Server Load SimulatorModel SLS-10 10 KW CFM-Trim Control for Delta-T Adjustment Standard 9U Rack Design Overtemperature Protection Convenient Handles for Sliding in and out of Server Racks Touch Safe Terminal Connections The Avtron Server Load Simulator Model SLS-10 is a self-contained, rack-mounted unit that simulates the actual heat loading of a computer server. The SLS-10 is designed for data center heat-load testing and server placement during the data center design and construction stage. In today’s high power data center environments, it is absolutely critical to design and test the facility HVAC cooling system prior to installation of the actual servers themselves. The Avtron Server Load Simulator mimics the exact heat output of the actual server under load and has the same form factor and dimensions as the servers themselves, whether they are conventional low power density servers (2-6 KW per rack) or the new high-density blade servers (up to 24 KW per rack). This real-world heat loading using actual Avtron Server Load Simulators is far more accurate and precise than using conventional HVAC software simulation (without any heat loading). Potential heating problems can be easily identified and corrected using the SLS-10 Server Load Simulator. supply or from internal load power. The SLS-10 draws in cool air through it’s front side from the “Cold Aisle”. The hot air exhaust is then discharged through the rear of the unit into the “Hot Aisle”. The unit also features CFM “Trim-Control” to decrease the Delta-T across the unit. The Avtron Server Load Simulator is rated for single phase 120, 208, 230, or 240 VAC input with a power output up to 10 KW total. The 10 KW total rating of the SLS-10 (in 240 VAC mode) is greater than most competitive units! This saves time and money when performing a data center server load simulation since fewer units are needed. The SLS-10 load simulator is 9U (15.75" [400]) high and designed to fit into an industry standard rack(s). Cold-side blanking panels (to prevent recirculation of hot air) are available as an option. Avtron’s extensive line of Load Bank and Industrial Resistor Products are solid performers used throughout the world. The Avtron SLS-10 is self-cooled with two integral cooling systems (one per channel) which operate from a 120 VAC, single phase external power For total technical support or additional information, please contact Avtron at (216) 573-7600 or [email protected]. power test solutions Legendary Avtron quality combined with simple operation and maintenance will provide years of trouble free service. Channel 1 can have 120 V applied and Channel 2 can have 240 V applied.00] 18.125R [3] TYP 6 PLACES 1.00] 1. 2 CHANNEL SCCR RATING: 5KA RMS SYMMETRICAL SCHEMATIC DWG: D50714 SERIAL NUMBER: 23.375 [161.00] 6.Server Load Simulator Model SLS-10 OUTLINE DRAWING: 19.573.50 [38.5953 www.75” [400]) high.avtronloadbank.com Bulletin 445 • Rev.573.) SAFETY FEATURES: Touch safe terminal connections.7600 • FAX 216. Ohio.00 [483. 44125-4615 • 216. 208.375 [161.250 [464. Quality System Certified to ISO 9001 6255 Halle Drive • Cleveland.e..75 [400.00] CHANNEL A TB4 TB1 1 2 1 2 3 4 5 6 TB2 1 2 SLS-10 SERVER LOAD SIMULATOR MODEL/SYSTEM: SLS-10-D50687 RATING: 10KW @ 230V.00] +200 +CFM TRIM OVERTEMP CHANNEL A TB3 CHANNEL B 1 2 3 4 5 6 CHANNEL B 0. and automatic fan-run circuit for element cooling at shut-down. 240 (channels can operate with independent voltages i. control circuit fusing. LOAD VOLTAGE (VAC): 120.50 [596.00] ON ON MASTER LOAD 1 MASTER LOAD 1 0 0 STEP 1 1 STEP 1 1 0 0 STEP 2 1 STEP 2 1 0 0 STEP 3 1 STEP 3 1 0 0 +0 +200 +CFM TRIM +0 OVERTEMP 6. 230.S. U. overtemperature protection.A. OPTIONS: Cold-side blanking panel 9U (15. Specifications subject to change without notice.00] MAX SPECIFICATIONS: CHANNELS TOTAL: 2 INPUTS per CHANNEL: 1 RATINGS per CHANNEL (multiply x2 for TOTAL LOAD): STEP 120 VAC* 208 VAC* 230 VAC* 240 VAC* 1 529 844 1035 1173 2 1026 1706 2141 2382 3 1030 1683 2117 2340 1+2 1469 2545 3167 3528 1+3 1469 2556 3170 3500 2+3 1860 3420 4231 4669 1+2+3 2202 4277 5288 5796 *Measured Values – Voltage changes at input accounts for non-adding steps.00] 15. - .com • LBsales@FNFSTon. All dimensions are in inches [millimeters].62 [41.