Quick Start Manual - Diversity Optimizer.pdf

March 29, 2018 | Author: Ansar Ali | Category: Device Driver, Installation (Computer Programs), Microsoft Windows, Usb, Icon (Computing)


Comments



Description

WHEN QUALITY MATTERSDiversity Optimizer 10.6 Installation Manual November 2010 SwissQual® License AG Allmendweg 8 CH-4528 Zuchwil Switzerland t +41 32 686 65 65 f +41 32 686 65 66 e [email protected] www.swissqual.com Part Number: 15-070- 200749-3 Confidential materials. Java™ is a U. Inc. INTERNET EXPLORER®. SwissQual acknowledges the following trademarks for company names and products: Adobe®. Diversity Unattended™. QualiPoc Freerider™. transmitted.S. Intel Pentium®. or translated into any human or computer language without the prior written permission of SwissQual AG. explain issues which may not be covered by the documents. protected and privileged intellectual property.Five®. QPControl™. Redwood City. QualiPoc Mobile™. QualiWatch-S™. DIMENSION®. VQuad®. NQWeb™. Inc. Microsoft®. NiNA+™. . Inc. SMARTPHONE®.2010 SwissQual AG. Linux® is a registered trademark of Linus Torvalds. UNIX® is a registered trademark of The Open Group. you must acknowledge the respective text or logo trademark somewhere in your text. transcribed.S. Oracle® is a registered US trademark of Oracle Corporation. and OPTIPLEX® are registered trademarks of Dell Inc. LATITUDE®. No part of this publication may be copied. trademark of Sun Microsystems. Intel Itanium®. Google® is a registered trademark of Google Inc. VQuad-HD™ are trademarks of SwissQual AG. NOKIA® is a registered trademark of Nokia Corporation. Diversity® as well as the following logos are registered trademarks of SwissQual AG. Apple is a trademark of Apple Computer. VMon™. Microsoft Windows®. NQDI™. NQTM™. QPView™. Copyright 2000 . NQView™. QualiWatch-M™. NiNA™. TestManager™. U-BLOX® is a registered trademark of u-blox Holding AG. SystemInspector™. Seven. SwissQual’s liability for any errors in the documents is limited to the correction of errors and the aforementioned advisory services. SIERRA WIRELESS® is a registered trademark of Sierra Wireless. distributed. Microsoft Windows NT®. NQAgent™. Diversity Explorer™. and Adobe Postscript® are trademarks of Adobe Systems Incorporated. When you refer to a SwissQual technology or product. SAMSUNG® is a registered trademark of Samsung Corporation. SwissQual will. All information in this document is regarded as commercial valuable. NQComm™. SQuad®. TABLET® are registered trademarks of Microsoft Corporation. Adobe Acrobat®. ELEKTROBIT® is a registered trademark of Elektrobit Group Plc. QualiPoc iQ™. and Windows Vista® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries U. and is provided under the terms of existing Non-Disclosure Agreements or as commercial-in-confidence material. stored in a retrieval system. Diversity Ranger™. TRIMBLE® is a registered trademark of Trimble Navigation Limited.SwissQual has made every effort to ensure that eventual instructions contained in the document are adequate and free of errors and omissions. All rights reserved. QualiPoc Static™. and Intel Xeon™ are trademarks or registered trademarks of Intel Corporation. SwissQual®. if necessary. California. Intel®. NetQual®. QualiPoc®. .......................................................................................................................................... 11 Figure 3-8 Run Tasks icon...............................................................................................................................................................Diversity Optimizer 10............................................... 13 Removing a Task ........................................................................................................................................................................................................................................................................................................ 1 Overview ......................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 13 Contents | CONFIDENTIAL MATERIALS ii ....................................................................... 1 System Requirements .......................................6 Installation Manual © 2000 ....... 9 Figure 3-5 Device configuration dialog box ....................... 3 Figure 2-2 Installation completed ................................................................................................................................ 10 Figure 3-6 New device ........................................................... 1 Figure 2-1 Optimizer setup type ........................................................................................... 8 Adding a Device in NQView ............................... 3 Installing the MCM Driver .................................................................. 9 Figure 3-2 Start Diversity icon .............................................................................................................................................................. 12 Tasks ................................................................................................... 7 Figure 3-1 NQView desktop icon .......................................................................................................................................................................................................................................................................................................................................................................... 4 3 Using Diversity Optimizer ............... 5 Figure 2-5 Computer Management window .................................................................................... 2 Related Documents .....................................................................................................12 Adding a Task ........................................ 4 Figure 2-4 Location of MCM driver .........................................................................................................2010 SwissQual AG Contents 1 Introduction .......................................................... 14 Viewing Measurement Data ................................. 8 Changing the Settings for a Device .......................................................................................... 6 Figure 2-7 MCM USB controllers ...............................................14 NQView Walk Mode..................................................................................................................................................................................... 2 2 Installing Diversity Optimizer . 12 Figure 3-10 Specify task dialog box ............................................................................................................... 9 Figure 3-4 Hardware detection progress .............................................. 10 Removing a Device .............. 12 Running a Task ........................................................................................................................................................................................................................................................... 9 Figure 3-3 Connect Device icon ...................................................................................................................................... 3 Figure 2-3 MCM-PC interface cable ...........................................................15 Figures Figure 1-1 Diversity Optimizer system .............................................................. 10 Figure 3-7 Details area of Device configuration dialog box ............................................................................................................................................... 8 Measurement Devices ....................................... 12 Figure 3-9 Task list dialog box ................. 5 Figure 2-6 USB MCM Control Channel Properties window ... ................... 14 Figure 3-15 NQComm Settings dialog box ...... 15 Contents | CONFIDENTIAL MATERIALS iii ...................................................................... 14 Figure 3-13 Stopping a task .................................................................................................................................................................................... 13 Figure 3-12 Start task icon.................6 Installation Manual © 2000 .................................................................2010 SwissQual AG Figure 3-11 New task in Task list dialog box ........................................................Diversity Optimizer 10................................................................................. 14 Figure 3-14 Delete task confirmation dialog box ...................................................... NQView can also replay a measurement in real-time from the measurement files. Overview The Diversity Optimizer software controls and operates measurement devices from a standalone computer.pdf. measurement devices. and video quality measurements. A Diversity PCM installation contains Maintenance Center which you can use to access Measurement Control.pdf. see Manual – NetQual . References: Contains file samples for measurement tests Diversity PCM: Enables a PCM to operate the measurement devices. QuickTime: Provides QuickTime support RealPlayer: Provides RealPlayer support Installers for third-party Windows drivers: Contains the drivers that you need to use your 1 CONFIDENTIAL MATERIALS        Chapter 1 | Introduction .6 Installation Manual © 2000 . NQView: Displays real-time measurement values from the measurement devices on the controlling PC. For more information. For more information. see the Diversity Hardware User Manual. data. NQComm: Provides communication between TestManager. Measurement Engine. You can connect a device to a USB port or a data card slot on the computer. and SQL databases. and test results.pdf. Diversity Optimizer automatically installs the following software on your computer:  TestManager: Creates and manages tests for voice. see Manual NetQual . TestManager requires a Microsoft SQL database to store information about the test units.NQComm.NQView.Diversity Optimizer 10. Figure 1-1 Diversity Optimizer system Note: For information on Diversity measurement devices. see Manual – NetQual . test plans.2010 SwissQual AG 1 Introduction The Diversity Optimizer 10. and Device Manager. PCMs. For more information.TestManager. Test Manger runs as a Windows service that you can access through a web browser on the same machine at: http://localhost:8080.6 Installation Manual describes how to install and to use Diversity Optimizer. 6 Installation Manual © 2000 .1 GHz or faster processor Minimum of 1 GB of RAM 100 MB of available hard disk space Supported hard disk format: NTFS Related Documents    Manual – NetQual . To obtain a licence key. click the Regional Options tab. Computer with Intel Pentium-M 1. open Regional and Language Options in Control Panel. and select an English location in the drop-down box.2010 SwissQual AG measurement devices with Optimizer  Documentation: Contains user manuals for the software System Requirements Important: You need a valid licence key to use Diversity Optimizer.  Supported Operating System: Windows XP Professional Service Pack 2 (English) with administrative rights and the locale set to English o     To set the locale to English. contact SwissQual support.pdf Manual .NetQual .Diversity Optimizer 10.NQView.pdf Manual .pdf Chapter 1 | Introduction CONFIDENTIAL MATERIALS 2 .MCM-PC Interface Cable.TestManager. 6 Installation Manual © 2000 . On the Setup Type page. Click Next and at the end of the installation. Important: You cannot control a Diversity hardware system. To install Diversity Optimizer 1. In the 'sa' password box. 2. click Finish. Figure 2-1 Optimizer setup type 3. To use an existing installation. type the password for your SQL Server.2010 SwissQual AG 2 Installing Diversity Optimizer Diversity Optimizer automatically installs the controlling and operating software that you need to run measurement devices from a standalone PC. If your machine does not contain a SQL Server installation. click Optimizer. 4.Diversity Optimizer 10. you need to install the Windows drivers for the measurement devices that you want to use. 5. that is. one or more PC Modules (PCM) with Diversity Optimizer.exe. Figure 2-2 Installation completed Chapter 2 | Installing Diversity Optimizer CONFIDENTIAL MATERIALS 3 . click Install new named instance of SQL Server 2005 Express. click Use an installed instance of SQL Server 2000 or 2005 a b In the Instance name list. Double-click Setup. After you install Optimizer. select your server. MCM-PC Interface Cable. Note: If the wizard does not start. go to step 3. see the Manual . Connect the MCM to the laptop. Figure 2-3 MCM-PC interface cable 2. Note: You need a MCM-PC interface cable to use the MCM with the laptop. for example.Diversity Optimizer 10. Connect the USB plug of the cable to the laptop. On the laptop.pdf document To install the MCM driver 1. On the Please choose your search and installation options page.2010 SwissQual AG Installing the MCM Driver If you want to use the Mobile Connection Module (MCM). b c Select Install from a list or specific location and click Next. Connect the car charger plug of the cable to a power source. and then click Browse. install the Windows driver for the MCM. For more information. select Include this location in the search.6 Installation Manual © 2000 . click Next. you need to install the Windows drivers for the MCM. to a wall socket through an AC adapter. a On the Welcome page of the Found New Hardware Wizard. a b c Connect the 10-pin LEMO plug of the MCM-PC interface cable to the socket on the front panel on the MCM. Chapter 2 | Installing Diversity Optimizer CONFIDENTIAL MATERIALS 4 . On the right. double-click Universal Serial Bus controllers. that is. click Finish. exclamation mark (!) in front of the DLP2232M entry. a Right-click DLP2232M and click Properties. a b c d Right-click My Computer and click Manage Computer. and at the end of the process. Figure 2-5 Computer Management window 5 CONFIDENTIAL MATERIALS Chapter 2 | Installing Diversity Optimizer . Verify the properties of the MCM driver. In the console tree on the left.2010 SwissQual AG Figure 2-4 Location of MCM driver d Go to the following location.Diversity Optimizer 10. Ensure that you see the following entries:   USB MCM Control Channel USB MCM Data Channel 4. C:\Program Files\SwissQual\Diversity\Drivers\MCM\Driver e In the Hardware Installation window. install the driver for the USB MCM Control Channel. click OK. click Device Manager. If you see a warning symbol.6 Installation Manual © 2000 . click Continue Installation. 3. and then click Next. Select Install from a list or specific location and click Next. click Device Manager. click Reinstall Driver. Verify the properties of the MCM driver. and then click Browse (see Figure 2-4). and at the end of the process. In the console tree on the left. select Include this location in the search. a b c d Right-click My Computer and click Manage Computer. click OK. Figure 2-6 USB MCM Control Channel Properties window g process. On the Please choose your search and installation options page.2010 SwissQual AG b c d e On the General tab of the DLP2232M Properties dialog box. 5. click Finish.6 Installation Manual © 2000 . On the right. C:\Program Files\SwissQual\Diversity\Drivers\MCM\Driver f In the Hardware Installation window. click Continue Installation. Go to the following location. and then click Next. Ensure that you see the following entries:   USB MCM Control Channel USB MCM Data Channel Chapter 2 | Installing Diversity Optimizer CONFIDENTIAL MATERIALS 6 . click Finish.Diversity Optimizer 10. double-click Universal Serial Bus controllers. Diversity Optimizer 10.6 Installation Manual © 2000 .2010 SwissQual AG Figure 2-7 MCM USB controllers Chapter 2 | Installing Diversity Optimizer CONFIDENTIAL MATERIALS 7 . Install the Windows driver for your measurement device.    To connect a USB device. Chapter 3 | Using Diversity Optimizer CONFIDENTIAL MATERIALS 8 . you need to perform the following tasks to prepare your measurement device:     Install the Windows drivers for your device Connect the device to your computer and configure the drivers Configure the device in NQView Create a task for the device in NQView Note: You can only use a measurement device that you directly attach to your computer. Measurement Devices You can use the following measurement devices with Optimizer:      Mobile phone Datacard Dialup device GPS Bluetooth device Scanner Adding a Device in NQView NQView provides you with two options to add a measure device. Note: These installers are also on the installation CD for Diversity Optimizer. If you manually add a device. namely a hardware detection option and a manual option. connect the cable to a USB port on your computer.Diversity Optimizer 10. insert the card in the PCMCIA slot of the computer. Double-click the NQView icon on the Windows desktop. you need to manually configure the dialup settings for the device in the Phone and Modem Options in the Windows Control Panel. The hardware detection option automatically detects the Windows port settings for the device.6 Installation Manual © 2000 . consult the Windows help system. consult the Windows help system. doubleclick the installer. You can only add a scanner with the hardware detection option. connect the cable to a USB port. and then turn on the scanner. For more information. b Connect the device to your computer and wait for Windows to configure the driver. a In the C:\Program Files\SwissQual\Diversity\Drivers\<name of device>\Installer folder. To connect a scanner. you need to determine these settings through the Windows Control Panel.2010 SwissQual AG 3 Using Diversity Optimizer Before you can use Diversity Optimizer. To add a device in NQView 1. Important: You can only add a dialup device manually. 2. For a description on how to configure these settings. Important: After you connect a dialup device. and then follow the instructions. To connect a datacard. In the Device configuration dialog box. click HW detection.6 Installation Manual © 2000 . Figure 3-2 Start Diversity icon 4. click Connect Device. add the device. 9 CONFIDENTIAL MATERIALS Chapter 3 | Using Diversity Optimizer . Figure 3-3 Connect Device icon 5. On the Optimizer toolbar. click Start Diversity. On the Optimizer toolbar. select the device in the Dial-up network entry list in the Details area.  For all devices. Note: This process can take several minutes to complete. Figure 3-4 Hardware detection progress  To add a dialup device. click Add dialup. The NQComm and the Diversity Maintenance Center windows open.Diversity Optimizer 10.2010 SwissQual AG Figure 3-1 NQView desktop icon 3. and then specify the remaining settings for the device. except for a dialup device. click the device in the list. In the Device configuration dialog box. for example. 2. ensure that you see the device in the list. specify the settings for the device. On the Optimizer toolbar. except for scanners.6 Installation Manual © 2000 . Figure 3-6 New device Changing the Settings for a Device You can change the settings for the measurement devices that you add in NQView. click Connect device. To change the settings for a device 1. Figure 3-5 Device configuration dialog box 6. you need to add the device with the Phone and Modem Options Control Panel in Windows.Diversity Optimizer 10. and then restart NQView. Click Refresh. and then click Close. Chapter 3 | Using Diversity Optimizer CONFIDENTIAL MATERIALS 10 .2010 SwissQual AG Note: If you do not have the option to select a device in the Dial-up network entry list. In the Details area. a new Device name. 3. Click Update unit. Chapter 3 | Using Diversity Optimizer CONFIDENTIAL MATERIALS 11 .6 Installation Manual © 2000 .2010 SwissQual AG Figure 3-7 Details area of Device configuration dialog box 4.Diversity Optimizer 10. and then click Close. 2. and remove tasks in NQView. click Yes. In the Specify task dialog box. click Refresh. Adding a Task After you add a device. On the Optimizer toolbar.2010 SwissQual AG Removing a Device This section describes how to remove a measurement device from the system configuration. click Run Tasks. run. In the Confirm dialog box. 3. and then click Delete device.6 Installation Manual © 2000 . select the device in the Device list.Diversity Optimizer 10. On the Optimizer toolbar. 4. click Connect device. Tasks This section describes how to add. Chapter 3 | Using Diversity Optimizer CONFIDENTIAL MATERIALS 12 . Figure 3-8 Run Tasks icon 2. Figure 3-9 Task list dialog box 3. To view your changes. In the Task list dialog box. In the Device configuration dialog box. To remove a device 1. you can configure a measurement task for the device to run. click Add task. click the device that you want to remove. To add a task 1. click Run Tasks. To start a task 1.2010 SwissQual AG Figure 3-10 Specify task dialog box 4. 2. In the Type of test box. Specify the options for the test. Figure 3-11 New task in Task list dialog box Running a Task This section describes how to manually start a task. select the test that you want to run.Diversity Optimizer 10. and then click OK. click the Start task icon for the task that you want to run. 5. The test appears in Task list. In the Task list. Chapter 3 | Using Diversity Optimizer CONFIDENTIAL MATERIALS 13 .6 Installation Manual © 2000 . On the Optimizer toolbar. To stop the task.2010 SwissQual AG Figure 3-12 Start task icon 3. In the Confirm dialog box. Figure 3-13 Stopping a task Removing a Task This section describes how to remove a task from the task list. For a Chapter 3 | Using Diversity Optimizer CONFIDENTIAL MATERIALS 14 . 2. click the task.6 Installation Manual © 2000 . On the Optimizer toolbar. and then click the Delete icon 3. Figure 3-14 Delete task confirmation dialog box Viewing Measurement Data You can view live measurement data or recorded measurement data with NQView monitors. In the Task list.Diversity Optimizer 10. click the Stop task icon . . To remove a task 1. click Yes. click Run tasks. Add a map coordinate. 3. if you want to manually input these coordinates. Chapter 3 | Using Diversity Optimizer CONFIDENTIAL MATERIALS 15 . At the end of the measurement. click Walk point on the Tools menu. open NQComm. you can change the Path Mode of NQView to Walk. click Drive on the Path Mode menu. the files that contain the measurement data are in the C:\Documents and Settings\All Users\Application Data\SwissQual\Diversity\MeasurementFiles folder. click Settings on the Configuration menu. Figure 3-15 NQComm Settings dialog box NQView Walk Mode By default a GPS receiver provides the map coordinates during a measurement. click Monitors. when you are indoors.6 Installation Manual © 2000 . 4. and then click the map where you want to add the point. and then click your map.2010 SwissQual AG description on how to use these features. To change the location of this folder.  During a measurement. see the Manual .Diversity Optimizer 10.NQView. To use the Walk mode 1. click Walk. and then enter a new location in the Measurement files directory box on the General tab. On the Path Mode menu.  On the Navigation panel in NQView. By default. NQView saves the Walk points that you manually add to the map as latitude and longitude coordinates in the measurement file. In this mode.NetQual .pdf. However. 2. Open your map monitor. for example.
Copyright © 2024 DOKUMEN.SITE Inc.