SM TM 1.5-4 Guardsman(G)Series02002[1]
Comments
Description
Smith Meter Turbine Meters® 1.5" to 4" Guardsman (G) Series Issue/Rev. 1.0 (11/10) Bulletin SS02002 TM Specifications The Smith Meter ® Guardsman Series Turbine Meter is a bladed, rotor-type meter which utilizes an upstream, cantilevered stator to support the tungsten carbide, bearing-mounted rotor. It is intended for a wide range of petroleum, petrochemical, and chemical custody transfer measurement applications, such as small product pipelines ranging from Natural Gas Liquids (NGL) to light fuel oils. Features Stainless steel measuring chamber and internals. Locking stator to prevent wear and improve performance. Tungsten carbide bearing system provides long life on low lubricity liquids. Hydrodynamic thrust balance to minimize friction and wear on thrust bearings which allows for long service life and high accuracy. 125-250 AARH Flange Face Finish. 3" Model Code K2BDA Operating Specifications Flow Range 1 Normal Flow Range3 Meter Size Units2 Min. Linear 13 18 50 3 25 36 95 6 40 55 150 9 60 85 230 14 110 160 415 25 Max. Linear 140 200 530 32 280 400 1,060 64 420 600 1,590 96 650 930 2,460 148 1,200 1,700 4,500 270 Extended Max. Flow Rate3 190 270 710 43 375 535 1,415 85 560 800 2,120 128 870 1,240 3,280 198 1,600 2,270 6,000 360 Nominal K-Factor (Pulses/ Unit) ±5% 240 10,080 63.4 63,400 125 5,250 33 33,000 75 3,158 19.8 19,800 52.7 2,215 13.9 13,900 25 1,050 6.6 6,600 Options Bidirectional flow allows the meter to accurately register flow in either direction. Multiple pickup coils are used when direction sensing or pulse security is required. NACE compliance may be necessary when dealing with liquids containing hydrogen sulfide. The meter has housing materials which are certified to be in compliance with the material requirements set forth in NACE Standard MR-01-75 latest revision. Premium ±0.15% and Super Premium Linearity ±0.10%. AccuLERT ID-2000 Smart Preamplifier for real-time diagnostics of meter performance. 1.5" USGPM USBPH L/min m3/h USGPM USBPH L/min m3/h USGPM USBPH L/min m3/h USGPM USBPH L/min m3/h USGPM USBPH L/min m3/h 2" 3" LF 3" 4" Linearity Normal Flow Range Standard Premium Super Premium (3" and 4" ONLY) ±0.25% ±0.15% ±0.10% 1 Based on 0.8 sp. gr., 1.5 mPa·s (1.5 cP) liquid. 2 Metric units are nominal and may not convert precisely. 3 a. For bidirectional flow, the linearity in the reverse direction is ±0.25% and the mnimum linear flow rate is 20% of the normal maximum linear. b. From Normal Minimum to Extended Maximum, the linearity is normally not degenerated. c. Extended Minimum is the flow rate at which the meter can provide a reliable signal, but accuracy (linearity and repeatability) may be diminished. The Most Trusted Name In Measurement 440 (9. Applications High Viscosity The flow range of turbine meters is reduced considerably when metering viscous liquids.770) 1. AExd IIB T6 IP66.160 (14.Repeatability ±0. Electromagnetic Immunity: EN 55022. Minimum Back Pressure In order to prevent cavitation. and 40 DIN 2526 Form C flanges.600) 362 (2.9 Rate Increasing Factor = S Where: S = The specific gravity of the liquid being metered. Low Density When metering light hydrocarbons such as LPG or other liquids with specific gravity less than 0.5 psig 4 Maximum working pressures are for temperatures of -20°F to 100°F (-28°C to 38°C).896) 720 (4.030) 692 (4.480 (10. Chapter 5 recommends a minimum back pressure according to the following: BP = (2 x ∆P) + 1.02% over the entire normal range. IEC Ex PTB 08. The following relationships can be used to approximate the increase (reduction in range) that will maintain the stated linearity. Level 2 (1kV). Tamb -50°C to 70°C. IEC 61000-4-3: Radiated Electromagnetic Field.8.210) 274 (1. 300.500) 580 (4. EN/IEC 60079-1: Electrical apparatus for potentially explosive atmospheres – Flameproof enclosures 'd'. Viscosity (cP) = x Rate Rate Meter Size (in) Note: Caution should be used when dealing with liquids that result in a viscous minimum rate greater than two times the normal.25 (50) = 70. PN 16.M. Level 3+ (8. Installation Class 3. Listed 557 N – Class I Groups C and D. Degrees of protection provided by enclosures (IP code). 1.0 (11/10) .220 (15.929) 2. CNL-CSA ENCL. Page 2 • SS02002 Issue/Rev. End Connections Class 150. Refer to the installation manual for full instructions. Except 430 Stainless Steel Blades and Cones Tungsten Carbide Journal and Bearings Installation The meter must be mounted in a horizontal attitude (±5°) within a suitable flow conditioning assembly. ATEX / IEC Ex PTB 08 ATEX 1034X.400) 1. 900 ANSI B16. PN 63.307) Carbon Steel Flanges 232 (1. IEC 61000-4-4: Electrical Fast Transient (Burst). API M.P.∆P = 4 psi. the flow range should be shifted upward.102) 1.0040X Ex d IIC T6 Tamb = -40°C to 70°C IP66. since variations in operating temperature can result in substantial meter factor shifts. EMC Compliance: (by Council Directive 2004/108/EC) Electromagnetic Emissions: EN 61000-6-3.000 BPH .000) 928 (6.000) Stainless Steel Flanges 275 (1. 125-250 AARH finish raised face (RF) flanges.893) Stainless Steel Flanges 176 (1. Class I.S. Absolute vapor pressure of butane at operating temperature . Class I. It is recommended that the meter be installed downstream of a strainer for protection and upstream of the flow control valve in the system. Zone I. Criterion B. EN 60529: 1992. 600.965) 740 (5. The minimum flow rate must be increased as the viscosity increases. 4. 4. Normal Min. Essential Health and Safety Requirements EN/IEC 60079-0: Electrical apparatus for potentially explosive atmospheres – General requirements. Maximum Working Pressure4 – PSI (kPa) ANSI 150 300 600 900 DIN PN16 PN25 PN40 PN63 PN100 Carbon Steel Flanges 285 (1. 12 kV by air).098 (7. BP = (2 x 4) + 1. Zone I. 25.25 Vp Where: BP = Minimum back pressure ∆P = Pressure drop at maximum flow rate VP = Absolute vapor pressure at operating temperature Example: 3" Guardsman at 1. Group IIB. Consult factory for maximum working pressures at other temperatures.205) 2. UNL-UL ENCL. The amount of shift can be approximated by multiplying the normal minimum and maximum flow rates by the following factor: 0.964) 1. Approvals UL/CUL. IEC 61000-4-2: Electrostatic Discharge (ESD). IEC 61000-4-5: Electrical High Energy Pulses (Surge).5.450 (10. Level 3 (10 V/m).890) 439 (3.570) Materials of Construction Body Flanges Internals Bearings and Thrust Washers 300 Series Stainless Steel Carbon Steel Optional: 300 Series Stainless Steel 300 Series Stainless Steel.0 kV by contact. Operating Temperature Range Meter with Pickup Coil Pickup Coil and Preamp Pickup Coil & Preamp with 24" Standoff Carbon Steel Flange -20˚F to 225˚F -29˚C to 107˚C -20˚F to 158˚F -29˚C to 70˚C -20˚F to 225˚F -29˚C to 107˚C Stainless Steel Flange -40˚F to 225˚F -40˚C to 107˚C -40˚F to 158˚F -40˚C to 70˚C -40˚F to 225˚F -40˚C to 107˚C Consult factory for higher temperatures. Viscous Min.Vp = 50 psia. and 100 DIN 2526 Form E flanges. UL/CUL Listed 3 .UL/CUL/CRN Position 11: Specials 0 .Super Premium ±0.3" BE .1 Pickup Coil and AccuLERT6 XU T .2 Pickup Coils and AccuLERT6 XU Extended Temperature Range with Preamplifier D .000 ft (610 m) using #20 AWG two-conductor. This code is part of the ordering information and should be included on the purchase order.1..3" Low Flow BD .PN100 Position 8: Pickup Coils and Preamplifiers Meter Mounted Junction Box(es) with 0 .0 (11/10) SS02002 • Page 3 .Class 600 EF . 1 K 2 2 3 B 4 A 5 A 6 0 7 A 8 0 9 0 10 0 11 0 Position 1: Code K .Standard ±0.Class 600 E0 .Unidirectional Flow.2 Pickup Coils and 2 Preamplifiers 4 . Germany facility.2 Pickup Coils and 2 Preamplifiers on 24-Inch Stand-off Extended Temperature with Online Diagnostics with E .200 Ω (±10%).5" BB . Maximum Transmission Distance: 2.Class 900 DIN End Connections Carbon Steel RF Flg’s.000 Hz. 7 PED required for all European Countries.PN40 LF . 6 The AccuLERT also provides dual channel preamplification and online diagnostics.4" Positions 5 and 6: Pressure Class and End Connections ANSI End Connections Carbon Steel RF Flg’s. 10 ∆P 1 PSI 0.ATEX / IEC Ex Certified 4 .Specify Position 7: Internal Configuration A . 430 Stainless Steel Blades 5 Super Premium ±0.Class150 BF .0 mPa•s (2.PN63 M0 .25% Linearity 1 .10% Linearity5 Position 10: Compliance with Electrical and Other Standards 0 . shielded cable. Issue/Rev.Premium ±0.Class 150 B0 .PN16 JF .Barrel per Hour Data based on 0.Cubic Meters per Hour 2 10 8 6 4 20 2 4 6 10 20 40 60 100 200 300 60 40 Electrical Characteristics Effective Series Resistance (Re): 1. 2" and 3" Low Flow.6 0.000 Flow Rate . H0 .PN25 K0 .5" 2" 3" LF 3" 4" 6 4 ∆P kPa Catalog Code The following guide defines the correct turbine meter for a given application and the respective catalog code.ATEX / IEC Ex / PED Certified7 5 .Bidirectional Flow. gr.1 10 1 0. 1.0 cP) viscosity. 430 Stainless Steel Blades B .8 sp.1 Pickup Coil and AccuLERT6 XU on 24-Inch Standoff K .5".Class 900 300 Series SS RF Flg’s.PN25 KF . equipment must be manufactured by Ellerbek.1 Pickup Coil and 1 Preamplifier on 24-Inch Stand-off J . HF .Pickup Coil Specifications Type: Variable reluctance. Le Vo Re Pressure Drop Flow Rate .PN63 MF .2 Pickup Coils and 1 Preamplifier Pickup Coil(s) with Online Diagnostics with S .2 Pickup Coils 3 .Class 300 DF .15% Linearity 2 .PN40 L0 .8 0. 2.PN16 J0 . 1.2 Pickup Coils and AccuLERT6 XU on 24-Inch Standoff Position 9: Testing/Linearity 0 .2" BC . A0 .1 Pickup Coil and Preamplifier 2 .Class 300 D0 .PN100 300 Series SS RF Flg’s.Turbine Meters Position 3 and 4: Model Guardsman G Series .8 20 40 60 100 200 400 600 1. Note: A preamplifier is recommended for remote instrumentation that does not have Common Mode Noise Rejection. Minimum Open Circuit Voltage (Vo): 300 millivolts p/p at minimum flow rate. See Bulletin SS02006 for PA4 Preamplifier Specifications.000 2.Catalog Code Position 2: Product Line 2 .None X . AF .4 2 0.Journal Bearings BA . Effective Series Inductance (Le): 400 mH @ 1.1 Pickup Coil 1 .2 0.10% Linearity is not available for Sizes 1.Special . .com/measurementsolutions and click on the “Contact Us” link in the left-hand column............0 (11/10): PTB issued ATEX and IEC Ex Certifications..... Russia +7 (495) 5648705 Singapore..........inches to the nearest tenth (millimetres to the nearest whole mm).5" 2" 3" and 3" LF 4" C 5....3" (211) 10...5" 2" 3" and 3" LF 4" A7 6..............0" (152) 6.5" (165) 10. Note: Meter weights by flange class with one pickup coil and explosion-proof box..1" (155) 6............ Germany +49 (4101) 3040 Barcelona.. 8 Add 24" for a standoff when using a preamplifier for temperatures 158°F to 225°F (70°C to 107°C)... Bulletin SS02015 7 For Class 150-600.... United Arab Emirates +971 (4) 883 0303 Los Angeles..... each independently dimensioned from respective engineering drawings. Headquarters: 500 North Sam Houston Parkway West.2" (235) Weight 18 (8) 20 (9) 60 (27) 66 (30) Weight 24 (11) 33 (15) 45 (20) 110 (50) A 9.1" (155) 6... China +86 (10) 6500 2251 Buenos Aires.... Spain +34 (93) 201 0989 Beijing......... Argentina +54 (11) 4312 4736 Burnham.... Houston.5" (241) 11.5" (165) 7.. For the most current contact information... the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.. SS02002 Issue/Rev... TX 77067 USA.60 Degrees First Coil (Optional) Class 150 ANSI Size 1... TX USA +1 (361) 289 3400 Kongsberg..fmctechnologies... England +44 (1628) 603205 Dubai.0" (152) 7....... Inc.5" (191) 9...6" (142) C 5....0" (229) 10........ Otherwise..........S..fmctechnologies.3" (211) 10......5" (165) 8.4" (162) 6....0" (254) 12.... PA USA +1 (814) 898 5000 Ellerbek. Bulletin SS02012 Flow Conditioner Specification .......0" (254) Weight 19 (9) 24 (11) 76 (34) 80 (36) Class 600 ANSI C 6. Australia +61 (3) 9807 2818 Moscow..3 kg) for each additional pickup coil and explosion-proof box..........0" (305) B8 6.6" (220) Weight 13 (6) 20 (9) 55 (25) 60 (27) Class 300 ANSI C 6........9" (200) 9...1" (130) 5....... Phone: +1 (281) 260 2190...0" (229) 9..8" (274) PN25/PN40 C 5.. Add 5 lb (2... 1..0 (11/10) . CA USA +1 (310) 328 1236 Melbourne.5" (65) 8..... +65 6861 3011 Thetford....... visit our website at www..... The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect....9" (150) 6....... All rights reserved.... Contact information is subject to change.... England +44 (1842) 822900 Integrated Measurement Systems: Corpus Christi..0" (127) 6.......Dimensions Inches (mm) and Pounds (kg) A 2 2" (51) A 3" (76) Explosion-Proof Box Note: Dimensions .... Bulletin SS02007 AccuLERT Smart Preamplifier Specification .9" (150) 6..5" (165) 7.....6" (168) 5...... 1............... United Arab Emirates +971 (4) 883 0303 Visit our website at www........A......... +/.....0" (305) Class 900 ANSI C 7....... Norway +47 (32) 286700 Dubai... 1" NPT C B Second Pickup Coil Spaced 90 Electrical Degrees.....com/measurementsolutions Printed in U.......... Fax: +1 (281) 260 2191 Measurement Products and Equipment: Erie.........0" (229) Weight 14 (6) 20 (9) 65 (30) 65 (30) PN16 Size 1.5" (216) 9..0" (178) 8. © 6/92 FMC Technologies Measurement Solutions..0" (254) 12. Revisions included in SS02002 Issue/Rev..5" (292) Weight 40 (18) 65 (30) 152 (69) 160 (72) Related Publications PA-6 Preamplifier Specification . Suite 100..9" (200) 8.
Copyright © 2024 DOKUMEN.SITE Inc.