Purelab Prima ELGA

March 29, 2018 | Author: Adi Pananta | Category: Water Purification, Electrical Connector, Ac Power Plugs And Sockets, Icon (Computing), Pump


Comments



Description

PURELAB Prima 7/15/20 Operator ManualINSTRUCTION MANUAL 312472452.doc Fisher Bioblock Scientific page 1 ator Manual ELGA TABLE OF CONTENTS 1. INTRODUCTION.........................................1 Product Range......................................................1 1.2 Use of this Manual.......................................1 1.3 Customer Support........................................1 2. HEALTH AND SAFETY NOTES......................2 2.1 Electricity.....................................................2 2.2 Pressure.......................................................2 2.3 Sanitization Chemicals.................................2 2.4 Control of Substances Hazardous to Health (COSHH) 2 3. PRODUCT AND PROCESS DESCRIPTION.......3 3.1 Product Description......................................3 3.2 Process Description......................................4 3.3 Technical Specifications...............................6 4. CONTROLS..............................................10 5. INSTALLATION INSTRUCTIONS..................11 5.1 Unpacking the PURELAB Prima...................11 5.2 Positioning the PURELAB Prima..................11 Connecting up the PURELAB Prima.....................13 5.4 Initial Controller Set-Up.............................15 5.5 Initial Start Up............................................17 OPERATION.....................................................18 6.1 Alarm Conditions.......................................18 7. MAINTENANCE........................................19 7.1 Replacing the LC140 Pre-treatment Cartridge 20 7.2 Cleaning the Inlet Strainer.........................21 7.3 Replacement of LC143 Reverse Osmosis Cartridge(s) 21 8. SANITIZATION PROCEDURES....................22 8.1 CT1 Sanitization Tablet - Safety Information23 9. TROUBLE SHOOTING...............................24 10. CONSUMABLES AND ACCESSORIES...........25 11. KEY TO CONTROL PANEL..........................26 11.1 Icons..........................................................26 11.2 Alarm Conditions.......................................26 11.3 Replacement Timers..................................26 11.4 Quality and Standby Alarms......................27 12. WARRANTY/CONDITIONS OF SALE............28 13. USEFUL ADDRESSES................................30 PURELAB Prima 7/15/20 Version 1 – 01/12/00 ELGA PURELAB Prima 7/15/20 Operator Manual 1. INTRODUCTION 1.1 Product Range This operator manual has been prepared for the PURELAB Prima product models: PURELAB Prima 7 PURELAB Prima 7 BP (with boost pump) PURELAB Prima 15 PURELAB Prima 15 BP (with boost pump) PURELAB Prima 20 PURELAB Prima 20 BP (with boost pump) 1.2 PURELAB Prima Use of this Manual This manual contains full details on installation, commissioning and operation of the PURELAB Prima unit. If this unit is used contrary to the instructions in this handbook, then the safety of the user may be compromised. 1.3 Customer Support Service support and consumable items are available from your local supplier or distributor. Refer to customer service contact details shown at the end of this publication. PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 1 Electricity It is essential that the electrical supply to the PURELAB Prima is isolated before any items are changed or maintenance work performed. ELGA HEALTH AND SAFETY NOTES PURELAB Prima products have been designed to be safe. WARNING! THIS APPLIANCE MUST BE EARTHED.PURELAB Prima 7/15/20 Operator Manual 2.1 WARNING! WARNINGS ARE GIVEN WHERE FAILING TO OBSERVE THE INSTRUCTION COULD RESULT IN INJURY OR DEATH TO PERSONS. A safety data sheet conforming to COSHH regulations is also provided with the tablets and should be read before the tablet is used.4 Control of Substances Hazardous to Health (COSHH) Material safety data sheets covering the various replaceable cartridges are available upon request. Contact your local supplier or distributor.2 Pressure The main water supply pressure should be isolated and residual pressure released prior to removal of any cartridges or carrying out work on the unit. 2. it is important that personnel working on these units understand any potential dangers.3 Sanitization Chemicals During the sanitization cycle a CT1 sanitization tablet is used and relevant safety information is included in this handbook. 2. Switching off the electrical supply will isolate the source of pressure. but pressure trapped within the unit should be released. Page 2 PURELAB Prima 7/15/20 Version 1 – 01/12/00 . however. All safety information detailed in this handbook is highlighted as WARNING and CAUTION instructions. The ON/OFF switch is located at the left-hand side of the unit. These are used as follows: Mains Power Supply 2. associated equipment and processes. 2. CAUTION! Cautions are given where failure to observe the instruction could result in damage to the equipment. The mains power lead is located just behind the ON /OFF switch. PRODUCT AND PROCESS DESCRIPTION 3.ELGA PURELAB Prima 7/15/20 Operator Manual 3. for detail ). – Consumables and Accessories.1 Product Description The PURELAB Prima water purification unit has been specifically designed to provide a supply of purified 'primary' grade water for laboratory. medical and industrial applications. The PURELAB Prima can be bench or wall mounted with an optional wall mounting kit. A range of accessories are available to complement the unit (see Section 10. PURELAB Prima PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 3 . PURELAB Prima 7/15/20 Operator Manual ELGA 3. and a  Temperature sensor which provides accurate temperature measurement.  The water then passes the sanitization port and through one. which measures the conductivity of the water. the purified water is delivered to a treated water reservoir. at 15°C and produces 7. which split the flow into permeate and concentrate streams.  Finally. A graphics screen displays the system status and provides control by means of three function buttons. or is pumped by means of a feed water pump (optional). The pre-treatment cartridge has been designed to protect the reverse osmosis cartridges from particulate/colloidal matter and excessive free chlorine.2 Process Description The PURELAB Prima process links two purification technologies. The unit is designed to operate from a good quality potable water supply. Page 4 PURELAB Prima 7/15/20 Version 1 – 01/12/00 .  The permeate water is passed through a  Water quality sensor. The water is processed and treated by the PURELAB Prima unit as follows:  Potable water enters through a strainer and inlet solenoid valve at either regulated mains water pressure. the unit has an in-built automated auto-rinse cycle. The permeate water is further purified whilst the waste concentrate stream is passed to drain. adsorption and also incorporates an optional RO feed water boost pump. which may be present in the incoming feedwater. 15 or 20 liters per hour of purified reverse osmosis grade water which is delivered to a treated water reservoir. two or three reverse osmosis cartridges. The auto-rinse cycle is performed every time the process is initiated and consists of a 1 minute high flow rinse to drain across the reverse osmosis cartridges. set up in series. and passes through the pretreatment cartridge. reverse osmosis.  To ensure that the quality of the purified outlet water from the unit is maintained at its highest level. PURELAB Prima PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 5 .ELGA PURELAB Prima 7/15/20 Operator Manual Reservoir Dispense Tap Process Flow . without internal boost pump 4.1") Width 410 mm (16. Temp 5-40°C.0 bar (30psi) 2.35ºC 1 . Clean dry indoor.maximum 0. Humidity max 80% non-condensing.35ºC 1 .5kg (28lb) 13.1") 460 mm (18. Humidity max 80% noncondensing. Temp 540°C.0 bar (60psi) Maximum . Clean dry indoor.5kg (32lb) 15.5kg (25lb) 12.with internal boost pump Flooded Suction Flooded Suction Flooded Suction Feedwater Pressure Dimensions Height 460 mm (18. Wall.0 bar (90psi) Minimum .0 bar (60psi) 4. Maximum during service 70 l/hr 70 l/hr 80 l/hr Maximum . bench or under bench mounted.05ppm 0.without internal boost pump 6.0kg (29lb) Weight Connections Inlet-quick connect 8mm (5/16") OD 8mm (5/16") OD 8mm (5/16") OD Outlet-quick connect 8mm (5/16") OD 8mm (5/16") OD 8mm (5/16") OD Drain RO-quick connect 8mm (5/16") OD 8mm (5/16") OD 8mm (5/16") OD Positioning Wall. Page 6 PURELAB Prima 7/15/20 Version 1 – 01/12/00 .6") 270 mm (10.0 bar (60psi) 4.6") With internal boost pump 13.0 bar (90psi) 6.2") 410 mm (16.0 bar (90psi) 6.0 bar (30psi) 2.5ppm 0.5ppm Heavy Metals . bench or under bench mounted.maximum 30ppm 30ppm 30ppm TEMPERATURE 1 .2") Depth 270 mm (10.05ppm 0.6") 270 mm (10.3 Technical Specifications The Technical Specifications for the PURELAB Prima are as follows: Feedwater PURELAB Prima 7 PURELAB Prima 15 PURELAB Prima 20 Feedwater Source Quality Potable mains water supply Potable mains water supply Potable mains water supply Fouling Index-maximum 10 10 10 Total Dissolved Solids-maximum 1400S/cm 1400S/cm 1400S/cm Free Chlorine-maximum 0. Environment Clean dry indoor.35ºC FLOWRATE (maximum requirement) 145 l/hr 150 l/hr 155 l/hr Drain requirements (gravity fall with air gap). Temp 5-40°C.0kg (33lb) Without internal boost pump 11. Humidity max 80% non-condensing.2") 410 mm (16.PURELAB Prima 7/15/20 Operator Manual ELGA 3.0 bar (30psi) Minimum .5kg (30lb) 14.5ppm 0.1") 460 mm (18. bench or under bench mounted.with internal boost pump 2. Wall.05ppm Silica . Graphical flow schematic on screen with mimic display. Intuitive Icons Adjustable settings Indicators Alarms-Audiovisual Outputs Auto restart after power failure Selectable Audible alarm Selectable Water purity Alarm setpoints Reverse osmosis permeate water conductivity Temperature Degrees centigrade Reservoir % Full Pre-treatment cartridge Maximum remaining life indicator Purified water purity Outside set point alarm Reservoir Low level Reservoir Level control disconnect alarm Pre-treatment cartridge Change reminder RS232 Printer connection RS232 Remote display connection Volt free contact-internal Safety Features Power fail safe Boost pump protection from particulates Low operating voltage 24V Audio visual alarms Adjustable alarm settings PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 7 . 50-60Hz all models System voltage 24 V dc Power consumption with boost pump 28 VA Power consumption without boost pump 52 VA Fuses 2 xT3.ELGA PURELAB Prima 7/15/20 Operator Manual Electrical Requirements Mains input 100-240V ac.5 mm Noise level <45 dBA User Interface Display Continuous graphical and numerical reservoir level display.15 Amp Reservoir level connection Jack Plug 3. Page 8 PURELAB Prima 7/15/20 Version 1 – 01/12/00 . Refer to flow tables outside these conditions. fed with potable water and a clean pre-treatment cartridge.PURELAB Prima 7/15/20 Operator Manual ELGA Special Features Low Noise Levels – minimum intrusion Flow rate upgradable Optional internal boost pump for low pressure feed waters Optional printer kit for record of operating parameters Optional remote display Technologies Purification Methods Adsorption Reverse Osmosis Purified Water Specification PURELAB Prima 7 PURELAB Prima 15 PURELAB Prima 20 *Make Up Rate 7.1 bar (1psi) 0. As part of our policy of continual improvement we reserve the right to alter the specifications given in this document.1 bar (1psi) Purity: Inorganic-minimum >90% rejection Inorganic-Typical up to 98% rejection Organics (MW>100 Dalton) >99% rejection Total Organic Carbon(TOC) typical <0.1 bar (1psi) 0.1 bar back pressure at 15 degrees centigrade.5 l/hr 15 l/hr 20 l/hr *Daily Output(nominal max) 180 l/24 hour day 360 l/24 hour day 480 l/24 hour day Output reverse pressure (max) 0.1 ppm **Bacteria <5CFU/ml Particles >99% rejection * Standard conditions are 4 bar inlet pressure. <0. ** Subject to correct operating and maintenance procedures. ELGA PURELAB Prima 7/15/20 Operator Manual PURELAB Prima Reverse Osmosis Capacity Charts Graph 1 .Nominal Flowrate vs Inlet Pressure for PURELAB Prima 7 Graph 2 .Nominal Flowrate vs Inlet Pressure for PURELAB Prima 20 PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 9 .Nominal Flowrate vs Inlet Pressure for PURELAB Prima 15 Graph 3 . Control Button PROCESS Control Panel Function Turns the process ON/OFF. Details of how to use the controls will be given in the appropriate sections.PURELAB Prima 7/15/20 Operator Manual 4. The PURELAB Prima control panel has a range of control icons as follows: BUTTON ICON LEFT DESCRIPTION Menu Scroll RIGHT Reset Mute Alarm Accept Printer Page 10 PURELAB Prima 7/15/20 Version 1 – 01/12/00 . ELGA CONTROLS The PURELAB Prima operates with a tactile membrane touch pad control panel which has a graphics display window and three program function control buttons. 2 Positioning the PURELAB Prima Before commencing with installation and operation of the PURELAB Prima unit. CAUTION! Note: If unit is to be wall mounted. please read and observe the following points. in a clean. PURELAB Prima unit.1 Unpacking the PURELAB Prima The following items should be supplied with your PURELAB Prima: 1. 2. as per IEC1010-1. Operator manual 4.ELGA PURELAB Prima 7/15/20 Operator Manual 5. If mounting the unit on the wall. INSTALLATION INSTRUCTIONS 5. Mains Lead 5. use the wall mounting kit and follow the instructions included in the kit. Environment The unit should be installed on a flat. Pollution Degree 2. PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 11 . dry environment. level surface. The unit can also be wall mounted against a vertical wall capable of supporting the weight (for this we recommend the use of the wall mounting kit Part No LA 610). Installation kit (LA513 or LA506) 3. ensure it is mounted on a substantial brick or concrete solid wall capable of supporting the operating weight of the system. noncondensating Unit Rear Mounting Points The unit is in Installation Category II. specifications for unit The unit is designed to operate safely under the following conditions:  Indoor Use  Altitude up to 2000 m  Temperature Range 5-40°C  Maximum Relative Humidity 80% @ 31°C decreasing linearly to 50% @ 40°C. Refer to weights. Feed Water Strainer PURELAB Prima Unit Installed with Storage Reservoir Page 12 PURELAB Prima 7/15/20 Version 1 – 01/12/00 .PURELAB Prima 7/15/20 Operator Manual ELGA Electrical The units can be connected universally to any electrical supply in the range of 100 . Feed Water The feed water should be of good quality and comply with specifications provided. Drain Electrical Connections A semi rigid flexible connection to a sink or suitable drain capable of handling at least 1. The mains lead is supplied with a molded plug on one end and a molded connector to the unit on the other. or above the unit. CAUTION! Operating with feed water temperatures outside the range from 1 to 35°C will cause damage to the PURELAB Prima unit. For pressurized feeds. and should be in the temperature range 1 to 35°C. to provide a positive flooded inlet pressure. LA 512). the minimum direct inlet pressure is 4.240 V and 50 60 Hz. The unit should be connected to an earth.5 l/min is required. This should enter the unit via an 8 mm (5/16") OD semi rigid tube. Reservoir feeds to the PURELAB Prima unit should be positioned at the same height. Higher feedwater pressures must be reduced using a pressure regulator valve (Part No.0 bar (60 psi) and maximum inlet pressure is 6 bar (90 psi). The drain point should have a gravity fall below the level of the unit and any connections direct to drain should have an air-break device fitted. 2. PULL out transit plug.ELGA PURELAB Prima 7/15/20 Operator Manual 5. PUSH in collet on connector. CAUTION! If the water supply is at a pressure greater than 6 bar (90 psi) fit a pressure regulator (LA 512). PUSH tube into connector. Outlet and Drain Connections 3. 4. Feed Water Inlet Connection Fitting tubes PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 13 . it should be connected as follows:  Mains water inlet tube  Drain  Outlet to reservoir Step 1 – Fitting Tubes 1. CAUTION! Do not restrict drain line.3 Connecting up the PURELAB Prima Once the PURELAB Prima unit has been positioned either on a wall or on a bench. CUT a clean square end on a 8 mm OD semi rigid drain tube. PURELAB Prima 7/15/20 Operator Manual ELGA Step 2 . Electrical Connections Step 3 . PLUG mains lead into mains socket.Connect High/Low Level Switch to Reservoir 1. PLUG mains lead into the socket on the left hand side of the PURELAB Prima unit.Connect Electrical Supply 1. INSERT jack plugs into the level control socket located at rear of unit and reservoir. Reservoir Level Connections Page 14 PURELAB Prima 7/15/20 Version 1 – 01/12/00 . 2. These are:1. Note: Always allow the initialization process to complete. When the PURELAB Prima unit is started for the first time after installation the following steps should be carried out to set up system preferences:Step 1 . PRESS the MENU button to go to the next screen to activate the set up menu sequence. causing it to sound.4 Initial Controller Set-Up The PURELAB Prima control panel is fitted with three control buttons. Start Up Screens A series of set-up screens will now be displayed. whilst it flashes the alarm icon. In manual mode the unit will remain in standby. These icons include:  A “scroll” icon indicated by an arrow  An “accept” button indicated by a tick  A “selection” icon indicated by a   Step 2 . Two software controlled touch pad buttons which are used to control set-up and process control functions. If auto restart is selected the unit will automatically restart after a power failure. switches the 2.Setting Up Menu Options SWITCH the mains power on to initialize the controller hardware set-up sequence. Audible Alarm Enable/Disable PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 15 . Select the option required using the button and accept with the  button. Select the option required using the button and accept with the  button.Audible Alarm Enabled/Disabled This display provides the option of either enabling the audible alarm. Auto/Manual Restart Step 3 . Various control icons are used to allow you to step through the set-up instruction process. The PROCESS button.Auto/Manual Restart This allows the selection of the AUTO/MANUAL restart option. which purification process ON and OFF.ELGA PURELAB Prima 7/15/20 Operator Manual 5. or disabling the audible alarm causing it to remain muted. This is indicated by the appearance of the MENU icon on the control screen. Purity Alarm Setting The following water purity alarm choices will be displayed. Press  to jump to the next consumable. To enter the replacement timer set up. Pre-treatment Cartridge Timer Step 2 . restart from the set up MENU and follow instructions from Step 1.PURELAB Prima 7/15/20 Operator Manual ELGA Step 4 . CAUTION! Before re-setting any of the cartridge timers. 100 µS/cm  50 µS/cm 20 µS/cm Select the alarm setting required using the and accept with the  button. A graphic of the pre-treatment cartridge and clock graphics are displayed with hourly timer status. . Press  to jump to the next consumable or to initiate reset. press the left hand touch pad button and at the same time turn the power on.Pre-treatment Cartridge Replacement Timer Setting this screen will cause the pre-treatment cartridge timer to reset to the preset value of 4380 hours (6 months). button Note: To reset any of the setup parameters.Report Printing (Only if connected to LA 618) To print a report press the Page 16 PURELAB Prima 7/15/20 Version 1 – 01/12/00 Autorinse icon. cartridge replacement (hours Step 3 .Accessing the Process On Display Screens The normal process screen will display newly installed SETUP preferences showing the following process information: Output water purity  Water temperature  Process mimic  Reservoir level  Scroll Process On  and Print icons You can scroll through the following display screens :  Pre-treatment remaining). Press  to reset timer or press to abort reset. Setting Up Display and Replacement Timers Turn the unit off at the power inlet module. ensure that the appropriate new cartridges have been installed and securely located correctly in the PURELAB Prima Step 1 . ELGA PURELAB Prima 7/15/20 Operator Manual PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 17 . which therefore initially both need to be directed to a drain or sink. the bacteriostatic solution will be rinsed from the unit. Turn on the feedwater supply to the unit and adjust the inlet pressure. The PURELAB Prima will operate on a feedwater pressure between 4. 5. press the PROCESS button to stop the unit. 7. The PURELAB Prima units are supplied containing traces of bacteriostatic solution which have to be rinsed out from the pipework and fittings. During this period. After 2 hours. 11. Where feedwater pressures are inadequate an internal optional boost pump should be fitted. 8.0 bar (90 psi). Page 18 PURELAB Prima 7/15/20 Version 1 – 01/12/00 and the water . The PURELAB Prima should be installed correctly as described in Section 5. 10. 3.5 Initial Start Up 1. Having checked that the water supply has been turned on. For critical applications the unit should be left to rinse overnight. press the PROCESS button and the unit will start. Turn on the electrical supply to the unit and switch the mains switch at the power inlet module on the left-hand side of the unit to the ON position. 6. DISCONNECT the outlet tube at the reservoir inlet and direct to a drain or sink. 4. 9. Check all hose connections are water-tight and that there are no leaks. Press the PROCESS button purification process will start.0 bar (60psi) and 6.PURELAB Prima 7/15/20 Operator Manual ELGA 5. The outlet tubing can now be reconnected to the reservoir. Leave the unit running for 2 hours to drain. The solution is rinsed through both the 'DRAIN' and 'OUTLET' tubes. 2. The unit has now been rinsed and is ready for use. Press the button to mute the audible alarm. 6. Follow the instructions to replace the pre-treatment cartridge (See Section 7.1). If water purity stays outside acceptable instructions contact your local supplier or distributor.1 Alarm Conditions Alarms will signal at the following conditions: Normal Process Screens Replace Pre-treatment Cartridge The pre-treatment cartridge replacement alarm is signalled by an audible alarm and flashing icon at the default setting of 4380 hrs (6 months) of use. Water Purity Alarm / Standby Reservoir Level Disconnect Alarm Reservoir Level Disconnect Fault Alarm The reservoir level disconnect fault alarm condition will signal with an audible alarm and flashing icon. PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 19 . PRESS the button to mute the alarm. until water purity improves to within acceptable purity limits. OPERATION The PURELAB Prima will run automatically and will signal alarm conditions to ensure prompt efficient system management and corrective action. This alarm condition will cause the process to turn off. Connect the reservoir level and press the process key to clear the alarm.ELGA PURELAB Prima 7/15/20 Operator Manual 6. Alarm Conditions Water Purity Alarm This alarm will signal if the water purity deviates from the preset parameters and will cause the water purity to flash. potable water with clean pre-filter. WARNING! ALWAYS CHECK THAT THE MAINS ELECTRICAL POWER AND FEED WATER SUPPLIES ARE SWITCHED OFF BEFORE ATTEMPTING TO CHANGE THE PURELAB PRIMA CARTRIDGE. ** Standard conditions are 4 bar (60psi) inlet pressure at 15° C. If further information is required on any aspect of maintenance please contact Customer Service. Identification of Consumable LC140 Pre-treatment cartridge The cartridge is accessible after opening the front door. PURELAB Prima – Replacement Cartridge Frequency of Consumable Replacement The following frequency of consumable replacement is recommended as a guide assuming typical usage.3 years (not an operator replacement item)** * These frequencies are only estimates and replacement will depend on the application and feed water quality.* Pre-treatment - LC140 max 6 months Reverse Osmosis -  Page 20 LC143 every 2 . RO boost pump (when fitted) the unit incorporates one strainer.PURELAB Prima 7/15/20 Operator Manual ELGA 7. MAINTENANCE Any maintenance work not detailed in this handbook should be carried out by an approved supplier or distributor. CAUTION! Ensure that the display and replacement timer settings are reset after replacing consumables. To protect the inlet solenoid valve. (Refer to section 5.4) PURELAB Prima 7/15/20 Version 1 – 01/12/00 . IDENTIFY the pre-treatment cartridge. 2. (LC140). 3. Step 2 . ENSURE pressure has dissipated from the unit by waiting a few minutes after switching off the power. 3. 2. REMOVE the reducing fitting from the top of the cartridge. REMOVE the reducing fitting from the elbow at the bottom of the cartridge. PRESS the PROCESS button to start the unit. 7. Location of Pre-treatment Cartridge Step 3 . Dispose of as ordinary waste. REFIT the reducing fitting from the elbow at the bottom of the cartridge by pushing the reducer into the elbow connector until locked and held by the retaining collet.4 – Setting Up Display Replacement Timers). REFIT the outlet tubing to the top of the cartridge. (See Section 5.Replacing the Pre-treatment Cartridge 1. UNPACK new cartridge and remove the two protective transit plugs sealing the inlet and outlet connection. by pushing back the retaining collet on the push fit connector and withdrawing the reducer. OPEN front door. PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 21 . 4. RESET pre-treatment cartridge timer. SECURE the new cartridge into its retaining clips ensuring the cartridge is the correct way up. observing all local and national regulations. CHECK the unit for leaks and close front door. REMOVE exhausted cartridge from retaining clips and discard. 2.Remove Pre-treatment Cartridge 1. 5. 5. and 6. Note: The consumable is non-hazardous.Switch Unit Of 1.ELGA PURELAB Prima 7/15/20 Operator Manual 7. 4.1 Replacing the LC140 Pre-treatment Cartridge The pre-treatment cartridge should indicated by the change reminder. be replaced when Step 1 . SWITCH the PURELAB Prima off at the power switch at the top left hand side of the unit. 7. ENSURE it is facing the correct direction (see diagram). 2. For information regarding the replacement of the LC143 reverse osmosis cartridge contact Customer Service. THE RO CARTRIDGES WILL THEREFORE REQUIRE RINSING PRIOR TO USE. REFIT tubes to inlet strainer. Step 1 . UNSCREW inlet strainer. 3. Replacement of LC143 Reverse Osmosis Cartridge(s) The reverse osmosis cartridge should be replaced if the permeate water purity or flowrate is not adequate and does not meet predicted or previous performance. 3. REPOSITION the inlet strainer. Step 3 . 2.Remove the Inlet Strainer 1. WARNING! ALL NEW RO CARTRIDGES ARE FILLED WITH A BACTERIOSTATIC SOLUTION TO PREVENT BACTERIAL CONTAMINATION DURING STORAGE.PURELAB Prima 7/15/20 Operator Manual ELGA 7.3 2. Page 22 PURELAB Prima 7/15/20 Version 1 – 01/12/00 . DEPRESS collars on both sides of strainer and disconnect tubing. 5. 4. ISOLATE inlet water supply. 4. 6.Replace the Inlet Strainer 1. REMOVE mesh filter. OPEN front door.Reassemble the Inlet Strainer 1. 4. Inlet Strainer SCREW up the inlet strainer. ENSURE it is facing the correct direction. INSERT mesh filter into strainer. 3.Dismantle the Inlet Strainer 1. Step 4 . REPOSITION the pre-treatment cartridge into its support clips. 2. HOLD inlet strainer over a sink or receptacle. CHECK mesh filter for signs of wear or damage. RE-ESTABLISH inlet water supply 5. REMOVE the inlet strainer from its position. REMOVE the pre-treatment cartridge from its clips and set aside to gain access to the inlet strainer. SWITCH OFF electrical supply. Step 2 .2 Cleaning the Inlet Strainer The Inlet Strainer should be checked and cleaned every six months to ensure that the strainer does not become clogged. replace or clean as necessary. TURN on power. TURN on power. INSERT CT1 cleaning tablet. The unit is sanitized to destroy the bacteria within the pipework. RECONNECT the outlet tube to the reservoir.Insert Tablet into Sanitization Port 1. 2. PRESS the PROCESS button to stop the process. REFIT cap on sanitization port. RESTORE the power. hand tight. 3. UNSCREW cap on sanitization port. 3. 6. SANITIZATION PROCEDURES The PURELAB Prima unit has a sanitization port which allows the sanitization agent to be introduced into the system in the form of a tablet. Step 4 . 2. 4. DISCONNECT outlet tube at the reservoir inlet and re-direct to drain.ELGA PURELAB Prima 7/15/20 Operator Manual 8. Sanitization may be required in the following circumstances:  Once a month to maintain low bacterial counts. 2. RELIEVE residual pressure in the system by waiting a few minutes after switching off the power.Return to Normal Operation 1. 3.  If the unit has not been used for a prolonged period of time. PRESS the PROCESS button to stop the process. and the filters of the unit. Recommended maximum frequency of cleaning once per month. CHECK the system for leaks. TURN electrical supply off. Step 2 . 2. TURN OFF the electrical supply. Please read this entire section to become familiar with the procedure before you start. PRESS the PROCESS button to start the process. 5. 3. PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 23 . ALLOW the sanitisation cycle to continue for 30 minutes.Start Sanitization Cycle 1. PRESS PROCESS button to return to normal operation. 4. Step 3 .To Start the Sanitization Process 1. Step 1 . Sanitization Port 4. ENSURE reservoir is less than 70% full of treated water. Spillages: If tablets are dry and uncontaminated collect up and place in heavy duty plastic bag. Wash away any residues with copious amounts of water. rest and expose to fresh air. water. Do not return to original container. used for sanitization applications. and is therefore toxic by inhalation. Note: A comprehensive Data Sheet is available on request and is supplied with each packet of tablets.wash out the mouth thoroughly with water and give large quantity of milk to drink. Wear protective clothing when handling. Toxicity: Serious risk of poisoning by inhalation or injestion. pH 6. In severe cases. Seek medical advice.1 CT1 Sanitization Tablet . Obtain medical advice.drench the skin with plenty of water. which rapidly dissolves in water. obtain medical attention and treat for acute chlorine poisoning. Hazard Assessment: Contains sodium dichloroisocyanurate dehydrate.Safety Information General Description: White solid tablet. obtain medical advice. Properties: Soluble in combustible. In severe cases. Inhalation . Skin . Mouth . First Aid: Eyes .thoroughly wash out with clean water for at least 15 minutes. Remove contaminated clothing and wash before reuse. Page 24 PURELAB Prima 7/15/20 Version 1 – 01/12/00 . Non- Handling Precautions: Keep container tightly closed in a dry place. eyes and respiratory system.remove from exposure.PURELAB Prima 7/15/20 Operator Manual ELGA 8. injestion and skin contact. Irritating to skin. The reservoir will automatically refill.0 . Fuse Removal Check the inlet strainer is clean (see Section 7. The alarm sound can be silenced by pressing the mute button. TROUBLE SHOOTING This section highlights the problems that can occur with the PURELAB Prima unit and how to rectify them.Connect High/Low Level Switch to Reservoir.Purity Alarms). Water purity alarm Check alarm set value is correct (see Section 5.4. Unit Noisy Open front door and secure pipework to stop vibration. Problems No display message Action Check mains supply and lead. Step 4 . Reservoir level disconnect fault alarm Check that the level controls are correct (see Section 5. Check feedwater supply. Check process mimic is showing reservoir filling.Useful Addresses).). If the unit cannot be repaired using this manual please call either your supplier or the local distributor.2 Cleaning Inlet Strainer).2 Positioning the PURELAB Prima Unit).1 Replacing the LC140 pre-treatment cartridge). Reservoir low level audible alarm sounds Press the crossed bell button to mute alarm. Check fuses in power inlet module and replace if blown.ELGA PURELAB Prima 7/15/20 Operator Manual 9. which details treated water output vs temperature and feedwater pressure. If problem persists then contact your local distributor. (See Section 13. PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 25 .3. then contact your local distributor. Output flow below specification. Check that the mains power is switched on. Pre-treatment cartridge replacement alarm Replace pre-treatment cartridge (see Section 7. Check supply pressure (see Section 5. The unit will normally sound an alarm and the respective icons will flash. Contact service technician to fit or replace booster pump(if fitted). Check RO flow-rate for the unit against the graphs shown in Section 3. If problem persists beyond that expected from normal operating conditions. Check connections to Reservoir.3 Step 2 . *** Required for optional pre-treatment filter housing (LA518). ** Required for reservoirs (LA611. Care should be taken to order the correct consumable items. Service Life* LC140 (Pre-treatment cartridge) 6 months 2 years LC143 (Reverse osmosis cartridge module) Typical life 2-3 years 2 years CT1 (Sanitization tablets) Typical usage 1 per month 2 years LC 136** (Composite Vent Filter) 6-months 2 years LC123*** (Pre-treatment Filter) 6-months 2 years * Service Life is an estimate only.PURELAB Prima 7/15/20 Operator Manual ELGA 10. CONSUMABLES AND ACCESSORIES Consumable Max. Accessory Page 26 Max. and will depend on the application and feed water quality. LA612. LA613). Shelf Life Cat No Installation kit LA513 Installation kit (with saddle valve) LA506 Pressure regulator valve (inlet) LA512 Pre-treatment filter housing LA518 Wall mounting kit (PURELAB Prima Unit) LA610 25 liter reservoir LA611 40 liter reservoir LA612 75 liter reservoir LA613 Wall mounting kit (25 & 40 Liter reservoir) LA591 Wall mounting kit (75 Liter reservoir) LA592 Flow upgrade kit (7-15 liter per hour) LA607 RS232 Printer kit LA618 RS 232 Remote display kit LA619 Chlorine test kit Test 30679 Docking Vessel – DV35 LA620 Pre-filter (if boost pump fitted) LA582 PURELAB Prima 7/15/20 Version 1 – 01/12/00 . 1 Icons Icon Description Mute Alarm Accept Scroll Auto Restart Manual Restart Set Up Menu Cursor Option Choice Cursor Selection Choice Cancel Reset Printer 11.4 PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 27 . KEY TO CONTROL PANEL 11.3 Replacement Timers Replacement Timer Pre-treatment cartridge Icon Preset 4380 hours ( = 6 months) 11.ELGA PURELAB Prima 7/15/20 Operator Manual 11.2 Alarm Conditions Icon Alarm Conditions Replace Pre-treatment Cartridge Reservoir Level – Disconnect Fault 11. 5 Quality and Standby Alarms Screen Description Process on and water purity alarm Standby and purity alarm Standby position Page 28 PURELAB Prima 7/15/20 Version 1 – 01/12/00 .PURELAB Prima 7/15/20 Operator Manual ELGA 11. EXPRESSED OR IMPLIED. or b) the 120th day following the date of shipment. incidental. BUT EXCLUDING MEMBRANES AND CARTRIDGES. Water System Limited Warranty Vivendi Water Systems Ltd warrants the water systems manufactured by it. Vivendi Water Systems Ltd shall not be liable for consequential. Representations. In the event of a breach of the foregoing warranty. VIVENDI WATER SYSTEMS LTD MAKES NO OTHER WARRANTY.ELGA PURELAB Prima 7/15/20 Operator Manual 12. any product or part thereof that proves to be defective in materials or workmanship within the warranty period. at its option. THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. oral or written. special or any other indirect damages resulting from economic loss or property damage sustained by any customer from the use of its products. The warranty provided herein and the data. Representations. provided the customer notifies Vivendi Water Systems Ltd promptly of any such defect. specifications and descriptions of the Vivendi Water Systems Ltd products appearing in Vivendi Water Systems Ltd’s published catalogues and product literature may not be altered except by express written agreement signed by an officer of Vivendi Water Systems Ltd. should not be relied upon. WARRANTY/CONDITIONS OF SALE ELGA is a trading name of Vivendi Water Systems Ltd. VIVENDI WATER SYSTEMS LTD MAKES NO OTHER WARRANTY. The exclusive remedy provided herein shall not be deemed to have failed of its essential purpose so long as Vivendi Water Systems Ltd is willing and able to repair or replace any nonconforming Vivendi Water Systems Ltd product or part. General Limited Warranty Vivendi Water Systems Ltd warrants the products manufactured by it against defects in materials and workmanship when used in accordance with applicable instructions for a period of one year from the date of shipment for the products. if given. specifications and descriptions of the Vivendi Water Systems Ltd systems appearing in Vivendi Water Systems Ltd published catalogues and product literature may not be altered except by express written agreement signed by an officer of Vivendi Water Systems Ltd. The warranty provided herein and the data. Vivendi Water Systems Ltd sole obligation shall be to repair or replace. against defects in materials and workmanship when used in accordance with the applicable instructions and within the operating conditions specified for the systems for a period of one year from the earlier of: a) the date of installation. EXPRESSED OR IMPLIED. oral or PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 29 . which are inconsistent with this warranty or such publications are not authorized and. THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. the information in this document is subject to change without notice and should not be construed as a commitment by Vivendi Water Systems Ltd.Vivendi Water Systems Ltd products”) are covered by the warranty. however. incidental. which are inconsistent with this warranty or such publications are not authorised and. Products or components manufactured by companies other than Vivendi Water Systems Ltd or its affiliates (“Non. Vivendi Water Systems Ltd hereby assigns to the purchaser any such warranty. however.VIVENDI WATER SYSTEMS LTD PRODUCTS ARE MERCHANTABLE OR FIT FOR A PARTICULAR PURPOSE. In no event shall Vivendi Water Systems Ltd be liable for incidental or consequential damages in connection with or arising from the use of this manual. if given. extended by the Product manufacturer. any product or part thereof that proves to be defective in materials or workmanship within the warranty period. at its option. In the event of a breach of the foregoing warranty. The exclusive remedy provided herein shall not be deemed to have failed of its essential purpose so long as Vivendi Water Systems Ltd is willing and able to repair or replace any nonconforming Vivendi Water Systems Ltd system or component part. special or any other indirect damages resulting from economic loss or property damage sustained by any customer from the use of its process systems. thereafter. labor cost shall be at the customer’s expense. NOTICE Vivendi Water Systems Ltd is constantly striving to improve its products and services.PURELAB Prima 7/15/20 Operator Manual ELGA written. Page 30 PURELAB Prima 7/15/20 Version 1 – 01/12/00 . Consequently. Vivendi Water Systems Ltd warrants its products against defects in materials and workmanship as described in the Warranty statement on the preceding pages. should not be relied upon. VIVENDI WATER SYSTEMS LTD EXPRESSLY DISCLAIMS ANY WARRANTY WHETHER EXPRESSED OR IMPLIED. if any. Also. Vivendi Water Systems Ltd sole obligation shall be to repair or replace. provided the customer notifies Vivendi Water Systems Ltd promptly of any such defect. Vivendi Water Systems Ltd assumes no responsibility for any errors that may appear in this document. Vivendi Water Systems Ltd shall not be liable for consequential. This manual is believed to be complete and accurate at the time of publication. The cost of labor for the first ninety (90) days of the above warranty period is included in the warranty. Vivendi Water Systems Ltd hereby assigns to the purchaser any such warranty. THAT THE NON . ELGA PURELAB Prima 7/15/20 Operator Manual 13.83 64 50 Ireland ELGA 127 Baldoyle Ind Estate Baldoyle Dublin 13 IRELAND Tel: +353 (0) 1 832 0035 Fax: +353 (0) 1 832 0038 Benelux ELGA Waterbehandeling B. Madrid SPAIN Tel: +34 (0) 91 660 4000 Fax: +34 (0) 91 666 7716 Nordic Region ELGA Box 8214 Domnarvsgatan 29 SE-163 08 Stockholm SWEDEN Tel: +46 (0) 8 587 663 00 Fax: +46 (0) 8 587 663 10 Other countries Tel: +44 (0) 1494 887 700 Fax: +44 (0) 1494 881 007 Visit our website at http://www.V. 7-11 Postfach 551 56235 RansbachBaumbach GERMANY Tel: +49 (0) 2623 891 0 Fax: +49 (0) 2623 891 220 USA USFilter 10 Technology Drive Lowell.com E-mail us on info@elgalabwater. Wattstraat 64 NL-2723 RD Zoetermeer NETHERLANDS Tel: +31 (0) 79 331 4100 Fax: +31 (0) 79 342 3707 Austria ELGA Triester Strasse 4a A-2353 Guntramsdorf AUSTRIA Tel: +43 (0) 2236 506003 Fax: +43 (0) 2236 50600322 Germany ELGA Krugbäckerstr. 6-8 Lyon Park Road North Ryde NSW.com PURELAB Prima 7/15/20 Version 1 – 01/12/00 Page 31 . USEFUL ADDRESSES UK ELGA High Street Lane End High Wycombe Bucks HP14 3JH UK Tel: +44 (0) 1494 887 700 Fax: +44 (0) 1494 881 007 France ELGA Immeuble Gay Lussac 20 Avenue G.elgalabwater. 2113 Sydney AUSTRALIA Tel: +61 (0) 2 8875 2800 Fax: + 61 (0) 2 8875 2700 Spain ELGA Poligono Industrial Santa Ana Electrodo 50-52 E-28529 Rivas-Vacias. MA 01851 USA Tel: +1 978 934 9349 Fax: +1 978 453 5821 VM: +1 978 458 0600 Australia ELGA Unit A1.Herriot 92350 Le Plessis Robinson FRANCE Tel: +33 (1) 40.83 65 00 Fax: +33 (1) 40. PURELAB Prima 7/15/20 Operator Manual Page 32 PURELAB Prima 7/15/20 Version 1 – 01/12/00 ELGA .
Copyright © 2024 DOKUMEN.SITE Inc.