Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500Model EC-HS — 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers Installations per VdS CEA 4001, Annex E, LH/OH1 General Description The Model EC-HS, 80 K-factor, Extended Coverage Horizontal Sidewall Sprinklers are extended coverage, decorative 3 mm glass bulb type spray sprinklers. They are to be installed per VdS CEA 4001 under smooth ceilings in Light or Ordinary Hazard 1, as well as in accordance with Annex E of VdS CEA 4001 (e.g., commercial occupancies such as churches, restaurant seating areas, hotels, educational facilities, offices, etc.). With their coverage up to 21 m2, they are designed for installation along a wall or the side of a beam and just beneath a smooth and level ceiling. Horizontal sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The recessed version of the Model ECHS Extended Coverage Horizontal Sidewall Sprinkler utilizes the Style 10 Recessed Escutcheon with 13 mm of recessed adjustment or up to 19 mm of total adjustment from the flush sidewall position, or a two-piece Style 20 Recessed Escutcheon with 6 mm of recessed adjustment or up to 13 mm of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe lengths to the sprinklers must be cut. NOTICE The Model EC-HS Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards recognized bt the Approval agency (VdS recognizes VdS CEA 4001), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY3330 EC-HS, 80K, 1/2"NPT IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 MARCH, 2009 TFP288 . . . . . . FIGURE 1 MODEL EC-HS (TY3330) EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS 80 K-FACTOR. the fluid expands sufficiently to shatter the glass Bulb. . . .Deflector * 6* 5 2 3 WRENCH FLATS 1 1/2" ** NPT 12 mm 41 mm CENTERLINE OF SPRINKLER WATERWAY 11 mm NOMINAL MAKE-IN 38 mm Finishes Sprinkler: White.Frame 2 . . . . . . . Maximum Working Pressure 12 bar Discharge Coefficient K = 80 LPM/bar1/2 Temperature Ratings 57°C. and 79°C.Sealing Assembly 4 . . . . . . . STYLE 10 or 20 RECESSED ESCUTCHEON Operation The glass Bulb contains a fluid which expands when exposed to heat. Glass Compression Screw . . ESCUTCHEON PLATE SEATING SURFACE ** Pipe thread connections per ISO 7/1 may be provided on special request. . . . . .Button 3 .Compression Screw 6 . Bronze Button . .Bulb 5 . . 73 mm DIA. .Page 2 of 6 TFP288 DEFLECTOR HAT 4 Technical Data Approvals VdS Approved. . 68°C. . . Bronze 12 mm 56 mm * Temperature rating is indicated on top of deflector or adjacent to orifice seat on frame. . . or Brass Plated. Brass/Copper Sealing Assembly . . Chrome Plated. . . . . . . or Brass Plated. * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. . Bronze Deflector . 1/2 INCH NPT † DuPont Registered Trademark . . allowing the sprinkler to activate and water to flow. . . Response Sensitivity Quick respose. . . . . Chrome Plated. . When the rated temperature is reached. . . Beryllium Nickel w/Teflon† Bulb . . Recessed Escutcheon: White. . . . . RTI less than 50 TOP Components: 1 . Physical Characteristics Frame . . 8 m room height • 3. Netherlands. * Installed with Style 10 Recessed Escutcheon (Figure 4).5 m Sprinkler Spacing Along Wall (Sprinkler Coverage Width) 3.TFP288 Page 3 of 6 SPRINKLER FINISH K TYPE TEMP.0 m to 4. Maximum Sprinkler Coverage Area 21 m2 (separated with F30 fire resistance in accordance to DIN4102 Maximum Ceiling Height 4.0 bar for equal to and greater than 2. Only the Style 10 or 20 Recessed Escutcheon. as well as in accordance with Annex E of VdS CEA 4001. as applicable. BULB LIQUID Orange Red Yellow Orange Red Yellow Orange Red Yellow 1 1 1 NATURAL BRASS CHROME PLATED WHITE*** POLYESTER Design Criteria The Model EC-HS Extended Coverage Horizontal Sidewall Sprinklers are to be installed per VdS CEA 4001 under smooth ceilings in Light or Ordinary Hazard 1. Refer to VdS CEA 4001 for complete installation rules. ** Installed with Style 20 Recessed Escutcheon (Figure 5).1 m Maximum Room Depth • one sprinkler line: 6. is to be used for recessed installations.10 m to 0. Enchede. LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) WRENCH RECESS Maximum Coverage Width 4.5 m WRENCH RECESS (END "A" USED FOR MODEL EC-HS) FIGURE 2 W-TYPE 6 SPRINKLER WRENCH PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA Maximum Sprinkler Deflector to Wall Distance 0.8 m room height FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH . Tel. 31-53-428-4444/Fax 31-53-428-3377). VdS Approved (For details contact Tyco Fire Suppression & Building Products.25 m Minimum Discharge Pressure • 2. The following design criteria is provided as a general guide.5 bar for less than 2.5 m Minimum Sprinkler to Room Corner Distance 0.5 m • two opposite sprinkler lines: 11 m 80 1/2" NPT 80 1/2" NPT 80 1/2" NPT EC-HS (TY3330) 57°C 68°C 79°C RECESSED EC-HS* (TY3330) RECESSED EC-HS** (TY3330) 57°C 68°C 79°C 57°C 68°C 79°C NOTES: 1. TABLE A.3 m Deflector-to-Ceiling Distance 0. The word “TOP” on the deflector is to face towards the ceiling. The word “TOP” on the deflector is to face towards the ceiling.Page 4 of 6 TFP288 16±6 mm MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTING SURFACE 13±3 mm FACE OF SPRINKLER FITTING CLOSURE 73 mm DIA. 57 mm DIA. Step D. a small air bubble should be present. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Figure 3). hand tighten the sprinkler into the sprinkler fitting. The Model EC-HS Recessed Sidewall Sprinklers must be installed in accordance with the following instructions. 1/2 INCH NPT Installation The Model EC-HS Sprinklers must be installed in accordance with the following instructions: The Series Model EC-HS Sidewall Sprinklers must be installed in accordance with the following instructions. CLOSURE 73 mm DIA. the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. 1/2 INCH NPT FIGURE 5 MODEL EC-HS RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 13MM TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 80 K-FACTOR. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref.6 mm. After installing the Style 10. the WType 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats.5 to 19. 57 mm DIA. Horizontal sidewall sprinklers are to be installed with their centerline perpendicular to the back wall and parallel to the ceiling. .0 Nm. slide on the Style 10 or 20 Closure over the Model EC-HS Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. The diameter of the air bubble is approximately 1. hand tighten the sprinkler into the sprinkler fitting. Step 2. NOTICE Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. or 20 Mounting Plate. over the sprinkler threads and with pipe thread sealant applied to the pipe threads. After the wall has been installed or the finish coat has been applied. Step 3. Step A. With pipe thread sealant applied to the pipe threads. Readjust the position of the sprinkler fitting to suit. MODEL EC-HS MODEL EC-HS MOUNTING PLATE 3 mm 32 mm 19 mm 19 mm 6 mm MOUNTING PLATE 3 mm 32 mm 25 mm 13 mm 6 mm FIGURE 4 MODEL EC-HS RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 19 MM TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 80 K-FACTOR. Step C. With the sprinkler held horizontally. A 1/2 inch NPT sprinkler joint should be obtained with a minimumto maximum torque of 9. Figure 2). With reference to Figure 1. as applicable. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Step B.or over-tightening the sprinkler. Step 1. Horizontal sidewall sprinklers are to be installed with their centerline perpendicular to the back wall and parallel to the ceiling. Do not attempt to make-up for insufficient adjustment in the escutcheon plate by under. With reference to Figures 1. special or consequential damages. as well as the standards of any other Authorities Having Jurisdiction. improper installation. Sprinklers that have been exposed to corrosive products of combustion. Sprinklers damaged by dropping. of any portion of this warranty will not affect the remainder. The foregoing warranty is made in lieu of any and all other warranties. express or implied. The invalidity. (Ref. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. wrench twist/slippage. and maintenance of their fire protection system and devices in compliance with this document. testing. plated. Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. corrosion. including but not limited to labor charges. The owner is responsible for the inspection.before. including warranties of merchantability and fitness for a particular purpose. otherwise. non-operation in the event of a fire or inadvertent operation may result. replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. and maintained by a qualified Inspection Service in accordance with . for incidental. materials or components. modified or repaired in accordance with the standards recognized by the Approval agency. and in no event shall TFSBP’s liability exceed an amount equal to the sales price. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. No warranty is given for products or components manufactured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse. Automatic sprinklers must never be painted. should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. tested. and after installation. tort. but have not operated. The owner must assure that the sprinklers are not used for hanging of any objects. strict liability or under any other legal theory. as well as with the applicable standards of the authorities having jurisdiction. This warranty will apply to the full extent permitted by law. regardless of whether TFSBP was informed about the possibility of such damages. at TFSBP’s sole option. In no event shall TFSBP be liable. Materials found by TFSBP to be defective shall be either repaired or replaced. Also. or which have not been installed. striking. indirect. may delay the time to sprinkler operation in a fire situation. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls. or the like. strict liability or any other legal theory.TFP288 Page 5 of 6 Care and Maintenance The Model EC-HS Sprinklers must be maintained and serviced in accordance with the following instructions: local requirements and/or national codes. Modified sprinklers must be replaced. coated or otherwise altered after leaving the factory. Care must be exercised to avoid damage to the sprinklers . This warranty will expire ten (10) years from date of shipment by TFSBP. must be replaced. during. maintained. nor authorizes any person to assume for it. It is recommended that automatic sprinkler systems be inspected. Installation Section). which is used to cover a clearance hole. any other obligation in connection with the sale of products or parts of products. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products. in contract. tort. whether the claim is made in contract. in whole or part. Absence of an escutcheon. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. TFSBP neither assumes. Lansdale. 80 K-factor. Contact your local distributor for availability. Pennsylvania 19446 . (specify temperature rating). P/N 56-850-4-001. Specify: W-Type 7 Recessed Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. 451 North Cannon Avenue. Recessed Escutcheon: Specify: Style (10 or 20) Recessed Escutcheon with (specify) finish. * Refer to Technical Data Sheet TFP770.Page 6 of 6 TFP288 57 — 367 — X — XXX TEMPERATURE RATING SPRINKLER 135 1 3 9 NATURAL BRASS WHITE (RAL 9010) CHROME PLATED 155 175 57°C 68°C 79°C TABLE E PART NUMBER SELECTION SERIES EC-HS EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS Ordering Procedure When placing an order. P/N (specify*). P/N (specify from Table B). P/N 56-000-6-387. © 2009 TYCO FIRE SUPPRESSION & BUILDING PRODUCTS. indicate the full product name. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench. Model EC-HS Extended Coverage Horizontal Sidewall Sprinkler with (specify type of finish or coating). Sprinkler Assemblies with NPT Thread Connections: Specify: SIN TY3330.
Report "SPK DE PERETE.pdf"
×
Please fill this form, we will try to respond as soon as possible.
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
Copyright © 2024 DOKUMEN.SITE Inc.