RAJAMANE Full_Catalog_09.pdf

April 2, 2018 | Author: chidambaram kasi | Category: Pump, Coolant, Numerical Control, Viscosity, Engines


Comments



Description

RCE ISO 9001 : 2000 Certificate: 041009396 NORD COOLANT PUMPS FOR . . . Machining . . . Flooding Circulating Ink / Varnish Grinding Chip Conveyer Filtration . . . . . . High Pressure Cooling Through Tool Washing Filtration . . . Refrigeration/ Temperature Control . . . Printing Packing Welding . . . . . . Oil Skimming Belt Disc . . . Product Of Proven Performance USABLE NOTE : 2 POLLUTION / / / / / X / X X X X / X X X X / X X / X X X / X / .800 2 CASTED MEDIUM X CLOSED SOLVENTS X COARSE DE IONISED WATER X CHEMICALS WATER X EMULSIONS / WASHING / CIRCULATING / GRINDING X X X X X X X TURNING X X RV25…..5 TO 1 MM FEW < 0. 0250 X X X X X X X X X X X X / / X X X 11 RK 060 X X X X X X X X X X X X 12 RKM 0250. FEW RK275.5 X X X X X X X X / TYPE X SHEET METAL FABRICATED.500 X X X X X X / X X / / / X X X X X 5 RKM200 RKM300.PLEASE ASK BEFORE SELECTING POLLN.7.RKM400 X X X X / X / X X / / / / X X X 6 RKM100. LEVEL COARSE > 1MM MEDIUM 0. 050 X X / X X X / X X 13 RPP 14 RTH45 X X .RKM250 RMS400-800 X X X X X X X / X X / / / X X 7 RR50 X X X X X X X / X X / / / / X 8 RMB-V-50.250 MILLING X 1 SAWING BORING IMPELLER TYPE 30-40% 20% 10-20% PERIPHERAL POLLUTION MEDIUM CHILING HIGH TEMPERATURE APPLICATION COOLANT & LBRCTS SERIES SNo X X X . RMS400-800 X X X X X X / X X / / / X X X X X 4 RKC100….100 X X X X / X / X X / / / 9 RKM060 X X X X X X X X X X X X / / X 10 RMH 060.5….COOLANT PUMPS RECOMMENDATION CHART SEMI OPEN X X X X X X / X X / / / X X X X X 3 RK3.. .. HIGHLY EFFICIENT... EFFICIENT PUMPS FOR CNC HIGH PRESSURE APPLICATIONS. UPTO 1 MTR... 8 RK3. 17 RKM100 MOST POPULAR. FOR CNC MACHINING CENTRES 20 RMS400. FILTRATION SYSTEMS.. FOR GRINDING MACHINES. MEDIUM PRESSURE PUMPS FOR ALL CNC TURNING CENTRES & MACHINING CENTRES 18 RKM200 & 300 MULTISTAGE PUMPS FOR MACHINING CENTRES 19 RKM250 MOST RUGGED.COOLANT PUMPS CATALOG INDEX PAGE NO.. IMMERSION DEPTH 7 RK275.. HIGH PRESSURE & HIGH FLOW PUMPS FOR COOLANTS WITH CONTAMINATION. SINGLE STAGE & COUPLED TYPE PUMPS FOR FILTRATION APPLICATION. TECHNICAL INFORMTION 3 . 23 – GENERAL INFORMATION ON OUR OTHER PRODUCTS.. COOLANT EMULSIONS FOR CHILLERS / REFRIGIRATION / SPINDLE COOLING 13 RMH0250 HORIZONTAL PUMPS. GERMANY PUMP PORTION. TEMPERATURE CONTROL EQUIPMENTS 12 RKM0250 RKM050 MULTISTAGE. 22 RSB STIRRERS. FOR USE IN COOLANT TANKS AND SIMILAR APPLICATIONS. MULTISTAGE PUMPS WITH HIGHER CONTAMINATION HANDLING CAPACITY. RV250 RKC & RSM SINGLE STAGE COOLANT PUMPS FOR CONVENTIONAL MACHINES. FOR SPECIAL APPLICATIONS. THROUGH COOLANT APPLICATION 16 RMH060 HORIZONTAL.800 MULTISTAGE. COMPACT PUMPS FOR CLEAN LIQUIDS FOR WATER. 11 RR50 COMPACT. 9 RPP ALL POLY-PROPELENE PUMPS FOR SPECIAL APPLICATION 10 RMB-V TANK TOP MOUNTING TYPE. 21 ROS OIL SKIMMENS FOR REMOVAL OF FLOATING OIL FROM COOLANT TANKS.5. HIGH FLOW COOLANT PUMP.... IN COMPACT SIZES FOR CHILLER UNITS. 24 BRINKMANN PUMPS SPECIAL BRINKMANN PUMPS FOR MACHINE TOOLS INDUSTRY. LOW IMMERSION. COUPLED WITH RAJAMANE MOTORS FOR HIGH PRESSURE APPLICATIONS..IN CAT. 15 RTH45 BRINKMANN PUMPS. FOR CHILLERS / REFRIGIRATION / SPINDLE COOLING 14 RKM060 ALL STAINLESS STEEL PUMP PARTS. HIGH PRESSURE PUMPS FOR CNC LATHES. IMPORT SUBSTITUTE PUMPS FOR CNC MACHINES. COMPONENT WASHING. MODEL/SERIES SALIENT FEATURES (FOR DETAILED SELECTION CHART REFER RECOMMENDATION CHART) 4 5 – 6 RV25.800 SINGLE STAGE. ALL STAINLESS STEEL PUMP PARTS FOR SPECIAL APPLICATIONS.RK7 RKC & RSM BOTTOM OUTLET. 3 Phase. Self cooling motors (TESC) are fitted for coolant pumps with upto 0.:SHORT A1B1C1 SUPPLY A2B2C2 or HIGH VOLTAGE A1 B1 C1 A2 B2 C2 (colour coded) Single phase Motor : Star-delta connection-for 5. Dual voltage connection : LOW VOLTAGE A1 B1 C1 C2 A2 B2 FOR LOW VOLTG: SHORT A1C2. The motors are capable of taking this extra current. etc.C2 FOR HIGH VOLTG.O. CL-F/B. in addition to the ambient temperature (room temperature): Class of Insulation Temperature Raise B 80o C F 120o C 5. ELECTRICAL: 1. 6. Frequency Drive: Most of the motors are suitable for operating through frequency drive. based on its class of insulation. Always connect the 3 phase coolant pumps through suitable OLR or MPCB to avoid motor failures due to overloading. For overloading with 60 Hz. 4. remove shorting leads.5kw & above: U1 V1 W2 U 2 W1 U1 V1 A1M1 V1 For star/delta starter SUPPLY W1 For Direct online start CAP M2 For changing the direction.C1B2 SUPPLY A2. .415V. The power rating is given against the pump model. 7. single phasing .) 4 A2 . to avoid nuisance tripping caused by variation in loads. from 0-50 Hz. ask factory. For through starter. These motor body temperature raise have been tested & are within the range specified in class of insulation section. starting connect in delta.R COOLANT PUMPS Technical Information I. 3.L. for direct online start U V Dual speed-dhahlender winding: FOR LOW SPEED: W FOR HIGH SPEED: Supply SUPPLY OPEN SUPPLY SHORT A2B2C2 A1B1C1 A1B1C1 A2B2C2 TO CHANGE THE DIRECTION OF ROTATION INTERCHANGE ANY TWO SUPPLY LEADS. Connection diagrams: Standard 3 leads. S1 duty.2800 RPM. supply frequency.50Hz. voltages. insulation Class & frequency are available on request. All standard coolant pumps are fitted with Induction motors having specifications as.18kW rating.B2. OLR/MPCB setting: set the current in these at 10% higher than that on the nameplate. Other voltage. Temperature raise: All motor temperature raise is as under. 2. interchange M1 & M2 (For D. etc. The body temperature of these motors will be within 80O C even when felt very hot by bare hand.B1A2. voltage fluctuations. 25 0. 1. For detailed mounting ask factory. For best performance of the pumps. As such the standard motors can be used for liquids having 5 CST viscocity & coolant emulsions.etc.r. For higher on/off per hour applications. Pressure Boosting Arrangement: The following diagram shows. Side suction pumps for outside tank mounting: These pumps are available for series RKM0250. For grinding or similar application involving abbrassive dust in the coolant: It is recommended to use pumps without bush bearings for such applications.25 0.8 2 4 4.08 0.5 10. fittings having good radius at bends & elbows to avoid head losses. the raising specific gravity needs more power. e. Pipe fittings: Use always standard G.3 2.75 1.18 0. against their kW is given below. II. RKM050 .54 1.g.2 specific gravity liquid. 4. 5 . Effect of Viscocity & Specific Gravity of liquids: The raising viscocity needs more power. The schematic diagram is as under. 9. Do not fit an elbow or reducer nipple immediately at the pump outlet. For multistage coolant pumps.7 8 8. mention while ordering the pump. For any change.5 0. Balance portion of the pump can be mounted on a spacer like distance piece. Give any extensions given after frame / model like X. 12 OíCLOCK EXISTING PUMP 3 OíCLOCK BOOSTER PUMP 10.RKM200. For RR Series refer catalogue page 12.2 kw is recommended for 1. Take the same pipe as the outlet is as far as possible. to get the best flow/pressure at the end point of piping.9 1.6 4. 13. Use only parallel (G) threaded fittings with butting face. at room temperature only. Pump performance varies +/.3 9. on the nameplate. If the pump is fitted with special motor of other RPM. 5.5 1.XZ.4 3.R COOLANT PUMPS 8. 2.5 4 9 0. ‘Y’ Filter) at suction is recommended.24 0. Filter (eg.25 mm for upto 200 LPM flow & 50 mm for upto 800 LPM flow. while mounting on the small immersion tanks. No. These indicates the speciality of the product & helps in providing the correct spare or product. This power requirement is linearly proportional to the specific gravity of the liquid. call factory. Noise level : Maxm.15% on the flowrate & +/-10% on the head.4 1. maintain minimum & maximum levels as given in the catalog. 3.5 3.5 14 0. call factory for current details: Power in kW Current in A Power in kW Current in A Power in kW Current in A Power in kW Current in A 0. 72dB for all models. Similarly. These pumps need priming.75 1.34 0.7 3.Y.37 0. This table is for 2 pole (2800RPM) motors only.t outlet: The standard options are given below 6 O’ clock is the standard position maintained in factory. 8. apart from Horizontal mounting RMH pumps.I.5 16 MECHANICAL/ HYDRAULIC: 1.9 3 6 7. Terminal box position w. 11. Spares Ordering: While ordering spares or pumps. In case of pumps having bush bearings or mechanical seals (see the standard spares list in each page) they have to be ordered with carbide materials. RKM300 & RKM060. ensure that the minimum of two impeller stages are immersed in the liquid. Above 6 stages pumps are suitable for 30 on/off per hour.1 0.1 2. Coolant pump performance graphs shown in the catalog are for water as media.5 2. 6. Suction gap: Maintain minimum suction gap depending on the flow rate being taken. give the full model or frame name along with the sl. Outlet 6 Oí CLOCK 9 OíCLOCK Terminal Box 7. how an existing multistage pump can be connected to a Booster pump to enhance the pressure.5 5. Current rating: the current ratings of the pump motors. On/off cycles: The standard pumps upto 6 stages are suitable for 40 on/off per hours. if 1 kw is required for water. Cooling Emulsion .3 12 13 14 12 13 11 RK2 13 14 RK3 15 16 20 2 1 RK200 22 23 25 28 RV Series as per IS:2161 # Equivalent to other manufacturers Type 1 ^ Not as per IS:2161.COOLANT PUMPS CONVENTIONAL & MONOBLOCK COOLANT PUMP RV25…RV250 OPTIONS CONSTRUCTION Body Stem Impeller Impeller Cover Shaft AL C. Cutting Machines.Cooling/Cutting Oils Shaft Kinematical Viscocity .90mm2/s Pumping Temperature . Velox553/AL Velox553/CI EN8 APPLICATION Stem Gunmetal/S.18 175 140 72 110 160 G1” 3 0 180 95 120 93 80 7 0. 6 . Milling. – Tank. pipeset available in standard sizes.410 SPECIAL VERSIONS USED ON Avilable * ON/OFF Rotary switch * With flame proof motor for hazardous liquids * For Frequent ON/OFF Cycles * For Any Immersion depth * For high viscous liquids * To handle Hot Liquids upto 100 C HEAD IN METRES All lathes.5 RK1 4.18 215 140 72 140 160 G1” 3 2 180 150 175 100 100 8 0.37 260 140 72 140 160 G11/4” 3 2 180 150 175 100 250 13 0.54 H 1 H 2 A+0 B D d MAX MAX -1 MAX MAX -0.0-600C Teflon Coated/S.7 7.S Impeller Gunmetal/CI/S.1 190 100 72 105 115 G¾ ” 3 0 130 130 155 70 63 6 0.S.S Impeller Cover Gunmetal Types of Fluids . Printing machines Etc DISCHARGE IN LPM SIZE RV25# RV40 RV63 RK80^ RV100 RV160 RV250 Immersion Depth H 25/120 120 25/170 170 40/120 120 40/170 170 40/220 220 40/270 270 40/350 350 63/120 120 63/170 180 63/220 230 80/220 220 80/270 270 100/220 220 100/270 270 160/170 170 160/220 220 160/270 270 160/350+ 350 250/170 170 250/270 270 250/350+ 350 250/440+ 350 440 TYPE 160 100 72 105 115 G¾ ” 3 0 130 130 155 Flow at 2mtr hd ± 15% 70 25 160 100 72 105 115 G¾ ” 3 0 130 130 155 70 40 5 0. EDM wire and other conventional machines.5 4. CNC. retrofittings.I.20 235 140 72 140 160 G1” 3 2 180 150 175 100 160 10 0.Water .2 d1 BSP E -0 30 80 30 80 130 180 260 30 80 130 150 200 130 180 80 130 180 260 80 130 180 260 350 F L1 MAX L2 L3 Min Hd ± 10% Kw 4 0.5 6 6. Equivalent to other manufatures Type 2 + H2 Max is 50mm Extra – RV25-RV160 avalible for single phase 230V 50Hz.08 Old Wt Model in Kg Type 5 5. THEY CAN RUN DRY & WILL NOT HAVE AIR LOCKING PROBLEM. retrofittings. RK80.410 SPECIAL VERSIONS USED ON Avilable Extra * Immersion depth in step of 200mm * For high viscous liquids * To handle Hot Liquids upto 100 C HEAD IN METRES All lathes. Impeller Cover C.COOLANT PUMPS CONVENTIONAL & MONOBLOCK COOLANT PUMP RV25…RV250 CONSTRUCTION OPTIONS Body C.S Impeller Cover Gunmetal Types of Fluids .2 d1 BSP E -0.RV250.90mm2/s Pumping Temperature . * STANDARD SPARES : IMPELLER FOR LONG IMMERSION PUMPS.I./AL Stem C.5 34 RK600 300 220 430 200 82 200 225 G2” 42 250 165 126 2..1 30 RK400 300 220 375 200 82 175 225 G1½ ” 42 250 150 126 1. CNC.. Impeller C.Cooling/Cutting Oils Shaft Kinematical Viscocity .I..I.0-800C Teflon Coated/S.Cooling Emulsion . Shaft EN8 APPLICATION Stem Gunmetal/S. Printing machines Etc DISCHARGE IN LPM .RK800-WITH STD. IMMERSION DEPTH ARE GLANDLESS.RV25. ABOVE 300 MM.75 51 TYPE Immersion * ALL PUMPS . Cutting Machines.75 30 RK300 300 220 310 200 82 156 225 G1½ ” 42 250 126 126 1. Milling.25 42 RK800 300 220 465 200 82 230 225 G2” 42 250 180 126 3.. BUSH/SLEEVE.. RK275.Above Metalic Slinger H1 Max H2 Max A+0 -1 B Max D Max d -0.S Impeller Gunmetal/S. 7 . EDM wire.2 F L1 Max L3 Kw Depth H Wt in Kg RK275 300 220 310 200 82 156 225 G1½ ” 42 250 126 125 0.Water .I.S. I.75/5.I.90mm2/s Pumping Temperature .5 311 200 420 236 141 82 156 165 G1" 1 2 200 126 G1½ " 120 0.COOLANT PUMPS HIGH DISCHARGE PUMP (FLOODING TYPE) RK3.I.5 TO RK7 RKC100 TO 500 Coupled Version A (Optional Mounting) A (Optional Mounting) B TYPE COUPLED NON RSM SIDE IMMERSION H1 SUCTION DEPTH MAX H2 MAX COUPLED NON A+0 B D d d1 -1 MAX MAX -0.Water . GM/EN9 APPLICATION Stem Pump Housing Impeller Shaft Bush/sleeve Gunmetal Gunmetal Gunmetal Stainless Steel Carbide/Carbide Types of Fluids .I. Cyclone Filter. Heat treatment plants.Cooling Emulsion .Cooling/Cutting Oils Kinematical Viscocity .0-800C SPECIAL VERSIONS USED ON Avilable • With Flame Proof Motors to pump hazardous liquids • For frequent on/off cycles • For any immersion depths • For high viscous liquids • To handle hot liquids up 1000C • With below shown mounting (give A&B dimensions) All CNC machines to flush chips. C. Chip Conveyors.25/3.0 39 RKC-300 RK 6/311 311 200 500 310 181 82 208 215 G1½" 1 5 250 155 G1½ " 125 2. EN8 C.0 28 RKC-150 RK 4/311 RSM 4 311 200 420 236 141 82 156 165 G1" 1 2 200 126 G1½ " 120 1.5/2. C.I. RK3.5 30 RKC-200 RK 5/311 RSM 5 311 200 454 280 141 82 170 165 G1¼" 1 2 200 135 G1½ " 120 1. SERVICE AND SPARES AVAILABLE THROUGH OUR COUNTRY WIDE DEALERS NETWORK ASK US FOR MORE DETAILS 8 . C.75/1. Granite and Indoor Fountains.1/1.0 60 * STANDARD SPARES : IMPELLER.5 TO RK7 & COUPLED RKC SERIES OPTIONS CONSTRUCTION Body Stem Pump Housing Impeller Shaft Flange Bush/sleeve C.5/311 RSM 3.2 BSP S F L1 INLET MAX BSP L3 POWER IN Wt KW / HP in Kg Inch COUPLED H COUPLED RKC-100 RK 3. Grinding machnes.0 50 RKC-400 RK 7/311 311 200 590 430 181 82 225 215 G2" 1 5 250 165 G2½ " 125 3. BUSH & SLEEVE. EDM Wire cut machines. to transfer fluid for Filteration. ALL WET ENDS IN POLY-PROPELENE RPP5-IN HORIZONTAL MOUNTING. Flow : 400 LPM Max Head : 30 MTR. Max in both version 9 .COOLANT PUMPS DISCHARGE IN LPM RAJAMANE RPP .ALL POLYPROPELENE PUMPS More r o f ASK ls detai RPP160 IN VERTICLE IMMERSSION TYPE. ALL WET PARTS IN POLY-PROPELENE. 25 14 RMB-V-100 330 145 G1" G1’’ 160 110 180 100 2 0. 3. (0. AL./AL.37 16 NOTE : 1. lathes.I. RMB-V-50 300 145 G¾” G¾” 160 80 160 50 2 0. MECHANICAL SEAL AND GASKET (SEALING) SET.0-500C The liquid media should be prefiltered for moderete contamination./Gunmetal Gunmetal S. • STANDARD SPARES : IMPELLER. THE ABOVE SHOWN PERFORMANCE CURVE IS FOR WATER .I. USE OF NON RETURN VALVE CAUSES A DROP OF 10% IN THE PERFORMANCE.COOLANT PUMPS VERTICAL FOOT MOUNTED RMB-V SERIES OPTIONS CONSTRUCTION Body Stem Impeller Impeller Cover Shaft Mechanical seal C. FOLLOWING INITIAL PRIMING.S. EN8 Carbon/Ceramic APPLICATION Stem Impeller Impeller Cover Shaft Mechanical seal Gunmetal C. Kg. 20%).Cooling Emulsion . AND AVOID THE USE OF FOOT VALVE. USED ON Avilable • With flame proof motor for hazardous liquids.90mm2/s Pumping Temperature . UPTO 400 MM. and machining centres. THE SUCTION LINE MUST BE AIR TIGHT.Cooling/Cutting Oils Kinematical Viscocity . C. Carbide/Carbide SPECIAL VERSIONS Types of Fluids . DISCHARGE IN LPM TYPE H D d1 d2 d E A DISCHARGE (LPM) HEAD (M) Kw Wt. PUMP DELIVERS HIGHER DISCHARGE WHEN CONNECTED AT TANK LEVEL (20-30% MORE). HEAD IN METRES All CNC machines. 2.Water .I. FOR HIGHER DEPTHS UPTO 600 MM A NON-RETURN VALVE IS TO BE USED AT THE DELIVERY SIDE. WITHOUT NON-RETURN VALVE & WATER LEVEL 300 MM BELOW THE PUMP SUCTION. C. THE PUMP CAN PRIME. 10 . AND REDUCES AS THE WATER LEVEL DROPS.I.5-1 mm. Bronze C. and machining centres.Water .2 F L1 MAX L3 Kw Wt in Kg 275 100 82 156 115 G3/4" 30 130 115 120 0. BUSH & SLEEVE AND SPACERS 11 .I.75 20 350 100 82 170 115 G3/4" 30 130 135 120 1.54 12 • STANDARD SPARES : IMPELLER.L. lathes.S. C.54 18 300 100 82 156 115 G3/4" 30 130 126 120 0. RR25 DISCHARGE IN LPM TYPE No. deep hole drilling.Cooling/Cutting Oils Kinematical Viscocity .410 Carbon SPECIAL VERSIONS Avilable • With flame proof motor for hazardous liquids • With dual speed motor • Special versions to handle hot liquids upto 2000C HEAD IN METRES All CNC machines.I.90mm2/s Pumping Temperature .2 d1 BSP E -0.LOW IMMERSION RR50 SERIES Body Stem Impeller Impeller Cover Shaft Bush Bearing APPLICATION OPTIONS CONSTRUCTION C. of Stgs RR50 LP 1 RR50 HP 1 RR50-2 2 RR25 1 IMMERSION DEPTH (H) 140 190 240 290 370 140 190 240 290 370 160 210 260 310 390 H1 MAX 100 150 200 280 330 100 150 200 280 330 130 180 230 300 360 H2 MAX A+0 -1 B D MAX MAX d -0.Cooling Emulsion . EN8 GM Stem Impeller Cover Shaft Bush Bearing Types of Fluids . Most suited for through tool cooling.I.0-800C Clear Media .5 24 150 110 225 100 82 140 115 G3/4" 32 130 115 70 0./A.Prefiltered (50 microns) USED ON Gunmetal Gunmetal S.COOLANT PUMPS HIGH PRESSURE . chilling units and industrial washing machine. MECHANICAL SEAL 12 .2 d1 BSP S F L1 MAX L2 Kw Wt in Kg RKM02505 5 195 140 215 100 72 140 115 G¾” 7 130 105 70 0.S.5 30 • STANDARD SPARES : IMPELLER COVER.75 22 RKM0512 12 495 415 360 100 82 170 115 G¾” 7 130 135 70 1. Noryl/P. small CNC lathes and machining centres etc.75 22 RKM02515 15 435 380 360 100 82 170 RKM054 4 220 170 300 100 72 140 115 G¾” 7 130 135 70 1.COOLANT PUMPS MULTISTAGE COOLANT PUMPS RKM025 & RKM050 OPTIONS CONSTRUCTION Body Stem Impeller Impeller Cover Shaft Mechanical Seal C.I. EDM wire cut. C.Water . Noryl/P. IMPELLER. HEAD IN METRES D6a DISCHARGE IN LPM TYPE NO OF STAGES IMMERSION DEPTH (H) H1 MAX H2 MAX A+0 B -1 MAX D d MAX -0./AL.Cooling/Cutting Oils Kinematical Viscocity . spark erosion machines.0-500C SPECIAL VERSIONS Avilable • With Flame Proof Motors to pump hazardous liquids • With dual speed motor • With full water proof construction to pump demineralised / deionised water • Horizontal & Vertical foot moonted USED ON Most suited for chilling units. SiC/SiC SS316 SS316 Types of Fluids .5 30 115 G¾” 7 130 105 70 0.Cooling Emulsion .P.54 16 RKM058 8 360 290 320 100 82 156 115 G¾” 7 130 126 70 0.37 15 RKM02510 10 315 260 320 100 82 156 115 G¾” 7 130 126 70 0.I.5 CST max Pumping Temperature .P. SS410 Carbon/Ceramic Stem Shaft Mechanical Seal Impeller Impeller Cover APPLICATION Gunmetal / SS S. and machining centres. etc.R COOLANT PUMPS MULTISTAGE HORIZONTAL COOLANT PUMP RMH 0250 SERIES OPTIONS CONSTRUCTION Motor body Suction cover Impeller Delivery cover Impeller Cover Shaft AL C. Noryl SS410 APPLICATION Suction cover Delivery cover S.. • STANDARD SPARES : IMPELLER. lathes.25 # 112 71 170 144 169 380 7 0. Descaling.also available with 1 PHASE 230V.33 # 112 71 195 144 192 405 7 0. O-RINGS AND SPACERS 13 . of Stags A B RMH 02503 3 80 100 RMH 02504 4 90 RMH 02505 5 90 H1 H D L1 L MOUNTING HOLE DIA POWER (KW/HP) 63 140 114 146 355 7 0. Most suited for washing machines.25/0. drilling.S/Brass/Gunmetal Types of Fluids With spl. CAPACITOR START/RUN MOTOR. chilling units.18/0. Electrochemical deburring machine. female threading) # . MECHANICAL SEAL. Noryl C. Constn. 50HZ. BUSH & SLEEVE.5 # discharge REFER GRAPH TYPE (Dimension A & B are mounting holes for the pump/ SUCTION & DELIVERY is G 3/4”BSP.10CST) 0 – 500C USED ON Avilable • With flame proof motor for hazardous liquids All CNC machines. Kinematical Viscocity Pumping Temperature - SPECIAL VERSIONS Water Cooling Emulsion Cooling/Cutting Oils Light Chemicals Washing solutions 1 CST (Max.I.S/Brass/Gunmetal S.37/0.I. HEAD IN MTRS 3/4” BSP 3/4” BSP L DISCHARGE IN LPM DIMENSIONAL DET AILS DETAILS No. I. elegant in appearance.54 0. light weight. chilling units.50 2.0 25. long trouble free seals & bushes. (See page 10) • Side suction arrangement – see technical information sheet 4 & 5 USED ON DISCHARGE IN LPM TYPE RKM0604 RKM0606 RKM0608 RKM0612 RKM0616 RKM0620 No. IMPELLER COVER WITH BUSH. EDM wire cut machines and industrial washing machine. HEAD IN METRES Avilable • With flame proof motor for hazardous liquids • With dual speed motor / frequency drive.10 1. wide application.0-800C SPECIAL FEATURES All SS pump construction with sheet metal technology.2 160 160 160 160 160 160 d1 E BSP -0.Cooling/Cutting Oils Kinematical Viscocity ./SS Mechanical Seal SiC/SiC Types of Fluids .0 19. Stem C. Impeller SS316 Impeller Cover SS316 Shaft SS410 Mechanical Seal Carbon/Ceramic SPECIAL VERSIONS OPTIONS APPLICATION Stem Gunmetal/AL. Most suited for through tool cooling. All CNC machines. of IMMERSION DEPTH (H) 4 190 6 240 8 290 12 390 16 490 20 590 H1 MAX 110 150 200 300 400 500 H2 MAX 320 370 370 410 410 455 A+0 -1 140 140 140 140 140 140 B MAX 82 82 82 82 82 82 D MAX 140 156 156 170 170 206 d -0.75 1. and machining centres.25 3.Water . • Pressure booster pumps. lathes. to increase the pressure.Cooling Emulsion .45CST Pumping Temperature .0 23. efficient.0 • STANDARD SPARES : IMPELLER. double sealing stem.0 32.2 G1" 48 G1" 48 G1" 48 G1" 48 G1" 48 G1" 48 F 180 180 180 180 180 180 L1 MAX 105 126 126 135 135 155 L3 Kw 96 96 96 96 96 96 0.I. deep hole drilling.R COOLANT PUMPS MULTISTAGE COOLANT PUMP RKM 060 SERIES CONSTRUCTION Body C. MECHANICAL SEAL AND SPACERS 14 .0 20.00 Wt in Kg 16. SLEEVE. etc. motor will be single speed 2800 RPM. Most suited for through tool cooling.25 0. 2.I.S. deep hole drilling.75 30 168 25 RTH45/690 1090 690 400 190 3.cm) All CNC machines. S.S.6 30 132 20 RTH45/540 940 540 400 190 2. IMPELLER COVER WITH BUSH.=1 bsr or 1 kg/sq.R COOLANT PUMPS RAJAMANE-BRINKMANN RTH 45 SERIES HIGH PRESSURE PUMPS OPTIONS CONSTRUCTION Motor body Stem Impeller Impeller cover Mechanical Seal Shaft C. lathes.I. chilling units and industrial washing machine Temperature controlling units. C.3 1. • STANDARD SPARES : IMPELLER. MECHANICAL SEAL AND SPACERS 15 . SLEEVE. and machining centres.S. Please specify the same while ordering. 316 S. Constn. 316 APPLICATION Stem Bronze Types of Fluids With spl. " 100 160 ! DISCHARGE IN LPM MODEL A B C D1 POWER(kW) 2800 RPM 1440 RPM FLOW IN LPM HEAD IN MTRS 2800 RPM 1440 RPM RTH45/470 860 475 385 170 2. 316 SiC/SiC S.Conduit size will be given as per customer’s requirement.0 0. Dual speed motor is on request.Std.0 30 222 40 Note: 1. Kinematical Viscocity Pumping Temperature - Water Cooling Emulsion Cooling/Cutting Oils Light Chemicals Washing solutions 45mm2/s 0 – 800C SPECIAL VERSIONS • With frequency drive USED ON • With Dual speed Motor HEAD IN METRES (10 mtr. Kinematical Viscocity Pumping Temperature - Water Cooling Emulsion Cooling/Cutting Oils Light Chemicals Washing solutions 1 CST (Max. etc.33 # RMH-0603 3 90 112 71 170 144 180 465 7 0.I.25/0.5 discharge REFER GRAPH TYPE (Dimension A & B are mounting holes for the pump/ SUCTION & DELIVERY of G1”BSP. BUSH & SLEEVE.5 # RMH-0604 4 90 112 71 170 144 205 465 7 0.I. lathes. CAPACITOR START/RUN MOTOR. O-RINGS AND SPACERS 16 . Electrochemical deburring machine.S 1” BSP L DISCHARGE IN LPM DIMENSIONAL DET AILS DETAILS No. chilling units.37/0.S/Brass/Gunmetal C. female threading) # .also available with 1 PHASE 230V. Delivery cover S. drilling. • STANDARD SPARES : IMPELLER. Descaling.75 RMH-0606 6 100 125 80 179 165 255 560 10 0. MECHANICAL SEAL.75/1. Most suited for washing machines.R COOLANT PUMPS MULTISTAGE HORIZONTAL COOLANT PUMP RMH 060 SERIES OPTIONS CONSTRUCTION Motor body Suction cover Impeller Delivery cover Impeller Cover Shaft Mechanical seal APPLICATION C.S/Brass/Gunmetal SS316 Mechanical seal SiC/SiC C.. 50HZ.54/0.0 RMH-0608 8 100 125 80 179 165 305 610 10 1. 1” BSP 6 HEAD IN M.1/1.TR.I/AL Suction cover S. SS316 SS410 Carbon/Ceramic Types of Fluids With spl.10CST) 0 – 800C SPECIAL VERSIONS USED ON Avilable • With flame proof motor for hazardous liquids All CNC machines. and machining centres. of Stgs A B H1 H2 D L1 L MOUNTING HOLE DIA POWER (KW/HP) RMH-0602 2 80 100 63 162 114 155 380 7 0. Constn. C.Cooling Emulsion . Also suitable for Industrial washing. Type No./Gunmetal/Brass Gunmetal/S.54 18 19 140 82 140 160 G1” 30 180 105 110 140 82 157 160 G1” 30 180 125 110 1.0 46 • STANDARD SPARES : IMPELLER.L./A.100 SERIES CONSTRUCTION Body Stem Impeller Impeller Cover Shaft Bush Bearing C. 17 . C.S.Cooling/Cutting Oils Kinematical Viscocity .I. of Immersion H1 H2 Stgs Depth Max Max RKM-120 2 215 160 320 265 225 360 315 275 360 RKM-130 3 230 130 300 160 340 350 210 RKM-140 4 265 150 335 225 355 385 275 RKM-150 5 320 150 390 220 355 440 270 RKM-160 6 360 150 430 330 355 480 380 A+0 B D d -1 Max Max -0. BUSH AND SPACERS.L.R COOLANT PUMPS MULTISTAGE COOLANT PUMP RKM .7 42 140 82 170 160 G1” 30 180 135 110 2. deep hole drilling etc. A.I.2 d1 BSP E F L1 Max L3 Power in WT KW in KG 17 0.I.5 40 140 82 170 160 G1” 30 180 135 110 1. 410 SiC/SiC Types of Fluids .40 CST max Pumping Temperature .1 31 140 82 170 160 G1” 30 180 135 110 1. S. Most suited for through tool cooling.Water .I. EN8 GM OPTIONS Stem Impeller Impeller Cover Shaft Bush Bearing APPLICATION Gunmetal C.S.0-800C SPECIAL VERSIONS USED ON Avilable • With Flame Proof Motors to pump hazardous liquids • With dual speed motor • For chiller units HEAD IN METRES All CNC machines lathes and machining centres. 5 2. MECHANICAL SEAL AND SPACERS 18 S F 9 9 9 9 9 9 9 9 9 9 180 220 220 220 220 220 220 220 220 220 L1 MAX 160 215 215 215 220 220 165 215 220 220 L2 Kw 110 110 110 110 110 110 110 110 110 110 1.I.0-500C USED ON SPECIAL VERSIONS All CNC machines lathes and machining centres.2 160 180 180 180 180 180 180 180 180 180 d1 BSP G1" G1" G1" G1" G1" G1" G1" G1" G1" G1" • STANDARD SPARES : IMPELLER. DISCHARGE IN LPM TYPE RKM-206 RKM-210 RKM-214 RKM-218 RKM-222 RKM-226 RKM-304 RKM-306 RKM-308 RKM-310 NO OF IMMERSION STAGES DEPTH H 6 270 10 430 14 580 18 710 22 830 26 970 4 250 6 340 8 420 10 500 H1 H2 MAX MAX 180 410 320 410 480 410 580 410 720 480 840 480 120 370 190 410 280 480 350 480 A+0 -1 140 140 140 140 140 140 140 140 140 140 B MAX 82 100 100 100 110 110 82 100 110 110 D MAX 208 225 225 225 280 280 208 225 280 280 d ±0. BUSH & SLEEVE.5 3. SiC/SiC (for Grinding) SiC/SiC Types of Fluids . Brass C.0 5. grinding Machine. Also suitable for Industrial washing.0 4.R COOLANT PUMPS MULTISTAGE COOLANT PUMPS RKM200 & RKM300 CONSTRUCTION Body Stem Impeller Impeller Cover Guide vane Shaft Mechanical Seal Bush/Sleeve C.0 3. S.S. HEAD IN METRES Avilable • With Flame Proof Motors to pump hazardous liquids • With dual speed motor • Booster arrangment (see page 5) • Side suction arrangement (see page 5) • Upto 6 Stages available in Horizontal Construction.5 7. deep hole drilling etc.I.I.5 7.Cooling Emulsion .90mm2/s Pumping Temperature .S. Gunmetal/S.Water . Most suited for through tool cooling.7 5.5 . C.Cooling/Cutting Oils Kinematical Viscocity . Noryl-30% GF EN8 Carbon/Ceramic Carbon/Carbon OPTIONS APPLICATION Stem Impeller Impeller Cover Shaft Mechanical Seal Bush/Sleeve Gunmetal C.25 3.I. 5 34 355 140 79 178 160 G1¼" 30 180 126 110 1. Most suited for through tool cooling.1 26 1.Cooling Emulsion ./AL.7 46 375 140 82 208 160 G1¼" 30 180 165 110 2.1 30 340 140 79 157 160 G1¼" 30 180 126 110 1.I.S.R COOLANT PUMPS MULTISTAGE COOLANT PUMP RKM 250 SERIES CONSTRUCTION Body Stem Impeller Impeller Cover Shaft Bush Bearing C. AL. HEAD IN METRES Avilable • With flame proof motor for hazardous liquids • With dual speed motor DISCHARGE IN LPM TYPE RKM-252 RKM-253 RKM-254 RKM-255 No. lathes.410 Carbide Types of Fluids .I.25 54 • STANDARD SPARES : IMPELLER. and machining centres. C. of IMMERSION H1 Stgs DEPTH H MAX 2 150 95 205 135 280 205 330 255 3 265 190 335 260 385 310 4 320 240 390 310 440 380 5 375 295 445 365 495 435 H2 MAX 260 340 A+0 -1 140 140 B MAX 75 79 D MAX 157 157 d -0.I. C.90 mm2/s Pumping Temperature .Water .Cooling/Cutting Oils Kinematical Viscocity ./Gunmetal Gunmetal S. MECHANICAL SEAL AND SPACERS 19 .2 160 160 d1 E+0 BSP -1 G1¼" 20 G1¼" 30 F L1 L3 MAX 180 126 110 180 126 110 Kw Wt in Kg 1. EN8 Carbon/GM OPTIONS APPLICATION Stem Impeller Impeller Cover Shaft Bush Bearing Gunmetal C.I. deep hole drilling. BUSH & SLEEVE. chilling units and industrial washing machine.0-800C USED ON SPECIAL VERSIONS All CNC machines. grinding machine. /Gunmetal Gunmetal S.S.I. machining centres. C. HEAD IN METRES All CNC machines. DISCHARGE IN LPM TYPE RMS-402 RMS-403 RMS-404 RMS-406 RMS-602 RMS-604 RMS-802 RMS-803 So.90 mm2/s Pumping Temperature .5 7. SS410 EN31/EN24 APPLICATION Stem Impeller Impeller Cover Shaft Bush/Sleeve Gunmetal C. filteration units chip conveyors.R COOLANT PUMPS HIGH PRESSURE HIGH DISCHARGE COOLANT PUMPS RMS 400. • to handle larger chips for transfer to filteration unit.Water . etc. C. C.5 9. BUSH & SLEEVE (IF USED) 20 156 225 230 200 230 230 230 230 .0 7.0-800C USED ON SPECIAL VERSIONS Avilable • Imm. 600 & 800 OPTIONS CONSTRUCTION Body Stem Impeller Impeller Cover Shaft Bush/Sleeve C.s. lathes. • With flame proof motor for hazardous liquids.I. of IMMERSION H1 Stages DEPTH H MAX 2 3 4 6 2 4 2 3 375 450 525 675 375 525 375 450 295 370 445 595 295 445 295 370 H2 A+0 B D MAX -1 MAX MAX d -0.I.0 5. washing machines.0 30 45 50 65 53 62 56 70 200 200 200 200 200 200 200 200 82 82 82 82 82 82 82 82 • STANDARD SPARES: IMPELLER.Cooling/Cutting Oils Kinematical Viscocity .2 d1 BSP E+0 -1 F L1 MAX L3 Kw Wt in Kg 310 360 375 430 465 465 465 465 225 225 225 225 225 225 225 225 G1½" G1½” G1½" G1½" G2" G2" G2" G2” 42 42 42 42 42 42 42 42 250 250 250 250 250 250 250 250 126 165 180 180 165 180 180 180 126 126 126 126 126 126 126 126 3. Carbide Types of Fluids .5 7. depths in step of 200 mm. Most suited for grinding m/c.I.Cooling Emulsion .I.5 4.0 4. etc. DRIVEN PULLEY. DISC 21 .215 • STANDARD SPARES: BELT.DISC TYPE 230V.ROS SERIES OPTIONS CONSTRUCTION Motor Body Support Assembly Belt Wiper Drive Pulley Driven Pulley Powder coated Powder coated PU Teflon SS410 Nylon APPLICATION Motor Body SS316/304 Support Assembly SS316/304 Belt PVC/SS316 Driven Pulley SS316/304 Oil collection/seperation tray with mounting railings Types of Fluids Liquid Temperature - Oils Coolant Emulsion Mild Chemicals 0-500C USED ON STANDARD ACCESSORIES All CNC machines.5 . washing machine. 1 PHASE.BELT TYPE 230V1. 1 PHASE.04 KW Dimensions of ROS1 models: Model ROS1-40-225 ROS1-40-300 ROS1-40-500 Belt width Immersion Depth 40 40 40 225 300 500 75 ROS2 . • TIMER . 0. conventional machines.FOR ROS1 & ROS2 ROS1 . where floating oil is to be extracted for better life of coolant and finish of components. electro plating grinding machines.R COOLANT PUMPS OIL SKIMMERS . WIPER. 0.04KW MODEL : ROS2 . App.Coolant Emulsion Liquid Temperature . • STANDARD SPARES : IMPELLER 22 .R COOLANT PUMPS OIL SKIMMERS ./Bronze SS410 USED ON APPLICATION Types of Fluids .18/0.37/0. SPECIAL VERSIONS • Available with Flame Proof Motors.04KW models: Model Belt Immersion width Depth ROS3-40-225 ROS3-40-300 ROS3-40-500 ROS3-80-500 40 40 40 80 225 300 500 500 STIRRERS . 0.25 10 RSB71L 225 275 250 110 130 160 10 140 125 0.ROS SERIES Dimensions of ROS3 415V. Optional RPM 960 available for longer immersion stirrers. 3PH and RPM 1440. Mixing barrels. 3PH. RSB63L 225 275 210 95 115 140 10 120 115 0. • Any immersion depth Upto 600 mm DIMENSIONAL DET AILS DETAILS TYPE H1 H2 MAX A+0 -1 d PCD F S D MAX L1 MAX POWER (KW/HP) Weight in Kg.50 15 Supply Voltage 415V. 50HZ.RSB SERIES CONSTRUCTION Motor Body Impeller Shaft AL Al. coolant tanks.0-800C Chilling units. etc.Water . 3. etc. units. cooling units & many more. Torque motors For use in automats. Special voltages-110V.400Hz. Auto-Electric parts : Parts manufactured for automobile industry. Special purpose Induction Motors: for 1. hydraulic power pack. 2. advertisements.like class H. Hollow shaft motors 8. Standard motors are also manufactured. SPECIFICATIONS / DIMENSIONS ARE SUBJECT TO CHANGE DUE TO CONTINUOUS IMPROVEMENT IN THE PRODUCTS. Ask for detailed catalog of the same. etc. defence equipments. Speeds . 50/60Hz Mountings Extended shaft motors Special class of insulation & for humid conditions . 23 . 6. gear boxes. 5. 4.single or dual speeds High frequencies . 7. 560V. 220V.C M Y K R COOLANT PUMPS OTHER SPECIALITY PRODUCTS Small Induction motors: For various application in centralized lubrication. Application: Machining.6-21.CMYK R HIGH PRESSURE SCREW PUMPS . FFS Range: For Coolant emulsion: 10-300 LPM @ 10-100 bar For Oils: 10-330 LPM @ 10-120 bar. RIPL/P24/07 DS-R-MRK-001 R3 CHIP CUTTER PUMPS-SFC Range: For Coolant emulsion 1000-2600 LPM Pressure: 4 bar Motor power: 2. easy mounting. Features: Very specially designed cutters for long life. Grinding. Ask for detailed catalogue Manufacturer: Rajamane Industries Pvt. Ph: 080 . variable pressure operating either manually or electronically. Chip conveying. space saving immersion type design. Application: Filtration.2852 4410 / 2852 4262 Fax: 080 . very low maintenance. Mounting: Horizontal & Immersion type. Application: Machining. Whitefield Road. Bangalore . stirrer to cut the bundled chips.560 048. Mahadevapura Post.TFS. dirty liquids upto 20 mm chip sizes. Chip conveying.TAL Range: For Coolant emulsion: 1000-2600 LPM Pressure: 4 bar Motor power: 2. no mechanical seal-ensure longer life span. variable flow control by dual speed motor or frequency drive HIGH FLOW PUMPS-STA. quieter operation due to ground & hardened screws.com Dealer: . Motor power: 0. Ltd.6-21.SFL. available with frequency drive or pole changing motor to save power. Chip handling: Aluminium chips of any size. Special Versions: For foamed coolants. non-clogging type impellers. Flooding. requires no extra effort to take out chips from the tank or machining area. Special Versions: Any range & type of pump can be given with this attachment.rajamane. filtration can be simplified. Features: Very rugged construction.5-90. Features: Compact mounting.com Web: www. quick suctioning. Grinding. Through tool machining.2852 4320 E-mail: coolantpump@rajamane.. can handle almost all sorts of contamination/ chip types found in machine tool industry.00 kW. long life due to specially treated screw spindles & use of silicon carbide bushings. etc.5 kW. Filtration.5 kW.
Copyright © 2024 DOKUMEN.SITE Inc.