Ruud Package Unit 12.5 Ton

March 26, 2018 | Author: Emir Revilla | Category: Air Conditioning, Hvac, Mechanical Fan, Gas Compressor, Electromechanical Engineering


Comments



Description

Package Air ConditionerRLNL-B Series Ruud Commercial Achiever ®® Series Package Air Conditioner RLNL-B High Efficiency Series Nominal Sizes 6-12.5 Tons [21.1-44.0 kW] ASHRAE 90.1-2010 Compliant Models “Proper sizing and installation of equipment is critical to achieve optimal performance. Ask your Contractor for details or visit www.energystar.gov.” Rely on Ruud.™ FORM NO. S22-956 REV. 1 Table of Contents RLNL-B Series TABLE OF CONTENTS Unit Features & Benefits ..............................................................................3-7 Model Number Identification ............................................................................8 Options ....................................................................................................................9 Selection Procedure ......................................................................................10 General Data RLNL-B Series......................................................................................11-19 General Data Notes ......................................................................................20 Gross Systems Performance Data RLNL-B Series......................................................................................21-23 Airflow Performance RLNL-B- Series ....................................................................................24-28 Electrical Data RLNL-B- Series ....................................................................................29-32 Electric Heater Kits ..................................................................................33-38 Dimensional Data ....................................................................................39-42 Accessories ............................................................................................43-64 Mechanical Specifications ........................................................................65-66 Wiring Diagrams ......................................................................................67-70 Limited Warranty ..........................................................................................71 2 Rely on Ruud.™ Unit Features & Benefits RLNL-B Series STANDARD FEATURES INCLUDE: • R-410A HFC refrigerant. • Complete factory charged, wired and run tested. • Scroll compressors with internal line break overload and high-pressure protection. • Single stage compressor on B073 model. • Two stage compressor on B090 – B151 models. • Convertible airflow. • TXV refrigerant metering system on each circuit (except on B073). • High Pressure and Low Pressure/Loss of charge protection standard on all models. • Solid Core liquid line filter drier on each circuit. • Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintained high efficiencies. • Cooling operation up to 125 degree F ambient. • Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. • Hinged major access door with heavy-duty gasketing, 1/4 turn latches and door retainers. • Slide Out Indoor fan assembly for added service convenience. • Powder Paint Finish meets ASTMB117 steel coated on each side for maximum protection. G90 galvanized. • One piece top cover and one piece base pan with drawn supply and return opening for superior water management. • Forkable base rails for easy handling and lifting. • Single point electrical connections. • Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. • High performance belt drive motor with variable pitch pulleys and quick adjust belt system. • Permanently lubricated evaporator and condenser motors. • Condenser motors are internally protected, totally enclosed with shaft down design. • 2 inch filter standard with slide out design. • 24 volt control system with resettable circuit breakers. • Colored and labeled wiring. • Copper tube/Aluminum Fin coils (121/2 uses micro channel condenser). • Molded compressor plug. • Supplemental electric heat provides 100% efficient heating. Rely on Ruud.™ 3 The two-inch throwaway filters ( 10 ) are easily removed on a tracked system for easy replacement. 1995. and each unit bears the U. The sheet-metal cabinet ( 2 ) uses nothing less than 18-gauge material for structural components with an underlying coat of G90. Each unit also proudly displays the “Made in the USA” designation. per ASTM B117. removing areas that would allow for potential moisture accumulation. Each compartment has 1/4 turn fasteners and hinged access. the drain pan slides out for easy cleaning. which integrate fork slots and rigging holes to save set-up time on the job site. commercial-grade. and all edges are hidden. and sets the standard for coil protection in the industry. Ruud adheres to stringent IS0 9002 quality procedures. ease of installation and serviceability that goes into each unit. The Ruud hail guard (optional) ( 4 ) is its trademark. the design utilizes a one-piece top with a 1/8" drip lip ( 3 ). The clean design stands alone in the industry and is a testament to the quality.L. the large Ruud Commercial Series™ label ( 1 ) identifies the brand to the customer. hinged-access panel. Electrical wiring 9 diagrams are found on the control box cover. Furthermore. which allows contractors to move them to more readable locations. reliability. electrical data and other important unit information.Unit Features & Benefits RLNL-B Series 2 3 1 4 8 7 5 Ruud Package equipment is designed from the ground up with the latest features and benefits required to compete in today’s market. AHRI 340-370 and other Ruud-required reliability tests. On the outside of the panel is the unit nameplate. To the right of the control box the model and serial number can be found. To ensure the leak-proof integrity of these units. 6 6 4 Rely on Ruud. Electrical and filter compartment access is through a large. In this case. The production line quality test assurance label is also placed in this location ( 9 ). which contains the model and serial number. it is ready to go with a factory charge and quality checks.L. using electro deposition baked-on enamel tested to withstand a rigorous 1000-hour salt spray test. The base pan is stamped. Anything built to last must start with the right foundation. heating section. and outdoor section. All insulation is secured with both adhesive and mechanical fasteners. fullperimeter base rails ( 5 ). the foundation is 14-gauge. Every Ruud package unit uses the toughest finish in the industry. Contractors can rest assured that when a Ruud package unit arrives at the job. including the filter and electrical compartment. blower compartment. Having this information on the inside will assure model identification for 10 the life of the product. which can facilitate growth of harmful bacteria. The unit charging chart is located on the inside of the electrical and filter compartment door. and AHRI certification labels located on the unit nameplate ( 8 ). . which forms a 1-1/8" flange around the supply and return cover and has eliminated the worry of water entering the conditioned space ( 6 ). blower access and electric heat access). each unit was tested to U.™ During development. Each panel is permanently embossed with the compartment name (control/filter access. gasket-protected panels and screws. Access to all major compartments is from the front of the unit. Outwardly. The insulation has been placed on the underside of the basepan. The drainpan ( 7 ) is made of material that resists the growth of harmful bacteria and is sloped for the latest IAQ benefits. which are permanently identified by embossed wording that clearly identifies the compressor circuit. 11 15 12 To the right of the electrical and filter compartment are the externally mounted gauge ports. Once the pulley is removed. The “H” bushing allows for easy removal of the blower pulley from the shaft. Where the demands for the job require high static. The scroll housing ( 15 ) and blower scroll provide quiet and efficient airflow. creating burrs that make blower-pulley removal difficult. Ruud has high-static drives available that deliver nominal airflow up to 2" of static. By referring to the airflow performance tables listed in the installation instructions. To allow easy maintenance of 14 Rely on Ruud. the entire assembly easily slides out by removing the 3/8" screws from the blower retention bracket. which can score the shaft. The blower sheave is secured by an “H” bushing which firmly secures the pulley to the blower shaft for years of trouble-free operation. proper static pressure and CFM requirements can be dialed in. The high-voltage connection is terminated at the number 1 compressor contactor. each electrical component is clearly identified with a label that matches the component to the wire diagram for ease of trouble shooting. For added convenience in the field. an accurate diagnostic of system operation can be performed quickly and easily.™ 5 .Unit Features & Benefits RLNL-B Series 10 Inside the control box ( 11 ). The control transformer has a low voltage circuit breaker that trips if a low voltage electrical short occurs. All wiring is numbered on each end of the termination and colorcoded to match the wiring diagram. a factory-installed convenience outlet ( 12 ) is available. Low and High voltage can enter either from the side or through the base. The suggested mounting for the field-installed disconnect is on the exterior side of the electrical control box. the motor sheave can be adjusted to the desired number of turns. ranging from 0 to 6 turns open. the blower assembly. There is a blower contactor and compressor for each compressor. Low-voltage connections are made integrated cooling control. With the gauge ports mounted externally. The adjustable motor pulley ( 14 ) can easily be adjusted by loosening the bolts on either side of the motor mount. The blower compartment is to the right of the gauge ports and can be accessed by 1/4 turn fasteners. as opposed to the use of a set screw. Removing the bolts allows for easy removal of the blower pulley by pushing the blower assembly up to loosen the belt. high pressure connection and low pres13 sure connection ( 13 ). Power hook-up in the field is easy with single-point wiring to a terminal block ( 21 ) and a polarized plug for the low-voltage connection ( 22 ). and is UL certified ( 25 ). the electric furnace is completely wired for slide-in.) Wiring throughout the unit is neatly bundled and routed. The evaporator uses enhanced fin technology for maximum heat transfer. low-pressure switch ( 17 ).Unit Features & Benefits RLNL-B Series Also inside the blower compartment is the low-ambient control ( 16 ). and provides strain relief. this may occur if the outdoor fan motor fails. . The freeze stat protects the compressor if the evaporator coil gets too cold (below freezing) due to low airflow. The electric furnace comes with fuses for the unit ( 23 ) and for the electric furnace ( 24 ). (Note: 6 ton single stage has an orifice refrigerant control. the contractor is assured to get the correct amount of heating output to meet the designed heating load. high-pressure switch ( 18 ) and freeze stat refrigerant safety device ( 19 ) (optional). The electric heating elements are of a wound-wire construction ( 26 ) and isolated with ceramic bushings. Inside the blower compartment the interlaced evaporator can also be viewed. The 100% efficient electric furnace can be factory-installed or easily field-installed. The limit switch ( 27 ) protects the design from over-temperature conditions. Use of polarized plugs and sharder fittings allow for easy field installation. Each electric furnace has the capability to be converted from singlestage operation to two-stage operation by removing a jumper on the low-voltage terminal strip. The low-pressure switch shuts off the compressors if low pressure is detected due to loss of charge. Care is also taken to tuck raw edges of insulation behind sheet metal to improve indoor air quality. Each factory-installed option is brazed into the appropriate high or low side and wired appropriately. The high-pressure switch will shut off the compressors if pressures exceeds. plug-and-play installation in the field. Where wire harnesses go through the condenser bulkhead or blower deck. 16 610 PSIG are detected. a molded wire harness assembly ( 20 ) provides an air-tight and water-tight seal. The TXV metering device assures even distribution of refrigerant throughout the evaporator. The lowambient control allows for operation of the compressor down to 0 17 degrees ambient temperature by 18 cycling the outdoor fans on high pressure. Built with easeof-installation in mind.™ 20 26 27 21 22 25 24 23 The heating compartment contains the latest electric furnace technology on the market. 6 Rely on Ruud. With choices of up to six kilowatt offerings. Each unit is prewired for the economizer to allow quick plug-in installation. and shut 30 down cycle impose on the refrigerant tubing. which makes the assembly process quick and easy. The outdoor coil uses the latest enhanced fin design ( 33 ) for the most effective method of heat transfer. The economizer control has a minimum position setpoint. The 35 return air compart34 ment can also contain an economizer ( 35 ). and one for horizontal applications each with or without smoke detector. Each unit comes standard with filter dryer ( 31 ). The power exhaust 35 is housed in the barometric relief opening and is easily slipped in with a plug-in assembly. steady state operation. The economizer. which allow unobstructed airflow while protecting the unit from both Mother Nature and vandalism. The Ruud roofcurb ( 36 ) is made for toolless assembly at the jobsite by engaging a pin into the hinged corner brackets into the adjacent curb sides. which provides free cooling when outdoor conditions are suitable and also provides fresh air to meet local requirements.™ 7 . a mixair setpoint. first stage is approximately 50% of second stage (073 single stage). Each compressor and circuit is independent for built-in redundancy. Power Exhaust is easily field-installed. and each circuit is clearly marked throughout the system. quiet. Each unit is designed for both downflow or horizontal applications ( 34 ) for job configuration flexibility. and for reliable. The suction and discharge lines are designed with shock loops ( 30 ) to absorb the strain and stress that the starting 29 33 torque. The outdoor coil is protected by optional louvered panels.Unit Features & Benefits RLNL-B Series The compressor compartment houses the heartbeat of the unit. 36 Rely on Ruud. The wire harness to the economizer also has accommodations for a smoke detector. Each compressor has molded compressor plug eliminating potential for mis wiring. Barometric relief is standard on all economizers. The economizer is also available as a factoryinstalled option. Four models exits. and efficient operation. Each unit has two stages of efficient cooling operation. and a CO2 setpoint. an outdoor-air setpoint. one for downflow applications. The direct drive actuator combined with gear drive dampers has eliminated the need for linkage adjustment in the field. comes standard with single enthalpy controls. The polarized plug connection allows the motor to be changed quickly and eliminates the need to snake wires through the unit. The scroll compressor 31 ( 29 ) is known for its 32 long life. The controls can be upgraded to dual enthalpy easily in the field. The condenser fan motor ( 32 ) can easily be accessed and maintained through the compressor compartment. 38] 102 = 102.000 [21.Model Number Identification RLNL-B Series R L N L — B 090 C L 000 X X X Economizer Option (See Next Page) Factory Installed Options (See Next Page) Electric Heat 000 = No Resistance Heat 010 = 10 kW Resistance Heat 015 = 15 kW Resistance Heat 020 = 20 kW Resistance Heat 030 = 30 kW Resistance Heat 040 = 40 kW Resistance Heat 050 = 50 kW Resistance Heat Drive Package L = Belt Drive M= Belt Drive—High Static N = Belt Drive—RLNL-B090 Only Electrical Designation C = 208-230 V. 60 Hz Cooling Capacity (BTUH) [kW] 073 = 72.89] 120 = 120.000 [35. 3 PH. 3 PH.000 [26.10] 090 = 90.000 [29.™ .96] Future Technical Variations Design Series L = R410A Efficiency Designation N = High Efficiency EnergyStar Compliant Product Classification L = Packaged Air Conditioner– = Commercial Tradebrand R = Ruud Packaged Gas/Electric [ ] Designates Metric Conversions 8 Rely on Ruud. 60 Hz D = 460 V. 60 Hz Y = 575 V.17] 151 = 150.000 [43. 3 PH. . RLNL-B120CL000BYF ..........this unit has no factory installed options...1 TO 44...............Options RLNL-B Series 6 TO 12....... Choose a character from the FACTORY INSTALLED ECONOMIZER SELECTION TABLE...5 TON [21..0 kW] Option Code Hail Guard AD AG AP BY BJ CX JC x Non-Powered Convenience Outlet Low Ambient/ Freeze Stat x x x x x x x x x x x “x” indicates factory installed option....this unit is equipped with hail guards.......™ 9 ... RLNL-B120CL000BYA ...... Step 2.. ECONOMIZER SELECTION FOR LNL 6 TO 12..this unit is equipped with an Economizer with single enthalpy sensor and barometric relief with smoke detector............ Proceed to Step 2... After a basic rooftop model is selected........ Step 1..1 TO 44......... [ ] Designates Metric Conversions Rely on Ruud...... RLNL-B120CL000ADA ..... low ambient and unit freeze stat.. Examples: RLNL-B120CL000. RLNL-B120CL000AAG .. choose a two-character option code from the FACTORY INSTALLED OPTION SELECTION TABLE.0 kW] No Economizer A F G Single Enthalpy Economizer with Barometric Relief Single Enthalpy Economizer with Barometric Relief and Smoke Detector x x x “x” indicates factory installed option.......... The last option code character is utilized for factory-installed economizers. nothing follows the model number.. Instructions for Factory Installed Option(s) Selection Note: Three characters following the model number will be utilized to designate a factory-installed option or combination of options.this unit is equipped as above and includes an Economizer with single enthalpy sensor and with barometric relief. If no factory option(s) is required..this unit is equipped with hail guards.......5 TON [21.... DETERMINE COOLING AND HEATING REQUIREMENTS AND SPECIFIC OPERATING CONDITIONS FROM PLANS AND SPECS.145 BTUH [32. Net Total Capacity = 116. Example: Voltage— 230 V – 3 Phase – 60 Hz Total Cooling Capacity— 106.437 8. Select factors from airflow correction table at 3600 CFM [1699 L/s] and apply to data obtained in step 2 to obtain gross capacity: Total Capacity = 118.950 x 0.412 = 5.0 kW] Sensible Cooling Capacity— 82.12 kW] Sensible Capacity = 92.Selection Procedure RLNL-B Series To select an RLNL-B Cooling and Heating unit to meet a job requirement.40 in. follow this procedure.076 in.6°C] DB *Indoor Air Flow (vertical)— 3600 CFM [1699 L/s] *External Static Pressure— 0.6°C] DB evaporator entering air: 99. CALCULATE INDOOR BLOWER BTUH HEAT EFFECT FROM MOTOR WATTS. DETERMINE BLOWER SPEED AND WATTS TO MEET SYSTEM DESIGN.10 kPa] 2. motor) 10 Rely on Ruud. MINUS INDOOR BLOWER MOTOR HEAT.861 Watts These are Gross Capacities. CALCULATE UNIT INPUT AND JOB EER. EQUAL TO GROSS CAPACITY.12 kPa].377 BTUH [1.522 – 5.437 Watts EER = Net Total BTUH [kW] (step 6) 111.576 DRIVE = L (standard 2 H.9 kW] *Condenser Entering Air— 95°F [35. Watts (above) 10. with example.377 = 111. Fans) = 8.P. WG [.5) in.776 + 5.82 kW] Sensible Cooling Capacity = 99. 0 in.476 (0. WG [. SELECT UNIT HEATING CAPACITY. STEP 3.268 BTUH [27. *NOTE: These operating conditions are typical of a commercial application in a 95°F/79°F [35°C/26°C] design area with indoor design of 76°F [24°C] DB and 50% RH and 10% ventilation air. Total Power Input = 8.950 watts Use formula in note to determine sensible capacity at 78°F [25.950 BTUH [29.57 kW] 6.2°C] WB and 67°F [19. multiply kW x 3412 to convert to BTUH.00 kPa] for downflow air flow for a total selection static pressure of 0.98 = 116.0 kW] Add indoor blower heat effect (step 5) to Heater Kit Capacity to get total heating capacity: 163.02 kW] 3.900 x 0.4°C] to determine total and sensible capacity and power input for 65°F [18. 1. CALCULATE NET COOLING CAPACITIES.900 BTUH [34.655 BTUH [25.10 x 3.278 BTUH [24.” 0. WG [. with the unit roof mounted and centered on the zone it conditions by ducts.776 BTUH [48. STEP 4.655 – 5.09 kW] 7.268 x 0. Interpolate between 63°F [17.000 BTUH [31.02 kPa] for wet coil. CHOOSE MODEL RLNL-B120CL050.27 kW] Power Input (Compressor and Cond.3°C] WB 78°F [25. WG [.1 kW] unit.153 BTUH [49.99 = 8.0°C] DB *Evaporator Mixed Air Entering— 65°F [18. SELECT UNIT TO MEET COOLING REQUIREMENTS.576 (step 4) = 10. WG [.67 kW] Power Input = 8.861 (step 3) + 1.™ 5. enter cooling performance table at 95°F [35. and determine: RPM = 769 WATTS = 1.10 kPa] includes the system duct and grilles.0°C] DB condenser inlet air. Use 50 kW Heater Kit Heater Kit Model: RXU-CC50C Heater Kit Capacity: 163.65 Power Input. [ ] Designates Metric Conversions . Since total cooling is within the range of a nominal 10 ton [35.000 BTUH [24. Total ESP (external static pressure) per the spec of 0.5 kW] 9.54 kW] Net Sensible Capacity = 87.377 = 82. using data supplied in this specification sheet.600 x (1 – 0. 4. not corrected for blower motor heat or power.145 = = 10.522 BTUH [34. 1.3°C] WB evaporator inlet air at 3750 CFM [1770 L/s] indoor air flow (table basis): Total Cooling Capacity = 118.40 in. CORRECT CAPACITIES OF STEP 2 FOR ACTUAL AIR FLOW. Enter Indoor Blower performance table at 3600 CFM [1699 L/s]. Add from the table “Component Air Resistance.95 = 87.950 + (1.0 kW] Heating Capacity— 150.000 BTUH [43.576 x 3. From Heater Kit Table select kW to meet heating capacity requirement.03) x (78 – 80)) Sensible Cooling Capacity = 92.377 = 169. ) Size Recommended in. [kg] 901 [409] 901 [409] 901 [409] 901 [409] Ship Weight lbs.6] IEER3 Net System Power [kW] Compressor No.Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] B073CL B073CM B073DL B073DM 75. Used/Diameter in.42 6. [mm] Drive Type/No.5] 0./Size in.97] 11.5 [1.375 [9. [mm] Drive Type/No.47] 52.63] 11.6] Propeller 2/24 [609.8 19. [sq.1] 72.000 [21.5 [1.6] Propeller 2/24 [609. m] 13.1-44.8 19.5] 0.4] Propeller 2/24 [609.800 [15. [g] Weights See Page 20 for Notes. Motors Motor Frame Size Filter—Type Furnished (NO.000 [21.0 kW] ASHRAE 90.63] 11.25] 13.General Data RLNL-B Series NOM.42 1/Scroll 1/Scroll 1/Scroll 1/Scroll 88 88 88 88 Louvered Rifled Louvered Rifled Louvered Rifled Louvered Rifled Tube Size in. SIZES 6-12.200 [5.42 6.000 [21.™ 11 .4] 1/1 [25.5] 0.97] 75.63] 11.25] 13.000 [21. [mm x mm x mm] (6)2x18x18 [51x457x457] (6)2x18x18 [51x457x457] (6)2x18x18 [51x457x457] (6)2x18x18 [51x457x457] 125 [3544] 125 [3544] 125 [3544] 125 [3544] Net Weight lbs. Used/Diameter in.375 [9.97] CONTINUED 75.1] 72.25] 13.800 [15.47] 52. [ ] Designates Metric Conversions Rely on Ruud.8 19.63] 11.5 [1.5 [1.200 [5. [sq.6] Propeller 2/24 [609.8 6.47] 52.97] 75.5] 0.5] 0./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Tube Type Outdoor Fan—Type No.25] 13. Motors/HP 2 at 1/3 HP 2 at 1/3 HP 2 at 1/3 HP 2 at 1/3 HP 1075 1075 1075 1075 FC Centrifugal 1/11x12 [279x305] FC Centrifugal 1/11x12 [279x305] FC Centrifugal 1/11x12 [279x305] FC Centrifugal 1/11x12 [279x305] Belt/Variable Belt/Variable Belt/Variable Belt/Variable 1 1 1 1 Motor HP 1 1/2 1 1/2 1 1/2 1 1/2 Motor RPM 1725 1725 1725 1725 56 56 56 56 Disposable Yes Disposable Yes Disposable Yes Disposable Yes Motor RPM Indoor Fan—Type No. [mm] OD 0.375 [9.5] 0.1] Net Sensible Capacity Btu [kW] 52.5] Face Area sq.5 [1.25] Rows / FPI [FPcm] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] Indoor Coil—Fin Type Tube Type Louvered Rifled Louvered Rifled Louvered Rifled Louvered Rifled Tube Size in.375 [9.1-2010 COMPLIANT MODELS Model RLNL. m] 13.800 [15. [mm] 0.5 TONS [21. [kg] 938 [425] 938 [425] 938 [425] 938 [425] Refrigerant Charge Oz.25] 13. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 8000 [3775] 8000 [3775] 8000 [3775] 8000 [3775] No.2/NA 11.2/NA 11.2/NA 11.25] 13.1] 72. Speeds No.000 [21.375 [9.375 [9. ft.375 [9.000 [21.200 [5.5] Face Area sq.000 [21.5 [1.5 [1.2/NA 2400/2325 [1133/1097] 2400/2325 [1133/1097] 2400/2325 [1133/1097] 2400/2325 [1133/1097] AHRI Net Cooling Capacity Btu [kW] 72.375 [9.000 [21.5 [1.200 [5.42 6.800 [15.4] 1/1 [25. [mm] 1/1 [25.25] Rows / FPI [FPcm] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No.4] 1/1 [25.47] Net Latent Capacity Btu [kW] 19. ft. 000 [21.6] Propeller 2/24 [609.2/NA 11.42 7. Used/Diameter in.4] 1/1 [25.000 [27.8 11.0 kW] ASHRAE 90.000 [26.47] 52.2/NA 2400/2325 [1133/1097] 2400/2325 [1133/1097] 3000/2775 [1416/1310] 3000/2775 [1416/1310] AHRI Net Cooling Capacity Btu [kW] 72.000 [21.25] 75.900 [7.1-44.25] 27 [2. m] 13.800 [15.6] Compressor No. SIZES 6-12.1] 90. [mm] 0.375 [9.5 [1.51] Rows / FPI [FPcm] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] Indoor Coil—Fin Type Tube Type Louvered Rifled Louvered Rifled Louvered Rifled Louvered Rifled Tube Size in.37] Net Sensible Capacity Btu [kW] 52.47] 63. ft. Used/Diameter in.375 [9.6] Propeller 2/24 [609. Motors/HP 2 at 1/3 HP 2 at 1/3 HP 2 at 1/3 HP 2 at 1/3 HP 1075 1075 1075 1075 FC Centrifugal 1/11x12 [279x305] FC Centrifugal 1/11x12 [279x305] FC Centrifugal 1/15x15 [381x381] FC Centrifugal 1/15x15 [381x381] Belt/Variable Belt/Variable Belt/Variable Belt/Variable 1 1 1 1 Motor HP 1 1/2 1 1/2 2 2 Motor RPM 1725 1725 1725 1725 Motor RPM Indoor Fan—Type No.5] 0.000 [21.5] 0. [mm] OD 0.7 [3048/3138] Net Weight lbs. Motors Motor Frame Size 56 56 56 56 Disposable Yes Disposable Yes Disposable Yes Disposable Yes (6)2x18x18 [51x457x457] (6)2x18x18 [51x457x457] (6)2x18x18 [51x457x457] (6)2x18x18 [51x457x457] 125 [3544] 125 [3544] 107.General Data RLNL-B Series NOM.25] CONTINUED 93.375 [9.37] 90.51] 27 [2.97] 11.800 [15.) Size Recommended in.88] 26.6] Propeller 2/24 [609.900 [7. [ ] Designates Metric Conversions 12 Rely on Ruud. [sq.000 [26.99 1/Scroll 1/Scroll 2/Scroll 2/Scroll 88 88 88 88 Louvered Rifled Louvered Rifled Louvered Rifled Louvered Rifled Tube Size in.97] 75.88] IEER3 11.9 Net System Power [kW] 6.™ .25] 13. m] 13.Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] B073YL B073YM B090CL B090CM 93.4] 1/1 [25. [sq.5 [1. [mm] 1/1 [25.5 [1.200 [5.25] 13.100 [18.1-2010 COMPLIANT MODELS Model RLNL. [mm x mm x mm] Refrigerant Charge Oz.1] 72.5 TONS [21.5 [1.375 [9.4] Propeller 2/24 [609. [g] Weights See Page 20 for Notes.99 7.000 [21.2/NA 11.63] 26.5] 0.5] 0.2/NA 11. [mm] Drive Type/No.375 [9.5] 0.8 11./Size in.25] 13.5] Face Area sq. [mm] Drive Type/No.375 [9.375 [9.100 [18.5/110.49] Net Latent Capacity Btu [kW] 19.5] Face Area sq.7 [3048/3138] 107.9 11.200 [5.49] 63.000 [27.5 [1.25] 13.42 6.4] 1/1 [25.5/110. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 8000 [3775] 8000 [3775] 8000 [3775] 8000 [3775] No. [kg] 901 [409] 901 [409] 1017 [461] 1017 [461] Ship Weight lbs.25] Rows / FPI [FPcm] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Tube Type Outdoor Fan—Type No. ft. [kg] 938 [425] 938 [425] 1054 [478] 1054 [478] Filter—Type Furnished (NO. Speeds No.5] 0.375 [9.63] 19.5 [1. 6] 2/24 [609.2/NA CONTINUED 93.0 kW] ASHRAE 90.375 [9.5/110. [mm] Refrigerant Charge Oz.4] Propeller 2 / 18 [7] TX Valves 1/1 [25.) Size Recommended in.5] Louvered Rifled 0. m] Face Area sq.4] Propeller 2 / 18 [7] TX Valves 1/1 [25.5/110.375 [9. Used/Diameter in.000 [26.5 [1.9 11.100 [18.25] 11.375 [9.49] Net Latent Capacity Btu [kW] 26.7 [0.375 [9.375 [9.51] Rows / FPI [FPcm] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] Indoor Coil—Fin Type Tube Type Tube Size in.100 [18.25] 2 / 18 [7] TX Valves 1/1 [25.25] 13.88] 26.88] 26.1-44. Speeds CFM [L/s] No.99 7.5/110.7 [3048/3138] Yes (6)2x18x18 [51x457x457] 107.7 [3048/3138] Yes (6)2x18x18 [51x457x457] 107. [mm] Drive Type/No.49] 63.25] 11. [sq. [kg] 1062 [482] 1054 [478] 1054 [478] 1062 [482] Indoor Fan—Type No.4] Propeller 2 / 18 [7] TX Valves 1/1 [25.37] 3000/2775 [1416/1310] 90.6] Direct/1 Direct/1 Direct/1 Direct/1 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Compressor No.5] 2.000 [26.5] Louvered Rifled 0. Motors 1 1 1 1 Motor HP 3 2 2 3 1725 1725 1725 1725 56 Disposable 56 Disposable 56 Disposable 56 Disposable Yes (6)2x18x18 [51x457x457] 107.99 7.99 7.37] Net Sensible Capacity Btu [kW] 63.000 [27.General Data RLNL-B Series NOM.5/110.25] Rifled 0.900 [7.5 [1.99 2/Scroll 88 2/Scroll 88 2/Scroll 88 2/Scroll 88 Louvered Louvered Louvered Louvered Rifled 0.5] 27 [2.51] Rifled 0. SIZES 6-12.5 [1.88] IEER3 11.25] 11.6] 2/24 [609. 2) [g] Weights See Page 20 for Notes.37] 3000/2775 [1416/1310] 90.25] 11. Motors/HP Motor RPM 1075 1075 1075 1075 FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable No.000 [26.49] 63. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No. ft.000 [27.2/NA 3000/2775 [1416/1310] 90.25] 13.7 [0.100 [18.6] 2/24 [609./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Tube Type Tube Size in.9 11.9 Net System Power kW 7.375 [9. [mm] Louvered Rifled 0.100 [18.5] 2.37] 3000/2775 [1416/1310] 90. ft.9 11.5 [1. [ ] Designates Metric Conversions Rely on Ruud./Size in.49] 63.™ 13 .1-2010 COMPLIANT MODELS Model RLNL.Series B090CN B090DL B090DM B090DN 93. Used/Diameter in.5] Louvered Rifled 0.900 [7. [kg] 1025 [465] 1017 [461] 1017 [461] 1025 [465] Ship Weight lbs.375 [9.88] 26.2/NA 93.900 [7. [mm] Drive Type/No.2/NA 93. [mm] OD Face Area sq.25] Rifled 0. [sq.5] 27 [2.000 [27.5 TONS [21.000 [26.5] 13.375 [9. [mm] Outdoor Fan—Type No. Speeds Motor RPM Motor Frame Size Filter—Type Furnished (No. (Sys.4] Propeller 2/24 [609. 1/Sys.25] 13.000 [27.7 [3048/3138] Net Weight lbs.7 [3048/3138] Yes (6)2x18x18 [51x457x457] 107.900 [7. 37] 3200/3200 [1510/1510] 97./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Tube Type Tube Size in.375 [9.9 12 Net System Power kW 7.375 [9.7 [3048/3138] Yes (6)2x18x18 [51x457x457] 107. [mm] Drive Type/No.4/166. [mm] Refrigerant Charge Oz.49] 63.51] Rifled 0.99 7.25] 11.5 TONS [21.000 [21.99 7. Used/Diameter in.100 [18.5] Louvered Rifled 0.1-44.99 8. [kg] 1054 [478] 1054 [478] 1062 [482] 1096 [497] Indoor Fan—Type No.5] 27 [2.42] Net Sensible Capacity Btu [kW] 63.25] 11.9 11.000 [27. Speeds CFM [L/s] No.4] Propeller 2 / 18 [7] TX Valves 1/1 [25.6 [4377/4723] Net Weight lbs.375 [9.6] 2/24 [609.5] Louvered Rifled 0. m] Face Area sq. [mm] Outdoor Fan—Type No./Size in.100 [18. 2) [g] Weights See Page 20 for Notes.51] Rows / FPI [FPcm] 1 / 22 [9] 1 / 22 [9] 1 / 22 [9] 2 / 18 [7] Indoor Coil—Fin Type Tube Type Tube Size in.5/110. Speeds Motor RPM Motor Frame Size Filter—Type Furnished (No. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No.100 [18.9 11.General Data RLNL-B Series NOM. [sq.7 [3048/3138] Yes (6)2x18x18 [51x457x457] 107. SIZES 6-12.375 [9.000 [26.5] 27 [2.6] 2/24 [609.74] IEER3 11.25] 2 / 18 [7] TX Valves 1/1 [25.68] Net Latent Capacity Btu [kW] 26.000 [27.6] 2/24 [609.2/NA 3000/2775 [1416/1310] 90.2/NA 93.6] Direct/1 Direct/1 Direct/1 Direct/1 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Compressor No. Motors/HP Motor RPM 1075 1075 1075 1075 FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable No.5/110.5/110.1-2010 COMPLIANT MODELS Model RLNL.5] Louvered Rifled 0. Used/Diameter in. Motors 1 1 1 1 Motor HP 2 2 3 2 1725 1725 1725 1725 56 Disposable 56 Disposable 56 Disposable 56 Disposable Yes (6)2x18x18 [51x457x457] 107.5] 13.49] 74. [mm] Louvered Rifled 0. [sq. [mm] OD Face Area sq.5 [1.900 [7.5] 27 [2.25] 13.375 [9.000 [27.000 [29.25] 11. ft.000 [26.88] 26.) Size Recommended in.49] 63.7 [3048/3138] Yes (6)2x18x18 [51x457x457] 154.4] Propeller 2/24 [609.5 [1.2/NA 93.5 [1.88] 26. (Sys. [ ] Designates Metric Conversions 14 Rely on Ruud.Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 B090YL B090YM B090YN B102CL 93.™ .51] Rifled 0.4] Propeller 2 / 18 [7] TX Valves 1/1 [25.375 [9. 1/Sys. ft. [mm] Drive Type/No.25] 13.25] 13.375 [9.000 [28.000 [26.4] Propeller 2 / 18 [7] TX Valves 1/1 [25.5 [1.5] 27 [2.37] 3000/2775 [1416/1310] 90.51] Rifled 0.59 2/Scroll 88 2/Scroll 88 2/Scroll 88 2/Scroll 88 Louvered Louvered Louvered Louvered Rifled 0. [kg] 1017 [461] 1017 [461] 1025 [465] 1059 [480] Ship Weight lbs.000 [6.2/NA CONTINUED 101.900 [7.900 [7.37] 3000/2775 [1416/1310] 90.375 [9.88] 23.0 kW] ASHRAE 90.59] 11. 5 [1.4] Propeller 2/24 [609.6 [4377/4723] Yes (6)2x18x18 [51x457x457] 154.1-2010 COMPLIANT MODELS Model RLNL.59] 11.2/NA 101.000 [28.6 [4377/4723] Yes (6)2x18x18 [51x457x457] 154.0 kW] ASHRAE 90.6 [4377/4723] Yes (6)2x18x18 [51x457x457] 154.59] 11. Speeds Motor RPM Motor Frame Size Filter—Type Furnished (No.4/166.000 [21.000 [29. 1/Sys. [sq. [mm] OD Face Area sq. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No. ft. [sq.59] 11.5] Louvered Rifled 0. [mm] Drive Type/No.000 [6.375 [9.59] 11.51] Rifled 0.2/NA CONTINUED 101.59 8.5] 13.™ 15 .4] Propeller 2 / 18 [7] TX Valves 1/1 [25.68] 74.59 2/Scroll 88 2/Scroll 88 2/Scroll 88 2/Scroll 88 Louvered Louvered Louvered Louvered Rifled 0.4] Propeller 2 / 18 [7] TX Valves 1/1 [25.000 [21.74] 23.74] 23.General Data RLNL-B Series NOM.000 [29.42] 3200/3200 [1510/1510] 97.375 [9. [mm] Drive Type/No.6] 2/24 [609. [mm] Refrigerant Charge Oz.4/166.5] 27 [2. Used/Diameter in./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Tube Type Tube Size in. Motors 1 1 1 1 Motor HP 3 2 3 2 1725 1725 1725 1725 56 Disposable 56 Disposable 56 Disposable 56 Disposable Yes (6)2x18x18 [51x457x457] 154.51] Rifled 0.68] 74.6] 2/24 [609.Series B102CM B102DL B102DM B102YL 101. (Sys.375 [9.74] 12 12 12 12 8.68] 74.375 [9. [mm] Louvered Rifled 0. Speeds CFM [L/s] No. Used/Diameter in.000 [28.6 [4377/4723] Net Weight lbs. [kg] 1104 [501] 1096 [497] 1104 [501] 1096 [497] Indoor Fan—Type No.6] Direct/1 Direct/1 Direct/1 Direct/1 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] IEER3 Net System Power kW Compressor No. [kg] 1067 [484] 1059 [480] 1067 [484] 1059 [480] Ship Weight lbs.42] 3200/3200 [1510/1510] 97. [mm] Outdoor Fan—Type No.000 [28.375 [9.375 [9.000 [21.375 [9.5 TONS [21.74] 23.000 [29.000 [28.000 [21. Motors/HP Motor RPM 1075 1075 1075 1075 FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable No.5] Louvered Rifled 0.000 [6./Size in.59 8. SIZES 6-12.51] Rows / FPI [FPcm] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] Indoor Coil—Fin Type Tube Type Tube Size in.1-44.51] Rifled 0.4/166.4] Propeller 2 / 18 [7] TX Valves 1/1 [25.42] 3200/3200 [1510/1510] 97.000 [29. [ ] Designates Metric Conversions Rely on Ruud.5 [1.42] Net Sensible Capacity Btu [kW] 74.2/NA 3200/3200 [1510/1510] 97.375 [9.25] 2 / 18 [7] TX Valves 1/1 [25.5 [1.5] Louvered Rifled 0.000 [6. 2) [g] Weights See Page 20 for Notes.6] 2/24 [609.4/166. m] Face Area sq.25] 13.5] 27 [2.59 8.25] 13.) Size Recommended in.2/NA 101.68] Net Latent Capacity Btu [kW] 23. ft.000 [6.25] 13.5] 27 [2.5] 27 [2.5 [1. 5] Louvered Rifled 0. [kg] 1096 [497] 1149 [521] 1157 [525] 1149 [521] Indoor Fan—Type No./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Tube Type Tube Size in. Speeds CFM [L/s] No.57] Net Sensible Capacity Btu [kW] 74. [mm] Outdoor Fan—Type No.49 10.800 [26.8/180.) Size Recommended in.000 [36. Motors/HP Motor RPM 1075 1075 1075 1075 FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable No.5] 27 [2.4] Propeller 3 / 18 [7] TX Valves 1/1 [25.56] 29.4/166.5] 27 [2.42] 4000/3750 [1888/1770] 118.000 [34. [mm] Refrigerant Charge Oz.04] 11.51] Rifled 0.375 [9.02] Net Latent Capacity Btu [kW] 23. [sq.6] 2/24 [609.375 [9. Speeds Motor RPM Motor Frame Size Filter—Type Furnished (No.000 [36. (Sys.49 10.2/NA 123.5 [1.5] Louvered Rifled 0. [mm] Drive Type/No.™ . ft.5 [1.02] 88.800 [26.5] 27 [2. [sq.59] 11.4] Propeller 3 / 18 [7] TX Valves 1/1 [25.74] 29. 2) [g] Weights See Page 20 for Notes.200 [8.9 11.1-44.9 8.51] Rifled 0. [mm] Drive Type/No.000 [34.59 10.6] 2/24 [609.04] 11. Motors 1 1 1 1 Motor HP 3 2 3 2 1725 1725 1725 1725 56 Disposable 56 Disposable 56 Disposable 56 Disposable Yes (6)2x18x18 [51x457x457] 154. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No.000 [36.8 [4899/5126] Yes (6)2x18x18 [51x457x457] 172.375 [9.51] Rows / FPI [FPcm] 2 / 18 [7] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Indoor Coil—Fin Type Tube Type Tube Size in. Used/Diameter in.49 2/Scroll 88 2/Scroll 88 2/Scroll 88 2/Scroll 88 Louvered Louvered Louvered Louvered Rifled 0.2/NA 123. SIZES 6-12.02] 88. 1/Sys.5] Louvered Rifled 0.5 TONS [21.000 [21.5 [1.0 kW] ASHRAE 90.375 [9./Size in.25] 13.1-2010 COMPLIANT MODELS Model RLNL.375 [9.2/NA CONTINUED 123.25] 13.200 [8. m] Face Area sq.000 [28. ft.2/NA 3200/3200 [1510/1510] 97.8/180.000 [29.9 11.6] Direct/1 Direct/1 Direct/1 Direct/1 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] IEER3 Net System Power kW Compressor No.25] 2 / 18 [7] TX Valves 1/1 [25.56] 29.8 [4899/5126] Net Weight lbs.4] Propeller 3 / 18 [7] TX Valves 1/1 [25.68] 88.Series B102YM B120CL B120CM B120DL 101.57] 4000/3750 [1888/1770] 118.4] Propeller 2/24 [609. [mm] Louvered Rifled 0. [ ] Designates Metric Conversions 16 Rely on Ruud.5] 27 [2.51] Rifled 0.375 [9.000 [34.6 [4377/4723] Yes (6)2x18x18 [51x457x457] 172.04] 11.General Data RLNL-B Series NOM.8/180. Used/Diameter in.25] 13.5 [1.000 [6.375 [9. [mm] OD Face Area sq.8 [4899/5126] Yes (6)2x18x18 [51x457x457] 172.800 [26.56] 12 11.375 [9.6] 2/24 [609. [kg] 1059 [480] 1112 [504] 1120 [508] 1112 [504] Ship Weight lbs.5] 13.200 [8.57] 4000/3750 [1888/1770] 118. 8/180.57] 4000/3750 [1888/1770] 118. Speeds Motor RPM Motor Frame Size Filter—Type Furnished (No. ft.5] Louvered Rifled 0.375 [9.8 [4899/5126] Yes (6)2x18x18 [51x457x457] 172.02] 106. [mm] Drive Type/No.2/NA 123. [mm] Outdoor Fan—Type No.1-44.2/152 [4173/4309] Net Weight lbs.Series B120DM B120YL B120YM B151CL 123. Used/Diameter in. [sq. Used/Diameter in.95] Net Sensible Capacity Btu [kW] 88.200 [8.5] 27 [2.51] Rifled 0. [mm] Refrigerant Charge Oz. [ ] Designates Metric Conversions Rely on Ruud. m] Face Area sq.49 10.5 [1.375 [9.375 [9.6] Direct/1 Direct/1 Direct/1 Direct/1 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/3 HP 8000 [3775] 2 at 1/2 HP Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Compressor No.5] Louvered Rifled 0. Motors 1 1 1 1 Motor HP 3 2 3 3 1725 1725 1725 1725 56 Disposable 56 Disposable 56 Disposable 56 Disposable Yes (6)2x18x18 [51x457x457] 172.375 [9.4] Propeller 4 / 15 [6] TX Valves 1/1 [25.23] Net Latent Capacity Btu [kW] 29.0 kW] ASHRAE 90.49 13.5 TONS [21.72] IEER3 11.49 10.000 [36.6] 2/24 [609.04] 11.71] 11.5 [1.000 [36.1-2010 COMPLIANT MODELS Model RLNL.5 [1.57] 4000/3750 [1888/1770] 118.5] 13.25] 13.2/NA CONTINUED 156.000 [45.4] Propeller 2/24 [609.4] Propeller 3 / 18 [7] TX Valves 1/1 [25.) Size Recommended in.1/NA 4000/3750 [1888/1770] 118.800 [26.000 [34.375 [9.9 11.400 [12.25] 13./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Tube Type Tube Size in.54 2/Scroll 88 2/Scroll 88 2/Scroll 88 2/Scroll 88 Louvered Louvered Louvered Louvered Rifled 0.2/NA 123. [mm] Louvered Rifled 0.56] 29.6] 2/24 [609.000 [43.4] 27 [2.8/180.200 [8.51] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 23 [9] Indoor Coil—Fin Type Tube Type Tube Size in.600 [31.8 Net System Power kW 10.56] 43.5] 27 [2.™ 17 .200 [8.375 [9. SIZES 6-12.5] 27 [2.56] 29. 1/Sys.51] Rifled 0. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No. [sq.51] MicroChannel 1 [25.04] 11.4] Propeller 3 / 18 [7] TX Valves 1/1 [25. Motors/HP Motor RPM 1075 1075 1075 1075 FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable No.8/180. [mm] OD Face Area sq.375 [9.5 [1.800 [26.02] 88.25] 3 / 18 [7] TX Valves 1/1 [25./Size in.000 [34. [kg] 1120 [508] 1112 [504] 1120 [508] 1230 [558] Ship Weight lbs.5] Louvered Rifled 0. ft.General Data RLNL-B Series NOM.000 [36. 2) [g] Weights See Page 20 for Notes. (Sys.57] 5000/4225 [2360/1994] 150.02] 88.9 11. [kg] 1157 [525] 1149 [521] 1157 [525] 1267 [575] Indoor Fan—Type No.000 [34.800 [26.25] 13.9 10. [mm] Drive Type/No.6] 2/24 [609.8 [4899/5126] Yes (6)2x18x18 [51x457x457] 147.04] 11.8 [4899/5126] Yes (6)2x18x18 [51x457x457] 172. Speeds CFM [L/s] No. 4] 27 [2.25] 13. Used/Diameter in. Speeds CFM [L/s] No.5 [1.95] 5000/4225 [2360/1994] 150.5 [1.000 [43.600 [31.5] Louvered Rifled 0.2/152 [4173/4309] Net Weight lbs. [ ] Designates Metric Conversions 18 Rely on Ruud. [sq.23] 106. 2) [g] Weights See Page 20 for Notes.600 [31. [mm] Drive Type/No. ft.4] Propeller 4 / 15 [6] TX Valves 1/1 [25./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered MicroChannel 1 [25./Size in.71] 11. m] Face Area sq.4] Propeller 4 / 15 [6] TX Valves 1/1 [25.4] 27 [2.400 [12.000 [45.8 Net System Power kW 13.95] Net Sensible Capacity Btu [kW] 106.72] IEER3 10. Motors 1 1 1 1 Motor HP 5 3 5 3 1725 1725 1725 1725 184 Disposable 56 Disposable 184 Disposable 56 Disposable Yes (6)2x18x18 [51x457x457] 147.000 [45.400 [12.1/NA CONTINUED 156. Used/Diameter in.8 10.™ .2/152 [4173/4309] Yes (6)2x18x18 [51x457x457] 147. [kg] 1275 [578] 1267 [575] 1275 [578] 1267 [575] Indoor Fan—Type No.600 [31.000 [45.6] 2/24 [609.5] Louvered Rifled 0.54 13.51] MicroChannel 1 [25.51] MicroChannel 1 [25.4] Propeller 4 / 15 [6] TX Valves 1/1 [25.54 13. [mm] Outdoor Fan—Type No.0 kW] ASHRAE 90.6] 2/24 [609.1/NA 156.400 [12.72] 43.51] Rows / FPI [FPcm] 2 / 23 [9] 2 / 23 [9] 2 / 23 [9] 2 / 23 [9] Indoor Coil—Fin Type Tube Type Tube Size in.5] 13.000 [43.2/152 [4173/4309] Yes (6)2x18x18 [51x457x457] 147.000 [43.5 [1. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No.1/NA 5000/4225 [2360/1994] 150. (Sys.General Data RLNL-B Series NOM.23] 106. [mm] Louvered Rifled 0.71] 11.375 [9.25] 13.8 10. [mm] Refrigerant Charge Oz. Motors/HP Motor RPM 1075 1075 1075 1075 FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable FC Centrifugal 1/15x15 [381x381] Belt/Variable No. ft.375 [9.4] 27 [2.Series B151CM B151DL B151DM B151YL 156.1-44. [mm] OD Face Area sq.95] 5000/4225 [2360/1994] 150. Speeds Motor RPM Motor Frame Size Filter—Type Furnished (No.600 [31.) Size Recommended in.000 [45.4] 27 [2.1/NA 156.5 [1.4] Propeller 2/24 [609. SIZES 6-12.1-2010 COMPLIANT MODELS Model RLNL.23] Net Latent Capacity Btu [kW] 43.5 TONS [21. [kg] 1238 [562] 1230 [558] 1238 [562] 1230 [558] Ship Weight lbs.23] 106.2/152 [4173/4309] Yes (6)2x18x18 [51x457x457] 147.72] 43. [mm] Drive Type/No. [sq.8 10.000 [43.6] Direct/1 Direct/1 Direct/1 Direct/1 8000 [3775] 2 at 1/2 HP 8000 [3775] 2 at 1/2 HP 8000 [3775] 2 at 1/2 HP 8000 [3775] 2 at 1/2 HP Tube Type Tube Size in.6] 2/24 [609.54 13.95] 5000/4225 [2360/1994] 150.71] 11.375 [9.5] Louvered Rifled 0.72] 43.71] 11.51] MicroChannel 1 [25.25] 4 / 15 [6] TX Valves 1/1 [25. 1/Sys.400 [12.375 [9.25] 13.54 2/Scroll 88 2/Scroll 88 2/Scroll 88 2/Scroll 88 Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Compressor No. 600 [31. [sq.5 TONS [21. 1/Sys. Motors/HP Motor RPM Indoor Fan—Type No. [mm] Drive Type/No.23] Net Latent Capacity Btu [kW] 43.™ 19 .4] 27 [2.400 [12.0 kW] ASHRAE 90./Type Outdoor Sound Rating (dB)4 Outdoor Coil—Fin Type Tube Type Tube Size in.8 Net System Power kW 13.375 [9.2/152 [4173/4309] Weights Net Weight lbs.95] Net Sensible Capacity Btu [kW] 106. [mm] Drive Type/No. [mm] Outdoor Fan—Type No. [mm] Refrigerant Charge Oz.5] Face Area sq. [ ] Designates Metric Conversions Rely on Ruud. [kg] 1275 [578] See Page 20 for Notes. Speeds No. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No. ft.) Size Recommended in.71] 11. Motors Motor HP Motor RPM Motor Frame Size Filter—Type Furnished (No.5 [1. [sq. m] 2/Scroll 88 Louvered MicroChannel 1 [25.000 [45. Used/Diameter in./Size in.General Data RLNL-B Series NOM. 2) [g] 13.54 Compressor No.1/NA 5000/4225 [2360/1994] 150.Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] B151YM 156. [mm] Louvered Rifled 0.4] Propeller 2/24 [609. [mm] OD Face Area sq. [kg] 1238 [562] Ship Weight lbs.6] Direct/1 8000 [3775] 2 at 1/2 HP 1075 FC Centrifugal 1/15x15 [381x381] Belt/Variable 1 5 1725 184 Disposable Yes (6)2x18x18 [51x457x457] 147. SIZES 6-12.72] IEER3 10.51] Rows / FPI [FPcm] 2 / 23 [9] Indoor Coil—Fin Type Tube Type Tube Size in. Speeds CFM [L/s] No. Used/Diameter in.000 [43.25] 4 / 15 [6] TX Valves 1/1 [25.1-44.1-2010 COMPLIANT MODELS Model RLNL. (Sys. ft. 80° F entering dry bulb. and 67° F entering wet bulb at AHRI rated cfm. IEER is rated in accordance with AHRI Standard 340/360. 4. 20 Rely on Ruud. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures. AHRI capacity is net and includes the effect of fan motor heat. 67° F entering wet bulb. Units are suitable for operation to ⫾20% of nominal cfm. 3. Units are rated at 80° F ambient.™ . 80° F entering dry bulb. Cooling Performance is rated at 95° F ambient. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program. which is based on AHRI Standard 340/360. Gross capacity does not include the effect of fan motor heat. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.General Data Notes RLNL-B Series NOTES: 1. 2. 1 [18.4] 4.7°C] 2775 [1310] .1 [13.2 69.7 [21.9 [27.0 101.7 96.9 [14.7 [27.5] 69.5 87.7] 92.6] 5.3] 40.3 95.4] 4.01 1860 [878] .1] 72.2] 56.0 76.2 93.2 103.8 [21.7] 49.9] 81.2 [15.2 59.0 72.7 [19.9] Power O Total BTUH [kW] U 80 T Sens BTUH [kW] [26.6] 65.6 [19.3 [27.3 [15.3 [16.6] 8.8] 4.6 [16.8 Power 105.4 [23.1] Power 91.5 [29.5 [25.5] 55.5 [10.5 [18.3 61.7 74.6 102.8] 6.9] 8.7 [22.3 [29.0 [16.9] 7.7 [24.3] 5.4] 6.4 83.4°C] 2775 [1310] .9 [25.5 [30.9] 51.4] 6.6] 77.9] 9.2] 7.8] 41.2] 6.8] 71.2 [28.6] 38.5] 7.9 [17.0] 8.3 [20.4] 7.7 [29.8 [17.1] 47.5 77.4 [13.0] 6.3] 70.4] 48.9 [23.5 [23.1] 7.7] 68.6 [16.5] 5.3 77.8] 7.0 [14.3 66.7] 42.1 78.0 94.9 88.9 92.2] 76.7 [25.0] 6.0 [19.4] 6.0 [14.5 [20.8] 39.6] 62.5 [25.1 [24.3 [14.2] 5.5 [14.3] 5.4] 4.4 [12.5 93.4 72.8] 7.9 [13.15 2790 [1317] .5] 40.10 x CFM x (1 – DR) x (dbE – 80)].1 76.8 [27.6 [19.6] 6.5 Power 102.7] 56.7] 54.4] 7.3 82.0 [12.5 84.06 71°F [21.8 65.4] 64.5 [21.3] 4.0] 5.4] 7.8 [28.7] 67.3] 37.8] 4.1] 5.4 [26.8 [24.4] 74.1] 7.0 [22.8 [14.2 [29.4 [22.2 [30.3 [12.2] 56.5 65.9] 81.7 90.0 86.5 [19.6 [12.3 89.6] 75 Sens BTUH [kW] 68.3 [23.2 [20.7 [29.8] Power E R Total BTUH [kW] 105 A T [40.4 [19.2 [26.9 105.1 78.8] 48.2] 5.5] 49.2 Total BTUH [kW] 105 Sens BTUH [kW] [40.5 [14.6 67.8] 7.5] 7.0 [25.9 [27.9 [21.0] 6.1 [20.3 [25.0] 91.7] 93.2] 64.2] 5.2 63.0 [15.2 83.6] 5.2 [20.1] 58.4 88.8 Power Total BTUH [kW] 102.2] 58.5] 6.5] [32.9 83.0] 8.1] 58.0 91.™ 21 .6 75.3 [17.1 83.4 [20.3 [21.6] 85 Sens BTUH [kW] 67.9] 4.9] 6.5 69.9 [11.7] 5.9] 69.7] 5.0 80.5 [23.8] 64.1 [22.3] 52.8 [14.9 81.4 Total BTUH [kW] 109.7 78.9] 5.8 92.7] 52.1 80.5] 6. [ ] Designates Metric Conversions Rely on Ruud.5 [27.6] 8.2 [20.4] 59.9] 73.2] 88.7°C] 2325 [1097] .1 [15.4 98.0] 54.3] 5.3 74.9 81.3 [27.1] 4.9] 59.2 [21.2] 76.5 [25.7] 5.2 [22.2] 6.0 [21.2 [16.5 [21.7 [21.6 87.6 [16.4 [16.0 [20.7 63.4] 6.4] 68.7 [21.3 [28.0 67.2] 50.6 79.8] 68.7 [24.8 [24.8] 7.5 [26.2] 6.2°C] 2325 [1097] .7 [25.2 [19.4 [24.7 [19.2 [22.6 [18.3 [30.7 [26.5 [28.4] 49.1 [17.7 [24.4] 6.6] 48.3 70.7 [17.3 [23.6 [23.8] 61.0 86.8 [19.3 [20.9] 6.0 [22.9 [22.0 [23.8] 6.4 [22.2] 43.2 Power Total BTUH [kW] 99.8 [27.6 72.9] 6.9 [23.5 [26.0] 49.6 101.0 [24.8 81.2°C] 2775 [1310] .6 87.8 99.6] 58.2 [17.7 [18.2 [32.5] 5. adjust the sensible capacity from the table by adding [1.1 [21.2 [14.7 76.9 [18.2 [18.6 [28.2 67.3 [19.Gross Systems Performance Data RLNL-B Series GROSS SYSTEMS PERFORMANCE DATA—B073 ENTERING INDOOR AIR @ 80°F [26.3] 53.5 [13.1] 62.5] 5.2] 56.5 75.8] 68.0 94.4] 84.4 [25.9] 7.5] 50.0 74.9 [15.9 98.9 97.3 [15.7 [25.1 [19.1] 67.1] 61.9 [21.1 86.6] 73.6] 4.3 [14.4] 5.6] 4.0] [23.4] 5.0] 60.1] 69.3] 7.4] 45.9 [25.8] 7.9 [26.6 75.1] 6.2 [21.0 [15.7] 8.9 [21.0 86.8 84.1 [28.0 [14.8 77.0 [20.6 81.9 [13.01 1860 [878] .3 82.6] 6.17 3600 [1699] .6 [26.5] 7.13 2440 1152] .2 [23.2 [15.4 80.5 56.8 [22.7 [16.5 [22.06 63°F [17.1] 90.7 72.6] 4.8 [22.0] 5.5] 69.1 Total BTUH [kW] 105.4] 65.13 2440 1152] .9] 6.3] 8.0] 95 Sens BTUH [kW] 65.1] 80 Sens BTUH [kW] 68.6] Sens BTUH [kW] Power U R Total BTUH [kW] E 110 Sens BTUH [kW] [43.2 [18.9] 45.4 [11.7 81.4 77.1] 47.9] 43.9] 6.3 [25.7] 60.5] 54.7] 63.6] 5.8 94.1 [12.0 [22.06 67°F [19.1] 66.0 [20.9 [20.2 89.17 Total BTUH [kW] 111.8 [21.3 [20.3 [15.4 97.4] 5.1 71.4 [23.4 [15.5] 36.0 [12.9] 5.6 [23.8] 42.3] 57.6 [27.0] 5.9 [14.4] 6.2] 48.7 82.4] 6.6] 47.9] 54.7 69.3 [18.5 83.2 [18.4 64.2] 5.5] 75.8] 6.4] 6.8] 73.2 [19.7 [21.5] 50.2] 5.4] 6.5 101.3 99.2] 4.3] 46.8] 5.8 [19.5] 7.9] 79.2] 6.6] 50.6 [17.2] 6.5 [30.9] 5.2] 5.2 [14.5] 54.2] 42.9 72.8 [25.8] 54.6 [24.9 [22.4 [22.0 [12.5] 6.3] 5.4 [12.9 [29.9] 6.7] 67.3 [17.6 93.8 [19.6 [22.3] 52.9] 7.2 86.8 [14.7] 6.3] °F Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.8 [17.6 [16.6 [15.0 [24.1 71.7 101.5] 54.6 [23.1 [13.7 [31.1 [18.5 [14.8] 74.4 68.9 GROSS SYSTEMS PERFORMANCE DATA—B090 ENTERING INDOOR AIR @ 80°F [26.7 [13.7 [30.9] 62.9 66.7] 44.2] 6.1] 66.4] 84.6 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.8 [16.9] 64.8 [29.8 [20.2 97.8 Total BTUH [kW] 107.7] 7.7 [21.9 [17.1] 54.1] 7.06 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C].0] 59.4] 50.5] 52.1] [35] 7.2] 7.5] 65.0] 4.5 [26.06 67°F [19.1 [22.3] 67.1 90.1] Power 2790 [1317] .7] 8.7 90.1] 57.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.5 [28.0] 75.0 75.7] 62.0] 84.9 [16.3 [25.7] 5.8 [24.9 [19.3] 42.9 [18.3] 57.5 [16.1 [17.8 79.7 [21.1 [22.1] 62.6] 45.2 [25.6 99.3 [23.0 [24.3] 55.9] 5.0 69.8 [27.9] 6.4 74.4 [26.0 [10.1] 4.8 [19.9] 6.6] Power 95.4 91.2 96.3] 8.4] 6.4 [14.9] 90 Sens BTUH [kW] 66.9 [12.2 [16.9 [18.1] 85.1 79.9] 5.3 [29.9] 45.9 [18.6] 6.4] Power D R Total BTUH [kW] Y 90 Sens BTUH [kW] [32.9] 5.8 71.7 [20.3 [20.17 3600 [1699] .9] 4.6] 34.1 [19.9 70.3] 63.9] [29.6 [17.13 2440 1152] .9 64.2] 66.5 81.5] 5.3 92.4 [24.6 [18.1] 6.5 [26.4°C] 2325 [1097] .6 [26.7 70.5] 8.4 [17.5 [11.7] 7.7°C] dbE ➀ wbE CFM [L/s] DR ➀ 71°F [21.2] 5.5] 7.1 [15.3] 6.9] 8.1 [22.0] 50.8 [12.8] 8.0 [28.9 [21.4 [22.2 [17.0 [16.2 [24.5] 52.3] 8.2 71.1] 44.5 [22.9] 8.8] 6.8] 58.5 78.7 74.5 [27.3 [14.5 [13.9 [17.9 [26.7] 83.5 [24.9] 6.0 [19.7 79.8] 57.0] 6.0 [30.2] 6.6 [20.7] 8.5 [20.2 [19.5 [20.9 82.6 [16.6 84.5 [11.7] 5.7] 4.8] 60.4 [24.9 88.9] 55.2 [27.5] 62.0 [17.7] D Power O O Total BTUH [kW] 85 R Sens BTUH [kW] [29.6 66.1 [16.9 [20.5 [19.7 [32.2 90.2] 48.2] 4.0] 60.1 [22.8 [23.2 73.1 [14.3 [29.6] 8.15 2790 [1317] .9] 6.6 [24.9] 7.6 [19.5 [23.8 84.2] 93.6 [14.8 [20.4 [24.6] 4.8 [28.6] 8.5 84.9 [19.8 77.1] 41.0] 57.5] 6.4 [28.1 [21.6] 6.6 [13.6] 56.5 [18.5] 69.2 [12.4 [25.5] 61.3] 60.7] 6.2] B Power U Total BTUH [kW] L 95 B Sens BTUH [kW] [35] Power T E Total BTUH [kW] 100 M Sens BTUH [kW] P [37.1 87.1] 38.8 96.6 58.6] 49.8] 58.2 [18.01 1860 [878] .06 63°F [17.3] 8.8 85.8] 77.7 [23.6 [18.9 [20.2] 67.5 88.4 77.9 [30.8 [26.0 [23.7 85.5 95.0 [15.9] 4.4] 6.4] 66.8 60.5 O U T D O O R D R Y B U L B T E M P E R A T U R E DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 3600 [1699] .1 Power 104.9] 5.2] 5.7 [31.9] 5.7] 46.2 [31.6 Power 99.6 107.2 [24.2] 7.4 72.2] 6.6] 5.9 [19.1 77.8 91.0 100.1] 53.1] 100 Sens BTUH [kW] 63.8 [23.6 90.7 [21.8] 77.6] 5.1] 8.2] 5.8] 46.8 62.4 [22.7 97.6 60.0] [26.9 85.2 [18.1 75.2 [15.2 78.5] [37.2 [17.3 [22.9] 57.9 [17.8 [27.5 [27.4 [18.6 [20.6 [25.0 [19.7] 48.4 [28.2] 7.4 [29.7] 6.2 80.15 92.3] 71.8 [11.7°C] dbE ➀ wbE CFM [L/s] DR ➀ Total BTUH [kW] 75 Sens BTUH [kW] [23.4 [26.4] 5.4 [15.1] 49.8 [17.8 [19. 7 [34.2 95.2 [25.9] 108.5 [35.0 [17.5] 8.4 114.7 100.2] 92.9 [29.6] 94.4 [32.6 104.6 [36.3 [37.5 [31.5] 109.5] 100.0 [32.3] 80 Sens BTUH [kW] 71.3 137.0] [26.5 [24.7 106.2 [20.0] 11.5] 8.3 [29.4 [16.3] 8.2] 108.2 [22.8] 67.2 [°C] Total BTUH [kW] 124.8 [36.4°C] 3200 [1510] .9 130.2] 7.™ NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C].4 [20.9] 111.3 [23.2] 51.3] 7.2 100.2] 110.0 103.8] 8.6 98.2] [23.3 Total BTUH [kW] 112.6 99.4 96.2] 69.7°C] dbE ➀ wbE CFM [L/s] DR ➀ 71°F [21.4 [37.0] 88.3 [16.1 102.7 131.9 [33.1] 11.5] 61.3] 6.0 [36.4] [32.7 [25.3 [40.1] 90.7] 105 Sens BTUH [kW] 90.7 108.0 [29.2 128.0 129.8] 71.8 [33.8 108.8] 100 Sens BTUH [kW] 93.6 [29.8 [31.4 [22.4 95.1 [32.07 4800 [2265] 0 63°F [17.0 [22.3 105.9 99.9 [23.9 [30.8] 79.3 104.8] 7.0 [27.3 [26.0 119.8] 8.5] [23.0] 11.08 Total BTUH [kW] 113.2 132.4 91.2 [19.2 138.3] 7.6 78.2 [27.5 [17.0 [36.3 [22.5] 8.4 105.3 87.5 [33.4 85.2] 8.2 [25.2] 6.8 [33.1 113.4] 7.9] 86.5 [32.0] 10.2 [27.5 127.8 [20.3 110.4 [37.1 97.0 120.5 [38.2] 6.5 [26.6] 106.5 93.4 [40.1 95.8 [38.03 3200 [1510] .5 [29.6 [40.2] 11.3] 9.0 Total BTUH [kW] 113.9 [15.4] 10.7] 56.1 [25.0 [25.8] 79.6] 9.2] 105 Sens BTUH [kW] 68.7 [26.6] 78.5 114.4 Total BTUH [kW] 109.3] 86.8 101.9 104.7 [35.0 135.7 [28.0] 7.1 105.8 [20.7 [29.6 132.1 [28.8] 75 Sens BTUH [kW] 99.4] 7.1 [31.1] [40.2] 8.1] 6.1] 88.6 [18.7 [26.3 101.2] 93.6 [25.3] °F Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.6] 72.9 [27.7] 8.6 [21.1] 9.4 [20.9] 7.0 [22.7 [26.2 [27.6 125.6 [21.1] 82.3] 10.1 129.7 [31.4 116.1 [30.9 122.7] 97.1] 8.0] 80.2 [35.9] 97.7 104.3] 85.7 [35.0 [34.5 [23.6 [27.5 [26.1 [33.3 108.5] 77.3 104.7] 100.3] 87.0 [36.7] [37.3 99.3 122.0 [20.6 122.0 [28.4] 10.4 [26.6] 103.6] 51.0] 7.4] 77.1 90.6 105.0 [28.6 [15.1 94.9] [46.7] 90 Sens BTUH [kW] 72.9] 71.0] 9.3] 8.5 [28.5 [30.7] 76.9] 7.5] 9.0 [29.1 [30.7 [29.5 [18.6 120.8 [37.0] 9.4 [30.2 99.0 [28.2] 9.3 111.6] 7.07 4800 [2265] 0 67°F [19.1 [27.3 [39.8 109.0] 10.7] 104.4 [30.9 [22.4] 7.2] 87.7 96.2 101.8 [27.9 [14.2] [35] Power 7.1 [27.7] 7.1 [27.0] 48.4 [25.4 [22.3] °F Power 11.9] 66. adjust the sensible capacity from the table by adding [1.8] 77.2] 82.6 [26.5 123.9] 92.0 [41.7 [35.2] 9.7] 102.1] 11.7 [40.2 [28.5 101.1 [30.2] 8.5 90.6 94.1 [29.3] 70.3 [27.9 [17.7] 61.4 [20.4 119.4 [37.9 [26.6 [25.5] 6.7 [30.4 [13.1] 89.4 90.2] 7.6] 7.6 [14.0] 6.9 [32.1 [30.8] 8.8] 55.0 [39.0 125.1] [26.4] 8.2 [31.9] 94.7 [30.6 [35.6 [30.1 114.5] 8.8 [33.9] 68.4] 90.8] 67.4 95.9] 65.0 [23.3] 6.8 [33.2 101.0 90.8] 8.6 118.9 135.08 4100 [1935] 0 63°F [17.1 [25.2 126.7 [20.7 81.3 [23.9] 7.7] 8.5] 7.4] 130.9 [29.3] 10.4 104.7 [23.6 132.0] 6.2 O U T D O O R D R Y B U L B T E M P E R A T U R E DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 4800 [2265] 0 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input 22 Rely on Ruud.6] 61.7 [36.2 [27.0 [27.03 3200 [1510] .1] 102.3 [38.6 [28.1] 6.3 [20.1 [30.5] 99.8 [32.9] 95.2] 6.1 [31.9] 8.2 113.3] 117.6 [23.03 3200 [1510] .3 100.2 [33.8 140.7 130.2] 6.8 125.0 [25.3 88.6] 8.8] 68.8] 7.6] 8.4 [29.4] 85 Sens BTUH [kW] 98.1 [28.7 [24.7] 9.4 [30.2 [30.0] 78.0 [32.0] 9.5] 107.4] 9.5 [14.7 102.2 [26.7] Power 7.2] 100 Sens BTUH [kW] 70.6] 10.9 121.9 [34.9] 75.7 [29.6] 69.0 [39.7] 7.8 87.4 [25.9 [33.6] 52.4] Power 7.9] 50.7 [33.6] Power 10.7 [28.2 [38.6] [40.2 [21.5 [18.2] 79.9 94.2 122.3] 79.5 [15.3] 7.1 [25.1 [25.9] 6.4 [28.6 122.0] 94.8] 114.6] 69.5 [21.3] [29.9 [28.8] Power 9.6 [20.6 136.4] [32.2 [27.4 118.2 [32.5] 43.9] 9.1 97.05 2700 [1274] .3] 91.1 97.1 134.0 [25.8] 7.6 [33.3 [18.5] 97.8] 6.6] 88.0 [22.9] Power 7.7] 69.3 [19.3 [43.4 [34.6 [19.Gross Systems Performance Data RLNL-B Series GROSS SYSTEMS PERFORMANCE DATA—B102 ENTERING INDOOR AIR @ 80°F [26.9] 10.6] 81.8 [21.1] 85 Sens BTUH [kW] 72.5] 77.5 [23.0] 93.0] 7.6 [29.6] 7.2] Power 7.4] 78.0] 8.4 108.1] 7.0 [27.8] 50.3 [38.3] 11.3 [37.6] 10.9 85.3] 97.8] 46.5] 58.7 [31.5 109.7] 74.2 [20.3] 7.4 128.7] Power 6.2] 9.2] 9.3 [16.0 103.0] 7.9 [38.9] 73.9 [35.2 94.9 [21. [ ] Designates Metric Conversions .07 Total BTUH [kW] 149.5 [35.4] 117.3 Total BTUH [kW] 132.1 [25.1] Power 11.6] 94.8 [38.2°C] 3200 [1510] .2 [28.7 [20.8 [27.8] 106.9 [20.3 [28.7 [34.5 [34.4 [31.1 [30.9] 117.8] 96.3] 98.2°C] 3750 [1770] .1 [31.4] 74.2 [25.1 [41.1] 71.1 [30.0 125.3] 9.5 98.9 [31.3 [37.7] 104.1] 6.7] 57.7] 11.5 89.8 Total BTUH [kW] 103.8 102.8 [39.7 [30.4 [23.6 [25.0 [30.1] 8.8 [37.0 [21.2 [30.3] [37.2 94.6] 76.9 [30.7 [26.8 [17.2] 79.6] Power 8.6] 97.0 93.7°C] 3200 [1510] .5 [31.4] 9.4 [33.4°C] 3750 [1770] .8] 63.4 [25.0] 126.08 4100 [1935] 0 67°F [19.3 [18.4 [29.0 [31.6 [27.8 [28.5] 8.5 [35.3 [21.7] 8.4] 75 Sens BTUH [kW] 69.3] 6.7 [12.9 Total BTUH [kW] 128.1] 84.8 [26.8] Power 8.5] 6.2] 68.8 [15.8] 103.5] 7.8] 10.9 107.4] 8.05 2700 [1274] .4] 8.5 [22.9 [33.3] 7.0 [41.0 [40.7] 68.8 [31.9 118.2] 123.7] 76.9 [30.0] 8.1] 8.8 [25.5 [30.4] 10.3] 7.8] 10.6] 10.1] Power 4100 [1935] 0 99.1] 59.0] 9.8 [37.3 [34.7 [28.2 [26.1 139.4] 9.9] 85.6] 6.9 [36.6] 9.7] [29.5 128.1] 8.3 [27.1] 80 Sens BTUH [kW] 99.9] 6.5] 58.8 [26.7] 9.9 [38.0 [28.2 [31.9 [31.8 86.9] 90.8] [43.3 91.1] 77.2] 8.0 [28.8] 9.5 [27.0] 93.3 [35.10 x CFM x (1 – DR) x (dbE – 80)].7 97.7 [28.4] Power 8.7 [22.7] 95 Sens BTUH [kW] 95.4 Total BTUH [kW] 135.1 [23.1] 7.7] 57.7 [19.9 89.8 117.9 [28.1] 8.7] 9.8] 64.3 Total BTUH [kW] 144.2] 9.8 115.7] 6.2] 11.1 [34.4 [24.8 Total BTUH [kW] 106.3] 49.7 112.9] 109.1 124.6 97.5 [21.3 [24.8] 88.9 116.4] 120.4 [34.9 [34.6] 116.5 [25.9] Power 6.5] 70.0] 105.1 [27.7 [26.3 [23.6 GROSS SYSTEMS PERFORMANCE DATA—B120 ENTERING INDOOR AIR @ 80°F [26.6 [20.9] 85.5 123.1 Total BTUH [kW] 110 Sens BTUH [kW] [43.5] 71.8] 6.7 [34.4] 115 Sens BTUH [kW] 85.8 109.2 106.1 [29.6] 11.2 [34.7°C] 3750 [1770] .8 [29.7 117.4] 7.7] 128.9] 87.4] 79.3 [27.1 105.0] 11.5] 82.9] 7.3 [35.6] 6.8 Total BTUH [kW] 147.7 [21.0 [24.2] 81.6] 51.4 119.6] 7.0] 65.9 [24.0] 98.2 [26.8 Total BTUH [kW] 139.4] 113.9 [28.7 [30.5] 78.7 Total BTUH [kW] 142.6] 90 Sens BTUH [kW] 96.9 [21.7] 96.6] 7.4 [23.7°C] ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.9 126.7] 6.1 107.7 [42.1] 8.7 [23.7 98.3 [36.0 105.5 137.2 [29.8 [29.2 [37.5 110.2 83.1 [39.7] 75.6] 110 Sens BTUH [kW] 88.5] 104.8 [28.0] 85.7 [32.1] 6.6 101.5] 7.6 [22.9] [35] Power 9.1] 95 Sens BTUH [kW] 72.6 [36.1] 7.1 [32.2 [35.5] 9.7 83.0] 88.1 117.1 [29.2 [43.8] 6.9 111.6 [36.0 99.9] 113.5 [37.7 [32.05 2700 [1274] .5] 8.1] 92.2] Power 8.0 [32.3 [32.5] 6.7] 7.1] 8.5] 6.6 [31.7 104.6 [29.2 110.9 [30.7 [24.7 Total BTUH [kW] 111.8] 49.8 [28.3] 87.3 [14.8 [14.9] 8.5 [25.6] 86.1] 9.3 142.1 [27.3 [31.0 [19.3 [31.7 129.8 [22. Gross Systems Performance Data RLNL-B Series GROSS SYSTEMS PERFORMANCE DATA—B151 ENTERING INDOOR AIR @ 80°F [26.7°C] ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 4225 [1994] .03 3800 [1793] .06 5800 [2737] 0 67°F [19.4°C] 4225 [1994] .03 3800 [1793] .06 5800 [2737] 0 63°F [17.2°C] 4225 [1994] .03 3800 [1793] .06 Total BTUH [kW] 196.8 [57.7] 75 Sens BTUH [kW] 135.5 [39.7] [23.9] Power 10.2 184.4 [54.0] 103.0 [30.2] 9.9 181.0 [53.0] 94.9 [27.8] 9.8 186.8 [54.7] 156.7 [45.9] 10.0 175.0 [51.3] 121.7 [35.7] 9.7 171.8 [50.3] 112.9 [33.1] 9.6 178.6 [52.3] 177.9 [52.1] 9.7 167.3 [49.0] 140.2 [41.1] 9.4 164.2 [48.1] 130.7 [38.3] 9.3 Total BTUH [kW] 192.1 [56.3] 80 Sens BTUH [kW] 132.7 [38.9] [26.7] Power 10.7 179.9 [52.7] 100.8 [29.6] 10.3 176.6 [51.8] 92.9 [27.2] 10.3 182.1 [53.4] 153.9 [45.1] 10.5 170.6 [50.0] 119.6 [35.1] 10.1 167.4 [49.1] 110.9 [32.5] 10.0 173.9 [51.0] 173.9 [51.0] 10.2 162.9 [47.7] 138.2 [40.5] 9.9 159.9 [46.9] 128.9 [37.8] 9.8 Total BTUH [kW] 187.2 [54.9] 85 Sens BTUH [kW] 129.7 [38.0] [29.4] Power 11.2 175.3 [51.4] 98.6 [28.9] 10.9 172.1 [50.4] 90.9 [26.7] 10.8 177.2 [51.9] 151.1 [44.3] 11.0 166.0 [48.6] 117.5 [34.4] 10.6 162.9 [47.7] 109.0 [32.0] 10.5 169.0 [49.5] 169.0 [49.5] 10.7 158.3 [46.4] 136.0 [39.9] 10.4 155.4 [45.5] 126.9 [37.2] 10.3 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 182.1 [53.4] 126.8 [37.2] 11.8 176.8 [51.8] 123.6 [36.2] 12.3 171.3 [50.2] 120.3 [35.3] 13.0 170.5 [50.0] 96.4 [28.3] 11.4 165.6 [48.5] 94.1 [27.6] 11.9 160.4 [47.0] 91.6 [26.9] 12.5 167.4 [49.1] 88.9 [26.1] 11.3 162.5 [47.6] 86.7 [25.4] 11.8 157.5 [46.2] 84.5 [24.8] 12.4 172.1 [50.4] 148.0 [43.4] 11.5 166.8 [48.9] 144.9 [42.5] 12.1 161.3 [47.3] 141.6 [41.5] 12.7 161.2 [47.2] 115.2 [33.8] 11.2 156.2 [45.8] 112.8 [33.1] 11.7 151.0 [44.3] 110.3 [32.3] 12.3 158.2 [46.4] 106.9 [31.3] 11.1 153.3 [44.9] 104.7 [30.7] 11.6 148.3 [43.5] 102.5 [30.0] 12.2 163.9 [48.0] 163.9 [48.0] 11.3 158.6 [46.5] 158.6 [46.5] 11.9 153.1 [44.9] 153.1 [44.9] 12.5 153.5 [45.0] 133.7 [39.2] 10.9 148.5 [43.5] 131.3 [38.5] 11.5 143.3 [42.0] 128.8 [37.8] 12.1 150.7 [44.2] 124.8 [36.6] 10.8 145.8 [42.7] 122.6 [35.9] 11.4 140.7 [41.2] 120.3 [35.3] 12.0 Total BTUH [kW] 165.6 [48.5] 105 Sens BTUH [kW] 116.9 [34.3] [40.6] Power 13.6 155.1 [45.5] 89.1 [26.1] 13.2 152.2 [44.6] 82.2 [24.1] 13.0 155.6 [45.6] 138.2 [40.5] 13.4 145.7 [42.7] 107.8 [31.6] 12.9 143.0 [41.9] 100.2 [29.4] 12.8 147.4 [43.2] 147.4 [43.2] 13.1 138.0 [40.4] 126.3 [37.0] 12.7 135.5 [39.7] 118.0 [34.6] 12.6 149.6 [43.8] 86.5 [25.4] 13.8 143.9 [42.2] 83.8 [24.6] 14.5 146.8 [43.0] 79.8 [23.4] 13.7 141.2 [41.4] 77.3 [22.7] 14.4 149.7 [43.9] 134.7 [39.5] 14.0 143.6 [42.1] 131.0 [38.4] 14.7 140.2 [41.1] 105.2 [30.8] 13.6 134.5 [39.4] 102.5 [30.0] 14.3 137.6 [40.3] 97.8 [28.7] 13.5 132.0 [38.7] 95.3 [27.9] 14.2 141.5 [41.5] 141.5 [41.5] 13.8 135.4 [39.7] 135.4 [39.7] 14.5 132.5 [38.8] 123.7 [36.3] 13.4 126.8 [37.2] 121.0 [35.5] 14.1 130.1 [38.1] 115.6 [33.9] 13.3 124.5 [36.5] 113.1 [33.2] 13.9 Total BTUH [kW] 110 Sens BTUH [kW] [43.3] °F Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 5800 [2737] 0 159.7 [46.8] 113.4 [33.2] 14.3 153.6 [45.0] 109.8 [32.2] 15.0 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. [ ] Designates Metric Conversions Rely on Ruud.™ 23 24 Rely on Ruud.™ — — — — — — — 805 831 858 886 — — — — — — — 751 813 878 947 0.1 [.02] RPM W — — — — — 802 826 852 877 904 931 — — — — — 706 764 826 890 958 1029 0.2 [.05] RPM W — — — 803 826 849 872 897 922 947 973 — — — 663 718 775 836 900 967 1037 1110 0.3 [.07] RPM W Model RLNL-B073 Voltage 208/230, 460, 575 — 3 phase 0 1119 1 1072 L 1.5 [1118.6] AK66 1VP-44 2 3 1019 967 — 808 828 850 871 894 916 940 964 989 1014 4 915 — 622 673 727 784 844 907 973 1043 1115 1190 0.4 [.10] RPM W 5 859 835 854 874 894 915 937 959 981 1005 1029 1053 880 899 918 937 957 978 999 1021 1044 1067 1091 1 1215 686 739 794 853 914 979 1047 1118 1191 1268 1349 1800 [849] 0.97 0.91 0.99 2000 [944] 0.96 0.94 0.99 2200 [1038] 0.99 0.97 0.99 2400 [1133] 1.00 1.00 1.00 [ ] Designates Metric Conversions NOTES: 1. Multiply correction factor times gross performance data. 2. Resulting sensible capacity cannot exceed total capacity. ACTUAL—CFM [L/s] TOTAL MBH SENSIBLE MBH POWER kW AIRFLOW CORRECTION FACTORS 6 TON [21.1 kW] 2600 [1227] 1.01 1.02 1.00 2800 [1277] 1.02 1.05 1.01 965 982 999 1017 1036 1055 1075 1095 1116 1137 1160 M 1.5 [1118.6] AK66 1VP-50 2 3 1163 1113 740 795 853 914 978 1045 1115 1188 1265 1344 1426 794 851 911 974 1041 1110 1183 1258 1337 1418 1503 4 1064 1005 1021 1037 1055 1072 1091 1110 1129 1149 1170 1191 5 1015 847 906 968 1034 1103 1174 1249 1327 1408 1492 1579 1043 1058 1074 1090 1107 1125 1143 1162 1181 1201 1221 898 960 1025 1093 1164 1238 1315 1395 1478 1565 1654 1079 1093 1108 1124 1140 1157 1174 1192 1211 1230 1250 949 1013 1080 1151 1224 1300 1380 1462 1548 1637 1728 1.1 [.27] RPM W 1113 1127 1141 1156 1171 1187 1204 1221 1239 1257 1276 999 1065 1135 1208 1283 1362 1444 1529 1616 1708 1802 1.2 [.30] RPM W 1048 1117 1189 1264 1342 1423 1507 1594 1684 1778 — 1177 1189 1201 1214 1228 1242 1257 1273 — — — DNA 0.06 [0.015] 0.04 [0.009] 0.08 [0.020] 0.05 [0.012] 0.03 [0.007] 0.08 [0.020] 0.07 [0.017] 0.04 [0.010] 0.08 [0.020] DNA 0.08 [0.020] 0.05 [0.011] 0.10 [0.020] DNA 0.09 [0.022] 0.05 [0.012] 0.11 [0.027] DNA 0.10 [0.025] 0.06 [0.014] 0.12 [0.030] DNA 0.071 [0.018] .037 [0.092] 3400 [1604] 1096 1167 1242 1319 1399 1482 1569 1658 — — — 1.4 [.35] RPM W Standard Indoor Airflow—CFM [L/s] 2800 3000 3200 [1321] [1416] [1510] Resistance—Inches Water [kPa] 0.051 0.055 0.060 0.065 [0.013] [0.014] [0.015] [0.016] .017 .020 .025 .031 [0.042] [0.050] [0.062] [0.077] 2600 [1227] DNA DNA 0.047 [0.12] 2400 [1133] 1146 1159 1172 1186 1201 1216 1231 1248 1265 1282 — 1.3 [.32] RPM W NOTE: Add component resistance to duct resistance to determine total external static pressure. DNA = Data not Available. Concentric Diffuser RXRN-FA65 or FA75 & Transition RXMC-CD04 Concentric Diffuser RXRN-AA61 or AA71 & Transition RXMC-CE05 Economizer 100% R.A. Damper Open Horizontal Economizer 100% R.A. Damper Open Horizontal Economizer 100% O.A. Damper Open Wet Coil Component COMPONENT AIR RESISTANCE, IWC 7.5 TONS [26.4 kW] 924 941 959 978 997 1017 1038 1059 1081 1103 1126 External Static Pressure—Inches of Water [kPa] 0.6 [.15] 0.7 [.17] 0.8 [.20] 0.9 [.22] 1.0 [.25] RPM W RPM W RPM W RPM W RPM W 0 1267 631 681 734 790 850 912 977 1046 1118 1192 1270 0.5 [.12] RPM W NOTES: 1. Factory sheave settings are shown in bold type. 2. Do not set motor sheave below minimum turns open shown. 3. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum E.S.P. 4. Drive data shown is for horizontal airflow with dry coil. Add component resistance to duct resistance to determine total E.S.P. Drive Package Motor H.P. [W] Blower Sheave Motor Sheave Turns Open RPM NOTE: L-Drive left of bold line, M-Drive right of bold line. 1800 [849] 1900 [897] 2000 [944] 2100 [991] 2200 [1038] 2300 [1085] 2400 [1133] 2500 [1180] 2600 [1227] 2700 [1274] 2800 [1321] Air Flow CFM [L/s] AIRFLOW PERFORMANCE—6 TON [21.1 kW] B073 1144 1217 1293 1373 1456 1541 1630 — — — — .017 [0.042] 0.11 [0.027] 0.06 [0.015] 0.13 [0.032] DNA 0.076 [0.019] 3600 [1699] 1206 1217 1228 1241 1254 1267 1282 — — — — 1.5 [.37] RPM W Indoor Airflow Performance RLNL-B Series 546 741 854 869 560 804 598 940 576 876 612 1011 592 954 628 1096 607 1030 643 1180 622 1112 658 1271 638 1202 672 1361 617 632 646 660 673 689 704 931 1010 1089 1168 1247 1344 1440 650 664 678 692 710 719 728 1024 1107 1189 1274 1306 1366 1426 1 682 2 650 L 2.0 [1491.4] BK110 1VP-44 3 4 620 587 5 555 6 523 612 624 635 648 660 673 685 713 722 731 739 748 757 645 656 667 680 708 725 734 743 751 760 769 777 786 1 869 729 791 853 923 993 1069 1144 1187 1247 1307 1368 1428 1488 2 838 812 878 945 1017 1069 1129 1189 1249 1309 1369 1430 1490 1550 890 950 1010 1070 1131 1191 1251 1311 1371 1431 1491 1552 1612 740 749 758 766 775 784 792 801 810 818 827 836 844 M 2.0 [1491.4] BK90 1VP-44 3 4 806 774 711 720 729 737 746 755 763 772 781 789 798 807 815 0.91 0.99 SENSIBLE MBH POWER kW 0.94 0.99 2800 [1321] 0.98 0.97 0.99 3000 [1416] 0.99 1.00 1.00 3200 [1510] 1.00 [ ] Designates Metric Conversions NOTES: 1. Multiply correction factor times gross performance data. 2. Resulting sensible capacity cannot exceed total capacity. 2600 [1227] 0.97 ACTUAL—CFM [L/s] TOTAL MBH 1.02 1.00 3400 [1604] 1.01 AIRFLOW CORRECTION FACTORS 7.5 TON [26.4 kW] 1.05 1.01 3600 [1699] 1.02 1.08 1.02 3800 [1793] 1.03 770 778 787 796 804 813 822 830 839 848 856 865 874 5 742 952 1012 1072 1132 1192 1253 1313 1373 1433 1493 1553 1613 1674 1076 1136 1196 1256 1316 1376 1437 1497 1557 1617 1677 1737 1797 1 1157 799 808 816 825 834 842 851 860 868 877 886 894 903 2 1106 828 837 846 854 863 872 880 889 898 906 913 920 928 857 866 875 883 892 906 913 921 928 935 943 950 957 1200 1260 1320 1380 1440 1688 1752 1816 1880 1944 2008 2072 2136 N 3.0 [2237.1] BK65 1VP-44 3 4 1056 1005 1138 1198 1258 1318 1378 1438 1498 1559 1619 1859 1923 1987 2051 887 895 914 921 928 936 943 950 957 965 972 979 986 5 954 6 904 1261 929 1538 958 1322 936 1602 965 1581 943 1666 972 1645 950 1730 980 1709 958 1794 987 1773 965 1858 994 1837 972 1923 1002 1901 979 1987 1009 1965 987 2051 1016 2029 994 2115 1023 2094 1001 2179 1031 2158 1009 2243 1038 2222 1016 2307 1045 1623 1687 1751 1816 1880 1944 2008 2072 2136 2200 2264 2328 2393 987 995 1002 1009 1016 1024 1031 1038 1045 1053 1060 1067 1075 1709 1773 1837 1901 1965 2029 2093 2157 2222 2286 2350 2414 2478 DNA 0.06 [0.015] 0.04 [0.009] 0.08 [0.020] DNA 0.05 [0.012] 0.03 [0.007] 0.08 [0.020] DNA 0.047 [0.12] 1794 1858 1922 1986 2050 2115 2179 2243 2307 2371 2435 2499 2563 1046 1053 1061 1068 1075 1082 1090 1097 1104 1111 1119 1126 1133 1879 1944 2008 2072 2136 2200 2264 2328 2392 2456 2521 2585 2649 0.07 [0.017] 0.04 [0.010] 0.08 [0.020] DNA 0.08 [0.020] 0.05 [0.011] 0.10 [0.020] DNA 0.09 [0.022] 0.05 [0.012] 0.11 [0.027] DNA Standard Indoor Airflow—CFM [L/s] 2800 3000 3200 [1321] [1416] [1510] Resistance—Inches Water [kPa] 0.051 0.055 0.060 0.065 [0.013] [0.014] [0.015] [0.016] .017 .020 .025 .031 [0.042] [0.050] [0.062] [0.077] 2600 [1227] 1017 1024 1031 1038 1046 1053 1060 1068 1075 1082 1089 1097 1104 NOTE: Add component resistance to duct resistance to determine total external static pressure. DNA = Data not Available. Concentric Diffuser RXRN-FA65 or FA75 & Transition RXMC-CD04 Concentric Diffuser RXRN-AA61 or AA71 & Transition RXMC-CE05 Economizer 100% R.A. Damper Open Horizontal Economizer 100% R.A. Damper Open Horizontal Economizer 100% O.A. Damper Open Wet Coil Component 2400 [1133] COMPONENT AIR RESISTANCE, IWC 7.5 TONS [26.4 kW] 6 710 1014 1074 1134 1194 1254 1315 1375 1435 1495 1555 1615 1675 1735 1965 2029 2093 2157 2221 2285 2350 2414 2478 2542 2606 2670 2734 0.10 [0.025] 0.06 [0.014] 0.12 [0.030] DNA 0.071 [0.018] .037 [0.092] 3400 [1604] 1075 1083 1090 1097 1104 1112 1119 1126 1134 1141 1148 1155 1163 2050 2114 2178 2243 2307 2371 2435 2499 2563 2627 2691 2756 2820 .017 [0.042] 0.11 [0.027] 0.06 [0.015] 0.13 [0.032] DNA 0.076 [0.019] 3600 [1699] 1105 1112 1119 1127 1134 1141 1148 1156 1163 1170 1178 1185 1192 External Static Pressure—Inches of Water [kPa] 0.5 [.12] 0.6 [.15] 0.7 [.17] 0.8 [.20] 0.9 [.22] 1.0 [.25] 1.1 [.27] 1.2 [.30] 1.3 [.32] 1.4 [.35] 1.5 [.37] 1.6 [.40] 1.7 [.42] 1.8 [.45] 1.9 [.47] 2.0 [.50] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W NOTES: 1. Factory sheave settings are shown in bold print. 2. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum E.S.P. 3. Do not operate above blower RPM shown as motor overloading will occur. 4. Do not set motor sheave below one turn open. Drive Package Motor H.P. [W] Blower Sheave Motor Sheave Turns Open RPM NOTE: L-Drive left of bold line, M-Drive right of bold line. 3000 [1416] 3100 [1463] 3200 [1510] 3300 [1557] 3400 [1605] 3500 [1652] 3600 [1699] Capacity 7.5 Ton [26.4 kW] Air Flow 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] CFM [L/s] RPM W RPM W RPM W RPM W 2400 [1133] — — — — 540 580 582 664 2500 [1180] — — — — 552 633 593 717 2600 [1227] — — — — 564 687 603 769 2700 [1274] — — 539 670 577 744 614 828 2800 [1321] — — 554 733 590 801 625 887 2900 [1369] — — 569 801 604 866 638 956 AIRFLOW PERFORMANCE—7.5 TON [26.4 kW] RLNL-B090/C090 MODELS Indoor Airflow Performance RLNL-B Series Rely on Ruud.™ 25 0 [.3 [.5 TON [29.03 1.01 1.010] 0.060 0.13 [0.21 [0.009] 0.092] 0.027] 0.040] DNA 0.22] 1. Factory sheave settings are shown in bold print.27] 1.12 [0.5 TON [29.5 [.18 [0.05 0.31 0.25] 1.6 [.020] 0. 2600 [1227] ACTUAL—CFM [L/s] 1. 2.05] 0.020] 0.07] 0.8 [.10 0.07 [0.13 [0.015] 0.052] 0.99 0.12 0.076 [0.020] 3800 [1793] 1068 1075 1082 1090 1097 1104 1111 1119 1126 1133 1140 1147 — — — Standard Indoor Airflow—CFM [L/s] 3000 3200 3400 3600 [1416] [1510] [1604] [1699] Resistance—Inches Water [kPa] 0.03 1.020] 0.9 [.4 [.99 3200 [1510] 1. Damper Open Horizontal Economizer 100% R.4] BK90 1VP-44 3 4 791 757 705 713 722 731 739 748 757 782 796 809 823 836 708 717 725 734 743 761 760 769 777 786 810 823 837 850 864 737 748 755 763 772 781 789 798 807 815 837 851 864 878 922 6 690 1009 1069 1129 1189 1249 1309 1369 1430 1490 1550 1733 1816 1899 1981 2064 0.065 0.3 [.9 [.087 [0.A.24 [0.055 [0.045] 0.01 3600 [1699] [ ] Designates Metric Conversions NOTES: 1.17] 0. Damper Open Horizontal Economizer 100% O.42] 1.042] 2600 [1227] 1966 2050 2115 2179 2243 2307 2371 2435 2499 2563 2751 2870 2988 3107 3226 2072 2136 2200 2264 2328 2392 2456 2521 2585 2649 2864 2983 — — — 2157 2221 2285 2350 2414 2478 2542 2606 — — — — — — — DNA 0.50] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W 5 723 1127 1187 1247 1307 1368 1428 1488 1659 1741 1824 1907 1990 0.015] 0.8 [.P.024] [0.30] 1.08 [0.017] 0.09 0.S.071 0. Drive Package Motor H.98 3000 [1416] 0.1 [.093 [0.013] 0.15 [0.051 [0.08 [0.04 [0.050] 2800 [1321] DNA 0.10] CFM [L/s] RPM W RPM W RPM W RPM W 2700 [1274] — — — — — — — — 2800 [1321] — — — — — — — — 2900 [1369] — — — — — — — — 3000 [1416] — — — — — — — — 3100 [1463] — — — — — — — — 3200 [1510] — — — — — — 693 1185 3300 [1557] — — — — — — 701 1246 3400 [1605] — — — — 681 1244 710 1306 3500 [1652] — — 673 1270 690 1304 719 1366 3600 [1699] — — 686 1352 698 1364 728 1426 AIRFLOW PERFORMANCE—8.09 [0.9 kW] 1.042] 0.030] [0.4 [. 2.99 0.02 3800 [1793] AIRFLOW CORRECTION FACTORS 8.05 1.030] 0.082 [0.025] [0.032] 0.5 Ton [29.94 0. 3.014] 0.2 [.08 0.11 [0.022] [0.014] [0.20 [0.04 [0.5 TON [29.016] [0.021] 0.A.023] 4200 [1982] 1127 1134 1141 1148 — — — — — — — — — — — External Static Pressure—Inches of Water [kPa] 0.17 [0.12] RPM W — — — — — — NOTES: 1.9 kW] Air Flow 0. Concentric Diffuser RXRN-FA65 or FA75 & Transition RXMC-CD04 Concentric Diffuser RXRN-AA61 or AA71 & Transition RXMC-CE05 Economizer 100% R. 4.9 kW] Indoor Airflow Performance RLNL-B Series .16 [0.™ 672 686 699 713 726 1361 1443 1526 1609 1692 700 713 727 740 754 1435 1518 1601 1683 1766 727 741 754 768 781 1510 1592 1675 1758 1841 755 768 782 795 809 1584 1667 1750 1832 1915 1 860 2 824 L 2.01 1.08 [0.9 kW] M 3.06 [0.03 4000 [1888] 796 804 813 822 830 839 848 856 865 874 933 940 948 955 963 2 1098 1132 1192 1253 1313 1373 1433 1493 1553 1613 1674 1882 1965 2015 2085 2204 1.062] [0.37] 1.04 4200 [1982] 766 775 784 792 801 810 818 827 836 844 865 878 927 935 942 1 1148 1070 1131 1191 1251 1311 1371 1431 1491 1552 1612 1808 1890 1973 2056 2091 825 834 842 851 860 868 877 886 894 903 953 960 968 975 983 1256 854 1316 863 1376 872 1437 880 1497 889 1557 898 1617 906 1677 913 1737 920 1797 928 1956 973 2075 981 2194 988 2312 996 2431 1003 883 892 906 913 921 928 935 943 950 957 993 1001 1008 1016 1024 5 949 1318 1378 1438 1498 1559 1619 1856 1923 1987 2051 2070 2189 2307 2426 2545 921 928 936 943 950 937 968 972 979 986 1002 1016 1029 1043 1056 6 899 1380 1440 1688 1752 1816 1880 1944 2008 2072 2136 2183 2302 2421 2539 2658 1645 1709 1773 1837 1961 1965 2029 2094 2158 2222 2297 2416 2534 2653 2772 950 958 965 972 979 987 994 1001 1009 1016 1030 1043 1057 1070 1084 1730 1794 1858 1923 987 2051 2115 2179 2243 2307 2410 2529 2648 2767 2885 980 987 994 1002 1009 1018 1023 1031 1038 1045 1054 1062 1069 1077 1084 1816 1880 1944 2008 2072 2136 2200 2264 2328 2393 2524 2643 2761 2880 2999 1009 1016 1024 1031 1038 1045 1053 1060 1067 1071 1075 1082 1090 1097 1105 1901 1965 2029 2093 2157 2222 2286 2350 2414 2478 2637 2756 2875 2994 3112 DNA 0.017] 0.99 TOTAL MBH SENSIBLE MBH POWER kW 0.06 0.09 1.036] 0.88 0.15] 0. Damper Open Wet Coil Component COMPONENT AIR RESISTANCE. 3700 [1746] 3800 [1793] 3900 [1841] 4000 [1888] 4100 [1935] Capacity 8.97 2800 [1321] 0.06 [0.0 [2237.1] BK65 1VP-44 3 4 1049 999 1194 1254 1315 1375 1435 1495 1555 1615 1675 1735 1896 2003 2080 2199 2318 2243 2307 2371 2435 — — — — — — — — — — — 0.027] [0. [W] Blower Sheave Motor Sheave Turns Open RPM NOTE: L-Drive left of bold line.11 0.A.02] 0.00 1.044] DNA 0.97 1.00 1. Multiply correction factor times gross performance data. Do not set motor sheave below one turn open.2 [.40] 1.10 0.14 [0.26 Rely on Ruud.91 0.P.011] [0.20] 0.05 0.07 1.015] [0.00 0.17 DNA DNA DNA [0.7 [.032] 1038 1046 1053 1060 1068 1075 1082 1089 1097 1104 1111 1119 1127 1135 1144 NOTE: Add component resistance to duct resistance to determine total external static pressure.035] 0.018] [0.019] 0. Do not operate above blower RPM shown as motor overloading will occur. IWC 8.18 [0.00 3400 [1605] 1.060] 0.022] 4000 [1888] 1097 1104 1112 1119 1126 1134 1141 1148 — — — — — — — 0.6 [.07 [0.0 [.5 [.45] 1.02 1.012] [0.96 0.077] [0.35] 1. Resulting sensible capacity cannot exceed total capacity. M-Drive right of bold line. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum E.7 [.25 0.1 [.37 DNA [0.020] [0. DNA = Data not Available.47] 2.32] 1.0 [1491. 16 [0.05] 0.2 kW] 1.15 [0.00 4200 [1982] [ ] Designates Metric Conversions NOTES: 1.4 [.A.037] 0.50] 2. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum E.17] 0. IWC 10 TON [35. M-Drive right of bold line.07] 0.093 0.1 [.032] [0.02] 0.024] 0.P.9 [.15 0.91 0.047] DNA 0. Damper Open Horizontal Economizer 100% O. 2.17 [0.01 1. Multiply correction factor times gross performance data.2 kW] Air External Static Pressure—Inches of Water [kPa] Flow CFM [L/s] 0. 4.020] [0.04 1.22] 1.3 [.105 [0.021] 0.8 [. 2.030] DNA DNA 0.025] 0.0 [.10 [0.2 kW] 1813 1892 1956 2075 2194 2312 2431 2550 2669 2787 2906 3025 3143 3262 2 1089 938 945 953 960 968 975 983 990 998 1006 1013 1021 1028 1036 4800 [2265] 1791 1874 1896 2003 2080 2199 2318 2438 2555 2674 2793 2911 3030 3149 — — — — 657 1170 715 1245 742 1319 770 1394 797 1468 825 1543 852 1617 880 1692 956 1698 976 1703 996 1817 1017 1930 1037 2044 1057 2157 1077 2271 1098 2384 1118 2498 1138 2611 1159 2725 1179 2838 — — 673 1179 701 1253 728 1328 756 1402 783 1477 811 1551 838 1626 866 1700 943 1705 963 1708 948 1822 976 1935 1024 2049 1044 2162 1065 2276 1085 2390 1105 2503 1125 2617 1146 2730 1166 2844 1186 2957 — — 687 1261 714 1336 742 1410 769 1485 797 1559 824 1634 852 1708 879 1763 950 1811 971 1827 962 1941 989 2054 1032 2168 1052 2281 1072 2395 1092 2508 1113 2622 1133 2735 1153 2849 1174 2962 1194 3076 NOTE: L-Drive left of bold line.05 1.110 [0.13 0.93 0.52] 2.023] [0.00 1.50] DNA 0.1 [.— — — — — 1361 1443 1526 1609 1692 1774 1857 1940 2023 2105 2188 2271 — — — — — 672 686 699 713 726 740 753 767 780 794 807 821 673 686 700 713 727 740 754 767 781 794 808 821 835 848 1270 1352 1435 1518 1601 1683 1766 1849 1932 2014 2097 2180 2263 2345 700 714 727 741 754 768 781 795 808 822 835 840 862 876 1344 1427 1510 1592 1675 1758 1841 1923 2006 2089 2172 2254 2337 2420 728 741 755 768 782 795 809 822 836 849 863 876 906 914 1419 1501 1584 1667 1750 1832 1915 1998 2081 2163 2248 2329 2462 2581 755 769 782 796 809 823 836 850 853 877 912 919 927 934 1493 1576 1659 1741 1824 1907 1990 2072 2155 2238 2338 2457 2576 2695 1 845 2 810 L 2.08 [0.10 [0.7 [.06 [0.42] 1.20 [0.099 [0. DNA = Data not Available.052] 0.40] 1.071 [0.2 [.15] 0.016] 0.95 0.10 [0.032] 0.05 [0.8 [.11 0.6 [.027] [0.25] 1.97 0.31 [0.027] 4800 [2265] — — — — — — — — — — — — — — DNA DNA 0.067] DNA Standard Indoor Airflow—CFM [L/s] 3600 3800 4000 4200 4400 [1699] [1793] [1888] [1982] [2076] Resistance—Inches Water [kPa] 0.025] 0.16 [0.044] DNA 0.00 4000 [1888] 1.060] DNA 0. Do not operate above blower RPM shown as motor overloading will occur.13 [0. 3200 [1510] ACTUAL—CFM [L/s] 1.32] 1.0 [.99 3600 [1699] 0. 3200 [1510] 3300 [1557] 3400 [1605] 3500 [1652] 3600 [1699] 3700 [1746] 3800 [1793] 3900 [1841] 4000 [1888] 4100 [1935] 4200 [1982] 4300 [2029] 4400 [2077] 4500 [2124] 4600 [2171] 4700 [2218] 4800 [2265] Capacity 10 Ton [35.2 [.040] DNA 0.040] 0.™ 27 .6 [. Do not set motor sheave below one turn open.21 [0.018] 0.019] [0.A.087 0.99 3800 [1793] 1. 3.37 [0.2 kW] Indoor Airflow Performance RLNL-B Series Rely on Ruud.2 [.10] 0.4 [.0 [1491.03 1.035] 0. Resulting sensible capacity cannot exceed total capacity.082 0.07 1.21 [0.080] 0.55] 2.18 [0.042] DNA DNA DNA 0.57] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W AIRFLOW PERFORMANCE—10 TON [35.97 0.042] 0.27] 1.06 0.45] 1.96 0.022] 0.98 3400 [1605] 0. Concentric Diffuser RXRN-FA65 or FA75 & Transition RXMC-CD04 Concentric Diffuser RXRN-AA61 or AA71 & Transition RXMC-CE05 Concentric Diffuser RXRN-AA66 or AA76 & Transition RXMC-CF06 Economizer 100% R.P.18 [0.01 1832 1951 2070 2189 2307 2426 2545 2663 2782 2901 3020 3138 3257 3376 978 986 993 1001 1008 1016 1024 1031 1039 1046 1054 1061 1069 1076 1946 2065 2183 2302 2421 2539 2658 2777 2896 3014 3133 3252 3371 3489 M 3.020] 0.014] 0.24 [0.S.17 [0.99 0.015] [0.9 [.30] 1.09 [0.31 [0.5 [.12] 0.98 TOTAL MBH SENSIBLE MBH POWER kW 0.37] 1.01 4600 [2171] NOTES: 1.022] [0.27 [0. Damper Open Wet Coil Component 3200 [1510] DNA 0.012] 0.1 [.0.47] 2.19 [0.00 1.A.09 [0.20] 0. Factory sheave settings are shown in bold print.02 1.3 [.052] DNA 0.0 [2237. Drive Package Motor H.077] 0. Damper Open Horizontal Economizer 100% R.065 [0.7 [.045] 0.14 [0.09 [0.32 [0.022] 0.35] 1. [W] Blower Sheave Motor Sheave Turns Open RPM 783 796 810 823 837 850 864 877 917 924 932 940 947 955 1.12 [0.077] 3400 [1604] DNA 0.09 1.5 [.027] DNA 0.025] NOTE: Add component resistance to duct resistance to determine total external static pressure.36] [0.11 [0.98 0.02 1.030] [0.076 0.3 [.12 0.092] DNA 0.017] [0.4] BK90 1VP-44 3 4 775 739 810 824 837 861 864 878 922 930 937 945 952 960 967 975 5 704 1588 1650 1733 1818 1899 1961 2064 2147 2215 2333 2452 2571 2689 2808 838 851 865 878 927 935 942 950 957 965 973 980 988 995 6 669 1642 1725 1808 1890 1973 2056 2091 2209 2328 2447 2585 2684 2803 2922 865 879 933 940 948 955 963 970 978 985 993 1000 1008 1015 1 1138 1717 1799 1882 1965 2015 2085 2204 2323 2442 2560 2679 2798 2916 3035 0.01 4400 [2077] AIRFLOW CORRECTION FACTORS 10 TON [35.07 0.1] BK65 1VP-44 3 4 1041 992 958 966 973 981 988 996 1003 1011 1018 1026 1033 1041 1048 1056 975 989 1002 1016 1029 1043 1056 1070 1083 1097 1110 1124 1137 1151 5 943 2059 2178 2297 2416 2534 2653 2772 2890 3009 3128 3247 3365 3484 3603 1003 1016 1030 1043 1057 1070 1084 1097 1111 1124 1138 1151 1165 1178 6 894 2173 2292 2410 2529 2648 2767 2885 3004 3123 3241 3360 3479 3598 3716 1039 1047 1054 1062 1069 1077 1084 1092 1099 1107 1115 1122 1130 1137 2286 2405 2524 2643 2761 2880 2999 3117 3236 3355 3474 3592 3711 3830 1059 1067 1075 1082 1090 1097 1105 1112 1120 1127 1135 1142 1150 1157 2400 2519 2637 2756 2875 2994 3112 3231 3350 3468 3587 3706 3825 3943 1080 1087 1095 1102 1110 1117 1125 1133 1140 1148 1155 1163 1170 1178 2513 2632 2751 2870 2988 3107 3226 3345 3453 3582 3701 3819 3938 4057 1100 1108 1115 1123 1130 1138 1145 1153 1160 1168 1175 1183 1190 1198 2627 2746 2864 2983 3102 3221 3339 3458 3577 3695 3814 3933 4052 4170 1120 1128 1135 1143 1150 1158 1166 1173 1181 1188 1196 — — — 2740 2859 2978 3097 3215 3334 3453 3572 3690 3809 3928 — — — 1141 1148 1156 1163 1171 1178 1186 1193 — — — — — — 2854 2973 3091 3210 3329 3448 3566 3685 — — — — — — 1161 1168 1176 1183 1191 1199 — — — — — — — — 2968 3086 3205 3324 3442 3561 — — — — — — — — 1181 1189 1196 — — — — — — — — — — — 3081 3200 3318 — — — — — — — — — — — — — — — — — — — — — — — — — 0.026] 4600 [2171] COMPONENT AIR RESISTANCE. 05] 0.7 [.03] 0.16 0.02 [ ] Designates Metric Conversions NOTES: 1.03] 0.25 0.36 0.1] BK72H 1VP-44 3 4 966 920 854 880 908 936 964 993 1023 1053 1084 1115 1147 879 905 932 960 988 1017 1046 1076 1106 1137 1169 5 876 1661 1859 2079 2319 2581 2864 3168 3494 3841 4209 4598 904 930 957 984 1012 1040 1069 1098 1128 1159 1190 6 824 1722 1927 2153 2400 2669 2959 3270 3603 3956 4331 4728 929 955 981 1008 1035 1063 1091 1120 1150 1180 1211 1 1294 1786 1997 2230 2485 2760 3057 3375 3715 4076 4458 4861 954 979 1005 1031 1058 1086 1114 1142 1171 1201 1232 2 1256 1853 2072 2312 2573 2855 3159 3484 3831 4198 4587 4997 979 1004 1029 1055 1081 1108 1136 1164 1193 1222 1252 1998 2230 2484 2759 3056 3373 3712 4072 4454 4857 5281 1004 1028 1053 1078 1104 1131 1158 1186 1214 1243 1272 M 5.08 0.40] 1.02] [.09 0.96 1.43 [.15] 0.03 1.07 1. Do not set motor sheave below minimum or maximum turns open shown.13 [.21 0.08 0.25 1.33 0.03] [. Drive data shown is for horizontal airflow with dry coil.0 kW] NOTES: 1.24 0. SENSIBLE MBH 0.09 0.11 0.02 1.10 0.02] [.0 [.32 0. IWC 12.09] [.19 0.04] [.28 1.00 1.44 [.02] [.22] 1.05] 0.05] [.02] [.04] [.18 0.02] [. Multiply correction factor times gross performance data.04 1.05] Horizontal Economizer 0.12 0.10 0.11] 5400 5600 5800 [2548] [2643] [2737] 2714 3002 3312 3642 3994 4367 — — — — — Standard Indoor Airflow—CFM [L/s] 3800 4000 4200 4400 4600 4800 5000 5200 Component [1793] [1888] [1982] [2076] [2171] [2265] [2359] [2454] Resistance—Inches Water [kPa] 0.01 1.07 6 1094 2156 2403 2670 2959 3270 3601 3954 4328 4723 5140 5578 COMPONENT AIR RESISTANCE.05] 0.13 0.18 1.5] BK85H 1VP-65 3 4 1216 1177 1924 2149 2396 2664 2954 3265 3597 3950 4324 4720 5137 1028 1052 1076 1101 1127 1153 1179 1207 1235 1263 1292 1052 1075 1099 1124 1149 1175 1201 1228 1256 1284 — 1076 1099 1122 1146 1171 1196 1222 1249 1276 — — 2328 2589 2870 3173 3497 3843 4209 4597 5007 — — 1099 1122 1145 1169 1193 1218 1244 1270 1296 — — 2420 2687 2975 3285 3616 3969 4342 4737 5153 — — 1123 1145 1168 1191 1215 1239 1264 1290 — — — 2514 2789 3084 3401 3739 4098 4479 4880 — — — 1146 1168 1190 1213 1236 1261 1285 — — — — 2613 2894 3196 3520 3865 4231 4618 — — — — 1169 1190 1212 1235 1258 1282 — — — — — 0.21 [.02] 0.5 TON [44.08 0.52 [.38 [0. 4. — 1735 1941 2167 2415 2684 2975 3286 3619 3974 4349 External Static Pressure—Inches of Water [kPa] 0. Factory sheave settings are shown in bold print.8] [0.15 0.14 1.11 [.0 [.04] [.02] [.00 1. [W] Blower Sheave Motor Sheave Turns Open RPM NOTE: L-Drive left of bold line. 1192 1213 1234 1256 1279 — — — — — — 2819 3114 3430 3768 4127 — — — — — — 1215 1235 1256 1278 1300 — — — — — — 2928 3230 3553 3897 4263 — — — — — — 0. Drive Package Motor H.05 1.08] [.34 0.3 [.50] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W Model RLNL-B151 Voltage 208/230.10] 0.9 [.10 0.8 [. 2.8] 2241 2494 2769 3065 3382 3720 4080 4461 4863 5287 — ACTUAL—CFM 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 [L/s] [1793] [1888] [1982] [2077] [2171] [2265] [2360] [2454] [2549] [2643] [2737] TOTAL MBH 0.5 [. 460.02 1.23 0.13 [.48 [.03] [.11] 0.01 1.99 1.0 kW] 5 1136 2075 2315 2575 2858 3161 3485 3831 4199 4587 4997 5428 AIRFLOW CORRECTION FACTORS 12. Add component resistance (below) to duct resistance to determine total External Static Pressure.03] Concentric Grill RXRN-AA61 or 0.47] 2.03] [.28 Rely on Ruud.05] [.36 RXRN-AA76 & Transition RXMC-CF06 [0.05] 0.12] 0.0 [3728.05] [.14 [.19 RA Damper Open [.25] 1.03] [.30] 1.02] [.4 [.01 1.6 [.04 1.12 Wet Coil [.03] 0.™ 828 855 883 911 940 970 1000 1030 1062 1093 1126 1605 1796 2008 2241 2496 2772 3070 3388 3728 4089 4472 1 1051 2 1009 L 3.02] [.03] [.29 0.21 1.8 [.98 0.07] [.03] Downflow Economizer 0.03 NOTE: Add component resistance to duct resistance to determine total external static pressure.00 1.11 1. M-Drive right of bold line.4 [.5 TON [44.27 0.2 [.1 [.7 [.37] 1. 3.22 [.02] [.07 0.13 [.03] 0.02 1.02] [.07] [.14 0.10 0.07] 0. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum External Static Pressure.30 0.20] 0.03] 0.40 [.40 RXRN-AA71 & Transition RXMC-CE05 [.00 1.10] Concentric Grill RXRN-AA66 or 0.2 [.00 1.0 [2237. 575 — 3 phase 60 Hz 3800 [1793] — — — — — 4000 [1888] — — — — 830 4200 [1982] — — 832 1877 858 4400 [2076] 836 2029 862 2096 886 4600 [2171] 867 2263 891 2337 916 4800 [2265] 897 2518 922 2599 946 5000 [2359] 929 2795 953 2883 976 5200 [2454] 961 3093 984 3188 1007 5400 [2548] 993 3412 1016 3514 1039 5600 [2643] 1026 3752 1049 3861 1071 5800 [2737] 1060 4114 1082 4230 1104 Air Flow CFM [L/s] AIRFLOW PERFORMANCE—12.09 0.7] [0.27] 1.03 1.02] [.03] 0. 2. Resulting sensible capacity cannot exceed total capacity.04] [.6] [0.17 0.12] 0.P.42] 1.35] 1.45] 1.5 TON [44.9] 0.13] 0.07 0.32] 1.17] 0.8] [0.3 [.99 1.7] [0.11 RA Damper Open [.9 [.10] 0.6 [.03 1.02] [.1 [.27 0.5 [.30 0.06 1.6] [0.20 [.0 kW] Indoor Airflow Performance RLNL-B Series .11 0.93 POWER kW 0.12 [.7] [0. 1/13.5 83.9 28. Compressor 1 6 6 6 6 6 6 3 1/4 3 1/4 3 1/4 Amps (RLA).8 14.6 2.7 4.1 83.2 1/3 1. Comp.1/13.7 2.4 1.7 4.1 No.4 1 1 1/3 1.1 13.2 6.2 8.1 83. 1 19.5 4. 2 2 2 2 2 2 2 2 2 Volts 208/230 208/230 460 460 575 575 Phase HP 1 1/3 1 1/3 1 1/3 1 1/3 1 1/3 1 1/3 208/230 1 208/230 1 208/230 1 Amps (FLA.7/4.7/4.2/1.5 Rely on Ruud.4 14.8 2.7/4. 1 1 1 1 1 1 1 1 1 Volts 208/230 208/230 460 460 575 575 208/230 208/230 208/230 3 Phase 3 3 3 3 3 3 3 3 HP 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 2 2 3 Amps (FLA.9 56/56 13/13 Amps (LRA.4 1.6 8.8/28.2 1/3 1.8/28.6 13.6/19.™ 29 .6 19.1/83.4 2.6 5.4 14 14 1.9 56/56 74. each) 2.7 4.6 6.4/2.4 2.4 1. 1 1 1 1 1 1 2 2 2 Volts 200/240 200/240 480 480 600 600 200/240 200/240 200/240 Phase 3 3 3 3 3 3 3 3 3 RPM 3450 3450 3450 3450 3450 3450 3450 3450 3450 HP.1/83. 1 136/136 136/136 66.8 28.8 1.5/74.1/13.4/2. Comp. each) 4.6/19.9 1.1 13.1 Amps (LRA).2/1.5 1. each) 1.7/4.1 66.6/5.2/1.7 No.6/5.2 Amps (LRA.Electrical Data RLNL-B Series Evaporator Fan Condenser Motor Compressor Motor Unit Information ELECTRICAL DATA – RLNL SERIES Unit Operating Voltage Range Volts Minimum Circuit Ampacity Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size B073CL B073CM B073DL B073DM B073YL B073YM B090CL B090CM B090CN 187-253 187-253 414-506 414-506 518-632 518-632 187-253 187-253 187-253 208/230 208/230 460 460 575 575 208/230 208/230 208/230 35/35 35/35 16 16 13 13 43/43 43/43 48/48 40/40 40/40 20 20 15 15 45/45 45/45 50/50 50/50 50/50 20 20 15 15 50/50 50/50 60/60 No. each) 5.1/83.7/4.1 55.3 55. 5 4 28 .1 3 1/4 4. Compressor 2 Amps (FLA.4 1 1 1 1 1 1 1 1 1 460 3 460 3 460 3 575 3 575 3 575 3 208/230 3 208/230 3 460 3 2 2 3 2 2 3 2 3 2 4 28 4 28 7 38.5 0.5 1.Electrical Data RLNL-B Series Evaporator Fan Condenser Motor Compressor Motor Unit Information ELECTRICAL DATA – RLNL SERIES Unit Operating Voltage Range Volts Minimum Circuit Ampacity Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size No. Volts Phase HP Amps (FLA.4 16/16 16/16 7. Compressor 1 Amps (RLA).1 4 19 4 19 8 20 8/8 56/56 13/13 74.4 3 1/4 4.2 4.7 0. Volts Phase HP Amps (FLA.4 0.2 4. each) Amps (LRA) No. each) No.4 3 3/4 16/16 3 3/4 16/16 3 3/4 7.7 2.7/4.4 0.1 3 1/4 6.5/74.1 41 41 41 33 33 33 91/91 91/91 46 2 2 2 2 2 2 2 2 2 460 1 460 1 460 1 575 1 575 1 575 1 208/230 1 208/230 1 460 1 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 0. Comp.5 0.1 4. each) Amps (LRA.5 1.7 2.4 4.5 1. 1 HP. Comp.1 6.2/1.4 3 1/4 4.4 4. 1 Amps (LRA).1 6.1 41 41 41 33 33 33 91/91 91/91 46 3 1/4 6.™ B090DL B090DM B090DN B090YL B090YM B090YN B102CL B102CM B102DL 414-506 414-506 414-506 518-632 518-632 518-632 187-253 187-253 414-506 460 460 460 575 575 575 208/230 208/230 460 21 21 24 16 16 21 49/49 54/54 23 25 25 25 20 20 25 50/50 55/55 25 25 25 30 20 20 25 60/60 60/60 25 2 2 2 2 2 2 2 2 2 480 3 3450 480 3 3450 480 3 3450 600 3 3450 600 3 3450 600 3 3450 200/230 3 3450 200/230 3 3450 460 3 3450 3 1/4 3 1/4 3 1/4 3 1/4 3 1/4 3 1/4 3 3/4 3 3/4 3 3/4 6. each) 30 Rely on Ruud.4 0.7/4.5 1.7 1.7 2.2/1.7 2. Volts Phase RPM HP. each) Amps (LRA.1 3 1/4 6. 5 4 28 7 38.™ 31 . Compressor 1 Amps (RLA). Volts Phase HP Amps (FLA.9 3 3/4 7. each) Amps (LRA.2/1.1 5.5 1. Volts Phase RPM HP. each) No.7 1.8 4 1/4 9.9 2 2 2 2 2 2 2 2 2 460 1 575 1 575 1 208/230 1 208/230 1 460 1 460 1 575 1 575 1 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 0. each) Amps (LRA. Comp.5 0.4 0.7 2. each) B102DM B102YL B102YM B120CL B120CM B120DL B120DM B120YL B120YM 414-506 518-632 518-632 187-253 187-253 414-506 414-506 518-632 518-632 460 575 575 208/230 208/230 460 460 575 575 26 19 24 49/49 54/54 25 28 19 24 30 20 25 50/50 55/55 25 30 20 25 30 20 30 60/60 60/60 30 35 20 30 2 2 2 2 2 2 2 2 2 460 3 3450 575 3 3450 575 3 3450 200/240 3 3450 200/240 3 3450 480 3 3450 480 3 3450 575 3 3450 575 3 3450 3 3/4 3 3/4 3 3/4 4 1/4 4 1/4 4 1/4 4 1/4 4 1/4 4 1/4 7.7/4.9 38.2/1. Comp.1 4 19 8 20 Rely on Ruud.5 1. Compressor 2 Amps (FLA.8 5.7 2.7 0.7 2. each) Amps (LRA) No.6 5.6 4 1/4 16/16 4 1/4 16/16 4 1/4 9.7 46 37 37 110/110 110/110 52 52 38.7 46 37 37 110/110 110/110 52 52 38.1 3 3/4 5.8 9.5 1.7 5.4 0.2 4.7/4.6 16/16 16/16 9. Volts Phase HP Amps (FLA.8 4 1/4 5.1 4 19 8 20 8/8 56/56 13/13 74.7 4 1/4 5. 1 Amps (LRA). 1 HP.4 0.9 38.2 4.5/74.5 1.5 1 1 1 1 1 1 1 1 1 460 3 575 3 575 3 208/230 3 208/230 3 460 3 460 3 575 3 575 3 3 2 3 2 3 2 3 2 3 7 38.5 0.Electrical Data RLNL-B Series Evaporator Fan Condenser Motor Compressor Motor Unit Information ELECTRICAL DATA – RLNL SERIES Unit Operating Voltage Range Volts Minimum Circuit Ampacity Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size No.6 3 3/4 5.5 1. 2 1 1 1 1 1 1 208/230 3 208/230 3 460 3 460 3 575 3 575 3 3 5 3 5 3 5 15/15 74.™ B151CL B151CM B151DL B151DM B151YL B151YM 187-253 187-253 414-506 414-506 518-632 518-632 208/230 208/230 460 460 575 575 67/67 71/71 33 36 28 28 70/70 75/75 35 40 30 30 80/80 90/90 40 45 35 35 2 2 2 2 2 2 208/230 3 3450 208/230 3 3450 460 3 3450 460 3 3450 575 3 3450 575 3 3450 5 3/4 5 3/4 5 3/4 5 3/4 5 3/4 5 3/4 22. 1 Amps (LRA).75 3. Compressor 1 Amps (RLA).6 1/2 1. each) Amps (LRA. Volts Phase HP Amps (FLA.5 18.7 7.2 1/2 0.3 8 20 8 33 .4 10.8/18.7 75 5 1/4 9.6/5.15/1.5 2.15 5.6 1/2 0.4 22. each) 32 Rely on Ruud.6 7 38. Volts Phase HP Amps (FLA. Volts Phase RPM HP.4 54 5 1/4 7.Electrical Data RLNL-B Series Evaporator Fan Condenser Motor Compressor Motor Unit Information ELECTRICAL DATA – RLNL SERIES Unit Operating Voltage Range Volts Minimum Circuit Ampacity Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size No. Comp. Comp.6 7.6/5.4/22.5 2.1 1/2 0.8 82.7 54 5 1/4 7.4/22. each) No. Compressor 2 Amps (FLA.75 3. each) Amps (LRA) No.4 123/123 123/123 62 62 50 50 2 2 2 2 2 2 208/230 1 208/230 1 460 1 460 1 575 1 575 1 1/2 1.5/74.15/1.1 1/2 0.15 5. each) Amps (LRA.6/82.1 10 41. 1 HP.6 10.7 149/149 5 1/4 19/19 149/149 5 1/4 19/19 75 5 1/4 9. 6 40/46.16/163.13/65.8/14.13/65.2/9.25/131 — 24. @ 208 V 40/50 45/50 45/50 60/60 90/90 45/50 50/50 50/50 60/60 90/90 125/125 50/60 60/60 60/60 60/60 90/90 125/125 50/60 60/60 60/60 60/60 90/90 125/125 150/150 70/80 80/80 80/80 80/80 100/100 125/125 150/150 Min.25 98.4 14.4 100.5 Heater Amp.13 49.56/32.84/49.75 36.4 — 20/23.25/131 123.69/98.8/38.1/92.56/32.8/38.™ 33 ./Max.8/14.8 28.56/32.69/98. + = Field installed only.8 28.69/98.25/131 — 24./Max.6 10.4 14. Ckt.2 21.3 80. Circuit Ampacity 208/240 V Min.1/48 No.3 80.1 30/34.8 — 7.2 21.25 98.25 98.2/9.25 — 24.1 30/34.84/49.6 10. of Sequence Steps — 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 1 — 1 1 1 1 1 1 RXJJHeater Kit Nominal kW No Heat CC10C CC15C CC20C CC30C No Heat CC10C CC15C CC20C CC30C CC40C No Heat CC10C CC15C CC20C CC30C CC40C No Heat CC10C CC15C CC20C CC30C CC40C CC50C No Heat CC10C CC15C CC20C CC30C CC40C CC50C *= For Canadian use only.6/28.1 30/34.2 60/69.6 10.6 40/46.13 49.13 49.8/38.4 14.8/14.75 36.84/49.3 80.4 36.2 60/69.4 — 20/23.2 21.4/19.6/28.1/92. @ 208 V 40/50 — — — — 45/50 — — — — — 50/60 — — — — — 50/60 — — — — — — 70/80 — — — — — — Min. Uses “P” fuses for inductive circuit.84/49. Ampacity 208/240 V — 25/30 40/45 50/60 80/90 — 25/30 40/45 50/60 80/90 110/125 — 25/30 40/45 50/60 80/90 110/125 — 25/30 40/45 50/60 80/90 110/125 150/150 — 25/30 40/45 50/60 80/90 110/125 150/150 Max. AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Electric Heater Kits RLNL-B Series Rely on Ruud.16/163.6 40/46.8 28.2 21.13 49. THREE PHASE. B151CL B120CL B102CL B090CL B073CL Unit Model No.1 30/34.5 — 20/23.56/32.1/115.4 — 7.4/19. @ 240 V 40/50 — — — — 45/50 — — — — — 50/60 — — — — — 50/60 — — — — — — 70/80 — — — — — — Over Current Protective Device Size Air Conditioner Separate Power Supply For Both Unit and Heater Kit 208/240 VOLT.4/19. @ 240 V 40/50 45/50 60/60 70/70 100/100 45/50 50/50 60/60 70/70 100/100 150/150 50/60 60/60 60/60 70/70 100/100 150/150 50/60 60/60 60/60 70/70 100/100 150/150 175/175 70/80 80/80 80/80 80/80 110/110 150/150 175/175 Over Current Protective Device Size Air Conditioner — 25/29 38/44 50/58 75/87 — 25/29 38/44 50/58 75/87 101/116 — 25/29 38/44 50/58 75/87 101/116 — 25/29 38/44 50/58 75/87 101/116 126/145 — 25/29 38/44 50/58 75/87 101/116 126/145 Min.4 100.13 49.5 73.3 80.25/131 123./Max.1/92.2 60/69.6 40/46.1 30/34.2/9. Fuse Size 208/240 V Heater Kit 35/35 — — — — 43/43 — — — — — 49/49 — — — — — 49/49 — — — — — — 67/67 — — — — — — Min.6/28.2/9.75 36. Ampacity @ 208/240 V Single Power Supply For Both Unit and Heater Kit Min.8/14.75 Heater KBTU/Hr @ 208/240 V — 20/23.56/32. @ 208/240 V 35/35 35/36 45/51 57/65 82/94 43/43 43/43 48/54 60/68 85/97 111/126 49/49 49/49 49/54 60/68 85/97 111/126 49/49 49/49 49/54 60/68 85/97 111/126 136/155 67/67 67/67 67/67 69/77 94/106 119/135 144/164 Unit Min.69/98.8/14./Max.75 36.13/65. RLNL- Heater Kit — 24. Ckt.5 73.6/28.2/9.69/98.2 60/69.6 40/46.2 60/69.1/48 — 7.3 — 20/23.84/49.4 — 7.75 — 24.4 36.5 73.75 36.6/28.2 21. 60 HZ.4/19.6 10.1/115.1/92.8 28.5 73.13/65.5 73.13/65.8/38.Rated Heater kW @ 208/240 V — 7.4 14.4/19.4 14.25 98.6 10. 4 — 7.1/92.56/32.56/32.6 40/46.6/28.75 36.8/38.4 100.8/38.2 60/69.6 10.5 Heater Amp.8/38.6 40/46.56/32.8 28.69/98.6 40/46.1/92. Ckt.8/14.4 14.25/131 123.13 49.2 60/69. 60 HZ. Ampacity 208/240 V — 25/30 40/45 50/60 80/90 — 25/30 40/45 50/60 80/90 110/125 — 25/30 40/45 50/60 80/90 110/125 — 25/30 40/45 50/60 80/90 110/125 150/150 — 25/30 40/45 50/60 80/90 110/125 150/150 Max.3 — 20/23.5 73.2/9.2 21.2 21.16/163.8 28.1/92.™ Rated Heater kW @ 208/240 V — 7. of Sequence Steps — 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 1 — 1 1 1 1 1 1 RXJJHeater Kit Nominal kW No Heat CC10C CC15C CC20C CC30C No Heat CC10C CC15C CC20C CC30C CC40C No Heat CC10C CC15C CC20C CC30C CC40C No Heat CC10C CC15C CC20C CC30C CC40C CC50C No Heat CC10C CC15C CC20C CC30C CC40C CC50C Heater Kit *= For Canadian use only.4 36.4/19.3 80.1 30/34.1 30/34.1 30/34. @ 208/240 V 35/35 35/36 45/51 57/65 82/94 43/43 43/43 48/54 60/68 85/97 111/126 54/54 54/54 54/60 67/75 92/103 117/132 54/54 54/54 54/60 67/75 92/103 117/132 142/161 71/71 71/71 71/71 74/82 99/111 124/140 149/168 Unit Min.4 — 7.13 49. Ampacity @ 208/240 V Single Power Supply For Both Unit and Heater Kit Min. @ 240 V 40/50 — — — — 45/50 — — — — — 55/60 — — — — — 55/60 — — — — — — 75/90 — — — — — — Over Current Protective Device Size Air Conditioner Separate Power Supply For Both Unit and Heater Kit 208/240 VOLT.2/9.69/98. Uses “P” fuses for inductive circuit.84/49.8/14.2/9. AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Electric Heater Kits RLNL-B Series ./Max.6/28. @ 208 V 40/50 45/50 45/50 60/60 90/90 45/50 50/50 50/50 60/60 90/90 125/125 55/60 60/60 60/60 70/70 100/100 125/125 55/60 60/60 60/60 70/70 100/100 125/125 150/150 75/90 80/90 80/90 80/90 100/100 125/125 150/150 Min.6/28.56/32.4 14.2 21.75 36.6 10.75 — 24.13/65.75 Heater KBTU/Hr @ 208/240 V — 20/23. + = Field installed only. Fuse Size 208/240 V Heater Kit 35/35 — — — — 43/43 — — — — — 54/54 — — — — — 54/54 — — — — — — 71/71 — — — — — — Min.13/65.13 49.4 14.16/163.2 60/69.84/49.13/65.25/131 — 24.2/9.4/19.4 — 20/23.75 36.4 100.25/131 123.8 28.84/49.13/65.84/49.4 36.75 36. @ 240 V 40/50 45/50 60/60 70/70 100/100 45/50 50/50 60/60 70/70 100/100 150/150 55/60 60/60 60/60 80/80 110/110 150/150 55/60 60/60 60/60 80/80 110/110 150/150 175/175 75/90 80/90 80/90 90/90 125/125 150/150 175/175 Over Current Protective Device Size Air Conditioner — 25/29 38/44 50/58 75/87 — 25/29 38/44 50/58 75/87 101/116 — 25/29 38/44 50/58 75/87 101/116 — 25/29 38/44 50/58 75/87 101/116 126/145 — 25/29 38/44 50/58 75/87 101/116 126/145 Min.4/19.5 73.8/14.4/19.2/9.1/48 — 7. B151CM B120CM B102CM B090CM B073CM Unit Model No.1/48 No.25 98.8 28.8/38.4 — 20/23.69/98. RLNL— 24.8 — 7.3 80.2 60/69.13/65.6 10.1/115.3 80. Ckt.25 — 24./Max.56/32.75 36.3 80.2 60/69.69/98.5 73. @ 208 V 40/50 — — — — 45/50 — — — — — 55/60 — — — — — 55/60 — — — — — — 75/90 — — — — — — Min.84/49. THREE PHASE.6 40/46.25 98.6/28.25/131 — 24./Max.4 14.5 73.1/92.8/14.6 10.2 21.8/14.4/19.5 — 20/23.69/98.13 49.34 Rely on Ruud. Circuit Ampacity 208/240 V Min.1 30/34.1/115.5 73.13 49./Max.1 30/34.25 98.4 14.6/28.6 10.6 40/46.2 21.25 98. Ampacity 480 V — 15 25 30 45 — 15 25 30 45 60 — 15 25 30 45 60 — 15 25 30 45 60 80 — 15 25 30 45 60 80 Max.4 19.75 49. + = Field installed only. @ 480 V 16 18 26 33 47 21 21 27 34 49 63 23 23 27 34 49 63 25 25 27 34 49 63 78 33 33 33 38 52 67 81 Unit Min.75 49.6 14.5 98. @ 480 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Over Current Protective Device Size Air Conditioner — 15 22 29 44 — 15 22 29 44 58 — 15 22 29 44 58 — 15 22 29 44 58 73 — 15 22 29 44 58 73 Min.13 65.25 131 — 32. Ckt.1 34.13 65. Uses “P” fuses for inductive circuit.6 — 11./Max.5 17.5 17.1 34./Max.4 48 No.8 38.2 28./Max.5 98.75 49. B151DL B120DL B102DL B090DL B073DL Unit Model No. @ 480 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Over Current Protective Device Size Air Conditioner Separate Power Supply For Both Unit and Heater Kit 480 VOLT.6 14. @ 480 V 20/20 20/20 30/30 35/35 50/50 25/25 25/25 30/30 35/35 50/50 70/70 25/25 25/25 30/30 35/35 50/50 70/70 25/30 30/30 30/30 35/35 50/50 70/70 80/80 35/40 40/40 40/40 40/40 60/60 70/70 90/90 Min.25 131 — 32.2 28.3 23.2 57.7 Heater Amp.5 17.6 46.13 65.4 48 — 9.Rated Heater kW @ 480 V — 9.8 38.75 49. @ 480 V 20/20 — — — — 25/25 — — — — — 25/25 — — — — — 25/30 — — — — — — 35/40 — — — — — — Min.3 23.5 17.8 — 9.6 46.1 34.5 98.4 19.4 — 9.75 49.6 14.8 38.13 65.4 19. of Sequence Steps — 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 1 — 1 1 1 1 1 1 RXJJHeater Kit Nominal kW No Heat CC10D CC15D CC20D CC30D No Heat CC10D CC15D CC20D CC30D CC40D No Heat CC10D CC15D CC20D CC30D CC40D No Heat CC10D CC15D CC20D CC30D CC40D CC50D No Heat CC10D CC15D CC20D CC30D CC40D CC50D *= For Canadian use only.1 34.4 — 9.6 14.1 34. Fuse Size 480 V Heater Kit 16 — — — — 21 — — — — — 23 — — — — — 25 — — — — — — 33 — — — — — — Min. Ckt. AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Electric Heater Kits RLNL-B Series Rely on Ruud.25 131 163.75 Heater KBTU/Hr @ 480 V — 11.7 — 11. RLNL- Heater Kit — 32. 60 HZ.™ 35 .2 — 11.13 65.8 38.75 — 32.2 — 11.2 28.4 19.6 46. THREE PHASE.6 14.5 98.2 28.2 57.5 17.3 23.2 28.6 46. Circuit Ampacity 480 V Min.25 131 163. Ampacity @ 480 V Single Power Supply For Both Unit and Heater Kit Min.3 23.3 23./Max.5 98.25 — 32.4 19. 13 65.75 — 32.2 28.5 17.6 14.2 28.13 65. 60 HZ.25 131 — 32.1 34.3 23. @ 480 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Over Current Protective Device Size Air Conditioner — 15 22 29 44 — 15 22 29 44 58 — 15 22 29 44 58 — 15 22 29 44 58 73 — 15 22 29 44 58 73 Min.4 19.6 14. + = Field installed only.6 — 11.8 38.25 — 32.4 48 No.™ Rated Heater kW @ 480 V — 9.5 98. Fuse Size 480 V Heater Kit 16 — — — — 21 — — — — — 26 — — — — — 28 — — — — — — 36 — — — — — — Min.7 — 11.2 28.5 17. Ampacity 480 V — 15 25 30 45 — 15 25 30 45 60 — 15 25 30 45 60 — 15 25 30 45 60 80 — 15 25 30 45 60 80 Max./Max.5 98.4 19. Ampacity @ 480 V Single Power Supply For Both Unit and Heater Kit Min.2 57.3 23.75 Heater KBTU/Hr @ 480 V — 11.25 131 163.75 49.5 98.4 19. @ 480 V 20/20 — — — — 25/25 — — — — — 30/30 — — — — — 30/35 — — — — — — 40/45 — — — — — — Min.5 17.13 65.4 19. RLNL— 32.8 38./Max.2 28. @ 480 V 16 18 26 33 47 21 21 27 34 49 63 26 26 31 38 52 67 28 28 31 38 52 67 81 36 36 36 42 56 71 85 Unit Min. THREE PHASE.4 — 9. B151DM B120DM B102DM B090DM B073DM Unit Model No. Ckt.6 46.5 17./Max.1 34. @ 480 V 20/20 20/20 30/30 35/35 50/50 25/25 25/25 30/30 35/35 50/50 70/70 30/30 30/30 35/35 40/40 60/60 70/70 30/35 30/35 35/35 40/40 60/60 70/70 90/90 40/45 40/45 40/45 45/45 60/60 80/80 90/90 Min.5 17.6 14.6 14. Circuit Ampacity 480 V Min./Max. of Sequence Steps — 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 1 — 1 1 1 1 1 1 RXJJHeater Kit Nominal kW No Heat CC10D CC15D CC20D CC30D No Heat CC10D CC15D CC20D CC30D CC40D No Heat CC10D CC15D CC20D CC30D CC40D No Heat CC10D CC15D CC20D CC30D CC40D CC50D No Heat CC10D CC15D CC20D CC30D CC40D CC50D Heater Kit *= For Canadian use only.2 — 11.5 98.6 46.2 — 11.8 38.75 49.13 65.6 46.75 49.6 14.4 48 — 9.7 Heater Amp.5 98. Ckt. @ 480 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Over Current Protective Device Size Air Conditioner Separate Power Supply For Both Unit and Heater Kit 480 VOLT.2 28.36 Rely on Ruud.2 57. AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Electric Heater Kits RLNL-B Series .1 34.1 34.75 49.4 19.6 46.25 131 — 32.8 — 9.4 — 9.3 23.25 131 163.3 23.13 65.1 34.8 38.3 23. Uses “P” fuses for inductive circuit.75 49. 2 28.25 131 163.25 131 — 32.9 18. @ 600 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Over Current Protective Device Size Air Conditioner Separate Power Supply For Both Unit and Heater Kit 600 VOLT.4 — 9.8 38.5 27.2 Heater Amp.5 27./Max. RLNL- Heater Kit — 32.2 13.75 49. + = Field installed only.6 14.13 65.25 131 — 32.7 — 9.8 38.5 27.4 19.2 28.75 49. Circuit Ampacity 600 V Min. @ 600 V 15/15 20/20 20/20 30/30 40/40 20/20 20/20 25/25 30/30 40/40 60/60 20/20 20/20 25/25 30/30 40/40 60/60 20/20 25/25 25/25 30/30 40/40 60/60 30/35 30/35 30/35 35/35 45/45 60/60 70/70 Min.4 — 9.5 27.75 49. Uses “P” fuses for inductive circuit. Ckt. @ 600 V 13 14 20 26 38 16 17 23 29 40 52 19 19 23 29 40 52 19 19 23 29 40 52 28 28 28 34 45 57 68 Unit Min.5 27. Ampacity 600 V — 15 20 25 35 — 15 20 25 35 50 — 15 20 25 35 50 — 15 20 25 35 50 — 15 20 25 35 50 60 Max. AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Electric Heater Kits RLNL-B Series Rely on Ruud./Max.5 98.13 65.4 48 No. @ 600 V 15/15 — — — — 20/20 — — — — — 20/20 — — — — — 20/20 — — — — — 30/35 — — — — — — Min.2 13. THREE PHASE./Max.9 18. of Sequence Steps — 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 1 RXJJHeater Kit Nominal kW No Heat CC10Y CC15Y CC20Y CC30Y No Heat CC10Y CC15Y CC20Y CC30Y CC40Y No Heat CC10Y CC15Y CC20Y CC30Y CC40Y No Heat CC10Y CC15Y CC20Y CC30Y CC40Y No Heat CC10Y CC15Y CC20Y CC30Y CC40Y CC50Y *= For Canadian use only.25 — 32.7 37 — 9.2 13.Rated Heater kW @ 600 V — 9. @ 600 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Over Current Protective Device Size Air Conditioner — 12 18 24 35 — 12 18 24 35 47 — 12 18 24 35 47 — 12 18 24 35 47 — 12 18 24 35 47 58 Min.4 19. 60 HZ.8 38.9 18. Ampacity @ 600 V Single Power Supply For Both Unit and Heater Kit Min.5 98.25 131 — 32.2 13.2 28.75 49.6 14.8 38.8 — 9.7 37 — 9.5 98.6 14.2 28.4 19.2 13.75 Heater KBTU/Hr @ 600 V — 9.4 19.75 49.4 — 9.2 28.™ 37 .9 18.13 65.9 18.5 98.13 65.7 37 — 9.4 19./Max.5 98.13 65. Fuse Size 600 V Heater Kit 13 — — — — 16 — — — — — 19 — — — — — 19 — — — — — 28 — — — — — — Min.7 37 46.6 14. Ckt.6 14. B151YL B120YL B102YL B090YL B073YL Unit Model No. 75 49.2 28. @ 600 V 15/15 — — — — 20/20 — — — — — 25/30 — — — — — 25/30 — — — — — — 30/35 — — — — — — Min.7 37 — 9.7 — 9.7 37 — 9.75 49.4 19.2 28.5 98.4 19.9 18.25 131 163.7 37 46.75 49.5 27.75 49.9 18. B151YM B120YM B102YM B090YM B073YM Unit Model No./Max./Max.9 18. Ckt.2 13.4 19.9 18.5 98.5 27. RLNL— 32.8 38.2 28.8 38.5 98.38 Rely on Ruud.4 48 — 9.6 14. @ 600 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Over Current Protective Device Size Air Conditioner Separate Power Supply For Both Unit and Heater Kit 600 VOLT.5 98.2 Heater Amp.4 — 9.8 — 9.75 Heater KBTU/Hr @ 600 V — 9. Ampacity 600 V — 15 20 25 35 — 15 20 25 35 50 — 15 20 25 35 50 — 15 20 25 35 50 60 — 15 20 25 35 50 60 Max.6 14.4 — 9.6 14. @ 600 V 15/15 20/20 20/20 30/30 40/40 20/20 20/20 25/25 30/30 40/40 60/60 25/30 30/30 30/30 35/35 45/45 60/60 25/30 30/30 30/30 35/35 45/45 60/60 70/70 30/35 30/35 30/35 35/35 45/45 60/60 70/70 Min.25 — 32.4 19.2 13. Circuit Ampacity 600 V Min.75 49. THREE PHASE.6 14.2 13./Max. Fuse Size 600 V Heater Kit 13 — — — — 16 — — — — — 24 — — — — — 24 — — — — — — 28 — — — — — — Min.2 13.25 131 163.8 38./Max. AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Electric Heater Kits RLNL-B Series .7 37 46. + = Field installed only.2 28. @ 600 V 13 14 20 26 38 16 17 23 29 40 52 24 24 28 34 45 57 24 24 28 34 45 57 68 28 28 28 34 45 57 68 Unit Min. of Sequence Steps — 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 — 1 1 1 1 1 1 — 1 1 1 1 1 1 RXJJHeater Kit Nominal kW No Heat CC10Y CC15Y CC20Y CC30Y No Heat CC10Y CC15Y CC20Y CC30Y CC40Y No Heat CC10Y CC15Y CC20Y CC30Y CC40Y No Heat CC10Y CC15Y CC20Y CC30Y CC40Y CC50Y No Heat CC10Y CC15Y CC20Y CC30Y CC40Y CC50Y Heater Kit *= For Canadian use only.5 98.9 18. Ampacity @ 600 V Single Power Supply For Both Unit and Heater Kit Min.4 48 No.25 131 — 32.5 27.13 65. 60 HZ.8 38.2 — 9.25 131 — 32.13 65.5 27.2 13.2 28.13 65.4 19.6 14.75 — 32. Ckt.™ Rated Heater kW @ 600 V — 9. Uses “P” fuses for inductive circuit. @ 600 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Over Current Protective Device Size Air Conditioner — 12 18 24 35 — 12 18 24 35 47 — 12 18 24 35 47 — 12 18 24 35 47 58 — 12 18 24 35 47 58 Min.13 65.13 65.5 27. Dimensional Data RLNL-B Series PACKAGE AIR CONDITIONER Illustration ST-A0715-03-X1 BOTTOM VIEW [ ] Designates Metric Conversions Illustration ST-A0734-03 Rely on Ruud.™ 39 . ™ .Dimensional Data RLNL-B Series PACKAGE AIR CONDITIONER SUPPLY AND RETURN DIMENSIONS FOR HORIZONTAL APPLICATIONS Illustration ST-A0736-02-X1 *RECOMMENDED DUCT DIMENSIONS ARE 26" SUPPLY AND RETURN DIMENSIONS FOR DOWNFLOW APPLICATIONS Illustration ST-A0738-02 [ ] Designates Metric Conversions 40 Rely on Ruud. Dimensional Data RLNL-B Series PACKAGE AIR CONDITIONER [ ] Designates Metric Conversions Rely on Ruud.™ 41 . 1-44.05] 21 [9. Recommended Clearance In.60] 135 [61.5 [21.™ .53] 38 [17.50] Operating—lbs [kg] 81 [36. 48" [1219 mm] With Economizer [ ] Designates Metric Conversions 42 Rely on Ruud.82] 140 [63.0] 33% 27% 17% 23% A0 74 40 3 Illustration A074403 CLEARANCES The following minimum clearances must be observed for proper unit performance and serviceability.24] 85 [38.23] Capacity Tons [kW] Corner Weights by Percentage A B C D 6-12.70] 42 [19. [mm] 48 [1219] 18 [457] 18 [457] 18 [457] 60 [1524] Location ABC*D E- Front Condenser Coil Duct Side Evaporator End Above *Without Economizer.82] 44 [19.50] 90 [40.Dimensional Data RLNL-B Series WEIGHTS Accessory Economizer Power Exhaust Fresh Air Damper (Manual) Fresh Air Damper (Motorized) Roof Curb 14" Roof Curb 24" Shipping—lbs [kg] 90 [40.79] 43 [19.96] 26 [11. 3] No Concentric Diffuser (Flush.2] RXRX-CGCC12 450 [204.D.7] RXJJ-CC50 (C. 20" Round) RXRN-FA75 54 [24.0]0 227 [103.5] AXRD-RDCM3 94 [42.3]0 2 [1.2]0 31 [14. 18 x 32) RXRN-AA76 176 [79.Y) 46 [20.5] RXKG-CAE24 140 [63. Model Number RXMC-CD04 ➀ RXMC-CE05 ➁ RXMC-CF06 ➂ RXMD-A04 RXRZ-C02 RXRX-AM01 RXRX-AAD01C ➃ RXRX-AAD02A ➄ RXRX-AN01 Factory Installation Available? No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No No No No No No No No No No [ ] Designates Metric Conversions Rely on Ruud. to Round) Downflow Adapters (Rect.1]0 41 [18.4] RXRX-AR02 3 [1.7] No No No No Yes Yes Yes Yes Yes Accessory Thermostats Electric Heaters*–Canadian Use Only. 18 x 32) Compressor Time-Delay Relay Kit Low-Ambient Control Kit (1 Per Compressor) Freeze-Stat Kit Outdoor Coil Louver Kit Outdoor Coil Louver Kit Unwired Convenience Outlet NOTES: ➀ Used with RXRN-FA65 and RXRN-FA75 concentric diffusers.2] 1 [0. 18 x 28) Downflow Adapters (Rect. 20" Round) Shipping Installed Weight Weight Lbs.2] Concentric Diffuser (Step-Down..0] RXRN-FA65 139 [63.8] 26 [11. to Rect. Economizer w/Single Enthalpy Economizer w/Single Enthalpy and Smoke Dectector Dual Enthalpy Kit Horizontal Economizer w/Single Enthalpy Carbon Dioxide Sensor Power Exhaust Manual Fresh Air (Left Panel Mounted) Manual Fresh Air (Return Panel) Motorized Fresh Air (Return Panel) Motor Kit for RXRF-KDA1 (Left Panel Mounted) Roofcurb.™ 43 .8] RXJJ-CC40 (C.7] RXJJ-CC41 (C.D)* 47 [21.9]0 36 [16.9]0 36 [16.5]0 1 [0.Y) 46 [20.5]0 135 [61.8]0 18 [8.Accessories RLNL-B Series FIELD INSTALLED ACCESSORY EQUIPMENT Concentric Diffuser (Step-Down..0] No Concentric Diffuser (Flush.7]0 185 [83.0]0 60 [27.0] AXRF-JDA1 26 [11.4]0 2 [1.5 [0.2]0 39 [17. 24" Roofcurb Adapters Downflow Adapters (Rect.D.4]0 42 [19. 18 x 28) RXRN-AA71 170 [77.Y) 51 [23.2] AXRF-KDA1 38 [17.D.0] No Concentric Diffuser (Flush.8]0 340 [154. ➂ Used with RXRN-AA66 and RXRN-AA76 concentric diffusers.5] 2 [1.5]0 21 [9.1]0 155 [70. ➃ For 6-10 Ton Models.9] 16 [7.1]0 41 [18.1]0 290 [131. 18 x 32) RXRN-AA66 247 [112.3] 18 [8.Y) 47 [21.2] 26 [11.Y) 46 [20.D)* 90 [40.2] RXRX-CDCE50 300 [136.6]0 89 [40.5] RXRX-AW02 35 [15.5 [0.1]0 2 [1.4]0 1 [0.8]0 85 [38.9]0 36 [16.8]0 21 [9. ➄ For 121/2 Ton Models.3]0 37 [16.0]0 3 [1.0] 0.6] 51 [23.2]0 20 [9.D)* 49 [22.3] RXJJ-CC20 (C. 18 x 28) RXRN-AA61 200 [90.8] RXJJ-CC31 (C.D.3]0 37 [16. ➁ Used with RXRN-AA61 and RXRN-AA71 concentric diffusers.9] RXRX-CFCE56 350 [158.5]0 29 [11.Y) 43 [19.D.3]0 82 [37.4]0 315 [142.9] No Concentric Diffuser (Step-Down. [kg] See Thermostat Specification Sheet for Details (T22-001) RXJJ-CC10 (C.0]0 13 [5.7] RXKG-CAE14 90 [40.2] RXRX-AV02 1 [0.0] No 15 [6.5]0 38 [17.5] RXRX-CFCE54 325 [147.3] RXJJ-CC30 (C.6] RXJJ-CC51 (C.8]0 81 [36.19]0 27 [17.0] RXRX-BFF02 (C.8]0 161 [73.D.2]0 39 [17. 14" Roofcurb. [kg] Lbs.Y) 49 [22. to Rect.3]0 29 [11.8] 1.1]0 410 [186.3] RXJJ-CC15 (C.5] AXRF-JDB1 43 [19.D.7] AXRD-PDCM3 AXRD-SDCM3 91 [41. see specification sheet form number T22-001.™ 500-Series * Communicating/ Programmable . Actual models may vary. For detailed thermostat match-up information. 44 Rely on Ruud.Accessories RLNL-B Series THERMOSTATS 200-Series * Programmable 300-Series * Deluxe Programmable 400-Series * Special Applications/ Programmable * Photos are representative. ™ 45 . Optional Remote Minimum Position Potentiometer (Honeywell #S963B1128) is Available from Prostock.Accessories RLNL-B Series ECONOMIZER FOR DOWNFLOW DUCT INSTALLATION Use to Select Factory Installed Options Only AXRD-PDCM3—Single Enthalpy (Outdoor) and AXRD-SDCM3 Single Enthalpy with Smoke Detector RXRX-AV02—Dual Enthalpy Upgrade Kit RXRX-AR02—Optional Wall-Mounted CO2 Sensor ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Features Honeywell Controls Available Factory Installed or Field Accessory Gear Driven Direct Drive Actuator Fully Modulating (0-100%) Low Leakage Dampers Slip-In Design for Easy Installation Plug-In Polarized 12-pin Electrical Connections Pre-Configured—No Field Adjustments Necessary Standard Barometric Relief Damper Single Enthalpy with Dual Enthalpy Upgrade Kit Available CO2 Input Sensor Available Field Assembled Hood Ships with Economizer Economizer Ships Complete for Downflow Duct Application. Field Installed Power Exhaust Available Prewired for Smoke Detector Illustration ADS-7949-11 [ ] Designates Metric Conversions Rely on Ruud. Accessories RLNL-B Series ECONOMIZER FOR HORIZONTAL DUCT INSTALLATION Field Installed Only AXRD-RDCM3—Single Enthalpy (Outdoor) RXRX-AV02—Dual Enthalpy Upgrade Kit RXRX-AR02—Wall-mounted CO2 Sensor ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Features Honeywell Controls Available as a Field Installed Accessory Only Gear Driven Direct Drive Actuator Fully Modulating (0-100%) Low Leakage Dampers Slip-In Design for Easy Installation Plug-In Polarized 12-pin Electrical Connections Pre-Configured— No Field Adjustments Necessary Standard Barometric Relief Damper Single Enthalpy with Dual Enthalpy Upgrade Kit Available CO2 Input Sensor Available Field Assembled Hood Ships with Economizer Economizer Ships Complete for Horizontal Duct Application Optional Remote Minimum Position Potentiometer (Honeywell #S963B1128) is Available from Prostock Field Installed Power Exhaust Available [ ] Designates Metric Conversions 46 Rely on Ruud.™ . external static pressure.48 0. No.Accessories RLNL-B Series POWER EXHAUST KIT FOR RXRD-PDCM3(-).8 1.5 [ ] Designates Metric Conversions Rely on Ruud.33 0.™ 47 . D.) LRA (ea.75 0.33 NOTES: ➀ Power exhaust is factory set on high speed motor tap.) RXRX-BFF02C RXRX-BFF02D RXRX-BFF02Y 2 2 2 208-230 460 575 1 1 1 0. of Fans Volts Phase HP (ea.) 1. Low Speed CFM [L/s] ➁ 2200 [1038] 2200 [1038] 2200 [1038] RPM 1518 1518 1518 High Speed ➀ RPM CFM [L/s] ➁ 2500 [1179] 1670 2500 [1179] 1670 2500 [1179] 1670 FLA (ea. ➁ CFM is per fan at 0" w. or Y*) *Voltage Code VERTICAL AIRFLOW Illustration STA1000-02 HORIZONTAL AIRFLOW Illustration STA1000-01 Model No.c. RXRD-RDCM3(-).6 1.33 0. RXRD-SDCM3 ECONOMIZERS RXRX-BFF02 (C.81 3. Accessories RLNL-B Series FRESH AIR DAMPER MOTORIZED DAMPER KIT RXRX-AWO2 (Motor Kit for RXRF-KDA1) 79 51 -1 7 a AXRF-KDA1 (Manual) DOWNFLOW OR HORIZONTAL APPLICATION Illustration ST-7951-17 Illustration ST-A0886-38 [ ] Designates Metric Conversions 48 Rely on Ruud.™ . ) AXRF-JDA1 (Manual) AXRF-JDB1 (Motorized) DOWNFLOW APPLICATION Illustration ADS-7937-58 HORIZONTAL APPLICATION Illustration ST-A0901-01 [ ] Designates Metric Conversions Rely on Ruud.Accessories RLNL-B Series FRESH AIR DAMPER (Cont.™ 49 . Roofcurb Model RXKG-CAE14 RXKG-CAE24 TYPICAL INSTALLATION Illustration ST-A0743-02 Height of Curb 14" [356 mm] 24" [610 mm] ROOFCURB INSTALLATION Illustration ST-A0743-02 Illustration ST-A0801-17 [ ] Designates Metric Conversions 50 Rely on Ruud. ■ Opening provided in bottom pan to match the “Thru the Curb” electrical connection opening provided on the unit base pan. ■ Two available heights (14" [356 mm] and 24" [610 mm]) for ALL models. ■ Insulating panels not required because of insulated outdoor base pan.5 ton [21. ■ Packaged for easy field assembly. ■ 1" [25 mm] x 4" [102 mm] Nailer provided.0 kW] RLNL-B models.™ . ■ Quick assembly corners for simple and fast assembly.Accessories RLNL-B Series ROOFCURBS (Full Perimeter) ■ Ruud’s roofcurb design can be utilized on all 6-12.2 m]) provided with Roofcurb. ■ Sealing gasket (40' [12.1-44. A120. A102. (-)RCF-125 RXRK-E56 RXRX-CFCE56 (-)PDC-075 (-)PDC-100/101 RXPK-C12 RXRX-CGCC12 NEW MODELS (All Share Common Cabinet) (R)LNL-B073 (R)LNL-B090 (R)LNL-B102 (R)LNL-B120 (R)LNL-B151 NOTE: Ductwork modifications may be necessary if the capacity and/or indoor airflow rate of replacement unit is not equivalent to that of the unit being replaced. B151 fit on same roofcurb as the RLKB-A090. RLNB. A120. A181. RLNL-B073. RLMB. (-)REG. (-)RCG-100 RXRK-E54 RXRX-CFCE54 (-)RGF.A090. A102. (-)RCF-085 (-)RGF. (-)RGF-131076 (-)RGF-201076 RXRK-E50 RXRX-CDCE50 (-)RGF-200075 (-)RGG. (-)REF.™ 51 . B102. B120. (-)REF. (-)REF. (-)RCF-100 (-)RGG.Accessories RLNL-B Series ROOFCURB ADAPTERS OLD MODELS OLD ROOFCURB ROOFCURB ADAPTER (-)RCF. (-)RCG-075 (-)RGF. B090. A150. A150. A120 Rely on Ruud. (-)REF-075/076 (-)RGF-150075. A102. (-)REG.A090. Accessories RLNL-B Series ROOFCURB ADAPTERS (Cont.™ .) RXRX-CDCE50 Illustration ADS-7952-02 Sheet 2 TOP VIEW Illustration ADS-7952-02 Sheet 1 [ ] Designates Metric Conversions 52 Rely on Ruud. ) RXRX-CFCE54 Illustration ADS-7952-01 Sheet 2 TOP VIEW Illustration ADS-7952-01 Sheet 1 [ ] Designates Metric Conversions Rely on Ruud.™ 53 .Accessories RLNL-B Series ROOFCURB ADAPTERS (Cont. Accessories RLNL-B Series ROOFCURB ADAPTERS (Cont.™ .) RXRX-CFCE56 Illustration ADS-7952-03 Sheet 2 TOP VIEW Illustration ADS-7952-03 Sheet 1 [ ] Designates Metric Conversions 54 Rely on Ruud. ™ 55 .Accessories RLNL-B Series ROOFCURB ADAPTERS (Cont.) RXRX-CGCC12 Illustration ADS-7952-04 Sheet 2 TOP VIEW Illustration ADS-7952-04 Sheet 1 [ ] Designates Metric Conversions Rely on Ruud. Accessories RLNL-B Series CONCENTRIC DIFFUSER APPLICATION Illustration ST-A0840-02 DOWNFLOW TRANSITION DRAWINGS RXMC-CE05 ■ Used with RXRN-AA61 or RXRN-AA71 Concentric Diffusers.™ . Illustration ST-A0881-02 [ ] Designates Metric Conversions 56 Rely on Ruud. ) RXMC-CF06 ■ Used with RXRN-AA66 or RXRN-AA76 Concentric Diffusers. Illustration ST-A0881-03 [ ] Designates Metric Conversions Rely on Ruud.™ 57 .Accessories RLNL-B Series DOWNFLOW TRANSITION DRAWINGS (Cont. ) RXMC-CD04 ■ Used with RXRN-FA65 or RXRN-FA75 Concentric Diffusers.™ 51 03 . 79 Illustration ADS-7951-03 [ ] Designates Metric Conversions 58 Rely on Ruud.Accessories RLNL-B Series DOWNFLOW TRANSITION DRAWINGS (Cont. 5-10.7] 30-37 [9.25 [0.1] 28-35 [8.Accessories RLNL-B Series CONCENTRIC DIFFUSER—STEP DOWN RXRN-FA65 (7.1-11. ➂ Throw is based on diffuser blades being directed in a straight pattern.3] Neck Velocity fpm [m/s] 669 [3. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise.050] 0.™ 59 . Adequate duct attenuation must be provided to reduce sound output from the unit.6-9.092] Throw ➁ ➂ Feet [m] 24-29 [7.5 lbs. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. ■ Built-in anti-sweat gasket. [ ] Designates Metric Conversions Rely on Ruud.7 kg] duct liner.3-8. ■ Built-in hanging supports.4] 720 [3.077] 0.9 kW] Models) For Use With Downflow Transition (RXMC-CD04) and 20" [508 mm] Round Supply and Return Ducts ■ All aluminum diffuser with aluminum return air eggcrate.4 & 29.7] 772 [3.8]0 25-30 [7.4] Noise Level ➃ (dbA) 20 25 25 25 30 NOTES: ➀ All data is based on the air diffusion council guidelines.37 [0.2-10.5 & 8.9] 823 [4. ■ Diffuser box constructed of sheetmetal insulated with 1" [25.2] 874 [4. [. RXRN-FA65 Flow Rate CFM [L/s] 2600 [1227] 2800 [1321] 3000 [1416] 3200 [1510] 3400 [1604] Static Pressure in.042] 0.c.4 mm] 1.1]0 27-33 [8.062] 0. ENGINEERING DATA➀ Model No.17 [0.5 Ton [26. ■ Molded fiberglass supports.20 [0.31 [0. w. [kPa] 0. Accessories RLNL-B Series CONCENTRIC DIFFUSER—STEP DOWN 18" x 28" [457. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. RXRN-AA61 Flow Rate CFM [L/s] 3600 [1699] 3800 [1793] 4000 [1888] 4200 [1982] 4400 [2076] Static Pressure in w. [ ] Designates Metric Conversions 60 Rely on Ruud. ➂ Throw is based on diffuser blades being directed in a straight pattern.2 x 711.4 mm] 1. ■ Diffuser box constructed of sheetmetal insulated with 1" [25. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise. ■ Molded fiberglass supports.2] 34-42 [10. ■ Built-in anti-sweat gasket. ■ Double deflection diffuser with the blades secured by spring steel.2-10.4-12.2 mm] Supply and Return Ducts ■ All aluminum diffuser with aluminum return air eggcrate.045] 0.5 lbs. [kPa] 0.6] 946 [4.6-10.18 [0.21 [0.1] 27-35 [8.2 x 711.3] 898 [4.27 [0.060] 0.™ Neck Velocity fpm [m/s] 851 [4. ■ Built-in hanging supports.7 kg] duct liner.2] Models) For Use With Downflow Transition (RXMC-CE05) and 18" x 28" [457.3] Noise Level ➃ (dbA) 30 30 30 30 30 .17 [0.3] 32-40 [9.8-11.7] 29-37 [8.8-12.8] 993 [5. [.24 [0.c.042] 0.2 mm] RXRN-AA61 (8.067] Throw ➁ ➂ Feet [m] 25-33 [7.0] 1040 [5. Adequate duct attenuation must be provided to reduce sound output from the unit.9 kW & 35.8] NOTES: ➀ All data is based on the air diffusion council guidelines.052] 0. Illustration ADS-7951-08A Illustration ADS-7951-08B Illustration ADS-7951-08C ENGINEERING DATA➀ Model No.5 & 10 Ton [29. ■ Built-in hanging supports. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise. [.7 kg] duct liner.080] 0. ➂ Throw is based on diffuser blades being directed in a straight pattern.5-10.Accessories RLNL-B Series CONCENTRIC DIFFUSER—STEP DOWN 18" x 32" [457.4] 29-35 [8.31 [0.8 kW] Models) For Use With Downflow Transition (RXMC-CF06) and 18" x 32" [457.34 [0.0 & 52. [ ] Designates Metric Conversions Rely on Ruud.5-10. ■ Double deflection diffuser with the blades secured by spring steel.5 & 15 Ton [44.085] 0.2-9. ■ Built-in anti-sweat gasket. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. ■ Molded fiberglass supports.1] 28-34 [8.4 mm] 1.3] 878 [4.39 [0. Adequate duct attenuation must be provided to reduce sound output from the unit.4] 27-32 [8. RXRN-AA66 Flow Rate CFM [L/s] 4600 [2171] 4800 [2265] 5000 [2359] 5200 [2454] 5400 [2548] Static Pressure in w.7] Neck Velocity fpm [m/s] 841 [4.2 x 813 mm] RXRN-AA66 (12.077] 0.0] Noise Level ➃ (dbA) 30 30 30 30 30 NOTES: ➀ All data is based on the air diffusion council guidelines. Illustration ADS-7951-09A Illustration ADS-7951-09B Illustration ADS-7951-09C ENGINEERING DATA➀ Model No.8-10.097] Throw ➁ ➂ Feet [m] 26-31 [7.36 [0.™ 61 .8] 28-33 [8.32 [0.5] 915 [4.6] 951 [4.5 lbs. ■ Diffuser box constructed of sheetmetal insulated with 1" [25.090] 0. [kPa] 0.8] 988 [6.c.2 x 813 mm] Supply and Return Ducts ■ All aluminum diffuser with aluminum return air eggcrate.9-9. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air.31 [0.5 lbs.17 [0.6] 765 [3. w.4-8.4] 714 [3.092] Throw ➁ ➂ Feet [m] 19-24 [5. ■ Molded fiberglass supports.5] 21-29 [6.8-7. Illustration ADS-5348-04 ENGINEERING DATA➀ Model No.5 & 8.042] .™ Neck Velocity fpm [m/s] 663 [3.37 [0.050] .9] 816 [4.7 kg] duct liner.20 [0.4] Noise Level ➃ (dbA) 30 35 35 40 40 .7-9.7-8.8] 22-29 [6.c.077] .Accessories RLNL-B Series FLUSH MOUNT CONCENTRIC DIFFUSER—FLUSH RXRN-FA75 (7.062] . ■ Diffuser box constructed of sheetmetal insulated with 1" [25.8] 22-30 [6. RXRN-FA75 Flow Rate CFM [L/s] 2600 [1227] 2800 [1321] 3000 [1416] 3200 [1510] 3400 [1604] Static Pressure in. ■ Built-in anti-sweat gasket. ■ Built-in hanging supports. [.5 Ton [26.4 mm] 1. [ ] Designates Metric Conversions 62 Rely on Ruud.1] 867 [4. ➂ Throw is based on diffuser blades being directed in a straight pattern.4 & 29.1] NOTES: ➀ All data is based on the air diffusion council guidelines.1-8.3] 20-28 [6. [kPa] .25 [0. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise.9 kW] Models) For Use With Downflow Transition (RXMC-CD04) and 20" [508 mm] Round Supply and Return Ducts ■ All aluminum diffuser with aluminum return air eggcrate. Adequate duct attenuation must be provided to reduce sound output from the unit. 7] 28-37 [8.2 x 711.7-9.2 mm] Supply and Return Ducts ■ All aluminum diffuser with aluminum return air eggcrate.9 & 35.2 x 711.3] 891 [4. Adequate duct attenuation must be provided to reduce sound output from the unit. [ ] Designates Metric Conversions Rely on Ruud.2] Models) For Use With Downflow Transition (RXMC-CE05) and 18" x 28" [457. Illustration ADS-7951-06A Illustration ADS-7951-06B Illustration ADS-7951-06C ENGINEERING DATA➀ Model No.5 & 10 Ton [29. RXRN-AA71 Flow Rate CFM [L/s] 3600 [1699] 3800 [1793] 4000 [1888] 4200 [1982] 4400 [2076] Static Pressure in w.5 lbs.17 [0.24 [0. ➂ Throw is based on diffuser blades being directed in a straight pattern.042] 0.3] Neck Velocity fpm [m/s] 844 [4. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise. [. ■ Built-in hanging supports.Accessories RLNL-B Series CONCENTRIC DIFFUSER—FLUSH and 18" x 28" [457.27 [0.2 mm] RXRN-AA71 (8. ■ Built-in anti-sweat gasket.045] 0.060] 0.8] 985 [5.8] 22-30 [6.™ 63 .18 [0.067] Throw ➁ ➂ Feet [m] 22-29 [6.9-10.7 kg] duct liner.5] 938 [4. ■ Diffuser box constructed of sheetmetal insulated with 1" [25.7-8.5-11. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. ■ Molded fiberglass supports.1] 24-33 [7.052] 0.c. [kPa] 0.2] Noise Level ➃ (dbA) 35 40 40 40 40 NOTES: ➀ All data is based on the air diffusion council guidelines.21 [0.4 mm] 1.1] 26-35 [7.3-10.0] 1032 [5. 6-10.090] 0.085] 0. ➁ Throw data is based on 75 FPM Terminal Velocities using isothermal air. Adequate duct attenuation must be provided to reduce sound output from the unit.5 & 15 Ton [44.39 [0.9-10.31 [0.8 kW] Models) For Use With Downflow Transition (RXMC-CF06) and 18" x 32" [457.c.4] 26-35 [7.™ Throw ➁ ➂ Feet [m] 25-34 [7.9] 1002 [5. ■ Built-in anti-sweat gasket.Accessories RLNL-B Series CONCENTRIC DIFFUSER—FLUSH 18" x 32" [457.1-11.080] 0.2 x 813 mm] Supply and Return Ducts ■ All aluminum diffuser with aluminum return air eggcrate.5] Noise Level ➃ (dbA) 40 40 40 45 45 .077] 0.7] 27-36 [8.9] 32-41 [9.32 [0.5] Neck Velocity fpm [m/s] 922 [4.7] 962 [4.2-11.1] 1043 [5.2 x 813 mm] RXRN-AA76 (12. Illustration ADS-7951-07A Illustration ADS-7951-07B Illustration ADS-7951-07C ENGINEERING DATA➀ Model No.7 kg] duct liner. [ ] Designates Metric Conversions 64 Rely on Ruud. ➂ Throw is based on diffuser blades being directed in a straight pattern. [kPa] 0.4 mm] 1.0] 30-39 [9.34 [0.8-12.5 lbs. [. ■ Built-in hanging supports. ■ Diffuser box constructed of sheetmetal insulated with 1" [25.0 & 52.3] 1083 [5.36 [0. ➃ Actual noise levels may vary due to duct design and do not include transmitted unit noise. RXRN-AA76 Flow Rate CFM [L/s] 4600 [2171] 4800 [2265] 5000 [2359] 5200 [2454] 5400 [2548] Static Pressure in w. ■ Molded fiberglass supports.097] NOTES: ➀ All data is based on the air diffusion council guidelines. Outdoor Fans The outdoor fans shall be direct-drive statically and dynamically balanced. Units shall provide an external location for mounting a fused disconnect device. Evaporator And Condenser Coils Internally finned. fire retardant permanent. Once set. Curb design shall comply with NRCA requirements. The factory-installed economizer arrives ready for operation. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil faced. Filters Two inch [50. throwaway filters shall be standard on all units. Curbs shall be shipped knocked down for toolless field assembly and shall include wood nailer strips. Energy Policy Act of 1992 (EPACT). internally wired. when using an economizer. Unit shall have single point power entry as standard. Operating range for units with electromechanical controls shall be between 125°F (51. to maintain better building pressurization. Units shall have direct-drive. the minimum position setting of economizer shall be adjusted with this accessory. The damper shall close to the full closed position when indoor fan shuts down. fully modulating 0-100 percent motor and dampers. The roof curb design shall allow field-fabricated rectangular supply/return ductwork to be connected directly to the curb. Rely on Ruud. Coils shall be leak tested at the factory to ensure pressure integrity. Canadian units shall be CUL certified. The evaporator coil and condenser coil shall be leak tested to 200 psig and pressure tested to 450 psig. phosphatized. with forklift capabilities on three sides of the unit. Wiring internal to the unit shall be colored and numbered for simplified identification. and finished with a weatherresistant baked enamel finish. mixed air sensor. and single enthalpy control. minimum position setting. wiring harness with plug. Economizer—This accessory shall be either field or factory-installed and is available with barometric relief standard. The compressor shall have external isolation to minimize noise. Cabinet construction shall allow for all maintenance on one side of the unit. classified in accordance to UL 1995/CAN/CSA No. Manual Outside Air Damper—Factory or field-installed rain hood and screen shall provide up to 50 percent outside air.™ 65 . Casing Unit casing shall be constructed of zinc coated. Powered Exhaust—The field installed powered exhaust. it shall not be doublehemmed and gasket-sealed. Units shall be UL listed and labeled. A sloped condensate drain pan shall be standard and shall be removable. All 3-phase units offer belt drive. The base rails of the unit shall have provisions for forklift and crane lifting. and 100 percent run-tested before leaving the factory. scroll type compressors with centrifugal type oil pumps. drawthrough in the vertical discharge position. heavy gauge. The assembly includes direct drive gear driver. Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring.4°C). Optional differential enthalpy control shall be field-installed. The unit’s base pan shall have no penetrations within the perimeter of the curb other than the raised 1-1/8⬙ [28. Internal overloads shall be provided with the scroll compressors. available for all units. Roof Curb—The roof curb shall be designed to mate with the unit’s downflow supply and return openings and provide support and a watertight installation when installed properly. hermetic. All motors shall be thermally protected.S. odorless glass fiber material and secured with adhesive and mechanical fasteners. Unit Top The indoor top cover shall be one-piece construction. Remote Potentiometer—Field installed.7°C) and 50°F (4. 3/8⬙ [9. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection.Mechanical Specifications RLNL-B Series General Compressors Accessories/Option Units shall be convertible airflow. Indoor Fans Motorized Outside Air Dampers— Field-installed manually set outdoor air dampers shall provide up to 50 percent outside air. shall be factory-installed as standard. 24-volt electromechanical control circuit shall include control transformer and contactor pressure lugs for power wiring.8 mm]. galvanized steel. All insulation edges shall be either captured or sealed.58 mm] high downflow supply return openings to provide an added water integrity precaution. Cooling performance shall be rated in accordance with DOE and/or AHRI testing procedures. Unit’s surface shall be tested 1000 hours in a salt spray test in compliance with ASTM B117. Refrigerant Circuits Each refrigerant circuit shall have TXV (except 073) small orifice refrigerant control expansion device. Service pressure ports. All indoor fan motors meet the U. FC centrifugal fans with adjustable motor sheaves. fully charged with R-410A. Exterior surfaces shall be cleaned. All units shall be factory assembled. 236-M90 for central cooling air conditioners. shall provide exhaust of return air. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Controls Oversized Motors—Factory installed belt drive oversized motors shall be available for high static applications.53 mm] copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. The base of the unit shall be insulated with foil-faced material. outdoor air dampers shall open to set position when indoor fan starts. in either manual or automatic changeover. Heat Exchanger door and blower doors. along with energy savings potential. for field installation. All scroll compressors shall include Internal Pressure Relief as standard.Mechanical Specifications RLNL-B Series Through the Base Electrical Access—An electrical service entrance shall be factory provided allowing electrical access for both control and main power connection inside the curb and through the base of the unit. The switch will be UL/CSA agency recognized. The disconnect switch will be installed in the unit in a watertight enclosure with access through a hinged door. High Pressure Cutout—High pressure cutout shall be standard on all models and 1/4 turn fasteners. compressor operation will be temporarily interrupted. . Factory wiring will be provided from the switch to the unit high voltage terminal block. Freeze/Clogged Filter Switches—This factory or field-installed option allows for individual fan failure or dirty filter protection. than the standard dry bulb control. 66 Rely on Ruud. This control option offers the highest level of comfort control. Automatic programmable electronic with night set back shall also be available. plus energy efficiency available. This is due to the additional wet bulb sensing capability. Thermostats—Two stage heating and cooling operation shall be available. If indoor coil gets too cold due to low airflow.™ Differential Enthalpy—Adds on to the standard single control with other enthalpy sensors that compare total heat content of the indoor air and outdoor air to determine the most efficient air source. molded case disconnect switch with provisions for through the base electrical connections are available. Low Ambient Cooling—Electromechanical models have cooling capabilities to 40°F as built. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit over current protection. Hinged Access Doors—Stainless steel metal hinges and 1/4 turn fasteners are standard on the Filter/Electrical Access Door. Enthalpy control offers a higher level of comfort control. or to 0°F by adding the optional low ambient (frostat) control. Through the Base Electrical with Disconnect Switch—Factory-installed 3-pole. Enthalpy Control—Single Enthalpy Control shall be standard for all economizers. Option will allow for field installation of liquid-tight conduit and an external fieldinstalled disconnect switch. ™ 67 .Wiring Diagrams RLNL-B Series Rely on Ruud. Wiring Diagrams RLNL-B Series 68 Rely on Ruud.™ . Wiring Diagrams RLNL-B Series Rely on Ruud.™ 69 . ™ .Wiring Diagrams RLNL-B Series 70 Rely on Ruud. ... in accordance with the terms of the limited warranty................ GENERAL TERMS OF LIMITED WARRANTY* Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated................... including applicable terms and conditions.....................One (1) Year *All other parts and components carry a limited warranty of five years.................... provided they are single-phase products installed in a residential application... contact your local contractor or the Manufacturer for a copy of the product warranty certificate............Five (5) Years Parts .... Compressor ..™ 71 .. READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.............Limited Warranty RLNL-B Series BEFORE PURCHASING THIS APPLIANCE.... *For complete details of the Limited and Conditional Warranties......... Rely on Ruud. S. Arkansas 72917 • www.™ PRINTED IN U. 1 . Ruud Heating.ruud. Ruud reserves the right to make changes without notice. Unit 1 Brampton.A 10/12 QG FORM NO. Ontario • L6Y 0P5 Rely on Ruud.com Ruud Canada • 125 Edgeware Road. Cooling & Water Heating • P.O.In keeping with its policy of continuous progress and product improvement. S22-956 REV. Box 17010 Fort Smith.
Copyright © 2024 DOKUMEN.SITE Inc.