RTU560 ABB

March 27, 2018 | Author: Mostapha Benali | Category: Direct Current, Power Supply, Input/Output, Modem, Digital Electronics


Comments



Description

PSN-PX 10.11.2010 RTU560/RTU211 Modules 1KGT 150 648 V1.02 © ABB Group February 18, 2012 | Slide 1 Modules Contents RTU560 rack solutions  Subracks  CMUs  I/Os  Communication modules  Auxiliary RTU560/RTU211 DIN rail solutions  CMUs  I/Os  Communication modules  Auxiliary RTU560E © ABB Group February 18, 2012 | Slide 2 Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18, 2012 | Slide 3  560CSR01  Available for wall mounting and swing frame  Supports redundant power supplies  Up to 8 communication modules  Expansion slot for 560BCU01  Real time clocks 560RTC01/02/03  Network modules 560NUS04/12  No I/O module . 2012 | Slide 4 560BCU01 1.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary 560CSR01 560PSU02 NCC(s) 560PSU02 24 V 24 V 5V 5V UE + UE + UE - UE - 560CMU05 560CMU05 560CMU05 560CMU05 ERR ERR ERR ERR 560BCU01 ALR WRN E1 E1 E1 E1 E2 E2 E2 E2 TSI TSO SEB PE PE 1...16 serial lines or Ethernet links A E 1 A E 1 A E 1 A E 1 B E 2 B E 2 B E 2 B E 2 ON ON OFF OFF 560CSR01 System bus Distance < 2m 560CSR01 (opt.) 560PSU02 560PSU02 24 V 24 V 5V 5V UE + UE + UE - UE - PE PE ON OFF 560CMU05 560CMU05 560CMU05 560CMU05 ERR ERR ERR ERR ALR WRN E1 E1 E1 E1 E2 E2 E2 E2 TSI TSO SEB A E 1 A E 1 A E 1 A E 1 B E 2 B E 2 B E 2 B E 2 ON OFF IEDs © ABB Group February 18.. 32 subdevice lines (serial or Ethernet) with 1> 32 IEDs per subdevice line . 18 slots © ABB Group February 18.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary  Redundant power supply.000 data points) or 560CMU02R0002 are supported  Solely CMU rack with 560CMU02 and 560CMU05 Mixed configurations with CMU and I/O   Single power supply. 17 slots 560MPR03 & 560SFR02  Available for wall mounting (560MPR03) and swing frame (560SFR02)  Supports 1 or 2 power supply units (560PSU01/02)  Up to 8 units 560CMU05 (up to 5. 2012 | Slide 5 Mixed configurations with 560CMU05 and 560CMU02 (limited to 750 data points in the RTU) . 2012 | Slide 6 23ET24 and 23TP22  23TP22 version for mounting plate mounting  23ET24 version for swing frame mounting  1 slot for power supply (560PSU01/02)  19 general purpose slots  All rack mounted I/O modules  Real time clocks 560RTC01/02/03  Up to 2 communication modules  Communication media interfaces  Used as Basic rack  I/O extension rack  .Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary  23ET24 23TP22 © ABB Group February 18. Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18, 2012 | Slide 7  560MPR01  1 or 2 Slots for 560CMU02 or 560CMU05  Up to 8 slots for I/O modules  24 V DC external power supply  Extension connector for I/O bus (extension rack, I/O modules 110/220 V DC)  Alarm and warning contact output  Separate input for process voltage (48>60 V DC)  Power distribution for monitoring and command voltage  23BA22 configurable for 1,5 pole command outputs  Screw connectors, access from front Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary  560BCU01 R0001       Alarm and warning contacts Minute pulse in- and output 560BCU02 R0001  Bus Connection Unit for 23 TP 22  Alarm and warning contacts  Minute pulse in- and output 560BCU03 R0002  Bus Connection Unit for 23 ET 24  Alarm and warning contacts Minute pulse in- and output  © ABB Group February 18, 2012 | Slide 8 Bus Connection Unit for 560 CSR 01 Connecting extension communication rack Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary   © ABB Group February 18, 2012 | Slide 9 560BCU04 R0001  Bus Connection Unit for 560MPR03/23TP22  Basic board for extension of 2 units 560CMU0x  Alarm and warning contacts  Minute pulse in- and output 560BCU04 R0002  Bus Connection Unit for 560MPR03  Extension kit for 10 additional 560CMU0x  Alarm and warning contacts  Minute pulse in- and output and output .and output 560BCU05 R0002  Bus Connection Unit for 560SFR02  Extension kit for 10 additional 560CMU0x  Alarm and warning contacts  Minute pulse in. 2012 | Slide 10 560BCU05 R0001  Bus Connection Unit for 560SFR02/23ET24  Basic board for extension of 2 units 560CMU0x  Alarm and warning contacts  Minute pulse in.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary   © ABB Group February 18. 1x RS485 2x RS232 or RS485 2x 10/100 Base T 2x 10/100 Base T 1x 10/100 Base T 2x 10/100 Base T Up to 10.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary Serial interfaces Ethernet interfaces Number of data points 560CMU05 R0001 560CMU05 R0002 560CMU02 R0001 560CMU02 R0002 4x RS232 or RS485 4x RS232 or RS485 2x RS232. 2012 | Slide 11 Yes .000 data points (depending on configuration) Up to 10.000 data points (depending on configuration) Up to 750 data points Up to 750 data points Yes No Support of Multi.Yes CMU © ABB Group February 18. Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary  560CMU05 R0001 and R0002  Interfaces 4 serial interfaces (RS232C or RS485)  2 Ethernet ports (10/100BaseT) for communication to  Host systems and/or  Subordinated devices and/or  RTU I/O   CPU       © ABB Group February 18. Conitel) are supported only by 560CMU05 R0002 . 2012 | Slide 12 AMD ELAN520 CPU @133MHz 128 MB flash memory 64 MB RAM Web server for diagnosis and maintenance via Ethernet ports PLC capable Bit protocols (Hitachi. on backside) CPU  AMD ELAN520 CPU @133MHz  128 MB flash memory  64 MB RAM  Only one slot width  Usable in single CMU configurations  Maximum of 750 data points .Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary  560CMU02 R0001   © ABB Group February 18. 2012 | Slide 13 Interfaces  3 serial interfaces (2x RS232. 1x RS485)  1x Ethernet 10/100 BaseT  1x IO Bus (RS485. on backside) CPU  AMD ELAN520 CPU @133MHz  128 MB flash memory  64 MB RAM  Only one slot width  Usable in multiple CMU configurations  Maximum of 750 data points . 2012 | Slide 14 Interfaces  2 serial interfaces (RS232 or RS485)  2x Ethernet 10/100 BaseT  1x IO Bus (RS485.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary  560CMU02 R0002   © ABB Group February 18. ..Modules Rack I/O modules ..20 VDC / ±2 / ±5 / ±10 / ±20 / ±40mA 23AA21 ±2.20mA . 2012 | Slide 15 Binary input Binary output Analog input Analog output 23BE23 16 inputs 24>60 VDC / 2mA 23BA20/22 24>60 VDC / 2A 23AE23 0.Overview Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18..5 / ±5 / ±10 / ±20mA or 4.  LED's for signalization of input channels .Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. counters)  Galvanic insulation by optocouplers  Input voltage 24..60 VDC. double point indications. 2012 | Slide 16  Binary input board 23BE23  16 binary input channels  One module for all types of binary input signals ( single indications.. digital measured values. double point commands. setpoint commands)  Galvanic insulation by relays  Output voltage 24..Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18..60 VDC  Switching capacity: 40 VA (L/R=30ms) @ 60 VDC  Continuous current: 2A . 2012 | Slide 17  Binary output board 23BA20  16 binary relay output channels  One module for all types of binary output signals (single commands. 2012 | Slide 18  Command Output monitoring board 23BA22  Usage in combination with 23BA20  1 out of n check  Supervision of up to 32 different relay types  Galvanic isolation of the check circuit  Suppression of line frequency during measuring  Monitoring of output duration and reset in case of fault  Monitoring of switching voltage before and during the command output .Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 20 VDC  12 bit + sign = 4096 steps  Occupies one slots in RTU560 subrack  Low-pass filter  Over voltage protection . ± 20 mA. ±10 mA. ± 5 mA. 0. ± 40mA  Input voltage ± 2 VDC. 2012 | Slide 19  Analog input board 23AE23  8 differential inputs  Input current ± 2 mA..Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18.. 2012 | Slide 20  Analog output board 23AA21  2 channels  Output current ± 2. ± 5 mA...5 mA.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. +-10 mA. ± 20 mA or 4.20mA  11 bit + sign  Occupies one slots in RTU560 subrack . Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2012 | Slide 21 Analog line modems Serial optical interfaces Ethernet and optical switches 23WT23/24/25 5/24 VDC 23OK24 560NUS04/12 unmanaged 560NMS24/34 managed/DSL . or 4-wire lines.23  2. 2012 | Slide 22  Modem 23WT23  FSK modem for voice band range (300-2400 Hz) according to CCITT V. duplex or half duplex  Baudrate 1200 bit/s  Adjustable by jumpers  Point to point or multidrop configurations. in multidrop configurations up to 10 remote station in one line  Disconnect test sockets on front side  Only one slot necessary  R0001: 5 VDC.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. R0002: 24 VDC . Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. multi-drop configuration  Disconnect test sockets on front side  Only one slot necessary .or 4-wire lines. Point to point  Distances up to 10 km. duplex or half duplex  Baudrate: 9600 Baud  Distances up to 20 km. 2012 | Slide 23  Modem 23WT24  FSK modem for wide band range (300-18000 Hz)  2. duplex or half duplex Baudrate 50 bit/s if 24-channel-CCITTraster is used. 2012 | Slide 24 FSK modem in voice band range (3002400Hz) according to CCITT Variants: R0001: supply voltage 5 VDC R0002: supply voltage 24 VDC 2. up to 2400 bit/s if one channel is used Digital signal processor (DSP) for conversion of binary information to voice band and vice versa Point to point or multi-drop configurations.or 4-wire lines.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary  Modem 23WT25        © ABB Group February 18. in multi-drop configurations carrier can be switched off Disconnect test sockets on front side . Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18.5)  Cable length up to 2600 m . 2012 | Slide 25  Optical coupler 23OK24  Optic connection of extension racks in star or line configuration  Optic connection of SPA bus devices point to point or loop  Optic connection of protection devices according IEC 60870-5-103  Glass fiber optic wave length 820 nm  ST connector (BFOC 2. Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2012 | Slide 26  4 port unmanaged local switch – 560NUS04  4 fast Ethernet 10/100 BaseT ports for LAN port multiplication  Additional interfaces for diagnosis and LAN/WAN communication  Unmanaged  Auto negotiation 10/100Mbps  Automatic Cross over detection  Only for linear networks (no ring configuration)  No STP/ RSTP supported  No additional power supply required  Plug and play – no configuration required . Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary  4 port switch with 2 x FX – 560NUS12  2 fast Ethernet 10/100 BaseT ports  2 SFP cages for fiber optical interfaces  Unmanaged  Auto negotiation 10/100Mbps  Automatic cross over detection  Different SFPs 560NFO13: mono-mode fiber. 2012 | Slide 27 Only for linear networks No STP/RSTP supported Media converter to optical Ethernet Plug and play – no configuration required . up to 40 km  560NFO85: multi-mode fiber. up to 15 km  560NFO15: mono-mode fiber. up to 2 km      © ABB Group February 18. 2012 | Slide 28  4 port switch with 2 x DSL 560NMS24  SDSL interface (Symmetric Digital Subscriber Line)  4 x fast Ethernet RJ45 ports  2 DSL WAN ports for copper  Bandwidth from 192kbit/s up to 6Mbit/s  Automatic through-connection in case of power cut  Managed switch  Ring configuration possible  NMS34 with 1 DSL port .Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2012 | Slide 29 Power supply units Real time clocks 560PSU01/02 560RTC01/02/03 . ..5.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18..5 A and 24 VDC: 0.. short circuit proof.7 A  1 LED for 5V.60 VDC (R0001) or 110. 5 VDC: 0..220 VDC (R0002)  Output total 44 W. 2012 | Slide 30  Power supply unit 560PSU01  Input: 24..0...2 A . controlled load balancing  Alarm indication relay in case of failure . 1 LED for 24 V signalization  Electronic power limitation. short circuit proof. controlled load balancing  Alarm indication relay in case of failure  Stipulated for redundant operation . 5 VDC: 0>15 A and 24 VDC: 0... 1 LED for 24 V signalization  Electronic power limitation.. 2012 | Slide 31  Power supply unit 560PSU02  Input: 48.Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18.0.7 A  1 LED for 5V..220 VDC  Output total 80 W. 2012 | Slide 32  Real time clock 560RTC01/02/03  560RTC01: designed for GPS receiving  560RTC02: designed for long-wave DCF 77 transmitter receiving  560RTC03: IRIG-B time codes  IRIG-B123  IRIG-B122  AFNOR NFS 87-500  IRIG-B003  IRIG-B002  AFNOR NFS 87-500 (DC) .Modules RTU560 rack solution Subracks CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2012 | Slide 33 1 16 binary inputs 8 binary outputs 8 analog inputs (mA) Binary inputs/outputs Analogue inputs/outputs Direct analog inputs Optional: fault current detection 204 x 105 x 55 mm 230 x 150 x 84 mm .Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary 560CMG10 560CIG10 3 Serial interfaces Ethernet 10/100 BaseT Integrated I/Os Extension I/O modules Dimensions WxHxD © ABB Group February 18. Modules RTU560/RTU211 DIN rail solution DIN rail RTU211 Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2012 | Slide 34 23CM61 560CMU01 Serial interfaces 1/4 3 Ethernet 10/100 BaseT Integrated I/Os 0 1 16 binary inputs 8 binary outputs Up to 4 of the following modules: 16 binary inputs 8 binary outputs 6 analog inputs (mA) 2 analog outputs 6 temperature sensors Extension I/O modules Binary inputs/outputs Analog inputs/outputs Binary inputs/outputs Analog inputs/outputs Direct analog inputs Optional: Fault current detection Dimensions WxHxD (290 – 400) x 116 x 81 mm (181 – 741) x 116 x 81 mm Depending on integrated I/Os . Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2012 | Slide 35  23CM61  512 kByte flash memory  256 kByte RAM  4 x RS232 ports  RP570 communication protocols  IEC 60870-5-101 or DNP3 communication protocols  Built-in “Local Automation Function” (LAF)  Monitoring of system power  Integrated alarm relay  16 binary inputs  8 binary outputs  6 analog inputs  1 out of n check . split to:  + 5 V DC and 1 A = 5 Watt  + 15 V DC and 0.5 A = 7.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary  RTU211 based on 560CMU01  560CMU01    Up to 4 of the following I/O modules:       16 binary inputs 8 binary outputs 6 analog inputs (mA) 2 analog outputs 6 temperature sensors 560PSU10  © ABB Group February 18. 38 W.5 A = 7. 2012 | Slide 36 3 serial interfaces 1 ethernet interface Total output of approx.5 Watt  15 V DC and 0.5 Watt  + 18 V DC and 1A = 18 W . 2012 | Slide 37 560CVT10 Analog inputs .Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary Binary input Binary output Analog input Analog output 23BI61 16 inputs 24/ 48/ 60 VDC 23BO62/63 3A @ 110 VDC / 3A 23AI60 Analog inputs mA DC 23AO60 Analog output mA DC 23BE40 23BA40 560CVT02 16 inputs 110/ 220/250 VDC 50 VA (L/R=40ms) @ 220 VDC / 8A Analog inputs A/V AC 23BE50 64 inputs 24/ 48/ 60 VDC © ABB Group February 18. 2012 | Slide 38  Binary input 23BI61  16 binary inputs for single or double indication. digital measurands.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. pulse counter  R0001: 24>48 VDC  R0002: 60>110 VDC  Grouped with common return per 8 inputs  One LED per input  1 ms time resolution  Length 105 mm  Housing should be ordered separately . 2012 | Slide 39  Direct process-interface 23BE40  16 binary input channels  Input Voltage  110 VDC: 23BE40 R0011  220 VDC: 23BE40 R0012  Inputs without common return  Galvanic insulation by optocouplers  Input current 1.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18.5 mA (chopped)  Oxide film break function for 8 inputs  LEDs for signalization of input channels  Power supply: 24 Vdc . Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2012 | Slide 40  64 binary input module 23BE50  64 binary inputs  Input range: 24>60 VDC  Input functions as 23BE23  Groups with common return per 16 inputs  Galvanic insulation by optical couplers  LEDs for signalization of each input channel  Power supply: 24 VDC  Usable without additional terminals . Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 1.5 or 2 pole commands  Isolated outputs  One LED per output  High switching capacity: 3A @ 110 VDC  Continuous current: 3A  Length 140 mm  Housing should be ordered separately . 2012 | Slide 41  Binary output 23BO62  8 binary relay outputs for 1. Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2012 | Slide 42  1 out of n check 23BO63  1 out of n supervision in combination with 23BO62  High switching capacity up to 110 VDC. 3 A  Length 70 mm  Housing should be ordered separately . Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 250 VDC/AC  Switching capacity: 50 VA (L/R=40ms) @ 220 VDC  Continuous current: 8A . 2012 | Slide 43  Direct process-interface 23BA40  16 binary relay output channels  Outputs without common return (23BA40 R0011)  Galvanic insulation by relays  Switching voltage max. ± 10 mA. ± VDC. 4>20 mA. ± 10VDC  Length: 70 mm  Housing should be ordered separately . 2012 | Slide 44  Analog input 23AI60  6 analog inputs  Resolution: 11 bit +sign  Accuracy class: 0. +20 mA.25  Ranges: ± 5mA.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. apparent power Active. reactive energy Power factor Frequency Harmonic distortion (THD) Integrated in RTU560 engineering . 2012 | Slide 45 1A: 560CVT02 R00x1 5A: 560CVT02 R00x5 Active.2% Calculated values:       © ABB Group February 18.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary  Direct transducer interface 560CVT02  3 voltage inputs 110 VAC 110 VAC: 560CVT02 R000x (for measurement with voltage transformers)  230 VAC: 560CVT02 R001x (for direct voltage measurement at the low voltage side)   3 Current Inputs     Accuracy: 0. reactive. 300V Accuracy up to 0.2 VA of rating Additional fault current measurement up to 20 x line Over current detection Total harmonic distortion (THD) PLC applications for voltage dip detection available Power supply: 24V DC (± 20%) MODBUS interface Integrated in RTU560 engineering .15VA at 300 V Current 0.2% Low input burden    Over Current Detection  Saturation   Phase x Current Over Current detected   OCx_FV © ABB Group February 18. 2012 | Slide 46 Time  R0011: 1A R0015: 5A Voltage 0.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary  Direct transducer interface 560CVT10  3 current inputs      3 voltage inputs max. ± 10VDC  Length: 105 mm  Housing should be ordered separately .5 mA.25  Ranges: ± 2.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. ± 10 m. ± 1 VDC. ± 20 mA. ± 5mA. 2012 | Slide 47  Analog output 23AO60  2 analog outputs for set points  Resolution: 11 bit +sign  Accuracy class: 0. 4>20 mA. Modules RTU560/RTU211 DIN rail solution Analog line modems Serial optical interfaces 560FSM10/11 18>72 VDC 560FOC40 18..30VDC 560FOC80 5 VDC 23SC60 R008 glass fiber R009 plastic fiber ABB 560FOC80 Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18.. 2012 | Slide 48 . 2012 | Slide 49 560FSM10  V.72 VDC .23 modem  Functionality comparable to 23WT23  Power supply: 18>72 VDC 560FSM11 R0001  9600 baud modem  Functionality comparable to 23WT24  Power supply: 18..Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary  Modem 560FSM10 and 560FSM11   © ABB Group February 18. 5 connector  RS485 electrical interface  Compatible to 23OK22/24 .. 2012 | Slide 50 Serial optical interface 560FOC40 and 560FOC80  Opto coupler unit  Power supply:  560FOC40: 24 VDC (18.30VDC)  560FOC80: 5 VDC  Support of glass fiber (62.5/125µm)  BFOC 2.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary ABB 560FOC80  © ABB Group February 18. 5 optical interfaces per housing available  To be used to connect 23BE40.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 23BA40 and 23BE50 to DIN rail RTUs .. 2012 | Slide 51  Star coupler 23SC60  Used to connect decentralize I/O racks up to 2 km  Versions for different medias  R008x: multi mode glass fiber  R009x: plastic fiber  2. 18V/1A. 2012 | Slide 52 Power supply units 560PSU10 560PSU40 Input 110>220 VDC Output 24 VDC/2. 24V/0.5A Output 5V/1A. ±15V/0.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18.5A 560PSU41 23PU63 Input 24>60 VDC Input 24>110 VDC Output 24 VDC/2.5A 23VG23/24 . 5 A  1 LED for voltage supervision 24VDC  Overload and short-circuit protection  Power good signal available (only 560PSU40)  Parallel peration possible (only 560PSU40) .Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 24 VDC: 2. 2012 | Slide 53  Power supply 23PSU40/41  Input voltage 560PSU40: 110>220 VDC 560PSU41: 24>60 VDC  Max. output power 60 W. This is split to:  + 5 V DC and 1 A = 5 Watt  + 15 V DC and 0.5 Watt  + 18 V DC and 1A = 18 W . 38 W.5 Watt  15 V DC and 0. 2012 | Slide 54  560PSU10  560PSU10: Power supply unit for RTU560 DIN rail in cooperation with 560CMU01  The 560PSU10 supplies a total output of approx.5 A = 7.5 A = 7.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 20%) Output voltage  5V 1A (internal usage)  +/-15V 0.2 A (RS232. AI/AO)  18 V 1A (relays. 2012 | Slide 55 24 – 110 VDC (+/.5A (process voltage) Used in main module 23CM61 and together with 23AD64 .Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary  Power supply 23PU63  25W power supply  Input voltage    © ABB Group February 18. AO)  24V 0. 2012 | Slide 56  Main adapter 23VG23  Input Voltage 115 / 230 V AC without switch over  24 VDC output voltage  Power output 48 W  Output current min. 0.Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. 2A  Integrated components:  Battery charging device  Switch over device  Exhaustive discharge protection .2 A and max. 240 W  24 VDC output voltage  Output current max. 2012 | Slide 57  Main adapter 23VG24  Input Voltage 115 / 230 V AC  Power output approx. 10 A .Modules RTU560/RTU211 DIN rail solution Technical data RTU560 for DIN rail Technical data RTU211 for DIN rail CMUs I/Os Communication modules Auxiliary © ABB Group February 18. mounting and commissioning  No additional housing needed  Mounting space for additional devices . 2012 | Slide 58 Applications:  Small distribution substations  Distributed architectures with decentralized I/O units Benefits:  Cost optimized solution for medium and small data amounts  Easy and fast assembling.Modules RTU560E   © ABB Group February 18. Modules RTU560E •General modules Housing 560HOS80 Communication Unit 560CMU80 © ABB Group February 18. 2012 | Slide 59 Multi I/O 560MIO80 Modem Unit 560MOD8x . 2012 | Slide 60 Housing 560HOS80  Size: 366mm x 258mm x 310mm (H x W x D)  Hinged housing with terminals on the back-plane  IP 30 .Modules RTU560E  © ABB Group February 18. 70°C) 4 analog inputs  Input range  Input current ± 2 mA. 2012 | Slide 61 .....Modules RTU560E  Multi I/O board 560MIO80  16 binary inputs R0001: 24. 5 A    Breaking current (L/R 40ms. 0.60 VDC  R0002: 110. ± 20 mA. ± 40mA Input voltage ± 2 VDC. ± 5 mA.220 VDC   8 binary outputs R0001: technical data according 23BA20  R0002:  Continuous current rating: max.. ± 10 mA.20 VDC  Resolution: 12 bit + sign  © ABB Group February 18.. 33.Modules RTU560E  Modems    © ABB Group February 18. dial up  Data transfer 300 . 2012 | Slide 62 560MOD80  FSK modem V.23 halfduplex  1200 bps 560MOD81  Analog modem.600 bps 560MOD82  GSM modem  Dual band GSM Modul 900/1800 MHz  Compliant with ETSI GSM phase 2 standard  Class 4 (2W @ 900 MHz)  Class 2 (1W @ 1800 MHz) . CP2: 2x RS232 interfaces with opt. 2012 | Slide 63 CPU  CPU ELAN 400 @ 66MHz  16 MB DRAM  32 MB compact flash card . modem socket.Modules RTU560E Modem1 / RJ45 Modem2 / RJ45 CP1 / RJ45  Modem AMD SCC AMD 85C30 SC400 RS232 SMSC DualPort 91C94 RS232 MMI / DB9  CPA: 1x RS485 baudrate 19200 Baud RS485 CPA / RJ45  Opt. baudrate 50 – 38400 Baud DIP32 ISA . Ethernet 10BaseT (RJ45)  1 MMI (Front Access) RS232 baudrate 38400 Baud 37C93x RAM SMSC CP1.BUS 10BaseT / RJ45 RS485  + RS232 E-Bus SPB / Communication interfaces BIOS FPGA 80C251 + DIN41612  Modem ASIC CP2 / RJ45 Com / 2x5Pol Communication unit 560CMU80 Compact Flash AUI / DB15 optional  PC104-Bus © ABB Group February 18. ..Modules RTU560E  Power supply  AC/DC converter 560PSU81   DC/DC converter 560PSU80  © ABB Group February 18.. 2012 | Slide 64 Input voltage: 115.230 VAC Input voltage:  R0001: 24.220 VDC ....60 VDC  R0002: 110. © ABB Group February 18. 2012 | Slide 65 . Revisions © ABB Group February 18.02 Correction of picture file sizes 10.11.2010 V1.09. 2012 | Slide 66 Version Description Date V1.2010 .01 New document 30.
Copyright © 2024 DOKUMEN.SITE Inc.