Home
Login
Register
Search
Home
Panasonic Inverter Vf0 Series
Panasonic Inverter Vf0 Series
March 25, 2018 | Author: zastzast | Category:
Mains Electricity
,
Alternating Current
,
Power Supply
,
Power Inverter
,
Amplifier
DOWNLOAD
Share
Report this link
Comments
Description
Motion ControlAC Inverters VF-0, VF-CE 02/2006 2 5kW 0.5 kW 2.37kW 0.Ultra-compact .Cost effective 1-phase 230V AC 0.75 kW 1.4 kW 0.Filter integrated .75 kW 1. VF-CE Product Overview VF-0 Series .Vector control .75 kW 1.AV Inverters VF-0.75 kW 1. PROFIBUS) 1-phase 230V AC 0.2kW 3-phase 400V AC 0.7 kW VF-CE Series .Multiple interfaces (RS232C/RS485.2 kW 3.Easy to use .5 kW 2.2 kW 4.5 kW 3-phase 400V AC 0.2 kW 0.0kW 2 02/2006 .Advanced technology .5 kW 2. decrease and memory functions using external switches .2 3.Ultra-compact .Easy and accurate frequency control using PLC puls output .Complete regeneration brake function 1-phase 230V AC Input types MotorPower PN [kW] 0. „rotation direction setting“.Retry function .5 2.VF-0 Series Overview Highlights . monitor“. current display“.Easy to operate using the integrated operating panel . and to set forward or reverse run direction Easy and accurate frequency control with a PLC Frequency control with a PWM signal from a PLC to the inverter is possible without analogue I/O units.75 1.75 1. and save the data.Frequency increase. PLC/FP0 VF-O Motor 02/2006 3 . Motor speed can be controlled. Brake provided not provided BFV00022DK BFV00042DK BFV00072DK BFV00152DK 3-phase 400V AC Input types MotorPower PN [kW] 0.Cost effective .4 0. „frequency setting. and data display.5 BFV00042GK BFV00072GK BFV00152GK Part No. data for function setting and parameter numbers Button to start the inverter Button to stop the inverter Up/Down buttons to change the data and output frequency. line speed. error details. BFV00074 BFV00154 BFV00224 BFV00374 Easy to operate Button to select „frequency output.8-speed control function . also to change between frequency and current display Potentiometer to set the operating frequency Display shows output frequency. current.7 Part No.2 0.„function setting“ and switching the display to show data or mode Button to change the display between the parameter No.Various types without and with brake included (1-phase) . 0. Continuous operation at less than 165V for 15ms 0. 0 to 5V. 0. over temperature (SC1 to 3). output current proportional (selection changeover) Output specifications: Max.75kW. 2. –15% of rated AC input voltage ±5% of rated input frequency Continuous operation at 165V or more. auxiliary stop (AU).0. 2.4kW: 80% or more 0.5.1.VF-0 Series Specifications Input voltage Applied motor output 1-phase 230V AC 0.4kW. digital setting (operation panel) • External analog setting signal: Potentiometer (10kW. 1. reverse run signal. oil mist or dust present IP00 Self-cooling: 0. save SW signal Base frequency: 50. panel reset (setting possible) and power supply reset Optional setting from 0. 90% RH or less (with no dew condensation) –25°C to +65°C. with no corrosive gases. arrival signal. 4 to 20mA (Connect a 200 .5. down SW. Forced-air cooling: 1. and 0Hz restart.75kW.9m/s2 (0. of retries: Optional setting for 1 to 10 times • Local setting: Potentiometer. 0.5% of selected maximum set frequency (25±10°C) for analogue setting Digital setting: 0.6G) or less Indoors.) Continuous operation at 323V or more. frequency detection. 5.75kW. overvoltage (OU 1 to 3). No.8.75 to 3.6. 1/4 or more). square torque pattern (selection changeover) Optional base frequency setting for 45 to 250Hz Optional setting for 0 to 40% 0.1 to 120 seconds Output specifications: 0 to 5V (max.5kW: 20% or more 20% or more 100% or more with connection of brake resistor (option) (built-in brake circuit) Operation Control Voltage/frequency characteristics 2nd voltage/frequency characteristics 1st and 2nd torque boost level 1st and 2nd accel. Braking time: Optional setting for 0. Forced-air cooling: 1. overcurrent (OC 1 to 3). output frequency/current proportional PWM signal (cycle 1ms) Output specifications: change over (1c) contact (contact capacity 250V AC. Please keep in mind this partial difference. low voltage (LU). reverse run signal. external reset. 10.5kW Self-cooling: 0.2 to 1. frequency Tolerable voltage variations Torerable frequency variations Instantaneous voltage drop resistance capacity Output frequency range Frequency display Frequency accuracy Frequency setting resolution Inverter control method Carrier frequency Start/Stop Forward/Reverse Jog operation Stop mode Reset function Stop frequency Instantaneous power failure restart Retry function Frequency setting signal 150% of rated output current for 1 minute +10%.8.04 to 999sec.5kW: 100% or more (short-time) 0.7kW 3-phase 380 to 460V AC (proportional to power supply voltage) 3-phase 380 to 460V AC 50/60Hz Rated output Rated output voltage Overload current rating Phases. voltage. Gain frequency: set from 0 to 250Hz Select from auxiliary stop or coast-to-stop (selection setting) 0.5. Continuous operation at less than 323V for 15ms Output frequency Input power supply Operation panel buttons or input contact1) signal (wait time setting possible) Operation panel buttons or input contact 1) signal (reverse rotation prohibit setting possible) Operating frequency: Optional setting for 0.75kW: 20% or more.5 to 250Hz Bias frequency: set from –99 to 250Hz.1. Characteristics: Linear Up to 8 preset frequency settings (optional setting) Up to 3 place settings (skip frequency band setting from 1 to 10Hz) Optional setting from 0. arrival signal. operating frequency restart (selection changeover) Retry selection: Select function OFF and details of retry fault. 7.5 to 60Hz Function OFF. explosive gases. 0 to 10V.5kW 3-phase 200 to 230V AC (proportional to power supply voltage) 1-phase 200 to 230V AC 50/60Hz 3-phase 400V AC 0. 50mA Output functions: Run signal. 15kHz) Select from 7 types (0. Accel. Acceleration/deceleration time: Optional setting each for 0. overload prealarm. 7. and decel.0kHz) (0.5A resistance load) Output functions: Run signal.5 to 250Hz.1Hz (1Hz over 100Hz)./Decel. output current. 12.0. fault warning Output frequency or line speed (selection changeover). 95% RH or less 1000m or less.5 and 15. (individual accel.7kW Output signal Open collector output Relay output Operating condition Fault details Current limit Shut-off (stop) Stall prevention function Protection Environment Display Working ambient temperature and humidity Transportation/storage temperature and humidity Altitude and vibration Atmosphere Enclosure Cooling method • Protection against Electric shock: Class I • Overvoltage category: II • Pollution degree: 2 Note: The specifications for the 200V and 400V classes are not the same.5 to 3. 5.2kW: 100% or more. 1/4W or more external resistor) • External digital setting signal: PWM signal (signal cycle: 0. Braking torque level: 0 to 100 (set between 20 levels). 1) 1a = Normally open 4 02/2006 . 1. overload prealarm. Time setting). 1mA). rotation direction Symbol indicated when protective function activates (last 4 faults are stored) Current limit can be set from 1 to 200% of rated output current Instantaneous overcurrent. operation error (OP) Overcurrent stall prevention.5.5.9 to 1100ms). Output functions: Output frequency./Decel.1Hz (50/60Hz mode) High carrier frequency sinusoidal PWM control (V/F control method) Select from 9 types (The output current must be reduced for 12. 1. Analogue setting: 0. 60Hz fixed and optional setting between 45 and 250Hz V/F curve: Constant torque.2 to 0. 1. fault warning. rating 50V DC. regenerative overvoltage stall prevention –10°C to +50°C (with no freezing). Time Multi-speed frequency setting Skip frequency setting Upper and lower frequency setting Bias/gain frequency settings External stop function With brakes Braking Regenerative braking torque Without brakes DC braking Analogue output Operates when less than stop frequency.04 to 999 seconds Select from ramp-to-stop or coast-to-stop (selection changeover) Stop signal reset. 5. 1. freuquency detection. and 10kHz) (The output current of 3. 1. overload/electronic thermal overload (OL).7kW must be reduced when set to 10kHz.5 to 250Hz Digital display ±0.6. Frequency up SW. 5 to 3.75kW 3-phase 400V 1.5 1.75 1.2 0.of medium-high voltage transformer. Ø5 mm VF0 H H1 Inverters Capacity [kW] 0. The brake resistor is either enclosed.5 W [mm] W1 [mm] H [mm] H1 [mm] D [mm] VF0 H H1 BFV00022DK BFV00042DK 78 68 110 102 100 Ø5 mm BFV00042GK W1 W BFV00072DK 8 mm D BFV00072GK BFV00152DK 100 90 130 121 115 3-phase 400V AC 5 mm BFV00152GK Note 1: 1.75kW – 3.5kW includes a cooling fan Part No.VF-0 Series Specifications Dimensions 1-phase 230V AC 5 mm 5 mm Part No. Applicable Motor Capacity [kW] 0. or built in. BFV00072GK or BFV00152GK.7kW EMC Filter 200V type 400V type Compliant to EN55022 Class A and B EN55022 Class A and B Part No.2kW – 1.5kW 3-phase 400V 2. Filters EMC filters are usually employed to reduce conducted disturbances and thus ensure constant quality in the power supply network.5kW 0.5 2.2kW 3-phase 400V 3.4 0. Class A: Limits for general industrial use. Inverter VF-0 1-phase VF-0 3-phase PN 0.7 W [mm] 130 130 160 W1 [mm] 121 121 151 W2 [mm] 110 110 140 H [mm] 130 130 130 H1 [mm] 90 90 90 D [mm] 148 161 161 BFV00074 BFV00154 W2 W1 W 7 mm 8 mm D BFV00224 BFV000334 Note 1: 1. the standards EN61800-3 (product standard) and EN55011/EN55022 (limits and methods of measurement) are important.2 3. BFV00074 BFV00154 BFV00224 BFV00374 Motor [kW] 0.4 0. BFVC9164U BFVC9164U BFVC9165U BFVC9166U Dimensions [mm] 110 x 80 x 15 110 x 80 x 15 110 x 80 x 15 216 x 80 x 15 For 1-phase 230 V AC types please select the BFV00042GK.75 1. This applies to all usage sites that are normally connected to their own individual high.7kW includes a cooling fan Brake resistor VF-0 Part No.7kW 3-phase 400V Brake resistor Part No. FN2071N606 FN3258745 02/2006 5 .75 0. whereby the following limits must be met: EN55011/EN55022. For use. VF-CE Series Overview For the 0. cUL) • Cost effective • Energy efficient • Types: 1-phase 230V AC: 0. 6 02/2006 .25kW to 4. RS232/RS485.75 to 4.8 x MN torque for 60s (MN = rated load torque) Multiple interfaces (digital/analogue I/O.25 to 2.0kW (3-phase 200V AC power supply also possible with restrictions) For Automation interface AIF Available Communication I/O modules BFVC904C Keypad BFVC9503 RS232C/RS485 Communication module BFVC9901 PROFIBUS AIF DP slave interface System units AIF For Function interface FIF FIF BFVC90XY Standard I/O Modul (always included) with digital and analogue I/O BFVC9902 PROFIBUS DP slave interface FIF For detailed description of the modules see page 8/9. PROFIBUS) • Operator module with copy function • International approvals (CE. UL.0kW power range • • • • • Ultra-compact Integrated filter with EMC interference to class B Vector control and V/f control Up to 1.2kW (1-phase 115V AC power supply also possible with restrictions) 3-phase 400V AC: 0. For the first time ever.0kW inverter for side mounting of 1. lower costs and a VF-CE inverters even more compact than before.16HP 0.2kW inverter Inverter configurator software for the inverters and VF-CE brake resistor on request 02/2006 7 .37 kW digital and analogue inputs/outputs (always included) RS232C and RS485 (multi-drop) for connection to computer or PLC Connection cable between VF-CE RS232C port and computer RS232C port Connection cable between VF-CE RS232C port and PLC RS232C port.12kW 1 ~ 115V AC: 0.75kW 1. BFVC 904C BFVC 9060 BFVC 9062 BFVC 9065 BFVC 90XY BFVC 9503 BFVC 9503 PCAT BFVC 9503 PLC BFVC 9901 BFVC 9902 BFVC 9161U BFVC 9162U BFVC 9164U BFVC 9165U BFVC 9166U BFVC 9999 BFVS 29902V2 Braking resistors Swiveling mounting bracket Motion Control Software Ver.24HP 1HP 2HP 3HP 120 x 60 x 140 120 x 60 x 140 180 x 60 x 140 240 x 60 x 140 240 x 60 x 140 3-phase 400V AC: 0.8 x MN for 60s) and has low level open-circuit power consumption. SUB-D 9pin PROFIBUS interface for connection on AIF PROFIBUS interface for connection on FIF for 1-phase 0. the EMC filters are not connected externally in series.5kW inverter for 3-phase 2.5 and 2.4HP 180 x 60 x 140 240 x 60 x 140 240 x 60 x 140 240 x 100 x 140 Other types available on demand Accessories / Interfaces Type Operator module Remote control set with operator module 2m cable for remote control set 5m cable for remote control set Standard I/O module RS232C / RS485 communication module Cable RS232C to PC-AT Cable RS232C to PLC PROFIBUS AIF module PROFIBUS FIF module Description for entering the parameters.5kW 3 ~ 200V AC: 2.75kW 1. This function is particularly useful for drives with strong fluctuating loads or high starting inertia.2kW inverter for 3-phase 4.0kW BFVCE0074A BFVCE0154A BFVCE0224A BFVCE0404A 3 ~ 320 – 550V AC 3 ~ 320 – 550V AC 3 ~ 320 – 550V AC 3 ~ 320 – 550V AC 1HP 2HP 3HP 5. Since many small EMC components are located at the points on the printed circuit board where interference is actually generated. with copy function for flexible manual operation with cable connection Part No.75kW – 1. 2. Integrated EMC filter to class B – new for VF-CE inverters VF-CE inverters offer a new concept for preventing electrical interference.5kW 2.75kW – 1.75kW 3 ~ 200V AC: 1.25kW 0. as well as for sensorless speed control of motors requiring slip compensation.5kW inverter *) for 1-phase 2.2kW Part No. it can be prevented right at the source.2kW 4. Performance 1-phase 230V AC: 0.37kW 0.25 / 0. the VF-CE inverter achieves considerably higher torque in comparison to conventional V/f control (maximum torque = 1.18kW 3 ~ 200V AC: 0.5kW 2.2kW inverter for 3-phase 0.2kW 0.0 *) 0.VF-CE Series Specifications Improved vector control increases efficiency Due to vector control. The result is a higher filter performance. Supply Voltage (45 – 65Hz) Supply Voltage Power PN for USA Dimensions (H x W x D) in mm (1 ~ 115V AC / 3 ~ 200V AC) BFVCE0022A BFVCE0032A BFVCE0072A BFVCE0152A BFVCE0222A 1 ~ 180 – 264V AC 1 ~ 180 – 264V AC 1 ~ 180 – 264V AC 1 ~ 180 – 264V AC 1 ~ 180 – 264V AC 1 ~ 115V AC: 0. If the standard I/O module is necessary in the application. . The PROFIBUS modules Two different PROFIBUS modules permit open communication in accordance with the international EN50170 standard.Electric isolation from control/power section RS485 interface: .4 / 4. the PROFIBUS AIF module can be used as the automation interface. distance between 2 stations: 1200m .4 / 4. (AC 240V/3A.Access to all parameters . 1 stop bit.18A) The standard I/O module order number BFVC 90XY is included in the VF-CE inverter. and offers a variety of connection possibilities..6 / 19. The RS232C / RS485 communication module Two serial interfaces allow the VF-CE inverter to communicate with the application device and have its parameters adjusted by a controller simultaniously. The PROFIBUS FIF module is used instead of the standard I/O module.6 / 19.8 / 9. 1 start bit.Drive profile: DRIVECOM Profile 20 . direct connection of peripherals such as PLC. The standard I/O module It provides parallel.Max.2 kBaud . 90 (with repeater) .DC supply: internal (5V) .2 / 2.Information message format: 7 bits ASCII.Bit rate: 1.8 / 9.2 kBaud . It needs not be ordered separately. 1 start bit..Max. DC 24V/2A … 200V/0. 1 stop bit. Standard I/O module BFVC90XY Number Analogue input Analogue output Digital inputs Frequency input Digital output 1 1 3/4 1/0 (0 … 10kHz) 1 Voltage 0 … 10V -10 … +10V 0 … 10V PLC level 0/15V (HTL) 0/24V Current 0/4 … 20mA 2mA Resolution 10bits 10bits 10bits 10/50mA One relay output (changeover contact) is integrated into the system unit as standard. 1 parity bit (even) .Information message format: 7 bits ASCII.VF-CE Series The VF-CE inverter’s interfaces 1. cable length: 1.Access to all parameters Profibus Interface AIF BFVC9901 Profibus Interface FIF BFVC9902 8 02/2006 . parts 1 and 3) . 1 parity bit (even) . RS232C interface: .Number of stations: max.6 kBaud .PROFIBUS status: Slave .2 / 2.2km (depends on baud rate and cable) .Bit rate: 9.DC supply: internal RS232C/RS485 communication interface BFVC9503 3.Number of stations: 32 (with repeater 125) .Communication profile: PROFIBUS-DP (DIN 19245. etc.Bit rate: 1. 2. sensors. 12 MBaud (automatic detection) . 5mm BFVC9062 BFVC9065 2m 5m 02/2006 9 . (cut-out 45. a protective rubber holder is included.VF-CE Series Operator module The VF-CE inverter operator module keypad The operator module allows you to enter or change the VF-CE parameters as well as display the current drive parameters.3 x 45. see below).7Nm Control cabinet sheet thickness 0. The VF-CE inverter operator module can be directly plugged into the VF-CE AIF interface or operated as a remote control set with a 2m or 5m cable. It is available as an option. Hand terminal To comfortably operate the VF-CE inverters via the hand-held terminal.2 Change to function bar 1 < > function bar 2 - -- To right/left in an active function bar Operator module keypad Increase/decrease value Store Parameter/Acknowledgement BFVC904C ENTER The remote control set with operator module The operator module (BFVC904C) is already integrated. the keypad can be mounted in switch-gear cabinets and operator consoles. Available cables Part No. Front panel mounting After removing the protective rubber holder from the remote control set. The remote-control set can also be installed in control cabinets and operator consoles. The VF-CE parameters can be saved in the operator module (BFVC904C) and simply copied to another VF-CE inverter. The keypad also allows for remote programming if the inverter is not easily accessible. Length 1 2 3 4 5 Baseplate Seal Keypad Screw 0.Time-consuming parameter setting for larger applications is therefore no longer required and errors are reduced accordingly.3mm). The 2m or 5m cables are supplied separately (Part No. Key functions of the operating module: Enable inverter RUN STOP Inhibit inverter or quick-stop 1 --. The operator module is not included in the VF-CE inverter.5mm .1. 5%/°C 0 .e. 8kHz. motor becoming unstable..VF-CE Series Specifications Control method Operating frequency Maximum torque Torque speed range V/f control (linear. over-voltage. 16kHz 1. 4kHz. 27 … 1000MHz (casing) Colour burst EN 61000-4-4 3/4. ground fault.7g (Germanischer Lloyd.. i. 1. 1kV phase-phase. i. 2kV / 5kHZ Surge EN 61000-4-5 3. thermo-couple input for monitoring motor temperature. i. fixed speeds. square). 1.e. constant speed) Min.0Hz ( 0 … MN) sensorless speed control 1 : 50 ( based on 50Hz) 0.1Hz 3 … 50Hz Sensorless speed control Generator operation (monitored internally) Filter Skip frequencies Other standard features General technical data/Operating conditions Resistance to vibration Permissible temperature ranges Acceleration restistance up to 0.5% 3 … 50Hz ±0. 10V / m.e. motor overheating (input for thermo-couple) Safe separation from mains. general conditions) Transport -25°C … +70°C Storage -25°C … +60°C Operation -10°C … +55°C above +40°C the rated output current is to be reduced by 2. linear and S-ramp. four parameter programs can be switched online. 4000m amsl above 1000m amsl the rated output current is to be reduced by 5%/1000m Permissible installation height Mounting position Protective measures against Total insulation against control-circuits Degree of protection Conformity Emitted interference Interference immunity Insulation resistance Approvals Vertical Short-circuit.2/50µs.e. if motor rated power = inverter rated power 1 : 10 (3 … 50Hz. double basic insulation in accordance with EN 50178 IP20 CE low-voltage guideline (73/23/EEC) Requirements as per EN 50081-1 Limiting value class A as per EN 55011 Limiting value class B as per EN 55022 Requirements as per EN 61800-3 immunity to interference Requirements Standard Severity ESD EN 61000-4-2 3. output frequency Speed range Accuracy Smooth running Integrated braking transistor Integrated as standard-class B Up to 3 skip frequencies can be set to avoid resonance Motor parameter adaptation and correction. 2kV phase-PE Over-voltage category III in accordance with VDE 0110 UL 508 Industrial Control Equipment UL 508C Power Conversion Equipment 10 02/2006 . vector control Either 2kHz. 8kV with air discharge 6kV with contact discharge HF irradiation EN 61000-4-3 3. bipolar set-point processing.8 x MN for 60s. i. 1ms terminal sampling time. 0 4.0 4.0 0. 65 Hz + 0 % 3/PE AC 100 V ..34 BFVCE0022A 0.2 1.6 3.6 2. W Output power +UG.8 3~ 0 .3 3/PE 9.0 Imains[A] Imains[A] Sr[kVA] PDC[kW] IR[A] 4) 3.1 – 7.5 6. 264 V + 0 % .6 1/N/PE 15. 650Hz 60 100 – – 180 x 60 x 140 1.3 1/N/PE 5) – 18..0 1/N/PE AC 180 V .5°C 4) Possible for other types with different application conditions: Operation with increased rated output current and the same load change 5) Operation only with mains choke 6) Select the mains choke for an overcurrent of 160% for at least 60s 02/2006 11 ..0 6. 45 Hz .4 9.5 1.2 14.0 7.0 % .6 IN [A] [mH] H x W x D [mm] m [kg] Printed in bold = Data for operation at 8kHz chopper frequency (default setting) 1) For operation with power-adapted motors additional power to be taken from the DC bus 2) Currents for periodic load change: 1min overcurrent with Imax and 2min basic load with 75 % I r 3) Chopper frequency is reduced to 4kHz if ϑmax reaches ..0 4.0 BFVCE0152A 2.2 3. 65 Hz + 0 % not possible 1/N/PE 1/N/PE 5..0 12. 264V + 0 % .0 % .6 6.4 3..5 2.8 0. 264 V + 0%..4 3/PE 12.5 – 240 x 60 x 140 1. 650Hz 3~ 0 .2 3.8 40 – – 120 x 60 x 140 0.0 3. Vmains / 0 .0 3.0 BFVCE0072A 1. permissible 2kHz sin output current for 60s 4kHz sin at chopper frequency 2) 8kHz sin 16kHz sin 3) Output voltage without mains choke with mains choke Power loss (operation with Ir8) Required mains choke 6) Rated currents Inductance Dimensions Weight Pr [kW] Pr [hp] EMC filter integrated Umains[V] UDC[V] 0.0 % . 370 V + 0% 1/N/PE 9.0 BFVCE0222A 1/N/PE AC 180V ..0 % ..3 IR[A] IR[A] Imax[A] IR[A] IR[A] UM[V] UM[V] UPV[W] 30 – – 120 x 60 x 140 0..2 14.2 9.0% --.65 Hz + 0% DC 140 V .1 2..1 6.2 – – 240 x 60 x 140 1.8 1.5 9.9 3/PE 5..0 7.25 0..6 130 18.. 45 Hz .5 1.75 1.68 DC bus operation not possible 1. approx.0 2.... -UG 1) Rated output current at 2kHz sin chopper frequency 4kHz sin 8kHz sin 16kHz sin 3) Max.6 – 4.6 3.7 2.5 2.7 1.4 1. 94% Umains / 0 .6 10.9 0.VF-CE Series Specifications 1-phase 230V AC Typical Motor Power 3-phase asynchronous motor (4-pole) VF-CE type Mains voltage Alternative DC supply Data for operation with 1/N/PE or 3/PE Rated mains current without mains choke with mains choke Output power U.7 1.5 2.0 – 2.. 45 Hz .5 BFVCE0032A 0.37 0.5 10.1 – 9.0% ..5 6.. V.4 2.0% . 200V) Instruction Manual Inverter VF-CE COMPACT Operating Instructions VF-CE Inverter RS232C/RS485 Communication Module Technical Specifications Inverter VF-CE Compact Easy User’s Guide VF-CE Inverter PROFIBUS AIF Module DP Slave Operating Instructions VF-CE Inverter PROFIBUS FIF Module DP Slave Operating Instructions EMC Guidelines for the VF-0 Series Inverter Paper PDF x x x x x x x x x x x x Paper versions can be ordered with the above product number..5 2. W Sr[kVA] Output power +UG.8 7. V...1 14.0%.75 1.6 2.8 9.0 % .9 Printed in bold = Data for operation at 8kHz chopper frequency (default setting) 1) For operation with power-adapted motors additional power to be taken from the DC bus 2) Currents for periodic load change: 1min overcurrent with I max and 2 min basic load with 75% I r 3) Chopper frequency is reduced to 4kHz if ϑmax reaches .6 5..0 40 BFVCE0404A EMC filter integrated Mains voltage Umains[V] Alternative DC supply UDC[V] Data for operation with 3/PE AC 400V or DV 565 V Rated mains current without mains choke Imains[A] with mains choke Imains[A] Output power U.9 5. section motion control/inverters/manual download (New users have to register first)..com..0 % .5 12.. Vmains / 0 . 550V + 0% is only permissible with break resistor! Manuals Order Number ARCT1F328E ARCT1F351E ACGM0180V20EN ACGM0181END ACGM0184END ACGM0182END ACGM0183V20EN VF0 Leaflet V11EN Manual Information Compact Inverter VF-0 Series (1-phase.1 4.9 0.6 100 – 130 – BFVC9165U 240 x 60 x 140 1. PDF versions can be downloaded from the internet free of charge: www.7 3. 650 Hz 60 – BFVC9164U 180 x 60 x 140 1.0 % .4 2. 65 Hz + 0 % DC 450 V .4 5.5 3..5 6. -UG 1) PDC[kW] Rated output current at 2kHz sin 4) IR[A] chopper frequency 4kHz sin 8kHz sin IR[A] 16kHz sin 3) IR[A] Max.9 2.4 8.9 3.6 3.6 3.3 2.2 240 x 60 x 140 1.0 BFVCE0224A 5) 4..5 5. 550 V + 0 % .5 9... 94 % Umains / 0 .7 0. 775 V + 0 % 3.2 14... 12 02/2006 .4 5.6 3.2 9.9 2...8 6.VF-CE Series Specifications 3-phase 400V AC Typical Motor Power Three-phase asynchronous motor (4-pole) VF-CE type Pr [kW] Pr [hp] 0. permissible 2kHz sin Imax[A] output current for 60 s 4kHz sin at chopper frequency 2) 8kHz sin IR[A] 16kHz sin 3) IR[A] Output voltage without mains choke UM[V] with mains choke UM[V] Power loss (operation with Ir8) PV[W] Required mains choke – Required brake resistor 5) Type Dimensions H x W x D [mm] Weight m [kg] 3/PE AC 320 V .6 8.1 3.0 BFVCE0154A 5) 2.1 2.6 0. 45 Hz .panasonic-electric-works.3 1.4 5.5°C 4) Possible for other types with different application conditions: Operation with increased rated output current and the same load change 5) Operation at mains voltages 484 V .3 8.1 3~ 0 ..7 1. 650 Hz 3~ 0 .3 5.2 3.0 BFVCE0074A 5) 1. 200V) Instruction Manual Compact Inverter VF-0 Series (3-phase. approx.4 1.6 180 – – 240 x 100 x 140 2. 170/ 110.VF-CE Series Dimensions a k c g Dimensions in mm a b3) b1 b2 b3 c BFVCE0022A BFVCE0032A BFVCE007xA 60 BFVCE015xA 1) BFVCE022xA 1) >100 mm 213/243/263 148 120 273/303/323 208 180 78 30 63 50 333/359 /363 268 240 2) b2 b1 b d c1 c2 130....230/ 170.200/ 180.....5 28 250..260/ 2) 280.140/ 120..5mm 28mm ? b1 c1 b2 b d c2 d e g k > 100 mm b3 c2 e 1) Lateral Mounting only possible with swivel mounting unit BFVE9999 2) with BFVCE9999 3) differrent sizes depend on way of mounting using the Fixing Rails 02/2006 13 ..200/ 140 c3 190..295 / 240..290 100/162 2) e >100 mm b3 g k c2 e > 100 mm a k c g BFVCE0404A a b b1 b2 b3 c 100mm 333mm 268mm 240mm 78mm 50mm 103mm 50mm 255mm 140mm 6.260 140 6....... 486DX4 100MHz processor and 8MB RAM (better Pentium 133MHz. VF-8E and VF-8X. 2.Software Motion Control Ver. 16MB RAM) í Video card with 640x480 resolution (better 800x600) í MS Windows 95®/98®/2000/MS Windows NT®/Windows XP í Inverter VF-CE. It supplies the necessary tools for: í Creating new projects or opening projects from archives í Setting up and establishing communication with the drive(s) í Monitoring a drive’s operation í Sending commands to a drive í Providing on-line help Project Navigator Project Navigator is the active project managment window. Functionality í Parameter entry í Test operation (Start/Stop. By double-clicking on the tree branches. Forward/Reverse. it is possible to: í Have access to the communication settings in order to establish communication with the drive(s) í Have access to edit the parameters (parameters are grouped by common theme) í Make one’s own parameter groups with the PUG Wizard (Parameter User Groups) based on application/user needs 14 02/2006 . Acceleration/Deceleration.) í Saving and documenting settings í Automatic drive selector í Quick launch window í Project navigator í Status monitor í Fault screen Motion Control system requirements: í Personal computer with min.0 The configuration software for Panasonic inverters Motion Control is the parameter setting software from Panasonic that allows for integrated communication with all inverters which are equipped with RS232C or RS485 serial communication interfaces. VF-8E or VF-8X The Quick Launch Window The Quick Launch Window is the starting point for the configuration environment. etc. including the Panasonic inverters VF-CE. etc. 2. voltage. and current. They immediately show the relationship between output frequency. without detailed knowledge of the internal inverter. Typical functions include: Starting/stopping the inverter.. From here it is possible to: í Start and stop the drive í Change motor direction from forward to reverse í Control the drive’s frequency setting by drag-rotation of the speed dial with the mouse pointer or by directly entering a value in the frequency display field í Set/reset important parameters The Command Window can be opened by an icon on the toolbar User Library for Control FPWIN Pro This library offers 20 function blocks that control the inverter series VF-CE (also the older VF-8E/8X series) via serial interfaces in the PLCs (RS232C. writing parameters.Software Motion Control Ver. Command Panel The Command Panel allows direct control of the drive from the configuration software. Further parameters and values can be selected. RS485). The Trend Window can be opened by an icon on the toolbar. Product-Number: NCL-ISC-LIBD 02/2006 15 . changing the set-point frequency.0 Editing Parameters The Parameter Edit windows display common groups of parameters with the default values that pertain to the selected drive. which can be very helpful in confirming proper operation and in troubleshooting performance problems. reading status information. or between two drives regarding the currently selected parameters Trend Window The real-time trend graphs provide constantly updated and easy-to-interpret snapshots of drive operation. From these windows it is possible to: í Edit the drive(s) parameters í Upload into one or more drives or download a set of parameters from a drive í Start a comparison between the current project and the drive. changing rotation direction. (0852) 2956-3118. Tel. Fax 1-908-464-8513. www. Ltd.at Ennshafenstraße 30. Ltd.o.jp/e-acg/ 101 Thompson Road. www. Singapore 307591. N.P. Tel.nl Prumyslová 1. 16/F. Ferlina). 5684 PJ Best. Fax (01) 4601131.com Rudolf-Diesel-Ring 2.panasonic-electric-works. www. Fax (06253) 5689 02/2006 Copyright © 2005 • Printed in Germany 6075 eu en 12/05 . 6343 Rotkreuz. www. Fax (08024) 648-111. Kowloon.ch Sunrise Parkway. (040) 6977000. Dong San Huan Bei Lu. Fax (045) 6700444. Fax (0852) 2956-0398 1048 Kadoma. MK14 6LF. Kadoma-shi.A. Hong Kong. Panasonic Electric Works (Hong Kong) Co. Tower 2.panasonic. Tel. Ltd. France Panasonic Electric Works Sales Western Europe B. 5. Tél.V. Fax (91) 3292976. www.com Josef Madersperger Str. Ltd. Tel.V. Fax (040) 6977099. Fax (041) 7997055.panasonic-electronic-materials. Panasonic Electric Works Asia Pacific Pte. Nordic Countries Panasonic Electric Works Nordic AB PEW Fire & Security Technology Europe AB Portugal Panasonic Electric Works España S. Tel. 19272 Sollentuna. Spain Panasonic Electric Works España S. (21) 4812520. (0499) 372727.l.panasonic-electric-works.co. (045) 6752711.r.panasonic-electric-works. United Square. Japan.panasonic-electronic-materials.it Viale Elvezia 18.R. 91371 Verrières le Buisson CEDEX. 4470 Enns. Osaka 571-8686.se Citadellsvägen 23. (02) 33604525.panasonic-building-materials.cz French Branch Office. 20154 Milano (MI). (0 72 23) 8 83. (08024) 648-0. Fax (0499) 372185.com Portuguese Branch Office. Fax 01 64622809. #25-03/05.mew.panasonic-electric-works. Building No. Tel. 1-908-464-3550.com De Rijn 4. (041) 7997050. 28042 Madrid.l. (5680 AE Best). Fax (01908) 231599. Tel. 07974. New Providence.panasonic-electric-works. Fax 374 799 999.uk Via del Commercio 3-5 (Z. Tel. Tél. 374 799 990.panasonic-electric-works. (08) 59476680. Tsimshatsui. 83607 Holzkirchen.co.. 2362 Biedermannsdorf. Fax (08024) 648-555.fr 26 Allée du Clos des Charmes. Italy Panasonic Electric Works Italia s. Milton Keynes. www. 21118 Malmö. (010) 6590-8646. www. Tel. 37012 Bussolengo (VR). Tel. North & South America USA PEW Corporation of America Head Office USA 629 Central Avenue.panasonic-fire-security. Tel. Beijing.A. www. 2750-277 Cascais. Tel. Czech Republic Panasonic Electric Works Czech s.A.. (06) 6908-1050. The Gateway. Tel.com Sjöängsvägen 10. 25 Canton Road. B.de Dublin. www.es Grundstrasse 8. PEW Building Materials Europe s.panasonic-electric-works.panasonic-electric-works. (91) 3293875. www. Fax 01 60135758. 34815 Planá. 01 64622919. PEW Electronic Materials France S. (Postbus 211).panasonic-electric-works. Sweden. Tel.r.panasonic-electric-works. 2. Tel. San Severo 20.uk Asia Pacific / China / Japan China Hong Kong Japan Singapore Matsushita Electric Works (China) Co. www. Tel.L. 44. Tel. 77090 Collegien. www. Tel. www. www. (01) 4600969. www.I.Global Network Services Global Network North America Europe Asia Pacific China Japan Panasonic Electric Works Please contact our Global Sales Companies in: Europe Headquarters Austria Panasonic Electric Works Europe AG Panasonic Electric Works Austria GmbH PEW Electronic Materials Europe GmbH Benelux Panasonic Electric Works Sales Western Europe B. Germany Panasonic Electric Works Deutschland GmbH Ireland Panasonic Electric Works UK Ltd. Fax (02) 33605053. Fax (21) 4812529 Barajas Park. Chaoyang District.com Rudolf-Diesel-Ring 2. Fax (0 72 23) 8 83 33.panasonic-electric-works. 83607 Holzkirchen. Fax (06) 6908-5781.co.J. Matsushita Electric Works. (06255) 5473. 2013. www. www.r. Fax (08) 59476690.pewa. Fax (0 22 36) 4 61 33. (0 22 36) 2 68 46. www. Avda Adelino Amaro da Costa 728 R/C J. Tel. Tel. Linford Wood. Switzerland Panasonic Electric Works Schweiz AG United Kingdom Panasonic Electric Works UK Ltd. Fax (010) 6590-8647 Rm1601. 01 60135757. Netherlands.panasonic-electric-works. Beijing Fortune. (01908) 231555. (08024) 648-0.
Report "Panasonic Inverter Vf0 Series"
×
Please fill this form, we will try to respond as soon as possible.
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
Copyright © 2024 DOKUMEN.SITE Inc.