ReleaseNotes Freelance 2016 US

May 31, 2018 | Author: Mario Olivares | Category: Antivirus Software, Microsoft Excel, Software, Operating System, Areas Of Computer Science


Comments



Description

Process AutomationFreelance 2016 Release Notes Power and productivity for a better world TM Freelance 2016 Release Notes NOTICE This document contains information about one or more ABB products and may include a description of or a reference to one or more standards that may be generally relevant to the ABB products. The presence of any such description of a standard or reference to a standard is not a representation that all of the ABB products referenced in this document support all of the features of the described or referenced standard. In order to determine the specific features supported by a particular ABB product, the reader should consult the product specifications for the particular ABB product. ABB may have one or more patents or pending patent applications protecting the intellectual property in the ABB products described in this document. The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any errors that may appear in this document. In no event shall ABB be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. This product meets the requirements specified in EMC Directive 2014/30/EU and in Low Voltage Directive 2014/35/EU. TRADEMARKS All rights to copyrights, registered trademarks, and trademarks reside with their respective owners. Copyright © 2015 by ABB. All rights reserved. Release: Document number: October 2015 2PAA103593R0901 Table of Contents Table of contents Section 1 - Introduction Version Designation...........................................................................................................9 Released Software ..................................................................................................9 Compatible Software..............................................................................................9 Released Hardware...............................................................................................10 Section 2 - New in Freelance 2016 New Product Naming ......................................................................................................11 New Process Station AC 900F Lite.................................................................................11 New in AC 900F..............................................................................................................12 New CAN Communication Interface Module CI 910F .......................................12 Control Net Redundancy......................................................................................12 Extended Temperature Range ..............................................................................12 New in AC 700F and AC 900F .......................................................................................13 Increased Security with Controller Lock .............................................................13 Diagnostic interface (Radio clock).......................................................................14 Freelance Engineering .....................................................................................................14 Engineering Efficiency.........................................................................................14 Database Compression .........................................................................................14 Freelance Operations .......................................................................................................14 Freelance Operations Lite ....................................................................................14 Virtualization of Freelance PCs in ESX-Server ..............................................................15 Section 3 - Known Problems and Workarounds Installation .......................................................................................................................17 Firmware Update from Version 9.1......................................................................17 Freelance Formulation .........................................................................................17 Panel Builder 800 .................................................................................................17 2PAA103593R0901 5 ................................. 29 Section 4 .............................................................................. 23 PROFIBUS . 32 Antivirus program............... 35 I/O modules / E/A-Baugruppen ................................................................................................................................................................................................................................................................................................ 20 Commissioning and Fieldbusses ...Compatible Hardware Versions CPU modules / CPU-Baugruppen ................... 31 Installation of the Software..................................................................................................................... 47 Power supplies / Spannungsversorgungen............................................................................ 28 Bulk Data Manager .................................. 28 General ................................................ 18 General .... 38 Fieldbus modules / Feldbus-Baugruppen ...................... 33 Appendix A ........................ 46 Communication modules / Kommunikations-Baugruppen .....................................................................Installation System Requirements (Operating System) ........ 21 Fieldbus Communication .................................................................................................................... 26 Process Stations.............................................................................. 21 General ............................................................................................... 18 Gateway Station .................................................................................................................................................... 29 Project Export to BDM ........................................................ 32 Setups .............. 28 Control Aspect ........................................................................................................ 44 Ethernet modules / Ethernet-Baugruppen.......... 25 Send and Receive Function Blocks ................................................................................................................................................................. 48 S700 PROFIBUS-slave components / Komponenten des S700 PROFIBUS-Slave49 6 2PAA103593R0901 ..................................................................... 32 Service Hotline .............................................................................................................. 31 Project Upgrade ............................................................................................................................................................................................ 18 Freelance Engineering.............................................................................................................................................................................................................................................................................. 24 Telecontrol IEC 60870-5-101 / 104 ....................................................... 27 Freelance Operations..............................................................Table of Contents Deinstallation ......................................................................................... ....................................................53 2PAA103593R0901 7 ....Table of Contents Compatibility of PM 802F modules.............. Table of Contents 8 2PAA103593R0901 . the lists of devices found compatible with Freelance must be observed. This lists can be found in the ABB Solutionsbank: • 3BDD011925 “Freelance Integrated PROFIBUS Devices”. Refer to the document Packet Assembly List Freelance 2016. this version will be called Freelance 2016.Section 1 Introduction Version Designation Section 1 Introduction This document describes the changes in software version Freelance 2016 as compared to software version Freelance 2013 SP1. • 3BDD011926 “Freelance Integrated HART Devices” and • 2PAA103000 “Freelance Device Management Integrated FF Devices”. Compatible Software With version Freelance 2016 compatible software packages like ABB’s remote I/O DTMs and Control Aspect are provided with the Freelance product CD. Additionally. In the following text. When connecting field devices. it describes problems and errors in the software or documentation that were found too late to be included in the corresponding manual. Version Designation Released Software The basic Freelance System in English and German is the subject of this release. sales information. For further details of the software provided with the Freelance installation CD and version designation refer to the Getting Started manual of version Freelance 2016 2PAA103593R0901 9 .pdf for the full name of the released software version. This document is intended to provide information on the Freelance hardware and software that is not (yet) described in user manuals. or any other kind of product information. Compatible Hardware Versions.Version Designation Section 1 Introduction Released Hardware For all details of the released controllers and IO components refer to Appendix A. 10 2PAA103593R0901 . Section 2 New in Freelance 2016 New Product Naming Starting with this Freelance version some Freelance software components are renamed: Previous Name New Name Control Builder F (CBF) Freelance Engineering DigiVis Freelance Operations CBF Viewer Control Aspect DigiBrowse Archive Browser Configure Settings Trend-Server Freelance Trend Server OPC-Server 800F Trace OPC Server Trace New Process Station AC 900F Lite Starting with this Freelance version the new process station AC 900F Lite with optimized price-performance ratio is supported. Like the previously supported process stations. the AC 900F Lite will be configured with Freelance Engineering and can be used together with the other Freelance controllers. 2PAA103593R0901 11 . Communication between the operator stations and gateway stations (horizontal communication) is only possible via the configured Ethernet line. a redundancy toggle to the redundant line occurs within a configurable changeover time. In the event of a failure of the active line. New in AC 900F New CAN Communication Interface Module CI 910F With this Freelance version the new CAN module CI 910F is released. The AC 900F Lite process station is designed for smaller lines: • • • the number of possible I/O signals is limited to 400. Extended Temperature Range The AC 900F and AC 900F Lite controllers are released for operation in an ambient temperature between -20 °C to +70°C.New in AC 900F Section 2 New in Freelance 2016 Details can be found in the two new manuals Mounting & Installation Instructions AC 900F and Engineering Manual Process Stations. there are only three instead of four Ethernet interfaces available. Control Net Redundancy Optionally. to increase the availability. the available memory capacity and the CPU performance are lower than with the standard version. Communication between AC 900F controllers (lateral communication) and with operator or gateway stations (vertical communication) is done via the active Control Net line. Redundancy is not supported in this case. 12 2PAA103593R0901 . the communication between AC 900F / AC 900F Lite controllers and operator or gateway stations and lateral communication between AC 900F / AC 900F Lite controllers is possible using a Control Net in a redundant configuration. With this new module the AC 900F / AC 900F Lite now allows connectivity to Freelance Rack I/Os based on CAN bus. Section 2 New in Freelance 2016 New in AC 700F and AC 900F New in AC 700F and AC 900F Increased Security with Controller Lock The AC 700F and both AC 900F controllers come with a feature for locking the controller via the display. • The Run/Stop switch on the controller can be disabled in Freelance Engineering. • The AC 900F standard. no commands like “Warm start”. • Web Interface The controller web interface can be protected against unauthorized access in Freelance Engineering. while typical operator access is still possible. Furthermore. as well as the new AC 900F Lite. dedicated engineering changes. • Loading The controller can be protected against subsequent program changes. 2PAA103593R0901 13 . “Cold start” or “Initialize” are possible from Freelance Engineering. New security options • Telnet The controller Telnet interface can be protected against unauthorized access in Freelance Engineering. When locked. a system message is released in Freelance Operations when the SD card is removed. are released for temperatures from -20 to 70 degrees SD card monitoring With activated card monitoring. downloads or firmware updates are disabled. • Improved GSD file handling Database Compression To ensure a secure project work for very large Freelance projects. Freelance Operations Lite The new lite version of Freelance Operations also provides for enhanced scalability of the system. ensure that the transfer rate of radio clock and controller match. When connecting a radio clock. For the 5:4 screen format a monitor screen resolution of 1280 * 1024 pixels is recommended. Freelance Operations With this Freelance version Freelance Operations is now optimized for widescreen displays (16:10 and 16:9). In contrast to the standard version of Freelance Operations.6 kBit/s and 19.2 kBit/s. The Freelance Operations software supports both the conventional screen formats 4:3 / 5:4 and the widescreen formats 16:9 / 16:10. the lite 14 2PAA103593R0901 . for the 16:9 widescreen format a resolution of 1920 * 1080 pixels should be used.2 kBit/s. default value is 19.Diagnostic interface (Radio clock) Section 2 New in Freelance 2016 Diagnostic interface (Radio clock) The diagnostic interface of the AC 700F and AC 900F controller supports now transmission rates of 9. the Freelance project database can be compressed. Freelance Engineering Engineering Efficiency • Improved graphical representation in the hardware structure • Better support and easier configuration of Panel 800 • Graphics Editor improvements to support different screen resolutions and ratio. OPC. …) on an ESX server. It offers an unlimited number of standard displays and only limits the number of graphic displays to five. Virtualization of Freelance PCs in ESX-Server As from this release it is possible to run all Freelance software components (Engineering. It is mainly suitable for smaller plants or the usage of Panel PCs in cabinet doors. Operations. 2PAA103593R0901 15 .Section 2 New in Freelance 2016 Virtualization of Freelance PCs in ESX-Server version is very attractively priced. Virtualization of Freelance PCs in ESX-Server 16 Section 2 New in Freelance 2016 2PAA103593R0901 . 0 does not work with Freelance 2016 If Freelance Formulation shall be used together with Freelance 2016. Then. (#23776 .RN_2016_005): 1) Install Freelance Engineering 2) Install Panel Builder 800 2PAA103593R0901 17 .RN_2016_008). Freelance Formulation V1. For any necessary assistance. please contact your local service organization.1 Upgrade of a process station AC 700F from V9.Section 3 Known Problems and Workarounds Installation Section 3 Known Problems and Workarounds Installation Firmware Update from Version 9.RN_20131_003) Workaround: First load the firmware version 9.0 works with Freelance 2013 / 2013 SP1 only (#24411 . the following installation sequence should be met (#24282 .1 to Freelance 2016 is needed.2 in the process station AC 700F. the firmware version Freelance 2016 can be loaded. Panel Builder 800 Installation of Panel Builder 800 on Freelance engineering station If Panel Builder 800 shall be installed on a Freelance engineering station. the new firmware cannot be loaded directly in one step int the AC 700F process station.1 needs to be installed as Freelance Formulation V1.1 cannot be done within one step If an upgrade of process station AC 700F from version 9. Freelance Formulation Freelance Formulation V1. the "copy/paste" or "drag/drop" function leads to failure with AC 900F During usage of the Hardware Manager in Freelance Engineering it was observed that copying/inserting or dragging/dropping communication interfaces.RN_2016_011).5 is installed as well. the vSphere Client will not be able to start afterwards. Freelance Engineering General In the Hardware Manager. Please use delete/insert functionality only to move interfaces or ports with AC 900F. Please reinstall vSphere Client V5.5 after uninstalling FDT Shared Components (#24368 . Ethernet ports and serial ports at the AC 900F leads to failures. you have to disable Control Net redundancy prior to starting the firmware download. because shared files for both program were removed. (#24579 .Freelance Engineering Section 3 Known Problems and Workarounds Deinstallation After uninstalling FDT Shared Components vSphere Client is not able to start anymore If FDT Shared Components will be uninstalled from a Freelance PC where vSphere Client V5. Incorrect behavior with an empty workspace If no tab is open in the workspace of Freelance Engineering.RN_2016_016). (#24475 .RN_2016_006). Downgrade der AC 900F / AC 900F Lite Firmware If a firmware version lower than Freelance 2016 is to be loaded into an AC 900F or AC 900F Lite controller with activated Control Net redundancy. the following errors were observed: 18 2PAA103593R0901 . select an item in the project tree and the buttons will be enabled again. Selecting a check message by double-clicking or with the Current error button will not open the corresponding object or program. keep always at least one tab open instead. A possible reason may be that the memory for variables via process image is too low. The process is still running in the background and can be detected via 2PAA103593R0901 19 .Section 3 Known Problems and Workarounds • • Freelance Engineering Switching between the operation modes configuration and commissioning is possible only once. If buttons are disabled. you have to scroll to have all functions available. Progress windows could disappear In some rare cases it might happen that progress windows disappear from Freelance Engineering when an import or export of large projects or a plausibility check of the same is done.RN_20131_004) Workaround: Do not work with an empty workspace. in some rare cases the variable list will be shown empty. then the corresponding menu items and buttons are disabled. The reason for this behavior is a failure during the import of filters for the variable list. (# 23815 . In some cases the complete functionality is reachable in full screen mode only. the unspecific message “Compiler limit reached” is displayed.RN_2013_013) Workaround: Reduce the amount of variables to be written via the process image. Message “Compiler limit reached” If an unexpected memory or data base problem occurs while checking the project. (#23276 .RN_2013_011) Workaround: Press the toolbar button Clear current filter.RN_2013_009) Variable list empty After the import of a project. Use Freelance Engineering in full screen mode If Freelance Engineering is used in a window instead of full screen mode. (#22090 . (#22507 . the “Check” function will not create new code and does not request loading the changes.[0 .RN_2013_046) Usage of 2 Ethernet modules within a non-redundant AC 800F If two Ethernet modules will be used in slots E1 and E2 of a non-redundant AC 800F. always use the “Check all” function to create new function code that can be loaded into the gateway station. or activate or deactivate external timeserver functionality. If the import/export or plausibility check is finished. for E1 an IP address within the range of 172. changing the gateway type. take care that an IP address out of various subnets is assigned to each Ethernet interface.[16 .255] and for E2 an IP address within the range of 172.31].[0 . During this time. Gateway Station Change of configuration does not affect project Changing the configuration of a gateway station in the project tree. It is recommended to set e. Thus.[0 15]. (#23049 . Freelance Engineering cannot be operated and seems to be blocked for the user.g.16.Freelance Engineering Section 3 Known Problems and Workarounds the Windows task manager. for example. does not lead to a red project node. 20 2PAA103593R0901 . (#22233 RN_2013_012) Workaround: After a configuration change of a gateway station. This behavior depends on the hardware of the PC and was observed mainly on fast multi-core machines.255] (#24482 .RN_2016_012).16. the progress window will come back to the front of the screen. CPU load reserve During operation a process station should have enough CPU load reserve for communication and irregular actions.RN_2013_043) Workaround: Change to another program and back to enforce a display refresh or add the variable into the value window to see the correct value. always use the corresponding dialog of the module. a value is shown with its configuration value instead of the current value. Therefore. (#23435 . an inconsistent display of current values were observed in commissioning mode of an FBD or ladder program. but shown in Freelance Engineering as written. but often refers to a gateway station.RN_2013_014) Workaround: Do not use the parameter upload dialog for correcting force and substitute values. We recommend to use the process stations with a CPU load not higher than 80%.Section 3 Known Problems and Workarounds Commissioning and Fieldbusses Commissioning and Fieldbusses General Correction of force and substitute values If a force or substitute value is corrected via the dialog “Parameter upload”. for example alarm bursts. Display of current values not consistent In some rare cases. the station has been stopped! Do you want to start it again?”. This message does not necessarily mean that the process station has been stopped. which was loaded along with the process station. in some cases the new value will be corrected correctly in the controller. (#23721 RN_2013_047) Error message after loading a process station After loading a configuration change to a process station an error message may be displayed: "Load operation of object xx failed due to error: 10001807. Because some connection lines may be not read correctly. 2PAA103593R0901 21 . (#23221 . If no OPC-related data has been modified. 22 2PAA103593R0901 .RN_2016_010). This also happens if the STC diagnostic message will be configured in Freelance 2016 at DA 701F which was previously applied in Freelance 2013 or 2013 SP1 (#24701 . Insert new DA 701F modules on the empty slots at the PM 783F and configure the newly created modules.cyclic error messages If the STC diagnostic message has been configured using the I/O editor in Freelance 2013 or 2013 SP1 for a DA 701F I/O module directly connected to the PM 783F. A pending update of an image is given priority. (# 23748 . all resources in the project can be manually loaded individually.RN_20131_009) Workaround1: Start a new load on the gateway station directly from the project tree. errors will be entered cyclically into the controller's event history. This modification is post-loaded automatically from Freelance Engineering. following a configuration change to and subsequent loading of a process station. Workaround2: Contact your local ABB service organization to turn off the automatic loading of version information to the gateway stations.Commissioning and Fieldbusses Section 3 Known Problems and Workarounds Technical background: Excerpt from the manual Freelance OPC-Server: “In general.” Loading on a gateway station is synchronized with pending data requests of the connected OPC clients. At the primary controller press the "TOGGLE" button and force a redundancy switchover 2. so that the charging process is rejected and the message described above is shown. the OPC server must also be loaded. Workaround: Delete all DA 701F modules which are configured at the PM 783F. Replace or deactivate CAN Module CI 910F If you want to replace or deactivate the CI 910F module of the primary controller. execute the following steps: 1. then only the project version number needs to be updated. PM 783F with DA 701F . Check for successfully redundancy switchover. After this. communication issues may occur by using high communication speed. Replace CI 910F and activate again. send and receive or Sartorius scale functions are used for AC 700F and AC 900F. The plausibility check reports an error if telecontrol. (#24704 . loading these function blocks leads to a crash of these controllers. (#15417 RN_2013_015) Temporary data loss during redundancy toggle possible A redundant process station works as the master for fieldbus communication. (#22058 . (#23260 . The Protronic function blocks must not be loaded to AC 700F and AC 900F. If a transmit command is overlaid by a redundancy toggle. This issue was observed by using 38 kBaud. the edges of the signals are different and may not be interpreted correctly.RN_2016_017) Fieldbus Communication Station type AC 700F and AC 900F The following functions are not released to be used with the station types AC 900F and AC 700F: • TCP variant of Ethernet Send and Receive function blocks • Sartorius Scale coupling • Protronic coupling These function blocks can be used within the configuration.RN_2013_026) The Protronic function blocks can be configured and checked for AC 700F and AC 900F without an error message.RN_2013_036) 2PAA103593R0901 23 . for example Modbus or Telecontrol. Now you can deactivate the CI 910F at the controller (formerly primary) 4.RN_2013_016) Communication issues with 38 kBaud on serial interfaces Depending on the used devices.Section 3 Known Problems and Workarounds Commissioning and Fieldbusses 3. a loss of these particular process values is possible. Due to differences in the used hardware chips. depending on the timing of the process station. (#23131 . RN_2013_017. (#24513 . It leads to an error message and the complete PROFIBUS slave will be deleted in the hardware manager. #22713 . line A) from the backup PROFIBUS master In this case. This operation is not restricted by Freelance Engineering.RN_2016_014) Workaround: Configure the station address of the backup PROFIBUS master to larger then 10.Commissioning and Fieldbusses Section 3 Known Problems and Workarounds Workaround: Reduce the communication speed.RN_2016_002) Restrictions for PROFIBUS If a third PROFIBUS master should be connected to a PROFIBUS net with 93.75 kBaud. the PROFIBUS address of this master must be lower than 60. (#23930 . PROFIBUS Failure in PROFIBUS communication with CI 930F Under the following circumstances the CI 930F can run into a PROFIBUS communication failure: • • • • Controller redundancy with PROFIBUS master redundancy is used PROFIBUS line redundancy is enabled Two or more redundant PROFIBUS slaves with a large number of input data (> 144 bytes and Tslot = 300 tbit) are used Disconnect one PROFIBUS line (e.75 kBaud.RN_2013_044) 24 2PAA103593R0901 . PROFIBUS slave will be deleted when moving I/O modules between S900 and S800 In the hardware manager it is possible to move I/O modules between an S900 DTM slave and an S800 DTM slave or vice versa via drag & drop. you must not use more than 80 PROFIBUS nodes.g. Using a PROFIBUS communication speed of 93. (#23378 . the PROFIBUS communication gets faulty until the unplugged line is reconnected to the backup PROFIBUS master. The reason for this is a faulty configuration of the address range in the module CI 930F.Section 3 Known Problems and Workarounds Commissioning and Fieldbusses Redundant PROFIBUS line reports failure After a communication break or a redundancy toggle. Example: Basic address on device is set to 3. an incorrect address or an unexpected answer NACK (not acknowledged). The probability is much higher when more than about 500 telecontrol items will be communicated. Increased CPU load in AC 900F by adding telecontrol function blocks Depending on the internal assignment of the telecontrol data. 2PAA103593R0901 25 . the communication may be disturbed permanently. Make sure that the address range includes all addresses of the PROFIBUS slave devices. (#21033 . If the outstation is also unable to handle the sent back telegram. configure minimum range from 3 to 67. this package may be mis-interpreted and sent back to the sender. the basic addresses and the redundancy offset addresses. although the communication is still running. the CPU load may increase considerably during telecontrol communication. slave redundancy offset is 64.RN_2013_022) Workaround: Correct the configuration of the telecontrol interface. (#23462 . a redundant PROFIBUSPROFIBUS line may report an error. (#23483 . a short-circuit between lines A and B will not always be detected.RN_2013_020) Telecontrol IEC 60870-5-101 / 104 Received packages are not handled correctly If in a Freelance system a telecontrol message is received which contains a not supported data type.RN_2013_019) Workaround: Check the configuration of the address ranges in all CI 930F modules. Short-circuit of redundant PROFIBUS line not detected If a redundant PROFIBUS line is operated with 12 MBaud.RN_2013_024) Workaround: Reduce the amount of telecontrol data in the related controller and ensure that the CPU load of the controller does not exceed 80%. (#23555 . Telecontrol IEC 60870-5-101 / 104 . (#22000 . (#23240 . This will lead to an error. FWK_DEV_M. The interface module FWK_DEV_M is only available in demo mode for testing purposes. thus the timeout is sent with a speed double than configured. Setting the flag "Use daylight saving time" has no affect to the time synchronization messages (#24655 . (#23224 . (#24703 .Restrictions Freelance 2016 supports only point-to-point-connections via the serial RS-232 interface.RN_2013_027) Wrong timeout value transmitted In some rare cases it was observed that a command value instead of a timeout value is transmitted.RN_2013_028) 26 2PAA103593R0901 . the process station must be restarted. Freelance Engineering shows that the change can be loaded into the controller by using “Load / Changed objects”.RN_2013_025) Time synchronization messages Time synchronization messages are always sent with system time (GMT). the configuration of the interface function block (FWK_DEV_TCP.Commissioning and Fieldbusses Section 3 Known Problems and Workarounds Modify the interface function block In a running project with telecontrol communication.RN_2016_015) Send and Receive Function Blocks Connection timeout The connection timeout is configured with the send function block in Freelance Engineering.RN_2016_003). UDP connection is a non-reliable connection. FWK_DEV. after this the change can be loaded. FWK_DEV_SL) is modified. SR_RNDEV and load via “Load changed objects”. These issues might occur with changes as follows: • • Change parameters of Ethernet Send and Receive function blocks SR_USEND. the timeout value will be communicated correctly again. • Press the Stop button to stop the task. this may result in unforeseeable system behavior. select the task with the Send and Receive function blocks configured. SR_TCP. SR_SNDEV. (#24394 . a Load whole station operation has to be performed.RN_2016_013). it may happen that the website will not be updated temporarily. • Repeatedly execute the task by clicking the Execute once button in the task bar.Section 3 Known Problems and Workarounds Process Stations Workaround: In commissioning mode of Freelance Engineering. SR_URECV.RN_2016_007). (#24371 . Process Stations Control Net Redundancy Contrary to the documented behavior.RN_2016_001) 2PAA103593R0901 27 . the failure of both Control Net lines in the primary controller does not cause a redundancy toggle if Control Net line A in the secondary has also failed (24490 . Delete an instance of the above-mentioned function blocks Workaround: After configuration changes of Send and Receive function blocks mentioned above. Loading configuration changes to a Send and Receive function block with active communication may lead to data inconsistencies in the controller If Ethernet send and receive configurations are changed and loaded into the controller. AC 800F Website When the website of the AC 800F controller is opened from multiple PCs. • Restart the task. (#21665 RN_2013_033) Area button "No area" in message line of Freelance Operations shows too many messages All messages of those tags which have not been assigned to a specific plant area are assigned to the area "No area". The modifications are loaded to Freelance Operations. and no data are shown in the Control Aspect dialogs. The area button "No area" in the message line of Freelance Operations should show the sum of these mentioned messages only. You have to press the ALT+TAB keys then to bring the DTM dialog to the front again. but additionally shows all system messages as well. (#24454 . the new IP address is configured in the wizard of the Control Aspect. at least two seconds should be wait before a new redundancy switchover will be triggered again (#24687 .RN_2016_009) Control Aspect No data in Control Aspect In a running project the IP address of the OPC server which is used by the Control Aspect for reading data is changed. No error is reported. Freelance Operations is brought to the front again.Freelance Operations Section 3 Known Problems and Workarounds Cyclic redundancy switchover If a redundancy switchover is initiated by user (toggle button or function block). Freelance Operations General DTM running in the background of Freelance Operations Some DTMs use a separate window for the user interface.RN_2016_004). (#23390 .RN_2013_035) 28 2PAA103593R0901 . but Control Aspect cannot establish the communication. For each new alarm message. Program list and Program.RN_2013_039) Workaround: Make sure that the names of all objects which are to be exported to BDM are unique. This is allowed in Freelance Engineering for different hierarchical elements like Task. (#21561 . This problem occurs if identical names are used for different elements in the project tree. Microsoft Excel does not support identical names for different sheets. no automatic change has been done. Bulk Data Manager Project Export to BDM Error message during project export During the export of a Freelance project to the Bulk Data Manager.Section 3 Known Problems and Workarounds Bulk Data Manager Workaround: The reason for this behavior is that in the DCOM settings the old IP address is still set. different Excel sheets are created for the selected objects of the project tree. Reopening will cause any changes you made to be discarded. During the export.xls is already open.xls?" Depending on the user action the export will be stopped or continued incompletely. this message is shown several times: “<name>. Please check the DCOM settings and modify them accordingly. Do you want to reopen <name>. 2PAA103593R0901 29 . Bulk Data Manager 30 Section 3 Known Problems and Workarounds 2PAA103593R0901 . and TC1. 2PAA103593R0901 31 . RU2. TC3 etc.) for each RollUp and TC. System Requirements (Operating System) All software packages of Freelance 2016 have been tested and released for use with the operating systems • Microsoft Windows 7 Professional and Enterprise SP1. Freelance Installation. Once you have installed your system as described in the Getting Started manual. Please install first the RollUps and then the TCs. each in ascending order. There is a subfolder (RU1. Please open the RollUP&TC folder at the top folder level on your software CD. For more information on compatible and released additional software programs and 3rd party software please refer to the manual Getting Started. Prior to starting the installation procedure of these programs. it may be required to install additional RollUps and Temporary Corrections TC. if two or more are available. accordingly prepare the PCs by loading the appropriate Windows operating system and making the necessary system settings. 32 bit and 64 bit. General Notes. RollUps and TCs provide important correction functions for errors that have been discovered after the product release and corrections that were not available at that point of time.Section 4 Installation System Requirements (Operating System) Section 4 Installation Use the CD delivered with the product to install the Freelance software. Installation of the Software Follow the installation instructions in the manual Getting Started. Each subfolder contains a Release Note file with installation instructions and short descriptions of the fixed errors. If a change for several versions (for example.2 kBit/s. For details refer to manual Getting Started. Make sure that all your project data are saved before starting the new installation.4013.1.4013). Please follow the instructions given there. Upgrade an existing version to the new version. When connecting a radio clock ensure that the transmission rate of the radio clock and the controller match (see M&I AC 900F and M&I AC 700F). For the up-to-date tested DAT files and Virus Definition Files refer to the document 2PAA149834 “Freelance daily verification of McAfee & Symantec updates” available in the ABB Library. Setups Starting the Setup Procedure The setup of Freelance software can be started from the CD using the autoplay program <Directory>:\AutoPlay. from Freelance 2013 to Freelance 2016). from Freelance V9 to Freelance 2016) is required.exe 32 2PAA103593R0901 . The Getting Started manual contains additional information about the usage of virus scanners. VirusScan Enterprise® (Version 8.g. Antivirus program The Freelance software has been tested with the antivirus program McAfee.8 Patch4) and Symantec Endpoint Protection® (12.Project Upgrade Section 4 Installation Project Upgrade Upgrading means changing from one Freelance version to a newer version. The transmission rate of the AC 700F and AC 900F diagnostic interface was changed to 19. please contact the ABB Service Department or your local ABB Representative for details and support. existing project configurations can be taken over without any problems if the upgrade is to the next higher revision level (e. In this process. This document replaces the document 2PAA108235. choose the components you want to install.com/contacts/ 2PAA103593R0901 33 . SetupMain. please contact your local service organization or your local ABB Representative for Control Products.Section 4 Installation Service Hotline After selection of the language.abb.png Service Hotline For technical assistance. http://www. Service Hotline 34 Section 4 Installation 2PAA103593R0901 . 01. 02.31 Processor Module 01.02.00 1.00.24 OS: 10. A3. A5.31 TD 951F 3BDH001020 R0001 Display unit for AC 900F 02. A6. OS: 10. 06.24.00.31 AC 900F 3BDH001000 (PM 902F) R0005 eA CPU Module 05.05. 01.00 Start up: 2. 02. Hardware versions of CPU modules Hardwareversionen der CPU-Baugruppen Type Typ Order No Bestell-Nr Description Beschreibung HW Index Firmware Revision AC 900F 3BDH001000 (PM 902F) R0001 CPU Module 02.24 CPU Module including battery A1. Display 01/1.01. 1.08. OS: 10.00 Start up: 2. A2.09.24.07. B0 Start up: 2.15 A7.06. A4.00 1.02.10 AC 700F 3BDH000364 (PM 783F) R0001 (15) AC 800F 3BDH000002 (PM 802F) R1 2PAA103593R0901 Version 10.Appendix A Compatible Hardware Versions CPU modules / CPU-Baugruppen Table 1. 03.30 35 .00 Start up: 2.24.31 AC 900F 3BDH001001 (PM 901F) R0005 eA CPU Module 06. 01. OS: 10. 01.24 TD 951F eA 3BDH001020 R0005 Display unit for AC 900F 05. 01. 17. 30. 30.02 Version 10.00. 12. 12. 11.16.08. 12. 12. 09. 30. 02.33. 30.32.02(1).06.30. 30.00.04.10. 02. 30. 30.01. 12. 40.01.35.02.02 12.03.02. 12.00 Version 10. 30.03.03(1).00.CPU modules / CPU-Baugruppen Appendix A Compatible Hardware Versions Table 1. 09. 09. 12.01.07.01 Version 10.06.08. 04. 50.00. 02.06. 01.05. 40.00.04. Hardware versions of CPU modules Hardwareversionen der CPU-Baugruppen Type Typ Order No Bestell-Nr Description Beschreibung HW Index Firmware Revision AC 800F 3BDH000003 (PM 803F) R1 Processor Module Step 1 01. 12.37.00(1).30 AC 800F 3BDH000530 (PM 803F) R1 Processor Module Step 2 02.01.39. 12. 02.38.20.02. 50. 30. 02.05. 02. 02.01(1).07. 02. 10. 09.00.18.04(1). 52.00(1).00 Version 10. 50. 09. 03.03.04. 12. 08.34.03. 02. 12. 12. 50.12.36.01.00.05.31. 40.30 DCP 02 0369 654 CPU Module including battery holder not for redundancy 07.00.30 DCP 02 0369 654(2) CPU Module including battery holder not for redundancy 50.30 36 2PAA103593R0901 . 51. 50. 12. 02. 02. 50. 40.06. 04.03. 04. 40. 01. 30.Appendix A Compatible Hardware Versions CPU modules / CPU-Baugruppen Table 1. 04.05.03.00.06.08 Version 10.07.05.08. 01. 50.04.13. 04. 40. 30. 04. 40. 30. 04.30 0338 701(2) CPU Module including battery holder for redundancy 50. 01.01. 04.04.10.11.02.11. 40.02 Version 10.06. 04. 04.12. 04.01. 51.02. 40.30 2PAA103593R0901 37 . 04.01.00. 04.02. 40. 40.06. 50.01.03.07. 40.09.90 Version 10. 40. 50.01. 30. 30. 30.12. 40.03. 52.04. 04. 01.07. 30. Hardware versions of CPU modules Hardwareversionen der CPU-Baugruppen Type Typ Order No Bestell-Nr Description Beschreibung DCP 10 0338 701 DCP 10 HW Index Firmware Revision CPU Module including battery holder for redundancy 02. 30.00 Version 10. 50.14.08.04.00. 02. 01.05.00. 01.04.09. 40.10. 40.05.02.30 DFC 01 0369 529(8) Processor Module (Freelance Select)(13) 01. 40. 40.07.14.02.15.05. 51.01.09.00.03.01.08.02.30 DFC 02 0369528 Processor Module 01. 40. 40. 30. 04. 30. A2 1. A1. A1. A2. A3. A6 1. 4 AO AX 722F 3BDH000377 R0001 24 V DC Analog Input/Output Module 8 AI.11 A0.I/O modules / E/A-Baugruppen Appendix A Compatible Hardware Versions I/O modules / E/A-Baugruppen Table 2. A3.11 16 AI AI 731F 3BDH000385 R0001 24 V DC Analog Input Module 8 AI AO 723F 3BDH000384 R0001 24 V DC Analog Output Module 16 AO AX 721F 3BDH000370 R0001 24 V DC Analog Input/Output Module 4 AI. A6 1. 8 DI/DO 4 AI.11 A1. A4 1. A4 1. A4. A3. A2. Hardware versions of the I/O modules Hardwareversionen der E/A-Baugruppen Type Typ Order no Bestell-Nr Description Beschreibung AI 723F 3BDH000376 R0001 24 V DC Analog Input Module HW Index Firmware Revision A1. A5. A2.11 A1. A5. A4. A3. A3.11 A1. A2. 16 DI/DO 38 2PAA103593R0901 . A1.11 A0. 8 AO DA 701F 3BDH000371 R0001 24 V DC Digital/Analog Input/Output Module 16 DI. 4 AO DC 732F 3BDH000375 R0001 24 V DC Digital Input/Output Module 16 DI. A3 1. A2. A2.11 A0. A4 1. 02. FEA 4. 04.00.12.22 DAI 02 0369 630 Analog Input 16 x 0.. 16 x 0/4. 07.21.33. A1 1. 05. 04. 16 x 0/4.20.03. DEA 4.00. 4 DO relay contacts DAI 01 no Flash 0369 628 Analog Input 02. 04. DEA 4. Hardware versions of the I/O modules Hardwareversionen der E/A-Baugruppen Type Typ Order no Bestell-Nr Description Beschreibung DI 724F 3BDH000374 R0001 24 V DC Digital Input Module HW Index Firmware Revision A0. 06. 05.22. 30..11 A1. A3 1. DEA 3.11 A1.Appendix A Compatible Hardware Versions I/O modules / E/A-Baugruppen Table 2.02.36 2PAA103593R0901 39 .34. FEA 4. A2.10 V DC 03.37.01.. DEA 4.56(4).01.04 FEA 4. 06. 40. 30. 30.00. DEA 4. 40.20.00.02.34. FEA 4..03 DEA 3.03 DEA 3. A3 1. DEA 4. 06.56(4).00.00.01.01.19.01.11 32 DI DX 722F 3BDH000383 R0001 24 V DC Digital Input/Output Module 8 DI.00. 30.00.10 V DC 40.18.20 mA.20.19. 40..00. 40. Re 50 Ohms 06.. FEA 4. 30.10. 08. DEA 4. 05. DEA 4.00.00.37. DEA 4.03. 40.20 mA.01.00. 03.21. 30.02..01. 08. 40.01. DEA 4. DEA 4. 40. A2. 30. 03.18.00. 30. 8 DO relay contacts DX 731F 3BDH000387 R0001 230/120 V AC Digital Input/Output Module 8 DI. 40.36 DAI 02 no Flash 0369 630 Analog Input 16 x 0..10.00. DAI 01 0369 628 Analog Input 40.33. DEA 3. 08.04 Re 50 Ohms FEA 4.00. 06. 30. 40.02.05.04. FEA 4.20 mA 01.02. DEA 3.00. 01. DEA 4.00.10.22 DAO 01 0369 629 Analog Output 16 x 0/4.33.01.01. 03.04 D2A 1.04 FEA 4. 30.21. 30.19.03. FEA 4. 06.10.56(4).18. D2A 4. D2A 4.21. FEA 4.03 FEA 4.02 DEA 3. 30. DPT 4.33.04(4).01.02.19.07. FEA 4.03. 02.21.56(4). 30. 40.01. 05.18.00.10.10.33.. D2A 4. D2A 4. D2A 4. DPT 4.20 mA.04. 40.16. 30.00. DPT 4.. 02. 30. 40. 16 x 0/4.16. FEA 4. FEA 4.56(4). 30.33. 40.. DEA 4.20 mA 40.04 Re 250 Ohms DEA 3.36 DAI 03 0369 631 Analog Input 40. 30. 30. 40.08. thermo elements. DEA 4. 06. 30. DEA 4.02. 40. 30.33.06.01.36 DAO 01 no Flash 0369 629 Analog Output 16 x 0/4. DEA 4.03.36 DAI 04 0369 632 Analog Input 8 x Pt100.34. DEA 3.20. 40.20. DPT 4.34. DEA 4.01.36 40 HW Index Firmware Revision 2PAA103593R0901 . 30. Re 250 Ohms 06. 40. FEA 4.00.34.36. D2A 4. 06. 30. 30.. FEA 4.22.37. 16 x 0/4.12.00.03.00. 30.02. 09.00.01.14.20 mA. FEA 4. 40.00.04(4). 30.00(6).20.01.36 DDI 01 no Flash 0369 626 Digital Input 32 x 24 V DC 02.00. DEA 4. DEA 4. 30.02. 16 bit 04.01.01(6) DAI 05 0336 025 Analog Input 16 x 0/4. 05. FEA 4.15(5). 30. DPT 2.33.01. 04. DEA 4.21.03.00.30.02.09 DPT 2. 30. DPT 09..31. 01.20 mA 02.19. 06.00.22 DDI 01 0369 626 Digital Input (Flash) 32 x 24 V DC 40. DEA 4. DEA 4.31.03 DEA 3. 40. DEA 4.. DPT 4.01. 30..05. DEA 4. 30.37. 30. DEA 4.20. DEA 4..00. 40.02.00.18. 30.01. 30.00.00.I/O modules / E/A-Baugruppen Appendix A Compatible Hardware Versions Table 2. 40. 02.06 FEA4. mV sensors. Hardware versions of the I/O modules Hardwareversionen der E/A-Baugruppen Type Typ Order no Bestell-Nr Description Beschreibung DAI 03 no Flash 0369 631 Analog Input 03..12. 40. 30.34.. DPT 09.00. 40.. FEA 4.09.33.06(4). DIO 4. 03..00. DIO 4.00. D2A 4.34.00.36 DDO 01 no Flash 0369 627 Digital Output 02. 30.230 V 40. DIO 4.02 DIO 1.00.60 V AC/DC 40.00. DIO 4.00.00.02 DIO 1.21.36 DDI 03 no Flash 0369 638 Digital Input 16 x 115. 40.. 30. DIO 4.56(4). 30.33. Hardware versions of the I/O modules Hardwareversionen der E/A-Baugruppen Type Typ Order no Bestell-Nr Description Beschreibung DDI 02 no Flash 0369 637 DDI 02 HW Index Firmware Revision Digital Input 16 x 24.16. 04.. DEA 4.22 DDI 03 0369 638 Digital Input (Flash) 16 x 115. 0. DIO 4.01. D2A 4..31.01.10.18.01. 06.21. 04.06(4). 30. DEA 4.36 DDI 05 0369 640 Digital Input (Flash) 32 x 120/230 V AC 40. DIO 4.33. 07. A 06.10.Appendix A Compatible Hardware Versions I/O modules / E/A-Baugruppen Table 2. 30. 30. 30.36 DDI 04 0369 639 Digital Input (Flash) 28 x NAMUR sensor inputs. DEA 4. 05.5 05..00.00. FEA 4. 04. DIO 4. 07.00. 30.22 41 .09.00.10 2PAA103593R0901 DEA 3.00.10. 32 x 24 V DC.01 FIO 4. or 12 x 3. or 28 x contacts.01.00. or 12 x changeover contacts. 04. 04.00.01 FIO 4.22 0369 637 Digital Input (Flash) 16 x 24.19. FIO 4. FIO 4.03.01.02.230 V AC 03. 30.21. DEA 4.02 FEA 4.04. D2A 4. 30.06 D2A 4.10.33.05. 07.60 V AC/DC 03.. 40..01.or 4wire sensors 30. 40.33.09. 16 x 24.I/O modules / E/A-Baugruppen Appendix A Compatible Hardware Versions Table 2. FIO 4. 5 A.60 V AC/DC. 30.00.02. DIO 4. DIO 4. 0. DIO 4. 40. DIO 4.01.00.10.03 FIO 4.01. DIO 4.00. DIO 4.10. 40. relay with readback 03.01. 04.01..22 DDO 02 0369 642 Digital Output 40. D2A 4.33. 5 A.00.02. 04... D2A 4.00. 03.09. DIO 4.01.00. 30...33. 40.10.36 DDO 03 no Flash 0369 643 Digital Output 16 x 24.06(4).22.10. DIO 4.00.. 30.00 D2A 1.00. 42. 30.03. 30.03 AC/DC. 5 A. DDO 04 0369 644 Digital Output 16 x 115. DIO 4.36 42 2PAA103593R0901 .05. 40.00..02. 5 A.00. 40. 04. 30.5 30. 40.36 DDO 02 no Flash 0369 642 Digital Output 03.21.230 V AC. D2A 4.10.20.02 DIO 1.00.06(4).36 DDO 04 no Flash 0369 644 Digital Output 16 x 115.04(4).230 V 40.00.10. FIO 4.00.00.03 FIO 4. 04.02.01. relay with readback 03.31. DIO 4. relay with readback 40.09. Hardware versions of the I/O modules Hardwareversionen der E/A-Baugruppen Type Typ Order no Bestell-Nr Description Beschreibung HW Index Firmware Revision DDO 01_2 0369 627 Digital Output 10. 40.02 DIO 1.01.. relay DIO 1.00. 40..230 V 30.60 V AC/DC. 30. 30.14. DIO 4. A 40.230 V AC.16. 40.22 DDO 03 0369 643 Digital Output 16 x 24. D2A 4.01. DIO 4. D2A 4.21.12.. D2A 4. 5 A. relay FIO 4. 20. 16 x 24. DIO 4. 40.06(4).. 40. relay with readback 40. FIO 4..04. 32 x 24 V DC. 40. 5 A. 30.02 AC/DC.33.21. 02.11.06 DFI 4. 30. 30. DLM 4.04. 40. 30. 40. plus 2 digital inputs and 2 digital outputs 30. 30.22.06. Hardware versions of the I/O modules Hardwareversionen der E/A-Baugruppen Type Typ Order no Bestell-Nr Description Beschreibung DFI 01 0369 681 DLM 01 DLM 02 HW Index Firmware Revision Frequency Input 4 frequency inputs.04.00.14. 05.00. 01. FLM 4.01. 40. FLM 4. 40. 30. 30.00. 40.03.35.33.01.12.15.31. 30. 40. 30.00. 30. 30. 30.03.04.02. to connect 2 power supplies 01.05.01.05.03. 30.01. DFI4.06. 30.05. 05. 30.05. 40. 40. DLM 4. 30. 30.02. 30. 40.02. 40. 40.01. DFI 4.04.02.03.00. 40. 01. 30.00.00.05 DLM 4.34.02.00.21.36 2PAA103593R0901 43 . 30.Appendix A Compatible Hardware Versions I/O modules / E/A-Baugruppen Table 2.30(7).04. DFI 4.03. FLM 4. DFI4.01.36 374210369652 Link Module including battery holder for one power supply 03.32. 05.10. 30. 40. DLM 4. 04.06 no Firmware 0338 434 Link Module including battery holder for power supply redundancy. 30 CI 930F (2 SUB-D) eA 3BDH001010 R0005 Fieldbus Interface Module PROFIBUS 05.02. 01.Fieldbus modules / Feldbus-Baugruppen Appendix A Compatible Hardware Versions Fieldbus modules / Feldbus-Baugruppen Table 3.04 3BDH001010 R0001 Fieldbus Interface Module PROFIBUS 02. 01. 02. 01.01 1.30 CM 772F 3BDH000368 R0001 Fieldbus Interface Module PROFIBUS A1.05 44 2PAA103593R0901 .92 FI 810F 3BDH000030 R1 Fieldbus Interface Module CAN (triple channel) 01.03. 01. RJ-45) HW Index Firmware Revision Fieldbus Interface Module CAN (triple channel) 05.04 FI 820F 3BDH000031 R1 Fieldbus Interface Module Modbus.00 1. Serial (dual channel) 01.00 1.00 1.03.00.04.210 TU 951F 3BDH001035 R0001 PROFIBUS Terminal for Line B 00.30 CI 773F eA 3BDH000395 R0005 Fieldbus Interface Module PROFIBUS 05. Hardware versions of the Fieldbus modules Hardwareversionen der Feldbus-Baugruppen Type Typ Oder no Bestell-Nr Description Beschreibung CI 910F 3BDH001005 R0005 CI 930F (SUB-D. A2 V1. 01.04.01. 02.00. 01.R.02.00.24R00 DFM 02 0369 571 Fieldbus Interface Module Modbus.08.03.04.00 2PAA103593R0901 45 . 03. 04.01 5.00. 02.24.03.03. 03.03.00.01.00.Appendix A Compatible Hardware Versions Fieldbus modules / Feldbus-Baugruppen Table 3. 02. 03. 02. 01.00. Serial (dual channel) 01. 02. 02.02. 02.00 FI 840F(14) 3BDH000033 R1 Fieldbus Interface Module Foundation Fieldbus 01.00.01.01.02. 02.02. 01. Hardware versions of the Fieldbus modules Hardwareversionen der Feldbus-Baugruppen Type Typ Oder no Bestell-Nr Description Beschreibung FI 830F 3BDH000032 R1 HW Index Firmware Revision Fieldbus Interface Module PROFIBUS-DP 02.02.01. 04.01.03. 03. 01.04. 4.01 4.05 DFM 03 0369 572 Fieldbus Interface Module CAN (triple channel) 01.03.00. 01.02. 04. 01. 03. 01. 02. 03. 02. 03.03. 03.00.04. 03. 01.02. 03.02.09 DFM 01 0369 570 Fieldbus Interface Module PROFIBUS-DP 01.04. 01. 04. 02. 01. 4. 03.01.01.01 5.04. 01.02. 03. 03.03.04 DFM 11 0369 575 Fieldbus Interface Module Select PROFIBUS-DP Select 02.02. 04. 1. 01.00.00(10)(11).00.01 DFE 02(12) 0369 566 Ethernet Interface Module 10MBit AUI 01. 03.06.08. 2.00. 04. 04. 03. 01.00. 04.06. 02.02. 03.01. 04. 04.00.00. 01.03.05.00(10)(11).00. 01.00(10)(11). 02. 04.03.03. 03.03.05. 1.00.01. 03.Ethernet modules / Ethernet-Baugruppen Appendix A Compatible Hardware Versions Ethernet modules / Ethernet-Baugruppen Table 4. 03.01.01 EI 801F 3BDH000015 R1 Ethernet Interface Module 10MBit 10Base2 02. 04.04. 01. 03. 02. 03.02. 02.02.03(10)(11).01 DFE 03(12) 0369 567 Ethernet Interface Module 10MBit 10BaseT 01. 01. 01.04. 01. 03.00. 04.01.01. 03. 04. 03.03.02. 2. 02.01(10)(11) EI 811F 3BDH000020 R1 Ethernet Interface Module 10MBit 10Base2 (for PM 803F) 01. 01. 02.01.01.00. Hardware versions of the Ethernet modules Hardwareversionen der Ethernet-Baugruppen Type Typ Oder no Bestell-Nr Description Beschreibung HW Index DFE 01(12) 0369 565 Ethernet Interface Module 10MBit 10Base2 01. 04.01.03(10)(11).00. 04.07.01(10)(11) EI 802F 3BDH000016 R1 Ethernet Interface Module 10MBit AUI 01.01(10)(11) EI 803F 3BDH000017 R1 Ethernet Interface Module 10MBit 10BaseT 03. 01.00.04(10)(11). 04. 2. 02.04.01. 01.01. 03.07. 02. 02.00. 01.00.03(10)(11).01 46 2PAA103593R0901 .02(10)(11). 01. 04. 04. 01.08.90(10)(11). 03. 03. 30.00. 03. 04.00. Hardware versions of the Ethernet modules Hardwareversionen der Ethernet-Baugruppen Type Typ Oder no Bestell-Nr Description Beschreibung EI 812F 3BDH000021 R1 Ethernet Interface Module 10MBit AUI (for PM 803F) 01.03. 01. 02. 03. 31. 03.04.02.00. 04.02.00.01. 03. 05.01 HW Index Communication modules / Kommunikations-Baugruppen Table 5. 03.00. 02.02.00.03.01 5.01.01 EI 813F 3BDH000022 R1 Ethernet Interface Module 10MBit 10BaseT (for PM 803F) 01. 1 x RS232C for diagnosis Modbus Master/Slave HW Index Firmware Revision 02.14 47 .03.01.01. 02.00.04.00. 02.01. 01. 30. 04.Appendix A Compatible Hardware Versions Communication modules / Kommunikations- Table 4. Hardware versions of the Communication modules Hardwareversionen der Kommunikations-Baugruppen Type Typ Oder no Description Bestell-Nr Beschreibung DCO 01 0369 666 2PAA103593R0901 Communication Module 4 x RS232C/RS422/RS485. 31. 02. 02.03. 02.00.01.00.01.00.01.02. 04. 02.01. 30. 03.01. 03. 03. 04. 30. 02.02. 05. 01.02.01. 02.03.00.01.03.00 SD 802F 3BDH000012R1 Power Supply Module (24 V DC -> 24 V DC) 01.00.01 DFP 01 Select (DFP 11) 0369 562 Power Supply Module Select (115/230V AC -> 24 V DC) 01. 02. 02.04. 04. 03.00.00. 02. 01.01.00.00 AM 811F 3BDH000050R1 Battery Module 01. 01. 02. 01.03. 01. 02. 02.04. 04.00.01. 04.00.00. 02.01 DFP 02 0369 560 Power Supply Module (24 V DC -> 24 V DC) 01. 01. 05.01. 01.00. 02. 02. 01. 01.00.00 SA 811F 3BDH000013R1 Power Supply Module (for PM 803F) (115/230V AC -> 24 V DC) 01. 01. 02.01. 02.01 48 HW Index 2PAA103593R0901 .01.00. 02.00.01. 02.00 DFA 01 0369 557 Battery Module 01. 02.00.02.00. 03.00 SD 812F 3BDH000014R1 Power Supply Module (for PM 803F) (24 V DC -> 24 V DC) 01. 04. 02. 02. 01. 02. 02.00. 04.02.01.00.03.02.02.01.03. Hardware versions of the Power supplies Hardwareversionen der Spannungsversorgungen Type Typ Oder no Bestell-Nr Description Beschreibung AM 801F 3BDH000040R1 Battery Module 02. 05. 02.Power supplies / Spannungsversorgungen Appendix A Compatible Hardware Versions Power supplies / Spannungsversorgungen Table 6. 01. 04.01.00 SA 801F 3BDH000011R1 Power Supply Module (115/230V AC -> 24 V DC) 01.01. 03. 03. 05.00 DFP 01 0369 561 Power Supply Module (115/230V AC -> 24 V DC) 01.01.90.01.02.03.00. 02. 11 A1. A3. A3. A1. A2. A1. A2. A4 1. A6 1. A3 1.11 A2. Thermo element 8 AI AO 723F 3BDH000384 R0001 24 V DC Analog Output Module 16 AO AX 721F 3BDH000370 R0001 24 V DC Analog Input/Output Module 4 AI. A3. A2. A3. Hardware versions of the S700 components Hardwareversionen der S700-Komponenten Type Typ Oder no Bestell-Nr Description Beschreibung AC 722F 3BDH000369 R0001 24 V DC Analog Input/Output Module HW Index Firmware Revision A0.11 A0. 4 AO AX 722F 3BDH000377 R0001 24 V DC Analog Input/Output Module 8 AI. A3. A4. A4 1. A5. 8 AO 2PAA103593R0901 49 . A6 1. A1.11 A0. A2.11 8 AI/AO AI 723F 3BDH000376 R0001 24 V DC Analog Input Module 16 AI AI 731F 3BDH000385 R0001 24 v DC Analog Input incl.11 A1. A5. A2. A4. A4 1.Appendix A Compatible Hardware Versions S700 PROFIBUS-slave components / Komponenten S700 PROFIBUS-slave components / Komponenten des S700 PROFIBUSSlave Table 7. 11 A1. A3.11 A1.11 2 counter inputs. A3. A4 1. 4 AO DC 722F 3BDH000372 R0001 24 V DC Digital Input/Output Module 16 DI/DO DC 723F 3BDH000373 R0001 24 V DC Digital Input/Output Module 24 DI/DO DC 732F 3BDH000375 R0001 24 V DC Digital Input/Output Module 16 DI. A5 1. 8 DI/DO 4 AI. A4. Hardware versions of the S700 components Hardwareversionen der S700-Komponenten Type Typ Oder no Bestell-Nr Description Beschreibung CD 722F 3BDH000393 R0001 24 V DC Frequency Input Module HW Index Firmware Revision A2.S700 PROFIBUS-slave components / Komponenten des S700 PROFIBUS-Slave Appendix A Table 7. A1 1. 16 DI/DO DI 724F 3BDH000374 R0001 24 V DC Digital Input Module 32 DI 50 2PAA103593R0901 . A2 1.11 A0. A2 1. 2 DI 8 DI/DO DA 701F 3BDH000371 R0001 24 V DC Digital/Analog Input/Output Module 16 DI.11 A1. 2 DO. A2.11 A1. A2 1. 8 DO relay contacts DX 731F 3BDH000387 R0001 230/120 VAC Digital Input/Output Module 8 DI.01 the CPU modules DCP02 and DCP10 are redesigned. mixture use with newest V3 eproms is allowed 2PAA103593R0901 51 . 149 and 150 for details. A3 F (1) Not for plugging and unplugging with switched on power supply. Please refer to Technical Bulletins 136. that means: not for use with an redundant system. (4) Only at V2 compatibility mode.Appendix A Compatible Hardware Versions S700 PROFIBUS-slave components / Komponenten Table 7. A2. (3) There are some restrictions for several firmware versions and the corresponding hardware revisions. A1. Please contact the service organization for detailed information. A2. 4 DO relay contacts DC 705F 3BDH000388 R0001 FBP Interface Module PDP22FBP 1SAJ240100R Fieldbus Plug 10xx A0. Using this hardware it is mandatory to use specific software versions. (2) Starting with Hardware Index 50. A3 1. Hardware versions of the S700 components Hardwareversionen der S700-Komponenten Type Typ Oder no Bestell-Nr Description Beschreibung DX 722F 3BDH000383 R0001 24 V DC Digital Input/Output Module HW Index Firmware Revision A1. These restrictions cannot be displayed within this table.11 8 DI.11 A1. A3 1. A2. (10) Can be used in PM803F (16MB controller) also.00. (11) No battery backup with this version in PM803F (16MB controller).00 and DPT 9.S700 PROFIBUS-slave components / Komponenten des S700 PROFIBUS-Slave Appendix A (5) See hardware release note 102 ‘Eproms for I/O cards’. It is strongly recommended to update DPT 9. (12) Cannot be used within PM 803F (16MB controller). Afterwards the FieldController select can be loaded from Freelance Engineering. (7) DFI firmware revision 4. where ’XXX’ is the number of I/O that you need in your project. (13) After loading the new EPROM version in a FieldController select.1 including 1 x Control SW for XXX I/O.01 are only allowed with DAI 04 HW Index 30.07 or 09. (21899) (14) Starting with FI 840F hardware index 03.1 or higher for Control Builder F. this controller must be switched off for at least 2 minutes. 30. In addition you need to order the StepUp to V7. PROFIBUS with AC 700F is not supported with older versions of AC 700F CPU module.00 to DPT 9. Please use the I/O-Count software to determine how big an I/O license you need (contact your local sales representative).06.1 with a FieldController Select you need to order a StepUp to V7. During this time also the battery must the removed. note 2 (6) DPT 09. (15) For usage of the PROFIBUS functionality at least hardware version A3 of the CPU module must be used.22 has to been changed to the above revision (8) In order to use V7.01. 52 2PAA103593R0901 .00 again 4 FI 8540F modules can be used in one controller. Appendix A Compatible Hardware Versions Compatibility of PM 802F modules Compatibility of PM 802F modules For usage with the 16 MByte CPU module PM 803F newer Ethernet modules EI 811F. (11). EI 812F and EI 813F were developed and released. Some of the preexisting Ethernet modules can be used with the 16MByte CPU. see foot notes (10). DFE 02/EI 802F and DFE 03/EI 803F with the CPU module PM 803F there is no battery backup available for this station. (12) above. Using the modules DFE 01/EI 801F. 2PAA103593R0901 53 . Compatibility of PM 802F modules 54 Appendix A Compatible Hardware Versions 2PAA103593R0901 . . With regard to purchase orders.www. Copyright © 2015 ABB All Rights Reserved All rights to other trademarks reside with their respective owners.com/controlsystems www. The reproduction. We reserve all rights to this document and the items and images it contains. disclosure to third parties or the use of the content of this document – including parts thereof – are prohibited without ABB’s prior written permission.abb. Power and productivity for a better world TM 2PAA103593R0901 Contact us .abb.com/controlsystems Note: We reserve the right to make technical changes to the products or modify the contents of this document without prior notice.com/freelance www. the agreed particulars shall prevail. ABB does not assume any responsibility for any errors or incomplete information in this document.abb.
Copyright © 2024 DOKUMEN.SITE Inc.