Plc Keyence Kv-24r

May 22, 2018 | Author: lorenz012345 | Category: Programmable Logic Controller, Data Transmission, Computer Engineering, Technology, Computing


Comments



Description

KEYENCE KV Mode1. Overview This driver provides the software interface and communication protocol between XPanel and Keyence KV series PLCs. It supports the following families of Keyence PLCs. KV-10, KV-16, KV-24, KV-40 KV-300 with KV-L2 in KV mode 2. Communication Setup : XPanel (1) Create a new device. For creating a new device activate the menu ‘Tools’->’I/O Devices’ or bar. Following picture shows the first step of creating a new device. icon in tool- I/O Device Name Give a device name. This name will be used in the TAG configuration window of database accompanied by the ‘Station Name’. KEYENCE KV Mode - 1 2 . the ‘Station No’ field of below has to be assigned as the number of PLCs station number. Station Name Give a name to the PLC. The ‘Peer to Peer (1:1)’ can be chosen when the case of RS232C network. In this case. In this dialog box. select the ‘Device Type’ as ‘KEYENCE PLC (KV mode)’ and configure the proper serial communication parameters. Station Type Choose one of following two network types : Multi-Drop (1:n) Peer to Peer (1:1) The ‘Multi-Drop (1:n)’ can be chosen when the case of RS422/485 network. This name will be used in the database window accompanied with the ‘Device Name’. In this window.(2) Select a network type : ‘KEYENCE PLC (KV mode)’ After selecting the ‘OK’ button of previous step. KEYENCE KV Mode . all the connected PLC stations can be configured and registered to the XPanel. Each field can be configured with following rules. The ‘Station No’ field has no meaning in this network. ‘Serial Communication Configuration’ dialog box will be popped up as shown in following picture. (3) Create a station Move to the ‘Station’ tab of ‘Serial Communication Configuration’ dialog box. Only when there is data transmit (writing a TAG value to the station) error. the notification message is popped up.3 . Specify a decimal number between 0 and 9. Error Message Pop Up If this item is checked. KEYENCE KV Mode . Station No. Comm. This is effective only when the ‘Station Type’ of above is set as ‘Multi-Drop (1:n)’. XPanel displays a communication error notification message at every Rx and Tx error.Network ID This field has no effect. 32Bit Data Swap This field has no effect Using Checksum This field has no effect. This message box will be closed automatically about 5 seconds after. XPanel does not display the message at data receive error. 16Bit Data Swap This field has no effect. Otherwise(unchecked). Internal AUX.4 . FLOAT) data types are not supported. TAG Type Analog Digital [Symbol][Address] [Symbol][Address] Format Example DM0012 R0215 Address : decimal number Following table shows the list of devices which can be referenced in XPanel database. Address Notation The address of TAG in XPanel has the following format.3. Ensure that especially for using following functions of XPanel. Symbol CC CP C CTHC CTHP CTH CTCC CTCP CTC TC TP T TM DM R AT Description Counter : Current Value Counter : Preset Value Counter Contact High Speed Counter : Current Value High Speed Counter : Preset Value High Speed Counter : Contact High Speed Counter Comparator : Current Value High Speed Counter Comparator : Preset Value High Speed Counter Comparator : Contact Timer : Current Value Timer : Preset Value Timer : Contact Temporary Data Memory Data Memory Relay (I/O. Special AUX) Digital Trimmer Address Range 0-249 0-249 0-249 0-1 0-1 0-1 0-3 0-3 0-3 0-249 0-249 0-249 0 – 31 0 . Because of that. Recipe XY / SPC / Scope Trend KEYENCE KV Mode . double word (INT32.1999 0-17915 0-1 Type Analog Analog Digital Analog Analog Digital Analog Analog Digital Analog Analog Digital Analog Analog Digital Analog Access R/W R/W R/W R/W R R R R/W R/W R/W R/W R/W R/W R/W R/W R § Keyence KV mode protocol does not support block data read and write functions. UINT32. BCD32. UBCD32. 5 .4. KV-24. KV-40] [KV-L2 module of KV-300] KEYENCE KV Mode . KV-16. Communication Cable Wiring [KV-10. 6 .KEYENCE KV Mode .
Copyright © 2024 DOKUMEN.SITE Inc.