BC80 CatalogueType Description/Technical Data Stock Code Picture Page c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 1 BC80 Catalogue Type Description/Technical Data Stock Code Picture c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice TableBC80 Catalogue of Contents Type Description/Technical Data Stock Code Picture Page 1. BC8001 Series Fire Alarm Control Unit.....................................2 BC8001 Compact Control Unit with 1 line (127 Dev) ..................................2 BC8001P Compact Control Unit with 1 line, printer ..........................2 BC8001E Compact Control Unit with 2 line (254 Dev).......................3 BC8001PE Compact Control Unit with 2 line, printer.........................3 2. BDS Series Field Device.............................................................4 BDS051 Optical Smoke Detector.......................................................4 BDS031 Heat Detector (Rate of Rise and Fixed)...............................4 BDS000 Addressable Detector Base.........................................................4 OP520 Collective Optical Smoke Detector.........................................5 HI520 Collective Heat Detector (Rate of Rise and Fixed)..................5 SO520 Collective Detector Base........................................................5 BDS121 Manual Call Point.................................................................6 BDS132 Input Module........................................................................6 BDS221 Output Module......................................................................7 BDS331 Fire Alarm Display Panel......................................................7 BDS161 Collective Input Module........................................................8 BDS152 Isolation Module...................................................................9 3. BC80 Panels and Function Cards.............................................10 BC8013H Wall Mounted Extinguishing Panel...................................10 BCE8001 Extension Card.................................................................11 BC8001 Compact CPU Board...........................................................11 BC8001 Compact Main Board..........................................................11 TP8000 Printer................................................................................12 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 1 BC80 Catalogue Type Description/Technical Data Stock Code Picture BC8001 Series Fire Alarm Control Unit BC8001/e BC8001 Compact Control Unit with 1 line(127 Dev) BC8001 is a control unit very suitable for small size projects and constructions. It has the following features: BDS series field devices compatible. 2 Wires and polarity free F-BUS, transmission distance is up to 1000m. Specialized BDS algorithm enhance immunity to environment disturbances. Menu driven person-machine interface, very easy to operate. With optional extension card can be networked up to 31 other BC80 control units(BC8001/BC8002/BC8004). With optional extension card, possible to connect up to 3 B-Bus equipment like interlocking and extinguishing panels. Optional printer can be mounted in to the control unit. System can be easily configured on the panel or via PC. Configuration data can be uploaded to PC at any time. A6C50000016 Number of Detector Lines Number of Field Devices System Network Built-in Printer LCD Display Auto Mapping Event History Digital I/O's - Nr. Of Dry contacts(24V/3A) - Nr. Of OC outputs - Nr. Of Monitored inputs Operating Voltage Battery-Backup Download/Upload Dimension Weight(Without Batteries) 1 127 240 x 128, Backlit Yes 1000 1 1 2 100 ~ 240VAC, 50 ~ 60Hz 24V, 6.5Ah USB 370 x 265 x 120mm 3.0kg BC8001P/e BC8001P Compact Control Unit with 1 line, printer One printer (TP8000 thermal sensitive printer) is built in with the features above. A6C50000018 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 2 BC80 Catalogue Type Description/Technical Data Stock Code Picture BC8001E/e BC8001E Compact Control Unit with 2 line (254 Dev) An extension card is built-in additionally in the BC8001 which can Interconnect via A-Bus up to 31 controllers (BC8001/BC8002/BC8004 Control Unit). Interconnect up to 3 B-BUS equipments(BT8011/12 interlocking panel, BC8013 extinguishing panel). A6C50000017 BC8001PE/e BC8001PE Compact Control Unit with 2 line, printer Same as BC8001, printer and extension card are built in additionally. A6C50000019 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 3 BC80 Catalogue Type Description/Technical Data Stock Code Picture BDS Series Field Devices BDS051 BDS051 Optical Smoke Detector The BDS051 is smoke detector which can be connected via F-Bus to BC80 series control unit. Patented labyrinth optical structure. New built-in ASIC ensures the high reliability of data processing. Homogeneous response to different smoke. High stability against dust, electromagnetic interference, temperature fluctuation, humidity and corrosion. Produced with SMT advanced technology. Operating Voltage Operating Temperature Storage Temperature Relative Humidity Quiescent Current Alarm Current EMC 16 ~ 32V DC -10 ~ +50℃ -25 ~ +75℃ ≤ 95%(40 ± 2℃) ≤ 1.0mA ≤ 3.0mA 10V/m A6C50000002 BDS031 BDS031 Heat Detector (Rate of Rise and Fixed) Newly developed circuit and sensor ensure high performance of fixed and rate-of-rise temperature detection. High stability against dust, electromagnetic interference, temperature fluctuation, humidity and corrosion. Produced with SMT advanced technology. Operating Voltage Operating Temperature Storage Temperature Relative Humidity Quiescent Current Alarm Current EMC 16 ~ 32V DC -10 ~ +50℃ -25 ~ +75℃ ≤ 95%(40 ± 2℃) ≤ 1.0mA ≤ 3.0mA 10V/m A6C50000001 BDS000 BDS000 Detector Base The detector base is for mounting the field devices BDS051 and BDS031. The detector covers the whole base, the wiring capacity is 1.0 to 1.5 mm2 . A6C50000000 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 4 BC80 Catalogue Type Description/Technical Data Stock Code Picture BDS Series Field Devices OP520 OP520 Collective Optical Smoke Detector The OP520 is an colletive detector can be connected in to S11 system and BC80 system via corresponding collective input modules. Patented optical structure and labyrinth. Homogeneous sensitivity to different smokes. High stability against dust, electromagnetic interference, temperature fluctuation, humidity and corrosion. Manufactured by advanced SMT technology. Polarity detection and wrong connection fault-free. Operating Voltage Output Voltage Quiescent Current Operating Temperature Storage Temperature Working Humidity EMC Alarm Indicator Current 21~ 29V DC 5 ~ 13V ≤ 100 uA -10 ~ +50℃ -30 ~ +75℃ ≤ 95%(40 ± 2℃) 10V/m 1.5mA A6C50000010 HI520 HI520 Collective Heat Detector (Rate- of- Rise and Fixed) Newly developed circuit and sensor ensure high performance of fixed and rate of rise temperature detection. High stability against dust, electromagnetic interference, temperature fluctuation, humidity and corrosion. Produced with SMT advanced technology. Operating Voltage Output Voltage Operating Temperature Storage Temperature Relative Humidity Quiescent Current Alarm Current EMC 21 ~ 29V DC 5 ~ 13V -10 ~ +50℃ -30 ~ +75℃ ≤ 95%(40 ± 2℃) ≤ 100 uA ≤ 1.5 mA 10V/m A6C50000009 SO520 SO520 Collective Detector Base The detector base is for mounting the field devices HI520 and OP520. A6C50000011 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 5 BC80 Catalogue Type Description/Technical Data Stock Code Picture BDS Series Field Devices BDS121/e BDS121 Manual Call Point Manual call point can immediate trigger a fire alarm by breaking the glass. Direct connected on the BDS F-Bus, P,S polarity free. Installed in the public area such as staircase, elevator lobby. Address can be set via Dip-switch. A built-in dry contact can be used for activating other equipment. Mounted on the wall 1.5 meters above the ground. Delivered electronic part and housing separately. Operating Voltage Quiescent Current Alarm Current Working Temperature Working Humidity 24VDC ≤ 1mA ≤ 3mA -20 ~ +55℃ ≤ 95%(40 ± 2℃) A6C50000003 Capacity of the dry contact 24VDC/ 0.1A EMC 10V/m BDS132/e BDS132 Input Module The input module can be a interface to transmit the alarm or technical signal from other equipment to Fire Alarm Control Unit. Connect on the BDS F-Bus directly, address can be set by a built-in Dip-switch. Be used for interfacing the signals from flow switch, pressure switch, etc and other parties to the fire alarm system. Input signal has to be a potential free digital signal. The signal will be transmitted to controller and trigger corresponding activations by preset logic expressions. Fault will be automatic detected and displayed on the controller. A6C50000004 Operating Voltage Quiescent Current Activation Current Working Temperature Relative Humidity Wiring Capacity 24VDC ≤ 1mA ≤ 3mA -10 ~ +50℃ ≤ 95% (40 ± 2℃) 1.0 ~ 1.5mm2 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 6 BC80 Catalogue Type Description/Technical Data Stock Code Picture BDS Series Field Devices BDS221/e BDS221 Output Module The output module is to activate external equipments according to the preset logic expressions and also expecting to receive a confirmation of activation. Connect on the F-Bus directly, address set via Dip-switch. Can activate external devices by preset logic, the output can be a pulse or steady signal according to Dip-switch set up. On the BDS detection line P , S can be connected with polarity free. The input signal is a potential free contact. Can be used for activating high voltage devices via connecting ZA2225 and ZA2226 in between. It is not recommended to use this module for extinguishing control directly. Fault will be automatic detected and displayed on the controller. Operating Voltage Quiescent Current Activation Current Working Temperature Relative Humidity Capacity of the output relay Confirmation LED Pulse Output 24VDC ≤ 1mA ≤ 3mA -10 ~ +50℃ ≤ 95% (40 ± 2℃) AC125V/0.6A, DC24V/2A Steady output Steady ON Flashing A6C50000007 BDS331/e BDS331 Fire Alarm Display Panel The panel is used for display alarm event on the floor. 1 BDS331 can display information of the devices on the same F-BUS. Up to 127 devices can be displayed. Can display fire alarm and control information. The numbers of devices can be displayed on the LED display. Fault will be automatic detected and displayed on the controller. An relay output is built-in. Additional power supply by 24-28VDC, is necessary. Operating Voltage Monitoring Current Alarm Current Working Temperature Working Humidity Relay Output 24VDC ≤ 6mA ≤ 60mA -10 ~ +50℃ ≤ 95% (40 ± 2℃) 125VAC/1A, 24VDC/1.25A A6C50000008 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 7 BC80 Catalogue Type Description/Technical Data Stock Code Picture BDS Series Field Devices BDS161/e BDS161 Collective Input Module This collective input module can connect collective detectors to the F-Bus. Directly connected on the F-Bus, address can be set by Dip-switch, and the other 2 wires connect the collective detectors. Can be connected only in BC80 system. One BDS161 can connect up to 25 collective detectors, with the end of line element P6KE18CA. Can transmit alarm, fault, normal danger level signal to control unit and has also indication on the module. On the BDS detection line P, S can be connected with polarity free. Collective detector's terminal "1,2 and 3,4 "connected to BDS161 "D+ and D _ "correspondingly. Alarm Indicator AI340 and AI300 can be connected on "L+, L_ ". Fault will be automatic detected and displayed on the controller. Alarm Voltage Fault Voltage(Short) Fault Voltage(open) Normal Voltage Quiescent Current Alarm Current Operating Voltage Working Temperature Alarm Indicator Wiring Capacity 3.7V ~ 16.4VDC 0V ~ 3.7VDC 22.1VDC 16.4V ~ 22.1VDC < 4mA < 16mA -10 ~ +50℃ ≤ 95% (40 ± 2℃) 1.5mA 1.0 ~ 1.5mm2 A6C50000006 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 8 BC80 Catalogue Type Description/Technical Data Stock Code Picture BDS Series Field Devices BDS152/e BDS152 Isolation Module The isolation module is used for isolating the short point on the detection bus so that the devices which are connected to the controller before the short point will not be influenced. It will automatically recover to its normal status when the fault is eliminated. In case the short happens on the detection bus, the isolation module activates so that the devices before the short point can work normally. Parallel connection on the first place of each branch or stub. No need to set address. When one loop monitors several floors, on each floor one Isolation module shall be installed. One isolation module can connect up to 25 field devices. P0, S0 on BDS152 connect to control unit P,S terminal with polarity sensitive. The P,S terminal on BDS152 can connect to the P,S of other field devices with polarity free. Fault will be automatic detected and displayed on the controller. Working Temperature Working Humidity Activation Current Pass through Voltage Wiring Capacity -20 ~ +50℃ ≤ 95% (40 ± 2℃) ≤ 0.5mA ≤ 1V 1.0 ~ 1.5mm2 A6C50000005 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 9 BC80 Catalogue Type Description/Technical Data Stock Code Picture BC80 Panels and Function Cards BC8013H/e BC8013H Wall Mounted Extinguishing Panel The extinguishing panel is used for controls of extinguishing section. One panel monitors 2 extinguishing section, for each section 3 outputs and 3 confirmation signals for those outputs are equipped for activation of extinguishing alert, extinguishing section separation, gas release. Can be connected via B-Bus, address set by Dip-switch, Information of extinguishing section can be displayed on the control unit. Parameters can be configured on panel and via PC-Tool. Can operate the controlled section on site or on the panel. External control wires are monitored automatically against the short. Panel can be set in automatic mode and manual mode. Auto mapping is possible. Fault is automatically detected and displayed on the panel. Operating Voltage Quiescent Current Operating Current Nominal Output Current Maximum Current per output Working Temperature DC24V ~ 28V 40.0mA 200 mA 80mA 200mA -20℃ ~ 40℃ A6C50000022 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 10 BC80 Catalogue Type Description/Technical Data Stock Code Picture BC80 Panels and Function Cards BCE8001 BCE8001 Extension Card It is the extension card for the BC8001 compact controller. A-Bus interface can make the compact controller networkable to 31 controllers. B-Bus interface can make the controller connect up to 3 B-Bus equipments. F-Bus interface can connect one detection bus additionally which can connect up to 127 devices more. A6C50000024 BCC8010 BC8001 Compact CPU Board Function of the CPU board is storing, loading the configuration data. 80040600 BCC8001 BC8001 Compact Main Board Function of the main board is to handle the data and event received from field. 80010100 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 11 BC80 Catalogue Type Description/Technical Data Stock Code Picture BC80 Panels and Function Cards TP8000 TP8000 Printer A thermal sensitive printer can print out the event on the logger paper when event occurs. A6C50000028 c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice 12 BC80 Catalogue Type Description/Technical Data Stock Code Picture c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice BC80 Catalogue Type Description/Technical Data Stock Code Picture c 2005 Beijing Siemens Cerberus Electronics LTD. - Data subject to change without notice