Parker Hydraulic Accumulator Products HY10-1630

March 19, 2018 | Author: Yusuf Sukma Indriana | Category: Leak, Pump, Gas Technologies, Gases, Applied And Interdisciplinary Physics


Comments



Description

Hydraulic Accumulator ProductsCatalog HY10-1630/US BLADDER PRODUCTS Parker… Your Best Source for Hydraulic Accumulators! Parker is the leading manufacturer of hydropneumatic accumulators for industrial and mobile applications in North America. With over 50 years experience and one of the world’s broadest accumulator product offerings, Parker has the products and application expertise to be your best source for your next accumulator solution. Parker’s capabilities include: • Expanded product line to meet any application • In-house manufacturing capabilities • Exclusive in-house bladder molding facility • ASME approved and CE audited manufacturing plant • UL and FM approved manufacturing plant • Quick delivery response • National distribution network with factory trained sales representatives • Localized factory sales support • Application and engineering support • Worldwide capabilities • ISO 9001 Certified Large bore piston accumulators are machined on large capacity lathes. State-of-the art assembly cells allow for fast response to customer demands. Accumulator parts are manufactured in high-tech manufacturing cells. New products are designed utilizing the latest software technologies. Modern machining centers ensure highest quality accumulator parts. Parker’s in-house designed pre-charge machine ensures proper pre-charge regardless of ambient temperature. Every accumulator is cycle tested prior to shipment. Catalog HY10-1630/US Page Contents Hydraulic Accumulators Introduction 3000 Piston Sizing Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Bladder Accumulators – BA, BG, & BT Series ............................................................................................... 65-80 • Dimensions ........................................................................................................................................................................... 68 • Options ............................................................................................................................................................................. 74-76 • Ordering Information ......................................................................................................................................................... 78-79 Diaphragm Accumulators – AD Series ........................................................................................................... 81-86 • Dimensions ........................................................................................................................................................................... 83 • Options .................................................................................................................................................................................. 84 • Ordering Information .............................................................................................................................................................. 85 • Dimensions ...................................................................................................................................................................... 92-96 • Ordering Information .............................................................................................................................................................. 97 • Accessories ...................................................................................................................................................................... 98-99 Gas Bottles – GB Series ............................................................................................................................. 101-104 Accumulator Accessories ........................................................................................................................... 105-114 • • • • • Charging & Gauging Assemblies .................................................................................................................................. 106-111 Unloading Valves ................................................................................................................................................................. 111 Bladder Accumulator Repair Tools ....................................................................................................................................... 112 Port Adaptors ...................................................................................................................................................................... 112 Mounting Accessories & Brackets ................................................................................................................................. 113-114 • Dimensions .................................................................................................................................................................. 126-127 • Options & Ordering Information ........................................................................................................................................... 128 Model Number Cross Reference ................................................................................................................. 187-200 Offer of Sale ........................................................................................................................................................ 208 ! WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having expertise. It is important that you analyze all aspects of your application, including consequences of any failure and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its related companies at any time without notice. © Copyright 2003, Parker Hannifin Corporation. All rights reserved. 1 Cross Maint. Reference SurgeKushons • • • • • • • Hydraulic Piston Accumulators ..................................................................................................................................... 141-146 Hydraulic Piston Accumulators – CE Marking ............................................................................................................... 147-156 Bladder Accumulators .................................................................................................................................................. 157-164 Bladder Accumulators – CE Marking ............................................................................................................................ 165-178 Diaphragm Accumulators ............................................................................................................................................. 179-182 Inline Pulse-Tone™ ...................................................................................................................................................... 183-185 Gas Chucks ......................................................................................................................................................................... 186 Kleen Vent Sizing Data .................................................................................................................................................. 129-135 Applications ................................................................................................................................................ 136-138 Application Data Sheet ...................................................................................................................................... 139 Installation and Maintenance Instructions ................................................................................................. 141-158 Accessories KleenVent Reservoir Isolators – KV Series ................................................................................................ 115-118 Pulse-Tones ........................................................................................................................................................ 119 SurgeKushons – SK Series ......................................................................................................................... 121-128 Gas Inline Bottles Pulse-Tone™ Inline Pulse-Tone™ Hydraulic Shock Suppressors ..................................................................................... 87-100 Diaphragm Bladder • • • • • Series 3000 Piston Accumulators and Gas Bottles (3000 PSI & 207 Bar Metric) .............................................................. 22-39 Series 3000 Non-ASME (7” Bore) ..................................................................................................................................... 32-33 2000 PSI (12” Bore) .......................................................................................................................................................... 34-35 Series 4000 Piston Accumulators and Gas Bottles (4000 PSI & 276 Bar Metric) .............................................................. 40-49 Series 5000 Piston Accumulators and Gas Bottles (5000 PSI & 345 Bar Metric) .............................................................. 50-64 5000 Introduction ............................................................................................................................................................ 2 Certifications .......................................................................................................................................................... 3 Accumulator Selection Guide (Making the Right Choice) ............................................................................... 4-15 inPHorm™ Software ............................................................................................................................................. 16 Application Data Sheet ........................................................................................................................................ 17 Piston Accumulators – A & B Series .............................................................................................................. 19-64 4000 Catalog HY10-1630/US ntents Applications Hydraulic Accumulators Introduction Parker Accumulators are designed to optimize the performance of your hydraulic system, while adding safeguards that prolong equipment life. Reduced operating costs and savings from less downtime and maintenance are the benefits. Parker Accumulators… • Provide an auxiliary power source by holding supplemental power to be used during peak periods. This allows the use of smaller pumps, motors, and reservoirs reducing installation and operating costs. • Protect hydraulic systems and circuit components from damage due to thermal expansion and contraction in a closed system. • Make up changes in fluid volume to assure a positive pressure. • Reduce costly damage to piping systems, fittings, and gauges by absorbing hydraulic line shocks. • Supply emergency fail-safe power to complete a work safety cycle in the event of a pump or electric power failure. • Hold necessary high pressure for long periods of time while preventing oil overheating, reducing pump wear, and saving energy. • Dispense lubricants in a slow, constant rate to critical equipment wear areas. Typical Applications • Construction & Mining Equipment – emergency backup for steering, brake, and pilot circuits. • Hydrostatic Drives – shock absorption when changing directions. • Injection Molding & Die Casting – high pressure and flows in a short time period. • Plunger & Diaphragm Pumps – reduces pump pulsations. • Fork Lifts & Cherry Pickers – pressure spike dampening. • Machine Tools – maintains pressure, reduces pump size. • Transportation Vehicles – suspension systems and braking systems. • Turbine Engines – oil supply for lubrication. • Winches – maintaining line tension. 2 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA 5 bar of absolute pressure).e. Appendix 22 permits that accumulators manufactured with “forged” shells. Accumulators are categorized as unfired pressure vessels and fall under the jurisdiction of ASME Code when required by state law. Division 1. For example. manufacture and conformity assessment of pressure equipment and assemblies of pressure equipment with maximum allowable pressure greater than 0. with a volume greater than 1 liter and a product of service pressure (PS) and volume (V) which is greater than 50 bar. The program aims to ensure the free placing on the market and putting into service of relevant equipment within the European Union and the European Economic Area. Accumulators must be manufactured from materials that meet ASME specifications and require a design factor of 4:1 in the ratio of burst pressure to rated pressure. Liechtenstein. Other particular regulations must be observed in certain industries such as ship building. which have applied to join the European Union.: 1. The Directive requires that all pressure equipment and assemblies within its scope must be safe when placed on the market and put into service. Similar requirements to the PED have been adopted by many other countries. In 48 states. with openings of a specified maximum size. However. etc. The “U” symbol is an internationally recognized symbol of design and manufacturing quality. Pressure Equipment Directive (PED) The Pressure Equipment Directive is one of the series of technical harmonization directives covering subjects such as machinery. and/or ordinances which are valid in the state or country of set-up. plus Iceland. or for any pressure vessel where PS exceeds 1000 bar. unlike many other standards around the world.5 bar above atmospheric pressure (i. simple pressure vessels. regulations. The PED applies in the member states of the European Union (EU) and the European Economic Area (EEA). testing and conformity assessment of pressure equipment and assemblies of pressure equipment. This 4:1 requirement is mandatory for all accumulators with ASME Certification with the exception ofthose that comply with a specific rule within the Code called “Appendix 22”. Norway. And at present.: non-hazardous). there is no ASME national requirement for periodic inspection of accumulators after installation. manufacture. ASME Certification is required on pressure vessels used within their boundaries. The PED Conformity Assessment Modules apply to all accumulators using fluids in Group 2 (i. The Pressure Equipment Directive applies to the design. Accumulators specifically fall under the section of the code referred to as Section VIII. ASME Certification requires third party surveillance of an approved quality system and requires witness by a third party of all hydrostatic testing. local laws would dictate such inspections. Illinois USA . This section requires certification on vessels with internal diameters of 6" or greater and that certified vessels carry the “U” symbol on them as evidence that they were designed and manufactured in accordance with the Code. The EU member states are: Austria Belgium Finland France Germany Greece Ireland Italy Luxembourg Netherlands Portugal Spain Sweden United Kingdom Denmark The European Economic Area (EEA) includes the 15 EU countries listed above. in the US most states require ASME Certification on larger bore Hydraulic Accumulators Introduction accumulators and gas bottles.Catalog HY10-1630/US Page Certifications Accumulators and Gas Bottles are pressure vessels which are subject to safety laws.. ASME Certification ASME (American Society of Mechanical Engineers) is an organization that regulates the design and manufacture of pressure vessels in the United States. etc. ASME requires that each vessel be marked with the design pressure at the Minimum Design Metal Temperature (MDMT) for the vessel. Similar laws. The purpose of the PED is to harmonize national laws of Member States regarding the design. regulations. aircraft. may be Certified with a design factor of 3:1 in the ratio of burst pressure to rated pressure.liter. mining. and Switzerland. which were identified by the European Community’s program for the elimination of technical barriers to trade. gas appliances. The essential criteria of ASME Certification is a requirement of strength and material traceability. and/or ordinances apply in other countries as well. 3 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.e. three types of hydro-pneumatic accumulators are widely used – the piston type. The correct selection and application of different style accumulators is examined in the following pages. bladder type and diaphragm type. Piston accumulators offer greater efficiency and flexibility in most applications. Parker’s piston. A correctly specified accumulator can: • reduce shock effects in a system resulting from inertia or external mechanical forces • maintain system pressure by compensating for pressure loss due to leakage • provide a back-up supply of hydraulic energy to maintain a constant flow when system demand is greater than pump delivery. compact • simple. low lubricity fluids • fully serviceable Diaphragm Advantages • lightweight. Bladder Advantages • • • • • dirt tolerant universal application safety quick response works well on water. high fluid contamination and fast response times are required. Each has particular advantages and limitations which should be considered when selecting an accumulator for a specific application. bladder and diaphragm accumulators use different mechanisms to separate the gas from the fluid. without rolling. cost effective • dirt tolerant • quick response 4 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. due to their wider range of sizes. In industrial applications. pressurized by an external gas supply. They provide excellent gas/fluid separation. They use compressed gas to apply force to hydraulic fluid. Sealing remains effective even under rapid cycling at high operating pressures. Illinois USA .Catalog HY10-1630/US ntents Accumulator Selection Guide Hydraulic Accumulators Introduction Making the Right Choice Hydro-pneumatic accumulators are the most widely used type of accumulator in industrial and mobile hydraulic systems. Piston Advantages • • • • • • • extremely high flow rates high/low temperature tolerance high compression ratios withstands external forces unlimited sizes/mounting work well with gas bottles fully serviceable Parker’s hydro-pneumatic accumulators regulate the performance of a hydraulic system by providing an additional volume of system fluid. Parker’s piston accumulators feature a patented five-blade V-O-ring which maintains full contact between the piston and the bore. It is this difference – and the resulting performance characteristics – which determines their suitability for different applications. Bladder/Diaphragm accumulators are generally preferred for applications where rapid cycling. Identical in their operating principle. for optimum flexibility. Diaphragm Accumulators Parker diaphragm accumulators feature a one piece molded diaphragm which is mechanically sealed to the high strength metal shell. regulates fluid flow through the hydraulic port. normally held open by spring pressure.Catalog HY10-1630/US Page Accumulator Selection Guide Design Features and Construction Piston Accumulators Parker piston accumulators consist of a cylindrical body. to a set precharge pressure determined by the system requirements. A button molded to the bottom of the diaphragm prevents the diaphragm from being extruded out the hydraulic port. such as: nitrogen. flexible rubber bladder housed within a steel shell. Illinois USA . allowing fluid to enter or forcing it to be discharged from the accumulator body. the gas side is charged with nitrogen to a predetermined pressure. sealed by a gas cap and charging valve at the gas end. Changes in system pressure cause the piston to rise and fall. diaphragm and piston accumulators Charging Valve Shell Shell Bladder Poppet Spring Hydraulic Port BLADDER Diaphragm Charging Valve Charging Valve Gas Cap Body Piston Button Hydraulic Cap PISTON Gas Fluid Port DIAPHRAGM 5 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. A poppet valve. The open end of the bladder is attached to the precharging valve at the gas end of the shell. and by a hydraulic cap at the hydraulic end. As system pressure fluctuates. Hydraulic Accumulators Introduction Bladder Accumulators Greer bladder accumulators feature a non-pleated. Fig. or allow fluid into. The non-repairable electronbeam welded construction reduces size. the bladder/ diaphragm expands and contracts to discharge fluid from. The bladder/diaphragm is charged with a dry inert gas. Greer’s bladder accumulators are available as either top or bottom repairable units. the accumulator shell. weight. The flexible diaphragm provides excellent gas and fluid separation. As with the bladder/diaphragm accumulator. and ultimately cost. 1 Typical bladder. A lightweight piston separates the gas side of the accumulator from the hydraulic side. Stage (f) Stage (d) System pressure peaks. Stage (b) The accumulator is precharged. The accumulator has discharged its design maximum volume of fluid back into the system. Any further increase in hydraulic pressure would be prevented by a relief valve in the system. Stage (e) System pressure falls. The accumulator is filled with fluid to its design capacity. Hydraulic Accumulators Introduction Stage (c) The hydraulic system is pressurized. and neither gas nor hydraulic sides are pressurized. System pressure exceeds precharge pressure. Minimum system pressure is reached. Fig 2 Operating conditions of bladder. and fluid flows into the accumulator. Illinois USA . Precharge pressure forces fluid from the accumulator into the system. piston and diaphragm accumulators Click Here to access inPHorm online (A) (B) (C) Gas (D) (E) (F) 6 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.Catalog HY10-1630/US ntents Accumulator Selection Guide Operation Stage (a) The accumulator is empty. 100 220 397 818 1199 1982 3450 40 150 220 220 220 220 Bladder High Diaphragm Flow 11 26 600 600 600 600 42 7 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. PSI max min 2000 1500 1000 500 Recommended Precharge. The larger standard bladder designs are limited to 220 GPM. To ensure long and satisfactory service life. bladder accumulators are not generally suitable for compression ratios greater than 4:1. both system and performance criteria should be considered.41 5. 20-85 cu. Piston accumulators can also be built to custom lengths for applications in which available space is critical. in. page 11. Flow Rate Failure Modes In certain applications. the following factors should be taken into account. For a given system pressure. for example. a progressive failure mode is desirable. although this may be increased to 600 GPM using a highflow port. as these could result in excessive bladder deformation.33 Output volume Fluid type Shock suppression Mounting position Sizing information Safety ❋ 1.23 5. A high-speed machine.00 4.5-10 cu. Table 2 shows typical maximum flow rates for Parker’s accumulator styles in a range of sizes. A bladder/diaphragm accumulator would be most suitable for this application. Flow is limited by piston velocity.70 ❋ Piston 3. In this type of application a bladder style accumulator would be better suited. 2. with excessive flow causing the poppet to close prematurely. where product quality is a function of hydraulic system pressure. In this application. Also. for example. Piston accumulators are available in a choice of diameters and lengths for a given capacity. a piston accumulator would be appropriate. Table 2: Maximum Recommended Accumulator Flow Rates GPM at 3000 PSI Piston Bladder Bore Capacity 2 3 4 6 7 9 12 1 qt. PSI Bladder 1800 1350 900 ❋ Piston 1900 1400 900 400 Fluid Output GPM • • • • • • • Failure mode Flow rate Response time High frequency cycling External forces Certification Temperature effect • • • • • • Bladder 2. in. which should not exceed 10 ft/sec. whereas a gradual failure might mean that production of a large quantity of sub-standard product could occur before the failure became apparent. high seal contact temperatures and rapid decompression of nitrogen that has permeated the seal itself. Illinois USA . Conversely. 120-170 cu.5 gal. can cause blisters. Hydraulic Accumulators Introduction Table 1: Relative Outputs of a 40 litre Accumulator Compression Ratio System Pressure. a sudden failure may be preferable to a gradual failure. which may be critical in locations where space is limited. however. page 11. Table 1 compares typical fluid outputs for Parker’s 10 gallon piston and bladder accumulators operating isothermally as auxiliary power sources over a range of minimum system pressures. 1 gal. Flow rates greater than 600 GPM may be achieved by mounting several accumulators on a common manifold – see Large/Multiple Accumulators. Diaphragm Capacity . Because sudden failure is detected immediately. several methods of achieving higher output volumes than standard accumulator capacities suggest . in. and Larger Output Volume The maximum sizes available of each type of accumulator determine the limits of their suitability where large output volumes are required. and fewer sizes are available. whereas bladder and diaphragm accumulators are frequently offered in only one size per capacity. The higher precharge pressures recommended for piston accumulators result in higher outputs than from comparable bladder accumulators. flow rates for piston accumulators generally exceed those for bladder designs. There are. to avoid piston seal damage. Piston Bladder Std.79 4. cracks and pits in the seal surface.70 6. In high-speed applications.5 2 3 6 3000 3000 3000 3000 Below required minimum operating ratio of 4:1. The poppet valve controls flow rate. scrap is minimized. where continuous operation is paramount and sudden failure could be detrimental as.see Large/ Multiple Accumulators. Piston accumulators have an inherently higher output relative to their overall dimensions. in a braking or steering circuit on mobile equipment.Catalog HY10-1630/US Page Accumulator Selection Guide Accumulator Selection When selecting an accumulator for a particular application. Pressure – PSI 2000 No accumulator in circuit Piston accumulator Bladder accumulator 0 0 1000 Time – ms 2000 Fig. A Parker piston accumulator reduces the transient to 107 PSI over relief valve setting (medium trace). the difference in response is not great. tubing and a relief valve setting of 2650 PSI (Fig. a higher risk of failure exists from the same contaminants acting on the piston seal.3 Test circuit to generate and measure shock waves in a hydraulic system Fig. from a pump supplying fluid at 29. While some risk exists from contaminants trapped between the bladder and the shell. an improvement of only 20 PSI and of little practical significance. Piston seals are more easily molded in the required special compounds. Example 2 A second. This applies equally in servo applications. Substituting a 1 gal. as only a small percentage of servos require response times of 25ms or less. Installing a Greer 1 gallon piston accumulator at the valve reduces the transient to 100 PSI over relief valve setting (medium trace). while a bladder accumulator achieves a transient of 87 PSI over relief valve setting (dark trace).625 in. Illinois USA . Example 1 A test circuit (Fig. similar test using 0. Generally.Catalog HY10-1630/US ntents Accumulator Selection Guide Fluid Type Bladder/Diaphragm accumulators are more resistant to damage caused by contamination of the hydraulic fluid than piston types. Shock Suppression Shock control does not necessarily demand a bladder/diaphragm accumulator. compared to bladders. Both the piston and bladder type units require some type of preparation to resist corrosion on the wetted surfaces.3) includes a control valve situated 118 ft. and there is no piston mass to be accelerated and decelerated. Hydraulic Accumulators Introduction 4000 Pressure – PSI 2000 No accumulator in circuit Piston accumulator Bladder accumulator 0 0 1000 Time – ms 2000 Fig.25 in. Bladder accumulators are usually preferred to piston type accumulators for water service applications. Shutting the control valve (Fig.4 Shock wave test results – Example 1 Response Time In theory. The difference between accumulator types in shock suppression is again negligible. Water systems tend to carry more solid contaminants and lubrication is poor.4) produces a pressure spike of 385 PSI over relief valve setting (light trace). This is the point where the difference in response between piston and bladder accumulators becomes significant. 4000 Tubing length makes pump-toservovalve distance 36m.6 GPM. and either accumulator type for a response of 25ms or greater. bladder and diaphragm accumulators should respond more quickly to system pressure variations than piston types. There is no static friction to be overcome as with a piston seal. a bladder accumulator should be used for applications requiring less than 25ms response time. however. tubing and the relief valve is set to open at 2750 PSI. and may be less expensive. 5) results in a pressure spike of 2011 PSI over relief valve setting without an accumulator (light trace). Piston accumulators are preferred for systems using exotic fluids or where extremes of temperature are experienced as. bladder accumulator further reduces the transient to 80 PSI over relief valve setting (dark trace). and is probably insignificant in most applications. In practice. The circuit uses 1.5 Shock wave test results – Example 2 8 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. or contact us at www. to enable the accumulator to be isolated from the circuit in an emergency or for maintenance purposes. fluid can be trapped away from the hydraulic port (Fig. or the bladder may become elongated.e. In this condition. and compression ratio (i.6). Hydraulic Accumulators Introduction Forces perpendicular to an accumulator’s axis should not affect a piston model. Over an extended period. These requirements range from simple design factors to elaborate materials testing and inspection procedures carried out by an external agency. In extreme cases. Forces along the axis of the tube or shell normally have little effect on a bladder accumulator but may cause a variation in gas pressure in a piston type because of the mass of the piston. 9 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. therefore.parker.com/accumulator. with the piston cycling rapidly back and forth in a distance less than its seal width. or diaphragm ranges are available with certification to meet all major U. deceleration or centrifugal force may have a detrimental effect on its operation. maximum system pressure divided by minimum system pressure). fluid discharge could cause the poppet valve to pinch and cut the bladder.7 Perpendicular force causes the mass of the fluid to displace the bladder Acceleration Sizing Information Accurate sizing of an accumulator is critical if it is to deliver a long and reliable service life. but fluid in a bladder accumulator may be thrown to one side of the shell (Fig. but uneven wear on the top of the bladder as it rubs against the shell while floating on the fluid can reduce its service life and even cause permanent distortion. Piston models can be mounted horizontally if the fluid is kept clean but. Fig. with the hydraulic port downwards. displacing the bladder and flattening and lengthening it. and most major European standards. A bladder accumulator may also be mounted horizontally. Higher precharge pressures increase the resistance of the bladder to the effects of perpendicular forces. Illinois USA .7). Mounting Position The optimum mounting position for any accumulator is vertical. horizontal mounting can result in uneven or accelerated seal wear. cycle rate. reducing output. resulting in seal and bore wear. or accumulator size can be calculated automatically by entering application details into Parker’s inPHorm software selection program (see page 16). External Forces Any application subjecting an accumulator to acceleration. Please contact your local distributor for details. Information and worked examples are shown in the sizing section of this catalog. Most of the accumulators in Parker’s piston. Safety Hydro-pneumatic accumulators should always be used in conjunction with a safety block. a bladder/diaphragm accumulator is generally more suitable. if solid contaminants are present or expected in significant amounts.6 A horizontally-mounted bladder accumulator can trap fluid away from the hydraulic valve Accumulators are frequently required to conform to domestic or international certification. bladder. and could cause damage to a bladder accumulator. Certification Fig.Catalog HY10-1630/US Page Accumulator Selection Guide High Frequency Cycling High-frequency system pressure cycling can cause a piston accumulator to ‘dither’. The extent of the damage will depend upon fluid cleanliness.S. forcing the poppet valve to close prematurely. this condition may cause heat build-up under the seal due to lack of lubrication. For high frequency dampening applications. • Bladder installations require a special device called a transfer barrier at the gas end. The flow rate between the bladder transfer barrier and its gas bottle will be restricted by the neck of the transfer barrier tube. piston accumulators are • Diaphragm style accumulators are normally not used in Fig. Bladder designs should be sized to prevent filling to more than 75% full.8 An accumulator can be used with a remote gas bottle where space is critical Remote gas storage offers installation flexibility where the available space or position cannot accommodate an accumulator of the required size. Accumulator manifold showing three gas bottles attached to a transfer barrier type piston accumulator. subject to the following considerations. A smaller accumulator may be used in conjunction with a Parker auxiliary gas bottle. • Because of the above limitations. generally preferred to bladder types for use in gas bottle installations. 10 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . This application could therefore be satisfied with a 10 gallon accumulator and a 20 gallon gas bottle. Gas bottle installations may use either bladder or piston accumulators.8). The gas bottle is sized by the formula: For Piston Accumulators: gas bottle size = accumulator size (required output from accumulator x 1.25) For example. The gas bottle will have an equivalent port in one end and a gas charging valve at the other. conjunction with gas bottles. to prevent extrusion of the bladder into the gas bottle piping.Catalog HY10-1630/US ntents Accumulator Selection Guide Gas Bottle Installations Hydraulic Accumulators Introduction • A piston accumulator should be carefully sized to prevent the piston bottoming at the end of the cycle. to allow an unimpeded flow of gas to and from the gas bottle. an application that calls for a 30 gallon accumulator may only actually require 8 gallons of fluid output. • Any accumulator used with remote gas storage should generally have the same size port at the gas end as at the hydraulic end. which can be located elsewhere (Fig.1) For Bladder Type Accumulators: gas bottle size = accumulator size (required output from accumulator x 1. Catalog HY10-1630/US Page Accumulator Selection Guide Large/Multiple Accumulators The requirement for an accumulator with an output of more than 50 gallons cannot usually be met by a single accumulator, because larger piston designs are relatively rare and expensive, and bladder designs are not generally available in these sizes. The requirement can, however, be met using one of the multiple-component installations shown in Figs. 9 and 10. The installation in Fig. 9 consists of several gas bottles serving a single piston accumulator through a gas manifold. The accumulator portion may be sized outside of the limitations of the sizing formula on page 10, but should not allow the piston to strike the caps repeatedly while cycling. The larger gas volume available with this configuration allows a relatively greater piston movement - and hence fluid output - than with a conventionally sized single accumulator. A further advantage is that, because of the large precharge ‘reservoir’, gas pressure is relatively constant over the full discharge cycle of the accumulator. The major disadvantage of this arrangement is that a single seal failure could drain the whole gas system. The installation in Fig.10 uses several accumulators, of piston or bladder design, mounted on a hydraulic manifold. Two advantages of multiple accumulators over multiple gas bottles are that higher unit fluid flow rates are permissible, and a single leak will not drain precharge pressure from the entire system. A potential disadvantage is that, where piston accumulators are used, the piston with the least friction will move first and could occasionally bottom on the hydraulic end cap. However, in a slow or infrequently used system, this would be of little significance. Hydraulic Accumulators Introduction Fluid manifold Fig.10 (above) Multiple accumulators manifolded together offer high system flow rates Fig.9 (below) Several gas bottles can supply precharge pressure to a single accumulator Fluid Gas manifold 11 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US ntents Accumulator Selection Guide Precharging Process Correct precharging involves accurately filling the gas side of an accumulator with a dry, inert gas such as nitrogen, before admitting fluid to the hydraulic side. It is important to precharge an accumulator to the correct specified pressure. Precharge pressure determines the volume of fluid retained in the accumulator at minimum system pressure. In an energy storage application, a bladder/diaphragm accumulator is typically precharged to 90% of minimum system pressure, and a piston accumulator to 95% of minimum system pressure at the system operating temperature. The ability to correctly carry out and maintain precharging is an important factor when choosing the type of accumulator for an application. Bladder accumulators are far more susceptible to damage during precharging than piston types. Before precharging and entering in service, the inside of the shell should be lubricated with system fluid. This fluid acts as a cushion, and lubricates and protects the bladder as it expands. When precharging, the first 50 PSI of nitrogen should be introduced slowly. Failure to follow this precaution could result in immediate bladder failure: high pressure nitrogen, expanding rapidly and thus cold, could form a channel in the folded bladder, concentrating at the bottom. The chilled, brittle rubber, expanding rapidly would then inevitably rupture (Fig. 11). The bladder could also be forced under the poppet, resulting in a cut. (Fig.12). Close attention should be paid to operating temperature during precharging, as a rise in temperature will cause a corresponding increase in pressure which could then exceed the precharge limit. Little damage can occur when precharging or checking the precharge on a piston accumulator, but care should be taken to make sure the accumulator is void of all fluid to prevent getting an incorrect reading on the precharge. Hydraulic Accumulators Introduction Excessively High Precharge Excessive precharge pressure or a reduction in the minimum system pressure without a corresponding reduction in precharge pressure may cause operating problems or damage to accumulators. With excessive precharge pressure, a piston accumulator will cycle between stages (e) and (b) of Fig.2 see page 4, and the piston will travel too close to the hydraulic end cap. The piston could bottom at minimum system pressure, reducing output and eventually damaging the piston and piston seal. The piston can often be heard bottoming, warning of impending problems. An excessive precharge in a bladder accumulator can drive the bladder into the poppet assembly when cycling between stages (e) and (b). This could cause fatigue failure of the poppet spring assembly, or even a pinched and cut bladder, should it become trapped beneath the poppet as it is forced closed (Fig.12). Excessive precharge pressure is the most common cause of bladder failure. Excessively Low Precharge Excessively low precharge pressure or an increase in system pressure without a corresponding increase in precharge pressure can also cause operating problems and subsequent accumulator damage. With no precharge in a piston accumulator, the piston will be driven into the gas end cap and will often remain there. Usually, a single contact will not cause any damage, but repeated impacts will eventually damage the piston and seal. Conversely, for a bladder accumulator, too low or no precharge can have rapid and severe consequences. The bladder will be crushed into the top of the shell and can extrude into the gas stem and be punctured (Fig13). This condition is known as “pick out”. One such cycle is sufficient to destroy a bladder. Overall, piston accumulators are generally more tolerant of careless precharging. Fig.11 Starburst rupture caused by loss of bladder elasticity Fig.13 Fluid entering an un-precharged bladder accumulator has forced the bladder into the gas stem Fig.12 C-shaped cut shows that bladder has been trapped under poppet 12 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Page Accumulator Selection Guide Monitoring Piston Accumulator Precharge Several methods can be used to monitor the precharge pressure of Parker’s piston accumulators. Note that, in Figs.14b and 14c, flat pistons must be used to enable the sensors to register their positions. Hydraulic Accumulators Introduction Pressure transducer • With the hydraulic system shut down. A pressure transducer or gauge located in the gas end cap (Fig.14a) indicates the true precharge pressure after the hydraulic system has cooled and the accumulator has emptied of fluid. Fluid Fig.14a Pressure transducer measures actual precharge pressure of shut down system • With the hydraulic system operating. A piston position sensor is installed in the hydraulic end cap (Fig.14b) and connected to an electronic measuring system. With an accurate initial precharge and after sufficient system operation to ensure thermal stability, the electronics can be calibrated to provide a continuous and accurate read-out of precharge pressure. Pressure transducer Fluid Sonar absolute position sensor Fig.14b Position sensor can provide continuous indication of precharge pressure • In applications where an accumulator is coupled to a gas bottle, a Hall Effect proximity sensor can be installed in the accumulator gas end cap (Fig.14c) to detect when the piston comes within .050 inch of the cap. This system would provide a warning when precharge pressure has dropped and remedial action should be taken. Hall Effect proximity sensor Pressure transducer Fluid Fig.14c Hall Effect sensor registers proximity of piston to end cap 13 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US ntents Accumulator Selection Guide Hydraulic Accumulators Introduction • A proximity or reed switch can be used in applications where it is desirable to know when the piston is approaching the gas cap of the accumulator or to detect a low precharge. When the rod is detected by the reed or proximity switch, the switch could be set up to send out a warning signal. When used with a pressure switch, it could detect a low precharge. .) Proximity switch or Reed switch Gas valve S.S.Housing Pressure switch In some instances two reed or proximity switches could be installed on the housing. It could be required that the first switch is always made, assuring us that the precharge is not too high; if the second switch is made, it would tell us that the precharge is to low. The position of the piston can be detected a fraction of an inch to several inches before it reaches the end cap. Magnet (only if Ree d switch is used Rod Hyd. Port. Gas Bottle Fig.14d Proximity switches can sense the position of an approaching piston • In some instances, it is extremely important to know the exact location of the piston inside the accumulator. By using a linear displacement transducer (LDT), this can be accomplished. Positions as well as velocities can be determined by the use of this unit. An LDT works by sending a signal down the probe. This signal is then reflected by a magnet attached to a rod and piston assembly. The LDT records the amount of time between sending and receiving the reflected signal and then calculates the position of the piston. Multiple signals will allow the unit to calculate velocity. The result of using this unit will allow the user to know the exact cubic inches of fluid in the accumulator as well as the flow rate of the fluid. LDT Probe Magnet Hyd. Port. Fig.14e Linear Displacement Transducers (LDT) can accurately detect both piston location and velocity 14 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA installed and maintained in accordance with the guidelines contained in this catalog. failure can be predicted and repairs effected before total failure occurs. Precharge pressure – PSI Gas leaking past the piston or valve causes precharge pressure to fall (b) Number of cycles (b) Piston Accumulators Piston Accumulator failure generally occurs in one ofthe following gradual modes. precharge pressure rises and the accumulator stores and exhausts decreasing amounts of fluid. normally takes place during rapid cycling operations after considerable time in service. Fig. The reducing precharge pressure then forces progressively less fluid into the system. or from a combination of the two. Rupture cannot be predicted because the intact bladder or diaphragm is essentially impervious to gas or fluid seepage. shortened service life will result. Because the rise in precharge pressure can be measured (Fig. As the gas side slowly fills with fluid. Gas can also vent directly through a defective gas core or end cap O-ring. and if system pressures are adjusted without making corresponding adjustments to precharge pressures.15a).15). Seal deterioration occurs from excessively long service. will give many years of trouble-free use. Precharge pressure – PSI Accumulator failure is generally defined as inability to accept and exhaust a specified amount of fluid when operating over a specific system pressure range. At that point.Catalog HY10-1630/US Page Accumulator Selection Guide Failure Prevention Hydraulic Accumulators Introduction It cannot be too highly stressed that correct precharge pressure is the most important factor in prolonging accumulator life. no measurable gas or fluid leakage through the bladder or diaphragm precedes failure. repairs can again be effected before total failure occurs.15 When an accumulator bladder ruptures. The accumulator will totally fail when precharge pressure equals maximum hydraulic system pressure.15b). Conclusions A correctly specified Parker accumulator. and will contribute to the long life and high operating efficiency of the whole hydraulic system. Failure often results from an unwanted loss or gain of precharge pressure. 15 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. sometimes called dynamic transfer. from fluid contamination. If maintenance of precharge pressure and relief valve settings is neglected. Because this gradual decrease in precharge pressure can be measured (Fig. Fluid Leaks to the Gas Side This failure. The worn piston seal carries a small amount of fluid into the gas side with each stroke. Illinois USA . the accumulator will accept no further fluid. precharge pressure immediately falls to zero Number of cycles Precharge pressure – PSI As fluid leaks past an accumulator piston. Number of cycles (a) Bladder Accumulators Bladder/Diaphragm accumulator failure occurs rapidly from bladder/diaphragm rupture (Fig. The combination of clean system fluid and accurate precharging will prevent most of the common fault conditions described here. precharge pressure rises (a). Gas Leakage Precharge may be lost as gas slowly bypasses damaged piston seals. 6 Software for Accumulator Division Products Makes Sizing and Selection Easy System Highlights • Accumulator Sizing and Selection • Parametric Drawing Creation • Input Formats: Rapid Selection Systematic Design • Available Information Outputs: HPGL CAD Drawing CAD File (*. 16 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. performs the calculations. Illinois USA . “Advisor” options within the program offer additional assistance with special modifications and design considerations.6.Catalog HY10-1630/US ntents Sizing and Selection Software TM Hydraulic Accumulators Introduction Parker Version 3.dxf) Selection Summary Printout RFQ/Order Sheet Printout Systematic Design Rapid Selection Parker offers leading edge application assistance with its inPHorm™ for Accumulators. This program allows you to select the proper Parker accumulator product for your application. and eases the process of sorting through catalog drawings. You can use the program to develop a model number. Using inPHorm will increase your efficiency and minimize the engineering time required to design in accumulators. During any portion of the program. inPHorm for Accumulators guides you through the selection process. This updated version of inPHorm for Accumulators is written for use with Windows95 and later versions. charts and tables. In either case. you can view a dimensioned drawing.com/accumulator.parker. For further information or to order a CD. inPHorm for Accumulators is also available on the web at www. generate a print or DXF file and even create a quote request or order form. reference material can be accessed or printed for future use. which makes it extremely user friendly. You can also employ the “Rapid Selection” module to build a model number based on a selection of options. Version 3. call your local Parker distributor or contact us at (815) 636-4100. _______________ Seal Type/Compound:________________________ Hydraulic Port:______________________________ Gas Port: __________________________________ Operating Temperature Range:_________________ System Fluid: ______________________________ Gas Valve: _________________________________ Precharge:_________________________________ Water Service? ____________________________ Plating/Coating: ____________________________ Material Type: ______________________________ Paint: ____________________________________ Switches: _________________________________ Certification: _______________________________ Special Test? _______________________________ Special Label? _____________________________ Customer Drawing Included? _________________ Customer Part # ___________________________ Envelope Restrictions: _______________________ Application Description/Comments FORM-0117.Catalog HY10-1630/US Page Application Data Sheet Hydraulic Accumulators Introduction Contact Information CUSTOMER: ADDRESS: CONTACT: PHONE: FAX: EMAIL: Customer Requirements Quantity/Release: ___________________________ Quantity (Annual): ___________________________ Type (Piston or Bladder): _____________________ Bore Size (piston only): ______________________ Capacity: __________________________________ Working Pressure/Design Factor. Illinois USA . Rev. 1 Please fill out and fax to 815-636-4113. For assistance. 17 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. call 815-636-4100. Catalog HY10-1630/US ntents Notes Hydraulic Accumulators Introduction 18 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . Piston Accumulators • Piston Accumulators • Gas Bottles • Metric Accumulators & Bottles Features: • Heavy Duty Service with Operating Pressures to 5000 PSI • 2" thru 12" Bores with Over Fifty Standard Capacities • “Fatigue Tested” Designs. 2" thru 8" Bores • Patented V-O-ring Piston Seals • Serviceable Threaded End Construction • ASME Certification and CE Marking available • Five Standard Seal Options to Handle a Variety of Fluids and Temperatures 19 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . Many states require ASME certification. Series 4000 and Series 5000 with separate technical and ordering information. 4000 & 5000 PSI • Metric Piston Accumulators for 207. 276 and 345 Bar • A Wide Array of Options and Accessories Parker manufactures most of the components used in the construction of its piston accumulators in its own plants. absorbing hydraulic shocks. Parker offers the latest in accumulator sizing technology with its inPHorm Accumulator Sizing and Selection Software. See pages 32-33. specifying these accumulators can result in moderate savings. For your convenience. To make it easier for you to order. we have divided the piston accumulator section into Series 3000. Illinois USA . and long service life. Parker’s broad offering includes: • Piston Accumulators for 3000. 276 and 345 Bar • Metric Gas Bottles for 207. but not all. It is the function of the system designer to specify whether ASME is or is not required. Series 3000 7" and 8" Bore Now Available in Non-ASME ASME certification is a requirement of strength and material traceability (see page 4). Why Use Piston Accumulators? • • • • • • • • • • • • • improves system efficiency supplements pump flow supplies power in emergency compensates for leakage absorbs hydraulic shocks wide range of sizes extremely high flow rates high/low temperature tolerance high compression ratios can be used with remote gas bottles can be mounted in any position failure mode is gradual. Division I design requirements while utilizing industry standard materials. When ASME certification is not required. . They are suitable for storing energy under pressure. 4000 and 5000 PSI. Parker even finish skive and burnishes the majority of the tubing used to manufacture its piston accumulator shells – all processes internally controlled to Parker’s high standards of quality and consistency. The simple. predictable sensors can be fitted for performance monitoring Our Wide Range of Piston Accumulators . We now offer true non-ASME accumulators in 7” and 8" bore sizes which meet ASME Section VIII. 20 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.Catalog HY10-1630/US Overview Piston accumulators provide a means of regulating the performance of a hydraulic system. cylindrical design of piston accumulators ensures dependable performance. and dampening pump pulsation and flow fluctuations. compact. 4000 & 5000 PSI • Gas Bottles for 3000. maximum efficiency. . Piston Accumulators Introduction Series 3000 Parker Piston Accumulators… Your #1 Choice! Parker is the leading manufacturer of piston accumulators in North America. Our Piston Accumulator Series Parker offers piston accumulators rated for 3000. Metric. This design eliminates seal roll-over and ensures total separation of fluid and gas under the most severe operating conditions. The piston seal consists of a unique. SAE straight thread and SAE flange ports are fitted as standard. A wide range of port types and sizes are available. The V-O-ring seals are available in a wide variety of compounds to cover a broad range of fluids and operating temperature ranges (see Options). For 7” thru 12” bore sizes. All piston accumulators are fitted with a standard designed gas valve for ease of gas precharging. have as standard a “Schrader” style valve with a 5000 psi high pressure valve cartridge. The V-O-ring also holds full pressure throughout long idle periods between cycles. full pressure storage of hydraulic energy. 2” thru 6” bores. MS28889-2). providing dependable. the MS gas valve is standard. Spec. The threaded caps allow for easy repair and seal replacement.Catalog HY10-1630/US Design Features & Benefits Piston Accumulators Introduction Series 3000 1 Piston type accumulators are designed with compact. reducing wear and extending service life. Illinois USA . Series 3000. SAE 4bolt & special flanges. The piston seal design helps to prevent sudden failure of the accumulator. 6 7 21 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. are fitted with standard cored gas valve cartridges (ISO-4570-8V1). PTFE glide rings eliminate metal-to-metal contact between the tube and piston. The dished profile of the piston provides extra gas capacity and greater useable volume of fluid. 2 7 1 3 2 4 5 6 3 4 5 The lightweight piston design allows fast response to reduce shock in rapid cycling applications. patented fivebladed V-O-ring with back-up washers. The steel shell allows heat to dissipate effectively. The Series 4000 and Series 5000. reliable absorption of pressure peaks. BSPP . The bore is micro-finished for extended seal life. The steel gas valve protector reduces the risk of damage to the gas valve from external impact. Offered as an option is a “military” poppet-style gas valve (Mil. It ensures safe. rugged steel shell and caps. 2” thru 6” bores. NPTF. and ISO 6149-1 ports are available options. Catalog HY10-1630/US Piston Accumulators Series 3000 Series 3000 Piston Accumulators • Heavy Duty Service with 3000 PSI Operating Pressure • 2" thru 12" Bores with Over 50 Standard Capacities • Patented V-O-ring Piston Seals • Serviceable Threaded End Construction • Five Standard Seal Options to Handle a Variety of Fluids and Temperatures • ASME Certification and CE Marking Available 22 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . 1) See flange dimensions in Port Options. For specific precharge pressures. Piston travel.87 200 9.00 177.00 76. from simple modifications of standard units to complete designs. or the factory with your specific requirements. Precharge Units are shipped with a nominal nitrogen precharge as standard.Catalog HY10-1630/US Specifications Materials • Shell – high strength alloy steel • Caps – steel • Pistons – aluminum (2" thru 8").20 4. gas bottle. both SAE Straight Thread and Flange ports are available as standard. or special option that falls outside of Parker’s broad offering. 2) On standard 7". Fluids Parker’s piston accumulators are compatible with a wide variety of fluids. Note: The Parker standard gas cap will accept either style gas valve. Two types of gas valves are available on Series 3000 piston accumulators and gas bottles. Units with 2" thru 6" bores. specify “PL” port code for 2" Code 61 Flange when ordering. confined to the accumulator.9 7.6 11. All 7" thru 12" bore units are supplied with a heavy duty (military) poppet-type gas valve cartridge (MS28889-2) as standard. Flange ports are recommended at operating pressures above 2000 PSI due to pressure limitations of most #32 SAE Straight Thread fittings. are offered with a cored gas valve cartridge (ISO-4570-8V1) as standard. see tables below. Standard Ports Standard Models Metric Models BSPP Metric SAE SAE Port SAE Flange1 Port (in) Flange1 #12 – 3/4 – #12 – 1 – #20 – 1 – #24 – 1-1/2 – #32 2" Code 61 – 2" Code 61 #32 2" Code 61 – 2" Code 61 #32 2" Code 61 – 2" Code 61 – 3" Code 61 – 3" Code 61 Actual Bore Sizes & Maximum Flow Rates Pressure Ratings Nominal Bore Size (in.44 3.78 146. Recommended Flow* GPM LPM 100 380 220 834 397 1504 818 3096 1199 4538 1199 4538 1982 7502 3450 13061 Bore Size 2 3 4 6 7 8 9 12 *Note: Based on 120 in/sec maximum piston speed. Omit port code for SAE #32 Straight Thread.4 5. especially large capacity sizes.) 2 3 4 6 7 8 9 12 Actual Bore Size (in. Optional seals compatible with most industrial fluids are available with temperature ranges from -45°F to 325°F (-43°C to 162°C).02 51.) (mm) 2.8 7. In some cases. port & fitting size will become limiting factors for most applications. #5 SAE THREAD 1/2–20 UNF-2A 1/2–20 UNF-2A L07471000* L07689000* Auxiliary Gas Bottles When space does not permit the installation of the required piston accumulator. Parker representative. Standard accumulators (with nitrile seals) may be used with petroleum-based industrial oils or water-based flame resistant fluids. Available Options If your application requires a piston accumulator. must be calculated with ample margins to store the required fluid. ductile iron (9" & 12") • Gas Valve Cartridge – steel • Gas Valve Protector – steel • Piston Glide Rings – PTFE • Piston & End Seals – various polymers • Piston Seal Backups – PTFE Piston Accumulators Series 3000 Standard Ports The following ports are supplied as standard on all fluid ends and on the gas end of accumulators ordered for use with gas bottles: Notes: 1) For flange dimensions. Parker has the manufacturing and engineering expertise to design and build piston accumulators to your exacting requirements.88 301.6 Max. 8" & 9" bore accumulators. Some example of Parker’s past special designs include: • • • • Special and Stainless Steel Materials Piston Position and Velocity Sensors and Switches Water Service Non-Standard Capacities Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. a piston accumulator and gas bottle combination may be more economical. Gas Valves Parker Series 3000 piston accumulators are rated at 3000 psi and a minimum 4 to 1 design factor.03 102. For pressures over 3000 psi. see Series 4000 and Series 5000 accumulators. a smaller accumulator may be used by connecting it to an auxiliary gas bottle(s) that can be located in a nearby spot where space is available.00 228. Illinois USA 23 Piston 5000 4000 3000 . specify at the time of order. consult your local distributor. 63 16.38 17. 7-1/2 Gal.78 14. 4) When accumulators are to be used with gas bottles. 24 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . 4" & 6" bores standard with cored gas valves. 1 Gal. (cu in) 5 10 15 29 58 29 58 90 116 183 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (cu in) 6 11 16 30 59 34 63 95 121 188 68 126 241 357 588 266 382 613 959 1190 1768 2345 D-Hydraulic Port A (in) B (in) 6.38 0. 4 Gal.19 25.56 32. 3) ASME Certified and CE marked accumulators and gas bottles are available.19 10.75 6." 5) 2".63 74.25 0. Poppet type (MS28889-2) gas valve available as an option. Capacities and Dimensions Piston Accumulators Series 3000 Small Bore 3000 PSI Piston Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth Cored Gas Valve (see note) A Threaded Port Configuration F Dia.13 20 1-5/8 . 1 Gal.12 3/4 3/8 .94 22.81 52.12 1-1/2 1/2 .06 12 1-1/16 . 2) See Port Options for complete listing of optional ports.31 52. see “How to Order” information.76 8.12 3/4 – – – 3.06 11.13 12 1-1/16 . 1-1/2 Gal. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.5 Liter 1/2 Gal.56 1. 3 Liter 1 Quart 1/2 Gal.81 30. order “Accumulators for Use with Gas Bottles.75 1.Catalog HY10-1630/US Models.25 0.63 43.25 14.56 4.20 4.38 1.20 3.31 9.38 21.19 23. 1-1/2 Gal.63 96.88 1.13 24 1-7/8 . 5 Gal.24 2.34 18.75 Notes: 1) For Water Service add “W” after construction code.12 1-1/4 1/2 . 10 Gal. 2-1/2 Gal. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 5 5 6 7 10 14 18 22 25 32 29 35 48 61 87 83 97 124 165 192 260 327 2. 2-1/2 Gal. 3".1 Oil Service A2N0005D1K A2N0010D1K A2N0015D1K A2N0029D1K A2N0058D1K A3N0029D1K A3N0058D1K A3N0090D1K A3N0116D1K A3N0183D1K A4N0058D1K A4N0116D1K A4N0231D1K A4N0347D1K A4N0578D1K A6N0231D1K A6N0347D1K A6N0578D1K A6N0924D1K A6N1155D1K A6N1733D1K A6N2310D1K Fluid Volume (gal) – – – 1 Pint 1 Quart 1 Pint 1 Quart 1.19 34.63 C (in) SAE No. 10 Gal. Illinois USA .63 C (in) SAE No. 1 Gal. 4 Gal.75 20 1-5/8 . 1-1/2 Gal.25 0. A4N0058D3KTFTF A4N0116D3KTFTF A4N0231D3KTFTF A4N0347D3KTFTF A4N0578D3KTFTF A6N0231D3KTGTG A6N0347D3KTGTG A6N0578D3KTGTG A6N0924D3KTGTG A6N1155D3KTGTG A6N1733D3KTGTG A6N2310D3KTGTG Fluid Volume (gal) 1 Quart 1/2 Gal.20 4.06 24.63 16. Capacities and Dimensions Piston Accumulators Series 3000 Small Bore 3000 PSI Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia.19 51. 2-1/2 Gal. D Port Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 27 33 46 59 85 68 82 111 154 182 254 325 4.68 29.20 3.12 1-1/2 1/2 .63 74.68 51. Actual (cu in) 86 144 259 375 606 319 435 666 1012 1243 1821 2398 A (in) B (in) 11. 2-1/2 Gal.25 20. 1 Gal.75 3000 PSI Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth Gas Valve Type (see note) A Threaded Port Configuration F Dia. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 29 35 48 61 87 83 97 124 165 192 260 327 4.38 0.20 4.19 25. 1-1/2 Gal. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.38 0.12 1-1/4 1/2 .50 95.20 3.06 33.63 43. 7-1/2 Gal.50 73.50 42.38 21. 4 Gal.50 SAE No. 5 Gal.31 52.13 24 1-7/8 . 10 Gal. 1 Gal. 5 Gal.50 15. (cu in) 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (cu in) 68 126 241 357 588 266 382 613 959 1190 1768 2345 D Port (Both Ends) A (in) B (in) 10. 2-1/2 Gal. 2-1/2 Gal.25 16.75 6.38 17.Catalog HY10-1630/US Models.13 20 1-5/8 .63 96. 7-1/2 Gal. 1-1/2 Gal.75 1.81 52.75 25 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.75 6. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.19 34.88 24 1-7/8 .81 30.25 0.12 1-1/2 1/2 . 1-1/2 Gal.88 1. 1 Gal. Gas Bottle B4N0058D1K B4N0116D1K B4N0231D1K B4N0347D1K B4N0578D1K B6N0231D1K B6N0347D1K B6N0578D1K B6N0924D1K B6N1155D1K B6N1733D1K B6N2310D1K Gas Volume Nominal (gal) 1 Quart 1/2 Gal.12 1-1/4 1/2 . " 2".1 Oil Service A2N0005D2K A2N0010D2K A2N0015D2K A2N0029D2K A2N0058D2K A3N0029D2K A3N0058D2K A3N0090D2K A3N0116D2K A3N0183D2K A4N0058D2K A4N0116D2K A4N0231D2K A4N0347D2K A4N0578D2K A6N0231D2K A6N0347D2K A6N0578D2K A6N0924D2K A6N1155D2K A6N1733D2K A6N2310D2K Fluid Volume (Liters) 0.3 4. ASME Certified and CE marked accumulators and gas bottles are available.8 11.11 0.0 15.08 1.47 1.16 0.8 148.36 6.98 3. See Port Options for complete listing of port options.0 56.08 0.95 1.11 2. 26 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.9 28.1 9.5 29.25 0.Catalog HY10-1630/US Models.47 3. 4" & 6" bores standard with cored gas valves.48 0.5 60 27 3/4 – – – – 90 29 1 – M10 60 15 121 29 1 – M12 82 18 175 29 1-1/2 – M12 110 18 Notes: 1) 2) 3) 4) 5) For Water Service add “W” after construction code.9 21.69 9. Capacities and Dimensions Piston Accumulators Series 3000 Small Bore 207 Bar Metric Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth Cored Gas Valve (see note) A Threaded Port Configuration F Dia.50 0.79 5.26 10.95 1.4 D-Hydraulic Port A (mm) B (mm) 172 211 250 360 589 260 364 481 573 814 295 411 640 871 1330 441 554 778 1113 1337 1896 2454 C (mm) BSPP/G (in) SAE Flange E (mm) F (mm) G Weight (mm) (Kg) 2. order "Accumulators for Use with Gas Bottles.48 0.8 27.4 37.79 5.85 9.6 3. Poppet type (MS28889-2) gas valves available as an option.19 0.3 37.95 5.0 117.3 2.90 3.9 (cu in) 5 10 15 29 58 29 58 90 116 183 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (Liters) 0.1 2.0 15.7 19. When accumulators are to be used with gas bottles.6 13. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.7 87.56 1.56 1.47 15. see “How to Order” information.1 14.5 8.95 0.90 3.64 4.06 3. 3".98 0.03 1. Illinois USA .00 0.69 9.3 74.8 44.24 0.0 38.6 39.1 18.7 6. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.90 3.36 6. 7-1/2 Gal.47 15. 2-1/2 Gal.15 9. Gas Bottle B4N0058D2K B4N0116D2K B4N0231D2K B4N0347D2K B4N0578D2K B6N0231D2K B6N0347D2K B6N0578D2K B6N0924D2K B6N1155D2K B6N1733D2K B6N2310D2K Gas Volume Nominal (gal) 1 Quart 1/2 Gal. 10 Gal. Capacities and Dimensions Piston Accumulators Series 3000 Small Bore 207 Bar Metric Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia.Catalog HY10-1630/US Models.Port (Both Ends) A (mm) B (mm) 267 383 611 843 1302 413 525 749 1084 1308 1867 2426 BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 13 16 22 28 39 38 44 56 75 87 118 149 121 1 – M12 82 18 175 1-1/2 – M12 110 18 207 Bar Metric Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth Gas Valve Type (see note) A Threaded Port Configuration F Dia.0 38.9 28.6 20.47 3.95 5.79 5.36 4.64 4.5 29. A4N0058D2KRDRD A4N0116D2KRDRD A4N0231D2KRDRD A4N0347D2KRDRD A4N0578D2KRDRD A6N0231D2KRFRF A6N0347D2KRFRF A6N0578D2KRFRF A6N0924D2KRFRF A6N1155D2KRFRF A6N1733D2KRFRF A6N2310D2KRFRF Fluid Volume (Liters) 0.4 D .23 7.7 19. 1 Gal. 4 Gal.9 (cu in) 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (Liters) 1.06 3.1 18.26 10.9 16.4 37.4 29.79 5. Illinois USA .8 39.41 2.3 A (mm) B (mm) 295 411 640 871 1330 441 554 778 1113 1337 1896 2454 C (mm) D-Hydraulic Port BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 12 15 21 27 39 36 42 54 72 85 116 146 121 29 1 – M12 82 18 175 29 1-1/2 – M12 110 18 27 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 5 Gal. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.13 10.24 6.69 9. 1-1/2 Gal.0 15. Actual (liters) 1.95 1. 1-1/2 Gal. 2-1/2 Gal. 1 Gal.11 2.85 9.93 5.69 9. see “Port Options” for dimensions and “How to Order”.63 Thread Size (in) 2-1/2 .94 85. 32 1.62 C (in) SAE No. 5) When accumulators are to be used with gas bottles. 15 Gal.09 14.31 98.06 103.41 ±0.1 Oil Service A7K0578D3KPL A7K1155D3KPL A7K1733D3KPL A7K2310D3KPL A7K3465D3KPL A7K5775D3KPL A9K2310D3KPL A9K3465D3KPL A9K4620D3KPL A9K5775D3KPL A9K6930D3KPL A12K5775D1K A12K6930D1K A12K9240D1K A12K11550D1K Fluid Volume (gal) 2-1/2 Gal 5 Gal. 4) ASME Certified and CE marked accumulators and gas bottles are available. 25 Gal. 25 Gal. 30 Gal.25 102.13 Tube Size 2 5/8 . Notes: 1) For Water Service add “W” after construction code. Capacities and Dimensions Piston Accumulators Series 3000 Large Bore 3000 PSI Piston Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth High Pressure MS28889-2 Gas Valve A Threaded Port Configuration F Dia. 10 Gal. 20 Gal.25 48.75 0. 15 Gal. 40 Gal. 3) See Port Options for complete listing of optional ports.25 57.13 ±0.00 1.” 6) Poppet type (MS28889-2) gas valve standard.18 121.Catalog HY10-1630/US Models.25 42.88 119. 30 Gal. 28 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. The Minimum Design Metal Temperature (MDMT) for ASME certified 12” piston accumulators presented in this section is 32°F (0°C).50 The Minimum Design Metal Temperature (MDMT) for ASME certified 7” and 9” piston accumulators presented in this section is 20°F (-7°C). Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.12 or 2” Code 61 Flange (PL)2 3" SAE Flange Ports (Code 61) See Port Options for Dimensions 2 3/4 . two options are available.94 E (in) F (in) G (in) Weight (lbs) 170 226 283 340 454 682 595 758 920 1083 1246 1336 1490 1799 2108 8. 7-1/2 Gal.63 7/8-9 (6X) 9.06 11.50 76. order accumulator with optional standard 2" SAE Code 61 4-bolt flange port by specifying “PL” code when ordering or order the accumulator with a SAE #24 port or smaller.09 1. 10 Gal.63 2-1/2 . 50 Gal. (cu in) 578 1155 1733 2310 3465 5775 2310 3465 4620 5775 6930 5775 6930 9240 11550 Gas Volume (cu in) 633 1210 1788 2365 3520 5830 2400 3555 4710 5865 7020 5975 7130 9440 11750 D-Hydraulic Port A (in) B (in) 27.75 66. see “How to Order” information.02 ±0.25 72.00 1.12 or 2” Code 61 Flange (PL)2 32 1. Illinois USA .25 162. order “Accumulators for Use with Gas Bottles. 25 Gal. 2) Most SAE #32 fittings are rated for 2000 PSI.16 7. If 2000 to 3000 PSI service is required.18 5.37 67. 16 7. 20 Gal. 40 Gal.62 137.63 5/8 .94 11. 7-1/2 Gal.88 119. 5 Gal.06 1. 25 Gal. (cu in) 578 1155 1733 2310 3465 2310 3465 4620 5775 6930 5775 6930 9240 11550 Gas Volume (cu in) 633 1210 1788 2365 3520 2400 3555 4710 5865 7020 5975 7130 9440 11750 A (in) B (in) 25.75 0. 10 Gal.25 121.63 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread 3" SAE Flange Ports (Code 61) See Port Options for Dimensions 3/4 .63 55. 15 Gal. A7K0578D3KPLPL A7K1155D3KPLPL A7K1733D3KPLPL A7K2310D3KPLPL A7K3465D3KPLPL A9K2310D3KPLPL A9K3465D3KPLPL A9K4620D3KPLPL A9K5775D3KPLPL A9K6930D3KPLPL A12K5775D3KPNPN A12K6930D3KPNPN A12K9240D3KPNPN A12K11550D3KPNPN Fluid Volume (gal) 2-1/2 Gal.75 66.06 5/8 .25 72.25 102.09 1.9 (6X) 9. 10 Gal. 30 Gal.25 118.31 98.13 14. Capacities and Dimensions Piston Accumulators Series 3000 Large Bore 3000 PSI Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia.50 29 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.18 5. 15 Gal.18 5.13 ±0.06 103.00 1.75 65.63 70.02 ±0.02 ±0.00 1. 7-1/2 Gal.25 42.50 76.13 14. 10 Gal.25 101.62 C (in) D Port 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread E (in) F (in) G (in) Weight (lbs) 160 217 274 331 445 546 709 872 1035 1197 1246 1400 1709 2017 8.09 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread 3" SAE Flange Ports (Code 61) See Port Options for Dimensions 3/4 . 15 Gal. 40 Gal. Gas Bottle B7K0578D3K(PL) B7K1155D3K(PL) B7K1733D3K(PL) B7K2310D3K(PL) B7K3465D3K(PL) B9K2310D3K(PL) B9K3465D3K(PL) B9K4620D3K(PL) B9K5775D3K(PL) B9K6930D3K(PL) B12K5775D1K B12K6930D1K B12K9240D1K B12K11550D1K Gas Volume Nominal (gal) 2-1/2 Gal.50 3000 PSI Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure MS 28889-2 Gas Valve A Threaded Port Configuration F Dia.25 57.09 7/8 .16 7.41 ±0.Catalog HY10-1630/US Models. 15 Gal. 10 Gal.63 47.00 1.00 1.50 119. 25 Gal. 5 Gal.69 97.09 1. 50 Gal. 30 Gal. 20 Gal.25 48.13 ±0.41 ±0.00 D Port (Both Ends)(in) 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread E (in) F (in) G (lbs) Weight 170 226 283 340 454 595 758 920 1083 1246 1336 1490 1799 2108 8. 50 Gal. Illinois USA .63 40. 30 Gal.00 65. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No. 30 Gal.94 85.9 (6X) 9. 25 Gal.37 67.88 74.75 0.94 11.63 7/8 .63 100. 25 Gal. Actual (cu in) 677 1254 1832 2401 3556 2474 3629 4620 5775 6930 6288 7443 9783 12093 A (in) B (in) 27. 9 103 129 154 206 270 344 417 491 565 606 676 816 956 206.9 28.6 114 151 189 (cu in) 578 1155 1733 2310 3465 2310 3465 4620 5775 6930 5775 6930 9240 11550 Gas Volume (Liters) 10. Capacities and Dimensions Piston Accumulators Series 3000 Large Bore 207 Bar Metric Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth High Pressure MS28889-2 Gas Valve A Threaded Port Configuration F Dia. order accumulator with optional standard 2" SAE Code 61 4-bolt flange port by specifying “PL” code when ordering or order the accumulator with a SAE #24 port or smaller. see “Port Options” for dimensions and “How to Order”. 2) Most SAE #32 fittings are rated for 2000 PSI.7 39.4 19.8 57. 5) When accumulators are to be used with gas bottles.47 18. Illinois USA .7 113.4 37.29 41 – 2"Metric Code 61 Flange 3" Metric Code 61 Flange M20 182 30 365.” 6) Poppet type (MS28889-2) gas valve standard.2 96.7 94.3 77.8 75.8 37. 30 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. see “How to Order” information. two options are available.9 117 155 193 D-Hydraulic Port A (mm) B (mm) 692 1073 1454 1835 2597 1238 1700 2161 2622 3083 1715 1938 2512 3038 C (mm) BSPP/G (in) SAE Flange 2" Metric Code 61 Flange E (mm) F (mm) G Weight (mm) (Kg) 76.9 56. If 2000 to 3000 PSI service is required.29 41 – M20 (6X) 230 30 Notes: 1) For Water Service add “W” after construction code.Catalog HY10-1630/US Models. 4) ASME Certified and CE marked accumulators and gas bottles are available.2 115.1 97. 3) See Port Options for complete listing of optional ports. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.6 94.9 ±2.52 41 – M16 150 24 279.3 38.9 ±2.3 58.9 56.8 29.1 Oil Service A7K0578D2K A7K1155D2K A7K1733D2K A7K2310D2K A7K3465D2K A9K2310D2K A9K3465D2K A9K4620D2K A9K5775D2K A9K6930D2K A12K5775D2K A12K6930D2K A12K9240D2K A12K11550D2K Fluid Volume (Liters) 9.5 ±1. order “Accumulators for Use with Gas Bottles. 2 96. 5 Gal.9 56.6 113.8 57. 10 Gal.9 28.3 77.4 37.1 97.1 115. 30 Gal.6 103 122 160 198 A (mm) B (mm) 692 1073 1454 1835 2597 1238 1700 2161 2623 3085 1715 1938 2512 3038 C (mm) D-Hydraulic Port BSPP/G (in) SAE Flange 2" Metric Code 61 Flange E (mm) F (mm) G (mm) Weight (Kg) 73 99 125 150 202 248 322 396 469 543 565 635 775 915 206.5 78.0 39.3 58.8 37.5 30.9 ±2. 50 Gal.7 39.8 75.Catalog HY10-1630/US Models.0 117. 30 Gal. 7-1/2 Gal.5 ±1.9 ±2.5 59.29 – 2" Metric Code 61 Flange 3" Metric Code 61 Flange M20 182 30 365. 25 Gal. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.29 41 – 2" Metric Code 61 Flange 3" Metric Code 61 Flange M20 182 30 365.8 29.3 58. Bolt Circle Flange Port Configuration D Hydraulic Port C B Gas Volume Nominal (gal) 2-1/2 Gal.9 ±2.9 56.4 19. 25 Gal.47 18. 10 Gal.5 ±1.6 94.29 – M20 (6X) 230 30 207 Bar Metric Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure MS 28889-2 Gas Valve A Threaded Port Configuration Model No.6 114 151 189 (cu in) 578 1155 1733 2310 3465 2310 3465 4620 5775 6930 5775 6930 9240 11550 Gas Volume (Liters) 10.52 41 – M16 150 24 279. Actual (liters) 11.52 – M16 150 24 279. Gas Bottle B7K0578D2K B7K1155D2K B7K1733D2K B7K2310D2K B7K3465D2K B9K2310D2K B9K3465D2K B9K4620D2K B9K5775D2K B9K6930D2K B12K5775D2K B12K6930D2K B12K9240D2K B12K11550D2K F Dia.3 38.29 41 – M20 (6X) 230 30 31 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Capacities and Dimensions Piston Accumulators Series 3000 Large Bore 207 Bar Metric Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia. 15 Gal.1 20.9 ±2.4 98. Illinois USA .7 94. A7K0578D2KMLML A7K1155D2KMLML A7K1733D2KMLML A7K2310D2KMLML A7K3465D2KMLML A9K2310D2KMLML A9K3465D2KMLML A9K4620D2KMLML A9K3465D2KMLML A9K4620D2KMLML A12K5775D2KMNMN A12K6930D2KMNMN A12K9240D2KMNMN A12K11550D2KMNMN Fluid Volume (Liters) 9. 40 Gal.9 117 155 193 D-Port (Both Ends) A (mm) B (mm) 651 1032 1413 1794 2556 1194 1657 2118 2581 3044 1673 1897 2470 2997 BSPP/G (in) SAE Flange 2" Metric Code 61 Flange E (mm) F (mm) G (mm) Weight (Kg) 77 103 129 154 206 270 344 417 419 565 606 676 816 956 206.3 40. 15 Gal. 20 Gal. Catalog HY10-1630/US Models.63 Thread Size (in) 2½ . 4) ASME Certified and CE marked accumulators and gas bottles are available. two options are available. but not all. Illinois USA .28 129. 32 1.25 72.” 6) Poppet type (MS28889-2) gas valve standard. It is the function of the system designer to specify whether ASME is or is not required. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No. specifying these accumulators can result in significant savings. 2) Most SAE #32 fittings are rated for 2000 PSI. 3 Mounting Holes E Thread G Depth High Pressure MS28889-2 Gas Valve A Threaded Port Configuration F Dia.94 34.25 42.94 Tube Size 2 5/8 . order “Accumulators for Use with Gas Bottles.13 ±0.68 58. 32 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Capacities and Dimensions Piston Accumulators Series 3000 Non-ASME 3000 PSI Non-ASME Piston Accumulators for Oil and Water Service ASME certification is a requirement of strength and material traceability (see page 4).18 5.12 or 2” Code 61 Flange (PL)2 32 1.25 102. If 2000 to 3000 PSI service is required. When ASME certification is not required.06 Notes: 1) For Water Service add “W” after construction code.75 0.25 162. 3) See Port Options for complete listing of optional ports. the accumulators listed on these two pages can be used with confidence when ASME certification is not required. We now offer true non-ASME accumulators in 7” and 8” bore sizes which carry a full 4:1 design factor and utilize industry standard materials.06 9. order accumulator with optional standard 2" SAE Code 61 4-bolt flange port by specifying “PL” code when ordering or order the accumulator with a SAE #24 port or smaller. see “Port Options” for dimensions and “How to Order”. Many states require ASME certification. However.81 46.25 22.75 0.50 82. 5) When accumulators are to be used with gas bottles.06 ±0.1 Oil Service A7N0578D3KPL A7N1155D3KPL A7N1733D3KPL A7N2310D3KPL A7N3465D3KPL A7N5775D3KPL A8N0578D3KPL A8N1155D3KPL A8N1733D3KPL A8N2310D3KPL A8N3465D3KPL A8N5775D3KPL Fluid Volume (gal) 2½ 5 7½ 10 15 25 2½ 5 7½ 10 15 25 (cu in) 578 1155 1733 2310 3465 5775 578 1155 1733 2310 3465 5775 Gas Volume (cu in) 633 1210 1788 2365 3520 5830 655 1232 1810 2387 3542 5852 D-Hydraulic Port A (in) B (in) 27.25 57. Local rules and regulations should be followed.63 2½-12 or 2” Code 61 Flange (PL)2 2 5/8-18 6.68 C (in) SAE No. see “How to Order” information.94 E (in) F (in) G (in) Weight (lbs) 170 226 283 340 454 682 216 268 321 374 479 690 8. 94 33 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.18 6.63 5/8 .50 21. A7N0578D3KPLPL A7N1155D3KPLPL A7N1733D3KPLPL A7N2310D3KPLPL A7N3465D3KPLPL A7N5775D3KPLPL A8N0578D3KPLPL A8N1155D3KPLPL A8N1733D3KPLPL A8N2310D3KPLPL A8N3465D3KPLPL A8N5775D3KPLPL Fluid Volume (gal) 2½ 5 7½ 10 15 25 2½ 5 7½ 10 15 25 (cu in) 578 1155 1733 2310 3465 5775 578 1155 1733 2310 3465 5775 Gas Volume (cu in) 633 1210 1788 2365 3520 5830 650 1228 1806 2381 3537 5847 A (in) B (in) 25.25 162.94 9.25 57.13 ±0.06 5/8 .94 9.18 6.81 46.63 70. Illinois USA .94 34.63 100.06 1.06 56.63 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread 5/8 .06 ±0.25 42.25 129.25 102.06 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread 5/8 . Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.75 0. Capacities and Dimensions Piston Accumulators Series 3000 Non-ASME 3000 PSI Non-ASME Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia.63 55.88 80. Gas Bottle B7N0578D3K(PL) B7N1155D3K(PL) B7N1733D3K(PL) B7N2310D3K(PL) B7N3465D3K(PL) B7N5775D3K(PL) B8N0578D3K(PL) B8N1155D3K(PL) B8N1733D3K(PL) B8N2310D3K(PL) B8N3465D3K(PL) B8N5775D3K(PL) Gas Volume Nominal (gal) 2½ 5 7½ 10 15 25 2½ 5 7½ 10 15 25 Actual (cu in) 787 1309 1942 2464 3619 5929 772 1350 1928 2503 3659 5969 A (in) B (in) 27.18 5.18 5.75 0.13 ±0.63 40.75 0.50 82.06 D Port (Both Ends)(in) 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread E (in) F (in) G (lbs) Weight 170 226 283 340 454 682 216 268 321 374 479 690 8.31 33.25 72.63 128.06 ±0.13 22.68 C (in) D Port 2" Code 61 Flange (PL)2 or #32 SAE Straight Thread E (in) F (in) G (in) Weight (lbs) 160 217 274 331 445 673 205 257 310 363 468 679 8.Catalog HY10-1630/US Models.94 3000 PSI Non-ASME Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure MS 28889-2 Gas Valve A Threaded Port Configuration F Dia.63 160.18 45.68 58.75 0.06 1. 62 97. see “How to Order” information. We offer a 2000 PSI accumulator in 12” bore size and a variety of capacities for industries where lower pressure ratings can be used. 2) Most SAE #32 fittings are rated for 2000 PSI. order “Accumulators for Use with Gas Bottles.19 76. 5) When accumulators are to be used with gas bottles. If 2000 to 3000 PSI service is required. 3) See Port Options for complete listing of optional ports. 4) ASME Certified and CE marked accumulators and gas bottles are available. order accumulator with optional standard 2" SAE Code 61 4-bolt flange port by specifying “PL” code when ordering or order the accumulator with a SAE #24 port or smaller.75 66.” 6) Poppet type (MS28889-2) gas valve standard. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 1048 1193 1338 1628 1918 14.00 1.1 Oil Service A12K4620K1K A12K5775K1K A12K6930K1K A12K9240K1K A12K11550K1K Fluid Volume (gal) 20 25 30 40 50 (cu in) 4620 5775 6930 9240 11550 Gas Volume (cu in) 4820 5975 7130 9440 11750 D-Hydraulic Port A (in) B (in) 55. Capacities and Dimensions Piston Accumulators Series 2000 PSI 3000 2000 PSI Piston Accumulators for Oil and Water Service The aluminum die casting industry has been the primary user of our 2000 PSI accumulators. two options are available.50 Notes: 1) For Water Service add “W” after construction code.09 1. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.02 ±0.Catalog HY10-1630/US Models.37 C (in) SAE No. 34 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. see “Port Options” for dimensions and “How to Order”.50 118.62 3" SAE Flange Ports (Code 61) See Port Options for Dimensions 7/8-9 (6X) 9. Illinois USA . 3 Mounting Holes E Thread G Depth High Pressure MS28889-2 Gas Valve A Threaded Port Configuration F Dia. 88 116.50 118. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.02 ±0.13 64.9 (6X) 9.Catalog HY10-1630/US Models. Capacities and Dimensions Piston Accumulators Series 2000 PSI 3000 2000 PSI Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth A F Dia.09 7/8 .75 D Port (Both Ends)(in) 3" SAE Flange Ports (Code 61) See Port Options for Dimensions E (in) F (in) G (lbs) Weight 1048 1193 1338 1628 1918 14.50 2000 PSI Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure MS 28889-2 Gas Valve A Threaded Port Configuration F Dia.00 1.02 ±0.50 35 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.37 C (in) D Port 3" SAE Flange Ports (Code 61) See Port Options for Dimensions E (in) F (in) G (in) Weight (lbs) 957 1167 1312 1606 1896 14.09 1. Gas Bottle B12K4620K1K B12K5775K1K B12K6930K1K B12K9240K1K B12K11550K1K Gas Volume Nominal (gal) 20 25 30 40 50 Actual (cu in) 4620 6288 7443 9783 12093 A (in) B (in) 55.75 66.9 (6X) 9.00 1.00 95.62 97.56 75. A12K4620K3KPNPN A12K5775K3KPNPN A12K6930K3KPNPN A12K9240K3KPNPN A12K11550K3KPNPN Fluid Volume (gal) 20 25 30 40 50 (cu in) 4620 5775 6930 9240 11550 Gas Volume (cu in) 4820 5975 7130 9440 11750 A (in) B (in) 54.19 76. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.62 7/8 . Illinois USA . 48 #5 SAE Straight Port Th’d 1) Assembly includes housing and rupture disk. Gas Valve Option (M) The military style (MS) gas valve is available on 2" thru 6" bores as an option (M). For the Minimum Design Metal Temperature (MDMT) of ASME certified accumulators. Safety fuses can be installed on all piston accumulators by using the “Fuse Adapter” as shown to the right. order P/N 0864712000.e. ** The temperatures listed indicate the operating temperature range of the seals. Fuse Adapter 36 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 4" bore units and above can be equipped with a fuse port machined in the gas cap by specifying the “Safety Fuse Option” (F) at the time of order in the model code. Modifications include electroless nickel plating all surfaces and metal parts.77 1. Illinois USA . Safety fuses are available on most sizes of piston and bladder accumulators and gas bottles.55 #8 SAE 3/4-16 UNF-2A 1. refer to page 28.44 0.95 #5 SAE Straight Port Th’d 3. L07689000* 1/2–20 UNF-2A Safety Fuse Options (F) Safety Fuses are used as a safety device on accumulators and gas bottles to prevent over-pressurization of gas due to external heat or hydraulic pressure (set at 140% of maximum system pressure to avoid rupture disk fatigue and premature failure). maintains sealing effectiveness at a wide range of temperatures Compatible with most mineral oil-based fluids and maintains sealing effectiveness at low temperatures Q *Note: Consult local distributor or factory for fluid compatibility information. Consult factory for details. The rupture disks are calibrated to rupture at a predetermined pressure. for an assembly with a 2000 PSI setting. Seals Seal Code K E D H Polymer BunaNitrile Fluorocarbon Elastomer Ethylene Propylene Hydrogenated Nitrile Low Temp.70 0. Nitrile Operating Temperature Range -20°F to 165°F -29°C to 74°C -10°F to 250°F -23°C to 121°C -40°F to 250°F -40°C to 121°C -25°F to 320°F -32°C to 160°C -45°F to 160°F -43°C to 85°C **Recommended Maximum Temperature with Reduced Life 200°F 93°C 400°F 204°C 300°F 149°C 350°F 177°C 200°F 93°C General Application and Compatibility* Parker's Standard Compound – Compatible with most mineral oil-based fluids Compatible with most mineral oil-based fluids at higher temperatures and some exotic fluids Compatible with most phosphate ester fluids and some synthetic fluids Compatible with most oil-based and biodegradable fluids. Specify when ordering.25 #8 SAE Straight Port Th’d 0.Catalog HY10-1630/US Options Water Service Option (W) Piston Accumulators Series 3000 Piston accumulators are available for use with water as the fluid media.” The safety fuse assembly and/or fuse adapter must be ordered separately. xxxx = pressure setting in 100 psi increments. not the accumulator. Description Safety Fuse Assembly1 Replacement Rupture Disks Fuse Adapter Part Number 086471xxxx 756003xxxx 1468970002 Fuse 1.. i. see “How to Order. 188 3 1. SAE 4-Bolt Flange Port Dimensions Standard Pressure – 3000 PSI (207 Bar) Flange Size in 1½" 2" 2½" 3" SAE Code 61 Flange Dimensions (in.1 M16 61.9 M12 50.13 1.188 5/8 -11 2.750 1½ 1.7 69. 2) BSPT and Metric ports available.438 4.688 3.000 3.8 51 26.4 76 30. B A (4 places) x G Min.188 C F Note: Some flanges using this bolt pattern are not rated for 3000 PSI.) A B C F G 1/2 .062 1/2 . Illinois USA .9 M12 42. Port Adapters A wide variety of port adapters are offered for those that wish to convert Parker’s standard SAE port offerings to NPTF or smaller SAE port sizes.Catalog HY10-1630/US Port Options Optional Ports Piston Accumulators Series 3000 The following ports are available as options on all Series 3000 piston accumulators SAE Straight Thd. Size Code Bore 3/8" RA 2" 1/2" RB 2" 3/4" RC 2" 1" RD 3" 1¼" RE 3" 1½" RF 4" 2" RG 4" — — — ISO 6149-1 Port Port Min.062 1/2 .8 88. 37 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.9 64 30. Size Code Bore M14 YA 2" M18 YB 2" M22 YC 2" M27 YD 2" M33 YE 3" M42 YF 3" — — — — — — Note: 1) 3000 PSI SAE Code 61 (ISO 6162) Flange dimensions are shown below.9 77. Depth Flange Size mm 38 51 64 76 Metric ISO6162 Flange Dimensions (mm) A B C F G M12 35. see Accumulator Accessories. Bore 2" 2" 2" 3" 3" 4" 4" — BSPP Port Port Min. Inch Metric Bore PT MT 3" PU MU 3" PV MV 3" PW MW 3" PJ MJ 4" PL ML 6" PM MM 6" PN MN 7" NPT Port Port Size Code 3/8" UT 1/2" UU 3/4" UV 1" UW 1¼" UX 1½" UY 2" UZ — — Min.062 2 1. For a complete listing.13 2. Size Code Bore #5 TA 2" #6 TB 2" #8 TC 2" #10 TI 2" #12 TD 2" #16 TE 3" #20 TF 3" #24 TG 4" Port Size 1/2" 3/4" 1" 1¼" 1½" 2" 2½" 3" Code 61 Flange Port Code Min.13 1. Port Port Min.1 Note: Some flanges using this bolt pattern are not rated for 3000 PSI. consult factory.9 106.406 2.500 2½ 1.9 38 26. See “Accumulator Accessories. or special option that falls outside of Parker’s broad offering.) Fluorocarbon EPR Hydrogenated Nitrile Low Temp Nitrile *CF = Consult Factory 2" RK0200K000 RK0200E000 RK0200D000 RK0200H000 RK0200Q000 3" RK0300K000 RK0300E000 RK0300D000 RK0300H000 RK0300Q000 4" RK0400K000 RK0400E000 RK0400D000 RK0400H000 RK0400Q000 Bore Size 6" RK0600K000 RK0600E000 RK0600D000 RK0600H000 RK0600Q000 7” RK0700K000 RK0700E000 RK0700D000 RK0700H000 RK0700Q000 9” RK0900K000 RK0900E000 RK0900D000 CF* RK0900Q000 12” RK1200K000 RK1200E000 CF* CF* CF* Mounting. When ordering seal kits. gas bottle. Parker has the manufacturing and engineering expertise to design and build piston accumulators to your exacting requirements. 7A. consult your local distributor. 7. 6. please supply the complete model and serial numbers from the name plate and specify fluid type and operating temperature. from simple modifications of standard units to complete designs. Piston Accumulators Series 3000 Parts List 1 2 3 4 5 5A 6 7 7A 8 8A 9 Body Hydraulic Cap Gas Cap Piston V-O-ring Piston Seal V-O-ring Backups PTFE Glide Rings O-ring O-ring Backup Gas Valve Gas Valve O-ring Gas Valve Guard 9A Screw 3000 PSI Seal Kit Numbers (Includes items 5.” Special Options If your application requires a piston accumulator. or the factory with your specific requirements. Some example of Parker’s past special designs include: • • • • • • • Special and Stainless Steel Materials Piston Position and Velocity Sensors and Switches Special Seals Non-Standard Capacities Tie Rod Construction Special Certifications Spring & Weight Loaded Consult the experts at Parker with your next piston accumulator requirement! 38 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . 5A. 8A) Material Buna-Nitrile (Std. Parker representative. charging and gauging accessories.Catalog HY10-1630/US Parts and Accessories Seal Kits Seal Kits are available for all piston accumulator models. Charging & Gauging Accessories Parker offers a wide variety of mounting. in. in.90 liters) 183 cu. in. (94.69 liters) 2½ gal. (56. (37. Illinois USA . (189 liters) Hydraulic and Gas Port Modifications Designated by 2 Digits 1st Digit Style Std. (0. Port NPT 3/4” Gas Port Design Pressure D K X L H 3000 PSI (All Bore Sizes) 2000 PSI (12" Bore only) Other For CE Marked Only 250 Bar (All Bore Sizes) 350 Bar (See page 63) Standard Ports Available (See Port Modifications Table if Using Other Than Standard Ports Shown Below) Bore Size 2” 3” 4” 6” 7” 8” 9” 12” Standard Port Sizes SAE #12 SAE #12 SAE #20 SAE #24 SAE #32 SAE #32 SAE #32 3” SAE Flange Code 61 Metric Port Sizes 3/4 3/4 1 1 ISO 6162 ISO 6162 ISO 6162 ISO 6162 Seal Compound (See Catalog for Temperature Settings) K E D H Q S Buna-Nitrile (Std) Fluoroelastomer EPR Hydrogenated Nitrile Low Temp. See Port Table) Special Design 39 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.11 F 1 1/2 .16 liters) 29 cu. (18.95 liters) 90 cu. 6". (0.47 liters) 5 gal. Order fuse assembly separately.S. (114 liters) 40 gal.M. (15.47 liters) 4 gal. mat’l standard on 7” & up Same as K with A.9 liters) 15 gal. in. CE marked (1 liter and above) or SEP marked (under 1 liter) P Flange (Code 61) M Metric Flange per ISO 6162 6” K 7” L U NPTF (Not Recommended) 8” E 9” R BSPP Parallel B BSPT Taper Port G Metric Y ISO 6149-1 J 1 1/2” L 2” M 2 1/2” N 3” T 1/2” U 3/4” V 1” W 1 1/4” T 3/8” U 1/2” V 3/4” W 1” X 1 1/4” Y 1 1/2” Z 2” BSPP/BSPT A 3/8 . in. (56. and place them in the sequence indicated by the example at the top of the chart. (5. Special (to be specified) * Safety fuse assembly not included.9 liters) 15 gal. Bore 4” 6” 6” 7” 3” 3” 3” 3” 2” 2” 2” 2” 2” 4” 4” Metric/ISO 6149-1 A M14 x 1.95 liters) 29 cu.9 liters) 7½ gal. Water Service Fuse* and MS28889-2 Fuse* and MS28889-2.00 liters) 58 cu.20) SAE #6 (9/16 . (28.90 liters) 1 gal. (56.4 liters) 10 gal.79 liters) 1½ gal. 2nd Digit Blank A B C D E F G H I Description Std. (3. (9.8 liters) 20 gal. (1. 2” 2” 2” 2” 3” 3” 4” 7” 2” Min.14) Type of Construction N Threaded both ends non-ASME mat’l standard on 2".12) SAE #20 (1 5/8 .9 liters) 2½ gal.12) SAE #24 (1 7/8 . (9. Bore Size Nominal Bore Size 2 3 4 6 7 8 9 12 2 inches 3 inches 4 inches 6 inches 7 inches 8 inches 9 inches 12 inches Blank 3” T SAE Straight Thread Ports 4” SAE #5 (1/2 .11 E 1 1/4 . in. (0.48 liters) 58 cu.12) SAE #10 (7/8 .S.5 B M18 x 1. (18.6 liters) 30 gal.Catalog HY10-1630/US Ordering Information How to Order Piston Accumulators Piston Accumulators Series 3000 Piston accumulators and gas bottles can be specified by using the symbols in the chart below to develop a model number.11 G 2 .11 Options Blank W F G M L P R Standard Gas Cap Water Service SAE Fuse Port * SAE Fuse Port *. in.14 C 3/4 .18) SAE #8 (3/4 .79 liters) 1½ gal.14 D 1 .69 liters) 2½ gal.1 liters) 5 gal. (151 liters) 50 gal. in. (94.6 liters) 25 gal. (28.5 D M27 x 2 E M33 x 2 F M42 x 2 G M48 x 2 Min. Nominal Bore Type of Size Construction Options Design Pressure Design Number Seal Compound Hyd.8 liters) 25 gal. (3. (0.6 liters) 10 gal. (0. (94. approval stamp 7” & up. 4".12) SAE #16 (1 5/16 . (75. (37.16) SAE #12 (1 1/16 .48 liters) 58 cu.M.E.6 liters) 30 gal. (9. or Gas.47 liters) 5 gal.5 C M22 x 1. (94.9 liters) 15 gal.12) SAE #32 (2 1/2 . Available as special on smaller sizes Threaded both ends. (113. (5.19 B 1/2 .4 liters) 10 gal. in. (0.9 liters) 7½ gal. (0.8 liters) 25 gal. (1. (1. in.E. 7" & 8" (3000 PSI fatigue design tested) Threaded both ends A. (37. Water Service MS28889-2 Gas Valve MS28889-2 Gas Valve. SAE #8 Hyd. Port Modification Gas Port Modification Series Capacity A 7 K – 2310 D 1 K – – – – Series A B Accumulator Gas Bottle 0005 0010 0029 0058 0029 0058 0090 0116 0183 0058 0116 0231 0347 0578 0231 0347 0578 0924 1155 1733 2310 0578 1155 1733 2310 3465 5775 0578 1155 1733 2310 3465 5755 2310 3465 4620 5775 6930 5775 6930 9240 11550 Bore Size/Capacity 2” 5 cu.4 liters) 10 gal. Port K T C U V Consult factory for other available sizes. (28. in.08 liters) 10 cu. (9.9 liters) 7½ gal.7 liters) 25 gal.95 liters) 116 cu.6 liters) 2½ gal. (3.47 liters) 1 gal. (37. Port (BSPP Standard) Specify Optional Ports Optional Port (Hyd. Design Number 1 2 3 *** Standard Metric Mounting Holes & Hyd. Water Service 12” Example of Optional Port Accumulator A 4 N 0231 D 3 Non-std. (18.47 liters) 116 cu. Select only those symbols that represent the features desired. Series 4000 Piston Accumulators • Heavy Duty Service with 4000 PSI Operating Pressure • 2" thru 6" Bores with Over 20 Standard Capacities • Patented V-O-ring Piston Seals • Serviceable Threaded End Construction • Five Standard Seal Options to Handle a Variety of Fluids & Temperatures 40 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.Catalog HY10-1630/US Page Piston Accumulators Series 4000 Series 4000 Accumulators Provide the Compatibility and Performance Specific for Your Mobile Application. Illinois USA . Recommended Flow* GPM LPM 100 380 220 834 397 1504 818 3096 #5 SAE THREAD 1/2–20 UNF-2A Available Options If your application requires a piston accumulator. or the factory with your specific requirements. Precharge Units are shipped with a nominal nitrogen precharge as standard. Parker has the manufacturing and engineering expertise to design and build piston accumulators to your exacting requirements.) (mm) 2. Optional seals compatible with most industrial fluids are available with temperature ranges from -45°F to 325°F (-43°C to 162°C).) 2 3 4 6 Actual Bore Size (in.03 102.20 4.00 76. Standard Ports The following ports are supplied as standard on all fluid ends and on the gas end of accumulators ordered for use with gas bottles: Standard Ports Bore Size 2 3 4 6 Standard Models SAE Port #12 #12 #16 #16 Metric Models BSPP Port (in) 3/4 3/4 1 1 41 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. especially large capacity sizes. consult your local distributor. Standard Gas Valve with High Pressure Core Actual Bore Sizes & Maximum Flow Rates Nominal Bore Size (in. Fluids Parker’s piston accumulators are compatible with a wide variety of fluids. a smaller accumulator may be used by connecting it to an auxiliary gas bottle(s) that can be located in a nearby spot where space is available.4 5. or special option that falls outside of Parker’s broad offering. Auxiliary Gas Bottles When space does not permit the installation of the required piston accumulator. port & fitting size will become limiting factors for most applications. Pressure Ratings Parker 4000 psi piston accumulators are all rated at minimum 4 to 1 design factors. must be calculated with ample margins to store the required fluid.03 51.44 3. Illinois USA . confined to the accumulator. For specific precharge pressures. In some cases. from simple modifications of standard units to complete designs. Standard accumulators (with nitrile seals) may be used with petroleum-based industrial oils or water-based flame resistant fluids. Parker representative. Some example of Parker’s past special designs include: • • • • • • • • Special and Stainless Steel Materials Piston Position and Velocity Sensors and Switches Special Seals Non-Standard Capacities Water Service Ports Fixed Gauge Mounts Fuse Plug Assemblies *Note: Based on 120 in/sec maximum piston speed. specify at the time of order. gas bottle.9 Max. Piston travel.Catalog HY10-1630/US Page Specifications Materials • • • • • • • • Shell – high strength steel Caps – steel Pistons – aluminum Gas Valve Cartridge – stainless steel Gas Valve Protector – steel Piston Glide Rings – PTFE Piston & End Seals – various polymers Piston Seal Backups – PTFE Piston Accumulators Series 4000 Gas Valve Series 4000 accumulators and auxiliary gas bottles are equipped with a high pressure cored gas valve cartridge as standard.78 146. a piston accumulator and gas bottle combination may be more economical. 7-1/2 Gal. 1-1/2 Gal.75 52. see “How to Order”.5 11. (cu in) 5 10 15 29 58 29 58 90 116 183 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (cu in) 6.5 16. 4 Gal.06 16.25 0. Capacities & Dimensions 4000 PSI Piston Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth Piston Accumulators Series 4000 High Pressure Cored Gas Valve A Threaded Port Configuration F Dia.12 1 1/2 .20 3. 3) When accumulators are to be used with Gas Bottles. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 6 6 7 9 14 17 25 33 39 56 37 46 63 81 117 110 126 158 207 239 320 401 2.13 16 1-5/16 .06 1.38 0.34 18.76 8.75 7.18 23.00 1. order “Accumulators for Use with Gas Bottles.62 25.62 32.19 23. 5 Gal. 1 Gal.56 5.62 34.5 59.06 12 1-1/16 .5 34 63 95 121 188 68 126 241 357 588 266 382 613 959 1190 1768 2345 D-Hydraulic Port A (in) B (in) 6. 2-1/2 Gal. 10 Gal.5 30.” 42 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.62 54.12 1 1/2 .25 14.50 1.12 3/4 3/8 .31 9.43 98. Illinois USA . Oil Service A2N0005E1K A2N0010E1K A2N0015E1K A2N0029E1K A2N0058E1K A3N0029E1K A3N0058E1K A3N0090E1K A3N0116E1K A3N0183E1K A4N0058E1K A4N0116E1K A4N0231E1K A4N0347E1K A4N0578E1K A6N0231E1K A6N0347E1K A6N0578E1K A6N0924E1K A6N1155E1K A6N1733E1K A6N2310E1K Fluid Volume (gal) – – – 1 Pint 1 Quart 1 Pint 1 Quart 1.19 10.81 19. 2-1/2 Gal.5 Liter 1/2 Gal. 1 Gal.43 76.43 C (in) SAE No.75 1.43 45.20 4.13 16 1-5/16 .56 32.24 2. 2) See Port Options for complete listing of optional ports. 3 Liter 1 Quart 1/2 Gal. Bolt Circle Flanged Port Configuration D Hydraulic Port C B Model No.13 12 1-1/16 .Catalog HY10-1630/US Page Models. 1-1/2 Gal.78 14.25 0.06 12.75 Notes: 1) For Water Service add “W” after construction code.12 3/4 — — — 3.94 22. 38 0. 1-1/2 Gal. Illinois USA .20 3. 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (cu in) 68 126 241 357 588 266 382 613 959 1190 1768 2345 A (in) B (in) 11. D Port A (in) B (in) 12. 1 Gal. 2-1/2 Gal.81 52.62 34.75 43 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.31 52.43 Actual (cu in) 86 144 259 375 606 319 435 666 1012 1243 1821 2398 C (in) SAE No.38 21.63 74.43 45.43 98.63 D Port (Both Ends) SAE Thread Tube No. 10 Gal. 2-1/2 Gal. 5 Gal.12 1 1/2 .63 43.75 4000 PSI Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure Cored Gas Valve A Threaded Port Configuration F Dia. 1 Gal.63 16. 2-1/2 Gal.75 7. 1-1/2 Gal.25 0.63 96. 1 Gal. 4 Gal. 1 Gal. 4 Gal. 5 Gal.18 23. 1-1/2 Gal.62 32.81 19. 7-1/2 Gal.06 16. Gas Bottle B4N0058E1K B4N0116E1K B4N0231E1K B4N0347E1K B4N0578E1K B6N0231E1K B6N0347E1K B6N0578E1K B6N0942E1K B6N1155E1K B6N1733E1K B6N2310E1K Gas Volume Nominal (gal) 1 Quart 1/2 Gal.13 16 1-5/16 . A4N0058E3KTETE A4N0116E3KTETE A4N0231E3KTETE A4N0347E3KTETE A4N0578E3KTETE A6N0231E3KTETE A6N0347E3KTETE A6N0578E3KTETE A6N0924E3KTETE A6N1155E3KTETE A6N1733E3KTETE A6N2310E3KTETE Fluid Volume (gal) (cu in) 1 Quart 1/2 Gal. Capacities & Dimensions Piston Accumulators Series 4000 4000 PSI Piston Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia. 10 Gal.75 7.75 52. 7-1/2 Gal.12 1 1/2 . Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 35 44 62 80 115 105 121 153 202 234 315 396 5.00 16 1-5/16 .20 4.43 76. Size (in) Size E (in) F (in) G (in) Weight (lbs) 37 46 63 81 117 110 126 158 207 239 320 401 5.06 1.19 25.25 0.12 1 1/2 .06 16 1-5/16 .62 25.Catalog HY10-1630/US Page Models.81 30.38 17.00 1.20 4.62 54.20 3.38 0. 2-1/2 Gal. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.19 34. 1-1/2 Gal.13 16 1-5/16 . Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.12 1 1/2 . 2) See Port Options for complete listing of optional ports.” 44 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.70 19.9 93.50 0.90 3.95 1.90 28.85 9.8 17.95 0.Catalog HY10-1630/US Page Models.2 71.0 49.08 0.98 0.69 9.7 25.79 5.26 10.36 6.90 3.98 3.48 0.25 0.47 15.00 38.8 53.95 5.40 37. order “Accumulators for Use with Gas Bottles.19 0.8 11.48 0.11 2. see “How to Order” . Illinois USA . 3) When accumulators are to be used with Gas Bottles.50 29.1 7.79 5.06 3.16 0.1 14.8 57.90 (cu in) 5 10 15 29 58 29 58 90 116 183 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (Liters) 0.11 0.6 20.64 4.6 28.24 0. Capacities & Dimensions Piston Accumulators Series 4000 276 Bar Metric Piston Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth High Pressure Cored Gas Valve A Threaded Port Configuration F Dia.40 D-Hydraulic Port A (mm) B (mm) 172 211 248 360 589 260 364 481 573 814 306 422 651 883 1341 487 600 824 1159 1383 1941 2500 C (mm) BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 2. Oil Service A2N0005E2K A2N0010E2K A2N0015E2K A2N0029E2K A2N0058E2K A3N0029E2K A3N0058E2K A3N0090E2K A3N0116E2K A3N0183E2K A4N0058E2K A4N0116E2K A4N0231E2K A4N0347E2K A4N0578E2K A6N0231E2K A6N0347E2K A6N0578E2K A6N0924E2K A6N1155E2K A6N1733E2K A6N2310E2K Fluid Volume (Liters) 0.56 1.69 9.03 1.47 1.08 1.4 2.00 0.95 1.47 3.00 15.1 4.7 36.10 18.9 109 145 182 64 27 3/4 – – – – 96 29 3/4 – M10 60 15 127 29 1 – M12 82 18 180 29 1 – M12 110 18 Notes: 1) For Water Service add “W” after construction code.56 1.8 3. Bolt Circle Flanged Port Configuration D Hydraulic Port C B Model No.1 6.4 16. 00 38.90 (cu in) 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (Liters) 1.70 19. Illinois USA .6 28.79 5. Capacities.79 5.6 106 143 180 121 29 1 – M12 82 18 175 29 1 – M12 110 18 45 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.9 36.41 2.69 9.2 47.40 37.93 5.5 54.Port (Both Ends) A (mm) B (mm) 267 383 611 843 1302 413 525 749 1084 1308 1867 2426 BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 16.00 15.6 91.6 20.9 109 145 182 121 1 – M12 82 18 175 1 – M12 110 18 276 Bar Metric Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure Cored Gas Valve A Threaded Port Configuration F Dia.95 1.80 39.47 15.30 A (mm) B (mm) 267 383 611 843 1302 413 525 749 1084 1308 1867 2426 C (mm) D-Hydraulic Port BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 15.15 9.47 15.85 9.69 9.24 6.Catalog HY10-1630/US Page Models.47 3.8 53.40 D .69 9.69 9.1 52.0 49.90 Actual (liters) 1.9 69.8 19.36 6.60 20.79 5.47 3.10 18.7 36.9 27.40 29.10 18.9 93.90 3.95 5.95 1.36 4. A4N0058E2KRDRD A4N0116E2KRDRD A4N0231E2KRDRD A4N0347E2KRDRD A4N0578E2KRDRD A6N0231E2KRDRD A6N0347E2KRDRD A6N0578E2KRDRD A6N0924E2KRDRD A6N1155E2KRDRD A6N1733E2KRDRD A6N2310E2KRDRD Fluid Volume (Liters) 0.26 10.90 28.50 29.8 57. Dimensions Piston Accumulators Series 4000 276 Bar Metric Piston Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia.2 71. Gas Bottle B4N0058E2K B4N0116E2K B4N0231E2K B4N0347E2K B4N0578E2K B6N0231E2K B6N0347E2K B6N0578E2K B6N0924E2K B6N1155E2K B6N1733E2K B6N2310E2K Gas Volume Nominal (liters) 0. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.06 3.23 7.79 5.13 10.11 2.90 3.40 37.64 4.90 28.90 16. 812 2 1.312 4. Metric pattern supplied on 276 Bar Metric units unless otherwise specified. Bore 2" 2" 2" 3" 3" 4" 4” Port Size M14 M18 M22 M27 M33 M42 — Notes: 1) 1" thru 2" flanges are to standard SAE Code 62 dimensions. Military Style (MS) Gas Valve 1/2–20 UNF-2A L07689000* 46 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Port Port Min.8 50 38.5 96.9 2. consult factory.Catalog HY10-1630/US Options Page Optional Ports Piston Accumulators Series 4000 The following ports are available as options on all piston accumulators.10 1.875 2½ 1.125 1½ 1.1 — — — — — C F A (4 places) x G Min. Spec. SAE 4-Bolt Flange Dimensions Code 62 (ISO 6162) (thru 2" diameter) – 6000 PSI (410 Bar) Flange Size in mm 1½" 38 2" 50 2½" — SAE Flange Dimensions (in.9 M20 44. dimensions are shown below.5 79.500 7/8 . Code Bore YA 2" YB 2" YC 2" YD 2" YE 3" YF 3" — — Port Size 1" 1¼" 1½" 2" — — — Min.4 38 34.375 3/4 .625 Metric ISO 6162 Flange Dimensions (mm) A B C F G M16 36. SAE Straight Thd. Size Code Bore #5 TA 2" #6 TB 2" #8 TC 2" #10 TI 2" #12 TD 2" #16 TE 3" — — — Code 62 Flange Port Code Inch Metric PG MG PH MH PP MV PQ MQ — — — — — — NPT Port Code UT UU UV UW UX UY UZ BSPP Port Code RA RB RC RD RE RF RG ISO 6149-1 Port Min.11 1.438 3.750 3. Illinois USA . 2-1/2" to “Socket Weld Flange Adapter Pattern”. Depth B Gas Valve Option (M) A heavy duty (military style) poppet-type gas valve cartridge (Mil. Bore 2" 2" 2" 3" 3" 4" 4” Port Size 3/8" 1/2" 3/4" 1" 1¼" 1½" 2” Min. 2) BSPT and Metric ports available.) A B C F G 5/8 . MS28889-2) is available as an option (M) – specify when ordering. Bore 4" 4" 6" 6" — — — Port Size 3/8" 1/2" 3/4" 1" 1¼" 1½" 2” Min. 95 3.. Illinois USA . Nitrile Recommended Operating Temperature Range -20°F to 165°F -29°C to 74°C -10°F to 250°F -23°C to 121°C -40°F to 250°F -40°C to 121°C -25°F to 320°F -32°C to 160°C -45°F to 185°F -43°C to 85°C Maximum Temperature with Reduced Life 200°F 93°C 400°F 204°C 300°F 149°C 350°F 177°C 200°F 93°C General Application and Compatibility* Parker's Standard Compound – Compatible with most mineral oil-based fluids Compatible with most mineral oil-based fluids at higher temperatures and some exotic fluids Compatible with most phosphate ester fluids and some synthetic fluids Compatible with most oil-based and biodegradable fluids. Safety fuses can be installed on all piston accumulators by using a fuse adapter.Catalog HY10-1630/US Page Options Safety Fuse Options (F) Safety Fuses are used as a safety device on accumulators and gas bottles to prevent over-pressurization of gas due to external heat or hydraulic pressure (set at 140% of maximum system pressure to avoid rupture disk fatigue and premature failure).48 #5 SAE Straight Port Th’d Fuse Adapter 1) Assembly includes housing and rupture disk.25 Fuse 1. 47 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Description Safety Fuse Assembly1 Replacement Rupture Disks Fuse Adapter Part Number 086471xxxx 756003xxxx 1468970002 Piston Accumulators Series 4000 Piston 5000 4000 3000 1. xxxx = pressure setting in 100 psi increments. order P/N 0864712000.77 1. Temperature ranges may vary depending upon fluid used in hydraulic system. Seal Material Options Seal Code K E D H Q Polymer Buna Nitrile Fluorocarbon Elastomer Ethylene Propylene Hydrogenated Nitrile Low Temp. Modifications include electroless nickel plating all surfaces and metal parts. The rupture disks are calibrated to rupture at a pre-determined pressure. see “How to Order.e.44 0. maintains sealing effectiveness at a wide range of temperatures Compatible with most mineral oil-based fluids and maintains sealing effectiveness at low temperatures *Note: Consult local distributor or factory for fluid compatibility information. i.55 #8 SAE Straight Port Th’d #8 SAE 3/4-16 UNF-2A #5 SAE Straight Port Th’d 0. for an assembly with a 2000 PSI setting. Water Service Option (W) Piston accumulators are available for use with water as the fluid media. Safety fuses are available on most sizes of piston accumulators. 4" bore units and above can be equipped with a fuse port machined in the gas cap by specifying the “Safety Fuse Option” (F) at the time of order in the model code.” The safety fuse assembly and/or fuse adapter must be ordered separately.70 0. Some example of Parker’s past special designs include: • • • • • • • Special and Stainless Steel Materials Piston Position and Velocity Sensors and Switches Special Seals Non-Standard Capacities Tie Rod Construction Special Certifications Spring & Weight Loaded Consult the experts at Parker with your next piston accumulator requirement! 48 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 6. charging and gauging accessories. 7.” Special Options If your application requires a piston accumulator. Illinois USA . Parker representative. or special option that falls outside of Parker’s broad offering. See “Accumulator Accessories. consult your local distributor.Catalog HY10-1630/US Parts Page Parts List — Hydraulic Accumulators Piston Accumulators Series 4000 Item 1 2 3 4 5 5A 6 7 7A 8 8A 9 9A Part Description Body Hydraulic Cap Gas Cap Piston V-O-Ring V-O-Ring Back-Up Washers PTFE Ring (Piston) O-Ring O-Ring Back-Up Washer Gas Valve w/High Pressure Core Gas Valve O-Ring Gas Valve Guard Screw 4000 PSI Seal Kit Numbers (Includes items 5. from simple modifications of standard units to complete designs. gas bottle. 7A. 8A) Material Buna-Nitrile (Std.) Fluorocarbon EPR Hydrogenated Nitrile Low Temp Nitrile 2" RK0200K000 RK0200E000 RK0200D000 RK0200H000 RK0200Q000 Bore Size 3" 4" RK0300K000 RK0400K000 RK0300E000 RK0400E000 RK0300D000 RK0400D000 RK0300H000 RK0400H000 RK0300Q000 RK0400Q000 6" RK0600K000 RK0600E000 RK0600D000 RK0600H000 RK0600Q000 Mounting. or the factory with your specific requirements. 5A. Charging & Gauging Accessories Parker offers a wide variety of mounting. Parker has the manufacturing and engineering expertise to design and build piston accumulators to your exacting requirements. in. 4”. (5.90 liters) 0183 183 cu. 6” U NPTF (Not Recommended) Options Blank W F G M L P R Standard Gas Cap Water Service SAE Fuse Port * SAE Fuse Port * – Water Service MS28889-2 Gas Valve MS28889-2 Gas Valve.11 2” 2” 2” 2” 2” 4” 4” Metric/ISO 6149-1 A M14 x 1.12) E SAE #16 (1 5/16 .4 liters) 2310 10 gal.11 F 1 1/2 . Bore Size 2” 2” 2” 2” 3” 2” Min. (1.95 liters) 0090 3” 90 cu. in. (0.69 liters) 0578 2½ gal. (3.79 liters) 0347 1½ gal.47 liters) 0116 116 cu. Nominal Bore Type of Size Construction Options Series Capacity Design Pressure Design Number Seal Compound Hyd. (37. (1. (1.20) B SAE #6 (9/16 . in.11 E 1 1/4 .9 liters) 1733 7½ gal. (15.48 liters) 0058 58 cu.79 liters) 0347 1½ gal. (28. in. Port K T C U V SAE #8 Hyd.5 D M27 x 2 E M33 x 2 F M42 x 2 Example of Optional Port Accumulator A 4 N 0231 E 3 Non-std. (0. Order fuse assembly separately. A SAE #5 (1/2 .47 liters) 0231 1 gal.00 liters) 0058 58 cu.08 liters) 0010 10 cu. (3.9 liters) Consult factory for other available sizes. Bore 4” 4” 6” 6” Nominal Bore Size 2 3 4 6 2 inches 3 inches 4 inches 6 inches Blank Std. (0. Design Number 1 2 Standard Metric Mounting Holes & Hyd. Illinois USA .14 D 1 . Special Seals (to be specified) 3 *** 49 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. (3.25 liters) 0029 29 cu.5 C M22 x 1.90 liters) 0231 4” 1 gal. in. See Port Modifications Table) Special Design Standard Ports Available (See Port Modifications Table if Using Other Than Standard Ports Shown Below) Bore Size 2” 3” 4” 6” 4000 PSI Port Sizes Standard Metric (BSPP) SAE #12 SAE #12 SAE #16 SAE #16 3/4 3/4 1 1 Seal Compound (See Catalog for Temperature Settings) K E D H Q S Buna Nitrile (Std) Fluoroelastomer EPR Hydrogenated Nitrile Low Temp. (0. in. in.16) D SAE #12 (1 1/16 .14) 6000 PSI (Code 62) G 1” H 1 1/4” P 1 1/2” Q 2” Type of Construction N Threaded both ends non-ASME material standard on 2”. in.18) C SAE #8 (3/4 .11 G 2 . Water Service Fuse* and MS28889-2 Fuse* and MS28889-2. Hydraulic and Gas Port Modifications Designated by 2 Digits 1st Digit Style 2nd Digit Description Min.16 liters) 0015 2” 15 cu. in. Select only those symbols that represent the features desired. Water Service Design Pressure E 4000 PSI R BSPP Parallel B BSPT Taper Port G Metric Y ISO 6149-1 T 3/8” U 1/2” V 3/4” W 1” X 1 1/4” Y 1 1/2” Z 2” BSPP/BSPT A 3/8 .1 liters) 1155 5 gal. Port Modification Gas Port Modification A 4 N – 0231 E 1 K – – – – Series A B Accumulator Gas Bottle Bore Size/Capacity 0005 5 cu. (0.5 B M18 x 1. in. Port NPT 3/4” Gas Port * Safety fuse assembly not included. (9. or Gas. (5. 3”. (9. Port (BSPP Standard) Specify Optional Ports Optional Port (Hyd.95 liters) 0116 116 cu.14 C 3/4 .12) I SAE #10 (7/8 .95 liters) 0029 29 cu. in.47 liters) 0924 6” 4 gal.19 B 1/2 . in. (18.69 liters) 0578 2½ gal. (0. and place them in the sequence indicated by the example at the top of the chart. (0. T SAE Straight Thread Ports P Flange Code 62 M Metric Flange per ISO 6162 Blank Std. (0.Catalog HY10-1630/US Page Ordering Information Piston Accumulators Series 4000 How to Order Series 4000 Piston Accumulators Piston accumulators and gas bottles can be specified by using the symbols in the chart below to develop a model number.48 liters) 0058 58 cu. Catalog HY10-1630/US Page Piston Accumulators Series 5000 Series 5000 Piston Accumulators • Heavy Duty Service with 5000 PSI Operating Pressure • 2" thru 9" Bores with Over 30 Standard Capacities • Patented V-O-ring Piston Seals • Serviceable Threaded End Construction • Five Standard Seal Options to Handle a Variety of Fluids and Temperatures • ASME Certification and CE Marking Available 50 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . 03 102 5. or the factory with your specific requirements.2 4. Available Options If your application requires a piston accumulator. Parker has the manufacturing and engineering expertise to design and build piston accumulators to your exacting requirements. must be calculated with ample margins to store the required fluid.78 147 7.) (mm) 2. port & fitting size will become limiting factors for most applications.4 3. For pressures over 5000 psi.6” Bores) Military Style (MS) Gas Valve (7” . especially large capacity sizes. MS28889-2) as standard.) 2 3 4 6 7 9 Actual Bore Size (in.00 76. Piston travel.00 229 Max. Standard Ports The following ports are supplied as standard on all fluid ends and on the gas end of accumulators ordered for use with gas bottles: Standard Ports Metric Models Standard Models BSPP Port (in) SAE #12 3/4 SAE #12 3/4 SAE #16 1 SAE #16 1 2” Code 62 Flange 2” Metric ISO 6162 Flange 2” Code 62 Flange 2” Metric ISO6162 Flange Bore Size 2 3 4 6 7 9 51 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. consult your local distributor. In some cases. consult the factory.Catalog HY10-1630/US Page Specifications Materials • • • • • • • • Shell – high strength alloy steel Caps – steel Pistons – aluminum (2" thru 7"). Parker representative. from simple modifications of standard units to complete designs. For specific precharge pressures. gas bottle. Gas Valve with High Pressure Core (2” . Spec. a piston accumulator and gas bottle combination may be more economical.9” Bores) Actual Bore Sizes & Maximum Flow Rates Pressure Ratings Nominal Bore Size (in.00 178 9. Standard accumulators (with nitrile seals) may be used with petroleum-based industrial oils or water-based flame resistant fluids. Optional seals compatible with most industrial fluids are available with temperature ranges from -45°F to 325°F (-43°C to 162°C). Some example of Parker’s past special designs include: • • • • • • • • Special and Stainless Steel Materials Piston Position and Velocity Sensors and Switches Special Seals Non-Standard Capacities Water Service Ports Fixed Gauge Mounts Fuse Plug Assemblies Series 5000 piston accumulators are rated at minimum 4 to 1 design factors. or special option that falls outside of Parker’s broad offering.03 51. *Note: Based on 120 in/sec maximum piston speed. Auxiliary Gas Bottles When space does not permit the installation of the required piston accumulator. a smaller accumulator may be used by connecting it to an auxiliary gas bottle(s) that can be located in a nearby spot where space is available. Recommended Flow* GPM LPM 100 380 220 834 397 1504 818 3096 1199 4538 1982 7502 #5 SAE THREAD 1/2–20 UNF-2A 1/2–20 UNF-2A Note: The standard Parker gas cap will accept either style gas valve. Models with 7” and 9” bores are supplied with a heavy duty (military) poppet-type gas valve cartridge (Mil. specify at the time of order. ductile iron (9") Gas Valve Cartridge – steel Gas Valve Protector – steel Piston Glide Rings – PTFE Piston & End Seals – various polymers Piston Seal Backups – PTFE Piston Accumulators Series 5000 Gas Valve Series 5000 accumulators and gas bottles with 2” through 6” bores are supplied with a high pressure cored gas valve as standard. Illinois USA . Precharge Units are shipped with a nominal nitrogen precharge as standard. confined to the accumulator. Fluids Parker’s piston accumulators are compatible with a wide variety of fluids. 1-1/2 Gal.25 1.62 54.5 16. 1-1/2 Gal.34 18. 7-1/2 Gal.76 8.13 12 1-1/16 . Oil Service A2N0005C1K A2N0010C1K A2N0015C1K A2N0029C1K A2N0058C1K A3N0029C1K A3N0058C1K A3N0090C1K A3N0116C1K A3N0183C1K A4N0058C1K A4N0116C1K A4N0231C1K A4N0347C1K A4N0578C1K A6N0231C1K A6N0347C1K A6N0578C1K A6N0924C1K A6N1155C1K A6N1733C1K A6N2310C1K Fluid Volume (gal) – – – 1 Pint 1 Quart 1 Pint 1 Quart 1.62 32.5 11.81 19.06 16.25 14.13 16 1-5/16 .43 98. Capacities & Dimensions Piston Accumulators Series 5000 Small Bore 5000 PSI Piston Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth High Pressure Cored Gas Valve A Threaded Port Configuration F Dia.5 59.19 10.43 C (in) SAE No.12 2.75 Notes: 1) For Water Service add “W” after construction code.19 23. 2-1/2 Gal.20 4.31 9. 2) See “Port Options” for complete listing of port options.43 45.75 52.94 22. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 6 7 8 11 17 21 28 35 40 55 43 54 77 100 146 128 148 190 252 293 396 499 2. 5 Gal.38 0.12 3/4 – – – 4. 3 Liter 1 Quart 1/2 Gal.12 1 1/2 .20 3.78 14.00 1.50 1.18 23.75 7.5 30.12 3/4 3/8 .62 34. Illinois USA .Catalog HY10-1630/US Page Models. 2-1/2 Gal. 3) ASME certified and CE marked accumulators and gas bottles available.12 1 1/2 . 1 Gal. 4 Gal.25 0.43 76. 10 Gal. see “How to Order”.56 5.13 16 1-5/16 .62 25.06 12 1-1/16 .06 12.5 34 63 95 121 188 68 126 241 357 588 266 382 613 959 1190 1768 2345 D-Hydraulic Port A (in) B (in) 6. 1 Gal.25 0.63 1. (cu in) 5 10 15 29 58 29 58 90 116 183 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (cu in) 6.5 Liter 1/2 Gal. Bolt Circle Flanged Port Configuration D Hydraulic Port C B Model No.56 32. 52 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. D Port A (in) B (in) 12. 1-1/2 Gal. 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (cu in) 68 126 241 357 588 266 382 613 959 1190 1768 2345 A (in) B (in) 10.12 1 1/2 . 1 Gal.75 52.20 3. 7-1/2 Gal.49 53.05 22.38 0.43 Actual (cu in) 86 144 259 375 606 319 435 666 1012 1243 1821 2398 C (in) SAE No.43 76. 4 Gal.93 15. 1 Gal.75 5000 PSI Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure Cored Gas Valve A Threaded Port Configuration Model No.75 7.12 1 1/2 .12 1 1/2 . 1-1/2 Gal. 7-1/2 Gal.30 97. Illinois USA .25 16 1-5/16 . 5 Gal. Thread Size (in) Tube Size E (in) F (in) G (in) Weight (lbs) 41 53 75 98 144 123 143 185 250 288 391 494 5.06 16. 2-1/2 Gal. 5 Gal. Gas Bottle B4N0058C1K B4N0116C1K B4N0231C1K B4N0347C1K B4N0578C1K B6N0231C1K B6N0347C1K B6N0578C1K B6N0942C1K B6N1155C1K B6N1733C1K B6N2310C1K F Dia. Bolt Circle Flange Port Configuration D Hydraulic Port C B Gas Volume Nominal (gal) 1 Quart 1/2 Gal.38 0.13 16 1-5/16 .49 33.12 1 1/2 . 4 Gal.43 45.62 34.18 23.75 53 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.68 18. 10 Gal. 2-1/2 Gal.Catalog HY10-1630/US Page Models. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No. 1-1/2 Gal. 10 Gal.13 16 1-5/16 . Size (in) Size E (in) F (in) G (in) Weight (lbs) 43 54 77 100 146 128 148 190 252 293 396 499 5.30 44. 1-1/2 Gal.25 1. A4N0058C3KTETE A4N0116C3KTETE A4N0231C3KTETE A4N0347C3KTETE A4N0578C3KTETE A6N0231C3KTETE A6N0347C3KTETE A6N0578C3KTETE A6N0924C3KTETE A6N1155C3KTETE A6N1733C3KTETE A6N2310C3KTETE Fluid Volume (gal) (cu in) 1 Quart 1/2 Gal. 2-1/2 Gal.25 0.62 51.30 75.49 31.20 4. 2-1/2 Gal.49 24.62 32.30 D Port (Both Ends) SAE Thread Tube No.20 4.50 1.62 25. 1 Gal.62 54.25 0.50 16 1-5/16 .20 3.75 7. Capacities & Dimensions Piston Accumulators Series 5000 Small Bore 5000 PSI Piston Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia.43 98. 1 Gal.81 19. 00 15.11 0.47 3.56 1.95 1.26 10.90 (cu in) 5 10 15 29 58 29 58 90 116 183 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (Liters) 0.9 45.90 3.11 2.7 5.25 0.79 5. Oil Service A2N0005C2K A2N0010C2K A2N0015C2K A2N0029C2K A2N0058C2K A3N0029C2K A3N0058C2K A3N0090C2K A3N0116C2K A3N0183C2K A4N0058C2K A4N0116C2K A4N0231C2K A4N0347C2K A4N0578C2K A6N0231C2K A6N0347C2K A6N0578C2K A6N0924C2K A6N1155C2K A6N1733C2K A6N2310C2K Fluid Volume (Liters) 0.90 28.4 66.5 15.6 34.48 0.08 1.40 D-Hydraulic Port A (mm) B (mm) 172 211 248 360 589 260 364 481 573 814 306 422 651 883 1341 487 600 824 1159 1383 1941 2500 C (mm) BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 2.3 86.24 0.98 3.69 9. Capacities & Dimensions Piston Accumulators Series 5000 Small Bore 345 Bar Metric Piston Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth High Pressure Cored Gas Valve A Threaded Port Configuration F Dia.90 3.16 0.47 1.64 4.08 0. see “How to Order”.6 9.47 15.50 29.69 9.70 19.40 37.48 0.2 57.95 5.Catalog HY10-1630/US Page Models.00 0.2 3.7 18.10 18.3 25. 54 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.79 5. Illinois USA .98 0.0 7.0 19.4 24.03 1.9 67. 2) See “Port Options” for a complete listing of port options.85 9.56 1. 3) ASME certified and CE marked accumulators and gas bottles are available.00 38.95 0.95 1.50 0.06 3.36 6.8 3.0 114 133 180 227 67 27 3/4 – – – – 102 29 3/4 – M10 60 15 134 29 1 – M12 82 18 191 29 1 – M12 110 18 Notes: 1) For Water Service add “W” after construction code.6 12. Bolt Circle Flanged Port Configuration D Hydraulic Port C B Model No.19 0. 6 34.6 65.90 28.2 44.9 34.47 15.70 19.6 65.0 114 133 180 227 134 1 – M12 82 18 191 1 – M12 110 18 345 Bar Metric Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure Cored Gas Valve A Threaded Port Configuration Model No.69 9.95 1.40 37.10 18.40 D .9 45.64 4.90 3. Illinois USA . Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.06 3. A4N0058C2KRDRD A4N0116C2KRDRD A4N0231C2KRDRD A4N0347C2KRDRD A4N0578C2KRDRD A6N0231C2KRDRD A6N0347C2KRDRD A6N0578C2KRDRD A6N0924C2KRDRD A6N1155C2KRDRD A6N1733C2KRDRD A6N2310C2KRDRD Fluid Volume (Liters) 0.79 5.9 67.69 9.11 2.95 5. Gas Bottle B4N0058C2K B4N0116C2K B4N0231C2K B4N0347C2K B4N0578C2K B6N0231C2K B6N0347C2K B6N0578C2K B6N0924C2K B6N1155C2K B6N1733C2K B6N2310C2K F Dia.8 112 131 177 224 134 29 1 – M12 82 18 191 29 1 – M12 110 18 55 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.47 15.85 9.6 23.00 15.Port (Both Ends) A (mm) B (mm) 277 393 622 854 1312 458 571 795 1130 1354 1912 2471 BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 19.3 86.40 A (mm) B (mm) 306 422 651 883 1341 487 600 824 1159 1383 1941 2500 C (mm) D-Hydraulic Port BSPP/G (in) SAE Flange E (mm) F (mm) G (mm) Weight (Kg) 18.90 (cu in) 58 116 231 347 578 231 347 578 924 1155 1733 2310 Gas Volume (Liters) 1.85 9.47 3.69 9.00 15.2 57.95 1.79 5.26 10.26 10.Catalog HY10-1630/US Page Models.4 55.50 29.79 5.90 28.0 83. Capacities & Dimensions Piston Accumulators Series 5000 Small Bore 345 Bar Metric Piston Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia. Bolt Circle Flange Port Configuration D Hydraulic Port C B Gas Volume Nominal (liters) 0.69 9.47 3.90 3.00 38.36 6.4 66.64 4.10 18.36 6.40 37.90 Actual (liters) 1.00 38.50 29.95 5.11 2.70 19.4 24.79 5.06 3. 94 11.43 C (in) D Hydraulic Port 2" SAE Code 62 Flange2 E (in) F (in) G (in) Weight (lbs) 385 495 611 837 831 1064 1298 1532 1765 1.50 50.Catalog HY10-1630/US Page Models. Illinois USA . 2) See “Port Options” for a complete listing of port options.09 ±0. Bolt Circle Flange Port Configuration D Hydraulic Port C B Fluid Volume Model No. A7K1155C1K A7K1733C1K A7K2310C1K A7K3465C1K A9K2310C1K A9K3465C1K A9K4620C1K A9K5775C1K A9K6930C1K (gal) 5 Gal.78 ±0.00 1. see “How to Order”.75 0.25 123.13 Notes: 1) For Water Service add “W” after construction code.50 57.94 87. 3) ASME certified and CE marked accumulators and gas bottles are available.18 5. 25 Gal. 10 Gal. 15 Gal.63 5/8 . 7-1/2 Gal. (cu in) 1155 1733 2310 3465 2310 3465 4620 5775 6930 Gas Volume (cu in) 1190 1768 2345 3520 2400 3555 4710 5865 7020 A (in) 9.12 105.06 B (in) 42.50 72. The Minimum Design Metal Temperature (MDMT) for ASME certified piston accumulators presented in this section is 20°F (-7°C). 10 Gal. 20 Gal.50 102. 56 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.09 1. Capacities & Dimensions Piston Accumulators Series 5000 Large Bore 5000 PSI Piston Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth High Pressure MS28889-2 Gas Valve A Threaded Port Configuration F Dia. 15 Gal.63 2" SAE Code 62 Flange2 3/4-16 7.75 68. 30 Gal. 63 2” SAE Code 62 3/4 . Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.09 ±0.87 70.13 5000 PSI Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure MS28889-2 Gas Valve A Threaded Port Configuration F Dia. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.50 102.78 ±0.62 121.50 50.75 0.31 85.12 105.18 5.Catalog HY10-1630/US Page Models. 15 Gal. 20 Gal.50 57. 25 Gal.09 1.25 123. Illinois USA .06 B (in) 42.16 7.49 103.94 11. 25 Gal. Actual (cu in) 1155 1733 2310 3465 2310 3465 4620 5775 6930 A (in) 9.87 49. 15 Gal.43 C (in) D Hydraulic Ports E (in) F (in) G (in) Weight (lbs) 376 489 602 828 782 1016 1250 1483 1717 1.06 B (in) 40. Capacities & Dimensions Piston Accumulators Series 5000 Large Bore 5000 PSI Piston Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia.12 67. 30 Gal.00 1.87 55. A7K1155C3KPQPQ A7K1733C3KPQPQ A7K2310C3KPQPQ A7K3465C3KPQPQ A9K2310C3KPQPQ A9K3465C3KPQPQ A9K4620C3KPQPQ A9K5775C3KPQPQ A9K6930C3KPQPQ Fluid Volume (gal) (cu in) 5 Gal. Gas Bottle B7K1155C1K B7K1733C1K B7K2310C1K B7K3465C1K B9K2310C1K B9K3465C1K B9K4620C1K B9K5775C1K B9K6930C1K Gas Volume Nominal (gal) 5 Gal.09 2” SAE Code 62 3/4-16 7. 1155 1733 2310 3465 2310 3465 4620 5775 6930 Gas Volume (cu in) 1190 1768 2345 3520 2400 3555 4710 5865 7020 A (in) 9.13 57 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 15 Gal. 10 Gal. 7-1/2 Gal.80 D Port (Both Ends) E (in) F (in) G (in) Weight (lbs) 385 495 611 837 831 1064 1298 1532 1765 2” SAE Code 62 5/8-18 5.78 ±0.63 2” SAE Code 62 5/8 .09 ±0.94 11.75 0.94 87. 10 Gal. 10 Gal. 15 Gal. 10 Gal. 30 Gal.00 1.87 100. 7-1/2 Gal.50 72. 20 Gal.75 68. 75 113.90 56.33 77.80 94.3 41 2” Metric SAE Code 62 Flange2 M19 178 29 Notes: 1) For Water Service add “W” after construction code.1 ±1. 2) See “Port Options” for a complete listing of port options. 58 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.85 75.18 A (mm) 231.37 58. A7K1155C2K A7K1733C2K A7K2310C2K A7K3465C2K A9K2310C2K A9K3465C2K A9K4620C2K A9K5775C2K A9K6930C2K (Liters) 18.50 29.23 115.90 56.2 ±2.85 37.90 28. Capacities & Dimensions Piston Accumulators Series 5000 Large Bore 345 Bar Metric Piston Accumulators for Oil and Water Service 3 Mounting Holes E Thread G Depth High Pressure MS28889-2 Gas Valve A Threaded Port Configuration F Dia.40 37.5 B (mm) 1080 1461 1842 2604 1289 1751 2213 2673 3135 C (mm) D Hydraulic Port 2" Metric SAE Code 62 Flange2 E (mm) F (mm) G (mm) Weight (kg) 175 226 277 380 377 483 589 695 801 41 M16 146 24 299.27 96.00 38.Catalog HY10-1630/US Page Models.75 39. Illinois USA . 3) ASME certified and CE marked accumulators and gas bottles are available.40 57. see “How to Order”. Bolt Circle Flange Port Configuration D Hydraulic Port C B Fluid Volume Model No.70 (cu in) 1155 1733 2310 3465 2310 3465 4620 5775 6930 Gas Volume (liters) 19. 27 96.3 2” Metric SAE Code 62 Flange2 M19 178 29 345 Bar Metric Auxiliary Gas Bottles 3 Mounting Holes E Thread G Depth High Pressure MS28889-2 Gas Valve A Threaded Port Configuration F Dia.90 28.90 56.90 56.50 29.18 A (mm) 231.3 41 2” Metric SAE Code 62 Flange2 M19 178 29 1) For Water Service add “W” after construction code. Capacities & Dimensions Piston Accumulators Series 5000 Large Bore 345 Bar Metric Piston Accumulators for Use with Gas Bottles Typical Both Ends 3 Mounting Holes E Thread G Depth D Gas Port A F Dia.00 38.18 A (mm) 231.75 39.Catalog HY10-1630/US Page Models.37 58. Illinois USA .1 ±1.37 58.27 96.23 115. 2) See page 60 for complete listing of port options.5 B (mm) 1039 1420 1801 2563 1248 1710 2172 2632 3098 D Port (Both Ends) 2” Metric SAE Code 62 Flange2 E (mm) F G (mm) (mm) Weight (kg) 175 226 277 380 377 483 589 695 801 M16 146 24 299.85 75.33 77.2 ±2. Bolt Circle Flange Port Configuration D Hydraulic Port C B Model No.85 37.33 77.23 115.00 38.40 57.50 29.70 1155 1733 2310 3465 2310 3465 4620 5775 6930 Gas Volume (Liters) 19.90 56.75 113.85 75.85 37.40 57.2 ±2.70 Actual (Liters) 19.75 113.90 56. A7K1155C2KMQMQ A7K1733C2KMQMQ A7K2310C2KMQMQ A7K3465C2KMQMQ A9K2310C2KMQMQ A9K3465C2KMQMQ A9K4620C2KMQMQ A9K5775C2KMQMQ A9K6930C2KMQMQ Fluid Volume (Liters) (cu in) 18.80 94.75 39.40 37. Bolt Circle Threaded Port Configuration Flange Port Configuration D Hydraulic Port B Accumulator Model No.80 94. see “How to Order”.40 37. Gas Bottle B7K1155C2K B7K1733C2K B7K2310C2K B7K3465C2K B9K2310C2K B9K3465C2K B9K4620C2K B9K5775C2K B9K6930C2K Notes: Gas Volume Nominal (Liters) 18.90 28.5 B (mm) 1080 1461 1842 2604 1289 1751 2213 2673 3135 C (mm) D Hydraulic Ports 2” Metric SAE Code 62 Flange2 E (mm) F G (mm) (mm) Weight (kg) 171 222 273 376 355 461 567 673 779 41 M16 146 24 299.1 ±1. 59 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Size Code Bore #5 TA 2" #6 TB 2" #8 TC 2" #10 TI 2" #12 TD 2" #16 TE 3" — — — Code 62 Flange Port Code Inch Metric PG MG PH MH PP MV PQ MQ PR — PS — — — NPT Port Code UT UU UV UW UX UY UZ BSPP Port Code RA RB RC RD RE RF RG ISO 6149-1 Port Min. Nitrile Maximum Temperature with Reduced Life 200°F 93°C 400°F 204°C 300°F 149°C 350°F 177°C 200°F 93°C General Application and Compatibility* Parker's Standard Compound – Compatible with most mineral oil-based fluids Compatible with most mineral oil-based fluids at higher temperatures and some exotic fluids Compatible with most phosphate ester fluids and some synthetic fluids Compatible with most oil-based and biodegradable fluids.10 1. Illinois USA . consult factory. For the Minimum Design Metal Temperature (MDMT) of ASME certified accumulators. Port Port Min.1 — — — — — C F A (4 places) x G Min.625 Metric SAE Flange Dimensions (mm) A B C F G M16 36. 2-1/2" to “Socket Weld Flange Adapter Pattern”.312 4. Bore 2" 2" 2" 3" 3" 4" 4” Port Size 3/8" 1/2" 3/4" 1" 1¼" 1½" 2” Min. SAE Straight Thd. 60 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. not the accumulator. 2) BSPT and Metric ports available.750 3.812 2 1.Catalog HY10-1630/US Page Options Optional Ports Piston Accumulators Series 5000 The following ports are available as options on all piston accumulators. refer to page 56.438 3. Bore 4" 4" 6" 6" 7" 9” — Port Size 3/8" 1/2" 3/4" 1" 1¼" 1½" 2” Min.375 3/4 .500 7/8 .5 96. Depth B Seal Material Seal Code K E D H Q Operating Temperature Range -20°F to 165°F -29°C to 74°C -10°F to 250°F -23°C to 121°C -40°F to 250°F -40°C to 121°C -25°F to 320°F -32°C to 160°C -45°F to 185°F -43°C to 85°C **Recommended Polymer Buna Nitrile Fluorocarbon Elastomer Ethylene Propylene Hydrogenated Nitrile Low Temp. Temperature ranges may vary depending upon fluid used in hydraulic system.4 38 34.9 2. maintains sealing effectiveness at a wide range of temperatures Compatible with most mineral oil-based fluids and maintains sealing effectiveness at low temperatures * Note: Consult local distributor or factory for fluid compatibility information. SAE 4-Bolt Flange Dimensions Code 62 (ISO 6162) (thru 2" diameter) – 6000 PSI (410 Bar) Flange Size in mm 1½" 38 2" 50 2½" — SAE Flange Dimensions (in.5 79.125 1½ 1.) A B C F G 5/8 .875 2½ 1.8 50 38. ** The temperature listed indicates the operating temperature range of the seals.9 M20 44. Bore 2" 2" 2" 3" 3" 4" 4” Port Size M14 M18 M22 M27 M33 M42 — Notes: 1) 1" thru 2" flanges are to standard SAE Code 62 dimensions. Code Bore YA 2" YB 2" YC 2" YD 2" YE 3" YF 3" — — Port Size 1" 1¼" 1½" 2" 2½" 3” — Min.11 1. dimensions are shown below. Metric pattern supplied on 345 Bar Metric units unless otherwise specified. order P/N 0864712000. Modifications include electroless nickel plating all surfaces and metal parts.. Safety fuses are available on most sizes of piston accumulators. The rupture disks are calibrated to rupture at a pre-determined pressure.” The safety fuse assembly and/or fuse adapter must be ordered separately. Illinois USA . xxxx = pressure setting in 100 psi increments. 4" bore units and above can be equipped with a fuse port machined in the gas cap by specifying the “Safety Fuse Option” (F) at the time of order in the model code. 61 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. MS28889-2) is available as an option (M) – specify when ordering.95 #5 SAE Straight Port Th’d 1.48 #5 SAE Straight Port Th’d Fuse Adapter 1) Assembly includes housing and rupture disk. i. L07689000* Safety Fuse Options (F) Safety Fuses are used as a safety device on accumulators and gas bottles to prevent over-pressurization of gas due to external heat or hydraulic pressure (set at 140% of maximum system pressure to avoid rupture disk fatigue and premature failure).44 Description Safety Fuse Assembly1 Replacement Rupture Disks Fuse Adapter Part Number 086471xxxx 756003xxxx 1468970002 3. for an assembly with a 2000 PSI setting.55 #8 SAE 3/4-16 UNF-2A 1.70 0. Fuse 1. Note: This valve is standard on 7” and 9” bore sizes.77 0. Safety fuses can be installed on all piston accumulators by using a fuse adapter. Piston Accumulators Series 5000 Piston 5000 4000 3000 Military Style (MS) Gas Valve 1/2–20 UNF-2A Optional Military Style Gas Valve (M) 2” thru 6” Bore Sizes A heavy duty (military style) poppet-type gas valve cartridge (Mil.Catalog HY10-1630/US Page Options & Parts Water Service Option (W) Piston accumulators are available for use with water as the fluid media.e. see “How to Order. Spec.25 #8 SAE Straight Port Th’d 0. 6. Parker has the manufacturing and engineering expertise to design and build piston accumulators to your exacting requirements. 7. Some example of Parker’s past special designs include: • • • • • • • Special and Stainless Steel Materials Piston Position and Velocity Sensors and Switches Special Seals Non-Standard Capacities Tie Rod Construction Special Certifications Spring & Weight Loaded Consult the experts at Parker with your next piston accumulator requirement! 62 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 5A. charging and gauging accessories. 7A. consult your local distributor. or special option that falls outside of Parker’s broad offering. or the factory with your specific requirements.Catalog HY10-1630/US Page Parts Parts List — Hydraulic Accumulators Piston Accumulators Series 5000 Item 1 2 3 4 5 5A 6 7 7A 8 8A 9 9A Part Description Body Hydraulic Cap Gas Cap Piston V-O-Ring V-O-Ring Back-Up Washers PTFE Ring (Piston) O-Ring O-Ring Back-Up Washer Gas Valve Gas Valve O-Ring Gas Valve Guard Screw 5000 PSI Seal Kit Numbers (Includes items 5. Parker representative. Illinois USA . See “Accumulator Accessories. gas bottle. from simple modifications of standard units to complete designs. 8A) Material Buna-Nitrile (Std.) Fluorocarbon EPR Hydrogenated Nitrile Low Temp Nitrile 2" RK0200K000 RK0200E000 RK0200D000 RK0200H000 RK0200Q000 3” RK0300K000 RK0300E000 RK0300D000 RK0300H000 RK0300Q000 Bore Size 4" 6" RK0400K000 RK0600K000 RK0400E000 RK0600E000 RK0400D000 RK0600D000 RK0400H000 RK0600H000 RK0400Q000 RK0600Q000 7" RK0700K000 RK0700E000 RK0700D000 RK0700H000 RK0700Q000 9" RK0900K000 RK0900E000 RK0900D000 Consult Factory RK0900Q000 Mounting.” Special Options If your application requires a piston accumulator. Charging & Gauging Accessories Parker offers a wide variety of mounting. approval stamp 7” & up.14 D 1 . (3.1 liters) 5 gal.11 G 2 . ( 18. in.95 liters) 116 cu. or Gas.9 liters) 7½ gal.08 liters) 10 cu. Port Modification Gas Port Modification A 7 K – 2310 C 1 K – – – – Series A B Accumulator Gas Bottle 0005 0010 0015 0029 0058 0029 0058 0090 0116 0183 0058 0116 0231 0347 0578 0231 0347 0578 0924 1155 1733 2310 1155 1733 2310 3465 2310 3465 4620 5775 6930 Bore Size/Capacity 5 cu.90 liters) 183 cu.4 liters) 10 gal.14 C 3/4 .48 liters) 58 cu. Not available with metric flange.5 C M22 x 1.12) G SAE #24 (1 7/8 .20) B SAE #6 (9/16 . in.48 liters) 58 cu. in.90 liters) 1 gal. (0. (3.12) H SAE #32 (2 1/2 . (18. K 7” U NPTF (Not Recommended) L 9” E Consult factory for other available sizes.8 liters) 10 gal.95 liters) 29 cu.9 liters) 15 gal.11 F 1 1/2 . Select only those symbols that represent the features desired.S.00 liters) 58 cu. (0.47 liters) 4 gal. Water Service 5000 PSI 350 Bar (CE marked only) Example of Optional Port Accumulator A 4 N 0231 C 3 Non-std.4 liters) 10 gal.12) E SAE #16 (1 5/16 .11 E 1 1/4 .16 liters) 15 cu.5 B M18 x 1.12) F SAE #20 (1 5/8 . (5. in. Illinois USA . Bore F 3/4” 4” G 1” 4” H 1 1/4” 4” P 1 1/2” 6” Q 2” 6” R* 2 1/2” 7” S* 3” 9” T 3/8” U 1/2” V 3/4” W 1” X 1 1/4” Y 1 1/2” Z 2” BSPP/BSPT A 3/8 . 3 *** SAE #12 3/4 SAE #12 3/4 SAE #16 1 SAE #16 1 2” Code 62 Flange 2” ISO6162 Flange 2” Code 62 Flange 2” ISO6162 Flange 63 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. (0.8 liters) 25 gal. in. Port K T C U V SAE #8 Hyd. (0.14) 6000 PSI (Code 62) Min.69 liters) 2½ gal. (114 liters) Hydraulic and Gas Port Modifications Designated by 2 Digits 1st Digit Blank Style Std.Catalog HY10-1630/US Page Ordering Information Piston Accumulators Series 5000 How to Order Series 5000 Piston Accumulators Piston accumulators and gas bottles can be specified by using the symbols in the chart below to develop a model number. (37. (75.18) C SAE #8 (3/4 . (1. 2” 2” 2” 2” 3” 3” 4” 7” 2” Description Min. (9. in. in.47 liters) 1 gal. Order fuse assembly separately.11 * For socket weld flange.M. (15.16) D SAE #12 (1 1/16 . (37. and place them in the sequence indicated by the example at the top of the chart. (0.9 liters) 7½ gal. Special (to be specified) * Safety fuse assembly not included. (0. (0. (1.25 liters) 29 cu. Port (BSPP/Metric Flange Standard) Specify Optional Ports Optional Port (Hyd.9 liters) 15 gal. 2nd Digit Blank Std. 6” Threaded both ends A. in. 4”. 3”.79 liters) 1½ gal. Nominal Bore Type of Size Construction Options Series Capacity Design Pressure Design Number Seal Compound Hyd. (9. (56.S. (28. (0.47 liters) 116 cu. R BSPP Parallel B BSPT Taper Port G Metric Y ISO 6149-1 2” 2” 2” 2” 2” 4” 4” Metric/ISO A M14 x 1.M. (1. in. in. Water Service MS28889-2 Gas Valve MS 28889-2 Gas Valve. in. See Port Modifications Table) Special Design Standard Ports Available (See Port Modifications Table if Using Other Than Standard Ports Shown Below) Bore Size 2” 3” 4” 6” 7” 9” Standard Ports Metric (BSPP) Ports Seal Compound (See Catalog for Temperature Settings) K E D H Q S Buna Nitrile (Std) Fluoroelastomer EPR Hydrogenated Nitrile Low Temp. (94.95 liters) 90 cu. mat’l standard on 7” & up Same as K with A.E. Port NPT 3/4” Gas Port Design Number 1 2 Standard Ports Metric Mounting Holes & Hyd. Water Service Fuse Port* and MS28889-2 Fuse Port* and MS28889-2. (3. (56. (28. CE marked (1 liter and above) or SEP marked (under 1 liter) 6” A SAE #5 (1/2 .6 liters) 30 gal.8 liters) 20 gal. (5.9 liters) 5 gal.E.5 D M27 x 2 E M33 x 2 F M42 x 2 G M48 x 2 Design Pressure C H Options Blank W F G M L P R Standard Gas Cap Water Service SAE Fuse Port * SAE Fuse Port *. (37. Available as special on smaller sizes Threaded both ends.19 B 1/2 .69 liters) 2½ gal.12) I SAE #10 (7/8 .79 liters) 1½ gal. in. Bore Size 2” Nominal Bore Size 2 3 4 6 7 9 2 inches 3 inches 4 inches 6 inches 7 inches 9 inches 3” T SAE Straight Thread Ports 4” P Flange Code 62 M Metric Flange per ISO 6162 Type of Construction N Threaded both ends non-ASME mat’l standard on 2”. Illinois USA .Catalog HY10-1630/US Page Notes Piston Accumulators Series 5000 64 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA Bladder . 1 Gallon & Up • Water/Chemical Service Available.Bladder Accumulators BLADDER PRODUCTS • Bottom Repairable • Top Repairable • Medium Flow • High Flow • Transfer Barrier • Gas Bottle Features: • Operating Pressures to 6600 PSI • Ten Different Capacities from 10 cu in to 15 gallons • Nine Different Configurations • Highest Quality In-House Manufactured Bladders • ASME Certification Standard. with Stainless Steel Ports • Five Bladder Compounds to Suit a Variety of Fluids & Temperatures • CE Marking Available 65 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Max. For pressures over 6600 psi. High Flow Max. absorbing hydraulic shocks. providing a proven design for many hydraulic system applications. For your convenience. see Standard and Optional Bladders. Specifications Materials • Shell – high strength alloy steel (SA372. Bladders compatible with most industrial fluids can be furnished on special orders with temperature ranges from -40°F to 250°F (-40°C to 121°C). high strength alloy steel – water & chemical service: 3000 psi. 304 stainless steel 5000 psi. low lubricity fluids • wide range of compounds for a variety of fluids Greer bladder products maintain the highest quality because of our in-house bladder molding operations.* 4 to 1 4 to 1 4 to 1 ASME Appendix 22 Rating Consult Factory 4000 PSI 6600 PSI D. specify at the time of order. Maximum Flow Rates Size (gallon) 10 cu in 1 pt & 1 qt 150 cu in 1 2½ thru 15 2½ thru 15. = Design Factor. 1) is available as standard on bladder accumulators (1 gallon & up) and ASME Appendix 22 Certification as an option. Recommended Compression Ratio (max. Rating 3000 PSI 3000 PSI 5000 PSI D. The Greer bladder product line offers the broadest line of quality products. all sizes comply with ASME material specifications. Certifications – ASME Certification (Section VIII-Div. working pressure/precharge pressure): 4 to 1. 66 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Std. For specific precharge pressures. Recommended Flow for Standard Mineral Oils GPM LPM 23 87 40 151 60 227 150 568 220 833 480 1819 600 2271 Fluids – Greer bladder accumulators are compatible with a wide variety of fluids. 5000 PSI Status Option Std. consult the factory. Bladder Accumulators Introduction Bladder Products… The Original and still the Best! The Greer bladder style accumulator is the industry's original.F. Illinois USA . and long service life. • Ports (see Options in this section) • Port Adapters (see Accumulator Accessories) • Water & Chemical Service (see Options in this section) • Gas Valves (see Options in this section) • Fuse Plugs Assemblies (see Options in this section) • Fixed Gauge Adapters (see Accumulator Accessories) Pressure Ratings – 3000 and 5000 psi bladder accumulators are rated at minimum 4 to 1 design factors as standard. Medium Flow 2½ thru 15. See page 3 for a complete certification summary. The heart of the bladder accumulator is the actual bladder. Std. cannot be disassembled under pressure • very quick response • works well with water. Available Options – a wide variety of options are available on Greer bladder accumulators including: • Bladder Compounds (see Standard and Optional Bladders in this section). Bladder accumulators provide excellent gas and fluid separation ensuring dependable performance. and still the best! For years this style of accumulator has served both the industrial and mobile hydraulic markets.F. They are suitable for storing energy under pressure. 3000 PSI 1 thru 15 gal. 1 gal. and dampening pump pulsation and flow fluctuations. & larger supplied with ASME Certification as standard) • Ports – all oil service ports.* 3 to 1 3 to 1 *Note: D.F. including: • • • • • • • 3000 & 5000 PSI Bottom Repairable 3000 & 5000 PSI Top Repairable 3000 PSI Medium Flow 3000 PSI High Flow 3000 PSI Transfer Barrier 3000 & 5000 PSI Gas Bottles A Wide Array of Options and Accessories Why Use Bladder Accumulators? • improves system efficiency • supplements pump flow • supplies power in emergency • compensates for leakage • absorbs hydraulic shocks • highly contaminant tolerant • universal application • high/low temperature tolerance • safety. and all Greer bladders are engineered and manufactured in our own facility and subjected to our own high quality inspection standards. Size 10 thru 150 in3 3000 PSI 1 thru 15 gal.Catalog HY10-1630/US Specifications Bladder accumulators provide a means of regulating the performance of a hydraulic system. 17-4 PH stainless steel • Poppet & Spring – 304 stainless steel • Gas Valve Cartridge – steel • Gas Valve Protector – steel • Gas Valve Stem – steel • Bladders – various polymers. ASME Cert. 4000 and 6600 psi (ASME Appendix 22) bladder accumulators are available as an option at minimum 3 to 1 design factors. Precharge – Units are shipped with a nominal nitrogen precharge as standard. the latest in accumulator sizing technology is available with the inPHorm Accumulator Sizing and Selection Software. The standard accumulator may be used with petroleum-based industrial or water-based flame resistant fluids. maximum efficiency. Chemical and water service port assemblies are made from stainless steel for maximum corrosion resistance. See page 75 for details. Also. and curing processes. the gas valve vents if unscrewed. are fitted as standard with two-piece bladder stems with replaceable gas valve cartridge for ease of serviceability. the heart and soul of a bladder accumulator. It is widely accepted that Greer bladders are the highest quality bladders in the industry. not available on flange ports. One-gallon and larger 3000 psi units are equipped with a cored gas valve cartridge (ISO-4570-8V1) for ease of maintenance. and High-Flow ports are available. Bleed ports are included as standard on sizes 1 gallon and larger. Spec MS28889-2). are manufactured in-house to control the material blending. the twopiece stem will accept high pressure military gas valves and permanent mount gauge adapters. molding. One gallon and larger supplied with ASME Certification as standard. 7 Gas Valve All accumulators are fitted with a gas valve for ease of gas precharging. Bladders are offered in six different standard compounds to suit a wide variety of fluids and operating temperatures.Catalog HY10-1630/UStontent Design Features and Benefits 7 Bladder Accumulators Introduction 6 1 2 7 3 4 5 1 Shell Bladder accumulator shells are made from chrome-molybdenum alloy steel (SA372) with forged ends. 2 Bladder Greer bladders. 5000 psi units are equipped with a high pressure cored gas valve cartridge (ISO-4570-8V1) with an option of a poppet-type (military) gas valve cartridge (Mil. For safety. critical seam assembly. NPTF. All sizes comply with ASME material and design specifications. 6 Top Repairable The top repairable design permits easy checking and maintenance of the bladder without removing the accumulator from the service line. 4 Port Assemblies Standard oil service ports are made from high-strength alloy steel for maximum durability. saving time and money. sizes 1 gallon and larger. Illinois USA . 3 Bladder Stems All bladder accumulators. Special compounds are available for unusual or severe applications. 5 Fluid Ports SAE straight thread. 67 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. SAE Code 61 and SAE Code 62 4-bolt split flange. 50 (64) 2.) 50 (23) 120 (55) 200 (91) 335 (152) 485 (220) 2) Note: Available with 6600 PSI (455 Bar) Appendix 22 Approval.6) 8 (3.63 (245) 9.75 (197) 6.79) 556 (9.18) SAE #24 SAE #6 (1-7/8 .00 (1371) 72.03 (26) 1.88 (99) 3. inch (mm) A 11.5 (1.88 (73) 2.50 (394) 27.00 (76) 3.9) 11 (41.50 (64) Hydraulic Ports H I (Thread) (Thread) SAE #20 SAE #6 (1-5/8 .88 (73) 2.37 (60) 3.38 (543) 33.12) (9/16 .00 (76) 3.14 (181) 9.46) 5 (18.08 (53) 3.50 (64) 2.88 (1978) B 1.25 (32) Hydraulic Ports H I (Thread) (Thread) SAE#8 N/A (3/4 .12) (9/16 .00 (76) 3. (0.88 (99) 3.88 (1520) 77.00 (51) 2.25 (32) 1.00 (1830) G 0.16) SAE #12 N/A (1-1/16 .08) 156 (2.12) SAE #12 N/A (1-1/16 .06 (230) 9.12) (9/16 . Sizes range from 10 cu in to 15 gallons.13 (54) 2.94 (24) 0.18) Weight lbs.75 (273) 11.25 (32) 1.88 (73) 2.12) (9/16 .8) Gas Volume cu in (Liters) 12 (0.25 (32) 1.50 (38) 2.Catalog HY10-1630/US Bottom Repairable The simplicity and cost effectiveness of the bottom repairable design has made it the “Industry Standard” bladder accumulator.00 (432) 21.25 (438) 22.12 (409) 28.6) 15 (56.12) (9/16 .79) 2. 5000 PSI (345 Bar) 2 Models Oil Service Water Service BA01B5T01A1 BA01B5T01WA1 BA02B5T01A1 BA02B5T01WA1 BA05B5T01A1 BA05B5T01WA1 BA10B5T01A1 BA10B5T01WA1 BA15B5T01A1 BA15B5T01WA1 Nominal Size Gallon (Liters) 1 (3. (Kg.11) 1124 (18.79) 556 (9.25 (32) 1.9) 10 (37.56 (497) 17.38 (1788) G 1.12) SAE #20 SAE #6 (1-5/8 .50 (38) 1.54) Dimensions.42) 2097 (34.31 (33) 1.18) SAE #24 SAE #6 (1-7/8 .63 (245) 9.25 (83) 3.62 (41) 2.75 (171) 9.80 (884) 55.62 (92) 3.06 (230) D 1.21) 31 (0.00 (76) 3.00 (76) 3.62 (41) 1.62 (92) 3.1) 34 (15) 80 (36) 120 (55) 220 (100) 240 (109) 305 (139) 1) Note: 1 thru 15 gallon sizes available with 4000 PSI (275 Bar) Appendix 22 Approval.12) (9/16 .33) 3267 (53.5 (9.79) 2.06 (230) 9.12 (282) 19.80 (1951) B 3.50 (114) 6.42) 2097 (34.18) Weight lbs.18) SAE #24 SAE #6 (1-7/8 .54) Dimensions.47) 1 Qt.94 (24) 0. Illinois USA .46) 5 (18.38 (1382) 59.00 (76) 3.06 (230) 9. inch (mm) A 17.50 (700) 48.12) (9/16 .88 (73) 2.62 (92) C 2.50 (114) 4.63 (245) 9.95) 150 cu in (2.8) Gas Volume cu in (Liters) 231 (3.88 (73) F 7.44 (37) 2.18) SAE #24 SAE #6 (1-7/8 .51) 66 (1.94 (24) 0.12) SAE #16 N/A (1-5/16 .5) 1 (3.18) SAE #24 SAE #6 (1-7/8 .00 (76) 3.39 (35) 1.) 3.40 (86) 4.94 (24) 1.12) (9/16 .25 (57) 3. Bladder Accumulators Models.00 (76) E N/A 2.50 (64) 2.56) 231 (3.18 (284) 10.36) 2400 (39.18) SAE #24 SAE #6 (1-7/8 .50 (394) 11.44 (291) 16.50 (1231) 54.12) (9/16 .12) (9/16 .25 (57) 3.36) 3267 (53.18) SAE #24 SAE #6 (1-7/8 .62 (92) 3.50 (89) 3.63 (194) 15.11) 1124 (18.5 (9.12) (9/16 . (Kg.62 (92) 3.18) SAE #24 SAE #6 (1-7/8 .18) SAE #24 SAE #6 (1-7/8 .16) 1 Pt.88 (1242) 70.88 (73) F 11.38 (848) 54.6) 10 (4.36 (720) 48. 68 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.88 (73) 2.5) 20 (9.36 (289) 15.88 (99) 3.87 (174) 7.55 (573) 34.00 (76) E 0.30 (1405) 76.00 (51) 2.88 (99) C 7.9) 10 (37.06 (230) 9.63 (245) D 2.88 (73) 2.94 (24) 1. Capacities and Dimensions Introduction C G (Hex) A F I B E FLAT D H 3000 PSI (207 Bar) 1 Models Oil Service Water Service BAC10B3T01A1 BAC10B3T01WA1 BA001B3T01A1 BA001B3T01WA1 BA002B3T01A1 BA002B3T01WA1 BA005B3T01A1 BA005B3T01WA1 BA01B3T01A1 BA01B3T01WA1 BA02B3T01A1 BA02B3T01WA1 BA05B3T01A1 BA05B3T01WA1 BA10B3T01A1 BA10B3T01WA1 BA11B3T01A1 BA11B3T01WA1 BA15B3T01A1 BA15B3T01WA1 Nominal Size Gallon (Liters) 10 cu in (0. (0.25 (32) 1.9) 15 (56.56 (40) 2.88 (73) 2. Catalog HY10-1630/UStontent Top Repairable The Top Repairable Accumulator permits easy checking and maintenance of the bladder without removing the accumulator from the service line.8) 11 (41.12) (9/16 .13) 3253 (53.18) SAE #24 SAE #6 (1-7/8 .75 (1822) G 1.87) 1110 (18.12) (9/16 . Illinois USA .68 (551) 33.00 (76) E 2.88 (99) 3.12) (9/16 .18) SAE #24 SAE #6 (1-7/8 . (Kg.18) SAE #24 SAE #6 (1-7/8 .18) SAE #24 SAE #6 (1-7/8 .25 (1353) 59.88 (73) 2.88 (99) C 9.06 (230) 9.00 (76) 3.18) SAE #24 SAE #6 (1-7/8 .19) 2083 (34.5 (9.46) 5 (18.13 (1223) 53.62 (92) C 9.00 (1499) 77.00 (76) E 2.7) Gas Volume cu in (Liters) 541 (8.00 (76) 3.12) (9/16 . Capacities and Dimensions Introduction C G (Hex) F A B I D H E FLAT 3000 PSI (207 Bar) 1 Models Oil Service Water Service BA02T3T01A1 BA02T3T01WA1 BA05T3T01A1 BA05T3T01WA1 BA10T3T01A1 BA10T3T01WA1 BA11T3T01A1 BA11T3T01WA1 BA15T3T01A1 BA15T3T01WA1 Nominal Size Gallon (Liters) 2.5 (9.12) (9/16 .50 (521) 32.88 (73) 2.9) 10 (37.1) 3253 (53.12) (9/16 .88 (73) 2.25 (32) 1.00 (76) 3.12) (9/16 .18) SAE #24 SAE #6 (1-7/8 .62 (92) 3.12) (9/16 .19) 2083 (34.8) Gas Volume cu in (Liters) 541 (8.88 (73) F 15.6) 15 (56.25 (32) 1.42 (1382) 75.88 (73) 2.25 (32) Hydraulic Ports H I (Thread) (Thread) SAE #24 SAE #6 (1-7/8 . Bladder Accumulators Models.92 (862) 54.62 (92) 3.12) (9/16 .88 (73) F 15.31) Dimensions.63 (245) 9.13) 2386 (39.88 (73) 2.06 (230) 9.63 (702) 48.8) 15 (56.06 (230) D 3.13 (715) 48.45) 5 (18.75 (832) 53.25 (32) 1.25 (32) 1.38 (391) 27.00 (76) 3.88 (99) 3.18) SAE #24 SAE #6 (1-7/8 .63 (245) 9. Sizes range from 2-1/2 to 15 gallons.25 (32) 1.63 (1235) 70.00 (76) 3.9) 10 (37.62 (92) 3.13 (1781) G 1.31) Dimensions.87) 1110 (18.25 (32) Hydraulic Ports H I (Thread) (Thread) SAE #24 SAE #6 (1-7/8 .88 (73) 2.38 (1965) B 3.18) Weight lbs.06 (230) 9.) 80 (36) 120 (55) 220 100 240 (109) 305 (139) 1) Note: Available with 4000 PSI (275 Bar) Appendix 22 5000 PSI (345 Bar) 2 Models Oil Service Water Service BA02T5T01A1 BA02T5T01WA1 BA05T5T01A1 BA05T5T01WA1 BA10T5T01A1 BA10T5T01WA1 BA15T5T01A1 BA15T5T01WA1 Nominal Size Gallon (Liters) 2.63 (245) D 3. inch (mm) A 20.63 (245) 9.88 (73) 2.62 (92) 3.88 (1369) 71. inch (mm) A 21.00 (76) 3.92 (1928) B 3.25 (32) 1.88 (403) 23.88 (99) 3.00 (76) 3.25 (32) 1.18) Weight lbs.06 (230) 9. (Kg.) 120 (55) 220 (100) 335 (152) 485 (220) 2) Note: Available with 6600 PSI (455 Bar) Appendix 22 69 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. saving time and money. 5 (9.50 (699) 48.88 (149) C 9.88 (149) 5.06 (230) 9. 70 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.25 4.88 (149) 5.54) Dimensions.87 (581) 35.Catalog HY10-1630/US Medium Flow For systems requiring a faster “dumping” rate.85 (98) 3.25 (32) 1.85 (98) 3.06 (230) D 3.) 80 (36) 120 (55) 220 (100) 240 (109) 305 (139) NOTE: Medium flow bladder accumulators not available with Appendix 22 option.06 (230) 9.63 (92) E 3.63 (92) 3. the Medium Flow accumulator incorporates a larger port assembly capable of flows up to 480 GPM (1819 LPM).11) 1124 (18.33) 3267 (53.46) 5 (18.85 (98) F 15.88 (149) 5. Sizes range from 2-1/2 to 15 gallons.63 (92) 3.42) 2097 (34.37 (1559) 79.25 (32) 1.12 (892) 55.9) 10 (37.12 (2010) B 5. in (mm) A 22. Male NPT BA02B3C01A1 BA05B3C01A1 BA10B3C01A1 BA11B3C01A1 BA15B3C01A1 Nom. Groove for 2-232 O-ring 2.00 (1219) 53.C.5 (1816) G 1.6) 15 (56. (L) 2.85 (98) 3.63 (92) 3. Bladder Accumulators Models. Thd. Capacities and Dimensions Introduction C G F A E B I H D 3000 PSI (207 Bar) Models Male Str.75 (1365) 71.870 ∅6.870 ∅1. Size Gal.9) 11 (41.25 (32) 1.300 (4) Note: Accumulator assembly does not include flange.62 (1413) 61.63 (92) 3.000 4. Illinois USA .887 B.06 (230) 9.36) 2400 (39.25 (32) H Hydraulic Port M95x2 M95x2 M95x2 M95x2 M95x2 Port I (Thread) SAE #6 (9/16-18) SAE #6 (9/16-18) SAE #6 (9/16-18) SAE #6 (9/16-18) SAE #6 (9/16-18) Weight lbs (Kg.88 (149) 5.06 (230) 9. cu in (L) 556 (9.8) Gas Vol.25 (387) 27.25 (32) 1. Optional Flange Port Details ∅3.85 (98) 3. 85 (98) 3.46) 5 (18.33) 3267 (53. 4 NPTF 4-1/4"-8 Str.25 (32) 1. (L) 2.75 .88 (581) 35.62 (1413) 61. Thd.62 (143) 5.62 (143) 5.85 (98) 3.8) Gas Vol. the High Flow accumulator incorporates a large port assembly capable of flows up to 600 GPM (2270 LPM). cu in (L) 556 (9.00 (102) 4. Size Gal.50 (1765) G 1.00 (1219) 53. Capacities and Dimensions Introduction C G F A B E I H D 3000 PSI (207 Bar) Models1 Male Str.62 (143) 5.85 (98) F 15.85 (98) 3.25 (32) 1.) 90 (41) 130 (59) 230 (105) 250 (114) 315 (143) NOTE: High flow bladder accumulators not available with Appendix 22 option.00 (102) 4.25 (32) 1. Optional Flange Port For Model “A” Hydraulic Port only 3. 4 NPTF 4-1/4"-8 Str.5 (9.38 (1559) 79.62 (143) 5.54) Dimensions.06 (230) D 4. Illinois USA 3.06 (230) 9.6) 15 (56. Bladder Accumulators Models.25 (32) 1. Thd.62 (143) C 9. 2. Note: Accumulator assembly does not include flange.12 (892) 55.00 (102) 4.11) 1124 (18.00" Dia. 4 NPTF Port I (Thread) SAE #6 (9/16-18) SAE #6 (9/16-18) SAE #6 (9/16-18) SAE #6 (9/16-18) SAE #6 (9/16-18) Weight lbs. in (mm) A 22.42) 2097 (34.50 (699) 48.06 (230) 9.9) 10 (37.75 1/2-20 UNF-2B x 1" Deep 2.06 (230) 9. 71 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.00 (102) 4.75 (1365) 69.19 3.06 (230) 9. 4 NPTF 4-1/4"-8 Str.9) 11 (41. 4 NPTF 4-1/4"-8 Str.25 (32) Hyd. (Kg. Thd. Thd.62 (2022) B 5. Port H 4-1/4"-8 Str. Thd.5 Typ.85 (98) 3.25 (387) 27. Thd. Sizes range from 2-1/2 to 15 gallons.36) 2400 (39.Catalog HY10-1630/UStontent High Flow For systems requiring a fast “dumping” rate.00 (102) E 3. Male NPT BA02B3A01A1 BA02B3H01A1 BA05B3A01A1 BA05B3H01A1 BA10B3A01A1 BA10B3H01A1 BA11B3A01A1 BA11B3H01A1 BA15B3A01A1 BA15B3H01A1 Nom. 12) SAE #12 (1-1/16 .8) 15 (56.00 (51) 2.45) 5 (18. Illinois USA .9) 10 (37.88 (73) 2. Capacities and Dimensions Introduction J C G Hex F A B E Flat H D I 3000 PSI (207 Bar)1 Models Oil Service Water Service BT02B3TT01A1 BT02B3TT01WA1 BT05B3TT01A1 BT05B3TT01WA1 BT10B3TT01A1 BT10B3TT01WA1 BT11B3TT01A1 BT11B3TT01WA1 BT15B3TT01A1 BT15B3TT01WA1 Nominal Gas Size Volume Gallon cu in A (Liters) (Liters) 2.18) SAE #6 (9/16 .12) SAE #24 (1-7/8 .00 (76) E 2.62 (92) C 9.88 (73) 2.12) SAE #24 (1-7/8 .00 (76) 3.36) 3267 (53. in (mm) A 22.12 (1375) 72.00 (51) Hydraulic/Gas Ports H (Thread) SAE #24 (1-7/8 .00 (76) 3.12) SAE #12 (1-1/16 . (Kg.12) I (Thread) SAE #6 (9/16 .12) SAE #12 (1-1/16 .18) SAE #6 (9/16 .00 (1829) G 2.00 (76) 3.62 (92) 3.62 (92) 3.Catalog HY10-1630/US Transfer Barrier The Transfer Barrier accumulator provides positive separation between two different medias or can be used with gas bottles.63 (245) 9.88 (708) 48.00 (51) 2.12) Weight lbs.62 (56.7) (53.88 (73) 2.12) SAE #24 (1-7/8 .88 (73) F 15.00 (37.12) SAE #24 (1-7/8 .38 (1788) G 2.50 (1231) 54.00 (76) 3.06 (230) 9.33) (1518) 15 3267 77.8) (34.55 (573) 34.54) (1972) Dimensions.30 (1405) 76.5 (9.) 120 (55) 200 (91) 335 (152) 485 (220) 2) Note: Available with 6600 PSI (455 Bar) Appendix 22 72 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.75 (41.00 (51) 2.12) Weight lbs.80 (884) 55.9) (18.12) SAE #12 (1-1/16 .12) I (Thread) SAE #6 (9/16 .88 (73) 2.18) J (Thread) SAE #12 (1-1/16 .42) (851) 10 2097 54.00 (51) 2.12) SAE #12 (1-1/16 .6) (39.06 (230) 9.00 (76) 3.00 (51) 2.12) SAE #24 (1-7/8 .54) Dimensions.50 (18.63 (245) 9.88 (73) 2.36) (1372) 11 2400 59.00 (76) 3.25 (9.45) (9.00 (76) 3.7) Gas Volume cu in (Liters) 556 (9.12) SAE #24 (1-7/8 .12 (409) 28.12) SAE #12 (1-1/16 .18) SAE #6 (9/16 .06 (230) 9.00 (51) 2.00 (51) 2.62 (92) 3.80 (1951) B 3.5 556 21. (Kg.11) (540) 5 1124 33.00 (51) Hydraulic/Gas Ports H (Thread) SAE #24 (1-7/8 .) 80 (36) 120 (55) 220 (100) 240 (109) 305 (139) 1) Note: Available with 4000 PSI (275 Bar) Appendix 22 5000 PSI (345 Bar)2 Models Oil Service Water Service BT02B5TT01A1 BT02B5TT01WA1 BT05B5TT01A1 BT05B5TT01WA1 BT10B5TT01A1 BT10B5TT01WA1 BT15B5TT01A1 BT15B5TT01WA1 Nominal Size Gallon (Liters) 2.62 (92) 3.88 (73) 2.63 (245) 9.06 (230) D 3.36 (720) 48.88 (73) 2.18) J (Thread) SAE #12 (1-1/16 .88 (73) F 16.11) 1124 (18.63 (245) D 3.18) SAE #6 (9/16 .62 (397) 27.18) SAE #6 (9/16 .18) SAE #6 (9/16 .06 (230) 9.62 (92) 3. Sizes range from 2-1/2 to 15 gallons.62 (92) 3.62 (92) 3. Bladder Accumulators Models.00 (76) E 2.12) SAE #12 (1-1/16 .42) 2097 (34.62 (92) C 9.12) SAE #24 (1-7/8 .18) SAE #6 (9/16 . in (mm) B 3.88 (1242) 70. 80 (1951) B 3.25 (438) 22.9) 10 (37.25 (57) 3.12) SAE #24 (1-7/8 .6) 15 (56.25 (32) 1.88 (99) 3.00 (76) 3.12) SAE #24 (1-7/8 . a smaller accumulator may be used by connecting it to an auxiliary gas bottle(s) that may be located in some nearby spot where space is available.00 (76) 3.00 (76) 3.00 (1829) G 1.5 (9.62 (92) 3.8) Dimensions.25 (32) 1.36 (289) 15.88 (73) 2.25 (83) 3.12) (9/16 .63 (245) 9.38 (1788) G 1.00 (1372) 59.63 (245) 9.00 (76) 3.62 (397) 27.9) 11 (41.88 (73) 2.25 (540) 33.88 (73) 2.88 (99) 3.75 (1518) 77.88 (73) F 11.38 (1102) 54.00 (432) 21.12) SAE #24 (1-7/8 .5 (9.00 (76) E 2.25 (32) 1.18) SAE #24 SAE #6 (1-7/8 .44 (291) 16.50 (851) 54.88 (99) C 7.46) 5 (18.12) (9/16 .88 (73) 2.06 (230) D 2.18) Weight lbs. Bladder Accumulators Models.88 (1242) 70.18) SAE #6 (9/16 . Illinois USA .25 (32) 1.88 (99) 3.) 34 (15) 80 (36) 120 (55) 220 (100) 240 (109) 305 (139) 1) Note: Available with 4000 PSI (275 Bar) Appendix 22 5000 PSI (345 Bar)2 Nominal Size Gallon (Liters) 1 (3.06 (230) 9.12) SAE #24 (1-7/8 .12) (9/16 . Capacities and Dimensions Introduction G C F A B H 3000 PSI (207 Bar) 1 D E (Flat) I Ports Models BG01B3T01A1 BG02B3T01A1 BG05B3T01A1 BG10B3T01A1 BG11B3T01A1 BG15B3T01A1 Nominal Size Gallon (Liters) 1 (3.80 (884) 55.25 (32) 1.00 (76) 3.12 (409) 28.88 (73) 2.12) I (Thread) SAE #6 (9/16 .88 (73) F 11.46) 5 (18.00 (76) E N/A 2.30 (1405) 76.25 (32) H (Thread) SAE #20 (1-5/8 .) 50 (23) 120 (55) 200 (91) 335 (152) 485 (220) Models BG01B5T1A1 BG02B5T1A1 BG05B5T1A1 BG10B5T1A1 BG15B5T1A1 2) Note: Available with 6600 PSI (455 Bar) Appendix 22 73 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.) Sizes range from 1 to 15 gallons.18) SAE #24 SAE #6 (1-7/8 .06 (230) 9.62 (1972) B 3.88 (708) 43.36 (720) 48. (Kg.50 (89) 3.12) SAE #24 (1-7/8 .Catalog HY10-1630/UStontent Gas Bottles Where space does not permit the installation of the required accumulator.00 (76) 3.00 (76) 3.18) SAE #24 SAE #6 (1-7/8 . inch (mm) A 17.18) SAE #6 (9/16 .44 (37) 2.18) SAE #6 (9/16 .06 (230) 9.12) (9/16 .79) 2.55 (573) 34.18) SAE #6 (9/16 .79) 2.06 (230) 9.37 (60) 3.18) Weight lbs.14 (181) 9.62 (92) 3.75 (171) 9.12) (9/16 .50 (64) 2.50 (64) 2.63 (245) D 2.12 (1375) 72.88 (73) 2. inch (mm) A 17.50 (64) 2.62 (92) C 6.88 (73) 2. (See Large Gas Bottles for additional offerings and page 104 for sizing information.8) Dimensions.18) SAE #6 (9/16 .63 (245) 9.62 (92) 3.18) SAE #24 SAE #6 (1-7/8 . (Kg.13 (54) 2.9) 10 (37.50 (64) Ports H I (Thread) (Thread) SAE #20 SAE #6 (1-5/8 .9) 15 (56.62 (92) 3. MS28889-2). ISO-4570-8V1) as standard.Catalog HY10-1630/US Bladders. Illinois USA . The Skotchkote offers added protection against more corrosive fluids. Standard Gas Valve Military Gas Valve #5 SAE THREAD 1/2–20 UNF-2A 1/2–20 UNF-2A L07421000* (3000 PSI) L07688000* (4000 PSI) L07440000* 74 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Recommended Operating Temperature Range -20°F to 200°F -29°C to 93°C -40°F to 225°F -40°C to 107°C -40°F to 200°F -40°C to 93°C -40°F to 200°F -40°C to 93°C -10°F to 250°F -23°C to 121°C Maximum Temperature with Reduced Life 225°F 107°C 250°F 121°C 300°F 149°C 300°F 149°C 400°F 204°C Seal Code 01 04 06 08 28 Polymer Buna-Nitrile Hydrin (Lo-Temp. 1 gal. & up. 5000 PSI units are equipped with a high pressure cored gas valve cartridge (ISO-4570-8V1) with an option of a heavy duty (military) poppet-type gas valve cartridge (Mil. Gas Valves Standard and Optional Bladders Bladder Accumulators Options Introduction A variety of bladders are offered to suit a wide range of fluids and operating temperatures. Water Service. Temperature ranges may vary depending upon the fluid used in the hydraulic system. Spec. and the types of fluids that are generally compatible. 3000 PSI rated models are offered with a cored gas valve cartridge (cartridge type. Water & Chemical Service Options (W) Bladder accumulators are available with a water and chemical resistance option. Gas Valves Two types of gas valves are available on bladder accumulators. their recommended operating temperature ranges. The (W) designation includes an internally Skotchkoted shell and stainless steel or electroless nickel plated port assembly.) Butyl Ethylene Propylene Fluorocarbon Elastomer General Application & Compatibility* Standard Compound – Compatible with most mineral oil-based fluids Compatible with most mineral oil-based fluids with enhanced low temperature performance Compatible with most phosphate ester fluids and some synthetic fluids Compatible with some synthetic fluids and water Compatible with most mineral oil-based fluids at higher temperatures and some exotic fluids *Note: Consult your local distributor or the factory for fluid compatibility information. The following table lists the optional bladders available. 9 F A (4 places) x G Min.250 2.438 3.062 ISO 6162 Flange Dimensions (mm) A B C F G M10 30.7 32 25. 1 gal. The flange halves are not supplied with the accumulator.062 2 1. 1 qt. Thread Code T SAE #8 SAE #12 SAE #16 SAE #20 SAE #24 Optional Ports SAE 4-Bolt Undersize Split Flange* NPTF NPTF BSPP Code F Code U Code X Code R 3000 PSI (207 Bar) Models – 3/4" Male – – – 3/4" – G 3/4" – 1" – G 1" 1-1/4".5 79.625 1-1/4 1.Catalog HY10-1630/UStontent Ports.688 3.13 1.4 M12 42. For a complete listing. Depth B Note: The dimensions shown on this chart are for the mating manifold.375 ISO 6162 Flange Dimensions (mm) A B C F G M16 31.7 32 25.125 1-1/2 1. Code 62 2" – *Split flanges not supplied. 150 cu in 1 gal. 2½ to 15 gal.4 38 34.) A B C F G 7/16 .. Code 62 1-1/4" – SAE #24 1-1/2". Standard Port SAE Str. Illinois USA Bladder .4 M16 36.000 5/8 . Code 61 1-1/4" – G 1-1/4" 2". Port Adapters A wide variety of port adapters are offered to convert Parker’s standard SAE port offerings to NPTF or smaller SAE port sizes.) A B C F G 1/2 .8 66.5 M 27x2 M 33x2 M 42x2 M 48x2 M 42x2 M 48x2 5000 PSI (345 Bar) Models SAE #20 1-1/4". and Transfer Barrier accumulators (for high flow ports. Code 61 2" 1-1/4" G 2" G 1-1/4" G 2" ISO 6149-1 Code Y M 8x1.2 58. SAE 4-Bolt Flange Port Dimensions Standard Pressure – Code 61 (ISO 6162) – 3000 PSI (207 Bar) Flange Size 1-1/4" 2" SAE Flange Dimensions (in.13 1. 75 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Port Adapters Standard and Optional Fluid Ports The following standard and optional fluid ports are offered on all Bottom Repairable. 2½ to 15 gal.11 1.8 51 26.9 C High Pressure – Code 62 (ISO 6162) – 6000 PSI (410 Bar) Flange Size 1-1/4" 1-1/2" SAE Flange Dimensions (in. see High Flow).4 1. Bladder Accumulators Options Introduction Sizes 10 cu in 1 pt. see Accumulator Accessories. See How to Order at the end of this section for complete ordering instructions.000 1/2 .312 1-1/2 1. Top Repairable. Flange end for SAE J518 Code 61/62 NOTE: 4-bolt split flange halves (not included).9 77.188 2. Illinois USA . for an assembly with a 2000 PSI setting.Catalog HY10-1630/US Safety Fuse.. consult your local distributor. The rupture disks are calibrated to rupture at a pre-determined pressure. Bladder Accumulators Options and Accessories Introduction Fuse 1. i. Special Safety Fuse Options Safety Fuses are used as a safety device on accumulators and gas bottles to prevent over-pressurization of gas due to external heat or hydraulic pressure (set at 140% of maximum system pressure to avoid rupture disk fatigue and premature failure).25 #8 SAE Straight Port Th’d 0. or the factory with your specific requirements. See “Accumulator Accessories”.70 0. Greer representative. Special Options If your application requires a bladder accumulator or special option that falls outside of our broad offering. Safety fuses are available on most sizes of piston and bladder accumulators and gas bottles.55 #8 SAE 3/4-16 UNF-2A 1. Fuse Adapter Mounting.77 #5 SAE Straight Port Th’d 1.e.48 #5 SAE Straight Port Th’d 1) Assembly includes housing and rupture disk. xxxx = pressure setting in 100 psi increments. charging and gauging accessories. order P/N 0864712000.95 3.44 Description Safety Fuse Assembly1 Replacement Rupture Disks Fuse Adapter Part Number 086471xxxx 756003xxxx 1468970002 0. The safety fuse assembly and/or fuse adapter must be ordered separately. from simple modifications to standard units to complete designs from scratch. Some example of our past special designs include: • • • • • Special and Stainless Steel Materials Special Bladder Compounds Suction Stabilizer Pulsation Dampener Special Certifications Consult our experts with your next bladder accumulator requirement! 76 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Safety fuses can be installed on 1 gallon & larger accumulators by using the “Fuse Adapter” as shown to the right. We have the manufacturing and engineering expertise to design and build bladder accumulators to your exacting requirements. Charging & Gauging Accessories Greer offers a wide variety of mounting. 1 Pt.Catalog HY10-1630/UStontent Bladder Kits Bladder Accumulators Replacement Introduction Kits A full range of genuine Greer replacement bladder kits are available to bring your accumulator back to original condition should replacement become necessary.000 PSI Bottom Repairable Bladder Kits (2" Valve Stem . Parker Parker Parker Parker 702900 0850693C10 702914 0850693001 702928 0850693002 702942 0850693006 702956 0850693010 702970 0850693025 702984 0850693050 702998 0850693100 703012 0850693110 703026 0850693150 703340 0850693250 703346 0850693400 8706135010 8706135010 704060 0850695010 706000 0861905025 706010 0861905050 706020 0861905100 706030 0861905150 0850695025 0850695050 0850695100 0850695150 702902 0856663C10 702916 0856663001 702930 0856663002 702944 0856663006 702958 0856663010 702972 0856663025 702986 0856663050 703000 0856663100 703014 0856663110 703028 0856663150 704008 0856663250 704014 0856663400 8706175010 8706175010 704062 0856665010 706002 0861945025 706012 0861945050 706022 0861945100 706032 0861945150 0856665025 0856665050 0856665100 0856665150 702903 0850703C10 702917 0850703001 702931 0850703002 702945 0850703006 702959 0850703010 702973 0850703025 702987 0850703050 703001 0850703100 703015 0850703110 703029 0850703150 704009 0850703250 704015 0850703400 8706145010 8706145010 704063 080705010 706003 0861915025 706013 0861915050 706023 0861915100 706033 0861915150 0850705025 0850705050 0850705100 0850705150 702904 0851053C10 702918 0851053001 702932 0851053002 702946 0851053006 702960 0851053010 702974 0851053025 702988 0851053050 703002 0851053100 703016 0851053110 703030 0851053150 703341 0851053250 703347 0851053400 8706145010 8706145010 704064 0851055010 706004 0861935025 706014 0861935050 706024 0861935100 706034 0861935150 0851055025 0851055050 0851055100 0851055150 702906 0851043C10 702920 0851043001 702934 0851043002 702948 0851043006 702962 0851043010 702976 0851043025 702990 0851043050 703004 0851043100 703018 0851043110 703032 0851043150 703342 0851043250 703348 0851043400 8706155010 8706155010 704066 0851045010 706006 0861925025 706016 0861925050 706026 0861925100 706036 0861925150 0851045025 0851045050 0851045100 0851045150 5. NOTE: Part numbers shaded in gray will be phased out.000 PSI Bottom Repairable Bladder Kits (7/8" Valve Stem . 10 Gal.New Style) 5. 5 Gal. 40 Gal. 1 Qt. 15 Gal. 25 Gal. 10 Gal. 7/8" ∅ Stem 1 Gal. Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker 2 1/2 Gal. All bladder kits include port o-ring. 1 Gal. Bladder & Seal Compound 3. In. Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker Greer Parker 1 Gal. In. Illinois USA Bladder Size Brand Group 01 Nitrile (NBR) Group 04 Hydrin Group 06 Butyl Group 08 EPR Group 28 Fluorocarbon . 15 Gal. 11 Gal. 10 Gal. 1" ∅ Stem 2 1/2 Gal.000 PSI Standard Bladder Kits (Top & Bottom Repairable) 10 Cu. 150 Cu. 15 Gal. backup seals and gas valves with secondary seals. 2 1/2 Gal. 5 Gal.Old Style) 77 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 5 Gal. S. design with “U” stamp. Port1 Bladder/Seal Design Compound Modification Design Code BA Series BA BG BT Accumulator Gas Bottle Transfer Barrier 001 B 3 T 01 –A 1 Hydraulic Port T Available 3000 5000 PSI PSI • • • • • • • • • • U • • • • • SAE Straight Thread O-Ring (Standard) 10 Cl SAE #8 1 Pint & 1 Quart SAE #12 150 Cl SAE #16 1 Gallon SAE #20 2½ Gallon thru 15 Gallon SAE #24 NPT Pipe (No Cost Option) 10 Cl 3/4” NPT Male 1 Pint & 1 Quart 3/4” NPTF 150 Cl 1” NPTF 1 Gallon 1 1/4” NPTF 2½ Gallon thru 15 Gallon 2” NPTF SAE 4-Bolt Split Flange (No Cost Option) 10 Cl thru 150 Cl (3K) N/A 1 Gallon (3K) 1 1/4” Code 61 (3000 PSI) 1 Gallon (5K) 1 1/4" Code 62 (6000 PSI) 2½ Gal. (3K) 2” Code 61 (3000 PSI) 2½ Gal. available with “U” stamp.600 PSI Special X R Y * 1 Gal.S. (4K) 1 1/2” Code 62 (6000 PSI) 2½ Gal.5 1 Pint & 1 Quart M27 x 2 150 Cl M33 x 2 1 Gallon M42 x 2 2½ Gallon thru 15 Gallon M48 x 2 Metric 10 Cl M18 x 1.M. (5K) 1 1/2” Code 62 (6000 PSI) High Flow 4” NPT Male (Extra Cost Option) Available on 2½ Gallon thru 15 Gallon Sizes only (3000 PSI) High Flow 4¼-8 UN-2 Straight Thread Male (Extra Cost Option) Available on 2½ Gallon thru 15 Gallon Sizes only (3000 PSI) Medium Flow M95x2 Straight Thread Male (Extra Cost Option) Available on 2½ Gallon thru 15 Gallon Sizes only (3000 PSI) NPT Pipe Undersized (No Cost Option) 2½ Gallon thru 15 Gallon Sizes only (3000 PSI) 1-1/4” NPT BSPP 10 Cl N/A 1 Pint & 1 Quart 3/4-14 150 Cl 1-11 1 Gallon 1 1/4-11 2½ Gallon thru 15 Gallon 2-11 ISO 6149-1 10 Cl M18 x 1. Select only those symbols that represent the features desired.) Hydrin (Optional) Butyl (Optional) EPR (Optional) Fluoroelastomer (Optional) C Working Pressure 3 4 5 6 Y 3.. – A.M. it must be specified at time of order. 1 Pt. G S 78 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. thru 15 Gal. and place them in the sequence indicated by the example at the top of the chart. and 150 C. thru 15 Gal.000 PSI 6.5 1 Pint & 1 Quart M27 x 2 150 Cl M33 x 2 1 Gallon M42 x 2 2½ Gallon thru 15 Gallon M48 x 2 Special 1 * Design Code Standard Number given Size C10 001 002 005 01 02 05 10 11 15 10 Cl 1 Pint 1 Quart 150 Cl 1 Gallon 2½ Gallon 5 Gallon 10 Gallon 11 Gallon 15 Gallon Design Modification (1st Digit) Blank Standard W Water/Chemical Service▲ M MS28889-2 Design (2nd Digit) A C D E G S Standard ASME (1 Gallon & up) SELO ASME (< 1 Gallon) CE Marking Appendix 22 Shell Special F Type of Construction B T Bottom Repairable Standard on all sizes Top Repairable Optional for 2½ Gallon and up ▲ Consult factory when using water/ chemical service with any port other than the standard SAE. If “U” stamp is required. NOTE: A. thru 15 Gal. documentation or any other certification must be requested at time of order.000 PSI (330 bar CE only) 4.M. H A Bladder/Seal Compound 01 04 06 08 28 Buna-Nitrile (Std. through 15 gal. Illinois USA .000 PSI 5. design.E.I. 1 Qt.S.E.E. Series Size Construction Gas Pressure Hyd.Catalog HY10-1630/US Model Code and Options How to Order Bladder Accumulators Bladder Accumulators Ordering Information Introduction Bladder accumulators and gas bottles can be specified by using the symbols in the chart below to develop a model number. – A. thru 15 Gal.000 PSI 5.S.S.S.. 79 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. (4K) 1 1/2” Code 62 (6000 PSI) 2½ Gal. thru 15 Gal.E. t u O g n i s a s t h u n o P i e r v r Hydraulic Port Design Code T Size Available 3000 5000 PSI PSI • • • • • • • • • • 10 Cl 1 Pint 1 Quart 150 Cl 1 Gallon 2½ Gallon 5 Gallon 10 Gallon 11 Gallon 15 Gallon U • • • • • F Type of Construction Bottom Repairable Standard on all sizes Conventional Top Repairable Optional for 2½ Gallon and up H A Working Pressure 3. available with “U” stamp. If “U” stamp is required. it must be specified at time of order. through 15 gal.Catalog HY10-1630/UStontent Phase Out Model Code Model Code Reference Bladder Accumulators Ordering Information Introduction The symbols in the chart below represent the Parker model numbering system which is being phased out. thru 15 Gal.) Hydrin (Optional) Butyl (Optional) EPR (Optional) Fluoroelastomer (Optional) * 1 Gal.15 Gallon. For current model numbers. NOTE: A. and 150 C. 1 Qt. Use this for reference only.600 PSI Special 3 4 5 6 S e Cu r P .000 PSI 6. 5000 psi Number given Design Modification (1st Digit) Blank Standard W Water/Chemical Service M MS28889-1 Design (2nd Digit) A Standard ASME (1 Gallon & up) ASME (< 1 Gallon) Appendix 22 Shell Special D G S Bladder/Seal Compound Buna-Nitrile (Std.E. refer to the previous page. design with “U” stamp. A.000 PSI 4.M.5 1 Pint & 1 Quart M27 x 2 150 Cl M33 x 2 1 Gallon M42 x 2 2½ Gallon thru 15 Gallon M48 x 2 Special 1 2 3 * Standard Standard 1 Quart 2½ . Illinois USA . – A.M. design. Series Size Construction Gas Pressure Hyd. 1 Pt.I. r e e o e f S ge Cod a l P de o M B X 1 9 3 7 5 R Y S SAE Straight Thread O-Ring (Standard) 10 Cl SAE #8 1 Pint & 1 Quart SAE #12 150 Cl SAE #16 1 Gallon SAE #20 2½ Gallon thru 10 Gallon SAE #24 NPT Pipe (No Cost Option) 10 Cl 3/4” NPT Male 1 Pint & 1 Quart 3/4” NPTF 150 Cl 1” NPTF 1 Gallon 1 1/4” NPTF 2½ Gallon thru 15 Gallon 2” NPTF SAE 4-Bolt Split Flange (No Cost Option) 10 Cl thru 150 Cl (3K) N/A 1 Gallon (3K) 1 1/4” Code 61 (3000 PSI) 2½ Gal. (5K) 1 1/2” Code 62 (6000 PSI) High Flow 4” NPT Male (Extra Cost Option) Available on 2½ Gallon thru 15 Gallon Sizes only (3000 PSI) High Flow 4 1/4-8 UN-2 Straight Thread Male (Extra Cost Option) Available on 2½ Gallon thru 15 Gallon Sizes only (3000 PSI) High Flow Flange Adapted to Above 4 1/4-8 UN-2 High Flow (Extra Cost Option) Available on 2½ Gallon thru 15 Gallon Sizes only (3000 PSI) NPT Pipe Undersized (No Cost Option) 2½ Gallon thru 15 Gallon Sizes only (3000 PSI) BSPP 10 Cl N/A 1 Pint & 1 Quart 3/4-14 150 Cl 1-11 1 Gallon 1 1/4-11 2½ Gallon thru 15 Gallon 2-11 ISO 6149-1 10 Cl M18 x 1.M. documentation or any other certification must be requested at time of order. Port1 Bladder/Seal Design Compound Modification Design Code AB Series AB BB TB Accumulator Gas Bottle Transfer Barrier 04 B 3 T 1 _A 1 003 005 01 03 04 10 20 40 44 60 B C . (3K) 2” Code 61 (3000 PSI) 2½ Gal.E. Illinois USA .Catalog HY10-1630/US Notes Bladder Accumulators Introduction 80 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Diaphragm Accumulators • AD Series Parker Diaphragm Accumulators Feature: • • • • • • Operating Pressures to 250 Bar Capacities from .075 to 2.80 Liters Compact and Lightweight Low Cost. Illinois USA . Non-Repairable Design Nitrile & Hydrin Diaphragms Durable Metric Gas Valve 81 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. and dampening pump pulsation and flow fluctuations.00 to 2.Catalog HY10-1630/US Introduction Diaphragm accumulators provide an affordable means of enhancing the performance of a hydraulic system. 0. and long service life in a lightweight.80 Normal Operation LPM GPM 40 11 100 26 160 42 When Fully Discharging LPM GPM 10 2. working pressure/precharge pressure): 8 to 1 on .4 liter. They are suitable for storing energy under pressure. lightweight safety. Diaphragm Accumulators AD Series Diaphragm accumulators provide dependable performance.32 to 1.075.075 liter through 1. Parker offers the latest in accumulator sizing technology with its inPHorm Accumulator Sizing and Selection Software. maximum efficiency. For your convenience. Compression Ratio (max. Parker’s broad standard offering includes piston. Why Use Diaphragm Accumulators? • • • • • • • • • • • improves system efficiency supplements pump flow supplies power in emergency compensates for leakage absorbs hydraulic shocks very contamination tolerant cost effective compact. Capacities and Dimensions for pressure ratings by size. compact design. specify charge pressure at the time of order.40 2. Available Options • Diaphragm Compounds • Gas Valves – M28 x 1. See diaphragm material options or consult factory for details. Illinois USA .6 40 11 60 16 Pressure Ratings – See Models.5 standard – ISO 4570-8VI gas valve (consult factory) • Hydraulic Ports – SAE standard – others (consult factory) 82 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. low lubricity fluids Parker Diaphragm Accumulators… Your #1 Choice! Parker is the leading manufacturer of accumulators in North America. Specifications Materials • Shell – high strength alloy steel • Ports – steel • Button – Delrin • Gas Valve Stem – steel • Diaphragms – Nitrile (NBR) or Hydrin (ECO) Max. absorbing hydraulic shocks. Precharge – Units are shipped with a nominal nitrogen precharge as standard. bladder and diaphragm accumulators. Fluids – Parker’s diaphragm accumulators are compatible with most petroleum-based industrial or water-based flame resistant fluids. non-repairable design very quick response works well with water. For specific precharge pressure. all rated at minimum 4 to 1 design factors.16 0. 4 to 1 on 2 liter and larger Maximum Flow Rates – Maximum Recommended Flow Rates Size (liters) 0. 9) SAE #8 1.65 (9/16 .48) 70 (2. 4 Fluid Port SAE straight thread for easy installation and leak-free service.) 64 (2.87) 22 (0.80 (170) MOP1 bar (PSI) 250 (3600) 250 (3600) 160 (2300) 160 (2300) 180 (2600) 250 (3600) 200 (2900) 250 (3600) 250 (3600) 250 (3600) A B C mm (in.75 (45) 1.76) 78 (3.2 (3/4 -16) (7.61) 41 (1.5 (3/4 . initial cost.43) 32 (1.2) SAE #8 1.48) 72 (2. See page110 for charging and guaging accessories.) SAE #6 0. (thread) (lb.18) (1.40 (85) 2.50 (30) 0.87) 22 (0.87) 22 (0. a low cost alternative to more complex and expensive valve-spring designs.7) SAE #8 6.3 (3/4 .16 (10) 0. 3 Button The button closes the fluid port when the accumulator is fully discharged to prevent diaphragm extrusion.16) (3.09) 198 (7.61) 41 (1.1) SAE #8 3.87) 22 (0.Catalog HY10-1630/US Features.3) SAE #8 2.5 gas valve is durable.16) (5. Gas Valve is also available.16) (13) SAE #8 7.00 (60) 1.18) 32 (1.26) 63 (2.16) (2.26) 41 (1.81) 180 (7.54) 173 (6. See model numbering information.87) 22 (0.61) 41 (1. Capacities and Dimensions Size liters (cu in) 0. Capacities and Dimensions Diaphragm Accumulators AD Series 5 1 2 3 4 1 Shell The shell is manufactured from a high strength alloy steel.88) 268 (10.35) 149 (5.80) 251 (9. Models. and.35 (20) 0.85) D E F Weight Port kg.16) (7.0 (9/16 . 2 Diaphragm The flexible diaphragm provides excellent gas and fluid separation.S.16) (17) SAE #8 10 (3/4 .5 (3/4 .10) 174 (6.18) (2.61) 41 (1.26) 32 (1.79) 22 (0.52) 75 (2.87) 30 (1.75 (45) 0. Diaphragms are available in two compounds.83) 72 (2.6) 20 (0.87) 166 (6.61) 41 (1. U.76) 127 (5. Nitrile (NBR) and Hydrin (ECO). Both provide excellent service with most mineral fluids with NBR being slightly lower cost and ECO offering excellent low-temperature performance for mobile applications.87) 22 (0.6 (3/4 . weight.79) 20 (0.075 (5) 0.61) 41 (1.87) 22 (0.83) 87 (3.62) 103 (4.19) 63 (2.35) 155 (6. leak-free and offers the flexibility of checking or charging the accumulator.10) 155 (6.72) 136 (5. Illinois USA .4) SAE #6 1. 83 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.37) 120 (4.06) 121 (4. ultimately.16) (22) Model AD007A25T1A1 AD016A25T1A1 AD032A16T1A1 AD050A16T1A1 AD075A18T1A1 AD075A25T1A1 AD100A20T1A1 AD140A25T1A1 AD200A25T1A1 AD280A25T1A1 111 (4.95) 92 (3.5 (3/4 .7) SAE #8 3.00 (120) 2. 5 Gas Valve Metric M28X1.07) 81 (3. The non-repairable electron-beam welded construction reduces size.61) 41 (1.0 (3/4 .00) 136 (5.61) C A D E HEX B F 1) Note: MOP = Maximum Operating Pressure. Catalog HY10-1630/US Options Diaphragm Accumulators AD Series Metric Gas Valve Parker AD Series diaphragm accumulators are fitted as standard with metric M28X1.5 gas valves. 1 1 1 1 1 Description Protective Cover Dyna Seal Valve Core Gas Valve Housing Gas Valve Seal 2 3 Assembly Part No. Gas Valve Parker AD Series diaphragm accumulators can be fitted with an optional US gas valve. and the types of fluids that are generally compatible. 582222 0000 135238 0000 870016 0000 Qty. L087001500 Item 3 4 5 Part No.5 charging and gauging assembly shown in Accumulator Accessories. Standard and Optional Diaphragm Materials Two diaphragm polymers are offered to suit a wide range of fluids and operating temperatures. This rugged gas valve features a internal hex locking screw with sealing washer. L08700150A Item 1 2 3 4 5 Part No. U. 84 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 1 1 1 Description Valve Core Gas Valve Housing Gas Valve Seal 4 5 NOTE: For assembly of gas valve to cap. Charging and pressure checking can be accomplished by utilizing standard charging and gauging assembly as shown in Accumulator Accessories. Illinois USA . The US gas valve features an internal gas valve core and a sealing washer.S. their recommended operating temperature ranges. The following table lists the optional polymers available. Temperature ranges may vary depending upon the fluid used in the hydraulic system. 1 Assembly Part No. 148146 0000 087036 0031 582222 0000 135238 0000 870016 0000 Qty. Charging and pressure checking can be accomplished by utilizing the M28X1. Seal Code 1 9 Polymer Nitrile (Buna-N) Hydrin (Lo-Temp) Recommended Operating Temperature Range 14°F to 176°F -10°C to 80°C -40°F to 176°F -40°C to 80°C Maximum Temperature with Reduced Life 200°F 93°C 200°F 93°C General Application & Compatibility1 Parker's Standard Compound – Compatible with most mineral oil based fluids Compatible with most mineral oil based fluids and maintains flexibility at low temps 1) Note: Consult your local Parker distributor or the factory for fluid compatibility information. use 9 ft/lbs. Gas Valve 25 T T SAE Straight Thread 1 9 1 Nitrile Hydrin A A Standard S Special 1 AD Series Diaphragm Accumulators Code Size 007 0.00 liter (120 in3) 280 2.80 liter (170 in3) MOP1 250 Bar (3600 PSI) 250 Bar (3600 PSI) 160 Bar (2300 PSI) 160 Bar (2300 PSI) 180 Bar (2600 PSI) 250 Bar (3600 PSI) 200 Bar (2900 PSI) 250 Bar (3600 PSI) 250 Bar (3600 PSI) 250 Bar (3600 PSI) 1 Standard * Special Design No.50 liter (30 in3) 075 0. Assigned 16 18 20 25 See "Size" for MOP1 Ratings 160 Bar (2300 PSI) 180 Bar (2600 PSI) 200 Bar (2900 PSI) 250 Bar (3600 PSI) 1) Note: Maximum Operating Pressure 85 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.32 liter (20 in3) 050 0.S. and place them in the sequence indicated by the example at the top of the chart.40 liter (85 in3) 200 2. Select only those symbols that represent the features desired.00 liter (60 in3) 140 1.16 liter (10 in3) 032 0.75 liter (45 in3) 075 0.Catalog HY10-1630/US Ordering Information How to Order Diaphragm Accumulators Diaphragm Accumulators AD Series AD Series diaphragm accumulators can be specified by using the symbols in the chart below to develop a model number. Illinois USA .075 liter (5 in3) 016 0.75 liter (45 in3) 100 1. Series Size Construction Pressure Port Diaphragm Variation Code AD 007 A A Std. Metric Gas Plug B U. Illinois USA .Catalog HY10-1630/US Notes Diaphragm Accumulators AD Series 86 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . BSPP . SAE or Split Flange Connections • Mounting in Any Position • 3000 PSI Models for Water/Chemical Service 87 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.Inline Pulse-Tone™ Hydraulic Shock Suppressors Inline Pulse-Tone™ Shock Suppressors Feature: • Three Bladder Polymers for a Wide Range of Fluids and Temperatures • NPT. Illinois USA .Catalog HY10-1630/US Introduction Page Inline Pulse-Tone™ Hydraulic Shock Suppressors The Patented Construction Nitrogen Charging Valve Oil Bladder Nitrogen Shock and Noise In Quiet Out Inner Chamber with 1/2” Holes Compressed Coil Spring Radial Flow Chamber with 1/32” Holes Bladder 88 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. and less noise. The bladder is usually charged with nitrogen to 50% to 60% of the hydraulic operating pressure. The pulsations are usually generated by the pump. but they frequently provide the primary path for propagating noise from the pump to components that. less expensive components . usually directly at the pump outlet. The 1/32” diameter holes in the last baffle are so small that the bladder cannot extrude into them. The lines do not generate noise. No complex sizing forumla is required. This slight deflection of the bladder reduces the shock and noise.Catalog HY10-1630/US Page Introduction Inline Pulse-Tone™ Hydraulic Shock Suppressors Why Should You Use the Shock Suppressor? It is almost impossible to forecast how much additional sound the hydraulic lines and surrounding structure will radiate. The Inline Pulse-Tone hydraulic shock suppressor is sized to match your hydraulic line size. Not only do hydraulic lines radiate noise. Illinois USA . . you stop the cause of component wear and leakage. Models are available for both 3000 PSI and 5000 PSI hydraulic system pressures. This helps explain why many pump manufacturers have a very low dB(A) pump rating. NOTE OF INTEREST: An increase of 2. How Does the Work? As shown in the diagram on the facing page. The total radial distance through these baffles is only 1/4”. in turn. oil flowing into the Pulse-Tone goes through three different baffles or diffusers. This is why many power units are enclosed after they have been manufactured and installed. An Inline Pulse-Tone suppressor is located as close to the pump as possible.71 dB doubles the intensity noise level. The large area of the bladder. There is a unit to fit 89 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. The bladder deflects each time it is hit by a pulsation. They radiate noise when they respond to pulsations or vibrations. and the vibrations are radiated by large flat machine surfaces. Lab tests show that pump noise levels are increased by 2-3 dB(A) just by adding 12 feet of outlet and return lines. the sound rating is much higher. but when the pump is installed on a power unit. When you stop pulsation and vibration. Selecting a is Easy! every pipe and tube size from 3/8” to 2” with threaded or flanged connections. react to the noise and radiate additional sound. to stop pulsations and noise before they travel through the piping and radiate off other structural components. . A power unit with an Inline Pulse-Tone installed can operate at higher RPM with smaller. The Inline Pulse-Tone reduces pump pulsations and shock. After passing through these holes. These metal baffles are designed to convert 1/2” diameter holes to 1/32” diameter holes. Noise pollution is the hottest topic in the hydraulic industry today. pulsations strike a nitrogen charged rubber bladder. its ability to oscillate at a high frequency and the short distance each pulsation has to travel once it enters the unit explain the effectiveness of the Pulse-Tone. Illinois USA . Compact size Special materials for water or chemical service Can be supplied with customer specified precharge Short delivery times Low maintenance costs Ease of installation Mounting ease and flexibility Ease of installation Easily added to existing power units Longer life and wider variety of applications Shorter installation time Lower operating costs 90 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Benefits Inline Pulse-Tone™ Hydraulic Shock Suppressors Features Reduces pulsations and shock Advantages Less component wear and system leakage Better work environment Eliminates need for sound proofing Use smaller. higher RPM components Smaller motor starters Nothing to break Accommodates both hose and tube sizes Allows for installation of larger units Cannot be installed backwards Allows for mounting close to pump Resists corrosion Ease and speed of adjusting to system parameters Eliminates customer inventory Benefits Less maintenance Higher worker morale and productivity Lower system costs Design flexibility Reduces noise No moving mechanical parts Wide range of port sizes Flange mountings Unit is bidirectional.Catalog HY10-1630/US Features. Page Advantages. -50° to 300°F (-45° to 149°C) • Fluorocarbon or EPR bladders are available for special applications 420 psi Before Precharge The unit can be shipped with a nitrogen precharge equal to 50% of hydraulic system pressure. When ordering. (See page 184 for procedures. such as a split flange one end and a straight thread on the opposite end. 5. specify the type of connection for each end.Catalog HY10-1630/US Page General Information Models • 3000 psi rated for oil applications • 3000 psi Stainless Steel for water and chemical applications • 5000 psi for high pressure oil applications Inline Pulse-Tone™ Hydraulic Shock Suppressors Examples of Pulsation Reduction The examples below show pulsations for pumps at various pressures before and after installation of the Inline Pulse-Tone. either end may be used for inlet or outlet. 180 HZ 75 psi Before 12 psi After Piston Pump at 750 psi and 1200 rpm 91 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 235 psi Before 25 psi After Piston Pump at 4000 psi and 1800 rpm Bladder Materials • Standard material is high temperature HNBR. Port Connections Four types of hydraulic line connections are available: • NPT pipe connections from 3/8” to 2” pipe • BSPP connections from 3/8” to 2” pipe • SAE port connection from 3/8” to 2” tubing • Split flange connection from 3/4” to 3” Inline Pulse-Tone units can be ordered with any combination of ends. Since there are no moving parts. Illinois USA .) 40 psi After Piston Pump at 2000 psi and 1800 rpm Mounting The Pulse-Tone may be mounted in any position.55 MSEC. Check precharge every three months to maintain maximum efficiency. horizontal or vertical. Split flange mounting makes it possible to break an existing connection to add the Pulse-Tone between the flanges. 500 .7) Weight lbs.1) 31 (14.750 1.1 PT400D1H 68.4) 10.5) L 6.5) 1.1) 31 (14.13 (206.75 (44.5) 8.6) 8.625 (66.875 (174.1) PT262D1H 24.625 (66.75 (44.5) 1.6) 4. Flow rates can be at least 50% higher than those listed for 20’/sec.5) 1.7) 4.3 Flow.875 (174.6) 24. without excessive pressure drop.1 PT400D1H 68.00 Thread 9/16–18 3/4–16 7/8–14 1-1/16–12 1-5/16–12 1-5/8–12 1-5/16–12 1-5/8–12 1-7/8–12 2-1/2–12 Flow.25 1. inch (mm) D 2.1 Dimensions.75 (44.9 128.7) Weight lbs. GPM 15’/sec 11.75 (44.0 171.13 (206.375 .5) 2.1 Dimensions.00 1.75 (120.5) L 6. Illinois USA .75 (120.6) 8.0 * Pressure drop in the suppressor is equal to pressure drop in 8” of tubing.Catalog HY10-1630/US 3000 Page PSI with Threaded Connections Inline Pulse-Tone™ Hydraulic Shock Suppressors L H Thread Size D 3000 PSI Pipe Thread Connections Model PT250D1H PT262D1H NPT Size 3/8 1/2 3/4 1 — 1 1¼ 1½ 1½ 2 BSPP Size 3/8 1/2 3/4 1 1¼ 1 1¼ 1½ 1½ 2 Flow.75 (44.7) H 1.2 32.0 (101.75 (44.875 (225.5) 1.0 PT475D1H 3000 PSI Straight Thread Connections Model PT250D1H Tube Size .0 (3.6) 24.7) 4.3 Flow.50 2. GPM 15’/sec 11. GPM 20’/sec* 15.75 (44. inch (mm) D 2.75 (44.5 (63.0 (101.7) H 1.5) 1.625 .1 32. (kg) 6.4) 10.5 (3) 8. 92 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.9 91.5) 2.5 (3) 8 (3.9 PT475D1H 128.5) 8.5 (11.6) 4.00 1.5 (11.0 91.5 (266.5 (266.25 1.1) 24. GPM 20’/sec* 15.5) 1.875 (225.9 171.5 (63. (kg) 6. 00 1.6) 24.5 (11. without excessive pressure drop.0 (101.750 1.5) 8. GPM 20’/sec* 32. 93 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.75 (44.6) 24.1 Dimensions.875 (225.5) L 8. Illinois USA . (kg) 8. GPM 20’/sec* 32.4) Weight lbs.75 (44.5) 1.25 1.25 1.6) H 1.9 * Pressure drop in the suppressor is equal to pressure drop in 8” of tubing. (kg) 8 (3.Catalog HY10-1630/US Page PSI Water/Chemical Service 3000 Tube Nickel Plated Inside and Out Inline Pulse-Tone™ Hydraulic Shock Suppressors “304” Stainless End Pieces Cutaway Three “304” Stainless Steel Chambers L H Thread Size D 3000 PSI Pipe Thread Connections Model PT262D3H NPT Size 3/4” 1” 1” 1¼” 1½” Flow.50 Thread 1-1/16–12 1-5/16–12 1-5/8–12 1-5/16–12 1-5/8–12 1-7/8–12 Flow.9 Flow.75 (44. GPM 15’/sec 24.5 (11.75 (44.9 91. inch (mm) D 2.2 68.625 (66.1) PT400D3H 68.1 Flow.4) Weight lbs.00 1.6) H 1.875 (225.5) 1.9 Dimensions. inch (mm) D 2. GPM 15’/sec 24.7) 4. Flow rates can be at least 50% higher than those listed for 20’/sec.0 (101.5) L 8.625 (66.0 (3.1 91.1) PT400D3H 3000 PSI Straight Thread Connections Model PT262D3H Tube Size .13 (206.13 (206.5) 8.7) 4. 0) 10.688 (42.75 (425.1) 2.7) 11.250 (57.312 (58.8) 1.188 (106.25 1.38 (60.812 (96.620 (66.06 (26.4) 13.12 (333.8) 3.120 (282.56 (14.8) 1.62 (15.75 (19.6) A 1.2) .4) E 1.6) 4.0) 10.062 (52.4) 2.5) 2.1) 2.2) 1.88 (22.4) 2.875 (352.9) 1.44 (36. *** Maximum pressure rating for this flange is 2000 psi.00*** Code 61 Flange D 2.9) 1.6) 4.7) 3.25 (57.250 (31.125 (333.75 (44.8) — — F 0.062 (77.75 (120.4) 13.94 (23.250 (57.7) .62 (15.938 (23.00 (101.094 (27.7) 4.062 (77.250 (57.2) 13.00 2.6) 4.620 (269.1) 2.000 (50.00 (101.4) 13.9) 2.7) 2.1) 2.620 (66.7) 2.4) — — E 2.9) 1.62 (15.406 (35.75 (19.4) F 0.750 (44. Illinois USA .625 (66.8) 3.56 (14.8) 1.50 2.2) 1.3) L 10.62 (15.9) 3.030 (26.4) 2.8) 3.Catalog HY10-1630/US 3000 Page PSI Flange Mounted L Inline Pulse-Tone™ Hydraulic Shock Suppressors 1.125 (79.8) 2.44 (36. A B E L F Ordering Note The Pulse-Tone flange mounted unit is not supplied with split flanges. 94 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.000 (50.6) B .06 (26.7) 10. do not exceed 3000 psi pressure rating of the unit.500 (88.75 (120.25 PT400D1HP 1.9) 15.6) 4.8) 2.00 (406.00 (101.250 (31.8) 2.438 (36.1) .7) .6) 2.625 (346.7) 2.4) 3.750 (69.1) 13.12 (257.2) 1. ** Maximum pressure rating for this flange is 2500 psi.5) 1.6) — — L 10.875 (47.875 (73.9) 1.438 (61.00 1.25 (82.812 (96.00 PT475D1HP 2.000 (50.5) 2.5) — — Code 62 Flange* B .56 (14.2) .000 (50.0) .5) 1.4) 16.25 (57.1) 2.0) 16.625 (66.12 (333.50** 3.7) 13.2) 1.7) 2.625 (66.0) 3.875 (22.75 (44.00 (50.38 (339.1) 2.75 (120.2) .5) 1.188 (30.7) 2.750 (44.7) 1.6) 1.8) 2.19 (30.5) — — * When using Code 62 flanges.2) 1.620 (269.75 PT262D1HP 1.250 (57.9) 4.2) 13.875 (352.7) .6) 4.38 (60.5) Flange Size D 3000 PSI for Code 61 Flange Mounting Model Flange Size 0.9) A 2.7) .625 (66.8) 1.12 (257.312 (58.188 (30.8) 2.688 (42.00 (381.62 (269.625 (66.75 (44. 06 (26.5) 2.44 (35.19 (30.5) Flange Size D 5000 PSI for Flange Mounting Model Number Flange Size 1.50 2.125 (333.8) 1.2) 2.4) 3.6) D 3.94 (23.5) A B E L F Ordering Note The Pulse-Tone flange mounted unit is not supplied with split flanges. Illinois USA .8) 1.250 (57.00 Code 62 Flange* Dimensions.00 (127.438 (36.625 (66.25 PT500C1HP 1.00 (127.250 (31.625 (346.8) 5.125 (79.4) 13.875 (352.7) 11.625 (66.0) 5. inch (mm) A 2.38 (85.9) 1.8) F 1. 95 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.00 (127.8) 3.094 (27.28 (32.00 PT338C1HP 1.620 (66.8) 1.38 (85.250 (31.750 (44.250 (57.5) 1.9) 1.9) 1.8) 2.250 (57.7) 3.1) 13.7) 2.620 (269.120 (282.812 (96.2) 1.4) E 2.0) 5.4) 13.0) L 10.2) 2.Catalog HY10-1630/US Page PSI Flange Mounted 5000 L Inline Pulse-Tone™ Hydraulic Shock Suppressors 1.5) B .06 (26.2) 2.25 1.000 (50.500 (63. 88 (225.25 1.750 1. Order by series and seal material.28 (32.38 (85.8) 5.00 1.8) PT500C1H 150 GPM * Pressure drop in unit is equal to pressure drop of 8” of tubing.5) 8. (kg) 15 (6.0 (127. Series 250 262 & 338 400 & 500 475 HNBR RKPT2500H0 RKPT2620H0 RKPT4000H0 RKPT4750H0 EPR RKPT2500D0 RKPT2620D0 RKPT4000D0 RKPT4750D0 Fluorocarbon RKPT2500E0 RKPT2620E0 RKPT4000E0 RKPT4750E0 96 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.28 (32. Repair Kits Repair kits include a bladder and o-rings.25 1.Catalog HY10-1630/US 5000 Page PSI Threaded Connection Inline Pulse-Tone™ Hydraulic Shock Suppressors L H Thread Size D 5000 PSI Straight Thread Connections Model PT338C1H For Tube Suppressor .5) L 8. Flow rates can be at least 50% higher than those listed for 20’/sec without excessive pressure drop.36) 48 (21.00 1.5) 1. inch (mm) D 3.50 Thread In Rate 1-1/16–12 1-5/16–12 1-5/8–12 1-5/16–12 1-5/8–12 1-7/8–12 Maximum Flow 49 GPM Dimensions.6) Weight lbs.13 (206. Illinois USA .0) H 1. Maximum pressure rating for the 3” flange is 2000 PSI. leave blank. Select only those symbols that represent the features desired and place them in the sequence indicated by the example at the top of the chart.75” Dia. 262 2. **When ordering different flange port sizes. ◆ Maximum pressure rating for the 2½” flange is 2500 PSI. Specify left hand port first if ports are not the same. If not desired. 5. specify port that connects to the pump first. Design 1 Standard 3 Water/Chem Service* S Special * Available in Sizes 262 and 400 only.50” Dia. indicate pressure in psi. 3000 PSI Sizes 250 2.50”) size.625” Dia.00” Dia 475 4. Illinois USA Inline Pulse-Tone™ . T Port Type SAE Port Size B C I D E F G H T U V W X Y Z A B C D E F G U V W J L M N K G H P Q SAE #6 (9/16-18) SAE #8 (3/4-16) SAE #10 (7/8-14) SAE #12 (1-1/16-12) SAE #16 (1-5/16-12) SAE #20 (1-5/8-12) SAE #24 (1-7/8-12) SAE #32 (2-1/2-12) 3/8” 1/2” 3/4” 1” 1¼” 1½” 2” 3/8” 1/2” 3/4” 1” 1¼” 1½” 2” 3/4” 1” 1¼” 1½” 2” 2½” 3” 3/4” 1” 1¼” 1½” 2” U NPT Port Availability SAE Size 250 262 400 475 338 500 ● ● ● NPT/BSPP Size 250 262 400 475 338 500 ▲ ▲ ▲ ▲ ▲ ▲ 3/8 ● 1/2 ● ★ ★ ★ ▲ ★ ★ ● ● ▲ BSPP only ★ Available for Water/ Chemical Service (NPT only) P Code 62** Split Flange 3/4 1 1¼ 1½ 2 ● ● ● P Code 61** Split Flange #6 ● #8 ● #10 #12 ● ■ ■ ■ ■ ■ ■ ● ■ Available for Water/Chemical Service #16 #20 #24 #32 R BSPP Parallel Flange Availability Code 61 Size 262 400 475 3/4 ● 1 ● 1¼ ● ● ● ● ● Code 62 Size 338 500 3/4 ● 1 ● 1¼ ● ● ● ● 1½ 2 ◆ ◆ 1½ 2 2½ 3 * Different type and size hydraulic ports may be ordered for each end. – – – – — Precharge Pressure* If desired. * Provided at additional cost.Catalog HY10-1630/US Page Ordering Information How to Order Inline Pulse-Tone™ Hydraulic Shock Suppressors Use the symbols in the chart below to develop an Inline Pulse-Tone model number. 400 4.00” Dia.375” Dia. 97 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Hydraulic Ports* Size Type Size Precharge Pressure* Series Size Pressure Design Seals Type PT 250 D Pressure D C 3000 PSI 5000 PSI 1 H Seals D EPR* E Fluorocarbon H HNBR (STD) * Not available on 250 (2. 5000 PSI Sizes 338 500 3. Catalog HY10-1630/US Charging Page and Gauging Accessories Charging & Gauging Assemblies Includes 10 ft. bleeder valve and gas chuck and gauge. adapter incorporating gas valve.1000 PSI 0 .6000 PSI 98 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Part Number 087040 1000 087040 2000 087040 3000 087040 4000 087040 5000 087040 6000 Pressure Range 0 .2000 PSI 0 . charging hose with standard right-hand thread nitrogen fittings. Inline Pulse-Tone™ Hydraulic Shock Suppressors For 3000 PSI 144595 300C (Std) 144596 300C (Left Hand Thread) For 5000 PSI 144912 600C Charging & Gauging Assemblies are sold in plastic carrying case.4000 PSI 0 . Listed below are 2½" dial type pressure gauges with 100 PSI graduation.5000 PSI 0 .3000 PSI 0 . Gauges Gauges may be ordered separately. Illinois USA . Include blowout safety case and orifice surge damper. 1) Dimensions.37 x 0.25 (133.50 1.25 (41.42 (112.37 x 0.6) 3.1) (125.1) (81.25 (107.9) ∅L Z 1.9) 5.37 x 0. D .3) (9.4 x 12.82 (66.9) (9.25 (133.5/104.45 0.92 7.02/5.25 (146.5/71.25 4.94 5.1) (62.Catalog HY10-1630/US Page Accessories & Spare Parts Mounting Clamps Inline Pulse-Tone™ Hydraulic Shock Suppressors .8) 3. Illinois USA .43 5.8) 5.4 x 12.21 0.13 Typ.5/135.6/124.50 1.4) (109. 8700110252 8700110358 8700110413 8700110476 8700110535 A 4.25 (57.28 0.37 x 0.64 0.9) (97.7) (127.50 1.2 4 Rubber Sleeve Z Width B A Clamp Dimensions Series 252 338 400 475 500 Part No.0) (188. H ∅L (2) C Ref.2) (153.11 2.62 (100.2) (9.8) 99 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.4 x 12.35 (85. inch (mm) C D H 4.32 3.71 4.50 (82.67/4.7) (31.50 1.33 6.50 1.6/88.4) (109.84/4.3) 2.5) (9.4 x 12.7) (31.77 0.1) (142.7) (9.7) (31.25 4.8) 5.06 3.7) 5.62/2.25/3.2) (170.7) (31.8) 2.90 2.75 4.33 6.7) (31.4) (118.37 x 0.00 (127) B 3.5) (70.4 x 12. Illinois USA .Catalog HY10-1630/US Notes Page Inline Pulse-Tone™ Hydraulic Shock Suppressors 100 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Large Gas Bottles • Series GB GB Series Large Gas Bottles Feature: • • • • Capacities from 40 to 150 Gallons High Strength Alloy Steel with Forged Ends Large 16" Diameter Shells Variety of Port Options 101 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . and special ports are available as options. Why Use GB Series Gas Bottles? • reduce initial hydraulic system costs • broad range of sizes and operating pressures • heavy duty forged construction • minimize plumbing with fewer large bottles • interface well with Parker’s accumulator products. Illinois USA . Metric flange. See Models. Parker’s broad product line includes piston accumulators. a smaller accumulator may be used by connecting it to a gas bottle(s) that can be located in a nearby spot where space is available. Optional Gas Valve – GB Series gas bottles are supplied as standard with high pressure cored gas valve cartridges (ISO4570-8V1). MS28889-2) are available as an option. See page 3 for a complete certifications summary. 1. Appendix 22 Certification. Poppet type (military) gas valves (Mil. Standard and Optional Ports – GB Series gas bottles are offered with 2" SAE 4-bolt flange ports as standard. especially with large capacity applications. exterior coated with primer. In some cases. Certifications – GB Series gas bottles are supplied as standard with ASME Section VIII Div. see next page for details. Spec. • Ports – steel • Gas Valve Cartridge – stainless steel Pressure Ratings – Parker’s GB Series offers 3200 psi and 5500 PSI gas bottles rated at minimum 3 to 1 design factors. an accumulator and gas bottle combination may be lower in cost. Parker’s broad gas bottle offering includes: • Large GB Series gas bottles (shown here) • Piston Type Bottles (see Piston Accumulators ) • Bladder Type Bottles (see Bladder Accumulators) Specifications Materials • Shell – high strength alloy steel. 102 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Capacities and Dimensions for specific pressure ratings by size. and diaphragm accumulators.Catalog HY10-1630/US Introduction Large Gas Bottles Series GB Where space does not permit the installation of the required capacity accumulator. bladder accumulators. SA-372. SAE straight thread. Temperatures from -20°F to 200°F (-29°C to 93°C). In addition to gas bottles. especially piston accumulators Parker GB Series Gas Bottles… The Right Choice! Parker is the leading manufacturer of accumulators in North America. Size 2" Code 62 SAE Flange 2" Code 62 SAE Flange 2" Code 62 SAE Flange 2" Code 62 SAE Flange 2" Code 62 SAE Flange 2" Code 62 SAE Flange 2" Code 62 SAE Flange 2" Code 62 SAE Flange 2" Code 62 SAE Flange Weight lbs.8) 70 (264.062 3.0) 60 (226.2B 103 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. (mm) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) B in.2B 3/4-10 UNC . (mm) 69 (1753) 82 (2083) 96 (2438) 110 (2794) 123 (3124) 136 (3454) 150 (3810) 184 (4674) 218 (5537) C Port Size 2" Code 61 SAE Flange 2" Code 61 SAE Flange 2" Code 61 SAE Flange 2" Code 61 SAE Flange 2" Code 61 SAE Flange 2" Code 61 SAE Flange 2" Code 61 SAE Flange 2" Code 61 SAE Flange 2" Code 61 SAE Flange Weight lbs.750 E 3.812 F 1/2-13 UNC .6) 80 (302.4) 90 (340) 100 (378) 125 (473) 150 (567) A in. Capacities and Dimensions Large Gas Bottles Series GB 3200 PSI (220 Bar) Capacity Gallons (Liters) 40 (151.0) 60 (226.0 D 1. (kg) 660 (300) 785 (357) 912 (415) 1043 (474) 1175 (534) 1300 (591) 1436 (653) 1755 (798) 2075 (943) Model GB16040A32PL1A1 GB16050A32PL1A1 GB16060A32PL1A1 GB16070A32PL1A1 GB16080A32PL1A1 GB16090A32PL1A1 GB16100A32PL1A1 GB16125A32PL1A1 GB16150A32PL1A1 A B 5500 PSI (380 Bar) Capacity Gallons (Liters) 40 (151.Catalog HY10-1630/US Models.0 2.8) 70 (264. (mm) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) B in.6) 80 (302. (kg) 1180 (536) 1420 (645) 1650 (750) 1898 (863) 2128 (967) 2358 (1072) 2606 (1185) 3190 (1450) 3795 (1725) Model GB16040A55PQ1A1 GB16050A55PQ1A1 GB16060A55PQ1A1 GB16070A55PQ1A1 GB16080A55PQ1A1 GB16090A55PQ1A1 GB16100A55PQ1A1 GB16125A55PQ1A1 GB16150A55PQ1A1 F C E D Port Size 2" SAE Code 61 2" SAE Code 62 C 2.4) 90 (340) 100 (378) 125 (473) 150 (567) A in. (mm) 77 (1956) 92 (2337) 108 (2743) 123 (3124) 138 (3505) 153 (3886) 168 (4267) 207 (5258) 244 (6198) C Port Size Thd. Illinois USA .2) 50 (189.688 1.2) 50 (189. three different choices are possible: • A single accumulator with the required gas capacity. Assigned PJ PL PM PP PQ TE TF TG 1-1/2" Code 61 Flange 2" Code 61 Flange 2-1/2" Code 61 Flange 1-1/2" Code 62 Flange 2" Code 62 Flange SAE #16 SAE #20 SAE #24 1 None Gas Valve Option (or 2nd Port Options): • M Military Poppet Style Gas Valve . 70 gallon 16". Example: Using the inPHorm Accumulator Sizing and Selection Software. 150 gallon 1 Standard • Special Design No. a required accumulator capacity or volume is calculated. When selecting an accumulator(s) to satisfy the requirement. 100 gallon 16". with the required total combined gas capacity. When sizing an accumulator with gas bottle(s) system. Illinois USA . • A single smaller accumulator with gas bottle(s) with the required total combined gas capacity. You know that 16 gallons of fluid will be discharged during operation.Standard on all ** Ref. • Multiple smaller accumulators. make your selection such that the bottle(s) capacity plus the accumulator gas capacity will equal the total gas capacity required. Gas Port1 Gas Valve Port Design Variation Design Code Series Size Construction Pressure Options GB 16040 A A Standard 32 32 3200 PSI 55 5500 PSI PL M 1 A A Standard S Special 1 GB Gas Bottles 16040 16050 16060 16070 16080 16090 16100 16125 16150 16". This calculated capacity is the total “gas” volume required to discharge a specified amount of fluid at a given pressure differential and temperature. 80 gallon 16". 40 gallon 16". 125 gallon 16". and place them in the sequence indicated by the example at the top of the chart. 104 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Large Gas Bottles Series GB How to Order Gas Bottles GB Series gas bottles can be specified by using the symbols in the chart below to develop a model number. you calculated that you need an accumulator with an 80 gallon gas capacity. 60 gallon 16". When selecting a gas bottle(s). for large capacity applications the single smaller accumulator with gas bottle(s) usually proves to be the most cost effective. care must be taken when selecting the accumulator to insure that the piston does not bottom out on the end caps when being charged with or when discharging fluid. Though all three of the above choices have their advantages. As a rule of thumb. plumbed in parallel. 90 gallon 16". 50 gallon 16".Catalog HY10-1630/US Sizing & Ordering Information Gas Bottle and Accumulator Sizing Information When hydro-pneumatic accumulators are sized. size the accumulator with 20% to 25% greater capacity than the volume of fluid being discharged during operation. Additional Port Code per Gas Port Codes 1) See page 103 for flange port dimensions. The proper selection would be a 20 gallon accumulator with a 60 gallon gas bottle. Select only those symbols that represent the features desired. Illinois USA .Accumulator Accessories • Charging & Gauging Assemblies • Unloading Valves • Mounting Kits • Port Adapters • Repair Tools Accessories for: • • • • • • Piston Accumulators Bladder Accumulators Diaphragm Accumulators Gas Bottles SurgeKushons PulseTones 105 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 085434 0000 ** Used primarily for top repairable accumulators and/or permanent mount gage. 144595 0000 (Std) 144596 0000 (Left Hand Thread) 087100 0000 Assemblies Packed in Carrying Case 148675 0000 870816 0000 3000 PSI Charging & Gauging Assemblies (with 3000 PSI Gauge) Part Piston Bladder Number Style Style 144595 3000 All All* 144596 3000 All All* 148675 3000 — — 087100 3000 — 1-15 gal. Illinois USA 106 .Catalog HY10-1630/US Charging and Gauging Assemblies Charging & Gauging Assemblies Hydraulic Accumulators Accumulator Accessories Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings. adapter incorporating gas valve. Gauge not included.2000 PSI 0 . Assemblies are packed in a plastic storage case.1000 PSI 0 . Diaphragm Style with Cored valve with Cored valve with M28 valve — — — Gauges Gauges are 2½" dial type pressure gauges with 100 PSI graduation. valve extension part #085434 0000 would be required.4000 PSI 0 . Part Number 087040 1000 087040 2000 087040 3000 087040 4000 087040 6000 Pressure Range 0 .3000 PSI 0 . bleeder valve and gas chuck.6000 PSI Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. not included. Include blowout safety case and orifice surge damper.** 087102 3000 — 10-150 CI** 4000/5000 PSI Charging & Gauging Assemblies (with 5000 PSI Gauge) 870816 5000 All All * For top repairable styles. see Gauging Adapters. No Gauge Gauging Assembly.5" Pressure Gauge SAE #6 Gas Valve Extension Case with Insert for Complete Charging and Gauging Assembly Gasket for 5422150000 (5) Gasket for 5420860000 (6) 107 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 1/8 EXT. For continuous monitoring. Consult factory for further information. 1/4 FEMALE EXT. PRESSURE GAUGE 1/4 EXT. PIPE THD.305–32 EXT. between Gas Chuck (5) and Adapter Cross (1). No Gauge Standard Assembly RH Connection with 500 PSI Gauge Standard Assembly RH Connection with 1000 PSI Gauge Standard Assembly RH Connection with 2000 PSI Gauge Standard Assembly RH Connection with 3000 PSI Gauge Optional Assembly with Left Hand (LH) Nitrogen Bottle Connection. PIPE THD.305–32 UNS VIEW AA NITROGEN BOTTLE CONNECTION .Catalog HY10-1630/US Charging and Gauging Assemblies Hydraulic Accumulators Accumulator Accessories The following assemblies and parts are recommended for use on all 3000 PSI Piston Accumulators and 3000 PSI Bottom Repairable Bladder Accumulators. PIPE THREAD 1/8 EXT. 2 1/2 IN. . THD. NOTE: Can be used on all accumulators with a gas precharge less than 3000 PSI. Can be used with 3000 PSI Top Repairable Accumulators. Illinois USA Accessories . No Hose or Gauge Optional Gauging assembly w/ 2" Hose Ext. . Item 1-10 1-11 1-11 1-11 1-11 1-10L 1-5 1-5H 6-10 6-10L 1 2 3 5* 6** 7 9 9L 10 11 * ** Part Number 1445950000 1445950500 1445951000 1445952000 1445953000 1445960000 0851220000 5420880000 1457810000 1457820000 5420910000 5420920000 0832140000 8708150000 5420860000 0870520000 6661250000 6661260000 6661240000 See Gauges 0854340000 1333290000 5824390000 8702770000 Description Standard Assembly with Right Hand (RH) Nitrogen Bottle Connection. NOTE: These assemblies are not recommended for continuous monitoring of gas precharge. PIPE THD. No Hose or Gauge Hose Assembly with RH Connection Hose Assembly with LH Connection Adapter Cross Gas Valve with 1/8" NPT Bleeder Valve Gas Chuck Hose Coupling with Female Thread Connection Charging Hose Nitrogen Bottle Nut with RH Connection Nitrogen Bottle Nut with LH Connection Nitrogen Bottle Nipple 2. THD.960–14 R. but require a Gas Valve Extension.H. H. No Gauge Standard Assembly for 10 to 150 Cubic Inch with RH Connection with 1000 PSI Gauge Standard Assembly for 10 to 150 Cubic Inch with RH Connection with 2000 PSI Gauge Standard Assembly for 10 to 150 Cubic Inch with RH Connection with 3000 PSI Gauge Standard Assembly for 1 to 15 Gallon with RH Nitrogen Bottle Connection. NITROGEN BOTTLE CONNECTION . .960-14 R. 2 1/2 IN.305-32 EXT. 1/8 EXT. THD. The following assemblies and parts are recommended for use on all 3000 PSI Bladder Accumulators. see Gauging Adapters.Catalog HY10-1630/US Charging and Gauging Assemblies Hydraulic Accumulators Accumulator Accessories 1/8 EXT. PRESSURE GAUGE 1/4 FEMALE EXT. No Gauge Standard Assembly for 1 to 15 Gallon with RH Connection with 1000 PSI Gauge Standard Assembly for 1 to 15 Gallon with RH Connection with 2000 PSI Gauge Standard Assembly for 1 to 15 Gallon with RH Connection with 3000 PSI Gauge Gauging Assembly for 10 to 150 Cubic Inch (No Hose or Gauge) Gauging Assembly for 1to 15 Gallon (No Hose or Gauge) Hose Assembly with RH Connection Gas Chuck Body for 10 to 150 Cubic Inch Gas Chuck Body for 1 to 15 Gallon Gas Valve with 1/8" NPT Bleeder Valve Hose Coupling with 0. THD.305-32 Female Thread Connection Charging Hose Nitrogen Bottle Nut with RH Connection Nitrogen Bottle Nipple 2. PIPE THD. PIPE THD. Cannot be used with Piston Accumulators. 1/4 EXT. Illinois USA .5" Pressure Gauge Gasket for 5420860000 (6) Case with Insert for Complete Charging and Gauging Assembly 108 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Item 1-10 1-11 1-11 1-11 1-10 1-11 1-11 1-11 1S-5 1-5 6-10 1S 1 2 3 6* 7 9 10 11 * Part Number 0871020000 0871021000 0871022000 0871023000 0871000000 0871001000 0871002000 0871003000 0871030000 0871010000 1457810000 4000450000 4017740000 5420920000 0832140000 5420860000 0870520000 6661250000 6661240000 See Gauges 8702770000 1353290000 Description Standard Assembly for 10 to 150 Cubic Inch with RH Nitrogen Bottle Connection. PIPE THD. 5/8-18 UNF-2B 10 CI – 150 CI 7/8-14 UNF-2B 1 – 15 GALLON NOTE: These assemblies are not recommended for continuous monitoring of gas precharge. PIPE THD. For continuous monitoring. PIPE THD. PIPE THD. see Gauging Adapters.H.305–32 FEMALE TH’D 1/4 EXT. THD.) 2. 1/8 EXT. For continuous monitoring. FEMALE TH’D Item 1-8 1-9 1-9 1-4 5-8 1 2 3 4 5 6 7 8 9 Part Number 8708160000 8708165000 8708166000 8713720000 8712640000 8708460000 L07688000K 8708140000 8708150000 0854210000 0854220000 0854250000 0854150000 See Gauges Description Standard Assembly with Left Hand (LH) Connection. 5000 PSI Top Repairable Accumulators require a Gas Valve Extension.5" Pressure Gauge 109 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Hydraulic Accumulators Accumulator Accessories NOTE: These assemblies are not recommended for continuous monitoring of gas precharge. 2 1/2 IN.Catalog HY10-1630/US Charging and Gauging Assemblies The following assemblies and parts are recommended for use on all 5000 PSI Piston Accumulators and all 5000 PSI Bladder Accumulators. No Gauge Standard Assembly LH Connection with 5000 PSI Gauge Standard Assembly LH Connection with 6000 PSI Gauge Gauging Assembly (No Hose or Gauge) Hose Assembly with LH Connection Adapter Cross Gas Valve Assembly Bleed Valve Gas Chuck Valve Connector Nitrogen Bottle Nut with LH Connection Gas Tank Nipple (Cga 677) Charging Hose (10 ft. . Consult factory for further information.305–32 EXT. Illinois USA Accessories .035–14 L. PRESSURE GAUGE . NOTE: Can be used on all accumulators with a gas precharge less than 5000 PSI. 1. PIPE THD. NITROGEN BOTTLE CONNECTION . Illinois USA . NOTE: These assemblies are not recommended for continuous monitoring of gas precharge.960–14 R. 1/8” EXT.H. see Gauging Adapters.5" Pressure Gauge Gasket for 5420860000 (6) Case with Insert for Complete Charging and Gauging Assembly 110 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.Catalog HY10-1630/US Charging and Gauging Assemblies The following assemblies and parts are recommended for use on all Diaphragm Accumulators with M28 Gas Valve. Hydraulic Accumulators Accumulator Accessories . No Gauge Standard Assembly RH Connection with 1000 PSI Gauge Standard Assembly RH Connection with 2000 PSI Gauge Standard Assembly RH Connection with 3000 PSI Gauge Standard Assembly RH Connection with 5000 PSI Gauge Optional Assembly with Left Hand (LH) Nitrogen Bottle Connection. Item 1-10 1-11 1-11 1-11 1-11 1-10L 1-4 6-10 6-10L 1 2 3 4 6* 7 9 9L 10 11 * Part Number 1486750000 1486751000 1486752000 1486753000 1456755000 8700430000 8702780000 1457810000 1457820000 5420920000 0832140000 0873930000 5420860000 0870520000 6661250000 6661260000 6661240000 See Gauges 8702770000 1353290000 Description Standard Assembly with Right Hand (RH) Nitrogen Bottle Connection. PIPE THD. NOTE: Can be used on all diaphragm accumulators with a gas precharge less than 5000 PSI. THD. No Gauge Gauging Assembly (No Hose or Gauge) Hose Assembly with RH Connection Hose Assembly with LH Connection Gas Valve with 1/8" NPT Bleeder Valve Reducer – 1/4 x 1/8 Swivel Connector with Female Thread Connection Charging Hose Nitrogen Bottle Nut with RH Connection (Cga584) Nitrogen Bottle Nut with LH Connection (Dga 584) Nitrogen Bottle Nipple 2. PIPE THD. 1/4” FEMALE EXT. THD.305–32 EXT. For continuous monitoring. Consult factory for further information. 1/8” EXT. Catalog HY10-1630/US Gauging, Unloading Valves Hydraulic Accumulators Accumulator Accessories Gauging Assemblies Gauging Assembly consists of adapter incorporating gas valve, bleeder valve and gas chuck (less gauge). 3000 PSI Part Number (Assembly only) 085122 0000 087101 0000 087103 0000 4000/5000 PSI 871372 0000 Piston Styles All — — All Bladder Styles All 1-15 gal. 10-150 CI All Diaphragm Styles w/Cored valve — — — 085122 0000 087103 0000 871372 0000 Gauging Adapters (Fixed Mount) For continuous monitoring of gas precharge. Order gauge separately. Part Number 086213 0000 085057 0000 146897 0003 Description For 10-150 CI Bladder Accumulators (3000 PSI only) – includes gas valve For 1 Gal. and above bladder and all piston accumulators (3000 - 5000 PSI) For conventional top repairable bladder accumulators (2.5 to 15 Gal.) .94 .94 2.38 2.125 1/2-20 Thread 086213 0000 085057 0000 Unloading Valve Unloading valves provide cost effective safety for your hydraulics by relieving hydraulic pressure when the system is de-energized. Valves conform to OSHA Rule 29CFR1910.147 to enhance safe system operation. Needle valve allows for manual accumulator bleed-down. Features • Lightweight aluminum housing • 2-way normally open solenoid • 3000 PSI operating pressure • Encapsulated 17W Solenoid • Four standard voltage and connection options • Viton seals standard • Small compact manifold design • Leakproof SAE ports standard • Needle valve override • 10 GPM flow rate @ 3000 PSI • 8 GPM @ 2000 PSI average How to Order Unloading Valves DV Series unloading valves can be specified by using the symbols in the chart below to develop a model number. Select only those symbols that represent the features desired, and place them in the sequence indicated by the example at the top of the chart. Series Size Coil Voltage Coil Connection Ports DV DV Accumulator Unloading Valve 10 A B C D A 120/110 VAC, 60/50 Hz 240/220 VAC, 60/50 Hz 12 VDC 24 VDC D C 1/2 NPTF Conduit Connector with 24" Class H Wires D DIN 43650 (Hirschmann Plug) P SAE 18-0.25 SAE Double Spade (DC Only) W Double Wire 24" Class H (DC Only) C C SAE #8 Accumulator and Tank Ports, SAE #5 Test Port 111 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Accessories Catalog HY10-1630/US Repair Tools and Adapters Accumulator Repair Tools Hydraulic Accumulators Accumulator Accessories Port Adapters 1. Bladder Pull Rods — (Bladder Type Accumulator) Pull rods are available in different lengths for different size accumulators. The pull rods attach to the gas valve of the bladder for ease of assembly into shell during reassembly. 2. Core Tool — The core tool is used to remove and reinstall the valve core. It is also used to ream valve seat and repair threads. 3. Spanner Wrench — Fits all standard size bladder accumulators. Used to remove hydraulic poppet assembly from accumulator shell. SAE to SAE Port Adapters Part Number 5626840000 5626850000 5626860000 5626870000 5626880000 5626890000 0864730000 5626900000 5626910000 Description #24 SAE to #20 SAE #24 SAE to #16 SAE #24 SAE to #12 SAE #20 SAE to #16 SAE #20 SAE to #12 SAE #20 SAE to #10 SAE #16 SAE to #12 SAE #12 SAE to #10 SAE #12 SAE to #8 SAE #32 SAE to #24 SA #32 SAE to #20 SAE #32 SAE to #16 SAE Description Pull Rod (1 Qt.-2 / 2 Gal.) Pull Rod (5 Gal.) Pull Rod (10-11 Gal.) Pull Rod (15 Gal.) Core Repair Tool Core Installation Tool Spanner Wrench 1 Part No 085109 0250 085109 0500 085109 1000 085109 1500 582441 0000 300987 085110 0000 5720860000 5720870000 5720880000 SAE to NPT Port Adapters Part Number 5626810000 5626820000 5626830000 5720890000 6560070001 6560070002 Description #24 SAE to 1-1/2" NPT #20 SAE to 1-1/4" NPT #12 SAE to 3/4" NPT #32 SAE to 2" NPT #12 SAE to 1/2" NPT #20 SAE to 1" NPT 112 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Mounting Accessories Hydraulic Accumulators Accumulator Accessories “U” Bolts for Piston & Bladder-Type Accumulators Accumulator Models (3000 PSI) Part No. and Dimensions Piston Bore A2 A3 — A4 — A6 A7 — A9 A12 — Bladder Size — 1 Pint 1 Qt. — 1 Gal. — — 21 /2 - 15 Gal. — — *21/2 - 15 Gal. “U” Bolt Part No. 0854370000 0862090000 0854380000 0864960000 0854390000 0864970000 0854400000 0853360000 0854410000 0854420000 0865020000 A 1/4 1/2 1/2 1/2 5/8 5/8 5/8 5/8 3/4 7/8 5/8 B 2-7/16 3-11/16 4-5/8 5 6-3/4 7-1/8 8-1/4 9 11-1/4 14-1/8 9-3/4 C 2-11/16 4-1/16 5-1/8 5-1/2 7-3/8 7-3/4 8-7/8 9-5/8 12 15 10-3/8 D 2-11/16 3-5/8 4-1/2 4-1/2 6-1/8 6-1/8 7 7-1/8 9-1/2 10-1/4 7-1/4 E 1-3/4 2 3 3 3-3/4 3-3/4 3-3/4 3-3/4 4-1/2 4-1/4 3-13/4 Thd. 1/4-20 3/8-16 1/2-13 1/2-13 5/8-11 5/8-11 5/8-11 5/8-11 3/4-10 7/8-9 5/8-11 Wt. Lbs. 0.2 0.9 1.2 1.3 2.4 2.5 3.0 3.0 6.0 8.2 3.5 Bladder-Type Accumulator Bladder-type accumulators should be mounted vertically with the hydraulic port down. CAUTION: Bladder-type accumulators should never be mounted more than 25° angle from the vertical. "U" Bolt E D NOTE: “U” Bolts should never be mounted more than 1 inch from end of accumulator (piston type). B C Base Bracket Rubber Ring A Piston Accumulator or Gas Bottle Welded Lug (2 places) Straps should be tight on the shell when using a bladder-type accumulator. 1 inch max. 1 inch max. "U" Bolt (2 places) C B D E A Mounting Holes (2 places) "U" Bolt Nuts included on all "U" Bolts. Mounting Plate Base Bracket Assembly for Bladder Accumulators Accumulator Models Bladder Size 1 Gal. (3K) 21/2 -15 Gal. (3K) 25-40 Gal. (3K) 2 /2 -15 Gal. (5K) 1 Part Number and Dimensions Base Bracket Assembly Part No. 1449100000 1448720000 1480020000 1481410000 A 10.3 10.3 15.3 10.3 B C D 4.75 6.75 8.18 6.75 E 8.87 8.87 15.3 8.87 F G H Wt. Lbs. 5 5 10 5 D E 7.87 3.62 7.87 4.84 10.6 7.68 7.87 5.35 3.85 1.58 0.65 x .87 3.85 1.58 0.65 x .87 9.40 4.18 0.87 x 1.06 3.85 1.58 0.65 x .87 C F B A G H 113 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Clamp Brackets Hydraulic Accumulators Accumulator Accessories Clamp Brackets for Bladder-Type Accumulators Dimensions D E Max. 6.3 8.5 11.7 12.0 2.6 3.6 4.8 5.4 Bladder Size 1 Qt., 150 C.I. (Figure A) 1 Gal. (Figure A) 21/2 -15 Gal. (3K) (Figure B) 21/2 -15 Gal. (5K) (Figure B) Clamp Part No. 1466230000 1449080000 1449070000 1349200000 A 4.5 6.8 9.0 9.5 B 3.9 6.3 8.5 8.5 C Max. 5.5 7.6 10.0 10.5 F .35 x .51 .35 x .51 .50 x .75 .50 x .75 G 1.2 1.2 1.2 1.2 Wt. Lbs. 1.8 2.7 4.2 4.5 D G D A E A E B C F B C F Figure A Figure B Clamp Brackets for Diaphragm and Small Piston and Bladder Accumulators Part No. 8700110238 8700110252 8700110291 8700110358 8700110413 8700110476 8700110535 8700110630 1449080000 A B Dimensions C D H Diaphragm liters/cu in — 0.075 / 5 0.16 / 10 0.35 / 20 0.50 / 30 0.75 / 45 1.0 / 60 1.4 / 85 & 2.0 / 120 2.8 / 170 Accumulator Style/Size Piston Bladder bore/series liters/cu in 2" / 4-5K — 3" / 3-4K 3" / 5K 4" / 3K — — — — — 0.50 / 30 1-3 / 60-150 — — — .13 Typ. H B A .37 x .5 (2) Rubber Sleeve 4.25 3.35 4.84 2.81 / 3.01 1.86 5.00 3.94 5.62 3.50 / 3.62 2.28 5.25 4.33 6.06 4.04 / 4.22 2.45 5.25 4.33 6.71 4.67 / 4.90 2.77 5.75 4.92 7.43 5.32 / 5.50 3.21 7.00 5.98 8.29 6.25 / 6.37 3.57 7.60 6.30 8.50 6.80 3.60 — Width 1.25" Clamp Brackets for Series 4000 & Series 5000 Piston Accumulators Piston Bore Size 2” 3” 4” 6” 7” 9” Series 4000 Part Number 8700110252 8700110358 8700110535 — N/A N/A Series 5000 Part Number 8700110252 8700110413 87001100535 — 8701960890 8701961220 114 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA C Ref. 4.25 3.35 4.42 2.62 / 2.82 1.64 D .2 4 4.25 3.35 4.29 2.25 / 2.41 1.58 2" / 3K 0.16 / 10 KleenVent KV Series Hydraulic Reservoir Isolators BLADDER PRODUCTS KleenVent Hydraulic Reservoir Isolators Feature: • Capacities from 2-1/2 to 80 Gallons • Four Bladder Polymers for a Wide Range of Fluids and Temperatures • Fiberglas and Steel Shells • Optional Pressure/Vacuum Breaker 115 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA Kleen Vent . Illinois USA . and water vapor – into your hydraulic system though the reservoirs breather-vent. See chart below or consult factory. Pressure Ratings – Atmospheric pressure. Why Use KleenVent Reservoir Isolators? • • • • • • reduce hydraulic system maintenance costs reduce hydraulic system downtime reduce waste disposal costs extends filter life low maintenance solution range of compounds for a variety of fluids ATMOSPHERIC PRESSURE RESERVOIR HIGH LEVEL Greer KleenVent Reservoir Isolators – The Right Choice For . the changes in gas volume in a hydraulic system’s reservoir can be trapped and prevented from mixing with the outside atmosphere. see next page. EPR. . KleenVent reservoir isolators provide a positive separation without the possibility of clogging or need for maintenance. Seal Code 01 06 28 08 Polymer Buna-Nitrile Butyl Fluorocarbon Elastomer Ethylene Propylene Recommended Operating Temperature Range -20°F to 200°F -29°C to 93°C -40°F to 200°F -40°C to 93°C -10°F to 250°F -23°C to 121°C -40°F to 200°F -40°C to 93°C Maximum Temperature with Reduced Life 225°F 107°C 300°F 149°C 400°F 204°C 300°F 149°C General Application & Compatibility Greer's Standard Compound – Compatible with most mineral oil based fluids Compatible with most phosphate ester fluids and some synthetic fluids Compatible with most mineral oil based fluids at higher temperatures and some exotic fluids Compatible with some synthetic fluids and water 116 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. KleenVent reservoir isolators provide protection against the ingestion of airborne contaminants – dust. Fluids – Greer’s KleenVent reservoir isolators are compatible with virtually any industrial fluid with the proper bladder selection. By using an elastomer bladder as a lung.Catalog HY10-1630-9/US Introduction & Specifications Hydraulic Reservoir Isolators KleenVent KV Series Fluid contamination can lead to high maintenance costs and downtime in hydraulic systems. chemicals. Butyl. And unlike conventional breathervent filters. Options – Pressure/Vacuum Breakers for safety and reservoir protection. • • • • • • Steel/Primary Metal Mills Foundries Pulp and Paper Mills Power Generation Plants Automotive Plants Any Highly Contaminated or Humid Environment ATMOSPHERIC PRESSURE RESERVOIR HIGH LOW LEVEL RESERVOIR LEVEL Specifications Materials • Shell – fiberglas or steel • Ports – steel • Bladders – choice of four compounds – Nitrile. . or Fluorocarbon. see chart below. 5 (9.00 PN1486680000 3.8) 20 (75.4) 22 (10) 38 (17) 60 (27) 80 (36) 115 (52) 150 (68) 190 (86) Optional Pressure/Vacuum Breaker Greer recommends that every KleenVent installation be equipped with a Pressure/Vacuum Breaker to protect the reservoir in the event of a sudden fluid loss or over-filling. replaceable filter cartridge.28 (12.12 (1527) B in.0 Type 2 – Bayonet Style 117 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Dimensions & Options Hydraulic Reservoir Isolators KleenVent KV Series Models.9) 10 (37. Greer offers two types of optional pressure/vacuum breakers.035 bar) • Fixed vacuum relief – 0.50 (1206) 60.6 (929) 49.78 2.12 SAE #16 1-5/16 .12 SAE #24 1-7/8 .01 bar) • 10 micron filter – Type 1.12 SAE #24 1-7/8 .18 (1376) 35. PN1486670000 2.1) 32 (121) 54 (204) 68 (257) Shell Material Fiberglas Fiberglas Fiberglas Fiberglas Steel Steel Steel Steel A in. (mm) 19. reusable sintered bronze.07 bar ± 0.01 bar ± 0.12 SAE #16 1-5/16 .00 (889) 47.15 psi (0.12 Weight lbs.77 1/2" NPT NPT Type 1 – NPT Style 2.25 3.8 (71.0) 18.25 (210 8.8 (1264) 54.6) 40 (151) 60 (227) 80 (302) Actual Capacity Gallons (Liters) 3.6 (78.8 (502) 36. Capacities and Dimensions C B C B A A Steel KleenVent Fiberglas KleenVent Model KV02F0T01A1 KV05F0T01A1 KV10F0T01A1 KV20F0T01A1 KV20M0T01A1 KV40M0T01A1 KV60M0T01A1 KV80M0T01A1 Nominal Capacity Gallons (Liters) 2.2 (1249) 49.Catalog HY10-1630-9/US Capacities.25 (210) 9.6) 20 (75.7) 20.12 SAE #24 1-7/8 .25 (235) 12 (305) 12 (305) 22 (562) 22 (562) 22 (562) C Port Size Thread Size SAE #16 1-5/16 .12 SAE #24 1-7/8 .12 SAE #24 1-7/8 .04 3.5) 5 (18.4) 6.62 Kleen Vent . Illinois USA 4. and Type 2 bayonet style that installs into your existing reservoirs fill-vent port.8 (44.5 psi (0.6 (25.82 4. (mm) 8. Type 1 that installs with a 1/2" male NPT.0) 11. (Kg) 14 (6.15 psid ± 0. Type 2. Features & Specifications: • Fixed pressure relief – 1 psid ± 0. contaminating existing fluids or losing time. This will allow the bladder to deflate as the reservoir level drops. . purging the reservoir. M Steel (20 . Multiple KleenVents should be Hydraulic Reservoir Isolators KleenVent KV Series installed in parallel when the required size exceeds 80 gallons. Illinois USA .80 gal. sum all single acting cylinder “differential” volumes (rod area x stroke) and all accumulator volumes in the system. Multiply the difference in fluid levels by the width and length of the reservoir to calculate the total fluid volume change. Installation Kits . NEW! KleenVent Installation Kits Part Number 8708690006 8708690009 8708690012 8708690018 8708690024 Description Installation Kit with 6' hose Installation Kit with 9' hose Installation Kit with 12' hose Installation Kit with 18' hose Installation Kit with 24' hose How to Order KleenVents KV Series KleenVents can be specified by using the symbols in the chart below to develop a model number. . Select a KleenVent(s) with an actual capacity equal to or greater than the sum calculated. Multiply this sum by 1.2 to find the KleenVent volume required. Sizing a KleenVent on New and Existing Systems On new systems. and place them in the sequence indicated by the example at the top of the chart. Select a KleenVent(s) with an actual capacity equal to or greater than the sum calculated. KleenVents should be installed in a vertical position for optimum performance.) 0 T T SAE 01 A A Standard X Special 1 02 05 10 20 40 60 80 2½ gallon 5 gallon 10 gallon 20 gallon 40 gallon 60 gallon 80 gallon 0 Atmospheric 01 06 08 28 Buna-Nitrile Butyl EPR Fluorocarbon 1 Standard * Special Design No. calculate the total change in fluid volume in the system during operation by measuring the high and low fluid level of the reservoir. On existing systems. Add Without Interruption Add closed-loop protection without shutting down. Select only those symbols that represent the features desired. the above method may be used. Always use “actual volumes” when sizing and select the next higher size when a capacity is required between size offerings.20 gal.Catalog HY10-1630/US Sizing & Ordering Information KleenVent Installation & Sizing Information KleenVents should be installed when the reservoir is at its highest level. if the cylinder and accumulator sizes are known. Series Size Construction Pressure Port Bladder Variation Code KV KV KleenVent 20 M F Fiberglas (2½ . If not. Assigned 118 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 50 (216) 2.00 (229) 119 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 2-1/2 gal.7) 46 (21) 125 (57) 155 (70) 7. Capacities and Dimensions Size 1 quart 1 gal.16 (309) 18.25 (286) 15.9) A B C in (mm) 12.23 (666) 38. Max. 304 stainless steel Poppet & Spring – 304 stainless steel • Gas Valve Cartridge – steel • Gas Valve Protector – steel • Gas Valve Stem – steel • Bladders – Various polymers. Fluid traveling through the hydraulic line bends around the baffle.56 (471) 26.00 (51) 4. Illinois USA .98) 226 (3.3000 PSI (207 Bar) Materials • Shell – high strength alloy steel (SA372.0 190.Catalog HY10-1630/US Specifications and Dimensions There have been many attempts to solve the problems caused by high transient flow conditions inherent with pulsations and shocks.75 (171) 6.69 (983) D E F Port (thread) 1" NPTF 1¼" NPTF 2" NPTF 2" NPTF Weight lbs.03 (77) 5. working pressure/ precharge pressure) 4-1 Pulse-Tone Flow Rates Size (cu in) 1 quart 1 gal.50 (216) 8. Pulse-Tone puts a flow diversion baffle into the line. 703040 703047 703054 703061 Capacity cu in (liters) 60 (0. 1 gallon & up comply with all ASME material specifications as std.38 (187) 11.50 (114) 6.0 LPM 106 145 720 Models. but pulsation and shock energy waves take the path of least resistance right into the nitrogen precharged bladder.75 (171) 4. Maximum Compression Ratio (max. Bladder Material (Code) Nitrile (-1) Nitrile (-1) Nitrile (-1) Nitrile (-1) Part No. 834340 810381 810829 800290 Repair Kit Part No. low lubricity fluids C F PORT B F PORT D Specifications Maximum Operating Pressure . Then came Greer’s Pulse-Tone concept.94 (710) 3.5-15 gal. The trouble with the previous devices was that most of the pulsations and shocks never got near the shock absorber. 5 gal. (kg.) • Ports – all oil service ports.0 38.50 (114) 6. Recommended Flow GPM 28. see Standard and Optional Bladders in Bladder Accumulators section. a patented breakthrough in pulsation control. Pulse-Tones 3000 PSI E A Why Use Pulse-Tones? • • • • • improves system efficiency absorbs hydraulic shocks very contamination tolerant very quick response works well with water.50 (394) 27. The bladder absorbs up to 98% of the waves’ potentially destructive force. 3000 PSI.81 (173) 9.06 (129) 8. All attempts have had one thing in common: they never quite solved the problem.10) 1095 (17.70) 555 (9. 2.) 17 (7. high strength alloy steel – water and chemical service.00 (229) 9. SurgeKushons BLADDER PRODUCTS • General Oil Service • Water & Chemical Service • Slurry Service • Fire Protection Service Greer SurgeKushons Feature: • Operating Pressures to 500 PSI • Eight Different Capacities – from 2 1/2 to 120 gallons • The Highest Quality In-House Manufactured Bladders • ASME Certification Standard – FM and UL Approved Available • Chemical and Water Service Optional • Four Bladder Compounds to Suit a Variety of Fluids and Temperatures 121 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . and chemical and process plants. shocks are experienced when valves open or close or when pumps are started or shut down. water handling systems. SurgeKushons are essentially low pressure bladder accumulators designed to take these shocks out of high flow fluid handling systems. Photo 19 Fuel loading absorbs shock from pump startup and stopping Protecting sensitive meters and small diameter piping from valve closure on fueling trucks Protection from large valve closure shocks 122 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . Applications for SurgeKushons include water sprinkling systems.Catalog HY10-1630/US Applications SurgeKushons Introduction In high volume fluid handling systems. refueling systems. Catalog HY10-1630/US Applications SurgeKushons Introduction Refineries — Shock from pump starting and stopping Liquid bulk handling absorbs surges and shocks from fluids in motion Aircraft protection from valve closure shocks. Illinois USA . 123 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. see Standard and Optional Bladders in this section. petro-chemical plants. SurgeKushon Protection Pays. Capacities and Dimensions” pages for rated pressures. The broad SurgeKushon offering includes: • • • • • 275 & 500 PSI Rated General Service 275 & 500 PSI Rated Slurry Service 275 & 400 PSI Rated FM Approved Fire Service Water & Chemical Service Option Stainless Steel Construction Available . Bladders compatible with most industrial fluids can be furnished on special orders with temperature ranges from -60°F to 400°F (-53°C to 204°C). Airport refueling facilities. Fluids – SurgeKushons are compatible with a wide variety of fluids. Also. Available Options – options available on SurgeKushons include: • Bladder Compounds (see Standard and Optional Bladders in this section) • Water & Chemical Service (see Water & Chemical Service Option in this section) Certifications – ASME (Section VIII. This shock can burst pipes. Precharge – Units are shipped with a 25 psi nitrogen precharge as standard. Greer’s SurgeKushons are accumulators designed to protect fluid handling systems from surge and water hammer damage by absorbing the kinetic energy before it can cause serious damage. shatter or loosen fittings. For other precharge pressures.Catalog HY10-1630/US Specifications When a valve in a high volume fluid handling system opens or closes or a pump starts or starts. bulk handling systems.Consult Factory Virtually all of the components used in the construction of the SurgeKushons including the shells and the bladders themselves. Div. The standard accumulator may be used with petroleumbased industrial or water-based flame resistant fluids. Recommended Flow* GPM LPM 350 1325 400 1514 1000 3785 1400 5300 *Note: with fliud viscosity of 60-70 SSU 124 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. are manufactured inhouse. there can be pressure spikes generated that are four times greater than the system’s design pressure. SurgeKushons Introduction Greer SurgeKushons… Your #1 Choice for Surge Protection! Greer SurgeKushons are made by the leading manufacturer of bladder accumulators in North America. disable pumps and knock out instrumentation. Pressure Ratings – SurgeKushons are available in a variety of maximum operating pressures up to 500 PSI. specify at the time of order. the heart of any SurgeKushon. • control surges and water hammer • help save lives and property • get immediate pay-back from reduced maintenance and damage • save pump energy by continually holding pressure • get longer life from equipment • overall. See “Models.. Fire protection systems using sprinklers should be secured with SurgeKushons. the whole system works better Specifications Materials • Shell – carbon steel to ASME material specifications • Screens – stainless steel • Flanges – carbon steel forgings to ASME material specification • Gas Valve Protector – steel • Gas Valve Stem – steel • Bladders – various polymers.. Maximum Flow Rates Flange Size 3” 3” Slurry 4” & 6” 8” & 10” Max. All processes are internally controlled to the highest standards of quality and consistency... Underground or overhead water or fluid systems can be made safer and more trouble-free with the proper SurgeKushon applications. Illinois USA .all at minimum 4 to 1 design factors. we offer application assistance and will help to design the proper SurgeKushon arrangement to fit your systems requirements including sizing and placement. 1) is available as standard on SurgeKushons with FM Approved and UL Listed as available options. and refineries cannot afford surge-ruptured lines and the accompanying spills. 6 Top Repairable 25 gallon and larger units are supplied as top repairable. Bladders are offered in four different standard compounds to suit a variety of fluids and operating temperatures. 7 Gas Valve All accumulators are fitted with a gas valve for ease of gas precharging. Special compounds are available for unusual or severe applications. Also. SurgeKushon shells meet ASME material specifications as standard. Sizes range from 3” thru 10” with special sizes available (consult factory). 3 Bladder Stems All SurgeKushons are fitted as standard with two-piece bladder stems with replaceable gas valve cartridge for ease of serviceability. saving time and money. and critical seam assembly and curing processes. 125 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. bladders are manufactured in-house to control the material blending. 150 and 300 lb. The top repairable design permits easy checking and maintenance of the bladder without removing the accumulator from the service line. 2 Bladder The heart and soul of a SurgeKushon. It is widely accepted that Greer bladders are the highest quality bladders in the industry.. Illinois USA . Spec MS288892).Catalog HY10-1630/US Design Features & Benefits SurgeKushons Introduction 7 6 3 1 2 5 4 1 Shell SurgeKushon shells are fabricated from carbon steel with minimum 4 to 1 design factors at normal operating pressures. are supplied as standard. 4 Port Flanges ANSI RF flanges. the two-piece stem will accept high pressure military gas valves and permanent mount gauge adapters. molding. For safety. 5 Screens SurgeKushons are equipped as standard with stainless steel screens to prevent bladder extrusion and for corrosion resistance. the gas valve vents if unscrewed. 2 1/2 thru 10 gallon units are equipped with a cored gas valve cartridge (ISO-4570-8VI) for ease of maintenance. 25 gallon and larger units are equipped with a poppet-type (military) gas valve cartridge (Mil. -08 = EPR. 150# Weight 63 (29) 5 gallon (19 liters) 275 PSI (19 Bar) 29.60 (218) 3”.00 (559) 4”.50 (749) 8.44 (1637) 22.00 (559) 4”. Illinois USA .63 (1286) 8. 300# 1010 (459) 1) Note: Bladder Codes: -01 = Buna-Nitrile.44 (2145) 22. 150#) 137 (62) 25 gallons (95 liters) 500 PSI (34 Bar) 35. Capacities and Dimensions B A ASME Certified General Service SurgeKushons Nominal Size 2-1/2 gallon (9. 300# 320 (145) 40 gallons (151 liters) 500 PSI (34 Bar) 43.00 (559) 4”.Catalog HY10-1630/US General and Slurry Service SurgeKushons Models.5 liters) Bladder Code -01 Slurry -01 -04 -08 -28 -01 Slurry -01 -04 -08 -28 -01 Slurry -01 -04 -08 -28 -01 -04 -08 -28 -01 -04 -08 -28 -01 -04 -08 -28 -01 -04 -08 -28 -01 -04 -08 -28 SurgeKushon Part Repair Number Kit SK02S3FA01A1 703184 SK02A3FA01A1 702634 SK02A3FA04A1 704330 SK02A3FA08A1 702636 SK02A3FA28A1 702635 SK05S3FA01A1 703191 SK05A3FA01A1 702637 SK05A3FA04A1 704331 SK05A3FA08A1 702639 SK05A3FA28A1 702638 SK10S3FB01A1 703198 SK10A3FA01A1 702640 SK10A3FA04A1 704332 SK10A3FA08A1 702642 SK10A3FA28A1 702641 SK25A5PB01A1 702615 SK25A5PB04A1 704333 SK25A5PB08A1 702617 SK25A5PB28A1 702616 SK40A5PB01A1 702621 SK40A5PB04A1 704334 SK40A5PB08A1 702623 SK40A5PB28A1 702622 SK80A5PB01A1 702626 SK80A5PB04A1 704335 SK80A5PB08A1 702627 SK80A5PB28A1 SK100A5PB01A1 702630 SK100A5PB04A1 704336 SK100A5PB08A1 702631 SK100A5PB28A1 SK120A5PB01A1 702643 SK120A5PB04A1 704337 SK120A5PB08A1 702644 SK120A5PB28A1 A Pressure Rating 275 PSI (19 Bar) 19.00 (559) 4”.38 (2575) 22. 300# 660 (300) 100 gallons (379 liters) 500 PSI (34 Bar) 84. -04 = Hydrin. 4”.60 (218) B RF Flange 3”.25 (489) Inch (mm) 8.69 (907) 22. 150# (Slurry. 150# 89 (40) 10 gallon (38 liters) 275 PSI (19 Bar) 50. & -28 = Fluorocarbon) 126 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.60 (218) 3”. 300# 885 (402) 120 gallons (454 liters) 500 PSI (34 Bar) 101.44 (1103) 22.00 (559) 4”. 300# 368 (167) 80 gallons (303 liters) 500 PSI (34 Bar) 64. 00 37.60 (218) ANSI RF Flange Size 3” 275 PSI Rated with 150# Flange Model A WeightModel Number Inch (mm) lbs.63 35.25 66.00 (454 liters) (559) RK #702643 1) Note: RK = Repair Kit SK120W4PB01A1 101.) SK02W3FA01A1 16.25 64.69 (1637) (1695) (1694) 660 678 702 (300) (308) (319) 100 Gallon 22.13 (2145) (2215) (2213) 885 903 927 (402) (410) (421) 120 Gallons 22.69 86.31 101.44 66.75 66. (Kg. Capacities and Dimensions B A Water/Chemical Service SurgeKushons (All Bladders are Code -1 Nitrile) Nominal Size 2-1/2 gallon (9.19 SK100W4PD01A1 87.44 SK100W4PC01A1 87.75 101.Catalog HY10-1630/US Water/Chemical Service SurgeKushons Models.75 90.60 (218) 8.56 35.69 (1103) (1162) (1161) 368 386 410 (167) (175) (186) 80 Gallon 22.38 103.44 45.94 (430) 63 (29) 400 PSI Rated with 300# Flange A Weight Number Inch (mm) lbs.31 84.00 (379 liters) (559) RK #702630 SK100W4PB01A1 84.00 (151 liters) (559) RK #702621 SK40W4PB01A1 SK40W4PC01A1 SK40W4PD01A1 43.25 45.19 103. Illinois USA .5 liters) RK #702634 5 Gallon (19 liters) RK #702637 10 Gallon (38 liters) RK #702640 B Inch mm 8.25 (1286) (903) (907) (953) (954) (1056) (1100) (1103) (1149) (1151) (1252) (1632) (1637) (1683) (1684) (1786) (2154) (2156) (2202) (2203) (2305) (2573) (2575) (2621) (2623) (2724) 137 310 310 319 335 347 358 358 367 383 395 650 650 659 675 687 875 875 884 900 912 1000 1000 1009 1025 1037 (62) (141) (141) (145) (152) (158) (163) (163) (167) (174) (180) (295) (295) (300) (307) (312) (398) (398) (402) (409) (415) (455) (455) (459) (466) (471) 25 gallon 22.25 107.56 41.00 (303 liters) (559) RK #702626 SK80W4PB01A1 SK80W4PC01A1 SK80W4PD01A1 64.56 43.69 38.38 (2575) SK120W4PC01A1 103.31 64.60 (218) 8.81 84.63 (2632) 1010 1028 1052 (459) (467) (478) 127 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.88 86.44 45.31 49.50 37.94 (735) 89 (40) 3” 4” 4” 6” 8” 10” 4” 4” 6” 8” 10” 4” 4” 6” 8” 10” 4” 4” 6” 8” 10” 4” 4” 6” 8” 10” SK10W3FA01A1 SK25W3FB01A1 SK25W3FB01A1 SK25W3FC01A1 SK25W3FD01A1 SK25W3FE01A1 SK40W3FB01A1 SK40W3FB01A1 SK40W3FC01A1 SK40W3FD01A1 SK40W3FE01A1 SK80W3FB01A1 SK80W3FB01A1 SK80W3FC01A1 SK80W3FD01A1 SK80W3FE01A1 SK100W3FB01A1 SK100W3FB01A1 SK100W3FC01A1 SK100W3FD01A1 SK100W3FE01A1 SK120W3FB01A1 SK120W3FB01A1 SK120W3FC01A1 SK120W3FD01A1 SK120W3FE01A1 50.94 (907) (965) (964) 320 338 362 (145) (154) (165) 40 gallons 22.69 (2634) SK120W4PD01A1 103.31 70.31 43. (Kg.44 66.69 37.00 (95 liters) (559) RK #702615 SK25W4PB01A1 SK25W4PC01A1 SK25W4PD01A1 35.) 3” SK05W3FA01A1 28.75 45. Special 1 Code 02 05 10 25 40 80 100 120 Size 2½ gal. and place them in the sequence indicated by the example at the top of the chart. Oil Service W Water & Chemical Service S Slurry Service1 1) Note: Includes water service. 150#ANSI RF Flg. Maximum Temperature with Reduced Life 225°F 93°C 200°F 93°C 300°F 149°C 400°F 204°C General Application & Compatibility1 Greer's Standard Compound – Compatible with most mineral oil based fluids. PD 8”. Compatible with some synthetic fluids and water. and the types of fluids that are generally compatible. PC 6”. The following table lists the optional bladders available. PA 3”. Rated Pressure Bladder Material Design Variation Design Code Series Size Construction Port SK SK Series SurgeKushons 10 A A Std. (151 liters) 80 gal. their recommended operating Code 01 04 08 28 Polymer Buna-Nitrile Hydrin (Lo-Temp) Ethylene Propylene Flurocarbon Elastomer Recommended Operating* Temperature Range -20°F to 165°F -10°C to 80°C -40°F to 160°F -40°C to 71°C -40°F to 200°F -40°C to 93°C -10°F to 250°F -23°C to 121°C temperature ranges. Select only those symbols that represent the features desired. FE 10”. FD 8”. For water or corrosive fluid service.Catalog HY10-1630/US SurgeKushons Options & Ordering Information Standard and Optional Bladders A variety of bladders are offered to suit a wide range of fluids and operating temperatures. Illinois USA . 150#ANSI RF Flg. How to Order SurgeKushons SurgeKushons can be specified by using the symbols in the chart below to develop a model number. (454 liters) 2 3 4 5 Rated Pressure 200 PSI (14 Bar) 275 PSI (19. please consult the factory. Bladder Kits A full range of genuine Greer replacement bladder kits are available to bring your SurgeKushon back to original condition should replacement become necessary. Temperature ranges may vary depending upon the fluid used in the hydraulic system. 3 FA 01 A S A Standard ASME Cert. Assigned Port Flanges FA 3”. 150#ANSI RF Flg. (379 liters) 120 gal. (303 liters) 100 gal. All bladder kits include port o-ring and back-up seals and gas valves with secondary seals. For the Minimum Design Metal Temperature (MDMT) of ASME certified SurgeKushons. all parts that come into contact with the system fluid are made from stainless steel or have a Skotchkote 134® coating. (19 liters) 10 gal. With this corrosive resistant option. (Consult factory for SurgeKushon repair kit numbers). 150#ANSI RF Flg. * The temperatures listed indicate the operating temperature range of the seals. 300#ANSI RF Flg. Compatible with most mineral oil based fluids with enhanced low temperature performance. (38 liters) 25gal. 300#ANSI RF Flg. XX Special 128 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. FC 6”. Water & Chemical Service Option Standard SurgeKushons are manufactured from carbon steel and are intended for oil or non-corrosive fluid service. PB 4”. Compatible with most mineral oil based fluids at higher temperatures and some exotic fluids. 1) Note: Consult your local Greer distributor or the factory for fluid compatibility information.0 Bar) 400 PSI (28 Bar) 500 PSI (35 Bar) 01 04 08 28 Buna-Nitrile Hydrin EPR Fluorocarbon 1 Standard * Special Design No. 300#ANSI RF Flg. not the SurgeKushon. 300#ANSI RF Flg. (9 1/2 liters) 5 gal. FB 4”. (95 liters) 40 gal. the Water & Chemical Service option should be specified. 150#ANSI RF Flg. Sizing and Selection • Piston Accumulators • Bladder Accumulators • KleenVent Click Here to Access inPHorm ONLINE Accumulator Sizing For: • Shock Suppression • Thermal Expansion • Pulsation Dampening • Auxiliary Power Source 129 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . Auxiliary Power Source Vw V1 = 1 P3 /f P1 1 P3 /n P2 0. In3 Nitrogen gas constant-charging of Accumulators (see charts on pages 134-135) Nitrogen gas constant-discharging of Accumulators (see charts on pages 134-135) Note: Gas Precharge usually 100 psi below minimum pressure for Piston Accumulators*. For further engineering assistance. contact Parker’s Accumulator Technical Support Group at (815) 636-4100. Gas precharge is 90% of minimum pressure for Bladder Accumulators. For manual sizing calculations. *90% where minimum system pressure is less than 1000 psi.Catalog HY10-1630/US Sizing and Selection Sizing and Selection Software Parker offers leading edge application assistance. 130 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. TM Hydraulic Accumulators Piston and Bladder Type Accumulator Sizing for: • • • • Shock Suppression Thermal Expansion Pulsation Dampening Auxiliary Power Source Calculations for accumulator sizing take into consideration the charge and discharge rate of the accumulator. In3 Required Accumulator volume. Illinois USA .95 1 – Where: P2 P3 P1 VW V1 f n = = = = = = = Maximum operating pressure in PSIA Minimum operating pressure in PSIA Pre-charge pressure required in PSIA Volume of fluid collected or discharged by accumulator. see below and on the following pages. in the form of the Accumulator Sizing and Selection Software (see page 16). 33 x 10-6 Cast Iron: 6. Illinois USA .155) –1 Where: W V n P2 Pm V1 P1 G Q = weight of fluid (lbs) = fluid velocity (ft/sec) = Discharge coefficient (see charts on pages 134-135) = = = = = = system pressure Shock pressure accumulator size required pre-charge pressure force of gravity flow rate in GPM Thermal Expansion V1 = P  Va (T2 − T1 )(β − 3α ) 2   P1  P  1−  2   P3  1 n 1 n Where: α β n P1 P2 P3 V1 Va T1 T2 = = = = = = = = = = Coefficient of Linear Expansion of Pipe Material per °F Coefficient of Cubical Expansion of Fluid per °F Discharge Coefficient (see charts on pages 134-135) Precharge Minimum System Pressure @ T1 (PSIA) Maximum System Pressure @ T2 (PSIA) Accumulator Size Fluid Volume Subject to Thermal Expansion Initial Temperature (Lower Temp °Kelvin) Final Temperature (Higher Temp °Kelvin) Coefficient of Linear Expansion of Pipe Material per °F Steel: 6.60 x 10-4 131 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.55 x 10-6 Aluminum: 10 x 10-6 Coefficient of Cubical Expansion of Fluid per °F Water: Oil: 1.15 x 10-4 4.Catalog HY10-1630/US Sizing and Selection Hydraulic line shock suppression 1 P2 / n (12W) (V ) (n-1) P1 2 Hydraulic Accumulators Piston and Bladder Type V1 = + (Q 2 (g) (P2) Pm P2 (n-1) /n * 1. 132 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. In3 Required Accumulator volume.15 . Calculations for accumulator sizing takes into consideration the charge and discharge rate of the accumulator.06 .25 .13 .25 . In3 Nitrogen gas constant-charging of Accumulators (see charts on pages 134-135) Nitrogen gas constant-discharging of Accumulators (see charts on pages 134-135) Note: Gas Precharge usually 100 psi below minimum pressure for Piston Accumulators.06 .06 .Catalog HY10-1630/US Sizing and Selection Hydraulic Accumulators Piston and Bladder Type Piston pump pulsation dampening ALK V1 = 1– P2 P1 1 /n 1 P 2 /n P3 Where: K = Pump output coefficient n = Coefficient of discharge (see charts on pages 134-135) P1 P2 P3 A L V1 = = = = = = Nitrogen gas pre-charge System operating pressure Maximum allowable shock pressure Piston area Piston stroke Accumulator size required Pump output coefficient is calculated depending on single acting or double acting pump: Simplex single Simplex double Duplex single Duplex double Triplex single Triplex double Quadruplex single Quadruplex double Quintiplex single Quintiplex double . Illinois USA .60 .02 Existing accumulator output used in an auxiliary power source application. Gas precharge is 90% of minimum pressure for Bladder Accumulators.95 V1 1 – Vw = 1 P 3 /n P2 1 P3 /f P1 Where: P2 P3 P1 VW V1 f n = = = = = = = Maximum operating pressure in PSIA Minimum operating pressure in PSIA Pre-charge pressure required in PSIA Volume of fluid collected or discharged by accumulator. 0.10 . 12 1.33 1.16 1.02 1. the expected operating temperature is 130°F.94 .97 .05 1.88 150.78 .00 .95 .82 .74 .80 .98 .00 .12 1.94 .03 1.92 .82 .91 .12 1.02 1.28 1.15 1.10 1.22 1.72 40.93 .06 1.75 .13 1.90 .08 1.00 .84 .Catalog HY10-1630/US Sizing and Selection Hydraulic Accumulators Piston and Bladder Type Temperature Variation Temperature variation can seriously affect the precharge pressure of an accumulator.97 210.02 1.18 1.83 .89 .94 .91 .29 1. 1.16 1. In order to assure the accuracy of your accumulator precharge pressure.95 .88 .06 1.82 . 210. 1.03 1.22 1.73 .16 1.06 1.00 .92 . Extend lines from each value until they intersect to find the temperature variation factor.90. 90.08 1.04 1. in this case.02 1.77 .17 1.19 1.07 1.13 1.80 .07 1.98 .16 1. 170.28 1.18 1. 0. 140.05 1.11 1.98 .95 . you need to factor in the temperature variation.18 1.05 1.04 1.21 1.95 .92 .98 .17 1. 1.25 1.98 .92 .10 1.03 1.94 .08 1.11 1. The temperature variation factor is determined by the temperature encountered during precharge versus the operating temperature expected in the system.03 1.10 1.25 1.94 .02 1. As the temperature increases.26 1.77 .19 1. 1.99 . 80.05 1.00 .74 50.08 1.91 .02 1.00 .90 .78 .93 .79 .90 .85 . 30.97 .87 140.04 1.00 .88 .79 .23 1.85 .90 . 1.07 1.85 130.87 .93 .84 .92 .88 .89 .86 .94 190.08 1.94 .19 1.88 .18 1.09 1.23 1.88 .76 70.83 .80 .97 .85 .04 1.22 1. 1.95 .10 1.98 .11 1.92 .93 .82 .19 1.03 1.14 1.30 1.03 1.81 . 40.92 .00 .77 .90 .89 .85 .09 1.11 1.95 .02 1.86 . 1.87 .14 1.07 1.98 .04 1.98 .04 1.29 1.26 1.75 .03 1. vertical column.89 .97 .00 .94 .24 1.02 1.29 1.20 1. 50.98 .07 1.00 .95 .85 .96 .97 .05 1.88 .93 .02 1.06 1.87 .92 .91 .98 .24 1.95 .31 1.17 1.36 1.90 . 1.11 1.06 1.12 1.20 1.05 1.03 1. 1.16 1.04 1.10 1.87 . 1.08 1.06 1.13 1.00 .13 1.88 .22 1.10 1. 1.08 1.02 1.21 1. 1.93 .84 .99 220.85 .81 100.96 .02 1.02 1.20 1.16 1.96 .96 200.20 1.09 1.00 Let’s assume the temperature during precharge is 70°F.76 . 180. 70.89 .93 180.24 1.91 .12 1.14 1.90 to obtain the actual precharge pressure required – 900 psi. 110. conversely.86 .14 1.78 80.07 1.12 1.02 1.05 1.06 1.93 .18 1.12 1. 120.95 .89 .87 . 200. find the operating temperature of 130°F in the left hand.13 1.91 170.11 1.02 1.20 1.08 1.89 . Next.98 .12 1.95 .81 .10 1.20 1. Multiply the desired precharge of 1000 psi by the temperature variation factor of 0.75 60.25 1.81 .83 .03 1. 220.84 .90 160. 1. 133 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.10 1.82 110.05 1.98 .85 .22 1. Find the charging temperature of 70°F in the top horizontal row. 150.84 .95 .07 1.09 1.00 .08 1.05 1.16 1. 1.91 .98 .82 . 1.97 .04 1.18 1.31 1. Temperature During Precharge 30.96 .01 1.06 1.86 .24 1. 1.80 . the precharge pressure increases.00 . 1.86 .15 1.97 .86 .84 120.92 . 1.05 1.84 .86 .35 1.10 1.91 .83 .15 1.15 1. 1.05 1.83 . 190.13 1.95 . Illinois USA .78 .98 .21 1.07 1.79 .94 .24 1. and your desired precharge is 1000 psi.88 .25 1.97 .98 .02 1.34 1.02 1. 100.97 .98 .78 .91 . decreasing temperature will decrease the precharge pressure. 1.79 90.08 1.76 .93 .17 1.27 1. 130.88 .27 1.00 .27 1.15 1.97 .04 1.37 1.33 1.32 1.09 1.79 .31 1.00 .06 1.09 1.90 .89 .89 .93 .96 .02 1.96 .00 .00 .98 . 60.39 1.00 .14 1.82 .00 .94 . 160.14 1.81 .83 .94 .14 1.91 .92 .02 1. Catalog HY10-1630/US Sizing and Selection Hydraulic Accumulators Piston and Bladder Type Selection Chart for Charge Coefficient “f” & Discharge Coefficient “n” Chart No.60 Seconds 61 . 1 0 .120 Seconds n&f Pressure (PSI) Pressure (PSI) 134 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.30 Seconds n&f Pressure (PSI) Pressure (PSI) 31 . Illinois USA .8 Seconds 9 . 1 121-500 Seconds 501-900 Seconds n&f Pressure (PSI) Pressure (PSI) Instructions for selection of Charge Coefficient “f” & Discharge Coefficient “n” 1. Select the graph which corresponds to the time (seconds) required to charge (discharge) the accumulator with fluid.) 6. Determine the time required in seconds to charge the accumulator with fluid. Move vertically along this column until you intersect the line corresponding to the gas temperature. “n” = Discharge Coefficient. “f” = Charge Coefficient. Determine Average System Pressure. 3. Then move horizontally along this line. Determine the time in seconds to discharge the oil from the accumulator. read the charge coefficient “f” on the left side of the graph. locate the average system pressure along the bottom portion of the graph. 4. assume 100°F. 7. Repeat for the discharge coefficient “n” starting with Step #4. 135 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 2. To use the graph. (If gas temperature under operating conditions is not known. 5.Catalog HY10-1630/US Sizing and Selection Hydraulic Accumulators Piston and Bladder Type Selection Chart for Charge Coefficient “f” & Discharge Coefficient “n” Chart No. Select the curve on the graph which corresponds to the gas operating temperature. Illinois USA . venting the relief valve and unloading pump/electric motor. an electric pressure switch can be used. the pressure switch sends an electrical signal to the 2way valve solenoid. In the circuit illustrated. Such a valve could be located at this point in the circuit. M M Pressure Switch * Pilot Operated Relief Valve (Simplified Symbol) * Unloading Valve 136 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Using a pressure switch to vent a relief valve results in a pump/electric motor being fully unloaded when system conditions dictate. solenoid operated 2-way valve which vents and de-vents a pilot operated relief valve. Control of Usable Volume The usable volume of an accumulator should be discharged at a controlled rate. In the circuit illustrated. Once the valve closes. However. an accumulator which is used to develop a pressurized flow can discharge its usable volume too rapidly as a downstream directional valve is shifted. For this reason. the pressure switch cuts out the signal. Illinois USA . accumulators in this application are often equipped with a flow control and bypass check at their inlet-outlet port.Catalog HY10-1630/US Applications Hydraulic Accumulators Piston and Bladder Type *Safety Note: In any accumulator circuit. a means should be available of automatically unloading the accumulator when the machine is shut down. * Pump Unloading in Accumulator Circuits To keep a pump/electric motor fully unloaded until it is required to re-charge an accumulator. a pressure switch senses accumulator pressure sending and cutting-out electrical signals at various pressure levels. The setting of the pressure switch determines the pressure range within which a pump/electric motor works. If an accumulator is required to maintain system pressure. an unloading valve is used to dump a flow back to tank once an accumulator is charged to the unloading valve setting. With the accumulator charged. this controlled rate is automatically achieved by the leakage fluid it has to replace. When the accumulator is being charged. pump/electric motor must therefore generate power to recharge the accumulator to the unloading valve setting. The electrical signals are transmitted to a normally-open. Catalog HY10-1630/US Applications Differential Unloading Relief Valve Instead of using a pressure switch and solenoid valve to vent a relief valve while an accumulator is charged, one hydraulic component can be used — a differential unloading relief valve. A differential unloading relief valve is specifically designed for use with accumulators. As its name implies, the valve unloads a pump/electric motor over a differential pressure range. A differential unloading relief valve consists of a pilot operated relief valve, check valve, and differential piston in one valve body. The valve body includes pump, tank, and accumulator passages. Hydraulic Accumulators Piston and Bladder Type * Differential Unloading Relief Valve Differential Piston Pilot Valve Dart Maintaining Pressure Accumulators are used to maintain pressure. This can be required in one leg of a circuit while pump/electric motor is delivering flow to another portion of the system. In the circuit illustrated, two clamp cylinders are required to hold a part in place. As the directional valves are shifted, both cylinders extend the clamp at the pump’s compensator setting. During this time, the accumulator is charged to the setting also. System demands require that cylinder B maintain pressure while cylinder A retracts. As directional valve A is shifted, pressure at the pump, as well as in line A, drops quite low. Pressure at cylinder B is maintained because the accumulator has stored sufficient fluid under pressure to make up for any leakage in line B. Accumulators not only maintain pressure by compensating for pressure loss due to leakage, but they also compensate for pressure increase due to thermal fluid expansion or external mechanical forces acting on a cylinder. In the illustrated circuit, assume that the cylinder is operating near a furnace where ambient temperatures are quite high. This causes the fluid to expand. With an accumulator in the circuit, the excess volume is taken up, keeping the pressure relatively constant. Without an accumulator, pressure in the line would rise uncontrollably and may cause a component housing, fitting, or conductor to crack. The same situation can also occur if an external mechanical force acts to retract the cylinder. Assume now that the cylinder is clamping a curing press. As curing occurs, heat within the press causes it to expand resulting in a force acting to retract the piston rod. The accumulator once again absorbs the additional volume, maintaining the pressure at a relatively constant level. Passage to Accumulator Check Valve Passage From Pump Orifice Main Valve Spool Passage to Tank Valve A Cylinder A M Valve B * Cylinder B Extra Volume Absorbed * Heat Expands Fluid ˚F ˚F Curing Press ˚F ˚F Force To Retract *Safety Note: In any accumulator circuit, a means should be available for automatically unloading the accumulator when the machine is shut down. Such a valve could be located at this point in the circuit. 137 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Applications Hydraulic Accumulators Piston and Bladder Type Developing Flow Since charged accumulators are a source of hydraulic potential energy, stored energy of an accumulator can be used to develop system flow when system demand is greater than pump delivery. For instance, if a machine is designed to cycle infrequently, a small displacement pump can be used to fill an accumulator over a period of time. When the moment arrives for the machine to operate, a directional valve is shifted downstream, and the accumulator delivers the required pressurized flow to an actuator. Using an accumulator in combination with a small pump in this manner conserves peak horsepower. For instead of using a large pump/electric motor to generate a large horsepower all at once, the work can be evenly spread over a time period with a small pump/ electric motor. M * 100 GPM Absorbing Shock Hydro-pneumatic accumulators are sometimes used to absorb system shock even though in this application they are difficult to properly design into a system. Shock in a hydraulic system may be developed from the inertia of a load attached to a cylinder or motor. Or, it may be caused by fluid inertia when system flow is suddenly blocked or changed direction as a directional valve is shifted quickly. An accumulator in the circuit will absorb some of the shock and not allow it to be transmitted fully throughout the system. Shock may also occur in a hydraulic system due to external mechanical forces. In the circuit illustrated, the load attached to the cylinder has a tendency to bounce causing the rod to be pushed in and shock generated. An accumulator positioned in the cylinder line can help reduce the shock effects. Load Bounces * Restriction Controls Accumulator Discharge *Safety Note: In any accumulator circuit, a means should be available for automatically unloading the accumulator when the machine is shut down. Such a valve could be located at this point in the circuit. M * Developing System Flow 138 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Application Data Sheet Hydraulic Accumulators Piston and Bladder Type Contact Information CUSTOMER: ADDRESS: CONTACT: PHONE: FAX: EMAIL: Customer Requirements Quantity/Release: ___________________________ Quantity (Annual): ___________________________ Type (Piston or Bladder): _____________________ Bore Size (piston only): ______________________ Capacity: __________________________________ Working Pressure/Design Factor. _______________ Seal Type/Compound:________________________ Hydraulic Port:______________________________ Gas Port: __________________________________ Operating Temperature Range:_________________ System Fluid: ______________________________ Gas Valve: _________________________________ Precharge:_________________________________ Water Service? ____________________________ Plating/Coating: ____________________________ Material Type: ______________________________ Paint: ____________________________________ Switches: _________________________________ Certification: _______________________________ Special Test? _______________________________ Special Label? _____________________________ Customer Drawing Included? _________________ Customer Part # ___________________________ Envelope Restrictions: _______________________ Application Description/Comments FORM-0117, Rev. 1 Please fill out and fax to 815-636-4113. For assistance, call 815-636-4100. 139 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Notes Hydraulic Accumulators Piston and Bladder Type 140 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Piston Accumulators Hydraulic Accumulators Maintenance Instructions Hydraulic Piston Accumulators Installation All accumulators shipped from the factory will be pre-charged to a nominal pressure in order to seat the piston on the hydraulic cap. which contains a connection to the accumulator should be designed so that it automatically discharges all hydraulic fluid from the accumulator when the equipment is turned off. it should be rigidly mounted using any combination of the mounting holes provided at the hydraulic cap or proper clamps. However. in some cases they will be shipped with a nitrogen charge. The accumulator can be mounted in any orientation. Keep the hydraulic port covered to keep out foreignmaterial until ready to make the hydraulic connections. the value of which will be marked on the label/nameplate. 141 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. In this case the precharge will not be listed on the label. However. The hydraulic circuit. . Illinois USA Maint. 9. standards: Nitrogen gas bottles for water pumped nitrogen has a right-hand valve thread which requires charging and gauging assembly †144595XX00 for units up to 3000 psi. Oil-pumped nitrogen requires a left-handed valve thread (use †144596XX00). (Gas valve cap serves as a secondary seal. as it will dam age the valve core. Make sure nitrogen supply is shut off. (C) Close bleed valve. Check for precharge leak using a common leak reactant. (C. (A) Remove gas valve guard and gas valve cap. Part Number 871372XX00 POINT “D” VALVE CORE POINT “C” ACCUMULATOR FIGURE 5 Part #L07471000* Gas Valve with medium pressure core for 3000 psi service. lb. Hydraulic Accumulators Maintenance Instructions FIGURE 1 PART #144595XX00 FIGURE 2 PART #085122XX00 3000 PSI UNITS Part Number 144595 XX00 (Std) (Right-Hand) Charging and Gauging Assembly for Cored Accumulators Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings adapter incorporating gas valve. bleeder valve and gas chuck (less gauge). For left-hand thread nitrogen bottle fitting. (K) Hold gas valve to keep from turning. Do not turn the "T" handle all the way down. use assembly †144595XX00 (Figure 1). Shut off when gauge indicates desired pre-charge.5-17 cm kg) and valve guard. 142 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. turn “T” handle all the way out on gas chuck (Figure 1). (E) Turn gas chuck “T” handle until the gauge starts showing the pressure in the accumulator.2 cm kg). This will open the poppet inside the gas valve.G. then slowly open bleed valve (Figure 1).5-17 cm kg). If the desired pre-charge is exceeded. Note: Three (3) turns will fully open the valve. (J) For gas valves as shown in Figure 6.Catalog HY10-1630/US Piston Accumulators Pre-Charging Use an inert gas such as nitrogen for pre-charging piston accumulators. close nitrogen bottle valve. bleeder valve and gas chuck (less gauge). bleeder valve and gas chuck (less gauge). then open bleed valve.035-14 NGO female)adapter incorporating gas valve. Part Number 085122XX00 FIGURE 3 PART #870816XX00 5000 PSI UNITS Part Number 870816XX00 FIGURE 4 PART #871372XX00 Charging and Gauging Assembly for 5000 PSI Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings (1. Accumulator having gas valve as per Figure 5. It is strongly recommended that the nitrogen bottle used have the appropriate pressure high pressure regulator (not included). remove assembly. This will allow the gas temperature to stabilize.) † "XX" Denotes to gauge pressure.) (11. bleeder valve and gas chuck (less gauge). Do not use oxygen or shop air. Attach hose to nitrogen bottle. High pressure may rupture rubber valve seat. with a wrench. If equipment other than the above listed is used. attach swivel nut to gas valve and tighten (10-15 in. (L) Replace gas valve cap (10-15 in. use †870816XX00 (See Figure 3).7-9. Nitrogen source and all components must be rated for a pressure at least as high as the nitrogen source. make sure it is compatible with the gas valve assembly. (F) For gas valves as shown in Figure 6. If accumulator has a gas valve as shown in Figure 6.) (11. For all 3000 psi rated accumulators. Do not reduce pre-charge by depressing valve core with a foreign object. If accumulator has a gas valve as shown in Figure 5 follow steps A through L and skip steps F and J. lbs. hold gas valve at point “C” with one (1) wrench while un screwing hex nut at point “D” with a second wrench. oil-pumped nitrogen may be used. (D) Making sure not to loop or twist the hose. lbs. 12 bore and some 5000 psi units. Illinois USA . Gauging Assembly for Cored Accumulators Gauging device consisting of adapter incorporating gas valve. and Part #L07688000* Gas Valve with high pressure core for 5000 psi service. Gauging Assembly for 5000 PSI Gauging device consisting of adapter incorporating gas valve. specify part number 144596XX00. (H) Let the pre-charge set for 10 to 15 minutes. FIGURE 6 Part #L07689000* Gas Valve with poppet for ASME units 7. follow steps A through L and skip steps E and I.) (5.A. (G) Crack open nitrogen bottle valve and slowly fill accumulator. loosen swivel nut. (I) When finished pre-charging accumulator. tighten hex nut at point “D” to close internal poppet (5-8 ft. If water pumped nitrogen is not available. (B) Back gas chuck “T” handle all the way out (counter clockwise) before attaching charging assembly to accumulator gas valve. For accumulators rated over 3000 psi and the precharge requirement is above 2300 psi. (11) Attach swivel nut to gas valve and tighten (10-15 in.2 cm kg) then open bleed valve to relieve residual gas charge in the gauging assembly. Repair and Replacement Minor nicks. state complete model number from nameplate. Remove accumulator from hydraulic system. . Wait until all gas precharge is relieved from the accumulator and then remove gas valve. This will open the poppet inside the gas valve.5-17 cm kg) and valve guard.) (11. scratches or light scoring of the body bore can be removed by using crocus cloth. When ordering repair kits. Accumulators having gas valve as per Figure 5. use assembly as shown in Figure 4 (Part #871247XX00). o-rings and their respective back-up washers if the original assembly contained them. lb. Pre-charge Checking Procedure Using appropriate valve in the hydraulic system. Then remove gauging assembly and gas valve. Clean bore of body with a clean. with cored gas valve. Bore must be clean of any visible particles or particles detectable to touch. using a long bar working against the pins. discharge all oil from accumulator and allow piston to bottom against hydraulic end cap. lb. To remove cap or caps. For accumulators rated for 3000 psi or less. Threaded holes in hydraulic cap may be used as a means of attachment for lifting. remove assembly. tighten hex nut at point “D” to close internal poppet (5-8 ft. For accumulators rated over 3000 psi up to 5000 psi. Examine body bore. Some accumulators may have both end caps threaded into the body and some units may only have the gas cap threaded into the body. (6) To remove gauging assembly turn “T” handle all the way out on gas chuck (Figure 1). use gauging assembly as shown in Figure 2 (Part #085122XX00). or damage. Remove from Hydraulic System Shut equipment down and make certain that hydraulic pressure at the accumulator is at zero. Then. if any. Dress bore until all apparent imperfections have been removed. remove gas valve guard and gas valve cap. NEVER TRY TO REMOVE PISTON BY APPLYING COMPRESSED AIR AT OPPOSITE END. Disassembly of Accumulator Once the gas valve is removed . (8) Replace gas valve cap (10-15 in. attach gauging assembly as shown in Figure 2 following Steps 1 through 5.5-17 cm kg). lb. 143 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.) (11. Hydraulic Accumulators Maintenance Instructions (13) With a wrench.lay the accumulator horizontal and hold down with a strap wrench or in a vise. Replace PTFE wear rings. Then hold valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench. Periodic checking of pre-charge pressure will detect whether V-o-ring wear is sufficient to begin reducing sealing performance.7-9. pre-charge pressure will rise if oil gathers in the gas side and will fall if gas leaks into the oil side or out past gas end seals. then. (10) Close bleed valve. (12) Hold gas valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench. also check for gas valve and/or end seal leakage. unthread the cap from the body.5-17 cm kg). IN BOTH CASES ALWAYS REMOVE THE GAS CAP FIRST (end cap which contained gas valve). Accumulators having gas valve as per Figure 6. Also specify fluid and temperature at which used. from time of its pressure checking. Illinois USA Maint. (3) Close bleed valve. or use a sling around the body. If pre-charge is low. using a light. install three (3) pins into the holes in the cap. For accumulators having gas valve as shown in Figure 5. Inspection Inspect piston for cracks.Catalog HY10-1630/US Piston Accumulators Maintenance Repair Kits (see Parts List) are available for all accumulator models. Replacement of other seals on end caps and gas valve is recommended (see Kit Numbers). Occasional replacement of V-o-ring seal on the piston is generally the only maintenance required. (5) Turn gas chuck “T” handle until the gauge starts showing the pressure in the accumulator. lbs. open bleed valve until all gas precharge is relieved from accumulator. (14) Hold gas valve at point “C” with wrench and remove swivel nut assembly. moving the tool around the piston several times while using the other hand to work ring off the piston. Do not turn the "T" handle all the way down.5-17 cm kg). then open bleed valve to relieve residual gas charge in the gauging assembly. loosen swivel nut.) (11. V-o-rings. lift seal with O-ring pick or similar tool. To remove V-o-ring from piston. Inspect end caps for damaged threads or burrs on o-ring grooves. (2) Back gas chuck “T” handle all the way out (counter clockwise) before attaching charging assembly to accumulator gas valve. for scratches or scoring. Note: Three (3) turns will fully open the valve. Remove o-rings and back-up rings from end cap. (7) Hold gas valve from turning.) (11. lint-free cloth soaked in clean solvent. Allowing for temperature difference.) (5. For accumulators having gas valve as shown in Figure 6. Turn 23 times and read pre-charge. It is suggested that a check be made a week after installation. and thereafter once a month. (4) Attach swivel nut to gas valve and tighten(10-15 in. (9) Remove gas valve guard and gas valve cap. burrs around o-ring grooves. (1) Remove gas valve guard and gas valve cap. as it will damage the valve core. Remove piston by pushing from hydraulic end with a bar. lbs. Cleaning Thoroughly clean metal parts in solvent and dry with compressed air. At this point the piston will be bottomed at the hydraulic end. and install gas valve guard. (15) Replace gas valve cap and tighten (10-15 in. 105 D 2.562 2.0 160+ 10. Illinois USA .030 .124 .4K.030 .500 4.4K. Call the factory for price and delivery. 50+ 5.030 .089 . Care should be exercised not to drag o-ring over threads. Hydraulic Accumulators Maintenance Instructions BORE SIZE 2 3 4 6 7 8 9 12 ASSEMBLY TORQUE Ft.030 G 1. Install new back-up ring first.312 1.500 3.0 390+ 25. It is highly recommended to use a piston starting sleeve for reassembly of piston accumulators.150 12.375 1.0 390+ 25. Insert the piston in the starting sleeve with the dished side of the piston toward the gas end.030 5.0 90+ 7.750 6.001 9.0 390+ 25.030 .000 14.875 H 1.375 3. Lb.0 220+ 15. End cap will stop against chamfer leading into honed bore (all caps must be tightened to proper torque as per following chart).000 4.Catalog HY10-1630/US Piston Accumulators Reassembly Coat all internal parts with clean hydraulic fluid before reassembly.112 5. Starting sleeve dimensions are shown below.500 6.375 1.268 F .002 5.174 .5K 3K 3K 3K 3K 3K 3K BORE SIZE 2 3 4 5 6 7 9 12 144 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.250 11.100 . PARTS LIST PART NUMBER PSD0000002 PSD0000003 PSD0000004 PSD0000005 PSD0000006 PSD0000007 PSD0000009 PSD0000012 A 2. then a new o-ring on threaded end cap or caps and install into body bore.150 9.864 7.876 E .375 C 2.375 2.375 5.030 . Insert the starting sleeve in the accumulator tube until it rests square on the tube.5K 3K.000 4.000 6.312 2.131 .560 4.750 3.030 .032 1.025 3. Use hammer and a brass rod to tap piston into place until all of piston is 2 inches below beginning of honed bore.375 4.634 J 7 7 7 7 7 7 7 7 SERVICE 3K.750 2.001 11.110 5.0 Install gas valve after replacing the o-ring.250 3.0 390+ 25.782 7.104 . Remount accumulator and connect to hydraulic system.375 B 2.250 2.000 5.110 3.173 .000 4. Cap should be above the end of accumulator body within 1/32" to 3/32". Precharge accumulator to desired precharge pressure (where space is a problem it may be necessary to pre-charge accumulator before connecting it to the hydraulic system).110 4.620 1.562 3.030 .875 8. Illinois USA Maint.* RK0900Q000 12" RK1200K000 RK1200E000 C.S. = Consult Factory 2" RK0200K000 RK0200E000 RK0200D000 RK0200H000 RK0200Q000 3" RK0300K000 RK0300E000 RK0300D000 RK0300H000 RK0300Q000 4" RK0400K000 RK0400E000 RK0400D000 RK0400H000 RK0400Q000 Bore Size 6" RK0600K000 RK0600E000 RK0600D000 RK0600H000 RK0600Q000 7" RK0700K000 RK0700E000 RK0700D000 RK0700H000 RK0700Q000 9" RK0900K000 RK0900E000 RK0900D000 C.* 145 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.* C. 5824410000) to remove and replace new core.Catalog HY10-1630/US Piston Accumulators Parts List — Hydraulic Accumulators Hydraulic Accumulators Maintenance Instructions Item 1* 2* 3 4 5 5A 6 7 7A 8 8A 9 9A Part Description Body Hydraulic Cap Gas Cap Piston V-O-Ring V-O-Ring Back-Up Washers PTFE Ring (Piston) O-Ring O-Ring Back-Up Washer Gas Valve Gas Valve O-Ring Gas Valve Guard Screw * Some units may have these two components welded together.F. 7. L07471000*) which will contain gas valve core Part No. and some units rated above 3000 PSI will have valve per Figure 6 (Part No.F. Units. 8A) Material Buna-N (Std. 7". L07689000*).E. Use tool (Part No. 5822220000.F.F. A. Seal Kit Numbers (Includes items 5.* C. 7A. 9" and 12" bore sizes.F.) Fluorocarbon EPR Hydrogenated Nitrile Low Temp Nitrile *C.M. 6. 5A. . Other units will have gas valve per Figure 5 (Part No. Illinois USA .Catalog HY10-1630/US Piston Accumulators Hydraulic Accumulators Maintenance Instructions 146 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. when properly installed and maintained and used for their intended purpose. The program aims to ensure the free placing on the market and putting into service of relevant equipment within the European Union and the European Economic Area. Safe pressure equipment and assemblies are defined as those which. . which were identified by the European Community's program for the elimination of technical barriers to trade.) in order to ensure safe use. 147 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. manufacture. testing and conformity assessment of pressure equipment and assemblies of pressure equipement. will not endanger the health and safety of persons and. The purpose of the PED is to harmonise national laws of member states regarding the design. The Pressure Equipment Directive provides for a flexible regulatory environment which does not impose any technical solution.Catalog HY10-1630/US Piston Accumulators – CE Marking Hydraulic Accumulators Maintenance Instructions Hydraulic Piston Accumulators CE Marking What is the Pressure Equipment Directive? The Pressure Equipment Directive (PED) is one of the series of technical harmonisation directives covering subjects such as machinery. simple pressure vessels.. gas applicances etc.E. where appropriate. Units under 1 liter in gas capacity are designed and manufactured in accordance with Sound Engineering Practice (S. domestic animals and property. The Directive requires that all pressure equipment and assemblies within its scope must be safe when placed on the market and put into service. Such units do not bear the CE Marking.P. Units 1 liter and greater in gas capacity can be identified by a CE Marking place on the product label attached to the accumulator. Illinois USA Maint. 148 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. the value of which will be stamped on the nameplate. The accumulator can be mounted in any orientation. If a check valve prevents flow back to the pressure source (pump). However. manually operated shut-off device.Catalog HY10-1630/US Piston Accumulators – CE Marking Installation Hydraulic Accumulators Maintenance Instructions Most accumulators shipped from the factory will not be pre-charged. Illinois USA . which contains a connection to the accumulator should be designed so that it automatically discharges all hydraulic fluid from the accumulator when the equipment is turned off. a shut-off device is not required for safety reasons but may be appropriate for service and maintenance. vertically mounted with hydraulic port down is perferred. However. it should be rigidly mounted using any combination of the mounting holes provided at the hydraulic cap or proper clamps. Safety components may be connected by lines and/or installed in a safety block. Keep the hydraulic port covered to keep out foreign material until ready to make the hydraulic connections. in some cases they will be shipped with some amount of nitrogen charge. The accumulator must always be protected with sufficient discharge capacity. Example 1 Basic safety equipment for a single accumulator with permanently connected safety valve and gauge. gauge control port. pressure release device and return line to the reservoir. Example 2 Configuration with additional pressure release device which opens automatically in the case of circuit break down. The hydraulic circuit. . The safety valve is permanently communicating with the pressure line. 149 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.Catalog HY10-1630/US Piston Accumulators – CE Marking Example 3 Hydraulic Accumulators Maintenance Instructions Configuration with a 3/2-way-directional-control which simultaneously serves to isolate the accumulator from the presure line and release pressure to the return line. therefore also protecting the circuit. The accumulator is either protected by the safety valve or connected to the return line. Each individual accumulator may be isolated from the pressure line by a shut-off device and relased by a pressure device to a return line for maintenance purposes. Example 4 The above configuration shows a group of several accumulators connected with a single pressure line which is permanently connected with a gauge and a safety valve. An external control gauge connected to a quick coupling allows observation of the pressure at the fluid port of each individual accumulator. Illinois USA Maint. Catalog HY10-1630/US Piston Accumulators – CE Marking Example 5 Hydraulic Accumulators Maintenance Instructions Configuration similar to example 1 but with serveral accumulators each equipped with a safety block. Each safety block includes a safety valve, shut-off device, pressure release device and ports for the pressure line, the return line, gauge, control gauge and the accumulator itself. This configuration meets all safety requirements even for several pressure sources. Example 6 Configuration for a transfer type accumulator with additional gas bottles. Safety equipment for filling procedures is not shown. 150 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Piston Accumulators – CE Marking “U” Bolts for Piston-Type Accumulators Bore 3,000 PSI A2 A3 A4 A6 A7 A9 A12 "U" Bolt Part Number 0854370000 0862090000 0864960000 0864970000 0854400000 0854410000 0854420000 A 1/4 1/2 1/2 5/8 5/8 3/4 7/8 B 2-7/16 3-11/16 5 7-1/8 8-1/4 11-1/4 14-1/8 Hydraulic Accumulators Maintenance Instructions C 2-11/16 4-1/16 5-1/2 7-3/4 8-7/8 12 15 D 2-11/16 3-5/8 4-1/2 6-1/8 7 9-1/2 10-1/4 E 1-3/4 2 3 3-3/4 3-3/4 4-1/2 4-1/4 Thrd. 1/4-20 3/8-16 1/2-13 5/8-11 5/8-11 3/4-10 7/8-9 Wt. (lbs.) 0.2 0.9 1.3 2.5 3.0 6.0 8.2 Notes: 1) Accumulators should be mounted within 20° from vertical for optimal performance. 2) "U" Bolts should never be mounted more than 1 inch from end of accumulator. Piston Accumulator or Gas Bottle C B D E A Welded Lug (2 places) 1 inch max. 1 inch max. "U" Bolt (2 places) "U" Bolt Nuts included on all "U" Bolts. Mounting Holes (2 places) Mounting Plate 151 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Maint. Catalog HY10-1630/US Piston Accumulators – CE Marking Accumulator Sizing and Selection Software Hydraulic Accumulators Maintenance Instructions Parker offers leading edge application assistance, in the form of the InPHorm Accumulator Sizing and Selection Software or visit www.parker.com/accumulator for more information. For further engineering assistance, contact Parker's Accumulator Technical Support Group at (815) 636-4100. Accumulator Seals Piston accumulators are available for use with many operating medias. Fluid should be a non-dangerous liquid as well as precharged with an inert gas such as nitrogen. Available seal compounds are shown in the table below: Seal Code K E D H Q Operating Temperature Range -20°F to 165°F -29°C to 74°C -10°F to 250°F -23°C to 121°C -40°F to 250°F -40°C to 121°C -25°F to 320°F -32°C to 160°C -45°F to 185°F -43°C to 85°C **Recommended Polymer Buna Nitrile Fluorocarbon Elastomer Ethylene Propylene Hydrogenated Nitrile Low Temp. Nitrile Maximum Temperature with Reduced Life 200°F 93°C 400°F 204°C 300°F 149°C 350°F 177°C 200°F 93°C General Application and Compatibility* Parker's Standard Compound – Compatible with most mineral oil-based fluids Compatible with most mineral oil-based fluids at higher temperatures and some exotic fluids Compatible with most phosphate ester fluids and some synthetic fluids Compatible with most oil-based and biodegradable fluids, maintains sealing effectiveness at a wide range of temperatures Compatible with most mineral oil-based fluids and maintains sealing effectiveness at low temperatures *Note: Consult local distributor or factory for fluid compatibility information. Temperature ranges may vary depending upon fluid used in hydraulic system. ** The temperature listed indicates the operating temperature range of the seals, not the accumulator. Water Service Option (W) Piston accumulators are available for use with water as the fluid media. Modifications include electroless nickel plating all surfaces and metal parts. Consult factory for details. Corrosive Fluids and Enviromentments Standard piston accumulators are not designed for corrosive fluids and enviroments. Consult factory for special options for these types of fluids and enviromentments. Accumulator Storage In order to prepare a piston accumulator for proper storage for future use, the piston must be moved off the hydraulic cap by as much as 2 inches. Proceed by pouring 10 to 150 cubic inches (depending on the size of accumulator) of the system fluid through the hydraulic port in the accumulator end and plug the port using a stainless steel fitting, then pre-charge the unit with nitrogen to 100±10 psig to allow equal pressure on both sides of the seal. The pre-charge should be bled off and the system fluid in the accumulator must be drained prior to installation of the piston accumulator on the system . It is also recommended that the units be stored in a vertical position to prevent the seals from developing a set (flat spot) on the side that the piston weight is exerted. The piston accumulator should be stored in a cool, dry place away from sun, ultraviolet and fluorescent lights as well as electrical equipment. Direct sunlight or fluorescent light can cause the seals to weather check and dry rot, which appear on the seal and o-ring surface as cracks. The ideal temperature for storage is 70°F. 152 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Catalog HY10-1630/US Piston Accumulators – CE Marking Pre-Charging Use an inert gas such as nitrogen for pre-charging piston accumulators. Do not use oxygen or shop air. If water pumped nitrogen is not available, oil-pumped nitrogen may be used. (C.G.A. standards: Nitrogen gas bottles for water pumped nitrogen has a right-hand valve thread which requires charging and gauging assembly †144595XX00 for units up to 3000 psi. Oil-pumped nitrogen requires a left-handed valve thread (use †144596XX00). For all 3000 psi rated accumulators, use assembly †144595XX00 (Figure 1). For accumulators rated over 3000 psi and the precharge requirement is above 2300 psi, use †870816XX00 (See Figure 3). If equipment other than the above listed is used, make sure it is compatible with the gas valve assembly. Nitrogen source and all components must be rated for a pressure at least as high as the nitrogen source. It is strongly recommended that the nitrogen bottle used have the appropriate pressure high pressure regulator (not included). Make sure nitrogen supply is shut off. Attach hose to nitrogen bottle. If accumulator has a gas valve as shown in Figure 5 follow steps A through L and skip steps F and J. If accumulator has a gas valve as shown in Figure 6, follow steps A through L and skip steps E and I. Accumulator having gas valve as per Figure 5. (A) Remove gas valve guard and gas valve cap. (B) Back gas chuck “T” handle all the way out (counter clockwise) before attaching charging assembly to accumulator gas valve. (C) Close bleed valve. (D) Making sure not to loop or twist the hose, attach swivel nut to gas valve and tighten (10-15 in. lb.) (11.5-17 cm kg). (E) Turn gas chuck “T” handle until the gauge starts showing the pressure in the accumulator. Do not turn the "T" handle all the way down, as it will damage the valve core. (F) For gas valves as shown in Figure 6, hold gas valve at point “C” with one (1) wrench while un screwing hex nut at point “D” with a second wrench. This will open the poppet inside the gas valve. Note: Three (3) turns will fully open the valve. (G) Crack open nitrogen bottle valve and slowly fill accumulator. Shut off when gauge indicates desired pre-charge. (H) Let the pre-charge set for 10 to 15 minutes. This will allow the gas temperature to stabilize. If the desired pre-charge is exceeded, close nitrogen bottle valve, then slowly open bleed valve (Figure 1). Do not reduce pre-charge by depressing valve core with a foreign object. High pressure may rupture rubber valve seat. (I) When finished pre-charging accumulator, turn “T” handle all the way out on gas chuck (Figure 1), then open bleed valve. (J) For gas valves as shown in Figure 6, with a wrench, tighten hex nut at point “D” to close internal poppet (5-8 ft. lbs.) (5.7-9.2 cm kg). (K) Hold gas valve to keep from turning, loosen swivel nut, remove assembly. Check for precharge leak using a common leak reactant. (L) Replace gas valve cap (10-15 in. lbs.) (11.5-17 cm kg) and valve guard. (Gas valve cap serves as a secondary seal.) † "XX" Denotes to gauge pressure. Hydraulic Accumulators Maintenance Instructions FIGURE 1 PART #144595XX00 FIGURE 2 PART #085122XX00 3000 PSI UNITS Part Number 144595XX00 (Std) (Right-Hand) Charging and Gauging Assembly for Cored Accumulators Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings adapter incorporating gas valve, bleeder valve and gas chuck (less gauge). For left-hand thread nitrogen bottle fitting, specify part number144596XX00. Part Number Gauging Assembly for Cored Accumulators 085122XX00 Gauging device consisting of adapter incorporating gas valve, bleeder valve and gas chuck (less gauge). FIGURE 3 PART #870816XX00 FIGURE 4 PART #871372XX00 5000 PSI UNITS Part Number 870816XX00 Charging and Gauging Assembly for 5000 PSI Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings (1.035-14 NGO female)adapter incorporating gas valve, bleeder valve and gas chuck (less gauge). Gauging Assembly for 5000 PSI Gauging device consisting of adapter incorporating gas valve, bleeder valve and gas chuck (less gauge). Part Number 871372XX00 POINT “D” VALVE CORE POINT “C” ACCUMULATOR FIGURE 5 FIGURE 6 Part #L07471000* Gas Valve with medium pressure core for 3000 psi service, and Part #L07688000* Gas Valve with high pressure core for 5000 psi service. Part #L07689000* Gas Valve with poppet for ASME units 7, 9, 12 bore and some 5000 psi units 153 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford, Illinois USA Maint. (15) Replace gas cap and tighten (10-15 in.5-17 cm kg). and thereafter once a month. or damage. using a long bar working against the pins. Remove piston by pushing from hydraulic end with a bar. remove assembly.) (5. Turn 2-3 times and read pre-charge. Replacement of other seals on end caps and gas valve is recommended (see Kit Numbers). (6) To remove gauging assembly turn “T” handle all the way out on gas chuck (Figure 1).) (11. Threaded holes in hydraulic cap may be used as a means of attachment for lifting. Periodic checking of pre-charge pressure will detect whether Vo-ring wear is sufficient to begin reducing sealing performance. from time of its pressure checking. Then remove gauging assembly and gas valve. lint-free cloth soaked in clean solvent. (4) Attach swivel nut to gas valve and tighten (10-15 in. If pre-charge is low. It is suggested that a check be made a week after installation. Inspect end caps for damaged threads or burrs on oring grooves. burrs around o-ring grooves. then open bleed valve. (2) Back gas chuck “T” handle all the way out (counter clockwise) before attaching charging assembly to accumulator gas valve. pre-charge pressure will rise if oil gathers in the gas side and will fall if gas leaks into the oil side or out past gas end seals. lift seal with small smooth screw driver or similar tool. and install gas valve guard. use assembly as shown in Figure 4 (Part #87127XX00). IN BOTH CASES ALWAYS REMOVE THE GAS CAP FIRST (end cap which contained gas valve). lb. lbs. Examine body bore. Then hold valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench. (8) Replace gas valve cap (10-15 in. Wait until all gas pre-charge is relieved from the accumulator and then remove gas valve. remove gas valve guard and gas valve cap.7-9. Remove accumulator from hydraulic system. For accumulators rated for 3000 psi or less. attach gauging assembly as shown in Figure 2 following Steps 1 through 5. Accumulators having gas valve as per Figure 6. moving the tool around the piston several times while using the other hand to work ring off the piston. At this point the piston will be bottomed at the hydraulic end. unthread the cap from the body. Replace PTFE wear rings. then. For accumulators having gas valve as shown in Figure 6. NEVER TRY TO REMOVE PISTON BY APPLYING COMPRESSED AIR AT OPPOSITE END. (11) Attach swivel nut to gas valve and tighten (10-15 in. Inspection Inspect piston for cracks. (9) Remove gas valve guard and gas valve cap. This will depress core in gas valve and check pressure. For accumulators having gas valve as shown in Figure 5.Catalog HY10-1630/US Piston Accumulators – CE Marking Maintenance Repair Kits (see Parts List) are available for all accumulator models. Accumulators having gas valve as per Figure 5. For accumulators rated over 3000 psi up to 5000 psi. also check for gas valve and/or end seal leakage. Repair and Replacement Minor nicks. using a light. lb. To remove V-o-ring from piston. (12) Hold gas valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench. open bleed valve until all gas pre-charge is relieved from accumulator. To remove cap or caps. (5) Turn gas chuck “T” handle all the way down. Cleaning Thoroughly clean metal parts in solvent and dry with compressed air. Also specify fluid and temperature at which used.5-17 cm kg). (3) Close bleed valve. loosen swivel nut.5-17 cm kg) and valve guard. lay the accumulator horizontally and hold down with a strap wrench or in a vise. Allowing for temperature difference. Vo-rings.) (11.2 cm kg) then open bleed valve to relieve residual gas charge in the gauging assembly. Occasional replacement of V-o-ring seal on the piston is generally the only maintenance required. (1) Remove gas valve guard and gas valve cap. Illinois USA . if any. lb. (7) Hold gas valve from turning.) (11. Disassembly of Accumulator Once the gas valve is removed. This will open the poppet inside the gas valve. discharge all oil from accumulator and allow piston to bottom against hydraulic end cap. Dress bore until all apparent imperfections have been removed. When ordering repair kits. tighten hex nut at point “D” to close internal poppet (5-8 ft. install three (3) pins into the holes in the cap. o-rings and their respective back up washers if the 154 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. (10) Close bleed valve. Hydraulic Accumulators Maintenance Instructions (14) Hold gas valve at point “C” with wrench and remove swivel nut assembly. for scratches or scoring. (13) With a wrench. or use a sling around the body. Remove from Hydraulic System Shut equipment down and make certain that hydraulic pressure at the accumulator is at zero. Pre-charge Checking Procedure Using appropriate valve in the hydraulic system.) (11. Then.5-17 cm kg). Some accumulators may have both end caps threaded into the body and some units may only have the gas cap threaded into the body. use gauging assembly as shown in Figure 2 (Part #085122XX00). Remove o-rings and back-up rings from end cap. state complete model number from nameplate. lbs. scratches or light scoring of the body bore can be removed by using crocus cloth. Clean bore of body with a clean. Bore must be clean of any visible particles or particles detectable to touch. 560 4.030 G 1.312 1.0 390 + 25. Remount accumulator and connect to hydraulic system.562 3.112 5.173 .001 9.110 4.150 12.750 2.000 14. Insert the piston in the starting sleeve with the dished side of the piston toward the gas end.782 7. End cap will stop against chamfer leading into honed bore (all caps must be tightened to proper torque as per following chart).030 .750 6.375 4. Starting sleeve dimensions are shown below.002 5. It is highly recommended to use a piston starting sleeve for reassembly of piston accumulators. .000 4.000 4.0 160 + 10. then a new o-ring on threaded end cap or caps and install into body bore.110 5.150 9.500 6.4K.0 390 + 25.104 .375 B 2. Cap should be above the end of accumulator body within 1/32" to 3/32".0 220 + 15. Use hammer and a brass rod to tap piston into place until all of piston is 2 inches below beginning of honed bore. Install new back-up ring first.030 .000 6. Precharge accumulator to desired precharge pressure (where space is a problem it may be necessary to pre-charge accumulator before connecting it to the hydraulic system).375 5.634 J 7 7 7 7 7 7 7 7 SERVICE 3K.562 2.312 2.875 H 1.5K 3K.000 4.124 . Call the factory for price and delivery.250 11.110 3.030 .131 .620 1.375 C 2.0 390 + 25.0 Install gas valve after replacing the o-ring.375 3.864 7.268 F .032 1. Insert the starting sleeve in the accumulator tube until it rests square on the tube.375 2.105 D 2.001 11.4K.876 E . PARTS LIST PART NUMBER PSD0000002 PSD0000003 PSD0000004 PSD0000005 PSD0000006 PSD0000007 PSD0000009 PSD0000012 A 2.000 5.030 5. Illinois USA Maint.030 .250 2.030 .030 .030 .089 .500 4.375 1.025 3. Hydraulic Accumulators Maintenance Instructions BORE SIZE 2 3 4 6 7 8 9 12 ASSEMBLY TORQUE Ft-Lb 50 + 5.100 .5K 3K 3K 3K 3K 3K 3K BORE SIZE 2 3 4 5 6 7 9 12 155 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.0 90 + 7.250 3.875 8.174 .0 390 + 25. Care should be exercised not to drag o-ring over threads.500 3.750 3.375 1.Catalog HY10-1630/US Piston Accumulators – CE Marking Reassembly Coat all internal parts with clean hydraulic fluid before reassembly. 7".Catalog HY10-1630/US Piston Accumulators – CE Marking Parts List — Hydraulic Accumulators Hydraulic Accumulators Maintenance Instructions Item 1* 2* 3 4 5 5A 6 7 7A 8 8A 9 9A Part Description Body Hydraulic Cap Gas Cap Piston V-O-Ring V-O-Ring Back-Up Washers PTFE Ring (Piston) O-Ring O-Ring Back-Up Washer Gas Valve Gas Valve O-Ring Gas Valve Guard Screw * Some units may have these two components welded together. Seal Kit Numbers (Includes items 5. 5824410000) to remove and replace new core. Other units will have gas valve per Figure 5 (Part No. L07689000*).) Fluorocarbon EPR Hydrogenated Nitrile Low Temp Nitrile *C.F. A.E.M. 7A.* C.* C. 9" and 12" bore sizes. 6. and some units rated above 3000 PSI will have valve per Figure 6 (Part No. Illinois USA . Use tool (Part No.F.F. 5822220000.F. = Consult Factory 2" RK0200K000 RK0200E000 RK0200D000 RK0200H000 RK0200Q000 3" RK0300K000 RK0300E000 RK0300D000 RK0300H000 RK0300Q000 4" RK0400K000 RK0400E000 RK0400D000 RK0400H000 RK0400Q000 Bore Size 6" RK0600K000 RK0600E000 RK0600D000 RK0600H000 RK0600Q000 7" RK0700K000 RK0700E000 RK0700D000 RK0700H000 RK0700Q000 9" RK0900K000 RK0900E000 RK0900D000 C. 5A.F.S.* RK0900Q000 12" RK1200K000 RK1200E000 C. L07471000*) which will contain gas valve core Part No. Units.* 156 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 8A) Material Buna-N (Std. 7. the value of which will be marked on the label/ nameplate. which is shown in the Accumulator Accessories section of this catalog. However. In. in some cases they will be shipped with a nitrogen charge. should be designed so that it automatically discharges all hydraulic fluid from the accumulator when the equipment is turned off. In this case the precharge will not be listed on the label. It should also be rigidly mounted using appropriate mounting hardware. The hydraulic circuit. Keep the hydraulic port covered to keep out foreign material until ready to make the hydraulic connections. through 40 Gallons 3.000 psi Standard Bottom and Conventional Top Repairable Installation All accumulators shipped from the factory will be precharged to a nominal pressure in order to seat the poppet valve on the hydraulic port. The accumulator should be mounted within 25° of vertical with the hydraulic port on the bottom.Catalog HY10-1630/US Bladder Accumulators Hydraulic Accumulators Maintenance Instructions BLADDER PRODUCTS Series “BA” Bladder Accumulators ■ ■ ■ 10 Cu. Illinois USA Maint. . 157 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. which contains a connection to the accumulator.000 and 5. auxiliary power supply or leakage compensation. When the accumulator is used to supplement pump flow. the bladder may suffer permanent damage. Part †144596XX00. Oil-pumped nitrogen requires a left-handed valve thread (use †144596XX00). Attach hose to nitrogen bottle. a valve extension as shown in Figure 3 must be attached to the gas valve after removing valve cap.) Damage to bladder may occur if this ratio is not maintained or exceeded.) FIGURE 5 PART #087101XX00 (1-15 GAL. Check for precharge leak using a common leak reactant. Do not use oxygen or shop air. as well as the 25-40 gallon. precharge is usually set at approximately 90% of minimum system pressure. It is strongly recommended that the nitrogen bottle used have the appropriate pressure high pressure regulator (not included).5-17 cm kg). and in Figure 4 Part †087100XX00 for 1-15 gallon & Part †087102XX00 for 10-150 cu. This will open the poppet inside the gas valve. Standards: Nitrogen gas bottles for water pumped nitrogen has a right-hand valve thread which requires charging and gauging assembly †144595XX00 for units up to 3000 psi.A.79. right-hand thread.) FIGURE 1 PART #144595XX00 FIGURE 2 PART #085122XX00 CAN BE USED ON 3. then open bleed valve. For accumulators rated for 5. IN. Make sure nitrogen supply is shut off. precharge is usually set at about 65% of system pressure. as it will damage the valve core.G. follow steps A through L and skip steps E and I. with a wrench. Do not reduce precharge by depressing valve core with a foreign object.000 psi. 085434 0000 FOR USE ON CONVENTIONAL TOP REPAIRABLE UNITS IN CONJUNCTION WITH FIGURES 1 OR 2 NOTE: For top repairable units having valves as shown in Figure 8B. Do not turn the “T” handle all the way down.) (11. (H) Let the precharge set for 10 to 15 minutes. If accumulator has a gas valve as shown in Figure 9. Hydraulic Accumulators Maintenance Instructions (I) When finished precharging accumulator.) CAN BE USED ON BOTTOM AND TOP REPAIRABLE 3. accumulator rated for 3. Note: Three (3) turns will fully open the valve. If accumulator has a gas valve as shown in Figure 8A or 8B. (B) Back gas chuck “T” handle all the way out (counterclockwise) before attaching charging assembly to accumulator gas valve. All components must be rated for a pressure at least as high as the nitrogen source. 3. lb. hold gas valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench. (L) Replace gas valve cap (10-15 in. Illinois USA . It is recommended to use charging and gauging assembly as shown in Figure 1 (Part †144595XX00.) (11. (J) For gas valves as shown in Figure 9. This will allow the gas temperature to stabilize.000 PSI BOTTOM REPAIRABLE BLADDER ACCUMULATORS FIGURE 3 VALVE EXTENSION P.) PART #087103XX00 (10-150 CU. (C) Close bleed valve. (E) Turn gas chuck “T” handle until the gauge starts showing the pressure in the accumulator. tighten not hex nut at point “D” to close internal poppet (5-8 ft. in. use assembly shown in Figure 6 (Part †870816XX00).N. follow steps A through L and skip steps F and J. make sure it is compatible with the gas valve assembly and nitrogen source. If other equipment is used. (C. left-hand thread).Catalog HY10-1630/US Bladder Accumulators Pre-Charging Use only an inert gas such as nitrogen for precharging piston accumulators.) (5. If the desired precharge is exceeded.) PART #087102XX00 (10-150 CU. (G) Crack open nitrogen bottle or regulator valve and slowly fill accumulator. loosen swivel nut. For shock suppression applications. Shut off when gauge indicates 100 psi above desired precharge. lbs. then slowly open bleed valve. Accumulators having gas valve per Figure 8A or 8B (A) Remove gas valve guard and gas valve cap. IN.5-17 cm kg) and valve guard.000 psi or less. FIGURE 4 PART #087100XX00 (1-15 GAL. (F) For gas valves as shown in Figure 9. Caution: If the precharge is not done slowly. turn “T” handle all the way out on gas chuck. oil-pumped nitrogen may be used.000 psi accumulators. (D) Making sure not to loop or twist the hose. lbs. close nitrogen bottle valve. (Gas valve cap serves as a secondary seal. remove assembly. High pressure may rupture rubber valve seat. (Note: It is recommended that precharge pressure be at least 25% of maximum system pressure.000 PSI ACCUMULATORS † “XX” Denotes to gauge pressure 158 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. attach swivel nut to gas valve and tighten (10-15 in.2 cm kg). included. If water pumped nitrogen is not available. (K) Hold gas valve to keep from turning. Illinois USA FIGURE 8A FIGURE 8B 3000 PSI VALVES FIGURE 9 5000 PSI VALVES Maintenance Little maintenance is required for a bladder accumulator. check gas valve for leakage and recharge. hold valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench until gas begins to escape through the top of the valve. Hold gas valve from turning.) (11. tighten hex nut at point “D” to close internal poppet (10-15 in. remove accumulator from system and replace faulty components.) (29-35 cm kg) when using gauging assembly in Figure 4. Open bleed valve and release all the gas pressure. Tighten assembly (25-30 in.) (11. (9) Close bleed valve. when using gauging assembly in Figure 1. Remove gas valve guard and gas valve cap. To remove gauging assembly. . 25-40 GALLON 3000 PSI AND 5000 PSI RATED UNITS EQUIPPED WITH MS GAS VALVE AS SHOWN IN FIGURE 9.15 gallon. four (4) turns will fully open poppet. If necessary. lb. tighten all connections.40 GALLON 3000 PSI AND ALL 5000 PSI UNITS Part Number 870810 XX00 Charging and Gauging Assembly for 25-40 Gal. remove valve core. If there is external leakage.5-17 cm kg) and valve guard. Note. Part Number 871372 XX00 Removal of Accumulator From Hydraulic System Shut equipment down and make certain that hydraulic pressure at the accumulator is at zero. Remove accumulator from hydraulic system.5-17 cm kg) and install gas valve guard. (14) Replace cap on gas valve (10-15 in. If there is no gas in bladder and fluid appears at gas valve. in. For accumulators rated for 3000 psi.) Part Number 085434 XX00 (2) (3a) Attach gauging assembly to gas valve or to gas valve extension and tighten swivel nut (10-15 in. using valve core removing tool (Part #582441XX00).) 087100 XX00 (1-15 gal. (6) (7) FIGURE 6 PART #870816 XX00 FIGURE 7 PART #871372 XX00 25-40 GALLON 3000 PSI AND 5000 PSI RATED UNITS EQUIPPED WITH MS GAS VALVE AS SHOWN IN FIGURE 9. 3000 & 5000 PSI Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings (1. SAE #6 Wait until all the gas pressure has been released. check pre-charge monthly. Close bleed valve and turn “T” handle all the way out. 159 Maint. and (Part #087101XX00) for 1 . Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. (3b) Install gas valve o-ring on the gas valve. If leakage continues. Gauging Assembly for 3000 PSI Bottom Repairable Gauging device consisting of adapter incorporating gas valve bleeder valve and gas chuck including gauge. hold gas valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench. (For top repairable unit connect valve extension Part #085434XX00) as shown in Figure 3 and tighten with wrench. which will depress core in gas valve and check pressure. turn “T” handle all the way out and then open bleeder valve. loosen swivel nut and remove assembly. For these units. This will open the poppet inside the gas valve. lb.) (11.) Remove accumulator from hydraulic system. Thereafter. Check pre-charge if the system is acting sluggish. For left-hand thread nitrogen bottle fitting specify part number 144596 XX00. 3000 PSI RATED UNITS (1) Remove gas valve guard and gas valve cap. then install cap on gas valve (10-15 in.5-17 cm kg). Check pre-charge pressure.035-14 NGO female) adapter incorporating gas valve bleeder valve and gas chuck (less gauge). lb.15 gal.) Part Number 085122 XX00 Part Number 087103 XX00 (10-150 cu. Detach gauging assembly and. (Caution: Keep face away from gas valve as the high pressure nitrogen is discharging.) 087101 XX00 (1 . use gaging assembly in Figure 7 (Part #871372XX00) and follow steps 8 through 14. Valve Extension for 3000 PSI Contains extension and valve core. Gauging Assembly for 5000 PSI Gauging device consisting of adapter incorporating gas valve bleeder valve and gas chuck (less gauge).Catalog HY10-1630/US Bladder Accumulators Part Number 144595 XX00 (Std) (Right Hand) Charging and Gauging Assembly for 3000 PSI Bottom Repairable Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings adapter incorporating gas valve bleeder valve and gas chuck (less gauge). Part Number 087102 XX00 (10-150 cu. (12) With wrench. (4) (5) Turn “T” handle all the way down. and attach gauging assembly to valve stem. attach gaging assembly (Part #085122XX00) or (Part #087103XX00)for 10 . either use gaging assembly in Figure 2 (Part #085122XX00) or gaging assembly in Figure 5 (Part #087101XX00) and follow Steps 1 through 7.) (11. (8) Remove gas valve guard and gas valve cap. after removing valve cap. Gauging Assembly for 3000 PSI Top Repairable Gauging device consisting of adapter incorporating gas valve bleeder valve and gas chuck (less gauge). in. If pre-charge is low. 25 . After original installation. For these units. POINT “D” VALVE CORE POINT “C” VALVE CORE ACCUMULATOR (11) Referring to Figure 9. Hydraulic Accumulators Maintenance Instructions For accumulators rated for 5000 psi. discharge all oil from accumulator. Charging and Gauging Assembly for 3000 PSI Bottom & Top Repairable Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings adapter incorporating gas valve bleeder valve and gas chuck (less gauge). lb. Pre-charge Checking Procedure Using appropriate valve in the hydraulic system. check pre-charge once during first week to see that no leak has developed.) (11. (10) Attach gauging assembly to gas valve and tighten swivel nut (10-15 in. Accumulators rated for 5000 psi will have a gas valve as shown in Figure 9. lb. (13) Hold gas valve at point “C” with a wrench and remove swivel nut assembly.150 cubic inch. lb. remove valve extension. 3000 PSI RATED UNITS Accumulators rated for 3000 psi will have a gas valve as shown in Figure 8A or 8B.5-17 cm kg). unit must be removed and bladder replaced.5-17 cm kg). the accumulator body should be secured in a vise. attach the bladder pull rod to the bladder valve stem. If bladder is slippery. Seperate the antiextrusion ring from the hydraulic port. FIGURE 5 FIGURE 9 6. brass inserts should be used to protect the accumulator hydraulic port assembly from damage. Remove spacer. Insert the bladder pull rod through the valve stem opening and through FIGURE 8 FIGURE 3 FIGURE 4 the shell fluid port. Fold bladder and pull out of accumulator shell. Secure valve stem from twisting with an appropriate wrench applied to the valve stem flats. 160 . After shell has been cleaned and inspected. If rust is detected. discard bladder. After testing. If soap solution bubbles. Insert hand into the accumulator shell and remove the o-ring backup. remove lock nut from the hydraulic port assembly. With one hand. 4. 2. 2. Remove jam nut from bladder valve stem. Special attention should be given to the area where the gas valve and hydraulic assembly pass through the shell. Once the bladder valve stem has been pulled through the valve stem opening in the shell. If protective plating is damaged. Figure 5. If a standard jaw vise is used. Once the accumulator has been removed from the equipment. With all gas completely exhausted from bladder. Figure 6. Disassembly of Conventional Top-Repairable Accumulators The conventional topGAS END PROTECTIVE repairable accumulator ADAPTER CAP 1-5/16" HEX NUT uses a gas-end adapter OUTER which is retained in the LOCKNUT shell with an anti-extrusion ANTIring exactly like those EXTRUSION RING used in port assemblies (see Figure 10). deflate bladder immediately. install the valve stem nut by hand. replace all worn or damaged seals with original equipment seals from the Hydraulic Accumulator Division. 3. Clamp on wrench flats only when using a jaw vise to prevent accumulator from turning. Figure 7. Figure 8. then push the hydraulic port assembly into the shell prior to Step 4. Figure 4. FIGURE 2 Bladder Assembly in Bottom Repairable Accumulators 1. FIGURE 6 Hydraulic Accumulators Maintenance Instructions Hydraulic Port: Inspect assembly for damage. Fold antiextrusion ring to enable removal of anti-extrusion ring from shell. Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. FIGURE 10 (See Removal of Accumulator from System). In cases where the accumulator is used with water. 1. Using a spanner wrench. Once the valve stem nut is in place. Any nicks or damages in this area could destroy the accumulator bladder or damge new seals. Make sure the entire internal of the shell is lubricated. replace accumulator shell in vise or on table. Make sure the gas is relieved from the accumulator. Shell: After shell has been cleaned with a cleansing agent. FIGURE 7 Bladder: Inflate bladder to normal size. replace with new components. remove the bladder pull rod. replace with new components. FIGURE 1 Seals: Check anti-extrusion ring and soft seals for damage and wear. 5. Figure 9. check assembly for rust and/or defective plating. If this area is pitted consult factory. preferably a chain vise. Figure 3. check the inside and outside of shell. Spray the inside of the accumulator shell with approximately 10% of the accumulator volume with clean system fluid to lubricate and cushion bladder. pull the bladder pull rod while feeding the bladder into the shell with the other hand. Remove bleeder plug (if the accumulator is equipped with one) on hydraulic port assembly. If parts are pitted. metal backup. clean with commercial rust remover.Catalog HY10-1630/US Bladder Accumulators Disassembly of Bottom Repairable Accumulators Figure 1. Slight twisting of bladder will assist in this insertion. hold with a cloth. use an adjustable wrench on the flats located on the port assembly to prevent port assembly from rotating. Seals and soft parts should be wiped clean. collapse bladder and fold longitudinally in a compact roll. A slight twisting motion while pulling on the bladder reduces effort required to remove bladder from shell. o-ring. Illinois USA Clean & Inspect Cleaning:All metal parts should be cleaned with a cleaning agent. check the poppet plunger to see that it spins freely and functions properly. Wash bladder with a soap solution. Figure 2. Remove hydraulic port plug from accumulator shell. Remove jam nut from bladder gas valve stem using a 1-5/16" socket wrench. 3. Seals: Check anti-extrusion ring and soft seals for damage and wear. Remove gas end adapter from shell. insert the poppet end into the shell fluid port. This will squeeze the o-ring into position. 2. Bladder: Inflate bladder to normal size. Install the outer spacer. Install accumulator on machine. Make sure the entire internal surface of the shell is lubricated. 3. Install o-ring backup over hydraulic port assembly and FIGURE 14 push until it bottoms against o-ring (1-40 gallon sizes and 5K only). Holding the gas end adapter in place. If parts are pitted. Spray the inside of the accumulator shell with a liberal amount of clean system hydraulic fluid to lubricate and cushion the bladder. Bladder Assembly in Conventional Top-Repairable Accumulators 1. 4. replace all worn or damaged seals with original equipment seals from the Accumulator Division. collapse bladder and fold longitudinally in a compact roll. This will hold the gas end adapter in place. 12. Fold the anti-extrusion ring and remove from shell. After testing. Insert hand into accumulator. Position accumulator so that fluid (same fluid as used in the system) can be poured into the accumulator (add approximately 10% of the accumulator capacity). o-ring and metal back-up. 8. Push the gas end adapter complete with the bladder into the shell. Install the lock-nut on the hydraulic port assembly and tighten securely. fill accumulator with approximately 50 PSI nitrogen. Figure 13. Illinois USA Maint. replace with new components. 6. CAUTION: Do not twist oring. Wash bladder with a soap solution. Holding the hydraulic port assembly by the threaded end. 7. remove the o-ring back-up. 4. Reaching inside the accumulator. 11. 5. 8. Install the outer locknut. In cases where the accumulator is used with water. Hydraulic Accumulators Maintenance Instructions Hydraulic Port Assembly Installation 1. check the inside and outside of shell. If soap solution bubbles. 10. discard bladder. 8. Figure 12. 161 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. o-ring and o-ring backup. Separate the anti-extrusion ring from the gas end adapter. 11. Thread bleeder plug into the hydraulic port assembly. Using a spanner wrench. install valve core into the bladder stem. Pre-charge accumulator to desired pressure. Fold anti-extrusion ring and place inside accumulator. Seals and soft parts should be wiped clean. Use appropriate wrench on flats of port assembly to insure the unit does not turn. 6. clean with commercial rust remover. Slowly pressurize the bladder. 10. insert the gas end adapter through the anti-extrusion ring and pull into place. Figure 11. Clean & Inspect Cleaning: All metal parts should be cleaned with a cleaning agent. consult factory. place the anti-extrusion ring on the poppet assembly with the steel collar facing toward FIGURE 11 the shell fluid port. 6. NOTE: Conventional top repairable accumulators may be repaired by removing the bladder from either the hydraulic end or the gas end of the accumulator. . 9. Install the metal backup.Catalog HY10-1630/US Bladder Accumulators 3. With port assembly firmly in place. Once the anti-extrusion ring has cleared the fluid port opening. FIGURE 12 using dry nitrogen with sufficient pressure (approximately 40-50 psi) to hold poppet assembly in place so both hands are free to continue with assembly. Hydraulic Port: Inspect assembly for damage. Any nicks or damages in this area could destroy the accumulator bladder or damage new seals. Fold antiextrusion ring to enable insertion into the shell. Insert bladder into accumulator shell. If rust is detected. remove outer lock nut on the gas end adapter. Lay complete assembly inside shell. If these areas are pitted. 5. Special attention should be given to the area where the gas valve and hydraulic assembly pass through the shell. 5. Pull the threaded end of the port assembly through the shell fluid port until it seats solidly into position on the shell fluid port opening. deflate bladder immediately. 7. check assembly for rust and/or defective plating. Remove bladder from shell. Figure 14. Install o-ring over hydraulic port assembly and push it into the shell fluid port until it has bottomed out against washer. Shell: After shell has been cleaned with a cleansing agent. With all air completely exhausted from bladder. See Figure 4. Install the gas end adapter on the bladder and secure with jam nut. 4. See precharge instructions. check the poppet plunger to see that it spins freely and functions properly. The steel surface on anti-extrusion ring should face outward. 2. If protective plating is damaged. Insert gas end adapter. replace with new components. Install metal backup washer over hydraulic port assembly and push into the shell fluid port FIGURE 13 to bottom it out on antiextrusion ring. 9. 7. Insert spacer with the smaller diameter of the shoulder facing the accumulator shell. This fluid will act as a cushion when the accumulator is pre-charged with gas. 06 . lbs.▲ 1 . lbs.Ref. O-ring O-ring Back-up O-ring Back-up Metal Top Adapter Gas Valve O-ring (Gas Valve) Back-up Washer (Stem) O-ring (Stem) Bladder Assembly Part Numbers Seal Type Accumulator .19.7.19. Figure D and contains Items 2.150 C. 702970 702972 702973 702974 702976 5 Gal. 1 . lbs.08 .25 & 26* 10 Cu.) Lock Nut Outer (21/2-15 g.) Lock Nut Outer (1 gal. 702998 703000 703001 703002 703004 11 Gal. 706000 706002 706003 706004 706006 5 Gal. Figure E Contains Items 2.4.40 Gal. 0850695100 0856665100 0850705100 0851055100 0851045100 15 Gal. lbs.18. Figure F Contains Items 2.B & C.** 702928 702930 702931 702932 702934 150 Cu. 702914 702916 702917 702918 702920 1 Qt. lbs.28 Size Nitrile (NBR) Hydrin Butyl EPR Fluorocarbon 3000 PSI . 704060 704062 704063 704064 704066 1" ∅ Stem 2 1/2 Gal.7. 4. 73 ft.2" Valve Stem Ref. Gas Valve Assembly Part Numbers Size † Contains items 3.) Gas Valve Cap 14 ft. 200 ft. 56 ft.25 & 26 2 1/2 Gal.*** 702956 702958 702959 702960 702962 2 1/2 Gal.† 25 . 25 & 26. Figures A. Contains Items 2. 3-4 in. 702942 702944 702945 702946 702948 1 Gal. Suggested Approximate Torque Values Protective Cap Lock Nut (Jam) Valve Core Bleeder Plug Lock Nut Outer (1 qt.3. 0870445100 0870485100 0870455100 0870475100 0870465100 15 Gal.Standard . 703012 703014 703015 703016 703018 15 Gal.25 & 26 2 1/2 Gal. ***Contains items 2. 703340 704008 704009 703341 703342 40 Gal. & 4 as shown in Figure A.26.15 Gal. 707030 706032 706033 706034 706036 5000 PSI . 8706135010 8706175010 8706145010 8706145010 8706155010 7/8" ∅ Stem 1 Gal. 0870445050 0870485050 0870455050 0870475050 0870465050 10 Gal.20. lbs.Catalog HY10-1630/US Bladder Accumulators Accumulator Parts Description 6 5 Hydraulic Accumulators Maintenance Instructions 6 5 4 3 25 6 5 4 26 11 14 1 19 18 20 15 2 24 2 7 25 26 11 14 1 19 18 20 15 24 2 2 1 28 30 6 5 7 25 26 6 5 7 25 26 1 2 1 5 4 3 1 2 3 25 26 1 FIGURE A 3000 PSI 10 CI -150 CI Item No. 702900 702902 702903 702904 702906 1 Pt. 706020 706022 706023 706024 706026 15 Gal.I. lbs. 706010 706012 706013 706014 706016 10 Gal. 0850695025 0856665025 0850705025 0851055025 0851045025 5 Gal. ▲ Contains items 7. 702984 702986 702987 702988 702990 10 Gal. 703346 704014 704015 703347 703348 5000 PSI . 0850695150 0856665150 0850705150 0851055150 0851045150 *See page164 for items 18-20.18. 275 ft.04 .3. Illinois USA . lbs.25.3.25 & 26. 10-15 in.28 & 30 1 Gal. In.Ref. 1 2 3 4 5 6 7 11 14 15 18 19 20 24 25 26 28 30 FIGURE B 3000 PSI 1-15 GALLON FIGURE C 3000 PSI CONVENTIONAL TOP REPAIRABLE FIGURE D 5000 PSI CONVENTIONAL TOP REPAIRABLE FIGURE E 5000 PSI 2" VALVE STEM FIGURE F 5000 PSI Description Shell Bladder O-ring Valve Core Lock Nut (Jam) Protective Cap Valve Cap Lock Nut Outer Spacer Anti-Extrusion Ring Ass’y. 0870445150 0870485150 0870455150 0870475150 0870465150 5000 PSI . 0850695050 0856665050 0850705050 0851055050 0851045050 10 Gal.4. **Contains items 2.15 Gal.7. 0870445025 0870485025 0870455025 0870475025 0870465025 5 Gal.Ref. 10 ft. 25 & 26.01 . In. 703026 703028 703029 703030 703032 25 Gal. 10 .▲ Pressure 3000 PSI 3000 PSI 3000 PSI 5000 PSI Buna-Nitrile -01 NA L074210001 L074400001 L074400001 Seal Type Butyl Fluorocarbon EPR -06 -28 -08 NA NA NA L074210003 L074210005 L074210007 L074400003 L074400005 L074400007 L074400003 L074400005 L074400007 Hydrin -04 NA L074210009 L074400009 L074400009 162 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Figure D and contains items 2.15 Gal. B & C. 10-15 in. 3-4 in. 25 & 26* 10 C. 21/2 Gal. lbs. 0850693CI0 0850693001 0850693002 0850693006 0850693010 0850693025 0850693050 0850693100 0850693110 0850693150 0850693250 0850693400 0870445025 0870445050 0870445100 0870445150 0850695010 0861905025 0861905050 0861905100 0861905150 0850695025 0850695050 0850695100 0850695150 0850703CI0 0850703001 0850703002 0850703006 0850703010 0850703025 0850703050 0850703100 0850703110 0850703150 0850703250 0850703400 0870465025 0870465050 0870465100 0870465150 0850705010 0861915025 0861915050 0861915100 0861915150 0850705025 0850705050 0850705100 0850705150 0851043CI0 0851043001 0851043002 0851043006 0851043010 0851043025 0851043050 0851043100 0851043110 0851043150 0851043250 0851043400 0870465025 0870465050 0870465100 0870465150 0851045010 0861925025 0861925050 0861925100 0861925150 0851045025 0851045050 0851045100 0851045150 0851053CI0 0851053001 0851053002 0851053006 0851053010 0851053025 0851053050 0851053100 0851053110 0851053150 0851053250 0851053400 0870475025 0870475050 0870475100 0870467150 0851055010 0861935025 0861935050 0861935100 0861935150 0851055025 0851055050 0851055100 0851055150 0856663C10 0856663001 0856663002 0856663006 0856663010 0856663025 0856663050 0856663100 0856663110 0856663150 0856663250 0856663400 0870485025 0870485050 0870485100 0870487150 0856665010 0861945025 0861945050 0861945100 0861945150 0856665025 0856665050 0856665100 0856665150 5000 PSI—Ref. 4.150 C.) Lock Nut Outer (1 gal.Catalog HY10-1630/US Bladder Accumulators (Parker) Accumulator Parts Description 6 5 Hydraulic Accumulators Maintenance Instructions 6 5 4 3 25 7 25 26 11 11 14 1 19 18 20 15 14 1 19 18 20 15 24 2 2 1 28 30 6 5 7 25 26 6 5 7 25 26 1 2 6 5 4 1 5 4 3 1 2 3 25 26 1 2 26 24 2 FIGURE A 3000 PSI 10 CI -150 CI Item No. 15 Gal. Seal Type Butyl Fluorocarbon EPR -06 -28 -08 NA NA NA L074210003 L074210005 L074210007 L074400003 L074400005 L074400007 L074400003 L074400005 L074400007 Gas Valve Assembly Part Numbers Size † Contains items 3. 4. 21/2 Gal. 15 Gal. O-ring O-ring Back-up O-ring Back-up Metal Top Adapter Gas Valve O-ring (Gas Valve) Back-up Washer (Stem) O-ring (Stem) Bladder Assembly Part Numbers Seal Type Accumulator -01 -06 -28 -08 -04 Size Buna Butyl Fluorocarbon EPR Hydrin 3000 PSI – Standard – Ref. 5 Gal. ▲ Contains items 7. 18. 25 & 26. lbs.▲ 1 . lbs.) Gas Valve Cap 14 ft. 25 Gal. lbs. 73 ft. 1 pt. 20. 10 Gal. * See following page for items 18-20. ***Contains items 2. 5 Gal. 5000 PSI — Ref. 1 2 3 4 5 6 7 11 14 15 18 19 20 24 25 26 28 30 FIGURE B 3000 PSI 1-15 GALLON FIGURE C 3000 PSI CONVENTIONAL TOP REPAIRABLE FIGURE D 5000 PSI CONVENTIONAL TOP REPAIRABLE FIGURE E 5000 PSI 2" VALVE STEM FIGURE F 5000 PSI Description Shell Bladder O-ring Valve Core Lock Nut (Jam) Protective Cap Valve Cap Lock Nut Outer Spacer Anti-Extrusion Ring Ass’y.15 Gal.† 25 . 4.I. 3. 5 Gal. 10 Gal. lbs. **Contains items 2. lbs. 26. lbs. 28 & 30 Suggested Approximate Torque Values Protective Cap Lock Nut (Jam) Valve Core Bleeder Plug Lock Nut Outer (1 qt. Contains items 2.▲ Pressure 3000 PSI 3000 PSI 3000 PSI 5000 PSI Buna-Nitrile -01 NA L074210001 L074400001 L074400001 Hydrin -04 NA L074210009 L074400009 L074400009 163 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 25. 1 Gal. & 26 5000 PSI — 2" Valve Stem Ref. 10 . 10 Gal. 19. 11 Gal. 7. 2½ Gal. 15 Gal. 7.I. 25 & 26. 3.** 150 C. 3 & 4 as shown in Figure A.40 Gal. 1 Gal. 1 qt. 18. 19. Figure E Contains Items 2.*** 21/2 Gal. 25. 200 ft. 56 ft. 1 . Illinois USA Maint. lbs. 25 & 26 NOTE: Items shaded in gray will be phased out. 5 Gal. 10 ft.) Lock Nut Outer (21/2-15 g. Figures A. 7.I. 15 Gal. 25 & 26. 275 ft. 10 Gal. Figure F Contains Items 2. 40 Gal. . Core Tool—The core tool is used to remove and reinstall the valve core. 085109 0250 085109 0500 085109 1000 085109 1500 582441 0000 300987 085110 0000 * Oil Port Assembly contains items 10 through 23. 1 Pt. 21/2 .) Oil Service * = “S” Water/Chem. Used to remove hydraulic poppet assembly from accumulator shell. The pull rods attach to the gas valve of the bladder for ease of assembly into shell during reassembly. . 13. *** Bleeder Plug for SAE straight thread port assemblies will also contain an o-ring (Item 27). .Qt.Qt. Illinois USA . 17. ** Port & Poppet Assembly contains items 10. In. 22 & 23. 21/2 . 1 Gal.15 Gal. Bladder Pull Rods—(Bladder Type Accumulator) Pull Rods are available in single or multiple lengths for different size accumulators. 12. 10 Cu. Port /4" NPT . In. 1 Pt. In.15 Gal. In. 1 8* 9** 10 11 12 13 14 15 16 17 18 19 20 22*** 23 27 Description Shell Oil Port Assembly Poppet & Plug Assembly Oil Port (Machined) Lock Nut Outer Valve Poppet Piston Poppet Spacer Anti-Extrusion Ring Assembly Elastic Stop Nut Spring Poppet O-ring O-ring Back-up O-ring Back-up Metal Bleeder Plug Dust Cap Oil Port O-Ring (SAE Bleed Plug) Accumulator Accessories Description Pull Rod (1 Qt-21/2 Gal) Pull Rod (5 Gal) Pull Rod (10-11 Gal) Pull Rod (15 Gal) Core Repair Tool Core Installation Tool Spanner Wrench Part No. 150 Cu. It is also used to ream valve seat and repair threads. Spanner Wrench—Fits all standard size bladder accumulators. Accumulator Repair Tools 1. 3. 21/2 . Service 164 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.15 Gal. Oil Port Assembly Part Numbers 3000 PSI Accumulators Accumulator Size 10 Cu. 1 Gal. 16. 1 Gal.Catalog HY10-1630/US Bladder Accumulators Hydraulic Accumulators Maintenance Instructions Accumulator Parts Description Item No.Male SAE #8 3 /4" NPT SAE #12 1" NPT SAE #16 11/4" NPT SAE #20 11/4" SAE Split Flange 2" NPT SAE #24 2" SAE Split Flange 11/4" NPT 3 Seal Type -01 Buna-Nitrile L076741*01 L076741*02 L075031*01 L075031*02 L074151*01 L074151*02 L074161*01 L074161*02 L074161*03 L074171*01 L074171*02 L074171*03 L074171*04 -04 Hydrin L076749*01 L076749*02 L075039*01 L075039*02 L074159*01 L074159*02 L074169*01 L074169*02 L074169*03 L074179*01 L074179*02 L074179*03 L074179*04 -06 Butyl L076743*01 L076743*02 L075033*01 L075033*02 L074153*01 L074153*02 L074163*01 L074163*02 L074163*03 L074173*01 L074173*02 L074173*03 L074173*04 -08 EPR L076747*01 L076747*02 L075037*01 L075037*02 L074157*01 L074157*02 L074167*01 L074167*02 L074167*03 L074177*01 L074177*02 L074177*03 L074177*04 -28 Fluorocarbon L076745*01 L076745*02 L075035*01 L075035*02 L074155*01 L074155*02 L074165*01 L074165*02 L074165*03 L074175*01 L074175*02 L074175*03 L074175*04 Port & Poppet Assemblies L076740*01 L076740*02 L075030*01 L075030*02 L074350*01 L074350*02 L074360*01 L074360*02 L074360*03 L074370*01 L074370*02 L074370*03 L074370*04 * = “0” (Std. 150 Cu. 21/2 .15 Gal. 2. . Units under 1 liter in gas capacity are designed and manufactured in accordance with Sound Engineering Practice (S. The Directive requires that all pressure equipment and assemblies within its scope must be safe when placed on the market and put into service. when properly installed and maintained and used for their intended purpose. domestic animals and property. Such units do not bear the CE Marking. Units 1 liter and greater in gas capacity can be identified by a CE Marking place on the product label attached to the accumulator. The purpose of the PED is to harmonise national laws of member states regarding the design. simple pressure vessels. which were identified by the European Community's program for the elimination of technical barriers to trade. Safe pressure equipment and assemblies are defined as those which. manufacture. The Pressure Equipment Directive provides for a flexible regulatory environment which does not impose any technical solution. gas applicances etc. where appropriate..E. testing and conformity assessment of pressure equipment and assemblies of pressure equipement. 165 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.CE Marking What is the Pressure Equipment Directive? The Pressure Equipment Directive (PED) is one of the series of technical harmonisation directives covering subjects such as machinery. Illinois USA Maint.P. The program aims to ensure the free placing on the market and putting into service of relevant equipment within the European Union and the European Economic Area.) in order to ensure safe use.Catalog HY10-1630/US Bladder Accumulators – CE Marking Hydraulic Accumulators Maintenance Instructions Hydraulic Bladder Accumulators . will not endanger the health and safety of persons and. should be designed so that it automatically discharges all hydraulic fluid from the accumulator when the equipment is turned off. If a check valve prevents flow back to the pressure source (pump). Keep the hydraulic port covered to keep out foreign material until ready to make the hydraulic connections. Illinois USA . The accumulator should be mounted within 25° of vertical with the hydraulic port on the bottom. It should also be rigidly mounted using appropriate mounting hardware. which is shown in the Accumulator Accessories section of this catalog. However. which contains a connection to the accumulator. in some cases they will be shipped with some amount of nitrogen charge. gauge control port. a shut-off device is not required for safety reasons but may be appropriate for service and maintenance. Safety components may be connected by lines and/or installed in a safety block. 166 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. manually operated shut-off device. pressure release device and return line to the reservoir. The hydraulic circuit. Example 2 Configuration with additional pressure release device which opens automatically in the case of circuit break down. Example 1 Basic safety equipment for a single accumulator with permanently connected safety valve and gauge. the value of which will be stamped on the nameplate. The accumulator must always be protected with sufficient discharge capacity.Catalog HY10-1630/US Bladder Accumulators – CE Marking Installation Hydraulic Accumulators Maintenance Instructions Most accumulators shipped from the factory carry a nominal pre-charge. Example 4 The above configuration shows a group of several accumulators connected with a single pressure line which is permanently connected with a gauge and a safety valve. The safety valve is permanently communicating with the pressure line.Catalog HY10-1630/US Bladder Accumulators – CE Marking Hydraulic Accumulators Maintenance Instructions Example 3 Configuration with a 3/2-way-directional-control which simultaneously serves to isolate the accumulator from the presure line and release pressure to the return line. The accumulator is either protected by the safety valve or connected to the return line. Each individual accumulator may be isolated from the pressure line by a shut-off device and released by a pressure device to a return line for maintenance purposes. therefore also protecting the circuit. An external control gauge connected to a quick coupling allows observation of the pressure at the fluid port of each individual accumulator. . 167 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA Maint. the return line. Safety equipment for filling procedures is not shown. 168 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. pressure release device and ports for the pressure line. Illinois USA . control gauge and the accumulator itself. Each safety block includes a safety valve. Example 6 Configuration for a transfer type accumulator with additional gas bottles. This configuration meets all safety requirements even for several pressure sources.Catalog HY10-1630/US Bladder Accumulators – CE Marking Example 5 Hydraulic Accumulators Maintenance Instructions Configuration similar to example 1 but with serveral accumulators each equipped with a safety block. shut-off device. gauge. which appear on the bladder surface as cracks. Bladder Storage The shelf life of bladders under normal storage conditions is 1 year.Catalog HY10-1630/US Bladder Accumulators – CE Marking Accumulator Sizing and Selection Software Hydraulic Accumulators Maintenance Instructions Parker offers leading edge application assistance. Normal storage condition consists of the bladder being heat sealed in a black plastic bag and placed in a cool dry place away from sun. ultraviolet and fluorescent light that can cause the bladder to weather check and dry rot. Temperature ranges may vary depending upon fluid used in hydraulic system. not the accumulator. . Accumulator Seals Bladder accumulators are available for use with many operating medias. However. Water & Chemical Service Option (W) Bladder accumulators are available with a water and chemical resistance options. if the storage conditions are improved.com/accumulator for more information. Extended life can be achieved by having the bladder charged with nitrogen to its full size. this period can be extended to 2 years.) Butyl Ethylene Propylene Fluorocarbon Elastomer General Application and Compatibility* Parker's Standard Compound . Fluid should be a non-dangerous liquid as well as precharged with an inert gas such as nitrogen. Available seal compounds are shown in the table below: **Recommended Operating Temperature Range -20ºF to 200ºF -29ºC to 93ºC -40ºF to 225ºF -40ºC to 107ºC -40ºF to 200ºF -40ºC to 93ºC -40ºF to 200ºF -40ºC to 121ºC -10ºF to 250ºF -23ºC to 121ºC Maximum Temperature with Reduced Life 225ºF 107ºC 250ºF 121ºC 300ºF 149ºC 300ºF 149ºC 400ºF 204ºC Seal Code 01 04 06 08 28 Polymer BunaNitrile Hydrin (Lo-Temp. The (W) designation includes an internally Skotchkoted shell and stainless steel port assembly. Consult factory for details. sealed and kept in a cool and dry place away from sunlight and ozone producing equipment.parker. The Skotchkote offers added protection against more corrosive fluids. The air in the plastic bag shall be purged using nitrogen prior to sealing. ** The temperature listed indicates the operating temperature range of the seals. For further product application assistance.Compatible with most mineral oil-based fluids Compatible with most mineral oil-based fluids with enhanced low temperature performance Compatible with most phosphate ester fluids and some synthetic fluids Compatible with some synthetic fluids and water Compatible with most mineral oil-based fluids at higher temperatures and some exotic fluids *Note: Consult local distributor or factory for fluid compatibility information. and placing it in a heat sealed 5 mil thick black plastic bag. The bag must then be placed in an appropriate size cardboard box. in the form of the InPHorm Accumulator Sizing and Selection Software or visit www. 169 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. contact Parker's Accumulator Technical Support Group at (815) 636-4100. Illinois USA Maint. Base Bracket Assembly for Bladder Accumulators Accumulator Models Bladder Size 1 Gal. (3K) 2-1/2 .15 Gal.65 x .35 3.3 10.00 B 3.3 B 7. 3/8-16 1/2-13 5/8-11 5/8-11 Bladder-Type Accumulator Bladder-type accumulators should be mounted vertically with the hydraulic port down.4 3.87 F 3.87 0.29 2. CAUTION: Bladder-type accumulators should never be mounted more than 25° angle from the vertical.25 / 2.62 3.41 5.75 6.62 H 1.85 3. Part Number and Dimensions "U" Bolt Part Number 0862090000 0854380000 0854390000 0853360000 Wt. Lbs.50 / 3. 8700110238 8700110358 A 4.15 Gal.) 0.28 170 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.58 2.84 D 4.58 H 0.62 4.0 A 1/2 1/2 5/8 5/8 B 3-11/16 4-5/8 6-3/4 9.94 Dimensions C D 4. (3K) Part Number and Dimensions Base Bracket Assembly Part Number 1449100000 1448720000 Wt. 5 5 A 10.Catalog HY10-1630/US Bladder Accumulators – CE Marking Hydraulic Accumulators Maintenance Instructions “U” Bolts for Piston & Bladder-Type Accumulators Accumulator Models (3000 PSI) Bladder Size 1 Pint 1 Quart 1 Gallon 2-1/2 .58 1.85 G 1. (lbs.75 E 8.9 1.65 x .87 8.87 Clamp Brackets for Small Bladder Accumulators Bladder Size Cubic Inches 10 30 Part No.2 2.25 5.87 7.87 C 3.0 C 4-1/16 5-1/8 7 9-5/8 D 3-5/8 4-1/2 6-1/8 7-1/8 E 2 3 3-3/4 3-3/4 Thrd. Illinois USA . 6 10.5 Figure A Figure B Notes: 171 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5 7. Illinois USA Maint.5 B 3.6 3.Catalog HY10-1630/US Bladder Accumulators – CE Marking Hydraulic Accumulators Maintenance Instructions Clamp Brackets for Bladder-Type Accumulators Bladder Size 1 Qt.5 Dimensions D Max.7 12. 6.5 8.50 x .5 11. 1.0 9.8 2.2 1.8 5.2 1.15 Gal.3 8.I.51 .6 4.5 6. (3K) (Figure B) 2-1/2 . 1466230000 1449080000 1449070000 1349200000 A 4.75 . (Figure A) 2-1/2 .50 x .2 Wt.51 .0 E 2.0 10.4 F . (Figure A) 1 Gal.. (5K) (Figure B) Clamp Part No.35 x .7 4. .35 x .5 C Max.3 8.15 Gal.8 9.9 6. 5. 150 C.2 4.75 G 1.2 1. Lbs. as it will damage the valve core. (C) Close bleed valve. (B) Back gas chuck “T” handle all the way out (counterclockwise) before attaching charging assembly to accumulator gas valve.000 PSI ACCUMULATORS † “XX” Denotes to gauge pressure. lbs. use assembly shown in Figure 6 . tighten hex nut at point “D” to close internal poppet (5-8 ft. follow steps A through L and skip steps E and I. 3. left-hand thread). precharge is usually set at about 65% of system pressure. make sure it is compatible with the gas valve assembly and nitrogen source. then slowly open bleed valve. (Note: It is recommended that precharge pressure be at least 25% of maximum system pressure. (H) Let the precharge set for 10 to 15 minutes. lbs. follow steps A through L and skip steps F and J. All components must be rated for a pressure at least as high as the nitrogen source. (G) Crack open nitrogen bottle or regulator valve and slowly fill accumulator. precharge is usually set at approximately 90% of minimum system pressure. and in Figure 4 Part †10871XX0000 for 1-15 gallon & Part †1087102XX00 for 10-150 cu.5-17 cm kg) and valve guard. (J) For gas valves as shown in Figure 9. hold gas valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench. turn “T” handle all the way out on gas chuck. It is strongly recommended that the nitrogen bottle used have the appropriate pressure high pressure regulator (not included). If accumulator has a gas valve as shown in Figure 8A or 8B.) Damage to bladder may occur if this ratio is not maintained or exceeded. Attach hose to nitrogen bottle. Standards: Nitrogen gas bottles for water pumped nitrogen has a right-hand valve thread which requires charging and gauging assembly †1144595XX00 for units up to 3000 psi. IN.2 cm kg). Note: Three (3) turns will fully open the valve.5-17 cm kg). with a wrench.000 psi. Do not turn the “T” handle all the way down.) CAN BE USED ON BOTTOM AND TOP REPAIRABLE 3. If the desired precharge is exceeded. right-hand thread.) FIGURE 1 PART #144595 XX00 FIGURE 2 PART #085122 XX00 CAN BE USED ON 3. This will allow the gas temperature to stabilize. lb. Do not reduce precharge by depressing valve core with a foreign object. IN. remove assembly. attach swivel nut to gas valve and tighten (10-15 in. as well as the 25-40 gallon. (L) Replace gas valve cap (10-15 in.) PART #087103 XX00 (10-150 CU. the bladder may suffer permanent damage.) (11. 172 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. accumulator rated for 3.A. For shock suppression applications.) (11. FIGURE 4 PART #087100 XX00 (1-15 GAL. High pressure may rupture rubber valve seat. If water pumped nitrogen is not available. oil-pumped nitrogen may be used.N. Caution: If the precharge is not done slowly. (For accumulators rated for 5. Check for precharge leak using a common leak reactant. Make sure nitrogen supply is shut off. (F) For gas valves as shown in Figure 9.Part †1144912XX00). When the accumulator is used to supplement pump flow. If other equipment is used. Part †1144596XX00.000 PSI BOTTOM REPAIRABLE BLADDER ACCUMULATORS FIGURE 3 VALVE EXTENSION P. Accumulators having gas valve per Figure 8A or 8B (A) Remove gas valve guard and gas valve cap. Hydraulic Accumulators Maintenance Instructions (I) When finished precharging accumulator. then open bleed valve. 0854340000 FOR USE ON CONVENTIONAL TOP REPAIRABLE UNITS IN CONJUNCTION WITH FIGURES 1 OR 2 NOTE: For top repairable units having valves as shown in Figure 8B. This will open the poppet inside the gas valve. (E) Turn gas chuck “T” handle until the gauge starts showing the pressure in the accumulator. If accumulator has a gas valve as shown in Figure 9. (C. auxiliary power supply or leakage compensation. a valve extension as shown in Figure 3 must be attached to the gas valve after removing valve cap. close nitrogen bottle valve. It is recommended to use charging and gauging assembly as shown in Figure 1 (Part †1144595XX00.79.000 psi or less.) PART #087102 XX00 (10-150 CU.) (5. Illinois USA . Shut off when gauge indicates 100 psi above desired precharge. (Gas valve cap serves as a secondary seal. (K) Hold gas valve to keep from turning.Catalog HY10-1630/US Bladder Accumulators – CE Marking Pre-Charging Use only an inert gas such as nitrogen for precharging piston accumulators. Oil-pumped nitrogen requires a left-handed valve thread (use †1144596XX00). Do not use oxygen or shop air.000 psi accumulators. in. (D) Making sure not to loop or twist the hose.G.) FIGURE 5 PART #087101 XX00 (1-15 GAL. loosen swivel nut. check pre-charge once during first week to see that no leak has developed.) Part Number 085434 XX00 Valve Extension for 3000 PSI Contains extension and valve core. 25 .5-17 cm kg) and valve guard. remove accumulator from system and replace faulty components. Wait until all the gas pressure has been released.) (11. (4) (5) Turn “T” handle down 2 turns to depress core in gas valve and check pressure. Hydraulic Accumulators Maintenance Instructions For accumulators rated for 5000 psi. use gaging assembly in Figure 7 (Part #871372XX00) and follow steps 8 through 14.) (29-35 cm kg) when using gauging assembly in Figure 4. check gas valve for leakage and recharge. then install cap on gas valve (10-15 in. If there is no gas in bladder and fluid appears at gas valve. lb. (3b) Install gas valve o-ring on the gas valve.15 gallon. (6) (7) FIGURE 6 PART #870810 XX00 FIGURE 7 PART #871372 XX00 25-40 GALLON 3000 PSI AND 5000 PSI RATED UNITS EQUIPPED WITH MS GAS VALVE AS SHOWN IN FIGURE 9.5-17 cm kg). tighten all connections. hold gas valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench. after removing valve cap. FIGURE 8A FIGURE 8B 3000 PSI VALVES FIGURE 9 5000 PSI VALVES Maintenance Little maintenance is required for a bladder accumulator. To remove gauging assembly. This will open the poppet inside the gas valve.5-17 cm kg). Accumulators rated for 5000 psi will have a gas valve as shown in Figure 9. 3000 PSI RATED UNITS Accumulators rated for 3000 psi will have a gas valve as shown in Figure 8A or 8B. check pre-charge monthly. and attach gauging assembly to valve stem.150 cubic inch. 3000 & 5000 PSI Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings (1. lb.035-14 NGO female) adapter incorporating gas valve bleeder valve and gas chuck (less gauge). Gauging Assembly for 3000 PSI Top Repairable Gauging device consisting of adapter incorporating gas valve bleeder valve and gas chuck (less gauge). Open bleed valve and release all the gas pressure. If leakage continues. lb. Hold gas valve from turning. either use gaging assembly in Figure 2 (Part #085122XX00) or gaging assembly in Figure 5 (Part #087101XX00) and follow Steps 1 through 7. discharge all oil from accumulator. remove valve core.) Remove accumulator from hydraulic system. Detach gauging assembly and. Illinois USA Maint. attach gaging assembly (Part #085122XX00) or (Part #087103XX00)for 10 . lb. 173 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. and (Part #087101XX00) for 1 . Remove gas valve guard and gas valve cap.) (11. loosen swivel nut and remove assembly. Note.40 GALLON 3000 PSI AND ALL 5000 PSI UNITS Part Number 870810 XX00 Charging and Gauging Assembly for 25-40 Gal.) (11. Gauging Assembly for 5000 PSI Gauging device consisting of adapter incorporating gas valve bleeder valve and gas chuck (less gauge). lb. (12) With wrench. (8) Remove gas valve guard and gas valve cap. Check pre-charge pressure. For accumulators rated for 3000 psi. four (4) turns will fully open poppet.) 087100 XX00 (1-15 gal. If pre-charge is low. (10) Attach gauging assembly to gas valve and tighten swivel nut (10-15 in. hold valve at point “C” with one (1) wrench while unscrewing hex nut at point “D” with a second wrench until gas begins to escape through the top of the valve. Pre-charge Checking Procedure Using appropriate valve in the hydraulic system. tighten hex nut at point “D” to close internal poppet (10-15 in. (Caution: Keep face away from gas valve as the high pressure nitrogen is discharging. using valve core removing tool (Part #582441XX00).) Part Number 085122 XX00 (2) (3a) Attach gauging assembly to gas valve or to gas valve extension and tighten swivel nut (10-15 in. Tighten assembly (25-30 in. For these units. Check pre-charge if the system is acting sluggish.) (11. Part Number 087101 XX00 (2. For these units. For left-hand thread nitrogen bottle fitting specify part number 144596 0000. 25-40 GALLON 3000 PSI AND 5000 PSI RATED UNITS EQUIPPED WITH MS GAS VALVE AS SHOWN IN FIGURE 9.) (11. (For top repairable unit connect valve extension Part #085434XX00) as shown in Figure 3 and tighten with wrench. 3000 PSI RATED UNITS (1) Remove gas valve guard. remove valve extension.Catalog HY10-1630/US Bladder Accumulators – CE Marking Part Number 144595 XX00 (Std) (Right Hand) Charging and Gauging Assembly for 3000 PSI Bottom Repairable Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings adapter incorporating gas valve bleeder valve and gas chuck (less gauge).5 . After original installation.5-17 cm kg). Close bleed valve and turn “T” handle all the way out. unit must be removed and bladder replaced.15 gal. Remove accumulator from hydraulic system. lb. (13) Hold gas valve at point “C” with a wrench and remove swivel nut assembly. .5-17 cm kg) and install gas valve guard. Charging and Gauging Assembly for 3000 PSI Bottom & Top Repairable Charging and Gauging Assembly consists of 10' charging hose with standard right-hand thread nitrogen fittings adapter incorporating gas valve bleeder valve and gas chuck (less gauge). (9) Close bleed valve. If necessary. Thereafter. POINT “D” VALVE CORE POINT “C” VALVE CORE ACCUMULATOR (11) Referring to Figure 9. Part Number 087102 XX00 (10-150 cu. (14) Replace cap on gas valve (10-15 in. If there is external leakage. when using gauging assembly in Figure 1. Gauging Assembly for 3000 PSI Bottom Repairable Gauging device consisting of adapter incorporating gas valve bleeder valve and gas chuck including gauge. in. turn “T” handle all the way out and then open bleeder valve. Part Number 871372 XX00 Removal of Accumulator From Hydraulic System Shut equipment down and make certain that hydraulic pressure at the accumulator is at zero. Once the bladder valve stem has been pulled through the valve stem opening in the shell. Remove jam nut from bladder gas valve stem using a 1-5/16" socket wrench. If parts are pitted. Clean & Inspect Cleaning: All metal parts should be cleaned with a cleaning agent. If this area is pitted consult factory.Catalog HY10-1630/US Bladder Accumulators – CE Marking Disassembly of Bottom Repairable Accumulators Figure 1. 4. Figure 8. 2. (See Removal of FIGURE 10 Accumulator from System). check the poppet plunger to see that it spins freely and functions properly. 5. After shell has been cleaned and inspected. Once the valve stem nut is in place. install FIGURE 9 the valve stem nut by hand. clean with commercial rust remover. 2. Shell: After shell has been cleaned with a cleansing agent. With all gas completely exhausted from bladder. replace accumulator shell in vise or on table. discard bladder. remove lock nut from the hydraulic port assembly. collapse bladder and fold longitudinally in a compact roll. Insert hand into the accumulator shell and remove the o-ring backup. Figure 5. deflate bladder immediately. Remove bleeder plug (if the accumulator is equipped with one) on hydraulic port assembly. Figure 6. Fold anti-extrusion ring to enable removal of anti-extrusion ring from shell. If soap solution bubbles. Hydraulic Accumulators Maintenance Instructions Hydraulic Port: Inspect assembly for damage. Figure 2. the accumulator body should be secured in a vise. FIGURE 1 Seals: Check anti-extrusion ring and soft seals for damage and wear. Using a spanner wrench. If rust is detected. Figure 7. o-ring. Figure 9. preferably a chain vise. Once the accumulator has been removed from the equipment. FIGURE 2 Reassembly of Bottom Repairable Accumulators 1. 6. Secure valve FIGURE 5 stem from twisting with an appropriate wrench applied to the valve stem flats. then push the hydraulic port assembly into the shell prior to Step 4. Insert the bladder pull rod through the valve stem opening and through the shell fluid port. Figure 3. Make sure the entire internal of the shell is lubricated. Special attention should be given to the area where the gas valve and hydraulic assembly pass through the shell. Fold bladder and pull out of accumulator shell. use an adjustable wrench on the flats located on the port assembly to prevent port assembly from rotatFIGURE 3 ing. 3. Wash bladder with a soap solution. replace with new components. Remove spacer. replace all worn or damaged seals with original equipment seals from the Hydraulic Accumulator Division. Remove hydraulic port plug from accumulator shell. replace with new components. hold with a cloth. check the inside and outside of shell. check assembly for rust and/or defective plating. With one hand. attach the bladder pull rod to the bladder valve stem. 174 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. If a standard jaw vise is used. Make sure the gas is relieved from the accumulator. If bladder is slippery. remove the bladder pull rod. 1. If protective plating is damaged. brass inserts should be used to protect the accumulator hydraulic port assembly from damage. Remove jam nut from bladder valve stem. Slight twisting of bladder will assist in this insertion. In cases where the accumulator is used with water. Spray the inside of the accumulator shell with a liberal amount of clean system fluid to lubricate and cushion bladder. Any nicks or damages in this area could destroy the accumulator bladder or damge new seals. Bladder: Inflate bladder to normal size. metal FIGURE 4 backup. Clamp on wrench flats only when using a jaw vise to prevent accumulator from turning. Figure 4. FIGURE 6 Disassembly of Conventional Top-Repairable Accumulators The conventional toprepairable accumulator PROTECTIVE GAS END CAP ADAPTER uses a gas-end adapter 1-5/16" HEX NUT which is retained in the OUTER shell with an anti-extrusion LOCKNUT ring exactly like those ANTIEXTRUSION used in port assemblies RING (see Figure 10). Seals and FIGURE 7 soft parts should be wiped clean. Illinois USA . A slight twisting motion while pulling on the bladder reduces effort required to remove bladder from shell. Seperate the antiextrusion ring from the hydraulic port. After testing. pull the bladder pull rod while FIGURE 8 feeding the bladder into the shell with the other hand. Special attention should be given to the area where the gas valve and hydraulic assembly pass through the shell. NOTE: Conventional top repairable accumulators may be repaired by removing the bladder from either the hydraulic end or the gas end of the accumulator. Insert gas end adapter. Insert hand into accumulator. Insert spacer with the smaller diameter of the shoulder facing the accumulator shell. With all air completely exhausted from bladder. Illinois USA Maint. check the poppet plunger to see that it spins freely and functions properly. After testing. place the anti-extrusion ring on the hydraulic port assembly with the steel collar facing toward the shell fluid port.Catalog HY10-1630/US Bladder Accumulators – CE Marking 3. Hydraulic Accumulators Maintenance Instructions Hydraulic Port Assembly Installation 1. check the inside and outside of shell. 3. o-ring and metal back-up. deflate bladder immediately. Figure 13. This will hold the gas end adapter in place. 10. Install o-ring backup over FIGURE 14 hydraulic port assembly and push until it bottoms against o-ring (1-40 gallon sizes and 5K only). Remove gas end adapter from shell. 9. Install the lock-nut on the poppet assembly and tighten securely. remove outer lock nut on the gas end adapter. install valve core into the bladder stem. Thread bleeder plug into the hydraulic port assembly. Install the outer spacer. 8. Remove bladder from shell. Reaching inside the accumulator. 12. Fold antiextrusion ring to enable insertion into the shell. If parts are pitted. Hydraulic Port: Inspect assembly for damage. Reassembly of Conventional Top-Repairable Accumulators 1. using dry nitrogen with sufficient pressure (approximately 40-50 psi) to hold hydraulic port assembly in place so both hands are free to continue with assembly. fill accumulator with approximately 50 PSI nitrogen. 7. Figure 12. 5. Pre-charge accumulator. 4. This will squeeze the o-ring into position. 8. 6. Holding the hydraulic port assembly by the threaded end. 2. 6. 5. Wash bladder with a soap solution. Position accumulator so that fluid (same fluid as used in the system) can be poured into the accumulator (add approximately 10% of the accumulator capacity). Using a spanner wrench. Clean & Inspect Cleaning: All metal parts should be cleaned with a cleaning agent. If soap solution bubbles. 8. Bladder: Inflate bladder to normal size. See Figure 4. Fold the anti-extrusion ring and remove from shell. Make sure the entire internal surface of the shell is lubricated. insert the gas end adapter through the anti-extrusion ring and pull into place. o-ring and o-ring backup. Insert bladder into accumulator shell. 12. . Fold anti-extrusion ring and place inside accumulator. 10. collapse bladder and fold longitudinally in a compact roll. Install metal backup washer over hydraulic port assembly and push into the shell fluid port FIGURE 13 to bottom it out on antiextrusion ring. 5. Lay complete assembly in side shell. remove the o-ring back-up. replace with new components. Push the gas end adapter complete with the bladder into the shell. Seals: Check anti-extrusion ring and soft seals for damage and wear. If these areas are pitted. 11. 7. insert the poppet end into the shell fluid port. CAUTION: Do not twist oring. Seals and soft parts should be wiped clean. 7. Pre-charge accumulator to desired pressure. The steel surface on anti-extrusion ring should face outward. 2. replace with new components. Install the metal backup. Shell: After shell has been cleaned with a cleansing agent. With port assembly firmly in place. consult factory. (See pre-charge instructions. If rust is detected. FIGURE 11 3. Figure 14. Install the gas end adapter on the bladder and secure with jam nut. Spray the inside of the accumulator shell with a liberal amount of clean system hydraulic fluid to lubricate and cushion the bladder. This fluid will act as a cushion when the accumulator is pre-charged with gas. Install the outer locknut. Install accumulator on machine. See precharge instructions. 11. If protective plating is damaged. 9. check assembly for rust and/or defective plating. Pull the threaded end of the hydraulic port assembly through the shell fluid port until it seats solidly into position on the shell fluid port opening. 6. In cases where the accumulator is used with water. Use appropriate wrench on flats of port assembly to insure the unit does not turn. Separate the anti-extrusion ring from the gas end adapter. discard bladder. Install o-ring over hydraulic port assembly and push it into the shell fluid port until it has bottomed out against washer.) 175 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 4. Slowly FIGURE 12 pressurize the bladder. Any nicks or damages in this area could destroy the accumulator bladder or damage new seals. Holding the gas end adapter in place. 4. clean with commercial rust remover. Figure 11. replace all worn or damaged seals with original equipment seals from the Accumulator Division. Once the anti-extrusion ring has cleared the fluid port opening. * See following page for items 18-20.I. 4.† † Contains items 3. 10 Gal. 11 Gal. Pressure 3000 PSI 3000 PSI Buna-Nitrile -01 NA L074210001 Seal Type Butyl Fluorocarbon EPR -06 -28 -08 NA NA NA L074210003 L074210005 L074210007 Hydrin -04 NA L074210009 176 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA .** 150 C. 1 Gal. 1 pt. 19. 5 Gal.150 C. lbs. 73 ft. 25 & 26* 10 C. Contains items 2. lbs.I. 3. 4. 275 ft. **Contains items 2. 1 . lbs.*** 21/2 Gal. 20. 15 Gal. 200 ft.) Gas Valve Cap 14 ft. lbs. Gas Valve Assembly Part Numbers Size 10 . O-ring O-ring Back-up O-ring Back-up Metal Top Adapter Gas Valve O-ring (Gas Valve) Back-up Washer (Stem) O-ring (Stem) Seal Type Accumulator Low Temp. Suggested Approximate Torque Values Protective Cap Lock Nut (Jam) Valve Core Bleeder Plug Lock Nut Outer (1 qt. Buna Butyl Fluorocarbon EPR Size Nitrile 3000 PSI – Standard – Ref.) Lock Nut Outer (1 gal. 3 & 4 as shown in Figure A. 10 ft.) Lock Nut Outer (21/2-15 g. 19. 0850693CI0 0850693001 0850693002 0850693006 0850693010 0850693025 0850693050 0850693100 0850693110 0850693150 0850703CI0 0850703001 0850703002 0850703006 0850703010 0850703025 0850703050 0850703100 0850703110 0850703150 0851043CI0 0851043001 0851043002 0851043006 0851043010 0851043025 0851043050 0851043100 0851043110 0851043150 0851053CI0 0851053001 0851053002 0851053006 0851053010 0851053025 0851053050 0851053100 0851053110 0851053150 0856663C10 0856663001 0856663002 0856663006 0856663010 0856663025 0856663050 0856663100 0856663110 0856663150 NOTE: Items shaded in gray will be phased out.Catalog HY10-1630/US Bladder Accumulators – CE Marking Hydraulic Accumulators Maintenance Instructions Figure A 3000 PSI 10 -150 CI Figure C 3000 PSI CONVENTIONAL TOP REPAIRABLE Figure B 3000 PSI 1-15 GALLON Bladder Assembly Part Numbers Item No. lbs. 1 2 3 4 5 6 7 11 14 15 18 19 20 24 25 26 28 30 Description Shell Bladder O-ring Valve Core Lock Nut (Jam) Protective Cap Valve Cap Lock Nut Outer Spacer Anti-Extrusion Ring Ass’y. 4. 3-4 in.15 Gal. 18. 25 & 26. ***Contains items 2. Figures A. 18. lbs. 3. 25 & 26. lbs. B & C.I. lbs. 1 qt. 56 ft. 10-15 in. 5 Liter Metric 33 x 2 4 Liter 1 1/4" BSPP 4 Liter SAE # 16 4 Liter 1 1/4" SAE Code 62 4 Liter Metric 42 x 2 10 . Oil Port Assembly Part Numbers 330 Bar Accumulators Accumulator Size Port 0. * Oil Port Assembly contains items 10 through 23.Catalog HY10-1630/US Bladder Accumulators – CE Marking Hydraulic Accumulators Maintenance Instructions Accumulator Parts Description Item No. Illinois USA Maint. 22 & 23. 085109 0250 085109 0500 085109 1000 085109 1500 582441 0000 300987 085110 0000 Accumulator Repair Tools 1. 17. Service -28 Port & Poppet Fluorocarbon Assembly L076740*01 L076740*02 L075030*01 L075030*02 E074350*02 E07435B*01 E07435M*01 E074360*02 E07436B*01 E074360*03 E07436M*01 E074370*02 E07437B*02 E074370*03 E07437M*01 177 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 2. 1 8* 9** 10 11 12 13 14 15 16 17 18 19 20 22 23 27*** Description Shell Oil Port Assembly Poppet & Plug Assembly Oil Port (Machined) Lock Nut Outer Valve Poppet Piston Poppet Spacer Anti-Extrusion Ring Assembly Elastic Stop Nut Spring Poppet O-ring O-ring Back-up O-ring Back-up Metal Bleeder Plug Dust Cap Oil Port O-Ring (SAE Bleed Plug) Accumulator Accessories Description Pull Rod (1 Qt-21/2 Gal) Pull Rod (5 Gal) Pull Rod (10-11 Gal) Pull Rod (15 Gal) Core Repair Tool Core Installation Tool Spanner Wrench Part No. Used to remove hydraulic poppet assembly from accumulator shell.50 Liter 2" BSPP 10 . Core Tool – The core tool is used to remove and reinstall the valve core. 12. The pull rods attach to the gas valve of the bladder for ease of assembly into shell during reassembly. 13. Spanner Wrench – Fits all standard size bladder accumulators.50 Liter SAE # 24 10 .5 . *** Bleeder Plug for SAE straight thread port assemblies will also contain an o-ring (Item 27).50 Liter 1 1/2" SAE Code 62 10 . Bladder Pull Rods – (Bladder Type Accumulator) Pull Rods are available in single or multiple lengths for different size accumulators.5 . 3.16 Liter SAE # 8 0. . ** Port & Poppet Assembly contains items 10.5 Liter 1" BSPP 2.5 Liter SAE # 16 2. 16.50 Liter Metric 48 x 2 * = “0” (Std.1 Liter 3/4" NPT 0.) Oil Service -01 Buna-Nitrile -04 Hydrin Seal Type -06 Butyl -08 EPR t l u s y n r o o t C ac F * = “S” Water/Chem. It is also used to ream valve seat and repair threads.16 Liter 3/4" NPT Male 0.1 Liter SAE # 12 2. 94 .31 1.91 . The temperature variation factor is determined by the temperature encountered during precharge versus the operating temperature expected in the system.14 1.22 1.89 .15 1.04 1.00 .83 .03 1.05 1.83 .20 1.96 .94 .82 .85 .12 1.04 1.22 1.88 .06 1.36 1.94 .31 1.84 .06 1.30 1.14 1.20 1.02 1.85 .24 1.93 .21 1.35 1.10 1. 1.89 .83 .19 1.86 .00 .09 1.14 1.83 .33 1.98 .88 .13 1.09 1.19 1.15 1.16 1.92 .07 1. Temperature During Precharge 30.Catalog HY10-1630/US Bladder Accumulators – CE Marking Hydraulic Accumulators Maintenance Instructions Temperature Variations Bulletin Temperature variation can seriously affect the precharge pressure of an accumulator.05 1. 1.84 . find the operating temperature of 130°F in the left hand.07 1. 1.87 .82 .94 .00 .93 .28 1. 1.81 100.23 1.08 1.17 1.21 1.88 .98 . 180. 1.87 .09 1.80 .87 140. 1.14 1. 80.37 1.91 .20 1.15 1.81 .18 1.97 .96 .08 1.02 1.98 .16 1.85 .98 .00 .03 1.05 1.13 1.20 1.92 .08 1.27 1. 70. 1.12 1. .00 Let’s assume the temperature during precharge is 70°F.18 1.97 .88 150.02 1.97 .92 .90 . 1.89 .32 1.17 1. 1.25 1.96 200.16 1.27 1.00 . in this case.90 .10 1.06 1.82 .10 1.88 .06 1.10 1.85 130.98 . 1.19 1. 60.97 . 150.90 .02 1.98 .90 .00 .93 .95 .94 .10 1.82 . and your desired precharge is 1000 psi.97 .95 .97 .11 1.02 1.18 1.76 .92 .04 1.77 .18 1.97 .84 .24 1.87 . 1.31 1. 30.17 1.14 1.87 .13 1.95 .10 1. 1.98 .93 180. 100.00 .12 1.91 170.10 1.93 .95 .07 1.82 .95 .29 1.98 .00 .91 .15 1.76 .15 1.05 1.91 .84 . 200. 178 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.79 .02 1.14 1.98 .78 . 120.91 .26 1.00 .29 1.06 1.75 .07 1.83 .06 1.95 . 220.11 1.02 1.81 .81 .92 .01 1.80 .22 1.06 1.89 .81 . 140.08 1.92 .12 1.00 .82 . decreasing temperature will decrease the precharge pressure.29 1.02 1.05 1.04 1.89 . 1.02 1.13 1.72 40.95 .21 1.20 1.96 .12 1.16 1.84 120.90 .00 .33 1.85 .86 .20 1.93 .10 1.77 .18 1.79 .78 .78 .95 . 1.08 1. 50.16 1.02 1.00 .91 .92 . 160.00 .90 to obtain the actual precharge pressure required – 900 psi.13 1. 130.25 1.94 190. 1.00 .12 1.74 50.03 1.96 .08 1. 40.10 1.27 1.95 .11 1.02 1.34 1.76 70.79 90.85 . the expected operating temperature is 130°F.00 .25 1.77 . conversely.05 1.14 1.88 .88 .83 .98 .86 .86 .16 1.97 .11 1.05 1.03 1.84 .79 .04 1.89 . 190.84 .90 .88 .88 .07 1.08 1. Multiply the desired precharge of 1000 psi by the temperature variation factor of .86 .93 .16 1.95 .97 210.03 1.79 .86 .05 1.98 .06 1. 1.02 1.98 .93 .13 1.04 1.24 1.04 1.87 . you need to factor in the temperature variation.24 1.11 1.99 .75 60.94 .93 .03 1.17 1.82 110.00 .78 80.80 . Extend lines from each value until they intersect to find the temperature variation factor. 1.02 1.02 1.94 .98 . vertical column.92 .98 .86 .96 .88 .02 1.02 1.91 .03 1.11 1.02 1. Illinois USA . In order to assure the accuracy of your accumulator precharge pressure.89 .03 1.91 .22 1.95 .00 .09 1. 90.08 1.00 .90 .85 .05 1. Find the charging temperature of 70°F in the top horizontal row.00 .04 1.24 1. 1.98 .04 1.06 1.75 .25 1.09 1. 170.94 .19 1.94 .97 .92 .12 1. 1. 110. 210.22 1.98 .95 .96 .99 220.73 .03 1. the precharge pressure increases.08 1.93 .18 1.94 .05 1.07 1.85 .74 .98 .92 .23 1.90.89 .07 1.09 1.91 .07 1. 1.05 1.90 160.97 .39 1.89 .12 1.02 1.28 1.26 1.80 .78 . Next. As the temperature increases.08 1. 075 to 2. . which is shown in the Accumulator Accessories section of this catalog.80 Liters Operating Pressures to 250 Bar Nitrile & Hydrin Diaphragms Installation Keep the hydraulic port covered to keep out foreign material until ready to make the hydraulic connection. The hydraulic circuit. which contains a connection to the accumulator. 179 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. should be designed so that it automatically discharges all hydraulic fluid from the accumulator when the equipment is turned off.Catalog HY10-1630/US Diaphragm Accumulators Hydraulic Accumulators Maintenance Instructions Series “AD” Diaphragm Accumulators ■ ■ ■ . The accumulator should be rigidly mounted using appropriate mounting hardware. Illinois USA Maint. (EE) Making sure not to loop or twist the hose. This will allow the gas temperature to stabilize. (HH) Let the pre-charge set for 1 to 2 minutes. Slowly open bleed valve (3) until the proper pressure is reached. Note: For the most accurate results. use a temperature/ precharge chart or program. (DD) Make sure the bleed valve (3) is closed and tight. Attach hose to nitrogen bottle. Note: To ensure the most accuracy. (CC) On the charging device back the gas chuck (2) “T” handle all the way out (counterclockwise) before attaching the chuck to the Diaphragm accumulator. (D) Making sure not to loop or twist the hose. then close the bleed valve (3). It is strongly recommended that the nitrogen bottle used have a high pressure regulator. Refer to Figure 2. then open the bleed valve (3) to release residual gas. (C) Close bleed valve (3). (H) Let the pre-charge set for 1 to 2 minutes. Shut off the nitrogen supply when the gauge indicates 110% of desired pre-charge. lubricate the shell and bladder by placing a small amount of system fluid in the oil port and rotate the accumulator a few times. (J) Holding the “T” handle (2) to keep from turning. (L) Replace protective cap. use a gauge where the middle 1/3 of the gauge range encompasses the final precharge pressure. (GG) Crack open nitrogen bottle valve and slowly fill the accumulator until the button is seated on the fluid port opening. Slowly open bleed valve (3) until the proper pressure is reached.Catalog HY10-1630/US Diaphragm Accumulators Pre-Charging Diaphragm Accumulators Use an inert gas such as nitrogen for pre-charging accumulators. skip steps A through J and follow steps AA through JJ. (II) When finished precharging. Note: To ensure the most accuracy. attach the Swivel Connector (5) to the charging device gas valve (4) and tighten. then the nitrogen supply may be fully opened. (KK) Install secondary seal (B) and valve guard (A).G. Oil-pumped nitrogen requires a left-handed valve thread (use 8700430000). (JJ) Hold the gas valve from turning and remove the charging device. Hydraulic Accumulators Maintenance Instructions (K) Torque the Allen head screw to 14. (BB) Torque the gas valve to 9 ft-lbs + 1 (11. This action will depress the valve core. (10-15 in lbs (11. Before starting. Shut off the nitrogen supply when gauge movement stops and indicates 110% of desired pre-charge level.5 Nm + 1. Illinois USA . (B) Turn charging device “T” handle (2) all the way in (clockwise) before attaching charging assembly. (C. then open bleed valve (3) to bleed the residual pressure from the charging device. (AA) Remove gas valve guard (A) and secondary seal (B) from the accumulator. use a temperature/ precharge correction chart or program. turn the “T” handle (2) clockwise all the way. If accumulator has a gas valve as shown in Figure 5 follow steps A through K If accumulator has a gas valve as shown in Figure 6. (G) Crack open nitrogen bottle valve and slowly fill accumulator until the button is seated on the fluid port opening. Note: For the most accurate results.3). turn “T” handle (2) counterclockwise fully. (F) Turn “T” handle (2) in counterclockwise motion until rotation stops. make sure it is compatible with the gas valve assembly. 5 6 3 2 4 Figure 1 Precharging Diaphragm Accumulator having gas valve as per Figure 6. (E) Attach swivel nut (5) to gas valve (6) and tighten. Make sure nitrogen supply is shut off. 180 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Figure 5 Figure 6 Accumulator having gas valve as per Figure 5. loosen nut (4). Nitrogen source and all components must be rated for a pressure at least as high as the nitrogen source. If equipment other than the above listed is used. Refer to Figure 1.A. (I) When finished pre-charging accumulator. attach nut (4) to gas valve and tighten. This will allow the gas temperature to stabilize. use a gauge where the middle 1/3 of the gauge range encompasses the final precharge pressure.5 ft-lb +3 (20 Nm +5). standards: Nitrogen gas bottles for water pumped nitrogen has a right-hand valve thread which requires charging and gauging assembly 1486750000 for units up to 3600 psi. then the nitrogen supply may be fully opened. (A) Remove protective cover.5-17 cm kg)) (FF) Turn the “T” handle (2) clockwise all the way. oil-pumped nitrogen may be used. If water pumped nitrogen is not available. and remove the assembly from the accumulator. (A) Remove protective cover from accumulator. A B 2 3 Figure 4 Figure 6 3 2 4 Figure 3 181 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. (C) Close bleed valve (3). . then open bleed valve (3). Note: For the most accurate results. Illinois USA Maint.3 cm kg). use a temperature/ precharge chart or program. (H) Replace protective cap. Note: For the most accurate results. then open bleed valve (3) to bleed all residual pressure from the charging device. Using appropriate valve in the hydraulic system. remove the charging assembly from the accumulator. (G) Replace secondary seal (B) and protective cap (A). (F) Using a wrench to prevent the gas valve assembly from rotating. use a temperature/ precharge chart or program. (D) Turn “T” handle (2) in counterclockwise motion until rotation stops. Check torque on the gas valve to be 9 ft-lbs (10. Back gas chuck “T” handle (2) all the way out (counter clockwise). discharge all oil from accumulator and allow button to bottom against hydraulic port. Using appropriate valve in the hydraulic system. (A) Remove protective cover (A) and the secondary seal (B) from the Diaphragm accumulator. loosen nut (4). use a gauge where the middle 1/3 of the gauge range encompasses the final precharge pressure. (F) Hold “T” handle (2) to keep from turning. (C) Close bleed valve (3). in.Catalog HY10-1630/US Diaphragm Accumulators Hydraulic Accumulators Maintenance Instructions For diaphragm units having a gas valve configured like Figure 6 Caution use this procedure only if the accumulator volume is equal to or more than 30 cubic inches in gas volume. A B 4 5 3 2 Figure 6 Figure 2 Pre-charge Checking Procedure For diaphragm units having a gas valve configured like Figure 5 Caution use this procedure only if the accumulator volume is equal to or more than 30 cubic inches in gas volume. (E) When finished checking the precharge. Note: To ensure the most accuracy. (B) Refer to Figure 3.5-17 cm kg). For smaller volumes see the procedure for accumulators smaller than 30 cu.5 ft-lb + 3 (20 Nm + 9). Use precharge checking device P/N 0851220000 with gauge. Note: To ensure the most accuracy. discharge all oil from accumulator and allow button to bottom against hydraulic port. (G) Torque the Allen head screw to 14. (D) Turn “T” handle (2) in clockwise motion. remove the assembly from the accumulator. (E) When finished checking the precharge. use a gauge where the middle 1/3 of the gauge range encompasses the final precharge pressure. For smaller volumes see the procedure for accumulators smaller than 30 cubic inch capacity. (B) Refer to Figure 4. Turn the charging device “T” handle (2) all the way in (clockwise) attach charging and gauging head assembly by screwing mounting nut (4) to the gas end of the Diaphragm accumulator. attach charging and gauging head assembly by screwing the air chuck (2) to the valve stem of the Diaphragm accumulator and tighten (10-15 in lbs) (11. Use precharge checking device P/N 1480240000 with proper gauge. turn “T” handle (2) counterclockwise all the way. turn “T” handle (2) clockwise all the way. open bleed valve (3) until all gas pre-charge is relieved from accumulator. Then remove gauging assembly. This loss is attributable to the required gas volume filling the charging device thereby removing some volume from the accumulator. The accumulator is now safe to remove from the system. (B) Ensure that all fittings are tight and leakproof. (D) Stop pumping and allow the pressure to stabilize. The accumulator is now safe to remove from the system. If you wish to take a less accurate reading you may use the previously described methods. Illinois USA . For accumulators having gas valve as shown in Figure 6. Figure 7 182 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Using this method will prevent the loss of gas volume necessary to get a precharge reading when using standard gas port mounted devices. (C) Bring hydraulic pressure up until the precharge is exceeded. attach gauging assembly as shown in Figure 4 following Steps A through D.Catalog HY10-1630/US Diaphragm Accumulators To check the precharge on units having a gas volume of less than 30 cu in. Then remove gauging assembly. Then. Hydraulic Accumulators Maintenance Instructions Removal from Hydraulic System Shut the equipment down and make certain that hydraulic not pressure at the accumulator is at zero. (F) At the gauge reading where the slow decent stops and a rapid descent starts is the precharge pressure in the accumulator. This removal causes a precharge drop due to the volume in the accumulator being so small. (E) Slowly crack the needle valve open until you see a very slow drop in pressure on the gauge. You will know the precharge is exceeded when the resistance decreases and the gauge rise quickens. Using the setup shown below in Figure 7. take the following steps to check the precharge. but be sure to have a nitrogen supply available to replenish the gas that will be lost during the precharge check. For accumulators having gas valve as shown in Figure 5. Then. It is recommended that that the precharge be checked from the hydraulic port. (G) It is recommended to take multiple readings to ensure accuracy of the reading. attach gauging assembly as shown in Figure 3 following Steps A through D. open bleed valve (3) until all gas pre-charge is relieved from accumulator. included. (A) Connect the accumulator fluid port to the pump discharge line. Catalog HY10-1630/US Inline Pulse-Tone™ Hydraulic Accumulators Maintenance Instructions Pulse-Tone™ Inline Surge Suppressors SAE #6 183 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. . Illinois USA Maint. Since the Inline Pulse-Tone valve does not have a core. 5. For vibration dampening. Turn the swivel hex (#2) counterclockwise approximately 4½ turns to open the poppet (#3). Make sure all connections are tight. 4. mount the Inline Pulse-Tone as close as possible to the source of the shock. 5. The T handle on the charging and gauging assembly serves no purpose when either charging or checking precharge. 5. this nut must always be in the closed position. Do not leave the charging and gauging assembly permanently mounted to the top of the Inline Pulse-Tone in an attempt to monitor the precharge pressure. Remove the charging and gauging assembly from the Inline Pulse-Tone valve. Open the bleeder valve on charging and gauging assembly to vent the gas in the charging hose. Important Notice The charging valve used on the Inline Pulse-Tone is an MS28889-2 valve. 3.Catalog HY10-1630/US Inline Pulse-Tone™ Installation Tips 1. For shock dampening. 7. nitrogen cannot enter or leave the suppressor. The Inline Pulse-Tone is usually precharged to 50% of the system pressure. If the nut is not turned. Remove the valve cap (#1) from the Inline Pulse-Tone valve. 3. there is no need to utilize the ‘T’ handle on the gas chuck. All components must be rated for a pressure at least as high as the nitrogen source. however. Install the valve cap (#1). 7. Turn this nut counterclockwise to open the passage to the nitrogen chamber and clockwise to close the passage to the nitrogen. Connect the charging and gauging assembly to the Inline Pulse-Tone valve. 6. Hydraulic Accumulators Maintenance Instructions Checking the Precharge 1. #1 Valve Cap #2 Hex Nut #3 Poppet 184 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. After reading the nitrogen charge. Illinois USA . It is strongly recommended that the nitrogen bottle used have a high pressure regulator. Turn the swivel hex nut (#2) on the Inline Pulse-Tone valve clockwise approximately 4½ turns to close the valve poppet. 4. For pump pulsation suppression and pump noise reduction. gas bottle will have a lefthand thread. 8. Remove the charging and gauging assembly from the Inline Pulse-Tone. close the valve on the nitrogen bottle. Charging the Inline Pulse-Tone Use only inert gas such as nitrogen for pre-charging the Inline Pulse-Tone. Make sure nitrogen supply is shut off. 4. 3. Turn the swivel hex nut (#2) counterclockwise approximately 4½ turns open the poppet (#3). When you reach the required pressure level. 9. 8. If possible. It is opened and closed by the hex nut (#2). Attach hose to nitrogen bottle. Install the valve cap (#1). Open the valve on the nitrogen bottle slowly and allow the pressure to build to the desired level. When the poppet has seated. 2. use water pumped nitrogen (gas bottle will have a right-hand thread). 2. 2. The noise reduction will occur when the pump pressure exceeds the precharge pressure of the suppressor. It is only used when working with accumulators. During suppressor operation. Always close the hex nut #2 on the charging valve in order to seal the precharge in the Inline Pulse-Tone. apply approximately 50 to 70 inch/lbs of torque. Install the charging and gauging assembly onto the Inline Pulse-Tone valve. turn the swivel hex nut (#2) clockwise 4½ turns. 1. 6. mount the Inline Pulse-Tone directly at the outlet of the pump. You can now read the nitrogen charge on the pressure gauge. Remove the valve cap (#1) from the Inline Pulse-Tone valve. Either end of the Inline Pulse-Tone can serve as inlet or outlet. mount the Inline Pulse-Tone as close as possible to the pump outlet since the pump is usually the source of the vibrations. Torque to approximately 50 to 70 inch/lbs. The precharge pressure should be checked once every three months. Oil pumped nitrogen may be used. 7. 6. . lubricate the inside diameter of the ends of the bladder with Superlube grease provided. 3. 4. 3. 3. Lubricate the o-rings and the face of the end port that comes in contact with the bladder with Superlube grease provided or a PTFE base grease. Charging Valve #1 Valve Cap #2 Hex Nut #3 Poppet To Disassemble the Inline Pulse-Tone 1. 2. Push the diffuser tube out one end of the body. 9. Thread the charging valve part (#20) into the port on the steel body (#10). Lubricate the o-ring to hold it in position. Place the tube o-rings (#40) over the ends of the diffuser tube (#70). 4. O-Ring End Port O-Ring End Port Diffuser Bladder 70 30 40 50 60 185 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. remove the flanges of the bladder from their grooves and push the bladder out one end of the steel body. Remove valve cap (#1). 2. With a Spanner wrench or dowel pins. Turn the Inline Pulse-Tone 180° in the vise or fixture and remove the other end port. 5. tighten each end port approximately another 5°. Visually inspect and clean all parts prior to assembly. Place end port o-rings (#50) in the grooves of the end ports (#60). 2. Precharge will vent to atmosphere. With a screwdriver or other flat device. Thread the second end port into the open end of the steel body until you have metal to metal contact. remove one of the end ports. 5. 11. 6. Place the tube face o-ring (#30) on the proper end of the diffuser tube (#70) as shown in the sketch below. Make certain to vent the gas charge before attempting to disassemble the Inline Pulse-Tone. Do not lubricate the bladder at this time.D.Catalog HY10-1630/US Inline Pulse-Tone™ Maintenance Disassembly To vent precharge 1. Lubricate the outside diameter of the diffuser tube (#70) with hydraulic oil and insert it into the inside diameter of the bladder which is installed in the steel body. Hydraulic Accumulators Maintenance Instructions Assembly 1. Illinois USA Maint. Make certain that the face of the end port is properly lubricated. the flanges at the ends of the bladder must be properly seated in the grooves in the steel body. Turn swivel hex nut (#2) counterclockwise approximately 4½ turns to open poppet (#3). The charging valve has an o-ring at the base of the valve to seal between the valve port and the steel body. 10. Place one end port (#60) in a vise or fixture to hold it during assembly. 6. 8. There is usually no need to remove the charging valve. Leave the charging valve in open position. Lubricate the o-rings to hold them in position. With a spanner wrench or dowel pins. 60 50 20 40 10 80 10 20 30 40 50 60 70 80 Body Charging Valve Tube Face O-Ring Tube O. Insert the bladder (#80) into the steel body (#10). 7. Place the steel body (#10) over the end port and thread it onto the end port until you have metal to metal contact. Lightly oil the o-ring to hold it in position while installing the valve. Refer to above venting procedure. After installing the bladder and it is properly seated in the steel body. Place the Inline Pulse-Tone in a vise or fixture. If the retaining ring is damaged. 3) Replace the damaged washer with a new one.Catalog HY10-1630/US Gas Chucks 8708150000 The use of safety glasses during the disassembly of the gas chuck is recommended. 186 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. 2) Remove the exter nal hexagon shaped sleeve and the two internal round sleeves to reach the copper washer. Otherwise. replace the entire gas chuck. part number 5824390000. Illinois USA . Hydraulic Accumulators Maintenance Instructions 1) Insert the head of a flat screwdriver at one edge of the retaining ring opening and slowly begin to remove the retaining ring. Caution: The retaining ring will spring out of the groove once half of it has been moved out of the groove. Note: The washer should drop out of the groove by it self. use a small screwdriver to remove it if necessary. Caution: Make sure that the retaining ring is completely seated into the groove prior to reusing the gas chuck. 4) Reassemble the sleeves. Hold the ring with one finger to avoid loosing it. 5) Reassemble the retaining ring back into the groove using a small screwdriver. 5GAL 3KPSI OS -28 2"NPT BA 5GAL 3KPSI OS -1 2"NPT BA 5GAL 3KPSI OS -3 2"NPT BA 5GAL 3KPSI OS -4 2"NPT BA 5GAL 3KPSI OS -6 2"NPT BA 5GAL 3KPSI OS -8 2"NPT BA 5GAL 3KPSI OS -28 2"NPT BA 10GAL 3KPSI OS -1 2"NPT BA 10GAL 3KPSI OS -3 2"NPT BA 10GAL 3KPSI OS -4 2"NPT BA 10GAL 3KPSI OS -6 2"NPT BA 10GAL 3KPSI OS -8 2"NPT BA 10GAL 3KPSI OS -28 2"NPT BA 10CI 3KPSI OS -3 .75"NPT BA 10CI 3KPSI WS -6 .75"NPT BA 5GAL 3KPSI OS -6 1.25"NPT BA 10CI 3KPSI OS -1 .5GAL 3KPSI WS -3 2"NPT BA 2.75"NPT BA 1PT 3KPSI OS -3 .5GAL 3KPSI OS -3 2"NPT BA 2.25"NPT BA 1GAL 3KPSI WS -4 1.5GAL 3KPSI OS -1 2"NPT BA 2.75"NPT BA 1QT 3KPSI WS -28 .75"NPT BA 1PT 3KPSI WS -28 .75"NPT BA 1QT 3KPSI OS -4 .75"NPT 187 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.25"NPT BA 1GAL 3KPSI WS -8 1.75"NPT BA 10CI 3KPSI WS -3 .5GAL 200PSI -1 3" FLG UL SRGKN 5GAL 200PSI -1 3" FLG UL SRGKN 10GAL 200PSI -1 3" FLG UL BA 1PT 3KPSI OS -1 .25"NPT BA 1GAL 3KPSI WS -3 1.75"NPT BA 1QT 3KPSI WS -3 .75"NPT BA 1PT 3KPSI WS -1 .75"NPT BA 1PT 3KPSI WS -6 .5"SAE BA 1GAL 3KPSI OS -3 1.25"NPT BA 1GAL 3KPSI OS -4 1.75"NPT BA 1PT 3KPSI OS -8 .75"NPT BA 1PT 3KPSI WS -4 .5"SAE KLVNT 80GAL -6 1.25"NPT BA 1GAL 3KPSI OS -6 1.5"SAE KLVNT 20GAL -6 1"SAE KLVNT 60GAL -6 1.25"NPT BA 150CI 3KPSI OS -1 1"NPT BA 150CI 3KPSI OS -3 1"NPT BA 150CI 3KPSI OS -4 1"NPT BA 150CI 3KPSI OS -6 1"NPT BA 150CI 3KPSI OS -28 1"NPT BA 150CI 3KPSI OS -8 1"NPT KLVNT 20GAL -8 1"SAE KLVNT 20GAL -28 1"SAE KLVNT 60GAL -8 1.75"NPT BA 5GAL 3KPSI WS -1 2"NPT BA 5GAL 3KPSI WS -3 2"NPT BA 5GAL 3KPSI WS -4 2"NPT BA 5GAL 3KPSI WS -6 2"NPT BA 5GAL 3KPSI WS -8 2"NPT BA 5GAL 3KPSI WS -28 2"NPT BA 10GAL 3KPSI WS -1 2"NPT BA 10GAL 3KPSI WS -3 2"NPT Model Number BA10B3U04W1 BA10B3U06W1 BA10B3U08W1 BA10B3U28W1 KV20M0T01A1 KV40M0T01A1 KV60M0T01A1 KV80M0T01A1 BA01B3U01W1 BA01B3U03W1 BA01B3U04W1 BA01B3U06W1 BA01B3U08W1 BA01B3U28W1 BA005B3U01A1 BA005B3U03A1 BA005B3U04A1 BA005B3U06A1 BA005B3U28A1 BA005B3U08A1 KV20M0T08A1 KV20M0T28A1 KV60M0T08A1 SK02S3FB01A1 SK05S3FB01A1 SK10S3FB01A1 SK02W2FA01U1 SK05W2FA01U1 SK10W2FA01U1 BA001B3U01A1 BA001B3U03A1 BA001B3U04A1 BA001B3U06A1 BA001B3U08A1 BA001B3U28A1 BA001B3U01W1 BA001B3U03W1 BA001B3U04W1 BA001B3U06W1 BA001B3U08W1 BA001B3U28W1 BA02B3U01W1 BA02B3U03W1 BA02B3U04W1 BA02B3U06W1 BA02B3U08W1 BA02B3U28W1 BA05B3H01W1 BA05B3H03W1 BA05B3H04W1 BA05B3H06W1 BA05B3H08W1 BA05B3H28W1 SK120W2FB01U1 KV40M0T06A1 KV20M0T06A1 KV60M0T06A1 KV80M0T06A1 BA01B3U03A1 BA01B3U04A1 BA01B3U06A1 BA01B3U08A1 BA01B3U28A1 BAC10B3U01W1 BAC10B3UO3W1 BAC10B3UO4W1 BAC10B3UO6W1 Description BA 10GAL 3KPSI WS -4 2"NPT BA 10GAL 3KPSI WS -6 2"NPT BA 10GAL 3KPSI WS -8 2"NPT BA 10GAL 3KPSI WS -28 2"NPT KLVNT 20GAL -1 1"SAE KLVNT 40GAL -1 1.5GAL 3KPSI WS -4 2"NPT BA 2.75"NPT BA 1QT 3KPSI OS -28 .5"SAE BA 1GAL 3KPSI WS -1 1.5GAL 3KPSI WS -6 2"NPT BA 2.5"SAE BA 1QT 3KPSI OS -1 .5"SAE KLVNT 80GAL -1 1.5GAL 275PSI WS -1 3" FLG SRGKN 2.5GAL 3KPSI WS -1 2"NPT BA 2.75"NPT BA 1PT 3KPSI OS -4 .75"NPT BA 1QT 3KPSI WS -4 .75"NPT BA 1QT 3KPSI WS -6 .5GAL 3KPSI WS -8 2"NPT BA 2.75"NPT BA 1PT 3KPSI OS -28 .75"NPT BA 10CI 3KPSI WS -4 .5GAL 3KPSI OS -6 2"NPT BA 2.5"SAE SRGKN 2.25"NPT BA 10CI 3KPSI WS -1 .75"NPT BA 1QT 3KPSI OS -3 .5GAL 275PSI WS -8 3" FLG SRGKN 2.25"NPT BA 1GAL 3KPSI OS -8 1.5GAL 3KPSI OS -4 2"NPT BA 2.5"SAE KLVNT 60GAL -1 1.5GAL 275PSI WS -28 3" FLG SRGKN 5GAL 275PSI WS -1 3" FLG SRGKN 5GAL 275PSI WS -8 3" FLG SRGKN 5GAL 275PSI WS -28 3" FLG SRGKN 10GAL 275PSI WS -1 3" FLG SRGKN 10GAL 275PSI WS -8 3" FLG SRGKN 10GAL 275PSI WS -28 3" FLG BA 2.25"NPT BA 1GAL 3KPSI WS -28 1.75"NPT BA 10CI 3KPSI OS -6 .75"NPT BA 1QT 3KPSI WS -1 .5GAL 3KPSI OS -8 2"NPT BA 2.75"NPT BA 1PT 3KPSI WS -8 .75"NPT BA 1QT 3KPSI WS -8 .75"NPT BA 2.5GAL 275PSI WS -1 SLURRY 4" FLG SRGKN 5GAL 275PSI WS -1 SLURRY 4" FLG SRGKN 10GAL 275PSI WS -1 SLURRY 4" FLG SRGKN 2.75"NPT BA 10CI 3KPSI OS -4 .75"NPT BA 5GAL 3KPSI OS HF -1 4"NPT BA 5GAL 3KPSI OS HF -3 4"NPT BA 5GAL 3KPSI OS HF -4 4"NPT BA 5GAL 3KPSI OS HF -6 4"NPT BA 5GAL 3KPSI OS HF -8 4"NPT BA 5GAL 3KPSI OS HF -28 4"NPT BA 10GAL 3KPSI OS HF -1 4"NPT BA 10GAL 3KPSI OS HF -3 4"NPT BA 10GAL 3KPSI OS HF -4 4"NPT BA 10GAL 3KPSI OS HF -6 4"NPT BA 10GAL 3KPSI OS HF -8 4"NPT BA 10GAL 3KPSI OS HF -28 4"NPT SRGKN 2.Catalog HY10-1630/US EPN to Model Number Crossover EPN 800001 800010 800019 800381 800575 800577 800578 800580 800581 800584 800592 800593 800595 800597 800598 800650 800652 800653 800655 800657 800661 800665 800667 800668 800670 800672 800676 800680 800685 800689 800695 800700 800703 800710 800715 800718 800730 800732 800733 800734 800735 800738 800761 800763 800764 800766 800767 800770 800776 800778 800779 800781 800782 800785 800793 800794 800796 800798 800802 800820 800822 800823 800824 800825 800828 800834 800836 Greer Accumulators Model Number Conversion Table EPN 800837 800838 800839 800842 800876 800877 800878 800879 800885 800887 800888 800889 800890 800893 800970 800972 800973 800974 800978 800979 805017 805018 805043 805150 805160 805170 810000 810015 810030 810070 810072 810073 810074 810075 810078 810393 810395 810396 810397 810398 810401 810869 810871 810872 810873 810874 810877 810880 810882 810883 810884 810885 810888 812760 812976 813026 813053 813075 813132 813133 813134 813135 813138 813220 813222 813223 813224 Model Number BA01B3U01A1 BAC10B3U01A1 BA002B3U01W1 BA05B3T06A1 BA002B3U01A1 BA002B3U03A1 BA002B3U04A1 BA002B3U06A1 BA002B3U08A1 BA002B3U28A1 BA002B3U03W1 BA002B3U04W1 BA002B3U06W1 BA002B3U08W1 BA002B3U28W1 BA05B3H01A1 BA05B3H03A1 BA05B3H04A1 BA05B3H06A1 BA05B3H08A1 BA05B3H28A1 BA10B3H01A1 BA10B3H03A1 BA10B3H04A1 BA10B3H06A1 BA10B3H08A1 BA10B3H28A1 SK02W3FA01A1 SK02W3FA08A1 SK02W3FA28A1 SK05W3FA01A1 SK05W3FA08A1 SK05W3FA28A1 SK10W3FA01A1 SK10W3FA08A1 SK10W3FA28A1 BA02B3U01A1 BA02B3U03A1 BA02B3U04A1 BA02B3U06A1 BA02B3U08A1 BA02B3U28A1 BA05B3U01A1 BA05B3U03A1 BA05B3U04A1 BA05B3U06A1 BA05B3U08A1 BA05B3U28A1 BA10B3U01A1 BA10B3U03A1 BA10B3U04A1 BA10B3U06A1 BA10B3U08A1 BA10B3U28A1 BAC10B3UO3A1 BAC10B3UO4A1 BAC10B3UO6A1 BAC10B3UO8A1 BAC10B3U28A1 BA05B3U01W1 BA05B3U03W1 BA05B3U04W1 BA05B3U06W1 BA05B3U08W1 BA05B3U28W1 BA10B3U01W1 BA10B3U03W1 Description BA 1GAL 3KPSI OS -1 1.75"NPT BA 10CI 3KPSI OS -28 .5GAL 3KPSI WS -28 2"NPT BA 5GAL 3KPSI WS HF -1 4"NPT BA 5GAL 3KPSI WS HF -3 4"NPT BA 5GAL 3KPSI WS HF -4 4"NPT BA 5GAL 3KPSI WS HF -6 4"NPT BA 5GAL 3KPSI WS HF -8 4"NPT BA 5GAL 3KPSI WS HF -28 4"NPT SRGKN 120GAL 200PSI -1 4" FLG UL KLVNT 40GAL -6 1.75"NPT BA 10CI 3KPSI OS -8 .75"NPT BA 1QT 3KPSI OS -8 .75"NPT BA 1QT 3KPSI OS -6 .75"NPT BA 1PT 3KPSI WS -3 . Illinois USA .25"NPT BA 1GAL 3KPSI WS -6 1.25"NPT BA 1GAL 3KPSI OS -28 1.75"NPT BA 1PT 3KPSI OS -6 . 25" NPT BA 1GAL 5KPSI WS -8 1.25"SAE BA 1GAL 3KPSI OS -28 1.5GAL 3KPSI OS TOPRPR -3 2"NPT BA 2.25"SAE BA 1GAL 3KPSI OS -6 1.5GAL 3KPSI OS HF -1 4"NPT BA 2.25" NPT BA 1GAL 5KPSI OS -8 1.5GAL 3KPSI WS TOPRPR -4 2"NPT BA 2.5GAL 3KPSI WS HF -4 4"NPT BA 2.5GAL 3KPSI WS HF -1 4"NPT BA 2.25" NPT BA 1GAL 5KPSI WS -3 1.5GAL 3KPSI OS HF -8 4"NPT BA 2.5GAL 3KPSI WS TOPRPR -8 2"NPT BA 2.25"SAE BA 1GAL 5KPSI OS -1 1.75"NPT BA 150CI 3KPSI WS -1 1"NPT BA 150CI 3KPSI WS -3 1"NPT BA 150CI 3KPSI WS -4 1"NPT BA 150CI 3KPSI WS -6 1"NPT BA 150CI 3KPSI WS -8 1"NPT BA 150CI 3KPSI WS -28 1"NPT BA 2.5GAL 3KPSI WS TOPRPR -6 2"NPT BA 5GAL 3KPSI WS TOPRPR -1 2"NPT BA 5GAL 3KPSI WS TOPRPR -3 2"NPT BA 5GAL 3KPSI WS TOPRPR -4 2"NPT BA 5GAL 3KPSI WS TOPRPR -8 2"NPT BA 5GAL 3KPSI WS TOPRPR -28 2"NPT BA 5GAL 3KPSI WS TOPRPR -6 2"NPT BA 10GAL 3KPSI WS TOPRPR -1 2"NPT BA 10GAL 3KPSI WS TOPRPR -3 2"NPT BA 10GAL 3KPSI WS TOPRPR -4 2"NPT BA 10GAL 3KPSI WS TOPRPR -8 2"NPT BA 10GAL 3KPSI WS TOPRPR -28 2"NPT BA 10GAL 3KPSI WS TOPRPR -6 2"NPT BA 15GAL 3KPSI WS TOPRPR -1 2"NPT BA 15GAL 3KPSI WS TOPRPR -3 2"NPT BA 15GAL 3KPSI WS TOPRPR -4 2"NPT 188 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.25"SAE BA 1GAL 3KPSI OS -8 1. Illinois USA .5GAL 3KPSI OS TOPRPR -28 2"NPT BA 2.25" NPT BA 1GAL 5KPSI WS -28 1.5GAL 3KPSI OS TOPRPR -1 2"NPT BA 2.25"SAE BA 1GAL 3KPSI OS -4 1.5GAL 3KPSI OS HF -4 4"NPT BA 2.5GAL 3KPSI WS HF -6 4"NPT BA 2.5GAL 3KPSI WS TOPRPR -3 2"NPT BA 2.25" NPT BA 1GAL 5KPSI OS -3 1.5GAL 3KPSI OS HF -6 4"NPT BA 2.5GAL 3KPSI OS TOPRPR -8 2"NPT BA 2.5GAL 3KPSI WS TOPRPR -1 2"NPT BA 2.25" NPT BA 15GAL 3KPSI OS HF -1 4"NPT BA 15GAL 3KPSI OS HF -3 4"NPT BA 15GAL 3KPSI OS HF -4 4"NPT BA 15GAL 3KPSI OS HF -6 4"NPT BA 15GAL 3KPSI OS HF -8 4"NPT BA 15GAL 3KPSI OS HF -28 4"NPT BA 11GAL 3KPSI OS TOPRPR -1 2"NPT BA 11GAL 3KPSI OS TOPRPR -3 2"NPT BA 11GAL 3KPSI OS TOPRPR -4 2"NPT BA 11GAL 3KPSI OS TOPRPR -6 2"NPT BA 11GAL 3KPSI OS TOPRPR -8 2"NPT BA 11GAL 3KPSI OS TOPRPR -28 2"NPT BA 2.5"SAE BA 2.25" NPT BA 1GAL 5KPSI OS -28 1.25"SAE BA 1GAL 3KPSI OS -3 1.5GAL 3KPSI WS HF -3 4"NPT BA 2.5"SAE BA 25GAL 3KPSI OS TOPRPR -1 3"NPT BA 40GAL 3KPSI OS TOPRPR -1 3"NPT BA 40GAL 3KPSI WS TOPRPR -1 3"NPT BA 15GAL 3KPSI OS -1 2"NPT BA 15GAL 3KPSI WS -1 2"NPT BA 25GAL 3KPSI OS TOPRPR -3 3"NPT BA 25GAL 3KPSI OS TOPRPR -4 3"NPT BA 25GAL 3KPSI OS TOPRPR -6 3"NPT BA 25GAL 3KPSI OS TOPRPR -8 3"NPT BA 25GAL 3KPSI OS TOPRPR -28 3"NPT BA 25GAL 3KPSI WS TOPRPR -1 3"NPT BA 15GAL 3KPSI OS -28 2"NPT BA 15GAL 3KPSI OS -6 2"NPT BA 15GAL 3KPSI OS -8 2"NPT BA 15GAL 3KPSI OS -4 2"NPT BA 15GAL 3KPSI OS -3 2"NPT BA 40GAL 3KPSI OS TOPRPR -28 3"NPT BA 40GAL 3KPSI OS TOPRPR -8 3"NPT BA 40GAL 3KPSI OS TOPRPR -3 3"NPT BA 40GAL 3KPSI OS TOPRPR -4 3"NPT BA 40GAL 3KPSI OS TOPRPR -6 3"NPT BA 15GAL 3KPSI WS -3 2"NPT BA 15GAL 3KPSI WS -4 2"NPT BA 15GAL 3KPSI WS -8 2"NPT BA 15GAL 3KPSI WS -28 2"NPT BA 15GAL 3KPSI WS -6 2"NPT BA 1GAL 3KPSI OS -1 1.5GAL 3KPSI WS TOPRPR -28 2"NPT BA 2.5GAL 3KPSI OS TOPRPR -4 2"NPT BA 2.25" NPT Model Number BA01B5U04A1 BA01B5U06A1 BA01B5U08A1 BA01B5U28A1 BA01B5U01W1 BA01B5U03W1 BA01B5U04W1 BA01B5U08W1 BA01B5U28W1 BA01B5U06W1 BA15B3H01A1 BA15B3H03A1 BA15B3H04A1 BA15B3H06A1 BA15B3H08A1 BA15B3H28A1 BA11T3U01A1 BA11T3U03A1 BA11T3U04A1 BA11T3U06A1 BA11T3U08A1 BA11T3U28A1 BA02T3U01A1 BA02T3U03A1 BA02T3U04A1 BA02T3U08A1 BA02T3U28A1 BA02T3U06A1 BA05T3U01A1 BA05T3U03A1 BA05T3U04A1 BA05T3U08A1 BA05T3U28A1 BA05T3U06A1 BA10T3U01A1 BA10T3U03A1 BA10T3U04A1 BA10T3U08A1 BA10T3U28A1 BA10T3U06A1 BA15T3U01A1 BA15T3U03A1 BA15T3U04A1 BA15T3U08A1 BA15T3U28A1 BA15T3U06A1 BA02T3U01W1 BA02T3U03W1 BA02T3U04W1 BA02T3U08W1 BA02T3U28W1 BA02T3U06W1 BA05T3U01W1 BA05T3U03W1 BA05T3U04W1 BA05T3U08W1 BA05T3U28W1 BA05T3U06W1 BA10T3U01W1 BA10T3U03W1 BA10T3U04W1 BA10T3U08W1 BA10T3U28W1 BA10T3U06W1 BA15T3U01W1 BA15T3U03W1 BA15T3U04W1 Description BA 1GAL 5KPSI OS -4 1.5GAL 3KPSI OS TOPRPR -6 2"NPT BA 5GAL 3KPSI OS TOPRPR -1 2"NPT BA 5GAL 3KPSI OS TOPRPR -3 2"NPT BA 5GAL 3KPSI OS TOPRPR -4 2"NPT BA 5GAL 3KPSI OS TOPRPR -8 2"NPT BA 5GAL 3KPSI OS TOPRPR -28 2"NPT BA 5GAL 3KPSI OS TOPRPR -6 2"NPT BA 10GAL 3KPSI OS TOPRPR -1 2"NPT BA 10GAL 3KPSI OS TOPRPR -3 2"NPT BA 10GAL 3KPSI OS TOPRPR -4 2"NPT BA 10GAL 3KPSI OS TOPRPR -8 2"NPT BA 10GAL 3KPSI OS TOPRPR -28 2"NPT BA 10GAL 3KPSI OS TOPRPR -6 2"NPT BA 15GAL 3KPSI OS TOPRPR -1 2"NPT BA 15GAL 3KPSI OS TOPRPR -3 2"NPT BA 15GAL 3KPSI OS TOPRPR -4 2"NPT BA 15GAL 3KPSI OS TOPRPR -8 2"NPT BA 15GAL 3KPSI OS TOPRPR -28 2"NPT BA 15GAL 3KPSI OS TOPRPR -6 2"NPT BA 2.25" NPT BA 1GAL 5KPSI OS -6 1.75"NPT BA 10CI 3KPSI WS -28 .Catalog HY10-1630/US EPN to Model Number Crossover EPN 813225 813228 813290 813292 813293 813294 813295 813298 813310 813312 813313 813314 813315 813318 813460 813500 813540 813560 813603 813620 813622 813623 813624 813625 813628 813650 813652 813653 813654 813655 813658 813803 813804 835160 835161 835164 835165 835166 839160 839161 839162 839163 839165 839170 839180 839181 839182 839184 839185 839270 839271 839272 839273 839275 841711 841712 841713 841714 841715 841720 841722 841723 841724 841725 841726 842320 842321 Greer Accumulators Model Number Conversion Table EPN 842322 842323 842324 842325 842330 842331 842332 842334 842335 842336 842530 842531 842532 842533 842534 842536 845311 845313 845314 845315 845318 845319 845370 845372 845373 845374 845375 845376 845380 845382 845383 845384 845385 845386 845390 845392 845393 845394 845395 845396 845400 845402 845403 845404 845405 845406 845410 845412 845413 845414 845415 845416 845420 845422 845423 845424 845425 845426 845430 845432 845433 845434 845435 845436 845440 845442 845443 Model Number BAC10B3UO8W1 BAC10B3U28W1 BA005B3U01W1 BA005B3U03W1 BA005B3U04W1 BA005B3U06W1 BA005B3U08W1 BA005B3U28W1 BA02B3H01W1 BA02B3H03W1 BA02B3H04W1 BA02B3H06W1 BA02B3H08W1 BA02B3H28W1 SK25W2FB01U1 SK40W2FB01U1 SK80W2FB01U1 SK100W2FB01U1 KV80M0T08A1 BA02B3H01A1 BA02B3H03A1 BA02B3H04A1 BA02B3H06A1 BA02B3H08A1 BA02B3H28A1 BA10B3H01W1 BA10B3H03W1 BA10B3H04W1 BA10B3H06W1 BA10B3H08W1 BA10B3H28W1 KV40M0T08A1 KV40M0T281A1 BA25T3U01A1 BA40T3U01A1 BA40T3U01W1 BA15B3U01A1 BA15B3U01W1 BA25T3U03A1 BA25T3U04A1 BA25T3U06A1 BA25T3U08A1 BA25T3U28A1 BA25T3U01W1 BA15B3U28A1 BA15B3U06A1 BA15B3U08A1 BA15B3U04A1 BA15B3U03A1 BA40T3U28A1 BA40T3U08A1 BA40T3U03A1 BA40T3U04A1 BA40T3U06A1 BA15B3U03W1 BA15B3U04W1 BA15B3U08W1 BA15B3U28W1 BA15B3U06W1 BA01B3T01A1 BA01B3T03A1 BA01B3T28A1 BA01B3T06A1 BA01B3T08A1 BA01B3T04A1 BA01B5U01A1 BA01B5U03A1 Description BA 10CI 3KPSI WS -8 .25" NPT BA 1GAL 5KPSI WS -1 1.5GAL 3KPSI WS HF -28 4"NPT SRGKN 25GAL 200PSI -1 4" FLG UL SRGKN 40GAL 200PSI -1 4" FLG UL SRGKN 80GAL 200PSI -1 4" FLG UL SRGKN 100GAL 200PSI -1 4" FLG UL KLVNT 80GAL -8 1.5GAL 3KPSI WS HF -8 4"NPT BA 2.5"SAE KLVNT 40GAL -28 1.25" NPT BA 1GAL 5KPSI WS -4 1.25" NPT BA 1GAL 5KPSI WS -6 1.5GAL 3KPSI OS HF -28 4"NPT BA 10GAL 3KPSI WS HF -1 4"NPT BA 10GAL 3KPSI WS HF -3 4"NPT BA 10GAL 3KPSI WS HF -4 4"NPT BA 10GAL 3KPSI WS HF -6 4"NPT BA 10GAL 3KPSI WS HF -8 4"NPT BA 10GAL 3KPSI WS HF -28 4"NPT KLVNT 40GAL -8 1.5GAL 3KPSI OS HF -3 4"NPT BA 2. 25"SAE BA 1GAL 3KPSI OS -1 4BLT BA 5GAL 3KPSI OS -1 4BLT BA 2.5GAL 3KPSI OS -6 1.5"SAE BA 5GAL 3KPSI OS -1 1.25" SAE BA 1GAL 3KPSI WS -1 1.5"SAE BA 15GAL 3KPSI OS -6 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -6 1.5"SAE BA 5GAL 3KPSI WS -4 1.5"SAE BA 10CI 3KPSI OS -6 .5"SAE BA 5GAL 3KPSI OS -28 1.5GAL 3KPSI OS TOPRPR -1 1.5"SAE BA 10GAL 3KPSI OS -8 1.5GAL 3KPSI OS TOPRPR -8 1.75"SAE BA 1QT 3KPSI OS -3 .5"SAE BA 15GAL 3KPSI OS -1 1.5GAL 3KPSI OS TOPRPR -3 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -3 1.5"SAE BA 1PT 3KPSI OS -1 .5"SAE BA 2.5"SAE BA 5GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 15GAL 3KPSI OS -8 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -28 1.5"SAE BA 10GAL 3KPSI OS TOPRPR -6 1.5"SAE BA 15GAL 3KPSI OS -3 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -28 1.25"SAE BA 1GAL 3KPSI WS -4 1.5"SAE BA 10GAL 3KPSI OS -28 1.5"SAE BA 5GAL 3KPSI WS -1 1.5"SAE BA 11GAL 3KPSI OS HF -1 4"NPT BA 11GAL 3KPSI OS HF -3 4"NPT BA 11GAL 3KPSI OS HF -4 4"NPT BA 11GAL 3KPSI OS HF -6 4"NPT BA 11GAL 3KPSI OS HF -8 4"NPT BA 11GAL 3KPSI OS HF -28 4"NPT BA 11GAL 3KPSI WS HF -1 4"NPT Model Number BA11B3H03W1 BA11B3H04W1 BA11B3H06W1 BA11B3H08W1 BA11B3H28W1 BA01B5T01A1 BA01B5T04A1 BA01B3T01W1 BA01B3T04W1 BA01B3T28W1 BA01B3F01A1 BA06B3F01A1 BA02T3T01A1 BA02T3T03A1 BA02T3T04A1 BA02T3T06A1 BA02T3T08A1 BA02T3T28A1 BA05T3T01A1 BA05T3T03A1 BA05T3T04A1 BA05T3T06A1 BA05T3T08A1 BA05T3T28A1 BAC10B3T01A1 BAC10B3TO3A1 BAC10B3TO4A1 BAC10B3TO6A1 BAC10B3TO8A1 BAC10B3T28A1 BA001B3T01A1 BA001B3T03A1 BA001B3T04A1 BA001B3T06A1 BA001B3T08A1 BA001B3T28A1 BA002B3T01A1 BA002B3T03A1 BA002B3T04A1 BA002B3T06A1 BA002B3T08A1 BA002B3T28A1 BA005B3T01A1 BA10T3T01A1 BA10T3T03A1 BA10T3T04A1 BA10T3T06A1 BA10T3T08A1 BA10T3T28A1 BA11T3T01A1 BA11T3T03A1 BA11T3T04A1 BA11T3T06A1 BA11T3T08A1 BA11T3T28A1 BA15T3T01A1 BA15T3T03A1 BA15T3T04A1 BA15T3T06A1 BA15T3T08A1 BA15T3T28A1 BA02T3F01A1 BA02T3F04A1 BA02T3F28A1 BA05T3F01A1 BA05T3F04A1 BA15B3T01W1 Description BA 11GAL 3KPSI WS HF -3 4"NPT BA 11GAL 3KPSI WS HF -4 4"NPT BA 11GAL 3KPSI WS HF -6 4"NPT BA 11GAL 3KPSI WS HF -8 4"NPT BA 11GAL 3KPSI WS HF -28 4"NPT BA 1GAL 5KPSI OS -1 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -1 1.5"SAE BA 2.75"SAE BA 150CI 3KPSI OS -1 1"SAE BA 10GAL 3KPSI OS TOPRPR -1 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -6 1.5"SAE BA 2.5"SAE BA 2.5GAL 3KPSI OS TOPRPR -4 4BLT BA 2. Illinois USA .5"SAE BA 15GAL 3KPSI OS TOPRPR -3 1.5"SAE BA 10GAL 3KPSI OS -1 1.75"SAE BA 1QT 3KPSI OS -28 .75"SAE BA 1PT 3KPSI OS -6 .5GAL 3KPSI OS TOPRPR -28 4BLT BA 5GAL 3KPSI OS TOPRPR -1 4BLT BA 5GAL 3KPSI OS TOPRPR -4 4BLT BA 15GAL 3KPSI WS -1 1.5"SAE BA 11GAL 3KPSI OS -1 1.5"SAE BA 10CI 3KPSI OS -1 .5GAL 3KPSI OS -4 1.5GAL 3KPSI OS -3 1.Catalog HY10-1630/US EPN to Model Number Crossover EPN 845444 845445 845446 846890 846892 846893 846894 846895 846896 846940 846942 846943 846944 846945 846948 847550 847552 847553 847554 847555 847556 848900 848901 848902 848903 848904 848906 849381 849382 849390 849391 849392 849394 849396 849592 849593 849594 849596 849760 849761 849762 849763 849764 849768 849900 849901 849910 849911 849912 849913 849914 849916 850630 850633 850670 850671 850672 850673 850674 850676 850810 850811 850812 850813 850814 850816 850820 Greer Accumulators Model Number Conversion Table EPN 850821 850822 850823 850824 850826 851130 851133 851230 851233 851236 851330 851335 851420 851421 851422 851423 851424 851426 851430 851431 851432 851433 851434 851436 851520 851521 851522 851523 851524 851526 851540 851541 851542 851543 851544 851546 851550 851551 851552 851553 851554 851556 851560 851590 851591 851592 851593 851594 851596 851780 851781 851782 851783 851784 851786 852480 852481 852482 852483 852484 852486 853710 853712 853715 853720 853723 854530 Model Number BA15T3U08W1 BA15T3U28W1 BA15T3U06W1 BA11B3U01W1 BA11B3U03W1 BA11B3U04W1 BA11B3U08W1 BA11B3U28W1 BA11B3U06W1 BA11B3U01A1 BA11B3U03A1 BA11B3U04A1 BA11B3U08A1 BA11B3U28A1 BA11B3U06A1 BA11T3U01W1 BA11T3U03W1 BA11T3U04W1 BA11T3U08W1 BA11T3U28W1 BA11T3U06W1 BA15B3H01W1 BA15B3H03W1 BA15B3H04W1 BA15B3H06W1 BA15B3H08W1 BA15B3H28W1 SK10W3FA04A1 SK05W3FA04A1 BA05B3T04A1 BA05B3T03A1 BA05B3T01A1 BA05B3T08A1 BA05B3T28A1 BA11B3T04A1 BA11B3T06A1 BA11B3T08A1 BA11B3T28A1 BA02B3T01A1 BA02B3T03A1 BA02B3T04A1 BA02B3T06A1 BA02B3T08A1 BA02B3T28A1 BA11B3T01A1 BA11B3T03A1 BA15B3T01A1 BA15B3T03A1 BA15B3T04A1 BA15B3T06A1 BA15B3T08A1 BA15B3T28A1 BA05B3T01W1 BA05B3T04W1 BA10B3T01A1 BA10B3T03A1 BA10B3T04A1 BA10B3T06A1 BA10B3T08A1 BA10B3T28A1 BA11B3HT01A1 BA11B3H03A1 BA11B3H04A1 BA11B3H06A1 BA11B3H08A1 BA11B3H28A1 BA11B3H01W1 Description BA 15GAL 3KPSI WS TOPRPR -8 2"NPT BA 15GAL 3KPSI WS TOPRPR -28 2"NPT BA 15GAL 3KPSI WS TOPRPR -6 2"NPT BA 11GAL 3KPSI WS -1 2"NPT BA 11GAL 3KPSI WS -3 2"NPT BA 11GAL 3KPSI WS -4 2"NPT BA 11GAL 3KPSI WS -8 2"NPT BA 11GAL 3KPSI WS -28 2"NPT BA 11GAL 3KPSI WS -6 2"NPT BA 11GAL 3KPSI OS -1 2"NPT BA 11GAL 3KPSI OS -3 2"NPT BA 11GAL 3KPSI OS -4 2"NPT BA 11GAL 3KPSI OS -8 2"NPT BA 11GAL 3KPSI OS -28 2"NPT BA 11GAL 3KPSI OS -6 2"NPT BA 11GAL 3KPSI WS TOPRPR -1 2"NPT BA 11GAL 3KPSI WS TOPRPR -3 2"NPT BA 11GAL 3KPSI WS TOPRPR -4 2"NPT BA 11GAL 3KPSI WS TOPRPR -8 2"NPT BA 11GAL 3KPSI WS TOPRPR -28 2"NPT BA 11GAL 3KPSI WS TOPRPR -6 2"NPT BA 15GAL 3KPSI WS HF -1 4"NPT BA 15GAL 3KPSI WS HF -3 4"NPT BA 15GAL 3KPSI WS HF -4 4"NPT BA 15GAL 3KPSI WS HF -6 4"NPT BA 15GAL 3KPSI WS HF -8 4"NPT BA 15GAL 3KPSI WS HF -28 4"NPT SRGKN 10GAL 275PSI WS -4 3" FLG SRGKN 5GAL 275PSI WS -4 3" FLG BA 5GAL 3KPSI OS -4 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -28 1.76"SAE BA 1PT 3KPSI OS -8 .5"SAE BA 10CI 3KPSI OS -3 .5GAL 3KPSI OS TOPRPR -28 1.75"SAE BA 10CI 3KPSI OS -28 .5"SAE BA 5GAL 3KPSI OS TOPRPR -8 1.5"SAE BA 2.5"SAE BA 10GAL 3KPSI OS TOPRPR -8 1.75"SAE BA 1QT 3KPSI OS -6 .5"SAE BA 2.5"SAE 189 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5"SAE BA 5GAL 3KPSI OS -8 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -4 1.25"SAE BA 1GAL 3KPSI WS -28 1.5"SAE BA 11GAL 3KPSI OS -8 1.5"SAE BA 15GAL 3KPSI OS -4 1.5"SAE BA 11GAL 3KPSI OS -3 1.5"SAE BA 2.5"SAE BA 10GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 2.5"SAE BA 11GAL 3KPSI OS -6 1.5"SAE BA 10GAL 3KPSI OS -3 1.5"SAE BA 15GAL 3KPSI OS -28 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -8 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 10GAL 3KPSI OS -6 1.5"SAE BA 10CI 3KPSI OS -4 .5"SAE BA 11GAL 3KPSI OS -4 1.75"SAE BA 1QT 3KPSI OS -8 .5"SAE BA 2.5GAL 3KPSI OS -1 1.5GAL 3KPSI OS -28 1.5"SAE BA 2.5"SAE BA 11GAL 3KPSI OS -28 1.5"SAE BA 2.5GAL 3KPSI OS -8 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -1 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -3 1.5"SAE BA 10GAL 3KPSI OS TOPRPR -28 1.5"SAE BA 2.75"SAE BA 1QT 3KPSI OS -4 .75"SAE BA 1PT 3KPSI OS -3 .5"SAE BA 11GAL 3KPSI OS TOPRPR -1 1.25" SAE BA 1GAL 5KPSI OS -4 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -6 1.5GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 10GAL 3KPSI OS -4 1.75"SAE BA 1PT 3KPSI OS -4 .75"SAE BA 1QT 3KPSI OS -1 .5"SAE BA 10GAL 3KPSI OS TOPRPR -3 1.5"SAE BA 10CI 3KPSI OS -8 .5"SAE BA 11GAL 3KPSI OS TOPRPR -8 1.5GAL 3KPSI OS TOPRPR -6 1.75"SAE BA 1PT 3KPSI OS -28 .5GAL 3KPSI OS TOPRPR -1 4BLT BA 2.5"SAE BA 5GAL 3KPSI OS -3 1. 5" SAE BA 5GAL 5KPSI WS TOPRPR -6 1.5"SAE BA 1GAL 5KPSI WS -1 1.5"SAE BA 10GAL 3KPSI OS -1 4BLT BA 10GAL 3KPSI OS -4 4BLT BA 10GAL 3KPSI OS -28 4BLT BA 10CI 3KPSI WS -1 .5GAL 5KPSI OS TOPRPR -3 2" NPT BA 2.5GAL 5KPSI WS TOPRPR -1 2" NPT BA 2.5" SAE BA 2.5"SAE (FIBERGLAS) BA 10GAL 3KPSI OS TOPRPR -1 2" 4BLT BA 10GAL 3KPSI OS TOPRPR -8 2" 4BLT BA 15GAL 3KPSI OS TOPRPR -1 2" 4BLT BA 2.5"SAE BA 5GAL 3KPSI WS TOPRPR -4 1.5GAL 5KPSI WS TOPRPR -28 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -1 2" NPT BA 5GAL 5KPSI OS TOPRPR -3 2" NPT BA 5GAL 5KPSI OS TOPRPR -4 2" NPT BA 5GAL 5KPSI OS TOPRPR -6 2" NPT BA 5GAL 5KPSI OS TOPRPR -8 2" NPT BA 5GAL 5KPSI OS TOPRPR -28 2" NPT BA 5GAL 5KPSI WS TOPRPR -1 2" NPT BA 5GAL 5KPSI WS TOPRPR -3 2" NPT BA 5GAL 5KPSI WS TOPRPR -4 2" NPT BA 5GAL 5KPSI WS TOPRPR -6 2" NPT BA 5GAL 5KPSI WS TOPRPR -8 2" NPT BA 5GAL 5KPSI WS TOPRPR -28 2" NPT BA 5GAL 5KPSI OS TOPRPR -1 1.5"SAE (FIBERGLAS) KLVNT 20GAL -8 1.5"SAE BA 11GAL 3KPSI WS -1 1.5GAL 5KPSI OS TOPRPR -3 1.5GAL 5KPSI WS TOPRPR -4 1.5GAL -1 1"SAE (FIBERGLAS) KLVNT 2.5GAL 5KPSI WS TOPRPR -1 1.5"SAE BA 10GAL 3KPSI WS -4 1.5"SAE BA 1PT 3KPSI WS -1 .5GAL 5KPSI WS TOPRPR -1 2" 4 BOLT BA 2.5GAL 5KPSI OS TOPRPR -6 2" NPT BA 2.5GAL 3KPSI WS -8 1.5GAL 5KPSI WS TOPRPR -28 2" NPT Model Number BA02T5T01A1 BA02T5T03A1 BA02T5T04A1 BA02T5T06A1 BA02T5T08A1 BA02T5T28A1 BA02T5T01W1 BA02T5T03W1 BA02T5T04W1 BA02T5T06W1 BA02T5T08W1 BA02T5T28W1 BA02T5F01A1 BA02T5F03A1 BA02T5F04A1 BA02T5F06A1 BA02T5F08A1 BA02T5F28A1 BA02T5F01W1 BA02T5F03W1 BA02T5F04W1 BA02T5F06W1 BA02T5F08W1 BA02T5F28W1 BA05T5U01A1 BA05T5U03A1 BA05T5U04A1 BA05T5U06A1 BA05T5U08A1 BA05T5U28A1 BA05T5U01W1 BA05T5U03W1 BA05T5U04W1 BA05T5U06W1 BA05T5U08W1 BA05T5U28W1 BA05T5T01A1 BA05T5T03A1 BA05T5T04A1 BA05T5T06A1 BA05T5T08A1 BA05T5T28A1 BA05T5T01W1 BA05T5T03W1 BA05T5T04W1 BA05T5T06W1 BA05T5T08W1 BA05T5T28W1 BA05T5F01A1 BA05T5F03A1 BA05T5F04A1 BA05T5F06A1 BA05T5F08A1 BA05T5F28A1 BA05T5F01W1 BA05T5F03W1 BA05T5F04W1 BA05T5F06W1 BA05T5F08W1 BA05T5F28W1 BA10T5U01A1 BA10T5U03A1 BA10T5U04A1 BA10T5U06A1 BA10T5U08A1 BA10T5U28A1 BA10T5U01W1 Description BA 2.5" SAE BA 2.5" SAE BA 2.5GAL 5KPSI WS TOPRPR -3 1.5" SAE BA 2.5"SAE BA 5GAL 3KPSI WS TOPRPR -1 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -3 1.5" SAE BA 2.5" SAE BA 2.5GAL 5KPSI WS TOPRPR -3 2" NPT BA 2.5GAL 5KPSI OS TOPRPR -8 1.75"SAE BA 2.5" SAE BA 5GAL 5KPSI OS TOPRPR -4 1.5GAL 3KPSI OS -1 4BLT BA 11GAL 3KPSI OS -1 4BLT BA 11GAL 3KPSI OS TOPRPR -1 2" 4BLT KLVNT 2.5GAL 5KPSI WS TOPRPR -8 2" 4 BOLT BA 2.5GAL 3KPSI WS -28 1.5GAL 5KPSI OS TOPRPR -28 1.25" SAE BA 1GAL 5KPSI WS -4 1.5GAL 5KPSI OS TOPRPR -1 2" 4 BOLT BA 2.5GAL 5KPSI WS TOPRPR -3 2" 4 BOLT BA 2.5"SAE BA 10GAL 3KPSI WS -28 1.5" SAE BA 2.5GAL 5KPSI WS TOPRPR -6 2" NPT BA 2.5GAL -8 1"SAE (FIBERGLAS) KLVNT 5GAL -1 1"SAE (FIBERGLAS) KLVNT 5GAL -6 1"SAE (FIBERGLAS) KLVNT 5GAL -8 1"SAE (FIBERGLAS) KLVNT 10GAL -1 1"SAE (FIBERGLAS) KLVNT 10GAL -6 1"SAE (FIBERGLAS) KLVNT 10GAL -8 1"SAE (FIBERGLAS) BA 2.5" SAE BA 2.5GAL 5KPSI OS TOPRPR -3 2" 4 BOLT BA 2.5GAL 5KPSI WS TOPRPR -8 1.5GAL -6 1"SAE (FIBERGLAS) KLVNT 2.5GAL 5KPSI OS TOPRPR -4 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -3 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -1 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -3 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -4 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -6 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -8 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -28 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -1 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -3 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -4 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -6 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -8 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -28 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -1 2" NPT BA 10GAL 5KPSI OS TOPRPR -3 2" NPT BA 10GAL 5KPSI OS TOPRPR -4 2" NPT BA 10GAL 5KPSI OS TOPRPR -6 2" NPT BA 10GAL 5KPSI OS TOPRPR -8 2" NPT BA 10GAL 5KPSI OS TOPRPR -28 2" NPT BA 10GAL 5KPSI WS TOPRPR -1 2" NPT 190 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.25" SAE BA 15GAL 3KPSI OS -1 4BLT BA 15GAL 3KPSI OS -3 4BLT BA 15GAL 3KPSI OS -4 4BLT BA 15GAL 3KPSI OS -6 4BLT BA 15GAL 3KPSI OS -8 4BLT BA 15GAL 3KPSI OS -28 4BLT KLVNT 20GAL -1 1.5"SAE BA 11GAL 3KPSI WS TOPRPR -1 1.75"SAE BA 1QT 3KPSI WS -4 .5"SAE BA 11GAL 3KPSI WS TOPRPR -4 1.5" SAE BA 2.5" SAE BA 5GAL 5KPSI OS TOPRPR -6 1.5GAL 3KPSI WS -4 1.5GAL 5KPSI OS TOPRPR -1 1.5"SAE BA 2.5"SAE BA 10GAL 3KPSI WS -1 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -4 1.5GAL 5KPSI OS TOPRPR -28 2" 4 BOLT BA 2.5GAL 5KPSI WS TOPRPR -8 2" NPT BA 2.5"SAE BA 15GAL 3KPSI WS TOPRPR -1 1.5GAL 5KPSI OS TOPRPR -8 2" 4 BOLT BA 2.5" SAE BA 2.5GAL 5KPSI WS TOPRPR -4 2" 4 BOLT BA 2.5"SAE BA 2.Catalog HY10-1630/US EPN to Model Number Crossover EPN 854533 854570 854572 854576 855090 855093 855100 855103 855110 855113 855120 855123 855125 855126 855130 855133 855136 855140 855143 855150 855153 855160 855163 855170 855173 855180 855183 855190 855193 855330 855333 856220 856221 856222 856223 856224 856225 856940 856943 856944 857200 857205 857330 857700 857710 857720 857780 857783 857784 857790 857793 857794 857800 857803 857804 858490 858491 858492 858493 858494 858496 858500 858501 858502 858503 858504 858506 Greer Accumulators Model Number Conversion Table EPN 858510 858511 858512 858513 858514 858516 858520 858521 858522 858523 858524 858526 858530 858531 858532 858533 858534 858536 858540 858541 858542 858543 858544 858546 858550 858551 858552 858553 858554 858556 858560 858561 858562 858563 858564 858566 858570 858571 858572 858573 858574 858576 858580 858581 858582 858583 858584 858586 858590 858591 858592 858593 858594 858596 858600 858601 858602 858603 858604 858606 858610 858611 858612 858613 858614 858616 858620 Model Number BA15B3T04W1 BA10B3F01A1 BA10B3F04A1 BA10B3F28A1 BAC10B3T01W1 BAC10B3TO4W1 BA001B3T01W1 BA001B3T04W1 BA002B3T01W1 BA002B3T04W1 BA02B3T01W1 BA02B3T04W1 BA02B3T08W1 BA02B3T28W1 BA10B3T01W1 BA10B3T04W1 BA10B3T28W1 BA11B3T01W1 BA11B3T04W1 BA02T3T01W1 BA02T3T04W1 BA05T3T01W1 BA05T3T04W1 BA10T3T01W1 BA10T3T04W1 BA11T3T01W1 BA11T3T04W1 BA15T3T01W1 BA15T3T04W1 BA01B5T01W1 BA01B5T04W1 BA15B3F01A1 BA15B3F03A1 BA15B3F04A1 BA15B3F06A1 BA15B3F08A1 BA15B3F28A1 KV20F0T01A1 KV20F0T06A1 KV20F0T08A1 BA10T3F01A1 BA10T3F08A1 BA15T3F01A1 BA02B3F01A1 BA11B3F01A1 BA11T3F01A1 KV02F0T01A1 KV02F0T06A1 KV02F0T08A1 KV05F0T01A1 KV05F0T06A1 KV05F0T08A1 KV10F0T01A1 KV10F0T06A1 KV10F0T08A1 BA02T5U01A1 BA02T5U03A1 BA02T5U04A1 BA02T5U06A1 BA02T5U08A1 BA02T5U28A1 BA02T5U01W1 BA02T5U03W1 BA02T5U04W1 BA02T5U06W1 BA02T5U08W1 BA02T5U28W1 Description BA 15GAL 3KPSI WS -4 1.75"SAE BA 1QT 3KPSI WS -1 .5GAL 5KPSI WS TOPRPR -28 1.5"SAE BA 2.5GAL 5KPSI OS TOPRPR -4 2" 4 BOLT BA 2.5" SAE BA 5GAL 5KPSI WS TOPRPR -8 1.5GAL 3KPSI WS TOPRPR -1 1.5GAL 3KPSI WS -1 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -28 1.5"SAE BA 2.5GAL 5KPSI OS TOPRPR -8 2" NPT BA 2.5GAL 3KPSI WS TOPRPR -4 1.5GAL 5KPSI WS TOPRPR -6 1.5"SAE BA 11GAL 3KPSI WS -4 1.5"SAE BA 10CI 3KPSI WS -4 .5"SAE BA 10GAL 3KPSI WS TOPRPR -4 1.5"SAE BA 15GAL 3KPSI WS TOPRPR -4 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -28 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -8 1.5GAL 5KPSI OS TOPRPR -28 2" NPT BA 2.5"SAE BA 10GAL 3KPSI WS TOPRPR -1 1. Illinois USA .5" SAE BA 5GAL 5KPSI WS TOPRPR -1 1.5" SAE BA 2.75"SAE BA 1PT 3KPSI WS -4 .5GAL 5KPSI OS TOPRPR -6 2" 4 BOLT BA 2.5GAL 5KPSI WS TOPRPR -6 2" 4 BOLT BA 2.5GAL 5KPSI WS TOPRPR -4 2" NPT BA 2.5GAL 5KPSI OS TOPRPR -1 2" NPT BA 2.5"SAE (FIBERGLAS) KLVNT 20GAL -6 1.5" SAE BA 2.5"SAE BA 2.5GAL 5KPSI OS TOPRPR -4 2" NPT BA 2.5GAL 5KPSI OS TOPRPR -6 1. 5GAL 5KPSI OS -3 2" NPT BA 2.5GAL 5KPSI WS -28 2" NPT BA 2.5" SAE BA 10GAL 5KPSI WS TOPRPR -4 1.5" SAE BA 10GAL 5KPSI WS TOPRPR -3 1. Illinois USA .5" SAE BA 15GAL 5KPSI OS TOPRPR -8 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -6 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -8 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -3 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -4 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -1 1.5GAL 5KPSI OS -8 1.5GAL 5KPSI OS -8 2" NPT BA 2.5" SAE BA 15GAL 5KPSI OS TOPRPR -6 1.5" SAE BA 2.5GAL 5KPSI OS -6 2" NPT BA 2.5" SAE BA 2.5" SAE BA 10GAL 5KPSI WS TOPRPR -8 1.5GAL 5KPSI WS -4 2" NPT BA 2.5" SAE BA 10GAL 5KPSI OS TOPRPR -6 1.5GAL 5KPSI OS -4 1.5GAL 5KPSI OS -1 2" NPT BA 2.5" SAE 191 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5GAL 5KPSI OS -28 2" NPT BA 2.5" SAE BA 15GAL 5KPSI WS TOPRPR -28 1.5GAL 5KPSI OS -1 1.5GAL 5KPSI WS -3 2" NPT BA 2.5GAL 5KPSI OS -4 2" NPT BA 2.5" SAE BA 10GAL 5KPSI OS TOPRPR -1 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -3 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -4 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -6 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -8 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -28 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -1 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -3 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -4 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -6 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -8 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -28 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -1 2" NPT BA 15GAL 5KPSI OS TOPRPR -3 2" NPT BA 15GAL 5KPSI OS TOPRPR -4 2" NPT BA 15GAL 5KPSI OS TOPRPR -6 2" NPT BA 15GAL 5KPSI OS TOPRPR -8 2" NPT BA 15GAL 5KPSI OS TOPRPR -28 2" NPT BA 15GAL 5KPSI WS TOPRPR -1 2" NPT BA 15GAL 5KPSI WS TOPRPR -3 2" NPT BA 15GAL 5KPSI WS TOPRPR -4 2" NPT BA 15GAL 5KPSI WS TOPRPR -6 2" NPT BA 15GAL 5KPSI WS TOPRPR -8 2" NPT BA 15GAL 5KPSI WS TOPRPR -28 2" NPT BA 15GAL 5KPSI OS TOPRPR -1 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -1 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -3 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -4 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -6 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -8 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -28 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -1 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -3 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -4 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -6 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -8 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -28 2" 4 BOLT SRGKN 25GAL 275PSI WS -1 4" FLG FM SRGKN 40GAL 275PSI WS -1 4" FLG FM Model Number SK80W3FB01F1 SK100W3FB01F1 SK120W3FB01F1 SK25W3FC01F1 SK40W3FC01F1 SK80W3FC01F1 SK100W3FC01F1 SK120W3FC01F1 SK25W3FD01F1 SK40W3FD01F1 SK80W3FD01F1 SK100W3FD01F1 SK120W3FD01F1 SK25W3FE01F1 SK40W3FE01F1 SK80W3FE01F1 SK100W3FE01F1 SK120W3FE01F1 SK25W4PB01F1 SK25W5PB01A1 SK25W53PB04A1 SK25W5PB08A1 SK25W5PB28A1 SK40W4PB01F1 SK40W5PB01A1 SK40W5PB04A1 SK40W5PB08A1 SK40W5PB28A1 SK80W4PB01F1 SK80W5PB01A1 SK80W5PB04A1 SK80W5PB08A1 SK100W4PB01F1 SK100W5PB01A1 SK100W5PB04A1 SK100W5PB08A1 SK120W4PB01F1 SK120W5PB01A1 SK120W5PB04A1 SK120W5PB08A1 SK25W4PC01F1 SK40W4PC01F1 SK80W4PC01F1 SK100W4PC01F1 SK120W4PC01F1 SK25W4PD01F1 SK40W4PD01F1 SK80W4PD01F1 SK100W4PD01F1 SK120W4PD01F1 BA02B5U01A1 BA02B5U03A1 BA02B5U04A1 BA02B5U06A1 BA02B5U08A1 BA02B5U28A1 BA02B5U01W1 BA02B5U03W1 BA02B5U04W1 BA02B5U06W1 BA02B5U08W1 BA02B5U28W1 BA02B5T01A1 BA02B5T03A1 BA02B5T04A1 BA02B5T06A1 BA02B5T08A1 Description SRGKN 80GAL 275PSI WS -1 4" FLG FM SRGKN 100GAL 275PSI WS -1 4" FLG FM SRGKN 120GAL 275PSI WS -1 4" FLG FM SRGKN 25GAL 275PSI WS -1 6" FLG FM SRGKN 40GAL 275PSI WS -1 6" FLG FM SRGKN 80GAL 275PSI WS -1 6" FLG FM SRGKN 100GAL 275PSI WS -1 6" FLG FM SRGKN 120GAL 275PSI WS -1 6" FLG FM SRGKN 25GAL 275PSI WS -1 8" FLG FM SRGKN 40GAL 275PSI WS -1 8" FLG FM SRGKN 80GAL 275PSI WS -1 8" FLG FM SRGKN 100GAL 275PSI WS -1 8" FLG FM SRGKN 120GAL 275PSI WS -1 8" FLG FM SRGKN 25GAL 275PSI WS -1 10" FLG FM SRGKN 40GAL 275PSI WS -1 10" FLG FM SRGKN 80GAL 275PSI WS -1 10" FLG FM SRGKN 100GAL 275PSI WS -1 10" FLG FM SRGKN 120GAL 275PSI WS -1 10" FLG FM SRGKN 25GAL 400PSI -1 4" FLG FM SRGKN 25GAL 500PSI WS -1 4" FLG SRGKN 25GAL 500PSI WS -4 4" FLG SRGKN 25GAL 500PSI WS -8 4" FLG SRGKN 25GAL 500PSI WS -28 4" FLG SRGKN 40GAL 400PSI -1 4" FLG FM SRGKN 40GAL 500PSI WS -1 4" FLG SRGKN 40GAL 500PSI WS -4 4" FLG SRGKN 40GAL 500PSI WS -8 4" FLG SRGKN 40GAL 500PSI WS -28 4" FLG SRGKN 80GAL 400PSI -1 4" FLG FM SRGKN 80GAL 500PSI WS -1 4" FLG SRGKN 80GAL 500PSI WS -4 4" FLG SRGKN 80GAL 500PSI WS -8 4" FLG SRGKN 100GAL 400PSI -1 4" FLG FM SRGKN 100GAL 500PSI WS -1 4" FLG SRGKN 100GAL 500PSI WS -4 4" FLG SRGKN 100GAL 500PSI WS -8 4" FLG SRGKN 120GAL 400PSI -1 4" FLG FM SRGKN 120GAL 500PSI WS -1 4" FLG SRGKN 120GAL 500PSI WS -4 4" FLG SRGKN 120GAL 500PSI WS -8 4" FLG SRGKN 25GAL 400PSI -1 6" FLG FM SRGKN 40GAL 400PSI -1 6" FLG FM SRGKN 80GAL 400PSI -1 6" FLG FM SRGKN 100GAL 400PSI -1 6" FLG FM SRGKN 120GAL 400PSI -1 6" FLG FM SRGKN 25GAL 400PSI -1 8" FLG FM SRGKN 40GAL 400PSI -1 8" FLG FM SRGKN 80GAL 400PSI -1 8" FLG FM SRGKN 100GAL 400PSI -1 8" FLG FM SRGKN 120GAL 400PSI -1 8" FLG FM BA 2.5" SAE BA 2.5" SAE BA 15GAL 5KPSI OS TOPRPR -4 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -28 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -28 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -3 1.5" SAE BA 10GAL 5KPSI WS TOPRPR -6 1.5GAL 5KPSI WS -1 2" NPT BA 2.5" SAE BA 10GAL 5KPSI WS TOPRPR -1 1.5" SAE BA 10GAL 5KPSI WS TOPRPR -28 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -4 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -8 1.5GAL 5KPSI WS -6 2" NPT BA 2.5GAL 5KPSI OS -3 1.5GAL 5KPSI WS -8 2" NPT BA 2.5" SAE BA 2.5GAL 5KPSI OS -6 1.Catalog HY10-1630/US EPN to Model Number Crossover EPN 858621 858622 858623 858624 858626 858630 858631 858632 858633 858634 858636 858640 858641 858642 858643 858644 858646 858650 858651 858652 858653 858654 858656 858660 858661 858662 858663 858664 858666 858670 858671 858672 858673 858674 858676 858680 858681 858682 858683 858684 858686 858690 858691 858692 858693 858694 858696 858700 858701 858702 858703 858704 858706 858710 858711 858712 858713 858714 858716 858720 858721 858722 858723 858724 858726 859950 859960 Greer Accumulators Model Number Conversion Table EPN 859970 859980 859990 860000 860010 860020 860030 860040 860050 860060 860070 860080 860090 860100 860110 860120 860130 860140 860150 860151 860152 860154 860156 860160 860161 860162 860164 860166 860170 860171 860172 860174 860180 860181 860182 860184 860190 860191 860192 860194 860200 860210 860220 860230 860240 860250 860260 860270 860280 860290 863000 863001 863002 863003 863004 863006 863010 863011 863012 863013 863014 863016 863020 863021 863022 863023 863024 Model Number BA10T5U03W1 BA10T5U04W1 BA10T5U06W1 BA10T5U08W1 BA10T5U28W1 BA10T5T01A1 BA10T5T03A1 BA10T5T04A1 BA10T5T06A1 BA10T5T08A1 BA10T5T28A1 BA10T5T01W1 BA10T5T03W1 BA10T5T04W1 BA10T5T06W1 BA10T5T08W1 BA10T5T28W1 BA10T5F01A1 BA10T5F03A1 BA10T5F04A1 BA10T5F06A1 BA10T5F08A1 BA10T5F28A1 BA10T5F01W1 BA10T5F03W1 BA10T5F04W1 BA10T5F06W1 BA10T5F08W1 BA10T5F28W1 BA15T5U01A1 BA15T5U03A1 BA15T5U04A1 BA15T5U06A1 BA15T5U08A1 BA15T5U28A1 BA15T5U01W1 BA15T5U03W1 BA15T5U04W1 BA15T5U06W1 BA15T5U08W1 BA15T5U28W1 BA15T5T01A1 BA15T5T03A1 BA15T5T04A1 BA15T5T06A1 BA15T5T08A1 BA15T5T28A1 BA15T5T01W1 BA15T5T03W1 BA15T5T04W1 BA15T5T06W1 BA15T5T08W1 BA15T5T28W1 BA15T5F01A1 BA15T5F03A1 BA15T5F04A1 BA15T5F06A1 BA15T5F08A1 BA15T5F28A1 BA15T5F01W1 BA15T5F03W1 BA15T5F04W1 BA15T5F06W1 BA15T5F08W1 BA15T5F28W1 SK25W3FB01F1 SK40W3FB01F1 Description BA 10GAL 5KPSI WS TOPRPR -3 2" NPT BA 10GAL 5KPSI WS TOPRPR -4 2" NPT BA 10GAL 5KPSI WS TOPRPR -6 2" NPT BA 10GAL 5KPSI WS TOPRPR -8 2" NPT BA 10GAL 5KPSI WS TOPRPR -28 2" NPT BA 10GAL 5KPSI OS TOPRPR -1 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -3 1. 5GAL 5KPSI OS -1 1.5GAL 5KPSI WS -1 1.5GAL 5KPSI WS -1 1.5" 4 BOLT BA 15GAL 5KPSI WS -4 1.5" 4 BOLT BA 15GAL 5KPSI WS -6 1.5GAL 5KPSI WS -4 1.5" 4 BOLT BA 10GAL 5KPSI OS -28 1.5" SAE BA 5GAL 5KPSI OS -8 1.5" 4 BOLT BA 5GAL 5KPSI OS -4 1.5" SAE BA 2.5" SAE BA 15GAL 5KPSI WS -1 1.5GAL 5KPSI OS -4 1.5" SAE BA 15GAL 5KPSI OS -6 1.5" 4 BOLT BA 5GAL 5KPSI WS -1 1.5" SAE BA 5GAL 5KPSI WS -3 1.5" 4 BOLT BA 10GAL 5KPSI WS -4 1.5" SAE BA 10GAL 5KPSI WS -8 1.5" SAE BA 15GAL 5KPSI OS -1 1.5" 4 BOLT BA 10GAL 5KPSI OS -4 1.5GAL 5KPSI OS -6 1.5" SAE BA 15GAL 5KPSI OS -3 1.5" SAE BA 10GAL 5KPSI WS -4 1.5" 4 BOLT BA 10GAL 5KPSI OS -1 2" NPT BA 10GAL 5KPSI OS -3 2" NPT BA 10GAL 5KPSI OS -4 2" NPT BA 10GAL 5KPSI OS -6 2" NPT BA 10GAL 5KPSI OS -8 2" NPT BA 10GAL 5KPSI OS -28 2" NPT BA 10GAL 5KPSI WS -1 2" NPT BA 10GAL 5KPSI WS -3 2" NPT BA 10GAL 5KPSI WS -4 2" NPT BA 10GAL 5KPSI WS -6 2" NPT BA 10GAL 5KPSI WS -8 2" NPT BA 10GAL 5KPSI WS -28 2" NPT Model Number BA10B5T01A1 BA10B5T03A1 BA10B5T04A1 BA10B5T06A1 BA10B5T08A1 BA10B5T28A1 BA10B5T01W1 BA10B5T03W1 BA10B5T04W1 BA10B5T06W1 BA10B5T08W1 BA10B5T28W1 BA10B5F01A1 BA10B5F03A1 BA10B5F04A1 BA10B5F06A1 BA10B5F08A1 BA10B5F28A1 BA10B5F01W1 BA10B5F03W1 BA10B5F04W1 BA10B5F06W1 BA10B5F08W1 BA10B5F28W1 BA15B5U01A1 BA15B5U03A1 BA15B5U04A1 BA15B5U06A1 BA15B5U08A1 BA15B5U28A1 BA15B5U01W1 BA15B5U03W1 BA15B5U04W1 BA15B5U06W1 BA15B5U08W1 BA15B5U28W1 BA15B5T01A1 BA15B5T03A1 BA15B5T04A1 BA15B5T06A1 BA15B5T08A1 BA15B5T28A1 BA15B5T01W1 BA15B5T03W1 BA15B5T04W1 BA15B5T06W1 BA15B5T08W1 BA15B5T28W1 BA15B5F01A1 BA15B5F03A1 BA15B5F04A1 BA15B5F06A1 BA15B5F08A1 BA15B5F28A1 BA15B5F01W1 BA15B5F03W1 BA15B5F04W1 BA15B5F06W1 BA15B5F08W1 BA15B5F28W1 SK02W5PA01F1 SK05W5PA01F1 SK10W5PA01F1 SK80W5PB28A1 SK120W5PB28A1 SK100W5PB28A1 SK02A3FA01A1 Description BA 10GAL 5KPSI OS -1 1.5" SAE BA 5GAL 5KPSI WS -6 1.5" 4 BOLT BA 10GAL 5KPSI WS -28 1.5" SAE BA 15GAL 5KPSI OS -28 1.5GAL 275PSI OS -1 3" FLG 192 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5" 4 BOLT BA 2.5" 4 BOLT BA 15GAL 5KPSI OS -28 1.5" 4 BOLT BA 5GAL 5KPSI OS -28 1.5" SAE BA 10GAL 5KPSI WS -3 1.5" 4 BOLT BA 15GAL 5KPSI WS -1 1.5" 4 BOLT BA 10GAL 5KPSI WS -6 1.5" SAE BA 5GAL 5KPSI OS -3 1.5" SAE BA 5GAL 5KPSI OS -1 1. Illinois USA .5GAL 5KPSI WS -8 1.5GAL 5KPSI WS -4 1.5" 4 BOLT BA 5GAL 5KPSI WS -3 1.5" 4 BOLT BA 5GAL 5KPSI OS -6 1.5" 4 BOLT BA 15GAL 5KPSI OS -8 1.5" 4 BOLT BA 5GAL 5KPSI WS -28 1.5" 4 BOLT BA 2.5GAL 5KPSI WS -28 1.5" SAE BA 10GAL 5KPSI OS -8 1.5" 4 BOLT BA 2.5" SAE BA 5GAL 5KPSI OS -4 1.5" SAE BA 10GAL 5KPSI WS -1 1.5" 4 BOLT BA 5GAL 5KPSI OS -1 2" NPT BA 5GAL 5KPSI OS -3 2" NPT BA 5GAL 5KPSI OS -4 2" NPT BA 5GAL 5KPSI OS -6 2" NPT BA 5GAL 5KPSI OS -8 2" NPT BA 5GAL 5KPSI OS -28 2" NPT BA 5GAL 5KPSI WS -1 2" NPT BA 5GAL 5KPSI WS -3 2" NPT BA 5GAL 5KPSI WS -4 2" NPT BA 5GAL 5KPSI WS -6 2" NPT BA 5GAL 5KPSI WS -8 2" NPT BA 5GAL 5KPSI WS -28 2" NPT BA 5GAL 5KPSI OS -1 1.5" SAE BA 2.5" 4 BOLT BA 5GAL 5KPSI OS -3 1.5" SAE BA 15GAL 5KPSI WS -4 1.5" 4 BOLT BA 2.5" SAE BA 10GAL 5KPSI WS -28 1.5" SAE BA 15GAL 5KPSI WS -28 1.5" 4 BOLT BA 2.5" SAE BA 15GAL 5KPSI OS -4 1.5" SAE BA 2.5GAL 500PSI -1 3" FLG FM SRGKN 5GAL 500PSI -1 3" FLG FM SRGKN 10GAL 500PSI -1 3" FLG FM SRGKN 80GAL 500PSI WS -28 4" FLG SRGKN 120GAL 500PSI WS -28 4" FLG SRGKN 100GAL 500PSI WS -28 4" FLG SRGKN 2.5" SAE BA 15GAL 5KPSI OS -8 1.5GAL 5KPSI WS -3 1.5" 4 BOLT BA 2.5" SAE BA 2.5" 4 BOLT BA 15GAL 5KPSI OS -4 1.5" SAE BA 10GAL 5KPSI OS -1 1.5" SAE BA 2.5" 4 BOLT BA 15GAL 5KPSI WS -3 1.5" 4 BOLT BA 2.5" SAE BA 2.5GAL 5KPSI OS -8 1.5" SAE BA 10GAL 5KPSI OS -28 1.5" 4 BOLT BA 10GAL 5KPSI WS -8 1.5" SAE BA 15GAL 5KPSI WS -8 1.5" SAE BA 5GAL 5KPSI WS -1 1.5GAL 5KPSI WS -3 1.5" 4 BOLT BA 10GAL 5KPSI WS -3 1.5GAL 5KPSI OS -28 1.5" SAE BA 2.5GAL 5KPSI OS -28 1.5" 4 BOLT BA 15GAL 5KPSI OS -1 2" NPT BA 15GAL 5KPSI OS -3 2" NPT BA 15GAL 5KPSI OS -4 2" NPT BA 15GAL 5KPSI OS -6 2" NPT BA 15GAL 5KPSI OS -8 2" NPT BA 15GAL 5KPSI OS -28 2" NPT BA 15GAL 5KPSI WS -1 2" NPT BA 15GAL 5KPSI WS -3 2" NPT BA 15GAL 5KPSI WS -4 2" NPT BA 15GAL 5KPSI WS -6 2" NPT BA 15GAL 5KPSI WS -8 2" NPT BA 15GAL 5KPSI WS -28 2" NPT BA 15GAL 5KPSI OS -1 1.5" 4 BOLT BA 10GAL 5KPSI OS -8 1.Catalog HY10-1630/US EPN to Model Number Crossover EPN 863026 863030 863031 863032 863033 863034 863036 863040 863041 863042 863043 863044 863046 863050 863051 863052 863053 863054 863056 863060 863061 863062 863063 863064 863066 863070 863071 863072 863073 863074 863076 863080 863081 863082 863083 863084 863086 863090 863091 863092 863093 863094 863096 863100 863101 863102 863103 863104 863106 863110 863111 863112 863113 863114 863116 863120 863121 863122 863123 863124 863126 863130 863131 863132 863133 863134 863136 Greer Accumulators Model Number Conversion Table EPN 863140 863141 863142 863143 863144 863146 863150 863151 863152 863153 863154 863156 863160 863161 863162 863163 863164 863166 863170 863171 863172 863173 863174 863176 863180 863181 863182 863183 863184 863186 863190 863191 863192 863193 863194 863196 863200 863201 863202 863203 863204 863206 863210 863211 863212 863213 863214 863216 863220 863221 863222 863223 863224 863226 863230 863231 863232 863233 863234 863236 863737 863738 863739 863741 863742 863762 863770 Model Number BA02B5T28A1 BA02B5T01W1 BA02B5T03W1 BA02B5T04W1 BA02B5T06W1 BA02B5T08W1 BA02B5T28W1 BA02B5F01A1 BA02B5F03A1 BA02B5F04A1 BA02B5F06A1 BA02B5F08A1 BA02B5F28A1 BA02B5F01W1 BA02B5F03W1 BA02B5F04W1 BA02B5F06W1 BA02B5F08W1 BA02B5F28W1 BA05B5U01A1 BA05B5U03A1 BA05B5U04A1 BA05B5U06A1 BA05B5U08A1 BA05B5U28A1 BA05B5U01W1 BA05B5U03W1 BA05B5U04W1 BA05B5U06W1 BA05B5U08W1 BA05B5U28W1 BA05B5T01A1 BA05B5T03A1 BA05B5T04A1 BA05B5T06A1 BA05B5T08A1 BA05B5T28A1 BA05B5T01W1 BA05B5T03W1 BA05B5T04W1 BA05B5T06W1 BA05B5T08W1 BA05B5T28W1 BA05B5F01A1 BA05B5F03A1 BA05B5F04A1 BA05B5F06A1 BA05B5F08A1 BA05B5F28A1 BA05B5F01W1 BA05B5F03W1 BA05B5F04W1 BA05B5F06W1 BA05B5F08W1 BA05B5F28W1 BA10B5U01A1 BA10B5U03A1 BA10B5U04A1 BA10B5U06A1 BA10B5U08A1 BA10B5U28A1 BA10B5U01W1 BA10B5U03W1 BA10B5U04W1 BA10B5U06W1 BA10B5U08W1 BA10B5U28W1 Description BA 2.5" 4 BOLT BA 10GAL 5KPSI OS -6 1.5" 4 BOLT BA 15GAL 5KPSI WS -28 1.5" SAE BA 10GAL 5KPSI WS -6 1.5" 4 BOLT BA 5GAL 5KPSI WS -6 1.5" 4 BOLT BA 2.5" 4 BOLT BA 2.5GAL 5KPSI OS -3 1.5GAL 5KPSI WS -28 1.5" SAE BA 5GAL 5KPSI WS -28 1.5" 4 BOLT SRGKN 2.5" 4 BOLT BA 10GAL 5KPSI OS -3 1.5" 4 BOLT BA 2.5" SAE BA 5GAL 5KPSI OS -6 1.5GAL 5KPSI WS -8 1.5" SAE BA 5GAL 5KPSI WS -4 1.5" 4 BOLT BA 5GAL 5KPSI WS -4 1.5" SAE BA 5GAL 5KPSI OS -28 1.5" SAE BA 10GAL 5KPSI OS -6 1.5" 4 BOLT BA 15GAL 5KPSI OS -3 1.5" 4 BOLT BA 15GAL 5KPSI WS -8 1.5" 4 BOLT BA 2.5GAL 5KPSI WS -6 1.5" SAE BA 10GAL 5KPSI OS -4 1.5" 4 BOLT BA 5GAL 5KPSI WS -8 1.5" 4 BOLT BA 15GAL 5KPSI OS -6 1.5" SAE BA 5GAL 5KPSI WS -8 1.5" 4 BOLT BA 5GAL 5KPSI OS -8 1.5GAL 5KPSI WS -6 1.5" SAE BA 15GAL 5KPSI WS -3 1.5" SAE BA 15GAL 5KPSI WS -6 1.5" 4 BOLT BA 10GAL 5KPSI WS -1 1.5" SAE BA 10GAL 5KPSI OS -3 1. 5GAL 500PSI WS -28 3" FLG SRGKN 5GAL 500PSI WS -1 3" FLG SRGKN 5GAL 500PSI WS -4 3" FLG SRGKN 5GAL 500PSI WS -8 3" FLG SRGKN 5GAL 500PSI WS -28 3" FLG SRGKN 10GAL 500PSI WS -1 3" FLG SRGKN 10GAL 500PSI WS -4 3" FLG SRGKN 10GAL 500PSI WS -8 3" FLG SRGKN 10GAL 500PSI WS -28 3" FLG SRGKN 25GAL 275PSI OS -1 4" FLG SRGKN 40GAL 275PSI OS -1 4" FLG SRGKN 80GAL 275PSI OS -1 4" FLG SRGKN 100GAL 275PSI OS -1 4" FLG SRGKN 120GAL 275PSI OS -1 4" FLG SRGKN 25GAL 275PSI OS -1 6" FLG SRGKN 40GAL 275PSI OS -1 6" FLG SRGKN 80GAL 275PSI OS -1 6" FLG SRGKN 100GAL 275PSI OS -1 6" FLG SRGKN 120GAL 275PSI OS -1 6" FLG SRGKN 25GAL 275PSI OS -1 8" FLG SRGKN 40GAL 275PSI OS -1 8" FLG SRGKN 80GAL 275PSI OS -1 8" FLG SRGKN 100GAL 275PSI OS -1 8" FLG SRGKN 120GAL 275PSI OS -1 8" FLG SRGKN 25GAL 275PSI OS -1 10" FLG SRGKN 40GAL 275PSI OS -1 10" FLG SRGKN 80GAL 275PSI OS -1 10" FLG SRGKN 100GAL 275PSI OS -1 10" FLG SRGKN 120GAL 275PSI OS -1 10" FLG SRGKN 25GAL 500PSI OS -1 4" FLG SRGKN 40GAL 500PSI OS -1 4" FLG SRGKN 80GAL 500PSI OS -1 4" FLG SRGKN 100GAL 500PSI OS -1 4" FLG SRGKN 120GAL 500PSI OS -1 4" FLG SRGKN 25GAL 500PSI OS -4 4" FLG SRGKN 40GAL 500PSI OS -4 4" FLG SRGKN 80GAL 500PSI OS -4 4" FLG SRGKN 100GAL 500PSI OS -4 4" FLG SRGKN 120GAL 500PSI OS -4 4" FLG SRGKN 25GAL 500PSI OS -8 4" FLG SRGKN 40GAL 500PSI OS -8 4" FLG Model Number SK80A5PB08A1 SK100A5PB08A1 SK120A5PB08A1 SK25A5PB28A1 SK40W5PB28A1 SK80A5PB28A1 SK100A5PB28A1 SK120A5PB28A1 Description SRGKN 80GAL 500PSI OS -8 4" FLG SRGKN 100GAL 500PSI OS -8 4" FLG SRGKN 120GAL 500PSI OS -8 4" FLG SRGKN 25GAL 500PSI OS -28 4" FLG SRGKN 40GAL 500PSI OS -28 4" FLG SRGKN 80GAL 500PSI OS -28 4" FLG SRGKN 100GAL 500PSI OS -28 4" FLG SRGKN 120GAL 500PSI OS -28 4" FLG 193 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5GAL 500PSI OS -1 3" FLG SRGKN 2.5GAL 275PSI OS -4 3" FLG SRGKN 2.5GAL 500PSI OS -4 3" FLG SRGKN 2.5GAL 275PSI OS -8 3" FLG SRGKN 2.5GAL 500PSI WS -1 3" FLG SRGKN 2.5GAL 275PSI OS -28 3" FLG SRGKN 5GAL 275PSI OS -1 3" FLG SRGKN 5GAL 275PSI OS -4 3" FLG SRGKN 5GAL 275PSI OS -8 3" FLG SRGKN 5GAL 275PSI OS -28 3" FLG SRGKN 10GAL 275PSI OS -1 3" FLG SRGKN 10GAL 275PSI OS -4 3" FLG SRGKN 10GAL 275PSI OS -8 3" FLG SRGKN 10GAL 275PSI OS -28 3" FLG SRGKN 2.5GAL 500PSI WS -8 3" FLG SRGKN 2. Illinois USA .5GAL 500PSI OS -8 3" FLG SRGKN 2.5GAL 500PSI OS -28 3" FLG SRGKN 5GAL 500PSI OS -1 3" FLG SRGKN 5GAL 500PSI OS -4 3" FLG SRGKN 5GAL 500PSI OS -8 3" FLG SRGKN 5GAL 500PSI OS -28 3" FLG SRGKN 10GAL 500PSI OS -1 3" FLG SRGKN 10GAL 500PSI OS -4 3" FLG SRGKN 10GAL 500PSI OS -8 3" FLG SRGKN 10GAL 500PSI OS -28 3" FLG SRGKN 2.5GAL 500PSI WS -4 3" FLG SRGKN 2.Catalog HY10-1630/US EPN to Model Number Crossover EPN 863772 863774 863775 863776 863778 863780 863781 863782 863784 863786 863787 863790 863792 863794 863795 863796 863798 863800 863801 863802 863804 863806 863807 863816 863818 863819 863821 863822 863824 863826 863827 863830 863832 863834 863835 863840 863841 863843 863844 863845 863852 863853 863855 863856 863857 863858 863859 863861 863862 863863 863864 863865 863867 863868 863869 863888 863889 863891 863892 863893 863894 863895 863897 863898 863899 863900 863901 Greer Accumulators Model Number Conversion Table EPN 863903 863904 863905 863906 863907 863909 863910 863911 Model Number SK02A3FA04A1 SK02A3FA08A1 SK02A3FA28A1 SK05A3FA01A1 SK05A3FA04A1 SK05A3FA08A1 SK05A3FA28A1 SK10A3FA01A1 SK10A3FA04A1 SK10A3FA08A1 SK10A3FA28A1 SK02A5PA01A1 SK02A5PA04A1 SK02A5PA08A1 SK02A5PA28A1 SK05A5PA01A1 SK05A5PA04A1 SK05A5PA08A1 SK05A5PA28A1 SK10A5PA01A1 SK10A5PA04A1 SK10A5PA08A1 SK10A5PA28A1 SK02W5PA01A1 SK02W5PA04A1 SK02W5PA08A1 SK02W5PA28A1 SK05W5PA01A1 SK05W5PA04A1 SK05W5PA08A1 SK05W5PA28A1 SK10W5PA01A1 SK10W5PA04A1 SK10W5PA08A1 SK10W5PA28A1 SK25A3FB01A1 SK40A3FB01A1 SK80A3FB01A1 SK100A3FB01A1 SK120A3FB01A1 SK25A3FC01A1 SK40A3FC01A1 SK80A3FC01A1 SK100A3FC01A1 SK120A3FC01A1 SK25A3FD01A1 SK40A3FD01A1 SK80A3FD01A1 SK100A3FD01A1 SK120A3FD01A1 SK25A3FE01A1 SK40A3FE01A1 SK80A3FE01A1 SK100A3FE01A1 SK120A3FE01A1 SK25A5PB01A1 SK40A5PB01A1 SK80A5PB01A1 SK100A5PB01A1 SK120A5PB01A1 SK25A5PB04A1 SK40W5PB04A1 SK80A5PB04A1 SK100A5PB04A1 SK120A5PB04A1 SK25A5PB08A1 SK40W5PB08A1 Description SRGKN 2. 25" SAE BA 1GAL 5KPSI WS -1 1.75"NPT BA 1QT 3KPSI OS -8 .75"NPT BA 1PT 3KPSI OS -6 .25" NPT BA 1GAL 5KPSI WS -28 1.5"SAE BA 2.25" NPT BA 1GAL 5KPSI WS -4 1.75"NPT BA 1QT 3KPSI OS -3 .5" 4 BOLT BA 2.5GAL 3KPSI WS HF -28 4"NPT BA 2.5" 4 BOLT BA 2.5GAL 5KPSI OS -3 1.5GAL 3KPSI OS -4 1.5GAL 3KPSI WS -8 1.5GAL 3KPSI WS -3 2"NPT BA 2.75"SAE BA 1QT 3KPSI WS -1 .25"SAE BA 1GAL 3KPSI OS -6 1.5GAL 3KPSI OS -28 2"NPT BA 2.75"NPT BA 1QT 3KPSI WS -3 .75"SAE BA 1PT 3KPSI OS -4 .5GAL 3KPSI WS HF -3 4"NPT BA 2.5" 4 BOLT BA 2.5GAL 3KPSI WS HF -1 4"NPT BA 2.75"SAE BA 1PT 3KPSI WS -1 .5GAL 5KPSI OS -6 1.75"SAE BA 1QT 3KPSI OS -4 .25" SAE BA 1GAL 5KPSI OS -1 1.5GAL 3KPSI OS -8 1.25"NPT BA 1GAL 3KPSI WS -4 1.75"NPT BA 1QT 3KPSI WS -4 .5GAL 3KPSI WS -1 2"NPT BA 2.75"NPT BA 150CI 3KPSI OS -1 1"SAE BA 150CI 3KPSI OS -1 1"NPT BA 150CI 3KPSI WS -1 1"NPT BA 150CI 3KPSI OS -3 1"NPT BA 150CI 3KPSI WS -3 1"NPT BA 150CI 3KPSI OS -4 1"NPT BA 150CI 3KPSI WS -4 1"NPT BA 150CI 3KPSI OS -6 1"NPT BA 150CI 3KPSI WS -6 1"NPT BA 150CI 3KPSI OS -8 1"NPT BA 150CI 3KPSI WS -8 1"NPT BA 150CI 3KPSI OS -28 1"NPT BA 150CI 3KPSI WS -28 1"NPT BA 1GAL 3KPSI OS -1 4BLT BA 1GAL 3KPSI OS -1 1.5GAL 3KPSI OS -3 1.25" NPT BA 1GAL 5KPSI WS -3 1.75"NPT BA 1QT 3KPSI OS -4 .5"SAE BA 2.5GAL 3KPSI WS -6 2"NPT BA 2.25" NPT BA 1GAL 5KPSI WS -8 1.75"SAE BA 1QT 3KPSI OS -6 .75"NPT BA 1QT 3KPSI OS -1 .25"NPT BA 1GAL 5KPSI OS -1 1.25"SAE BA 1GAL 3KPSI WS -28 1.75"NPT BA 1QT 3KPSI OS -6 .25"NPT BA 1GAL 3KPSI OS -6 1.5GAL 3KPSI WS -28 2"NPT BA 2.75"SAE BA 1PT 3KPSI OS -1 .5"SAE BA 2.5GAL 3KPSI OS HF -4 4"NPT BA 2.75"NPT BA 1PT 3KPSI WS -6 .25"SAE BA 1GAL 3KPSI OS -8 1.5GAL 5KPSI WS -3 1.5GAL 3KPSI OS -6 2"NPT BA 2.25"NPT BA 1GAL 3KPSI WS -28 1.75"SAE BA 1QT 3KPSI OS -8 .25"SAE BA 1GAL 3KPSI OS -28 1.5GAL 3KPSI OS HF -3 4"NPT BA 2.5GAL 3KPSI OS -8 2"NPT BA 2.75"NPT BA 1QT 3KPSI WS -6 .5GAL 3KPSI WS HF -4 4"NPT BA 2.25"NPT BA 1GAL 3KPSI WS -1 1.25" NPT BA 1GAL 5KPSI OS -6 1.5GAL 3KPSI WS HF -8 4"NPT BA 2.5GAL 3KPSI OS HF -6 4"NPT BA 2.5GAL 5KPSI WS -4 1.25" NPT BA 1GAL 5KPSI OS -8 1.75"NPT BA 1PT 3KPSI OS -28 .76"SAE BA 1PT 3KPSI OS -8 .5GAL 3KPSI WS -4 1.5GAL 3KPSI OS -1 4BLT BA 2.25"NPT BA 1GAL 3KPSI WS -6 1.5GAL 3KPSI OS HF -1 4"NPT BA 2. Illinois USA .25" NPT BA 1GAL 5KPSI OS -3 1.5"SAE BA 2.5" 4 BOLT BA 2.25"SAE BA 1GAL 3KPSI OS -3 1.75"NPT BA 1PT 3KPSI WS -8 .75"NPT BA 1PT 3KPSI WS -4 .5"SAE BA 2.25"NPT BA 1GAL 3KPSI WS -8 1.25" NPT BA 1GAL 5KPSI OS -28 1.75"NPT BA 1PT 3KPSI WS -3 .75"SAE BA 1QT 3KPSI OS -3 .5GAL 5KPSI WS -1 1.25"NPT BA 1GAL 3KPSI OS -3 1.75"NPT BA 1PT 3KPSI WS -28 .5GAL 3KPSI OS -4 2"NPT BA 2.5GAL 3KPSI OS HF -28 4"NPT BA 2.5GAL 3KPSI WS -28 1.5GAL 3KPSI WS -8 2"NPT BA 2.25"NPT BA 1GAL 3KPSI WS -3 1.5GAL 3KPSI OS -1 2"NPT BA 2.5"SAE BA 2.5" 4 BOLT BA 2.75"NPT BA 1QT 3KPSI WS -8 .25"NPT BA 1GAL 3KPSI OS -28 1.25" SAE BA 1GAL 5KPSI WS -4 1.5"SAE BA 2.25" NPT BA 1GAL 5KPSI OS -4 1.5" 4 BOLT 194 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.75"SAE BA 1PT 3KPSI OS -6 .5GAL 3KPSI OS -1 1.75"NPT BA 1PT 3KPSI OS -4 .25"SAE BA 1GAL 3KPSI OS -4 1.25" NPT BA 1GAL 5KPSI WS -6 1.75"SAE BA 1PT 3KPSI OS -28 .25"SAE BA 1GAL 3KPSI WS -4 1.5GAL 3KPSI OS -3 2"NPT BA 2.5GAL 3KPSI OS -28 1.75"NPT BA 1PT 3KPSI OS -8 .25"SAE BA 1GAL 3KPSI OS -1 1.5GAL 5KPSI WS -6 1.25" NPT BA 2.5GAL 3KPSI WS -1 1.5GAL 3KPSI WS HF -6 4"NPT BA 2.5" 4 BOLT BA 2.5GAL 5KPSI OS -4 1.Catalog HY10-1630/US Model Number to EPN Crossover Model Number BA001B3T01A1 BA001B3T01W1 BA001B3T03A1 BA001B3T04A1 BA001B3T04W1 BA001B3T06A1 BA001B3T08A1 BA001B3T28A1 BA001B3U01A1 BA001B3U01W1 BA001B3U03A1 BA001B3U03W1 BA001B3U04A1 BA001B3U04W1 BA001B3U06A1 BA001B3U06W1 BA001B3U08A1 BA001B3U08W1 BA001B3U28A1 BA001B3U28W1 BA002B3T01A1 BA002B3T01W1 BA002B3T03A1 BA002B3T04A1 BA002B3T04W1 BA002B3T06A1 BA002B3T08A1 BA002B3T28A1 BA002B3U01A1 BA002B3U01W1 BA002B3U03A1 BA002B3U03W1 BA002B3U04A1 BA002B3U04W1 BA002B3U06A1 BA002B3U06W1 BA002B3U08A1 BA002B3U08W1 BA002B3U28A1 BA002B3U28W1 BA005B3T01A1 BA005B3U01A1 BA005B3U01W1 BA005B3U03A1 BA005B3U03W1 BA005B3U04A1 BA005B3U04W1 BA005B3U06A1 BA005B3U06W1 BA005B3U08A1 BA005B3U08W1 BA005B3U28A1 BA005B3U28W1 BA01B3F01A1 BA01B3T01A1 BA01B3T01W1 BA01B3T03A1 BA01B3T04A1 BA01B3T04W1 BA01B3T06A1 BA01B3T08A1 BA01B3T28A1 BA01B3T28W1 BA01B3U01A1 BA01B3U01W1 BA01B3U03A1 BA01B3U03W1 Greer Accumulators Model Number Conversion Table Model Number BA01B3U04A1 BA01B3U04W1 BA01B3U06A1 BA01B3U06W1 BA01B3U08A1 BA01B3U08W1 BA01B3U28A1 BA01B3U28W1 BA01B5T01A1 BA01B5T01W1 BA01B5T04A1 BA01B5T04W1 BA01B5U01A1 BA01B5U01W1 BA01B5U03A1 BA01B5U03W1 BA01B5U04A1 BA01B5U04W1 BA01B5U06A1 BA01B5U06W1 BA01B5U08A1 BA01B5U08W1 BA01B5U28A1 BA01B5U28W1 BA02B3F01A1 BA02B3H01A1 BA02B3H01W1 BA02B3H03A1 BA02B3H03W1 BA02B3H04A1 BA02B3H04W1 BA02B3H06A1 BA02B3H06W1 BA02B3H08A1 BA02B3H08W1 BA02B3H28A1 BA02B3H28W1 BA02B3T01A1 BA02B3T01W1 BA02B3T03A1 BA02B3T04A1 BA02B3T04W1 BA02B3T06A1 BA02B3T08A1 BA02B3T08W1 BA02B3T28A1 BA02B3T28W1 BA02B3U01A1 BA02B3U01W1 BA02B3U03A1 BA02B3U03W1 BA02B3U04A1 BA02B3U04W1 BA02B3U06A1 BA02B3U06W1 BA02B3U08A1 BA02B3U08W1 BA02B3U28A1 BA02B3U28W1 BA02B5F01A1 BA02B5F01W1 BA02B5F03A1 BA02B5F03W1 BA02B5F04A1 BA02B5F04W1 BA02B5F06A1 BA02B5F06W1 EPN 851540 855100 851541 851542 855103 851543 851544 851546 810070 810393 810072 810395 810073 810396 810074 810397 810075 810398 810078 810401 851550 855110 851551 851552 855113 851553 851554 851556 800575 800019 800577 800592 800578 800593 800580 800595 800581 800597 800584 800598 851560 800970 813290 800972 813292 800973 813293 800974 813294 800979 813295 800978 813298 851330 841720 851230 841722 841726 851233 841724 841725 841723 851236 800001 800885 813132 800887 Description BA 1PT 3KPSI OS -1 .5GAL 3KPSI OS HF -8 4"NPT BA 2.75"SAE BA 1QT 3KPSI OS -1 .75"NPT BA 1QT 3KPSI OS -28 .75"NPT BA 1QT 3KPSI WS -28 .25"NPT EPN 813133 800888 813134 800889 813135 800890 813138 800893 851130 855330 851133 855333 842320 842330 842321 842331 842322 842332 842323 842336 842324 842334 842325 842335 857700 813620 813310 813622 813312 813623 813313 813624 813314 813625 813315 813628 813318 849760 855120 849761 849762 855123 849763 849764 855125 849768 855126 800730 810869 800732 810871 800733 810872 800734 810873 800735 810874 800738 810877 863040 863050 863041 863051 863042 863052 863043 863053 Description BA 1GAL 3KPSI OS -4 1.5"SAE BA 2.75"NPT BA 1PT 3KPSI WS -1 .5" 4 BOLT BA 2.5"SAE BA 2.75"SAE BA 1PT 3KPSI WS -4 .5"SAE BA 2.75"SAE BA 1QT 3KPSI OS -28 .5GAL 3KPSI WS -4 2"NPT BA 2.75"NPT BA 1PT 3KPSI OS -3 .5GAL 5KPSI OS -1 1.75"NPT BA 1QT 3KPSI WS -1 .25" NPT BA 1GAL 5KPSI WS -1 1.75"SAE BA 1PT 3KPSI OS -3 .25" SAE BA 1GAL 5KPSI OS -4 1.75"SAE BA 1QT 3KPSI WS -4 .25"NPT BA 1GAL 3KPSI OS -8 1.5GAL 3KPSI OS -6 1.25"SAE BA 1GAL 3KPSI WS -1 1. 5" 4 BOLT BA 5GAL 5KPSI OS -3 1.5GAL 5KPSI OS TOPRPR -4 1.5GAL 3KPSI OS TOPRPR -6 1.5" 4 BOLT BA 5GAL 5KPSI OS -1 1.5GAL 3KPSI OS TOPRPR -28 1.5" 4 BOLT BA 5GAL 5KPSI OS -4 1.5GAL 5KPSI OS TOPRPR -28 1.5GAL 5KPSI OS TOPRPR -28 2" 4 BOLT BA 2.5GAL 3KPSI OS TOPRPR -1 2"NPT BA 2.5GAL 5KPSI WS -3 2" NPT BA 2.5" SAE BA 2.5GAL 5KPSI WS TOPRPR -8 2" 4 BOLT BA 2.5GAL 5KPSI WS -8 2" NPT BA 2.5GAL 5KPSI OS TOPRPR -4 2" NPT BA 2.5" SAE EPN 858512 858522 858513 858523 858514 858524 858516 858526 858490 858500 858491 858501 858492 858502 858493 858503 858494 858504 858496 858506 800650 810880 800652 810882 800653 810883 800655 810884 800657 810885 800661 810888 849392 850630 849391 849390 850633 800381 849394 849396 800761 800820 800763 800822 800764 800823 800766 800824 800767 800825 800770 800828 863100 863110 863101 863111 863102 863112 863103 863113 863104 863114 863106 863116 863080 863090 863081 Description BA 2.5GAL 5KPSI OS TOPRPR -8 1.5" SAE BA 2.5"SAE BA 2.5" 4 BOLT BA 2.5GAL 3KPSI WS TOPRPR -28 2"NPT BA 2.5GAL 5KPSI OS TOPRPR -28 2" NPT BA 2.5" 4 BOLT BA 5GAL 5KPSI OS -28 1.Catalog HY10-1630/US Model Number to EPN Crossover Model Number BA02B5F08A1 BA02B5F08W1 BA02B5F28A1 BA02B5F28W1 BA02B5T01A1 BA02B5T01W1 BA02B5T03A1 BA02B5T03W1 BA02B5T04A1 BA02B5T04W1 BA02B5T06A1 BA02B5T06W1 BA02B5T08A1 BA02B5T08W1 BA02B5T28A1 BA02B5T28W1 BA02B5U01A1 BA02B5U01W1 BA02B5U03A1 BA02B5U03W1 BA02B5U04A1 BA02B5U04W1 BA02B5U06A1 BA02B5U06W1 BA02B5U08A1 BA02B5U08W1 BA02B5U28A1 BA02B5U28W1 BA02T3F01A1 BA02T3F04A1 BA02T3F28A1 BA02T3T01A1 BA02T3T01W1 BA02T3T03A1 BA02T3T04A1 BA02T3T04W1 BA02T3T06A1 BA02T3T08A1 BA02T3T28A1 BA02T3U01A1 BA02T3U01W1 BA02T3U03A1 BA02T3U03W1 BA02T3U04A1 BA02T3U04W1 BA02T3U06A1 BA02T3U06W1 BA02T3U08A1 BA02T3U08W1 BA02T3U28A1 BA02T3U28W1 BA02T5F01A1 BA02T5F01W1 BA02T5F03A1 BA02T5F03W1 BA02T5F04A1 BA02T5F04W1 BA02T5F06A1 BA02T5F06W1 BA02T5F08A1 BA02T5F08W1 BA02T5F28A1 BA02T5F28W1 BA02T5T01A1 BA02T5T01W1 BA02T5T03A1 BA02T5T03W1 Greer Accumulators Model Number Conversion Table Model Number BA02T5T04A1 BA02T5T04W1 BA02T5T06A1 BA02T5T06W1 BA02T5T08A1 BA02T5T08W1 BA02T5T28A1 BA02T5T28W1 BA02T5U01A1 BA02T5U01W1 BA02T5U03A1 BA02T5U03W1 BA02T5U04A1 BA02T5U04W1 BA02T5U06A1 BA02T5U06W1 BA02T5U08A1 BA02T5U08W1 BA02T5U28A1 BA02T5U28W1 BA05B3H01A1 BA05B3H01W1 BA05B3H03A1 BA05B3H03W1 BA05B3H04A1 BA05B3H04W1 BA05B3H06A1 BA05B3H06W1 BA05B3H08A1 BA05B3H08W1 BA05B3H28A1 BA05B3H28W1 BA05B3T01A1 BA05B3T01W1 BA05B3T03A1 BA05B3T04A1 BA05B3T04W1 BA05B3T06A1 BA05B3T08A1 BA05B3T28A1 BA05B3U01A1 BA05B3U01W1 BA05B3U03A1 BA05B3U03W1 BA05B3U04A1 BA05B3U04W1 BA05B3U06A1 BA05B3U06W1 BA05B3U08A1 BA05B3U08W1 BA05B3U28A1 BA05B3U28W1 BA05B5F01A1 BA05B5F01W1 BA05B5F03A1 BA05B5F03W1 BA05B5F04A1 BA05B5F04W1 BA05B5F06A1 BA05B5F06W1 BA05B5F08A1 BA05B5F08W1 BA05B5F28A1 BA05B5F28W1 BA05B5T01A1 BA05B5T01W1 BA05B5T03A1 EPN 863044 863054 863046 863056 863020 863030 863021 863031 863022 863032 863023 863033 863024 863034 863026 863036 863000 863010 863001 863011 863002 863012 863003 863013 863004 863014 863006 863016 853710 853712 853715 851420 855150 851421 851422 855153 851423 851424 851426 845370 845410 845372 845412 845373 845413 845376 845416 845374 845414 845375 845415 858530 858540 858531 858541 858532 858542 858533 858543 858534 858544 858536 858546 858510 858520 858511 858521 Description BA 2.5" 4 BOLT BA 2.5GAL 3KPSI WS TOPRPR -3 2"NPT BA 2.5GAL 5KPSI OS -3 1.5GAL 5KPSI WS -6 2" NPT BA 2.5" SAE BA 2.5" SAE BA 2.5GAL 3KPSI OS TOPRPR -28 2"NPT BA 2.5" SAE BA 2.5" 4 BOLT BA 5GAL 5KPSI OS -8 1.5GAL 5KPSI WS TOPRPR -4 2" 4 BOLT BA 2.5" SAE BA 2.5GAL 5KPSI WS TOPRPR -4 2" NPT BA 2.5GAL 5KPSI WS TOPRPR -28 1.5" SAE BA 2.5GAL 3KPSI OS TOPRPR -8 2"NPT BA 2.5GAL 5KPSI OS TOPRPR -3 1.5GAL 5KPSI OS TOPRPR -6 1.5" SAE BA 2.5GAL 5KPSI WS TOPRPR -8 1.5" SAE BA 2.5GAL 5KPSI OS -28 2" NPT BA 2.5GAL 5KPSI WS TOPRPR -28 2" 4 BOLT BA 2.5GAL 5KPSI OS -6 1.5GAL 5KPSI WS TOPRPR -6 1.5" SAE BA 2.5" SAE BA 2.5GAL 5KPSI WS -4 2" NPT BA 2.5" 4 BOLT BA 2.5" SAE BA 2.5GAL 3KPSI OS TOPRPR -8 1.5GAL 3KPSI OS TOPRPR -3 2"NPT BA 2.5GAL 3KPSI OS TOPRPR -3 1.5GAL 3KPSI OS TOPRPR -28 4BLT BA 2.5GAL 3KPSI WS TOPRPR -1 1.5GAL 5KPSI OS TOPRPR -1 2" 4 BOLT BA 2.5GAL 5KPSI WS -1 2" NPT BA 2.5GAL 5KPSI WS -3 1.5"SAE BA 5GAL 3KPSI OS -6 1.5"SAE BA 5GAL 3KPSI WS -4 1.5GAL 3KPSI WS TOPRPR -4 2"NPT BA 2.5" 4 BOLT BA 5GAL 5KPSI WS -8 1.5" SAE BA 2.5GAL 3KPSI WS TOPRPR -8 2"NPT BA 2.5" SAE BA 2.5GAL 3KPSI OS TOPRPR -6 2"NPT BA 2.5GAL 5KPSI WS TOPRPR -3 2" NPT BA 2.5GAL 5KPSI OS TOPRPR -1 1.5GAL 5KPSI OS -8 2" NPT BA 2.5" 4 BOLT BA 5GAL 5KPSI WS -4 1.5GAL 3KPSI OS TOPRPR -4 4BLT BA 2.5GAL 5KPSI WS -1 1.5GAL 5KPSI OS -28 1.5GAL 5KPSI OS TOPRPR -3 2" 4 BOLT BA 2.5"SAE BA 2.5GAL 5KPSI OS -6 2" NPT BA 2.5GAL 5KPSI OS -8 1.5GAL 5KPSI OS TOPRPR -6 2" 4 BOLT BA 2.5GAL 5KPSI WS TOPRPR -28 2" NPT BA 5GAL 3KPSI OS HF -1 4"NPT BA 5GAL 3KPSI WS HF -1 4"NPT BA 5GAL 3KPSI OS HF -3 4"NPT BA 5GAL 3KPSI WS HF -3 4"NPT BA 5GAL 3KPSI OS HF -4 4"NPT BA 5GAL 3KPSI WS HF -4 4"NPT BA 5GAL 3KPSI OS HF -6 4"NPT BA 5GAL 3KPSI WS HF -6 4"NPT BA 5GAL 3KPSI OS HF -8 4"NPT BA 5GAL 3KPSI WS HF -8 4"NPT BA 5GAL 3KPSI OS HF -28 4"NPT BA 5GAL 3KPSI WS HF -28 4"NPT BA 5GAL 3KPSI OS -1 1.5" 4 BOLT BA 5GAL 5KPSI OS -6 1.5" 4 BOLT BA 2.5GAL 3KPSI OS TOPRPR -1 4BLT BA 2.5"SAE BA 2.5GAL 5KPSI WS TOPRPR -4 1.5GAL 5KPSI OS TOPRPR -8 2" NPT BA 2.5GAL 5KPSI WS -6 1.5GAL 5KPSI WS TOPRPR -1 1.5GAL 5KPSI OS -1 2" NPT BA 2.5" SAE BA 2.5" 4 BOLT BA 5GAL 5KPSI WS -1 1.5GAL 5KPSI WS -8 1.5"SAE BA 5GAL 3KPSI OS -4 1.5" SAE BA 5GAL 5KPSI OS -3 1.5" SAE BA 2.5GAL 5KPSI WS TOPRPR -6 2" 4 BOLT BA 2.5GAL 5KPSI WS -28 1.5"SAE BA 5GAL 3KPSI OS -1 2"NPT BA 5GAL 3KPSI WS -1 2"NPT BA 5GAL 3KPSI OS -3 2"NPT BA 5GAL 3KPSI WS -3 2"NPT BA 5GAL 3KPSI OS -4 2"NPT BA 5GAL 3KPSI WS -4 2"NPT BA 5GAL 3KPSI OS -6 2"NPT BA 5GAL 3KPSI WS -6 2"NPT BA 5GAL 3KPSI OS -8 2"NPT BA 5GAL 3KPSI WS -8 2"NPT BA 5GAL 3KPSI OS -28 2"NPT BA 5GAL 3KPSI WS -28 2"NPT BA 5GAL 5KPSI OS -1 1.5" 4 BOLT BA 5GAL 5KPSI WS -28 1.5" SAE BA 2.5" SAE BA 2.5"SAE BA 5GAL 3KPSI OS -3 1.5GAL 5KPSI WS TOPRPR -1 2" 4 BOLT BA 2.5GAL 5KPSI WS TOPRPR -8 2" NPT BA 2.5GAL 5KPSI WS TOPRPR -3 2" 4 BOLT BA 2.5GAL 3KPSI OS TOPRPR -4 2"NPT BA 2.5GAL 5KPSI OS -4 2" NPT BA 2.5GAL 5KPSI OS TOPRPR -4 2" 4 BOLT BA 2.5GAL 3KPSI WS TOPRPR -6 2"NPT BA 2.5GAL 5KPSI WS -28 1.5GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 2.5"SAE BA 2.5GAL 5KPSI OS TOPRPR -6 2" NPT BA 2.5GAL 5KPSI WS TOPRPR -1 2" NPT BA 2.5" 4 BOLT BA 5GAL 5KPSI WS -3 1.5"SAE BA 5GAL 3KPSI OS -8 1.5GAL 5KPSI WS -8 1.5" SAE BA 2.5"SAE BA 2.5GAL 5KPSI WS TOPRPR -6 2" NPT BA 2.5" SAE BA 5GAL 5KPSI WS -1 1.5" SAE BA 2.5"SAE BA 2.5GAL 3KPSI OS TOPRPR -1 1.5" SAE 195 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5" 4 BOLT BA 5GAL 5KPSI WS -6 1.5" SAE BA 2.5GAL 5KPSI WS -4 1.5" SAE BA 2.5"SAE BA 5GAL 3KPSI OS -28 1.5" SAE BA 2.5GAL 5KPSI WS -28 2" NPT BA 2.5GAL 5KPSI WS TOPRPR -3 1.5GAL 3KPSI WS TOPRPR -1 2"NPT BA 2.5GAL 5KPSI OS TOPRPR -3 2" NPT BA 2.5GAL 5KPSI OS -8 1. Illinois USA .5GAL 5KPSI OS -4 1.5GAL 5KPSI OS -3 2" NPT BA 2.5GAL 3KPSI WS TOPRPR -4 1.5GAL 5KPSI OS -1 1.5"SAE BA 2.5"SAE BA 5GAL 3KPSI WS -1 1.5GAL 5KPSI OS TOPRPR -8 2" 4 BOLT BA 2.5GAL 5KPSI OS -28 1.5GAL 5KPSI OS TOPRPR -1 2" NPT BA 2. 5"SAE BA 10GAL 3KPSI OS -3 1.5"SAE BA 5GAL 3KPSI WS TOPRPR -4 1.5"SAE BA 10GAL 3KPSI WS -1 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -4 1. Illinois USA .Catalog HY10-1630/US Model Number to EPN Crossover Model Number BA05B5T03W1 BA05B5T04A1 BA05B5T04W1 BA05B5T06A1 BA05B5T06W1 BA05B5T08A1 BA05B5T08W1 BA05B5T28A1 BA05B5T28W1 BA05B5U01A1 BA05B5U01W1 BA05B5U03A1 BA05B5U03W1 BA05B5U04A1 BA05B5U04W1 BA05B5U06A1 BA05B5U06W1 BA05B5U08A1 BA05B5U08W1 BA05B5U28A1 BA05B5U28W1 BA05T3F01A1 BA05T3F04A1 BA05T3T01A1 BA05T3T01W1 BA05T3T03A1 BA05T3T04A1 BA05T3T04W1 BA05T3T06A1 BA05T3T08A1 BA05T3T28A1 BA05T3U01A1 BA05T3U01W1 BA05T3U03A1 BA05T3U03W1 BA05T3U04A1 BA05T3U04W1 BA05T3U06A1 BA05T3U06W1 BA05T3U08A1 BA05T3U08W1 BA05T3U28A1 BA05T3U28W1 BA05T5F01A1 BA05T5F01W1 BA05T5F03A1 BA05T5F03W1 BA05T5F04A1 BA05T5F04W1 BA05T5F06A1 BA05T5F06W1 BA05T5F08A1 BA05T5F08W1 BA05T5F28A1 BA05T5F28W1 BA05T5T01A1 BA05T5T01W1 BA05T5T03A1 BA05T5T03W1 BA05T5T04A1 BA05T5T04W1 BA05T5T06A1 BA05T5T06W1 BA05T5T08A1 BA05T5T08W1 BA05T5T28A1 BA05T5T28W1 Greer Accumulators Model Number Conversion Table Model Number BA05T5U01A1 BA05T5U01W1 BA05T5U03A1 BA05T5U03W1 BA05T5U04A1 BA05T5U04W1 BA05T5U06A1 BA05T5U06W1 BA05T5U08A1 BA05T5U08W1 BA05T5U28A1 BA05T5U28W1 BA06B3F01A1 BA10B3F01A1 BA10B3F04A1 BA10B3F28A1 BA10B3H01A1 BA10B3H01W1 BA10B3H03A1 BA10B3H03W1 BA10B3H04A1 BA10B3H04W1 BA10B3H06A1 BA10B3H06W1 BA10B3H08A1 BA10B3H08W1 BA10B3H28A1 BA10B3H28W1 BA10B3T01A1 BA10B3T01W1 BA10B3T03A1 BA10B3T04A1 BA10B3T04W1 BA10B3T06A1 BA10B3T08A1 BA10B3T28A1 BA10B3T28W1 BA10B3U01A1 BA10B3U01W1 BA10B3U03A1 BA10B3U03W1 BA10B3U04A1 BA10B3U04W1 BA10B3U06A1 BA10B3U06W1 BA10B3U08A1 BA10B3U08W1 BA10B3U28A1 BA10B3U28W1 BA10B5F01A1 BA10B5F01W1 BA10B5F03A1 BA10B5F03W1 BA10B5F04A1 BA10B5F04W1 BA10B5F06A1 BA10B5F06W1 BA10B5F08A1 BA10B5F08W1 BA10B5F28A1 BA10B5F28W1 BA10B5T01A1 BA10B5T01W1 BA10B5T03A1 BA10B5T03W1 BA10B5T04A1 BA10B5T04W1 EPN 863091 863082 863092 863083 863093 863084 863094 863086 863096 863060 863070 863061 863071 863062 863072 863063 863073 863064 863074 863066 863076 853720 853723 851430 855160 851431 851432 855163 851433 851434 851436 845380 845420 845382 845422 845383 845423 845386 845426 845384 845424 845385 845425 858590 858600 858591 858601 858592 858602 858593 858603 858594 858604 858596 858606 858570 858580 858571 858581 858572 858582 858573 858583 858574 858584 858576 858586 Description BA 5GAL 5KPSI WS -3 1.5"SAE BA 10GAL 3KPSI WS -28 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -8 1.5" SAE BA 10GAL 5KPSI OS -4 1.5" 4 BOLT BA 10GAL 5KPSI OS -8 1.5"SAE BA 5GAL 3KPSI WS TOPRPR -1 1.5" 4 BOLT BA 10GAL 5KPSI OS -3 1.5"SAE BA 10GAL 3KPSI OS -28 1.5" SAE BA 5GAL 5KPSI OS -4 1.5" SAE BA 5GAL 5KPSI OS -6 1.5" 4 BOLT BA 10GAL 5KPSI WS -6 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -28 1.5" 4 BOLT BA 10GAL 5KPSI OS -28 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -4 1.5"SAE BA 10GAL 3KPSI OS -4 1.5" 4 BOLT BA 10GAL 5KPSI WS -4 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -6 1.5"SAE BA 10GAL 3KPSI OS -1 2"NPT BA 10GAL 3KPSI WS -1 2"NPT BA 10GAL 3KPSI OS -3 2"NPT BA 10GAL 3KPSI WS -3 2"NPT BA 10GAL 3KPSI OS -4 2"NPT BA 10GAL 3KPSI WS -4 2"NPT BA 10GAL 3KPSI OS -6 2"NPT BA 10GAL 3KPSI WS -6 2"NPT BA 10GAL 3KPSI OS -8 2"NPT BA 10GAL 3KPSI WS -8 2"NPT BA 10GAL 3KPSI OS -28 2"NPT BA 10GAL 3KPSI WS -28 2"NPT BA 10GAL 5KPSI OS -1 1.5" SAE BA 5GAL 5KPSI WS -6 1.5" SAE BA 5GAL 5KPSI OS -1 2" NPT BA 5GAL 5KPSI WS -1 2" NPT BA 5GAL 5KPSI OS -3 2" NPT BA 5GAL 5KPSI WS -3 2" NPT BA 5GAL 5KPSI OS -4 2" NPT BA 5GAL 5KPSI WS -4 2" NPT BA 5GAL 5KPSI OS -6 2" NPT BA 5GAL 5KPSI WS -6 2" NPT BA 5GAL 5KPSI OS -8 2" NPT BA 5GAL 5KPSI WS -8 2" NPT BA 5GAL 5KPSI OS -28 2" NPT BA 5GAL 5KPSI WS -28 2" NPT BA 5GAL 3KPSI OS TOPRPR -1 4BLT BA 5GAL 3KPSI OS TOPRPR -4 4BLT BA 5GAL 3KPSI OS TOPRPR -1 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -6 1.5" SAE BA 10GAL 5KPSI WS -3 1.5" SAE BA 10GAL 5KPSI WS -1 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -1 1.5" SAE BA 10GAL 5KPSI OS -3 1.5"SAE BA 10GAL 3KPSI OS -8 1.5" SAE BA 5GAL 5KPSI OS -8 1.5" 4 BOLT BA 10GAL 5KPSI OS -4 1.5" 4 BOLT BA 10GAL 5KPSI WS -1 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -28 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -8 1.5" SAE BA 5GAL 5KPSI WS -4 1.5" SAE BA 5GAL 5KPSI OS -28 1.5" 4 BOLT BA 10GAL 5KPSI OS -1 1.5" 4 BOLT BA 10GAL 5KPSI OS -6 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 10GAL 3KPSI OS -6 1.5" SAE EPN 858550 858560 858551 858561 858552 858562 858553 858563 858554 858564 858556 858566 851335 854570 854572 854576 800665 813650 800667 813652 800668 813653 800670 813654 800672 813655 800676 813658 850670 855130 850671 850672 855133 850673 850674 850676 855136 800776 800834 800778 800836 800779 800837 800781 800838 800782 800839 800785 800842 863160 863170 863161 863171 863162 863172 863163 863173 863164 863174 863166 863176 863140 863150 863141 863151 863142 863152 Description BA 5GAL 5KPSI OS TOPRPR -1 2" NPT BA 5GAL 5KPSI WS TOPRPR -1 2" NPT BA 5GAL 5KPSI OS TOPRPR -3 2" NPT BA 5GAL 5KPSI WS TOPRPR -3 2" NPT BA 5GAL 5KPSI OS TOPRPR -4 2" NPT BA 5GAL 5KPSI WS TOPRPR -4 2" NPT BA 5GAL 5KPSI OS TOPRPR -6 2" NPT BA 5GAL 5KPSI WS TOPRPR -6 2" NPT BA 5GAL 5KPSI OS TOPRPR -8 2" NPT BA 5GAL 5KPSI WS TOPRPR -8 2" NPT BA 5GAL 5KPSI OS TOPRPR -28 2" NPT BA 5GAL 5KPSI WS TOPRPR -28 2" NPT BA 5GAL 3KPSI OS -1 4BLT BA 10GAL 3KPSI OS -1 4BLT BA 10GAL 3KPSI OS -4 4BLT BA 10GAL 3KPSI OS -28 4BLT BA 10GAL 3KPSI OS HF -1 4"NPT BA 10GAL 3KPSI WS HF -1 4"NPT BA 10GAL 3KPSI OS HF -3 4"NPT BA 10GAL 3KPSI WS HF -3 4"NPT BA 10GAL 3KPSI OS HF -4 4"NPT BA 10GAL 3KPSI WS HF -4 4"NPT BA 10GAL 3KPSI OS HF -6 4"NPT BA 10GAL 3KPSI WS HF -6 4"NPT BA 10GAL 3KPSI OS HF -8 4"NPT BA 10GAL 3KPSI WS HF -8 4"NPT BA 10GAL 3KPSI OS HF -28 4"NPT BA 10GAL 3KPSI WS HF -28 4"NPT BA 10GAL 3KPSI OS -1 1.5" SAE BA 5GAL 5KPSI WS -28 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -3 1.5" 4 BOLT BA 10GAL 5KPSI WS -28 1.5" SAE BA 10GAL 5KPSI WS -4 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -6 1.5" 4 BOLT BA 10GAL 5KPSI WS -3 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -3 1.5"SAE BA 10GAL 3KPSI WS -4 1.5" SAE BA 5GAL 5KPSI WS TOPRPR -3 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -28 1.5" SAE BA 5GAL 5KPSI OS TOPRPR -8 1.5"SAE BA 5GAL 3KPSI OS TOPRPR -1 2"NPT BA 5GAL 3KPSI WS TOPRPR -1 2"NPT BA 5GAL 3KPSI OS TOPRPR -3 2"NPT BA 5GAL 3KPSI WS TOPRPR -3 2"NPT BA 5GAL 3KPSI OS TOPRPR -4 2"NPT BA 5GAL 3KPSI WS TOPRPR -4 2"NPT BA 5GAL 3KPSI OS TOPRPR -6 2"NPT BA 5GAL 3KPSI WS TOPRPR -6 2"NPT BA 5GAL 3KPSI OS TOPRPR -8 2"NPT BA 5GAL 3KPSI WS TOPRPR -8 2"NPT BA 5GAL 3KPSI OS TOPRPR -28 2"NPT BA 5GAL 3KPSI WS TOPRPR -28 2"NPT BA 5GAL 5KPSI OS TOPRPR -1 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -1 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -3 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -3 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -4 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -4 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -6 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -6 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -8 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -8 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -28 2" 4 BOLT BA 5GAL 5KPSI WS TOPRPR -28 2" 4 BOLT BA 5GAL 5KPSI OS TOPRPR -1 1.5" SAE 196 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5" SAE BA 5GAL 5KPSI WS -8 1.5" 4 BOLT BA 10GAL 5KPSI WS -8 1. 5" SAE BA 10GAL 5KPSI WS TOPRPR -8 1.5" SAE BA 10GAL 5KPSI WS TOPRPR -1 1.5" SAE BA 10GAL 5KPSI WS TOPRPR -6 1.Catalog HY10-1630/US Model Number to EPN Crossover Model Number BA10B5T06A1 BA10B5T06W1 BA10B5T08A1 BA10B5T08W1 BA10B5T28A1 BA10B5T28W1 BA10B5U01A1 BA10B5U01W1 BA10B5U03A1 BA10B5U03W1 BA10B5U04A1 BA10B5U04W1 BA10B5U06A1 BA10B5U06W1 BA10B5U08A1 BA10B5U08W1 BA10B5U28A1 BA10B5U28W1 BA10T3F01A1 BA10T3F08A1 BA10T3T01A1 BA10T3T01W1 BA10T3T03A1 BA10T3T04A1 BA10T3T04W1 BA10T3T06A1 BA10T3T08A1 BA10T3T28A1 BA10T3U01A1 BA10T3U01W1 BA10T3U03A1 BA10T3U03W1 BA10T3U04A1 BA10T3U04W1 BA10T3U06A1 BA10T3U06W1 BA10T3U08A1 BA10T3U08W1 BA10T3U28A1 BA10T3U28W1 BA10T5F01A1 BA10T5F01W1 BA10T5F03A1 BA10T5F03W1 BA10T5F04A1 BA10T5F04W1 BA10T5F06A1 BA10T5F06W1 BA10T5F08A1 BA10T5F08W1 BA10T5F28A1 BA10T5F28W1 BA10T5T01A1 BA10T5T01W1 BA10T5T03A1 BA10T5T03W1 BA10T5T04A1 BA10T5T04W1 BA10T5T06A1 BA10T5T06W1 BA10T5T08A1 BA10T5T08W1 BA10T5T28A1 BA10T5T28W1 BA10T5U01A1 BA10T5U01W1 BA10T5U03A1 Greer Accumulators Model Number Conversion Table Model Number BA10T5U03W1 BA10T5U04A1 BA10T5U04W1 BA10T5U06A1 BA10T5U06W1 BA10T5U08A1 BA10T5U08W1 BA10T5U28A1 BA10T5U28W1 BA11B3F01A1 BA11B3H01W1 BA11B3H03A1 BA11B3H03W1 BA11B3H04A1 BA11B3H04W1 BA11B3H06A1 BA11B3H06W1 BA11B3H08A1 BA11B3H08W1 BA11B3H28A1 BA11B3H28W1 BA11B3HT01A1 BA11B3T01A1 BA11B3T01W1 BA11B3T03A1 BA11B3T04A1 BA11B3T04W1 BA11B3T06A1 BA11B3T08A1 BA11B3T28A1 BA11B3U01A1 BA11B3U01W1 BA11B3U03A1 BA11B3U03W1 BA11B3U04A1 BA11B3U04W1 BA11B3U06A1 BA11B3U06W1 BA11B3U08A1 BA11B3U08W1 BA11B3U28A1 BA11B3U28W1 BA11T3F01A1 BA11T3T01A1 BA11T3T01W1 BA11T3T03A1 BA11T3T04A1 BA11T3T04W1 BA11T3T06A1 BA11T3T08A1 BA11T3T28A1 BA11T3U01A1 BA11T3U01W1 BA11T3U03A1 BA11T3U03W1 BA11T3U04A1 BA11T3U04W1 BA11T3U06A1 BA11T3U06W1 BA11T3U08A1 BA11T3U08W1 BA11T3U28A1 BA11T3U28W1 BA15B3F01A1 BA15B3F03A1 BA15B3F04A1 BA15B3F06A1 EPN 863143 863153 863144 863154 863146 863156 863120 863130 863121 863131 863122 863132 863123 863133 863124 863134 863126 863136 857200 857205 851590 855170 851591 851592 855173 851593 851594 851596 845390 845430 845392 845432 845393 845433 845396 845436 845394 845434 845395 845435 858650 858660 858651 858661 858652 858662 858653 858663 858654 858664 858656 858666 858630 858640 858631 858641 858632 858642 858633 858643 858634 858644 858636 858646 858610 858620 858611 Description BA 10GAL 5KPSI OS -6 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -28 1.5" SAE BA 10GAL 5KPSI OS -1 2" NPT BA 10GAL 5KPSI WS -1 2" NPT BA 10GAL 5KPSI OS -3 2" NPT BA 10GAL 5KPSI WS -3 2" NPT BA 10GAL 5KPSI OS -4 2" NPT BA 10GAL 5KPSI WS -4 2" NPT BA 10GAL 5KPSI OS -6 2" NPT BA 10GAL 5KPSI WS -6 2" NPT BA 10GAL 5KPSI OS -8 2" NPT BA 10GAL 5KPSI WS -8 2" NPT BA 10GAL 5KPSI OS -28 2" NPT BA 10GAL 5KPSI WS -28 2" NPT BA 10GAL 3KPSI OS TOPRPR -1 2" 4BLT BA 10GAL 3KPSI OS TOPRPR -8 2" 4BLT BA 10GAL 3KPSI OS TOPRPR -1 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -1 2"NPT BA 11GAL 3KPSI WS TOPRPR -1 2"NPT BA 11GAL 3KPSI OS TOPRPR -3 2"NPT BA 11GAL 3KPSI WS TOPRPR -3 2"NPT BA 11GAL 3KPSI OS TOPRPR -4 2"NPT BA 11GAL 3KPSI WS TOPRPR -4 2"NPT BA 11GAL 3KPSI OS TOPRPR -6 2"NPT BA 11GAL 3KPSI WS TOPRPR -6 2"NPT BA 11GAL 3KPSI OS TOPRPR -8 2"NPT BA 11GAL 3KPSI WS TOPRPR -8 2"NPT BA 11GAL 3KPSI OS TOPRPR -28 2"NPT BA 11GAL 3KPSI WS TOPRPR -28 2"NPT BA 15GAL 3KPSI OS -1 4BLT BA 15GAL 3KPSI OS -3 4BLT BA 15GAL 3KPSI OS -4 4BLT BA 15GAL 3KPSI OS -6 4BLT 197 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5"SAE BA 11GAL 3KPSI OS -28 1.5" SAE BA 10GAL 5KPSI WS TOPRPR -3 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -8 1.5"SAE BA 11GAL 3KPSI OS -8 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -3 1.5"SAE BA 10GAL 3KPSI OS TOPRPR -3 1.5"SAE BA 11GAL 3KPSI OS -1 2"NPT BA 11GAL 3KPSI WS -1 2"NPT BA 11GAL 3KPSI OS -3 2"NPT BA 11GAL 3KPSI WS -3 2"NPT BA 11GAL 3KPSI OS -4 2"NPT BA 11GAL 3KPSI WS -4 2"NPT BA 11GAL 3KPSI OS -6 2"NPT BA 11GAL 3KPSI WS -6 2"NPT BA 11GAL 3KPSI OS -8 2"NPT BA 11GAL 3KPSI WS -8 2"NPT BA 11GAL 3KPSI OS -28 2"NPT BA 11GAL 3KPSI WS -28 2"NPT BA 11GAL 3KPSI OS TOPRPR -1 2" 4BLT BA 11GAL 3KPSI OS TOPRPR -1 1.5"SAE BA 11GAL 3KPSI OS -4 1.5" SAE BA 10GAL 5KPSI WS TOPRPR -28 1.5"SAE BA 11GAL 3KPSI WS -4 1.5"SAE BA 10GAL 3KPSI OS TOPRPR -8 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -28 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -4 1. Illinois USA .5" SAE BA 10GAL 5KPSI OS -28 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -6 1.5"SAE BA 11GAL 3KPSI WS -1 1.5"SAE BA 10GAL 3KPSI WS TOPRPR -1 1.5"SAE BA 11GAL 3KPSI WS TOPRPR -1 1.5" SAE BA 10GAL 5KPSI WS TOPRPR -4 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -3 1.5"SAE BA 11GAL 3KPSI OS -6 1.5"SAE BA 10GAL 3KPSI WS TOPRPR -4 1.5"SAE BA 11GAL 3KPSI OS -3 1.5" SAE BA 10GAL 5KPSI WS -8 1.5" SAE BA 10GAL 5KPSI OS -8 1.5" SAE BA 10GAL 5KPSI WS -28 1.5"SAE BA 10GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -8 1.5"SAE BA 11GAL 3KPSI WS TOPRPR -4 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -6 1.5" SAE BA 10GAL 5KPSI WS -6 1.5"SAE BA 10GAL 3KPSI OS TOPRPR -1 2"NPT BA 10GAL 3KPSI WS TOPRPR -1 2"NPT BA 10GAL 3KPSI OS TOPRPR -3 2"NPT BA 10GAL 3KPSI WS TOPRPR -3 2"NPT BA 10GAL 3KPSI OS TOPRPR -4 2"NPT BA 10GAL 3KPSI WS TOPRPR -4 2"NPT BA 10GAL 3KPSI OS TOPRPR -6 2"NPT BA 10GAL 3KPSI WS TOPRPR -6 2"NPT BA 10GAL 3KPSI OS TOPRPR -8 2"NPT BA 10GAL 3KPSI WS TOPRPR -8 2"NPT BA 10GAL 3KPSI OS TOPRPR -28 2"NPT BA 10GAL 3KPSI WS TOPRPR -28 2"NPT BA 10GAL 5KPSI OS TOPRPR -1 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -1 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -3 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -3 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -4 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -4 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -6 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -6 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -8 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -8 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -28 2" 4 BOLT BA 10GAL 5KPSI WS TOPRPR -28 2" 4 BOLT BA 10GAL 5KPSI OS TOPRPR -1 1.5"SAE BA 11GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 10GAL 3KPSI OS TOPRPR -28 1.5" SAE BA 10GAL 5KPSI OS TOPRPR -1 2" NPT BA 10GAL 5KPSI WS TOPRPR -1 2" NPT BA 10GAL 5KPSI OS TOPRPR -3 2" NPT EPN 858621 858612 858622 858613 858623 858614 858624 858616 858626 857710 850820 850811 850821 850812 850822 850813 850823 850814 850824 850816 850826 850810 849900 855140 849901 849592 855143 849593 849594 849596 846940 846890 846942 846892 846943 846893 846948 846896 846944 846894 846945 846895 857720 851780 855180 851781 851782 855183 851783 851784 851786 845311 847550 845313 847552 845314 847553 845315 847556 845318 847554 845319 847555 856220 856221 856222 856223 Description BA 10GAL 5KPSI WS TOPRPR -3 2" NPT BA 10GAL 5KPSI OS TOPRPR -4 2" NPT BA 10GAL 5KPSI WS TOPRPR -4 2" NPT BA 10GAL 5KPSI OS TOPRPR -6 2" NPT BA 10GAL 5KPSI WS TOPRPR -6 2" NPT BA 10GAL 5KPSI OS TOPRPR -8 2" NPT BA 10GAL 5KPSI WS TOPRPR -8 2" NPT BA 10GAL 5KPSI OS TOPRPR -28 2" NPT BA 10GAL 5KPSI WS TOPRPR -28 2" NPT BA 11GAL 3KPSI OS -1 4BLT BA 11GAL 3KPSI WS HF -1 4"NPT BA 11GAL 3KPSI OS HF -3 4"NPT BA 11GAL 3KPSI WS HF -3 4"NPT BA 11GAL 3KPSI OS HF -4 4"NPT BA 11GAL 3KPSI WS HF -4 4"NPT BA 11GAL 3KPSI OS HF -6 4"NPT BA 11GAL 3KPSI WS HF -6 4"NPT BA 11GAL 3KPSI OS HF -8 4"NPT BA 11GAL 3KPSI WS HF -8 4"NPT BA 11GAL 3KPSI OS HF -28 4"NPT BA 11GAL 3KPSI WS HF -28 4"NPT BA 11GAL 3KPSI OS HF -1 4"NPT BA 11GAL 3KPSI OS -1 1.5"SAE BA 10GAL 3KPSI OS TOPRPR -6 1. 5" 4 BOLT BA 15GAL 5KPSI WS -3 1.5" SAE BA 15GAL 5KPSI OS -1 2" NPT BA 15GAL 5KPSI WS -1 2" NPT BA 15GAL 5KPSI OS -3 2" NPT BA 15GAL 5KPSI WS -3 2" NPT BA 15GAL 5KPSI OS -4 2" NPT BA 15GAL 5KPSI WS -4 2" NPT BA 15GAL 5KPSI OS -6 2" NPT BA 15GAL 5KPSI WS -6 2" NPT BA 15GAL 5KPSI OS -8 2" NPT EPN 863194 863186 863196 857330 852480 855190 852481 852482 855193 852483 852484 852486 845400 845440 845402 845442 845403 845443 845406 845446 845404 845444 845405 845445 858710 858720 858711 858721 858712 858722 858713 858723 858714 858724 858716 858726 858690 858700 858691 858701 858692 858702 858693 858703 858694 858704 858696 858706 858670 858680 858671 858681 858672 858682 858673 858683 858674 858684 858676 858686 835160 839170 839160 839161 839162 839163 839165 Description BA 15GAL 5KPSI WS -8 2" NPT BA 15GAL 5KPSI OS -28 2" NPT BA 15GAL 5KPSI WS -28 2" NPT BA 15GAL 3KPSI OS TOPRPR -1 2" 4BLT BA 15GAL 3KPSI OS TOPRPR -1 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -28 1.5" 4 BOLT BA 15GAL 5KPSI OS -6 1.5"SAE BA 15GAL 3KPSI WS TOPRPR -4 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -6 1.5" 4 BOLT BA 15GAL 5KPSI OS -1 1.5"SAE BA 15GAL 3KPSI OS -8 1.5" SAE BA 15GAL 5KPSI OS -3 1.5" 4 BOLT BA 15GAL 5KPSI WS -4 1.5" 4 BOLT BA 15GAL 5KPSI OS -3 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -8 1.5"SAE BA 15GAL 3KPSI OS -3 1.5"SAE BA 15GAL 3KPSI WS -4 1.5" SAE BA 15GAL 5KPSI WS -8 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -8 1.5" 4 BOLT BA 15GAL 5KPSI OS -4 1.Catalog HY10-1630/US Model Number to EPN Crossover Model Number BA15B3F08A1 BA15B3F28A1 BA15B3H01A1 BA15B3H01W1 BA15B3H03A1 BA15B3H03W1 BA15B3H04A1 BA15B3H04W1 BA15B3H06A1 BA15B3H06W1 BA15B3H08A1 BA15B3H08W1 BA15B3H28A1 BA15B3H28W1 BA15B3T01A1 BA15B3T01W1 BA15B3T03A1 BA15B3T04A1 BA15B3T04W1 BA15B3T06A1 BA15B3T08A1 BA15B3T28A1 BA15B3U01A1 BA15B3U01W1 BA15B3U03A1 BA15B3U03W1 BA15B3U04A1 BA15B3U04W1 BA15B3U06A1 BA15B3U06W1 BA15B3U08A1 BA15B3U08W1 BA15B3U28A1 BA15B3U28W1 BA15B5F01A1 BA15B5F01W1 BA15B5F03A1 BA15B5F03W1 BA15B5F04A1 BA15B5F04W1 BA15B5F06A1 BA15B5F06W1 BA15B5F08A1 BA15B5F08W1 BA15B5F28A1 BA15B5F28W1 BA15B5T01A1 BA15B5T01W1 BA15B5T03A1 BA15B5T03W1 BA15B5T04A1 BA15B5T04W1 BA15B5T06A1 BA15B5T06W1 BA15B5T08A1 BA15B5T08W1 BA15B5T28A1 BA15B5T28W1 BA15B5U01A1 BA15B5U01W1 BA15B5U03A1 BA15B5U03W1 BA15B5U04A1 BA15B5U04W1 BA15B5U06A1 BA15B5U06W1 BA15B5U08A1 Greer Accumulators Model Number Conversion Table Model Number BA15B5U08W1 BA15B5U28A1 BA15B5U28W1 BA15T3F01A1 BA15T3T01A1 BA15T3T01W1 BA15T3T03A1 BA15T3T04A1 BA15T3T04W1 BA15T3T06A1 BA15T3T08A1 BA15T3T28A1 BA15T3U01A1 BA15T3U01W1 BA15T3U03A1 BA15T3U03W1 BA15T3U04A1 BA15T3U04W1 BA15T3U06A1 BA15T3U06W1 BA15T3U08A1 BA15T3U08W1 BA15T3U28A1 BA15T3U28W1 BA15T5F01A1 BA15T5F01W1 BA15T5F03A1 BA15T5F03W1 BA15T5F04A1 BA15T5F04W1 BA15T5F06A1 BA15T5F06W1 BA15T5F08A1 BA15T5F08W1 BA15T5F28A1 BA15T5F28W1 BA15T5T01A1 BA15T5T01W1 BA15T5T03A1 BA15T5T03W1 BA15T5T04A1 BA15T5T04W1 BA15T5T06A1 BA15T5T06W1 BA15T5T08A1 BA15T5T08W1 BA15T5T28A1 BA15T5T28W1 BA15T5U01A1 BA15T5U01W1 BA15T5U03A1 BA15T5U03W1 BA15T5U04A1 BA15T5U04W1 BA15T5U06A1 BA15T5U06W1 BA15T5U08A1 BA15T5U08W1 BA15T5U28A1 BA15T5U28W1 BA25T3U01A1 BA25T3U01W1 BA25T3U03A1 BA25T3U04A1 BA25T3U06A1 BA25T3U08A1 BA25T3U28A1 EPN 856224 856225 842530 848900 842531 848901 842532 848902 842533 848903 842534 848904 842536 848906 849910 854530 849911 849912 854533 849913 849914 849916 835165 835166 839185 841711 839184 841712 839181 841715 839182 841713 839180 841714 863220 863230 863221 863231 863222 863232 863223 863233 863224 863234 863226 863236 863200 863210 863201 863211 863202 863212 863203 863213 863204 863214 863206 863216 863180 863190 863181 863191 863182 863192 863183 863193 863184 Description BA 15GAL 3KPSI OS -8 4BLT BA 15GAL 3KPSI OS -28 4BLT BA 15GAL 3KPSI OS HF -1 4"NPT BA 15GAL 3KPSI WS HF -1 4"NPT BA 15GAL 3KPSI OS HF -3 4"NPT BA 15GAL 3KPSI WS HF -3 4"NPT BA 15GAL 3KPSI OS HF -4 4"NPT BA 15GAL 3KPSI WS HF -4 4"NPT BA 15GAL 3KPSI OS HF -6 4"NPT BA 15GAL 3KPSI WS HF -6 4"NPT BA 15GAL 3KPSI OS HF -8 4"NPT BA 15GAL 3KPSI WS HF -8 4"NPT BA 15GAL 3KPSI OS HF -28 4"NPT BA 15GAL 3KPSI WS HF -28 4"NPT BA 15GAL 3KPSI OS -1 1.5" SAE BA 15GAL 5KPSI WS -1 1.5"SAE BA 15GAL 3KPSI WS TOPRPR -1 1.5"SAE BA 15GAL 3KPSI OS -6 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -4 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -4 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -6 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -1 2"NPT BA 15GAL 3KPSI WS TOPRPR -1 2"NPT BA 15GAL 3KPSI OS TOPRPR -3 2"NPT BA 15GAL 3KPSI WS TOPRPR -3 2"NPT BA 15GAL 3KPSI OS TOPRPR -4 2"NPT BA 15GAL 3KPSI WS TOPRPR -4 2"NPT BA 15GAL 3KPSI OS TOPRPR -6 2"NPT BA 15GAL 3KPSI WS TOPRPR -6 2"NPT BA 15GAL 3KPSI OS TOPRPR -8 2"NPT BA 15GAL 3KPSI WS TOPRPR -8 2"NPT BA 15GAL 3KPSI OS TOPRPR -28 2"NPT BA 15GAL 3KPSI WS TOPRPR -28 2"NPT BA 15GAL 5KPSI OS TOPRPR -1 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -1 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -3 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -3 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -4 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -4 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -6 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -6 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -8 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -8 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -28 2" 4 BOLT BA 15GAL 5KPSI WS TOPRPR -28 2" 4 BOLT BA 15GAL 5KPSI OS TOPRPR -1 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -1 2" NPT BA 15GAL 5KPSI WS TOPRPR -1 2" NPT BA 15GAL 5KPSI OS TOPRPR -3 2" NPT BA 15GAL 5KPSI WS TOPRPR -3 2" NPT BA 15GAL 5KPSI OS TOPRPR -4 2" NPT BA 15GAL 5KPSI WS TOPRPR -4 2" NPT BA 15GAL 5KPSI OS TOPRPR -6 2" NPT BA 15GAL 5KPSI WS TOPRPR -6 2" NPT BA 15GAL 5KPSI OS TOPRPR -8 2" NPT BA 15GAL 5KPSI WS TOPRPR -8 2" NPT BA 15GAL 5KPSI OS TOPRPR -28 2" NPT BA 15GAL 5KPSI WS TOPRPR -28 2" NPT BA 25GAL 3KPSI OS TOPRPR -1 3"NPT BA 25GAL 3KPSI WS TOPRPR -1 3"NPT BA 25GAL 3KPSI OS TOPRPR -3 3"NPT BA 25GAL 3KPSI OS TOPRPR -4 3"NPT BA 25GAL 3KPSI OS TOPRPR -6 3"NPT BA 25GAL 3KPSI OS TOPRPR -8 3"NPT BA 25GAL 3KPSI OS TOPRPR -28 3"NPT 198 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5" SAE BA 15GAL 5KPSI OS -8 1.5" SAE BA 15GAL 5KPSI WS -6 1.5" SAE BA 15GAL 5KPSI OS -6 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -6 1.5" 4 BOLT BA 15GAL 5KPSI WS -6 1.5" 4 BOLT BA 15GAL 5KPSI OS -8 1.5" 4 BOLT BA 15GAL 5KPSI WS -8 1.5"SAE BA 15GAL 3KPSI OS -1 2"NPT BA 15GAL 3KPSI WS -1 2"NPT BA 15GAL 3KPSI OS -3 2"NPT BA 15GAL 3KPSI WS -3 2"NPT BA 15GAL 3KPSI OS -4 2"NPT BA 15GAL 3KPSI WS -4 2"NPT BA 15GAL 3KPSI OS -6 2"NPT BA 15GAL 3KPSI WS -6 2"NPT BA 15GAL 3KPSI OS -8 2"NPT BA 15GAL 3KPSI WS -8 2"NPT BA 15GAL 3KPSI OS -28 2"NPT BA 15GAL 3KPSI WS -28 2"NPT BA 15GAL 5KPSI OS -1 1. Illinois USA .5"SAE BA 15GAL 3KPSI OS -28 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -1 1.5" SAE BA 15GAL 5KPSI WS -3 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -3 1.5"SAE BA 15GAL 3KPSI OS -4 1.5" SAE BA 15GAL 5KPSI OS -28 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -4 1.5"SAE BA 15GAL 3KPSI OS TOPRPR -3 1.5" 4 BOLT BA 15GAL 5KPSI WS -1 1.5" SAE BA 15GAL 5KPSI WS -28 1.5" 4 BOLT BA 15GAL 5KPSI OS -28 1.5" SAE BA 15GAL 5KPSI OS -4 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -8 1.5" SAE BA 15GAL 5KPSI OS TOPRPR -28 1.5" SAE BA 15GAL 5KPSI WS -4 1.5"SAE BA 15GAL 3KPSI WS -1 1.5" 4 BOLT BA 15GAL 5KPSI WS -28 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -28 1.5" SAE BA 15GAL 5KPSI WS TOPRPR -3 1. 5GAL 500PSI OS -28 3" FLG SRGKN 2.5GAL 500PSI WS -8 3" FLG SRGKN 2.5GAL 275PSI OS -4 3" FLG SRGKN 2. Illinois USA .5GAL 275PSI WS -8 3" FLG SRGKN 2.5GAL 275PSI OS -8 3" FLG SRGKN 2.5"SAE BA 10CI 3KPSI OS -4 .5GAL 500PSI -1 3" FLG FM SRGKN 2.75"NPT BA 10CI 3KPSI WS -28 .5"SAE (FIBERGLAS) KLVNT 20GAL -6 1.5"SAE (FIBERGLAS) KLVNT 20GAL -1 1"SAE KLVNT 40GAL -1 1.5"SAE KLVNT 40GAL -8 1.75"NPT BA 10CI 3KPSI OS -4 .5GAL -6 1"SAE (FIBERGLAS) KLVNT 2.75"NPT BA 10CI 3KPSI OS -3 .5"SAE KLVNT 60GAL -1 1.5GAL 500PSI OS -4 3" FLG SRGKN 2.5GAL -8 1"SAE (FIBERGLAS) KLVNT 5GAL -1 1"SAE (FIBERGLAS) KLVNT 5GAL -6 1"SAE (FIBERGLAS) KLVNT 5GAL -8 1"SAE (FIBERGLAS) KLVNT 10GAL -1 1"SAE (FIBERGLAS) KLVNT 10GAL -6 1"SAE (FIBERGLAS) KLVNT 10GAL -8 1"SAE (FIBERGLAS) KLVNT 20GAL -1 1.5"SAE KLVNT 40GAL -6 1.5"SAE KLVNT 80GAL -6 1.75"NPT BA 10CI 3KPSI WS -1 .5GAL -1 1"SAE (FIBERGLAS) KLVNT 2.5GAL 500PSI WS -28 3" FLG SRGKN 5GAL 275PSI OS -1 3" FLG SRGKN 5GAL 275PSI OS -4 3" FLG SRGKN 5GAL 275PSI OS -8 3" FLG SRGKN 5GAL 275PSI OS -28 3" FLG SRGKN 5GAL 500PSI OS -1 3" FLG SRGKN 5GAL 500PSI OS -4 3" FLG SRGKN 5GAL 500PSI OS -8 3" FLG SRGKN 5GAL 500PSI OS -28 3" FLG SRGKN 5GAL 275PSI WS -1 SLURRY 4" FLG SRGKN 5GAL 200PSI -1 3" FLG UL SRGKN 5GAL 275PSI WS -1 3" FLG SRGKN 5GAL 275PSI WS -4 3" FLG SRGKN 5GAL 275PSI WS -8 3" FLG SRGKN 5GAL 275PSI WS -28 3" FLG SRGKN 5GAL 500PSI WS -1 3" FLG SRGKN 5GAL 500PSI -1 3" FLG FM SRGKN 5GAL 500PSI WS -4 3" FLG SRGKN 5GAL 500PSI WS -8 3" FLG SRGKN 5GAL 500PSI WS -28 3" FLG SRGKN 100GAL 275PSI OS -1 4" FLG SRGKN 100GAL 275PSI OS -1 6" FLG SRGKN 100GAL 275PSI OS -1 8" FLG SRGKN 100GAL 275PSI OS -1 10" FLG SRGKN 100GAL 500PSI OS -1 4" FLG SRGKN 100GAL 500PSI OS -4 4" FLG SRGKN 100GAL 500PSI OS -8 4" FLG SRGKN 100GAL 500PSI OS -28 4" FLG SRGKN 100GAL 200PSI -1 4" FLG UL SRGKN 100GAL 275PSI WS -1 4" FLG FM SRGKN 100GAL 275PSI WS -1 6" FLG FM SRGKN 100GAL 275PSI WS -1 8" FLG FM SRGKN 100GAL 275PSI WS -1 10" FLG FM SRGKN 100GAL 400PSI -1 4" FLG FM SRGKN 100GAL 400PSI -1 6" FLG FM SRGKN 100GAL 400PSI -1 8" FLG FM SRGKN 100GAL 500PSI WS -1 4" FLG SRGKN 100GAL 500PSI WS -4 4" FLG SRGKN 100GAL 500PSI WS -8 4" FLG SRGKN 100GAL 500PSI WS -28 4" FLG SRGKN 10GAL 275PSI OS -1 3" FLG SRGKN 10GAL 275PSI OS -4 3" FLG SRGKN 10GAL 275PSI OS -8 3" FLG SRGKN 10GAL 275PSI OS -28 3" FLG SRGKN 10GAL 500PSI OS -1 3" FLG SRGKN 10GAL 500PSI OS -4 3" FLG SRGKN 10GAL 500PSI OS -8 3" FLG SRGKN 10GAL 500PSI OS -28 3" FLG SRGKN 10GAL 275PSI WS -1 SLURRY 4" FLG SRGKN 10GAL 200PSI -1 3" FLG UL SRGKN 10GAL 275PSI WS -1 3" FLG SRGKN 10GAL 275PSI WS -4 3" FLG SRGKN 10GAL 275PSI WS -8 3" FLG SRGKN 10GAL 275PSI WS -28 3" FLG SRGKN 10GAL 500PSI WS -1 3" FLG SRGKN 10GAL 500PSI -1 3" FLG FM SRGKN 10GAL 500PSI WS -4 3" FLG SRGKN 10GAL 500PSI WS -8 3" FLG SRGKN 10GAL 500PSI WS -28 3" FLG SRGKN 120GAL 275PSI OS -1 4" FLG SRGKN 120GAL 275PSI OS -1 6" FLG SRGKN 120GAL 275PSI OS -1 8" FLG SRGKN 120GAL 275PSI OS -1 10" FLG SRGKN 120GAL 500PSI OS -1 4" FLG 199 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford.5GAL 275PSI WS -1 SLURRY 4" FLG SRGKN 2.75"NPT BA 10CI 3KPSI OS -28 .5GAL 275PSI WS -1 3" FLG SRGKN 2.5"SAE BA 10CI 3KPSI OS -3 .5"SAE BA 10CI 3KPSI OS -6 .5"SAE BA 10CI 3KPSI OS -8 .5GAL 500PSI OS -1 3" FLG SRGKN 2.75"SAE BA 10CI 3KPSI OS -1 .5"SAE KLVNT 20GAL -8 1"SAE KLVNT 60GAL -8 1.75"NPT KLVNT 2.5"SAE BA 10CI 3KPSI WS -1 .5GAL 275PSI WS -28 3" FLG SRGKN 2.5"SAE (FIBERGLAS) KLVNT 20GAL -8 1.75"NPT BA 10CI 3KPSI WS -6 .75"NPT BA 10CI 3KPSI WS -8 .75"NPT BA 10CI 3KPSI OS -6 .75"NPT BA 10CI 3KPSI WS -4 .5"SAE KLVNT 20GAL -28 1"SAE SRGKN 2.75"NPT BA 10CI 3KPSI OS -8 .5GAL 275PSI OS -1 3" FLG SRGKN 2.5"SAE KLVNT 40GAL -28 1.5"SAE BA 10CI 3KPSI WS -4 .5"SAE KLVNT 80GAL -8 1.5"SAE BA 10CI 3KPSI OS -28 .5GAL 200PSI -1 3" FLG UL SRGKN 2.Catalog HY10-1630/US Model Number to EPN Crossover Model Number BA40T3U01A1 BA40T3U01W1 BA40T3U03A1 BA40T3U04A1 BA40T3U06A1 BA40T3U08A1 BA40T3U28A1 BAC10B3T01A1 BAC10B3T01W1 BAC10B3T28A1 BAC10B3TO3A1 BAC10B3TO4A1 BAC10B3TO4W1 BAC10B3TO6A1 BAC10B3TO8A1 BAC10B3U01A1 BAC10B3U01W1 BAC10B3U28A1 BAC10B3U28W1 BAC10B3UO3A1 BAC10B3UO3W1 BAC10B3UO4A1 BAC10B3UO4W1 BAC10B3UO6A1 BAC10B3UO6W1 BAC10B3UO8A1 BAC10B3UO8W1 KV02F0T01A1 KV02F0T06A1 KV02F0T08A1 KV05F0T01A1 KV05F0T06A1 KV05F0T08A1 KV10F0T01A1 KV10F0T06A1 KV10F0T08A1 KV20F0T01A1 KV20F0T06A1 KV20F0T08A1 KV20M0T01A1 KV40M0T01A1 KV60M0T01A1 KV80M0T01A1 KV40M0T06A1 KV20M0T06A1 KV60M0T06A1 KV80M0T06A1 KV20M0T08A1 KV60M0T08A1 KV80M0T08A1 KV40M0T08A1 KV40M0T281A1 KV20M0T28A1 SK02A3FA01A1 SK02A3FA04A1 SK02A3FA08A1 SK02A3FA28A1 SK02A5PA01A1 SK02A5PA04A1 SK02A5PA08A1 SK02A5PA28A1 SK02S3FB01A1 SK02W2FA01U1 SK02W3FA01A1 SK02W3FA08A1 SK02W3FA28A1 SK02W5PA01A1 Greer Accumulators Model Number Conversion Table Model Number SK02W5PA01F1 SK02W5PA04A1 SK02W5PA08A1 SK02W5PA28A1 SK05A3FA01A1 SK05A3FA04A1 SK05A3FA08A1 SK05A3FA28A1 SK05A5PA01A1 SK05A5PA04A1 SK05A5PA08A1 SK05A5PA28A1 SK05S3FB01A1 SK05W2FA01U1 SK05W3FA01A1 SK05W3FA04A1 SK05W3FA08A1 SK05W3FA28A1 SK05W5PA01A1 SK05W5PA01F1 SK05W5PA04A1 SK05W5PA08A1 SK05W5PA28A1 SK100A3FB01A1 SK100A3FC01A1 SK100A3FD01A1 SK100A3FE01A1 SK100A5PB01A1 SK100A5PB04A1 SK100A5PB08A1 SK100A5PB28A1 SK100W2FB01U1 SK100W3FB01F1 SK100W3FC01F1 SK100W3FD01F1 SK100W3FE01F1 SK100W4PB01F1 SK100W4PC01F1 SK100W4PD01F1 SK100W5PB01A1 SK100W5PB04A1 SK100W5PB08A1 SK100W5PB28A1 SK10A3FA01A1 SK10A3FA04A1 SK10A3FA08A1 SK10A3FA28A1 SK10A5PA01A1 SK10A5PA04A1 SK10A5PA08A1 SK10A5PA28A1 SK10S3FB01A1 SK10W2FA01U1 SK10W3FA01A1 SK10W3FA04A1 SK10W3FA08A1 SK10W3FA28A1 SK10W5PA01A1 SK10W5PA01F1 SK10W5PA04A1 SK10W5PA08A1 SK10W5PA28A1 SK120A3FB01A1 SK120A3FC01A1 SK120A3FD01A1 SK120A3FE01A1 SK120A5PB01A1 EPN 835161 835164 839272 839273 839275 839271 839270 851520 855090 851526 851521 851522 855093 851523 851524 800010 813220 800802 813228 800793 813222 800794 813223 800796 813224 800798 813225 857780 857783 857784 857790 857793 857794 857800 857803 857804 856940 856943 856944 800876 800877 800878 800879 812976 813026 813053 813075 805017 805043 813603 813803 813804 805018 863770 863772 863774 863775 863790 863792 863794 863795 805150 810000 800680 800685 800689 863816 Description BA 40GAL 3KPSI OS TOPRPR -1 3"NPT BA 40GAL 3KPSI WS TOPRPR -1 3"NPT BA 40GAL 3KPSI OS TOPRPR -3 3"NPT BA 40GAL 3KPSI OS TOPRPR -4 3"NPT BA 40GAL 3KPSI OS TOPRPR -6 3"NPT BA 40GAL 3KPSI OS TOPRPR -8 3"NPT BA 40GAL 3KPSI OS TOPRPR -28 3"NPT BA 10CI 3KPSI OS -1 .5"SAE KLVNT 20GAL -6 1"SAE KLVNT 60GAL -6 1.5GAL 500PSI WS -1 3" FLG EPN 863737 863818 863819 863821 863776 863778 863780 863781 863796 863798 863800 863801 805160 810015 800695 849382 800700 800703 863822 863738 863824 863826 863827 863844 863856 863862 863868 863892 863898 863904 863910 813560 859980 860030 860080 860130 860180 860230 860280 860181 860182 860184 863762 863782 863784 863786 863787 863802 863804 863806 863807 805170 810030 800710 849381 800715 800718 863830 863739 863832 863834 863835 863845 863857 863863 863869 863893 Description SRGKN 2.5GAL 275PSI OS -28 3" FLG SRGKN 2.5GAL 500PSI OS -8 3" FLG SRGKN 2.5GAL 500PSI WS -4 3" FLG SRGKN 2.5"SAE KLVNT 80GAL -1 1.75"NPT BA 10CI 3KPSI WS -3 . Catalog HY10-1630/US Model Number to EPN Crossover Model Number SK120A5PB04A1 SK120A5PB08A1 SK120A5PB28A1 SK120W2FB01U1 SK120W3FB01F1 SK120W3FC01F1 SK120W3FD01F1 SK120W3FE01F1 SK120W4PB01F1 SK120W4PC01F1 SK120W4PD01F1 SK120W5PB01A1 SK120W5PB04A1 SK120W5PB08A1 SK120W5PB28A1 SK25A3FB01A1 SK25A3FC01A1 SK25A3FD01A1 SK25A3FE01A1 SK25A5PB01A1 SK25A5PB04A1 SK25A5PB08A1 SK25A5PB28A1 SK25W2FB01U1 SK25W3FB01F1 SK25W3FC01F1 SK25W3FD01F1 SK25W3FE01F1 SK25W4PB01F1 SK25W4PC01F1 SK25W4PD01F1 SK25W53PB04A1 SK25W5PB01A1 SK25W5PB08A1 SK25W5PB28A1 SK40A3FB01A1 SK40A3FC01A1 SK40A3FD01A1 SK40A3FE01A1 SK40A5PB01A1 SK40W2FB01U1 SK40W3FB01F1 SK40W3FC01F1 SK40W3FD01F1 SK40W3FE01F1 SK40W4PB01F1 SK40W4PC01F1 SK40W4PD01F1 SK40W5PB01A1 SK40W5PB04A1 SK40W5PB04A1 SK40W5PB08A1 SK40W5PB08A1 SK40W5PB28A1 SK40W5PB28A1 SK80A3FB01A1 SK80A3FC01A1 SK80A3FD01A1 SK80A3FE01A1 SK80A5PB01A1 SK80A5PB04A1 SK80A5PB08A1 SK80A5PB28A1 SK80W2FB01U1 SK80W3FB01F1 SK80W3FC01F1 SK80W3FD01F1 Greer Accumulators Model Number Conversion Table Model Number SK80W3FE01F1 SK80W4PB01F1 SK80W4PC01F1 SK80W4PD01F1 SK80W5PB01A1 SK80W5PB04A1 SK80W5PB08A1 SK80W5PB28A1 EPN 863899 863905 863911 812760 859990 860040 860090 860140 860190 860240 860290 860191 860192 860194 863742 863840 863852 863858 863864 863888 863894 863900 863906 813460 859950 860000 860050 860100 860150 860200 860250 860152 860151 860154 860156 863841 863853 863859 863865 863889 813500 859960 860010 860060 860110 860160 860210 860260 860161 860162 863895 860164 863901 860166 863907 863843 863855 863861 863867 863891 863897 863903 863909 813540 859970 860020 860070 Description SRGKN 120GAL 500PSI OS -4 4" FLG SRGKN 120GAL 500PSI OS -8 4" FLG SRGKN 120GAL 500PSI OS -28 4" FLG SRGKN 120GAL 200PSI -1 4" FLG UL SRGKN 120GAL 275PSI WS -1 4" FLG FM SRGKN 120GAL 275PSI WS -1 6" FLG FM SRGKN 120GAL 275PSI WS -1 8" FLG FM SRGKN 120GAL 275PSI WS -1 10" FLG FM SRGKN 120GAL 400PSI -1 4" FLG FM SRGKN 120GAL 400PSI -1 6" FLG FM SRGKN 120GAL 400PSI -1 8" FLG FM SRGKN 120GAL 500PSI WS -1 4" FLG SRGKN 120GAL 500PSI WS -4 4" FLG SRGKN 120GAL 500PSI WS -8 4" FLG SRGKN 120GAL 500PSI WS -28 4" FLG SRGKN 25GAL 275PSI OS -1 4" FLG SRGKN 25GAL 275PSI OS -1 6" FLG SRGKN 25GAL 275PSI OS -1 8" FLG SRGKN 25GAL 275PSI OS -1 10" FLG SRGKN 25GAL 500PSI OS -1 4" FLG SRGKN 25GAL 500PSI OS -4 4" FLG SRGKN 25GAL 500PSI OS -8 4" FLG SRGKN 25GAL 500PSI OS -28 4" FLG SRGKN 25GAL 200PSI -1 4" FLG UL SRGKN 25GAL 275PSI WS -1 4" FLG FM SRGKN 25GAL 275PSI WS -1 6" FLG FM SRGKN 25GAL 275PSI WS -1 8" FLG FM SRGKN 25GAL 275PSI WS -1 10" FLG FM SRGKN 25GAL 400PSI -1 4" FLG FM SRGKN 25GAL 400PSI -1 6" FLG FM SRGKN 25GAL 400PSI -1 8" FLG FM SRGKN 25GAL 500PSI WS -4 4" FLG SRGKN 25GAL 500PSI WS -1 4" FLG SRGKN 25GAL 500PSI WS -8 4" FLG SRGKN 25GAL 500PSI WS -28 4" FLG SRGKN 40GAL 275PSI OS -1 4" FLG SRGKN 40GAL 275PSI OS -1 6" FLG SRGKN 40GAL 275PSI OS -1 8" FLG SRGKN 40GAL 275PSI OS -1 10" FLG SRGKN 40GAL 500PSI OS -1 4" FLG SRGKN 40GAL 200PSI -1 4" FLG UL SRGKN 40GAL 275PSI WS -1 4" FLG FM SRGKN 40GAL 275PSI WS -1 6" FLG FM SRGKN 40GAL 275PSI WS -1 8" FLG FM SRGKN 40GAL 275PSI WS -1 10" FLG FM SRGKN 40GAL 400PSI -1 4" FLG FM SRGKN 40GAL 400PSI -1 6" FLG FM SRGKN 40GAL 400PSI -1 8" FLG FM SRGKN 40GAL 500PSI WS -1 4" FLG SRGKN 40GAL 500PSI WS -4 4" FLG SRGKN 40GAL 500PSI OS -4 4" FLG SRGKN 40GAL 500PSI WS -8 4" FLG SRGKN 40GAL 500PSI OS -8 4" FLG SRGKN 40GAL 500PSI WS -28 4" FLG SRGKN 40GAL 500PSI OS -28 4" FLG SRGKN 80GAL 275PSI OS -1 4" FLG SRGKN 80GAL 275PSI OS -1 6" FLG SRGKN 80GAL 275PSI OS -1 8" FLG SRGKN 80GAL 275PSI OS -1 10" FLG SRGKN 80GAL 500PSI OS -1 4" FLG SRGKN 80GAL 500PSI OS -4 4" FLG SRGKN 80GAL 500PSI OS -8 4" FLG SRGKN 80GAL 500PSI OS -28 4" FLG SRGKN 80GAL 200PSI -1 4" FLG UL SRGKN 80GAL 275PSI WS -1 4" FLG FM SRGKN 80GAL 275PSI WS -1 6" FLG FM SRGKN 80GAL 275PSI WS -1 8" FLG FM EPN 860120 860170 860220 860270 860171 860172 860174 863741 Description SRGKN 80GAL 275PSI WS -1 10" FLG FM SRGKN 80GAL 400PSI -1 4" FLG FM SRGKN 80GAL 400PSI -1 6" FLG FM SRGKN 80GAL 400PSI -1 8" FLG FM SRGKN 80GAL 500PSI WS -1 4" FLG SRGKN 80GAL 500PSI WS -4 4" FLG SRGKN 80GAL 500PSI WS -8 4" FLG SRGKN 80GAL 500PSI WS -28 4" FLG 200 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. Illinois USA . or infringements resulting from the modification. when communicated to Parker Hannifin Corporation. SELLER MAKES NO OTHER WARRANTY.S. different or inconsistent terms and conditions shall become part of the contract between Buyer and Seller unless expressly accepted in writing by Seller. Illinois USA . expenses or judgments resulting from any claim that such item infringes any patent. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY INCIDENTAL.O. Such special tooling shall be and remain Seller’s property notwithstanding payment of any charges by Buyer. Seller shall have no liability for claims of infringement based on information provided by Buyer. IMPLIED. copyright. Seller’s obligation to defend and indemnify Buyer is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of such allegations of infringement. rules or regulations of any government or government agency. all prices and charges are exclusive of excise. This offer and its acceptance by any customer ("Buyer") shall be governed by all of the following Terms and Conditions. No actions arising out of the sale of the items sold hereunder or this Agreement may be brought by either party more than two (2) years after the cause of action accrues. copyrights. AT SELLER’S SOLE OPTION. proposed by Buyer in any acceptance of an offer by Seller. WHETHER EXPRESS. This Agreement shall be governed in all respects by the law of the State of Ohio. Acceptance of Seller’s products shall in all events constitute such assent.Offer of Sale The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation. Buyer’s order for any such items. including any terms in addition to. If Buyer claims exemption from any sales. 1. Buyer shall save Seller harmless from and against any such tax. trade dress and trade secrets (hereinafter ‘Intellectual Property Rights’). shortages of materials and any other cause beyond Seller’s control. 4. 11. Acceptance of any such requested modification or cancellation shall be at Seller’s discretion. Events of Force Majeure shall include without limitation. Seller shall not be responsible for any loss or damage to such property while it is in Seller’s possession or control. Any delivery dates shown are approximate only and Seller shall have no liability for any delays in delivery. delays or failures in delivery of carriers or suppliers. its subsidiary or an authorized distributor ("Seller") verbally or in writing. Payment: Payment shall be made by Buyer net 30 days from the date of delivery of the items purchased hereunder. confidential information or equipment furnished by Buyer or any other items which become Buyer’s property. trade dress. or may request to cancel all or part of this order. If any such taxes must be paid by Seller or if Seller is liable for the collection of such tax. acquired to manufacture items sold pursuant to this contract. Any claims by Buyer for omissions or shortages in a shipment shall be waived unless Seller receives notice thereof within 30 days after Buyer’s receipt of the shipment. If an item sold hereunder is subject to a claim that it infringes the Intellectual Property Rights of a third party. Terms and Conditions of Sale: All descriptions. floods. Buyer shall defend and indemnify Seller for all costs. Seller’s plant. Patents. WHETHER ALLEGED TO ARISE FROM BREACH OF CONTRACT. trade secret or any similar right. ALL OTHER WARRANTIES. Buyer’s Property: Any designs. may be considered obsolete and may be destroyed by Seller after two (2) consecutive years have elapsed without Buyer placing an order for the items which are manufactured using such property. Amounts not timely paid shall bear interest at the maximum rate permitted by law for each month or portion thereof that the Buyer is late in making payment. 6. Buyer’s acceptance of any offer to sell is limited to these terms and conditions. even if such apparatus has been specially converted or adapted for such manufacture and notwithstanding any charges paid by Buyer. occupational or like taxes which may be imposed by any taxing authority upon the manufacture. tools. Limitation Of Remedy: SELLER’S LIABILITY ARISING FROM OR IN ANY WAY CONNECTED WITH THE ITEMS SOLD OR THIS CONTRACT SHALL BE LIMITED EXCLUSIVELY TO REPAIR OR REPLACEMENT OF THE ITEMS SOLD OR REFUND OF THE PURCHASE PRICE PAID BY BUYER. acts of God. however. proposals. NOTWITHSTANDING THE FOREGOING. 9. or offer to accept return of said item and return the purchase price less a reasonable allowance for depreciation.S. EXPRESS OR IMPLIED WARRANTY. risk of loss shall pass to Buyer upon Seller’s delivery to a carrier. Changes. acts. procure for Buyer the right to continue using said item. Notwithstanding the foregoing. or directed to items delivered hereunder for which the designs are specified in whole or part by Buyer. CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND OR NATURE WHATSOEVER. use or other tax imposed by any taxing authority. discard or otherwise dispose of any special tooling or other property in its sole discretion at any time. its subsidiaries and its authorized distributors. 10. TRADE USAGE. and shall be upon such terms and conditions as Seller may require. Indemnity For Infringement of Intellectual Property Rights: Seller shall have no liability for infringement of any patents. and there are no oral or other representations or agreements which pertain thereto. 9/91-P 208 Parker Hannifin Corporation Hydraulic Accumulator Division Rockford. OR REPRESENTATION OF ANY KIND WHATSOEVER. fires. Entire Agreement/Governing Law: The terms and conditions set forth herein. drawings. acknowledgments. In no event will Buyer acquire any interest in apparatus belonging to Seller which is utilized in the manufacture of the items sold hereunder. THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO ITEMS PROVIDED HEREUNDER. Regardless of the method of delivery. combination or use in a system of any item sold hereunder. use. accidents. acceptances and sales of Seller’s products are subject to and shall be governed exclusively by the terms and conditions stated herein. Taxes: Unless otherwise indicated on the face hereof. FAILURE TO WARN OR STRICT LIABILITY. patterns. however. sale or delivery of the items sold hereunder. Buyer agrees to pay all such taxes or to reimburse Seller therefore upon receipt of its invoice. materials. molds and patterns. trade dress. shall constitute acceptance of this offer. dies. If a claim is based on information provided by Buyer or if the design for an item delivered hereunder is specified in whole or in part by Buyer. property. together with any amendments. Warranty: Seller warrants that the items sold hereunder shall be free from defects in material or workmanship for a period of 18 months from date of shipment from Parker Hannifin Corporation. NEGLIGENCE. OR ARISING BY OPERATION OF LAW. delivery shall be made F. including without limitation. trade secrets or similar rights except as provided in this Part 10. or inconsistent with those contained in Buyer’s offer. replace or modify said item so as to make it noninfringing. OR COURSE OF DEALING ARE HEREBY DISCLAIMED. INCLUDING WITHOUT LIMITATION. Any terms or conditions in addition to. No such additional. 8. Seller will defend and indemnify Buyer against allegations of infringement of U. trademark. quotations. sales. modifications and any different terms or conditions expressly accepted by Seller in writing. Force Majeure: Seller does not assume the risk of and shall not be liable for delay or failure to perform any of Seller’s obligations by reason of circumstances beyond the reasonable control of Seller (hereinafter ‘Events of Force Majeure’). offers. Delivery: Unless otherwise provided on the face hereof. Unless otherwise agreed. Seller’s acceptance of any offer to purchase by Buyer is expressly conditional upon Buyer’s assent to all the terms and conditions stated herein. OR IN TORT. U. and Seller having sole control over the defense of any allegations or actions including all negotiations for settlement or compromise. its subsidiaries and its authorized distributors are hereby offered for sale at prices to be established by Parker Hannifin Corporation. INCLUDING BUT NOT LIMITED TO. Seller will defend at its expense and will pay the cost of any settlement or damages awarded in an action brought against Buyer based on an allegation that an item sold pursuant to this contract infringes the Intellectual Property Rights of a third party. 12. GUARANTEE. copyrights. the amount thereof shall be in addition to the amounts for the items sold. fixtures. strikes or labor disputes. 7. INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING FROM OR IN ANY WAY CONNECTED WITH THIS AGREEMENT OR ITEMS SOLD HEREUNDER. 3. Special Tooling: A tooling charge may be imposed for any special tooling. at its sole expense and option. THERE ARE NO WARRANTIES WHATSOEVER ON ITEMS BUILT OR ACQUIRED WHOLLY OR PARTIALLY. trademarks. laws. The foregoing provisions of this Part 10 shall constitute Seller’s sole and exclusive liability and Buyer’s sole and exclusive remedy for infringement of Intellectual Property Rights. Trademarks. MERCHANTABILITY AND FITNESS FOR PURPOSE. together with any interest or penalties thereon which may be assessed if the items are held to be taxable. Seller may. TO BUYER’S DESIGNS OR SPECIFICATIONS.B. or inconsistent with those stated herein. Seller shall have the right to alter. Reschedules and Cancellations: Buyer may request to modify the designs or specifications for the items sold hereunder as well as the quantities and delivery dates thereof. no such requested modification or cancellation shall become part of the contract between Buyer and Seller unless accepted by Seller in a written amendment to this Agreement. 5. shall constitute the entire Agreement concerning the items sold. 2. are hereby objected to. while adding safeguards that prolong equipment life. and reservoirs reducing installation and operating costs.parker. • Supply emergency fail-safe power to complete a work safety cycle in the event of a pump or electric power failure.com/accumulator . fittings. BLADDER PRODUCTS Piston Accumulators Bladder Accumulators Diaphragm Accumulators KleenVent Reservoir Isolators BLADDER PRODUCTS Inline Pulse-Tone™ Shock Suppressors SurgeKushons Catalog HY10-1630/US Parker Hannifin Corporation 3M 5/06 DBH Hydraulic Accumulator Division 10711 N.S. and gauges by absorbing hydraulic line shocks. IL 61115 (815) 636-4100 Fax: (815) 636-4111 Web site: http://www. Parker Accumulators specifically… • Provide an auxiliary power source by holding supplemental power to be used during peak periods.Parker… your most complete source for Hydraulic Accumulators and related products. reducing pump wear.A. Second Street Printed in U. Parker’s Accumulator Products are designed to optimize the performance of your hydraulic system. This allows the use of smaller pumps. motors. Reduced operating costs and savings from less downtime and maintenance are the benefits. Rockford. • Hold necessary high pressure for long periods of time while preventing oil overheating. • Reduce costly damage to piping systems. • Protect hydraulic systems and circuit components from damage due to thermal expansion and contraction in a closed system. and saving energy.
Copyright © 2024 DOKUMEN.SITE Inc.