Home
Login
Register
Search
Home
RU10 RAN1323 Extension of SIB11
RU10 RAN1323 Extension of SIB11
March 25, 2018 | Author: Jeffrey Price | Category:
Nokia
,
Trademark
,
Information
,
Technology
,
Computing
DOWNLOAD
Share
Report this link
Comments
Description
Nokia Siemens Networks WCDMA RAN System, Rel. RU10, Pre-release Documentation RAN1323: Extension of SIB11 (SIB11bis) Feature Introduction Confidental 1 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT This document and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. Nokia Siemens Networks will. Nokia Siemens Networks will correct errors in the document as soon as possible.SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT. Wave logo is a trademark of Nokia Siemens Networks Oy.The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. and no part of it may be used. explain issues which may not be covered by the document. REVENUE. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENT OR FOR ANY DAMAGES. Siemens is a registered trademark of Siemens AG. or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively in a separate agreement between Nokia Siemens Networks and the customer. and they are mentioned for identification purposes only. This document is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted. However. All rights reserved. Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. INDIRECT. BUSINESS INTERRUPTION. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. Confidental 2 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> . if deemed necessary by Nokia Siemens Networks. Nokia is a registered trademark of Nokia Corporation. BUSINESS OPPORTUNITY OR DATA. DIRECT. reproduced. INCIDENTAL OR CONSEQUENTIAL OR ANY MONETARY LOSSES. and the customer assumes full responsibility when using it. The document has been prepared to be used by professional and properly trained personnel. modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. Other product names mentioned in this document may be trademarks of their respective owners. capacity. Copyright © Nokia Siemens Networks 2007. The information or statements given in this document concerning the suitability. INCLUDING BUT NOT LIMITED TO SPECIAL. 2 dd.1 04.yy Author/Approver Material ready for conversion.yy Author Draft… 0. ready for conversion” in the PI Version description field when checking document in PI.mm.yy Author Second Draft 0.07 Minna Nevalainen Inital Draft 0.mm.n dd.yy Collaborator Material ready for publishing.0.0.mm.0.0 dd.mm.09.0.1.1.0 dd. Confidental 3 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> .Version history <This slide to be removed from the customer version> Version Date By Comments 0.2. 0. Note: Add text ”Version 0. Versioning of the materials (see the previous slide) 4. The category folders are in the RU10 pre-release 1 folder mentioned above.1. be careful not toDRAFT include any internal information<dnxxxxxxx> in this set. with the following restrictions: ▪ Try not to change the order of the slides. You can use it as it best fits the feature in question. ▪ Slide 2: Is our Disclaimer i. ▪ Slide 1: Add just the feature name in the brackets (capitalised initial letters).e. Inform Teija Wunsch by e-mail that the material is ready for conversion. try to avoid inserting any (. keep in mind that this material will be delivered to the customers. As the materials will be converted to PDF for customer delivery. . Note: Please. Storage for the materials: – – – Store the training material slide set in the category folder in PI.doc. This template can be found in PI folder: Projects/WCDMA RAN/System Programs/RU10 System Program/Customer Documentation/Customer Documentation Masters/RU10 pre-release 1 2. The links will disappear in the conversion.Instructions <This slide to be removed from the customer version> 1. legat text. please mark clearly in the PI version description field ” Version 0.ppt. Once your slide set is ready for conversion (-> publishing). ready for conversion”.xls) attachments into the slide set.0. 2. . Issue <y-y> Confidental 4 © Nokia Siemens Networks . Please do not touch . Creating the materials: – – The purpose of this template is to harmonise the contents of this customer delivery and to provide you guidance as to which information is typically requested by the customers on features. When relevant neighbours are missing from the SIB11. SIB11bis solves an inconsistency problem in 3GPP TS 25.331. Confidental 5 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> . which may lower the performance in call success rates. In demanding environments. but in the specifications the physical size of SIB11 data has capacity only for 47 cells. the UE cannot make optimal cell selection. which has prevented the usage of complete neighbouring cell lists for idle mode UEs. 3GPP R6 introduces SIB11bis. System Information Block type 11bis (SIB11bis) provides extension segments for SIB11. 32 inter-frequency and 32 inter-system neighbouring cells for idle mode UEs.Introduction This feature belongs to operating software. the interfrequency and inter-system neighbour cell lists may remain incomplete. which allows operator to define 32 intra-frequency. All these neighbours were originally intended to be included in SIB11. As the intra-frequency neighbours are typically given the highest priority. the existing size of SIB11 may not be enough. SIB11bis is a backward compatible solution to correct the problem in SIB11. Benefits for the operator Complete neighbouring cell lists can be provided to guarantee the optimal cell re-selection and end-user QoS. Confidental 6 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> . SIB11 is guaranteed to be able to contain 47 as maximum number of neighbors with any configuration (35 if HCS is used). After the decoding UE has full knowledge of all defined neighbouring cells Confidental 7 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> . Then the encoded RRC SYSTEM INFORMATION message and the transmission schedule is transmitted to BTS using NBAP: SYSTEM INFORMATION UPDATE REQUEST message. inter- frequency and/or inter-system) becomes greater than can be encoded to • • • • SIB11. BTS then decodes the NBAP message and starts to transmit RRC SYSTEM INFORMATION messages according the given schedule. UE then receives and decodes the contents the RRC SYSTEM INFORMATION message. The amount of neighbouring cells that can fit to SIB11 depends on the parameter values of neighbouring cells. SB1 and SIB18 are updated accordingly and transmission schedule is calculated.Functional description • When the amount of defined neighbouring cells (intra-frequency. SIB11bis is taken to use. The remaining neighbouring cells are encoded to SIB11bis and MIB. SB1 and SIB18 • Update to MIB and SIB1 is the support of the new SIB type extension IE • Update to SIB18 is the support of listing the PLMN identities for the cells present in SIB11bis Confidental 8 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> .331 are done to contents of MIB.Implementation in RAN • New SIB type is introduced to NBAP and RRC protocols • The neighbouring cells that do not fit into SIB11 are packed to SIB11bis • When SIB11bis is used corresponding updates required by the 3GPP TS 25. Signaling flows • Message flow has not been changed or updated due to this feature. Confidental 9 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> . 0 WBTS 5. Confidental 10 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> MGW UE . 1 • HW requirements – This feature does not require any additional HW.HW/SW requirements • SW requirements Release RAS RNC BTS Ultra BTS Flexi BTS Pico BTS NBxxx RU10 RN4.0 X NBxxx _RU10 AXC NetAct MSC SGSN OSS5.0 WBTS 5. this feature is supported by default in RU10 • How to verify/monitor? – Message monitoring on Iub interface should show SIB11bis present in NBAP: SYSTEM INFORMATION UPDATE REQUEST message – Message monitoring on Uu interface should show SIB11bis present in RRC SYSTEM INFORMATION message • How to deactivate? – No deactivation. this feature is supported by default in RU10 Confidental 11 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> .Activation and operation • How to activate? – No activation. Interdependencies between features • Dependencies/effects/connections to other features – No dependencies/effects/connections to other features Confidental 12 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> . Management data • Parameters – There are no parameters related to this feature. • Counters – There are no counters related to this feature. Confidental 13 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> . Related customer documents • According to current plans. the following documents in later customer documentation deliveries will include further information on this feature ???? (is there any?) Confidental 14 © Nokia Siemens Networks DRAFT <dnxxxxxxx> Issue <y-y> .
Report "RU10 RAN1323 Extension of SIB11"
×
Please fill this form, we will try to respond as soon as possible.
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
Copyright © 2024 DOKUMEN.SITE Inc.