PC2800LR Generator Manual

March 22, 2018 | Author: Matt Robinson | Category: Gasoline, Battery Charger, Battery (Electricity), Methanol, Ac Power Plugs And Sockets


Comments



Description

2,800W DUAL VOLTAGE LONG RUN GENERATORPC2800LR If you are requested by the manufacturer to return the item for repair please complete the enclosed section and send it together with your product and your receipt (proof of purchase) to the service address shown below. Name: Address: User Guide & Warranty 2,800W DUAL VOLTAGE LONG RUN GENERATOR PC2800LR Contact Telephone No.: Email: Location of purchase: Fault Description: YEAR MANUFACTURER’S WARRANTY 3 In order to deal with your enquiry as quickly and efficiently as possible, we ask you to send your enquiry by email. Do not forget to include your name, address and a daytime telephone number. Alternatively, you can contact our freephone service hot-line on the number given below. Office hours are as follows: Mon - Fri: 8.00am - 6.00pm, Saturday 8.00am - 2.00pm & Sunday 10.00am - 4.00pm Omega Wolf Ltd Prospect Close, Lowmoor Business Park, Kirkby-In-Ashfield, Nottinghamshire NG17 7LF, UK. CUSTOMER HELPLINE UK / NORTHERN IRELAND 08707 323023 REPUBLIC OF IRELAND 1800 481 005 www.omegawolf.com/powercraft After Sales Support Now you have purchased a Power Craft product you can rest assured in the knowledge that as well as your 3 year parts and labour warranty you have the added peace of mind of dedicated helplines and email support. AFTER SALES SUPPORT UK / N. IRELAND HELPLINE NO 08707 323023 REP. IRELAND HELPLINE NO 1800 481 005 WEB SUPPORT: www.omegawolf.com/powercraft MODEL NUMBER: PC2800LR Product Description: 2. Keep your purchase receipt safe as proof of the date of purchase.. EN 12601:2001. The warranty certificate is only valid in connection with the receipt. 98/37/EC. provided that: .Repairs were not carried out by any other than the authorised workshop. EN ISO 3744:1995.800W DUAL VOLTAGE LONG RUN GENERATOR RRAN O NTH Congratulations! You have made an excellent choice with the purchase of this Quality product. This warranty does not affect your statutory rights. Please keep both in a safe place. in the form supplied by us. Ensure the product is sent well packed as no responsibility can be accepted for items lost or damaged in transit. address. Should you. UK / Northern Ireland 08707 323023 Web Support: www.com/powercraft Model Number: PC2800LR Rep. 36 Helpline No.omegawolf. EN 60204-1:1997 M D Irwin Quality Department 09/2007 WA WARRANTY CERTIFICATE Year of Manufacture 09/2007 2. defective devices can be sent FREIGHT PREPAID to the service address stated at the end of this booklet. contrary to expectations.Was not overloaded. Please include the following when sending in your product for repair: 1.800W DUAL VOLTAGE LONG RUN GENERATOR Model: PC2800LR Appropriate EC directives: 89/336/EEC. The product is guaranteed for a period of three years beginning on the day of purchase. Kirkby-In-Ashfield. This warranty certificate with your name. . Ireland 1800 481 005 02 Helpline No. Ireland 1800 481 005 27 S TY M . The receipt (proof of purchase) 2. contact details and a fault description completed overleaf. After the warranty has expired you can still send defective devices for repairs FREIGHT PREPAID to the address at the end of this booklet.Was not used with the wrong accessories.com/powercraft Model Number: PC2800LR Rep. experience defects due to material or manufacturing faults during private use within 36 months of the date of purchase we shall be liable for warranty in accordance with statutory warranty regulations. UK declare that the design and construction of the following machine. UK / Northern Ireland 08707 323023 Web Support: www. If the original receipt is not enclosed the repair will be charged for in all cases. We will. at our discretion either repair or exchange the device in accordance with warranty legislation. 2000/14/EC. The warranty does not affect your statutory rights. Our commitment to quality also includes our service.Contents 03 04 06 07 07 07 07 08 08 08 09 09 09 09 10 10 10 11 11 12 13 14 14 15 17 18 19 19 20 20 21 22 23 25 26 27 27 INTRODUCTION SAFETY COMPONENT IDENTIFICATION OPERATION Engine switch Recoil starter Fuel valve Choke rod Circuit breaker Ground terminal Oil alert system Pilot lamp DC Terminals DC Circuit Protector GENERATOR USE Connections to a Building’s Electrical System Generator Ground Circuit AC Applications AC Operation DC Operation Disconnecting the battery cables PRE-OPERATION CHECK Engine Oil Fuel Recommendation STARTING THE ENGINE STOPPING THE ENGINE MAINTENANCE Maintenance Schedule Engine Oil Change Air Cleaner Service Fuel Sediment Cup Cleaning Spark Plug Service TRANSPORTING/STORAGE TROUBLESHOOTING SPECIFICATIONS WARRANTY CERTIFICATE DECLARATION OF CONFORMITY Warranty EC DECLARATION OF CONFORMITY We OMEGA WOLF LTD.omegawolf. ISO 8528-10:1998. The guarantee period can only be extended for the duration of any repair required. . During the warranty period. comply with the requirements of the appropriate EC directives. 73/23/EEC In accordance with the standards: EN 55012 : 2002. Quotes as well as repairs after warranty period are to be paid for in all cases.The device was not put to any use other than the intended. Nottinghamshire. We hope you will enjoy using your purchase for many years to come.3A 1.omegawolf. UK / Northern Ireland 08707 323023 Web Support: www. Output (Watts) Phase Rated Voltage Rated Frequency DC Output Power Factor Engine Horsepower Rated Speed Displacement Ignition System Oil Alert System Starting System Oil Capacity (Litres) Fuel tank Capacity (Litres) Net Weight (kg) PC2800LR 2800 2500 Single 230V/110V 50Hz 12V 8.6 15 47kg Introduction Congratulations on choosing to buy a Power Craft product. All products brought to you by Power Craft are manufactured to the highest standards of performance and safety.com/powercraft Model Number: PC2800LR Rep.com/powercraft Model Number: PC2800LR Rep. This user’s manual describes the operation and maintenance of the Generator. UK / Northern Ireland 08707 323023 Web Support: www. By doing so you now have the assurance and peace of mind that comes with purchasing a product made by one of Europe’s leading manufacturers. Safety Message Your safety and the safety of others are very important. Ireland 1800 481 005 03 . Ireland 1800 481 005 26 Helpline No. Please read these messages carefully.0 Single cylinder 4-stroke air-cooled 6.7 3000rpm 200cc TCI Yes Recoil 0.omegawolf.Output (Watts) Cont. All information in this publication is based on the latest product information available at the time of printing.Specification MODEL Max. and. We have provided important safety messages in this manual and on the generator. are backed by our comprehensive 3 Year Warranty. We reserve the right to make changes at any time without notice and without incurring any obligation. Helpline No. as part of our philosophy for customer service and satisfaction. No part of this publication may be reproduced without written permission. • Be sure that anyone who operates the generator receives proper instruction.com/powercraft Model Number: PC2800LR Rep. Keep the generator dry.omegawolf. Ireland 1800 481 005 25 . UK / Northern Ireland 08707 323023 Web Support: www. Operator Responsibility • Know how to stop the generator quickly in case of emergency. Troubleshooting Helpline No. (See Page 18) • Understand the use of all generator controls. You can help prevent accidents by being familiar with your generator’s controls and by observing safe operating procedures. Using a generator or an electrical appliance in wet conditions such as rain or snow or near a pool or sprinkler system.com/powercraft Model Number: PC2800LR Rep. Read and understand this user’s manual before operating your generator. Do not connect to a building’s electrical system unless an isolation switch has been installed by a qualified electrician. Do not let children operate the generator. output receptacles and connections. UK / Northern Ireland 08707 323023 Web Support: www.Safety SAFETY INFORMATION Generators are designed to give safe and dependable service if operated according to instructions. Ireland 1800 481 005 04 Helpline No. could result in electrocution. or when your hands are wet.omegawolf. Do not connect to a building’s electrical system unless an isolation switch that has been installed by a qualified electrician. Keep the generator dry. UK / Northern Ireland 08707 323023 Web Support: www. Change the engine oil. or when your hands are wet. Crank the engine several revolutions to distribute the oil. 3. If the generator is stored outdoors. If you run the generator in an area that is confined. Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused.omegawolf. Storing the engine in this position will help to protect it from internal corrosion. Using a generator or electrical appliance in wet conditions. Ireland 1800 481 005 24 Helpline No. At this point. UK / Northern Ireland 08707 323023 Web Support: www. check all electrical components on the control panel. Be careful not to touch the silencer while it is hot. Moisture or ice can cause a malfunction or short circuit in electrical components. Do not enclose the generator in any structure. or near a pool or sprinkler system. Keep the generator at least 1 meter (3 feet) away from buildings and other equipment during operation. such as rain or snow. unprotected from the weather. Ireland 1800 481 005 05 . 2. Breathing exhaust can cause loss of consciousness and may lead to death. Drain the petrol into a suitable container. Helpline No.com/powercraft Model Number: PC2800LR Rep. Slowly pull the starter grip until resistance is felt. Perform this task in a well ventilated area with the engine stopped. the piston is coming up on its compression stroke and both the intake and exhaust valves are closed. Do not smoke or allow flames or sparks where the generator is refueled or where petrol is stored. The silencer becomes very hot during operation and remains hot for a while after stopping the engine. Safety Carbon Monoxide Hazards Exhaust contains poisonous carbon monoxide. Let the engine cool before storing the generator indoors. 4. provide adequate ventilation. Petrol is extremely flammable and is explosive under certain conditions. before each use. then reinstall the spark plug. and pour about a tablespoon of clean engine oil into the cylinder. Fire and Burn Hazards The exhaust system gets hot enough to ignite some materials. Remove the spark plug. Fuel vapours are extremely flammable and may ignite after the engine has started. Drain the carburetor by loosening the drain screw. or even partially enclosed. a colourless and odourless gas. Make sure that any spilled fuel has been wiped up before starting the generator. the air you breathe could contain a dangerous amounts of exhaust gas.Transporting / storage 1. Do not smoke or allow flames or sparks in the area during this procedure.omegawolf.com/powercraft Model Number: PC2800LR Rep. which could result in electrocution. Petrol is extremely flammable and is explosive under certain conditions. Refuel in a well-ventilated area with the engine stopped. could result in electrocution. To keep exhaust gas from building up. Keep flammable materials away from the generator. Do not operate the generator in rain or snow. Ireland 1800 481 005 23 . Fuel vapour or spilled fuel may ignite.Component Identification CHANGE OVER SWITCH 110V/230V ENGINE ON/OFF SWITCH VOLTMETER 110V OUTLETS 230V OUTLETS SILENCER FUEL METER FUEL TANK CAP Transporting / storage When transporting the generator. Record the engine number for your future reference. Let the engine cool before transporting or storing the generator.com/powercraft Model Number: PC2800LR Rep. Service according to the table below: STORAGE TIME Less than 1 month 2 months to 1 year RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Fill with fresh petrol and add petrol conditioner*. OIL DRAIN PLUG CIRCUIT BREAKER EARTH TERMINAL CHARGING LEADS AND CLIPS 1 year or more CHOKE LEVER FUEL ON / OFF VALVE AIR FILTER RECOIL STARTER * Use petrol conditioners that are formulated to extend storage life. Put a tablespoon of engine oil into the cylinder. Drain the carburetor float bowl. 2. Contact your authorised generator dealer for conditioner recommendations. turn the engine switch and the fuel valve OFF. Contact with a hot engine or exhaust system can cause serious burns or fires. Drain the fuel sediment bowl. Fill with fresh petrol and add some petrol conditioner*. Do not place heavy objects on the generator. Fill with fresh petrol and add some petrol conditioner*. Remove the spark plug. Change the engine oil. UK / Northern Ireland 08707 323023 Web Support: www. Drain the fuel sediment bowl.omegawolf. Ireland 1800 481 005 06 Helpline No. Be sure the storage area is free of excessive humidity and dust. After removal from storage.com/powercraft Model Number: PC2800LR Rep. Engine serial number: Helpline No. Keep the generator level to prevent fuel spillage. and fill with fresh petrol before starting. Before storing the unit for an extended period: 1. Take care not to drop or strike the generator when transporting. drain the stored petrol into a suitable container. UK / Northern Ireland 08707 323023 Web Support: www.omegawolf. Turn the engine slowly with the pull rope to distribute the oil. Reinstall the spark plug. Drain the carburetor float bowl. Pull the starter grip lightly until resistance is felt. MP340. The gap should be: 0. 4. When the valve lever is in the ON position. BPR6ES (NGK) MP240. tighten 1/8-1/4 turn after the spark plug seats to compress the washer. 2. BP6ES (NGK) To ensure proper engine operation.70-0. fuel is allowed to flow from the fuel tank to the carburetor. Remove the spark plug cap. 3. After the spark plug is seated. If the engine has been running. Visually inspect the spark plug.031 in) 6. Check that the spark plug washer is in good condition. 1. BPR5ES (NGK) MP270. Discard it if the insulator is cracked or chipped. 5. Switch position: OFF: To Stop the engine. ON: To run the engine after starting. Measure the plug gap with a feeler gauge.com/powercraft Model Number: PC2800LR Rep. If reinstalling a used spark plug. NOTICE The spark plug must be securely tightened. UK / Northern Ireland 08707 323023 Web Support: www. Clean the spark plug with a wire brush if it is to be reused. Use only the recommended-spark plugs or equivalent.Maintenance Spark Plug Service Recommended spark plugs: MP160. An improperly tightened spark plug can become very hot and could damage the engine. Operation Engine Switch To start and stop the engine. Return it gently to prevent damage to the starter. Ireland 1800 481 005 07 . tighten with a spark plug wrench to compress the washer. Never use spark plugs that have an improper heat range.omegawolf. Be sure to return the lever to OFF after stopping the engine. 8. the spark plug must be properly gapped and free of deposits. NOTE: Do not allow the starter to snap back against the engine.omegawolf. MP390. Correct as necessary by carefully bending the side electrode.If installing a new spark plug. then pull briskly. UK / Northern Ireland 08707 323023 Web Support: www. and thread the spark plug in by hand to prevent cross-threading. Ireland 1800 481 005 22 Helpline No. tighten 1/2 turn after the spark plug seats to compress the washer. Be careful Do not to touch the silencer.028-0. Helpline No. Use the wrench supplied in the tool kit to remove the spark plug.80 mm (0. Fuel Valve The fuel valve is located between the fuel tank and carburetor. the exhaust will be very hot.com/powercraft Model Number: PC2800LR Rep. Recoil Starter To start the engine. . Clean any dirt from around the spark plug base. com/powercraft Model Number: PC2800LR Rep. If the engine has not been run for a long time. Unsnap the air filter cover clips. lf the circuit breaker is switched OFF automatically. Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the socket. Clean the sediment bowl. Earth Terminal Fuel Valve Sediment Bowl DC Circuit Protector Earth Terminal The generator earth terminal is connected to the frame of the generator. Reinstall the air filter element and the cover. 2. remove the air filter cover. 3. Maintenance 1. AIR FILTER COVER CLIP CLIP AIR FILTER ELEMENT ELEMENT Fuel Sediment Bowl Cleaning The sediment bowl prevents dirt or water. 2. Turn the fuel valve to the OFF position. and filter in nonflammable or high flash point solvent. UK / Northern Ireland 08707 323023 Web Support: www. Ireland 1800 481 005 21 .com/powercraft Model Number: PC2800LR Rep. O-ring. 4.omegawolf. from entering the carburetor. 1. Soak the element in clean engine oil and squeeze out the excess oil. on a metal non-current carrying parts of the generator. Remove the sediment bowl. Wash the element in a solution of household detergent and warm water. or wash in nonflammable or high flash point solvent. 4. The engine will smoke during initial start-up if too much oil is left in the element. and sediment bowl. then rinse thoroughly. and remove the element. 3.Operation Choke Lever The choke is used to provide an enriched fuel mixture when cold starting. Fuel Filter O-Ring Circuit Breaker Sediment Bowl DC 12 Helpline No. and the earth terminals of each socket. check that the appliance is working properly and does not exceed the rated load capacity of the circuit before switching the circuit breaker ON again. which may be in the fuel tank. O-ring. The choke can be opened by moving the choke rod to the ON position and closed by moving the choke rod to the OFF position. and filter. the sediment bowl should be cleaned. O-ring.omegawolf. Reinstall the filter. Ireland 1800 481 005 08 Helpline No. Turn the fuel valve ON and check for leaks. UK / Northern Ireland 08707 323023 Web Support: www. Allow the element to dry thoroughly. Ireland 1800 481 005 09 . The battery must be connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and battery negative to the generator black terminal. Oil capacity: 0. Rapid engine wear will result. NOTICE Never run the generator without the air filter. Before the oil level in the crankcase can fall below a safe limit. Please dispose of used motor oil in a manner that is compatible with the environment. it is still advisable to thoroughly wash your hands with soap and water as soon as possible after handling used oil. Refill with the recommended oil and check the level. The terminals are coloured red to identify the positive (+) terminal and black to identify the negative (-) terminal. 2. We suggest you take it in a sealed container to your local service station or recycling centre for reclamation. Used motor oil may cause skin cancer if repeatedly left in contact with the skin for prolonged periods. oil filler cap. UK / Northern Ireland 08707 323023 Web Support: www. DC Terminals The DC terminals may ONLY be used for charging 12 volt automotive type batteries.6 Litres Operation Oil Alert System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Reinstall the drain plug and sealing washer. Pilot Lamp The pilot lamp is illuminated when the generator is operating normally. Tighten the plug securely.com/powercraft Model Number: PC2800LR Rep. and drain the oil. Although this is unlikely unless you handle used oil on a daily basis. Ireland 1800 481 005 20 Helpline No. 1.) DC Circuit Protector The DC circuit protector automatically shuts off the DC battery charging circuit when the generator is overloaded. service the air filter regularly.Maintenance Engine oil change Drain the oil while the engine is warm to assure rapid and complete draining. To prevent carburetor malfunction. DC Circuit Protector Circuit Breaker Earth Terminal DC 12 Helpline No.omegawolf. Using petrol or flammable solvent to clean the filter element can cause a fire or explosion.omegawolf. UK / Northern Ireland 08707 323023 Web Support: www. Do not throw it in the dustbin or pour it on the ground. Use only soapy water or nonflammable solvent. Service more frequently when operating the generator in extremely dusty areas. 3.com/powercraft Model Number: PC2800LR Rep. Air filter service A dirty air filter will restrict airflow to the carburetor. the Oil Alert system will automatically shut down the engine (the engine switch will remain in the ON position). Remove the drain plug and sealing washer. when there is a problem with the battery or the connections between the battery and the generator are incorrectly connected. make sure the area is well ventilated.Generator Use Connections to a Building’s Electrical System Connections for standby power to a building’s electrical system must be made by a qualified electrician. but only if it is required by local law or electrical code. Maintenance Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. If the engine must be run.com/powercraft Model Number: PC2800LR Rep. MAINTENANCE SCHEDULE (1) Service more frequently when used in dusty areas. UK / Northern Ireland 08707 323023 Web Support: www. Improper connections to a building’s electrical system can allow electrical current from the generator to back feed into the utility lines. (3) For frequent use. Shut off the engine before performing any maintenance.omegawolf. Before using the earth terminal consult a qualified electrician or electrical inspector for regulations. Improper connections to a building’s electrical system can allow electrical current from the utility company to back feed into the generator. Contact the helpline. Ireland 1800 481 005 10 Helpline No. Generator Earth Circuits Portable generators have a system earth that connects the generator frame components to the ground terminals in the AC output receptacles. or cause fires in the building’s electrical system. the generator may explode. The connection must isolate the generator power from utility power. log hours of operation to determine proper maintenance intervals. Ireland 1800 481 005 19 . and must comply with all applicable laws and electrical codes. The earth terminal can be used to earth the generator or bond the frame of the generator to the frame of a vehicle. UK / Northern Ireland 08707 323023 Web Support: www.com/powercraft Model Number: PC2800LR Rep. Perform the service and inspection at the intervals shown in the Maintenance Schedule below. Helpline No. (2) These items should be serviced by an authorised agent. burn. The system earth is not connected to the AC neutral wire. Consult the utility company or a qualified electrician. Such back feed may electrocute utility company workers or others who contact the lines during a power cut.omegawolf. When utility power is restored. Exhaust gas contains poisonous carbon monoxide. Disconnect DC battery charging cables. To stop the engine in an emergency. and determine whether the problem is the appliance. If an appliance begins to operate abnormally. Never exceed the maximum power rating of the generator. In an emergency: 1. Power levels between rated and maximum may be used for no more than 5 minutes. Disconnect the appliance. Ireland 1800 481 005 11 . Turn the engine switch to the OFF position. becomes sluggish or stops suddenly. DC Circuit Protector AC Operation 1. 2. 3. UK / Northern Ireland 08707 323023 Web Support: www. do not exceed the rated power.com/powercraft Model Number: PC2800LR Rep. If an overloaded circuit causes the AC circuit breaker to switch OFF. 4. Maximum power is: See specifications. In either case. but will shorten the service life of the generator. UK / Northern Ireland 08707 323023 Web Support: www.com/powercraft Model Number: PC2800LR Rep. Most motorised appliances require more than their rated wattage for startup. Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker OFF. 3. turn it off immediately. or if the rated load capacity of the generator has been exceeded. Ireland 1800 481 005 18 Helpline No. Appliance and power tool manufactures usually list rating information near the model number or serial number.omegawolf.omegawolf. See step 3. Switch ON the AC circuit breaker. Plug in the appliance. Make sure that it is in good working order. Make sure that the electrical rating of the tool or appliance does not exceed that of the generator. In normal use: 1. Faulty appliances or power cords can create a potential for electrical shock. For continuous operation. turn the engine switch to the OFF position. Rated power is: See specifications.Stopping the engine STOPPING THE ENGINE Generator Use AC Applications Before connecting an appliance or power cord to the generator. wait a few minutes and then reset the circuit-breaker. Turn the AC circuit breaker to the OFF position. Disconnect all electrical loads from panel receptacles. Helpline No. Start the engine. the total power requirements (watts) of all appliances connected must be considered. Turn the fuel valve to the OFF position. 2. Limit operation requiring maximum power to 5 minutes. reduce the electrical load on the circuit. NOTICE Substantial overloading will trip the circuit breaker. Circuit Breaker Earth Terminal DC 12 Do not exceed the current limit specified for any one socket. with recoil starter: Turn the engine switch to the ON position. Provide adequate ventilation when charging or using batteries. If the circuit protector continues to go OFF. Connect the negative (-) battery cable to the battery negative (-) terminal. Before connecting charging cables to a battery that is installed in a vehicle. 2. NOTE: To operate the battery charging facility. move the choke lever out of the OFF position. excessive current draw by the battery. 3. then pull briskly. Start the generator. Return it gently to prevent damage to the starter or housing.omegawolf. Connect the other end of the positive (+) battery cable to the generator positive (+) terminal. Turn the fuel valve to the ON position. Ireland 1800 481 005 17 . An overloaded DC circuit. Start the engine. Pull the starter grip lightly until resistance is felt. Charging will not occur unless this is done. Make sure to disconnect all electrical loads from panel receptacles. If you have manually closed the choke. 4. The vehicle or the generator may be damaged. or wiring problem will trip the DC circuit protector (PUSH button extends out). Starting the engine STARTING THE ENGINE 1. The automatic choke will be closed if the engine is cold. UK / Northern Ireland 08707 323023 Web Support: www. 5. disconnect the vehicle’s earthed battery cable. Connecting the battery cables: 1.com/powercraft Model Number: PC2800LR Rep. NOTICE Do not allow the starter grip to snap back against the engine. NOTICE Do not start the vehicle while the battery charging cables are connected and the generator is running. Connect the other end of the negative (-) battery cable to the generator negative (-) terminal. 3. flames and cigarettes away. discontinue charging and contact the helpline. The generator may be difficult to start if a load is connected. 4. UK / Northern Ireland 08707 323023 Web Support: www. DC Circuit Protector Circuit Breaker Earth Terminal DC 12 Helpline No. 6. 5. wait a few minutes before pushing in the circuit protector to resume operation. If you want to operate the choke manually.Generator Use DC operation The DC terminals may ONLY be used for charging 12 volt automotive-type batteries. it is necessary to switch the Circuit breakers to the off position. Ireland 1800 481 005 12 Helpline No. If this happens.com/powercraft Model Number: PC2800LR Rep. move it to the OPEN position as the engine warms up. keep sparks.omegawolf. 2. Connect the positive (+) battery cable to the battery positive (+) terminal. The battery gives off explosive gases. 6. Ireland 1800 481 005 13 . If you notice any undesirable operating symptoms.Pre-operation check Running the engine with persistent pinking is misuse. 7.omegawolf. UK / Northern Ireland 08707 323023 Web Support: www. Disconnect the other end of the positive (+) battery cable to the battery positive (+) terminal. These petrols are collectively referred to as oxygenated fuels. 4. Ethanol (ethyl or grain alcohol) Petrol containing more than 10% ethanol by volume may cause starting and/or performance problems. rubber and plastic parts of your fuel system. 3. Connect the vehicle earth cable to the battery negative (-) terminal. Disconnect the negative (-) battery cable from the generator negative (-) terminal. be sure its pump octane rating is 86 or higher. If you use an oxygenated fuel.com/powercraft Model Number: PC2800LR Rep. Methanol (methyl or wood alcohol) Petrol containing methanol must contain solvents and corrosion inhibitors to protect the fuel system. Disconnect the positive (+) battery cable from the generator positive (+) terminal. DC Circuit Protector Circuit Breaker Earth Terminal DC 12 Helpline No. Generator Use Disconnecting the battery cables: 1. Petrol containing more than 5% methanol by volume may cause starting and/or performance problems and may damage metal. Disconnect the other end of the negative (-) battery cable from the battery negative (-) terminal. Stop the engine. MTBE (methyl tertiary butyl ether) You may use petrol containing up to 15% MTBE by volume. Some states require this information to be posted on the pump. try to confirm the fuel’s contents.com/powercraft Model Number: PC2800LR Rep. UK / Northern Ireland 08707 323023 Web Support: www. Be careful not to spill fuel when filling your fuel tank. 5. Ireland 1800 481 005 16 Helpline No. switch to a conventional unleaded petrol. and the Manufacturer’s Warranty does not cover parts damaged by misuse. Before using an oxygenated fuel. Damage caused by spilled fuel is not covered under warranty. Oxygenated Fuels Some petrols are being blended with alcohol or an ether compound to increase the octane. 2. Reconnect the vehicle earth battery cable. NOTICE Oxygenated fuels can damage paint and plastic.omegawolf. Fuel system damage or performance problems resulting from the use of an oxygenated fuel are not the responsibility of the manufacturer and are not covered under warranty. 3. This is no cause for concern. NOTICE Running the engine with persistent pinking can cause engine damage.com/powercraft Model Number: PC2800LR Rep. Do not overfill the fuel tank (there should be no fuel in the filler neck). If the level is low. Check the fuel level gauge. 1. Avoid getting dirt or water in the fuel tank. Remove the oil filler cap and wipe the dipstick clean. Pre-operation check Fuel Recommendation 1. UK / Northern Ireland 08707 323023 Web Support: www. Refuel in a well-ventilated area with the engine stopped. Check the oil level by inserting the dipstick into the filler neck without screwing it in. Nondetergent and 2-stroke engine oils will damage the engine and are not recommended. Do not fill above the shoulder of the fuel strainer. all-temperature use.Pre-operation check Engine oil NOTICE Engine oil is a major factor affecting engine performance and service life. make sure the tank cap is closed properly and securely. SAE 10W-30 is recommended for general.com/powercraft Model Number: PC2800LR Rep. Pinking is a metallic tapping noise that can occur if poor or incorrect fuel is used or if the ignition timing is not set correctly. Refill the tank if the fuel level is low. Occasionally you may hear light sparks knocks or springing. UK / Northern Ireland 08707 323023 Web Support: www. Avoid repeated or prolonged contact with skin or breathing of vapour. KEEP OUT OF REACH OF CHILDREN. Do not smoke or allow flames or sparks in the area where the engine is refueled or where petrol is stored. under normal load. After refueling. fill to the top of the oil filler neck with the recommended oil. Be careful not to spill fuel when refueling. Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped. make sure the area is dry before starting the engine. (metallic rapping noise) while operating under heavy loads. Never use stale or contaminated petrol or oil/petrol mixture. Helpline No. Petrol is extremely flammable and is explosive under certain conditions. If any fuel is spilled.omegawolf. contact the helpline. Fuel tank capacity: 15 Litres FUEL TANK CAP FUEL STRAINER SHOULDER FUEL LEVEL GAUGE Use petrol with a pump octane rating of 86 or higher. Spilled fuel or fuel vapour may ignite. 2. If pinking occurs at a steady engine speed. Ireland 1800 481 005 15 . change brands of petrol.omegawolf. Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range. Ireland 1800 481 005 14 Helpline No. lf pinking persists. We recommend unleaded petrol because it produces fewer engine and spark plug deposit and extends exhaust system life. 2.
Copyright © 2024 DOKUMEN.SITE Inc.