Power Link G3Manual Ingles.

March 29, 2018 | Author: victorgaunamedellin | Category: Computer Network, Power Supply, Personal Computers, Switch, Lighting


Comments



Description

Square D® Powerlink® G3Lighting Control Systems Catalog Class 1210 07 CONTENTS DESCRIPTION PAGE WHY LIGHTING CONTROL? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SYSTEM ARCHITECTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 EMBEDDED WEB PAGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 CONFIGURATION SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SQUARE D® POWERLINK® G3 CONTROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . 10 SQUARE D® POWERLINK® G3 POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . 14 SQUARE D® POWERLINK® G3 CONTROL BUS . . . . . . . . . . . . . . . . . . . . . . . . . . 15 NETWORK AREA CONTROLLER (NAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 REMOTE SOURCE CONTROLLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 REMOTE MOUNT CONTROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 CONTENTS REMOTELY OPERATED ECB-G3 CIRCUIT BREAKERS . . . . . . . . . . . . . . . . . . . 21 Description Page NF PANELBOARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 DEVICE POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 DEVICE ROUTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 SELECTION - CATALOG NUMBERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 SYSTEM COMPONENT STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Square D ® Powerlink ® G3 Lighting Control Systems Why Lighting Control? WHY LIGHTING CONTROL? Lighting is the largest single consumer of electric power in a typical building, often exceeding 30% of the total energy cost. The main function of an intelligent lighting control system is to provide light, where and when it’s needed and to while reduce lighting in unoccupied areas. By controlling lights during non-occupancy periods, energy costs associated with lighting can often be reduced by over 50%. That’s why lighting control is so important. In addition, lighting control helps defer replacement costs of lamps and ballasts by reducing the number of annual burn hours. Many building codes now require the use of lighting controls to reduce energy consumption. Meeting such requirements, while still creating a comfortable and productive workspace, requires an intelligent lighting control system. The Solution—Square D ® Powerlink ® G3 For many designers, the engineering of a suitable lighting control system has become a daunting task. The designer must balance space constraints, equipment and installation costs, and maintenance and operational concerns, while ensuring a code-compliant installation. Fortunately, the Square D Powerlink G3 Lighting Control System is the solution for all of these concerns. This system addresses these concerns by: Square D® Powerlink® G3 Panelboard • Using standard lighting panelboards: Square D is the only manufacturer that offers a lighting control system that mounts in a standard lighting panelboard. All Square D Powerlink G3 components mount in the panel just like a standard circuit breaker. Documenting your control system layout is as simple as indicating which branch circuits are to be controlled. • Saving space: Since the lighting control system is located inside the lighting panelboard, valuable wall and floor space is available for more productive uses. Square D also offers space-saving, column-width panelboards and flexible modular panelboard systems. • Complying with codes: With today’s high available fault currents, it’s extremely important that your system meets code requirements. The Square D Powerlink G3 system is fully UL Listed and meets NEC 110.10 and 409 requirements. • Daylight Saving Time: Square D Powerlink G3 Controllers are designed with Daylight Saving Time (DST) feature to conform to local DST regulations. When the DST feature is enabled, one hour is automatically added to the current local time at 2:00 a.m. on the designated DST starting date. Similarly, one hour is subtracted at 2:00 a.m. on the DST ending date. 01/07 © 2007 Schneider Electric All Rights Reserved 3 Square D ® Powerlink ® G3 Lighting Control Systems Why Lighting Control? Choose Your System Capabilities The Square D Powerlink G3 product line offers a simple, cost-effective means for controlling branch lighting circuits. Four distinct systems provide a variety of capabilities to meet virtually any need. 500 Level System • Designed to be used in conjunction with other control devices such as: — External time clocks, access readers, occupancy sensors, or other building systems. • Control devices provide either dry-contact closures or digital serial communications. • Controller responds to commands from control devices by automatically switching a programmed group of lighting circuits. 1000 Level System • Includes all the features of the 500 level system. • Incorporates a flexible time scheduler that eliminates the need for external time clocks. Includes many control features not found in traditional, mechanical time clocks or energy management systems. — Features include: automatic daylight savings adjustments, sunrise and sunset tracking according to geographic location, and special events that run only on specific dates. • Ideally suited for stand-alone systems in retail, office, institutional, and industrial facilities. • Includes an optional Johnson Controls compatible N2 (JCI-N2) interface – — Johnson Controls Metasys ® certified controller provides many of the 1000 controller features. — Communicates directly with Johnson Controls Metasys or Companion devices. 2000 Level System • Combines the control, input, and scheduling features of the other systems with the added benefit of embedded Ethernet connectivity. — Provides control capabilities and communication with a true peer-to-peer (P2P) control network to allow different controllers to share input signals, schedules, and lighting zone states. • Ethernet connectivity reduces network installation costs and enhances reliability by eliminating the need for a dedicated lighting control network. — Ethernet infrastructure can also be more cost effective: it uses commonly available off-the-shelf components rather than manufacturer-specific proprietary components. — Enhanced system reliability: local IT staff can quickly diagnose and resolve most problems associated with the network infrastructure. 3000 Level System • Provides the foundation for web-enabled lighting control system. • Web-enabled benefits include: ability to override zones, change schedules, and view system status from the convenience of a standard web-browser. 4 © 2007 Schneider Electric All Rights Reserved 01/07 Square D ® Powerlink ® G3 Lighting Control Systems Why Lighting Control? Control Strategies All Square D Powerlink G3 systems offer a variety of control options to meet most lighting control strategies: • Space Control — Meet ASHRAE 90. and 3000 level controllers) — Provides blink notice to occupants prior to scheduled shutoffs and timed occupant override • Photometric Control — Photocells and daylight sensors can be connected to a Square D Powerlink G3 Controller inputs to switch zones in response to changing light levels — Daylight harvesting options for corridors. 2000. card access readers. Class 2 control wiring lowers overall system cost by eliminating costly conduit wiring runs and expensive 3-way and 4-way line voltage wall switches Square D Powerlink G3 systems accommodate a wide variety of control devices such as occupancy sensors. inputs from external building systems. 01/07 © 2007 Schneider Electric All Rights Reserved 5 . and 3000 controllers) — Optional support for Johnson Control N2 and BACnet protocols — Optional C-Bus™ Network compatibility with 3000G3C controller (device router required) Setup is easily accomplished. 2000. and photo sensors. — DMX512 protocol support for theatrical control applications (1000. lobbies. low voltage switches.1 Requirements: provides local space control interface with timed delay override — Low voltage. either from the keypad or from easy-to-use Windows-based software or browser. Class 2 wiring provides a power limited circuit in areas such as schools and correctional facilities where access to line voltage components presents a potential hazard • Occupancy Control — Wall and ceiling mounted occupancy sensors can be connected directly to the Square D Powerlink G3 Controller inputs — Reduces need for expensive slave packs to power sensors • Automatic Shutoff — Control branch circuits according to daily schedules (1000. — Low voltage. and atriums can also be easily accommodated • Digital Interface — RS-232 and RS-485 communications ports – supports industry-standard open Modbus® protocol — 10BaseT Ethernet port for 2000 and 3000 level controllers which supports open Modbus TCP protocol (Modbus standard supported by most manufacturers of building automation systems). Class 1 communications cable (Belden 27326 or equivalent). Subnet Communications • Each Square D Powerlink G3 Controller can directly operate up to eight control buses. • Controller signals the control buses to switch the associated branch circuits and polls each Square D Powerlink G3 Circuit Breaker to determine its actual status. • Slave panels (those containing control buses and remotely operated circuit breakers. Master Panel Slave Panel Slave Panel Subnet communications allow one controller to operate up to 168 remotely operated branch circuits. Master Panel 6 © 2007 Schneider Electric All Rights Reserved Slave Panels 01/07 . • Communications between the controller and the control buses are made with a 4-wire.Square D ® Powerlink ® G3 Lighting Control Systems System Architecture SYSTEM ARCHITECTURE Three levels of communications are provided that can be easily tailored to individual application requirements. but no controller) may be mounted up to 400 feet away from the master panel that contains the controller. • An automation level network can also be used to communicate with other building systems such as energy management systems and card access controllers. 2-wire. and zone status. master panels can share inputs. An RS-485 network consists of low cost. schedules. — Optional C-Bus™ Network capability with NF3000G3C controller and device router Ethernet Connectivity Square D Powerlink G3 2000 and 3000 level controllers have integrated onboard Ethernet capability.Square D ® Powerlink ® G3 Lighting Control Systems System Architecture Automation Network To the PC. Class 2 communications cable. Modem. Provides access up to 247 controllers using an RS-485 multi-drop configuration. The automation network uses widely accepted and supported industrial-proven protocols used by many building automation manufacturers and systems integrators Master Slave Slave Master Slave Slave Master Slave Slave — Modbus® ASCII/RTU open protocol in all Square D Powerlink G3 Controllers — DMX512 protocol in automation level network for theatrical lighting applications in 1000. 2000. In addition to providing high-speed Ethernet access. or Building Management System • Each controller provides both RS-485 and RS-232 serial ports. With 2000 and 3000 level systems. these controllers allow fast peer-to-peer (P2P) connectivity between panels. PC or Network Server Ethernet Cable 10 Base-T Network Hub or Router Ethernet CAT 5 Cable Controller’s Ethernet Port Power Supply Master Panel A Master Panel B Slave Panel Slave Panel 01/07 © 2007 Schneider Electric All Rights Reserved Slave Panel Slave Panel 7 . and 3000 level controllers — Optional JCI-N2 protocol for 1000 level controllers Automation networks provide remote access to the lighting control system over an RS-485 network. Belden 9841 or equivalent. the time clock. — Setup: A mimic screen of the controller allows remote access to a physical controller. firmware version. the current operating environment. and whether a circuit breaker is ON. and communications.Square D ® Powerlink ® G3 Lighting Control Systems Embedded Web Pages Monitoring page EMBEDDED WEB PAGES Access Square D® Powerlink® NF3000G3 level controllers from anywhere in the world! These controllers provide embedded web pages so you can control your lighting system over the web. The only requirement for web access is an Ethernet connection to the controller and Windows® Internet Explorer® (version 5. or tripped. Maintenance page — Diagnostics: Provides a panelboard summary that displays the panelboard address. or turn inputs ON or OFF. OFF.5 or greater). and the control bus firmware version. Also provides a controller summary that includes controller information including: model number. information includes the panelboard name. Typical Controller Home Page Enter the controller’s IP address in your internet browser. the control bus names. also provides options to command zone overrides ON or OFF. circuit breaker names. Diagnostics page In addition to the controller home page. zone. release zone overrides. input. there are five embedded web pages: — Monitoring: Contains detailed circuit breaker. schedule and remote source information for each panelboard. — Control: Provides much of the same information for zones and inputs as the “Monitoring” tab. circuit breaker numbers. Control page Click the buttons on the navigation bar to access any of the five embedded web pages. works just like the corresponding buttons on the real controller. the panelboard layout. — Maintenance: Provides product support and technical support contact information. the control bus model number. the current control bus operating state. Setup page 8 © 2007 Schneider Electric All Rights Reserved 01/07 . PCS also puts an entry in its event log. an e-mail can be sent. Multiple configurations can be conveniently stored to a workstation’s hard drive. view status. control inputs and zones of circuit breakers. and Use Square D® Powerlink® Controller Software to later uploaded to local or remote controllers. Users can view total ON time for any panel from within PCS. With the click of a mouse. a user can configure. users can quickly: — observe branch circuit status — examine system event logs — make configuration modifications — create or modify time schedules — initiate overrides • File Archiving: PCS gives administrators an extra level of comfort by providing the ability to back up system configuration files. • Alarm Setup: Increase uptime by receiving automatic e-mail notification when undesirable situations arise. and set lighting schedules—all from convenience of your laptop computer or desktop. When a load’s ON time exceeds a pre-set value. • Configuration Printing: Print out any configuration. Personal Computer Requirements The following are recommended minimum features for a PC that runs PCS software: • 300 MHz CPU • VGA graphics card and monitor (800 x 600 resolution recommended) • 60 MB free space on hard drive • Mouse or similar pointing device • Windows ® 2000 or XP ® operating system • RS-232 communications port • Ethernet interface card (optional) 01/07 © 2007 Schneider Electric All Rights Reserved 9 .Square D ® Powerlink ® G3 Lighting Control Systems Configuration Software CONFIGURATION SOFTWARE Square D® Powerlink® Controller Software (PCS) Square D Powerlink Controller Software (PCS) provides a simple and intuitive means for quickly configuring and monitoring the status of any Square D Powerlink G3 lighting control system. Benefits • Convenient Desktop Access: Eliminate costly downtime by using personal computers to access information. and control a lighting system from a local or remote workstation. With a click of the mouse. monitor. Use PCS software and 3000 level controllers to setup as many as five people to receive e-mails notifications about various conditions like: — non-responding circuit breakers — input changes — system operating changes • ON-time Reporting Setup: Quickly determine when to schedule re-lamping projects. With 3000 level controllers. and 3000 level controllers Controller operating programs and configurations are stored in non-volatile RAM. Each controller can control up to eight control buses connected to its subnet. Terminals on the controller allow connection to external control devices. convey circuit breaker and system status. even when the controller is removed from the panel. card access. For a complete discussion of inputs. and building automation systems. while the 1000. 2000. and 3000 level controllers) display for local setup and diagnostics. Typical control devices include low voltage pushbutton wall switches. The 500 level controllers can accept up to eight separate control inputs. Input types include: • maintained NO (normally open with or without blink) • maintained NC (normally closed with or without blink) • momentary toggle/maintained toggle • momentary on/momentary OFF • dual momentary Controller inputs can be configured for status feedback to operate pilot lights or actuate other control equipment. These devices monitor inputs. 2000. keys can be locked out via software command or by a password • convenient front panel RS-232 serial port for connecting a laptop computer to the system to download software or upgrade firmware LCD display: 1000. External Control Inputs Power supply Level 1000 controller mounted in the panelboard Square D Powerlink G3 Controllers accept commands from both dry-contact inputs and serial communications. refer to Data Bulletin 1210DB0001. The controller mounts in the panel interior across from the power supply and occupies the top three adjacent pole spaces. Typical Input Configurations for Square D ® Powerlink ® G3 Systems. All controllers provide 24Vdc control power (NEC Class 2) for sensing input contact status. LCD versions include a back-lit display for viewing in dark locations • front-panel keypad access to the configuration and system status. Input timers. 2000. and allow system configuration from the front panel keypads or through serial connection. occupancy sensors. 10 © 2007 Schneider Electric All Rights Reserved 01/07 . can also be incorporated into the input configuration to provide timed override control.Square D ® Powerlink ® G3 Lighting Control Systems Square D® Powerlink® G3 Controllers SQUARE D® POWERLINK® G3 CONTROLLERS Hardware Description LED display: 500 level controller Square D Powerlink G3 Controllers provide the interface and logic necessary for the operation of the entire control system. All Square D Powerlink G3 Controllers feature the unique ability to receive firmware upgrades without replacing programming chips. Firmware upgrades can be made locally or over the network. handle serial communications. with settings from 1 second to 18 hours. execute time schedules. and 3000 level controllers can accommodate either eight 3-wire or sixteen 2-wire inputs. ensuring the program will be retained. A total maximum current of 60mA at 24Vdc is available to eight status outputs. Controller features include: • an LED (500 level) or LCD (1000. photo sensors. Periods can be set to repeat every: Input terminals (typical for 1000. sentence-type programming screen for defining a logic expression for the zone. This type of configuration is ideal for interior lighting zones where a timed override is needed during non-scheduled time periods. LAST EVENT logic can be configured to determine how the zone will respond to a change in the state of a control source. and 3000 level controllers also provide a synchronization feature that allows inputs to be synchronized with other inputs. the configuration can be changed to an “AND” configuration for specific purposes such as disabling photo sensors during specific time periods.Square D ® Powerlink ® G3 Lighting Control Systems Square D® Powerlink® G3 Controllers Time Scheduler All 1000. By default. its commanded remote state will follow the “OR” status of the inputs. 01/07 © 2007 Schneider Electric All Rights Reserved 11 . 1000. and 3000 level systems include the ability to combine inputs with schedules to provide a powerful control solution. including configuration +/– offsets • unique network time synchronization service (2000 and 3000 level controllers). the controller is automatically synchronized by a network time server Logic for Control Sources Clock Zone State Input Clock Zone State Input Timer Input Clock Zone State Input Timer Clock Zone State Input/Clock configuration options for 1000 level systems showing OR and AND logic options (with and without input timers) The 500 level system allows multiple Square D Powerlink G3 circuit breakers to be programmed or “mapped” to a particular input. The clock circuit incorporates the latest technology to compensate for clock drift. each period can be set for a single event. time schedules. 2000. each with 24 ON/OFF daily periods • day-of-week calendar (7 day repeating) • special date periods. Capacitor backup ensures that the correct controller time is maintained during power outages for up to 30 days. by day or date — “n” days • sunrise/sunset tracking by geographic location (northern or southern hemisphere). and 3000 level controllers) — week. This keeps inputs in sync with one another and provides the ability to change the behavior of the switch. or to repeat perpetually. When a circuit breaker is shared between multiple zones. 2000. by day — month. allows different types of Boolean operators to be used together to determine how the zone will combine assigned sources. each zone has a dedicated input and time schedule configured for “OR” operation. Configurations of this type are extremely useful in egress areas where lighting is shared among different lighting zones. The 1000. Boolean combination logic. One input can control up to 168 circuit breakers connected to the system’s subnet. or zones. 2000. depending on the operating schedule. 2000. or COMBO logic. Up to 16 zones can be configured and independently controlled by either a dedicated input or time schedule. COM 1 The following time scheduling events are provided: • sixteen independent time schedules. Circuit breakers can be shared between inputs to create overlapping zone configurations. by day or date — year. to repeat over a specified period. The controller provides a simple. and 3000 level controllers feature a flexible on-board time scheduler. However. AL-CU RS232 COM 1 RS485 24 RX TX 12 8 7 6 5 4 3 2 1 © 2007 Schneider Electric All Rights Reserved 01/07 . The remote sources feature lets one controller share a control source from another controller in a peer-to-peer configuration. This auxiliary supply can furnish up to 100mA at 24Vdc. A source can be any schedule. any zone. Remote Sources Remote Sources is a unique feature available in the 2000 and 3000 level controllers. any input. This capability allows support for up to four user-selectable control sources per zone.Square D ® Powerlink ® G3 Lighting Control Systems Square D® Powerlink® G3 Controllers Variable Sources Both 2000 and 3000 level controllers have a variable source capability. A common application of the remote source feature is the sharing of an input. Listed below are a few common examples of how an input can be shared among 2000 or 3000 level controllers: • controllers sharing one input for a lighting zone served by multiple panels (example: a factory department with a local override) • controllers sharing multiple inputs to control a zone from multiple locations (example: gymnasium lights with a switch at each entrance) • all controllers sharing one input to control all zones (example: a contact closure from a security system or fire alarm) • controllers sharing one input to control selected zones (example: a cleaning crew switch in which half the lights come on) • control and annunciator panel that can control and show remote status of selected zones from multiple controllers (example: prisons) Auxiliary Power Auxiliary Power terminals All Square D Powerlink G3 controllers feature an auxiliary power post for powering external control devices. CLASS 2 / CLASE 2 / CLASSE 2 24V MAX. or any remote source. AND. NOR. double. + Not available with NF1000G3N2 controllers. LAST EVENT) Maximum remotely operated circuit breakers (per subnet) Blink notice (single.5mA maximum load per input terminal. NAND. XOR. delay no blink) ON-time Networking RS-232 port/RS-485 port Ethernet (10BaseT port) Protocols Modbus® ASCII/RTU Modbus TCP Johnson Controls N2★ DMX512 Front Panel LED display with cover Backlit LCD display Password or front panel disable System Level 500 1000 2000 3000 8 8 8 16 8 8 16 8 8 16 8 8 X X◆ X◆ X◆ X◆ X◆ X◆ — X◆ X◆ X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X — — — — — — — 16 24 X X X X — 16 24 X X X X X 16 24 X X X X X 64 — — 64 — — 64 32 256 64 32 256 64 1 64 2 64 4 64 4 — — X X 168 X — 168 X X 168 X X 168 X X X — X — X X X X X — — — X — X X X X — X X X — X X — X◆ — X X — X X — X X X X X X X X X X X + X + — — X X X — — X X X X X Memory Non-volatile memory for programs and configuration X On-board capacitor to power clock chip during power outage — Flash memory for firmware upgrade X Viewing Options Event Log — Strike Counter — Alarm viewing via Event Log — Alarm viewing via e-mail — Web-based setup. control and status monitoring — ▲ Terminals accept 24–18 AWG conductors. 01/07 © 2007 Schneider Electric All Rights Reserved 13 .Square D ® Powerlink ® G3 Lighting Control Systems Square D® Powerlink® G3 Controllers Controller Feature Comparison Feature Input terminals▲ 2-wire 2-wire with status feedback ▼ 3-wire Input Types 2-wire normally open (NO) or normally closed (NC) 2-wire NO or NC. ▼ 7. ◆ Requires PCS configuration software for setup. with automatic blink notification 2-wire maintained toggle 2-wire momentary toggle 2-wire momentary ON or momentary OFF 3-wire momentary Input timers (1 sec up to 18 hours) Input synchronization Sentry® Switch support On Delay/OFF Delay Time Scheduler Independent schedules ON-OFF periods/schedule 7-day 24-hour repeating schedule 32 special event/holiday periods Automatic daylight savings Sunrise/sunset with offsets Network time synchronization (requires TCP connection) Network Variables Communications inputs (network accessible) Remote sources (per controller) Maximum subscriptions Zones Maximum number Maximum sources per zone Configurable source logic (OR. XNOR. ★ Order NF1000G3N2 controller for use with Johnson Controls. the other supply furnishes the control bus and subnet with a 24Vdc.Square D ® Powerlink ® G3 Lighting Control Systems Square D® Powerlink® G3 Power Supply SQUARE D® POWERLINK® G3 POWER SUPPLY The Square D Powerlink G3 Power Supply provides power to operate the controller. Features • Attaches to panelboard interior. • External lead for connection to panel neutral. Class 1 source. This option is often used in applications where the system must remain operational during power outages. Power Supply • Modular connectors provide secure plug-in connections for connection to left-hand side control bus and controller. control buses. An optional type of power supply. is available for use with a separately derived primary power source. In such applications. • Low continuous power draw. • Internally self-protected against short circuits and electrical surges. and remotely operated circuit breakers. less than 20VA. The power supply attaches to an NF Panelboard interior in the same manner as a standard 3-pole circuit breaker. The controller is mounted adjacent to the power supply on the right-hand side. • Optional external leads for connection to remote power source. • Removable communication terminal block for making subnet connections. the external leads are connected to an uninterruptible power supply (UPS) or alternate power source. furnished with primary leads. the power supply is always located in the upper lefthand corner of the interior. The power supply derives its power from the panelboard interior bus and converts the line voltage into two separate supplies: one supply furnishes the controller with a 24Vdc. In 20-inch wide panels. Class 2 source. Power Supply Installed 14 © 2007 Schneider Electric All Rights Reserved 01/07 . occupies three adjacent pole spaces. • LED indication of Class 1 and Class 2 voltage sources operational status. Control Bus 01/07 © 2007 Schneider Electric All Rights Reserved 15 . If only one control bus is required. it is always mounted on the left-hand side of a standard panelboard or at the top of a column-width panelboard. Specifically. 2000). they distribute 24Vdc switching power and control signals to switch remotely operated circuit breakers and report circuit breaker status back to the system controller.Square D ® Powerlink ® G3 Lighting Control Systems Square D® Powerlink® G3 Control Bus SQUARE D® POWERLINK® G3 CONTROL BUS Control Bus Square D Powerlink G3 Control Buses provide the interface between the system controller and remotely operated circuit breakers. • LEDs to indicate operational status. Either one or two control bus strips can be mounted in a single panelboard. • Modular connectors provide secure plug-in connections for remotely operated circuit breakers and control electronics. Features • Attaches to NF Panelboard interior mounting rail (for NF panelboards manufactured after August 1. RJ-45 (1) RS-232 port. intuitive interface for creating schedules.6 mm) high x 2. the Internet.5 mm) deep Environment • • • Operating temperature: 32°F–122°F (0°C–50°C) Storage temperature: 32°F–158°F (0°C–70°C) Relative humidity range: 5%–95%. share data.2" (5. Features • Embedded RISC microprocessor platform with flash memory (no hard drives) • Liberal onboard I/O with six universal analog/digital inputs and four digital relay outputs • Integral web user interface to support many simultaneous users over the Intranet or Internet via a standard web browser • Cost effective for any size facility Technical Specifications • • • • • (1) 10/100 mbit Ethernet. RJ-45 (1) RS-485 port (1) LonWorks FTT-10 with Weidmuller connector (maximum 27 devices) Optional 56k modem. analog. 4/20mA current loop. non-condensing Communications Input/Output 16 © 2007 Schneider Electric All Rights Reserved 01/07 . With the Square D Powerlink NAC. observing critical loads. It features a compact embedded processor platform with flash memory to ensure data integrity. and host multiple simultaneous workstations connected over a local network. including I/O Battery is monitored and trickle charged Battery maintains processor for preset period then writes all data to flash Maintains clock for a minimum of five years Enclosure • • • NEMA Type 1 indoor use only Cooling: internal air convection 11" (279. or dial-up modem with optional internal autodial modem. issuing overrides.02mm) center Power Supply • • 120VAC. Lights can be monitored and controlled from any computer equipped with an Internet connection and a standard web browser. or its FFT-10 LonWorks ports. or pulse-type devices. Square D® Powerlink® Network Area Controller Large scale systems can readily be created by using multiple NAC controllers to manage global control functions. Users will appreciate the simple. there is no software to install or maintain. and viewing reports. The unit can be easily mounted directly to a wall or inside another enclosure. The NAC controller is ideally suited for commercial applications. RS-232/RS-485.Square D ® Powerlink ® G3 Lighting Control Systems Network Area Controller (NAC) NETWORK AREA CONTROLLER (NAC) The Square D® Powerlink® web-enabled Network Area Controller (NAC) harnesses the power of the Internet to provide a ready means for controlling and monitoring lighting and other loads within a facility.4 mm) wide x 14" (355. A single NAC controller can be used to support a variety of devices connected to its Ethernet. The NAC also boasts a full array of I/O capabilities for connection to dry-contact. 0 to 10V. RJ11 • • • (4) form C (SPDT) relay outputs rated for 240Vac/dc @ 2A resistive (6) universal inputs for Type 3 (10K) Thermistor.5" (63. or dry contact All I/O use screws terminals on 0. 50/6Hz 25VA maximum Battery Backup • • • • Provided for all functions. including multiple user accounts. Typical System Overview Page NAC403QS Features Features NAC403QS Password access 4 levels Floor plan depictions Optional Real-time status 32 zones Control overrides 32 zones Time scheduling Yes Holiday scheduling Yes Special event scheduling 32 zones Controller access (8) NF3000G3 Alarms Optional E-mail notification Optional Event log Yes Device Integration 01/07 Modbus ® TCP (8) NF3000G3 Modbus RTU integration Optional LonWork Integration Optional BacNet integration Optional C-Bus Network Integration 3000G3C (Device Router required) © 2007 Schneider Electric All Rights Reserved 17 . and integration with other control devices and systems. alarming functions.Square D ® Powerlink ® G3 Lighting Control Systems Network Area Controller (NAC) Quick Start NACs (NAC403QS) The quick-start configuration provides users with a low-cost web-enabled lighting control system. Designed to operate in conjunction with 3000 level systems. this “out of the box” NAC gives users essential lighting control features including global overrides and scheduling functions from the convenience of a standard web browser. custom report with custom graphical interfaces. Additional capabilities can be added. input synchronization. • Supports a wide variety of low-cost. this avoids pitfalls that are typically associated with daisy-chained network digital switches.4 mm) Mounting Wall mount COMMUNICATIONS Ethernet port (1) 10BaseT port INPUTS Inputs (16) dedicated 2-wire inputs or (8) 3-wire inputs Outputs (8) outputs (max of 60ma total for all outputs combined) Auxiliary power 24Vdc (100ma max) Terminal wire range #24-18AWG CONTROL POWER 18 Input voltage 120/240/277Vac Input power requirements 20VA max © 2007 Schneider Electric All Rights Reserved 01/07 .8 mm x 304. Features Square D Powerlink Remote Source Controller High Speed Connectivity • Ethernet communication eliminates bottlenecks typically associated with serial devices.Square D ® Powerlink ® G3 Lighting Control Systems Remote Source Controller REMOTE SOURCE CONTROLLER The Square D Powerlink Remote Source Controller (RSC) provides high-speed Ethernet connectivity that links a wide variety of input devices to a 2000 or 3000 level Square D Powerlink system. • Fully configurable from LCD display/keypad or via PCS software. • Uses existing LAN infrastructure to reduce input wiring cost. Any RSC input can be set up to control any remotely operated circuit breaker connected to the system. (8) 2-wire inputs with status output. or (8) 3-wire inputs. Powerful Control Capability • Supports (16) 2-wire inputs.8 mm x 152. • Provides an additional (16) independent time schedules that can be configured to operate any circuit breaker or zone configured on the system. • On-board auxiliary 24Vdc power supply powers external control devices. and programmable behavior according to specified time period. • Uses convenient radial feeds to independent input devices. Installation • NEMA Type 1 enclosure with knockouts • Integral 120 V power supply • UL listed 916 Energy Management Equipment Technical Specifications PHYSICAL CHARACTERISTICS Dimensions 12" x 12" x 6" (304. • Specifically designed to operate in conjunction with 2000 and 3000 level controllers. • Assignable input timers. easily replaceable input devices. 240 V. Square D Powerlink® electronics can be mounted externally to the panelboard. • Saves valuable circuit space: mounts on wall space next to any existing panelboard. • Power and Flexibility: add lighting control to any new or existing panelboard application. • Saves Time and Money: RMCs are easy-to-install for retrofit applications. RMCs are available with any Square D Powerlink G3 system — it’s the perfect fit. controller. RMCs include all the necessary hardware including enclosure. and power supply. • Compact dimensions–12 in. (305 mm x 305 mm x 152 mm) • Integral power supply for connection to 120 V. make the power connections. Maximum Sub-net Wiring Distance Nominal Voltage Power Supply Max Cable Length 120 V 400 ft (122 m) 240 V 400 ft (122 m) 277 V 400 ft (122 m) Features • NEMA Type 1 enclosure with hinged door for access to controller and connections. Simply mount the enclosure. They mount quickly and easily to reduce costly installation and downtime. All of the components are factory assembled and tested for proper operation. and connect a sub-net cable from the RMC to the Square D Powerlink G3 panelboards – it’s that easy. 01/07 © 2007 Schneider Electric All Rights Reserved 19 . x 12 in. • Full range of Square D Powerlink G3 controller options • UL Listed 916 Energy Management Equipment • Low power consumption – 20 VA max.Square D ® Powerlink ® G3 Lighting Control Systems Remote Mount Controllers REMOTE MOUNT CONTROLLERS With Remote Mount Controllers (RMC). RMCs are also useful in applications where access to panelboards is not permitted. freeing up valuable circuit spaces. and 277 V systems. x 6 in. Class 2 barrier kits. Square D ® Powerlink ® G3 Lighting Control Systems Remote Mount Controllers 4-wire. 18 AWG. 20 © 2007 Schneider Electric All Rights Reserved 01/07 . Connection from the RMC to the slave panel is made with a sub-net connection. subnet cable (General Cable 236100. or equivalent) Controller Slave panel – Slave panel Slave address selector in Slave panel 1 To next slave address selector Slave address selector in Slave panel 2 Square D Powerlink RMC Subnet Communications Wiring – When RMCs are used. Square D Powerlink G3 panelboards need to be configured as slave panels. Belden Cable 27326. subnet cable (General Cable 236100. Belden Cable 27326. or equivalent) Controller Slave bus interconnect cable Controller Power supply RMC Unit Slave bus interconnect cable Power supply in RMC unit B A + – A B B + A – + – + A B 4-wire. 18 AWG. Class 1 cable. Class 1 cable. • Contacts cannot be closed remotely when the handle is in the OFF position or the circuit breaker is tripped. allowing the circuit breaker handle to operate the contacts like a conventional circuit breaker. Without any restrictions. this superior capability assures the true status of the branch circuit is reflected back to the remote location. Circuit breaker handle Manual override Status flag • The thermal trip element – true RMS sensing and is calibrated to carry the continuous current rating of the circuit breaker at 40°C (140°F) free air ambient temperature. Tripping System with True RMS Sensing • Square D Powerlink ECB-G3 circuit breakers – have a permanent trip unit that contains a factory preset thermal (overload) trip element and a magnetic (short circuit) trip element in each pole.and 3-pole Square D Powerlink ECB-G3 Circuit Breakers. 1-pole ECB-G3 01/07 © 2007 Schneider Electric All Rights Reserved 21 . which means the circuit breaker will trip even though the operating handle may be restricted to the ON position. An internal crossbar provides common tripping of all poles on 2. and mechanical life. • Manual override selector located on the front of the circuit breaker – extremely useful when manual lighting control is critical or when a loss of control features occurs. electrical ratings. the motor drive train is disconnected from the contact. Operating Mechanism with VISI-TRIP® Indicator Square D Powerlink ECB-G3 circuit breakers have an over-center toggle mechanism that provides quick-make. The Best in Remote Operation ECB-G3 Series Bolt-on remotely operated circuit breakers • Robust 24Vdc motor and highly effective trip mechanism provide unequaled remote operation capability in terms of compact size. quick-break operation and the unique VISI-TRIP ® circuit breaker trip indicator. • In manual mode. • Contact status indication – provided by a sensing circuit that determines the presence or absence of voltage on the load side terminal of the circuit breaker.Square D ® Powerlink ® G3 Lighting Control Systems Remotely Operated ECB-G3 Circuit Breakers REMOTELY OPERATED ECB-G3 CIRCUIT BREAKERS Square D Powerlink G3 remotely operated circuit breakers are designed for installation in Square D NF Lighting Panelboards as part of the Square D Powerlink G3 Lighting Control System. The operating mechanism is trip-free. These circuit breakers provide the same overcurrent protection as found in standard circuit breakers. • In accordance with the National Electrical Code – Square D Powerlink ECBG3 circuit breakers are intended to be applied at up to 80 percent of their continuous current rating. • Motor and drive train can open and close the contacts when the circuit breaker handle is in the ON position. the operating handle moves to a position between ON and OFF when the circuit breaker is tripped. air-conditioning.Square D ® Powerlink ® G3 Lighting Control Systems Remotely Operated ECB-G3 Circuit Breakers Status flag Circuit breaker handle Oversize lug DC motor Control connector Bolt-on connections Circuit Breaker Interior Features • Overcurrent protection—UL Listed 489 • Series connected ratings up to 200.000 RMS symmetrical amperes • Integral ON/OFF/trip status position indicator. and heating.000 remote On/Off/On sequence of operations • Bolt-on line connectors • Oversized load lugs • Modular control connectors • UL Listed for high intensity discharge lighting (HID) • UL Listed switch duty rated (SWD). • Manual override • Rated for a full 200.12e 22 © 2007 Schneider Electric All Rights Reserved 01/07 . refrigeration rated (HACR) • Special emergency lighting option for meeting NEC 700. visible without removing trim. and National Electrical Code® (NEC) code compliance must all be considered when specifying a system. energy codes. Often.Square D ® Powerlink ® G3 Lighting Control Systems Remotely Operated ECB-G3 Circuit Breakers ECB-G3EL Remotely Operated Circuit Breakers for Emergency Lighting Circuits Identifying the proper controls for a lighting system can be a daunting task. It also provides a common handle tie to ensure that both circuits are manually switched together. 700. #14-8Cu per circuit. Both circuits are electrically tied to the same source via a single common bolt-on connection that receives its supply from the panelboard bus. The circuit breaker contains both a remotely operated switched circuit for controlling the luminaires. 14kA at 480Y/277Vac • Maximum Series Connected Ratings: 200KA at 240Vac and 100kA at 480Y/277V • Rated Endurance On/Off/On cycles: 200. and a manually operated unswitched circuit. These UL listed circuit breakers provide a means to comply with the requirements of the NEC. The circuit breaker provides a common trip function ensuring that both circuits will open whenever a fault occurs on either of the circuits.12(E). space considerations. which provides power to the unit emergency equipment’s charging and detection circuit. desired operation.000 operations • Breaker status viewing window for both circuits • Auto/manual override selector for the remotely operated circuit • UL listed Switch Duty Rated (SWD) and High Intensity Discharge (HID) ratings • Lug wire size: (1) #12-8Al. Square D Powerlink ECB-G3EL circuit breakers incorporate many of the same robust features as other Square D Powerlink ECB-G3 breakers including: • Handle Rating: 20A (both switched and unswitched circuits) • Maximum Voltage Rating: 480Y/277Vac • Interrupting Ratings: 65kA at 240Vac. controls for emergency lighting systems are also required which further compounds the complexity of the control system. Square D® Powerlink® ECB-G3EL Circuit Breaker for Emergency Lighting Circuits Both circuits of the ECB-G3EL breaker contain a thermal-magnetic trip mechanism that protects their associated conductors from overcurrent. Cost. 169°F (75°C) conductors • No breaker pigtails or other externally mounted hardware 01/07 © 2007 Schneider Electric All Rights Reserved 23 . Square D® Powerlink® ECB-G3EL circuit breakers relieve much of the burden associated with designing such control systems. H. This approach replaces the traditional method of independently mounting each panelboard and lighting control system. cost effective. This versatile lighting and power distribution panelboard features a wide selection of circuit breakers. and ready-to-install kits. saving valuable floor and wall space where tight equipment space is a concern. and enclosure space for field installed equipment. lighting contactors. and lighting control as offered with the MPS line. Square D has the expertise to integrate your requirements into one optimized. IPCs are Underwriters Laboratories (UL) Listed under file E83877 (Dead-Front Switchboard UL891). and motor starters. The following designs are available to suit your needs: • Standard —The NF Panelboard offers superior performance and application flexibility for commercial and industrial electrical systems up to 480Y/277V. • Column-width —These innovative panels are designed to fit into a standard size W. Modular panelboard systems are tailored to specifications and are available with a mix of Square D NQOD. In addition. Column-width panelboards can also be wall mounted. • Integrated Power Center (IPC) —This integrated system offers the wide range of factory assembled and wired panelboards interiors. as well as 200% rated neutrals for non-linear loads. or I-beam support columns commonly found in distribution and industrial facilities. which saves space and reduces installation time. Square D® Powerlink® G3 lighting control system installed in a column-width panel 24 © 2007 Schneider Electric All Rights Reserved 01/07 . All MPS panelboards are Underwriters Laboratories (UL) Listed under File E33139 (Panelboard UL67). accessories.Square D ® Powerlink ® G3 Lighting Control Systems NF Panelboards NF PANELBOARDS The NF Panelboard offers superior performance and application flexibility for commercial and industrial electrical systems up to 480Y/277V. NF Column-width and Square D Powerlink interiors. dry type transformers. transient voltage surge suppression (TVSS) units. Regardless of your system complexity. as well as optional power and control wiring. 5 and 12. the IPC offers factory installed and programmed building management systems. space saving solution. automatic transfer switches. factory assembled and wired integrated system. dry type transformers. NF. Square D is the only lighting control supplier that offers a full range of enclosure options including NEMA Type 3R. • Modular Panelboard Systems (MPS) —This panel system bundles electrical distribution equipment into a single. 8 in. Communication between the device router and the NF3000G3C controller is made with the included 50-foot serial cable. device power supplies will provide the current necessary for operating a variety of passive Square D® Clipsal® devices.8 in. (319mm) tall DEVICE ROUTER The Square D Powerlink Device Router allows the exchange of data between a Square D Powerlink NF3000G3C controller and Square D Clipsal devices. with cover • Unit and C-Bus Network communications LED indicators show the status of the line voltage and the network • Sources up to 700 mA (dual power supplies) to the C-Bus™ Network • 120V or 277Vac models available Square D® Powerlink® Device Power Supply • Dimensions: 8.9 in. A Square D Powerlink Device Power Supply consists of a Clipsal 8M enclosure containing one or two 4M Clipsal Power Supplies (120 or 277Vac).57 in. (319mm) tall 01/07 © 2007 Schneider Electric All Rights Reserved 25 . with cover • Unit. The device router consists of a Clipsal 8M enclosure containing a Clipsal PC Interface and a Clipsal Power Supply (120Vac or 277Vac). (97mm) deep x 12. Placed at critical points on the network. and C-Bus LEDs indicate the status of data transmission and power to the unit and the network Square D® Powerlink® Device Router • System network clock for synchronizing communications data • Network power source. Unit/Comms. This unidirectional device router receives data from Clipsal input devices such as keypads and touchscreens and sends data to Clipsal output devices such as relays and dimmers.Square D ® Powerlink ® G3 Lighting Control Systems Device Power Supply DEVICE POWER SUPPLY The Square D® Powerlink® Device Power Supply is used to distribute power on a C-Bus™ Network. • Surface-mount NEMA Type 1 enclosure. (226mm) wide x 3. (226mm) wide x 3. (97mm) deep x 12.57 in. • Surface-mount NEMA Type 1 enclosure. supplying up to 350mA • 120Vac or 277Vac models available • Dimensions: 8.9 in. This harness provides communications and power to the control bus. Slave bus connect harness Slave Bus Connect Harness Control bus subnet connection Address setting Control bus subnet 4-wire connection to master control bus and/or other slave panels Harness connection Slave Address Selector 26 © 2007 Schneider Electric All Rights Reserved 01/07 . The slave address selector plugs directly onto control buses . The harness contains modular plugs on each end. Features • Rotary operated switch labeled 0–7 for addressing panels • Removable terminal block for connecting subnet cable • Modular plug for connecting the Slave Address Selector to smart bus using the Slave Bus Connect Harness Slave Address Selector Slave Bus Connect Harness Assembly The Slave Bus Connect Harness assemblies are required in slave panels furnished with two control buses. The slave address selector establishes a unique system address for the panel that is both essential for system operation and useful when the system is accessed from a remote location.Square D ® Powerlink ® G3 Lighting Control Systems Accessories ACCESSORIES Slave Address Selector The Slave Address Selector is required for each slave panel connected to a subnet. NOTE: Every panel will require its own Slave Address Selector NFSELG3.Square D ® Powerlink ® G3 Lighting Control Systems Accessories Column-width Controller Cable A Column-width Controller Cable is required to connect the power supply to the controller when used in an NF Column-width Panelboard. This bracket is ideal for retrofit applications where all 42 circuit spaces in the panelboard are required for branch circuit breakers. If ordering the Remote Mounting Adapter. Remote Mounting Adapter Controller Front Panel Serial Cable The Controller Front Panel Serial Cable is used to make direct RS-232 connections from the controller to a PC or laptop computer. order power supplies with the (L) suffix. Communications to the Square D Powerlink G3 panels are made with a subnet connection. Column-width Controller Cable Remote Mounting Adapter The Remote Mounting Adapter provides a means for mounting the Square D Powerlink G3 panels with a controller and power supply in a separate enclosure. Serial Cable 01/07 © 2007 Schneider Electric All Rights Reserved 27 . Custom Barrier Kit Modem Kit This kit.Square D ® Powerlink ® G3 Lighting Control Systems Accessories Custom Barrier Kit The Custom Barrier Kit is an optional kit that provides a heavy-duty cable barrier at the panelboard entry and controller base. The kit includes: • MultiTech 33. contains all the necessary components for use with the controller.6 k Modem. which is designed specifically for Square D Powerlink G3 controllers. and instruction bulletin • Power supply • Square D® Powerlink® Modem cable Modem Kit RS-485/RS-232 Converter Kit The RS-485/RS-232 converter kit allows connection from the RS-485 port of the controller to the serial port of a personal computer. driver disk. No connectors are attached. Subnet Cable 28 © 2007 Schneider Electric All Rights Reserved 01/07 . RS-485/RS-232 Converter Kit Subnet Cable The Subnet Cable connects one controller to another in a subnet. Square D ® Powerlink ® G3 Lighting Control Systems Selection . PCS101 Software Catalog Number Description PCS101 Square D Powerlink Controller Software PCS101UP Square D Powerlink Controller Software Upgrade Controllers Catalog Number Description NF500G3 500 Level Square D Powerlink G3 Controller NF1000G3★ 1000 Level Square D Powerlink G3 Controller NF2000G3 2000 Level Square D Powerlink G3 Controller NF3000G3✝ 3000 Level Square D Powerlink G3 Controller ★ Add suffix N2 to controller catalog number for use with Johnson Controls. Power Supplies Catalog Number Voltage Rating (+/.Catalog Numbers SELECTION . ✝ Add suffix C to controller catalog number for use with C-Bus™ Network. Panelboard Catalogs Catalog Document Number Description 1670CT9601 NF & NF Column-Width Catalog 2010CT0001 Modular Panelboard Systems Catalog 2735CT0001 Integrated Power Center Catalog Selecting Square D® Powerlink® G3 System Components Select the catalog numbers appropriate for your system from the tables below.10%) System Voltage NF120PSG3L 110–120Vac 50/60Hz 120/240Vac 208Y/120Vac NF240PSG3 NF240PSG3L 220–240Vac 50/60Hz 380Y/220Vac 415Y/240Vac NF277PSG3 NF277PSG3L 277Vac 50/60Hz 480Y/277Vac Power Supply (Panelboard Bus Powered) Power Supply (Externally Powered) ➀ NF120PSG3 ➀ Power supply furnished with 50” (1270 mm) external power leads to connect to remote power source. 01/07 © 2007 Schneider Electric All Rights Reserved 29 .CATALOG NUMBERS Selecting Square D® Powerlink® NF Panelboards To select a panelboard for your lighting control system refer to the appropriate panelboard catalog listed below. 15A and 20A ECB-G3 have UL Listed SWD ratings. ◆ Satisfies requirements of NEC 700. and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers.12E. 65kAIR Catalog Number ● Three-Pole 480Y/277 Vac.8 AL or (1) #14 -8CU ● All ECB-G3 circuit breakers are UL Listed for use with HID lighting. as HACR type for use with air conditioning. Remote Source Controller Catalog Number Description Voltage RSC16G3120 RSC16G3240 120 Vac 16 input remote source control with enclosure and power supply RSC16G3277 240 Vac 277 Vac Remote Mount Controllers Catalog Number Controller Type Voltage RMC500G3120 RMC500G3240 RMC500G3277 500 120 Vac 240 Vac 277 Vac RMC1000G3120 RMC1000G3240 RMC1000G3277 1000 120 Vac 240 Vac 277 Vac RMC1000N2G3120 RMC1000N2G3240 RMC1000N2G3277 1000N2 120 Vac 240 Vac 277 Vac RMC2000G3120 RMC2000G3240 RMC2000G3277 2000 120 Vac 240 Vac 277 Vac RMC3000G3120 RMC3000G3240 RMC3000G3277 3000 120 Vac 240 Vac 277 Vac ECB-G3 Bolt-on Remotely Operated Circuit Breakers (UL Listed) 30 Ampere Rating One-Pole 277 Vac. heating. © 2007 Schneider Electric All Rights Reserved 01/07 . Occupies two pole spaces. 14kAIR 120 Vac. 14kAIR 240 Vac. ■ ECB32030G3 rated of 240V operation only—42kAIR. no device restriction NAC403QS Controller with quick-start station supports a maximum of (8) NF3000G3 controllers. 14kAIR 240 Vac. 65kAIR Catalog Number ● Two-Pole 480/277 Vac.Square D ® Powerlink ® G3 Lighting Control Systems Selection . 65kAIR Catalog Number ● 15 ECB14015G3 ECB24015G3 ECB34015G3 20 ECB14020G3 ECB24020G3 ECB34020G3 20 ECB142020G3EL◆ N/A N/A 30 ECB14030G3 ECB24030G3 ECB32030G3 ■ Lug Wire Size (suitable for use with 75C conductors) (1) #14 .Catalog Numbers Control Busses Catalog Number Total Spaces Panel Side NF12SBLG3 NF12SBRG3 12 Left Right NF18SBLG3 NF18SBRG3 18 Left Right NF21SBLG3 NF21SBRG3 21 Left Right Network Area Controllers (NAC) Catalog Number Description NAC403 Controller only. 3 Handle padlock attachment Slave Address Selector Catalog Number Description NFSELG3 Slave Address Selector Slave Address Assembly Catalog Number Description Slave Bus Connect Harness NF2HG3 Column-width Slave Bus Connect Harness Column Width Controller Cable Catalog Number Description NFCWG3 Column-width Controller Cable Remote Mounting Adapter Kit Catalog Number Catalog Number Description NFADAPTERG3 Remote Mounting Adapter Kit Front Panel Serial (RS-232) Cable Catalog Number Description NFFPCG3 RS-232 Serial Cable Custom Barrier Kit Catalog Number Description NFASBKG3 Custom Barrier Kit Modem Kit Catalog Number Description 6382G3MODEM Modem Kit RS-485/RS-232 Converter Kit Catalog Number Description 6382RS485G3KIT RS-485/RS-232 Converter Kit Subnet Cables Catalog Number Description NFSN06 6 ft (1. Maximum length available is 1000 ft (304.83 m) Subnet Cable NFSN10 10 ft (3. 2.Square D ® Powerlink ® G3 Lighting Control Systems Selection .Catalog Numbers UL Listed Mechanical Accessories Catalog Number Number of Poles Description HPAFD 1. © 2007 Schneider Electric All Rights Reserved 31 . where ( ) equals the number of feet required.05 m) Subnet Cable NFSN25 25 ft (7.24 m) Subnet Cable ➀ 01/07 Additional lengths available by ordering NFSN( ).62 m) Subnet Cable NFSN50 50 ft (15.8 m). Level 3 FCC Part 15. interconnection lines IEC 1000. Level 3 Electrical Surge Susceptibility. IBC.5 Molded Case Circuit Breakers Federal Specification W-C-375B/GEN. NFPA 5000. ASCE 7 32 © 2007 Schneider Electric All Rights Reserved 01/07 . Description NFDP1120G3C Single Supply 120V NFDP2120G3C Dual Supply 120V NFDP1277G3C Single Supply 277V NFDP2277G3C Dual Supply 277V SYSTEM COMPONENT STANDARDS Environmental Standards Operating Temperature (external panelboard ambient) 23°F to 104°F (–5°C to +40°C) Storage Temperature –4°F to 185°F (–20°C to +85°C) Operating Humidity 5% to 95% (non-condensing) ESD Immunity IEC 1000. Description NFDR120G3C 120V Device Router NFDR277G3C 277V Device Router C-Bus Network Power Supplies Catalog No. Class A Standards Controller Control Bus UL Listed 916 Energy Management Equipment UL Listed 916 Energy Management Equipment Meets NEC requirements for Class 1 control circuits Meets NEC requirements for maximum allowable gutter fill Power Supply UL Listed 916 Energy Management Equipment Meets NEC requirements for Class 1 and 2 control circuits Remotely Operated Circuit Breakers UL Listed 489 Molded Case Circuit Breakers NEMA Standard AB-1-1986 Canadian Standards Association (CSA) Standard 22. 12a. 13b Certifications 1000. Level 4 Electrical Surge Susceptibility. 11b. 2000. Class 11a. and 3000 Controllers California Title 24 Seismic qualified by ICC ES AC156 to seismic requirements of the following building codes and standard: UBC. and 13a.Square D ® Powerlink ® G3 Lighting Control Systems System Component Standards Selecting Square D® Powerlink® C-Bus™ Network Components C-Bus Network Device Routers Catalog No. 12b. Level 3 Electrical Fast Transient Susceptibility IEC 1000. power line IEC 1000. Level 4 RF Susceptibility IEC 1000. CBC. See the catalog reference table on page 29 for a list of these catalogs.5mA Max Per Input SW1 SW1 SW2 SW2 Control Wiring Class 2. Dimensions and wiring diagrams for panelboards can be found in the individual panelboard catalogs. Typical Low Voltage Input Connections Dual Momentary Toggle Momentary NO or NC Maintained Pushbutton Momentary Pilot Switch Pilot Device 24Vdc 7.Square D ® Powerlink ® G3 Lighting Control Systems Wiring Diagrams WIRING DIAGRAMS This section contains wiring diagrams for the Square D Powerlink G3 systems. #18–22 AWG 1000 ft (305 m) Max Various Low Voltage Switch Types Pilot Devices 24Vdc.5mA Max Inputs may share the common (+) 4 3 2 1 Control Wiring Class 2. 7. #18–22 AWG 1000 ft (305 m) Max (12) 4 (11) 3 (10) 2 (9) 1 Inputs may share the common (+) Typical Switch Types Wired in Parallel 01/07 © 2007 Schneider Electric All Rights Reserved 33 . 33 MA Typical Sensor Wiring Diagram 34 © 2007 Schneider Electric All Rights Reserved 01/07 .Square D ® Powerlink ® G3 Lighting Control Systems Wiring Diagrams CLASS 2 / CLASE 2 / CLASSE 2 24V MAX. #18–22 AWG 1000 ft (305 m) Max Power 24Vdc Power 24Vdc. #18–22 AWG 1000 ft (305 m) Max 1 2 3 4 5 Typical Photo Controller Wiring Diagram CLASS 2 / CLASE 2 / CLASSE 2 24V MAX. AL-CU COM 1 RS232 RS485 24 RX TX 8 7 6 5 4 3 2 1 Typical Controller 6 7 8 Typical Sensor Control Wiring Class 2. AL-CU COM 1 RS485 24 7 6 5 3 2 1 RS232 RX TX 8 4 Controller (Typical) Common Control Control Wiring Class 2. Square D ® Powerlink ® G3 Lighting Control Systems Wiring Diagrams Subnet 4-wire. Class 1 subnet cable. Class 1 cable. subnet cable (General Cable 236100. 18 AWG. or equivalent Slave Address Selector in Slave Panel 1 To next Slave Address Selector Slave Address Selector in Slave Panel 2 Subnet Wiring Detail Maximum Subnet Wiring Distances 01/07 Nominal Voltage Power Supply Power Supply Catalog Number Max Cable Length 120 V NF120PSG3 400 ft (122 m) 220 V NF240PSG3 100 ft (30 m) 240 V NF240PSG3 400 ft (122 m) 277 V NF277PSG3 400 ft (122 m) © 2007 Schneider Electric All Rights Reserved 35 . or equivalent) Slave Bus Interconnect Cable Controller Power Supply Master Panel Slave Panel Slave Panel Subnet System Communications Wiring + – A A + Power Supply in Master Panel B B A – B + A – + – B 4-wire. Belden Cable 27326. Belden Cable 27326. 18 AWG. General Cable 236100. 524 m) 5.Square D ® Powerlink ® G3 Lighting Control Systems Wiring Diagrams Automation Network Personal Computer or Modem RS-232 to RS-485 Converter RS-485 Daisy Chain.200 5.000 ft (1.800 5.524 m) 4.000 ft (1.000 ft (1.219 m) 3.219 m) 4.000 ft (1.000 ft (1.000 ft (1.000 ft (1. Twisted Pair Belden 9841 or equivalent Power Supply Controller Slave Panel Slave Panel Master Panel Slave Panel Slave Panel Master Panel Slave Panel Slave Panel Master Panel RS-485 automation level communications wiring Maximum Communication Cable Distances Maximum Distances Baud Rate 38.000 ft (1.000 ft (1.000 ft (1.000 ft (1.524 m) 5.400 36 1–8 Controllers 9–16 Controllers 17–32 Controllers 4.600 5.000 ft (914 m) 19.000 ft (1.524 m) 4.524 m) 5.524 m) 5.000 ft (1.524 m) 4.000 ft (1.524 m) 4. 2-Wire.219 m) 2.219 m) 1.400 5.219 m) © 2007 Schneider Electric All Rights Reserved 01/07 .219 m) 4.000 ft (1.219 m) 4.219 m) 9.000 ft (1.200 5.000 ft (1.524 m) 4. 3-wire.Square D ® Powerlink ® G3 Lighting Control Systems Wiring Diagrams RS-485 daisy chain. Belden 8723 or equivalent Note: RX = receive data TX = transmit data DTR = data terminal ready DSR = data set ready RTS = request to send CTR = clear to send DCD = data carrier detect RI = ring indicator GND = signal ground 5 Signal GND RX 2 2 RX 50 ft (15 m) max. 2-wire. Jumper on ECHO OFF Black/White Stripe 2-wire. TX 3 3 TX DTR 4 4 DTS DSR 6 6 DSR RTS 7 7 RTS CTS 8 8 CTS DCD 1 1 DCD (no connection) RI 9 RS-232 5 Signal GND Controller 5-pin Comms Terminal in Master Panel (1) RS-485 Cable DB9 Female COM 1 Controller 1 Controller 5-pin Comms Terminal in Master Panel (n) + + – – TX TX RX RX COM 1 Controller 2 9 RI (no connection) RS-232 controller serial connection detail to RS-485 01/07 © 2007 Schneider Electric All Rights Reserved 37 . twisted pair. RS-485 connection using a converter kit (catalog number 6382RS485G3KIT) RS-485 daisy chain. Belden 9841 or equivalent RS-485 Converter Comms Terminal RS-232 Female DB-9 Controller 5-pin Comms Terminal in Master Panel (1) Controller 5-pin Comms Terminal in Master Panel (n) Serial cable RS-232 Female COM 1 Controller 1 To Next Controller Master Panel COM 1 Controller 2 Power Supply Ground shield in one place only. twisted pair. Square D ® Powerlink ® G3 Lighting Control Systems Wiring Diagrams Ethernet Below are typical one-line diagrams for creating a local area network using the Ethernet capability of level 2000 or 3000 controllers. PC PC Remote Source Controller PC Network Area 3000 Controller 3000 Controller Typical Web-enabled System 38 © 2007 Schneider Electric All Rights Reserved 01/07 . PC or Network Server Ethernet Cable 10 Base-T Network Hub or Router Ethernet CAT 5 Cable Controller’s Ethernet Port Power Supply Master Panel A Master Panel B Slave Panel Slave Panel Slave Panel Slave Panel Typical Local Area Network Using Ethernet . Square D ® Powerlink ® G3 Lighting Control Systems Wiring Diagrams C-Bus Network Below are typical one-line diagrams for creating a local area network using the C-Bus Network capability of level 3000G3C controllers. Configuration Software C-Bus Toolkit—for C-Bus devices PCS101—for Powerlink controller Ethernet Powerlink Device Router PC Interface Power Supply RS-232 RS-232 WARNING: DO NOT CONNECT C-BUS NETWORK TO PC COMM PORT (RS232) N L USE COPPER WIRE ONLY Lighting Control Unit Comms Lighting Control RS-232 Unit C-Bus C-Bus PC Interface C-Bus CONNECTIONS Power Supply C-Bus CONNECTIONS C-Bus Device Network Powerlink G3 Hardware Burden Keypads Typical C-Bus Network Diagram 01/07 © 2007 Schneider Electric All Rights Reserved 39 . 1210CT0201R1/07 Replaces 1210CT0001R4/05 and all previous versions . and designs change from time to time.com 1210CT0201R1/07 Listed products must be installed/connected by licensed professionals only and used in compliance with applicable industry standards and/or installation regulations.Square D ® Powerlink ® G3 Lighting Systems Catalog Schneider Electric 295 Tech Park Drive LaVergne. please ask for confirmation of the information given in this publication.squaredlightingcontrol. TN 37086 USA 1-888-Square D (1-888-778-2738) 1-615-287-3400 www. As standards. Publishing: Square D Company Lighting Control Business Production: Square D Company Lighting Control Business 01/2007 © 2005 Schneider Electric All Rights Reserved Catalog No. specifications.
Copyright © 2024 DOKUMEN.SITE Inc.