Sffeco Electrical Diesel Jockey Pumps

March 27, 2018 | Author: manox007 | Category: Pump, Engines, Cylinder (Engine), Fire Sprinkler System, Mechanical Engineering


Comments



Description

F F F F F FFoam Systems Deluge Systems Hydrant Systems Sprinkler Systems Hose Reel Systems Hose Rack Systems CO MPA N Y P R O F I L E SFFECO (Saudi Factory for Fire Equipment Est.) an ISO 9000:2008 Certified Factory with its Head Quarter at Riyadh, K.S.A, is one of the largest Fire Fighting Equipment Manufacturing Facilities in the Region. It was established in 1983 with state of the art manufacturing facility for a wide range of fire fighting equipments. SFFECO With over 750 Employees & Highly Qualified team of Professional Engineers can supply a wide spectrum of Fire Fighting Products, along with its own Comprehensive Designs, Installations, & Commissioning, besides to the necessary Consultancy Services in the Field of Fire Fighting as per the National & International Standards & Codes. SFFECO Reputation for Quality & Reliability has made its trusted name through out G.C.C & other Countries Worldwide for its Products. SFFECO is not only rich in History & Quality, but on continuous improvement, & development of product features. SFFECO is a member of National Fire Protection Association (NFPA), British Standards Institution (BSI), Fire Protection Association (FPA), as well as Approved Vendor to Many Governmental, & Semi Governmental Sectors in G.C.C. SFFECO Vision to develop with Wisdom & Prosper in Harmony, and continue to be the leader in the Fire Protection industry providing excellent service & superior products for many years to come. 2 www.sf feco.com Excel Series is the right Choice for most of the Fire Fighting Applications. Wired. Succeeded developing the “Excel SERIES” Pre. Assembly. easily to Handle . and Tailor Pump Packages to clients’ specific needs. Controllers are all skid Mounted. • Foam Systems. Ware houses.where all Pumping Elements. • Hydrant Systems. with pressure range from 6 bars up to 12 bars.Fabricated Fire Pump Skids. S F F E C O FIRE PROTECTION ENGINEERS 3 . Excel Series Standard Packages included wide variety of Fire Pump Units start from 50 GPM size up to 1500 GPM. as well as NFPA . and Pump Packages Testing…. Government Buildings. Pre-piped.SY ST E M TE C H N O LO G Y S F F EC O F i r e P u m p Sys t em T ech no lo gy Being Local Specialist Manufacture gives SFFECO the Opportunity and Privilege to Develop an Innovative Pump Assembly Units.20 Selection and Operation Procedures. • Automatic Sprinkler Systems. where this developed technology assure providing Compact Design Pump Sets. Moreover SFFECO has assured supplying Pump units comply with Local Authority Requirements. This wide Range of Pumping & Head Characteristics has Made Excel Series suitable in various market sectors such as.Install.& Maintain . SFFECO Highly Skilled Team has over 25 years Combined Experience in Design. • Fire Hose Cabinet Systems. Commercial and Residential Towers. Factories etc. Drivers. • Deluge Systems. & Factory tested . J. 150.D.PA CK A G E AS S E M B LY M O D E L S “Excel Series” Packages Offers Completed Skid Mounted Unit including High quality Horizontal End Suction / Split case Pumps that coupled with Heavy duty (Electrical/ Diesel) drivers that assembled with full discharge line control Gate & Check Valves along with flexible joints. Excel Fire Pump .J 4 www. 500. & Vertical Jockey (maintenance) Pump that all are assembled with discharge line accessories. & fabricated in Common Compact Skid is Fully Automatic Operated through latest Design Control Panel. 250. 300.D. Model Consist of Main End Suction Diesel Pump driven by Diesel Engine.com . Excel -E.J. 350.J Excel Fire Pump . Stand by End Suction Diesel Pump driven by Diesel Engine. 750 & 1000) GPM. Available Flow Capacities (50.E. wired. & Vertical Jockey (maintenance) Pump that all are assembled with discharge line accessories. as well as Hazard application needs. 500. 350.sf feco. 150. 750 & 1000) GPM. The Standard Models of “Excel Series” are as Follows. “Excel Series” Innovated design has different Combinations & Models that suite different clients requirements. as well as connected with Skid Mounted Control Panel.D. as well as connected with Skid Mounted Control Panel. 120. Model Consist of Main End Suction Pump driven by Electrical Motor. 300. Excel -D. where all pre-piped. Pressure Switches & Gauge fitted on well Supported Header. 120. 250. Available Flow Capacities (50. as well as connected with Skid Mounted Control Panel. all are assembled on I-Beam base separately .where discharge line Accessories & Control Panel are supplied loosely . 1000.E. (or /and) Vertical Jockey (maintenance) Pump. 750 & 1000) GPM. S F F E C O FIRE PROTECTION ENGINEERS 5 . Excel -E.). .250. (or /and) Split Case Diesel Pump driven by Diesel Engine. . 1500) GPM.) as Main & Stand by. Available Flow Capacities (50. But this model is most in the following Conditions.E. 120.J Horizontal Split Case Model Consist of End Suction/Split Case Pump driven by Electrical Motor. 150.Pressure Tank as additional on the skid or substitute to the Jockey Pump. 350. 300. 500.g. • Split Case Pump Bare Shaft. • High Pumping Head above 9 Bar Note: Optional Provision are also available in Excel Series can be Ordered up on Request such as. or Double Diesel (D.PA CK A G E AS S E M B LY M O D E L S Excel Fire Pump . Available in all Excel Series pumping flows (as per client request).D. 1250. & Vertical Jockey (maintenance) Pump that all are assembled with discharge line accessories. Model Consist of Main End Suction Pump driven by Electrical Motor.J. • Flow Capacity above 750 GPM (e.Different Combinations Double Electric (E. D.com .5/50 5.5/35 5.J TYPE DJ DJ DJ DJ DJ (GPM) 750 500 250/300 120/150 50 W (MM) 1100 1000 800 800 700 H (MM) 1760 1670 1420 1280 1230 L (MM) 1700 1600 1220 1220 830 DIESEL (HP) 85 60 25 25 10 JOCKEY (HP/GPM) 5.5” EXCEL Skid Model .5 JOCKEY (HP/GPM) 5.5 5.sf feco.5/25 3/20 3/15 3/10 3/10 (KG) 1500 1200 1092 950 870 780 300 HEADDER PIPE 6” 6” 6” 4” 4” 2.E.5/35 5.5” Note: These are our standard models.J TYPE EJ EJ EJ EJ (GPM) 500 250/300 120/150 50 W (MM) 900 800 800 700 H (MM) 1660 1420 1250 1230 L (MM) 1350 1220 1220 830 MOTOR (HP) 50 30 15 5.J TYPE EDJ EDJ EDJ EDJ EDJ EDJ EDJ (GPM) 1000 750 500 350 250/300 120/150 50 W (MM) 1700 1700 1600 1550 1220 1220 650 H (MM) 2220 1680 1680 1630 1420 1300 1250 L (MM) 2000 1800 1800 1600 1220 1220 1230 DIESEL (HP) 110 85 60 40 25 15 8 MOTOR JOCKEY (HP) (HP/GPM) 100 75 50 40 30 15 5.E. 6 www.5/25 3/15 3/10 3/10 (KG) 640 432 310 170 HEADDER PIPE 6” 4” 2” 1.D.PU MP SK ID S P E C I F I C ATI O N S EXCEL Skid Model . Other specifications are also available as per customer request.5/25 3/15 3/10 3/10 (KG) 850 730 540 480 190 HEADDER PIPE 6” 6” 4” 2” 1.5” 2” EXCEL Skid Model . S K ID PA CK AG E C O M P O N E N TS Horizontal Split Case Pump • Capacity up to 1500 GPM with Pressure up to 12 bars. Residential and Applications. • Available in Electrical Motor or Diesel • Suitable for Commercial.Horizontal Split Case MODEL SFS 125/38 SFS 150/38 Inch Suction/ Discharge 6” / 5” 8” / 6” Speed (RPM) 1760 1760 (GPM) 500/750 1000/1250 Head (m) 70 70 Impeller Size (mm) 380 375 SFFECO Centrifugal Pump .High Quality Cast iron Casing with Bronze wearing ring. • Engine configuration. • Split case design for easy maintenance & Upkeep. SFFECO Centrifugal Pump . & bearing Housing. Industrial • Suction & Discharge flanges are on common Horizontal center line. • Removable drip pocket with tapped drain Outlet stuffing box. • Standard Construction of : . Due to easy removal of Upper casing &Inner assembly without disturbing piping Including Stuffing boxes.Bronze Impeller . • American Design in compliance with (UL) & NFPA -20 Selection Requirements. .420 SS Shaft with 322 SS/ Bronze Sleeves.End Suction MODEL SFE 80/20 SFE 80/26 SFE 80/32H SFE 100/26 Inch Suction/ Discharge 4/3 4/3 4/3 5/3 Speed (RPM) 2900 2900 2900 2900 (GPM) 500 500 500 750 Head (m) 63 90 145 96 Impeller Size (mm) 214 264 329 264 S F F E C O FIRE PROTECTION ENGINEERS 7 . • Grease lubrication ball bearing provide L-10 rating • Double suction type impeller offers low Pulsation. • Suitable for Commercial. assure smooth operation& long bearing life limit • U.5” 3” / 2.com Inch Suction/ Discharge 2.5” / 2” 3” / 2.5” / 1.5” 3” / 2.sf feco.20 Selection Requirements. • Rear pull out design supplied as standard with spacer coupling that allow removal of rotating elements without disturbing piping Connection.5” 4” / 3” 4” / 3” 4” / 3” 4” / 3” 5” / 4” Speed (RPM) 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 (GPM) 150 300 350 500 750 500 750 750 1000 1250 1000 Head (m) 82 75 75 82 120 128 70 130 115 155 135 Impeller Size (mm) 214 214 214 214 264 264 214 264 264 264 264 50 Hz 2900 RPM are available as per customer requirement MODEL SFF 40/26 50 Hz 2900 RPM SFF 50/26 SFF 50/26A SFF 50/32H SFF 65/26 SFF 65/32H SFF 80/32H SFF 100/32H SFF 100/32HT SFF 125/32H 8 www.5” / 2” 2.5” 2.5” 4” / 3” 5” / 4” 5” / 4” 6” / 5” Speed (RPM) 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 (GPM) 150 300 350 350 500 500 750 1000 1250 1500 Head (m) 90 87 80 130 87 135 134 138 140 132 Impeller Size (mm) 264 264 264 329 264 329 329 329 339 329 .5” / 1.5” / 2” 2. Residential & Industrial applications.K.5” / 2” 3” / 2.5” 2.S K ID PA CK AG E C O M P O N E N TS SFFECO Centrifugal Pump .5” 3” / 2.End Suction • Capacity up to 750 GPM with pressure Up to 10 bar. • Top centre line discharge with foot supported casing MODEL SFF 40/20 SFF 50/20 60 Hz 3500 RPM SFF 50/20A SFF 65/20 SFF 65/26A SFF 65/26H SFF 80/20 SFF 80/26 SFF 80/26H SFF 80/32H SFF 100/26H Inch Suction/ Discharge 2. design in compliance with ANSI & NFPA . • Hydraulically balanced Impeller.5” / 2” 2. • Available in Electrical motor or Diesel Engine driven configuration. 27~6. & max. that arranged to allow power take-off through a flexible coupling directly from motor shaft “rotating element”.1~3.S K ID PA CK AG E C O M P O N E N TS Vertical In-line Pump Vertical In-line pump is designed such that motor may be removed without complete dissemble of the pump.52 5.Motor has IP55 Protection. Of 155 °C at the machine spots. Moreover Class F insulation allows temperature rises up to 100K. the vertical in-line has a centre line suction and discharge with a space saving design. which have been designed according to the EIC standards.K.52~5. Centrifugal Vertical In-line Item No.31~5.5” 3. The enclosed impeller may be dynamically balanced and the renewable wearing maintains peak efficiency. The impeller is designed to reduce end thrust. HITEC motors can handle load.72 3. & continue working reliably for long hours. also the precision balanced design ensures super performance with minimum energy consumption. Cathode Copper Stator. with special features & characteristics have made HITEC Motors Durable Motors & Components. where both are insulated by low-carbon magnetic steel laminations. Low Vibration design “Silent Functioning”. & Shield Ends (Drive/Non-Drive) from Cast Iron. & pre-packed with grease . Each impeller has back pull out vanes to provide a clear passage way against material build up behind the impeller. designed motors.27 1450 1450 1760 1760 400 750 500 1000 KTG125/32 KTG150/40 KTG125/32 KTG150/40 5” 6” 5” 6” Maximum Working Pressure 230 psi 230 psi 230 psi 230 psi 230 psi Type 2½x2½-8 5x5-13 6x6-16 5x5-13 6x6-16 Electric Motor HITEC motor plays a vital role in “Excel Series” Fire Pump Packages as it is Electrical Motor fire pump driver on both Main (or/and) Standby Operation. where this power is designed to allow the working space required for serving a fire pump when a pump is directly connected to a Motor. Larger pumps have an additional wearing in the rear to provide additional wear resistance. Corrosion proof construction. The Motor Shaft made of superior grade Steel. S F F E C O FIRE PROTECTION ENGINEERS 9 . along with Ball Bearing fully sealed. and Fan Cooling with Steel Cover protection of IP 2 x. HITEC Induction motors are U. Temp. & trouble free performance that easily to maintain. The back pull out design is convenient when there is a need for inspection. 1 2 3 4 5 Rated Head (PSI) 62~88 45~54 51~83 48~80 80~120 Rated Rated Rated Refer Suc/ Head Speed Capacity Bulletin Dis.Dia (Bar) (GPM) (GPM) 4. & Aluminum Rotor.52~8. HITEC standard construction of the Motor Frame. repair or for changing the impeller without disturbing the piping system.07 2900 200 KTG65/20II 2.7 3. 0 78.7 5.3 100.2 HM 802 .89 60.5 7.0 89.46 97.4 HM 315M .5 91.15 7.87 0.2 HM 200L2 .85 241.89 2.84 0.0 75.4 HM 132M .5 91.6 22.75 1.16 289.5 22 30 37 45 55 75 90 110 132 160 200 1 1.1 36. 2 POLE HM 801 – 2 HM 802 – 2 HM 90S . 16.59 98. 380-660V.74 71.4 2.380-460V.2 93.9 6.4 HM 280S .7 103.89 0.89 0.82 0.5 2 3 4 5.2 6.0 81.0 79.4 HM 90S .83 0.51 290.86 0. 60 Hz.3 139.85 0.5 2 3 4 5.87 0.8 94.8 15.4 75.88 0.2 HM 315S -2 HM 315M .0 85.2 HM 160M1 .90 0.2 HM 160M2 .4 At 60 Hz KW HP 0.5 94.18 26.0 82.0 0.4 HM 100L2 .6 94.77 0.5 2.4 HM 112M .80 20.5 11 15 18.3 8.8 34.40 9.85 0.3 92.5 11 15 18.70 35.91 0.95 578.9 21.89 0.0 240.0 89.3 348.3 28.2 HM 250M .0 94.83 0.0 87.2 HM 112M .2 HM 280M .5 10 15 20 25 30 40 50 60 75 100 125 150 175 220 270 Speed Current Efficiency Factor Torque (R.91 0.2 HM 315L1 .2 195.4 HM 225M .82 0.4 HM 225S .0 77.2 279.84 0.12 119.6 166.85 48.8 8.96 198. 60 Hz.4 HM 160L .9 82.5 94.0 92.87 0.0 88.72 5.48 49.4 HM 90L .0 14.5 17.2 HM 280S .90 0.85 0.5 21 25 33 41 63 70 110 120 135 165 218 230 280 365 495 565 890 980 1055 1110 16 23 25 33 35 41 65 76 118 132 164 182 245 258 290 388 510 606 910 1000 1055 1128 MAINS SUPPLY 220-380.4 HM 180M .8 359.4 233. 3 PHASE.95 13.88 0.2 HM 90L – 2 HM 100L .sf feco.87 0.1 1.50 10.Model MAINS SUPPLY 220-240.77 0.20 Noise LwdB(A) 67 67 72 72 76 77 80 80 86 86 86 89 92 92 92 93 94 94 96 96 99 99 58 61 61 64 64 65 71 71 75 75 76 76 79 81 81 83 88 86 93 93 97 97 Weight Kg.54 3.6 69.4 HM 315L1 .4 HM 160M .4 HM 315L2 .5 10 15 20 25 30 40 50 60 75 100 125 150 180 220 270 1 1.79 707.7 41.8 94.8 2.0 55.8 93.0 87.1 11.2 3 4 5.2 HM 225M .5 67.78 144.79 0.5 43.5 7.81 0.93 160.4 HM 200L .4 HM 132S .5 22 30 37 45 55 75 90 110 132 160 200 0.2 HM 315L2 .0 90.90 0.92 0.85 0. 2 POLE 10 www.91 0.com .30 71.0 85.6 3.87 0.4 287.92 0.0 92.88 0.5 7.4 4.5 93.0 88.4 134.51 423.1 1.19 142.9 95.90 0.4 HM 100L1 .4 HM 180L .94 5.0 2.2 HM 132S2 .90 0.02 512.12 120. 3 PHASE.4 HM 250M .2 92.37 354090 483.5 2.39 352.87 0.2 3 4 5.75 640.84 0.4 HM 315S .2 94.P.8 11.89 1028.75 1.0 83.2 HM 160L – 2 HM 180M .85 0.M) A % Cos Nm 3400 3400 3420 3450 3450 3455 3490 3550 3485 3550 3490 3545 3545 3550 3560 3555 3560 3575 3575 3575 3575 3575 1730 1710 1715 1710 1730 1730 1730 1760 1755 1760 1760 1765 1770 1775 1775 1775 1780 1780 1785 1780 1780 1785 1.22 18.8 73.8 94.3 30.0 90.53 36.0 80.9 3.91 0.0 93.04 7.11 24.5 92.70 176.4 HM 250S .88 0.0 90.0 84.23 14.5 7.0 92.4 160.2 HM 200L1 .9 84.87 0.2 HM 132S1 .96 1286.0 86.9 201.41 848.90 0.2 57. 85*4. Strong Reputation & Reliability. also calibrated to specific Power & Speed requirements to ensure Maximum Efficiency. Easy to Maintain & Optimum Performance. All Power units are manufactured to comply with strict control procedures & fully tested against the applicable standards in line with client requirements.65 4. thus guaranteeing the product best suited to the application. Forged Steel Connecting Rods.7 42 mm 48 mm 48 mm 60 mm 60 mm 60 mm 65 mm 65 mm 3 7 7 7 7 9 13 15 S F F E C O FIRE PROTECTION ENGINEERS 11 . & Steel No.Mega-Force Model M400 MFS25 MFS40 MFS60 MFS75 MFS85 MFS110 MFS150 MFS170 Type Air Cooling Vertical Water – Cooling.22*4. Mega-Force standard construction of Engine Block. where the Crankshaft & Flywheel Assembly is made of strength modular cast iron or alloy steel equipped with balance weight.S K ID PA CK AG E C O M P O N E N TS Diesel Engine Mega-Force engine plays a vital role in “Excel Series” Fire Pump Packages as it is Diesel engine fire pump driver on both Main (or/and) Standby Operation. Mega-Force range offers from small cylinder engine giving an output of 19 KW at 2900 RPM to a high powered configured engine of 400 KW. Heavy Duty. Mega-Force is U.13 4.78*4. direct-injection combustion chamber No. Diesel Engine .33*4. Agricultural & Industrial Sectors.5*1. Equipped with Radiator Cooling.15*3.7 3. where this power is designed to allow the working space required for serving a fire pump when a pump is directly connected to an engine. Electrical Starter. Such wide range has made Mega-Force suitable choice for many applications like Fire fighting.15*3. Construction.90 4. Cylinder Head Assembly made of Alloy Casting Iron.02*4.02*4.13 3. Bearing of steel & high tin Aluminum alloy.92 Rated power/ Speed (hp/r.65 4.K designed engine that has been engineered to have Longer Life Limit. & Flexible Exhaust.pm) 10 HP / 2900 25 HP / 3000 40 HP / 2900 60 HP / 3000 75 HP / 3000 85 HP / 3000 110 HP / 2900 150 HP / 3000 170 HP / 2900 Net Weight (KG) 200 260 300 310 350 400 500 650 Liter Shaft Oil Volume 1. of Bore *Stroke Cylinders (inch) 1 3 4 4 4 4 4 6 6 1.54 3. 45 camshaft. that arranged to allow power take-off through a flexible coupling directly from engines rotating element. 4-Stroke.54 3. pre-piped wired.fabricated.com S E L E C T WI T H . Features & Nothing beat Excel Series packages since allows to fit in to small spaces.sf feco.S K I D PAC KA ◊ S pace Saving Design Efficiency: ◊ E asy to Install & Handle: Excel Series I beam base provide easy lifting slots. ◊ Available in capacities from 50 GPM up to 1500 GPM and pressure range up to 12 BAR. 12 www. ◊ P re. factory tested unit. A G E D ETA IL S & Benefits ◊ I n compliances with local civil defense requirement & NFPA 20 selection & operation procedure. CO N F ID ENCE S F F E C O FIRE PROTECTION ENGINEERS 13 . ◊ D ynamic balanced pumps impellers. ◊ P ump set piping is hydrostatically tested to ensure piping integrity. ◊ P umps coupled with heavy duty trouble free electrical & diesel drivers. . Minimum inlet pressure .Ambient Liquid . • Municipal boosting water supply and pressure a.com .. not cont aining solid p a r t icles. b ) Wh en p u m p in g liquids w it h a highe r density ( or ) v i s c o s it y.-15°C to +90°C Hot Water .-15°C to +120°C • Boiler feed and condensale systems • Washing plants and wash down irrigation and dewatering • Domestic water supply • Cooling water systems • Fire fighting b.ex p los ive liquids . hotels. Check the pump is not and will not be exposed to cavitation Usage: • Pressure boosting in high-rise buildings. n o n .NPSH • Calculation of the inlet pressure “H” is recommended when.Ve r ti ca l M ult s ta i n l e s s st e e l c e Application: T h e G MA X s er ies is a m ultipur pos e pump rang e s u it a b le f o r a va r ie ty of dif f e re nt applications d e ma nd in g relia ble and cos t e f f icie nt s uppl y. H andle s var ious liqu ids from p o r t a b le wat e r to indus tr ial li quids w it hin a ver y wide t e m pe rature . Liquid Temperature: Normal Operating . f low and p res s u re s ca les . etc.sf feco. t he cor re ction f or t he same h a s t o b e d o ne f or capacity. he ad and p ower f a ct o rs . • The liquid temperature is high • The flow is significantly higher than the rated flow • Water is drawn from depths • Water is drawn through long pipes • Inlet confitions are poor Example: 14 www. a ) Th in .Std Design . make s ure t hat t he re is a Electrical Data min imum p res s u re on t he s uction s ide of t he Protection Class: IP55 p u mp . 5 me t ers head. the ca n opera t e a t a s uction lif t of m axim u m “H” motor output (P2) must be reduced due to the low me t e rs h ea d . S F F E C O FIRE PROTECTION ENGINEERS 15 .t is ta g e in-lin e e n t r if u gal pump s To avo id cav it a t io n.Hf .) 3 x 200-277V/380-480V I n c los ed s ys t ems .: 3 x 200-230 / 346-400V 3 x 200-255 / 380-440V ( B a rom e t r ic p res s ure can be s e t to 1 bar. Fan-Cooled. it may be necessary to use a p re ssu re o f m in im um “ H” m e t e rs head is motor with a higher output.H v . 3 x 220-240 / 380-415V 3 x 380-415V Standard Voltage: 60Hz. t he pu mp motor is located 1000 meters above sea level. Motor The motor is Totally Enclosed. an inle t air. In such cases. ( To b e rea d f ro m t he vapor pre s s ure scale. d e live r in g .N PSH .: 3 x 200-220 / 346-380V H = Pb x 10 . ) H v = Va p o r p res s ure in m e t e rs he ad. ( To b e rea d f ro m t he NPSH cur ve at t he highes t f low t he p u m p w i ll be de live r ing. 2 . T h e m a x imum s uction lif t “ H” in me t ers Insulation Class :F h e a d ca n b e ca lculat e d as f ollows Standard Voltage: 50Hz. 2-pole with principal dimensions in accordance with EN standards Electrical tolerances according to EN60034 Motor Protection • Single phase motors have a built in thermal overload switch • Three phase motors must be connected to a motor startyer in accordance with local regulations • Three phase motors from 3kW and upwards have a built-in thermostat (PTC) according to DIN 44 082.Hs Pb = B a ro m e t r ic Pre s s ure in bar. re q u ired . N PSH = N e t Po s itive Suction He ad in me t ers head. ( To b e rea d f ro m t he vapor pre s s ure s cale. density and consequently low cooling effect of the I f t h e “ H” c a lculat e d is ne g ative . ) H f = Fr ict io n lo ss in s uction pipe in me t ers head. Pb indicat e s t he sys t em p re ssu re in b a r. “H v ” d ep en d s o n t he liquid t e m pe rature “ Tm”) Ambient Temperature Maximum +40°C If the ambient temperature exceeds +40°C or if the I f t h e “ H” c a lc u lat e d is pos itive . “H v ” d ep en d s o n t he liquid t e m pe rature” Tm”) H s = S a f e t y m a rgin = minimum 0. (At the h ig h es t f low t he pum p will be c. Ve r ti ca l M ult s ta i n l e s s st e e l c e Model Jockey Pump GVS 4-60 GVS 8-60 GVS 8-120 GVS 16-80 Inch Suction/ Discharge 1¼ 1½ 2” 2” Speed (RPM) 3500 3500 3500 3500 (GPM) 20 50 50 100 Head(m) 70 70 120 120 16 www.sf feco.com . t is ta g e in-lin e e n t r if u gal pump s Material: GVR/GVS Pump head Pump head cover Shaft Base shaft seal Base plate Rubber parts Impeller Chamber Outer sleeve O-ring for outer sleeve Cast iron EN-GJL-200 Stainless steel 304 Stainless steel 304 (or) 316 Stainless steel 304 (or) 316 Mechanical Cast Iron EN-GJL-200 EDPM or FKM Stainless steel 304 (or) 316 Stainless steel 304 (or) 316 Stainless steel 304 (or) 316 EDPM or FKM * Stainless steel on request Pump components can be supplied in ss 304 or ss 316 S F F E C O FIRE PROTECTION ENGINEERS 17 . monitor ing sys t ems l ike BMS OR FAC P. and Joc key pu mps Dr ivers. S F F E CO’s Ex ce l Se r ie s Controlle rs are pre-wired. as well as tu r ns pu mps dr ivers ON/O FF und er s p e cif ic co n d it io ns . T h e Fire Pu m p Pa c kag e Controlle r de t e cts signals t hrough se t of built in switc hes t hat ref l ect t he s ys t e m Pres s u re & Flow s t atus e nabling f ire pu mp pac kag e dr ivers (Electr ical /Diesel /J o c key ) to op era t e in ca s e of pre s s ure in t he s ys t em is lower t han se t point. 18 www. • Lamp t es t f acility (op tional). and m a kes up p u m p s f o r b o t h M anual & Autom atic modes. out door applicati ons (Op tional). • Crank prot ection circuit for diese l eng ine • L ow M a in t en a nce Cos t and available spare (op tional). • S t ai nless S t eel Encl osures are ava ila b le fo r • Au t o m a t i c o r manual ( t e s t) ope ration. Pump Controller Features • S t a n d a rd D r y Run Prot e ction ( above 10 0 • Compatible wit h any remot e sig na ling o r GPM p u m p s ). u p o n req u es t (O p tional) . as well as opera t ing t he S t a n d by d r iver due to powe r f ailure and/or su bs t antial drop in pressu re. • D O L – (B elow 60 HP M otor Size ) / S t ar • Electronic batt er y c harg er (cu r rent sensing ) . • S t a n d a rd ca ble m ar k ing f or easy • S trong. S t andby.com .sf feco. • Fault Tr ip f acility (ot her t han d r y r un • NF PA A r ra n g eme nt / IP s t andard Available op tional). • D if f e ren t M o u nting S ty le s .of f ( tim e r bas e d) ( op tional). D e lt a S t a r t er C ircuit available up on requ es t.F IR E PU M P C O N TR O L L E R S “E x c e l S e ri e s ” Fire Pump Unit Controller is t he Pu mp Pac kag e brain t hat designed to C o nt ro l & Monit o r t h e o pe ration of t he M ain. Powder Coat ed Gal vaniz ed S t eel Enclo sure. • Del ayed s t ar t for f ire si gnal (op tio nal) . Rel iable and Eleg ant S t and a rd Red m a in t en a n ce. • L ow Pres s u re cu t. p a r ts . and f actor y t es t ed before ship m ent and m a d e rea d y f o r imm e diat e us ag e . • Standard up to 250 GPM Skid size. • Standard as common panel for Electrical. • Seperate arrangement is available up on request. • Standard as common panel for Electrical. • Seperate arrangement is not available. Model C • Standard self standing arrangement. • Seperate arrangement is available up on request. • Standard as common panel for Electrical. S F F E C O FIRE PROTECTION ENGINEERS 19 . • Seperate arrangement is available up on request. • Standard up to 750 GPM Skid size. Diesel & Jockey drivers.Model A • Wall & Base mounted arrangement. • Standard as common panel for Electrical. Model D [Optional] • Standard self standing arrangement. Diesel & Jockey drivers. Diesel & Jockey drivers. Diesel & Jockey drivers. Model B • Wall & Base mounted arrangement. • Standard up to 1500 GPM (Star Delta) Skid size. sf feco. The val ves will allow t he wat er t o b e draine d whe n not in use. S o t h at t he re is little pre s s ure drop t hrou gh a g at e val ve. a nd d ang e r of f re e zing exis ts. The t hreads will g e n e ra ll y b e NP T s t andard wit h caps and c hai n Ball Drip Valve Whe n t he hos e he ade r is locat ed ou tsi de. This val ve is used fo r t h rottling t he f low. Val ve opening is same as t he inside dia of p ip e.com . Thu s prevents t he line from breakag e. Bu tt er f l y val ves are for use o nl y in t he d is c harg e as s e mbly. Hose Valve H ose va l ves re UL / F M approve d and are fur nished in t he requ ired q u a n t it y f o r a g ive n f ire pum p s ize by NFPA 2 0 . or at dis t ance from t he p um p. a ball val ve or indicating drain val ve sha ll be lo cat e d in t he pipe line to t he hose header.Gate Valve L is t e d g at e or butt e r f ly val ves are to be u sed when required i n t he sys t em o r a s s how n in t he above ty pical sys t em. in w i nt er d ue to f re e zing. 20 www. we offer a complete line of UL/FM approved flow meter which can adequately test the fire pump performance in cases of liquid water supply. Available in calibrated venture design with a wall or pipe mounted dial meter reading in GPM. S F F E C O FIRE PROTECTION ENGINEERS 21 . The system provides a +/. shall be equipped with a listed main relief valve. Whe n s e t proper l y.Gauges A Suction and discharge gauge is furnished for each fire pump. The venture principle provides a clog-free design and allows the most compact piping arrangement of any other flow meter design. Wit h a minimum dial size of 3 ½ inch. The valves are set to prevent a pressure on the fire protection system greater than it can withstand. Main Relief Valve Pumps which are connected to diesel engine or steam turbine drives. The val ve will have an adju s t able ra ng e w hic h is s e t in t he f ield. Our standard gauges read in psi. Engine dr i ven u nits do not requ ire a ca sing re lie f valve f or whic h wat er is continu ousl y drawn t hrou gh t he pum p f or e ngine heat exc hang er cooling pur pose.1% accuracy. Exhaust Silencer An indus tr ial ex haus t si lencer providing 10 – 15 DBA red uct io n is f ur nis he d w it h eac h di esel unit . in addition to the hose valve header with hose valves. t he val ve per mits enough wat er to d isc ha rg e to a drain to prevent t he pu mp from over heating when r unning a t conditions near shutof f. or. The main relief valves are also used when the shut off pressure plus the static suction pressure exceeds the rated system pressure. Spring loaded and pilot operated types are available in UL-FM Design. t he pressure range shall be twice t he working pressure of the pump wit h a minimum of 200 psi. Th e c o n n ect o r relieve s t he r m al expans io n s trains and helps dampen t ra n smi t t ed en g in e v ibration. ot her g rades are availab le t o suit indiv idual job requirements Flow Meter System In place of. have a range of 300 psi and are compound pressure and vacuum type. when installed properly. Flexible Exhaust Connectors A f lexib le co n n ector is prov ide d at t he ex haus t ou t le t of t he engine. Casing Relief Valve T he cas ing relief val ve provides a vit al function on electr ic d r iven units . The main relief valve size shall be greater than or equal to the values given in NFPA 20. and as needed for any given layout.com . A listed check valve is furnished in the piping arrangement as shown. They are extremely effective in preventing back pressure or back flow features a low 0. the suction and discharge connections will be match the NFPA 20 minimum values. Since our fire pumps have been disigned specifically for fire pumps usage. The piping size may be different that the pump suction size necessitating the need for an eccentric reducer. Concentric Discharge Increaser The discharge pipe size shall not be less than the values given by NFPA20. Enclosed Waste Cone The enclosed or open waste cone is connected directly to the main relief valve and provides a visual indication of the water discharging through the line. saving cost and installation time. absolute.5 psi (0. but not less than the minimum values given by NFPA 20. The fitting also increases the line size from the relief valve as required by NFPA 20. The minimum size is a ½ inch inlet and the valve is installed at the top of the pump volute. hose header line. The valve is not required in self venting end suction pump.Eccentric Suction Reducer The suction piping is sized such that the NPSH available will be greater that 19 ft. when operating at 150% of the rated capacity. when there is a need for reducer or increaser a fitting is eliminated. Check Valve 22 www.03Box) cracking pressure differential and are capable of handling pressure to 275 psi (19 bar). Automatic Air Release Valve The automatic air release valve releases air that may accumulate in the volute of the horizontal split case pumps. An eccentric fitting is used to prevent the possibility of air pockets forming in the line as would be experienced if a concentric fitting were used. 90 deg Elbow Standard 90° elbows are required in the piping arrangement as shown for the main relief valve drain. These values are generally different than the pump discharge size and hence the need for an increasing or redusing or reducing fitting. The enclosed cone is provided with a sight glass. Which reduces pressure loss in the line by avoiding turbulence in the flow. In most cases.sf feco. O R DER ING I N F O R M ATI O N S F F E C O FIRE PROTECTION ENGINEERS 23 . Dammam – 31462.Riyadh 14334 Tel.com. Dubai U.A. 00966 1 2650070 .Al-Kharj Road .O.com.sa Madina – Sultana Branch: Tel: 048660959 / 048283256.E.com.O. Fax: +966 2 676 0307 E-mail: [email protected] Jeddah Branch: P.sa Bahrain Branch: Telefax: +973 17 721153 E-mail: bahrain@sffeco. KSA Tel: +966 2 670 6009. Fax: +966 3 8351968 E-mail: [email protected] : [email protected] Office: 2nd Industrial Area .O. Box 16769. Fax: 048660969 E-mail: madinah@sffeco. Tel: +971 4 880 9697. Box 7162.sa Dubai International Sales Office: Jebel Ali Free Zone.Fax.# 2/11 .Riyadh . 00966 1 2652190 P. Box 4441 . Jeddah – 21474. KSA Tel: +966 3 8351961. Fax: +971 4 880 9245 Rev.sa Dammam Branch: P.
Copyright © 2024 DOKUMEN.SITE Inc.