adapter HP NC510F PCIe 10 Gigabit Server Adapter This software supports the following HP P3 network adapters: o o o o o HP NC522SFP Dual Port 10GbE Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic nx_nic Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 4.0 .06. HP | Service Pack for ProLiant 2014. These drivers no longer hang or panic the system when being unloaded while Input/Output Memory Management Unit (IOMMU) is enabled.0. 438 These drivers no longer hang or panic the system when being unloaded while Input/Output Memory Management Unit (IOMMU) is enabled.HP Service Pack for ProLiant 2014.0. Supported Devices and Features This driver supports the following HP P3P network adapters: o o HP CN1000Q Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP QLogic P3P iSCSI Driver for Windows Server 2008 x64 Editions Version: 2. Supported Devices and Features This driver supports the following HP P3P network adapters: o o HP CN1000Q Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter 439 HP | Service Pack for ProLiant 2014.38 (B) (Optional) Fixes This component addresses an issue which can result in installed adapters remaining in a disabled state when they should be enabled after installation is complete.1.HP Service Pack for ProLiant 2014.06.0 Release Notes Supported Devices and Features This software supports the following HP P2 network adapters: o o o HP NC512m Dual Port 10GbE Multifunction BL-c Adapter HP NC510C PCIe 10 Gigabit Server Adapter HP NC510F PCIe 10 Gigabit Server Adapter This software supports the following HP P3 network adapters: o o o o o HP NC522SFP Dual Port 10GbE Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic P3P iSCSI Driver for Windows Server 2008 Version: 2.5.0 .38 (B) (Optional) Fixes This component addresses an issue which can result in installed adapters remaining in a disabled state when they should be enabled after installation is complete.5.06.1. 593.38 (D) (Optional) Enhancements This driver now supports Microsoft Windows Server 2012 R2.1.7. Supported Devices and Features This driver supports the following network adapters: o o HP CN1000Q Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP QLogic P3P Multifunction Driver for Windows Server 2008 Version: 4.06.06.29.1101 (Optional) Enhancements The firmware bundled with this driver has been updated to version 4. Supported Devices and Features This driver supports the following network adapters: o o o o o o o o HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC523SFP 10Gb 2-port Flex-10 Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic P3P Multifunction Driver for Windows Server 2008 R2 Version: 4.5.HP Service Pack for ProLiant 2014.0 . Supported Devices and Features This driver supports the following network adapters: o o o 440 HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP | Service Pack for ProLiant 2014.7.0 Release Notes HP QLogic P3P iSCSI Driver for Windows Server 2012 and Windows Server 2012 R2 Version: 2.29.593.0.0.1101 (Optional) Enhancements The firmware bundled with this driver has been updated to version 4. Supported Devices and Features This driver supports the following network adapters: o o o o o o o HP CN1000Q Dual Port Converged Network Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC523SFP 10Gb 2-port Flex-10 Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter 441 HP QLogic P3P Multifunction Driver for Windows Server 2012 R2 Version: 5.0.0 .HP Service Pack for ProLiant 2014.1101 (Optional) Enhancements The firmware bundled with this driver has been updated to version 4.06.29.1101 (Optional) Enhancements The firmware bundled with this driver has been updated to version 4.7.1101 (Optional) HP | Service Pack for ProLiant 2014.0 Release Notes o o o o o HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC523SFP 10Gb 2-port Flex-10 Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic P3P Multifunction Driver for Windows Server 2008 x64 Editions Version: 4.0. Supported Devices and Features This driver supports the following network adapters: o o o o o o o o HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC523SFP 10Gb 2-port Flex-10 Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic P3P Multifunction Driver for Windows Server 2012 Version: 4.593.29.593.10.3.7.06. 06.29.29. Supported Devices and Features This software supports the following HP P3P network adapters: o o o HP NC523SFP 10Gb 2-port Flex-10 Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP | Service Pack for ProLiant 2014.06.5-3 (Optional) Enhancements These drivers now support Red Hat Enterprise Linux 5 Update 10.0.593.0.0 442 .0 Release Notes Enhancements The firmware bundled with this driver has been updated to version 4.5-3 (Optional) Enhancements These drivers now support Red Hat Enterprise Linux 5 Update 10.0. Supported Devices and Features This software supports the following HP P3P network adapters: o o o HP NC523SFP 10Gb 2-port Flex-10 Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic qlcnic Drivers for Red Hat Enterprise Linux 5 x86_64 Version: 5. Supported Devices and Features This driver supports the following network adapters: o o o o o o o o HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC523SFP 10Gb 2-port Flex-10 Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic qlcnic Drivers for Red Hat Enterprise Linux 5 i686 Version: 5.HP Service Pack for ProLiant 2014. Only the packaging has been updated.5-3 (Optional) Enhancements This package has no driver changes.29.06.0.29.HP Service Pack for ProLiant 2014.5-3 (Optional) Enhancements These drivers now support Red Hat Enterprise Linux 6 Update 5.5-3 (Optional) Enhancements These drivers now support Red Hat Enterprise Linux 6 Update 5.0.29.0 443 .0 Release Notes HP QLogic qlcnic Drivers for Red Hat Enterprise Linux 6 i686 Version: 5. Supported Devices and Features This software supports the following HP P3P network adapters: o o o HP NC523SFP 10Gb 2-port Flex-10 Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic qlcnic Drivers for SUSE Linux Enterprise Server 11 i586 Version: 5.0. Supported Devices and Features This software supports the following HP P3P network adapters: o o o HP NC523SFP 10Gb 2-port Flex-10 Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP | Service Pack for ProLiant 2014.06. Supported Devices and Features This software supports the following HP P3P network adapters: o o o HP NC523SFP 10Gb 2-port Flex-10 Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter HP QLogic qlcnic Drivers for Red Hat Enterprise Linux 6 x86_64 Version: 5. The performance tunning guide helps you to setup the parameters that improves the perfomance of Mellanox VPI cards in Ethernet mode. including licensing terms. you may be subject to Mellanox terms and conditions.0.mellanox.com/. When downloading the Mellanox software or documentation.8.0 Release Notes HP QLogic qlcnic Drivers for SUSE Linux Enterprise Server 11 x86_64 Version: 5. then you must uninstall the HP NC-Series Mellanox 10GbE Driver for Linux prior to installing the Mellanox OFED VPI driver.pdf Prerequisites Note: If the HP NC-Series Mellanox 10GbE Driver for Linux is already installed on the server. "Performance_Tuning_Guide_for_Mellanox_Network_Adapters_v1. If you select a URL that directs you to http://www. o uname -r HP | Service Pack for ProLiant 2014. Certain software including drivers and documents may be available from Mellanox. except that HP may provide a limited warranty for Mellanox software in accordance with the terms and conditions of your purchase of the HP product or solution.mellanox.0-3.com.5-3 (Optional) Enhancements This package has no driver changes.0 (Recommended) Important Note! It is recommended to follow instructions from "Performance_Tuning_Guide_for_Mellanox_Network_Adapters_v1. refer to Chapter 9 of "Mellanox OFED Release notes" available at: http://www. you are then leaving HP.com/ to download Mellanox software or documentation. For a list of known issues with this release.8.mellanox. Supported Devices and Features This software supports the following HP P3P network adapters: o o o HP NC523SFP 10Gb 2-port Flex-10 Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP CN1000Q Dual Port Converged Network Adapter Mellanox InfiniBand and Ethernet Driver for SuSE Linux Enterprise Server 11 SP3 Version: 2.06.com/related-docs/prod_software/Mellanox_OFED_Linux_Release_Notes_2_03_0_0.com/.HP Service Pack for ProLiant 2014.06.pdf" .29. if any. provided on its website or otherwise. if using MLNX_EN (Ethernet driver) from this OFED version.0. HP is not responsible for your use of any software or documents that you download from http://www.pdf" and "mlnx_irq_affinity" scripts are bundled with the driver. Only the packaging has been updated.0 444 .mellanox. Please follow the instructions on http://www. 76-0. If using a modified kernel. MLNX OFED v2. This feature is a ConnectX-3 HCA capability.0-3.0 Release Notes 3. then the kernel number will have changed. (Default) [-t|--tmpdir <local work dir>] [--kmp] [-v|--verbose] Installation guide and user manual are provided in the docs directory of the iso file.iso to build a new iso image or tarball with modified kernel support.0.0-sles11sp3-x86_64. then you need to use "mlnx_add_kernel_support.0-sles11sp3-x86_64.0-sles11sp3-x86_64.gz cd MLNX_OFED_LINUX-2.11-default Note: Verify the kernel number matches exactly to the SuSE Linux Enterprise Server 11 SP3.0.0-2.0. Added support for EoIB (Only on SuSE Linux Enterprise Server 11 SP2 and Red Hat Enterprise Linux 6 Update 2) Modified mlx4_core module parameters to associate configuration values with specific PCI devices identified by their bus/device/function value format Reusing DMA mapped buffers: major performance improvements when IOMMU is enabled Added Port level QoS support for mlx4_en Reduced memory consumption for IPoIB Limited the number TX and RX queues to 16 for IPoIB Default IPoIB mode is set to work in Datagram.0.sh" from MLNX_OFED_LINUX2. except for Connect-IB adapter card which uses IPoIB with Connected mode as default.0 445 .06.0.0 contains the following changes and new features: o o o o o o o o o o o Added support for SuSE Linux Enterprise Server 11 SP3 Added support for Connect-IB adapters Added support for SR-IOV (Single Root I/O Virtualization) Added YUM installation support.iso /mnt cd /mnt/docs Enhancements MLNX OFED v2.0-3. [--make-tgz] Create MLNX_OFED tarball.0-3. If errata patches have been added.HP Service Pack for ProLiant 2014. o o o o tar -zxvf MLNX_OFED_LINUX-2.0.sh -m|--mlnx_ofed <path to MLNX_OFED directory> [--make-iso|-make-tgz] [--make-iso] Create MLNX_OFED ISO image.0-3.5 contains the following changes and new features: o o SR-IOV for both Ethernet and InfiniBand (at Beta level).0-3.06. This image has to be used for MLNX OFED installation on the modified kernel.tar.0-sles11sp3-x86_64 mount -o ro.loop MLNX_OFED_LINUX-2.0. Usage: mlnx_add_kernel_support. RoCE over SR-IOV (at Beta level) HP | Service Pack for ProLiant 2014. 64 (Critical) Fixes Fix for CA referenced below titled “SPP HOT FIX . Raw Eth QPs:  Checksum TX/RX  Flow Steering Errata Kernel upgrade support YUM update support Storage – iSER (iSCSI Extensions for RDMA) at Beta level and SRP (SCSI RDMA Protocol).10.64 (Critical) Fixes Fix for CA referenced below titled “SPP HOT FIX . Flow Steering for Ethernet and InfiniBand.register shared memory  Contiguous pages .0 Release Notes o o o o o o o o o o o o eIPoIB to enable IPoIB in a Para-Virtualized environment (at Alpha level) HPC performance enhancement:  Contiguous pages . This feature is a ConnectX-3 HCA capability. 64bit wide counters (port xmit/recv data/packets unicast/mcast) VERSION query API: library and headers Top Driver .hp.06.www2.www2.06.10.HP ProLiant Servers: HP Dynamic Smart Array B120i/B320i Controllers .hp. This feature is a ConnectX-3 HCA capability.internal memory allocation improvements  Contiguous pages . CQs) Ethernet Performance Enhancements (NUMA Related and others) for 40GigE and 10GigE OFED_VMA integration to a single branch Ethernet Time Stamping (at Beta level).0.HP Service Pack for ProLiant 2014.(at Beta level).control objects (QPs.HP ProLiant Servers: HP Dynamic Smart Array B120i/B320i Controllers .0.0 446 .DRIVER UPGRADE REQUIRED to Ensure That a Drive Array Rebuild Does Not Target an Incorrect Drive and Cause Incorrect Data to Be Written to the Drive” http://h20564.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04141183 HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows 2008 x64 Editions Version: 6.DRIVER UPGRADE REQUIRED to Ensure That a Drive Array Rebuild Does Not Target an Incorrect Drive and Cause Incorrect Data to Be Written to the Drive” http://h20564.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04141183 HP | Service Pack for ProLiant 2014.Storage HP ProLiant Dynamic Smart Array RAID Controller Driver for Microsoft Windows Server 2012 and Microsoft Windows 2012 R2 x64 Editions Version: 62. 18.32 (A) (Optional) Important Note! If the target controller was successfully updated to version 6.18.0.0.www2.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04141183 HP ProLiant Smart Array Embedded SATA RAID Controller Driver for Microsoft Windows Server 2012 and Microsoft Windows Server 2012 R2 Version: 6.32.64(B) Enhancements Support added for Microsoft Windows Small Business Server 2011 Standard and Essentials HP ProLiant Smart Array Embedded SATA RAID Controller Driver for Windows Server 2003/2008 Version: 6.10.64 (B) (Optional) Important Note! If the target controller was successfully updated to version 6.0.0.18.18. To improve rebuild time. then it is not necessary to update to version 6.18. HP | Service Pack for ProLiant 2014.HP ProLiant Servers: HP Dynamic Smart Array B120i/B320i Controllers .64 (A) (Optional) Enhancements Added support for Microsoft Windows Server 2012 R2 HP ProLiant Smart Array Embedded SATA RAID Controller Driver for Windows 2003/2008 x64 Editions Version: 6.0 Release Notes HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server 2008 Version: 6.18.0 447 .06.HP Service Pack for ProLiant 2014.32(A ) Fixes o o Corrects an issue where HP B110i would try to resume the rebuild progress if the drive was replaced while the server was offline.DRIVER UPGRADE REQUIRED to Ensure That a Drive Array Rebuild Does Not Target an Incorrect Drive and Cause Incorrect Data to Be Written to the Drive” http://h20564.0.0.64(A) of this driver.06.hp. then it is not necessary to update to version 6.32 (Critical) Fixes Fix for CA referenced below titled “SPP HOT FIX .0. ensure that drive write cache is enabled during rebuild and disabled when rebuild completes.18.4. www2.0 448 .el5 .28.jsp?objectID=c04184273 Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 (AMD64/EM64T) supported by this binary rpm are: 2.hp.el5 .18-308.6.com/bizsupport/TechSupport/Document.2.8-160 (Recommended) Fixes Fix for CA referenced below titled “SPP HOT FIX .Red Hat Enterprise Linux 5 Update 9 (AMD64/EM64T) and future errata kernels for HP | Service Pack for ProLiant 2014.LOG. The generated log file will be located on the target system in %SYSTEMROOT%\cpqsystem\log directory under the name CPQSETUP.6.6.HP ProLiant Gen8 Servers .2.0 Release Notes Top Driver .06.el5 . The generated log file will be located on the target system in the %SystemRoot%\cpqsystem\log directory under the name CPQSETUP.1 (C) (Optional) Enhancements Added support for the HP SC08Ge SAS Host Bus Adapter Enhanced component-level logging has been implemented in the Smart Component installer.06. HP 4/8 Internal Port SAS HBA with RAID and SCxxGe series HBA Driver for Windows Server 2008 x64 Editions Version: 1. HP Dynamic Smart Array SATA RAID Controller Driver for Red Hat Enterprise Linux 5 (AMD64/EM64T) Version: 1. 2.Storage Controller HP 4/8 Internal Port SAS HBA with RAID and SCxxGe series HBA Driver for Windows Server 2008 Version: 1.Red Hat Enterprise Linux 5 Update 7 (AMD64/EM64T) and future errata kernels for update 7.Red Hat Enterprise Linux 5 Update 8 (AMD64/EM64T) and future errata kernels for update 8.LOG. 2.28.HP Service Pack for ProLiant 2014.2.DRIVER UPGRADE REQUIRED to Avoid NMI in Linux on HP ProLiant Servers Under Heavy Load and Low Memory Configured with HP Dynamic Smart Array B120i / B320i Controllers Using the Optional FBWC” http://h20000.1 (B) (Optional) Enhancements Added support for the HP SC08Ge SAS Host Bus Adapter Enhanced component-level logging has been implemented in the smart component installer.18-348.18-274. 0 Release Notes update 9.06.0 449 . 2.Red Hat Enterprise Linux 5 Update 10 (AMD64/EM64T) and future errata kernels for update 10. HP Dynamic Smart Array SATA RAID Controller Driver for Red Hat Enterprise Linux 5 (x86) Version: 1.6.el5 .hp.HP ProLiant Gen8 Servers .8-160 (Recommended) Fixes Fix for CA referenced below titled “SPP HOT FIX .6. 2. 2.Red Hat Enterprise Linux 6 Update 1(AMD64/EM64T) and future errata kernels for update 1.Red Hat Enterprise Linux 6 Update 3(AMD64/EM64T) and future errata kernels for update 3.32-279. 2.6.Red Hat Enterprise Linux 6 Update 2(AMD64/EM64T) and future errata kernels for update 2.el5 .DRIVER UPGRADE REQUIRED to Avoid NMI in Linux on HP ProLiant Servers Under Heavy Load and Low Memory Configured with HP Dynamic Smart Array B120i / B320i Controllers Using the Optional FBWC” http://h20000.2. 2.06.18-348.6.32-431.32-358.Red Hat Enterprise Linux 5 Update 8 (x86) and future errata kernels for update 8.HP ProLiant Gen8 Servers .6.DRIVER UPGRADE REQUIRED to Avoid NMI in Linux on HP ProLiant Servers Under Heavy Load and Low Memory Configured with HP Dynamic Smart Array B120i / B320i Controllers Using the Optional FBWC” http://h20000.www2.jsp?objectID=c04184273 Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (AMD64/EM64T) supported by this by this binary rpm are: 2.6.HP Service Pack for ProLiant 2014.el6 .Red Hat Enterprise Linux 5 Update 9 (x86) and future errata kernels for update 9.www2.32-131.Red Hat Enterprise Linux 5 Update 7 (x86) and future errata kernels for update 7.hp.el6 .18-308. HP Dynamic Smart Array SATA RAID Controller Driver for Red Hat Enterprise Linux 6 (AMD64/EM64T) Version: 1.18-274.Red Hat Enterprise Linux 5 Update 10 (x86) and future errata kernels for update 10.el6 . 2. HP | Service Pack for ProLiant 2014.Red Hat Enterprise Linux 6 Update 4(AMD64/EM64T) and future errata kernels for update 4.6.com/bizsupport/TechSupport/Document.jsp?objectID=c04184273 Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 (x86) supported by this binary rpm are: 2.el5 .el5 .8-160 (Recommended) Fixes Fix for CA referenced below titled “SPP HOT FIX .32-220.18-371.18-371.el6 .el5 .6.2.el6 . 2.6.Red Hat Enterprise Linux 6 Update 5(AMD64/EM64T) and future errata kernels for update 5. 2.com/bizsupport/TechSupport/Document.6. 32-220. 2.DRIVER UPGRADE REQUIRED to Avoid NMI in Linux on HP ProLiant Servers Under Heavy Load and Low Memory Configured with HP Dynamic Smart Array B120i / B320i Controllers Using the Optional FBWC” http://h20000.6.DRIVER UPGRADE REQUIRED to Avoid NMI in Linux on HP ProLiant Servers Under Heavy Load and Low Memory Configured with HP Dynamic Smart Array B120i / B320i Controllers Using the Optional FBWC” http://h20000.jsp?objectID=c04184273 Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (x86) supported by this binary rpm are: 2. 2.hp.www2.6.32-279. 3.0 Release Notes HP Dynamic Smart Array SATA RAID Controller Driver for Red Hat Enterprise Linux 6 (x86) Version: 1.HP Service Pack for ProLiant 2014.8-160 (Recommended) Fixes Fix for CA referenced below titled “SPP HOT FIX .Red Hat Enterprise Linux 6 Update 5(x86) and future errata kernels for update 5.6.32-431. 2.8-160 (Recommended) Fixes Fix for CA referenced below titled “SPP HOT FIX .6.06.0 450 .el6 .hp.32.hp.06.SUSE LINUX Enterprise Server 11 SP 1 (AMD64/EM64T) and future errata kernels for SP 1.6.32-358.com/bizsupport/TechSupport/Document. 3.12-0.HP ProLiant Gen8 Servers .6.2.8-160 (Recommended) Fixes Fix for CA referenced below titled “SPP HOT FIX .www2.32-131.jsp?objectID=c04184273 HP | Service Pack for ProLiant 2014. HP Dynamic Smart Array SATA RAID Controller Driver for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 1.SUSE LINUX Enterprise Server 11 SP 2 (AMD64/EM64T) and future errata kernels for SP 2.2.0.0.11.2.com/bizsupport/TechSupport/Document. HP Dynamic Smart Array SATA RAID Controller Driver for SUSE LINUX Enterprise Server 11 (x86) Version: 1.76-0.HP ProLiant Gen8 Servers .el6 .SUSE LINUX Enterprise Server 11 SP 3 (AMD64/EM64T) and future errata kernels for SP 3. 2.com/bizsupport/TechSupport/Document.1 .www2.el6 .13-0.el6 .1 .Red Hat Enterprise Linux 6 Update 4(x86) and future errata kernels for update 4.HP ProLiant Gen8 Servers .Red Hat Enterprise Linux 6 Update 3(x86) and future errata kernels for update 3.DRIVER UPGRADE REQUIRED to Avoid NMI in Linux on HP ProLiant Servers Under Heavy Load and Low Memory Configured with HP Dynamic Smart Array B120i / B320i Controllers Using the Optional FBWC” http://h20000.7 .Red Hat Enterprise Linux 6 Update 2(x86) and future errata kernels for update 2.Red Hat Enterprise Linux 6 Update 1(x86) and future errata kernels for update 1.27.el6 .jsp?objectID=c04184273 Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (AMD64/EM64T) supported by this binary rpm are: 2. 3.64.32.SUSE LINUX Enterprise Server 11 SP 2 (x86) and future errata kernels for SP 2.27.SUSE LINUX Enterprise Server 11 SP 3 (x86) and future errata kernels for SP 3. HP | Service Pack for ProLiant 2014. HP H2xx SAS/SATA Host Bus Adapter Driver for Microsoft Windows Server 2008 x86 Editions Version: 2. HP H2xx SAS/SATA Host Bus Adapter Driver for Microsoft Windows Server 2008 R2 Editions Version: 2.64.76-0.0 .1 .HP Service Pack for ProLiant 2014.1 .64.11.68.0.06.0. HP H2xx SAS/SATA Host Bus Adapter Driver for Microsoft Windows Server 2012 R2 x64 Editions Version: 2.68.68.SUSE LINUX Enterprise Server 11 SP 1 (x86) and future errata kernels for SP 1.0 (Optional) 451 Enhancements Updated for Version Control across all LSI_sas2 Windows Drivers.64.6.13-0.0 (Optional) Enhancements Updated for Version Control across all LSI_sas2 Windows Drivers.0 (Optional) Enhancements Updated for Version Control across all LSI_sas2 Windows Drivers.0 (Optional) Enhancements Initial release HP H2xx SAS/SATA Host Bus Adapter Driver for Microsoft Windows Server 2012 x64 Editions Version: 2.7 .0 Release Notes Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (x86) supported by this binary rpm are: 2.64. 3.0 (Optional) Enhancements Updated for Version Control across all LSI_sas2 Windows Drivers.12-0. HP H2xx SAS/SATA Host Bus Adapter Driver for Microsoft Windows Server 2008 x64 Editions Version: 2.68.68.06. Red Hat Enterprise Linux 5 Update 5 (x86) and future errata kernels for update 5.Red Hat Enterprise Linux 5 Update 10 (AMD64/EM64T) and future errata kernels for update 10.18-238. 2.18-348.6.00-6 (Recommended) Enhancements Added support for Red Hat Enterprise Linux 5 Update 10. 2. 2.6. 2.10. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 (x86) supported by this binary rpm are: 2.0 .10.6.18-274.el5 . Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 (AMD64/EM64T) supported by this binary rpm are: 2.Red Hat Enterprise Linux 5 Update 5 (AMD64/EM64T) and future errata kernels for update 5. 2.Red Hat Enterprise Linux 5 Update 8 (x86) and future errata kernels for update 8. 452 HP H2xx SAS/SATA Host Bus Adapter Driver for Red Hat Enterprise Linux 6 (AMD64/EM64T) Version: 15.06.el5 .06.6.18-308.18-274.el5 .02.Red Hat Enterprise Linux 5 Update 9 (AMD64/EM64T) and future errata kernels for update 9.18-371.el5 .Red Hat Enterprise Linux 5 Update 10 (x86) and future errata kernels for update 10. 2.el5 .el5 .00-6 (Recommended) Enhancements Added support for Red Hat Enterprise Linux 5 Update 10.6. 2.18-371.Red Hat Enterprise Linux 5 Update 7 (x86) and future errata kernels for update 7. HP H2xx SAS/SATA Host Bus Adapter Driver for Red Hat Enterprise Linux 5 (x86) Version: 15.Red Hat Enterprise Linux 5 Update 6 (x86) and future errata kernels for update 6.HP Service Pack for ProLiant 2014.18-348. 2.6.0 Release Notes HP H2xx SAS/SATA Host Bus Adapter Driver for Red Hat Enterprise Linux 5 (AMD64/EM64T) Version: 15.6.Red Hat Enterprise Linux 5 Update 9 (x86) and future errata kernels for update 9.02.el5 .Red Hat Enterprise Linux 5 Update 6 (AMD64/EM64T) and future errata kernels for update 6. 2.6.6.18-238.6.el5 .Red Hat Enterprise Linux 5 Update 7 (AMD64/EM64T) and future errata kernels for update 7.el5 .00-8 (Recommended) HP | Service Pack for ProLiant 2014.02.6.10.6.18-194.el5 .el5 . 2.Red Hat Enterprise Linux 5 Update 8 (AMD64/EM64T) and future errata kernels for update 8.el5 .18-194.18-308. 2.32-358.Red Hat Enterprise Linux 6 Update 5(AMD64/EM64T) and future errata kernels for update 5. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (AMD64/EM64T) supported by this binary rpm are: 2.10.el6 .10. 2.06. HP H2xx SAS/SATA Host Bus Adapter Driver for Red Hat Enterprise Linux 6 (x86) Version: 15.32-431.00-6 (Recommended) Enhancements Minor changes to scripts for post driver BAT run. 2.Red Hat Enterprise Linux 6 Update 2(x86) and future errata kernels for update 2.el6 .el6 .32-279.32-431.Red Hat Enterprise Linux 6 Update 1(x86) and future errata kernels for update 1.el6 .32-220.Red Hat Enterprise Linux 6 Update 2(AMD64/EM64T) and future errata kernels for update 2.32-220.6. 2.7 .6.6.6.el6 .32-131. 2.Red Hat Enterprise Linux 6 Update 5(x86) and future errata kernels for update 5.Red Hat Enterprise Linux 6 Update 3(AMD64/EM64T) and future errata kernels for update 3. 2. HP | Service Pack for ProLiant 2014. 2.6.02.Red Hat Enterprise Linux 6 Update 1(AMD64/EM64T) and future errata kernels for update 1.6.el6 .el6 .SUSE LINUX Enterprise Server 11 SP 1 (AMD64/EM64T) plus future errata.32-279.6.02.06.HP Service Pack for ProLiant 2014. Supported Devices and Features 453 SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (AMD64/EM64T) supported by this driver diskette are: 2.0 .6.12-0.6. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (x86) supported by this binary rpm are: 2.Red Hat Enterprise Linux 6 Update 4(AMD64/EM64T) and future errata kernels for update 4.el6 .32-358.00-8 (Recommended) Enhancements Added support for Red Hat Enterprise Linux 6 Update 5.el6 .el6 .6.Red Hat Enterprise Linux 6 Update 3(x86) and future errata kernels for update 3.32-131.6. HP H2xx SAS/SATA Host Bus Adapter Driver for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 15. 2.0 Release Notes Enhancements Added support for Red Hat Enterprise Linux 6 Update 5.32.Red Hat Enterprise Linux 6 Update 4(x86) and future errata kernels for update 4. SUSE LINUX Enterprise Server 11 SP 2 (AMD64/EM64T) plus future errata.10273.1.27.00-6 (Recommended) Enhancements Minor changes to scripts for post driver BAT run.SUSE LINUX Enterprise Server 11 SP 2 (x86) plus future errata.1.1. HP H2xx SAS/SATA Host Bus Adapter Driver for SUSE LINUX Enterprise Server 11 (x86) Version: 15.HP Service Pack for ProLiant 2014.6.02.SUSE LINUX Enterprise Server 11 SP 3 (x86) plus future errata.1 (Recommended) Fixes This driver release fixes a bugcheck 0xD1 that occurs when the Symantec Netbackup does a shadow copy of Microsoft Window 2008.10273.0. HP ProLiant Integrated SATA Controller Driver for Microsoft Windows Server 2008 R2 Version: 1.1 .12-0.13-0. 3.0. 3.06.11. Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (x86) supported by this driver diskette are: 2.10273.11.0.32.1 (Recommended) Fixes This driver release fixes a bugcheck 0xD1 that occurs when the Symantec Netbackup does a shadow copy of Microsoft Window 2008.SUSE LINUX Enterprise Server 11 SP 3 (AMD64/EM64T) plus future errata.0 Release Notes 3.06.0.10.27.76-0. HP ProLiant Integrated SATA Controller Driver for Windows Server 2008 x86 Edition Version: 1.1 .1. HP | Service Pack for ProLiant 2014.1 (Recommended) Fixes This driver release fixes a bugcheck 0xD1 that occurs when the Symantec Netbackup does a shadow copy of Microsoft Window 2008 R2.0 454 .1 . 3.76-0.7 .SUSE LINUX Enterprise Server 11 SP 1 (x86) plus future errata. HP ProLiant Integrated SATA Controller Driver for Windows Server 2008 x64 Edition Version: 1.13-0. 32 (C) (Optional) Enhancements No functional changes have occurred for the driver. then you do not need to upgrade to version 6.0.LOG. 3.7 .6.32.6.8.SUSE LINUX Enterprise Server 11 SP 2 (AMD64/EM64T) and future errata kernels for SP 2.8.0. If you have previously installed version 6.SUSE LINUX Enterprise Server 11 SP 3 (AMD64/EM64T) and future errata kernels for SP 3.64(E) of this driver. If you have previously installed version 6. HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 4.76-0.0.32(B) of this driver.8.1 .0.32(C).0 .0 Release Notes HP ProLiant Smart Array 5x and 6x Controller Driver for Windows Server 2003/2008 x64 Editions Version: 6. HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for Red Hat Enterprise Linux 5 (AMD64/EM64T) Version: 3.27.8.8.8.0.11.13-0. only enhanced component-level logging has been implemented in the smart component installer.0. The generated log file will be located on the target system in %SYSTEMROOT%\cpqsystem\log directory under the name CPQSETUP. HP | Service Pack for ProLiant 2014.28-24 (Recommended) Fixes Minor fix to tape drive error handling code.6.0.1 .SUSE LINUX Enterprise Server 11 SP 1 (AMD64/EM64T) and future errata kernels for SP 1. only enhanced component-level logging has been implemented in the smart component installer. 3.06.06. The generated log file will be located on the target system in %SYSTEMROOT%\cpqsystem\log directory under the name CPQSETUP. HP ProLiant Smart Array 5x and 6x Controller Driver for Windows Server 2008 Version: 6.12-0. Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (AMD64/EM64T) supported by this binary rpm are: 2.LOG. then you do not need to upgrade to version 6.0.28-24 (Recommended) 455 Fixes Minor fix to tape drive error handling code.64 (F) (Optional) Enhancements No functional changes have occurred for the driver.64(F).HP Service Pack for ProLiant 2014. el6 .el6 .el6 .Red Hat Enterprise Linux 6 Update 2(AMD64/EM64T) and future errata kernels for update 2.Red Hat Enterprise Linux 6 Update 3(AMD64/EM64T) and future errata kernels for update 3. 2.0 Release Notes Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 (AMD64/EM64T) supported by this binary rpm are: 2.el5 .32-358.4-125 (Recommended) 456 Enhancements o Added HPSSD Smart Path feature.28-24 (Recommended) Fixes Minor fix to tape drive error handling code.el6 .6.el6 .Red Hat Enterprise Linux 6 Update 1(AMD64/EM64T) and future errata kernels for update 1. HP | Service Pack for ProLiant 2014. 2. HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for Red Hat Enterprise Linux 6 (AMD64/EM64T) Version: 4.6.6.32-431.6.32-220.Red Hat Enterprise Linux 6 Update 5(AMD64/EM64T) and future errata kernels for update 5.18-308.el5 .6.6.6. 2.6.06.el5 .0 .Red Hat Enterprise Linux 5 Update 7 (AMD64/EM64T) and future errata kernels for update 7.Red Hat Enterprise Linux 6 Update 4(AMD64/EM64T) and future errata kernels for update 4.Red Hat Enterprise Linux 5 Update 9 (AMD64/EM64T) and future errata kernels for update 9.06.4.Red Hat Enterprise Linux 5 Update 8 (AMD64/EM64T) and future errata kernels for update 8. Enhancements Added support for Red Hat Enterprise Linux 6 Update 5.HP Service Pack for ProLiant 2014.6.6.18-274. 2.18-339. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (AMD64/EM64T) supported by this binary rpm are: 2. 2.18-371. HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for Red Hat Enterprise Linux 6 (AMD64/EM64T) Version: 3. 2.Red Hat Enterprise Linux 5 Update 10 (AMD64/EM64T) and future errata kernels for update 10.32-131.el5 .32-279. 2. 32-431.HP Service Pack for ProLiant 2014.32. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (AMD64/EM64T) supported by this binary rpms are: 2.13-0.11.6.Red Hat Enterprise Linux 6 Update 2 (AMD64/EM64T) and future errata kernels for update 2.SUSE LINUX Enterprise Server 11 SP 3 (AMD64/EM64T) and future errata kernels for SP 3.1 .6.32-358.Red Hat Enterprise Linux 6 Update 3 (AMD64/EM64T) and future errata kernels for update 3.32-131. Added support for Red Hat Enterprise Linux 6 Update 5.el6 . Added support for HP Smart Array Px3x Controllers. Supported Devices and Features HP | Service Pack for ProLiant 2014.el6 .6.el6 . 2.1 .0.06.SUSE LINUX Enterprise Server 11 SP 2 (AMD64/EM64T) and future errata kernels for SP 2.0.6.28-24 (Recommended) Fixes 457 Minor fix to tape drive error handling code. Added support for HP Secure Encryption. Added support for HP Smart Array Px3x Controllers.32-279. Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (AMD64/EM64T) supported by this binary rpm are: 2.el6 .0 .6.Red Hat Enterprise Linux 6 Update 4 (AMD64/EM64T) and future errata kernels for update 4. 3.4.7 . 2.SUSE LINUX Enterprise Server 11 SP 1 (AMD64/EM64T) and future errata kernels for SP 1.0 Release Notes o o o Added support for HP Secure Encryption. HP ProLiant Smart Array Controller (x86/AMD32) Driver for Red Hat Enterprise Linux 5 (x86) Version: 3.76-0.27.4-125 (Recommended) Enhancements o o o Added HPSSD Smart Path feature.Red Hat Enterprise Linux 6 Update 5 (AMD64/EM64T) and future errata kernels for update 5.6. 2.Red Hat Enterprise Linux 6 Update 1 (AMD64/EM64T) and future errata kernels for update 1. HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 3.32-220.06.6. 2.el6 . 3.12-0. 2.el5 .6.0 .el5 .el6 .6.HP Service Pack for ProLiant 2014.32-279. 2.6. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (x86) supported by this binary rpm are: 2.6.18-308.06.el6 .28-24 (Recommended) Fixes Minor fix to tape drive error handling code.0 Release Notes SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 (x86) supported by this binary rpm are: 2.Red Hat Enterprise Linux 5 Update 7 (x86) and future errata kernels for update 7.18-274.18-339. 2.Red Hat Enterprise Linux 6 Update 5(x86) and future errata kernels for update 5.6.6.Red Hat Enterprise Linux 5 Update 8 (x86) and future errata kernels for update 8.32-131.6.Red Hat Enterprise Linux 6 Update 1(x86) and future errata kernels for update 1.el6 .Red Hat Enterprise Linux 5 Update 9 (x86) and future errata kernels for update 9.4-125 (Recommended) Enhancements o o o o Added HPSSD Smart Path feature. 2.el6 .el6 . 2.el5 .32-220.06. 458 Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (x86) supported by this binary rpm are: HP | Service Pack for ProLiant 2014.el5 .Red Hat Enterprise Linux 6 Update 2(x86) and future errata kernels for update 2. Added support for Red Hat Enterprise Linux 6 Update 5. 2.6. Enhancements Added support for Red Hat Enterprise Linux 6 Update 5.Red Hat Enterprise Linux 6 Update 4(x86) and future errata kernels for update 4. HP ProLiant Smart Array Controller (x86/AMD32) Driver for Red Hat Enterprise Linux 6 (x86) Version: 3.Red Hat Enterprise Linux 6 Update 3(x86) and future errata kernels for update 3.6. HP ProLiant Smart Array Controller (x86/AMD32) Driver for Red Hat Enterprise Linux 6 (x86) Version: 4.4. Added support for HP Secure Encryption.32-358.Red Hat Enterprise Linux 5 Update 10 (x86) and future errata kernels for update 10. 2.32-431. Added support for HP Smart Array Px3x Controllers.6.18-371. 2.32-431.el6 .6.SUSE LINUX Enterprise Server 11 SP 2 (x86) and future errata kernels for SP 2.0 459 .7 .1 .32.6.0. 2. 2.12-0.0.6.Red Hat Enterprise Linux 6 Update 2(x86) and future errata kernels for update 2.0.6.32 (C) (Optional) Enhancements HP | Service Pack for ProLiant 2014. 3.4-125 (Recommended) Enhancements o o o Added HPSSD Smart Path feature.el6 .76-0.1 . Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (x86) supported by this binary rpm are: 2.el6 .28-24 (Recommended) Fixes Minor fix to tape drive error handling code.el6 . HP ProLiant Smart Array Controller (x86/AMD32) Driver for SUSE LINUX Enterprise Server 11 (x86) Version: 4.1 .13-0.32-358. HP ProLiant Smart Array Controller (x86/AMD32) Driver for SUSE LINUX Enterprise Server 11 (x86) Version: 3. Added support for HP Secure Encryption.32-131.0 Release Notes 2.7 .32-279.06.76-0.32-220.1 .Red Hat Enterprise Linux 6 Update 3(x86) and future errata kernels for update 3.06.32.12-0. HP ProLiant Smart Array Device Manager Extension for Windows Server 2003/2008 Version: 6.HP Service Pack for ProLiant 2014. 3.6.13-0.6.SUSE LINUX Enterprise Server 11 SP 1 (x86) and future errata kernels for SP 1.SUSE LINUX Enterprise Server 11 SP 1 (x86) and future errata kernels for SP 1.27.6.Red Hat Enterprise Linux 6 Update 4(x86) and future errata kernels for update 4. 2. Added support for HP Smart Array Px3x Controllers.6.0.Red Hat Enterprise Linux 6 Update 5(x86) and future errata kernels for update 5.SUSE LINUX Enterprise Server 11 SP 3 (x86) and future errata kernels for SP 3.el6 .6.0. 3. 3.SUSE LINUX Enterprise Server 11 SP 3 (x86) and future errata kernels for SP 3.27.11.4.11.Red Hat Enterprise Linux 6 Update 1(x86) and future errata kernels for update 1. Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (x86) supported by this binary rpm are: 2.SUSE LINUX Enterprise Server 11 SP 2 (x86) and future errata kernels for SP 2. LOG.HP Service Pack for ProLiant 2014. HP ProLiant Smart Array HPCISSS3 Controller Driver for Windows Server 2008 x64 Edition Version: 6.64 (Optional) Enhancements o o Peformance improvments for MPIO bases solutions using MSA 2040 and P2000 storage enclosures.6.64(D). only enhanced component-level logging has been implemented in the smart component installer.0. Improved performance for certain configurations using SSD SmartPath.4.32(C).4.06.32(B) of this Device Manager Extension. The generated log file will be located on the target system in %SYSTEMROOT%\cpqsystem\log directory under the name CPQSETUP.06.0.6.32 (Optional) Enhancements o o Peformance improvments for MPIO bases solutions using MSA 2040 and P2000 storage enclosures. then you do not need to upgrade to version 6. The generated log file will be located on the target system in %SYSTEMROOT%\cpqsystem\log directory under the name CPQSETUP.64 (Optional) HP | Service Pack for ProLiant 2014.64(C) of this Device Manager Extension.64 (D) (Optional) Enhancements No functional changes have occurred for the Device Manager Extension.0.6.0 460 .0.0 Release Notes No functional changes have occurred for the Device Manager Extension.0.6. then you do not need to upgrade to version 6.0.0.6. HP ProLiant Smart Array Device Manager Extension for Windows Server 2003/2008 x64 Editions Version: 6.0. If you have previously installed version 6. Improved performance for certain configurations using SSD SmartPath. HP ProLiant Smart Array HPCISSS3 Controller Driver for Windows Server 2012 x64 Edition Version: 62.4. If you have previously installed version 6.LOG. HP ProLiant Smart Array HPCISSS3 Controller Driver for Windows Server 2008 Version: 6. only enhanced component-level logging has been implemented in the smart component installer. 64 (Critical) Fixes Fixed errors occuring with 62.0 Release Notes Enhancements o o Peformance improvments for MPIO bases solutions using MSA 2040 and P2000 storage enclosures. Improved performance for certain configurations using SSD SmartPath.28.32 (Optional) Enhancements Minor performance enhancements HP ProLiant Smart Array SAS/SATA Controller Driver for Windows Server 2008 x64 Edition Version: 6.28.28.com/bizsupport/TechSupport/Document. HP ProLiant Smart Array SAS/SATA Controller Driver for Windows Server 2012 x64 Edition Version: 62.0.06.jsp?objectID=c03793656 Enhancements Support for Windows 2012 R2 HP Smart Array B110i SATA RAID Controller Driver for Red Hat Enterprise Linux 5 (EM64T) Version: 1.26.2. This issue resolves the customer advisory c03793656 described at the following link:http://h20000. HP ProLiant Smart Array SAS/SATA Controller Driver for Windows Server 2008 Version: 6.64 version which included a possible bluescreen or system hang when running I/O on Windows Server 2012.0.hp.06.6-16 (Optional) Enhancements HP | Service Pack for ProLiant 2014.0.0.www2.64 (Optional) Enhancements o Enables customers to make use of Microsoft HotFix which enables 64-bit command addressing described by MS KB2468345.0 461 .HP Service Pack for ProLiant 2014. Red Hat Enterprise Linux 5 Update 7 (AMD64/EM64T) and future errata kernels for update 7.18-308.6.2. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 (AMD64/EM64T) supported by this binary rpm are: 2.18-274.Red Hat Enterprise Linux 5 Update 10 (AMD64/EM64T) and future errata kernels for update 10.el5 . 2. 2.18-371.Red Hat Enterprise Linux 5 Update 7 (x86) and future errata kernels for update 7.el5 .6.Red Hat Enterprise Linux 5 Update 9 (x86) and future errata kernels for update 9. 2.06.0 .6.18-371.0 Release Notes Added support for Red Hat Enterprise Linux 5 Update 10.el5 .HP Service Pack for ProLiant 2014.el5 .2.18-339.6-16 (Optional) Enhancements Added support for Red Hat Enterprise Linux 5 Update 10.el5 . 2.6-17 (Recommended) Enhancements Added support for Red Hat Enterprise Linux 6 Update 5. 2.el5 . 2.Red Hat Enterprise Linux 5 Update 9 (AMD64/EM64T) and future errata kernels for update 9.el5 .6.el5 .06.18-308. HP Smart Array B110i SATA RAID Controller Driver for Red Hat Enterprise Linux 6 (AMD64/EM64T) Version: 1. 462 Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (AMD64/EM64T) supported by this binary rpm are: HP | Service Pack for ProLiant 2014.Red Hat Enterprise Linux 5 Update 8 (AMD64/EM64T) and future errata kernels for update 8.Red Hat Enterprise Linux 5 Update 10 (x86) and future errata kernels for update 10.Red Hat Enterprise Linux 5 Update 8 (x86) and future errata kernels for update 8.18-339. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 5 (x86) supported by this binary rpm are: 2.6. HP Smart Array B110i SATA RAID Controller Driver for Red Hat Enterprise Linux 5 (x86) Version: 1.6.18-274.6.6. 0 Release Notes 2.32-279.11. 2.2.32-220. HP Smart Array B110i SATA RAID Controller Driver for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 1.HP Service Pack for ProLiant 2014.el6 .6. 2.6-17 (Recommended) Enhancements Added support for Red Hat Enterprise Linux 6 Update 5.27. 2. Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (AMD64/EM64T) supported by this binary rpm are: 2.Red Hat Enterprise Linux 6 Update 3(AMD64/EM64T) and future errata kernels for update 3.Red Hat Enterprise Linux 6 Update 3(x86) and future errata kernels for update 3. HP Smart Array B110i SATA RAID Controller Driver for Red Hat Enterprise Linux 6 (x86) Version: 1.32-131. 2.6.2.32-220.Red Hat Enterprise Linux 6 Update 4(x86) and future errata kernels for update 4. 2.el6 .76-0.06.Red Hat Enterprise Linux 6 Update 1(AMD64/EM64T) and future errata kernels for update 1.32-358.32. 3.0.Red Hat Enterprise Linux 6 Update 2(x86) and future errata kernels for update 2. 2. 3. Supported Devices and Features SUPPORTED KERNELS: The kernels of Red Hat Enterprise Linux 6 (x86) supported by this binary rpm are: 2.06.Red Hat Enterprise Linux 6 Update 5(AMD64/EM64T) and future errata kernels for update 5.el6 .6. 2.el6 .2.6. HP Smart Array B110i SATA RAID Controller Driver for SUSE LINUX Enterprise Server 11 (x86) Version: 1.1 .el6 .6-17 (Recommended) Enhancements Added support for Secure Boot.32-279. 2.el6 .Red Hat Enterprise Linux 6 Update 1(x86) and future errata kernels for update 1.32-131.0.el6 .el6 .6.13-0.32-358.0 463 .32-431.6.SUSE LINUX Enterprise Server 11 SP 1 (AMD64/EM64T) and future errata kernels for SP 1.6.6.6.SUSE LINUX Enterprise Server 11 SP 2 (AMD64/EM64T) and future errata kernels for SP 2.6.6-17 (Recommended) HP | Service Pack for ProLiant 2014.12-0.1 .el6 .Red Hat Enterprise Linux 6 Update 2(AMD64/EM64T) and future errata kernels for update 2.7 .32-431.Red Hat Enterprise Linux 6 Update 4(AMD64/EM64T) and future errata kernels for update 4.el6 .Red Hat Enterprise Linux 6 Update 5(x86) and future errata kernels for update 5.SUSE LINUX Enterprise Server 11 SP 3 (AMD64/EM64T) and future errata kernels for SP 3.6. user modification of the I/O Interrupt Latency take effect immediately.HP Service Pack for ProLiant 2014.6.12-0.0.SUSE LINUX Enterprise Server 11 SP 1 (x86) and future errata kernels for SP 1.11.0 464 .13-0.Storage Fibre Channel HP Storage Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2012 Version: 3.0 Release Notes Enhancements Added support for Secure Boot. Supported Devices and Features SUPPORTED KERNELS: The kernels of SUSE LINUX Enterprise Server 11 (x86) supported by this binary rpm are: 2. Enhancements Update driver to version 3. Supported Devices and Features This driver supports the following HP adapters: o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter HP | Service Pack for ProLiant 2014.1 . changing dev_loss_tmo will no longer cause the user configured path tov to change.32. be sure to update your adapter with the latest boot image from www.27.1.06. 3.2.2. Also.SUSE LINUX Enterprise Server 11 SP 2 (x86) and future errata kernels for SP 2. 3. For Brocade 4 and 8 Gb FC HBAs.0.com before you install or update adapter driver packages.0 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes To keep drivers and boot code synchronized.0.1. Top Driver .SUSE LINUX Enterprise Server 11 SP 3 (x86) and future errata kernels for SP 3.7 .06. ja Fixes o o The user configured path tov now persists across server reboots.hp.76-0.1 . 76.HP Service Pack for ProLiant 2014.1 (b) (Recommended) Important Note! Use this driver component if you are updating from a previous version as it contains a correction for a reported false driver installation failure. Release Notes: HP StorageWorks Emulex Adapters Release Notes 465 Fixes The current Emulex Windows driver install kit blindly interprets any non-zero return value from the APinstall as a failure.hp.06. This is a kit installer change only.2. There is no change to the driver binary. The HP | Service Pack for ProLiant 2014.0 Release Notes o Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Storage Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2012 R2 Version: 3.3. This would indicate a false failure when the error code was 3010 (Success but needs reboot). be sure to update your adapter with the latest boot image from www.3.1 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes To keep drivers and boot code synchronized.06.com before you install or update adapter driver packages. ja Enhancements Initial driver to support Microsoft Windows Server 2012 R2 Supported Devices and Features This driver supports the following HP adapters: o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Storage Fibre Channel Adapter Kit for the Emulex Storport Driver for Windows Server 2012 and 2012 R2 Version: 2.0 . 1.11.06. Supported Devices and Features o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2. Enhancements This driver version is now supported on Windows Server 2012.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.0 466 .0 Release Notes installer code has been revised to return an exit code of Success for this condition. Supported Devices and Features This driver supports the following HP adapters: o o o o o o o o o HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA HP StorageWorks FC1243 4Gb PCI-X 2.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz Host bus Adapter HP Storage Fibre Channel Adapter Kit for the QLogic Storport Driver for Windows Server 2012 and 2012 R2 Version: 9.06.HP Service Pack for ProLiant 2014.0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP | Service Pack for ProLiant 2014.24 (B) (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes Fixes This driver update resolves an issue where disks appear as local and not as FC or FCoE disks on Windows 2012 R2 hosts with Qlogic HBAs and CNAs when viewed by the Virtual Machine Manager (VMM) product of the HP Insight Control suite of products. 0 . There is no change to the driver binary.06. Supported Devices and Features o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.1 (b) (Recommended) Important Note! Use this driver component if you are updating from a previous version as it contains a correction for a reported false driver installation failure.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.20 (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes 467 Prerequisites HP | Service Pack for ProLiant 2014.06.1.HP Service Pack for ProLiant 2014.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz Adapter HP Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver Version: 9.11.3. This is a kit installer change only. The installer code has been revised to return an exit code of Success for this condition.76.0 Release Notes o HP QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver Version: 2. Release Notes: HP StorageWorks Emulex Adapters Release Notes Fixes The current Emulex Windows driver install kit blindly interprets any non-zero return value from the APinstall as a failure. This would indicate a false failure when the error code was 3010 (Success but needs reboot). 0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP Storage Fibre Channel Adapter Kit for the x86 Emulex Storport Driver Version: 2. Removed restrictions on writing mbx8 register The "Execution Throttle" field in nvram for 2600 series adapters can now be modified Added the ability to read 2600 series adapters ASIC temperature Added the ability to read ASIC temperature for OEM Adapters Added support for full 64 bit physical addressing Added support for the QLE10000 series adapters Removed support for 2Gb speed in port supported speed for 16Gb FC in 2600 series adapters External loopback supports OEM adapters when in loop mode Supported Devices and Features This driver supports the following HP adapters: o o o o o o o o o o HP StorageWorks FC1143 4Gb PCI-X 2.0 Release Notes Fixes o o Fixed Ext Loopback test fails with Loopback connector (8Gb loop mode) The fwdump routine no longer terminates unexpectedly Enhancements o o o o o o o o o o Added support for HP QMH2672 16Gb FC HBA Updated the Smart Component with driver version 9.76.0 HBA HP StorageWorks FC1243 4Gb PCI-X 2.0 .06.11.1. There is no change to the driver binary.HP Service Pack for ProLiant 2014.1 (b) (Recommended) 468 Important Note! Use this driver component if you are updating from a previous version as it contains a correction for a reported false driver installation failure.06. This is a kit installer HP | Service Pack for ProLiant 2014.3.20. This would indicate a false failure when the error code was 3010 (Success but needs reboot).11.0 Release Notes change only. Supported Devices and Features o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.HP Service Pack for ProLiant 2014.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz Adapter HP Storage Fibre Channel Adapter Kit for the x86 QLogic Storport Driver Version: 9.20 (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes Prerequisites Fixes 469 o o Fixed Ext Loopback test fails with Loopback connector (8Gb loop mode) The fwdump routine no longer terminates unexpectedly HP | Service Pack for ProLiant 2014.1. Release Notes: HP StorageWorks Emulex Adapters Release Notes Fixes The current Emulex Windows driver install kit blindly interprets any non-zero return value from the APinstall as a failure.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.06. The installer code has been revised to return an exit code of Success for this condition.0 .06. 0 HBA HP StorageWorks FC1243 4Gb PCI-X 2.0 470 . There is no change to the driver binary. This would indicate a false failure when the error code was 3010 (Success but needs reboot).1.1 (b) (Recommended) Important Note! Use this driver component if you are updating from a previous version as it contains a correction for a reported false driver installation failure.20.0 Release Notes Enhancements o o o o o o o o o o Added support for HP QMH2672 16Gb FC HBA Updated the Smart Component with driver version 9.06. Removed restrictions on writing mbx8 register The "Execution Throttle" field in nvram for 2600 series adapters can now be modified Added the ability to read 2600 series adapters ASIC temperature Added the ability to read ASIC temperature for OEM Adapters Added support for full 64 bit physical addressing Added support for the QLE10000 series adapters Removed support for 2Gb speed in port supported speed for 16Gb FC in 2600 series adapters External loopback supports OEM adapters when in loop mode Supported Devices and Features This driver supports the following HP adapters: o o o o o o o o o o HP StorageWorks FC1143 4Gb PCI-X 2.3. This is a kit installer change only.0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2672 16Gb FC HBA for c-Class BladeSystem HP Storage Fibre Channel Over Ethernet Adapter Kit for the Emulex Storport Driver for Windows Server 2012 and 2012 R2 Version: 2.HP Service Pack for ProLiant 2014. Release Notes: HP StorageWorks Emulex Adapters Release Notes Fixes The current Emulex Windows driver install kit blindly interprets any non-zero return value from the APinstall as a failure.11.06. The installer HP | Service Pack for ProLiant 2014.76. 0 Release Notes code has been revised to return an exit code of Success for this condition.11.06.HP Service Pack for ProLiant 2014. Enhancements This driver version now supports Windows Server 2012.76.0 471 .1 (b) (Recommended) Important Note! Use this driver component if you are updating from a previous version as it contains a correction for a reported false driver installation failure.06. Supported Devices and Features This driver supports the following HP adapters: o o HP CN1000Q Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP Storage Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver Version: 2. HP | Service Pack for ProLiant 2014. There is no change to the driver binary. This is a kit installer change only.12 (B) (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes Fixes This driver update resolves an issue where disks appear as local and not as FC or FCoE disks on Windows 2012 R2 hosts with Qlogic HBAs and CNAs when viewed by the Virtual Machine Manager (VMM) product of the HP Insight Control suite of products.1.3. Supported Devices and Features This driver supports the following HP adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric 10Gb Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric 10Gb Converged Network Adapter HP StorageWorks CN1000E Dual Port Converged Network Adapter HP StorageWorks CN1100E Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP Storage Fibre Channel Over Ethernet Adapter Kit for the QLogic Storport Driver for Windows Server 2012 and 2012 R2 Version: 9. 06.1. Supported Devices and Features This driver supports the following HP adapters: o o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric 10Gb Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric 10Gb Converged Network Adapter HP StorageWorks CN1000E Dual Port Converged Network Adapter HP StorageWorks CN1100E Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP Storage Fibre Channel Over Ethernet Adapter Kit for the x64 QLogic Storport Driver Version: 9.1.19 (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes Fixes o o o Fixed empty firmware image version due to 8200 Series adapter (based on latest controller revision) not recognized by driver Fixed BSOD that occurred when running the FCoE Internal loopback when the mailbox set config fails Fixed crash in fwdump routine.0 .19.0 Release Notes Release Notes: HP StorageWorks Emulex Adapters Release Notes Fixes The current Emulex Windows driver install kit blindly interprets any non-zero return value from the APinstall as a failure.10.10.06. The installer code has been revised to return an exit code of Success for this condition. HP | Service Pack for ProLiant 2014. This would indicate a false failure when the error code was 3010 (Success but needs reboot).HP Service Pack for ProLiant 2014. now dumps fw 472 Enhancements o Updated the Smart Component to contain driver version 9. Supported Devices and Features This driver supports the following HP adapters: o o o o o o o o HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC553i 10Gb 2-port FlexFabric 10Gb Converged Network Adapter HP NC553m 10Gb 2-port FlexFabric 10Gb Converged Network Adapter HP StorageWorks CN1000E Dual Port Converged Network Adapter HP StorageWorks CN1100E Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP | Service Pack for ProLiant 2014.76.06. There is no change to the driver binary.0 473 .0 Release Notes o o o o o o Added 8300 series Adapter temperature handling Added adapter disable check on timer routine re-init state handling Added registry commands to control the IO timeout event log/sense data report for Microsoft Windows 12 Removed event logging for fw dump event Limited the MSI-X resources to 2 Use macros to access SRB and SRB_EXT for Microsoft Windows 12 Supported Devices and Features This driver supports the following HP adapters: o o HP CN1000Q Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP Storage Fibre Channel Over Ethernet Adapter Kit for the x86 Emulex Storport Driver Version: 2. Release Notes: HP StorageWorks Emulex Adapters Release Notes Fixes The current Emulex Windows driver install kit blindly interprets any non-zero return value from the APinstall as a failure.3.06. The installer code has been revised to return an exit code of Success for this condition.1 (b) (Recommended) Important Note! Use this driver component if you are updating from a previous version as it contains a correction for a reported false driver installation failure. This is a kit installer change only.HP Service Pack for ProLiant 2014. This would indicate a false failure when the error code was 3010 (Success but needs reboot). Added 8300 series Adapter temperature handling Added adapter disable check on timer routine re-init state handling Added registry commands to control the IO timeout event log/sense data report for Microsoft Windows 12 Removed event logging for fw dump event Limited the MSI-X resources to 2 Use macros to access SRB and SRB_EXT for Microsoft Windows 12 Supported Devices and Features This driver supports the following HP adapters: o o HP CN1000Q Dual Port Converged Network Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP Storage x64 Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2008 Version: 3.0 474 .10.1. now dumps fw Enhancements o o o o o o o Updated the Smart Component to contain driver version 9.06.19 (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes Fixes o o o Fixed empty firmware image version due to 8200 Series adapter (based on latest controller revision) not recognized by driver Fixed BSOD that occurred when running the FCoE Internal loopback when the mailbox set config fails Fixed crash in fwdump routine.19.2.10.06.1.1.HP Service Pack for ProLiant 2014.0 Release Notes o HP FlexFabric 10Gb 2-port 554M Adapter HP Storage Fibre Channel Over Ethernet Adapter Kit for the x86 QLogic Storport Driver Version: 9.0 (Optional) Important Note! HP | Service Pack for ProLiant 2014. 06.0 .1.com before you install or update adapter driver packages.0 Release Notes Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes To keep drivers and boot code synchronized. Enhancements Updated driver version to 3. Also. user modification of the I/O Interrupt Latency take effect immediately. changing dev_loss_tmo will no longer cause the user configured path tov to change. Prerequisites KB968675 (or higher) is recommended.2.com before you install or update adapter driver packages.0. Supported Devices and Features This driver supports the following HP adapters: o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Storage x64 Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2008 R2 Version: 3.HP Service Pack for ProLiant 2014.0 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes To keep drivers and boot code synchronized.2.hp.1. Fixes o o The user configured path tov now persists across server reboots.06. For Brocade 4 and 8 Gb FC HBAs.hp. 475 Fixes HP | Service Pack for ProLiant 2014. be sure to update your adapter with the latest boot image from www. This KB fixes a non paged memory leak in Windows 2008 storage stack. be sure to update your adapter with the latest boot image from www. Enhancements Updated driver version to 3.06.HP Service Pack for ProLiant 2014.hp.06.0. user modification of the I/O Interrupt Latency take effect immediately. user modification of the I/O Interrupt Latency take effect immediately. Fixes o o The user configured path tov now persists across server reboots.0.com before you install or update adapter driver packages. be sure to update your adapter with the latest boot image from www.1. changing dev_loss_tmo will no longer cause the user configured path tov to change. For Brocade 4 and 8 Gb FC HBAs. Also. Supported Devices and Features This driver supports the following HP adapters: HP | Service Pack for ProLiant 2014.2. This KB fixes a non paged memory leak in Windows 2008 storage stack. changing dev_loss_tmo will no longer cause the user configured path tov to change. For Brocade 4 and 8 Gb FC HBAs.2.1. 476 Enhancements Updated driver version to 3.0 .0 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes To keep drivers and boot code synchronized. Prerequisites KB968675 (or higher) is recommended. Also. Supported Devices and Features This driver supports the following HP adapters: o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Storage x86 Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2008 Version: 3.0 Release Notes o o The user configured path tov now persists across server reboots.1.2. For Brocade 4 and 8 GB FC HBAs. changing dev_loss_tmo will no longer cause the user configured path tov to change. Also.0 Release Notes o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem Linux FC Driver Kit for HP Brocade HBAs and mezzanine HBAs Version: 3. Enhancements This is the first Drop of the Brocade Driver rpm Linux FC Driver Kit for HP Brocade HBAs and mezzanine HBAs Version: 3.06. user modifications of the I/O Interrupt Latency take effect immediately.0 (Recommended) 477 Fixes o The user configured path tov now persists across server reboots. Enhancements This is the first Drop of the Brocade Driver rpm Linux FC Driver Kit for HP Brocade HBAs and mezzanine HBAs Version: 3.2.1. HP | Service Pack for ProLiant 2014.0 (Recommended) Fixes o o o The user configured path tov now persists across server reboots.2. user modifications of the I/O Interrupt Latency take effect immediately.0 .HP Service Pack for ProLiant 2014. Also. changing dev_loss_tmo will no longer cause the user configured path tov to change.1.1.06. Enhanced Brocade Linux driver to handle multiple paths (Critical disks) to the KDUMP device during kernel dump with direct attach storage configurations. For Brocade 4 and 8 GB FC HBAs.2.0 (Recommended) Fixes o o o The user configured path tov now persists across server reboots. Also. changing dev_loss_tmo will no longer cause the user configured path tov to change. Enhanced Brocade Linux driver to handle multiple paths (Critical disks) to the KDUMP device during kernel dump with direct attach storage configurations. For Brocade 4 and 8 GB FC HBAs. Enhanced Brocade Linux driver to handle multiple paths (Critical disks) to the KDUMP device during kernel dump with direct attach storage configurations.0 (Recommended) Fixes o o o The user configured path tov now persists across server reboots. changing dev_loss_tmo will no longer cause the user configured path tov to change. user modifications of the I/O Interrupt Latency take effect immediately.1.2. user modifications of the I/O Interrupt Latency take effect immediately.0 Release Notes o o Enhanced Brocade Linux driver to handle multiple paths (Critical disks) to the KDUMP device during kernel dump with direct attach storage configurations. HBAs and mezzanine HBAs and CNAs Version: 8.33 (Recommended) Fixes HP | Service Pack for ProLiant 2014. user modifications of the I/O Interrupt Latency take effect immediately.1. For Brocade 4 and 8 GB FC HBAs.0 478 . Enhancements This is the first Drop of the Brocade Driver rpm Linux FC Driver Kit for HP Brocade HBAs and mezzanine HBAs Version: 3. For Brocade 4 and 8 GB FC HBAs.2.0 (Recommended) Fixes o o o The user configured path tov now persists across server reboots. Also.HP Service Pack for ProLiant 2014.06.2. Enhancements This is the first Drop of the Brocade Driver rpm Linux FC Driver Kit for HP Brocade HBAs and mezzanine HBAs Version: 3. Enhancements This is the first Drop of the Brocade Driver rpm Linux FCoE/FC Driver Kit for HP Emulex CNAs.06. changing dev_loss_tmo will no longer cause the user configured path tov to change.2. Enhanced Brocade Linux driver to handle multiple paths (Critical disks) to the KDUMP device during kernel dump with direct attach storage configurations. Also. HP | Service Pack for ProLiant 2014.0 Release Notes o o Corrected an issue with an incorrect FCP Priority value being detected for LUNs greater than 128. Enhancements o o Added support for Red Hat Enterprise 5 update 10 Added support for HP LPe1605 16Gb FC HBA for BladeSystem c-Class Supported Devices and Features o o o o o o o o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.2. Corrected an issue where a PCI function reset could not be performed when the adapter was in offline mode.33 (Recommended) 479 Fixes o Corrected an issue with an incorrect FCP Priority value being detected for LUNs greater than 128.2. HBAs and mezzanine HBAs and CNAs Version: 8.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter Linux FCoE/FC Driver Kit for HP Emulex CNAs.06.06.HP Service Pack for ProLiant 2014.0 . 0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2. Corrected an issue where a PCI function reset could not be performed when the adapter was in HP | Service Pack for ProLiant 2014.06.7. Enhancements o o Added support for Red Hat Enterprise 5 update 10 Added support for HP LPe1605 16Gb FC HBA for BladeSystem c-Class Supported Devices and Features o o o o o o o o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.39 (Recommended) Fixes 480 o o Corrected an issue with an incorrect FCP Priority value being detected for LUNs greater than 128.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter Linux FCoE/FC Driver Kit for HP Emulex CNAs. HBAs and mezzanine HBAs and CNAs Version: 8.3.0 .0 Release Notes o Corrected an issue where a PCI function reset could not be performed when the adapter was in offline mode.06.HP Service Pack for ProLiant 2014. Corrected an issue where a PCI function reset could not be performed when the adapter was in offline mode.HP Service Pack for ProLiant 2014.06.06.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter Linux FCoE/FC Driver Kit for HP Emulex CNAs.3.7. HBAs and mezzanine HBAs and CNAs Version: 8. Enhancements o o Added support for Red Hat Enterprise 6 update 5 Added support for HP LPe1605 16Gb FC HBA for BladeSystem c-Class Supported Devices and Features o o o o o o o o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2. HP | Service Pack for ProLiant 2014.0 Release Notes offline mode.0 .0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.39 (Recommended) Fixes o o 481 Corrected an issue with an incorrect FCP Priority value being detected for LUNs greater than 128. 7.06.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter Linux FCoE/FC Driver Kit for HP Emulex CNAs.06.0 Release Notes Enhancements o Added support for HP LPe1605 16Gb FC HBA for BladeSystem c-Class Supported Devices and Features o o o o o o o o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.3.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2. Corrected an issue where a PCI function reset could not be performed when the adapter was in offline mode.HP Service Pack for ProLiant 2014. Enhancements HP | Service Pack for ProLiant 2014. HBAs and mezzanine HBAs and CNAs Version: 8.0 482 .39 (Recommended) Fixes o o Corrected an issue with an incorrect FCP Priority value being detected for LUNs greater than 128. 6-k2-4 (Recommended) Important Note! HP StorageWorks QLogic Adapters Release Notes Enhancements Updated to version 8.0 483 .06.5.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter Linux FCoE/FC Driver Kit for HP Qlogic CNAs.HP Service Pack for ProLiant 2014.12.04.00.0 Release Notes o Added support for HP LPe1605 16Gb FC HBA for BladeSystem c-Class Supported Devices and Features o o o o o o o o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.00.04.6-k2-4 Linux FCoE/FC Driver Kit for HP Qlogic CNAs. HBAs and mezzanine HBAs Version: 8.06.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.5. HBAs and mezzanine HBAs Version: 8.6-k2-4 (Recommended) Important Note! HP StorageWorks QLogic Adapters Release Notes HP | Service Pack for ProLiant 2014.5.04.12.00.12. 0-k4 (Recommended) Important Note! HP StorageWorks QLogic Adapters Release Notes Fixes Fix lock-up issue when loading boot code under certain circumstances Enhancements Updated to 8.3-k4 (Recommended) Important Note! HP StorageWorks QLogic Adapters Release Notes Fixes Updated driver to load on a SLES 11 SP3 kernel errata (SLES 11 only) Enabled secure boot on SLES 11 SP3 Fix lock-up issue when loading boot code under certain circumstances Enhancements Updated to version 8.12.12.6-k2-4 Linux FCoE/FC Driver Kit for HP Qlogic CNAs.12.11.04.5.06.06.00.12.00.00. HBAs and mezzanine HBAs Version: 8.3-k4 Linux FCoE/FC Driver Kit for HP Qlogic CNAs.04.HP Service Pack for ProLiant 2014.0-k4 484 HP | Service Pack for ProLiant 2014.12.11.11.00.00.04.04.12. HBAs and mezzanine HBAs Version: 8.0 Release Notes Enhancements Updated to version 8.00.00. HBAs and mezzanine HBAs Version: 8.04.06.0 .11.3-k4 Linux FCoE/FC Driver Kit for HP Qlogic CNAs.06.3-k4 (Recommended) Important Note! HP StorageWorks QLogic Adapters Release Notes Fixes Updated driver to load on a SLES 11 SP3 kernel errata (SLES 11 only) Enabled secure boot on SLES 11 SP3 Fix lock-up issue when loading boot code under certain circumstances Enhancements Updated to version 8.04.12.04. 0.1 1.0 1.07.0.7.not supported Microsoft Windows Client Operating Systems Driver Description XP x86 Vista x86 Vista x64 7 x86 7 x64 8 x86 8 x64 HP LTO Tape Drive 1.0 1/8 Tape Library HP ESL E Tape Library * * * * * * * HP MSL6000 Series * * * * * * * Tape Library HP DAT Tape * * * * * * * Autoloader 8.7. 3.7.7.2 Server 2003 x64 Server 2003 IA64 Server 2008 x86 Server 2008 x64 Serve Server Server Server Server r 2008 2008 R2 2008 R2 2012 2012 IA64 x64 IA64 x64 R2 x64 1.7.0.0.3 1.2 1.2 HP DAT Tape Drive 1.7.2012 160 only) HP SDLT/VS Tape Drive * * * * * * * HP ESL G3 Tape Library * * * * * * * HP MSL6480.0.7.1.7. 0 HP | Service Pack for ProLiant 2014.3 * * * Microsoft Windows Server Operating Systems Driver 200 Server Descriptio 0 2003 n x86 x86 HP LTO (LTO6 not supporte d on IA64 ) HP DAT Tape Drive * 1.0.0.7.7.07.0.0.2.0. 2 485 * 1.2010 6.1.7.0 HP USB Mass Storage Controller .7.7.0.HP Service Pack for ProLiant 2014.2010 6.7.0.1 (x64) and Microsoft Windows Server 2012 R2 (x64) HP StoreEver MSL6480 supported with driver versions 3.7.2 1.2 1.2010 7.0 1.1 1.0 3.0 3.1 1.0.0.0.0 * * * 3.0.0 1.7.Storage Tape HP StoreEver Tape Drivers for Windows Version: 3.0 Release Notes Top Driver .1 1.9.0.1.0.0.7.2 1.06.1.6.0 3.1.0 1.1.06.7.7.1 x64 1.0 1.0.07.0 1.00.7.7.7.2 1.6.2.1.0.0 1.0 1. G3.0 .0.0 and above .0 1.0.0 1.0.2 1.7.07.1.0.1 1.0 3.0.0.new driver versions  * .6.0.0 3.0.0.0.1.3 1.7.0.0.7.1 1.(not available for IA64 operating systems) See table below for operating system support and driver versions  bold .0.0 3.0 1.0.2010 6.2012 7.2010 6.7.0 (Recommended) Enhancements o o o Added support and drivers for Microsoft Windows 8.0.7.7.0.1.07.(DAT 72 & 6.0.1.0.1.7.0.7.2 1.1.7.2 1.7.3 1.2 1.7.0 1.00. 3 1.06.07.0 * 1.0 7.1 7.2.0 3.07.0.1 7.0.0.201 7.0.1.0.7.0.0.1.2.2.0 * * * 1.2.5.5.9.7.1.2.1 7.1 * * 3.0.0.201 6.0.2. 2 * 3. G3.5.201 6.0 3.5.0 3.0.07.0.0.0 7.7.0 7.5.1 7.8.0.0.7.0. 3 * 1. 1/8 Tape Library HP ESL E Tape Library HP MSL6000 Series Tape Library HP DAT Tape Autoload er * 6.0 3.7.5.(DAT 72 & 160 only) HP SDLT/VS Tape Drive HP ESL G3 Tape Library HP MSL6480.1.5.9.1.1.2.0.0.1.0.3 1.07.0.2.0 1.0.0.1 7.System Management Combined Chipset Identifier for Windows Server 2008 Version: 8.07.5.7.3 1.201 0 0 0 0 0 0 0 0 2 * * 3.0 .3 1.0.0.5.5.5.0 3.0 1.0 3.0 * 1.0. 486 Combined Chipset Identifier for Windows Server 2008 R2 Version: 8.3 1.5. Enhancements Added support for new processor options on HP ProLiant Gen8 servers.0.201 6.2.0 3.2.0.0 3.0 3.2.0.0 * 1.0 1.2.0.1.0 3.0 3.0.7.07.9.0.5.201 6.201 6.0 3.7.0 (Optional) Important Note! Version 8.1.0 3.1.3 * * Top Driver .0 1.1.1.0 * * * * * * * * 7.0 1.0.3 1.0.0 (Optional) HP | Service Pack for ProLiant 2014.5.07.201 6.07.HP Service Pack for ProLiant 2014.8.0 Release Notes HP USB Mass Storage Controller .1 7.1.0.1.5.0.201 6.06.5.0 of this component is the final version to support installation under Windows Server 2003.0 3.2.3 1.00.0 3.0.1. Combined Chipset Identifier for Windows Server 2012 Version: 8.HP Service Pack for ProLiant 2014. you don't need to install this package.0 (Optional) Important Note! Version 8. This was expected messages as probe was done during the init.06.g. HP OpenIPMI Device Driver for Red Hat Enterprise Linux 5 (AMD64/EM64T) Version: 8.0.2. Prerequisites The Linux kernel ".0. This is not the default on some older Linux distributions.0. Combined Chipset Identifier for Windows Server 2008 x64 Edition Version: 8.5. Enhancements Added support for new processor options on HP ProLiant Gen8 servers.1.0 Release Notes Enhancements Added support for new processor options on HP ProLiant Gen8 servers. Error messages will be displayed during the rebuild process indicating which Linux packages are missing. Therefore.config" file must have IPMI support enabled for rebuilds. Fixes o Suppressed logs where " channel_handler:Error Code: 0xc9" message was observed in /var/log/messages. you don't need to install this package.0 . HP OpenIPMI Device Driver for Red Hat Enterprise Linux 5 (x86) 487 Version: 8.5. an errata kernel) is used in place of the supported version of Linux.2.2-*. the standard Linux Kernel build environment will need to be installed.06. Therefore.2-*.0 of this component is the final version to support installation under Windows Server 2003 x64 Edition.0 (A) (Optional) Enhancements Enable installation under Windows Server 2012 R2. HP | Service Pack for ProLiant 2014.rhel5 (Optional) Important Note! The HP OpenIPMI device driver features are now available in the Red Hat Enterprise Linux 5 Update 5 (or Later) Kernel.rhel5 (Optional) Important Note! The HP OpenIPMI device driver features are now available in the Red Hat Enterprise Linux 5 Update 5 (or Later) Kernel. If a different Linux kernel (e. 0.0. If a different Linux kernel (e.06.0 (C) (Optional) Enhancements Add support for Microsoft Windows Server 2012 R2 on selected HP ProLiant G6 servers. Error messages will be displayed during the rebuild process indicating which Linux packages are missing.14.0.15.0 (Optional) HP | Service Pack for ProLiant 2014.g.10. HP ProLiant iLO 2 Management Controller Driver for Windows Server 2012 Version: 1. This is not the default on some older Linux distributions.config" file must have IPMI support enabled for rebuilds.0 488 .0 (Recommended) Fixes Corrected command timeout failures reported by the driver when communicating with iLO 2.06.1.0 (Optional) Fixes Added identifiers for additional devices that appear in Windows Device Manager when Intel Performance Counter Monitor is enabled through the BIOS/Platform Configuration (RBSU) on the HP ProLiant DL580 Gen8.0. Fixes o Suppressed logs where " channel_handler:Error Code: 0xc9" message was observed in /var/log/messages. HP ProLiant iLO 2 Management Controller Driver for Windows Server 2008 x64 Editions Version: 1. the standard Linux Kernel build environment will need to be installed. HP ProLiant iLO 2 Management Controller Driver for Windows Server 2008 Version: 1.14.0 Release Notes Prerequisites The Linux kernel ". HP ProLiant Gen8 Supplemental Chipset Identifier for Windows Version: 1. HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64 Version: 3. an errata kernel) is used in place of the supported version of Linux. This was expected messages as probe was done during the init.0 (Recommended) Fixes Corrected command timeout failures reported by the driver when communicating with iLO 2.0.HP Service Pack for ProLiant 2014. Previously. Fixes Ensure the closing "</RIBCL>" tag is returned when the input RIBCL script contains the "<?xmlilo outputformat="xml"?>" tag.9.06.00 was released.0 (B) (Optional) Prerequisites 489 The HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64 (version 3.0.10. but is now installed separately.HP Service Pack for ProLiant 2014.0 Release Notes Important Note! The Channel Interface Driver was separated into its own component when the ProLiant Support Pack version 9.4. the driver was a part of the iLO 3 Management Controller Driver Package component.0 or later) must be installed prior to this component.4.0 (Optional) Prerequisites The HP ProLiant iLO 3/4 Channel Interface Driver for Windows X86 (version 3.0.0.00 was released. Previously.9. HP ProLiant iLO 3/4 Channel Interface Driver for Windows X86 Version: 3. the driver was a part of the iLO 3 Management Controller Driver Package component. but is now installed separately. Fixes Ensure the closing "</RIBCL>" tag is returned when the input RIBCL script contains the "<?xmlilo outputformat="xml"?>" tag.0 (Optional) Important Note! The Channel Interface Driver was separated into its own component when the ProLiant Support Pack version 9.0. HP ProLiant iLO 3/4 Management Controller Driver Package for Windows Server 2008/2012 X64 Version: 3.0 . The Channel Interface Driver was previously included within this component.0.0 or later) must be installed prior to this component. The Channel Interface Driver was previously included within this component. Fixes Corrected reporting of the memory size available to Windows when Advanced Memory Protection is configured for Online Spare mode. HP ProLiant iLO 3/4 Management Controller Driver Package for Windows Server 2008 X86 Version: 3. HP | Service Pack for ProLiant 2014.06. 6748 (Optional) Enhancements Enhanced component-level logging has been implemented in the Smart Component installer.0 Drivers for Windows Server 2008 R2 Version: 3.0 (Optional) Enhancements Initial release. HP | Service Pack for ProLiant 2014.0.23. USB Host Controller Identifier for Windows Server 2008 x64 Edition Version: 1.HP Service Pack for ProLiant 2014.0.06.14. USB Host Controller Identifier for Windows Server 2008 Version: 1.0.0 Drivers for Windows Server 2008 R2 Version: 2.06.19 (Optional) Enhancements Initial release.0 (Optional) Enhancements Initial release. Top Driver .Video ATI ES1000 Video Controller Driver for Windows Server 2008 Version: 6. The generated log file will be located on the target system in the %SystemRoot%\cpqsystem\log directory under the name CPQSETUP. Renesas Electronics USB 3.0.5.LOG.10.0 490 .0 (Optional) Enhancements Initial release. Top Driver .0 Release Notes Enhancements Enable installation under Windows Server 2012 R2.0.0.USB Intel USB 3. Matrox G200eH Video Controller Driver for Windows Server 2008 X86 Version: 6. Enhancements Add support for Windows Server 2012 R2.06.45 of this driver is installed.6748 (Optional) Enhancements o o Added support for Microsoft Windows Server 2008 R2.1030 (Optional) Fixes o o o Removed support for EDID 2. Hardened the detailed timings algorithm to prevent a possible division by zero.06. Removed 1024x768x43Hz from the supported resolution list.HP Service Pack for ProLiant 2014.1030 (Optional) Fixes o o o Removed support for EDID 2.12.102 (Optional) Fixes Corrected an issue with the mouse pointer not being visible in the Microsoft Desktop Duplication application when version 9.14. Matrox G200eH Video Controller Driver for Windows Server 2008 X64 Version: 6.0 Release Notes ATI ES1000 Video Controller Driver for Windows Server 2008 x64 Editions Version: 6. Matrox G200eH Video Controller Driver for Windows Server 2012 and Server 2012 R2 Version: 9. 491 HP | Service Pack for ProLiant 2014.LOG.1. The generated log file will be located on the target system in the %SystemRoot%\cpqsystem\log directory under the name CPQSETUP. Removed 1024x768x43Hz from the supported resolution list.10.15.0.0 . Hardened the detailed timings algorithm to prevent a possible division by zero.1.1.12.15.1. Enhanced component-level logging has been implemented in the Smart Component installer.0. 20 component and contains the same VC 4.hp.20 (b) (Critical) Important Note! The VC 4.0 (Optional) Enhancements Enhancements/New Features: o The HP 3Gb SAS Switch will now publish external IP addresses to Onboard Administrator versions 3.jsp?contentType=SupportM anual&lang=en&cc=us&docIndexId=64180&taskId=135&prodTypeId=3709945&prodSeriesId=4144084 492 Supported Devices and Features HP 10/10Gb Virtual Connect Ethernet Module for c-Class BladeSystem HP | Service Pack for ProLiant 2014.0 .17.20b component contains the VC 4.10 or earlier.06.jsp?contentType=SupportM anual&lang=en&cc=us&docIndexId=64180&taskId=135&prodTypeId=3709945&prodSeriesId=4144084 Fixes The latest list of issues resolved can be found in the HP Virtual Connect Release Notes that can be found in the "User guide" section of the following URL: http://h20000.com/bizsupport/TechSupport/DocumentIndex. Ethernet plus 4/8Gb 20port and 8Gb 24-port FC Edition Component for Windows Version: 4. The VC 4.HP Service Pack for ProLiant 2014. The only modification to the VC 4.www2. The vulnerability affects only the installer and was only present during the firmware upgrade process.20b component is for customers upgrading from VC 4.20b component replaces the previous VC 4.Blade Infrastructure HP 3Gb SAS BL Switch Firmware Smart Component for Linux Version: 2. VC firmware is not vulnerable to CVE-2014-0160.20 firmware image for HP BladeSystem c-Class Virtual Connect modules.com/bizsupport/TechSupport/DocumentIndex.20 firmware image contained in the previous VC 4.0 Release Notes Top Firmware .06.20 release. Prerequisites The latest version of HP Virtual Connect Release Notes contains the prerequisites and can also be found in the "User guide" section in the following URL: http://h20000.20 or later instead of the internal IP address. HP BladeSystem c-Class Virtual Connect Firmware. The VC 4. There is no vulnerability after the firmware upgrade has completed.2.www2.hp.20b component is an update to the installer component that was vulnerable to CVE-2014-0160. jsp?contentType=SupportM anual&lang=en&cc=us&docIndexId=64180&taskId=135&prodTypeId=3709945&prodSeriesId=4144084 Supported Devices and Features HP 10/10Gb Virtual Connect Ethernet Module for c-Class BladeSystem 493 HP Virtual Connect FlexFabric 10Gb/24-port Module for c-Class BladeSystem HP | Service Pack for ProLiant 2014. VC firmware is not vulnerable to CVE-2014-0160.06. The only modification to the VC 4.20b component is an update to the installer component that was vulnerable to CVE-2014-0160.20 release.20b component contains the VC 4.20 firmware image for HP BladeSystem c-Class Virtual Connect modules.20 firmware image contained in the previous VC 4. Prerequisites The latest version of HP Virtual Connect Release Notes contains the prerequisites and can also be found in the "User guide" section in the following URL: http://h20000.www2.hp. The VC 4.20 (b) (Critical) Important Note! The VC 4.20b component is for customers upgrading from VC 4.20b component replaces the previous VC 4. Ethernet plus 4/8Gb 20port and 8Gb 24-port FC Edition Component for Linux Version: 4.20 component and contains the same VC 4. The vulnerability affects only the installer and was only present during the firmware upgrade process.www2.10 or earlier. There is no vulnerability after the firmware upgrade has completed. The VC 4.06.hp.com/bizsupport/TechSupport/DocumentIndex.0 .0 Release Notes HP Virtual Connect FlexFabric 10Gb/24-port Module for c-Class BladeSystem HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem HP Virtual Connect Flex-10/10D Module for c-Class BladeSystem HP Virtual Connect FlexFabric-20/40 F8 Module for HP BladeSystem c-Class HP BladeSystem c-Class Virtual Connect Firmware.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=SupportM anual&lang=en&cc=us&docIndexId=64180&taskId=135&prodTypeId=3709945&prodSeriesId=4144084 Fixes The latest list of issues resolved can be found in the HP Virtual Connect Release Notes that can be found in the "User guide" section of the following URL: http://h20000.HP Service Pack for ProLiant 2014. 0 494 .38 HP P2000 MSA Array System.60 HP D6000 Disk Enclosure.06.1.17. Enhancements HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. Minimum Recommended Version o o o o o o o HP D3600/D3700 Disk Enclosure. Online HP 6Gb SAS BL Switch Firmware Smart Component for Linux Version: 4.0 Release Notes HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem HP Virtual Connect Flex-10/10D Module for c-Class BladeSystem HP Virtual Connect FlexFabric-20/40 F8 Module for HP BladeSystem c-Class Online HP 3Gb SAS BL Switch Firmware Smart Component for Windows Version: 2.0: Device. 0147 HP 600 Modular Disk System. 2. 3.0. 5. Fixed a rare issue where repeatedly rebooting the switch may cause some drives in the storage enclosure to not be detected.0 (Optional) Enhancements Enhancements/New Features: o The HP 3Gb SAS Switch will now publish external IP addresses to Onboard Administrator versions 3.1.06.00 HP D2600/D2700 Disk Enclosure. 3.0 (Recommended) Fixes Firmware Dependency: The devices listed below require minimum FW deliverables with HP Storage Manager version 4.54 Problems Fixed: o o Fixed issue in which the “Create and Assign Zone Group” operation did not display an error message if the required zone group name was blank.20 or later instead of the internal IP address.0.2.70 HP Smart Array P721m Controller. TS230P06 HP Smart Array P711m/P712m Controller. 1. 54 Problems Fixed: o o Fixed issue in which the “Create and Assign Zone Group” operation did not display an error message if the required zone group name was blank.Users should update to OA 4.0 Release Notes Enhancements/New Features: o Added support for the HP MSA 2040 Storage System. Enhancements Enhancements/New Features: o Added support for the HP MSA 2040 Storage System. Fixed a rare issue where repeatedly rebooting the switch may cause some drives in the storage enclosure to not be detected.22 if their system is using OA 4.20 is no longer available on the web and has been replaced with OA 4. 2.1.1.22. o OA 4. OA 4.22 HP | Service Pack for ProLiant 2014. Online HP 6Gb SAS BL Switch Firmware Smart Component for Windows Version: 4.06.22 if their system is using an OA version prior to OA 4.60 HP D6000 Disk Enclosure.06. Optional – Users should update to OA 4.0: Device.20 or 4.21.12 and is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version. 0147 HP 600 Modular Disk System.38 HP P2000 MSA Array System.0.HP Service Pack for ProLiant 2014.0 495 .00 HP D2600/D2700 Disk Enclosure.0. 3.0 (Recommended) Fixes Firmware Dependency: The devices listed below require minimum FW deliverables with HP Storage Manager version 4. Minimum Recommended Version o o o o o o o HP D3600/D3700 Disk Enclosure. 3. 5.70 HP Smart Array P721m Controller.22 (Recommended) Important Note! Recommended . 1. TS230P06 HP Smart Array P711m/P712m Controller. Online HP BladeSystem c-Class Onboard Administrator Firmware Component for Linux Version: 4. 71 has received FIPS 140-1 Certification http://csrc.Users should update to OA 4.22 includes fix for CVE 2014-0224 and also includes fix provided in OA 4.21 for CVE 2014-0160.HP Service Pack for ProLiant 2014.20 or 4.06. FIPS  OA 3.gov/groups/STM/cmvp/documents/1401/1401val2014.06. Optional – Users should update to OA 4.org/news/secadv_20140605. See Fixes Tab for more information. FIPS  OA 3.20 is no longer available on the web and has been replaced with OA 4.nist.0 Release Notes o includes fix for CVE 2014-0224 and also includes fix provided in OA 4.22 if their system is using OA 4.nist.22. OA 4.12 and is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.htm#2174 Prerequisites The Onboard Administrator smart component requires the client to ensure that the 32 bit compatibility libraries are install on a 64bit Linux Operating System Fixes Patched the support for SSL/TLS MITM Vulnerability CVE-20140224 http://www. See Fixes Tab for more information.0 .gov/groups/STM/cmvp/documents/1401/1401val2014. o o OA 4.txt Online HP BladeSystem c-Class Onboard Administrator Firmware Component for Windows Version: 4.21.22 if their system is using an OA version prior to OA 4.openssl.22 (Recommended) Important Note! Recommended .71 has received FIPS 140-1 Certification http://csrc.21 for CVE 2014-0160.org/news/secadv_20140605.htm#2174 Prerequisites The Onboard Administrator smart component requires the client to ensure that the 32 bit compatibility libraries are install on a 64bit Linux Operating System Fixes Patched the support for SSL/TLS MITM Vulnerability CVE-20140224 http://www.openssl.txt 496 HP | Service Pack for ProLiant 2014. iLO 2 might authenticate users with incorrect passwords when it is configured with Linux LDAP. System Programmable Logic Device upgrades might fail on BL465 G7 servers.  Note: iLO 2 is not vulnerable to the HeartBleed OpenSSL bug because the iLO 2 RSA SSLC library does not support the TLS Heartbeat extension. and RIBCL now matches iLO 3 reporting. iLO 3 v1.20 must upgrade v1.HP Service Pack for ProLiant 2014.20 may be obtained from the following FTP locations: Linux: ftp://ftp.hp. CLI. iLO might incorrectly report an insufficient fan solution. iLO 3 1. This caused iLO 3 to be HP | Service Pack for ProLiant 2014.0 497 .Lights-Out Management Firmware CD Supplemental Update / Online ROM Flash Component for Linux HP Integrated Lights-Out 2 Version: 2. Hard drive status reporting in the iLO web interface.06. The SNTP settings are not displayed in the iLO web interface after updating the firmware to iLO 3 1.50 and later does not send ARP before replying to a ping request.0 Release Notes Top Firmware . Firmware CD Supplemental Update / Online ROM Flash Component for Linux HP Integrated Lights-Out 3 Version: 1.23 was removed as it caused problems when an ISO is mounted on Windows systems.06. Solaris 10 and 11 cannot be installed by using Virtual Media. Serial Over LAN sessions might fail to establish when Windows is loading.70 (Optional) Prerequisites Customers running a version of iLO 3 previous to v1.hp.com/pub/softlib2/software1/sc-linux-fw-ilo/p1255562964/v64722 Windows: ftp://ftp.61.com/pub/softlib2/software1/sc-windows-fw-ilo/p1728391553/v64720 Fixes o o o o o o o o o o o The FreeIPMI tool "ipmi-power identify-status" command returns the value "unknown". HDD status is reported incorrectly when a p410i card is removed.25 (Recommended) Fixes o o o o o iLO 2 might stop responding after security scanners run the Heartbleed OpenSSL bug detection scan. Virtual CD/DVD-ROMs fail to mount in SLES 11 SP3.20 before upgrading to this version.com/pub/softlib2/software1/sc-windows-fw-ilo/p901462262/v64721 Win64: ftp://ftp. iLO fails to locate a valid image when an iLO firmware update is attempted via the CLI.hp. The SCSI command 0x51 (GET DISC INFORMATION) added in version 2. Updating the serial number of the server in BIOS does not update the FRU data. The Integrated Remote Console could fail to launch with Internet Explorer 11. SSL/TLS MITM. Fixes 1." . 1. Improved Java IRC.51 (Critical) Important Note! Intermittent Non-Maskable Interrupt (NMI) Events May Occur on HP ProLiant Gen8 Servers running HP Integrated Lights-Out 4 Firmware Versions 1.If you create a disk image when Virtual Media is mounted in the Java IRC.0 498 . . .40 and 1. Virtual Media can be disconnected by ejecting it from the OS. .Time zones that are south of the Equator and use DST are handled incorrectly.06.  HP will release additional communications as new information becomes available.0 Release Notes o unreachable to pings from clients with teamed NICs. an invalid message is displayed.When using the Java IRC in Linux.The Windows Server 2008 or 2012 installer might fail with the following error message when used with Virtual Media on iLO 4 1. c-Class Blades might request max power when the server is powered on.51 Fixes: .50.An incomplete Japanese message is displayed in the Set to factory defaults interface when the Japanese Language Pack is loaded. Enhancements o o o IPv6 support for Scriptable Virtual Media.40.30.32.  Please subscribe to HP Subscriber’s Choice to receive these documents proactively. some characters cannot be entered from a Japanese keyboard when the Japanese layout is selected.9. .Intermittent Non-Maskable Interrupt (NMI) Events May Occur on HP ProLiant Gen8 Servers running HP Integrated Lights-Out 4 Firmware Versions 1.32 and 1.40: “A required CD/DVD drive device driver is missing. Firmware CD Supplemental Update / Online ROM Flash Component for Linux HP Integrated Lights-Out 4 Version: 1. . 1. 1.32.30.06. . .Auto Power On does not work on server blades after upgrading to iLO 4 v1.Random "Embedded Flash/SD-CARD: Failed restart" errors appear in the iLO 4 Event Log after server shutdown. .SSH keys cannot be imported by using XML after upgrading to iLO 4 v1.40 and 1.iLO might stop responding if the DNS server fails to respond when iLO is trying to log multiple entries that require DNS reverse lookup. o o o Please note that this product includes a derivative OpenSSL 0.HP Service Pack for ProLiant 2014. 1. HP | Service Pack for ProLiant 2014.50.The keyboard doesn't work when you use the Java IRC to mount an image file through a URL. 1.8e and is under investigation to determine whether there is any impact of OpenSSL Vulnerability CVE-2014-0224 .50 Fixes: .40. .iLO Virtual Media CD-ROM connect says “ok” when http://name is unreachable.06.Multiple iLO Federation Management groups cannot be deleted in a certain order.Added an SNMP trap for Uncorrectable Machine Check Error.Multicast replies display an incorrect iLO version number.50 Fixes: . Firmware CD Supplemental Update / Online ROM Flash Component for VMware ESXi . .30. . . 1. .40.SSH keys cannot be imported by using XML after upgrading to iLO 4 v1.40.40 and 1. 1.Intermittent Non-Maskable Interrupt (NMI) Events May Occur on HP ProLiant Gen8 Servers running HP Integrated Lights-Out 4 Firmware Versions 1. . .iLO WEB page could stop responding after a firmware update via the group firmware update in iLO Federation Management.iLO does not always respond to multicast M-SEARCH requests.50 Enhancements: . .51 Fixes: .  HP will release additional communications as new information becomes available.Implemented significant performance improvements in iLO Federation Management queries.9.  Please subscribe to HP Subscriber’s Choice to receive these documents proactively. .Auto Power On does not work on server blades after upgrading to iLO 4 v1. Enhancements 1.40 and 1.iLO requires a reset when the IPv6 Multicast Scope is changed for iLO Federation discovery.Added the ability for iLO to get Domain name to Get or Display from DHCPv6 server. .The SERVER_POST_STATE element is missing from RIBCL output. 1.EBIPA IPv6 settings not always updated on iLO when iLO DHCP IPv4 is disabled.50.0 Release Notes .0 499 . .51 (Critical) Important Note! Intermittent Non-Maskable Interrupt (NMI) Events May Occur on HP ProLiant Gen8 Servers running HP Integrated Lights-Out 4 Firmware Versions 1. 1. o o o Please note that this product includes a derivative OpenSSL 0. Fixes 1.HP Service Pack for ProLiant 2014.30.SSL/TLS MITM.06. . 1.HP Integrated Lights-Out 4 Version: 1.32.50. HP | Service Pack for ProLiant 2014.8e and is under investigation to determine whether there is any impact of OpenSSL Vulnerability CVE-2014-0224 .AlertMail implementation is inconsistent between the iLO web interface and the CLI.32.Menu and Title area return to English characters when the Japanese Language Pack is loaded. " .Random "Embedded Flash/SD-CARD: Failed restart" errors appear in the iLO 4 Event Log after server shutdown.70 (Optional) Prerequisites Customers running a version of iLO 3 previous to v1.The Windows Server 2008 or 2012 installer might fail with the following error message when used with Virtual Media on iLO 4 1.20 may be obtained from the following FTP locations: Linux: ftp://ftp.0 Release Notes . Firmware CD Supplemental Update / Online ROM Flash Component for VMware ESXi .When using the Java IRC in Linux.iLO Virtual Media CD-ROM connect says “ok” when http://name is unreachable.HP Integrated Lights-Out 3 Version: 1.06. .06.If you create a disk image when Virtual Media is mounted in the Java IRC. .iLO does not always respond to multicast M-SEARCH requests.hp. . .AlertMail implementation is inconsistent between the iLO web interface and the CLI.iLO requires a reset when the IPv6 Multicast Scope is changed for iLO Federation discovery.20 before upgrading to this version. iLO 3 v1. .com/pub/softlib2/software1/sc-windows-fw-ilo/p1728391553/v64720 HP | Service Pack for ProLiant 2014. .hp. . .Menu and Title area return to English characters when the Japanese Language Pack is loaded.20 must upgrade v1.50 Enhancements: .40: “A required CD/DVD drive device driver is missing. .iLO WEB page could stop responding after a firmware update via the group firmware update in iLO Federation Management.32 and 1.Multicast replies display an incorrect iLO version number.Added an SNMP trap for Uncorrectable Machine Check Error. .EBIPA IPv6 settings not always updated on iLO when iLO DHCP IPv4 is disabled. .HP Service Pack for ProLiant 2014. .hp. an invalid message is displayed.0 500 . .Added the ability for iLO to get Domain name to Get or Display from DHCPv6 server.Implemented significant performance improvements in iLO Federation Management queries.Multiple iLO Federation Management groups cannot be deleted in a certain order. . . Enhancements 1.com/pub/softlib2/software1/sc-linux-fw-ilo/p1255562964/v64722 Windows: ftp://ftp. .com/pub/softlib2/software1/sc-windows-fw-ilo/p901462262/v64721 Win64: ftp://ftp.iLO might stop responding if the DNS server fails to respond when iLO is trying to log multiple entries that require DNS reverse lookup.An incomplete Japanese message is displayed in the Set to factory defaults interface when the Japanese Language Pack is loaded.The keyboard doesn't work when you use the Java IRC to mount an image file through a URL. . some characters cannot be entered from a Japanese keyboard when the Japanese layout is selected.The SERVER_POST_STATE element is missing from RIBCL output.Time zones that are south of the Equator and use DST are handled incorrectly. . System Programmable Logic Device upgrades might fail on BL465 G7 servers. Virtual CD/DVD-ROMs fail to mount in SLES 11 SP3.25 (Recommended) Fixes o o o o o iLO 2 might stop responding after security scanners run the Heartbleed OpenSSL bug detection scan.HP Integrated Lights-Out 3 Version: 1.0 Release Notes Fixes o o o o o o o o o o o o The FreeIPMI tool "ipmi-power identify-status" command returns the value "unknown".06. Improved Java IRC. c-Class Blades might request max power when the server is powered on. Updating the serial number of the server in BIOS does not update the FRU data.0 501 . Online ROM Flash Component for Windows . Enhancements o o o IPv6 support for Scriptable Virtual Media. The SNTP settings are not displayed in the iLO web interface after updating the firmware to iLO 3 1. Hard drive status reporting in the iLO web interface. The SCSI command 0x51 (GET DISC INFORMATION) added in version 2.HP Integrated Lights-Out 2 Version: 2. CLI. iLO might incorrectly report an insufficient fan solution. Virtual Media can be disconnected by ejecting it from the OS.HP Service Pack for ProLiant 2014. Online ROM Flash Component for Windows . Serial Over LAN sessions might fail to establish when Windows is loading. and RIBCL now matches iLO 3 reporting.23 was removed as it caused problems when an ISO is mounted on Windows systems.50 and later does not send ARP before replying to a ping request. iLO fails to locate a valid image when an iLO firmware update is attempted via the CLI. The Integrated Remote Console could fail to launch with Internet Explorer 11.61. Solaris 10 and 11 cannot be installed by using Virtual Media.70 (Optional) Prerequisites Customers running a version of iLO 3 previous to v1.  Note: iLO 2 is not vulnerable to the HeartBleed OpenSSL bug because the iLO 2 RSA SSLC library does not support the TLS Heartbeat extension. iLO 2 might authenticate users with incorrect passwords when it is configured with Linux LDAP. iLO 3 1.20 must upgrade v1. HDD status is reported incorrectly when a p410i card is removed.06. This caused iLO 3 to be unreachable to pings from clients with teamed NICs.20 before upgrading to this HP | Service Pack for ProLiant 2014. iLO 3 1. The SNTP settings are not displayed in the iLO web interface after updating the firmware to iLO 3 1.61. Updating the serial number of the server in BIOS does not update the FRU data.30.8e and is under investigation to determine whether there is any impact of OpenSSL Vulnerability CVE-2014-0224 . Virtual Media can be disconnected by ejecting it from the OS.com/pub/softlib2/software1/sc-linux-fw-ilo/p1255562964/v64722 Windows: ftp://ftp.hp.32. Virtual CD/DVD-ROMs fail to mount in SLES 11 SP3. c-Class Blades might request max power when the server is powered on.20 may be obtained from the following FTP locations: Linux: ftp://ftp. This caused iLO 3 to be unreachable to pings from clients with teamed NICs. Solaris 10 and 11 cannot be installed by using Virtual Media. iLO might incorrectly report an insufficient fan solution. Prerequisites The addition of IPv6 support for iLO scripting interfaces requires the use of new versions of several iLO utilities. o o o Please note that this product includes a derivative OpenSSL 0.com/pub/softlib2/software1/sc-windows-fw-ilo/p901462262/v64721 Win64: ftp://ftp.HP Integrated Lights-Out 4 Version: 1.0 502 .40 and 1. System Programmable Logic Device upgrades might fail on BL465 G7 servers. HDD status is reported incorrectly when a p410i card is removed. iLO 3 v1.SSL/TLS MITM. iLO fails to locate a valid image when an iLO firmware update is attempted via the CLI.hp.51 (Critical) Important Note! Intermittent Non-Maskable Interrupt (NMI) Events May Occur on HP ProLiant Gen8 Servers running HP Integrated Lights-Out 4 Firmware Versions 1. Improved Java IRC.06.9.com/pub/softlib2/software1/sc-windows-fw-ilo/p1728391553/v64720 Fixes o o o o o o o o o o o o The FreeIPMI tool "ipmi-power identify-status" command returns the value "unknown".06. 1. Online ROM Flash Component for Windows .50. 1.0 Release Notes version.50 and later does not send ARP before replying to a ping request. Customers using previous versions of these utilities must upgrade to the new versions: HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.hp.  HP will release additional communications as new information becomes available. Serial Over LAN sessions might fail to establish when Windows is loading.  Please subscribe to HP Subscriber’s Choice to receive these documents proactively. Enhancements o o o IPv6 support for Scriptable Virtual Media. Auto Power On does not work on server blades after upgrading to iLO 4 v1.HPQLOCFG 1. 1." .Added the ability for iLO to get Domain name to Get or Display from DHCPv6 HP | Service Pack for ProLiant 2014.40: “A required CD/DVD drive device driver is missing. some characters cannot be entered from a Japanese keyboard when the Japanese layout is selected.PL 4. .40. .Random "Embedded Flash/SD-CARD: Failed restart" errors appear in the iLO 4 Event Log after server shutdown.Menu and Title area return to English characters when the Japanese Language Pack is loaded.Multicast replies display an incorrect iLO version number.50.When using the Java IRC in Linux.HPLOMIG 4.50 Fixes: .0 . . . .iLO requires a reset when the IPv6 Multicast Scope is changed for iLO Federation discovery.06.The keyboard doesn't work when you use the Java IRC to mount an image file through a URL. .30.EBIPA IPv6 settings not always updated on iLO when iLO DHCP IPv4 is disabled. .0 (upgrade HPLOMIG before installing this version of iLO 4) Fixes 1. .Time zones that are south of the Equator and use DST are handled incorrectly.SSH keys cannot be imported by using XML after upgrading to iLO 4 v1. .iLO Virtual Media CD-ROM connect says “ok” when http://name is unreachable. an invalid message is displayed. .1 (replaces CPQLOCFG) . . . 1. 1.3.0 503 .40. . .If you create a disk image when Virtual Media is mounted in the Java IRC.LOCFG.06.iLO WEB page could stop responding after a firmware update via the group firmware update in iLO Federation Management.3.The SERVER_POST_STATE element is missing from RIBCL output.AlertMail implementation is inconsistent between the iLO web interface and the CLI.0 bundle) .32.The Windows Server 2008 or 2012 installer might fail with the following error message when used with Virtual Media on iLO 4 1.20 (included in the HP Lights-Out XML Scripting Sample 4. .Added an SNMP trap for Uncorrectable Machine Check Error. .Multiple iLO Federation Management groups cannot be deleted in a certain order.Intermittent Non-Maskable Interrupt (NMI) Events May Occur on HP ProLiant Gen8 Servers running HP Integrated Lights-Out 4 Firmware Versions 1.32 and 1.40 and 1.HPONCFG 4.0 bundle .iLO might stop responding if the DNS server fails to respond when iLO is trying to log multiple entries that require DNS reverse lookup.HP Service Pack for ProLiant 2014. .3.An incomplete Japanese message is displayed in the Set to factory defaults interface when the Japanese Language Pack is loaded.50 Enhancements: .HP Lights-Out XML Scripting Sample 4. .51 Fixes: . . Enhancements 1.3.0 Release Notes .iLO does not always respond to multicast M-SEARCH requests. 02).15 (D) (Optional) Prerequisites This package requires that the appropriate driver for your device be installed before the firmware can be updated.Network HP QLogic P3 Online Firmware Upgrade Utility for Windows Server x64 Editions Version: 4. Enhancements The component tools in this component have been updated to include translations for Simplified Chinese. . This firmware is part of a combo image file p3p26002.0. Supported Devices and Features This software supports the following HP QLogic P3 network adapters: o o o o o HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic P3P Online Firmware Upgrade Utility for Windows Server x64 Editions Version: 4.14.0. The component tools in this component have been updated to properly identify Windows Server 2012 R2.06.26.Implemented significant performance improvements in iLO Federation Management queries. Enhancements This component provides firmware version 4.60. Top Firmware . 504 Supported Devices and Features This software package supports the following HP P3P network adapters: o HP CN1000Q Dual Port Converged Network Adapter HP | Service Pack for ProLiant 2014.06.0 Release Notes server.0.16 (Optional) Fixes This component corrects an issue where the flash engine may cause an application crash during execution in Japanese language OSes.0.bin (v2.HP Service Pack for ProLiant 2014.0 . 18 (Optional) Prerequisites This package requires the appropriate HP Broadcom driver for VMware for your device to be installed before firmware can be updated.x Version: 1.0 Release Notes o o HP NC523SFP 10Gb 2-port Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP Broadcom Online Firmware Upgrade Utility for Linux x86 Version: 2. Enhancements This product now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter 505 HP | Service Pack for ProLiant 2014. Enhancements This product now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP Broadcom Online Firmware Upgrade Utility for VMware 5. Enhancements This product now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP Broadcom Online Firmware Upgrade Utility for Linux x86_64 Version: 2.20 (Optional) Prerequisites This package requires the appropriate driver for your adapter be installed before firmware can be updated.06.11.20 (Optional) Prerequisites This package requires the appropriate driver for your network adapter be installed before firmware can be updated.06.2.HP Service Pack for ProLiant 2014.11.0 . HP Service Pack for ProLiant 2014. Enhancements This component now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP Broadcom Online Firmware Upgrade Utility for Windows Server x64 Editions Version: 4. This component addresses an issue that resulted in sideband communication transmitting from the wrong HP | Service Pack for ProLiant 2014.com and does not necessarily indicate the precedence of the content of the component. The date listed with the component indicates the date that the component was made available on hp. even though the previous version of this component has a later date. even though the previous version of this component has a later date.0 Release Notes HP Broadcom Online Firmware Upgrade Utility for Windows Server 2008 Version: 4.19 (Optional) Fixes This component addresses an issue which prevented correct operation on the HP Ethernet 1Gb 1-port 364i Adapter.5.06.06.0. Prerequisites This package requires the appropriate driver for your NIC be installed before firmware can be updated.32 (B) (Optional) Important Note! Note that this component contains newer firmware than the previous version.0 506 . The date listed with the component indicates the date that the component was made available on hp.0. Enhancements This component now supports the following network adapters: o o HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP Intel Online Firmware Upgrade Utility for Linux x86 Version: 1.0.32 (B) (Optional) Important Note! Note that this component contains newer firmware than the previous version.com and does not necessarily indicate the precedence of the content of the component. Prerequisites This package requires the appropriate driver for your NIC be installed before firmware can be updated.0. 06.5.0 . Supported Devices and Features This package supports the following network adapters: o o o o o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel Online Firmware Upgrade Utility for Linux x86_64 Version: 1. Supported Devices and Features This package supports the following network adapters: o o o o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter 507 HP | Service Pack for ProLiant 2014. This component addresses an issue that resulted in sideband communication transmitting from the wrong port.0 Release Notes port.HP Service Pack for ProLiant 2014.06.19 (Optional) Fixes This component addresses an issue which prevented correct operation on the HP Ethernet 1Gb 1-port 364i Adapter. 0.0 Release Notes o HP Ethernet 10Gb 2-port 562i Adapter HP Intel Online Firmware Upgrade Utility for Windows Server 2008 Version: 4.10 (D) (Optional) 508 Prerequisites This package requires the appropriate driver for your NIC be installed before firmware can be updated. This component addresses an issue that resulted in sideband communication transmitting from the wrong port.0. Available drivers are: o o HP Intel E1R Driver for Windows Server 2008 HP Intel ixn/ixt Driver for Windows Server 2008 Fixes This component addresses an issue which prevented correct operation on the HP Ethernet 1Gb 1-port 364i Adapter.06.0 . Fixes HP | Service Pack for ProLiant 2014.0.HP Service Pack for ProLiant 2014.06.10 (C) (Optional) Prerequisites This package requires the appropriate driver for your NIC be installed before firmware can be updated. Supported Devices and Features This package supports the following network adapters: o o o o o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Intel Online Firmware Upgrade Utility for Windows Server x64 Editions Version: 4.0. This component addresses an issue that resulted in sideband communication transmitting from the wrong port.06.06.HP Service Pack for ProLiant 2014.0 Release Notes This component addresses an issue which prevented correct operation on the HP Ethernet 1Gb 1-port 364i Adapter.0620 for HP NC542m Dual Port Flex-10 10GbE BL-c Adapter Supported Devices and Features This package supports the following network adapters: o o o HP NC542m Dual Port Flex-10 10GbE BL-c Adapter HP NC543i 1-port 4x QDR IB/Flex-10 10Gb Adapter HP NC543i 2-port 4x QDR IB/10Gb Adapter 509 HP | Service Pack for ProLiant 2014.8.0 .1.3 (Recommended) Fixes Fixed in this version: o On nc542m BL-c MINBW and MAXBW set through CLP not working Enhancements This component now contains firmware version 2. Supported Devices and Features This package supports the following network adapters: o o o o o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter HP Mellanox Online Firmware Upgrade Utility for Linux i386 Version: 1. 06.8.0.HP Service Pack for ProLiant 2014.0620 for HP NC542m Dual Port Flex-10 10GbE BL-c Adapter Supported Devices and Features This package supports the following network adapters: o o o HP NC542m Dual Port Flex-10 10GbE BL-c Adapter HP NC543i 1-port 4x QDR IB/Flex-10 10Gb Adapter HP NC543i 2-port 4x QDR IB/10Gb Adapter 510 HP Mellanox Online Firmware Upgrade Utility for Windows Server 2008 x64 Editions Version: 1.1 (A) (Recommended) HP | Service Pack for ProLiant 2014.0.8.06.3 (Recommended) Fixes Fixed in this version: o On nc542m BL-c MINBW and MAXBW set through CLP not working Enhancements This component now contains firmware version 2.0620 for HP NC542m Dual Port Flex-10 10GbE BL-c Adapter Supported Devices and Features This package supports the following network adapters: o o o HP NC542m Dual Port Flex-10 10GbE BL-c Adapter HP NC543i 1-port 4x QDR IB/Flex-10 10Gb Adapter HP NC543i 2-port 4x QDR IB/10Gb Adapter HP Mellanox Online Firmware Upgrade Utility for Windows Server 2008 Version: 1.0 .0.0.0 Release Notes HP Mellanox Online Firmware Upgrade Utility for Linux x86_64 Version: 1.1.1 (Recommended) Fixes Fixed in this version: o On nc542m BL-c MINBW and MAXBW set through CLP not working Enhancements This component now contains firmware version 2. 6 (Optional) Prerequisites When updating firmware on P3 devices. Driver version 4. Using the P3 firmware in this package without driver version 4.4.0.06.555 must be installed after installing the firmware in this package. This package version can be used to upgrade firmware versioned: o o 3.0.HP Service Pack for ProLiant 2014. this package requires HP QLogic nx_nic Driver for Linux version >= 4. Supported Devices and Features This software supports the following HP QLogic P2 network adapters: o HP NC510F PCIe 10 Gigabit Serve Adapter HP | Service Pack for ProLiant 2014.540 and < 4.230 and later for all other supported network adapters Fixes The P3 firmware in this product corrects the reporting of checksum status for packets with TCP checksum errors while running in promiscuous mode.0 Release Notes Fixes Fixed in this version: o On nc542m BL-c MINBW and MAXBW set through CLP not working Enhancements o o Added supoprt for Windows 2012 R2 This component now contains firmware version 2.0.0.555 or later is not a supported configuration.555 for installation.06.0620 for HP NC542m Dual Port Flex-10 10GbE BL-c Adapter Supported Devices and Features This package supports the following network adapters: o o o HP NC542m Dual Port Flex-10 10GbE BL-c Adapter HP NC543i 1-port 4x QDR IB/Flex-10 10Gb Adapter HP NC543i 2-port 4x QDR IB/10Gb Adapter HP QLogic P2/P3 Online Firmware Upgrade Utility for Linux x86 Version: 5.0.4.8.336 and later for the NC510C and NC510F network adapters 4.0 511 . 336 and later for the NC510C and NC510F network adapters 4.0.0.0. Using the P3 firmware in this package without driver version 4.0 Release Notes o HP NC510C PCIe 10 Gigabit Serve Adapter This software supports the following HP QLogic P3 network adapters: o o o o o HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic P2/P3 Online Firmware Upgrade Utility for Linux x86_64 Version: 5.4.555 must be installed after installing the firmware in this package.06. this package requires HP QLogic nx_nic Driver for Linux version >= 4.0.4. Supported Devices and Features This software supports the following HP QLogic P2 network adapters: o o HP NC510F PCIe 10 Gigabit Serve Adapter HP NC510C PCIe 10 Gigabit Serve Adapter This software supports the following HP QLogic P3 network adapters: o o o o HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP | Service Pack for ProLiant 2014.555 for installation.0.6 (Optional) Prerequisites When updating firmware on P3 devices. Driver version 4.0 512 .555 or later is not a supported configuration.230 and later for all other supported network adapters Fixes The P3 firmware in this product corrects the reporting of checksum status for packets with TCP checksum errors while running in promiscuous mode.HP Service Pack for ProLiant 2014.06. This package version can be used to upgrade firmware versioned: o o 3.540 and < 4. 11 (Optional) Prerequisites This package requires the HP QLogic qlcnic Driver for Linux to be installed before firmware can be updated.0.26. Supported Devices and Features This software supports the following HP QLogic P3 network adapters: o o o o o HP NC522m Dual Port 10GbE Multifunction BL-c Adapter HP NC522SFP Dual Port 10GbE Server Adapter HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter HP NC375i 1G w/NC524SFP 10G Module HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic P3P Online Firmware Upgrade Utility for Linux x86 Version: 1. This firmware is part of a combo image file p3p26002.0.5. Supported Devices and Features This package supports the following network adapters: o o o HP CN1000Q Dual Port Converged Network Adapter HP NC523SFP 10Gb 2-port Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP QLogic P3P Online Firmware Upgrade Utility for Linux x86_64 Version: 1.14.bin (v2.11 (Optional) Prerequisites This package requires the HP QLogic qlcnic Driver for Linux to be installed before firmware can be updated. Enhancements This component provides firmware version 4. HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.60.. This image contains signed Unified Extensible Firmware Interface (UEFI) drivers.0 513 .06.0 Release Notes o HP NC375T PCI Express Quad Port Gigabit Server Adapter HP QLogic P3 Online Firmware Upgrade Utility for Windows Server 2008 Version: 4.5.02).16 (Optional) Fixes This component corrects an issue where the flash engine may cause an application crash during execution in Japanese language OSes.06. Supported Devices and Features This package supports the following network adapters: o o o HP CN1000Q Dual Port Converged Network Adapter HP NC523SFP 10Gb 2-port Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP QLogic P3P Online Firmware Upgrade Utility for VMware 5. This firmware is part of a combo image file p3p26002.15 (C) (Optional) Prerequisites This package requires the HP QLogic P3P Multifunction Driver for Windows Server 2008 to be installed before firmware can be updated.26. Enhancements This component provides firmware version 4.6 (Optional) Prerequisites This package requires the appropriate HP QLogic driver for VMware for your device to be installed before firmware can be updated. This image contains signed Unified Extensible Firmware Interface (UEFI) drivers.0. This firmware is part of a combo image file p3p26002.bin (v2.HP Service Pack for ProLiant 2014. Enhancements This component provides firmware version 4.x Version: 2.0 514 .14.06.1.bin (v2. This firmware is part of a combo image file p3p26002.26.bin (v2.60.02).26.14.60.02). Supported Devices and Features This software package supports the following HP P3P network adapters: o o HP CN1000Q Dual Port Converged Network Adapter HP NC523SFP 10Gb 2-port Server Adapter HP | Service Pack for ProLiant 2014.02).0.14. Supported Devices and Features This package supports the following network adapters: o o o HP StorageWorks CN1000Q Dual Port Converged Network Adapter HP NC523SFP 10Gb 2-port Flex-10 Ethernet Server Adapter HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter HP QLogic P3P Online Firmware Upgrade Utility for Windows Server 2008 Version: 4.06.60.0 Release Notes Enhancements This component provides firmware version 4. 5m FDR cable. On Pilot1 SL230.HP Service Pack for ProLiant 2014.0-3. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. do you want to continue ? (y/n) [n] : y 515 Prerequisites Fixes HP | Service Pack for ProLiant 2014. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. 40GbE link takes longer to establish link when CR4 is used. Workaround: Use other SFP to RJ45 adapters. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI.1 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue. PCIe link occasionally does not come up at Gen3 speed.11. old FW configurations will be cleared. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. Bloom filter is currently not supported. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. a FDR10 link is established instead of FDR. support is not declared for this SFP to RJ45 module. Occasionally.0. Workaround: Production SL230 should be used for PCIe Gen3 operation.0000 and using MFT 3. due to effects on link up/down on the adjacent port.0. VLAN filter is currently not supported. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module.06. When PCIe Gen3 is enabled. RH6. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). PXE is currently not supported in 40GbE in VPI cards. When downgrading from firmware v2. Device managed Flow steering and NCSI cannot be enabled simultaneously. PXE is currently not supported in QSFP to SFP+ hybrid cable. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters.06.0 Release Notes o HP FlexFabric 10Gb 2-port 526FLR-SFP+ Adapter Online Firmware Upgrade Utility (ESXi Server) for HP InfiniBand FDR/EN 10/40Gb Dual Port 544QSFP Adapter: HP Part # 649281-B21 Version: 1. Auto-Sensing is not supported with 40GbE connections in VPI cards. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2. In a back-to-back setup of FDR cards connected with a 0.0 . the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW. If you continue. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash.06. Enhancements Includes firmware version 2. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex.30. PLL calibration were affected by operating point configuration. Under certain conditions. Fixed process voltage scaling issue. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. When the same VLAN is configured for both ports and one port goes down. Upon failure.3200 HP | Service Pack for ProLiant 2014. On rare occasions. the link may raise in a lower speed than expected. Port error counters were not cleared upon XAUI/SGMII link up. the following message is received: “Payload inaccessible . On rare occasions. an NMI event occurred on HP ALOM while trying to using the PXE CLI.06. Occasionally. to support specific 10GbE QSFP to SFP+ splitter cables. SR-IOV guest experienced request timeouts and got stuck. During repeated cable reinsertion. On rare link reset occasions. Management transport was not supported. PXE might halt during teardown. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link.3200 for the below card: 516  Rev B3 (PSID: HP_0280210019] . and not reach the Active state. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. after PXE driver teardown (unload). a failure occurred in speed when changing to Gen2. Fixed miss cqe issue due to interrupt moderation. the second port may suffer a momentarily packet drop. When changing link connection between 40Gbe to 10Gbe. Slow link establishment in NC-SI caused due to slow cable reading in boot.2. Fixed a possible read access to DMA address 0x0. Fixed the flow to issue software reset. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. InfiniBand loopback was blocked during link negotiation on the same port.30. Fixed a rare cable reading issue upon cable insertion.HP Service Pack for ProLiant 2014. the port might stay down until the next driver restart.cannot continue”. IPv6 packets dropped while RoCE was enabled. after the driver was stopped.0 . Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI.0 Release Notes Fixes: o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. On rare occasions. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. Fixed a possible access to unmapped resource memory. Enhanced the receiver SerDes tuning for 10GE. 0000 and using MFT 3. RH6.5m FDR cable. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. Auto-Sensing is not supported with 40GbE connections in VPI cards. support is not declared for this SFP to RJ45 module. PCIe link occasionally does not come up at Gen3 speed. Under certain conditions. Workaround: Production SL230 should be used for PCIe Gen3 operation. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). When downgrading from firmware v2. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. Bloom filter is currently not supported.0 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. In a back-to-back setup of FDR cards connected with a 0.0-3. If you continue. old FW configurations will be cleared. PXE is currently not supported in 40GbE in VPI cards. PXE is currently not supported in QSFP to SFP+ hybrid cable. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module. Device managed Flow steering and NCSI cannot be enabled simultaneously.06.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue. 40GbE link takes longer to establish link when CR4 is used. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock HP | Service Pack for ProLiant 2014. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). do you want to continue ? (y/n) [n] : y Fixes Fixes: o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI.0. When PCIe Gen3 is enabled.0. On Pilot1 SL230.0 Release Notes Online Firmware Upgrade Utility (ESXi Server) for HP InfiniBand FDR/EN 10/40Gb Dual Port 544QSFP Adapter: HP Part # 649281-B21 Version: 1.HP Service Pack for ProLiant 2014. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2. Workaround: Use other SFP to RJ45 adapters. due to effects on link up/down on the adjacent port. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW.11. VLAN filter is currently not supported. SR-IOV guest experienced request timeouts and got stuck.06.0 517 . Occasionally. a FDR10 link is established instead of FDR. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. after the driver was stopped.30. the link may raise in a lower speed than expected. When the same VLAN is configured for both ports and one port goes down. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. IPv6 packets dropped while RoCE was enabled. Port error counters were not cleared upon XAUI/SGMII link up. Fixed a rare cable reading issue upon cable insertion. Fixed a possible read access to DMA address 0x0. a failure occurred in speed when changing to Gen2. the port might stay down until the next driver restart. after PXE driver teardown (unload). On rare occasions.2. Fixed the flow to issue software reset. an NMI event occurred on HP ALOM while trying to using the PXE CLI. Enhanced the receiver SerDes tuning for 10GE. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. On rare occasions. Upon failure. On rare occasions.30.0 . InfiniBand loopback was blocked during link negotiation on the same port.06. and not reach the Active state.HP Service Pack for ProLiant 2014. Slow link establishment in NC-SI caused due to slow cable reading in boot.cannot continue”. Fixed a possible access to unmapped resource memory. the second port may suffer a momentarily packet drop. Occasionally. On rare link reset occasions. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. Enhancements Includes firmware version 2.3200 for the below card:  Rev B3 (PSID: HP_0280210019] . the following message is received: “Payload inaccessible . PXE might halt during teardown.0 Release Notes o o o o o o o o o o o o o o o o o o o o o o o o o and fail ETH KR link. to support specific 10GbE QSFP to SFP+ splitter cables. When changing link connection between 40Gbe to 10Gbe. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. PLL calibration were affected by operating point configuration. Management transport was not supported. an NMI error is received when stopping PXE boot in the middle of an action on HP servers.06.3200 518 HP | Service Pack for ProLiant 2014. Fixed process voltage scaling issue. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. During repeated cable reinsertion. Fixed miss cqe issue due to interrupt moderation. 40GbE link takes longer to establish link when CR4 is used. old FW configurations will be cleared.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue.0000 and using MFT 3.11. HP | Service Pack for ProLiant 2014. When downgrading from firmware v2. due to effects on link up/down on the adjacent port.0 . Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only).5m FDR cable.0 Release Notes Online Firmware Upgrade Utility (Linux x86_64) for HP InfiniBand FDR/EN 10/40Gb Dual Port 544FLR-QSFP Adapter: HP Part # 649282-B21 and HP InfiniBand QDR/EN 10Gb Dual Port 544FLR-QSFP Adapter: HP Part # 649283B21 Version: 1. do you want to continue ? (y/n) [n] : y Fixes 519 Fixes: o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch.06. Workaround: Use other SFP to RJ45 adapters. Occasionally. When PCIe Gen3 is enabled. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. PXE is currently not supported in QSFP to SFP+ hybrid cable. If you continue. Bloom filter is currently not supported. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. In a back-to-back setup of FDR cards connected with a 0.7 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. RH6.06.0. Workaround: Production SL230 should be used for PCIe Gen3 operation. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. On Pilot1 SL230. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. PCIe link occasionally does not come up at Gen3 speed. PXE is currently not supported in 40GbE in VPI cards. Device managed Flow steering and NCSI cannot be enabled simultaneously. support is not declared for this SFP to RJ45 module. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW.HP Service Pack for ProLiant 2014. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2.0-3. Auto-Sensing is not supported with 40GbE connections in VPI cards. VLAN filter is currently not supported. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters. a FDR10 link is established instead of FDR. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration.1. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. the link may raise in a lower speed than expected. Fixed a possible read access to DMA address 0x0. On rare occasions.30. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. Fixed the flow to issue software reset. to support specific 10GbE QSFP to SFP+ splitter cables. after the driver was stopped. Upon failure. after PXE driver teardown (unload). When the same VLAN is configured for both ports and one port goes down. PLL calibration were affected by operating point configuration. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. Fixed a rare cable reading issue upon cable insertion.06. Fixed a possible access to unmapped resource memory.cannot continue”. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. Occasionally.3200 for the below adapter types:     Rev B2 (PSID: HP_0230220019) Rev Cx (PSID: HP_0230240019) Rev B2 (PSID: HP_0230220009) Rev Cx (PSID: HP_0230240009) 520 HP | Service Pack for ProLiant 2014. an NMI event occurred on HP ALOM while trying to using the PXE CLI. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. IPv6 packets dropped while RoCE was enabled. During repeated cable reinsertion. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. Management transport was not supported. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. Port error counters were not cleared upon XAUI/SGMII link up. InfiniBand loopback was blocked during link negotiation on the same port.06. SR-IOV guest experienced request timeouts and got stuck. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred.0 . On rare occasions. o o o o o o o o o o o o o o o o o o o o o o o o o Enhancements Includes firmware version 2. On rare occasions. a failure occurred in speed when changing to Gen2. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. Enhanced the receiver SerDes tuning for 10GE. On rare link reset occasions. and not reach the Active state. Fixed miss cqe issue due to interrupt moderation. Slow link establishment in NC-SI caused due to slow cable reading in boot. Fixed process voltage scaling issue. the following message is received: “Payload inaccessible . PXE might halt during teardown.0 Release Notes o o Under certain conditions.HP Service Pack for ProLiant 2014. the second port may suffer a momentarily packet drop. When changing link connection between 40Gbe to 10Gbe. the port might stay down until the next driver restart. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module.0 521 . support is not declared for this SFP to RJ45 module.3 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped.1.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue. 40GbE link takes longer to establish link when CR4 is used. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. When downgrading from firmware v2. old FW configurations will be cleared.0. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). do you want to continue ? (y/n)[n] : y You are trying to restore default configuration.0-3. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang.HP Service Pack for ProLiant 2014. Device managed Flow steering and NCSI cannot be enabled simultaneously. HP | Service Pack for ProLiant 2014. a FDR10 link is established instead of FDR. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. Auto-Sensing is not supported with 40GbE connections in VPI cards. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. On Pilot1 SL230. Under certain conditions. Workaround: Production SL230 should be used for PCIe Gen3 operation. SR-IOV guest experienced request timeouts and got stuck. PXE is currently not supported in QSFP to SFP+ hybrid cable. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module. Workaround: Use other SFP to RJ45 adapters. In a back-to-back setup of FDR cards connected with a 0. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link.5m FDR cable. VLAN filter is currently not supported. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI.06.0 Release Notes Online Firmware Upgrade Utility (Linux x86_64) for HP InfiniBand FDR/EN 10/40Gb Dual Port 544QSFP Adapter: HP Part # 649281-B21 Version: 1. Bloom filter is currently not supported. RH6.06. PCIe link occasionally does not come up at Gen3 speed. If you continue.0000 and using MFT 3. do you want to continue ? (y/n) [n] : y Fixes Fixes: o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. When PCIe Gen3 is enabled. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters. Occasionally. PXE is currently not supported in 40GbE in VPI cards. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2. due to effects on link up/down on the adjacent port. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036).11. Enhancements Includes firmware version 2.0 Release Notes o o o o o o o o o o o o o o o o o o o o o o o o o Management transport was not supported. When changing link connection between 40Gbe to 10Gbe. When the same VLAN is configured for both ports and one port goes down. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. after PXE driver teardown (unload). PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. On rare occasions. the second port may suffer a momentarily packet drop. Upon failure. Occasionally. Fixed a possible access to unmapped resource memory.3200 for the below card:  Rev B3 (PSID: HP_0280210019] . IPv6 packets dropped while RoCE was enabled.2 (Recommended) HP | Service Pack for ProLiant 2014. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. Enhanced the receiver SerDes tuning for 10GE.0 522 . the link may raise in a lower speed than expected. Fixed miss cqe issue due to interrupt moderation. On rare occasions. and not reach the Active state. Fixed a rare cable reading issue upon cable insertion.06. Port error counters were not cleared upon XAUI/SGMII link up. to support specific 10GbE QSFP to SFP+ splitter cables. Fixed process voltage scaling issue.30.HP Service Pack for ProLiant 2014.3200 Online Firmware Upgrade Utility (Linux x86_64) for HP InfiniBand QDR/EN 10Gb Dual Port 544M Adapter: HP Part # 644160-B21 and HP InfiniBand FDR/EN 10/40Gb Dual Port 544M Adapter: HP Part # 644161-B21 Version: 1. Slow link establishment in NC-SI caused due to slow cable reading in boot. the following message is received: “Payload inaccessible .2. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred.1.30. a failure occurred in speed when changing to Gen2. On rare occasions. InfiniBand loopback was blocked during link negotiation on the same port. Fixed the flow to issue software reset. During repeated cable reinsertion.06. an NMI event occurred on HP ALOM while trying to using the PXE CLI. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. Fixed a possible read access to DMA address 0x0. after the driver was stopped. the port might stay down until the next driver restart. PXE might halt during teardown.cannot continue”. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. On rare link reset occasions. PLL calibration were affected by operating point configuration. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module. Under certain conditions. When downgrading from firmware v2.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue. When PCIe Gen3 is enabled. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. Auto-Sensing is not supported with 40GbE connections in VPI cards.0. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead HP | Service Pack for ProLiant 2014.0000 and using MFT 3. Fixed the flow to issue software reset. PCIe link occasionally does not come up at Gen3 speed. due to effects on link up/down on the adjacent port. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW.06. a FDR10 link is established instead of FDR. after the driver was stopped. after PXE driver teardown (unload). do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. old FW configurations will be cleared.11. support is not declared for this SFP to RJ45 module.0-3. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). Device managed Flow steering and NCSI cannot be enabled simultaneously. do you want to continue ? (y/n) [n] : y Fixes Fixes: o o o o o o o Fixed FDR firmware payload issue within the smart component. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). Bloom filter is currently not supported. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters. 40GbE link takes longer to establish link when CR4 is used. In a back-to-back setup of FDR cards connected with a 0. RH6.0 523 . SR-IOV guest experienced request timeouts and got stuck.HP Service Pack for ProLiant 2014.0 Release Notes Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. If you continue. PXE is currently not supported in QSFP to SFP+ hybrid cable.06. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2.5m FDR cable. Workaround: Use other SFP to RJ45 adapters. Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. Workaround: Production SL230 should be used for PCIe Gen3 operation. On Pilot1 SL230. VLAN filter is currently not supported. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. Management transport was not supported. Occasionally. PXE is currently not supported in 40GbE in VPI cards. Upon failure.0 524 .2. Enhancements Includes firmware version 2. and not reach the Active state. PLL calibration were affected by operating point configuration. Fixed a possible access to unmapped resource memory.3200 for the below card:  Rev B3 (PSID: HP_0240230019] . the following message is received: “Payload inaccessible . On rare occasions. Fixed a rare cable reading issue upon cable insertion.30. On rare link reset occasions. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. Fixed a possible read access to DMA address 0x0. Fixed miss cqe issue due to interrupt moderation.cannot continue”. Enhanced the receiver SerDes tuning for 10GE. During repeated cable reinsertion. When the same VLAN is configured for both ports and one port goes down. PXE might halt during teardown. When changing link connection between 40Gbe to 10Gbe. to support specific 10GbE QSFP to SFP+ splitter cables. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. On rare occasions. a failure occurred in speed when changing to Gen2. IPv6 packets dropped while RoCE was enabled.HP Service Pack for ProLiant 2014.06.30.06. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. Port error counters were not cleared upon XAUI/SGMII link up. On rare occasions. InfiniBand loopback was blocked during link negotiation on the same port. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. Fixed process voltage scaling issue. the link may raise in a lower speed than expected.0 Release Notes o o o o o o o o o o o o o o o o o o o o o o o of 0.1.30. Slow link establishment in NC-SI caused due to slow cable reading in boot. the second port may suffer a momentarily packet drop.2. the port might stay down until the next driver restart. Occasionally.3200 Online Firmware Upgrade Utility (Linux x86_64) for HP Infiniband QDR/Ethernet 10Gb 2P 544i Adapter (SL4540 and SL4545 only) Version: 1. an NMI event occurred on HP ALOM while trying to using the PXE CLI.3200  Rev B3 (PSID: HP_0250230018] . The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. an NMI error is received when stopping PXE boot in the middle of an action on HP servers.1 (Recommended) Important Note! Known Issues: HP | Service Pack for ProLiant 2014. Bloom filter is currently not supported. to support specific 10GbE QSFP to SFP+ splitter HP | Service Pack for ProLiant 2014. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). old FW configurations will be cleared. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters.HP Service Pack for ProLiant 2014. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. Management transport was not supported.0. PXE is currently not supported in 40GbE in VPI cards. Under certain conditions. Workaround: Production SL230 should be used for PCIe Gen3 operation. Enhanced the receiver SerDes tuning for 10GE. PLL calibration were affected by operating point configuration.0-3. PXE is currently not supported in QSFP to SFP+ hybrid cable. support is not declared for this SFP to RJ45 module. Workaround: Use other SFP to RJ45 adapters. In a back-to-back setup of FDR cards connected with a 0.0 525 . PCIe link occasionally does not come up at Gen3 speed. Port error counters were not cleared upon XAUI/SGMII link up. Device managed Flow steering and NCSI cannot be enabled simultaneously. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module.06. RH6. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW. If you continue. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. Fixed the flow to issue software reset. On Pilot1 SL230. VLAN filter is currently not supported. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. after PXE driver teardown (unload). due to effects on link up/down on the adjacent port. 40GbE link takes longer to establish link when CR4 is used. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. a FDR10 link is established instead of FDR. When PCIe Gen3 is enabled. after the driver was stopped. do you want to continue ? (y/n) [n] : y Fixes Fixes: o o o o o o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. Occasionally. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. When downgrading from firmware v2.5m FDR cable. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2.0 Release Notes o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped.0000 and using MFT 3. Auto-Sensing is not supported with 40GbE connections in VPI cards.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue.11. SR-IOV guest experienced request timeouts and got stuck. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module.06. 30. Fixed a possible access to unmapped resource memory. Fixed a rare cable reading issue upon cable insertion.2. On rare link reset occasions.30. When the same VLAN is configured for both ports and one port goes down. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash.06. a failure occurred in speed when changing to Gen2. Enhancements Includes firmware version 2. the port might stay down until the next driver restart. On rare occasions. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. the link may raise in a lower speed than expected. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. an NMI event occurred on HP ALOM while trying to using the PXE CLI. the following message is received: “Payload inaccessible .3200 for the below card:  Rev B3 (PSID: HP_0280110018] . The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex.3200 Supported Devices and Features This package supports the following InfiniBand adapters: o HP Infiniband QDR/Ethernet 10Gb 2P 544i Adapter (SL4540 and SL4545 only) 526 HP | Service Pack for ProLiant 2014. Fixed a possible read access to DMA address 0x0.0 . Occasionally. On rare occasions. During repeated cable reinsertion. When changing link connection between 40Gbe to 10Gbe. On rare occasions. IPv6 packets dropped while RoCE was enabled. Fixed process voltage scaling issue. InfiniBand loopback was blocked during link negotiation on the same port.cannot continue”. the second port may suffer a momentarily packet drop. PXE might halt during teardown.0 Release Notes o o o o o o o o o o o o o o o o o o o o cables. and not reach the Active state. Slow link establishment in NC-SI caused due to slow cable reading in boot.06. Fixed miss cqe issue due to interrupt moderation. Upon failure. an HCA to SwitchX link may remain in ARM state after SwitchX reboot.HP Service Pack for ProLiant 2014. RH6. Auto-Sensing is not supported with 40GbE connections in VPI cards.HP Service Pack for ProLiant 2014. do you want to continue ? (y/n) [n] : y Prerequisites 527 Fixes HP | Service Pack for ProLiant 2014. Occasionally. On Pilot1 SL230. PCIe link occasionally does not come up at Gen3 speed.0-3. PXE is currently not supported in QSFP to SFP+ hybrid cable. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters.1 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). Workaround: Use other SFP to RJ45 adapters. In a back-to-back setup of FDR cards connected with a 0.06. old FW configurations will be cleared. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV.0. VLAN filter is currently not supported. PXE is currently not supported in 40GbE in VPI cards. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration.0 . If you continue. Device managed Flow steering and NCSI cannot be enabled simultaneously. When PCIe Gen3 is enabled. due to effects on link up/down on the adjacent port. Bloom filter is currently not supported. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2.5m FDR cable.11. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. a FDR10 link is established instead of FDR. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang.06.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue.0 Release Notes Online Firmware Upgrade Utility (VMware ESXi Server) for HP InfiniBand FDR/EN 10/40Gb Dual Port 544FLR-QSFP Adapter: HP Part # 649282-B21 and HP InfiniBand QDR/EN 10Gb Dual Port 544FLR-QSFP Adapter: HP Part # 649283-B21 Version: 1. Workaround: Production SL230 should be used for PCIe Gen3 operation. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). When downgrading from firmware v2. support is not declared for this SFP to RJ45 module.0000 and using MFT 3.0. 40GbE link takes longer to establish link when CR4 is used. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. 30. On rare occasions. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. after PXE driver teardown (unload). Fixed a possible read access to DMA address 0x0. the port might stay down until the next driver restart. Upon failure. an NMI event occurred on HP ALOM while trying to using the PXE CLI.0 Release Notes Fixes: o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. PLL calibration were affected by operating point configuration. the following message is received: “Payload inaccessible . InfiniBand loopback was blocked during link negotiation on the same port. Fixed the flow to issue software reset. Fixed a rare cable reading issue upon cable insertion. On rare occasions. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. and not reach the Active state. Enhancements Includes firmware version 2.0 528 .HP Service Pack for ProLiant 2014. On rare link reset occasions. Enhanced the receiver SerDes tuning for 10GE. Management transport was not supported. When the same VLAN is configured for both ports and one port goes down. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. to support specific 10GbE QSFP to SFP+ splitter cables. PXE might halt during teardown. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. IPv6 packets dropped while RoCE was enabled. after the driver was stopped. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. Fixed a possible access to unmapped resource memory. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. During repeated cable reinsertion.cannot continue”. the link may raise in a lower speed than expected. Slow link establishment in NC-SI caused due to slow cable reading in boot. Occasionally.06. Fixed miss cqe issue due to interrupt moderation. a failure occurred in speed when changing to Gen2. On rare occasions. Under certain conditions.3200 for the below adapter types:  Rev B2 (PSID: HP_0230220019)  Rev Cx (PSID: HP_0230240019)  Rev B2 (PSID: HP_0230220009) HP | Service Pack for ProLiant 2014. Fixed process voltage scaling issue. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. When changing link connection between 40Gbe to 10Gbe. SR-IOV guest experienced request timeouts and got stuck.06. the second port may suffer a momentarily packet drop. Port error counters were not cleared upon XAUI/SGMII link up. 5m FDR cable. If you continue.0 Release Notes  Rev Cx (PSID: HP_0230240009) Online Firmware Upgrade Utility (VMware ESXi Server) for HP InfiniBand FDR/EN 10/40Gb Dual Port 544FLR-QSFP Adapter: HP Part # 649282-B21 and HP InfiniBand QDR/EN 10Gb Dual Port 544FLR-QSFP Adapter: HP Part # 649283-B21 Version: 1. due to effects on link up/down on the adjacent port. Occasionally.0000 and using MFT 3. Workaround: Use other SFP to RJ45 adapters. support is not declared for this SFP to RJ45 module. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). a FDR10 link is established instead of FDR. On Pilot1 SL230. When downgrading from firmware v2. Device managed Flow steering and NCSI cannot be enabled simultaneously.HP Service Pack for ProLiant 2014. PXE is currently not supported in 40GbE in VPI cards.06. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters. 40GbE link takes longer to establish link when CR4 is used.0. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW.0-3. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. In a back-to-back setup of FDR cards connected with a 0.11. VLAN filter is currently not supported.0. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2. Workaround: Production SL230 should be used for PCIe Gen3 operation. do you want to continue ? (y/n) [n] : y Prerequisites HP | Service Pack for ProLiant 2014. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. PCIe link occasionally does not come up at Gen3 speed. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). Auto-Sensing is not supported with 40GbE connections in VPI cards.0 529 . When PCIe Gen3 is enabled. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module.0 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. PXE is currently not supported in QSFP to SFP+ hybrid cable. old FW configurations will be cleared.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue. Bloom filter is currently not supported.06. RH6. 06. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. SR-IOV guest experienced request timeouts and got stuck. an HCA to SwitchX link may remain in ARM state after SwitchX reboot.30. PXE might halt during teardown. Fixed miss cqe issue due to interrupt moderation. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI.06. Fixed a rare cable reading issue upon cable insertion. When the same VLAN is configured for both ports and one port goes down. Enhanced the receiver SerDes tuning for 10GE. Slow link establishment in NC-SI caused due to slow cable reading in boot. Fixed the flow to issue software reset. On rare occasions. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. Occasionally. the second port may suffer a momentarily packet drop.HP Service Pack for ProLiant 2014.cannot continue”. On rare occasions. a failure occurred in speed when changing to Gen2.0 . During repeated cable reinsertion. On rare link reset occasions. to support specific 10GbE QSFP to SFP+ splitter cables. Under certain conditions. Management transport was not supported. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. On rare occasions. PLL calibration were affected by operating point configuration. InfiniBand loopback was blocked during link negotiation on the same port. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. Port error counters were not cleared upon XAUI/SGMII link up.3200 for the below adapter types: HP | Service Pack for ProLiant 2014. 530 Enhancements Includes firmware version 2. and not reach the Active state. When changing link connection between 40Gbe to 10Gbe. the following message is received: “Payload inaccessible . IPv6 packets dropped while RoCE was enabled. Fixed a possible access to unmapped resource memory. Fixed a possible read access to DMA address 0x0. Upon failure. Fixed process voltage scaling issue. an NMI event occurred on HP ALOM while trying to using the PXE CLI. after the driver was stopped. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. the link may raise in a lower speed than expected. the port might stay down until the next driver restart.0 Release Notes Fixes Fixes: o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. after PXE driver teardown (unload). PCIe link occasionally does not come up at Gen3 speed. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters. Auto-Sensing is not supported with 40GbE connections in VPI cards.HP Service Pack for ProLiant 2014.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue.5m FDR cable. Occasionally. due to effects on link up/down on the adjacent port. do you want to continue ? (y/n) [n] : y HP | Service Pack for ProLiant 2014. Workaround: Production SL230 should be used for PCIe Gen3 operation. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. 40GbE link takes longer to establish link when CR4 is used. When downgrading from firmware v2. PXE is currently not supported in 40GbE in VPI cards. support is not declared for this SFP to RJ45 module. PXE is currently not supported in QSFP to SFP+ hybrid cable. old FW configurations will be cleared. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). Device managed Flow steering and NCSI cannot be enabled simultaneously. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2.0.11. Bloom filter is currently not supported.0 Release Notes     Rev B2 (PSID: HP_0230220019) Rev Cx (PSID: HP_0230240019) Rev B2 (PSID: HP_0230220009) Rev Cx (PSID: HP_0230240009) Online Firmware Upgrade Utility (VMware ESXi Server) for HP InfiniBand QDR/EN 10Gb Dual Port 544M Adapter: HP Part # 644160-B21 and HP InfiniBand FDR/EN 10/40Gb Dual Port 544M Adapter: HP Part # 644161-B21 Version: 1. Workaround: Use other SFP to RJ45 adapters. When PCIe Gen3 is enabled. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module.0.06.1 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. On Pilot1 SL230. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module. VLAN filter is currently not supported. a FDR10 link is established instead of FDR.0 531 . PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. In a back-to-back setup of FDR cards connected with a 0.0000 and using MFT 3. If you continue. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only).0-3.06. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW. RH6. 0 532 . IPv6 packets dropped while RoCE was enabled. Fixed the flow to issue software reset. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. a failure occurred in speed when changing to Gen2. Fixed a rare cable reading issue upon cable insertion. the second port may suffer a momentarily packet drop. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. Management transport was not supported. the link may raise in a lower speed than expected.0 Release Notes Prerequisites Fixes Fixes: o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. the following message is received: “Payload inaccessible . During repeated cable reinsertion. an NMI event occurred on HP ALOM while trying to using the PXE CLI. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. Fixed a possible read access to DMA address 0x0. When the same VLAN is configured for both ports and one port goes down. and not reach the Active state. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex.cannot continue”. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. to support specific 10GbE QSFP to SFP+ splitter cables. the port might stay down until the next driver restart. Under certain conditions. On rare occasions. Fixed process voltage scaling issue. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. When changing link connection between 40Gbe to 10Gbe. Fixed a possible access to unmapped resource memory. Upon failure. PXE might halt during teardown. Port error counters were not cleared upon XAUI/SGMII link up. Slow link establishment in NC-SI caused due to slow cable reading in boot. after the driver was stopped. Fixed miss cqe issue due to interrupt moderation. Occasionally. SR-IOV guest experienced request timeouts and got stuck. InfiniBand loopback was blocked during link negotiation on the same port. On rare link reset occasions. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. On rare occasions.HP Service Pack for ProLiant 2014. HP | Service Pack for ProLiant 2014. PLL calibration were affected by operating point configuration.06. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. On rare occasions.06. after PXE driver teardown (unload). Enhanced the receiver SerDes tuning for 10GE. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). When downgrading from firmware v2. a FDR10 link is established instead of FDR. RH6. When PCIe Gen3 is enabled. If you continue. Occasionally.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue. support is not declared for this SFP to RJ45 module. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only).0-3.3200 for the below card:  Rev B3 (PSID: HP_0240230019] . The locked semaphore prevents the firmware from accessing the flash and causes firmware hang.0. Workaround: Use other SFP to RJ45 adapters.0 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port.3200  Rev B3 (PSID: HP_0250230018] . 40GbE link takes longer to establish link when CR4 is used.06.30. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. PXE is currently not supported in QSFP to SFP+ hybrid cable. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters.3200 Online Firmware Upgrade Utility (VMware ESXi Server) for HP InfiniBand QDR/EN 10Gb Dual Port 544M Adapter: HP Part # 644160-B21 and HP InfiniBand FDR/EN 10/40Gb Dual Port 544M Adapter: HP Part # 644161-B21 Version: 1. Device managed Flow steering and NCSI cannot be enabled simultaneously. PCIe link occasionally does not come up at Gen3 speed.2. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW. Auto-Sensing is not supported with 40GbE connections in VPI cards. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI.0000 and using MFT 3. Workaround: Production SL230 should be used for PCIe Gen3 operation.0. PXE is currently not supported in 40GbE in VPI cards.0 Release Notes Enhancements Includes firmware version 2. VLAN filter is currently not supported. On Pilot1 SL230. In a back-to-back setup of FDR cards connected with a 0.30. Bloom filter is currently not supported.0 533 .06. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module.30. do you want to continue ? (y/n) [n] : y HP | Service Pack for ProLiant 2014.5m FDR cable.2. due to effects on link up/down on the adjacent port. old FW configurations will be cleared. Workaround: Clear the semaphore using MFT command: 'flint -clear_semaphore' Although Link and Ping are established using this SFP to RJ45 module.HP Service Pack for ProLiant 2014. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2.11. InfiniBand loopback was blocked during link negotiation on the same port. Fixed miss cqe issue due to interrupt moderation. Port error counters were not cleared upon XAUI/SGMII link up. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash.cannot continue”. Fixed process voltage scaling issue. Management transport was not supported. Occasionally. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. the port might stay down until the next driver restart. On rare link reset occasions.HP Service Pack for ProLiant 2014. Slow link establishment in NC-SI caused due to slow cable reading in boot. Under certain conditions.06. after PXE driver teardown (unload). Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. Fixed the flow to issue software reset. Fixed a possible access to unmapped resource memory. PLL calibration were affected by operating point configuration. When the same VLAN is configured for both ports and one port goes down. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. During repeated cable reinsertion. to support specific 10GbE QSFP to SFP+ splitter cables. SR-IOV guest experienced request timeouts and got stuck. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. PXE might halt during teardown. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. HP | Service Pack for ProLiant 2014. the following message is received: “Payload inaccessible . the link may raise in a lower speed than expected. Enhanced the receiver SerDes tuning for 10GE. and not reach the Active state. a failure occurred in speed when changing to Gen2. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. On rare occasions. When changing link connection between 40Gbe to 10Gbe.06.0 Release Notes Prerequisites Fixes Fixes: o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. after the driver was stopped. Upon failure. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. On rare occasions.0 534 . The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. the second port may suffer a momentarily packet drop. IPv6 packets dropped while RoCE was enabled. an NMI event occurred on HP ALOM while trying to using the PXE CLI. On rare occasions. Fixed a possible read access to DMA address 0x0. Fixed a rare cable reading issue upon cable insertion. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. do you want to continue ? (y/n)[n] : y HP | Service Pack for ProLiant 2014. When downgrading from firmware v2. a FDR10 link is established instead of FDR. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. PXE is currently not supported in QSFP to SFP+ hybrid cable.5m FDR cable. When PCIe Gen3 is enabled. PCIe link occasionally does not come up at Gen3 speed. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2.HP Service Pack for ProLiant 2014.30. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). Auto-Sensing is not supported with 40GbE connections in VPI cards.0000 and using MFT 3.0. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. Workaround: Use other SFP to RJ45 adapters.30.11.30.2.0. support is not declared for this SFP to RJ45 module.0-3. 40GbE link takes longer to establish link when CR4 is used. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW.3200 Online Firmware Upgrade Utility (Windows x64) for HP InfiniBand FDR/EN 10/40Gb Dual Port 544FLR-QSFP Adapter: HP Part # 649282-B21 and HP InfiniBand QDR/EN 10Gb Dual Port 544FLR-QSFP Adapter: HP Part # 649283B21 Version: 1.06. Device managed Flow steering and NCSI cannot be enabled simultaneously. old FW configurations will be cleared. If you continue.1. Occasionally. On Pilot1 SL230. PXE is currently not supported in 40GbE in VPI cards. In a back-to-back setup of FDR cards connected with a 0. Bloom filter is currently not supported. RH6.3200  Rev B3 (PSID: HP_0250230018] .3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue. due to effects on link up/down on the adjacent port. Workaround: Production SL230 should be used for PCIe Gen3 operation. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port.0 535 . VLAN filter is currently not supported.0 Release Notes Enhancements Includes firmware version 2. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only).06.1 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. Workaround: Clear the semaphore using MFT command: flint -clear_semaphore Although Link and Ping are established using this SFP to RJ45 module.3200 for the below card:  Rev B3 (PSID: HP_0240230019] . SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters.2. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. Slow link establishment in NC-SI caused due to slow cable reading in boot. SR-IOV guest experienced request timeouts and got stuck. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. On rare occasions. On rare occasions.0 Release Notes You are trying to restore default configuration. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. after PXE driver teardown (unload). the port might stay down until the next driver restart.06. the following message is received: “Payload inaccessible . do you want to continue ? (y/n) [n] : y Fixes Fixes: o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. an NMI event occurred on HP ALOM while trying to using the PXE CLI. the link may raise in a lower speed than expected. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. Enhancements Includes firmware version 2.3200 for the below adapter types: HP | Service Pack for ProLiant 2014.30. Fixed a rare cable reading issue upon cable insertion. During repeated cable reinsertion. to support specific 10GbE QSFP to SFP+ splitter cables. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. When changing link connection between 40Gbe to 10Gbe. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link.HP Service Pack for ProLiant 2014. Management transport was not supported. IPv6 packets dropped while RoCE was enabled. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. PXE might halt during teardown. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. the second port may suffer a momentarily packet drop. a failure occurred in speed when changing to Gen2. On rare link reset occasions. Fixed the flow to issue software reset. InfiniBand loopback was blocked during link negotiation on the same port. Occasionally. When the same VLAN is configured for both ports and one port goes down. On rare occasions. after the driver was stopped. Enhanced the receiver SerDes tuning for 10GE. Fixed a possible read access to DMA address 0x0. Fixed a possible access to unmapped resource memory.06. and not reach the Active state.cannot continue”. Fixed miss cqe issue due to interrupt moderation. Under certain conditions.0 536 . Upon failure. Fixed process voltage scaling issue. PLL calibration were affected by operating point configuration. Port error counters were not cleared upon XAUI/SGMII link up. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. 0000 and using MFT 3. Workaround: Use other SFP to RJ45 adapters.0 537 . If you continue. old FW configurations will be cleared. support is not declared for this SFP to RJ45 module.9 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped.0 Release Notes     Rev B2 (PSID: HP_0230220019) Rev Cx (PSID: HP_0230240019) Rev B2 (PSID: HP_0230220009) Rev Cx (PSID: HP_0230240009) Online Firmware Upgrade Utility (Windows x64) for HP InfiniBand FDR/EN 10/40Gb Dual Port 544QSFP Adapter: HP Part # 649281-B21 Version: 1. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. Workaround: Production SL230 should be used for PCIe Gen3 operation. PCIe link occasionally does not come up at Gen3 speed. 40GbE link takes longer to establish link when CR4 is used. On Pilot1 SL230.HP Service Pack for ProLiant 2014. RH6. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). In a back-to-back setup of FDR cards connected with a 0. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port. do you want to continue ? (y/n) [n] : y HP | Service Pack for ProLiant 2014. VLAN filter is currently not supported. Workaround: Clear the semaphore using MFT command: flint -clear_semaphore Although Link and Ping are established using this SFP to RJ45 module. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. PXE is currently not supported in QSFP to SFP+ hybrid cable. a FDR10 link is established instead of FDR.0.11. When PCIe Gen3 is enabled.06. Bloom filter is currently not supported.0-3. PXE is currently not supported in 40GbE in VPI cards. When downgrading from firmware v2.5m FDR cable. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. Auto-Sensing is not supported with 40GbE connections in VPI cards. due to effects on link up/down on the adjacent port. Occasionally. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue.0.06. Device managed Flow steering and NCSI cannot be enabled simultaneously. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only).0. Enhancements Includes firmware version 2. Fixed a rare cable reading issue upon cable insertion. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. SR-IOV guest experienced request timeouts and got stuck. Occasionally. Enhanced the receiver SerDes tuning for 10GE. PXE might halt during teardown. When changing link connection between 40Gbe to 10Gbe. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. the second port may suffer a momentarily packet drop. the following message is received: “Payload inaccessible . after PXE driver teardown (unload).06. Management transport was not supported. Fixed process voltage scaling issue. Fixed a possible access to unmapped resource memory. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. Upon failure.30. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. On rare occasions.cannot continue”. Slow link establishment in NC-SI caused due to slow cable reading in boot.2. On rare occasions.30. to support specific 10GbE QSFP to SFP+ splitter cables. and not reach the Active state.3200 HP | Service Pack for ProLiant 2014. InfiniBand loopback was blocked during link negotiation on the same port. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port.0 . Fixed miss cqe issue due to interrupt moderation. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. Port error counters were not cleared upon XAUI/SGMII link up. the port might stay down until the next driver restart. Fixed a possible read access to DMA address 0x0. an NMI event occurred on HP ALOM while trying to using the PXE CLI.3200 for the below card: 538  Rev B3 (PSID: HP_0280210019] . Under certain conditions. Fixed the flow to issue software reset. On rare occasions. a failure occurred in speed when changing to Gen2. During repeated cable reinsertion. PLL calibration were affected by operating point configuration. after the driver was stopped.0 Release Notes Fixes Fixes: o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. the link may raise in a lower speed than expected. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. When the same VLAN is configured for both ports and one port goes down. IPv6 packets dropped while RoCE was enabled. On rare link reset occasions.06. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash.HP Service Pack for ProLiant 2014. When PCIe Gen3 is enabled. PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. HP | Service Pack for ProLiant 2014.0 Release Notes Online Firmware Upgrade Utility (Windows x64) for HP InfiniBand QDR/EN 10Gb Dual Port 544M Adapter: HP Part # 644160-B21 and HP InfiniBand FDR/EN 10/40Gb Dual Port 544M Adapter: HP Part # 644161-B21 Version: 1. On Pilot1 SL230. Workaround: Clear the semaphore using MFT command: flint -clear_semaphore Although Link and Ping are established using this SFP to RJ45 module.06.0-3.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. Device managed Flow steering and NCSI cannot be enabled simultaneously. VLAN filter is currently not supported.HP Service Pack for ProLiant 2014.0. do you want to continue ? (y/n) [n] : y Fixes 539 Fixes: o o Fixed FDR firmware payload issue within the smart component. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). Auto-Sensing is not supported with 40GbE connections in VPI cards.0. Workaround: Use other SFP to RJ45 adapters. Occasionally. PCIe link occasionally does not come up at Gen3 speed. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2. due to effects on link up/down on the adjacent port. old FW configurations will be cleared. PXE is currently not supported in 40GbE in VPI cards. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port.1. If you continue. Workaround: Production SL230 should be used for PCIe Gen3 operation.11. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). Bloom filter is currently not supported. 40GbE link takes longer to establish link when CR4 is used. Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. a FDR10 link is established instead of FDR. In a back-to-back setup of FDR cards connected with a 0.06. When downgrading from firmware v2. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters.5m FDR cable. support is not declared for this SFP to RJ45 module. RH6. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW.0 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. PXE is currently not supported in QSFP to SFP+ hybrid cable.0 .0000 and using MFT 3. 30. the link may raise in a lower speed than expected. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port.0 . During repeated cable reinsertion. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. the following message is received: “Payload inaccessible . Occasionally. PLL calibration were affected by operating point configuration. Fixed the flow to issue software reset. IPv6 packets dropped while RoCE was enabled. Upon failure.06. InfiniBand loopback was blocked during link negotiation on the same port. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link.0 Release Notes o o o o o o o o o o o o o o o o o o o o o o o o o o o o Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI. On rare occasions. On rare occasions. Management transport was not supported. and not reach the Active state. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. Under certain conditions. On rare link reset occasions. Enhanced the receiver SerDes tuning for 10GE. an NMI event occurred on HP ALOM while trying to using the PXE CLI. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. Slow link establishment in NC-SI caused due to slow cable reading in boot. Port error counters were not cleared upon XAUI/SGMII link up. When changing link connection between 40Gbe to 10Gbe. the port might stay down until the next driver restart. Fixed a possible read access to DMA address 0x0.cannot continue”. after the driver was stopped. Fixed process voltage scaling issue. the second port may suffer a momentarily packet drop. When the same VLAN is configured for both ports and one port goes down. a failure occurred in speed when changing to Gen2.3200 for the below adapter types:  Rev B3 (PSID: HP_0250230018]  Rev B3 (PSID: HP_0240230019] 540 HP | Service Pack for ProLiant 2014.06. PXE might halt during teardown. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. On rare occasions.HP Service Pack for ProLiant 2014. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. SR-IOV guest experienced request timeouts and got stuck. after PXE driver teardown (unload). Fixed miss cqe issue due to interrupt moderation. Fixed a rare cable reading issue upon cable insertion. Fixed a possible access to unmapped resource memory. to support specific 10GbE QSFP to SFP+ splitter cables. Enhancements Includes firmware version 2. Gen2 failure at temperature sweep up to 10C/min (for MT27518A1-FDIR-BV only). PCIe Gen2 link unstable at temperature sweep of 10C/min for MT27518A1-FDIR-BV. SR-IOV guest experienced request timeouts and got stuck. When downgrading from firmware v2. Driver restart required when switching from InfiniBand FDR link with LLR enabled to InfiniBand link w/o LLR (for example: between SwitchX® and GD4036). On Pilot1 SL230. RH6. do you want to continue ? (y/n) [n] : y Fixes Fixes: o o o o Disabled MLPN in HP MEZZ QDR INI to allow 10GbE link with a 3rd party10GbE switch. The locked semaphore prevents the firmware from accessing the flash and causes firmware hang.0000 and using MFT 3. do you want to continue ? (y/n)[n] : y You are trying to restore default configuration. SBR should be asserted for a minimum of 50 milliseconds for the ConnectX®-3 adapters.0.5m FDR cable. support is not declared for this SFP to RJ45 module. When PCIe Gen3 is enabled. old FW configurations will be cleared. HP | Service Pack for ProLiant 2014.0.06. Auto-Sensing is not supported with 40GbE connections in VPI cards.8 (Recommended) Important Note! Known Issues: o o o o o o o o o o o o o o o o o o o o o MFT tools might leave the flash semaphore locked if the tool operation is forced stopped. Device managed Flow steering and NCSI cannot be enabled simultaneously.0 Release Notes Online Firmware Upgrade Utility (Windows x64) for HP Infiniband QDR/Ethernet 10Gb 2P 544i Adapter (SL4540 and SL4545 only) Version: 1. InfiniBand port_rcv_pkts counter presents wrong reporting when LLR is enabled on the port.0 541 . PXE is currently not supported in QSFP to SFP+ hybrid cable. Workaround: Clear the semaphore using MFT command: flint -clear_semaphore Although Link and Ping are established using this SFP to RJ45 module. If you continue. Bloom filter is currently not supported. A gap (LOS) between training sequences to data transmission causes peer partner to lose lock and fail ETH KR link. Cable Info MAD reports a wrong cable info when using the MC2210411-SR4 module. PXE is currently not supported in 40GbE in VPI cards. In a back-to-back setup of FDR cards connected with a 0. a FDR10 link is established instead of FDR. due to effects on link up/down on the adjacent port. VLAN filter is currently not supported. Occasionally. Enabled WoL on Port2 and disabled WoL on Port1 in ConnectX® HP Argos INI.11. 40GbE link takes longer to establish link when CR4 is used.HP Service Pack for ProLiant 2014. Ethernet cards fail to work with mlnx_ofed unless the do_sense is disabled in the INI.3 Inbox driver causes kernel panic when SR-IOV is enabled on VPI cards due to driver compatibility issue.0-3.0. Under certain conditions. the following message is displayed due to the mlxconfig tool: You are trying to override configurable FW by nonconfigurable FW. Workaround: Use other SFP to RJ45 adapters. Workaround: Production SL230 should be used for PCIe Gen3 operation. temporary correctable errors might occur when changing speed between PCIe Gen1 and PCIe Gen2.06. PCIe link occasionally does not come up at Gen3 speed. Fixed a rare cable reading issue upon cable insertion. On rare occasions. The device may enter an L1 power state before completing an incoming configuration request if it arrived before the power state change ack for Root Complex. Port error counters were not cleared upon XAUI/SGMII link up.2. On rare link reset occasions. Fixed the flow to issue software reset. When the same VLAN is configured for both ports and one port goes down. the second port may suffer a momentarily packet drop. Fixed a possible access to unmapped resource memory.cannot continue”. InfiniBand loopback was blocked during link negotiation on the same port.06. the following message is received: “Payload inaccessible . Slow link establishment in NC-SI caused due to slow cable reading in boot. a failure occurred in speed when changing to Gen2.0 . On rare occasions.3200 542 HP | Service Pack for ProLiant 2014. Fixed process voltage scaling issue. On rare occasions. to support specific 10GbE QSFP to SFP+ splitter cables. an NMI event occurred on HP ALOM while trying to using the PXE CLI.30. Fixed miss cqe issue due to interrupt moderation.0 Release Notes o o o o o o o o o o o o o o o o o o o o o o o o o Management transport was not supported.30. PXE boot fails due to a firmware issue interfering with the PXE load from the card's flash. Bad configuration of ib_protocol when setting the port to InfiniBand after exchanging it from Ethernet/RoCE on the same port. IPv6 packets dropped while RoCE was enabled. PXE might halt during teardown. Upon failure.06.HP Service Pack for ProLiant 2014. the port might stay down until the next driver restart. During repeated cable reinsertion. Enhanced the receiver SerDes tuning for 10GE. and not reach the Active state. the link may raise in a lower speed than expected. an NMI error is received when stopping PXE boot in the middle of an action on HP servers. When changing link connection between 40Gbe to 10Gbe. an HCA to SwitchX link may remain in ARM state after SwitchX reboot. The system was unresponsive when a race between PCI configuration cycles handling in hardware and firmware occurred. after PXE driver teardown (unload). Enhancements Includes firmware version 2. Updated the Revision ID of Node Info and General Info MADs to reflect hardware Rev ID instead of 0. after the driver was stopped. PLL calibration were affected by operating point configuration. Fixed a possible read access to DMA address 0x0.3200 for the below card:  Rev B3 (PSID: HP_0280110018] . Occasionally. Firmware Dependencies: None Enhancements/New Features: This is the initial version of the firmware.0 Release Notes Top Firmware .HP Service Pack for ProLiant 2014. Previous Revision: This is the initial version of the firmware.06.06.Power Management Online ROM Flash for Linux . Problems Fixed: None Known Issues: None 543 Enhancements HP | Service Pack for ProLiant 2014.1 (Recommended) Important Note! Important Notes: None Deliverable Name: Power Management Controller (HP ProLiant DL580 Gen8 Servers) Release Version: 4.0 .Power Management Controller (HP ProLiant DL580 Gen8 Servers) Version: 4.1 Last Recommended or Critical Revision: This is the initial version of the firmware. 0 Release Notes Important Notes: None Firmware Dependencies: None Enhancements/New Features: This is the initial version of the firmware.06. To prevent the impact to performance.3 (Recommended) Important Note! Important Notes: If a server has a Dynamic Power Cap enabled.Power Management Controller (HP ProLiant Gen8 Servers) Version: 3. the Dynamic Power Cap can be disabled prior to the flash update process. Known Issues: None Online ROM Flash for Linux .2 544 Firmware Dependencies: None HP | Service Pack for ProLiant 2014.0 .3 Last Recommended or Critical Revision: 3.HP Service Pack for ProLiant 2014. Deliverable Name: Power Management Controller (HP ProLiant Gen8 Servers) Release Version: 3. the server’s performance may be significantly affected during the duration of the flash update of the Power Management Controller Firmware.3 Previous Revision: 3.06. Power Management Controller (HP ProLiant DL580 Gen8 Servers) Version: 4.06.com/bizsupport/TechSupport/Document.hp. please consult this advisory at http://h20000. Known Issues: None Fixes Important Notes: If a server has a Dynamic Power Cap enabled. For a description of the issue and a list of affected platforms.jsp?locale=en_US&objectID= c03885073.HP Service Pack for ProLiant 2014.hp.0 .1 (Recommended) Important Note! 545 Important Notes: None HP | Service Pack for ProLiant 2014. the server’s performance may be significantly affected during the duration of the flash update of the Power Management Controller Firmware. please consult this advisory at http://h20000. Firmware Dependencies: None Problems Fixed: This firmware update addresses the issue described in Customer Advisory c03885073.jsp?locale=en_US&objectID= c03885073.06.www2.com/bizsupport/TechSupport/Document. Known Issues: None Online ROM Flash for Windows . the Dynamic Power Cap can be disabled prior to the flash update process.0 Release Notes Enhancements/New Features: None Problems Fixed: This firmware update addresses the issue described in Customer Advisory c03885073. For a description of the issue and a list of affected platforms. To prevent the impact to performance.www2. 06. Firmware Dependencies: None Enhancements/New Features: This is the initial version of the firmware.1 Last Recommended or Critical Revision: This is the initial version of the firmware. Problems Fixed: None Known Issues: None Prerequisites The "HP ProLiant iLO 3/4 Channel Interface Driver for Windows" must be installed and running before using this flash component. Previous Revision: This is the initial version of the firmware.HP Service Pack for ProLiant 2014.0 .06. You must install the iLO Channel Interface driver to use this component.0 Release Notes Deliverable Name: Power Management Controller (HP ProLiant DL580 Gen8 Servers) Release Version: 4. If the driver is not running you will receive the following error message: "The software is not supported for installation on this system." Enhancements Important Notes: None 546 Firmware Dependencies: HP | Service Pack for ProLiant 2014. 3 (Recommended) Important Note! Important Notes: If a server has a Dynamic Power Cap enabled. Deliverable Name: Power Management Controller (HP ProLiant Gen8 Servers) Release Version: 3. the Dynamic Power Cap can be disabled prior to the flash update process.06. To prevent the impact to performance.3 Last Recommended or Critical Revision: 3. Known Issues: None Online ROM Flash for Windows .3 Previous Revision: 3.0 .HP Service Pack for ProLiant 2014.Power Management Controller (HP ProLiant Gen8 Servers) Version: 3. the server’s performance may be significantly affected during the duration of the flash update of the Power Management Controller Firmware.2 Firmware Dependencies: None Enhancements/New Features: 547 None Problems Fixed: HP | Service Pack for ProLiant 2014.0 Release Notes None Enhancements/New Features: This is the initial version of the firmware.06. 06.SAS Storage Disk Online ROM Flash Component for VMware ESXi .www2. To prevent the impact to performance.DG0146FARVU. For a description of the issue and a list of affected platforms. DG0300BAMYR. DG0146BAMYQ. Firmware Dependencies: None Problems Fixed: This firmware update addresses the issue described in Customer Advisory c03885073.0 Release Notes This firmware update addresses the issue described in Customer Advisory c03885073. You must install the iLO Channel Interface driver to use this component. Known Issues: None Top Firmware . please consult this advisory at http://h20000. the Dynamic Power Cap can be disabled prior to the flash update process.jsp?locale=en_US&objectID= c03885073. and EG0300FAWJD Drives Version: HPDG (C) (Critical) HP | Service Pack for ProLiant 2014.hp. Known Issues: None Prerequisites The "HP ProLiant iLO 3/4 Channel Interface Driver for Windows" must be installed and running before using this flash component. please consult this advisory at http://h20000. the server’s performance may be significantly affected during the duration of the flash update of the Power Management Controller Firmware.HP Service Pack for ProLiant 2014.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID= c03885073.0 548 .06. EG0146FAWJC.hp. If the driver is not running you will receive the following error message: "The software is not supported for installation on this system.com/bizsupport/TechSupport/Document.www2. DG0300FARVV. For a description of the issue and a list of affected platforms." Fixes Important Notes: If a server has a Dynamic Power Cap enabled. Fixes Problems Fixed: o This firmware corrects a possible condition in which stale data might be written to the disk. Online ROM Flash Component for VMware ESXi . All other OSes would require an offline update using the SPP and HP SUM. The WRITE SAME command may be used during RAID ARRAY parity initialization. and EG0900FBLSK drives Version: HPD7 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. and VMware environments.0 Release Notes Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.06. Microsoft Windows. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. This results in unexpected data being returned in subsequent requests. All other OSes would require an offline update using the SPP and HP SUM.0 549 .06. and VMware environments. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5. EG0600FBLSH. After long term use of the HDD. This data issue has been duplicated in laboratory firmware stress tests. a rare condition might occur following a power cycle where the HP | Service Pack for ProLiant 2014. Customers who already installed firmware version HPDG do not need to update to HPDG(C). Fixes Problems Fixed: o o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. Only offline firmware flashing of drives is supported for these configurations. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Customers who already installed firmware version HPD7 do not need to update to HPD7(C). Only offline firmware flashing of drives is supported for these configurations.EG0300FBLSE.5. EG0450FBLSF.HP Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows. a RAID Controller may create false errors. Firmware version HPD3 prevents the drive from counting these false errors and eliminates the unwarranted SMART "Imminent Failure” or “Predictive Failure” message. Firmware version HPD7 prevents this condition from occurring. Fixes Problems Fixed: o o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. During a replacement drive rebuild process. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows. HP | Service Pack for ProLiant 2014. 550 Enhancements Enhancements/New Features: o Added support for VMware vSphere 5. All other OSes would require an offline update using the SPP and HP SUM. During a replacement drive rebuild process. Online ROM Flash Component for VMware ESXi . Customers who already installed firmware version HPD3 do not need to update to HPD3(C).5.06.HP Service Pack for ProLiant 2014. Firmware version HPD7 prevents the drive from counting these false errors and eliminates the unwarranted SMART "Imminent Failure” or “Predictive Failure” message. and VMware environments. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.0 .5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. The WRITE SAME command may be used during RAID ARRAY parity initialization. These false errors were improperly counted as true errors by the drive and resulted in a “SMART Imminent Failure” or “Predictive Failure” message. Only offline firmware flashing of drives is supported for these configurations.06. a RAID Controller may create false errors. which could potentially cause data loss or mechanical damage.EH0146FBQDC and EH0300FBQDD drives Version: HPD3 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. These false errors were improperly counted as true errors by the drive and resulted in a “SMART Imminent Failure” or “Predictive Failure” message.0 Release Notes o drive heads may land on areas of the disk containing data. HP Service Pack for ProLiant 2014.06.0 Release Notes o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - MB1000FAMYU and MB2000FAMYV Drives Version: HPD7 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD7 do not need to update to HPD7(C). Fixes Problem Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. The WRITE SAME command may be used during RAID ARRAY parity initialization. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - MM0500FBFVQ and MM1000FBFVR Drives Version: HPD8 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD8 do not need to update to HPD8(C). HP | Service Pack for ProLiant 2014.06.0 551 HP Service Pack for ProLiant 2014.06.0 Release Notes Fixes Problem Fixed: o o After long term use of the HDD, a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data, which could potentially cause data loss or mechanical damage. Firmware version HPD8 prevents this condition from occurring. This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. The WRITE SAME command may be used during RAID ARRAY parity initialization. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - DH0072FAQRD, DH0146FAQRE, EH0146FAWJB, and EH0072FAWJA Drives Version: HPDJ (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPDJ do not need to update to HPDJ(C). Fixes Problem Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. The WRITE SAME command may be used during RAID ARRAY parity initialization. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. HP | Service Pack for ProLiant 2014.06.0 552 HP Service Pack for ProLiant 2014.06.0 Release Notes Online ROM Flash Component for VMware ESXi - EF0300FARMU, EF0450FARMV, EF0600FARNA drive Version: HPD6 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD6 do not need to update to HPD6(C). Fixes Problems Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. The WRITE SAME command may be used during RAID ARRAY parity initialization. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - EF0300FATFD, EF0450FATFE, and EF0600FATFF Drives Version: HPDB (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPDB do not need to update to HPDB(C). Fixes Problems Fixed: HP | Service Pack for ProLiant 2014.06.0 553 HP Service Pack for ProLiant 2014.06.0 Release Notes o This firmware corrects a possible condition in which stale data might be written to the disk. This results in unexpected data being returned in subsequent requests. This data issue has been duplicated in laboratory firmware stress tests. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - EG0300FBDBR, EG0450FBDBT and EG0600FBDBU Drives Version: HPDA (D) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPDA do not need to update to HPDA(D). Fixes Firmware Dependency: o Minimum firmware required - HPD7. HPDA drive firmware will fail when downgrading to versions below HPD7. Problems Fixed: o This firmware corrects a possible condition in which stale data might be written to the disk. This results in unexpected data being returned in subsequent requests. This data issue has been duplicated in laboratory firmware stress tests. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. HP | Service Pack for ProLiant 2014.06.0 554 HP Service Pack for ProLiant 2014.06.0 Release Notes Online ROM Flash Component for VMware ESXi - EG0300FBDSP, EG0450FBDSQ, and EG0600FBDSR drives Version: HPD6 (C) (Optional) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD6 do not need to update to HPD6(C). Fixes Problems Fixed: o This firmware reduces the possibility of the controller and drive not properly negotiating link signaling, resulting in the controller not being able to identify a drive attached to a particular port/slot during system boot up. This firmware improves signal quality between the drive and the controller. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - EG0300FBVFL, EG0450FBVFM, EG0600FBVFP, and EG0900FBVFQ Drives Version: HPD9 (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD9 do not need to update to HPD9(B). Fixes Problems Fixed: HP | Service Pack for ProLiant 2014.06.0 555 HP Service Pack for ProLiant 2014.06.0 Release Notes o This firmware improves background scans for media robustness, and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - EG0300FCVBF, EG0450FCVBH, EG0600FCVBK, and EG0900FCVBL Drives Version: HPD5 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD5 do not need to update to HPD5(B). Fixes Problems Fixed: o This firmware contains a change which causes the drive hardware to send one Identify frame instead of three for a link reset to mitigate potential speed negotiation issues. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - EG1200FCVBQ Drives Version: HPD6 (B) (Critical) Important Note! 556 o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes o running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD6 do not need to update to HPD6(B). Fixes Problems Fixed: o This firmware improves background scans for media robustness, and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - EH0072FARUA and EH0146FARUB drives Version: HPD9 (C) (Optional) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD9 do not need to update to HPD9(C). Fixes Problems Fixed: o This firmware reduces the possibility of the controller and drive not properly negotiating link signaling, resulting in the controller not being able to identify a drive attached to a particular port/slot during system boot up. This firmware improves signal quality between the drive and the controller. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. HP | Service Pack for ProLiant 2014.06.0 557 HP Service Pack for ProLiant 2014.06.0 Release Notes Online ROM Flash Component for VMware ESXi - EH0072FARWC and EH0146FARWD Drives Version: HPDD (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPDD do not need to update to HPDD(C). Fixes Problems Fixed: o This firmware corrects a possible condition in which stale data might be written to the disk. This results in unexpected data being returned in subsequent requests. This data issue has been duplicated in laboratory firmware stress tests. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - EH0146FCBVB and EH0300FCBVC drives Version: HPD4 (C) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD4 do not need to update to HPD4(C). 558 Enhancements Enhancements/New Features: HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes o o o This firmware revision reduces the possibility of Uncorrectable Read Errors due to poor writes to the media. Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - EO0200FBRVV, MO0200FBRWB, EO0400FBRWA, MO0400FBRWC, and MO0800FBRWD drives Version: HPD9 (C) (Optional) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD9 do not need to update to HPD9(C). Fixes Problems Fixed: o In previous firmware revisions when the solid state drive was issued a Report Support Operation Code (RSOC) command (A3h) and the reporting options field was set to 001 , the drive incorrectly responded with 05/24/00 indicating that the RSOC command was not supported. The error was logged in the system log files. The drive should have communicated non-support using the Command Data Parameter (CDP) format. The firmware now complies with the RSOC industry standard specification. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - MB1000FBZPL and MB2000FBZPN drives Version: HPD3 (C) (Critical) Important Note! HP | Service Pack for ProLiant 2014.06.0 559 HP Service Pack for ProLiant 2014.06.0 Release Notes o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD3 do not need to update to HPD3(C). Fixes Problems Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. The WRITE SAME command may be used during RAID ARRAY parity initialization. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - MB1000FCWDE, MB2000FCWDF, MB3000FCWDH, and MB4000FCWDK drives Version: HPD5 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD5 do not need to update to HPD5(B). Fixes Problems Fixed: o This firmware contains a change which causes the drive hardware to send one Identify frame instead of three for a link reset to mitigate potential speed negotiation issues. Enhancements HP | Service Pack for ProLiant 2014.06.0 560 HP Service Pack for ProLiant 2014.06.0 Release Notes Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - MB2000FBUCL and MB3000FBUCN drives Version: HPDA (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPDA do not need to update to HPDA(B). Fixes Problems Fixed: o This firmware improves background scans for media robustness, and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - MB2000FCQPF and MB3000FBNWV Drives Version: HPD7 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD7 do not need to update to HPD7(B). HP | Service Pack for ProLiant 2014.06.0 561 HP Service Pack for ProLiant 2014.06.0 Release Notes Fixes Problems Fixed: o This firmware prevents a condition in which data failed to be written to media after the host issued a hard reset in a lab stress test environment with write cache enabled. Enhancements Enhancements/New Features: o o This firmware provides performance improvements for large transfer sequential write burst workloads. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for VMware ESXi - MM0500FAMYT Drives Version: HPD6 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD6 do not need to update to HPD6(C). Fixes Problem Fixed: o o After long term use of the HDD, a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data, which could potentially cause data loss or mechanical damage. Firmware version HPD6 prevents this condition from occurring. This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. The WRITE SAME command may be used during RAID ARRAY parity initialization. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. HP | Service Pack for ProLiant 2014.06.0 562 HP Service Pack for ProLiant 2014.06.0 Release Notes Online ROM Flash Component for VMware ESXi - MO0200FCTRN, MO0400FCTRP, and MO0800FCTRQ drives Version: HPD2 (C) (Optional) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD2 do not need to update to HPD2(C). Fixes Problems Fixed: o Resolved an intermittent issue where the drive would not report the progress of the sanitize command in return sense data. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.5. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online ROM Flash Component for Windows - DG0146FARVU, DG0300FARVV, DG0146BAMYQ, DG0300BAMYR, EG0146FAWJC, and EG0300FAWJD Drives Version: HPDG (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPDG do not need to update to HPDG(B). 563 Fixes Problems Fixed: o This firmware corrects a possible condition in which stale data might be written to the disk. This HP | Service Pack for ProLiant 2014.06.0 HP Service Pack for ProLiant 2014.06.0 Release Notes results in unexpected data being returned in subsequent requests. This data issue has been duplicated in laboratory firmware stress tests. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.sys) is running on the system being updated. Online ROM Flash Component for Windows - DH0072FAQRD, DH0146FAQRE, EH0146FAWJB, and EH0072FAWJA Drives Version: HPDJ (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPDJ do not need to update to HPDJ(B). Fixes Problem Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. The WRITE SAME command may be used during RAID ARRAY parity initialization. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.sys) is running on the system being updated. Online ROM Flash Component for Windows - EF0300FARMU, EF0450FARMV, EF0600FARNA drives Version: HPD6 (B) (Critical) Important Note! HP | Service Pack for ProLiant 2014.06.0 564 Only offline firmware flashing of drives is supported for these configurations. This data issue has been duplicated in laboratory firmware stress tests. HP | Service Pack for ProLiant 2014. Online ROM Flash Component for Windows .EF0300FATFD.06. This results in unexpected data being returned in subsequent requests.HP Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.sys) is running on the system being updated. Customers who already installed firmware version HPDB do not need to update to HPDB(B). Fixes Problems Fixed: o This firmware corrects a possible condition in which stale data might be written to the disk. Customers who already installed firmware version HPD6 do not need to update to HPD6(B). All other OSes would require an offline update using the SPP and HP SUM. EF0450FATFE. The WRITE SAME command may be used during RAID ARRAY parity initialization. All other OSes would require an offline update using the SPP and HP SUM. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments.06.0 565 . and EF0600FATFF Drives Version: HPDB (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Fixes Problems Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. Only offline firmware flashing of drives is supported for these configurations.0 Release Notes o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. and EG0600FBDSR drives Version: HPD6 (B) (Optional) HP | Service Pack for ProLiant 2014. Prerequisites o Minimum firmware required . Microsoft Windows. HPDA drive firmware will fail when downgrading to versions below HPD7. HPDA drive firmware will fail when downgrading to versions below HPD7. Online ROM Flash Component for Windows . Problems Fixed: o This firmware corrects a possible condition in which stale data might be written to the disk. EG0450FBDBT and EG0600FBDBU Drives Version: HPDA (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. EG0450FBDSQ.sys) is running on the system being updated.0 566 .HPD7. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. This data issue has been duplicated in laboratory firmware stress tests. Online ROM Flash Component for Windows .EG0300FBDSP.06.HP Service Pack for ProLiant 2014. Only offline firmware flashing of drives is supported for these configurations. This results in unexpected data being returned in subsequent requests. and VMware environments.EG0300FBDBR.HPD7. All other OSes would require an offline update using the SPP and HP SUM.0 Release Notes Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. Fixes Firmware Dependency: o Minimum firmware required . Customers who already installed firmware version HPDA do not need to update to HPDA(B).06. and EG0900FBLSK drives Version: HPD7 (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. EG0600FBLSH. The WRITE SAME command may be used during RAID ARRAY parity initialization. resulting in the controller not being able to identify a drive attached to a particular port/slot during system boot up. All other OSes would require an offline update using the SPP and HP SUM.HP Service Pack for ProLiant 2014.0 Release Notes Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Fixes Problems Fixed: o 567 This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.06. Customers who already installed firmware version HPD7 do not need to update to HPD7(B). Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. Customers who already installed firmware version HPD6 do not need to update to HPD6(B). All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations. EG0450FBLSF. HP | Service Pack for ProLiant 2014.EG0300FBLSE.06. Online ROM Flash Component for Windows . Fixes Problems Fixed: o This firmware reduces the possibility of the controller and drive not properly negotiating link signaling. This firmware improves signal quality between the drive and the controller. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.0 . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. Only offline firmware flashing of drives is supported for these configurations.sys) is running on the system being updated. and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data.0 . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Firmware version HPD7 prevents this condition from occurring. EG0450FCVBH. EG0600FBVFP.HP Service Pack for ProLiant 2014. HP | Service Pack for ProLiant 2014. and EG0900FCVBL Drives Version: HPD5 (Recommended) Important Note! o 568 Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Fixes Problems Fixed: o This firmware improves background scans for media robustness. EG0600FCVBK.sys) is running on the system being updated. All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations.0 Release Notes o o After long term use of the HDD.06.06. Online ROM Flash Component for Windows . a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. Microsoft Windows. These false errors were improperly counted as true errors by the drive and resulted in a “SMART Imminent Failure” or “Predictive Failure” message. which could potentially cause data loss or mechanical damage. Firmware version HPD7 prevents the drive from counting these false errors and eliminates the unwarranted SMART "Imminent Failure” or “Predictive Failure” message. a RAID Controller may create false errors.EG0300FBVFL. EG0450FBVFM.EG0300FCVBF. and EG0900FBVFQ Drives Version: HPD9 (Critical) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. Only offline firmware flashing of drives is supported for these configurations. and VMware environments. Online ROM Flash Component for Windows . During a replacement drive rebuild process. All other OSes would require an offline update using the SPP and HP SUM.0 Release Notes o Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Fixes Problems Fixed: o This firmware contains a change which causes the drive hardware to send one Identify frame instead of three for a link reset to mitigate potential speed negotiation issues. VMware ESXi.0 569 . Only offline firmware flashing of drives is supported for these configurations. Online ROM Flash Component for Windows . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data. All other OSes would require an offline update using the SPP and HP SUM. Online ROM Flash Component for Windows .06. and Microsoft Windows environments.06. Customers who already installed firmware version HPD9 do not need to update to HPD9(B). Microsoft Windows.EH0072FARUA and EH0146FARUB drives Version: HPD9 (B) (Optional) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. and VMware environments. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Only offline firmware flashing of drives is supported for these configurations. All other OSes would require an offline update using the SPP and HP SUM. HP | Service Pack for ProLiant 2014. Fixes Problems Fixed: o This firmware improves background scans for media robustness.HP Service Pack for ProLiant 2014.EG1200FCVBQ Drives Version: HPD6 (Critical) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. sys) is running on the system being updated.sys) is running on the system being updated. This firmware improves signal quality between the drive and the controller. All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations. This results in unexpected data being returned in subsequent requests.06. Customers who already installed firmware version HPDD do not need to update to HPDD(B). HP | Service Pack for ProLiant 2014. This data issue has been duplicated in laboratory firmware stress tests.HP Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.0 Release Notes Fixes Problems Fixed: o This firmware reduces the possibility of the controller and drive not properly negotiating link signaling. resulting in the controller not being able to identify a drive attached to a particular port/slot during system boot up.0 570 . Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.EH0072FARWC and EH0146FARWD Drives Version: HPDD (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.06. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. Online ROM Flash Component for Windows . Fixes Problems Fixed: o This firmware corrects a possible condition in which stale data might be written to the disk. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. Microsoft Windows. The WRITE SAME command may be used during RAID ARRAY parity initialization.EH0146FBQDC and EH0300FBQDD drives Version: HPD3 (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.HP Service Pack for ProLiant 2014.06.sys) is running on the system being updated. a RAID Controller may create false errors. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Online ROM Flash Component for Windows . All other OSes would require an offline update using the SPP and HP SUM. Fixes Problems Fixed: o o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.06. All other OSes HP | Service Pack for ProLiant 2014. and VMware environments. Only offline firmware flashing of drives is supported for these configurations. Firmware version HPD3 prevents the drive from counting these false errors and eliminates the unwarranted SMART "Imminent Failure” or “Predictive Failure” message. These false errors were improperly counted as true errors by the drive and resulted in a “SMART Imminent Failure” or “Predictive Failure” message.0 Release Notes Online ROM Flash Component for Windows .0 571 . Only offline firmware flashing of drives is supported for these configurations.EH0146FCBVB and EH0300FCBVC drives Version: HPD4 (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Customers who already installed firmware version HPD3 do not need to update to HPD3(B). Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. During a replacement drive rebuild process. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.0 . The drive should have communicated non-support using the Command Data Parameter (CDP) format. and MO0800FBRWD drives Version: HPD9 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.06.EO0200FBRVV. The firmware now complies with the RSOC industry standard specification. Fixes Problems Fixed: o In previous firmware revisions when the solid state drive was issued a Report Support Operation Code (RSOC) command (A3h) and the reporting options field was set to 001 . 572 HP | Service Pack for ProLiant 2014. MO0200FBRWB. Enhancements Enhancements/New Features: o This firmware revision reduces the possibility of Uncorrectable Read Errors due to poor writes to the media. Customers who already installed firmware version HPD9 do not need to update to HPD9(B). All other OSes would require an offline update using the SPP and HP SUM.HP Service Pack for ProLiant 2014. Only offline firmware flashing of drives is supported for these configurations. The error was logged in the system log files. Online ROM Flash Component for Windows . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments.sys) is running on the system being updated. MO0400FBRWC.06.0 Release Notes would require an offline update using the SPP and HP SUM. the drive incorrectly responded with 05/24/00 indicating that the RSOC command was not supported. EO0400FBRWA. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.MB1000FBZPL and MB2000FBZPN drives Version: HPD3 (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online ROM Flash Component for Windows . Customers who already installed firmware version HPD7 do not need to update to HPD7(B).HP Service Pack for ProLiant 2014. The WRITE SAME command may be used during RAID ARRAY parity initialization. Customers who already installed firmware version HPD3 do not need to update to HPD3(B). HP | Service Pack for ProLiant 2014.sys) is running on the system being updated. All other OSes would require an offline update using the SPP and HP SUM.06.0 Release Notes Online ROM Flash Component for Windows . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. All other OSes would require an offline update using the SPP and HP SUM. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments.0 573 . Only offline firmware flashing of drives is supported for these configurations. Fixes Problem Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive.06. Only offline firmware flashing of drives is supported for these configurations.MB1000FAMYU and MB2000FAMYV Drives Version: HPD7 (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. MB2000FCWDF.MB1000FCWDE.MB2000FBUCL and MB3000FBUCN drives Version: HPDA (Critical) Important Note! o 574 Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. HP | Service Pack for ProLiant 2014. Online ROM Flash Component for Windows . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. All other OSes would require an offline update using the SPP and HP SUM.06. Only offline firmware flashing of drives is supported for these configurations.sys) is running on the system being updated.06. VMware ESXi.HP Service Pack for ProLiant 2014. Only offline firmware flashing of drives is supported for these configurations. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. The WRITE SAME command may be used during RAID ARRAY parity initialization. Online ROM Flash Component for Windows . and Microsoft Windows environments. MB3000FCWDH. Fixes Problems Fixed: o This firmware contains a change which causes the drive hardware to send one Identify frame instead of three for a link reset to mitigate potential speed negotiation issues. and MB4000FCWDK drives Version: HPD5 (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.0 .0 Release Notes Fixes Problems Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. All other OSes would require an offline update using the SPP and HP SUM.HP Service Pack for ProLiant 2014.MM0500FAMYT Drives Version: HPD6 (B) (Critical) Important Note! o 575 Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Enhancements Enhancements/New Features: o This firmware provides performance improvements for large transfer sequential write burst workloads. Online ROM Flash Component for Windows .0 Release Notes o Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows.06. All other OSes would require an offline update using the SPP and HP SUM.06. Fixes Problems Fixed: o This firmware prevents a condition in which data failed to be written to media after the host issued a hard reset in a lab stress test environment with write cache enabled. Fixes Problems Fixed: o This firmware improves background scans for media robustness. and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data. Only offline firmware flashing of drives is supported for these configurations. Online ROM Flash Component for Windows . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. Only offline firmware flashing of drives is supported for these configurations. and VMware environments. HP | Service Pack for ProLiant 2014.0 .MB2000FCQPF and MB3000FBNWV Drives Version: HPD7 (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.sys) is running on the system being updated.HP Service Pack for ProLiant 2014. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD6 do not need to update to HPD6(B).06. which could potentially cause data HP | Service Pack for ProLiant 2014.0 . Firmware version HPD6 prevents this condition from occurring. Customers who already installed firmware version HPD8 do not need to update to HPD8(B). Only offline firmware flashing of drives is supported for these configurations.06. which could potentially cause data loss or mechanical damage. Fixes 576 Problem Fixed: o After long term use of the HDD.MM0500FBFVQ and MM1000FBFVR Drives Version: HPD8 (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. All other OSes would require an offline update using the SPP and HP SUM. The WRITE SAME command may be used during RAID ARRAY parity initialization. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. Fixes Problem Fixed: o o After long term use of the HDD.0 Release Notes o o Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. Online ROM Flash Component for Windows . Only offline firmware flashing of drives is supported for these configurations.06. DG0146BAMYQ. Online ROM Flash Component for Windows . Firmware version HPD8 prevents this condition from occurring. Supplemental Update / Online ROM Flash Component for Linux DG0146FARVU. DG0300FARVV. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. and EG0300FAWJD Drives Version: HPDG (C) (Critical) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. and VMware environments. and MO0800FCTRQ drives Version: HPD2 (Optional) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM.0 577 . Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. Microsoft Windows. All other OSes HP | Service Pack for ProLiant 2014. Only offline firmware flashing of drives is supported for these configurations. Fixes Problems Fixed: o Resolved an intermittent issue where the drive would not report the progress of the sanitize command in return sense data.MO0200FCTRN.06. DG0300BAMYR. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. and VMware environments. The WRITE SAME command may be used during RAID ARRAY parity initialization. EG0146FAWJC.sys) is running on the system being updated.0 Release Notes o loss or mechanical damage.HP Service Pack for ProLiant 2014. Microsoft Windows. MO0400FCTRP. HPD7. HPDA drive firmware will fail when downgrading to versions below HPD7. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. All other OSes would require an offline update using the SPP and HP SUM. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. EG0450FBDBT and EG0600FBDBU Drives Version: HPDA (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. HPDA drive firmware will fail when downgrading to versions below HPD7. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Prerequisites o Minimum firmware required .06.06. Supplemental Update / Online ROM Flash Component for Linux EG0300FBDBR. Customers who already installed firmware version HPDG do not need to update to HPDG(C). Fixes Problems Fixed: o o This firmware corrects a possible condition in which stale data might be written to the disk.HPD7.HP Service Pack for ProLiant 2014. Fixes Firmware Dependency: o Minimum firmware required . and VMware environments. Only offline firmware flashing of drives is supported for these configurations. Customers who already installed firmware version HPDA do not need to update to HPDA(C). This results in unexpected data being returned in subsequent requests.0 578 . Problems Fixed: HP | Service Pack for ProLiant 2014.0 Release Notes o would require an offline update using the SPP and HP SUM. This data issue has been duplicated in laboratory firmware stress tests. Microsoft Windows. Supplemental Update / Online ROM Flash Component for Linux EG0300FBDSP.0 Release Notes o This firmware corrects a possible condition in which stale data might be written to the disk. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. and EG0600FBDSR drives Version: HPD6 (C) (Optional) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD6 do not need to update to HPD6(C). Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux.0 579 .06.HP Service Pack for ProLiant 2014.06. This firmware improves signal quality between the drive and the controller. Microsoft Windows. Fixes Problems Fixed: o o This firmware reduces the possibility of the controller and drive not properly negotiating link signaling. This data issue has been duplicated in laboratory firmware stress tests. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. and EG0900FBLSK drives Version: HPD7 (C) (Critical) HP | Service Pack for ProLiant 2014. and VMware environments. EG0450FBLSF. EG0600FBLSH. Supplemental Update / Online ROM Flash Component for Linux EG0300FBLSE. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. resulting in the controller not being able to identify a drive attached to a particular port/slot during system boot up. This results in unexpected data being returned in subsequent requests. EG0450FBDSQ. Only offline firmware flashing of drives is supported for these configurations. Customers who already installed firmware version HPD7 do not need to update to HPD7(C). EG0450FBVFM. Fixes Problems Fixed: o o o o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. a RAID Controller may create false errors.HP Service Pack for ProLiant 2014. and VMware environments. Microsoft Windows. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Microsoft Windows. and EG0900FBVFQ drives Version: HPD9 (B) (Critical) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Firmware version HPD7 prevents the drive from counting these false errors and eliminates the unwarranted SMART "Imminent Failure” or “Predictive Failure” message. Only offline firmware flashing of drives is supported for these configurations. which could potentially cause data loss or mechanical damage.06. These false errors were improperly counted as true errors by the drive and resulted in a “SMART Imminent Failure” or “Predictive Failure” message. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Firmware version HPD7 prevents this condition from occurring. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. All other OSes would require an offline update using the SPP and HP SUM.0 Release Notes Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. HP | Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Supplemental Update / Online ROM Flash Component for Linux EG0300FBVFL. After long term use of the HDD. EG0600FBVFP. The WRITE SAME command may be used during RAID ARRAY parity initialization. All other OSes would require an offline update using the SPP and HP SUM. and VMware environments.06. During a replacement drive rebuild process. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures.0 580 . Only offline firmware flashing of drives is supported for these configurations. Fixes Problems Fixed: o This firmware improves background scans for media robustness.0 Release Notes o Customers who already installed firmware version HPD9 do not need to update to HPD9(B). Supplemental Update / Online ROM Flash Component for Linux EG1200FCVBQ drives Version: HPD6 (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers.06. Microsoft Windows. All other OSes would require an offline update using the SPP and HP SUM.HP Service Pack for ProLiant 2014. Fixes Problems Fixed: o This firmware improves background scans for media robustness. and VMware environments.0 581 . Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data. and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data. Customers who already installed firmware version HPD6 do not need to update to HPD6(B). Only offline firmware flashing of drives is supported for these configurations.06. Supplemental Update / Online ROM Flash Component for Linux EH0072FARUA and EH0146FARUB drives Version: HPD9 (C) (Optional) HP | Service Pack for ProLiant 2014. and VMware environments. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Fixes 582 Problems Fixed: o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. Only offline firmware flashing of drives is supported for these configurations. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Fixes Problems Fixed: o o This firmware reduces the possibility of the controller and drive not properly negotiating link signaling. Only offline firmware flashing of drives is supported for these configurations.0 . Customers who already installed firmware version HPD9 do not need to update to HPD9(C). All other OSes would require an offline update using the SPP and HP SUM. and VMware environments. This firmware improves signal quality between the drive and the controller. Microsoft Windows. Microsoft Windows. The WRITE SAME HP | Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux.06. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Customers who already installed firmware version HPD3 do not need to update to HPD3(C).06.HP Service Pack for ProLiant 2014. Supplemental Update / Online ROM Flash Component for Linux EH0146FBQDC and EH0300FBQDD drives Version: HPD3 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. resulting in the controller not being able to identify a drive attached to a particular port/slot during system boot up. All other OSes would require an offline update using the SPP and HP SUM.0 Release Notes Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. All other OSes would require an offline update using the SPP and HP SUM. and MO0800FBRWD drives Version: HPD9 (C) (Optional) 583 Important Note! o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero HP | Service Pack for ProLiant 2014. MO0200FBRWB.0 Release Notes o o command may be used during RAID ARRAY parity initialization. During a replacement drive rebuild process. Customers who already installed firmware version HPD4 do not need to update to HPD4(B). Firmware version HPD3 prevents the drive from counting these false errors and eliminates the unwarranted SMART "Imminent Failure” or “Predictive Failure” message.06. Added support for UEFI (Universal Extensible Firmware Interface) based servers. a RAID Controller may create false errors. These false errors were improperly counted as true errors by the drive and resulted in a “SMART Imminent Failure” or “Predictive Failure” message.0 . Supplemental Update / Online ROM Flash Component for Linux EH0146FCBVB and EH0300FCBVC drives Version: HPD4 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.HP Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Supplemental Update / Online ROM Flash Component for Linux EO0200FBRVV. EO0400FBRWA.06. MO0400FBRWC. Microsoft Windows. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Enhancements Enhancements/New Features: o o This firmware revision reduces the possibility of Uncorrectable Read Errors due to poor writes to the media. and VMware environments. Only offline firmware flashing of drives is supported for these configurations. The firmware now complies with the RSOC industry standard specification. The error was logged in the system log files.06. and VMware environments. Supplemental Update / Online ROM Flash Component for Linux MB1000FAMYU and MB2000FAMYV Drives Version: HPD7 (D) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM. HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. Fixes Problems Fixed: o o In previous firmware revisions when the solid state drive was issued a Report Support Operation Code (RSOC) command (A3h) and the reporting options field was set to 001 .0 Release Notes o o Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Fixes Problem Fixed: o 584 This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. The drive should have communicated non-support using the Command Data Parameter (CDP) format. Microsoft Windows. Only offline firmware flashing of drives is supported for these configurations. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux.06. and VMware environments.0 . All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD7 do not need to update to HPD7(D). Customers who already installed firmware version HPD9 do not need to update to HPD9(C). The WRITE SAME command may be used during RAID ARRAY parity initialization. Microsoft Windows. the drive incorrectly responded with 05/24/00 indicating that the RSOC command was not supported. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures.HP Service Pack for ProLiant 2014.0 585 . and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux.06.0 Release Notes o o HPD7 (B) resolves an issue with offline flashing where the component would time out during the upgrade process.06. Customers who already installed firmware version HPD3 do not need to update to HPD3(C). Supplemental Update / Online ROM Flash Component for Linux MM0500FAMYT Drives Version: HPD6 (C) (Critical) HP | Service Pack for ProLiant 2014. The WRITE SAME command may be used during RAID ARRAY parity initialization. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Fixes Problems Fixed: o o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Microsoft Windows. Supplemental Update / Online ROM Flash Component for Linux MB1000FBZPL and MB2000FBZPN drives Version: HPD3 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Customers who already installed firmware version HPD8 do not need to update to HPD8(C). Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Fixes HP | Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Supplemental Update / Online ROM Flash Component for Linux MM0500FBFVQ and MM1000FBFVR Drives Version: HPD8 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM.06. The WRITE SAME command may be used during RAID ARRAY parity initialization. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. Firmware version HPD6 prevents this condition from occurring. Only offline firmware flashing of drives is supported for these configurations.0 Release Notes Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Microsoft Windows. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows. Customers who already installed firmware version HPD6 do not need to update to HPD6(C). This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. and VMware environments. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Only offline firmware flashing of drives is supported for these configurations.HP Service Pack for ProLiant 2014. All other OSes would require an offline update using the SPP and HP SUM.0 586 . which could potentially cause data loss or mechanical damage. and VMware environments.06. Fixes Problem Fixed: o o o After long term use of the HDD. MO0400FCTRP. HP | Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Only offline firmware flashing of drives is supported for these configurations. Microsoft Windows. Customers who already installed firmware version HPD2 do not need to update to HPD2(C). Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. and MO0800FCTRQ drives Version: HPD2 (C) (Optional) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.06.0 587 . Firmware version HPD8 prevents this condition from occurring. which could potentially cause data loss or mechanical damage.0 Release Notes Problem Fixed: o o o After long term use of the HDD. The WRITE SAME command may be used during RAID ARRAY parity initialization.06. Fixes Problems Fixed: o Resolved an intermittent issue where the drive would not report the progress of the sanitize command in return sense data. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. Supplemental Update / Online ROM Flash Component for Linux MO0200FCTRN. All other OSes would require an offline update using the SPP and HP SUM. This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. and VMware environments.HP Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Supplemental Update / Online ROM Flash Component for Linux EF0300FARMU. Fixes Problem Fixed: o o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. EF0450FARMV. and VMware environments. and VMware environments. EH0146FAWJB.06.0 588 . Only offline firmware flashing of drives is supported for these configurations.0 Release Notes Supplemental Update / Online ROM Flash Component for Linux DH0072FAQRD. All other OSes would require an offline update using the SPP and HP SUM. Customers who already installed firmware version HPD6 do not need to update to HPD6(D). DH0146FAQRE. Microsoft Windows. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. and EH0072FAWJA Drives Version: HPDJ (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. Customers who already installed firmware version HPDJ do not need to update to HPDJ(C). Fixes Problems Fixed: HP | Service Pack for ProLiant 2014. and EF0600FARNA drives Version: HPD6 (D) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. The WRITE SAME command may be used during RAID ARRAY parity initialization.HP Service Pack for ProLiant 2014. Microsoft Windows. All other OSes would require an offline update using the SPP and HP SUM.06. but would fail to flash. This results in unexpected data being returned in subsequent requests.06.HP Service Pack for ProLiant 2014.06. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. HP | Service Pack for ProLiant 2014. Fixes Problems Fixed: o o This firmware corrects a possible condition in which stale data might be written to the disk. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures.0 Release Notes o o o This firmware prevents a rare condition that may occur during a WRITE SAME command sequence that may result in incorrect data being written to the hard drive. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. All other OSes would require an offline update using the SPP and HP SUM. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Microsoft Windows. was being detected. and EF0600FATFF Drives Version: HPDB (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Supplemental Update / Online ROM Flash Component for Linux EF0300FATFD. HPG6(C) resolved a component installation issue where the drive model. Only offline firmware flashing of drives is supported for these configurations. EF0450FATFE.0 589 . The WRITE SAME command may be used during RAID ARRAY parity initialization. Customers who already installed firmware version HPDB do not need to update to HPDB(C). EF0600FARNA. This data issue has been duplicated in laboratory firmware stress tests. and VMware environments. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. and VMware environments. This results in unexpected data being returned in subsequent requests. Only offline firmware flashing of drives is supported for these configurations. Only offline firmware flashing of drives is supported for these configurations. Fixes Problems Fixed: o This firmware contains a change which causes the drive hardware to send one Identify frame instead of three for a link reset to mitigate potential speed negotiation issues.0 .HP Service Pack for ProLiant 2014. Customers who already installed firmware version HPD5 do not need to update to HPD5(B). Supplemental Update / Online ROM Flash Component for Linux EH0072FARWC and EH0146FARWD Drives Version: HPDD (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM. and VMware environments. EG0450FCVBH.06. Customers who already installed firmware version HPDD do not need to update to HPDD(C).0 Release Notes Supplemental Update / Online ROM Flash Component for Linux EG0300FCVBF. EG0600FCVBK. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows. All other OSes would require an offline update using the SPP and HP SUM. Fixes 590 Problems Fixed: o This firmware corrects a possible condition in which stale data might be written to the disk. and EG0900FCVBL Drives Version: HPD5 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. This data issue has been HP | Service Pack for ProLiant 2014.06. Microsoft Windows. MB3000FCWDH.0 . Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. All other OSes would require an offline update using the SPP and HP SUM. and VMware environments. Supplemental Update / Online ROM Flash Component for Linux MB2000FBUCL and MB3000FBUCN drives Version: HPDA (B) (Critical) 591 Important Note! o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. MB2000FCWDF. Only offline firmware flashing of drives is supported for these configurations. Customers who already installed firmware version HPD5 do not need to update to HPD5(B). Only offline HP | Service Pack for ProLiant 2014. and MB4000FCWDK drives Version: HPD5 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Fixes Problems Fixed: o This firmware contains a change which causes the drive hardware to send one Identify frame instead of three for a link reset to mitigate potential speed negotiation issues. Microsoft Windows.HP Service Pack for ProLiant 2014.06.06.0 Release Notes o duplicated in laboratory firmware stress tests. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Supplemental Update / Online ROM Flash Component for Linux MB1000FCWDE. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Customers who already installed firmware version HPD7 do not need to update to HPD7(B). Fixes Problems Fixed: o This firmware prevents a condition in which data failed to be written to media after the host issued a hard reset in a lab stress test environment with write cache enabled.06. Customers who already installed firmware version HPDA do not need to update to HPDA(B). and also corrects a laboratory induced rare condition that could result in the disk not being updated with the latest cache data. and VMware environments.06. and VMware environments.HP Service Pack for ProLiant 2014. Supplemental Update / Online ROM Flash Component for Linux MB2000FCQPF and MB3000FBNWV Drives Version: HPD7 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM.0 Release Notes o o firmware flashing of drives is supported for these configurations. All other OSes would require an offline update using the SPP and HP SUM. Fixes Problems Fixed: o This firmware improves background scans for media robustness.0 592 . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Enhancements Enhancements/New Features: o o This firmware provides performance improvements for large transfer sequential write burst workloads. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Microsoft Windows. HP | Service Pack for ProLiant 2014. Microsoft Windows. Only offline firmware flashing of drives is supported for these configurations. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. 0 . HP | Service Pack for ProLiant 2014.MB0500GCEHF.HP Service Pack for ProLiant 2014. All other OSes would require an offline update using the SPP and HP SUM.06. MB1000GCEHH. Microsoft Windows.5. Only offline firmware flashing of drives is supported for these configurations. Only offline firmware flashing of drives is supported for these configurations. and MB2000GCEHK Drives Version: HPGD (C) (Critical) Important Note! o 593 Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online ROM Flash Component for VMware ESXi . the latter of which will result in the drive failed by the Controller or sub system.SATA Storage Disk Online ROM Flash Component for ESXi .MB3000EBKAB Drives Version: HPG6 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Customers who already installed firmware version HPG6 do not need to update to HPG6(C). and VMware environments. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Firmware version HPG6 prevents this condition from occurring. This firmware corrects “command timeouts” and seek errors which can result in poor performance or a Device Fault condition. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. which could potentially cause data loss or mechanical damage. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.06.0 Release Notes Top Firmware . Fixes Problems Fixed: o o After long term use of the HDD. MB3000ECWCT. and MB4000ECWCU Drives Version: HPG3 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM.06. and VMware environments. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5. Online ROM Flash Component for VMware ESXi .HP Service Pack for ProLiant 2014. Fixes Problems Fixed: o A correction to address failure to activate LED Activity which occurs during system boot. Microsoft Windows. and VMware environments.5. Fixes Problems Fixed: o After long term use of the HDD. which could potentially cause data loss or mechanical damage. MB2000ECWCR. Customers who already installed firmware version HPG3 do not need to update to HPG3(B). Added support for UEFI (Universal Extensible Firmware Interface) based servers. Improvement to allow drives to better handle sudden shock occurrences.0 Release Notes o o Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data.MB1000ECWCQ. Only offline firmware flashing of drives is supported for these configurations. Enhancements Enhancements/New Features: o o o 594 Frequency of Background Media Scans changed to reduce drive workload. Firmware version HPGD prevents this condition from occurring. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. New features to enhance telemetry of drive related issues and workload statistics during failure HP | Service Pack for ProLiant 2014.06. Customers who already installed firmware version HPGD do not need to update to HPGD(C). All other OSes would require an offline update using the SPP and HP SUM.0 . Microsoft Windows. Fixes Problems Fixed: o A correction to address failure to activate LED Activity which occurs during system boot. HP | Service Pack for ProLiant 2014. Microsoft Windows.0 Release Notes o analysis.06.MB2000EAZNL Drives Version: HPG4 (C) (Optional) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.06. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Enhancements Enhancements/New Features: o o o o Frequency of Background Media Scans changed to reduce drive workload.MB1000GCWCV. MB3000GCWDB. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Customers who already installed firmware version HPG4 do not need to update to HPG4(C). and VMware environments. Microsoft Windows. Improvement to allow drives to better handle sudden shock occurrences. and VMware environments. Online ROM Flash Component for VMware ESXi . and MB4000GCWDC Drives Version: HPGD (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Added support for UEFI (Universal Extensible Firmware Interface) based servers. All other OSes would require an offline update using the SPP and HP SUM. New features to enhance telemetry of drive related issues and workload statistics during failure analysis. Only offline firmware flashing of drives is supported for these configurations. Customers who already installed firmware version HPGD do not need to update to HPGD(B). All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations. Online ROM Flash Component for VMware ESXi . MB2000GCWDA.HP Service Pack for ProLiant 2014.0 595 . MB2000EBUCF and MB3000EBUCH Drives Version: HPG4 (C) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Microsoft Windows.HP Service Pack for ProLiant 2014. Online ROM Flash Component for VMware ESXi . Fixes Problems Fixed: o The system did not recognize some drives after a power-cycle.06. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux.06. Customers who already installed firmware version HPG4 do not need to update to HPG4(C).5. This is due to the drive initialization process being interrupted by a reset. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Drives built with or upgraded to hard drive firmware version HPG4 should not be downgraded to an earlier version of firmware due to hard drive manufacturing process changes. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5. Only offline firmware flashing of drives is supported for these configurations.0 Release Notes Fixes Problems Fixed: o This firmware contains general maintenance release and code improvement items. causing the drive to take more time than allotted to report commands. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5. All other OSes would require an offline update using the SPP and HP SUM. Added support for UEFI (Universal Extensible Firmware Interface) based servers.0 .5. 596 HP | Service Pack for ProLiant 2014. and VMware environments. very long periods of small range seeks).g. Only offline firmware flashing of drives is supported for these configurations. and VMware environments. Customers who already installed firmware version HPG2 do not need to update to HPG2(B). Customers who already installed firmware version HPG4 do not need to update to HPG4(C). MB3000ECVJH. could result in an increased drive failure rate for specific usage applications (e.0 597 .06.MB2000GBUPB and MB3000GBUCK drives Version: HPG4 (C) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. HP | Service Pack for ProLiant 2014. and MB4000ECVJK Drives Version: HPG2 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online ROM Flash Component for VMware ESXi . This is due to the drive initialization process being interrupted by a reset.0 Release Notes Online ROM Flash Component for VMware ESXi . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Only offline firmware flashing of drives is supported for these configurations. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Microsoft Windows. Microsoft Windows. which if not implemented.HP Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o o o This firmware improves reliability by modifying the pivot bearing grease wear leveling algorithm. Fixes Problems Fixed: o The system did not recognize some drives after a power-cycle.. and VMware environments. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. All other OSes would require an offline update using the SPP and HP SUM. causing the drive to take more time than allotted to report commands.06. Improvements in random read and write performance. All other OSes would require an offline update using the SPP and HP SUM.MB2000ECVJF. MB2000GCVBR. and VMware environments. which could potentially cause data loss or mechanical damage. Firmware version HPGJ prevents this condition from occurring. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. and MB4000GCVBU Drives Version: HPG2 (B) (Recommended) Important Note! o 598 Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.0 . Microsoft Windows.MB2000GCQXQ and MB3000GBKAC Drives Version: HPGJ (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Customers who already installed firmware version HPGJ do not need to update to HPGJ(C). Added support for UEFI (Universal Extensible Firmware Interface) based servers. Only offline firmware flashing of drives is supported for these configurations. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5. Online ROM Flash Component for VMware ESXi .06. All other OSes would require an offline update using the SPP and HP SUM. HP | Service Pack for ProLiant 2014. Fixes Problem Fixed: o After long term use of the HDD.0 Release Notes Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.HP Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Only offline firmware flashing of drives is supported for these configurations. Online ROM Flash Component for VMware ESXi .5.5. MB3000GCVBT.06. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. and VMware environments. Online ROM Flash Component for VMware ESXi . Added support for UEFI (Universal Extensible Firmware Interface) based servers. Improvements in random read and write performance. Only offline firmware flashing of drives is supported for these configurations. which could potentially cause data loss or mechanical damage. and VMware environments. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.0 599 . Added support for UEFI (Universal Extensible Firmware Interface) based servers.06. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data.0 Release Notes o o Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows.MM0500GBKAK and MM1000GBKAL Drives Version: HPGC (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Customers who already installed firmware version HPGC do not need to update to HPGC(C). All other OSes would require an offline update using the SPP and HP SUM.g. All other OSes would require an offline update using the SPP and HP SUM.06. which if not implemented. Fixes Problems Fixed: o After long term use of the HDD. Customers who already installed firmware version HPG2 do not need to update to HPG2(B).. Enhancements Enhancements/New Features: o o o This firmware improves reliability by modifying the pivot bearing grease wear leveling algorithm. Firmware version HPGC prevents this condition from occurring.5. HP | Service Pack for ProLiant 2014. Microsoft Windows.HP Service Pack for ProLiant 2014. very long periods of small range seeks). could result in an increased drive failure rate for specific usage applications (e. and MB2000GCEHK Drives Version: HPGD (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.sys) is running on the system being updated.HP Service Pack for ProLiant 2014. All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations. Only offline firmware flashing of drives is supported for these configurations. Customers who already installed firmware version HPGD do not need to update to HPGD(B). Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments.0 Release Notes Online ROM Flash Component for Windows . MB2000ECWCR.MB0500GCEHF.MB1000ECWCQ. Microsoft Windows.06. Firmware version HPGD prevents this condition from occurring.0 600 . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Online ROM Flash Component for Windows . a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data.06. MB1000GCEHH. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. and MB4000ECWCU Drives Version: HPG3 (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Fixes Problems Fixed: o After long term use of the HDD. Fixes HP | Service Pack for ProLiant 2014. All other OSes would require an offline update using the SPP and HP SUM. which could potentially cause data loss or mechanical damage. and VMware environments. MB3000ECWCT. MB2000GCWDA. • New features to enhance telemetry of drive related issues and workload statistics during failure analysis.0 Release Notes Problems Fixed: o A correction to address failure to activate LED Activity which occurs during system boot. Enhancements Enhancements/New Features: • Frequency of Background Media Scans changed to reduce drive workload.0 .HP Service Pack for ProLiant 2014. • New features to enhance telemetry of drive related issues and workload statistics during failure analysis. Enhancements Enhancements/New Features: • Frequency of Background Media Scans changed to reduce drive workload. Only offline firmware flashing of drives is supported for these configurations. MB3000GCWDB.06. Online ROM Flash Component for Windows .MB1000GCWCV. and MB4000GCWDC Drives Version: HPGD (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline HP | Service Pack for ProLiant 2014. • Improvement to allow drives to better handle sudden shock occurrences.06.MB2000EAZNL Drives Version: HPG4 (Optional) 601 Important Note! o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. Online ROM Flash Component for Windows . Fixes Problems Fixed: o A correction to address failure to activate LED Activity which occurs during system boot. All other OSes would require an offline update using the SPP and HP SUM. • Improvement to allow drives to better handle sudden shock occurrences. causing the drive to take more time than allotted to report commands.06. Microsoft Windows. and MB4000ECVJK Drives Version: HPG2 (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. and VMware environments. Fixes Problems Fixed: o The system did not recognize some drives after a power-cycle. Microsoft Windows. and VMware environments. MB3000ECVJH. Online ROM Flash Component for Windows . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows.MB2000ECVJF.0 Release Notes o firmware flashing of drives is supported for these configurations.06. Only offline firmware flashing of drives is supported for these configurations. Drives built with or upgraded to hard drive firmware version HPG4 should not be downgraded to an earlier version of firmware due to hard drive manufacturing process changes. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. This is due to the drive initialization process being interrupted by a reset. Fixes Problems Fixed: o This firmware contains general maintenance release and code improvement items.0 602 . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux.HP Service Pack for ProLiant 2014. All other OSes HP | Service Pack for ProLiant 2014. and VMware environments. Online ROM Flash Component for Windows .MB2000EBUCF and MB3000EBUCH Drives Version: HPG4 (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. All other OSes would require an offline update using the SPP and HP SUM. All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations.06. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. Only offline firmware flashing of drives is supported for these configurations.0 Release Notes would require an offline update using the SPP and HP SUM. HP | Service Pack for ProLiant 2014. causing the drive to take more time than allotted to report commands. and VMware environments. Improvements in random read and write performance.06. could result in an increased drive failure rate for specific usage applications (e. Fixes Problems Fixed: o The system did not recognize some drives after a power-cycle.MB2000GCQXQ and MB3000GBKAC Drives Version: HPGJ (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.HP Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o o This firmware improves reliability by modifying the pivot bearing grease wear leveling algorithm. All other OSes would require an offline update using the SPP and HP SUM.MB2000GBUPB and MB3000GBUCK Drives Version: HPG4 (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Customers who already installed firmware version HPGJ do not need to update to HPGJ(B). Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. very long periods of small range seeks). All other OSes would require an offline update using the SPP and HP SUM. This is due to the drive initialization process being interrupted by a reset..0 603 . which if not implemented.g. Online ROM Flash Component for Windows . Online ROM Flash Component for Windows . Microsoft Windows. and MB4000GCVBU Drives Version: HPG2 (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.MB3000EBKAB Drives Version: HPG6 (B) (Critical) 604 Important Note! o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero HP | Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. very long periods of small range seeks).06.0 Release Notes Fixes Problem Fixed: o After long term use of the HDD. Microsoft Windows.HP Service Pack for ProLiant 2014.06.. Firmware version HPGJ prevents this condition from occurring. All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations. Online ROM Flash Component for Windows .g. which could potentially cause data loss or mechanical damage.0 . Improvements in random read and write performance. MB3000GCVBT. and VMware environments. which if not implemented. Online ROM Flash Component for Windows . a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. could result in an increased drive failure rate for specific usage applications (e. Enhancements Enhancements/New Features: o o This firmware improves reliability by modifying the pivot bearing grease wear leveling algorithm.MB2000GCVBR.sys) is running on the system being updated. 06. Fixes Problems Fixed: o o After long term use of the HDD. a rare condition might occur following a power cycle where the HP | Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. Fixes 605 Problems Fixed: o After long term use of the HDD.MM0500GBKAK and MM1000GBKAL Drives Version: HPGC (B) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. This firmware corrects “command timeouts” and seek errors which can result in poor performance or a Device Fault condition. Firmware version HPG6 prevents this condition from occurring. the latter of which will result in the drive failed by the Controller or sub system. Customers who already installed firmware version HPG6 do not need to update to HPG6(B). Only offline firmware flashing of drives is supported for these configurations. Online ROM Flash Component for Windows . which could potentially cause data loss or mechanical damage. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data.0 . Customers who already installed firmware version HPGC do not need to update to HPGC(B).HP Service Pack for ProLiant 2014.sys) is running on the system being updated. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments. Only offline firmware flashing of drives is supported for these configurations.06. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments.0 Release Notes o o Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM. All other OSes would require an offline update using the SPP and HP SUM. Online ROM Flash Component for Windows . which could potentially cause data loss or mechanical damage. Customers who already installed firmware version HPG9 do not need to update to HPG9(B). All other OSes would require an offline update using the SPP and HP SUM. Fixes Problems Fixed: o This firmware corrects the possibility of the drive becoming unresponsive and requiring a power cycle following a soft system reboot. Only offline firmware flashing of drives is supported for these configurations. This behavior appears as if the drive is no longer attached to the system following the system soft reboot.06.VB0160EAVEQ and VB0160CBCDE Drives Version: HPG9 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments.sys) is running on the system being updated. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3. Firmware version HPGC prevents this condition from occurring. It is most often observed during Operating System Installation but can occur following any system soft reboot. Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.HP Service Pack for ProLiant 2014.0 606 .0 Release Notes drive heads may land on areas of the disk containing data.06.VB0250EAVER Drives Version: HPG9 (B) (Recommended) Important Note! HP | Service Pack for ProLiant 2014.sys) is running on the system being updated. Online ROM Flash Component for Windows . 0 607 . and VMware environments. Fixes Problems Fixed: o This firmware corrects the possibility of the drive becoming unresponsive and requiring a power cycle following a soft system reboot.06.sys) is running on the system being updated. All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations. Customers who already installed firmware version HPG9 do not need to update to HPG9(B). Microsoft Windows. This behavior appears as if the drive is no longer attached to the system following the system soft reboot. It is most often observed during Operating System Installation but can occur following any system soft reboot.06.0 Release Notes o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Fixes Problems Fixed: o This firmware corrects the possibility of the drive becoming unresponsive and requiring a power cycle following a soft system reboot. Only offline firmware flashing of drives is supported for these configurations. Supplemental Update / Online ROM Flash Component for ESXi . Enhancements Enhancements/New Features: o The firmware component installer can now install the drive firmware successfully when the new HP ProLiant Smart Array HPCISSS3 Controller Driver (hpcisss3.HP Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux and Microsoft Windows environments.VB0160EAVEQ and VB0160CBCDE Drives Version: HPG9 (C) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. This behavior appears as if the drive is no longer attached to the system following the system soft reboot. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Customers who already installed firmware version HPG9 do not need to update to HPG9(C). It is most often observed during Operating System HP | Service Pack for ProLiant 2014. All other OSes would require an offline update using the SPP and HP SUM. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5. Enhancements Enhancements/New Features: o o Added support for VMware vSphere 5.0 608 .5.HP Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Microsoft Windows.VB0250EAVER Drives Version: HPG9 (C) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM.06. Supplemental Update / Online ROM Flash Component for ESXi . This behavior appears as if the drive is no longer attached to the system following the system soft reboot. Customers who already installed firmware version HPG9 do not need to update to HPG9(C). Only offline firmware flashing of drives is supported for these configurations. and VMware environments. Fixes Problems Fixed: o This firmware corrects the possibility of the drive becoming unresponsive and requiring a power cycle following a soft system reboot.06. Supplemental Update / Online ROM Flash Component for Linux MB2000EAZNL drives Version: HPG4 (B) (Optional) Important Note! HP | Service Pack for ProLiant 2014. Added support for UEFI (Universal Extensible Firmware Interface) based servers.5. It is most often observed during Operating System Installation but can occur following any system soft reboot.0 Release Notes Installation but can occur following any system soft reboot. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux.HP Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers.06. Drives built with or upgraded to hard drive firmware version HPG4 should not be downgraded to an earlier version of firmware due to hard drive manufacturing process changes. Fixes Problems Fixed: o This firmware contains general maintenance release and code improvement items. Supplemental Update / Online ROM Flash Component for Linux MB2000EBUCF and MB3000EBUCH Drives Version: HPG4 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations. All other OSes would require an offline update using the SPP and HP SUM. Only offline firmware flashing of drives is supported for these configurations.06. Microsoft Windows. and VMware environments. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Enhancements Enhancements/New Features: HP | Service Pack for ProLiant 2014. Microsoft Windows. This is due to the drive initialization process being interrupted by a reset. Customers who already installed firmware version HPG4 do not need to update to HPG4(B).0 Release Notes o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Customers who already installed firmware version HPG4 do not need to update to HPG4(B).0 609 . Fixes Problems Fixed: o The system did not recognize some drives after a power-cycle. and VMware environments. causing the drive to take more time than allotted to report commands. All other OSes would require an offline update using the SPP and HP SUM. and VMware environments. Only offline firmware flashing of drives is supported for these configurations. MB1000GCEHH. Only offline firmware flashing of drives is supported for these configurations. Fixes Problems Fixed: o The system did not recognize some drives after a power-cycle. All other OSes would require an offline update using the SPP and HP SUM. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Customers who already installed firmware version HPG4 do not need to update to HPG4(B). Supplemental Update / Online ROM Flash Component for Linux MB2000GBUPB and MB3000GBUCK drives Version: HPG4 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. HP | Service Pack for ProLiant 2014. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows.06. and VMware environments.0 610 . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. causing the drive to take more time than allotted to report commands. Customers who already installed firmware version HPGD do not need to update to HPGD(E). This is due to the drive initialization process being interrupted by a reset. Supplemental Update / Online ROM Flash Component for Linux MB0500GCEHF. and MB2000GCEHK Drives Version: HPGD (E) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. All other OSes would require an offline update using the SPP and HP SUM.06.0 Release Notes o Added support for UEFI (Universal Extensible Firmware Interface) based servers.HP Service Pack for ProLiant 2014. Microsoft Windows. 06. Fixes Problems Fixed: o A correction to address failure to activate LED Activity which occurs during system boot. Firmware version HPGD prevents this condition from occurring.0 Release Notes Fixes Problems Fixed: o o o After long term use of the HDD. MB2000GCEHK.0 611 . Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. MB3000ECWCT. but would fail to flash. was being detected.06. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Supplemental Update / Online ROM Flash Component for Linux MB1000ECWCQ. HPGD (D) resolved a component installation issue where the drive model. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. Microsoft Windows. Improvement to allow drives to better handle sudden shock occurrences. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. MB2000ECWCR. New features to enhance telemetry of drive related issues and workload statistics during failure analysis. and MB4000ECWCU Drives Version: HPG3 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. which could potentially cause data loss or mechanical damage. HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o o o Frequency of Background Media Scans changed to reduce drive workload. Only offline firmware flashing of drives is supported for these configurations. Customers who already installed firmware version HPG3 do not need to update to HPG3(B). 06. Microsoft Windows. Only offline firmware flashing of drives is supported for these configurations. MB3000ECVJH. Only offline firmware flashing of drives is supported for these configurations. New features to enhance telemetry of drive related issues and workload statistics during failure analysis. and VMware environments. MB2000GCWDA. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows. Supplemental Update / Online ROM Flash Component for Linux MB2000ECVJF. Supplemental Update / Online ROM Flash Component for Linux MB1000GCWCV. All other OSes HP | Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o o o o Frequency of Background Media Scans changed to reduce drive workload.0 612 . Improvement to allow drives to better handle sudden shock occurrences. and MB4000ECVJK Drives Version: HPG2 (B) (Recommended) Important Note! o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. and MB4000GCWDC Drives Version: HPGD (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported.06. MB3000GCWDB.HP Service Pack for ProLiant 2014. Customers who already installed firmware version HPGD do not need to update to HPGD(B).0 Release Notes o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Fixes Problems Fixed: o A correction to address failure to activate LED Activity which occurs during system boot. All other OSes would require an offline update using the SPP and HP SUM. and VMware environments. and VMware environments. Firmware version HPGJ prevents this condition from occurring. Improvements in random read and write performance.. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. which could potentially cause data loss or mechanical damage. Fixes Problem Fixed: o o After long term use of the HDD.06. could result in an increased drive failure rate for specific usage applications (e. 613 HP | Service Pack for ProLiant 2014.06. which if not implemented. All other OSes would require an offline update using the SPP and HP SUM.0 . Customers who already installed firmware version HPGJ do not need to update to HPGJ(C). Enhancements Enhancements/New Features: o o o This firmware improves reliability by modifying the pivot bearing grease wear leveling algorithm. Added support for UEFI (Universal Extensible Firmware Interface) based servers. Only offline firmware flashing of drives is supported for these configurations. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data.0 Release Notes o would require an offline update using the SPP and HP SUM. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers.g. Microsoft Windows. Customers who already installed firmware version HPG2 do not need to update to HPG2(B). very long periods of small range seeks).HP Service Pack for ProLiant 2014. Supplemental Update / Online ROM Flash Component for Linux MB2000GCQXQ and MB3000GBKAC Drives Version: HPGJ (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. 0 614 . Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Microsoft Windows. and MB4000GCVBU Drives Version: HPG2 (B) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. and VMware environments.HP Service Pack for ProLiant 2014. Enhancements Enhancements/New Features: o o o This firmware improves reliability by modifying the pivot bearing grease wear leveling algorithm.g.06. Only offline firmware flashing of drives is supported for these configurations.0 Release Notes Supplemental Update / Online ROM Flash Component for Linux MB2000GCVBR. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Firmware version HPG6 prevents this condition from occurring. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. Improvements in random read and write performance. Microsoft Windows. Only offline firmware flashing of drives is supported for these configurations.. Customers who already installed firmware version HPG2 do not need to update to HPG2(B). Added support for UEFI (Universal Extensible Firmware Interface) based servers. Fixes Problems Fixed: o o After long term use of the HDD. Customers who already installed firmware version HPG6 do not need to update to HPG6(C). This firmware corrects “command timeouts” and seek errors which can result in poor HP | Service Pack for ProLiant 2014. could result in an increased drive failure rate for specific usage applications (e. Supplemental Update / Online ROM Flash Component for Linux MB3000EBKAB Drives Version: HPG6 (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. which could potentially cause data loss or mechanical damage. which if not implemented. very long periods of small range seeks).06. and VMware environments. All other OSes would require an offline update using the SPP and HP SUM. All other OSes would require an offline update using the SPP and HP SUM. MB3000GCVBT. Only offline firmware flashing of drives is supported for these configurations. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. a rare condition might occur following a power cycle where the drive heads may land on areas of the disk containing data. Customers who already installed firmware version HPGC do not need to update to HPGC(C). Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers.06.06. the latter of which will result in the drive failed by the Controller or sub system. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers.HP Service Pack for ProLiant 2014. Supplemental Update / Online ROM Flash Component for Linux MM0500GBKAK and MM1000GBKAL Drives Version: HPGC (C) (Critical) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Fixes Problems Fixed: o o After long term use of the HDD. All other OSes would require an offline update using the SPP and HP SUM.0 615 . Supplemental Update / Online ROM Flash Component for Linux VB0160EAVEQ and VB0160CBCDE Drives Version: HPG9 (C) (Recommended) HP | Service Pack for ProLiant 2014. Firmware version HPGC prevents this condition from occurring.0 Release Notes o performance or a Device Fault condition. Microsoft Windows. and VMware environments. which could potentially cause data loss or mechanical damage. Microsoft Windows. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers. Fixes Problems Fixed: o o This firmware corrects the possibility of the drive becoming unresponsive and requiring a power cycle following a soft system reboot. All other OSes would require an offline update using the SPP and HP SUM. All other OSes would require an offline update using the SPP and HP SUM.0 . This behavior appears as if the drive is no longer attached to the system following the system soft reboot. Only offline firmware flashing of drives is supported for these configurations. and VMware environments.06. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux. This behavior appears as if the drive is no longer attached to HP | Service Pack for ProLiant 2014. Fixes 616 Problems Fixed: o This firmware corrects the possibility of the drive becoming unresponsive and requiring a power cycle following a soft system reboot. It is most often observed during Operating System Installation but can occur following any system soft reboot.0 Release Notes Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Supplemental Update / Online ROM Flash Component for Linux VB0250EAVER Drives Version: HPG9 (C) (Recommended) Important Note! o o o Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Microsoft Windows. and VMware environments. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. Customers who already installed firmware version HPG9 do not need to update to HPG9(C). Customers who already installed firmware version HPG9 do not need to update to HPG9(C).HP Service Pack for ProLiant 2014. Only offline firmware flashing of drives is supported for these configurations.06. 06. I/O module A of one enclosure is connected to I/O module A of the subsequent enclosure. both I/O modules of the target disk enclosure and cascaded disk HP | Service Pack for ProLiant 2014. Top Firmware .0 617 .06. Enhancements Enhancements/New Features: o Added support for UEFI (Universal Extensible Firmware Interface) based servers.Storage Controller Firmware CD Supplemental Update / Online ROM Flash Component for Linux Smart Array P600 Version: 2. I/O module A in the cascaded disk enclosures is automatically updated. It is most often observed during Operating System Installation but can occur following any system soft reboot. Fixed an issue where Sequential reads on SATA drives in an HP StorageWorks MSA60 may lead to drive failures.0 Release Notes o the system following the system soft reboot.HP Service Pack for ProLiant 2014. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit. HP D2600/D2700 6Gb SAS Disk Enclosure ROM Flash Component for Linux Version: 0149 (B) (Recommended) Important Note! IMPORTANT:Firmware updates must be performed during a system maintenance window.04 (A) (Recommended) Important Note! Fixes o o Fixed an issue where incorrect data may be returned for a SCSI MODE SENSE command sent to a SATA drive. NOTE: When disk enclosures are cascaded. It typically takes several minutes for the firmware to load. NOTE: In dual-domain configurations. During a firmware update. with all I/O to the system halted. Flashing drives connected behind an HP H2xx Host Bus Adapter (HBA) no longer causes an interrupt resulting in drive firmware installation failures. I/O module A in the cascaded disk enclosures is automatically updated. NOTE: All firmware flash progress messages are logged to /var/cpq/Component. NOTE: All firmware flash progress messages are logged to /var/cpq/Component.0 . During a firmware update.log for network flash. NOTE: In dual-domain configurations. Prerequisites IMPORTANT: Firmware updates must be performed during a system maintenance window.log for network flash. with all I/O to the system halted.06. Fixed an issue where a drive insertion might not correctly illuminate the LEDs. Supported Devices and Features The D2600/ D2700 Enclosure can be attached to any of the following HP Smart Array storage controllers: o o o o o o o o o HP Smart Array P431 controller HP Smart Array P212 controller HP Smart Array P411 controller HP Smart Array P812 controller HP Smart Array P222 controller HP Smart Array P421 controller HP Smart Array P822 controller HP H221 Host Bus Adapter HP H222 Host Bus Adapter Alternatively. Fixes The following items were fixed in firmware 0149: o o Fixed an issue where a small percentage of UID button presses did not register correctly. I/O module A of one enclosure is connected to I/O module A of the subsequent enclosure. NOTE: When disk enclosures are cascaded.log for inband and /var/cpq/MSA2000_ip. it can also be connected behind a HP MSA 2040/1040 and P2000 G3 arrays. 618 HP | Service Pack for ProLiant 2014.06. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit.0 Release Notes enclosures are automatically updated during the firmware installation process. It typically takes several minutes for the firmware to load.HP Service Pack for ProLiant 2014. both I/O modules of the target disk enclosure and cascaded disk enclosures are automatically updated during the firmware installation process.log for inband and /var/cpq/MSA2000_ip. NOTE: In dual-domain configurations. with all I/O to the system halted. with all I/O to the system halted. both I/O modules of the target disk enclosure and cascaded disk enclosures are automatically updated during the firmware installation process. I/O module A in the cascaded disk enclosures is automatically updated. NOTE: In dual-domain configurations. I/O module A of one enclosure is connected to I/O module A of the subsequent enclosure. NOTE: When disk enclosures are cascaded.0 Release Notes HP D2600/D2700 6Gb SAS Disk Enclosure ROM Flash Component for Windows Version: 0149 (B) (Recommended) Important Note! IMPORTANT: Firmware updates must be performed during a system maintenance window. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit. It typically takes several minutes for the firmware to load. It typically takes several minutes for the firmware to load.HP Service Pack for ProLiant 2014. During a firmware update.06. Prerequisites IMPORTANT: Firmware updates must be performed during a system maintenance window. both I/O modules of the target disk enclosure and cascaded disk enclosures are automatically updated during the firmware installation process. Fixes The following items were fixed in firmware 0149: o o Fixed an issue where a small percentage of UID button presses did not register correctly.06.0 . Fixed an issue where a drive insertion might not correctly illuminate the LEDs. Supported Devices and Features The D2600/ D2700 Enclosure can be attached to any of the following HP Smart Array storage controllers: o o o o o o HP Smart Array P431 controller HP Smart Array P212 controller HP Smart Array P411 controller HP Smart Array P812 controller HP Smart Array P222 controller HP Smart Array P421 controller 619 HP | Service Pack for ProLiant 2014. I/O module A of one enclosure is connected to I/O module A of the subsequent enclosure. I/O module A in the cascaded disk enclosures is automatically updated. During a firmware update. NOTE: When disk enclosures are cascaded. WARNING! Do not power cycle or restart during the firmware update as this can result in loss of capabilities for this unit. H210i and H220i Version: 15.0 620 .10 FW on your HP SAS Expander Card.HP Service Pack for ProLiant 2014.HP SAS Expander Card Version: 2.10 FW on your HP SAS Expander Card. the HP SAS Expander. HP | Service Pack for ProLiant 2014. When the HP SAS Expander was unresponsive. Enhancements Enhancements/New Features: o Resolved an issue where the Smart Component would hang during hardware discovery when an unknown device was present.10 (B) (Recommended) Prerequisites A minimum FW version 3.00 (Recommended) Fixes Problems Fixed: o o Addresses a SAS discovery error that could occur during POST when the HP H221 or H222 Host Bus Adapter controllers are connected to an external JBOD.06. H221. Addresses box numbering issue (numbering not displayed on back of display of HP D3000 enclosure) when H2xx HBA's are connected to an HP D3000 enclosure. it can also be connected behind a HP MSA 2040/1040 and P2000 G3 arrays. would be unresponsive.06. Offline Firmware Supplemental Update . Fixes Firmware Dependency: A minimum FW version 3. Online ROM Flash Component for Linux . Problems Fixed: o On rare occasions during a power-up sequence. H222.66 is required on your HP Smart Array controller when updating to 2.06. the attached HP Smart Array P410 or P410i Controller was not allowed to discover drives that were attached.66 is required on your HP Smart Array controller when updating to 2.HP Host Bus Adapters H220.0 Release Notes o o o HP Smart Array P822 controller HP H221 Host Bus Adapter HP H222 Host Bus Adapter Alternatively.10. P711m.40(B) added support for VMware vSphere 5.0. P410. P712m.0 Release Notes Online ROM Flash Component for VMware ESXi . Note: Version 6.40 do not need to update to 6. P411. by pressing the escape keystrokes “Esc+6” or "F6" or “Esc+8” or "F8" via the BIOS Serial Console.40(B): o Fixed an installation issue where version 6.40 (B) (Recommended) Important Note! o Customers who already installed firmware version 6. The POST was indicateding a bad Super-Cap.HP Service Pack for ProLiant 2014.06.Smart Array P212.40 is no longer available for download from HP Support Center. Enhancements Enhancements/New Features: o o Allow Windows Server 2012 drivers to utilize command addressing above the lower 4GB memory region when requested by the storage driver.06. Important Notes: o Reference Customer Advisory c03793656 . Customers could not invoke ORCA via command line interface.76 or greater.Windows Server 2012 .40 of the Online Smart Array firmware smart components for the Smart Array P410i Controller would in some cases update the SAS expander in the HP D2200sb Storage Blade with incorrect firmware causing the Smart Array P410i Controller to be unable to communicate with the hard drives installed in the HP D2200sb Storage Blade.SYS Driver Version 62. but the following fixes are also provided in version 6. and P812 Version: 6.0 . P410i. Version 6.40(B).5.HP ProLiant Server May Blue Screen if Configured With an HP Smart Array Controller and the Windows Server 2012 HPCISSS2.40 (B). which in turn disabled write caching. On rare occasions the controller would become unresponsive during POST.40: o o o o False POST 1705 messages were being posted on the HP BL465c G7 or HP BL685c G7 Blade systems that used HP Smart Array P410i controller firmware version 5. On intermittent occasions. 621 HP | Service Pack for ProLiant 2014. Reference Customer Advisory c03964262 for additional important information about this issue. Problems Fixed in version 6.64 Fixes Problems Fixed in version 6.26. SATA spare drives in a JBOD were being marked as hot removed and then rediscovered. and P822 Version: 5. P421.06. An issue that prevented the spare drive Online LED from blinking if one data drive is failed during a RAID migration. incorrect drive temperatures were reported in an HP D2220sb enclosure. P431.HP Service Pack for ProLiant 2014. P430. New 4GiB Controller cache module option. The logging of an invalid Smart Array controller failure following a kdump or kexec. A controller lockup could occur if the controller was configured with a SmartCache smaller than 8GB.0 Release Notes Online ROM Flash Component for VMware ESXi . An issue that prevented HP SSD SmartPath from being enabled in certain scenarios. P222. P420i.Smart Array P230i. An issue that could lead to the controller’s read/write cache being disabled in certain scenarios. P420. UEFI (Universal Extensible Firmware Interface). P830i. Improved RAID 1 performance for small block random write workloads on SSD configurations. Online ROM Flash Component for VMware ESXi . SSD Over-provision Optimization (OPO). resulting in a system shutdown. VMware might hang when a VM with 2 or more RDMs used a Smart Array controller to access an HP P2000 G3 or HP MSA 2040 SAN storage device.42 (Recommended) Fixes Problems Fixed: The following issues are resolved with firmware version 5.06. In some cases.50 (Recommended) Fixes Problems Fixed: o o o o o o o An intermittent issue that can result in the system fans going to maximum speed during certain heavy IO loads. and P830 Version: 1. An issue which prevented the configuration of a maximum size HP SmartCache. P731m.42: o o o o o o Communication between the HP Integrated Lights-Out (iLO) and the HP Smart Array controller may be lost resulting in an IML entry indicating a failed controller. On some power cycles. P721m.0 . Enhancements Enhancements/New Features: Added support for following new features: 622 o o o o HP Secure Encryption.Smart Array P220i. Loss of redundant paths following an update of HP D2600/D2700 firmware. even though charging had completed. the supercap would always report that it was charging. HP | Service Pack for ProLiant 2014. and Microsoft Windows environments.0 Release Notes o o 512e (Advanced Format) hard drives.HP Service Pack for ProLiant 2014. Fixes Problems Fixed: o o Fixed an issue with the SAS connector element which reported invalid connector type/physical link for disabled PHYs.06. Online ROM Flash Component for VMware ESXi – HP Gen8 Server Backplane Expander Firmware for HP Smart Array Controllers and HP HBA Controllers Version: 3. VMware ESXi. Resolves SAS link errors that may occur with cascaded HP D6000 disk enclosures (limited support for cascading). Added multi-drive RAID-0 sequential write performance enhancements. Online ROM Flash Component for VMware ESXi – HP D6000 Disk Enclosure Version: 2. All other OSes would require an offline update using the SPP and HP SUM. Fixed the Logical Link Rate because the Rate was not set properly when PHY is disabled. Increased SAS phy error monitoring capabilities of the controller. SAS drive link rates are still 6G. 623 HP | Service Pack for ProLiant 2014.30 (Recommended) Important Note! o Online backplane expander firmware update available for Smart Array Controllers configured in systems running supported Linux.06.54 (Recommended) Fixes Problems Fixed: o o o o Improved signal integrity settings to reduce the occurrence of PHY DWORD errors when using HP D6000 Disk Enclosures.0 . Limits the SATA drive link rate to 3G. Additional rebuild priorities. Resolves a Smart Array controller 0xAB lockup observed during SAS switch reboots in HP BladeSystem configurations. the following enhancements were made: o o o Made changes to improve performance of low queue depth workloads. Additionally. 0 624 .0 Release Notes Online ROM Flash Component for Windows . Resolves a Smart Array controller 0xAB lockup observed during SAS switch reboots in HP BladeSystem configurations. Customers who already installed firmware version 0. All other OSes would require an offline update using the SPP and HP SUM.54 (Recommended) Fixes Problems Fixed: o o o o Improved signal integrity settings to reduce the occurrence of PHY DWORD errors when using HP D6000 Disk Enclosures.HP D6000 Disk Enclosure Version: 2.30 (Recommended) HP | Service Pack for ProLiant 2014. Online ROM Flash Component for Windows . Online ROM Flash Component for Windows .44 (B). Problems Fixed in version 0. Fixes Problems Fixed in version 0.HP 512MB Flash Backed Write Cache for B-Series Smart Array Version: 0. SAS drive link rates are still 6G.44: o Prior to version 0. This firmware now detects cache module charging circuit failures and displays a new POST 1813 error that correctly instructs the user to replace the cache module.44.HP Gen8 Server Backplane Expander Firmware for HP Smart Array Controllers and HP HBA Controllers Version: 3.HP Service Pack for ProLiant 2014.44 do not need to update to 0.06. Resolves SAS link errors that may occur with cascaded HP D6000 disk enclosures (limited support for cascading).44(B): o Resolved an issue where the Smart Component would hang during hardware discovery when an unknown device was present. a cache module charging circuit failure would result in an incorrect POST 1705 error indicating the super-cap should be replaced.06.44 (B) (Optional) Important Note! o o Online firmware update available for systems running supported Linux and Microsoft Windows environments. Limits the SATA drive link rate to 3G. Online ROM Flash Component for Windows . and Microsoft Windows environments. H210i and H220i Version: 15.0 . Fixes Problems Fixed: o o Fixed an issue with the SAS connector element which reported invalid connector type/physical link for disabled PHYs.06.06.86 do not need to update to 1.10.Smart Array E200 and E200i Version: 1. Addresses box numbering issue (numbering not displayed on back of display of HP D3000 enclosure) when H2xx HBA's are connected to an HP D3000 enclosure.05. H222.HP Service Pack for ProLiant 2014.0 Release Notes Important Note! o Online backplane expander firmware update available for Smart Array Controllers configured in systems running supported Linux. Online ROM Flash Component for Windows . All other OSes would require an offline update using the SPP and HP SUM.00 (Recommended) Fixes Problems Fixed: o o Addresses a SAS discovery error that could occur during POST when the HP H221 or H222 Host Bus Adapter controllers are connected to an external JBOD.86(C).10. H221.HP Host Bus Adapters H220.00 (Recommended) Fixes Problems Fixed: The following issues are resolved in this version of the firmware: o Resolves the I/O errors and/or inability to access solid state drives (SSD) on systems using the HP Smart Array B320i RAID controller and certain SSDs.86 (C) (Critical) 625 Important Note! Customers who already installed firmware version 1. Online ROM Flash Component for Windows . Fixed the Logical Link Rate because the Rate was not set properly when PHY is disabled.06.HP Smart Array B320i RAID controller Version: 15. HP | Service Pack for ProLiant 2014. VMware ESXi. Updating the HP MSA 60 and/or MSA 70 firmware version to 2.24(B) .0 Release Notes Fixes Problems Fixed: o o o Fixed an issue where logical drives were not being detected during POST or reboot on the HP Smart Array E200i controller with firmware version 1. This would cause the component installation to end with a return code 3 (already up to date) and a force install would be required to successfully update the FW. HP | Service Pack for ProLiant 2014.24 do not need to update to 7. 1.06. Prerequisites   Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs. Problems Fixed: o o Resolved an issue where the server’s system event log would fill with Event ID 129 warnings and the Smart Array controller would become unresponsive.06.86(C) . Online ROM Flash Component for Windows . Updating the HP MSA 60 and/or MSA 70 firmware version to 2. Fixed an issue that caused the component to hang during installation under a Japanese Language version of the OS. FW version 1.82 or 1.Fixed an issue where a decimal conversion was not being interpreted correctly when installing the component under certain regional settings in Windows.Fixed an issue where a decimal conversion was not being interpreted correctly when installing the component under certain regional settings in Windows.HP Service Pack for ProLiant 2014.24(B).24 (B) (Recommended) Important Note! Customers who already installed firmware version 7.0 626 .84.16 or higher is required to enable dual domain functionality Fixes Firmware Dependency: o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs. This would cause the component installation to end with a return code 3 (already up to date) and a force install would be required to successfully update the FW. FW version 7.Smart Array E500 Version: 7.16 or higher is required to enable dual domain functionality.80. 40(B).HP Service Pack for ProLiant 2014.06. 627 HP | Service Pack for ProLiant 2014. On rare occasions the controller would become unresponsive during POST. Note: Version 6.Smart Array P212.40 do not need to update to 6.0. and P812 Version: 6.HP ProLiant Server May Blue Screen if Configured With an HP Smart Array Controller and the Windows Server 2012 HPCISSS2. SATA spare drives in a JBOD were being marked as hot removed and then rediscovered.40(B): o Fixed an installation issue where version 6. Reference Customer Advisory c03964262 for additional important information about this issue.0 Release Notes Online ROM Flash Component for Windows . On intermittent occasions.26. but the following fixes are also provided in version 6.40: o o o o False POST 1705 messages were being posted on the HP BL465c G7 or HP BL685c G7 Blade systems that used HP Smart Array P410i controller firmware version 5. P410i. P711m.40 (B) (Recommended) Important Note! o Customers who already installed firmware version 6.40 of the Online Smart Array firmware smart components for the Smart Array P410i Controller would in some cases update the SAS expander in the HP D2200sb Storage Blade with incorrect firmware causing the Smart Array P410i Controller to be unable to communicate with the hard drives installed in the HP D2200sb Storage Blade. Important Notes: o Reference Customer Advisory c03793656 .0 . by pressing the escape keystrokes “Esc+6” or "F6" or “Esc+8” or "F8" via the BIOS Serial Console.40 is no longer available for download from HP Support Center. The POST was indicateding a bad Super-Cap. P712m.SYS Driver Version 62.Windows Server 2012 . Problems Fixed in version 6.06. P410. Enhancements Enhancements/New Features: o Allow Windows Server 2012 drivers to utilize command addressing above the lower 4GB memory region when requested by the storage driver. which in turn disabled write caching. P411.40 (B).76 or greater. Customers could not invoke ORCA via command line interface.64 Fixes Problems Fixed in version 6. An issue that could lead to the controller’s read/write cache being disabled in certain scenarios. and P830 Version: 1.06.Smart Array P220i. resulting in a system shutdown. HP | Service Pack for ProLiant 2014. The logging of an invalid Smart Array controller failure following a kdump or kexec. P431. An issue that prevented HP SSD SmartPath from being enabled in certain scenarios.Smart Array P230i. Enhancements Enhancements/New Features: Added support for following new features: 628 o o o o HP Secure Encryption. and P822 Version: 5. incorrect drive temperatures were reported in an HP D2220sb enclosure. P421.HP Service Pack for ProLiant 2014.42 (Recommended) Fixes Problems Fixed: The following issues are resolved with firmware version 5. P430. A controller lockup could occur if the controller was configured with a SmartCache smaller than 8GB. P830i. UEFI (Universal Extensible Firmware Interface). Improved RAID 1 performance for small block random write workloads on SSD configurations.0 Release Notes Online ROM Flash Component for Windows . In some cases. An issue which prevented the configuration of a maximum size HP SmartCache.0 . P721m. P420. P731m. SSD Over-provision Optimization (OPO). On some power cycles. An issue that prevented the spare drive Online LED from blinking if one data drive is failed during a RAID migration. P420i. Online ROM Flash Component for Windows . the supercap would always report that it was charging.06.42: o o o o o o Communication between the HP Integrated Lights-Out (iLO) and the HP Smart Array controller may be lost resulting in an IML entry indicating a failed controller. even though charging had completed.50 (Recommended) Fixes Problems Fixed: o o o o o o o An intermittent issue that can result in the system fans going to maximum speed during certain heavy IO loads. New 4GiB Controller cache module option. VMware might hang when a VM with 2 or more RDMs used a Smart Array controller to access an HP P2000 G3 or HP MSA 2040 SAN storage device. Loss of redundant paths following an update of HP D2600/D2700 firmware. P222. 16 or higher is required to enable dual domain functionality Fixes Firmware Dependency: o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.24(B).24 (B) (Recommended) Important Note! Customers who already installed firmware version 7. Additional rebuild priorities.24 do not need to update to 7. Updating the HP MSA 60 and/or MSA 70 firmware version to 2.16 or higher is required to enable dual domain functionality. the following enhancements were made: o o o Made changes to improve performance of low queue depth workloads.06. Added multi-drive RAID-0 sequential write performance enhancements. This would cause the component installation to end with a return code 3 (already up to date) and a force install would be required to successfully update the FW.24(B) .Fixed an issue where a decimal conversion was not being interpreted correctly when installing the component under certain regional settings in Windows. Problems Fixed: o o Resolved an issue where the server’s system event log would fill with Event ID 129 warnings and the Smart Array controller would become unresponsive.0 Release Notes o o 512e (Advanced Format) hard drives.06. Online ROM Flash Component for Windows .Smart Array P400 and P400i Version: 7.04 (B) (Recommended) Important Note! HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. Prerequisites   Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.Smart Array P600 Version: 2. FW version 7. Increased SAS phy error monitoring capabilities of the controller. Updating the HP MSA 60 and/or MSA 70 firmware version to 2. Online ROM Flash Component for Windows . Additionally.0 629 . Smart Array P700m Version: 7. Run Autorun from \_autorun\autorun_win.0 630 . Fixed an issue where Sequential reads on SATA drives in an HP StorageWorks MSA60 may lead to drive failures. another update is not needed.04(B) did not affect FW functionality. Online ROM Flash Component for Windows . Place the firmware to be updated in the directory.24 (B) (Recommended) Important Note! HP | Service Pack for ProLiant 2014.06.04. The changes for 2. Run Autorun from \_autorun\autorun_win. Enhancements Enhancements/New Features: o Updated the component flashing engine.exe on the Firmware Maintenance CD from the USB key on a system Select the Firmware Update tab Click on the Install Firmware link to launch the HP Smart Update Manager Follow the GUI to install the firmware on remote servers Fixes Important Notes: HP recommends for remote deployment of this package that you obtain the most recent version of the Firmware Maintenance CD and follow these steps: o o o o o o Place the Firmware Maintenance CD on a USB key using the USB Key Creator Utility.exe on the Firmware Maintenance CD from the USB key on a system Select the Firmware Update tab Click on the Install Firmware link to launch the HP Smart Update Manager Follow the GUI to install the firmware on remote servers Problems Fixed: o o Fixed an issue where incorrect data may be returned for a SCSI MODE SENSE command sent to a SATA drive. Place the firmware to be updated in the directory. HP recommends for remote deployment of this package that you obtain the most recent version of the Firmware Maintenance CD and follow these steps: o o o o o o Place the Firmware Maintenance CD on a USB key using the USB Key Creator Utility.06.HP Service Pack for ProLiant 2014.0 Release Notes If you have previously updated to version 2. /compaq/swpackages on the USB key. /compaq/swpackages on the USB key. HP Service Pack for ProLiant 2014.16 or higher is required to enable dual domain functionality.24(B) .0 Release Notes Customers who already installed firmware version 7. FW version 7.Fixed an issue where a decimal conversion was not being interpreted HP | Service Pack for ProLiant 2014. Updating the HP MSA 60 and/or MSA 70 firmware version to 2.24 do not need to update to 7. Prerequisites   Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.24(B) .06.Smart Array P800 Version: 7. Online ROM Flash Component for Windows . Updating the HP MSA 60 and/or MSA 70 firmware version to 2. Updating the HP MSA 60 and/or MSA 70 firmware version to 2. Fixes Firmware Dependency: o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs. Problems Fixed: o o Resolved an issue where the server’s system event log would fill with Event ID 129 warnings and the Smart Array controller would become unresponsive.24(B). This would cause the component installation to end with a return code 3 (already up to date) and a force install would be required to successfully update the FW. 631 Problems Fixed: o o Resolved an issue where the server’s system event log would fill with Event ID 129 warnings and the Smart Array controller would become unresponsive.16 or higher is required to enable dual domain functionality.24 (B) (Recommended) Important Note! Customers who already installed firmware version 7.06.24(B).16 or higher is required to enable dual domain functionality Fixes Firmware Dependency: o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.Fixed an issue where a decimal conversion was not being interpreted correctly when installing the component under certain regional settings in Windows.0 .24 do not need to update to 7. FW version 7. HP Service Pack for ProLiant 2014.HP Smart Array B320i RAID controller Version: 15. a cache module charging circuit failure would result in an incorrect POST 1705 error indicating the super-cap should be replaced.44: o Prior to version 0.HP 512MB Flash Backed Write Cache for B-Series Smart Array Version: 0. This would cause the component installation to end with a return code 3 (already up to date) and a force install would be required to successfully update the FW.86 (B) (Critical) HP | Service Pack for ProLiant 2014.00 (Recommended) Fixes Problems Fixed: The following issues are resolved in this version of the firmware: o Resolves the I/O errors and/or inability to access solid state drives (SSD) on systems using the HP Smart Array B320i RAID controller and certain SSDs. Customers who already installed firmware version 0. Supplemental Update / Online ROM Flash Component for Linux .44 do not need to update to 0. This firmware now detects cache module charging circuit failures and displays a new POST 1813 error that correctly instructs the user to replace the cache module.44.06. 632 Supplemental Update / Online ROM Flash Component for Linux .10.44 (B) (Optional) Important Note! o o Online firmware update available for systems running supported Linux and Microsoft Windows environments.06. Problems Fixed in version 0. All other OSes would require an offline update using the SPP and HP SUM.44 (B).Smart Array E200 and E200i Version: 1.44(B): o Resolved an issue where the Smart Component would hang during hardware discovery when an unknown device was present.0 Release Notes correctly when installing the component under certain regional settings in Windows.05. Fixes Problems Fixed in version 0.0 . Supplemental Update / Online ROM Flash Component for Linux . Enhancements Enhancements/New Features: o Added support for SUSE Linux Enterprise Server 11 SP2.24 (Recommended) Important Note! When running VMware ESX/ESXi. 1.0 Release Notes Prerequisites For optimal performance.4.HP Service Pack for ProLiant 2014. only offline updates are supported using the HP Smart Update Manager on the Firmware Maintenance CD.84.16 or higher is required to enable dual domain functionality Fixes Firmware Dependency: o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.06. Updating the HP MSA 60 and/or MSA 70 firmware version to 2. Fixes Problems Fixed: o Fixed an issue where logical drives were not being detected during POST or reboot on the HP Smart Array E200i controller with firmware version 1. Supplemental Update / Online ROM Flash Component for Linux .80.82 or 1. Prerequisites o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.06.0 633 .16 or higher is required to enable dual domain functionality. Updating the HP MSA 60 and/or MSA 70 firmware version to 2. driver version 2. Problems Fixed: HP | Service Pack for ProLiant 2014.48-12 or higher is strongly recommended with this firmware release.Smart Array E500 Version: 7. 0 .40 do not need to update to 6. On intermittent occasions. Customers could not invoke ORCA via command line interface. P711m.64 Fixes Problems Fixed in version 6.06. by pressing the escape keystrokes “Esc+6” or "F6" or “Esc+8” or "F8" via the BIOS Serial Console. Important Notes: o Reference Customer Advisory c03793656 .HP Service Pack for ProLiant 2014.0 Release Notes o Resolved an issue where the server’s system event log would fill with Event ID 129 warnings and the Smart Array controller would become unresponsive. P410. P410i. Problems Fixed in version 6. Note: Version 6. Enhancements Enhancements/New Features: o 634 Allow Windows Server 2012 drivers to utilize command addressing above the lower 4GB memory region when requested by the storage driver. but the following fixes are also provided in version 6. HP | Service Pack for ProLiant 2014. P411.40(B): o Fixed an installation issue where version 6.SYS Driver Version 62. which in turn disabled write caching.40 is no longer available for download from HP Support Center. Supplemental Update / Online ROM Flash Component for Linux . The POST was indicateding a bad Super-Cap.40: o o o o False POST 1705 messages were being posted on the HP BL465c G7 or HP BL685c G7 Blade systems that used HP Smart Array P410i controller firmware version 5.40 (B).HP ProLiant Server May Blue Screen if Configured With an HP Smart Array Controller and the Windows Server 2012 HPCISSS2.0. On rare occasions the controller would become unresponsive during POST.76 or greater. and P812 Version: 6.06.26. P712m.40(B).40 (B) (Recommended) Important Note! o Customers who already installed firmware version 6.Windows Server 2012 .40 of the Online Smart Array firmware smart components for the Smart Array P410i Controller would in some cases update the SAS expander in the HP D2200sb Storage Blade with incorrect firmware causing the Smart Array P410i Controller to be unable to communicate with the hard drives installed in the HP D2200sb Storage Blade. SATA spare drives in a JBOD were being marked as hot removed and then rediscovered.Smart Array P212. Reference Customer Advisory c03964262 for additional important information about this issue. VMware might hang when a VM with 2 or more RDMs used a Smart Array controller to access an HP P2000 G3 or HP MSA 2040 SAN storage device.42 (Recommended) Fixes Problems Fixed: The following issues are resolved with firmware version 5.0 . On some power cycles.Smart Array P230i. An issue that could lead to the controller’s read/write cache being disabled in certain scenarios. the supercap would always report that it was charging. P420.06. P421. P721m. resulting in a system shutdown.HP Service Pack for ProLiant 2014. Supplemental Update / Online ROM Flash Component for Linux . P222. New 4GiB Controller cache module option. The logging of an invalid Smart Array controller failure following a kdump or kexec. and P830 Version: 1. even though charging had completed. Enhancements Enhancements/New Features: 635 Added support for following new features: o o HP Secure Encryption. P731m. In some cases. A controller lockup could occur if the controller was configured with a SmartCache smaller than 8GB. P430. incorrect drive temperatures were reported in an HP D2220sb enclosure. An issue that prevented the spare drive Online LED from blinking if one data drive is failed during a RAID migration. and P822 Version: 5. Improved RAID 1 performance for small block random write workloads on SSD configurations.Smart Array P220i. HP | Service Pack for ProLiant 2014. P431. Loss of redundant paths following an update of HP D2600/D2700 firmware. P830i.0 Release Notes Supplemental Update / Online ROM Flash Component for Linux . P420i.42: o o o o o o Communication between the HP Integrated Lights-Out (iLO) and the HP Smart Array controller may be lost resulting in an IML entry indicating a failed controller.50 (Recommended) Fixes Problems Fixed: o o o o o o o An intermittent issue that can result in the system fans going to maximum speed during certain heavy IO loads. An issue that prevented HP SSD SmartPath from being enabled in certain scenarios.06. An issue which prevented the configuration of a maximum size HP SmartCache. Prerequisites o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs. Additional rebuild priorities. Problems Fixed: o Resolved an issue where the server’s system event log would fill with Event ID 129 warnings and the Smart Array controller would become unresponsive. Increased SAS phy error monitoring capabilities of the controller.24 (Recommended) Important Note! When running VMware ESX/ESXi.16 or higher is required to enable dual domain functionality Fixes Firmware Dependency: o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs. only offline updates are supported using the HP Smart Update Manager on the Firmware Maintenance CD. the following enhancements were made: o o o Made changes to improve performance of low queue depth workloads. 512e (Advanced Format) hard drives.0 Release Notes o o o o UEFI (Universal Extensible Firmware Interface). Added multi-drive RAID-0 sequential write performance enhancements.Smart Array P400 and P400i Version: 7.16 or higher is required to enable dual domain functionality.06. 636 HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014. Additionally. Updating the HP MSA 60 and/or MSA 70 firmware version to 2. Updating the HP MSA 60 and/or MSA 70 firmware version to 2.0 . Supplemental Update / Online ROM Flash Component for Linux .06. SSD Over-provision Optimization (OPO). 0 Release Notes Supplemental Update / Online ROM Flash Component for Linux . only offline updates are supported using the HP Smart Update Manager on the Firmware Maintenance CD.16 or higher is required to enable dual domain functionality Fixes Firmware Dependency: o 637 Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.0 .Smart Array P700m Version: 7. HP | Service Pack for ProLiant 2014.24 (Recommended) Important Note! When running VMware ESX/ESXi. Supplemental Update / Online ROM Flash Component for Linux . Problems Fixed: o Resolved an issue where the server’s system event log would fill with Event ID 129 warnings and the Smart Array controller would become unresponsive. Updating the HP MSA 60 and/or MSA 70 firmware version to 2. Updating the HP MSA 60 and/or MSA 70 firmware version to 2.HP Service Pack for ProLiant 2014. Prerequisites o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.24 (Recommended) Important Note! When running VMware ESX/ESXi. Fixes Firmware Dependency: o o Updating the HP DL360G5 System ROM to revision P58 3/9/08 or higher is required in addition to updating to this HP Smart Array firmware revision for the modified shutdown sequence to ensure sufficient time for HDD head parking of internal HDDs.16 or higher is required to enable dual domain functionality.06.06. only offline updates are supported using the HP Smart Update Manager on the Firmware Maintenance CD.Smart Array P800 Version: 7. Resolves SAS link errors that may occur with cascaded HP D6000 disk enclosures (limited support for cascading). Supplemental Update / Online ROM Flash Component for Linux – HP D6000 Disk Enclosure Version: 2.06. Resolves a Smart Array controller 0xAB lockup observed during SAS switch reboots in HP BladeSystem configurations.06. Supplemental Update / Online ROM Flash Component for Linux – HP Gen8 Server Backplane Expander Firmware for HP Smart Array Controllers and HP HBA Controllers Version: 3. VMware ESXi.30 (Recommended) Important Note! o Online backplane expander firmware update available for Smart Array Controllers configured in systems running supported Linux. Fixes Problems Fixed: o o Fixed an issue with the SAS connector element which reported invalid connector type/physical link for disabled PHYs.0 638 . and Microsoft Windows environments. SAS drive link rates are still 6G. HP | Service Pack for ProLiant 2014.0 Release Notes o Updating the HP MSA 60 and/or MSA 70 firmware version to 2. All other OSes would require an offline update using the SPP and HP SUM.HP Service Pack for ProLiant 2014. Limits the SATA drive link rate to 3G. Problems Fixed: o Resolved an issue where the server’s system event log would fill with Event ID 129 warnings and the Smart Array controller would become unresponsive. Fixed the Logical Link Rate because the Rate was not set properly when PHY is disabled.54 (Recommended) Fixes Problems Fixed: o o o o Improved signal integrity settings to reduce the occurrence of PHY DWORD errors when using HP D6000 Disk Enclosures.16 or higher is required to enable dual domain functionality. hp.Storage Fibre Channel HP Firmware Flash for Brocade Fibre Channel Host Bus Adapters . version 3.2.HP Service Pack for ProLiant 2014. HP-FC-Brocade-Enablement-Kit-2. Enhancements Boot bios updated to version 3. The driver and enablement kit are also available on the HP Service Pack for Proliant (SPP) version 2013.2.i386.rpm Note that the driver must be installed before the enablement kit. Select your product and then select the Software and Drivers page to find the required driver and enablement kit.06.2.1.0.01 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes 639 Prerequisites The HP supplied Brocade driver and enablement kit must be installed prior to this firmware component being identified by HP SUM for deployment.Linux (x86_64) Version: 2013.0 Release Notes Top Firmware . Supported Devices and Features This firmware supports the following HP adapters: o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Firmware Flash for Brocade Fibre Channel Host Bus Adapters . The software is available from www.01 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes Prerequisites The HP supplied Brocade driver and enablement kit must be installed prior to this firmware component being identified by HP SUM for deployment.0 driver.0 which is available at www.09.Linux (x86) Version: 2013.1.0 to synchronize with HP's Brocade 3. The software is available HP | Service Pack for ProLiant 2014.08.0 .hp.08.0-1.1.06.com/go/spp/download.com/go/fchba.0.0 HP Fibre Channel Enablement Kit for Linux. o o Linux FC Driver Kit for HP Brocade HBAs and mezzanine HBAs. 01 (Optional) HP | Service Pack for ProLiant 2014. HP-FC-Brocade-Enablement-Kit-2. The driver and enablement kit are also available on the HP Service Pack for Proliant (SPP) version 2013.1.04.0-1.2. o o Linux FC Driver Kit for HP Brocade HBAs and mezzanine HBAs. Enhancements Boot bios updated to version 3.0 Release Notes from www.09.HP Service Pack for ProLiant 2014.0 to synchronize with HP's Brocade 3.1.0 which is available at www.x86_64.com/go/spp/download.0 driver.0 Supported Devices and Features This firmware supports the following HP adapters: o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Firmware Flash for Emulex Fibre Channel Host Bus and Converged Network Adapters . 3.2.2.1. version 3.06.Linux (x86) Version: 2014.com/go/fchba.hp.rpm Note that the driver must be installed before the enablement kit.VMWare Version: 2013.0 HP Fibre Channel Enablement Kit for Linux. Supported Devices and Features This firmware supports the following HP adapters: o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Firmware Flash for Brocade Fibre Channel Host Bus Adapters .0.08. Contains boot bios version.hp.06.01 (Recommended) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes Enhancements Initial version.0 640 .2. Select your product and then select the Software and Drivers page to find the required driver and enablement kit.1.0. 7.0 Release Notes Important Note! Release Notes: HP StorageWorks Emulex Adapters Release Notes Prerequisites Note: This component will flash the CN1000E and NC550SFP products only if the minimum firmware version. The software is available from www. Select your product and then select the Software and Drivers page to find the required driver and enablement kit. version 8. The drivers are also available on the HP Service Pack for Proliant (SPP) version 2014.0 which is available at www. o HP Emulex 10Gbe Driver for Linux.3.com/go/spp/download.1. which is available at www. is installed.311.360.06.10a15 (3.0 .33.so) installed for component to be able to discover Emulex HBAs/CNAs.HP Service Pack for ProLiant 2014.6.com/go/fchba and www.1. o HP Fibre Channel Enablement Kit for Linux.101 HP | Service Pack for ProLiant 2014.15. for RedHat 6 and Novell SUSE 11 Linux FC Driver Kit for HP Branded Emulex FC HBAs and mezz cards. o o Linux FC Driver Kit for HP Branded Emulex FC HBAs and mezz cards.9.com/go/cna. version 4.hp.06.1 Environment must be running the syslog daemon for the flash engine to run.hp. 4. HP-CNA-FC-Emulex_Enablement-Kit.com/go/spp/download.1.2 Note that the driver must be installed before the enablement kit.com at the link above.2.02.65. Use the appropriate driver included in the HP Support Pack for ProLiant 2014.21. version 6.02. Fixes Boot Image (BIOS) 8Gb Mezzanine . The HP supplied Emulex driver and enablement kit must be installed prior to this firmware component being identified by HP SUM for deployment. for RedHat 5 The updated enablement kit is available on hp.30a2 BIOS) o LPe1205 virtual WWN's still used after changing to default mode in VC-FC 641 Firmware 16Gb Standup & Mezzanine .hp. Environment must have 32-bit netlink library (libnl.hp.4. version 8.0.39. The HP supplied NIC driver must be installed prior to this firmware component if you want to update the firmware for the CNA.2. 101 8 Gb Gen8 Mezz (LPe1205A) firmware 2.0 o Added support for VC 4.13a8 UEFI) 8 Gb Mezz boot image 6.101 o o Point to Point configuration Performance Enhancement Added support for UEFI/Legacy BIOS boot CNA .5.12a14 BIOS 4.0 642 . SAN path failures occur after 511 days of uptime.02.10a14 (3.9.4.1.20x7 (2.30a1 BIOS) HP | Service Pack for ProLiant 2014.416.12a14 BIOS.65.0 Updated 16Gb firmware version to 1. (required to support windows driver in SPP 2014.13a8 UEFI) o Added UEFI support for 8Gb HBAs 82E & 81E Firmware 16Gb Standup & Mezzanine .9.0 16 Gb HBA/Mezz universal boot 1.1.20x7 (signed UEFI) Boot Image (BIOS) 8Gb Standup .9.416.06.0 o o o o o o Allow for use of iSCSI option during boot & BIOS on NC551i LOM. Added a routine to program the HW to clear the TX flow control on Port0 & Port1 to stop the pause frames from continuing on UE. Modified firmware to support Hyper-V changes in driver.HP Service Pack for ProLiant 2014.01a12 8 Gb HBA boot image 5.9. 4.1.65.65.4.416.416.30a2 BIOS) 4 Gb HBA/Mezz firmware 2.101 Updated 8Gb Standup Boot image version to 5.20.06.82x4 4 Gb Mezz boot image 6.02X6 8 Gb HBA/Mezz firmware 2. NC551i stops passing traffic when promiscuous mode is flipped on then off.10a15 (3. Pause frame issue caused when additional RSS queues created and do not generate interrupts.1.20x7 (2. Contains: CNA firmware 4. Enhancements Updated CNA firmware version to 4.0 Release Notes o Restrict Boot Menu from selecting 2g or 4g link speeds CNA .0). 1.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2. The HP supplied Emulex driver and enablement kit must be installed prior to this firmware component HP | Service Pack for ProLiant 2014.0 Release Notes 4 Gb HBA boot image 5.15.06.01 (Optional) Important Note! Release Notes: HP StorageWorks Emulex Adapters Release Notes Prerequisites Note: This component will flash the CN1000E and NC550SFP products only if the minimum firmware version. is installed.04.06.20a6 (2. 4.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz HP Firmware Flash for Emulex Fibre Channel Host Bus and Converged Network Adapters .Linux (x86_64) Version: 2014.12a14 BIOS) Supported Devices and Features o o o o o o o o o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.HP Service Pack for ProLiant 2014.360.0 643 . 10a15 (3.2 Note that the driver must be installed before the enablement kit.30a2 BIOS) o LPe1205 virtual WWN's still used after changing to default mode in VC-FC Firmware 16Gb Standup & Mezzanine . o o Linux FC Driver Kit for HP Branded Emulex FC HBAs and mezz cards.65. Fixes Boot Image (BIOS) 8Gb Mezzanine .02.3. SAN path failures occur after 511 days of uptime.9. for RedHat 5 The updated enablement kit is available on hp. The HP supplied NIC driver must be installed prior to this firmware component if you want to update the firmware for the CNA. Added a routine to program the HW to clear the TX flow control on Port0 & Port1 to stop the pause frames from continuing on UE. HP-CNA-FC-Emulex_Enablement-Kit.0). (required to support windows driver in SPP 2014.06.4. Environment must have 32-bit netlink library (libnl.0 644 .HP Service Pack for ProLiant 2014. Select your product and then select the Software and Drivers page to find the required driver and enablement kit.com at the link above.02.0. o HP Emulex 10Gbe Driver for Linux.so) installed for component to be able to discover Emulex HBAs/CNAs.06. which is available at www. for RedHat 6 and Novell SUSE 11 Linux FC Driver Kit for HP Branded Emulex FC HBAs and mezz cards.com/go/cna. The drivers are also available on the HP Service Pack for Proliant (SPP) version 2014.39.hp.4. version 6.7.2. NC551i stops passing traffic when promiscuous mode is flipped on then off.1. The software is available from www.0 Release Notes being identified by HP SUM for deployment.com/go/spp/download.311.21.2.416.0 o o o o o Allow for use of iSCSI option during boot & BIOS on NC551i LOM.9.com/go/spp/download.101 o Restrict Boot Menu from selecting 2g or 4g link speeds CNA .hp. Use the appropriate driver included in the HP Support Pack for ProLiant 2014. HP | Service Pack for ProLiant 2014. version 8.hp.hp.1 Environment must be running the syslog daemon for the flash engine to run. Modified firmware to support Hyper-V changes in driver.1.33.02.com/go/fchba and www.0 which is available at www.6. version 8. o HP Fibre Channel Enablement Kit for Linux. version 4. 30a1 BIOS) 4 Gb HBA boot image 5.30a2 BIOS) 4 Gb HBA/Mezz firmware 2. 4. Enhancements Updated CNA firmware version to 4.01a12 8 Gb HBA boot image 5.0 o Added support for VC 4.0 645 .20a6 (2.06.12a14 BIOS.4.101 Updated 8Gb Standup Boot image version to 5. Contains: CNA firmware 4.20x7 (signed UEFI) Boot Image (BIOS) 8Gb Standup .10a14 (3.12a14 BIOS 4.1.HP Service Pack for ProLiant 2014.65.9.13a8 UEFI) 8 Gb Mezz boot image 6.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP | Service Pack for ProLiant 2014.1.1.0 Updated 16Gb firmware version to 1.20x7 (2.0 16 Gb HBA/Mezz universal boot 1.416.5.9.1.9.101 8 Gb Gen8 Mezz (LPe1205A) firmware 2.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.416.20.65.82x4 4 Gb Mezz boot image 6.65.20x7 (2.416.10a15 (3.02X6 8 Gb HBA/Mezz firmware 2.13a8 UEFI) o Added UEFI support for 8Gb HBAs 82E & 81E Firmware 16Gb Standup & Mezzanine .12a14 BIOS) Supported Devices and Features o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.101 o o Point to Point configuration Performance Enhancement Added support for UEFI/Legacy BIOS boot CNA .06.0 Release Notes o Pause frame issue caused when additional RSS queues created and do not generate interrupts. 101 o Restrict Boot Menu from selecting 2g or 4g link speeds 646 CNA .06.1.04.0 .HP Service Pack for ProLiant 2014.1.0 o o Allow for use of iSCSI option during boot & BIOS on NC551i LOM.9.0 Release Notes o o o o o o o o o o o o o o o o o o o o o o HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz HP Firmware Flash for Emulex Fibre Channel Host Bus and Converged Network Adapters .6.1 Version: 2014.30a2 BIOS) o LPe1205 virtual WWN's still used after changing to default mode in VC-FC Firmware 16Gb Standup & Mezzanine .VMware 5.06. Added a routine to program the HW to clear the TX flow control on Port0 & Port1 to stop the HP | Service Pack for ProLiant 2014.01 (Optional) Important Note! Release Notes: HP StorageWorks Emulex Adapters Release Notes Fixes Boot Image (BIOS) 8Gb Mezzanine .65.4.416.0/5.10a15 (3. NC551i stops passing traffic when promiscuous mode is flipped on then off. Contains: CNA firmware 4.01a12 8 Gb HBA boot image 5.HP Service Pack for ProLiant 2014.101 Updated 8Gb Standup Boot image version to 5.12a14 BIOS) 647 Supported Devices and Features o HP StorageWorks FC2243 4 Gb PCI-X 2.4.9.0 Updated 16Gb firmware version to 1.20a6 (2.12a14 BIOS.0 DC HBA HP | Service Pack for ProLiant 2014.30a2 BIOS) 4 Gb HBA/Mezz firmware 2.65.416.13a8 UEFI) o Added UEFI support for 8Gb HBAs 82E & 81E Firmware 16Gb Standup & Mezzanine .0 Release Notes o o o o pause frames from continuing on UE.20.10a14 (3.1.5.02X6 8 Gb HBA/Mezz firmware 2. Pause frame issue caused when additional RSS queues created and do not generate interrupts.1.416.10a15 (3.1.9.06.0 . SAN path failures occur after 511 days of uptime.0 o Added support for VC 4.20x7 (signed UEFI) Boot Image (BIOS) 8Gb Standup .20x7 (2.416.06.0).12a14 BIOS 4.0 16 Gb HBA/Mezz universal boot 1.9. (required to support windows driver in SPP 2014.30a1 BIOS) 4 Gb HBA boot image 5.1.101 8 Gb Gen8 Mezz (LPe1205A) firmware 2.20x7 (2.02.65.101 o o Point to Point configuration Performance Enhancement Added support for UEFI/Legacy BIOS boot CNA .65. Enhancements Updated CNA firmware version to 4.82x4 4 Gb Mezz boot image 6.13a8 UEFI) 8 Gb Mezz boot image 6. Modified firmware to support Hyper-V changes in driver. 4. 5 Version: 2014.1.0 Release Notes o o o o o o o o o o o o o o o o o o o o o o o o o o o HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.1.10a15 (3.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz HP Firmware Flash for Emulex Fibre Channel Host Bus and Converged Network Adapters for VMware vSphere 5.06.0 .01 (Optional) Important Note! Release Notes: HP StorageWorks Emulex Adapters Release Notes Fixes Boot Image (BIOS) 8Gb Mezzanine .30a2 BIOS) o LPe1205 virtual WWN's still used after changing to default mode in VC-FC 648 Firmware 16Gb Standup & Mezzanine .06.HP Service Pack for ProLiant 2014.04.101 HP | Service Pack for ProLiant 2014.6.65. 0 o o o o o o Allow for use of iSCSI option during boot & BIOS on NC551i LOM.30a2 BIOS) 4 Gb HBA/Mezz firmware 2.1.4.1.20x7 (2. NC551i stops passing traffic when promiscuous mode is flipped on then off.416.65.10a14 (3. SAN path failures occur after 511 days of uptime. 4.0 16 Gb HBA/Mezz universal boot 1. Contains: CNA firmware 4. (required to support windows driver in SPP 2014. Added a routine to program the HW to clear the TX flow control on Port0 & Port1 to stop the pause frames from continuing on UE.101 o o Point to Point configuration Performance Enhancement Added support for UEFI/Legacy BIOS boot CNA .0 o Added support for VC 4.416.02X6 8 Gb HBA/Mezz firmware 2.82x4 4 Gb Mezz boot image 6.0 649 .9.416.13a8 UEFI) 8 Gb Mezz boot image 6.0).06.65.13a8 UEFI) o Added UEFI support for 8Gb HBAs 82E & 81E Firmware 16Gb Standup & Mezzanine .02.9.65.416.20x7 (2.5.20. Enhancements Updated CNA firmware version to 4.10a15 (3.1.0 Release Notes o Restrict Boot Menu from selecting 2g or 4g link speeds CNA .01a12 8 Gb HBA boot image 5.20x7 (signed UEFI) Boot Image (BIOS) 8Gb Standup .12a14 BIOS.30a1 BIOS) HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.12a14 BIOS 4. Pause frame issue caused when additional RSS queues created and do not generate interrupts.06.0 Updated 16Gb firmware version to 1.4.9.9. Modified firmware to support Hyper-V changes in driver.1.101 8 Gb Gen8 Mezz (LPe1205A) firmware 2.101 Updated 8Gb Standup Boot image version to 5. 04.04.01 (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes Prerequisites The HP supplied QLogic driver and enablement kit must be installed prior to this firmware component being identified by HP SUM for deployment.12.Linux (x86) Version: 2014.06.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.6- HP | Service Pack for ProLiant 2014.06.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz HP Firmware Flash for QLogic Fibre Channel Host Bus Adapters .5.00.12a14 BIOS) Supported Devices and Features o o o o o o o o o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.0 650 .0 Release Notes 4 Gb HBA boot image 5.HP Service Pack for ProLiant 2014.com/go/fchba. o Linux FCoE/FC Driver Kit for HP Qlogic CNAs.hp. The software is available from www.20a6 (2. HBAs and mezzanine HBAs version 8. for Red Hat 5 o Linux FCoE/FC Driver Kit for HP Qlogic CNAs.0-4.59AF  Firmware 5.0.03.12.00.09.06.13 UEFI 6.3k4.13 o 8 Gb HBA/Mezz  Enabled legacy BIOS boot  Enabled secure boot     o Package 3.06.15  BIOS 3.04.13 o QMH2572 Mezz Card  Package 2.03AF  Firmware 5. HBAs and mezzanine HBAs version 8. for Novell SUSE 11 o HP Fibre Channel Enablement Kit for Linux version 2.06.28 651 16 Gb HBA/Mezz  Enabled legacy BIOS boot HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.0 Release Notes k2. o 4 Gb HBA/Mezz  Package 2.11.04  BIOS 3.0.60A4 Firmware 5. for QLogic Enhancements o Updated the firmware/BIOS packages for 8 Gb and 16 Gb products.00 BIOS 3.0 . HP Service Pack for ProLiant 2014.06.com/go/fchba.0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP StoreFabric SN1000Q 16Gb PCIe Fibre Channel Host Bus Adapter HP QMH2672 16Gb FC HBA for c-Class BladeSystem HP Firmware Flash for QLogic Fibre Channel Host Bus Adapters .06.12.21 UEFI 6.07.6k2. HBAs and mezzanine HBAs version 8. o Linux FCoE/FC Driver Kit for HP Qlogic CNAs. for Red Hat 5 652 o Linux FCoE/FC Driver Kit for HP Qlogic CNAs. HBAs and mezzanine HBAs version 8.hp.Linux (x86_64) Version: 2014.0 HBA HP StorageWorks FC1243 4Gb PCI-X 2.04.90. for Red Hat 6 HP | Service Pack for ProLiant 2014.0 .0 Release Notes  Enabled secure boot     Package 3.00.00.04.12.02 Firmware 6.0k4.01 (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes Prerequisites The HP supplied QLogic driver and enablement kit must be installed prior to this firmware component being identified by HP SUM for deployment.5.06. The software is available from www.25 Supported Devices and Features This firmware supports the following HP adapters: o o o o o o o o o o o HP StorageWorks FC1143 4Gb PCI-X 2.02 BIOS 3.04. 06.0.60A4 Firmware 5.09.3k4.00.04  BIOS 3.04.13 UEFI 6.21 UEFI 6. HBAs and mezzanine HBAs version 8. for Novell SUSE 11 o HP Fibre Channel Enablement Kit for Linux version 2.13 o 8 Gb HBA/Mezz  Enabled legacy BIOS boot  Enabled secure boot     o Package 3.06.25 653 HP | Service Pack for ProLiant 2014.0 Release Notes o Linux FCoE/FC Driver Kit for HP Qlogic CNAs.59AF  Firmware 5.07.11.0-4.0.15  BIOS 3.12.02 BIOS 3. o 4 Gb HBA/Mezz  Package 2.90.00 BIOS 3.03.13 o QMH2572 Mezz Card  Package 2.03AF  Firmware 5.06. for QLogic Enhancements o Updated the firmware/BIOS packages for 8 Gb and 16 Gb products.0 .28 16 Gb HBA/Mezz  Enabled legacy BIOS boot  Enabled secure boot     Package 3.02 Firmware 6.HP Service Pack for ProLiant 2014. 15  BIOS 3.03.09.13 UEFI 6.13 o 8 Gb HBA/Mezz  Enabled legacy BIOS boot  Enabled secure boot     o Package 3.03AF  Firmware 5.VMware Version: 2014.04  BIOS 3.28 654 16 Gb HBA/Mezz  Enabled legacy BIOS boot  Enabled secure boot HP | Service Pack for ProLiant 2014.0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP StoreFabric SN1000Q 16Gb Fibre Channel Host Bus Adapter HP QMH2672 16Gb FC HBA for c-Class BladeSystem HP Firmware Flash for QLogic Fibre Channel Host Bus Adapters .0 Release Notes Supported Devices and Features This firmware supports the following HP adapters: o o o o o o o o o o o HP StorageWorks FC1143 4Gb PCI-X 2.60A4 Firmware 5.00 BIOS 3.0 HBA HP StorageWorks FC1243 4Gb PCI-X 2. o 4 Gb HBA/Mezz  Package 2.04.06.HP Service Pack for ProLiant 2014.06.01 (Optional) Enhancements Updated the firmware/BIOS packages for 8 Gb and 16 Gb products.13 o QMH2572 Mezz Card  Package 2.59AF  Firmware 5.0 .06. 06.03AF  Firmware 5.15  BIOS 3.HP Service Pack for ProLiant 2014.21 UEFI 6.5 Version: 2014.0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP StoreFabric SN1000Q 16Gb Fibre Channel Host Bus Adapter HP QMH2672 16Gb FC HBA for c-Class BladeSystem HP Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 5.01 (Optional) Enhancements o Updated the firmware/BIOS packages for 8 Gb and 16 Gb products.06.25 Supported Devices and Features This firmware supports the following HP adapters: o o o o o o o o o o o HP StorageWorks FC1143 4Gb PCI-X 2.59AF  Firmware 5.02 Firmware 6.03.0 Release Notes     Package 3.0 HBA HP StorageWorks FC1243 4Gb PCI-X 2.04  BIOS 3.0 .07.13 o QMH2572 Mezz Card  Package 2.90. o 4 Gb HBA/Mezz  Package 2.04.13 o 8 Gb HBA/Mezz  Enabled legacy BIOS boot  Enabled secure boot 655 HP | Service Pack for ProLiant 2014.06.02 BIOS 3. 0 HBA HP StorageWorks FC1243 4Gb PCI-X 2.0 Release Notes     o Package 3. The HP Brocade driver is also available on the HP Service Pack for Proliant (SPP) version 2013.21 UEFI 6.com/go/fchba.01 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes Prerequisites The HP supplied Brocade driver must be installed prior to this firmware component being identified by HP SUM for deployment.0 which is available HP | Service Pack for ProLiant 2014.09.02 BIOS 3.09.25 Supported Devices and Features This firmware supports the following HP adapters: o o o o o o o o o o o HP StorageWorks FC1143 4Gb PCI-X 2.hp.07. Select your product and then select the Software and Drivers page to find the required driver.HP Service Pack for ProLiant 2014.06.90.0 656 .00 BIOS 3. The software is available from www.28 16 Gb HBA/Mezz  Enabled legacy BIOS boot  Enabled secure boot     Package 3.08.06.02 Firmware 6.13 UEFI 6.0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP StoreFabric SN1000Q 16Gb Fibre Channel Host Bus Adapter HP QMH2672 16Gb FC HBA for c-Class BladeSystem HP Firmware Online Flash for Brocade Fibre Channel Host Bus Adapters Windows 2008 (x86) Version: 2013.60A4 Firmware 5. 1.06.01 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes Prerequisites The HP supplied Brocade driver must be installed prior to this firmware component being identified by HP SUM for deployment.exe Enhancements Boot bios updated to version 3.09. cp019327. cp019318.0 to synchronize with HP's Brocade 3.hp.0 .exe HP Storage x64 Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2012. cp019319.2.0. The HP Brocade driver is also available on the HP Service Pack for Proliant (SPP) version 2013.0 Release Notes at www.2.hp.0 driver.2.1.2.08.1.1.com/go/fchba.0 to synchronize with HP's Brocade 3. Supported Devices and Features This firmware supports the following HP adapters: o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Firmware Online Flash for Brocade Fibre Channel Host Bus Adapters Windows 2008/2012 (x64) Version: 2013. o o o HP Storage x64 Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2008.0 which is available at www.1.2.0. o HP Storage x86 Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2008.0. version 3.exe HP Storage x64 Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2008 R2.0.0 driver. Select your product and then select the Software and Drivers page to find the required driver. version 3. Supported Devices and Features This firmware supports the following HP adapters: o o 657 HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP | Service Pack for ProLiant 2014.hp.2. version 3. version 3.1. The software is available from www.exe Enhancements Boot bios updated to version 3.1.com/go/spp/download.2.2.1.com/go/spp/download.06.HP Service Pack for ProLiant 2014. cp019320. version 3.06. o HP Storage x64 Brocade Storport Fibre Channel Host Bus Adapter Driver for Microsoft Windows Server 2012 R2.exe Enhancements Initial version to support Microsoft Windows Server 2012 R2 Supported Devices and Features This firmware supports the following HP adapters: o o o o o HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Firmware Online Flash for Emulex Fibre Channel Host Bus and Converged Network Adapters .01 (Optional) Important Note! Release Notes: HP StorageWorks Brocade Fibre Channel Host Bus Adapters Release Notes Prerequisites The HP supplied Brocade driver must be installed prior to this firmware component being identified by HP SUM for deployment.3.11.0 . cp021773.1.hp.aspx?docname=4AA47658ENW&cc=us&lc=en.2.04. Information about obtaining the HP-supplied drivers for Windows Server 2012 R2 is found in the technical white paper “Implementing Microsoft Windows Server 2012 R2 on HP ProLiant servers” available at http://h20195.com/V2/GetDocument.HP Service Pack for ProLiant 2014.www2.01 (Optional) Important Note! Release Notes: HP StorageWorks Emulex Adapters Release Notes 658 Prerequisites The HP supplied Emulex driver must be installed prior to this firmware component being identified by HP HP | Service Pack for ProLiant 2014.Windows 2008 x86 Version: 2014.06.0 Release Notes o o o HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter Brocade 804 8Gb Fibre Channel HBA for c-Class BladeSystem HP Firmware Online Flash for Brocade Fibre Channel Host Bus Adapters Windows Server 2012 R2 (x64) Version: 2013. hp.9.06.0 Updated 16Gb firmware version to 1. Use the appropriate driver included in the HP Support Pack for ProLiant 2014.1109 cp020992.1.10a15 (3.3.101 o Restrict Boot Menu from selecting 2g or 4g link speeds CNA .101 Updated 8Gb Standup Boot image version to 5.hp.6.20x7 (signed UEFI) 659 Boot Image (BIOS) 8Gb Standup .13a8 UEFI) HP | Service Pack for ProLiant 2014.com/go/spp/download: o HP Emulex 10GbE Driver for Windows Server 2008 x86 Editions v10.02.3.exe Fixes Boot Image (BIOS) 8Gb Mezzanine .06. Enhancements Updated CNA firmware version to 4.0 o o o o o o Allow for use of iSCSI option during boot & BIOS on NC551i LOM. SAN path failures occur after 511 days of uptime.1 cp021141.0.02. Pause frame issue caused when additional RSS queues created and do not generate interrupts.com/go/spp/download: o o HP Storage Fibre Channel Adapter Kit for the x86 Emulex Storport Driver v2. which is available at www.0.4.exe HP Storage Fibre Channel Over Ethernet Adapter Kit for the x86 Emulex Storport Driver v2.76.430. Use the appropriate driver included in the HP Support Pack for ProLiant 2014.20x7 (2.HP Service Pack for ProLiant 2014.9.1. Added a routine to program the HW to clear the TX flow control on Port0 & Port1 to stop the pause frames from continuing on UE. which is available at www.0.416.exe The HP supplied Emulex NIC driver must be installed prior to this firmware component being identified by HP SUM for deployment.0).1.12a14 BIOS 4.76. NC551i stops passing traffic when promiscuous mode is flipped on then off.416.65. (required to support windows driver in SPP 2014.02.5.30a2 BIOS) o LPe1205 virtual WWN's still used after changing to default mode in VC-FC Firmware 16Gb Standup & Mezzanine .0 .0 Release Notes SUM for deployment.1 cp021139. Modified firmware to support Hyper-V changes in driver.65. 101 8 Gb Gen8 Mezz (LPe1205A) firmware 2. Contains: CNA firmware 4.10a14 (3.12a14 BIOS) Supported Devices and Features o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.10a15 (3.30a2 BIOS) 4 Gb HBA/Mezz firmware 2.01a12 8 Gb HBA boot image 5.13a8 UEFI) 8 Gb Mezz boot image 6.101 o o Point to Point configuration Performance Enhancement Added support for UEFI/Legacy BIOS boot CNA .1.65.4.12a14 BIOS.0 Release Notes o Added UEFI support for 8Gb HBAs 82E & 81E Firmware 16Gb Standup & Mezzanine .416.HP Service Pack for ProLiant 2014.65.0 660 .02X6 8 Gb HBA/Mezz firmware 2.1.416.0 16 Gb HBA/Mezz universal boot 1.20.1.20x7 (2.82x4 4 Gb Mezz boot image 6.06.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.9.06. 4.20a6 (2.0 o Added support for VC 4.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP | Service Pack for ProLiant 2014.30a1 BIOS) 4 Gb HBA boot image 5.9. 3.exe HP Emulex 10Gbe Driver for Windows Server 2012 R2 v10.exe Fixes Boot Image (BIOS) 661 8Gb Mezzanine .76.02.1 cp020896.1109 cp020993.exe The HP supplied Emulex NIC driver must be installed prior to this firmware component being identified by HP SUM for deployment. which is available at www.1109 cp020995.3.0 Release Notes o o o o o o o o HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz HP Firmware Online Flash for Emulex Fibre Channel Host Bus and Converged Network Adapters .hp.04.com/go/spp/download: o o o o HP Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver v2.01 (Optional) Important Note! Release Notes: HP StorageWorks Emulex Adapters Release Notes Prerequisites The HP supplied Emulex driver must be installed prior to this firmware component being identified by HP SUM for deployment.0.HP Service Pack for ProLiant 2014.Windows 2008/2012/2012 R2 x64 Version: 2014.1 cp021138.0.76.1109 cp022157.06.com/go/spp/download: o o o o HP Emulex 10GbE Driver for Windows Server 2008 x64 Editions v10.0.06.430.exe HP Emulex 10Gbe Driver for Windows Server 2012 v10. Use the appropriate driver included in the HP Support Pack for ProLiant 2014.0. which is available at www.10a15 (3.76.30a2 BIOS) o LPe1205 virtual WWN's still used after changing to default mode in VC-FC HP | Service Pack for ProLiant 2014.1 cp021140.0 .exe HP Storage Fibre Channel Adapter Kit for the Emulex Storport Driver for Windows Server 2012 and 2012 R2 v2.exe HP Emulex 10GbE Driver for Windows Server 2008 R2 v10.430.0. Use the appropriate driver included in the HP Support Pack for ProLiant 2014.1 cp020897.430.02.1109 cp020994.430.3.hp.6.76.0.3.exe HP Storage Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver v2.exe HP Storage Fibre Channel Over Ethernet Adapter Kit for the Emulex Storport Driver for Windows Server 2012 and 2012 R2 v2. 1. Added a routine to program the HW to clear the TX flow control on Port0 & Port1 to stop the pause frames from continuing on UE.416.02.0 Updated 16Gb firmware version to 1. Modified firmware to support Hyper-V changes in driver.02X6 8 Gb HBA/Mezz firmware 2.9. 4.101 o Restrict Boot Menu from selecting 2g or 4g link speeds CNA .0 . SAN path failures occur after 511 days of uptime.416. Contains: CNA firmware 4.20x7 (2.65.1.416.65.65.101 8 Gb Gen8 Mezz (LPe1205A) firmware 2.HP Service Pack for ProLiant 2014.0 Release Notes Firmware 16Gb Standup & Mezzanine .1. Pause frame issue caused when additional RSS queues created and do not generate interrupts.12a14 BIOS 4.1.06. (required to support windows driver in SPP 2014. NC551i stops passing traffic when promiscuous mode is flipped on then off.20x7 (signed UEFI) Boot Image (BIOS) 8Gb Standup .1.20x7 (2.0).0 662 16 Gb HBA/Mezz universal boot 1.13a8 UEFI) HP | Service Pack for ProLiant 2014.4.13a8 UEFI) o Added UEFI support for 8Gb HBAs 82E & 81E Firmware 16Gb Standup & Mezzanine .12a14 BIOS.06.416.9.9. Enhancements Updated CNA firmware version to 4.1.65.0 o o o o o o Allow for use of iSCSI option during boot & BIOS on NC551i LOM.0 o Added support for VC 4.101 Updated 8Gb Standup Boot image version to 5.4.01a12 8 Gb HBA boot image 5.5.20.101 o o Point to Point configuration Performance Enhancement Added support for UEFI/Legacy BIOS boot CNA .9. 82x4 4 Gb Mezz boot image 6.0 DC HBA HP FC2242SR 4Gb PCIe DC Host Bus Adapter HP StorageWorks FC2143 4 Gb PCI-X 2.0 HBA HP FC2142SR 4Gb PCIe Host Bus Adapter HP SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter HP 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter HP 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter HP CN1000E Dual Port Converged Network Adapter HP CN1100E Dual Port Converged Network Adapter HP Flex-10 10Gb 2-port 552M Adapter HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter HP NC552m 10Gb 2-port FlexFabric Converged Network Adapter HP NC552SFP 10Gb 2-port Ethernet Server Adapter HP NC551m Dual Port FlexFabric 10Gb Converged Network Adapter HP NC551i Dual Port FlexFabric 10Gb Network Adapter HP NC550SFP Dual Port 10GbE Server Adapter HP FlexFabric 10Gb 2-port 554M Adapter HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 554FLB Adapter HP NC550m Dual Port Flex-10 10Gbe BL-c Adapter HP LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class Emulex LPe1205 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem Emulex LPe1105 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter HP SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter HP Fibre Channel 16Gb LPe1605 Mezz HP Firmware Online Flash for QLogic Fibre Channel Host Bus Adapters Windows 2008 (x86) Version: 2014.01 (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes 663 Prerequisites The HP supplied QLogic driver kit must be installed prior to this firmware component being identified by HP | Service Pack for ProLiant 2014.10a14 (3.04.30a2 BIOS) 4 Gb HBA/Mezz firmware 2.30a1 BIOS) 4 Gb HBA boot image 5.HP Service Pack for ProLiant 2014.10a15 (3.06.20a6 (2.12a14 BIOS) Supported Devices and Features o o o o o o o o o o o o o o o o o o o o o o o o o o o o HP StorageWorks FC2243 4 Gb PCI-X 2.0 .0 Release Notes 8 Gb Mezz boot image 6.06. 28 16 Gb HBA/Mezz o Enabled legacy BIOS boot o Enabled secure boot o o o o Package 3.03.0 HBA HP StorageWorks FC1243 4Gb PCI-X 2.hp. Select your product and then select the Software and Drivers page to find the required driver.06.09.00 BIOS 3.02 Firmware 6.com/go/fchba and www.com/go/cna.15  BIOS 3. o 4 Gb HBA/Mezz  Package 2.90.04  BIOS 3. Enhancements o Updated the firmware/BIOS packages for 8 Gb and 16 Gb products.13 o QMH2572 Mezz Card  Package 2.0 664 .13 o 8 Gb HBA/Mezz o Enabled legacy BIOS boot o Enabled secure boot o o o o o Package 3. The software is available from www.hp.59AF  Firmware 5.25 Supported Devices and Features This firmware supports the following HP adapters: o o o o HP StorageWorks FC1143 4Gb PCI-X 2.HP Service Pack for ProLiant 2014.06.60A4 Firmware 5.0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP | Service Pack for ProLiant 2014.0 Release Notes HP SUM for deployment.03AF  Firmware 5.06.02 BIOS 3.13 UEFI 6.21 UEFI 6.07. 01 (Optional) Important Note! Release Notes: HP StorageWorks QLogic Adapters Release Notes Prerequisites The HP supplied QLogic driver kit must be installed prior to this firmware component being identified by HP SUM for deployment.06.HP Service Pack for ProLiant 2014.13 UEFI 6.04  BIOS 3.09.59AF  Firmware 5.com/go/cna.03AF  Firmware 5.28 665 16 Gb HBA/Mezz HP | Service Pack for ProLiant 2014.0 .15  BIOS 3. Select your product and then select the Software and Drivers page to find the required driver.00 BIOS 3.06. The software is available from www.13 o 8 Gb HBA/Mezz  Enabled legacy BIOS boot  Enabled secure boot     o Package 3.04.13 o QMH2572 Mezz Card  Package 2. Enhancements o Updated the firmware/BIOS packages for 8 Gb and 16 Gb products o 4 Gb HBA/Mezz  Package 2.hp.0 Release Notes o o o o o o o HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP StoreFabric SN1000Q 16Gb Fibre Channel Host Bus Adapter HP QMH2672 16Gb FC HBA for c-Class BladeSystem HP Firmware Online Flash for QLogic Fibre Channel Host Bus Adapters Windows 2008/2012 (x64) Version: 2014.com/go/fchba and www.06.60A4 Firmware 5.03.hp. 0 666 .51 for SUSE LINUX Enterprise Server 11 (i686) or HP ProLiant Support Pack 8.– These drivers are available on HP.21 UEFI 6.8.06.0 Release Notes   Enabled legacy BIOS boot Enabled secure boot     Package 3.06.24-5 of HP ProLiant Smart Array Controller (x86/AMD32) Driver for SUSE LINUX Enterprise Server 11 (x86) or HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) .0 Dual Channel HBA HP FC1142SR 4Gb PCIe Host Bus Adapter HP FC1242SR 4Gb PCIe DC Host Bus Adapter HP 81Q PCIe Fibre Channel Host Bus Adapter HP 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter QLogic QMH2562 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem QLogic QMH2462 4Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem HP StoreFabric SN1000Q 16Gb Fibre Channel Host Bus Adapter HP QMH2672 16Gb FC HBA for c-Class BladeSystem Top Firmware .Storage Tape HP StoreEver Tape Firmware for Linux Version: 3.02 Firmware 6.HP Service Pack for ProLiant 2014.51 for SUSE LINUX Enterprise Server 11 (x86_64).COM as an individual downloads and bundled in the HP ProLiant Support Pack 8.90.25 Supported Devices and Features This firmware supports the following HP adapters: o o o o o o o o o o o HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA HP StorageWorks FC1243 4Gb PCI-X 2. HP | Service Pack for ProLiant 2014.0 (Optional) Important Note! On HP ProLiant G6/7 servers with an HP Smart Array P212 Storage Controller card.07. Note: When these drivers are installed on the target system.0.6. the driver filename begins with ‘cciss’.02 BIOS 3. an error can occur in the following configuration: • HP SAS Tape drive • HP Smart Array P212 Controller card • SUSE LINUX Enterprise Server 11 (x86) or SUSE LINUX Enterprise Server 11 (AMD64/EM64T) • Version 4. respectively. HP | Service Pack for ProLiant 2014. change the line “setting default=x” where x = any number. the firmware upgrade process cannot begin until the tape drive has completed processing of any current jobs. In this environment.0 Release Notes Upon installation of the above mentioned cciss driver. The Cartridge Memory update failed causing assert reset due to other internal firmware processes overflowing the queue. Reboot the system The system will now boot into the default SLES environment and allow expected functionality to occur. 1. Firmware race condition might cause a multi-partitioned cartridge to be reported as having only a single partition. will fail with an 0x1C2B error. When the tape drive is engaged in one of these jobs.06. Once the file is open. or verify jobs before attempting to upgrade the tape drive firmware from a Linux system. Open a command line terminal 2. attempting to update a SAS tape drive firmware results in the drive going offline (without updating the drive firmware) and the system must be rebooted to restore the drive connection. Fixes The fixes below are only applicable for the following firmware revisions and devices: HP StoreEver LTO-6 Ultrium 6650 SAS Tape Drive Drive firmware version O39D Update recommendation Recommended Supersedes O2BD o o o o o o Corner-case situations resulted in Space/Locate 0x5090/0x5092 reporting errors. an HP initrd boot environment is created and made the default. Save the file 5. An assert reset was possible on a load when re-initializing the write/read channel adaption routines.0 . restore. Prerequisites Make sure that the tape drive is available and not running any backup.06. The following workaround exists to allow firmware updates and expected drive results. copy. Enter the command: gedit/boot/grub/menu.lst 3.HP Service Pack for ProLiant 2014. Writing to partitioned tapes might result in 0x5092 errors being reported on subsequent reads. after loading a cleaning cartridge. to “setting default=0” 4. A firmware upgrade over the primary port. HP StoreEver LTO-6 Ultrium 6250 SAS Tape Drive Drive firmware version 338D Update recommendation Recommended Supersedes 32BD o 667 Corner-case situations resulted in Space/Locate 0x5090/0x5092 reporting errors. A Tape Alert flag 56 (0x38) was not being cleared when the issue was resolved. A firmware upgrade over the primary port. Poor performance when connected to some 6Gb SAS HBAs. New tapes labelled by a drive containing an earlier firmware revision might get reported as a blank tape. The Cartridge Memory update failed causing assert reset due to other internal firmware processes overflowing the queue. The drive might become unresponsive during writing due to internal hardware power-on sequencing.06.0 668 . A Tape Alert flag 56 (0x38) was not being cleared when the issue was resolved. Writing to partitioned tapes might result in 0x5092 errors being reported on subsequent reads. A Tape Alert 55 (0x37) error was not being triggered on a failure to thread the tape during a load.0 Release Notes o o o o o An assert reset was possible on a load when re-initializing the write/read channel adaption routines. Writing to partitioned tapes might result in 0x5092 errors being reported on subsequent reads. will fail with an 0x1C2B error. The Cartridge Memory update failed causing assert reset due to other internal firmware processes overflowing the queue.06. New tapes labelled by a drive containing an earlier firmware revision might get reported as a blank tape. Enhancements HP | Service Pack for ProLiant 2014. Firmware race condition might cause a multi-partitioned cartridge to be reported as having only a single partition. The Cartridge Memory update failed causing assert reset due to other internal firmware processes overflowing the queue.HP Service Pack for ProLiant 2014. after loading a cleaning cartridge. Forcing writes to the physical EOT (End Of Tape) might result in the last wrap getting overwritten under corner case conditions. Poor performance when connected to some 6Gb SAS HBAs. HP StoreEver LTO-5 Ultrium 3000 SAS Tape Drive Drive firmware version Z64D Update recommendation Recommended Supersedes Z5AD o o o o o o o o o Space/Locate 0x5090/0x5092 reporting errors that resulted from corner-case situations. Forcing writes to the physical EOT (End Of Tape) might result in the last wrap getting overwritten under corner case conditions. A Tape Alert 55 (0x37) error was not being triggered on a failure to thread the tape during a load. Writing to partitioned tapes might result in 0x5092 errors being reported on subsequent reads. The drive might become unresponsive during writing due to internal hardware power-on sequencing. HP StoreEver LTO-5 Ultrium 3280 SAS Tape Drive Drive firmware version X64D Update recommendation Recommended Supersedes X5BD o o o o o o o o o Space/Locate 0x5090/0x5092 reporting errors that resulted from corner-case situations. Increased tape speed during space/locates to reduce occurrences of 0x5090/0x5092 errors. Enhanced the process for the drive to request a cleaning tape and report associated Tape Alerts if a 0x7519 write fault is encountered. Improved spacing performance by eliminating an unnecessary reposition.06. Improved the internal drive logging. Changed servo parameter to make the drive more robust to media servo issues HP StoreEver LTO-5 Ultrium 3280 SAS Tape Drive Drive firmware version X64D Update recommendation Recommended Supersedes X5BD o o o o o o New Functionality: Added "cached" READ ATTRIBUTE command support to allow Cartridge Memory data to be accessed after the tape has been unloaded. Changed servo parameter to make the drive more robust to media servo issues HP StoreEver LTO-6 Ultrium 6250 SAS Tape Drive Drive firmware version 338D Update recommendation Recommended Supersedes 32BD o o o o Improved the internal drive logging. Added final checking of the calibrated Servo band position values to the servo band calibration routine. Enhanced the load rotation check to reduce unload failures. HP StoreEver LTO-5 Ultrium 3000 SAS Tape Drive Drive firmware version Z64D Update recommendation Recommended Supersedes Z5AD o 669 New Functionality: Added "cached" READ ATTRIBUTE command support to allow Cartridge HP | Service Pack for ProLiant 2014.HP Service Pack for ProLiant 2014.0 Release Notes The enhancements below are only applicable for the following firmware revisions and devices: HP StoreEver LTO-6 Ultrium 6650 SAS Tape Drive Drive firmware version O39D Update recommendation Recommended Supersedes O2BD o o o o Improved the internal drive logging. Added final checking of the calibrated Servo band position values to the servo band calibration routine. Enhanced the process for the drive to request a cleaning tape and report associated Tape Alerts if a 0x7519 write fault is encountered. Added final checking of the calibrated Servo band position values to the servo band calibration routine.06.0 . Improved spacing performance by eliminating an unnecessary reposition. Added final checking of the calibrated Servo band position values to the servo band calibration routine. Supported Devices and Features p>Supported tape drives and firmware revisons included in this package Tape Drive Firmware Revision HP DAT 72 USB ZU8B HP DAT 72 SCSI ZPBC HP DAT160 SCSI WP8A HP DAT160 USB WU8A HP DAT160 SAS WSB8 HP DAT320 USB VUA8 HP DAT320 SAS VSA6 HP Ultrium 232 SCSI P61D HP Ultrium 448 SCSI S65D HP Ultrium 448 SAS T65D HP Ultrium 460 SCSI F63D HP Ultrium 920 SCSI D22D HP Ultrium 920 SAS C26D HP Ultrium 920 SAS Q51D HP Ultrium 960 SCSI G66D HP Ultrium 1760 SAS U64D HP Ultrium 1760 SCSI W62D HP Ultrium 1840 SAS A63D HP Ultrium 1840 SCSI B63D HP Ultrium 3280 SAS X64D HP Ultrium 3000 SAS Z64D HP Ultrium 6250 SAS 338D HP Ultrium 6650 SAS O39D HP StoreEver Tape Firmware for Microsoft Windows Version: 3.0 (b) (Optional) Fixes HP | Service Pack for ProLiant 2014.0 Release Notes o o o o o Memory data to be accessed after the tape has been unloaded. Improved the internal drive logging.HP Service Pack for ProLiant 2014.06. Increased tape speed during space/locates to reduce occurrences of 0x5090/0x5092 errors.8.06. Enhanced the load rotation check to reduce unload failures.0.0 670 . 0 671 . will fail with an 0x1C2B error. The Cartridge Memory update failed causing assert reset due to other internal firmware processes overflowing the queue. Writing to partitioned tapes might result in 0x5092 errors being reported on subsequent reads. Writing to partitioned tapes might result in 0x5092 errors being reported on subsequent reads. will fail with an 0x1C2B error. A firmware upgrade over the primary port.06. Firmware race condition might cause a multi-partitioned cartridge to be reported as having only a single partition. Firmware race condition might cause a multi-partitioned cartridge to be reported as having only a single partition. The drive might become unresponsive during writing due to internal hardware power-on sequencing. HP StoreEver LTO-6 Ultrium 6250 SAS Tape Drive Drive firmware version 338D Update recommendation Recommended Supersedes 32BD o o o o o o Corner-case situations resulted in Space/Locate 0x5090/0x5092 reporting errors. Writing to partitioned tapes might result in 0x5092 errors being reported on subsequent reads. after loading a cleaning cartridge. An assert reset was possible on a load when re-initializing the write/read channel adaption routines.0 Release Notes The fixes below are only applicable for the following firmware revisions and devices: HP StoreEver LTO-6 Ultrium 6650 SAS Tape Drive Drive firmware version O39D Update recommendation Recommended Supersedes O2BD o o o o o o Corner-case situations resulted in Space/Locate 0x5090/0x5092 reporting errors. An assert reset was possible on a load when re-initializing the write/read channel adaption routines.HP Service Pack for ProLiant 2014. after loading a cleaning cartridge. The Cartridge Memory update failed causing assert reset due to other internal firmware processes overflowing the queue.06. HP | Service Pack for ProLiant 2014. HP StoreEver LTO-5 Ultrium 3280 SAS Tape Drive Drive firmware version X64D Update recommendation Recommended Supersedes X5BD o o o o o o Space/Locate 0x5090/0x5092 reporting errors that resulted from corner-case situations. A firmware upgrade over the primary port. New tapes labelled by a drive containing an earlier firmware revision might get reported as a blank tape. Forcing writes to the physical EOT (End Of Tape) might result in the last wrap getting overwritten under corner case conditions. Poor performance when connected to some 6Gb SAS HBAs. New tapes labelled by a drive containing an earlier firmware revision might get reported as a blank tape. A Tape Alert flag 56 (0x38) was not being cleared when the issue was resolved. Added final checking of the calibrated Servo band position values to the servo band calibration routine. Forcing writes to the physical EOT (End Of Tape) might result in the last wrap getting overwritten under corner case conditions.0 Release Notes o o o The Cartridge Memory update failed causing assert reset due to other internal firmware processes overflowing the queue. The Cartridge Memory update failed causing assert reset due to other internal firmware processes overflowing the queue. The drive might become unresponsive during writing due to internal hardware power-on sequencing. Enhanced the process for the drive to request a cleaning tape and report associated Tape Alerts if a 0x7519 write fault is encountered. A Tape Alert flag 56 (0x38) was not being cleared when the issue was resolved.HP Service Pack for ProLiant 2014. Changed servo parameter to make the drive more robust to media servo issues HP StoreEver LTO-6 Ultrium 6250 SAS Tape Drive Drive firmware version 338D Update recommendation Recommended Supersedes 32BD o o 672 Improved the internal drive logging. A Tape Alert 55 (0x37) error was not being triggered on a failure to thread the tape during a load. Poor performance when connected to some 6Gb SAS HBAs. A Tape Alert 55 (0x37) error was not being triggered on a failure to thread the tape during a load.06.0 . Enhancements The enhancements below are only applicable for the following firmware revisions and devices: HP StoreEver LTO-6 Ultrium 6650 SAS Tape Drive Drive firmware version O39D Update recommendation Recommended Supersedes O2BD o o o o Improved the internal drive logging. Writing to partitioned tapes might result in 0x5092 errors being reported on subsequent reads. HP StoreEver LTO-5 Ultrium 3000 SAS Tape Drive Drive firmware version Z64D Update recommendation Recommended Supersedes Z5AD o o o o o o o o o Space/Locate 0x5090/0x5092 reporting errors that resulted from corner-case situations. Added final checking of the calibrated Servo band position values to the servo band calibration HP | Service Pack for ProLiant 2014.06. Increased tape speed during space/locates to reduce occurrences of 0x5090/0x5092 errors. Added final checking of the calibrated Servo band position values to the servo band calibration routine. Added final checking of the calibrated Servo band position values to the servo band calibration routine. Enhanced the process for the drive to request a cleaning tape and report associated Tape Alerts if a 0x7519 write fault is encountered. Supported Devices and Features Supported tape drives and firmware revisons included in this package Tape Drive Firmware Revision HP DAT 72 USB ZU8B HP DAT 72 SCSI ZPBC HP DAT160 SCSI WP8A HP DAT160 USB WU8A HP DAT160 SAS WSB8 HP DAT320 USB VUA8 HP DAT320 SAS VSA6 HP Ultrium 232 SCSI P61D 673 HP | Service Pack for ProLiant 2014. Changed servo parameter to make the drive more robust to media servo issues HP StoreEver LTO-5 Ultrium 3280 SAS Tape Drive Drive firmware version X64D Update recommendation Recommended Supersedes X5BD o o o o o o New Functionality: Added "cached" READ ATTRIBUTE command support to allow Cartridge Memory data to be accessed after the tape has been unloaded. Enhanced the load rotation check to reduce unload failures. Improved the internal drive logging.06. Improved spacing performance by eliminating an unnecessary reposition.0 . Improved spacing performance by eliminating an unnecessary reposition. HP StoreEver LTO-5 Ultrium 3000 SAS Tape Drive Drive firmware version Z64D Update recommendation Recommended Supersedes Z5AD o o o o o o New Functionality: Added "cached" READ ATTRIBUTE command support to allow Cartridge Memory data to be accessed after the tape has been unloaded. Enhanced the load rotation check to reduce unload failures. Increased tape speed during space/locates to reduce occurrences of 0x5090/0x5092 errors. Improved the internal drive logging.06.HP Service Pack for ProLiant 2014.0 Release Notes o o routine. Enhancements This version adds support for the following features and enhancements: 674 .0 .HP Service Pack for ProLiant 2014.00 or later The management interface driver and management agents must be installed on the server.Lights-Out Management Headless Server Registry Update for Windows Version: 1.00 or later Integrated Lights-Out 3 firmware v1.0 (F) (Optional) Enhancements Allow installation on Windows Server 2012.0.0-0 (Recommended) Prerequisites This utility requires the following minimum firmware revisions: o o o Integrated Lights-Out 2 firmware v1.0.0 Release Notes HP Ultrium 448 SCSI S65D HP Ultrium 448 SAS T65D HP Ultrium 460 SCSI F63D HP Ultrium 920 SCSI D22D HP Ultrium 920 SAS C26D HP Ultrium 920 SAS Q51D HP Ultrium 960 SCSI G66D HP Ultrium 1760 SAS U64D HP Ultrium 1760 SCSI W62D HP Ultrium 1840 SAS A63D HP Ultrium 1840 SCSI B63D HP Ultrium 3280 SAS X64D HP Ultrium 3000 SAS Z64D HP Ultrium 6250 SAS 338D HP Ultrium 6650 SAS O39D Top Software .3. HP Lights-Out Online Configuration Utility for Linux (AMD64/EM64T) Version: 4.iLO Federation Management HP | Service Pack for ProLiant 2014.06.00 or later Integrated Lights-Out 4 firmware v1.06. 00 or later The management interface driver must be installed on the server.HP Service Pack for ProLiant 2014.0 .0 (Recommended) 675 Prerequisites HP | Service Pack for ProLiant 2014.00 or later Integrated Lights-Out 3 firmware v1.06.0 (Recommended) Prerequisites This utility requires the following minimum firmware revisions: o o o Integrated Lights-Out 2 firmware v1. Fixes None Enhancements This version adds support for the following features and enhancements: . Microsoft .0.3. Enhancements This version adds support for the following features and enhancements: .00 or later Integrated Lights-Out 4 firmware v1.00 or later Integrated Lights-Out 4 firmware v1.00 or later The management interface driver and management agents must be installed on the server.0 (full version) or later is required to launch HPONCFG GUI.iLO Federation Management HP Lights-Out Online Configuration Utility for Windows Server 2003/2008 Version: 4.3.0.06.0 (Recommended) Prerequisites This utility requires the following minimum firmware revisions: o o o Integrated Lights-Out 2 firmware v1.iLO Federation Management HP Lights-Out Online Configuration Utility for Windows 2003/2008/2012 x64 Editions Version: 4.0 Release Notes HP Lights-Out Online Configuration Utility for Linux (x86/AMD32) Version: 4.Net Framework 2.00 or later Integrated Lights-Out 3 firmware v1.3. 0 .0.00 or later Integrated Lights-Out 3 firmware v1.0 (full version) or later is required to launch HPONCFG GUI.12-1 (Optional) Fixes This version corrects an issue where the lock file permissions were set incorrectly. Fixes None Enhancements This version adds support for the following features and enhancements: .iLO Federation Management PFA Server Registry Update for Windows Version: 1.Network Broadcom Active Health System Agent for HP ProLiant Network Adapters for Linux i586 Version: 1. Access to the lock file is now restricted to the owner only.06. Top Software . Microsoft . Enhancements This software now supports the HP Ethernet 1Gb 2-port 332i Adapter.Net Framework 2.0 (E) (Optional) Enhancements Add support for Windows Server 2012 R2.0 Release Notes This utility requires the following minimum firmware revisions: o o o Integrated Lights-Out 2 firmware v1.00 or later Integrated Lights-Out 4 firmware v1.HP Service Pack for ProLiant 2014.06. Supported Devices and Features This software supports the following Broadcom network adapters: o o o o o HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter 676 HP | Service Pack for ProLiant 2014.00 or later The management interface driver must be installed on the server.0.0. Enhancements This software now supports the HP Ethernet 1Gb 2-port 332i Adapter.06.HP Service Pack for ProLiant 2014.0.0.13-1 (Optional) Enhancements HP | Service Pack for ProLiant 2014.13-1 (Optional) Enhancements Initial release.0 Release Notes o HP Ethernet 1Gb 2-port 332T Adapter Broadcom Active Health System Agent for HP ProLiant Network Adapters for Linux x86_64 Version: 1.0 677 . Supported Devices and Features This software supports the following network adapters: o o o o o o o HP FlexFabric 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP ProLiant Converged Network Utility for Linux x86_64 Version: 1. Access to the lock file is now restricted to the owner only. Supported Devices and Features This software supports the following Broadcom network adapters: o o o o o o HP Ethernet 1Gb 2-port 330i Adapter HP Ethernet 1Gb 4-port 331FLR Adapter HP Ethernet 1Gb 4-port 331i Adapter HP Ethernet 1Gb 4-port 331T Adapter HP Ethernet 1Gb 2-port 332i Adapter HP Ethernet 1Gb 2-port 332T Adapter HP ProLiant Converged Network Utility for Linux x86 Version: 1.12-1 (Optional) Fixes This version corrects an issue where the lock file permissions were set incorrectly.06.0. Supported Devices and Features This software supports the following network adapters: o o o o o o o HP FlexFabric 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP ProLiant Converged Network Utility for Windows Server 2008 Version: 1.0.12. Supported Devices and Features This software supports the following network adapters: o o o o o o o HP FlexFabric 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP ProLiant Converged Network Utility for Windows Server x64 Editions Version: 1.1 (Optional) Enhancements Initial release.06.12. Supported Devices and Features This software supports the following network adapters: o o o o o o o HP FlexFabric 10Gb 2-port 533FLR-T Adapter HP FlexFabric 10Gb 2-port 534FLB Adapter HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter HP FlexFabric 10Gb 2-port 534M Adapter HP FlexFabric 20Gb 2-port 630FLB Adapter HP FlexFabric 20Gb 2-port 630M Adapter HP StoreFabric CN1100R Dual Port Converged Network Adapter HP | Service Pack for ProLiant 2014.0 Release Notes Initial release.0 678 .1 (Optional) Enhancements Initial release.06.0.HP Service Pack for ProLiant 2014. 43.0 Release Notes Intel Active Health System Agent for HP ProLiant Network Adapters for Linux i586 Version: 1.1.0 .HP Service Pack for ProLiant 2014.43.1.0-1 (Optional) Enhancements This software now supports the following network adapters: o o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 2-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Ethernet 10Gb 2-port 562i Adapter 679 HP | Service Pack for ProLiant 2014.06.06.0-1 (Optional) Enhancements This software now supports the following network adapters: o o o o HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 1-port 364i Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Ethernet 10Gb 2-port 562i Adapter Supported Devices and Features This software supports the following Intel network adapters: o o o o o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 2-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter Intel Active Health System Agent for HP ProLiant Network Adapters for Linux x86_64 Version: 1. 64 (Optional) 680 Fixes Fixed issue in which “last lockup code” was not being reported in proper hex format.0 Release Notes Supported Devices and Features This software supports the following Intel network adapters: o o o o o o o o o o o o o o o o HP Ethernet 1Gb 2-port 361i Adapter HP Ethernet 1Gb 2-port 361FLB Adapter HP Ethernet 1Gb 2-port 361T Adapter HP Ethernet 1Gb 2-port 363i Adapter HP Ethernet 1Gb 2-port 364i Adapter HP Ethernet 1Gb 4-port 366FLR Adapter HP Ethernet 1Gb 4-port 366i Adapter HP Ethernet 1Gb 4-port 366M Adapter HP Ethernet 1Gb 2-port 367i Adapter HP Ethernet 10Gb 2-port 560FLB Adapter HP Ethernet 10Gb 2-port 560FLR-SFP+ Adapter HP Ethernet 10Gb 2-port 560M Adapter HP Ethernet 10Gb 2-port 560SFP+ Adapter HP Ethernet 10Gb 2-port 561FLR-T Adapter HP Ethernet 10Gb 2-port 561T Adapter HP Ethernet 10Gb 2-port 562i Adapter Top Software .36.0.0. Enhancements o o Added support for new PHY disabled event.HP Service Pack for ProLiant 2014. HP ProLiant Smart Array SAS/SATA Event Notification Service for Windows Server 2008 x64 Editions and Windows Server 2012 Version: 6.0 .06. Added support for new PHY threshold exceeded events.06. Enhancements HP | Service Pack for ProLiant 2014.36.Storage Controller HP ProLiant Smart Array SAS/SATA Event Notification Service for Windows Server 2008 (x86) 32-bit Version: 6.32 (Optional) Fixes Fixed issue in which “last lockup code” was not being reported in proper hex format. 2-6 (Optional) Prerequisites .Requires the following packages to be installed: glibc libgcc libstdc++ bash perl Enhancements o Updated for RHEL 5.9 HP Fibre Channel Enablement Kit for Linux Version: 2.0 Release Notes o o Added support for new PHY disabled event.0.0 (Optional) HP | Service Pack for ProLiant 2014.0. They are now vendor specific kits. 681 HP Fibre Channel Enablement Kit for Linux Version: 4.9 Fibreutils for HP Storage Fibre Channel Host Bus Adapters for Linux (x86_64) Version: 3. Enhancements This is the first release of the vendor specific kit.2-6 (Optional) Prerequisites .06.Storage Fibre Channel HBA Fibreutils for HP Storage Fibre Channel Host Bus Adapters for Linux (x86) Version: 3. Added support for new PHY threshold exceeded events.Requires the following packages to be installed: glibc libgcc libstdc++ bash perl Enhancements o Updated for RHEL5.0 . an update from a previously released version is not possible.06.0-4 (Recommended) Important Note! There has been a change to the enablement kits in this release. It contains support for only Qlogic adapters. Therefore.0.HP Service Pack for ProLiant 2014. Top Software .0. HP Service Pack for ProLiant 2014. They are now vendor specific kits.0.2-1 Top Software .System Management HP Insight Diagnostics Online Edition for Linux (x86 32-bit) Version: 9.0 .06. version 9.19. Enhancements updated version of 6. an update from a previously released version is not possible.64.0.0-12 or higher The following component(s) are recommended for HP Insight Diagnostics Online Edition for Linux to make full use of its capabilities: o HP System Health Application.0.0 or higher Fixes Contains fixes to support the next generation of HP servers.4.0.4.1262-1202 (Recommended) Prerequisites The following component(s) are required for HP Insight Diagnostics Online Edition for Linux: o HP System Management Homepage.0 Release Notes Enhancements Includes support for RHEL 6.0 (Optional) Enhancements Updated to version 4. Enhancements 682 Added support for new HP ProLiant Gen 8 servers: o HP ProLiant BL465c Gen8 Server HP | Service Pack for ProLiant 2014. version 7. HP Fibre Channel Enablement Kit for Linux Version: 6.06.0. HP Fibre Channel Enablement Kit for Linux Version: 4.5. Therefore.2-1 (Optional) Important Note! There has been a change to the enablement kits in this release.0.21.0. 06.1262-1202 (Recommended) Prerequisites The following component(s) are required for HP Insight Diagnostics Online Edition for Linux: o HP System Management Homepage.0 or higher Fixes Contains fixes to support next generation of HP servers. See the HP Service Pack for ProLiant Server Support Guide for information on supported servers.06.HP Service Pack for ProLiant 2014.0 Release Notes o o o o o o o HP ProLiant BL420c Gen8 Server HP ProLiant DL385p Gen8 Server HP ProLiant DL380e Gen8 Server HP ProLiant DL360e Gen8 Server HP ProLiant DL320e Gen8 Server HP ProLiant ML350e Gen8 Server HP ProLiant ML310e Gen8 Server See the HP Service Pack for ProLiant Release Notes for more information. Enhancements Added support for new HP ProLiant Gen 8 servers: o o o o o o o o HP ProLiant BL465c Gen8 Server HP ProLiant BL420c Gen8 Server HP ProLiant DL385p Gen8 Server HP ProLiant DL380e Gen8 Server HP ProLiant DL360e Gen8 Server HP ProLiant DL320e Gen8 Server HP ProLiant ML350e Gen8 Server HP ProLiant ML310e Gen8 Server See the HP Service Pack for ProLiant Release Notes for more information.0.64. See the HP Service Pack for ProLiant Server Support Guide for information on supported servers.0 683 . HP Insight Diagnostics Online Edition for Linux (x86-64) Version: 9.0-12 or higher The following component(s) are recommended for HP Insight Diagnostics Online Edition for Linux to make full use of its capabilities: o HP System Health Application. HP | Service Pack for ProLiant 2014. version 7.0. version 9. 0. There are currently no plans to add such support to the controllers.1262.0 or higher Fixes Contains fixes related to the next generation of HP server products.0.HP Service Pack for ProLiant 2014. version 7.0-12 or higher The following component(s) are recommended for HP Insight Diagnostics Online Edition for Linux to make full use of its capabilities: o o HP ProLiant Agentless Management Service. available from hp.5 or earlier.0 . version 1. version 8.06.0. the Survey feature no longer supports displaying properties of Logical Drives that are attached to certain Smart Array controllers. nor to add legacy support to future versions of HP Insight Diagnostics.0 (Recommended) Important Note! Known Limitations Under HP Insight Diagnostics Online Edition for Windows. can also display information about logical drives attached to these controllers. may be used to display logical drive properties in Survey.com.0. HP Insight Diagnostics Online Edition for Windows. version 9. The HP Array Configuration Utility.0 Release Notes HP Insight Diagnostics Online Edition for Windows Version: 9.15. As a work-around. either directly or through an enclosure (such as an HP Modular Smart Array). Prerequisites The following component(s) are required for HP Insight Diagnostics Online Edition for Linux: o HP System Management Homepage. The controllers affected are: o o o o o Smart Array 6i Controller Smart Array 641 Controller Smart Array 642 Controller Smart Array 6402 Controller Smart Array 6404 Controller These controllers do not support the commands used to obtain logical drive properties.0 or higher HP ProLiant Integrated Lights-Out Management Interface Driver.64.06. Enhancements Added support for new HP ProLiant Gen 8 servers: o o o 684 HP ProLiant BL465c Gen8 Server HP ProLiant BL420c Gen8 Server HP ProLiant DL385p Gen8 Server HP | Service Pack for ProLiant 2014. 0 . nor to add legacy support to future versions of HP Insight Diagnostics. version 1. The controllers affected are: o o o o o Smart Array 6i Controller Smart Array 641 Controller Smart Array 642 Controller Smart Array 6402 Controller Smart Array 6404 Controller These controllers do not support the commands used to obtain logical drive properties.0 or higher HP ProLiant Integrated Lights-Out Management Interface Driver. available from hp. HP Insight Diagnostics Online Edition for Windows. version 9. either directly or through an enclosure (such as an HP Modular Smart Array). version 7.com. Prerequisites The following component(s) are required for HP Insight Diagnostics Online Edition for Linux: o HP System Management Homepage.0.0. HP | Service Pack for ProLiant 2014.06.0.0 Release Notes o o o o o HP ProLiant DL380e Gen8 Server HP ProLiant DL360e Gen8 Server HP ProLiant DL320e Gen8 Server HP ProLiant ML350e Gen8 Server HP ProLiant ML310e Gen8 Server See the HP Service Pack for ProLiant Release Notes for more information.06. may be used to display logical drive properties in Survey.64. There are currently no plans to add such support to the controllers.0.HP Service Pack for ProLiant 2014.15.0-12 or higher The following component(s) are recommended for HP Insight Diagnostics Online Edition for Linux to make full use of its capabilities: o o HP ProLiant Agentless Management Service. the Survey feature no longer supports displaying properties of Logical Drives that are attached to certain Smart Array controllers. can also display information about logical drives attached to these controllers.5 or earlier.0 (Recommended) Important Note! Known Limitations Under HP Insight Diagnostics Online Edition for Windows. version 8. The HP Array Configuration Utility. As a work-around. HP Insight Diagnostics Online Edition for Windows x64 Editions Version: 9. See the HP Service Pack for ProLiant Server Support Guide for information on supported servers.1262.0 or higher 685 Fixes Contains fixes/enhancements related to next generation of HP server products. HP Insight Management Agents for Windows Server Version: 9. Embedded HP ILO4 NIC help page was updated. Alignment update on SMH->ILO embedded NIC page.50 failed to install/upgrade on Windows 2008 x64 and x86.90 NCU spec. IMA 9.0 686 .06. IMA 9.HP Service Pack for ProLiant 2014.0. Event selection option in the HP Event Notifier settings. The following items have been fixed: Initial USB status display on the SMH page.60. Added NVIDIA Quadro K2000 VGA card details.0 (Recommended) Prerequisites SNMP Service. HP Insight Management Agents for Windows Server x64 Editions Version: 9.50 failed to install on Windows 2008 when attempting to install VS2012 runtime. HP Insight Management Agents shows incorrect Installed/Active version. Windows agents now reads registry key for the OS Version. IML event log not updated when event log is cleared from SMH page.0.60. HP Insight Event Notifier Alert shows incorrect PCI slot # for Smart Array P812.0 Release Notes Enhancements Added support for new HP ProLiant Gen 8 servers: o o o o o o o o HP ProLiant BL465c Gen8 Server HP ProLiant BL420c Gen8 Server HP ProLiant DL385p Gen8 Server HP ProLiant DL380e Gen8 Server HP ProLiant DL360e Gen8 Server HP ProLiant DL320e Gen8 Server HP ProLiant ML350e Gen8 Server HP ProLiant ML310e Gen8 Server See the HP Service Pack for ProLiant Release Notes for more information.0 (Recommended) Prerequisites HP | Service Pack for ProLiant 2014. Fixes Server Agents: Added NIC device details as per 10. Agents service fails to start when selecting subagents from the control panel application. See the HP Service Pack for ProLiant Server Support Guide for information on supported servers.06. 0 require storage.0 (Optional) Prerequisites The HP Insight Management WBEM Providers version 9. and Lights-Out interface drivers from PSP 9. network.0 687 .0 Release Notes SNMP service. Agents service fails to start when selecting subagents from the control panel application. Fixes Server Agents: Added NIC device details as per 10. In addition. The following items have been fixed: Initial USB status display on the SMH page.00. IMA 9.90 NCU spec. the System Management Homepage (SMH) component is required for a single server web- HP | Service Pack for ProLiant 2014. HP Insight Management WBEM Providers for Windows Server Version: 9. Windows agents now reads registry key for the OS Version.00.HP Service Pack for ProLiant 2014.0. network. system management controller.06. IMA 9. Event selection option in the HP Event Notifier settings.50 failed to install/upgrade on Windows 2008 x64 and x86. system management controller.0. HP Insight Event Notifier Alert shows incorrect PCI slot # for Smart Array P812.5. and Lights-Out interface drivers from PSP 9. Enhancements o o Support for Unified Extensible Firware Interface Platforms Encryption status reporting for Smart Array controllers HP Insight Management WBEM Providers for Windows Server x64 Editions Version: 9. Embedded HP ILO4 NIC help page was updated. the System Management Homepage (SMH) component is required for a single server webbased user interface.0 (Optional) Prerequisites The HP Insight Management WBEM Providers version 9.50 failed to install on Windows 2008 when attempting to install VS2012 runtime. HP Insight Management Agents shows incorrect Installed/Active version.5.0.06.0. In addition.0. IML event log not updated when event log is cleared from SMH page.0. Added NVIDIA Quadro K2000 VGA card details.0 require storage. Alignment update on SMH->ILO embedded NIC page. 4.5. SuSE Linux Enterprise Server 11 SP1 Enhancements Added support for: o o o o o New HP ProLiant Gen8 Servers. Requirements: HP | Service Pack for ProLiant 2014. HP ProLiant Agentless Management Service for Red Hat Enterprise Linux 5 (x86) Version: 1.0 Release Notes based user interface.0 688 . The HP iLO 4 may need to be reset after changing these settings. Linux Operating System Management Functions (cpqLinOs (. Red Hat Enterprise Linux 6. The HP iLO 4 may need to be reset after changing these settings.06. MIB-II for IPv6.HP Service Pack for ProLiant 2014.6.5.1. Enhancements o o Support for Unified Extensible Firware Interface Platforms Encryption status reporting for Smart Array controllers HP ProLiant Agentless Management Service for Red Hat Enterprise Linux 5 (AMD64/EM64T) Version: 1. hp-ams provides information to the HP iLO 4 service providing SNMP support.23) MIBs).0.6.3. SNMP PASS-THRU on the HP iLO 4 MUST be disabled.0 (Optional) Prerequisites o o o o hp-ams only supported on HP ProLiant Gen8 Servers.4.1.1.05  Minimum supported OS Versions = Red Hat Enterprise Linux 5. UEFI (Unified Extensible Firmware Interface) platform.232) MIBs). and SNMP should be configured on the HP iLO 4.3.232.6.06. and SNMP should be configured on the HP iLO 4. Fibre Channel HBAs (cpqFca (.0 (Optional) Prerequisites o o o o hp-ams only supported on HP ProLiant Gen8 Servers.1. hp-ams provides information to the HP iLO 4 service providing SNMP support.1.1. SNMP PASS-THRU on the HP iLO 4 MUST be disabled. Requirements:  Minimum HP iLO 4 Firmware Version = 1. SuSE Linux Enterprise Server 10 SP4. 0.3.23) MIBs).HP Service Pack for ProLiant 2014.232) MIBs).1. hp-ams provides information to the HP iLO 4 service providing SNMP support.6. SuSE Linux Enterprise Server 10 SP4.6.0 .1. SNMP PASS-THRU on the HP iLO 4 MUST be disabled.4.4.05  Minimum supported OS Versions = Red Hat Enterprise Linux 5.1.6.6.0 Release Notes   Minimum HP iLO 4 Firmware Version = 1. Requirements:  Minimum HP iLO 4 Firmware Version = 1. Red Hat Enterprise Linux 6. HP ProLiant Agentless Management Service for Red Hat Enterprise Linux 6 (AMD64/EM64T) Version: 1.0. Fibre Channel HBAs (cpqFca (.3.1.4.232.05 Minimum supported OS Versions = Red Hat Enterprise Linux 5.1.0 (Optional) Prerequisites o o o o hp-ams only supported on HP ProLiant Gen8 Servers.0 (Optional) 689 Prerequisites o o hp-ams only supported on HP ProLiant Gen8 Servers.1.5.232) MIBs). UEFI (Unified Extensible Firmware Interface) platform.06.1.1. The HP iLO 4 may need to be reset after changing these settings. SuSE Linux Enterprise Server 10 SP4. Linux Operating System Management Functions (cpqLinOs (. Linux Operating System Management Functions (cpqLinOs (.1. HP | Service Pack for ProLiant 2014.4.1. MIB-II for IPv6. hp-ams provides information to the HP iLO 4 service providing SNMP support.232. and SNMP should be configured on the HP iLO 4.1.23) MIBs). SuSE Linux Enterprise Server 11 SP1 Enhancements Added support for: o o o o New HP ProLiant Gen8 Servers. HP ProLiant Agentless Management Service for Red Hat Enterprise Linux 6 (x86) Version: 1. MIB-II for IPv6.1. Red Hat Enterprise Linux 6. Fibre Channel HBAs (cpqFca (. SuSE Linux Enterprise Server 11 SP1 Enhancements Added support for: o o o o o New HP ProLiant Gen8 Servers.3.3.6.6.06.5. Linux Operating System Management Functions (cpqLinOs (.1.1. SuSE Linux Enterprise Server 11 SP1 Enhancements Added support for: o o o o New HP ProLiant Gen8 Servers. hp-ams provides information to the HP iLO 4 service providing SNMP support.0.6. The HP iLO 4 may need to be reset after changing these settings.3.1.0 Release Notes o o SNMP PASS-THRU on the HP iLO 4 MUST be disabled.1. and SNMP should be configured on the HP iLO 4.0. Fibre Channel HBAs (cpqFca (. Linux Operating System Management Functions (cpqLinOs (.1.232.6.6. and SNMP should be configured on the HP iLO 4.3.06.3. Requirements:  Minimum HP iLO 4 Firmware Version = 1.6.1.23) MIBs). MIB-II for IPv6.4.5.5.1.0 (Optional) Prerequisites HP | Service Pack for ProLiant 2014. Red Hat Enterprise Linux 6. HP ProLiant Agentless Management Service for SUSE LINUX Enterprise Server 11 (x86) Version: 1.232) MIBs). SNMP PASS-THRU on the HP iLO 4 MUST be disabled.4. MIB-II for IPv6.6. Fibre Channel HBAs (cpqFca (. SuSE Linux Enterprise Server 11 SP1 Enhancements Added support for: o o o o o New HP ProLiant Gen8 Servers.05  Minimum supported OS Versions = Red Hat Enterprise Linux 5.1. SuSE Linux Enterprise Server 10 SP4.1.4.6.232.0 (Optional) Prerequisites o o o o hp-ams only supported on HP ProLiant Gen8 Servers. SuSE Linux Enterprise Server 10 SP4.1.23) MIBs). Red Hat Enterprise Linux 6. HP ProLiant Agentless Management Service for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 1.1.232) MIBs).1.HP Service Pack for ProLiant 2014.0 690 . The HP iLO 4 may need to be reset after changing these settings. Requirements:  Minimum HP iLO 4 Firmware Version = 1.3.4. UEFI (Unified Extensible Firmware Interface) platform.05  Minimum supported OS Versions = Red Hat Enterprise Linux 5.06. HP ProLiant Agentless Management Service for Windows X64 Version: 9.0.0 691 .1.1. Capacity of hard drives greater than 2TB was reported as zero. hp-ams provides information to the HP iLO 4 service providing SNMP support.60. MIB-II for IPv6.0.1.1.23) MIBs).60.6.0 (Recommended) Prerequisites The HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64 (version 3.0 or later) must be installed prior to this component.06. and SNMP should be configured on the HP iLO 4.0. Hard drives in internal storage bays may have been reported as external storage. Fixes Corrected the following issues: o o o o o A memory leak that could cause the Agentless Management Service to rapidly consume all of the available memory on the system. The HP iLO 4 may need to be reset after changing these settings. Requirements:  Minimum HP iLO 4 Firmware Version = 1.3.232.1. Linux Operating System Management Functions (cpqLinOs (. Fibre Channel HBAs (cpqFca (.0.3.0 Release Notes o o o o hp-ams only supported on HP ProLiant Gen8 Servers. HP ProLiant Agentless Management Service for Windows X86 Version: 9.0. SuSE Linux Enterprise Server 11 SP1 Enhancements Added support for: o o o o New HP ProLiant Gen8 Servers.06. Red Hat Enterprise Linux 6.0 (Recommended) Prerequisites The HP ProLiant iLO 3/4 Channel Interface Driver for Windows X86 (version 3. Hard drive rotational speed was reported as "other".HP Service Pack for ProLiant 2014. Media type for solid state hard drives was not reported correctly.1. SuSE Linux Enterprise Server 10 SP4.4.05  Minimum supported OS Versions = Red Hat Enterprise Linux 5. SNMP PASS-THRU on the HP iLO 4 MUST be disabled.0 or later) must be installed prior to this component. Fixes HP | Service Pack for ProLiant 2014.6.4.4.4.232) MIBs).6. 0.0.0.2.06. Hard drives in internal storage bays may have been reported as external storage.0 has been enhanced with these new features: o o For HP DL980 G7 Server with Intel Xeon E7 family (Westmere-EX) processor  Set Processor Package State to “No Package State” to avoid getting WHEA Event ID 47 errors  Report Processor Package State setting For all HP DL980 G7 Server  Change Processor Core State of “Power Saver” power plan to "C3 State" to maximize power saving when system is optimized by System Providers  Update the list of recommended QFEs to match QFE list on Smart Update QFE CD for x64 (Version 9.0.0 of this application is the final version that will support installation under Windows Server 2003 x64 Edition.1 (Recommended) Enhancements System Providers 9.3.0.22. Starting with version 6. or iLO 4 management controllers.0. the dependencies on the HP ProLiant Remote Monitor Service and the HP ProLiant Remote IML Service have been removed. Media type for solid state hard drives was not reported correctly.0. this application requires Administrator privileges through Windows User Account Control. iLO 3.0 692 .0 (Optional) Important Note! Starting with version 7.0. this application will only install on HP ProLiant systems supporting the iLO 2. If you HP | Service Pack for ProLiant 2014.0.0.0. Capacity of hard drives greater than 2TB was reported as zero. Installation in a virtual machine is no longer supported. Starting with version 6.HP Service Pack for ProLiant 2014.5.0 Release Notes Corrected the following issues: o o o o o A memory leak that could cause the Agentless Management Service to rapidly consume all of the available memory on the system. HP ProLiant DL980 System Providers for Windows Server x64 Editions Version: 9.0.60) HP ProLiant Integrated Management Log Viewer for Windows Server x64 Editions Version: 7.0.0.06.3. This application no longer provides access to the Integrated Management Log on a remote system. Starting with version 5. Version 6. separate 32-bit and 64-bit releases of this application are available. Hard drive rotational speed was reported as "other". Provide additional details for System Power Fault events. Installation in a virtual machine is no longer supported. Version 5.0 of this application is the final version that will support installation under Windows Server 2003. or iLO 4 management controllers. Version 6. This application no longer provides access to the Integrated Management Log on a remote system.22.5. use Windows Add or Remove Programs to uninstall the 64-bit release before installing the earlier 32-bit version. HP ProLiant Integrated Management Log Viewer for Windows Server x86 Editions Version: 7. If you wish to downgrade to version 5.0.0. Existing ACUCLI scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility. HP Smart Storage Administrator (HP SSA) CLI for Linux Version: 1.HP Service Pack for ProLiant 2014. Starting with version 5. Enhancements Add new events to the Unrecoverable System Error class.0 and later of the 32-bit release will not install under 64-bit Windows. Enhancements Support for HP | Service Pack for ProLiant 2014.0.0.60-17. iLO 3. abilities. the dependencies on the HP ProLiant Remote Monitor Service and the HP ProLiant Remote IML Service have been removed. this application will only install on HP ProLiant systems supporting the iLO 2.0.0 or earlier.0. Provide additional details for System Power Fault events.0.2.0.0. installation is based on the Microsoft Installer (MSI). Enable installation under Windows Server 2012 R2.0. this application requires Administrator privileges through Windows User Account Control.0.0 Release Notes wish to downgrade to version 5. use Windows Add or Remove Programs to uninstall this application before installing the earlier version. Starting with version 6.0 (Optional) Important Note! Starting with version 7. a 64-bit release of this application is available.0.0 693 .22. Enhancements Add new events to the Unrecoverable System Error class.3.2.0. and supported devices. Starting with version 6.06.0 (Optional) Important Note! HP SSACLI will allow you to configure and manage your storage as before.06.0.21.0.0.0.0 or earlier.0. but now with additional features. Starting with version 5. 0 (Optional) Important Note! HP SSACLI will allow you to configure and manage your storage as before. Enhancements HP | Service Pack for ProLiant 2014. Existing ACUCLI scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility. Enhancements Support for Smart Array P230i Smart Array P530 Smart Array P531 Smart Array P830 Smart Array P830i HP Secure Encryption Rapid Rebuild Priority SSD OPO (Over Provisioning Optimization) 512e Physical Drive support Auto RAID 0 HP Smart Storage Administrator (HP SSA) CLI for Windows Version: 1. abilities. but now with additional features. but now with additional features.60.17.0 Release Notes Smart Array P230i Smart Array P530 Smart Array P531 Smart Array P830 Smart Array P830i HP Secure Encryption Rapid Rebuild Priority SSD OPO (Over Provisioning Optimization) 512e Physical Drive support Auto RAID 0 HP Smart Storage Administrator (HP SSA) CLI for Linux 64-bit Version: 1. Existing ACUCLI scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.06. and supported devices.HP Service Pack for ProLiant 2014.0 694 .60-17.0 (Optional) Important Note! HP SSACLI will allow you to configure and manage your storage as before. and supported devices. abilities.06. 0 (Optional) Important Note! HP SSACLI will allow you to configure and manage your storage as before. please download it from HP.17. but now with additional features.60-17.HP Service Pack for ProLiant 2014. If the HP System Management Homepage software is not already installed on your server. Existing ACUCLI scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility.0 695 .60.06.06. and supported devices.0 (Optional) Prerequisites The HP Smart Storage Administrator for Linux requires the HP System Management Homepage software to be installed on the server. abilities. HP | Service Pack for ProLiant 2014. Enhancements Support for Smart Array P230i Smart Array P530 Smart Array P531 Smart Array P830 Smart Array P830i HP Secure Encryption Rapid Rebuild Priority SSD OPO (Over Provisioning Optimization) 512e Physical Drive support Auto RAID 0 HP Smart Storage Administrator (HP SSA) for Linux Version: 1.0 Release Notes Support for Smart Array P230i Smart Array P530 Smart Array P531 Smart Array P830 Smart Array P830i HP Secure Encryption Rapid Rebuild Priority SSD OPO (Over Provisioning Optimization) 512e Physical Drive support Auto RAID 0 HP Smart Storage Administrator (HP SSA) CLI for Windows 64-bit Version: 1.com and install it before installing the HP Smart Storage Administrator for Linux. enter the following at the command prompt: hpssa -local The command will start HP SSA in a new Firefox browser window. To invoke. Enhancements Support for Smart Array P230i Smart Array P530 Smart Array P531 Smart Array P830 Smart Array P830i HP Secure Encryption Rapid Rebuild Priority SSD OPO (Over Provisioning Optimization) 512e Physical Drive support Auto RAID 0 HP Smart Storage Administrator (HP SSA) for Linux 64-bit Version: 1. but no longer required to run the HP SSA GUI. but no longer required to run the HP SSA GUI. This is only valid for the loopback interface. HP SSA will automatically stop.0 Release Notes IMPORTANT UPDATE: HP SSA (GUI) for Linux can now be run without requiring the HP System Management Homepage. HP SSA now supports a Local Application Mode for Linux. When the browser window is closed.0 (Optional) Prerequisites The HP Smart Storage Administrator for Linux requires the HP System Management Homepage software to be installed on the server. HP SSA will automatically stop. To invoke.0 . IMPORTANT UPDATE: HP SSA (GUI) for Linux can now be run without requiring the HP System Management Homepage. please download it from HP. The HP System Management Homepage is still supported. and not visible to external network connections. and not visible to external HP | Service Pack for ProLiant 2014. The HP System Management Homepage is still supported. When the browser window is closed. HP SSA now supports a Local Application Mode for Linux.HP Service Pack for ProLiant 2014. This is only valid for the loopback interface.06.06.60-17. If the HP System Management Homepage software is not already installed on your server.com and install it before installing the HP Smart Storage Administrator for Linux. enter the following at the command prompt: 696 hpssa -local The command will start HP SSA in a new Firefox browser window. HP Smart Array Advanced Pack 1. but now with additional features. Enhancements Support for Smart Array P230i Smart Array P530 Smart Array P531 Smart Array P830 Smart Array P830i HP Secure Encryption Rapid Rebuild Priority SSD OPO (Over Provisioning Optimization) 512e Physical Drive support Auto RAID 0 HP Smart Storage Administrator (HP SSA) for Windows Version: 1.06. HP SSA will allow you to configure and manage your storage as before.HP Service Pack for ProLiant 2014.06. with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online.0 (Optional) Important Note! HP SSA replaces the existing HP Array Configuration Utility.60. and supported devices. or ACU.0 and 2.17. with the appropriate firmware.0 .0 Release Notes network connections. Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility. abilities.0 features are now part of the baseline features of HP SSA. Enhancements Support for Smart Array P230i Smart Array P530 Smart Array P531 Smart Array P830 Smart Array P830i HP Secure Encryption Rapid Rebuild Priority SSD OPO (Over Provisioning Optimization) 512e Physical Drive support Auto RAID 0 697 HP | Service Pack for ProLiant 2014. HP Smart Array Advanced Pack 1. but now with additional features.06.0 HP SNMP Agents (hp-snmp-agents) version 8.0 HP System Management Homepage Templates (hp-smh-templates) version 8.17.0 (Optional) Important Note! HP SSA replaces the existing HP Array Configuration Utility.5. Existing ACU scripts should only need to make minimal changes such as calling the appropriate binary or executable in order to maintain compatibility. and supported devices. with the appropriate firmware. or ACU.60.0 and 2. HP | Service Pack for ProLiant 2014.1.0 was split into three individual rpm packages: o o o HP System Health Application and Command Line Utilities (hp-health) version 8.0.0 (Optional) Important Note! The HP System Health Application and Insight Management Agents (hpasm) version 8. abilities.1.0.0 698 . HP SSA will allow you to configure and manage your storage as before. with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. Enhancements Support for Smart Array P230i Smart Array P530 Smart Array P531 Smart Array P830 Smart Array P830i HP Secure Encryption Rapid Rebuild Priority SSD OPO (Over Provisioning Optimization) 512e Physical Drive support Auto RAID 0 HP SNMP Agents for Red Hat Enterprise Linux 5 (AMD64/EM64T) Version: 9.1.06.0 These three packages provide equivalent functionality as hpasm v8.0 features are now part of the baseline features of HP SSA.0 Release Notes HP Smart Storage Administrator (HP SSA) for Windows 64-bit Version: 1.HP Service Pack for ProLiant 2014.0 and allow for more modular installation choices. 0 These three packages provide equivalent functionality as hpasm v8.HP Service Pack for ProLiant 2014. IPv6 for iLO. HP SNMP Agents for Red Hat Enterprise Linux 5 (x86) Version: 9. Added support for the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter.0 (Optional) Important Note! The HP System Health Application and Insight Management Agents (hpasm) version 8.0 Release Notes Prerequisites The hp-health and hp-snmp-agents run as 32 bit applications in the x86_64 environment.06.06. Added support for the following storage controllers: o o HP Smart Array P530 Controller.rpm Enhancements Added support for: o o o New HP ProLiant Gen8 Servers.0 HP SNMP Agents (hp-snmp-agents) version 8.0 699 .0 was split into three individual rpm packages: o o o HP System Health Application and Command Line Utilities (hp-health) version 8. HP Smart Array P531 Controller.0 HP System Management Homepage Templates (hp-smh-templates) version 8.1. Prerequisites HP | Service Pack for ProLiant 2014. The Linux kernel 32 bit compatibility must be enabled (usual default for Linux) and the 32 bit compatibility libraries must be present.0.1.1.0 and allow for more modular installation choices. UEFI (Unified Extensible Firmware Interface) platform.5. HP Ethernet 1Gb 2-port 367i Adapter.0. HP Ethernet 10Gb 2-port 561i Adapter. To get the list of all dependency files for hp-snmp-agents type: rpm –qp –-requires hp-snmp-agents-<version>. IPv6 for iLO.06. HP | Service Pack for ProLiant 2014. Added support for the following storage controllers: o o HP Smart Array P530 Controller.rpm Enhancements Added support for: o o o New HP ProLiant Gen8 Servers. Added support for the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter.0 (Optional) Prerequisites The hp-health and hp-snmp-agents run as 32 bit applications in the x86_64 environment. HP Ethernet 1Gb 2-port 367i Adapter. HP SNMP Agents for Red Hat Enterprise Linux 6 (AMD64/EM64T) Version: 9.06. UEFI (Unified Extensible Firmware Interface) platform. The Linux kernel 32 bit compatibility must be enabled (usual default for Linux) and the 32 bit compatibility libraries must be present. IPv6 for iLO.HP Service Pack for ProLiant 2014.5.0 Release Notes To get the list of all dependency files for hp-snmp-agents type: rpm –qp –-requires hp-snmp-agents-<version>.0 . HP Ethernet 10Gb 2-port 561i Adapter. To get the list of all dependency files for hp-snmp-agents type: rpm –qp –-requires hp-snmp-agents-<version>. 700 Added support for the following network adapters: o o HP Ethernet 1Gb 2-port 363i Adapter.rpm Enhancements Added support for: o o New HP ProLiant Gen8 Servers. HP Smart Array P531 Controller. HP Ethernet 1Gb 2-port 367i Adapter. 0 (Optional) Prerequisites To get the list of all dependency files for hp-snmp-agents type: rpm –qp –-requires hp-snmp-agents-<version>. HP Ethernet 10Gb 2-port 561i Adapter.5.0 Release Notes o HP Ethernet 10Gb 2-port 561i Adapter. HP Ethernet 1Gb 2-port 367i Adapter. HP SNMP Agents for Red Hat Enterprise Linux 6 (x86) Version: 9. Added support for the following storage controllers: o o HP Smart Array P530 Controller. HP SNMP Agents for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 9.06. HP Smart Array P531 Controller.0 701 . HP Smart Array P531 Controller.06.0 (Optional) Prerequisites The hp-health and hp-snmp-agents run as 32 bit applications in the x86_64 environment. To get the list of all dependency files for hp-snmp-agents type: HP | Service Pack for ProLiant 2014.5. Added support for the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter. IPv6 for iLO. Added support for the following storage controllers: o o HP Smart Array P530 Controller.rpm Enhancements Added support for: o o New HP ProLiant Gen8 Servers.HP Service Pack for ProLiant 2014. The Linux kernel 32 bit compatibility must be enabled (usual default for Linux) and the 32 bit compatibility libraries must be present. Added support for the following storage controllers: o o HP Smart Array P530 Controller.rpm Enhancements Added support for: o o New HP ProLiant Gen8 Servers.0 (Optional) Prerequisites To get the list of all dependency files for hp-snmp-agents type: rpm –qp –-requires hp-snmp-agents-<version>.rpm Enhancements Added support for: o o o New HP ProLiant Gen8 Servers. HP Ethernet 1Gb 2-port 367i Adapter. Added support for the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter. HP Smart Array P531 Controller. HP SNMP Agents for SUSE LINUX Enterprise Server 11 (x86) Version: 9. IPv6 for iLO. HP Ethernet 10Gb 2-port 561i Adapter. Added support for the following network adapters: o o o HP Ethernet 1Gb 2-port 363i Adapter. HP | Service Pack for ProLiant 2014. HP Ethernet 1Gb 2-port 367i Adapter. UEFI (Unified Extensible Firmware Interface) platform.06. HP Smart Array P531 Controller.5. Added support for the following storage controllers: o o 702 HP Smart Array P530 Controller. IPv6 for iLO.0 Release Notes rpm –qp –-requires hp-snmp-agents-<version>. HP Ethernet 10Gb 2-port 561i Adapter.HP Service Pack for ProLiant 2014.06.0 . 0 HP System Management Homepage Templates (hp-smh-templates) version 8.1.5.0.5.1.0.0 HP SNMP Agents (hp-snmp-agents) version 8.HP Service Pack for ProLiant 2014.0 was split into three individual rpm packages: o o HP System Health Application and Command Line Utilities (hp-health) version 8.06.0 HP SNMP Agents (hp-snmp-agents) version 8.0 (Optional) Important Note! The HP System Health Application and Insight Management Agents (hpasm) version 8.1.1.06.0. type: rpm –qp –requires hp-health-< version >.0 These three packages provide equivalent functionality as hpasm v8.0 HP | Service Pack for ProLiant 2014. UEFI (Unified Extensible Firmware Interface) platform. The Linux kernel 32 bit compatibility must be enabled (usual default for Linux) and the 32 bit compatibility libraries must be present.1. Prerequisites The hp-health and hp-snmp-agents run as 32 bit applications in the x86_64 environment.0 (Optional) Important Note! The HP System Health Application and Insight Management Agents (hpasm) version 8.0 was split into three individual rpm packages: o o o HP System Health Application and Command Line Utilities (hp-health) version 8.rpm Enhancements Added support for: o o o New HP ProLiant Gen8 Servers.0 703 .0 and allow for more modular installation choice. HP System Health Application and Command Line Utilities for Red Hat Enterprise Linux 5 (x86) Version: 9. To get the list of all dependency files for hp-health.0 Release Notes HP System Health Application and Command Line Utilities for Red Hat Enterprise Linux 5 (AMD64/EM64T) Version: 9. Enhanced hpbootcfg functionalities (UEFI) as per the new EV (Environment variables) specs. To get the list of all dependency files for hp-health.0.0 Release Notes o HP System Management Homepage Templates (hp-smh-templates) version 8.06.0 .rpm Enhancements Added support for: o o New HP ProLiant Gen8 Servers.5. type: rpm –qp –requires hp-health-< version >. Enhanced hpbootcfg functionalities (UEFI) as per the new EV (Environment variables) specs.1.0 and allow for more modular installation choice.rpm Enhancements Added support for: o o o New HP ProLiant Gen8 Servers. Enhanced hpbootcfg functionalities (UEFI) as per the new EV (Environment variables) specs.0 (Optional) 704 Prerequisites HP | Service Pack for ProLiant 2014.06. UEFI (Unified Extensible Firmware Interface) platform. HP System Health Application and Command Line Utilities for Red Hat Enterprise Linux 6 (x86) Version: 9.0 (Optional) Prerequisites The hp-health and hp-snmp-agents run as 32 bit applications in the x86_64 environment. Prerequisites To get the list of all dependency files for hp-health. HP System Health Application and Command Line Utilities for Red Hat Enterprise Linux 6 (AMD64/EM64T) Version: 9. type: rpm –qp –requires hp-health-< version >. The Linux kernel 32 bit compatibility must be enabled (usual default for Linux) and the 32 bit compatibility libraries must be present.5.HP Service Pack for ProLiant 2014.0 These three packages provide equivalent functionality as hpasm v8. 5.rpm 705 Enhancements Added support for: HP | Service Pack for ProLiant 2014. HP System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 9. type: rpm –qp –requires hp-health-< version >. type: rpm –qp –requires hp-health-< version >.0 . The Linux kernel 32 bit compatibility must be enabled (usual default for Linux) and the 32 bit compatibility libraries must be present.5.HP Service Pack for ProLiant 2014.rpm Enhancements Added support for: o o o New HP ProLiant Gen8 Servers. To get the list of all dependency files for hp-health.06.0 (Optional) Prerequisites To get the list of all dependency files for hp-health.0 Release Notes To get the list of all dependency files for hp-health. type: rpm –qp –requires hp-health-< version >. HP System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 11 (x86) Version: 9. UEFI (Unified Extensible Firmware Interface) platform.0 (Optional) Prerequisites The hp-health and hp-snmp-agents run as 32 bit applications in the x86_64 environment.rpm Enhancements Added support for: o o New HP ProLiant Gen8 Servers. Enhanced hpbootcfg functionalities (UEFI) as per the new EV (Environment variables) specs.06. Enhanced hpbootcfg functionalities (UEFI) as per the new EV (Environment variables) specs. hp. To remove this vulnerability from SMH.06.0.0 Release Notes o o New HP ProLiant Gen8 Servers.www2. Enhanced hpbootcfg functionalities (UEFI) as per the new EV (Environment variables) specs.pem & file.06. In case it is suspected that the infrastructure has been compromised.hp.2-1 (Critical) Prerequisites The rpm will check for prerequisites. Users can safely upgrade to these versions of SMH.3-1 (Critical) Important Note! Installation instructions for SMH 7. The table included below can be used to select the correct version to install.3.HP Service Pack for ProLiant 2014.3.com/portal/site/hpsc/public/kb/docDisplay/?docId=c0403076 6)  From a central location. to update on multiple nodes. cert. the user needs to delete the SMH certificate (or take back-up by copying it to a private folder). HP System Management Homepage for Linux (AMD64/EM64T) Version: 7.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04030739). New certificates will be created when SMH service starts (at the end of the upgrade or new installation).pem available inC:\hp\sslshare (on Windows) & /etc/opt/hp/sslshare (on Linux).hp.3 are full builds that include an updated version of OpenSSL (1. either of the following two methods can be used:  Using HP-SUM (more details in Section 5 of above mentioned SMH install guides)  Using HP-SIM (Refer to Section 3 of SIM user guide.1h). For details refer to Section 17 of SIM User guide for 7.0 706 . Fixes Provides fix for CVE-2014-0160.3 o o o o o SMH versions 7.3 installation and upgrade guide (http://h20564. not the complete SPP.3 (http://h20564.3. For 7.com/portal/site/hpsc/public/kb/docDisplay/?docI HP | Service Pack for ProLiant 2014.3 http://h20564.www2. HP System Management Homepage for Linux (AMD64/EM64T) Version: 7. For 7. even if the corresponding service is stopped or disabled  For Windows:  Service name: SysMgmtHp and display name: HP System Management Homepage  For Linux:  Service name: hpsmhd SMH can be upgraded by following any of the below methods:  Direct upgrade on each individual nodes by following the upgrade steps documented in Installation guides.3 installation refer to 7.www2.3. The SMH certificate can be found on each node of the data center as.3. only SMH needs to be upgraded. using SIM’s Custom Tool option. The delete file command (for deleting certificates) can be centrally executed for multiple nodes. 0 Release Notes d=c04030739 ) If you believe your SMH installation was exploited while it was running components vulnerable to CVEs reported against OpenSSL. recreating. Will updated systems require a reboot after applying the SMH patch? No. Will new certificates be issued along with the patch. Installing the new build is sufficient to get back to the normal state. 5. Select “HP Insight Management” under ‘Product and Solutions’ & check “HP System Management Homepage” to get SMH related documents. there are some steps to perform after you’ve upgraded to the nonvulnerable components. Where can I get SMH documentation? All major documents are available at: http://h17007. If you suspect your systems using SMH were exploited while they were vulnerable. o Is a FW Update necessary in addition to the SMH patch? No. or need to be handled separately? If you suspect the certificate has been compromised due to this vulnerability. Though SMH uses OS credentials using OS-based APIs.www1. otherwise use Username/Password OR set either “Trust by Name” or “Trust All” option in VCRM’s SMH to reestablish the connection. only the SMH update is sufficient to remove the vulnerable version of SMH.06.0 . When VCA’s SMH certificate is deleted & regenerated (as suggested before). If you use HPSIM’s “2-way trust” feature. These steps include revoking. New certificate will be created when SMH service starts (at the end of the fresh / upgrade installation). reboot of the system will not be required.hp.06. user provided credentials are passed from the client (browser) to the server (SMH) using the HTTPS protocol. Instructions on deleting the certificate are in the notes above. FAQs: 9. 4. new certificate needs to be (re)imported. or SMH will reuse the existing certificate. If VCA use “Using Certificate” option to connect to VCRM and VCRM’s SMH is configured with “Trust by Certificate” option.com/us/en/enterprise/servers/solutions/info-library. you will also need to revoke those SMH certificated from HPSIM and reimport the newly created SMH certificates.VCRM communication: The communication will be Impacted. What are the recommended upgrade paths? 707 SMH DVD SPP OpenSSL Recommended version of SMH for upgrade Linux OS Windows (except Win2003 & 2003 HP | Service Pack for ProLiant 2014. o o o Impact on VCA . and re-importing certificates and resetting passwords that might have been harvested by a malicious attacker using the known vulnerability. we do recommend to delete and revoke the certificate. these passwords need to be reset. and have imported SMH certificates into HPSIM.HP Service Pack for ProLiant 2014. 3. txt) HP System Management Homepage for Linux (x86) Version: 7. When VCA’s SMH certificate is deleted & regenerated (as suggested before). 8.2 2012.0.3.0.openssl.1.3.3 7.0 Release Notes R2) OS 7.06.3 7.0 708 .2 7.0 7.0.1 7.3.2.3.3. new certificate needs to be (re)imported.1c 7.3.1c 7.3.0 openssl-1.2.0 7.3 7.3 openssl-1. Should I reset password on all managed nodes.3.02. If VCA use “Using Certificate” option to connect to VCRM and VCRM’s SMH is configured with “Trust by Certificate” option.1.3. Fixes Patched to address SSL/TLS MITM Vulnerability CVE-2014-0224 (http://www.0 7.2.org/news/secadv_20140605.09.0 (B) openssl-1.3 openssl-1.1e 7.3.3 7.3.0.3.0.02.3 7.0 (B) 7.3 7. otherwise use Username/Password OR set either “Trust by Name” or “Trust All” option in VCRM’s SMH to reestablish the connection. Fixes Provides fix for CVE-2014-0160.0 2013.3 7.3.0. HP | Service Pack for ProLiant 2014.3.06.3. How can I verify whether my setup is patched successfully? SMH version can be verified by executing following command on: o o Windows: “hp\hpsmh\bin\smhlogreader –version” Linux: “/opt/hp/hpsmh/bin/smhlogreader –version” o Will VCA-VCRM communication be impacted due to the SMH certificate being deleted? The communication will be Impacted.1e 7. Prerequisites The rpm will check for prerequisites.3 openssl-1. user-provided credentials are passed from the client (browser) to the server (SMH) using the HTTPS protocol.1c 7.1c 7.2u2 openssl-1.0.HP Service Pack for ProLiant 2014.3 7.3 7.0.2-1 (Critical) Prerequisites The rpm will search for prerequisites and notify the user of any not present on the machine.3.2 6.1 2014.2.2.3 7.2 7.3.3.1g 7. Passwords need to be reset if you suspect the vulnerable version of SMH was exploited by malicious users/ hackers.3 openssl-1.3.3.3.0 7.2u1 openssl-1.1g 7.3 7. where SMH was/is running? Though SMH uses OS credentials using OS based APIs.3 2013.1 7.10.3.3 7. otherwise use Username/Password OR set either “Trust by Name” or “Trust All” option in VCRM’s SMH to reestablish the connection. and have imported SMH certificates into HPSIM. For 7. the user needs to delete the SMH certificate (or take back-up by copying it to a private folder).3. Users can safely upgrade to these versions of SMH. These steps include revoking.VCRM communication: The communication will be Impacted. For details refer to Section 17 of SIM User guide for 7. recreating.0 Release Notes HP System Management Homepage for Linux (x86) Version: 7.com/portal/site/hpsc/public/kb/docDisplay/?docId=c0403076 6)  From a central location.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04030739). you will also need to revoke those SMH certificated from HPSIM and reimport the newly created SMH HP | Service Pack for ProLiant 2014.com/portal/site/hpsc/public/kb/docDisplay/?docI d=c04030739 ) If you believe your SMH installation was exploited while it was running components vulnerable to CVEs reported against OpenSSL.06. New certificates will be created when SMH service starts (at the end of the upgrade or new installation). If VCA use “Using Certificate” option to connect to VCRM and VCRM’s SMH is configured with “Trust by Certificate” option. not the complete SPP.www2. In case it is suspected that the infrastructure has been compromised. either of the following two methods can be used:  Using HP-SUM (more details in Section 5 of above mentioned SMH install guides)  Using HP-SIM (Refer to Section 3 of SIM user guide.3 are full builds that include an updated version of OpenSSL (1.3 http://h20564.3.3 (http://h20564.1h).0 709 .3-1 (Critical) Important Note! Installation instructions for SMH 7. o o Impact on VCA . The delete file command (for deleting certificates) can be centrally executed for multiple nodes. For 7.www2. using SIM’s Custom Tool option.hp. The SMH certificate can be found on each node of the data center as.0.3.3 o o o o o SMH versions 7.pem available inC:\hp\sslshare (on Windows) & /etc/opt/hp/sslshare (on Linux). When VCA’s SMH certificate is deleted & regenerated (as suggested before).www2. To remove this vulnerability from SMH.pem & file. cert. new certificate needs to be (re)imported. If you use HPSIM’s “2-way trust” feature. to update on multiple nodes. The table included below can be used to select the correct version to install.HP Service Pack for ProLiant 2014. and re-importing certificates and resetting passwords that might have been harvested by a malicious attacker using the known vulnerability.3.3 installation refer to 7. there are some steps to perform after you’ve upgraded to the nonvulnerable components.hp.hp.06.3 installation and upgrade guide (http://h20564. even if the corresponding service is stopped or disabled  For Windows:  Service name: SysMgmtHp and display name: HP System Management Homepage  For Linux:  Service name: hpsmhd SMH can be upgraded by following any of the below methods:  Direct upgrade on each individual nodes by following the upgrade steps documented in Installation guides. only SMH needs to be upgraded. 3 openssl-1. or SMH will reuse the existing certificate.3.1c 7.1c 7.3 openssl-1.0.3.0 710 .06.1.0.3 7.3. or need to be handled separately? If you suspect the certificate has been compromised due to this vulnerability.3 openssl-1. Though SMH uses OS credentials using OS-based APIs. New certificate will be created when SMH service starts (at the end of the fresh / upgrade installation).0 7.0.0 7.2.0 7. user provided credentials are passed from the client (browser) to the server (SMH) using the HTTPS protocol. these passwords need to be reset.1 7.0.2u2 2013. Instructions on deleting the certificate are in the notes above.1c 7.02.0 (B) 7.0 (B) 7. Where can I get SMH documentation? All major documents are available at: http://h17007.2. 4.3.1e 7.3.3. What are the recommended upgrade paths? Recommended version of SMH for upgrade SMH DVD SPP OpenSSL 7.HP Service Pack for ProLiant 2014. FAQs: 9. 3.3.2.3.com/us/en/enterprise/servers/solutions/info-library. o Is a FW Update necessary in addition to the SMH patch? No. only the SMH update is sufficient to remove the vulnerable version of SMH.1g 7.3 openssl-1.3. 5.2 7.0 Linux OS Windows (except Win2003 & 2003 R2) OS openssl-1.0 Release Notes o certificates.hp.3.3 7. Will updated systems require a reboot after applying the SMH patch? No.3.0 2013.1.3.3 openssl-1.3.3 openssl-1.3. Installing the new build is sufficient to get back to the normal state.3 7.2 7.02.3.0.1e 7.2 2012.3. Select “HP Insight Management” under ‘Product and Solutions’ & check “HP System Management Homepage” to get SMH related documents.3.2 2014.0.3 7.10.www1.0 7.3. we do recommend to delete and revoke the certificate.0.3 7.0.3 openssl-1. If you suspect your systems using SMH were exploited while they were vulnerable.3 7.2.1c 7.3 HP | Service Pack for ProLiant 2014.3.06. reboot of the system will not be required.1 7.3 7.3 7. Will new certificates be issued along with the patch.1 7.09.3 7.3.1g 7.2.2u1 7.3. cert. only SMH needs to be upgraded. Users can safely upgrade to these versions of SMH. The SMH certificate can be found on each node of the data center as.1 (Critical) Important Note! Installation instructions for SMH 7. New certificates will be created when SMH service starts (at the end of the upgrade or new installation). In case it is suspected that the infrastructure has been compromised.06.3. not the complete SPP. Will VCA-VCRM communication be impacted due to the SMH certificate being deleted? The communication will be Impacted.0 Release Notes 6. How can I verify whether my setup is patched successfully? SMH version can be verified by executing following command on: o Windows: “hp\hpsmh\bin\smhlogreader –version” o Linux: “/opt/hp/hpsmh/bin/smhlogreader –version” 7.www2.3 (http://h20564.HP Service Pack for ProLiant 2014. The table included below can be used to select the correct version to install.3. 8.0.txt) HP System Management Homepage for Windows x64 Version: 7.3. otherwise use Username/Password OR set either “Trust by Name” or “Trust All” option in VCRM’s SMH to reestablish the connection. user-provided credentials are passed from the client (browser) to the server (SMH) using the HTTPS protocol. Prerequisites The rpm will search for prerequisites and notify the user of any not present on the machine. where SMH was/is running? Though SMH uses OS credentials using OS based APIs.06.openssl. The delete file command (for deleting certificates) can be centrally executed for multiple nodes.org/news/secadv_20140605. the user needs to delete the SMH certificate (or take back-up by copying it to a private folder).hp. Passwords need to be reset if you suspect the vulnerable version of SMH was exploited by malicious users/ hackers. When VCA’s SMH certificate is deleted & regenerated (as suggested before).pem & file. Should I reset password on all managed nodes. even if the corresponding service is stopped or disabled HP | Service Pack for ProLiant 2014. using SIM’s Custom Tool option. For details refer to Section 17 of SIM User guide for 7.1h). If VCA use “Using Certificate” option to connect to VCRM and VCRM’s SMH is configured with “Trust by Certificate” option.0 711 .3.3 o o o o SMH versions 7. Fixes Patched to address SSL/TLS MITM Vulnerability CVE-2014-0224 (http://www.pem available inC:\hp\sslshare (on Windows) & /etc/opt/hp/sslshare (on Linux). new certificate needs to be (re)imported.3 are full builds that include an updated version of OpenSSL (1. To remove this vulnerability from SMH.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04030739). and have imported SMH certificates into HPSIM. Installing the new build is sufficient to get back to the normal state. you will also need to revoke those SMH certificated from HPSIM and reimport the newly created SMH certificates. If you use HPSIM’s “2-way trust” feature.0 Release Notes  o For Windows:  Service name: SysMgmtHp and display name: HP System Management Homepage  For Linux:  Service name: hpsmhd SMH can be upgraded by following any of the below methods:  Direct upgrade on each individual nodes by following the upgrade steps documented in Installation guides. there are some steps to perform after you’ve upgraded to the nonvulnerable components. either of the following two methods can be used:  Using HP-SUM (more details in Section 5 of above mentioned SMH install guides)  Using HP-SIM (Refer to Section 3 of SIM user guide.hp. FAQs: 9.hp.www2. For 7.3 installation and upgrade guide (http://h20564. 3. When VCA’s SMH certificate is deleted & regenerated (as suggested before).06. If VCA use “Using Certificate” option to connect to VCRM and VCRM’s SMH is configured with “Trust by Certificate” option. recreating. For 7.3.com/portal/site/hpsc/public/kb/docDisplay/?docI d=c04030739 ) If you believe your SMH installation was exploited while it was running components vulnerable to CVEs reported against OpenSSL. or need to be handled separately? If you suspect the certificate has been compromised due to this vulnerability.0 712 . New certificate will be created when HP | Service Pack for ProLiant 2014. These steps include revoking. otherwise use Username/Password OR set either “Trust by Name” or “Trust All” option in VCRM’s SMH to reestablish the connection. Will updated systems require a reboot after applying the SMH patch? No. new certificate needs to be (re)imported. reboot of the system will not be required.com/portal/site/hpsc/public/kb/docDisplay/?docId=c0403076 6)  From a central location. or SMH will reuse the existing certificate. Will new certificates be issued along with the patch.3 http://h20564.3 installation refer to 7.HP Service Pack for ProLiant 2014.VCRM communication: The communication will be Impacted.www2. o o o Impact on VCA . we do recommend to delete and revoke the certificate. and re-importing certificates and resetting passwords that might have been harvested by a malicious attacker using the known vulnerability. to update on multiple nodes. these passwords need to be reset. Though SMH uses OS credentials using OS-based APIs. user provided credentials are passed from the client (browser) to the server (SMH) using the HTTPS protocol. o Is a FW Update necessary in addition to the SMH patch? No. If you suspect your systems using SMH were exploited while they were vulnerable.06. only the SMH update is sufficient to remove the vulnerable version of SMH. 3 openssl-1.3.3 7.2.1g 7.3 openssl-1.0 2013.1 7.2 2012.0.3.1c 7.3.0 7.09.02. Instructions on deleting the certificate are in the notes above.3 7.3 openssl-1.3.0 7.3 openssl-1. 4.3.3.3.1.HP Service Pack for ProLiant 2014.1.1 7.3 openssl-1.3 7.3.3 How can I verify whether my setup is patched successfully? SMH version can be verified by executing following command on: o o o Windows: “hp\hpsmh\bin\smhlogreader –version” Linux: “/opt/hp/hpsmh/bin/smhlogreader –version” Will VCA-VCRM communication be impacted due to the SMH certificate being deleted? The communication will be Impacted.2.1g 7. Select “HP Insight Management” under ‘Product and Solutions’ & check “HP System Management Homepage” to get SMH related documents. If VCA use “Using Certificate” option to connect to VCRM and VCRM’s SMH is configured with “Trust by Certificate” option.0 (B) 7. HP | Service Pack for ProLiant 2014.0 (B) 7.2.0. When VCA’s SMH certificate is deleted & regenerated (as suggested before).3.1e 7.06. Passwords need to be reset if you suspect the vulnerable version of SMH was exploited by malicious users/ hackers.3.com/us/en/enterprise/servers/solutions/info-library.0. What are the recommended upgrade paths? Recommended version of SMH for upgrade SMH DVD SPP OpenSSL 7.0.1 7.0 .3.2 7.3.3.3. 2014.3 7.0.3. new certificate needs to be (re)imported.3 openssl-1.2u1 7.3 7.2u2 2013.10.0.3 7. where SMH was/is running? 713 Though SMH uses OS credentials using OS based APIs.2.2 6.0 Linux OS Windows (except Win2003 & 2003 R2) OS openssl-1.1c 7.3.2.2 7.3.3 7.hp.3 7.1c 7.0 7. Where can I get SMH documentation? All major documents are available at: http://h17007. otherwise use Username/Password OR set either “Trust by Name” or “Trust All” option in VCRM’s SMH to reestablish the connection.3.0.3.3 7. user-provided credentials are passed from the client (browser) to the server (SMH) using the HTTPS protocol.0 Release Notes SMH service starts (at the end of the fresh / upgrade installation).0.3. 5.0 7. 8.02.3 openssl-1.3.1e 7. Should I reset password on all managed nodes.www1.06.1c 7. HP Service Pack for ProLiant 2014. The SMH certificate can be found on each node of the data center as. For 7.3 are full builds that include an updated version of OpenSSL (1.hp. For details refer to Section 17 of SIM User guide for 7.3. cert.org/news/secadv_20140605.0 .0 Release Notes Fixes Patched to address SSL/TLS MITM Vulnerability CVE-2014-0224 (http://www. even if the corresponding service is stopped or disabled  For Windows:  Service name: SysMgmtHp and display name: HP System Management Homepage  For Linux:  Service name: hpsmhd SMH can be upgraded by following any of the below methods:  Direct upgrade on each individual nodes by following the upgrade steps documented in Installation guides. there are some steps to perform after you’ve upgraded to the nonvulnerable components. In case it is suspected that the infrastructure has been compromised.0. either of the following two methods can be used:  Using HP-SUM (more details in Section 5 of above mentioned SMH install guides)  Using HP-SIM (Refer to Section 3 of SIM user guide. recreating.3 http://h20564.hp. New certificates will be created when SMH service starts (at the end of the upgrade or new installation). only SMH needs to be upgraded.1h).pem & file.pem available inC:\hp\sslshare (on Windows) & /etc/opt/hp/sslshare (on Linux). not the complete SPP.3.3 (http://h20564.06.VCRM communication: The communication will be Impacted.3.3 o o o o o SMH versions 7.www2. If VCA use “Using Certificate” option to connect to VCRM and VCRM’s SMH is configured with “Trust by Certificate” option.openssl.06. 714 o Impact on VCA . the user needs to delete the SMH certificate (or take back-up by copying it to a private folder). When VCA’s SMH certificate is deleted & regenerated (as suggested before).3 installation refer to 7.www2. otherwise use Username/Password OR set either “Trust by HP | Service Pack for ProLiant 2014. The delete file command (for deleting certificates) can be centrally executed for multiple nodes. These steps include revoking. and re-importing certificates and resetting passwords that might have been harvested by a malicious attacker using the known vulnerability.com/portal/site/hpsc/public/kb/docDisplay/?docI d=c04030739 ) If you believe your SMH installation was exploited while it was running components vulnerable to CVEs reported against OpenSSL. For 7. to update on multiple nodes.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04030739). The table included below can be used to select the correct version to install.3. using SIM’s Custom Tool option.www2.txt) HP System Management Homepage for Windows x86 Version: 7.hp.3 installation and upgrade guide (http://h20564. To remove this vulnerability from SMH. new certificate needs to be (re)imported.1 (Critical) Important Note! Installation instructions for SMH 7. Users can safely upgrade to these versions of SMH.3.com/portal/site/hpsc/public/kb/docDisplay/?docId=c0403076 6)  From a central location. 0.2.3.3 openssl-1.0 Linux OS Windows (except Win2003 & 2003 R2) OS openssl-1.2 2012.3 7.0.3.2 7.3 7.0.02.0 (B) 7.3.0 7.3 openssl-1. New certificate will be created when SMH service starts (at the end of the fresh / upgrade installation). you will also need to revoke those SMH certificated from HPSIM and reimport the newly created SMH certificates.0 7.1c 7.1c 7.1.1c 7.1c 7.1e 7.3 openssl-1.0.2u2 2013.0 715 .0.02.06. What are the recommended upgrade paths? Recommended version of SMH for upgrade SMH DVD SPP OpenSSL 7.1e 7.3 openssl-1.3 openssl-1.3.06.0 2013. 4.0 (B) 7.3. Will new certificates be issued along with the patch.0 7.3. Though SMH uses OS credentials using OS-based APIs.3 7.0 7.2 7.www1. user provided credentials are passed from the client (browser) to the server (SMH) using the HTTPS protocol.1g 7. or SMH will reuse the existing certificate. 5.2 2014.3 7.2u1 7.com/us/en/enterprise/servers/solutions/info-library. these passwords need to be reset.3.0 Release Notes o o Name” or “Trust All” option in VCRM’s SMH to reestablish the connection.0. Select “HP Insight Management” under ‘Product and Solutions’ & check “HP System Management Homepage” to get SMH related documents.3.1g 7. or need to be handled separately? If you suspect the certificate has been compromised due to this vulnerability.HP Service Pack for ProLiant 2014. 3. o Is a FW Update necessary in addition to the SMH patch? No.2.3. If you use HPSIM’s “2-way trust” feature.3 HP | Service Pack for ProLiant 2014.3.10.0.3.3. only the SMH update is sufficient to remove the vulnerable version of SMH.09.3. If you suspect your systems using SMH were exploited while they were vulnerable.3 7.3. Installing the new build is sufficient to get back to the normal state. reboot of the system will not be required.3 openssl-1.0. Where can I get SMH documentation? All major documents are available at: http://h17007.3 7. and have imported SMH certificates into HPSIM.3.1 7.1.3.3 openssl-1.3.1 7. Will updated systems require a reboot after applying the SMH patch? No.hp. FAQs: 9.3. Instructions on deleting the certificate are in the notes above.3 7.2.1 7.3.3 7.2. we do recommend to delete and revoke the certificate.3.3.2.3 7. 1.0 716 .0.0 These three packages provide equivalent functionality as hpasm v8.1.1.txt) HP System Management Homepage Templates for Linux Version: 9. If VCA use “Using Certificate” option to connect to VCRM and VCRM’s SMH is configured with “Trust by Certificate” option.0. otherwise use Username/Password OR set either “Trust by Name” or “Trust All” option in VCRM’s SMH to reestablish the connection.5. When VCA’s SMH certificate is deleted & regenerated (as suggested before). Prerequisites To get the list of all dependency files for hp-smh-templates type: rpm –qp –-requires hp-smh-templates-<version>.0 HP SNMP Agents (hp-snmp-agents) version 8.06. 8.0 and allow for more modular installation choices.0 Release Notes 6.org/news/secadv_20140605.openssl. How can I verify whether my setup is patched successfully? SMH version can be verified by executing following command on: o o Windows: “hp\hpsmh\bin\smhlogreader –version” Linux: “/opt/hp/hpsmh/bin/smhlogreader –version” o Will VCA-VCRM communication be impacted due to the SMH certificate being deleted? The communication will be Impacted.rpm Enhancements Added support for: HP | Service Pack for ProLiant 2014. where SMH was/is running? Though SMH uses OS credentials using OS based APIs.0 HP System Management Homepage Templates (hp-smh-templates) version 8. Passwords need to be reset if you suspect the vulnerable version of SMH was exploited by malicious users/ hackers. user-provided credentials are passed from the client (browser) to the server (SMH) using the HTTPS protocol.0 was split into three individual rpm packages: o o o HP System Health Application and Command Line Utilities (hp-health) version 8.06. Should I reset password on all managed nodes.0 (Optional) Important Note! The HP System Health Application and Insight Management Agents (hpasm) version 8. new certificate needs to be (re)imported. Fixes Patched to address SSL/TLS MITM Vulnerability CVE-2014-0224 (http://www.HP Service Pack for ProLiant 2014. 0 .HP Service Pack for ProLiant 2014.0 Release Notes o o New HP ProLiant Gen8 Servers.06. IPv6 for iLO. 717 HP | Service Pack for ProLiant 2014.06.
Copyright © 2024 DOKUMEN.SITE Inc.