Quantum Catalog HR

March 17, 2018 | Author: Ahmed Dola | Category: Dental Implant, Mouth, Dentistry, Medical Specialties


Comments



Description

TMDENTAL IMPLANTS TM CATALOG 2007 QVS SYSTEM Implants Abutments Components Armamentarium TM TM DENTAL IMPLANTS QVS™ SYSTEM 201 NORTH UNIVERSITY DR. SUITE 101 PLANTATION, FLORIDA 33324 Tel: (800) 600-4845 Tel: (954) 474-2556 Fax: (954) 474-2533  Copyright 2001 Quantum BioEngineering, Ltd. All Rights Reserved Email [email protected] www.quantumimplants.com ........................6 Hex Abutments............... 9-10 Res-Q Low Profile Abutments............. 7 ................................... 17 18 Armamentarium........Table of Contents: Implants. Q-Fix Removable. 5 ....... 13-14 Rapido Implant Mounts.........................Ring Abutments..................................................... 19-28 Quantum BioEngineering.......................................8 O....... ..................../........................Fax: (954) 474-2533 .. 11-12 Removable Bar Abutments.......4 C & B TaperLock Abutments............. 3 .Tel: (954) 474-2556 ..Tel: (800) 600-4845 .................................. Ltd...... 15-16 Implants Analog & Transfer Components............................................................... RBM. . and BioTi™ acid etch surface treatment Three types of engagement mechanism between the abutment and the implant Buttress type Fin and Thread favors loading bone in compression Fins and Threads are designed with flat surface at the major diameter of the thread to decrease stress concentration in the bone during lateral forces of mastication Thread implants can be placed as Push-In or Thread-In into the osteotomy Improved abutment engagement mechanism designed to improve a sealed interface (Bacterial Seal) The implants have lateral vertical vents for proper pressure relief during insertion Lateral vertical vents provides anti-rotation of the implant QVS™ System components have beveled connections between the Hex-Bevel Abutment and the Implant Taper apical end with proper engineering design for support and stress distribution 1 Quantum BioEngineering.Tel: (800) 600-4845 .Implants Thread Implant • • • • • • • • • • Fin Implant Two types of implants are available: Fin Implants and Thread Implants Three types of surface treatment: HA coated. Ltd.Tel: (954) 474-2556 .Fax: (954) 474-2533 . 15o. Ltd. Quantum BioEngineering. TaperLock Abutment Titano-LockTM fit 360o abutment positions Straight. 15o. This provides the practitioner with a unique selection of prosthetic components for fixed and removable prosthesis. . 15o. ease of abutment placement and trouble free laboratory procedures. ideal esthetics.Tel: (800) 600-4845 .ProsthointegrationTM Abutment System Interchangeable between Fin and Thread Implants 3 Types of Engagement Mechanism TaperLock TaperLock Thread Hex Abutment Engagement: The QVS™ System provides three different types of engagement mechanism interchangeable among Fin and Thread Implants. 25o angulation TaperLock Thread Abutment Titano-LockTM fit Ideal for single anterior From straight to 25o angulation Hex Abutment Titano-LockTM fit 12 internal hex surfaces Straight.Tel: (954) 474-2556 . 25o angulation Abutments available in straight.Fax: (954) 474-2533 2 . and 25o to allow parallelism. 0 x 14 Part Number HA 100-135-009HA 100-135-011HA 100-135-014HA 100-140-009HA 100-140-011HA 100-140-014HA 100-150-009HA 100-150-011HA 100-150-014HA Part Number Part Number BioTi RBM 100-135-009RBM 100-135-011RBM 100-135-014RBM 100-140-009RBM 100-140-011RBM 100-140-014RBM 100-150-009RBM 100-150-011RBM 100-150-014RBM 100-135-009BT 100-135-011BT 100-135-014BT 100-140-009BT 100-140-011BT 100-140-014BT 100-150-009BT 100-150-011BT 100-150-014BT 3 Quantum BioEngineering.Tel: (800) 600-4845 .Implants Thread Implant 3:1 Scale 1:1 Detail Drawing Part Name Thread Implant 3.Tel: (954) 474-2556 .0 x 09 Thread Implant 5.Fax: (954) 474-2533 .5 x 14 Fin Implant 4.0 x 09 Thread Implant 4.0 x 11 Fin Implant 4. .0 x 14 Thread Implant 5.0 x 09 Fin Implant 4.0 x 11 Fin Implant 5.0 x 09 Thread Implant 3.0 x 11 Thread Implant 4.5 x 09 Thread Implant 3.5 x 11 Thread Implant 3.5 x 09 Fin Implant 3.5 x 11 Fin Implant 3.0 x 14 Part Number Part Number Part Number RBM HA BioTi 200-135-009HA 200-135-011HA 200-135-014HA 200-140-009HA 200-140-011HA 200-140-014HA 200-150-009HA 200-150-011HA 200-150-014HA 200-135-009RBM 200-135-011RBM 200-135-014RBM 200-140-009RBM 200-140-011RBM 200-140-014RBM 200-150-009RBM 200-150-011RBM 200-150-014RBM 200-135-009BT 200-135-011BT 200-135-014BT 200-140-009BT 200-140-011BT 200-140-014BT 200-150-009BT 200-150-011BT 200-150-014BT Thread Implant 3:1 Scale 1:1 Detail Drawing Part Name Part Number Part Number Part Number RBM HA BioTi Thread Implant 3.0 x 14 200-130-009HA 200-130-011HA 200-130-014HA 200-130-009RBM 200-130-011RBM 200-130-014RBM 200-130-009BT 200-130-011BT 200-130-014BT Fin Implant 3:1 Scale 1:1 Detail Drawing Part Name Fin Implant 3.0 x 11 Thread Implant 3.5 x 14 Thread Implant 4.0 x 14 Fin Implant 5.0 x 11 Thread Implant 5.0 x 09 Fin Implant 5. Ltd. Fax: (954) 474-2533 4 . .Tel: (954) 474-2556 .Tel: (800) 600-4845 .Two types of dental implants available: Fin and Thread Thread Implants are placed either with Push-In or Thread-In Technique Fin Implants are placed with Push-In Technique Totally interchangeable TaperLock and Hex abutments Both implants can be placed from 2mm below the crest to the bevel portion above the crest 3 Types of surface treatment: HA Hydroxyapatite RBM Resorbable Blasting Media BioTi™ (Biological Titanium Interface) Acid Etch Quantum BioEngineering. Ltd. 5-00 C-B TaperLock Abutment 3.0-25 Part Number 500-135-000 500-135-015 500-135-025 500-140-000 500-140-015 500-140-025 500-150-000 500-150-015 500-150-025 Abutment for restoring fixed crown and bridge restorations Taperlock Short Abutment 1:1 Detail Drawing Part Name C-B TaperLock Thread Abutment 5.0 Custom TaperLock Thread Abutment 5.0-15 C-B TaperLock Thread Abutment 5. .5-00 C-B TaperLock Thread Abutment 4.0 Part Number Indicated for custom preparation of single restorations and when extra anti-rotation is desired Ideally for single anterior mandibular or maxillary restorations 501-235-025 501-240-025 501-250-025 5 Quantum BioEngineering.0-00 C-B TaperLock Abutment 4.5-15 C-B TaperLock Abutment 3.0-15 C-B TaperLock Abutment 5.0-15 C-B TaperLock Abutment 4.Tel: (954) 474-2556 .Tel: (800) 600-4845 .Fax: (954) 474-2533 .0-00 C-B TaperLock Thread Abutment 5.0-25 C-B TaperLock Abutment 5. Ltd.5 Custom TaperLock Thread Abutment 4.0-00 Part Number 501-135-000 501-140-000 501-150-000 Indicated for single restorations when extra anti-rotation is desired Ideally for single anterior mandibular or maxillary restorations Custom TaperLock Thread Abutment 1:1 Detail Drawing Part Name Custom TaperLock Thread Abutment 3.0-00 C-B TaperLock Thread Abutment 5.5-25 C-B TaperLock Abutment 4.Abutments Taperlock Abutment 1:1 Detail Drawing Part Name C-B TaperLock Abutment 3.0-00 C-B TaperLock Abutment 5.0-25 Part Number 501-135-000 501-140-000 501-150-000 Indicated for single restorations when extra anti-rotation is desired Ideally for single anterior mandibular or maxillary restorations Taperlock Thread Abutment 1:1 Detail Drawing Part Name C-B TaperLock Thread Abutment 3. One Stage 1:1 Detail Drawing Part Name Healing Plug One Stage 5.Fax: (954) 474-2533 6 .Tel: (954) 474-2556 .Two Stage 1:1 Detail Drawing Part Name Part Number Used as a Two-Stage Healing Plug when planning to restore with TaperLock Abutments Healing Plug Two Stage 4.One Stage 1:1 Detail Drawing Part Name Healing Plug One Stage 3.Short .0 500-200-100 Quantum BioEngineering.5 Healing Plug One Stage 4.0 Healing Plug One Stage 5.0 Part Number 500-050-100 For Shorter TaperLock Abutments Healing Plug .Healing Components Healing Plug . .0 Part Number 500-135-100 500-140-100 500-150-100 Used as a One-Stage Healing Plug when planning to restore with TaperLock Abutments Healing Plug . Ltd.Tel: (800) 600-4845 . Hex Abutments Cervical Contour Hex Abutment 1:1 Detail Drawing Part Name Cervical Contour Hex Abutments: 3.0-25 600-135-000 600-135-015 600-135-025 600-140-000 600-140-015 600-140-025 600-150-000 600-150-015 600-150-025 Part Number Hex Abutment with a hex and a bevel engagement The angled ones have 12 positions Hex Abutment Locking Screw 1:1 Detail Drawing Part Name Part Number To hold Cervical Contour Hex Abutments Hex Abutment Locking Screw 600-111-000 Healing Cap .0-25 5.0 Healing Cap Two Stage 5.0 Part Number 600-235-100 600-240-100 600-250-100 Used as a Two-Stage Healing Cap when planning to restore with Hex-Bevel Abutments 7 Quantum BioEngineering.Tel: (954) 474-2556 .5 Healing Cap One Stage 4.5-00 3.Two Stage 1:1 Detail Drawing Part Name Healing Cap Two Stage 3.Tel: (800) 600-4845 .5-25 4.5 Healing Cap Two Stage 4. Ltd.Fax: (954) 474-2533 .0-00 5.0-15 4.0-00 4.One Stage 1:1 Detail Drawing Part Name Part Number Healing Cap One Stage 3.0-15 5.0 600-135-100 600-140-100 600-150-100 Used as a One-Stage Healing Cap when planning to restore with Hex-Bevel Abutments Healing Cap .5-15 3.0 Healing Cap OneStage 5. . Fax: (954) 474-2533 8 .Tel: (954) 474-2556 . to achieve optimal parallelism Cervical contour allows ideal gingival adaptation and emergence profiles Quantum BioEngineering.Tel: (800) 600-4845 .• • • • • It is well known in dentistry that a chamfer margin provides better retention and a better seal than a shoulder margin Hex abutment engages the implant on a hex over a tapered portion Decreases stress of the retention screw Angled abutments have 12 sided hex (duodec). Ltd. . allowing more positions. 0-25 Part Number 503-240-000 503-240-015 503-240-025 Same as above when longer abutments are needed (2mm longer) O-Ring Transfer Analog 1:1 Detail Drawing Part Name Part Number Used as transfer analog or as lab processing analog with O-ring TaperLock Abutments O-Ring Transfer Analog 503-400-000 9 Quantum BioEngineering.0-25 Part Number 503-040-000 503-040-015 503-040-025 Free standing abutments for TissueSupported O-Ring Removable Prosthesis O-Ring TaperLock Abutment 1:1 Detail Drawing Part Name O-Ring TaperLock Abutment 4.0-00 O-Ring TaperLock Abutment 4.0-15 O-Ring TaperLock Abutment Long 4.0-15 O-Ring TaperLock Abutment 4.Tel: (800) 600-4845 . .Fax: (954) 474-2533 . Ltd.Tel: (954) 474-2556 .0-25 Part Number 503-140-000 503-140-015 503-140-025 Free standing abutments for TissueSupported O-Ring Removable Prosthesis O-Ring TaperLock Abutment Long 1:1 Detail Drawing Part Name O-Ring TaperLock Abutment Long 4.0-15 O-Ring TaperLock Abutment 4.0-00 O-Ring TaperLock Abutment Long 4.O-Ring Abutments O-Ring TaperLock Abutment 1:1 Detail Drawing Part Name O-Ring TaperLock Abutment 4.0-00 O-Ring TaperLock Abutment 4. .O-Ring Receptor 1:1 Detail Drawing Part Name O-Ring Receptor Part Number 503-040-001 To keep O-Ring in position in the prosthesis O-Ring 1:1 Detail Drawing Part Name O-Ring Soft O-Ring Medium O-Ring Hard Part Number 503-504-001 503-504-002 503-504-003 Used with: 1 TaperLock Abutments 2 Superstructure bars 3 Q-Ring Low Profile Abutments Quantum BioEngineering.Fax: (954) 474-2533 10 .Tel: (800) 600-4845 . Ltd.Tel: (954) 474-2556 . 0-00 Abutment Long 5.Tel: (800) 600-4845 .Res-Q Low Profile System Res-Q Low Profile Abutment 1:1 Detail Drawing Part Name Res-Q Low Profile Abutment 5.Tel: (954) 474-2556 .0-15 Part Number 504-250-000 504-250-015 504-250-025 Res-Q Low Profile Res-Q Low Profile Abutment Long 5.Fax: (954) 474-2533 . .0-15 Res-Q Low Profile Abutment 5. Ltd.0-00 Part Number 504-150-000 504-150-015 504-150-025 Res-Q Low Profile Abutment 5.0-25 Same as above when longer abutments are needed (2mm longer) Res-Q Low Profile Retention Post 1:1 Detail Drawing Part Name Res-Q Low Profile Retention Post Part Number To be processed in the prosthesis for retention in conjunction with Res-Q Low Profile Abutments 504-000-000 Res-Q Low Profile Impression Post 1:1 Detail Drawing Part Name Res-Q Low Profile Impression Post Part Number 504-001-001 Res-Q Low Profile Impression Post Long 504-002-002 Transfer Impression Post for taking transfer impressions in conjunction with Res-Q Low Profile TaperLock Abutments Res-Q Low Profile Transfer Analog 1:1 Detail Drawing Part Name Res-Q Low Profile Transfer Analog Part Number Used as Transfer Impression Analog and as a processing analog with Low Profile Res-Q TaperLock Abutments 504-500-000 11 Quantum BioEngineering.0-25 Low Profile Free Standing Abutment for tissue supported prosthesis in cases of limited vertical dimension Res-Q Low Profile Abutment Long 1:1 Detail Drawing Part Name Res-Q Low Profile Abutment Long 5. .Res-Q 1:1 Detail Drawing Part Name O-Ring Soft O-Ring Medium O-Ring Hard Part Number 505-504-001 505-504-002 505-504-003 Used with Fixed Removable Abutments Quantum BioEngineering.Tel: (954) 474-2556 .Tel: (800) 600-4845 . Ltd.Fax: (954) 474-2533 12 . .Tel: (954) 474-2556 .Fax: (954) 474-2533 .0-00 Removable TaperLock Abutment 4.0-15 Removable TaperLock Abutment Long 4.0-15 Removable TaperLock Abutment 4.0-25 Part Number 502-140-000 502-140-015 502-140-025 Abutment to support bar restoration superstructure or for removable crown and bridge Removable TaperLock Abutment .Tel: (800) 600-4845 . Ltd.0-25 Part Number 502-240-000 502-240-015 502-240-025 Same as above when longer abutment posts are needed (2mm longer) Removable Coping Fixation Screw 1:1 Detail Drawing Part Name Removable Coping Fixation Screw Part Number 502-041-000 Holds the superstructure to Removable TaperLock Abutments Removable Casting Coping 1:1 Detail Drawing Part Name Removable Casting Coping Part Number 502-044-000 As a waxing sleeve for Removable TaperLock Abutments Removable Abutment Analog 1:1 Detail Drawing Part Name Removable Abutment Analog Part Number 502-400-000 For construction of laboratory models when using Removable TaperLock Abutments Removable Abutment Transfer Screw 1:1 Detail Drawing Part Name Removable Abutment Transfer Screw Regular Removable Abutment TransferScrew Long Part Number 502-001-001 502-002-002 Transfer Impression Post for taking transfer impressions of Removable TaperLock Abutments 13 Quantum BioEngineering.Long 1:1 Detail Drawing Part Name Removable TaperLock Abutment Long 4.0-00 Removable TaperLock Abutment Long 4.Bar Removable Abutments Removable TaperLock Abutment 1:1 Detail Drawing Part Name Removable TaperLock Abutment 4. . Fax: (954) 474-2533 . Ltd.Tel: (800) 600-4845 .5 Implant Mount Hex Transfer 4.Implant Mounts Implant Mount Hex Transfer 2:1 Color Coded Part Name Part Number Used to place implants either with Push-In or Thread-In Technique For transfer impressions Can be used as an abutment Implant Mount Hex Transfer 3. .0 960-135-200 960-140-200 960-150-200 Implant Mount Locking Screw 1:1 Detail Drawing Part Name Part Number To hold Implant Mount into position Implant Mount Locking Screw 600-111-000 Same as Abutment Holding Screw Implant Mount Transfer Screw 1:1 Detail Drawing Part Name Part Number Implant Mount Transfer Screw 960-001-001 As an extension screw to hold the Implant Mount for impression purposes and to prevent the impression material from going into the Implant Mount Implant Mount Impression Cap 1:1 Detail Drawing Part Name Part Number Used to cover upper opening of Implant Mount to prevent impression material from flowing inside the Implant Mount Implant Mount Impression Cap 960-002-002 15 Quantum BioEngineering.Tel: (954) 474-2556 .0 Implant Mount Hex Transfer 5. Implant Mount Hex Transfer 2:1 Color Coded Part Name Part Number Used to place implants either with Push-In or Thread-In Technique For transfer impressions Can be used as an abutment Implant Mount Hex Transfer 3.Fax: (954) 474-2533 16 .Tel: (954) 474-2556 .0 960-135-020 960-140-020 960-150-020 Implant Mount Locking Screw 1:1 Detail Drawing Part Name Part Number To hold Implant Mount into position Implant Mount Locking Screw 960-020-000 Same as Abutment Holding Screw Implant Mount Locking Screw 1:1 Detail Drawing Part Name Part Number To hold Implant Mount into position Implant Mount Locking Screw 060-020-111 Same as Abutment Holding Screw Quantum BioEngineering. . Ltd.0 Implant Mount Hex Transfer 5.5 Implant Mount Hex Transfer 4.Tel: (800) 600-4845 . Ltd.Fax: (954) 474-2533 . .50 650-001-001 650-002-002 Used as a Transfer Impression Post with One-Stage Healing Plug or One Stage Healing Cap Transfer Post .Implant Analogs and Transfer Components Transfer Post .35 600-001-001 600-002-002 Transfer Impression Post used with TwoStage Healing Cap Implant Analog 1:1 Detail Drawing Part Name Part Number Implant Analog 3.0 100-200-350 100-200-400 100-200-500 To transfer the position of the implant into the model Used with both TaperLock and Hex Abutments 17 Quantum BioEngineering.35 Transfer Post Two Stage Long .One Stage 2:1 Color Coded Part Name Part Number Transfer Post One Stage Regular .Two Stage 2:1 Color Coded Part Name Part Number Transfer Post Two Stage Regular .Tel: (954) 474-2556 .5 Implant Analog 4.0 Implant Analog 5.50 Transfer Post One Stage Long .Tel: (800) 600-4845 . 5-00 4.Fax: (954) 474-2533 18 . .5-25 505-145-000 505-145-015 505-145-025 Part Number Used as a FixedRemovable TaperLock Abutment with an O-Ring for retention when constructing a Fixed Removable Prosthesis Q-Fixed Removable Coping 1:1 Detail Drawing Part Name Part Number Q-Fix Removable Coping 4. Ltd. Prosthesis can be processed directly to the Coping or cast directly over the Coping O-Ring 1:1 Detail Drawing Part Name O-Ring Soft O-Ring Medium O-Ring Hard Part Number 505-504-001 505-504-002 505-504-003 Used with Fixed Removable Abutments • • • • • • Provides engagement for fixed crown and bridge Converts fixed prostheses into fixed detachable crown and bridge restorations Easy removal for routine maintenance Unique design with an O-Ring engagement Affordable and economic dental treatment Easy laboratory procedure Quantum BioEngineering.Tel: (800) 600-4845 .Q-Fixed-Removable C&B System Q-Fixed Removable C&B Abutment 1:1 Detail Drawing Part Name Q-Fix Removable Abutment 4.5 505-045-000 Used with Fixed Removable TaperLock Abutment.Tel: (954) 474-2556 .5-15 4. Ltd.50 2.Fax: (954) 474-2533 .Armamentarium Bone Harvesting Drills Part Name Part Number Bone Harvesting Drill Sizes: Starter Drill Pilot Drill 2.25 3.50 3.70 3.50 Bone Tap 4. .00 3.70 5.50 4.Tel: (800) 600-4845 .20 4.00 4.Tel: (954) 474-2556 .00 900-111-350 900-111-400 900-111-500 Drill Extender Part Name Part Number To extend drills when needed Drill Extender 900-111-000 19 Quantum BioEngineering.70 4.00 900-000-120 900-000-200 900-000-250 900-000-270 900-000-300 900-000-325 900-000-350 900-000-370 900-000-400 900-000-420 900-000-450 900-000-470 900-000-500 Used to drill the osteotomy and to harvest bone Bone Taps Part Name Part Number Used if necessary on D1 and D2 type bone for ease of placement of Thread Implants Bone Tap 3.00 Bone Tap 5. 00 3.70 5. Ltd.00 4.00 900-333-000 900-333-250 900-333-270 900-333-300 900-333-325 900-333-350 900-333-370 900-333-400 900-333-420 900-333-450 900-333-470 900-333-500 Used for the Bone Expansion Technique Osteotome Trials Part Name Part Number Osteotome Trial Sizes: 2.50 4.Fax: (954) 474-2533 20 .25 3.50 2.00 4.70 3.70 3.25 3.20 4.70 5.00 900-222-250 900-222-270 900-222-300 900-222-325 900-222-350 900-222-370 900-222-400 900-222-420 900-222-450 900-222-470 900-222-500 For shaping the osteotomy when doing the Bone Expansion Technique and Sinus Tap Also used for sizing and for meassuring the osteotomy Quantum BioEngineering. Osteotomes and Expanders Ergonomically designed Drill Caddy 900-900-000 Bone Expanders Part Name Part Number Bone Expander Sizes: Starter 2.70 4. .Drill Caddy (Not to Scale) Part Name Part Number To hold Drills.70 4.Tel: (800) 600-4845 .50 4. Taps.50 3.20 4.00 3.50 3.Tel: (954) 474-2556 .50 2. To assist when threading implant by pushing the driver with tip Carrier Wrench 902-903-000 21 Quantum BioEngineering.Tel: (800) 600-4845 .Fax: (954) 474-2533 . .Tel: (954) 474-2556 . Ltd.Implant Mount Carrier Part Name Part Number Implant Mount Carrier Insert Implant Mount Carrier Sleeve 902-333-000 902-444-000 For carrying and placing implants with both Thread-In and Push-In Techniques Implant Carrier Sleeve 902-555-000 For carrying and placing implants with Push-In Technique Implant Mount Carrier Assembly 1:1 Detail Drawing Part Number 1 To Thread-In or Push-In when using Implant Mount 902-345-000 2 To Push-In implant without Implant Mount 1 1 2 2 Carrier Wrench Part Name Part Number To loosen implant carrier when necessary. 10T Regular 6: Driver . Hex Holding Screw and Implant Mount Screw 5-6: Used to thread Removable Coping Fixation Screw 1: Driver .035 Regular 2: Driver .0.Ratchet Part Name Ratchet Torque Ratchet Part Number 903-001-001 903-002-002 Used with Drivers Thumb Knob 1:1 Detail Drawing Part Name Thumb Knob Part Number 903-000-001 Used with Drivers Drivers 2:1 Scale and 1:1 Detail Drawing Part Name Part Number 1: Implant Mount Driver Regular 2: Implant Mount Driver Long 3: Hex Driver . Ltd.0.Tel: (954) 474-2556 .Latch Long 903-001-011 903-002-011 903-001-022 903-002-022 Used to thread implants into the osteotomy Can engage: 1 The top of the Implant Mount 2 The Implant Mount Carrier 3 Threaded Knob 1 2 3 4 Drivers 2:1 Scale and 1:1 Detail Drawing Part Name Part Number 1-2: Used to thread Two-Stage Healing Cap 3-4: Used to thread One-Stage Healing Cap.50 Regular 4: Driver .Tel: (800) 600-4845 .Fax: (954) 474-2533 22 .10T Long 1 2 3 4 5 6 903-001-035 903-002-035 903-001-050 903-002-050 903-001-010 903-002-010 Quantum BioEngineering.Latch Regular 4: Hex Driver .50 Long 5: Driver .0. .0.035 Long 3: Driver . 0: Used to tap implants into place when using Implant Mount and to tap abutments into the implants ST: Implant Seating Tip 3. .5.Tel: (954) 474-2556 .5: Concave Seating Tip 4.Tel: (800) 600-4845 .0 5.4. Ltd.0 902-111-111 902-222-035 902-222-040 902-222-050 Handles (Not to Scale) Part Name Part Number Detail of Straight Handle Straight Handle 902-333-001 Part Number Detail of Offset Handle Offset Handle 902-333-002 Part Name Part Number Hex Handle 902-333-003 Detail of Hex Handle Rotating Handle Attachment 902-333-000 23 Quantum BioEngineering.Seating Tips Part Name Part Number Part Name Part Number ST: Used to tap implants into place 3.5 4.Fax: (954) 474-2533 .5 .0: Concave Seating Tip 5.0: Concave Seating Tip ST 3.0 . Tel: (800) 600-4845 . . Ltd.0 Sulcus Tap 5. when enough attached gingiva is present Sulcus Tap 2:1 Color Coded Part Name Part Number Sulcus Tap 3.0 903-333-035 903-333-040 903-333-050 To shape the crestal portion of the bone when placing TaperLock Abutments Wire Guide Part Name Part Number Used as a guide with Tissue Punch or Sulcus Tap Guide Wire 903-111-111 Quantum BioEngineering.5 Sulcus Tap 4.0 903-222-035 903-222-040 903-222-050 To expose the implant in the second stage (uncovering) surgery.0 Tissue Punch 5.5 Tissue Punch 4.Tel: (954) 474-2556 .Threaded Knobs Part Name Part Number Used with: Sulcus Reamers Tissue Punch Osteotome Trials Threaded Knob Regular Threaded Knob Long 902-000-001 902-000-002 Tissue Punch 2:1 Color Coded Part Name Part Number Tissue Punch 3.Fax: (954) 474-2533 24 . .Tel: (954) 474-2556 . abutment sitting. bone expansion and sinus tap Mallet 904-000-111 Abutment Pliers (Not to Scale) Part Name Part Number Abutment Pliers 904-000-222 To hold and place the abutments into position Nippers (Not to Scale) Part Name Part Number Nippers 904-000-777 Used to cut Two-Stage Healing Plug and for soft tissue contouring Depth Gage (Not to Scale) Part Name Part Number Used to measure the depth of the osteotomy and for probing the sinus membrane Depth Gage 904-000-333 25 Quantum BioEngineering.Tel: (800) 600-4845 .Fax: (954) 474-2533 . Ltd.Mallet (Not to Scale) Part Name Part Number Ideally balanced mallet for implant insertion. 662.472. Ltd. .7 KR Patent Number: 333231 Quantum BioEngineering.305 US Patent Number: 5.533.597.302.551.450 US Patent Number: 5.004 US Patent Number: 5.872 US Patent Number: 5.Fax: (954) 474-2533 26 .Tel: (954) 474-2556 .376.693 B1 AU Patent Number: 706046 CN Patent Number: ZL94195217.898 US Patent Number: 5.475 Part Name Part Number US Patent Number: 6.Tel: (800) 600-4845 .Needle Recapping Plier (Not to Scale) Part Name Needle Recapping Plier Part Number 904-000-444 Used as a pick-up plier or for OneHand OSHA Needle Recapping Technique Ronguer (Not to Scale) Part Name Part Number Ronguer 904-000-888 For shaping the thin crestal areas of the bone Bone Well (Not to Scale) Part Name Part Number Bone Well 904-000-555 For saving bone harvested with Bone Harvesting Drills and for mixing grafting materials US Patent Number: 5. 0 5.5 4.Tel: (800) 600-4845 .0 5.5 4. .0 5.5 4.Surgical Box (Not to Scale) Part Name Part Number Surgical Box 999-000-000 Ergonomically designed Surgical Box Surgical Box Layout 3.0 Note: There are no silicon inserts to prevent blood debris from accummulating 27 Quantum BioEngineering. Ltd.Tel: (954) 474-2556 .5 4.0 35 50 3.0 3.0 Designed to facilitate instrumentation during surgery and for sterilization purposes 35 50 3.Fax: (954) 474-2533 .0 5. Tel: (954) 474-2556 .Quantum BioEngineering. Ltd.Tel: (800) 600-4845 . .Fax: (954) 474-2533 28 . Bi oE Qu ng an ine tu eri m S 201 N ng Plauite 1 .F . (9 0) L 6 5 33 (95 4) 4 00-4 32 4) 74 84 4 47 -25 5 4-2 56 ww 53 w. co m . Univ Ltd (8 ntatio0n1 ersity Dr 0 . 3F qu an ax tu mi mp lan ts.
Copyright © 2024 DOKUMEN.SITE Inc.