Seaplus Fire Fighting Systems

March 26, 2018 | Author: Yetkin Erdoğan | Category: Fire Sprinkler System, Firefighting, Carbon Dioxide, Foam, Water


Comments



Description

http://www.sea-plus.co.kr Fire Fighting Systems and Equipments Fire Fighting Systems and Equipments Go with SEAPLUS for your safety of fire extinguishing systems, equipments, and others Go with SEAPLUS f o r your safety of fire extinguishing systems, equipments, and others SEAPLUS for your safety life - 2Page 3Page .Fire Fighting Systems and Equipments Index Introduction Company history External fire fighting system Water mist fire extinguishing system High expansion foam fire extinguishing system Deck foam fire extinguishing system High pressure CO2 fire extinguishing system Low pressure CO2 fire extinguishing system Dry chemical powder fire extinguishing system Automatic sprinkler fire extinguishing system Fire detection & alarm system Loose fire fighting equipment Quality certification Total fire test shop World wide a/s net work Plant project team 04Page 05Page 06~07Page 08~09Page 10Page 11Page 12Page 13Page 14Page 15Page 16Page 17Page 18Page 19Page 20~21Page 22~23Page SEAPLUS for your safety life . GO with SEAPLUS for your safety of fire extinguishing systems and equipments.4Page . SEAPLUS for your safety life . Incorporated as "SEAPLUS CO. is one of leaders and manufacturers for fire fighting systems & safety equipment in Korea and we have taken our expertise & experience into the world wide market to establish a reputation for excellence and customer support.1165 Selected as "Leading Enterprise in Strategic Industry" by Busan city Chosen as Promising Enterprise by WOORI BANK Developed Self-rotation type high expansion foam generator Established 2nd manufacturing factory Superiority Business man Awarding by Busan city Awarded the Prime Minister Acquisition for license of Fire protection system design by Busan city Awarded "Commendation for Genuine S/W User" by Minister of Culture. our prospective client. Company history 1994 1997 1999 1999 2000 2001 2001 2002 2002 2002 2003 2004 2006 2006 2007 2007 2008 2008 2008 2008 2008 7 4 7 9 4 4 6 5 6 7 9 12 10 12 8 10 7 7 10 11 12 Established DAE KYEONG Engineering Co.913 Certified as technology-innovating SME (INNO-BIZ) business by Small & Medium Business Administration Awarded Presidential citation Awarded Advance Idea Man (New Knowledge Man) Developed Total Application Water mist fire extinguishing system in According with MSC Circ.. We are confident that you will find our presentation of interest and assure you of our competence and desire to realize your contract in away totally satisfactory to you. LTD.5Page . Sports and Tourism SEAPLUS for your safety life .SEAPLUS for your safety life Introduction SEAPLUS CO. Approved by KITA Established Total fire test shop Designated as Venture Business Developed Local fire fighting system in According with MSC Circ. LTD.." Acquisition for license of Fire protection system construction by Busan city Certified ISO 9001 by KOREAN REGISTER of SHIPPING Moved the factory & office to NOKSAN industrial complex Technical R & D Lab. Tower's characteristic is to be folded and storaged in a low and compact size. m /h Total capacity. portable controller and fire monitor and so on. folding tower and platform on wheel house. It is equipped with fire monitor. Controller Fire Pump Unit . According to mounting location of fire monitor. 3) Fuel oil capacity is to include provisions for continuous operation of all monitors in addition to the total capacity of the vessel's fuel oil tanks required for continuous fire fighting operation. Fire fighting pump can be driven by transmission power from driven-engine or dedicated motor. m Fuel oil capacity In fire fighting system. electric motor.1. fire fighting pump. the external fire fighting system is to extinguish and suppress fires against external vessel. See also 5-9-2/5. m3/h Height.400 120 45 4 4 24 1) Range : measured horizontally from the monitor outlet to the mean impact area. 2006) Class 3 2. 2) Height : minimum height of the trajectory of water monitor jet measured vertically from sea level assuming a mean impact area located at a horizontal distance not less than 70m from the nearest part of the fire fighting vessel.200 1-2 2. It would significant facilitate handling on fire suppression and extinguishing using dual monitor of foam liquid and dry powder.600 150 70 10 10 96 Number of water monitors Discharge rate per monitor. there are sliding tower. monitor.SEAPLUS for your safety life .200 150 70 8 8 96 4 1. m Number of hose connection each side of vessel Number of fireman's outfits 1.6Page SEAPLUS for your safety life Class Notation Number of pumps Monitor range. External Fire Fighting System Water monitor system capacity Class 2 3 (ABS Rule 5-9-1/Table.800 Class 4 2.400 2-4 7.400 2-4 9. 000 ~ 11.400 2.000 680 ~ 1.7Page .000 ~ 40.000 40.000 ~ 60.333 ~ 25.000 ~ 8.333 ~ 20.000 8.333 m3/h 30 ~ 90 90 ~ 180 180 ~ 300 300 ~ 480 480 ~ 680 Actuating Method Electric Electric Electric Electric Electric Electric Electric Electric Electric Electric Electric Electro-Hydraulic Electro-Hydraulic Electro-Hydraulic Electro-Hydraulic Remark Double Gun 11.000 680 ~ 1.500 1.Model FE-65 FE-80 FE-100 FE-125 FE-150 FE-200 FE-200D SFE-200 SFE-200S SFE-200D SFE-200DS FEH-200 FEH-200D FEH-250 FEH-300 Capacity L/min 500 ~ 1.600 Discharge of Fire Monitor Sliding Tower Portable Controller Folding Tower SEAPLUS for your safety life .000 ~ 5.000 25.000 5.500 ~ 3.200 Double Gun Double Gun Double Gun 11.500 ~ 2.400 ~ 3.000 3.500 1. vaporization effect gets increased as much as surface area expansion. audible and visible alarms are provided in the protected space. Especially.SEAPLUS for your safety life . water is sprayed in high or low pressure to make small water droplets. using fire alarm system by detecting fire automatically. the water mist system is to suppress and fight all fires in protected areas. after fire happens. In this fire extinguishing system. engine. And water is discharged into fire area through nozzle to extinguish it. in case of local application.8Page SEAPLUS for your safety life Using spraying water in all fires. incinerator and purifiers as protected area respectively. water mist pump shall be runned. it is designed and installed to cover main engine. During spraying water. boiler. The arrangements of nozzle will be provided according to capacity of nozzle in relevant protected area. Extinguishing effect becomes increased by cooling. The system has two types of local fire fighting system and total fire fighting system. aux. Water Mist Fire Extinguishing System Water Mist Controller Water Mist Skid(Low) Water Mist Controller Water Mist Skid(High) Local Operating Box . In case UMA. Using water droplets. Water mist is sprayed into flame so that to promote vaporization and decrease in oxygen concentration as suffocation. 0 5. Height Projection Vertical Downward Vertical Downward 1.5 0.5 2.6 3.62LPM) 0.0 0. Height Projection Vertical Downward Inclined angle (30~60 form vertical) Side Shooting 4.6~44LPM) Installation (m) Spacing Min.5 K-Factor (Flow rate) 4. Height Max.4(tip to tip) Max. 7.0 3.0 8.0 8.3 Above Doorway 2.6~11.0LPM) Installation (m) Spacing Min.0 - SEAPLUS for your safety life -9Page .6~11.5 (14.0 Max.2~15.2~15. 0.0 4.46 (3.0 3.46 (3.5 (14.5 17.5 (10. Height Projection Vertical Downward 4.56LPM) 3. Height Projection Vertical Downward Vertical Downward 1.6LPM) 1.5 0.0LPM) Installation (m) Spacing Min.0 Total Application System Model : SPF-1C (Accomodation) Working Pressure (bar) 50 ~ 60 90 ~ 100 K-Factor (Flow rate) 1.2 Bilge plate mounted 0.5 2.5 0. Height Max.21 (1. distance to wall Projection Vertical Downward Celling nozzle SPF-2 Bilge nozzle SPF-2 Doorway nozzle SPF-2D 0.76 (13LPM) Installation (m) Spacing Min.0 Model : SPF-3 Working Pressure (bar) Min.0 8. Height Max.6LPM) 1.56LPM) 4.65 (10. 1.0 Model : SPF-2 (Engine Room) Nozzle Model Working K-Factor Pressure (bar) (Flow rate) 60 Installation (m) Spacing Location Max.Local Application System Model : SPF-1 Working Pressure (bar) 50 ~ 60 90 ~ 100 K-Factor (Flow rate) 1.0 0. Height Max.5 (10.5 below Celling 0.6 3.6 3.2 3.0 Model : HSN-510 Working Pressure (bar) 40 ~ 90 K-Factor (Flow rate) 1. High expansion foam system has been extensively full scale tested for fires in machinery spaces. fire fighting can immediately begin by the user of high expansion foam system and there is a further advantage of reduced damage due to the cooling effect created by the water and the foam on surfaces.0 Weight (kg) 4 7 10 SPECIFICATION 1) High Expansion Foam Concentrate : Meteor P +. An inert atmosphere is created and the fire is extinguished.for your safety life SEAPLUS for your safety life . Foam fills all the voids and seals the fire from the air supply. high expansion foam system is good replacement. following IMO guidelines.10Page SEAPLUS High Expansion Foam Fire extinguishing system High expansion foam system is used as alternative system of Halon extinguishing system. Skum 2) Mixing Ratio : 2% (Foam Concentrate) + 98% (Water) 3) High Expansion Foam Generator .5 55. When installing high expansion foam system there is no need for large air ducts or unnatural hull opening to produce foam. and steam absorbs heat energy when water is vaporized. 2&3. It is also excellent alternative system of CO2 and sprinkler systems. simplified piping system and low weight generators in combination with seaplus traditionally and well proven foam central unit makes the whole system easy to install. class 1. The system is manually operated but may be supplied upon request with remote operation. When a fire occurs. High expansion foam system is suitable for installation in engine room together with adjacent spaces as local and /or total flooding. High expansion foam system extinguishes fires with a combination of water and foam. As halon replacement being phased out due to environmental reasons. Foam Generator Certification Proportioner High Expansion Foam Generator Model SPHG-30 SPHG-60 SPHG-90 V : Vertical downward H : Horizontal Expansion Ratio(Times) V 880 / H 877 0.0 37.4 V 877 / H 874 V 874 / H 877 JIS10K-25A Flange Foam Solution Foam Capacity Working Flow rate(LPM) Pressure(Mpa) (m3/min) 32 75 110 >28 >65 >96 Connection Method K-Factor 16. 80 FM .000 20.000 13.150W 80F .125 Capacity (LPM) 500 ~ 1.000 ~ 8.11Page .000 Connection Size Water Side Foam Side JIS10K-100A JIS10K-150A JIS10K-200A JIS10K-250A JIS10K-50A JIS10K-50A JIS10K-80A JIS10K-80A Foam Monitor Model Foam Hose Box FM . Calculated and designed in accordance with international regulations.250W Max.000 5.100W 50F .100 FM .500 1.500 ~ 3.200W 80F .Deck Foam Fire extinguishing system Foam system for the protection of chemical and oil tank decks or heli-decks in accordance with class requirements and IBC code.000 6. Foam Tank Unit Balanced Pressure mixer Foam Proportioner Model 50F .000 3.65 FM .000 Connection Size JIS10K-65A JIS10K-80A JIS10K-100A JIS10K-125A Foam Monitor SEAPLUS for your safety life .000 ~ 5. Water Flow Rate (LPM) 3. The foam monitors may be delivered as manually operated (electric or hydraulic type). 12Page SEAPLUS High Pressure CO2 Fire extinguishing system Carbon Dioxide(CO2) Gas. and pipe lines connecting these main parts. the fastest and most efficient extinguishing agent against fires in protected spaces. the fastest and most efficient extinguishing agent against fires in protected spaces. Master Control Cabinet Cylinder Valve Pressure Operating Distribution Valve(1”~6”) . The system is to be designed by the required discharging time. suffocates the fire within designated time and minimize the damage in protected spaces. CO2 gas. main isolating valve(s). manifold. suffocates the fire within designated time and minimize the damage in protected spaces.for your safety life SEAPLUS for your safety life . The system consists essentially of CO2 cylinders. a smoke detection system can be combined with the CO2 system. The Fire Extinguishing System extinguishes the fire by means of CO2 gas. CO2 nozzles in compartment protected space. CO2 cylinders quantity and which are stored in a independent CO2 room. For further security in ship's cargo holds. The tank unit is furnished with its own refrigeration machinery to keep the temperature and also to adjust the pressure at the correct level.Low Pressure CO2 Fire extinguishing system The required quantity of CO2 gas is stored in one or two large tank. the required quantity of CO2 gas is adjusted by timer which is installed at relevant valve control cabinet. The system is designed and installed so that CO2 gas can be discharged into relevant protected area using valve control cabinet. Pressure CO2 Storage Tank Instrument Control Panel Safety Valve 15~25mm(1/2”~1”) Safety Valve 3~300mm(1/8”~12”) Double Stop Valve 15~32mm(1/2”~1-1/4”) Refrigerator SEAPLUS for your safety life .13Page . At that moment. 5 Shooting Length (m) 10 18 23 30 5 ~ 10 Monitor Hand Hose Gun .for your safety life SEAPLUS for your safety life .14Page SEAPLUS Dry Chemical Powder Fire extinguishing system The SEAPLUS dry powder system is designed specifically for marine application so that can be met with SOLAS requirements for LPG and LNG tankers. Dry Chemical Powder Gun Pneumatic Control Cabinet Hose Station Box Dry Chemical Powder Skid Model Flow Rate (kg/sec) 10 16 20 25 3. 15Page . the sprinkler pumps can be operated form the ship's main and emergency switchboard. Statistics estimates that about 70% of all fires has been extinguishing by less than three sprinkler heads. at a constant pressure level. posing no threat to passenger and crew.Automatic Sprinkler Fire extinguishing system This system is installed in accommodation spaces and other service on the vessels such as passenger ships and car ferries. When sprinkler nozzles are actuated. The sprinkler pressure tank contains fresh water. Operation of sprinkler-system Immediately after fire breaks out in a protected area. The sprinkler system is the most effective at its early stage in extinguishing fire. As soon as the ambient temperature has reached the set release temperature. the glass bulb bursts and the sprinkler is activated. which being discharged into protected area. the sprinkler system is activated resulting in a pressure drop in the sprinkler storage tank. For safety reasons. the intense heat rises rapidly under ceiling zone. Water supply is provided with adequate pressure by dedicated pump set which is arranged to start automatically when the pressure falls down below set point of the pump's start-up relay. The sea ensures an inexhaustible supply as fire extinguishing agents. Sprinkler Nozzle Release Sprinkler Heads Sprinkler Central Panel Nozzle Escutcheons SEAPLUS for your safety life . Fire detection Fire Alarm Control Panet (JB-QB-4508) -4 Loops / 508 Addressable Detectors Fire Alarm Repeater (JB-QB-4508R) Heat Detector Smoke Detector Infra Red Type Flame Detector Manual Call Point Isolator Alarm system Fire Alarm Controller Fire Alarm Repeater Flame Detector Manual Call Point Smoke Detector Isolator .SEAPLUS for your safety life . repeater and alarm device and so on. Upon the receipt of fire and fault signals. control panel.16Page SEAPLUS for your safety life Heat Detector The fire detection and alarm system consists of fire detectors. manual call point. alarm device and VDR with audible and visible alarm as well as indicate fire and fault signals on LCD of fire alarm panel with audible alarm. fire alarm system shall send relevant signals to alarm monitoring. 17Page .5kg Dry Powder Fire Extinguisher (Portable Type) 45L Foam 135L Foam Fire Extinguisher (Wheel Type) Portable Foam Applicator Assembly Sea water Fire Fighting Equipments Fire Hose Rack Fire Hose Box Fire Hose Reel Spanner International Shore Connection Fire Hose With Coupling Jet / Spray Nozzle SEAPLUS for your safety life .Loose Fire Fighting Equipment Fire Man’s Outfit Equipments Fire Suit Air Breathing Apparatus Fire Axe With Beit and Life Line Safety Lamp Fire Extinguisher 9L Foam 6.8kg CO2 6. 18Page .Quality Certification SEAPLUS for your safety life . 750 m3 Anti-Fire Block & Anti-Fire Foam Total Fire Test Area : Machinery Area / Control & Monitoring Room Control & Monitoring System Remote Control for : Monitoring & Recording Pump. Flow.000 m3 for large ship) 35 m 11 m 12 m 3.SEAPLUS for your safety life Total Fire Test Shop Scales Specification Length Breadth Height Volume Material Major Zone Division IMO Circ.O.668 CLASS III (Above 3. Spray Nozzle Test Shop Atmosphere All Data Analysis System Data Saving on Computer & Print O2 Concentration Analysis Equipment What Fi-Fi System can test ? CO2 System Low Expansion Foam System High Expansion Foam System Dry Chemical Powder System Water Mist System Water Spray System Smoke Sampling System Fire Detection System Sprinkler System Portable Extinguisher Other Water Based Fi-Fi System What Kind of fire can test ? Oil Spray Fire High Pressure (150 bar) Low Pressure (7 bar) Engine Mock-Up Pool Fire Class A Fire Cabin. Valves Agent Flow & Pressure F. Corridor & Public Space Fire (Future) SEAPLUS for your safety life .O.19Page . Pressure & Temperature Test Shop Atmosphere Temperature Engine Mock-Up Temperature F. Cape Town. Barcelona . El Harlem.Miami.Lieto .T. California. Puxeiros-Mos-Vigo.Tallinn .Hafnafjordur .Lokeren . Vitrilles .Kwai Chung. Bremerhaven .20Page .Tuzla/Istanbul . Messina .WORLD WIDE A/S NET WORK SEAPLUS makes the future with the challenge to a new world and unswerving R & D efforts.Dubai . Cape Canaveral.Esbjerg .Johor Darul Takzim . You shall be assured of our efforts for the world-highest precision and quality. Delfzijl .Hamburg. Jan Nikolaj Jensen TEL : +45 76 118100. VIKING LIFE-SAVING EQUIPMENT A/S (HEAD OFFICE) Saedding Ringvej 13 6710 Esbjerg V Denmark CONTACT : Mr. Durban . La Spezia.Napoli. Oslo.Montivilliers. N. FAX : +45 76 118101 [ SEAPLUS share the following world-wide service station with VIKING A/S] USA FRANCE NORWAY TURKEY FINLAND RUSSIA SWEDEN ESTONIA UAE SPAIN SOUTH AFRICA ICELAND NETHERLANDS BELGIUM ITALY SINGAPORE MALAYSIA DENMARK GERMANY HONG KONG . SEAPLUS for your safety life .Stockholm . Avladsnes. Washington .Cadiz.LX Zwijndrecht.Petersburg . Alesund .Straume. No. 834437 Taksim Istanbul. Desmond Goh TEL : +65 6549 5111.net.E MAXELL INTERNATIONAL L. Merijn Struijs GANI SHIP SPARE LTD TEL : +49 (0) 4352 20 48 911.H BRENNAN & CO PTE. 794-0025. Singapore 508739 NETHERLAND MK-MARINE GMBH Inglasco Fire System B.com CONTACT : Mr. PAI TEL : +971 4 2676128. Gounderakstraat 22. 307 DB Rotterdam. Taiwan. FAX : +86 21 6329 3888 E-MAIL : gus_hou@haicheung. China SINGAPORE W. (HK) LTD Shanghai Representative office 8/F. Japan FIREFLY Am Redder 1 22941 Bargteheide.S. FAX : +49 471 97227 27 E-MAIL : [email protected] CONTACT : Mr. Ehime.217.tr TAIWAN PILOT MARINE TECHNOLOGY & ENGINEERING CO. Taisho-cho 6-Chome.jp CONTACT : Mr. FAX : +90 212 293 4478 E-MAIL : gani-nb@gani. Shanghai. 1 mabari. DUBAI. J.Ltd. Sinem SANDIKCI TEL : +90 212 293 4477.eu CONTACT : Ms.Choi TEL : +86 21 5422 4157. Gus Hou TEL : +86 21 6888 9889.ae JAPAN PRO-TECH Co. 1200 Pudong Avenue. and others CHINA OCEAN MARINE SERVICE CO. FAX : +866 7 8211571 E-MAIL : [email protected] with SEAPLUS f o r your safety of fire extinguishinh systems. Minhang Qi. FAX : +81 898 23 2078 E-Mail : h-kumazawa@protech-i. No. Chuan Cheng Dist. Bremerhaven. eguipments. 1-6.E CONTACT : Mr. FAX : +31 10 479 2355 E-MAIL : info@inglasco. Hsing Sheng Road. Johny Wan TEL : +886 7 8211545.net CONTACT : Mr. Netherlands CONTACT : Mr.21Page .O.. China.net SEAPLUS for your safety life .hinet. LTD No. Kaohsiung. FAX : +86 21 5422 4156 E-MAIL : jgchoi777@dreamwiz. 1100 Wuzhong Road.O BOX 47620. John Fongers TEL : +31 10 479 3611.G. U.C P.A. Ju Yang Tower. Germany TURKEY CONTACT : Mr.L. R. FAX : +49 (0) 4352 20 48 920 Gumussuyu Mah. D-27572.nl HAI CHEUNG TRADING CO.. Shanghai.struijs@fire-fly. Kutlu Sok. FAX : +971 4 2676129 E-MAIL : [email protected] CONTACT : Mr. Turkey E-MAIL : merijn.V.. N.LTD. Werner Oltersdorf TEL : +49 471 97227 13.com. Hiroki Kumazawa TEL : +81 898 23 2051.A. 47 Loyang Way. CONTACT : Mr. Germany U. 200135 GERMANY MK-MARINE GMBH Werner Oltersdorf Westkai 50. LTD. FAX : +65 6542 5246 E-MAIL : demond@whbrennan. No. WATER SPRAY SYSTEM .SEAPLUS for your safety life -22Page SEAPLUS Plant Project Team DESIGN & CONSTRUCTION for FIRE FIGHTING SYSTEM of PLANT PROJECT Seaplus’s Plant project team consists of specialists for mechanics.CLEAN AGENT SYSTEM .HYDRANT SYSTEM FIRE ALARM & FIRE DETECTION SYSTEM KDX-III DELUGE & SPRINKLER SYSTEM . thermodynamics and fluid mechanics based fire fighting system. Plant project team has delivered to all Korean thermal power plant a fire fighting system & fire alarm and fire detection system for parts of bulk material handling system and boiler system after 2003 year. We accepted an order for the fire fighting system of Cuba DPP project and the service gas supply system of Bahrain IWPP project recently. electronics.SPRINKLER SYSTEM .CO2 SYSTEM . We have licenses for fire fighting design and construction approved by Korean government. Plant Project Team FIRE FIGHTING SYSTEM .WATER SPRAY SYSTEM .FOAM SYSTEM .DRY CHEMICAL SYSTEM . Hydrogen (H2) gas system is used as a coolant for the main steam turbine or generators. It is designed for use in a variety of special hazards applications including flammable and combustible liquid hazards. Nitrogen (N2) gas system shall be to blanket the steam and water line in order to prevent corrosion during long term wet lay up.Seaplus plant project team plans. transformers and turbines. Plusgun dust suppression system consists of the PLC based control system and a shooting gun which spray water on the ground uniformly. from nozzles having predetermined patterns to completely impinge water onto the hazard surface being protected. coke and scrap iron etc or inside chute and skirt in transfer tower. Carbon Dioxide (CO2) gas system is used for purging the air and other gases in pipe system. Plus dust suppression system is focused on developing intelligent solutions for the flying ash at raw material storage area like as coal. return belt washing and water spray system. SEAPLUS for your safety life . designs. Return belt washing system for protect to stack a raw material on the floor in gallery or girder is applied to bulk material handling system. manufactures and supplies a full range of proprietary products for dust suppression. SERIVCE GAS SUPPLY SYSTEM Service gas system applied to steam power generator. PLUS GUN DUST SUPPRESSION SYSTEM PLC BASED CONTROL SYSTEM WATER SPRAY SYSTEM Water spray system is designed to direct water at a required density.23Page . co.co. 200905 Vol. 1 . SongJeong-Dong GangSeo-gu Busan Korea +82-51-831-0119 +82-51-831-1119 Domestic /[email protected] Rev.kr http://www.kr Overseas /[email protected] TEL FAX E-mail 1575-3.co.kr A/S /[email protected] Plant /[email protected]. No.co.
Copyright © 2024 DOKUMEN.SITE Inc.