Rh0287002 Old Emax Fp

March 17, 2018 | Author: Anil Patcha | Category: Electrical Connector, Switch, Transformer, Screw, Fuse (Electrical)


Comments



Description

Installation and service instructionsInstallation, service and maintenance instructions for the fixed part of withdrawable version circuit-breakers RH0287002 L0849 Emax Index 1. 1.1 1.2 Description ............................................................................................................................................................. page 1 General characteristics ................................................................................................................................................................. Fixed part construction characteristics ........................................................................................................................................ « « 1 1 2. 3. 4. 4.1 4.2 4.2.1 4.2.2 4.2.3 4.3 Checking on receipt ............................................................................................................................................... Storage, lifting and weights .................................................................................................................................... Installation .............................................................................................................................................................. Installation room ............................................................................................................................................................................. Installation of the fixed part of withdrawable circuit-breaker ........................................................................................................ Preparation of the fixed part .......................................................................................................................................................... Installation of the fixed part ............................................................................................................................................................ Installation of the fixed part on board a ship .................................................................................................................................. Installation of the flange on the compartment door ....................................................................................................................... « « « « « « « « « 1 1 2 2 2 2 3 4 4 5. 5.1 5.1.1 5.1.2 5.1.3 5.2 5.3 5.3.1 Electrical connections ............................................................................................................................................ Connections to the power circuit ................................................................................................................................................... Shapes of the terminals ................................................................................................................................................................. Examples of layout of the connection busbars according to the types of terminals ................................................................... Assembly procedures of the connection busbars ........................................................................................................................ Earthing ........................................................................................................................................................................................... Cabling the circuit-breaker auxiliary circuits ................................................................................................................................. Withdrawable circuit-breaker ......................................................................................................................................................... « « « « « « « « 5 5 5 5 6 7 7 7 6. 6.1 6.1.1 6.2 6.2.1 6.2.2 6.2.3 Fixed part accessories ........................................................................................................................................... Electrical accessories .................................................................................................................................................................... Auxiliary contacts ........................................................................................................................................................................... Mechanical accessories ................................................................................................................................................................ Accessory for shutter padlock ...................................................................................................................................................... Compartment door mechanical lock .............................................................................................................................................. Mechanical interlock ...................................................................................................................................................................... « « « « « « « 8 8 8 8 8 8 8 7. 8. Overall dimensions ................................................................................................................................................ Electrical circuit diagrams ...................................................................................................................................... « 9 « 16 Dwg. Resp.Off. Take-over Off. Title Language App. Installation, service and maintenance instructions for the fixed part of withdrawable version circuit-breakers Apparatus Doc. N° en Scale Model L0849 Emax RH0287002 ABB SACE the poles and the auxiliary parts. lifting and weights The fixed part. 1 2. 1. not in direct contact with the floor. and covered with a waterproof sheet. after checking it on receipt. Checking on receipt Examine the state of the material received and its correspondence with what was foreseen at the time of ordering. N° 1/24 . b: for E4. insulated from the others. In the withdrawable version. Each pole. make the relative notification within and not over 5 days from receipt of the material. 3 Model L0849 Apparatus Doc. protected by an external wooden housing.2 Fixed part construction characteristics 7 6 1 9 4 8 3 5 1 Supporting structure made of steel sheet 2 Earthing pliers (a: for all versions. it must be put back in its container. the circuit-breaker makes up the moving part of the apparatus which is completed with a fixed part fitted with the terminals for connection to the power circuit of the installation. The structure of the poles differs according to whether the circuit-breaker is selective or current limiting. Fig. Coupling between moving part and fixed part takes place by means of special pliers mounted in the fixed part. The notification must indicate the number of the shipping note. The fixed version circuit-breaker has its own terminals for connection to the power circuit.1. is fixed by means of screws to the transport plate or to the bottom of the packing case. contains the interrupting parts and the current transformer of the corresponding phase. E6) 3 Safety shutters (IP20 degree of protection) 4 Insulating terminal support base 5 Terminals 6 Contacts for signalling racked-in/isolated for test/racked-out (on request) 7 Sliding contacts 8 Padlock for safety shutters (on request) 9 Anti-racking-in lock for circuit-breakers of different size 2b 2a Fig. If the fixed part has to remain in the warehouse even for a short time before being put into service. Caution – Use a dry. 2) – The maximum number of stackable packs is indicated in figure 3. 3. Should any damage or irregularity be found on unpacking. which must be carried out carefully.1 General characteristics The SACE Emax series of circuit-breakers are made up of a steel sheet structure which houses the operating mechanism. N° Emax RH0287002 Scale Pag. 2 Fig. Storage. dust-free room free of aggressive chemical agents as the storage room – Position the fixed part on a horizontal surface. Description 1. but on a suitable support surface (fig. the lifting ropes must be hooked up as shown in the figure. please refer to paragraph 6: “Overall dimensions”. non-corrosive room. dust-free.2. 4 Tab le of the weights of the fixed par ts Fixed part E1 E2 E3 E4 E4/f E6 E6/f 70 Withdrawable 3 poles kg 25 28 38 50 Withdrawable 4 poles kg 28 32 45 48 50 80 85 Note The table regards fixed parts with horizontal rear terminals. Should the anti-racking-in lock have been supplied separately.1 Installation of the fixed part of a withdrawable circuit-breaker Preparation of the fixed part Assembly of the anti-racking-in lock Before installing the fixed part.With regard to lifting.1 Installation Installation room Install the circuit-breaker in a dry. it is necessary to check the presence of the anti-racking-in lock of circuit-breakers with different electrical characteristics from those of the fixed part itself. put in service and eventually ordinary and straordinary maintenance have to be done by skilled personel. Model L0849 Apparatus Doc. N° 2/24 . The operation of installation. However. follow these instructions: the fixed part must be placed on a sturdy resting surface and lifted. that has the detailed knowledge of the apparatus. 4. For preparation of the installation room. Check that the anti-racking-in lock corresponding to the one installed on the fixed part is present on the circuit-breaker (moving part).2 4. proceed to assemble it as follows: – On the self-adhesive plate (4). In this case. N° Emax RH0287002 Scale Pag. Fig. the use of ropes is allowed. Where this is not possible. 4. which gives information on the following points: – minimum installation volumes of the circuit-breakers and derived versions – distances to be respected for circuit-breakers in compartments – overall dimensions of the circuit-breakers – fixing drillings – compartment door drillings. find the assembly position of the stop bolts in relation to the circuit-breaker which is to be housed in the fixed part – Insert the two hexagonal-head screws (1) in the holes found in the previous point as shown in figure – Fix the two screws with the washers (2) and the hexagonal stops (3). and in such a way that it is not subject to shocks or vibrations. preferably by means of a special fork-lift truck. 4. use assembly in switchgear with a suitable degree of protection. washers (2) and nuts (3) (M8 x 16). 6 4. N° Emax RH0287002 Scale Pag. Fig.2. check that the head of the screws does not extend more than 5. N° 3/24 . If other screws are used.5 mm from the base of the fixed part.Example for E1B 08 according to the plate diagram 1 4 2 3 Fig.2 Installation of the fixed part Fix the fixed part by means of the screws (1). 7 Model L0849 Apparatus Doc. whereas there are six for E4 and E6. there are four fixing points. 1 2 3 Note (*) For the E1-E2 and E3 fixed parts. 5 Fig. supplied by ABB SACE. 2. – Apply the flange (1) onto the front of the compartment door. N° Emax RH0287002 Scale Pag. N° 4/24 . for applications on board a ship.3 Installation of the flange on the compartment door (Fig.E6 Spacers Fig. 1 2 Fig.4.E2 . fixing it from the inside by means of the self-threading screws (2). 9 Model L0849 Apparatus Doc. E1 . additional fixing on the sides of the fixed part itself is recommended (the M12 screws and the spacers are not provided in the supply).3 Installation of the fixed part on board a ship Regarding the fixing points of the SACE Emax withdrawable version air circuit-breakers. 9) – Make the compartment door drillings foreseen in the “Overall dimensions” paragraph.E3 Spacers E4 . 8 4. 11 Model L0849 Apparatus Doc. Note: The tables given are and indicative reference for selection of the products. 10 5. In some cases. so the width of the connection busbar should be the same as that of the terminal.1 5.1. For withdrawable circuit-breakers with 6300A rated current.1 Electrical connections Connections to the power circuit Shapes of the terminals Horizontal rear terminals Vertical rear ter minals Front terminals Flat terminals Note The drawings are made to show the type of ter minal in diagram for m. reductions in the width of the connection in relation to that of the terminal are allowed. These values refer to apparatus in the withdrawable version in unsegregated switchgear with degree of protection up to IP31 and the following dimensions: 2300x800x900 (HxWxD) for E1-E2-E3. the use of vertical rear terminals is recommended. Fig. The many different possible for ms of switchgear and the conditions which can affect the behaviour of the apparatus always require the solutions used to be verified. Some examples of possible constructions in relation to the shape and size of the circuit-breaker terminals are given in this paragraph. 2300x1400x1500 (HxWxD) for E4-E6. Different capacities for the connections can be made by working on the thickness and on the number of busbars in parallel.1. The various types of terminals are of constant dimensions per size of circuit-breaker: it is normally advisable to exploit the whole contact surface of the terminal. the table shows the continuous current-carrying capacity values of the circuit-breakers installed in switchgear with the dimensions indicated below. Their sizing must be carefully studied by the switchgear designer. N° Emax RH0287002 Scale Pag. The exact shape of the terminals is given in the “Over all dimensions” chapter. The values refer to a maximum temperature of 120°C on the terminals. Vertical terminals Iu [A] Continuous current-carrying Busbar cross-section capacity [A] [mm2] Horizontal and front terminals Continuous current-carrying capacity [A] Busbar cross-section [mm2] 35°C E1B/N 08 E1B/N 12 E2N 12 E2B/N 16 E2B/N 20 E2L 12 E2L 16 E3S/H 12 E3S/H 16 E3S/H 20 E3N/S/H 25 E3N/S/H 32 E3L 20 E3L 25 E4H 32 E4S/H 40 E6V 32 E6V 40 E6H/V 50 E6H/V 63 45°C 800 1250 1250 1600 2000 1250 1600 1250 1600 2000 2500 3100 2000 2390 3200 3980 3200 4000 4850 5700 55°C 800 1250 1250 1600 1800 1250 1500 1250 1600 2000 2500 2800 2000 2250 3200 3500 3200 4000 4600 5250 1x(60x10) 1x(80x10) 1x(60x10) 2x(60x10) 3x(60x10) 1x(60x10) 2x(60x10) 1x(60x10) 1x(100x10) 2x(100x10) 2x(100x10) 3x(100x10) 2x(100x10) 2x(100x10) 3x(100x10) 4x(100x10) 3x(100x10) 4x(100x10) 6x(100x10) 7x(100x10) 35°C 800 1250 1250 1600 2000 1250 1600 1250 1600 2000 2500 3000 2000 2375 3200 3600 3200 4000 4850 - 45°C 800 1250 1250 1600 2000 1250 1490 1250 1600 2000 2490 2880 2000 2270 3200 3510 3200 4000 4510 - 55°C 800 1200 1250 1530 1750 1250 1400 1250 1600 2000 2410 2650 1970 2100 3020 3150 3200 4000 4250 1x(60x10) 2x(60x8) 1x(60x10) 2x(60x10) 3x(60x10) 1x(60x10) 2x(60x10) 1x(60x10) 1x(100x10) 2x(100x10) 2x(100x10) 3x(100x10) 2x(100x10) 2x(100x10) 3x(100x10) 6x(60x10) 3x(100x10) 4x(100x10) 6x(100x10) - 800 1250 1250 1600 2000 1250 1600 1250 1600 2000 2500 3200 2000 2500 3200 4000 3200 4000 5000 6300 800 1250 1250 1600 2000 1250 1600 1250 1600 2000 2500 3200 2000 2500 3200 4000 3200 4000 5000 6000 As an example. N° 5/24 . as is shown in the following examples.5.2 Examples of positioning the connection busbars according to the types of terminals The connection busbars allow connection between the terminals of the fixed parts and the busbars of the switchgear. 5. Fig. dents or traces of oxidation. N° 6/24 . Always use two wrenches (so as not to stress the insulating parts excessively). Always interpose a flat washer of good diameter and a spring washer between them (to spread the tightening pressure over a greater area). When aluminium connections are used it is advisable to apply a thin layer of Vaseline over the contact surfaces. Make the contact between connection and terminal and fully tighten the fixing screws.1. screws for phase No. In the case where copper connections are used. it is advisable to tin-plate the contact surfaces. remove all traces of grease or dust with a cloth soaked in a suitable solvent. screws for neutral 2 2 3 3 4 4 6 6 Fig. 12 E1-E2 250 250 – – E3-E4-E6 150 150 – – E1-E6 – – 250 250 5. which must be eliminated using a fine file or an emery cloth to prevent localized increases in temperature. applying the tightening torque indicated in figure 11. 13 Model 2 4 3 6 L0849 Apparatus Doc.3 Assembly procedures for the connection busbars Check the state of the contact surfaces of the connections very carefully: these must be very clean and free of burrs.Positioning the first anchoring baffle of the busbars according to the short-circuit current Anchoring to the switchgear HORIZONTAL FRONT VERTICAL FLAT P HORIZONTAL VERTICAL FRONT FLAT Fig. The connections must not exert any force in any direction on the terminals. On completion of the operation. N° Emax RH0287002 Scale Pag. Fixed part terminals No. M12 high resistance screws Tightening torque of the main terminals: 70 Nm. Check tightening after 24 hours. 1 Withdrawable circuit-breaker For connection of the moving part to the auxiliary circuits.E3 5 contacts in position E4 . After assembly. identified by code XF.5. a terminal box is available. N° Emax RH0287002 Scale Pag.3. The connector and terminal box have screw terminals. 1 3 2 E1 .E3 3 1 2 2 1 3 E1 .2 Earthing The fixed part of the withdrawable circuit-breaker has one or two terminals on the rear. marked with the special symbol. 14 Model L0849 Apparatus Doc. Before assembling the connection. 5. for connection to earth (fig. clean and degrease the area around the screw. tighten the bolt with a torque of 70 Nm.E6 10 contacts in position Caption 1) Sliding contacts (X) 2) Ter minal box for position contacts (XF) 3) Position contacts Fig. N° 7/24 . a connector with sliding contacts is available on the fixed part (see figure). 9). Furthermore. There is immediate access to the terminals of the fixed connector with the compartment door open. Each terminal is complete with a bolt for fixing the connection.3 Cabling the circuit-breaker auxiliary circuits 5.E2 . identified by code X on the electrical circuit diagram. A conductor with cross-section conforming to the Standards in force must be used for the connection. for connection of the position contacts of the moving part in relation to the fixed part.E2 . The auxiliary contacts have the following configurations: – 5 contacts: group made up of 2 contacts for signalling racked-in. N° 8/24 . 14) In addition to the mechanical signalling about the position of the circuit-breaker.2. This is only available for circuit-breakers in the withdrawable version.2 Compartment door mechanical lock This prevents compartment door opening with the circuit-breaker closed (and circuit-breaker racked-in for withdrawable circuit-breakers) and locks circuit breaker closing with the compartment door open.2 Mechanical accessories 6. 6.S75T (31-32) . to be installed on the fixed part. 4 types of interlocks are available: type A: between 2 circuit-breakers (power supply group + emergency) type B: between 3 circuit-breakers (group of 2 power supplies + emergency) type C: between 3 circuit-breakers (group of 2 power supplies + bus-tie) type D: between 3 circuit-breakers (group of 3 power supplies / a single circuit-breaker closed) Model L0849 Apparatus Doc.1 Auxiliary contacts Auxiliary contacts installed on the circuit-breaker are available. The installation of the circuit-breakers can be either vertical or horizontal. which allow indication of the circuit breaker status (are also available in gold plated contact version for digital signal).3 T 10 ms Electrical signalling for circuit-breaker racked-in/racked-out test/racked-out (fig.3 Mechanical interlock This mechanism carries out the mechanical interlock between two or three circuit-breakers (even of different sizes and in any fixed/withdrawable version) by means of a flexible cable. N° Emax RH0287002 Scale Pag.S75E (31-32) 6.2.2. The electrical circuit diagram for electrical switching by means of a relay (to be provided by the customer) is supplied with the mechanical interlock.1. 15) This allows the shutters (installed on the fixed part) to be padlocked in the closed position. to be installed on the fixed part.3 A 0. 4 contacts for signalling racked-out and 2 contacts for signalling the test position (main pliers isolated. Characteristics Un 125 V DC 250 V DC Un 250 V AC In max 0. 2 contacts for signalling racked-out and 1 contact signalling the test position (main pliers isolated. 15 6. it is possible to have electrical signalling by means of 5 or 10 auxiliary contacts which are installed on the fixed part.1 Fixed part accessories Electrical accessories 6.6. but sliding contacts connected) – 10 contacts: group made up of 4 contacts for signalling racked-in. Reference figures in the electrical circuit diagrams: S75I (31-32) . 6. 14 Fig.15 A In max 5A cosϕ 0. Fig. but sliding contacts connected). It is only available for circuit-breakers in the withdrawable version.1 Accessory for shutter padlock (fig. 1 M12 screw (E1.5 380 3 225 240 33 393.5 E 199.5 124. E2.5 .5 Max 6 Y A B A 4 POLES 3 POLES E1 E2/E3/E4/E6 E 461 465 140 E 199. E3) or no. E6) for earthing (included in the supply) 5 Run from connected for a TEST to isolated 6 Alternative drilling with 25 mm pitch for fixing fixed part 7 Ventilation drilling on the switchgear 15 33 60 E1/E2 View A 90 Y 327 90 E3 View A 3 POLES 35 ø13 Y 126 126 35 35 96 435 3 POLES ø13 2 4 129 90 100 138 2 4 183 200 240 6 60 417 90 4 POLES 90 35 15 33 96 126 561 126 63 4 POLES 126 35 35 N 174 45 N 309 393.5 40 380 84 122 325 370 F 3 225 240 1 6 175 220 ø10 7 1 ø10 Y Y A B 324 324 432 594 810 - C 162 162 216 252 342 - D 162 162 216 342 342 468 468 E 10 8 8 8 8 8 8 – – 370 530 – 750 - F 3 poles 4 poles – – 490 610 700 870 1000 E1 E2 E3 E4 E4/f E6 E6/f 414 414 558 684 774 936 1062 Model L0849 Apparatus Doc. N° 9/24 1SDC200221F0001 70 49 70 49 1SDC200220F0001 124. N° Emax RH0287002 Scale Pag.7. 2 M12 screws (E4. Overall dimensions Withdrawable circuit-breaker Basic version with horizontal rear terminals 5 3 34 13 5.5 C 465 min 465 E 10 X X 140 E 10 465 min X 3 POLES D 4 POLES 18 Y 348 18 348 Caption 1 Inside edge of compartment door 2 Segregation(where foreseen) 3 Fixing fixed part Ø 10 drilling (use M8 screws) 4 No. Withdrawable circuit-breaker Basic version with horizontal rear terminals E4 View A 150 180 Y 597 35 35 35 45 528 200 15 33 135 687 180 200 180 3 POLES (E4) ø13 2 4 3 4 POLES (E4) ø13 60 N 150 618 245 15 33 N 708 33 393.5 380 33 40 84 122 63 F ø10 3 240 49 7 1 433 433 Y Model L0849 1SDC200223F0001 Apparatus Doc. N° 10/24 .5 380 40 84 122 45 F 180 245 777 180 180 35 35 35 3 4 POLES (E4/f) ø13 150 3 240 49 7 1 290 290 ø10 Y E6 View A 222 252 Y 252 35 35 56 35 35 63 744 310 939 15 33 N 870 370 370 1065 252 252 35 35 56 35 35 96 189 222 252 252 35 35 56 35 35 310 813 3 POLES (E6) ø13 2 4 3 4 POLES (E6) ø13 1SDC200222F0001 3 4 POLES (E6/f) 15 33 N 252 222 ø13 996 393. N° Emax RH0287002 Scale Pag. N° 11/24 .5 114 35 80 A ø13 A ø13 100 134 35 127.5 20 50 3 20 50 3 20 50 3 E1 View A E2 View A E3 View A 90 10 90 N N 126 10 10 12 12 12 90 10 10 10 90 126 N M12 captive screws included in the supply E4 View A E4/f View A E6 View A E6/f View A 180 90 10 10 10 90 135 180 90 10 10 10 90 180 252 12 1012 10 12 126 252 12 1012 10 12 126 N N 189 31 252 31 N M12 captive screws included in the supply M12 captive screws included in the supply N 1SDC200224F0001 Model L0849 Apparatus Doc.5 137. N° Emax RH0287002 Scale Pag.Withdrawable circuit-breaker Version with ver tical rear terminals E1 E2/E4 E3/E6 A ø13 80 114 35 137. 5 20 35 60 90 ø13 20 20 91 90 E3 10 10 N 460 35 35 20 20 91 126 126 100 ø13 Model L0849 1SDC200225F0001 35.5 20 Apparatus Doc. N° 12/24 .Withdrawable circuit-breaker Basic version with front terminals E1 N 460 35. N° Emax RH0287002 Scale Pag.5 10 71 90 35 90 60 20 ø13 E2 10 10 N 460 35. 5 20 35 180 60 70 135 60 60 ø13 35 180 60 70 180 60 60 60 ø13 20 20 20 91 E6 E6 E6/f 10 10 N N N 460 35.5 20 35 35 100 126 189 126 252 ø13 252 35 35 126 100 126 252 20 ø13 20 20 91 Model L0849 Apparatus Doc. N° 13/24 1SDC200226F0001 .Withdrawable circuit-breaker Basic version with front terminals E4 E4 E4/f 10 10 N N 460 35. N° Emax RH0287002 Scale Pag. 5 137. N° Emax RH0287002 Scale Pag.5 3 45 62 3 E1 View A E2 View A E3 View A 90 35 90 60 90 35 90 126 35 35 126 96 N 60 N N E4 View A E4/f View A E6 View A E6/f View A 180 35 150 35 135 60 35 180 35 150 35 35 180 35 252 35 35 222 56 60 35 252 35 35 222 56 35 252 96 N N 189 N N 1SDC200227F0001 Model L0849 Apparatus Doc. N° 14/24 .Withdrawable circuit-breaker Version with flat terminals E1 A E2-E3-E4-E4/f-E6-E6/f A M12 114 114 M12 137. Compartment dimensions Compartment door drilling Y 316 306 ø5 100 100 ø5 100 500 X 339 100 374 384 X Depth 380 100 R2 No. N° 15/24 . 2 holes for IP54 protection 150 168. N° Emax RH0287002 Scale Pag.5 A B 3 POLES 4 POLES Y A B 490 490 630 790 880 1130 1260 E1 E2 E3 E4 E4/f E6 E6/f 400 400 500 700 1000 - Tightening torque of the fixing screws: 20 Nm Tightening torque of the main terminals: 70 Nm Tightening torque of the earthing screw: 70 Nm High resistance M12 screw Quantity per terminal PHASE NEUTRAL N E1-E2 2 2 N E3 3 3 N E4-E4/f 4 2-4 N E6-E6/f 6 3-6 Compartment door mechanical lock Door drillings Minimum distance between the circuit-breaker and the side of the switchgear A 3 Poles 4 Poles E1 E2 E3 E4 E4/f E6 E6/f 180 180 234 270 360 - 180 180 234 360 360 486 486 Model L0849 Apparatus Doc. G against earth fault with inverse short delay trip . 43. PR113/P or PR113/PD release) Applications located on the fixed part of the circuit-breaker (only provided with withdrawable version circuit-breakers) Indicative apparatus and connections for control and signalling.adjustment I1 . The applications indicated in the figures 3. PR113/P or PR113/PD release) Zone selectivity: input (only provided with Uaux..I against short-circuit with instantaneous trip . 5. PR112/PD. Versions The diagram shows a withdrawable version circuit-breaker. PR112/P . PR112/PD. 5. Caption * A1 A13 A3 A4 AY D F1 K51 = = = = = = = = = = Number of figure of the diagram See the note indicated by the letter Applications of the circuit-breaker PR020/K signalling unit (only provided with PR112/P.8 K51/GZin = = = K51/GZout = K51/P1 K51/P2 K51/SZin = = = K51/SZout = K51/YC K51/Y0 K51/Y01 K51/Zin K51/Zout M Q Q/1. Version with electronic PR113/PD release The PR113/PD overcurrent release is fitted with the protection and dialogue unit. 53 and 62 cannot be supplied with this version. The applications indicated in the figures 3..adjustment I2 . outside the circuit-breaker Fuse with delayed intervention PR111.adjustment I3 . The applications indicated in figures 31. 44 and 53 cannot be supplied with this version.L against overload with inverse long delay trip . and PR113/P or PR113/PD release) Zone selectivity: output for protection S or output in “direct” direction for protection D (DFout) (only provided with Uaux. 44. and PR112/P .25 = = = = = = = = Model L0849 Apparatus Doc. but is also valid for fixed v ersion circuit-breakers. and PR113/P or PR113/PD release) Zone selectivity: output for protection G or output in “inverse” direction for protection D (DBout) (only provided with Uaux. Version with electronic PR111 release The PR111 overcurrent release is fitted only with the protection unit. 41... 5. 41. 42. 22. 13. Version with electronic PR112/PD release The PR112/PD overcurrent release is fitted with the protection and dialogue unit. and PR113/P release) Zone selectivity: input for protection S or input in “direct” direction for protection D (DFin) (only provided with Uaux. 41. outside the circuit-breaker SACE SOR TEST UNIT: control/monitoring unit (see note R) Electronic time-delay device of the undervoltage release. 22. 42 and 44 cannot be supplied with this version. 43. 44 and 53 cannot be supplied with this version.adjustment I4 Electrical alarm signalling for operating anomalies of the microprocessor (only provided with Uaux. 43. Version with electronic PR113/P release The PR113/P overcurrent release is fitted only with the protection unit.PR112/PD. and PR112/P or PR112/PD release) Zone selectivity: output (only provided with Uaux. Version without overcurrent release The applications indicated in figures 3. 42. The applications indicated in the figures 22. and PR113/P or PR113/PD release) Programmable electrical signalling (only provided with Uaux. Version with electronic PR112/P release The PR112/P overcurrent release is fitted only with the protection unit. and PR112/P or PR112/PD release) Motor for closing spring charging Circuit-breaker Circuit-breaker auxiliary contacts K51/µP K51/1. Electrical circuit diagrams State of operation shown The diagram is shown in the following conditions: – withdrawable version circuit-breaker. 42 and 43 cannot be supplied with this version. 52. and PR113/P or PR113/PD release) Closing control from PR112/PD or PR113/PD electronic release Opening control from PR112/PD or PR113/PD electronic release Electrical alar m signalling for Y01 release TRIPPED (only provided with PR112/P. 44. PR112/PD. The applications indicated in the figures 22. PR113/P or PR113/PD release) Programmable electrical signalling (only provided with Uaux. Fixed version The control circuits are included between the XV terminals (the X connector is not supplied). 41. 43. 5. 32 and 51 cannot be supplied with this version. 53 and 62 cannot be supplied with this version.8. 51. 41. and PR112/P . N° Emax RH0287002 Scale Pag. open and racked-in – circuits de-energized – releases not tripped – motor operator with springs discharged. Withdrawable version The control circuits are included between the poles of the X connector (the XV terminal box is not supplied). The application indicated in figure 52 cannot be supplied with this version. PR113/P or PR113/PD type electronic overcurrent release with the following protection functions (see note G): . PR112/PD. 42. PR113/P or PR113/PD release) PR020/K signalling unit contacts Zone selectivity: input for protection G or input in “inverse” direction for protection D (DBin) (only provided with Uaux. N° 16/24 .S against short-circuit with inverse or definite short delay trip . The applications indicated in the figures 3. N° 17/24 . Circuit-breaker closing can only take place after having pressed the reset pushbutton Contacts for electrical signalling of circuit-breaker in position of racked-out (only provided with withdrawable version circuitbreakers) Contacts for electrical signalling of circuit-breaker in position of racked-in (only provided with withdrawable version circuit-breakers) Contacts for the electrical signalling of circuit-breaker in position of test (only provided with withdrawable version circuit-breakers) Pushbutton or contact for circuit-breaker closing Pushbutton or contact for circuit-breaker opening Pushbutton or contact for circuit-breaker opening with delayed trip Pushbutton or contact for circuit-breaker opening with instantaneous trip Current transformer located on phase L1 Current transformer located on phase L2 Current transformer located on phase L3 Current transformer located on the neutral Homopolar current transformer located on the conductor which connects the MV/LV transformer star centre to earth (see note G) Insulation transformer Voltage of auxiliary power supply (see note F) Current sensor (Rogowski coil) located on phase L1 Current sensor (Rogowski coil) located on phase L2 Current sensor (Rogowski coil) located on phase L3 Current sensor (Rogowski coil) located on the neutral Serial interface with the control system (external bus): EIA RS485 interface (see note E) Serial interface with the accessories of the PR112/P. Fig. 1 2 3 4 5 6 7 8 11 12 13 21 22 23 31 32 41 42 43 44 51 52 53 = = = = = = = = = = = = = = = = = = = = = = = Closing spring charging motor circuit Shunt closing release circuit Shunt closing release circuit with control from the dialogue unit of the PR112/PD or PR113/PD release Shunt opening release Shunt opening release circuit with control from the dialogue unit of the PR112/PD or PR113/PD release Instantaneous undervoltage release (see notes B and Q) Undervoltage release with electronic time-delay device. Fig. Fig. for fixed version circuit-breaker (see note C) Circuit valid in the case of three-pole circuit-breaker with PR113/P or PR113/PD release without current transformer on the neutral conductor outside the circuit-breaker (see note H) SACE SOR TEST UNIT: control/monitoring unit (see note R) PR020/K signalling unit (only provided with PR112/P .. PR112/PD. PR112/PD. test or racked-out position Second pack of contacts for electrical signalling of circuit-breaker in racked-in. Fig. Fig. 61 = Fig.53 Model L0849 Apparatus Doc.43 . Fig. Fig. PR113/P and PR113/PDA releases). PR113/P and PR113/PD releases Connectors for the auxiliar y circuits of the PR112/P . Fig. N° Emax RH0287002 Scale Pag.44 31 . outside the circuit-breaker (see notes B and Q) Second shunt opening release (see note Q) Contact for electrical signalling of springs charged. Fig. Fig. F and M) Auxiliary circuits of the PR113/P release (see note F) Auxiliary circuits of the PR113/PD release (see notes F and M) Circuit of the current transformer on the neutral conductor outside the circuit-breaker. Fig..41 . PR113/P or PR113/PD release) Fig. First pack of circuit-breaker auxiliary contacts Second pack of circuit-breaker auxiliary contacts (not available with the PR112/P. UI/L1 UI/L2 UI/L3 UI/N W1 W2 X X1.52 . PR112/PD. Fig. PR112/PD. for withdrawable version circuit-breaker Circuit of the current transformer on the neutral conductor outside the circuit-breaker. Fig.42 . Fig. Fig. Circuit-breaker closing can only take place after the reset pushbutton has been pressed. PR113/P and PR113/PD (inter nal bus) releases Delivery connector for withdrawable version circuit-breaker auxiliary circuits Connectors for the circuit-breaker applications Delivery terminal box for the withdrawable version circuit-breaker position contacts (located on the fixed part of the circuit-breaker) Connector for the power circuits of the PR111. Fig. L and S) Contact for bell alarm of circuit-breaker open due to trip of the overcurrent release.S33M/1 S33M/2 S43 S51 S75E/14 S75I/14 S75T/14 SC SO SO1 SO2 TI/L1 TI/L2 TI/L3 TI/N TI/O TU Uaux. Fig. PR112/PD. Fig. Fig. Contact for electrical signalling of undervoltage release energized (see notes B. Third pack of additional circuit-breaker auxiliary contacts outside the circuit-breaker First pack of contacts for electrical signalling of circuit-breaker in racked-in. PR113/P and PR113/PD releases Connector for the YO1 release Delivery terminal box for fixed version circuit-breaker auxiliary circuits Shunt closing release Shunt opening release Overcurrent release Overcurrent release (see note Q) Undervoltage release (see notes B and Q) Description of figures Fig. PR112/P. 62 = Incompatibility The circuits shown in the following figures cannot be provided on the same circuit-breaker at the same time: 2-3 4-5 6-7-8 22 . Fig. Fig. test or racked-out position Auxiliary circuits of the PR112/P release (see note F) Auxiliar y circuits of the PR112/PD release (see note D.XK3 XO XV YC YO YO1 YO2 YU = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Limit contact of spring charging motor Contact for electrical signalling of springs charged Changeover switch for setting remote/local control Contact for bell alarm of circuit-breaker open due to trip of the overcurrent release.51 51 . Fig.X7 XF XK1 XK2 . please consult the apparatus catalogue. see the following documentation: .3. PR112/PD. H) In the case of PR113/P or PR113/PD releases mounted on a three-pole circuit-breaker without connection to the neutral outside. In the case where there is the same power supply for the shunt closing releases and undervoltage releases and automatic circuit-breaker closing is required. PR112/P. The shield must be earthed on the circuit-breaker side and on the current transformer side. the connections to the zone selectivity inputs and outputs must be made using a shielded and corded two-pole not longer than 300m. Instructions to follow for replacement of the PR111. G) Protection against earth fault is available with the PR112/P. P) With PR112/PD and PR113/PD releases. PR113/P or PR113/PD releases: – Take special notice of the notes indicated on the electrical circuit diagrams provided – The contact for electrical signalling of undervoltage release energized (Fig. IEC 60364-41 and CEI 64-8. Model L0849 Apparatus Doc. B) The undervoltage release is provided for power supply branched on the supply side of the circuit-breaker or from an independent source: circuitbreaker closing is only allowed with the trip energized (the lock on closing is made mechanically). M) Connect one of the S75I contacts indicated in fig. Dur ing closing of the power supply contact to YO (short-circuit of terminals 4 and 5). N° Emax RH0287002 Scale Pag. For this reason: . N) With PR112/P. it is necessary to short-circuit the terminals of the TI/N transformer. connect the XV-K14 terminal directly to the XV-K16 terminal (contact S75I does not exist). PR112/PD. T o make out the order. PR113/P and PR113/PD releases . the TEST FAILED and ALARM signals will be activated. 31 or 51 in the way shown in figs. PR112/PD. 11. R) The oper ation of the SACE SOR TEST UNIT system + shunt opening release (YO) is guaranteed starting from 75% of the Uaux of the shunt opening release. Q) The second shunt opening release must be installed as an alternative to the undervoltage trip. N° 18/24 . The coils can be controlled directly from the K51/YO and K51/YC contacts with maximum voltage values of 60VDC and 240-250VAC for PR112/PD. the TEST FAILED signal may be activated at the same moment.5 mA]. 12 of the enclosed diagrams) must be removed from the terminal box.Notes A) The circuit-breaker is only fitted with the applications specified in the ABB order confirmation. the contact indicated in figure 12 and a time-delay relay.In the case of an opening coil supplied continuously. 21 in the way shown in fig. PR113/P and PR113/PD releases b y means of a current transformer located on the conductor which connects the MV/LV transformer star centre to earth. it is necessary to introduce a delay of 30 milliseconds between the instant of consent of the undervoltage release and energisation of the shunt closing release.If the control of the opening coil is carr ied out impulsively. The shield must be earthed on both sides (sensor and circuit-breaker). when the circuit-breaker is to be removed. 42-44. the SACE SOR TEST UNIT is not able to determine the state of the opening coil. refer to the corresponding user manuals. . L) The contact cannot be used if the PR113/P or PR113/PD unit is present. the TEST FAILED signal should only be considered an actual alar m signal if it remains for longer than 20s. In this case. must be made using a shielded and corded two-pole cable (see instruction manual) not longer than 15 m. PR112/PD. on return of the auxiliary voltage.RH0297 for LON communication . In the case of fixed version circuit-breakers. I) The contact cannot be used if the PR112/PD and PR113/PD unit is present. 240-250VDC and 240-250VAC for PR113/PD. For other installation configurations. Having requested a Vaux insulated from earth. 15. please see par. C) In the case of a fixed version circuit-breaker with current transformer on the neutral conductor outside the circuit-breaker. The shield must be earthed on the selectivity input side. the T3 and T4 poles of the X (or XV) connector must be short-circuited (by the customer). S) Also available in the normally closed contact version. This can be carried out by means of a circuit outside the circuit-breaker including a per manent closing contact. the power supply of the YO and YC coils must not be branched from the main one. PR113/P and PR113/PD releases. allows actuation of all operations of the PR112/P. one of the closing contacts and one of the opening contacts of the circuit-breaker indicated in fig. the connection between the voltage sensors (TV) and the circuit-breaker must be made using a shielded and corded two-pole cable not longer than 15 m. E) For connection of the EIA RS485 serial line. In this regard. 42.RH0298 for MODBUS communication F) The auxiliar y voltage Uaux. O) With PR113/P and PR113/PD releases.2. T) Configuration valid for four-pole or three-pole circuit-breaker with external neutral. The connection between terminals 1 and 2 of the TI/O current transformer and the T5 and T6 poles of the X (or XV) connector. one must use “galvanically separated converters” in compliance with IEC 60950 (UL 1950) or equivalent standards that ensure a common mode current or leakage current [(see IEC 478/1 CEI 22/3) not greater than 3. D) Connect the S33M/2 contact indicated in fig. g. 3 conductors) Make position contact (limit switch) Fuse (general symbol) Connection of conductors Break position contact (limit switch) Current sensor Model L0849 Apparatus Doc.. three conductors) Changeover contact Trip unit for ground fault with inverse short time-delay characteristic Conductors or corded cables (e.Graphic symbols for electrical circuit diagrams (IEC 60617 and CEI 3-14. N° Emax RH0287002 Scale Pag. N° 19/24 ..g.3-26 Standards) Shield (can be drawn in any shape) Ter minal or clamp Changeover position contact with momentary trip (limit switch) Timing Socket and plug (female and male) Power molded case switch with automatic opening Mechanical connection Motor (general symbol) Molded case switch Manual mechanical operating mechanism (general case) Current transformer Control coil (general symbol) Rotary handle operating mechanism Voltage transformer Instantaneous trip unit Pushbutton operating mechanism Three-phase transformer winding. star connection Trip unit with shor t adjustable time-delay characteristic Equipotentiality Make contact Trip unit with inverse shor t time-delay characteristic Converter separated galvanically Break contact with with automatic trip Trip unit with inverse long time-delay characteristic Conductors in shielded cable (e. PR112/PD. PR113/PD release and current tr ansformer on neutral conductor outside the circuit-breaker 1SDC200242F0001 1SDC200243F0001 Model L0849 1SDC200244F0001 Apparatus Doc. PR113P . PR112/PD.State of operation Three-pole or four-pole circuit-breaker with electronic PR111. PR113/P and PR113/PD release Three-pole or four-pole switchdisconnector Three-pole circuit-breaker with electronic PR111. PR112/P. N° 20/24 . N° Emax RH0287002 Scale Pag. PR112/P . Motor operator. N° Emax RH0287002 Scale Pag. N° 21/24 . shunt opening release. shunt closing release and undervoltage release Signalling contacts Model L0849 Apparatus Doc. N° 22/24 .Signalling contacts Model L0849 Apparatus Doc. N° Emax RH0287002 Scale Pag. N° Emax RH0287002 Scale Pag. N° 23/24 .Auxiliary circuits of the PR112/P release Auxiliary circuits of the PR112/PD release Model L0849 Apparatus Doc. N° 24/24 . N° Emax RH0287002 Scale Pag.Auxiliary circuits of the PR113/P release Auxiliary circuits of the PR113/PD release Model L0849 Apparatus Doc. Telefax: +39 035.Due to possible developments of standards as well as of materials. ABB SACE S.A. the characteristics and dimensions specified in the present catalogue may only be considered binding after confirmation by ABB SACE. 35 .abb.com RH0287002 L0849 .24123 Bergamo .111 . Breakers Via Baioni.p.306-433 http://www.V.395.: +39 035. L.395.Italy Tel.
Copyright © 2024 DOKUMEN.SITE Inc.