Current ValueParameter NSN InactivityTimerDownlinkDCH8-32: 5 InactivityTimerUplinkDCH8-32: 5 DCH to FACH Transition Time InactivityTimerDownlinkDCH64-384: 2 InactivityTimerUplinkDCH8-32: 2 UL_DL_activation_timer: 2 FACH to PCH Transition time ExtendedULDLactivationTmr: 0 PCH to Idle state transition time MSActivitySupervision: 29 TrafVolTimeToTriggerUL: 0 s FACH to DCH Transition Time TrafVolTimeToTriggerDL: 0 s Trigger FACH to DCH TrafVolThresholdULLow: 7 (1 KB) TrafVolThresholdDLLow: 7 (1 KB) HSDPA to FACH trigger time MACdflowthroughputTimetoTrigger: 5 HSDPA to FACH trigger throughput MACdflowthroughputRelThr: 0 bps T3212 (Peridic Location Update) CS_T3212: 2 QqualMin QqualMin : -18 QrxLevMin QrxLevMin : -115 Max Bit Rate HSPA/MAC-D Flow MaxBitRateNRTMACDFlow: No Limit Max Bit Rate DL PS MaxBitRateDLPSNRT: 128 Max Bit Rate UL PS MaxBitRateULPSNRT: 128 T313 T313 : 3 N313 N313 : 50 T300 T300 : 2 N300 N300 : 3 UE Tx Power on PRACH UEtxPowerMaxPRACH: 24 T314 T314 : 6 Current Value Ericsson Huawei ZTE hsdschInactivityTimerCpc For CPC Capable : 5 , hsdschInactivityTimer BeD2FStateTransTimer=5 TRbRecfgCmpDtoF : 15 Non_CPC Capable : 2 - BeF2PStateTransTimer=2 InactivityTimerPCH : 30 PSInactTmr= 5 T312Connected : 1 - BEF2DTVMTIMETOTRIG=0 N312Connected : 1 - BEF2DTVMTHD=1024 - BEH2FTVMTIMETOTRIG=5 - BEH2FTVMTHD=64 T3212 : 4 T3212=4 T3212Cs : 4 QqualMin : -18 QqualMin=-18 QqualMin : -18 QrxLevMin : -115 QrxLevMin=-115 QrxLevMin : -115 - - HsMaxDlRateDch : No Limit - R99MaxDlRateDch : 128 - R99MaxUlRateDch : 128 T313 : 3 T313=3 T313 : 3 N313 : 100 N313=20 N313 : 50 - T300=2 T3002 : 2 - N300=3 N300 : 3 - MaxUlTxPowerforint=24 MaxRACHTxPwr : 24 T314 : 12 T314=6 T314 : 4 Recommend Value Unit 5 s 2 s As per vendor minute 0 s 1000 Bytes 5 s 64 Bytes 4 Hours -18 dB -115 dBm No Limit 128 Kbps 128 Kbps 3 S 20 Times 2 S 3 Times 24 dBm 6 s Remark If > 4 hours will be change to 4 hours, if below still remain Parameter NSN msTxPwrMaxGSM : 33 msTxPwrMaxGSM1x00 : 43 gprsMsTxpwrMaxCCH : 33 Ms Tx Power Max gprsMsTxPwrMaxCCH1x00 : 43 RxLev Access Min rxLevAccessMin => GSM : 105, DCS : 95 TA Max msMaxDistInCallSetup : 255 BS Tx Power max (attenuation) bsTxPwrMax, bsTxPwrMax1x00 : 0 AFR Radio Link Timeout radioLinkTimeoutAmr : 44 AHR Radio Link Timeout radioLinkTimeoutAmrHr : 44 Radio Link Timeout radioLinkTimeout => GSM : 36, DCS : 32 Max Number of Retransmission maxNumberRetransmission : 2 Number of Multiframes noOfMFramesBetweenPaging : 2 Number of Slots Spread Trans nbrOfSlotsSpreadTrans : 32 Periodic Ms Location Update(2G/3G) timerPeriodicUpdateMs : 2 h Sacch repeat window sacchRepeatWindow : 4 T200S T200S : 300 ms T200F T200F : 200 ms Max Queue Length timeLimitCall : 10 T3101 T3101 : 3 T8 T8 : 12 T7 T7 : 20 T3103 T3103 : 6 T3107 T3107 : 6 Time Limit Handover timeLimitHandover : 5 Current Calue Ericsson Huawei MSTXPWR GSM: 33 MSTXPWR GSM: 33 DCS: 30 DCS: 30 ACCMIN => GSM : 102 , DCS : 95 ACCMIN => GSM : 102 , DCS : 95 MAXTA => Normal cell : 64 , XrangeCell : 255 MAXTA => Normal cell : 64 - - RLINKTAFR (44) & RLINKUPAFR (48) AFR RLT:56 RLINKTAHR (44) & RLINKUPAHR (48) AHR RLT:56 RLINKT for Downlink (GSM : 36 , DCS :32) , RLINKUP for Uplink (GSM : 40 , DCS : 36) RLT : 52 MAXRET : 2 IMMASSMAXSENDNUM = 2 MFRMS : 2 BSPAMFRAMS=2 TX : 32 TX : 32 T3212 : 40 (Unit : decihour in Ericsson) T3212 : 40 (Unit : decihour in Huawei) SACCH/T N200 : 5 times N200SACCH : 5 Parameter T200 in Ericsson related to parameter SIGDEL , if SIGDEL= NORMAL (T200=240ms) then SIGDEL=LONG (T200=1400ms) T200S:200 Parameter T200 in Ericsson related to parameter SIGDEL , if SIGDEL= NORMAL (T200=240ms) then SIGDEL=LONG (T200=1400ms) T200F:200 - TIQUEUINGTIMER=8 15-30 (unit in deciseconds) T3101=3 T8 in Ater Signalling => 8 second , T8 in A-interface : 25 second T8=10 - T7=10 - T3103=10 - T3107=10 HANDOVER_ REQUEST_timer (THNDREQ) => 8 second , HANDOVER_ REJECT_timer (THNDRQREJ) => 1 second TQHO=8 Recommend Value Unit ZTE MsTxPwrMax : 33 DCS : 30 GSM: 33 DCS: 30 dBm RxLevAccessMin : -100 GSM: -105 dBm DCS: -95 dBm dBm TaMax : No Limit No Limit - 0 dB BsRadioLkTmOutAMRFR : 44 44 Sacch_times BsRadioLkTmOutAMRHR : 44 44 Sacch_times BsRadioLKTmOut, MsRadioLKTmOut => GSM: 36; DCS: 32 36 Sacch_times MaxRetrans : 4 2 times BsPaMframs : 5 2 Number TxInteger : 14 32 Number T3212 : 360 4 Hours (RepeatACCH = YES) -> SACCH repeat Hardcoded 4 times T200_0, T200_5 : 5 240 ms T200_1, T200_2 : 5 200 ms rmsT11 : 6 7 s RmsT3101 : 3 3 s RmsT8 : 1 As per vendor s RmsT7 : 1.5 As per vendor s RmsT3103 : 6 As per vendor s RmsT3107 : 6 As per vendor s RmsTqho : 5 6 s Remarks Before new year, all non blocking GSM cells in East Area already modified to -105 ZTE only has BS Tx Power Min If > 4 hours will be change to 4 hours, if below still remain Need confirm why ZTE value too small Need confirm why ZTE value too small Never been adjusted Never been adjusted Never been adjusted Never been adjusted Current Value Parameter Unit NSN ZTE T300 2 2 N300 3 3 T312 Idle N312 Idle T312 Connected N312 Connected T302 N302 T304 N304 T305 T307 T308 N308 T309 T313 3 3 N313 50 50 T314 6 4 T315 N315 T316 T317 T3212Cs ATTIndCs NMOPs Kcs Kps 0 TCH 3 SDCCH 4 BCH 8 SDCCH+CBCH 14 PDTCH 6 CCH
Copyright © 2024 DOKUMEN.SITE Inc.