Flameproof DC motors for hazardous locationsC Series – DC motors Grandezze-Sizes 7 ÷ 23 Catalogo – Catalogue Code C-DC-ATEX-7-23-E-11 . +390114076311 . steams. B -20°C . batteries.sicmemotori.com – sicmemotori@sicmemotori. viewed from DE Options available Thermoprotectors (NC contact) PTC thermal protector Pt100 thermistors Tachometer (explosion-proof type) Pulse generator (explosion-proof type) Anticondensation heater (excluding frame C7) Tropicalization of windings Brush wear control device (excluding frame 7) Bearings and lubrication data Bearing type Frame size C7/C7C C11 C13 C16 C19/C19H C23 Drive End Non-Drive End Grease type 6204-2Z-C3 6205-2Z-C3 6307-2Z-C3 6308-2Z-C3 6310-2Z-C3 NU313-C3 6203-2Z-C3 6205-2Z-C3 6306-2Z-C3 6307-2Z-C3 6308-2Z-C3 6310-2Z-C3 Lithium grade III Bearing lubrication Grease q. chopper Class H Class H. page 2 of 12 . frame externally cooled) IP55 (IEC 34-5) according to IEC 34-7 at left side. skin temperature Balancing Type of cooling Degree of protection Mounting Main terminal box : : : : : : : IEC 60034 3-phase.+40°C Minimum stocking temperature: -40°C Maximum working temperature (with derating): 60°C 1000masl max (up to 4000masl with derating) +200°C (class of di tempera ture T3) class G2. F. smokes) • Execution : EX d II B with class of temperature T3 for duty from S1 to S9 • Degree of protection : IP55 (according to IEC 34-5) Motor design Standards Supply Insulation Temperature rise Ambient temperature : : : : : Altitude of installation Max.5 (ISO 2373) IC411 ( IEC 34-6: self ventilated totally enclosed motor. Ward-Leonard group. 1-phase.com .ty (g) Bearing re-greasing intervals (h) DE NDE DE NDE Greased for life 30 20 Greased for life 6500 7000 Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel. The motors are certified by CESI (Centro Elettrotecnico Sperimentale Italiano ) according to the Directive 94/9/CE (ATEX) for the following execution: • Group : II (not mine) • Category : 2 (high protection) • Type of explosive atmosphere : G (gas.Fax +390114500047 – www.C Series FLAMEPROOF DC Motors (ATEX) General Flameproof DC motors C Series had been expressly designed for a fully reliable operation and in conformity of safety prescriptions as requested by the regulation in force for electrical installations in dangerous environments. 2 x 42W No.2kW 3600rpm B or F 2.5 From NPT1 ½ to NPT 2 ½ From M25x1.4kW 3000rpm B or F 6x2. steams.5 to M75x1.5 to M50x1.5 From NPT 1 ½ to NPT 2 ½ M25x1.5 to M50x1.5 to M75x1.Fax +390114500047 – www.5 From NPT 1 to NPT 2 From M20x1.com – sicmemotori@sicmemotori. thermistors) Nr.sicmemotori.C Series FLAMEPROOF DC Motors (ATEX) CESI Certificates Frame size C7 C 7C C 11 C 13 C 16 C 19 C 19H C 23 Execution + Class of Temperature II 2G Exd IIB T3 II 2G Exd IIC T3 II 2G Exd IIB T3 II 2G Exd IIB T3 II 2G Exd IIB T3 II 2G Exd IIB T3 II 2G Exd IIB+H2 T3 II 2G Exd IIB T3 Motor Certificate No. smokes) C13 C16 Exd IIB Exd IIB T3 T3 IC411 IC411 CVEd CVEd 55 56 -20 °C -20 °C +60°C +60°C 500VDC 500VDC T3 IC411 CVEd 55 -20 °C +60°C 440VDC C11 Exd IIB T3 IC411 CVEd 55 -20 °C +60°C 500VDC 18ADC 49ADC 49ADC 15. 1 x 42W No. and theoretical section supply cables into the terminal box C7 Exd IIB C7C EXd IIC II (not mines) 2 (high protection) G (gas. Extension Certificate CESI 03 – ATEX 322 CESI 03 – ATEX 322 CESI 03 – ATEX 045 CESI 03 – ATEX 045 CESI 03 – ATEX 045 CESI 03 – ATEX 306 CESI 03 – ATEX 306 CESI 03 – ATEX 045 01/08 01/08 01/08 01/08 01/08 02/08 02/08 01/08 General prospectus for C Series motors according to ATEX Std (CEI EN 60079-0:2006/07 and CEI EN 60079-1:2005/11) Group Category Type of atmosphere Motor type Execution Class of surface temperature Cooling type (IEC) Cooling type (SICMEMOTORI code) Degree of protection (IEC) Minimum working temperature Maximum working temperature Maximum armature voltage Maximum armature current (up to 40°C ambient temperature) Maximum armature current (for 60°C ambient temperature) Maximum motor power Maximum motor speed Temperature rise class Nr.5 to M33x1.5mm2 T3 IC411 CVEd 56 -20 °C +60°C 750 DC C23 Exd IIB T3 IC411 CVEd 55 -20 °C +60°C 500VDC 86ADC 155ADC 200ADC 43ADC 76ADC 135ADC 175ADC 6kW 3000rpm B or F 14kW 3600rpm B or F 25kW 3200rpm B or F 35kW 2500rpm B or F 6x25mm2 C19 Exd IIB C19H Exd IIB+H2 6x50mm2 50x32 6 leds M4 70x45 6 leds M6 115x70 6 leds M10 NPT ½ From M16x1. +390114076311 . 1 x 99W Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel.5 3x35mm2 + ground 3x70mm2 + ground N/A 2 3x6mm + ground Anticondensation heaters Frame size C7 C11 C13 up to C19 C23 Absorbed power N/A No.com . and max section of cables from armature to terminal board Terminal board installed into the terminal box Terminal box entry cable Auxiliary terminal box entry cable (for heaters.5 From M20x1.5 From NPT 1 to NPT 2 From M20x1.5ADC 43ADC 1. page 3 of 12 . 2 5 6 8.72 0.5 Power in kW Constant torque and/or constant power speed regulation Constant torque speed regulation below nominal speed is possible in the ratio 1:2 (for duty S1).72 0.12 0.3 0.2 0.8 9. This ratio can be increased up to 1:4 for application when load resistant torque is not constant when speed reduces (this is the case.2 2.16 0.53 0.5 1.5 1.2 5 5.2 5.8 7 8.3 10 12 15 19.7 8.com – [email protected] 12 14.2 0.5 2.5 3 5.5 2500 0.5 14 16 18.6 8.C Series FLAMEPROOF DC Motors (ATEX) Output data Motor selection for Three-phase fully controlled bridge supply ( by Single phase half controller bridge for (*)) Frame size C7S* C7M* C7L* C 11 S C 11 M C 11 L C 13 S C 13 M C 13 L C 16 S C 16 M C 16 L C 19 S / HS C 19 M / HM C 19 L / HL C 23 S C 23 M C 23 L 1000 0.3 1 1.64 2 2.25 0.45 0.5 19 23.8 4.5 4.3 3 3.2 7.3 5.1 1.2 0.7 10.7 3.5 6.8 7 8.7 7.9 2.9 1.35 0.8 5. of centrifugal machines such as some pump and fan).9 2.16 0.75 2.3 10 12 15 1200 0.6 6.5 10.47 1.sicmemotori.5 28.5 5.4 4.56 0.3 2. +390114076311 .4 4.5 Speed (rpm) 1800 0.9 1.12 0.1 1.4 4.8 3. For higher ratio please ask SICMEMOTORI. Constant power speed regulation above nominal speed (by reducing the field current at constant armature voltage) is possible up to 120% of nominal speed For higher values please ask SICMEMOTORI Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel.5 6.5 4.5 12 3600 0.42 0.4 10 12 15.5 28 33 35 3000 0.25 0.2 2.5 11.2 2.37 0.16 0.Fax +390114500047 – www.1 0.9 1.9 2. for example.5 1500 0.com .5 20 24.25 1.3 9.2 6.6 1. page 4 of 12 .8 3. 4 30.4 85 91 Notes: N/A: Not Available Voltage acceptable tolerance +/-10% Tolerance on speed as per EN60034-1 ($): This motor is certified IIC Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel.2 78.8 15.35 5. +390114076311 .5 81 80 82 86 76 80 80.3 14.9 2 2.7 15.6 6 7.5 40.7 82 83 Motor selection for 125Vdc supply voltage by battery Frame Size C 7L C 11S C 11M C 11L C 13S C 13M C 13L C 16S C16M C16L C19S C19M C 19L C 23S C 23M C 23L Power output (kW) Vs.3 34.85 2.8 8.1 2.8 8.4 12.1 5.75 5 6.2 101 112 144 158 Nominal torque (Nm) 2.5 8.8 20.1 51.8 10 11 14.15 1.sicmemotori.5 1.45 1.6 81.3 2.5 58.05 2.5 7.7 79.7 12.4 17 Absorbed current at 40°C (A) 6.56 1.2 69 75 90.6 4.8 11 10.15 1.6 3.4 1.9 4.3 76.6 Absorbed current at 40°C (A) 6.5 18.9 19. page 5 of 12 .8 0.48 1.1 14.1 1.2 0.1 4.3 5.1 2.4 69.9 52.3 36.8 2 2.9 17.6 58.2 92.25 1.8 13.5 6.2 10.7 3.2 15.7 1. rpm C 7CL 1770 N/A C 19HS C 19HM C 19HL N/A 1870 at 40°C at 45°C at 50°C 0.9 12.35 1.5 30 45 58 69 75 90 101 113 144 158 Nominal torque at 40°C (Nm) 3.5 25.8 6.52 1.05 2. ambient temp.1 32.4 6.5 15.9 16 19.5 9.8 9.1 12.5 3.63 1.5 9.8 15.8 1.2 8.59 1.9 7.2 7.9 46.5 3.5 1.95 2.9 11.8 7.8 46.6 0.9 6.55 1.2 1.9 12.7 78.4 27.2 0.2 78 78.9 Efficiency at full load at 40°C (%) 69 75.2 7.6 Efficiency at full load (%) 65 78.8 9.1 20.8 9.7 14.4 30 44.2 6.4 3 4.06 1.C Series FLAMEPROOF DC Motors (ATEX) Output data Motor selection for 110Vdc supply voltage by battery Frame Size C 7L C 11S C 11M C 11L C 13S C 13M C 13L C 16S C16M C16L C19S C19M C 19L C 23S C 23M C 23L C 7CL 1730 N/A C 19HS C 19HM C 19HL Power output (kW) Vs.3 11.6 38.9 5.2 9.9 8.2 80 83 78.6 75 74 78 80 84 74.2 21. ambient temp.com .2 9.2 21.6 10.9 2.6 2 2.25 7 8. rpm 1820 N/A at 40°C at 45°C at 50°C 0.com – [email protected] 82 77 79.5 25.8 7 6.75 1.3 6 7.Fax +390114500047 – www. 95+0.20+0.com – [email protected] 178 80 IP55 N/A 0.237 0.95 0.16+0.25 0.18+0.3 1.22 0.5 0.58 265 80 IP56 N/A 0.31+0.28+0.16 0.15 0.4+0. a 2-steps starting resistance must be connected in series with the armature circuit.22+0. Resist.5 230 80 IP56 N/A 0.1 0.1 1.48 0. a scheme of motor starting with connecting-disconnecting 2-steps starting resistance is given below.96+0.33+0.15 Degree of protection ATEX ATEX IIB IIB + H2 or IIC Armat.05+1.16+0.Fax +390114500047 – www.8+0.1+1.37 0.28 0.90 0.C Series FLAMEPROOF DC Motors (ATEX) Direct starting C Series DC motors are not suitable for direct starting.6 1.36+0.21 0.27 0.96 0.0 0.24 0.14 0.0+1.021 2.37+0.35 0.085 122 80 IP55 N/A 0.15 0.80+0.20 0.96 0.9 0.30+0.5+0.30 0.35+0.20+0.65+1.70+0.4+1.209 0.14+0. Temp.75 0.87+0.24+0.29 0.1 130 80 IP55 N/A 0.23+0.55 0.2 1.96+0.39 0.80 0.21+0.45+0.2 1. As an example.25 1.sicmemotori.87 0.26 0.18+0.23 0.1 395 80 IP56 IP55 0.45 0.5 1.76+0.4+1.26+0.34 0.16 0.42 0.2 1.2+2.75+0.13 3+3 2.1 1.5 0.45 210 80 IP56 N/A 0.15+0.22+0. In case of battery fed motors.32 0.02 1.5+1.05 0.76 0. +390114076311 .011 3. 110Vdc 125Vdc 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 50°C 40°C 2. Values of starting resistances are given in the table below (general information) DC motor with compound excitation Clockwise direction of rotation Counter-clockwise direction of rotation R1-R2 : starting resistances A1-A2 : armature winding B1-B2 : commutating winding (inside the motor) F1-F2 : field winding D1-D2 : stabilizing series General information Starting resistances (Ω) Item Frame size 1 C 7L C 7CL 2 C 11S 3 C 11M 4 C 11L 5 C 13S 6 C 13M 7 C 13L 8 C 16S 9 C 16M 10 C 16L 11 12 13 C 19S C 19HS C 19M C19HM C 19L C 19HL 14 C 23S 15 C 23M 16 C 23L Note Amb. page 6 of 12 .27+0.9 635 80 IP55 N/A 0.1+1.42+0.13+0.4 675 80 IP55 N/A Weight Tolerance +3 –0 dB(A) Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel.55+0.2+1.25+1.4 1.48+0.1 1.com .23 0.33 0.3+1.54 0. in order to reduce the starting current values within acceptable limits.65 1.043 1 370 80 IP56 IP55 0.3 420 80 IP56 IP55 0.65+0.18 0.8 0.015 55 80 IP55 IP55 0.013 2.23+0.65 0.18 0.5+2.6+2.32+0.2+1.4 1.90+0.29+0.6 580 80 IP55 N/A 0.21 170 80 IP55 N/A 0.059 0.3 188 80 IP55 N/A 0.5 2.15+0.03 1.04 0. The starting resistance must be connected during the motor starting operation only.34+0.22 0.20 0.70 0.17 0. (Ω) Rotor PD2 (kgm2) (kg) Noise level at 1m (dBA) 2.31 0.4 0.36 0.25+0. and it must be disconnected once the starting occurred.075 116 80 IP55 N/A 0.17+0.1+1. page 7 of 12 .com .com – sicmemotori@sicmemotori. +390114076311 .C Series FLAMEPROOF DC Motors (ATEX) Dimensions – Foot mounted motor – Horizontal B3 (IM1001) or V5 (IM1011) MAIN TB AUX TB AUX TB MAIN TB SHAFT SECTION AUX TB POSITION FOR C11 to C19 (if requested by purchase order) AUX TB POSITION FOR C23 (if requested by purchase order) Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel.sicmemotori.Fax +390114500047 – www. C Series FLAMEPROOF DC Motors (ATEX) Dimensions – Foot & flange mounted motor – Horizontal B34 (IM2101) or B35 (IM2001) Vertical V15 (IM2011) (5. +390114076311 .sicmemotori.2) : B34: B35: Flange with screwed holes Flange with through holes Dimensions – Flange mounted motor – Horizontal B5 (IM3101) or Vertical V1 (IM3001) Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel.Fax +390114500047 – www.com . page 8 of 12 .com – sicmemotori@sicmemotori. com – [email protected]) ФD d1 (DIN332) E F (h9) G GD (h11) 19.A. 15 149 114.sicmemotori.5 NPT 2“ M20x1.5 Tapered / Cyl.31 j6 172 3 3/8” UNC 45° C 11 FF-215 14 215 180 j6 250 4 14 C 13 FF-265 14 265 230 j6 300 4 C 16 FF-300 15 300 250 j6 350 C 19 / C19 H FF-300 13 300 250 j6 C 23 FF-500 22 500 450 j6 C 7 / C 7C Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel.-Metric Flange & Terminal Box Dimensions FF flange dimensions (mm) Motor type B55 TBH TBA TBB TBH1 b 8 - 132 140 140 132 22.A.43 4.5° 8 73 246 260 26 0 246 - Fl. Size LA ФM ФN ФP T ФS Α Holes Nr N.5 60 m6 M20X42 140 18 53 11 Tapered Cylmetric Tapered Cylmetric NPT 1 ½” 20x1. 117 5 224 10 60 304 455 164 143 108 160 10 325 14 279 70 337 498 164 152 121 180 12 375 14 318 70 382 542 250 163 133 212 22 465 18 356 90 446 685 243 176 149 225 18 485 18 457 120 545 722 273 175 228 260 304 249 287 325 278 317 355 346 371 416 440 491 529 74 254 140 178 210 254 203 241 279 228 267 305 286 311 356 368 419 457 190 190 280 22 580 22 Dimensions (mm) S1 (6. +390114076311 .5 N/A N/A NPT 2“ 63x1.1) Motor type L C7 / C7 C C11 C13 C16 C19 / C19 H C23 Note (6.57 22 j6 M8X19 50 6 18.5 6 28 j6 M10X22 60 8 24 7 32 k6 M12X28 80 10 27 8 7 8 48 k6 M16X36 110 14 42. page 9 of 12 .5 NPT 2½“ NPT 2½“ 75x1.C Series FLAMEPROOF DC Motors (ATEX) Main Dimensions Dimensions (mm) Motor type C7 / C7 C L S M L S M L S M L S M L S M L C 11 C 13 C 16 C19 / C19 H C 23 A AA AB AC AD B BB C C1 H HA HC ФK 165 57 241 347 122 N.1) L1 L 540 540 S M L S M L S M L S M L S M L 620 645 675 721 751 786 810 845 885 872 912 957 1145 1190 1245 580 605 635 685 715 750 775 810 850 840 880 925 1145 1190 1245 S2 (6.Fax +390114500047 – www.5 9 M25x1.5° 45° 4 50 150 160 160 115 20° 14 45° 4 52 142 160 160 111 15° 5 19 45° 4 58 138 160 160 108 20° 350 5 19 45° 4 55 188 260 260 161 15° 550 5 19 22.05 j6 M6X16 62 4.com .57 16. etc. even after being subjected to any maintenance operation. we must not forget that these machines must be able to work safely in areas at risk of explosion or fire. +390114076311 . operating and maintenance manual supplied by SICMEMOTORI. after ignition. in the presence of dust. file 319 and IEC 79-10 "Standards for systems in places with danger of explosion or fire. etc. in which.Fax +390114500047 – www. IIB. T3. In this case. the atmosphere is no longer considered to be potentially explosive. the motor must be re-examined by a competent certification body. A written declaration must be done with the description of the actions taken. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel. the entire quantity of dust is consumed by combustion). It is therefore indispensable to be aware that if any machine is in any way altered without the prior written permission of SICMEMOTORI.C Series FLAMEPROOF DC Motors (ATEX) ATEX 94/9/EC Directive (offprint) The ATEX Directive 94/9/EC applies to all mechanical and electrical products used in areas. The risk areas are areas where under certain conditions explosive atmosphere may develop The ATEX Directive 94/9/EC defines an explosive atmosphere as a mixture of: 1. The ATEX marking is COMPULSORY for all products that will be installed in potentially explosive areas within countries belonging to the European Union Warnings for the plant engineer Given the complexity and importance of the matter. In addition.com . 2. combustion spreads to the entire unburned mixture (not always. characteristic of the windings. In case of repairs that modify aspects relevant to Ex protection (see for example what earlier specified about explosion-proof joints) and the motor after the repair is no longer comply with the certificate. Repairs Repairs of explosion-proof motors must be conducted according to criteria specified by IEC 79-19 Standards. with air. If repairs are not made by SICMEMOTORI. they must be carried out in workshops which have the necessary equipment for repairs and technical knowledge relating to methods of protection of motors. In case of repairs on parts that influence the protection against the risk of explosion. manufacturing motors data must not be modified (for example: size of the joints. it is suggested that plant engineer which have to tackle a project that includes places at risk of explosion or fire refer to CEI 64-2 ed. The local authorities (fire departments. the plant engineer has to decide what is the real risk of explosion or fire in the area and which materials contribute to constitute a risk of explosion.. with a potential risk of explosion. 1973. the original motor name plate must be removed and the motor can no longer be considered suitable for use in areas with danger of explosion. however. and it is only this kind of atmosphere that is intended for products covered by the ATEX Directive 94/9/EC. flammable substances in the form of gases. built and certified . vapors.sicmemotori. mists (and dust). 3. VII. it can loose the characteristics that make it suitable for installation in hazardous environments and for which it was designed. the National Inspectorate) are the competent bodies to be approached for approval of a classification of a potentially explosive area.com – sicmemotori@sicmemotori. When one or more of the above elements is not present.) and the repaired parts must be tested . 4. page 10 of 12 . in certain atmospheric conditions.) must be removed. The Directive provides for the issuance of dual certificate: • The conformity of the prototype • The conformity of production (evaluation of the quality management system). it can no longer be classified as explosion-proof and all the symbols of identification (Exd. An atmosphere which could become explosive due to local conditions is defined as potentially explosive atmosphere." In general. with both gas and dusty ambience. Warnings for the user The Flameproof explosion-proof DC machines must be serviced regularly as per the. For further use in these areas. com .C Series FLAMEPROOF DC Motors (ATEX) Examples of certificates Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-DC-ATEX-7-28-E-11 Tel.com – sicmemotori@sicmemotori. page 11 of 12 .Fax +390114500047 – www.sicmemotori. +390114076311 . the technical characteristics. The motors are always supplied complete with the installation. drawings given in this catalogue are of a purely indicative nature and may be changed without prior notice. mining industries. from cranes & hoists to chairlifts & funiculars. CAUTION All information. etc. All data and indications shown in this catalogue have to be considered only as a guideline. these components can be dangerous since they are live and have non-insulated and rotating parts. SICMEMOTORI products can be found all over the world. SICMEMOTORI reserves the right to modify at any time and without notice the data. at first as a Division of SICME (producing wire enamelling plants) and then. to check status of their own orders. For particular cases in NON-industrial environments. Due to its long history.com). sugar centrifuges. or where other types of protection must be provided (for example against contact with children fingers. the weights and the illustrations. via a password. Production is managed by a modern “MRP” system.. the use and the maintenance are not respected. of the present catalogue must be authorized in writing by SICMEMOTORI. from iron & steel mills to rubber mixers (Banburies).sicmemotori. SICMEMOTORI refuses all responsibility for direct or indirect damages caused by possible errors and/or omissions in the present catalogue. use and maintenance or any modification/tampering with the motor makes the guarantee rights invalid and exempts SICMEMOTORI from any responsibility. Any use of the motor differently from the specifications indicated in this catalogue does not involve any liability for SICMEMOTORI as manufacturer. WARNING The motors and the electrical devices feeding them are electrical components installed on machines and industrial systems subject to high voltage. these guards or additional protections must be realized by the customer. Notes: Customers can determine whether a specific product is suitable for their needs and are thus responsible for the selection. . manufacturing and selling DC motors since 1962. The integrated IT system of the Company controls all its activities. Motors are produced according to ISO 9001 quality assurance system. to cement factories. The reproduction. data. and today SICMEMOTORI is one of the leading manufacturers of DC motors in Europe. the dimensions. to enter the company’s IT system. The information contained in the present catalogue does not guarantee the characteristics for the use. and all operations are controlled by bar code. The Company is organized on the principles of “lean production” and “learning organization”. use and results obtained by any product showed in this catalogue. The products listed in this catalogue are exclusively designed and built for industrial purposes. use and maintenance instruction manual. The Company is located in Turin. During operation. from order entry to the delivery of materials. in the North-West part of Italy.500 sqm.). etc. paper & print machines. More than 85% of SICMEMOTORI DC motors are directly or indirectly exported. even in part. selected and certified by SICMEMOTORI (the updated list is on SICMEMOTORI web site www. with a total surface area of approximately 10. from 1967. SICMEMOTORI has achieved a very high level of experience in the most severe applications. It is necessary to read and understand all the information contained before proceeding to connect and to start up the installation. Any non-observance of the rules for installation. If the above mentioned documentation is lacking. the after sales service is provided by a network of authorized repair shops. as an independent company. Customers are allowed. SICMEMOTORI shall not be held responsible if the products illustrated herein are used outside their limits of the specifications given. SICMEMOTORI is member of EASA. they can be extremely harmful to personnel and objects if the instructions for the installation. 12 . SICMEMOTORI products have followed the complete evolution of DC motors technology.C Series FLAMEPROOF DC Motors (ATEX) Some word about SICMEMOTORI SICMEMOTORI has been designing. Therefore. from the beginning its products have been well received because of their quality and reliability. plastic extruders and film process. in one of the most industrialized area of Europe. production is carried out in two plants. please request a copy to SICMEMOTORI.