SERVOMEX - 2210 and 2213 Control Unit

June 11, 2018 | Author: Manuel Marin | Category: Relay, Electromagnetic Compatibility, Electronic Engineering, Manufactured Goods, Technology


Comments



Description

2210 and 2213 Control Unit forServomex 2200 Process Oxygen Solution The 2210 and 2213 control units are designed to work with the 2223 oxygen transmitter. The graphical user interface allows for simple operation and has multi-language capability as standard. • Controls up to six Transmitters simultaneously • Certified for hazardous areas, flammable dusts and flammable gases • Explosion proof design means no instrument purge required • Simple two wire digital connection for ease of installation • Digital Communications Enabled as Standard Hazardous Area Approvals: ATEX Category 2 and ATEX Category 3 FM Class I, Division 1 and FM Class I, Division 2 CSA Class I, Division 1 and CSA Class I, Division 2 TIIS Zone 1 IECEx Zone 1 and Zone 2 The control unit provides full access to set up functions such as, auto-calibration, alarms, relays and faults. A full set of diagnostics information is available that can be used to assist with predictive maintenance. The unit is compliant with the requirements of NAMUR. FEATURES Control Unit Digital Output STANDARD: Graphics LCD display with LED backlight and integral keypad (seven button). Two “low power” relays rated 30Vac/dc @ 1.002% of output span Eight digital inputs per option card. customer assignable. customer assignable to Namur status alarms. Potential use: 0. EC DIRECTIVE COMPLIANCE The 2210 and 2213 Control Units comply with the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC (as amended by Directive 92/31/EEC). both as amended by Directive 93/68/EEC. This product is rated for “Installation Category II” in accordance with IEC 664. fault or auto-calibration functions. This product is rated for “Pollution Degree 2” in accordance with IEC 664. The user may define a second range and invoke it by means of an external contact closure. The ‘Modbus’® Digital Communications Protocol is provided as standard.2 psia) Warm up time: Useable immediately.001% oxygen PHYSICAL IP Rating: Mounting: EXTERNAL INTERFACES CARDS Digital Input Card IP66 (NEMA 4X) Wall Mounted AMBIENT CONDITIONS Temperature: Operating:-10 to 50°C (14°F to 122°F) in sheltered location Storage: -20 to 70°C (-4°F to 158°F) Atmospheric Pressure: 76 to 112 kPaa (11 to 16. The analyser comes with “password protection” as standard. ® ‘Modbus’ is a trade mark of AEG-MODICON COMMUNICATION with Servomex 2223 Transmitter Communications between various elements of the 2200 analyser will utilise a digital RS485 based system running a Servomex protocol. customer assignable to ‘Namur’ status alarms.EMC requirements (All induced errors are less than the intrinsic error). 50/60Hz. Auto-calibration software as standard (operation will need one of the relay option cards). alarm. any of the following may be fitted in to each slot: mA Output Board: Two mA outputs and two “low power” relays per card Relay Board: Four “high power” relays per card Digital Input Board: Eight digital inputs per card. Maximum impedance for each output is 1K.0 Amp. control and laboratory use . control and laboratory use. auto-calibration or remote range change functions. alarm. . PERFORMANCE See the relevant Transmitter Technical Data Sheet for the performance specification Output resolution: display Control Unit mA Outputs: whichever is the greater: 0. Digital Communications ‘enabled’ with Modbus protocol as standard. The connection is via a single intrinsically safe twisted pair. OPTIONAL: Four option slots exist. 40VA. Please consult Servomex for the maximum separation between multiple transmitters and a single control unit. The maximum separation between a single transmitter and control unit is 1000m.0Amp. The mA output can be made to “Jam” high or low on a fault condition in accordance with Namur 43.001% oxygen or 0.SPECIFICATIONS Power Supply: 100-120V or 220-240V ac. EN 61326-1: Electrical equipment for measurement. They conform to the following harmonised European standards for product safety and electromagnetic compatibility: EN 61010-1: Safety requirements for electrical equipment for measurement. but typically 2 hours from cold start at 20°C Autocalibration initiation Remote range change Validity of mA inputs Digital flow sensors Analogue Output Card Two isolated 0-20mA/4-20mA outputs with full configuration of zero and span. Other protocols available on request. All outputs may be configured in ‘reverse’ and the maximum current for all outputs is 21. Relay Outputs/Alarms Card Relative Humidity: 0-95% non-condensing Four “high power” relays per ‘relay’ option card rated at 240Vac/30Vdc @ 1. French and German languages) The ability to connect up to six transmitters to a single control unit.5 mA. Software has multi-language capability (English. C and D Class II.B.F. Class I. Division 1. ambient temperature 50°C maximum Class I. IIC T4 (Ta = 50°C) with IS outputs Ex nCL ia IIC T4 (-20°C ≤ Ta ≤ +50°C) DIP A21 TA 70°C 10kg (22lbs) FM (USA) FM Zones (USA) CSA (Canada) CSA Zones (Canada) TIIS (Japan) IECEx (other) Weight: Ex II 2GD EEx ia d IIC T4 (-20°C < Ta <50°C) Class I.G T4. Ambient temperature 50°C max. T4. Class I. T4 (Ta = 50°C) Ex ia d IIC T4 Ex d ia IIC T4 (-20°C ≤ Ta ≤ +50°C) DIP A21 TA 70°C 25kg (55lbs) 2210 Control Unit (ATEX Category 3) DIMENSIONS SHOWN IN MILLIMETRES 11 236 290 178 266 12 51 11 478 280 478 280 2213 Control Unit (ATEX Category 2) DIMENSIONS SHOWN IN MILLIMETRES 236. T4.2210 Control Unit Hazardous Area Approvals 2213 Control Unit Hazardous Area Approvals ATEX (Europe) ATEX (Europe) FM (USA) FM Zones (USA) CSA (Canada) CSA Zones (Canada) IECEx (other) Weight: Ex II 3GD EEx nC(ia) IIC T4 (-20°C < Ta <50°C) Class I. Zone 1 AEx d ia (ia IIC) IIB + H2 T4 Ambient temperature 50°C max.B. Zone 2 IIC T4 Ambient temperature 50°C max. Division 2.12 222. Ex d ia (ia) IIB + H2. Groups A.12 490 315 250 275 230 Ø290 . ambient temperature 50°C maximum Class I. Class I.Groups E. II & III.C. Class I. II & III. Zone 2 approval. Division 2.F.G T4.C and D Class II. Groups E.C.E. Division 1 Groups B. Division 2 Groups A.D.F and G Class III Type 4X.Groups B.D. Ambient temperature 50°C max. Zone 1 approval. Division 1.F and G Class III Type 4X. UAE. Chiyoda-ku. 1F JP Kaji-cho Bldg. Stephensonstraat 20. Certificate No.. No. stability and repeatability • Certified for hazardous areas. Taipei.com for technical data sheets.servomex. flammable dust and flammable gases • Compliant with the requirements of NAMUR • Simple transmitter only operation or in conjunction with control unit Hazardous Area Approvals: ATEX Category 2 CENELEC Zone 1 FM Class I. YOUR NEAREST CONTACT IS: Visit www. • Servomex oxygen specific._________Q05166 BS EN ISO 9001 Servomex Group Limited. Division 1 TIIS Zone 1 IECEx Zone 1 www. 8 Rue Proudhon.88 Lane 2888 Hua Ning Road. application and technology information for all Servomex analysers. France Servomex GmbH. 525 Julie Rivers. Sec. Münsterstraße 5. 6 05/05 E .88.Ltd. AGENTS AND REPRESENTATIVES ARE LOCATED THROUGHOUT THE WORLD.P. Japan (44) 1892 652181 (31) 79-346 42 42 (33) 1 49 46 22 50 (49) 23 81 68 82 13 (1) 281-295-5800 (886) 2-2833 8848 (971) 6 557 0303 Fax (44) 1892 662253 Fax (31) 79-342 08 19 Fax (33) 1 49 46 22 51 Fax (49) 23 81 68 81 75 Fax (1) 281-295-5899 Fax (886) 2-2833 8844 Fax (971) 6 557 1242 (86) 21 6442 6488 (81) 3 3255 8162 Fax (86) 21 6442 6498 Fax (81) 3 3255 8154 Global email: [email protected] 101-0045. All rights reserved. 6.. Netherlands Servomex S. Jarvis Brook.. TDS2210/13 Rev. Servomex Asia Pacific Ltd. Servomex has a policy of constant product improvement and therefore reserves the right to change specifications without notice. B.2223 Transmitter for Servomex 2200 Oxygen Analyser The 2223 paramagnetic oxygen transmitter is specifically designed for high performance measurements in the process industry. 7F. Rd.V. Shanghai 201108 PR China Servomex Japan.com SERVOMEX COMPANIES. Servomex Asia Pacific Ltd. (Spectris Instrumentation and Systems (Shanghai) Ltd) Building 9. 93212 St Denis La Plaine Cedex. PO Box 8962. Executive Suites Z1-56..com © Servomex Group Limited. Shanghai Euromate Industrial Park. Crowborough. 2005. reliability. TN6 3DU. Xingzhuang Industrial Park. Germany Servomex Company Inc.. A Spectris company. Chung Shan N. SAIF Zone. 50. field proven paramagnetic technology • Unrivalled accuracy. Taiwan Servomex Group Limited. Division 1 CSA Class I.servomex. No.A. East Sussex. 59065 Hamm. Sugar Land. England Servomex B. 2723 RN Zoetermeer. Texas 77478-2847. Sharjah.. Spectris Co.. 3-5-2 Kandakaji-cho. Suite 185. USA.
Copyright © 2024 DOKUMEN.SITE Inc.