Champ® NVMV SeriesEx-Protected Luminaire for IEC and ATEX Applications options and accessories.Header Champ®Text NVMV Series . optical light sources and luminaire placement. Our global product offering provides energy-efficient solutions that reduce total cost of ownership for our customers through superior photometry. providing faster. • HPS lamps restrike in 10-30 seconds with the instant restrike option (IR) should lamp extinguish due to system voltage drop or momentary loss. Quick-Clip secures the housing to the cover. Reduce inventory costs and provide greater flexibility for engineering designers. and safer luminaire installation. Our breadth of product. energy-efficient luminaires suitable for global applications and specifications. as gases will not enter the lamp chamber and control gear housing. allow us to partner with customers in any application. This provides better T-ratings. customers and distributors. Cooper Crouse-Hinds lighting products build upon over 100 years of harsh and hazardous expertise. KEY PRODUCT DIFFERENTIATORS • One product offering for global applications. • Identical mounting cover for IEC and NEC applications regardless of wattage. 2 . • Available with the Champ Quick-Clip. The Champ® family has the required IEC and ATEX certifications to provide solutions for specification requirements around the world. Optional built-in cut-off feature will shut off the instant restrike to avoid continuous high energy pulsing when lamp is inoperative or nearing end of life (pending). along with outstanding services and know-how. easier.Ex-Protected Luminaires for IEC and ATEX Applications Cost-effective. providing lighting solutions that enhance productivity without ever sacrificing safety. • Restricted breathing (Ex nR) protection is standard. and other industrial process flammable gases or vapors will be present facilities. LNG. LNG. chemical Pacific Rim Offshore drilling. dockside and other heavy industrial applications corrosion and rough usage are problematic • In areas where combustible dusts or fibers may be present 3 . LNG. petrochemical. offshore drilling. vibration. dust. refining. refineries. IEC 60079-15 II 3 G Ex nR II T*.. shipbuilding. as well as Zone 21 dust applications. petrochemical Australia Oil and gas exploration. refining.Gc • Marking to 94/9/EC: • EC – Type examination: LCIE 09 ATEX 1002 Application in Zone 21 and 22 areas acc. chemical. offshore developments. petrochemical.. Champ NVMV Series provides an integrated ballast with thermal cut-off functionality incorporated into the control gear. chemical. heavy industries Middle East Oil and gas extractions.. land-based drilling. EN 60529 IP66 APPLICATIONS IEC and ATEX certifications allow you to specify the NVMV for key geographical markets to serve key industries: Latin America Refining. chemical. • In installations where moisture.250W (Small Housing) NVMV 250W . In the event of abnormal temperatures or when the lamp approaches end of life. EPC designing. waste or sewage treatment facilities. chemical North America LNG. heavy industries Asia LNG.PRODUCT FAMILY OVERVIEW The Champ NVMV design is optimized for Zone 2 gas applications (with standard restricted breathing Ex nR protection). IEC 61241-1 II 2 D Ex t IIIC T. power generating. chemical. EPC designing.ºC(*) Db IP66 • Marking to 94/9/EC: • EC – Type examination: LCIE 09 ATEX 3008 General per both application Zone 2 and 21 • Temperature ambient of use: -45ºC to +55ºC • Electromagnetic compatibility: EN 61000-6-4 • Degree of protection: acc. the cutoff functionality protects the ballast from overheating or burning out.. petrochemical. NVMV 70W . power generating. dirt. offshore drilling. refining. offshore drilling Europe Refining. power generating Africa Exploration and oil extraction. • In areas where ignitable concentrations of petrochemical. petrochemical. EPC designing NVMV Ex-Protected Luminaires are suitable for applications in Zone 2 / Zone 21 / Zone 22 • In manufacturing plants.400W (Large Housing) NVMV CERTIFICATIONS Application in Zone 2 area acc. totally protected against dust Second 6 . Ex (or Ex) – Explosion protected in accordance with ATEX II – Group II surface industries (above ground) 3 – Category 3 equipment (suitable for use in Zone 2) Note: Category 2 is suitable for use in Zone 1 G – Suitable for atmosphere containing gas Note: D is suitable for atmospheres containing dust 4 t Explosion protected Protected by enclosure Dust group classification Temperatures (see tables on page 5) Equipment protection level D . 230V 60Hz CERTIFICATION DECODING “Type of Protection” refers to luminaire construction Ex nR II T.. 1⁄2”NPT and 3⁄4” NPT & 1” NPT cable entries (1 1⁄2” NPT for stanchion only) 3 Core 6mm2 max.protected against strong water jets from all directions . Protected by Enclosure from Dust Ingress Equipment protection level G . Wall Mount. IEC 60079-10-2 • Ballast housing and mountings . Stanchion Mount.Dust b .. 6 x 6mm2 for looping (available upon request) Ceiling Mount. (standard). 250W.copper-free aluminum and stainless steel (large housing .ºC Db IP66 Explosion protected “ATEX Classification” refers to application Restricted breathing enclosure Ex nR II T. 100W.Gc – Explosion Protected Restricted Breathing Enclosure Gas group classification Ex t IIIC T.ºC Db IP66 EN 60079-0. Pendant Mount E27 or E40 HSE/HST (high pressure sodium lamp) and HIE (metal halide lamp) 70W. M25..Gas c . Gc IIIC T. M32.Zone 2 Example: Temperatures (see tables on page 5) II 3G i.copper-free aluminum • Exterior hardware .Ex-Protected Luminaires for IEC and ATEX Applications NVMV STANDARD SPECIFICATIONS GAS TYPE OF PROTECTION COMPLIANCE ATEX CLASSIFICATION ATEX CERTIFICATE AREA CLASSIFICATION MATERIALS AND FINISHES ENTRY TERMINATION INSTALLATION LAMP HOLDER LAMP TYPE LAMP POWER CONTROL GEAR RE-LAMPING BURNING POSITION INGRESS PROTECTION WEIGHTS ELECTRICAL SUPPLY DUST Ex nR II T.... 150W.stainless steel only) Up to 4 x M20.Champ® NVMV Series . 240V 50Hz and 220. IEC 60079-10-1 Zone 21 and 22 acc. 230. thermal cut-off functionality incorporated into control gear Access via restricted breathing lamp chamber Base up.stainless steel (type 304) • Reflectors (dome and angle) . EN 60079-15 EN 60079-0....ºC Db IP66 – Explosion Protected..e.Krydon® fiberglass-reinforced polyester • Globes ..Zone 21 Ingress Protection First 6 .heat and impact-resistant glass • Guards . up to 25° off vertical IP66 to EN 60529 See pages 7 and 10 220.. EN 61241-1 II 3 G II 2 D LCIE 09 ATEX 1002 LCIE 09 ATEX 3008 Zone 2 acc.Gc Ex t IIIC T. and 400W Integrated ballast. Zone 2) Ex nR II T. any fixture with the T-rating in this table can be used.250W (Small Housing) GAS (Class I...400W (Large Housing) GAS (Class I.TEMPERATURE PERFORMANCE Refer to temperature performance data tables (below) to select luminaire that is suitable for your area specifications. Zone 21) Ex t IIIC T.Gc Catalog Number Example Watts NVMVS1MC255 * L0 250W NVMVS1MC405 * L0 400W NVMVM1MC255 * L0 250W Lamp Type HSE/ HST (HPS) HIE (MH) NVMVM1MC405 * L0 400W Rated Ambient °C 40 50 55 40 50 55 40 50 55 40 50 55 Lamp Holder E40 E40 E40 E40 With G303 Globe Only T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 With G303 Globe and Reflector T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T2 T2 DUST (Class II.Db With G303 Globe Only 137ºC 147ºC 152ºC 159ºC 169ºC 174ºC 137ºC 147ºC 152ºC 159ºC 169ºC 174ºC With G303 Globe and Reflector 137ºC 147ºC 152ºC 175ºC 185ºC 190ºC 137ºC 147ºC 152ºC 193ºC 203ºC 208ºC 5 ..Db With G34 Globe Only 99ºC 109ºC 114ºC 99ºC 109ºC 114ºC 122ºC 132ºC 137ºC 168ºC 178ºC 183ºC 99ºC 109ºC 114ºC 99ºC 109ºC 114ºC 122ºC 132ºC 137ºC 168ºC 178ºC 183ºC With G251Globe Only 109ºC 119ºC 124ºC 117ºC 127ºC 132ºC 140ºC 150ºC 155ºC 174ºC 184ºC 189ºC 109ºC 119ºC 124ºC 117ºC 127ºC 132ºC 140ºC 150ºC 155ºC 194ºC 204ºC 209ºC With G34 Globe and Reflector 104ºC 114ºC 119ºC 104ºC 114ºC 119ºC 140ºC 150ºC 155ºC 189ºC 199ºC 204ºC 104ºC 114ºC 119ºC 104ºC 114ºC 119ºC 140ºC 150ºC 155ºC 189ºC 199ºC 204ºC With G251 Globe and Reflector 109ºC 119ºC 124ºC 128ºC 138ºC 143ºC 140ºC 150ºC 155ºC 218ºC 228ºC 233ºC 109ºC 119ºC 124ºC 128ºC 138ºC 143ºC 140ºC 150ºC 155ºC 218ºC 228ºC 233ºC Cat No.. Atmospheres that contain diethyl ether and have an ignition temperature of 160°C require a luminaire with T4 ratings.. /230V.Gc Catalog Number Example† Watts Lamp Type NVMVS1MC075 * 00 70W NVMVS1MC105 * 00 100W NVMVS1MC155 * 00 150W HSE/ HST (HPS) NVMVS1MC255 * 00 250W NVMVM1MC075 * 00 70W NVMVM1MC105 * 00 100W HIE (MH) NVMVM1MC155 * 00 150W NVMVM1MC255 * 00 250W † Rated Ambient °C 40 50 55 40 50 55 40 50 55 40 50 55 40 50 55 40 50 55 40 50 55 40 50 55 Lamp With G34 Holder Globe Only T4 E27 T4 T4 T4 E40 T4 T4 T4 E40 T3 T3 T3 E40 T3 T3 T4 E27 T4 T4 T4 E27 T4 T4 T4 E27 T3 T3 T3 E40 T3 T3 With G251 Globe Only T4 T4 T4 T4 T4 T3 T3 T3 T3 T3 T3 T3 T4 T4 T4 T4 T4 T3 T3 T3 T3 T3 T2 T2 With G34 Globe and Reflector T4 T4 T4 T4 T4 T4 T3 T3 T3 T3 T2 T2 T4 T4 T4 T4 T4 T4 T3 T3 T3 T3 T2 T2 With G251 Globe and Reflector T4 T4 T4 T4 T3 T3 T3 T3 T3 T2 T2 T2 T4 T4 T4 T4 T3 T3 T3 T3 T3 T2 T2 T2 DUST (Class II. Zone 21) Ex t IIIC T. NVMV 250W . These numbers are the maximum surface temperature of the luminaire.. Zone 2) Ex nR II T.. NVMV 70W . – Shown with M20 Ceiling Mount. Note: T3 – maximum surface temperature 200°C T4 – maximum surface temperature 135°C For example: atmospheres that contain gasoline and have an ignition temperature of 536°C.. 50 Hz. small housing /RD739 Dome reflector . NVMV Series S 1M C 07 5 P Guard Wattage Entry Lamp Type Voltage Mounting O O /OPTION Standard Body Options EXAMPLE OF COMPLETED PART NUMBER . order ceiling mount with pendant bracket accessory . Wire the luminaire. select ordering options from tables below and display them in the following order.SMALL BODY: NVMVS1MC075P00 NVMV S 1M C 07 5 P 0 Series Lamp Entry Mounting* Wattage Voltage Guard Body 1M=M20 C=Ceiling W=Wall 2M=M25 J=Stanchion 3M=M32 1 1N= ⁄2” NPT 2N=3⁄4” NPT 3N=1” NPT 5N=1 1⁄2” NPT (For Stanchion) 07=70W 10=100W 15=150W 25=250W NVMV S= Luminaire HSE/ IEC Gear HST (HPS) M=HIE (MH) 0 3=220V/50Hz O=without Guard G34 globe O=Small O=Standard body 5=230V/50Hz P=G251 Globe with P22 alum.small housing /RA70 30° angle reflector .large housing /S890 Champ Quick-Clip Step 1. With one hand on your ladder for safety. simply swing the housing closed until the Quick-Clip attaches to the cover.Ex-Protected Luminaires for IEC and ATEX Applications ORDERING INFORMATION Ordering Example: to complete part number.LARGE BODY: NVMVS1MC255PL0 NVMV S 1M C 25 5 P L Series Lamp Entry Mounting* Wattage Voltage Guard Body NVMV S= Luminaire HSE/ IEC Gear HST (HPS) M=HIE (MH) 1M=M20 C=Ceiling 25=250W 3=220V/50Hz O=without Guard G303 globe 2M=M25 W=Wall 40=400W 5=230V/50Hz P=G303 Globe with P33 SS guard 3M=M32 J=Stanchion 6=240V/50Hz 1N=1⁄2” NPT 4=220V/60Hz 7=230V/60Hz 2N=3⁄4” NPT 3N=1” NPT 5N=1 1⁄2” NPT (For Stanchion) *For pendant mounting.Champ® NVMV Series .large housing /RA739 30° angle reflector . With both hands free. Step 3. CHAMP® QUICK-CLIP 1-2-3 OPTIONS AND ACCESSORIES 6 /IR Instant restrike (100W HPS & 150W HPS) (alternative solution to dual arc lamps) /RD70 Dome reflector .please consult factory. effortlessly tighten the screw. Step 2. 0 L=Large O=Standard body . guard 6=240V/50Hz S=G251 Globe with P22 SS304 guard 4=220V/60Hz 7=230V/60Hz EXAMPLE OF COMPLETED PART NUMBER . order ceiling mount and bracket NAPM (0.5 1/2” NPT 3/4” NPT 1” NPT (1.5 M20 x 1. Components can be ordered separately or as replacement parts.89kg) Stanchion (J) NJ5N 1-1/2”” NPT (1.5 1/2” NPT 3/4” NPT 1” NPT (1.60kg) NTWM20 NTWM25 NTWM32 NTW1N NTW2N NTW3N M20 x 1.order ceiling mount and bracket NAPM Reflector RD70 Reflector RA70 (0.60kg) (0.88kg) Ballast Housing Figure 1 Globe G303 Guard P33 Stainless Steel (1.LUMINAIRE BREAKDOWN INTO COMPONENT PARTS Choose component parts below based on ordering information on page 6.5 M20 x 1.32kg) NVMV 250W .80kg) Note: for pendant mount installation .35kg) (1.5 M20 x 1.49kg) (0.29kg) Note: for pendant mount installation .250W Ceiling (C) NCM20 NCM25 NCM32 NC1N NC2N NC3N Wall (W) M20 x 1.5 M20 x 1.60kg) NTWM20 NTWM25 NTWM32 NTW1N NTW2N NTW3N M20 x 1.5 1/2” NPT 3/4” NPT 1” NPT (1.5 M20 x 1.79kg) 7 .56kg) (0.45kg) Reflector RD739 Reflector RA739 (0.5 M20 x 1. NVMV 70W .400W Ceiling (C) NCM20 NCM25 NCM32 NC1N NC2N NC3N Wall (W) M20 x 1.89kg) Stanchion (J) NJ5N 1-1/2”” NPT (1.50kg) Pendant (See Figure 1) (1.5 1/2” NPT 3/4” NPT 1” NPT (1.5 M20 x 1.5 M20 x 1.60kg) Guard P22 Aluminum Guard P22 Stainless Steel (0.88kg) Ballast Housing Figure 1 Globe G34 Globe G251 (1.50kg) Pendant (See Figure 1) (1. SWB. and lead sheathed cables (with addition of earthing washer) Steel tape armoured (STA) Braided marine shipboard ADE 6F* Armoured gland for use with SWA.Champ® NVMV Series .To view our complete offering of global cable glands for hazardous and industrial environments. SWB. please see Cooper Crouse-Hinds Global Cable Gland Solutions catalog) To terminate electrical wiring and cords. Note . braided marine shipboard. STA.Ex-Protected Luminaires for IEC and ATEX Applications CABLING OPTIONS (for additional cable gland options. STA. and braided marine shipboard cables Lead sheathed *Example shown with SWB cable. use cable glands wiring method example below: Correctly selected cable gland must: 1) Mate correctly with type of cable used 2) Mate correctly with outside diameter of cable used 3) Be suitable with area classifications 4) Be ATEX certified 5) Be IP66 rated 6) Have a male end thread that mates correctly with cover thread Refer to thread sizes in ordering table on page 6 CABLE EXAMPLES CABLE GLAND EXAMPLES Non-armoured ADE 1F Non-armoured gland for use with non-armoured cable Steel wire armoured (SWA) Steel wire braided (SWB) ADE 4F* Armoured gland for use with SWA.crouse-hinds.com/cableglands 8 . please visit www. LAMP SELECTION GUIDE Refer to the table below to select catalog number for lamp per lamp manufacturer.70A 0.42A HPS/MH 400W 2.73A 0.81A 2.27A 1. RUNNING CURRENT STARTING CURRENT OPEN CIRCUIT CURRENT FITTING TYPE AND WATTAGE 220V 50HZ 220V 60HZ 230V 50HZ 230V 60HZ 240V 50HZ 220V 50HZ 220V 60HZ 230V 50HZ 230V 60HZ 240V 50HZ 220V 50HZ 220V 60HZ 230V 50HZ 230V 60HZ 240V 50HZ HPS/MH 70W 0.58A 0.91A 1.86A 0.79A 1.70A 0.21A 3.91A 1.90A 2.71A 0.42A 0.03A 1.95A HPS/MH 150W 0.31A 1.18A 1.86A 0.30A 1.56A 0.04A 2.36A 1.57A 1.42A HPS/MH 250W 1.40A 0.14A 2.95A HPS/MH 100W 0.97A 1.88A 1.09A 0.82A 0.50A 0.04A 0.73A 0.87A 1.36A 1.57A 1.40A 0.25A 2.04A 0.11A 3.95A 1.04A 1.00A 1.82A 0.06A 1.53A 0.39A 0. MANUFACTURER WATTAGE LAMP TYPE LAMP BASE 70W HSE/HST (HPS) E27 100W HSE/HST (HPS) E40 150W HSE/HST (HPS) E40 250W HSE/HST (HPS) E40 400W HSE/HST (HPS) E40 70W HIE (MH) E27 100W HIE (MH) E27 150W HIE (MH) E27 250W HIE (MH) E40 400W HIE (MH) E40 GE LAMP OSRAM LAMP LU70/90/T/27 LU70/90/D/27 LU70/90/XO/T/27 LU100/100/MO/T/40 LU100/100/D/40 LU100/100/XO/T/40 LU150/100/T/40 LU150/100/D/40 LU150/150/XO/T/40 LU250/T/40 LU250/D/40 LU250/XO/T/40 LU400/T/40 LU400/D/40 LU400/XO/T/40 ARC70/E/U/740/E27 CMH70/TT/UVC/830/E27 CMH70/E/UVC/830/E27/C ARC100/E/U/740/E27 CMH100/E/UVC/I/830/E27/C ARC150/E/U/740/E27 CMH150/TT/UVC/830/E40 ARC250/T/U/740/E40 ARC400/T/U/740/E40 PHILIPS LAMP NAV-T 70 NAV-E 70 NAV-T 70 SUPER 4Y NAV-T 100 SUPER 4Y NAV-E 100 SUPER 4Y SON70WES SONT70WES SONPLUS70WES SONT100WES SONPLUS100WGES NAV-T 150 NAV-E 150 NAV-T 150 SUPER 4Y NAV-E 150 SUPER 4Y NAV-T 250 NAV-E 250 NAV-T 250 SUPER 4Y NAV-E 250 SUPER 4Y NAV-T 400 NAV-E 400 NAV-T 400 SUPER 4Y NAV-E 400 SUPER 4Y HQI-E 70/NDL SON150WGES SONT150WES SONPLUS150WGES SON250WGES SONT250WGES SONPLUS250WGES SON400WGES SONT400WGES SONPLUS400WGES MH70WES HQI-E 100/NDL MH100WES HQI-E150/NDL MH150WES HQI-E 250/D HQI-T-250/D HQI-E 400/D HQI-T 400/N HPIPLUS250WBUGES HPITPLUS250WGES HPIPLUS400WBUGES HPITPLUS400WGES CIRCUIT SIZING Refer to the table below for line currents that will assist in sizing of the circuit branch.64A 1.08A 1.09A 0.53A 0.97A 1.64A 1.50A 0.15A 2.23A 3.31A 1.36A 1.00A 1.08A 1.58A 0.98A 9 .54A 0.07A 2.09A 2.31A 1.50A 0.36A 1.42A 0.57A 0.87A 1.98A 3. 250W) 8 94.0kg) 25° 94.60kg.0.0kg) Pendant (7. RA739 .Ex-Protected Luminaires for IEC and ATEX Applications DIMENSIONS NVMV 70W .Champ® NVMV Series .5 118 276 NVMV 250W .0kg) Wall (21.5 ø 146mm ø 133mm RA70 and RA739 (Small & Large Housing) ø 254mm REFLECTOR DIMENSIONS RD739 (for 250W .250W Ceiling (7.79kg) .56kg) ø 429mm (RA70 .1kg) 2 MT G S LOT S 8mm W IDT H 276 25° 94.400W Ceiling (21.5 4- m 29m ø4 ø 429mm ø 429mm 30°angle (0.7kg) 295 448 424 493 402 355 428 300 Stanchion (8.400W) RD70 (for 70W .60kg) 10 (0.4kg) 519 615 609 300 Stanchion (21.0.6kg) Wall (8.5 4- 8 2 M TG SLO TS 8m m wid th 94.4kg) 355 295 678 632 Pendant (21. . . In the past. walls. contact your Cooper Crouse-Hinds sales representative or contact one of our Lighting Layout Specialists directly: . please log onto www. . Europe. It will also provide detail point-by-point calculations and statistical analysis. . LUXICON® 2. Our light fittings are manufactured to the highest standards and will provide years of reliable service and performance under the harshest conditions. . and Middle East Regions.crouse-hinds. .
[email protected]). Point-by-point light calculation in plan view .com and go to Services and Support > Photometric Information or contact Bob Wisniewski (e-mail: Bob.For Asia Pacific Region. Calculations shown with light fitting placement Illuminance rendering CONTACT US: For complete IES files and additional wattages. LIGHTING LAYOUT SERVICES Need help with a more complex lighting design or analysis? Then take advantage of our free lighting design service using AGi32® software. . engineers had to calculate lighting layouts and design using complex mathematical formulas – also known as the “Lumen Method” and “Point-By-Point” Method. . there are software programs that can easily run these calculations very quickly. Our lighting designers can provide you with lighting layouts for more complex projects that will interface with the latest version of AutoCAD drawings and will provide a more detailed lighting analysis.com).Wisniewski@cooperindustries. .5. . Our latest version. . Lighting layouts. . You can also add in objects that will account for light inference caused by equipment. analysis and designs from Cooper Crouse-Hinds deliver a real competitive advantage. . LIGHTING SOFTWARE Cooper Crouse-Hinds’ LUXICON® software program makes it very easy to perform lighting calculations and professional quality designs. . Today. 11 . contact Pauline Yang (e-mail: Pauline. .Yang@cooperindustries. To order a copy of Cooper Crouse-Hinds’ LUXICON® software or to take advantage of this service. is distributed free of charge and includes a tutorial to introduce users to its operation and several “Wizards” that will assist in a step-by-step process to create your own lighting design. .25. . analysis and designs from Cooper CrouseHinds deliver a real competitive advantage. and other obstructions in the work area. .For North and South America. For over 100 years Cooper Crouse-Hinds has been providing hazardous area lighting solutions. contact Bob Wisniewski (e-mail: Bob.com). .LIGHTING APPLICATION AND DESIGN Lighting layouts. 11 0.41 0.17 0.18 0.45 0.26 0.2% 80% LIGHT OUTPUT UP: 4.com).22 0.09 0.28 0.30 0.17 0.24 0.30 0.12 0.27 0.29 0.21 0.18 0.05 0.48 0.28 0.34 0.33 0.07 0.11 0.26 0.25 0.13 0.19 0.42 0.09 0.14 0.12 0.32 0.21 0.73 0.31 0.27 0. please log onto www.17 0.21 0.40 0.65 0.22 0.19 0.47 0.17 0.19 0.12 0.47 0.38 0.13 0.37 0.07 0.25 0.19 0.06 0.09 0.33 0.40 0.19 0.11 0.08 .58 0.09 0.28 0.20 0.11 0.44 0.14 0.53 0.32 0.47 0.27 0.43 0.20 0.11 0.58 0.60 0.30 0.21 0.18 0.19 0.60 0.29 0.15 0.56 0.6% LIGHT OUTPUT DOWN: 44.08 LAMP: 400W HSE Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 30% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% LAMP: 400W HSE NVMV 400 WATT HSE .42 0.11 0.51 0.25 0.27 0.14 0.28 0.49 0.20 0.24 0.16 0.16 0.53 0.60 0.28 0.36 0.26 0.21 0.10 0.32 0.20 0.51 0.18 0.16 0.22 0.34 0.23 0.51 0.40 0.53 0.0 -60 54.14 0.11 0.10 0.24 0.16 0.12 0.25 0.19 0.44 0.30 0.46 0.17 0.47 0.23 0.26 0.10 0.26 0.18 0.20 0.65 0.16 0.14 0.28 0.17 0.18 0.39 0.11 0.36 0.40 0.12 0.32 0.36 0.27 0.35 0.09 0.34 0.73 0.14 0.24 0.12 0.31 0.09 0.13 0.16 0.45 0.23 0.77 0.12 0.5% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 20% 20% RCR: Room Cavity Ratio 20% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.30 0.17 0.20 0.16 0.41 0.0 0 30 60 UNIT:cd/klm C0 /180 C90 /270 LAMP: 400W HSE Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 NVMV 400 WATT HSE .33 0.19 0.23 0.19 0.15 0.61 0.34 0.52 0.13 0.12 0.22 0.30 0.25 0.09 0.13 0.15 0.30 0.36 0.17 0.26 0.11 0.12 0.46 0.16 0.15 0.0 -30 90.25 0.15 0.22 0.13 0.20 0.18 0.21 0.31 0.17 0.26 0.09 0.24 0.15 0.11 0.22 0.17 0.26 0.14 0.10 0.40 0.44 0.22 0.54 0.12 0.GLOBE AND GUARD ONLY LUMINOUS INTENSITY DISTRIBUTION DIAGRAM -/+180 -150 150 -120 120 0.19 0.0% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 20% 20% RCR: Room Cavity Ratio 20% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.09 0.22 0.73 0.38 0.36 0.25 0.9% LIGHT OUTPUT DOWN: 44.14 0.31 0.37 0.09 0.13 0.18 0.24 0.59 0.51 0.27 0.12 0.77 0.11 0.17 0.17 0.32 0.10 0.15 0.13 0.16 0.58 0.0 -90 90 18.58 0.34 0.27 0.18 0.16 0.44 0.22 0.57 0.58 0.15 0.16 0.22 0.14 0.22 0.13 0.13 0.17 0.21 0.49 0.34 0.35 0.20 0.24 0.09 0.08 0.39 0.16 0.Champ® NVMV Series .14 0.12 0.65 0.22 0.28 0.54 0.23 0.22 0.26 0.10 0.42 0.37 0.12 0.13 0.21 0.20 0.15 0.29 0.44 0.09 0.12 0.17 0.29 0.13 0.20 0.18 0.14 0.25 0.16 0.16 0.22 0.19 0.20 0.25 0.19 0.15 0.17 0.13 0.24 0.11 0.14 0.60 0.09 0.51 0.33 0.10 0.15 0.27 0.50 0.37 0.16 0.35 0.15 0.44 0.26 0.05 80% LIGHT OUTPUT UP: 1.30 0.16 0.24 0.11 0.13 0.09 0.18 0.18 0.12 0.18 0.49 0.crouse-hinds.11 0.25 0.50 0.23 0.13 0.35 0.15 0.06 0.59 0.19 0.39 0.23 0.15 0.0 36.14 0.12 0.31 0.33 0.19 0.08 0.15 0.10 0.19 0.30 0.10 0.14 0.33 0.42 0.41 0.22 0.21 0.25 0.54 0.21 0.18 0.13 0.09 0.47 0.31 0.38 0.47 0.16 0.14 0.11 0.38 0.23 0.10 0.20 0. NVMV 400 WATT HSE .16 0.39 0.18 0.44 0.23 0.34 0.18 0.17 0.15 0.14 0.36 0.35 0.21 0.29 0.17 0.50 0.31 0.10 0.25 0.46 0.21 0.12 0.13 0.16 0.18 0.37
[email protected] 0.19 0.59 0.18 0.39 0.49 0.31 0.23 0.12 0.25 0.26 0.17 0.07 0.6% LIGHT OUTPUT DOWN: 39.15 0.50 0.14 0.42 0.21 0.22 0.33 0.18 0.GLOBE AND DOME REFLECTOR LUMINOUS INTENSITY DISTRIBUTION DIAGRAM -/+180 -150 150 -120 120 0 -90 90 30 60 -60 90 120 -30 150 0 30 60 UNIT:cd/klm C0 /180 C90 /270 -/+180 -150 150 -120 120 0 -90 90 30 60 -60 90 120 -30 12 150 0 30 60 UNIT:cd/klm C0 /180 C90 /270 70% 50% Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 20% 20% RCR: Room Cavity Ratio 20% 10% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.22 0.15 0.10 0.0 72.16 0.24 0.41 0.27 0.36 0.41 0.50 0.17 0.13 0.44 0.com and go to Services and Support > Photometric Information or contact Bob Wisniewski (e-mail: Bob.23 0.10 0.31 0.GLOBE AND 30° ANGLE REFLECTOR LUMINOUS INTENSITY DISTRIBUTION DIAGRAM 80% LIGHT OUTPUT UP: 21.37 0.18 0.17 0.60 0.42 0.15 0.36 0.18 0.13 0.11 0.13 0.42 0.56 0.08 0.60 0.14 0.14 0.46 0.10 0.19 0.21 0.08 0.11 0.37 0.11 0.27 0.10 0.35 0.11 0.42 0.37 0.30 0.18 0.16 0.26 0.28 0.20 0.14 0.12 0.27 0.18 0.29 0.30 0.15 0.17 0.13 0.16 0.22 0.51 0.20 0.25 0.56 0.22 0.16 0.51 0.12 0.56 0.13 0.19 0.58 0.20 0.47 0.09 0.31 0.22 0.13 0.15 0.22 0.13 0.28 0.15 0.31 0.53 0.11 0.34 0.77 0.09 0.Ex-Protected Luminaires for IEC and ATEX Applications PHOTOMETRY: LARGE HOUSING For complete IES files and additional wattages. 09 0.23 0.25 0.20 0.17 0.52 0.11 0.19 0.75 0.23 0.24 0.16 0.18 0.41 0.11 0.13 0.9% LIGHT OUTPUT DOWN: 44.19 0.25 0.59 0.39 0.12 0.46 0.12 0.59 0.36 0.70 0.21 0.20 0.53 0.14 0.10 0.43 0.14 0.21 0.39 0.46 0.14 0.75 0.15 0.11 0.08 0.10 0.36 0.32 0.15 0.08 0.17 0.48 0.20 0.25 0.55 0.10 0. NVMV 250 WATT HSE .16 0.18 0.55 0.09 0.17 0.30 0.11 0.0 72.13 0.39 0.26 0.24 0.37 0.26 0.09 0.16 0.com and go to Services and Support > Photometric Information or contact Bob Wisniewski (e-mail: Bob.16 0.38 0.20 0.39 0.52 0.41 0.64 0.14 0.PHOTOMETRY: LARGE HOUSING For complete IES files and additional wattages.05 0.44 0.11 0.14 0.28 0.18 0.14 0.37 0.42 0.35 0.59 0.15 0.30 0.21 0.60 0.10 0.25 0.12 0.34 0.10 0.60 0.62 0.22 0.18 0.32 0.21 0.35 0.34 0.20 0.09 0.16 0.19 0.18 0.16 0.29 0.24 0.com).0% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 20% 20% RCR: Room Cavity Ratio 20% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0. please log onto www.31 0.17 0.10 0.06 0.30 0.12 0.14 0.29 0.13 0.18 0.03 80% LIGHT OUTPUT UP: 1.30 0.07 0.11 0.14 0.11 0.18 0.25 0.28 0.11 0.11 0.23 0.48 0.23 0.0 300 60 54.15 0.38 0.51 0.17 0.21 0.08 0.43 0.52 0.15 0.19 0.18 0.17 0.61 0.48 0.19 0.10 0.09 0.22 0.32 0.14 0.36 0.12 0.38 0.30 0.13 0.28 0.64 0.35 0.09 0.26 0.17 0.70 0.10 0.07 13 .20 0.28 0.11 0.53 0.17 0.40 0.55 0.14
[email protected] 30 UNIT:cd/klm C0 /180 C90 /270 LAMP: 250W HSE Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 NVMV 250 WATT HSE .18 0.14 0.16 0.60 0.18 0.16 0.14 0.70 0.10 0.21 0.28 0.50 0.16 0.10 0.38 0.32 0.25 0.51 0.07 0.33 0.20 0.13 0.53 0.23 0.34 0.14 0.56 0.09 0.11 0.19 0.56 0.09 0.20 0.59 0.21 0.20 0.46 0.09 0.15 0.17 0.49 0.10 0.24 0.27 0.20 0.18 0.22 0.07 0.14 0.23 0.23 0.44 0.12 0.32 0.19 0.44 0.45 0.16 0.05 0.12 0.48 0.59 0.37 0.15 0.16 0.43 0.20 0.25 0.18 0.24 0.28 0.23 0.11 0.28 0.47 0.28 0.13 0.19 0.17 0.47 0.23 0.13 0.07 0.30 0.32 0.16 0.16 0.47 0.09 0.26 0.GLOBE AND DOME REFLECTOR LUMINOUS INTENSITY DISTRIBUTION DIAGRAM 180 210 150 240 120 0 270 90 30 60 300 90 120 330 150 30 60 UNIT:cd/klm C0 /180 C90 /270 180 210 150 240 120 0 270 90 30 60 300 90 120 330 150 30 60 UNIT:cd/klm C0 /180 C90 /270 70% 50% Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 20% 20% RCR: Room Cavity Ratio 20% 10% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.10 0.45 0.14 0.13 0.27 0.27 0.22 0.15 0.23 0.12 0.11 0.10 0.09 0.48 0.23 0.13 0.12 0.09 0.12 0.41 0.52 0.10 0.44 0.75 0.13 0.18 0.40 0.6% LIGHT OUTPUT DOWN: 39.28 0.17 0.13 0.16 0.14 0.55 0.34 0.15 0.5% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 20% 20% RCR: Room Cavity Ratio 20% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.19 0.19 0.40 0.17 0.41 0.12 0.61 0.12 0.32 0.43 0.11 0.15 0.GLOBE AND GUARD ONLY LUMINOUS INTENSITY DISTRIBUTION DIAGRAM 180 210 150 240 120 0.46 0.27 0.51 0.28 0.21 0.61 0.25 0.33 0.32 0.14 0.6% LIGHT OUTPUT DOWN: 44.30 0.GLOBE AND 30° ANGLE REFLECTOR LUMINOUS INTENSITY DISTRIBUTION DIAGRAM 80% LIGHT OUTPUT UP: 21.45 0.43 0.22 0.12 0.62 0.31 0.20 0.30 0.18 0.22 0.24 0.0 36.36 0.40 0.28 0.16 0.08 0.24 0.51 0.19 0.19 0.26 0.17 0.27 0.10 0.0 270 90 18.59 0.16 0.28 0.42 0.18 0.15 0.19 0.05 0.22 0.16 0.35 0.42 0.26 0.23 0.25 0.34 0.15 0.34 0.21 0.48 0.08 0.55 0.19 0.17 0.25 0.20 0.26 0.21 0.30 0.12 0.20 0.11 0.28 0.20 0.33 0.16 0.36 0.12 0.13 0.38 0.13 0.56 0.19 0.36 0.33 0.21 0.17 0.26 0.38 0.13 0.12 0.27 0.22 0.11 0.27 0.51 0.17 0.23 0.17 0.13 0.37 0.18 0.22 0.13 0.16 0.15 0.17 0.53 0.35 0.64 0.15 0.62 0.18 0.22 0.21 0.13 0.44 0.13 0.42 0.11 0.28 0.27 0.18 0.04 0.16 0.32 0.23 0.09 0.14 0.16 0.15 0.59 0.33 0.32 0.22 0.10 0.21 0.46 0.40 0.04 0.17 0.13 0.19 0.10 0.14 0.14 0.26 0.22 0.08 0.22 0.19 0.08 LAMP: 250W HSE Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 30% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% LAMP: 250W HSE NVMV 250 WATT HSE .crouse-hinds.51 0.09 0.39 0.0 330 90.12 0.28 0.21 0.23 0.21 0.16 0.44 0.35 0.18 0.40 0.23 0.33 0.16 0.14 0.31 0.08 0.32 0.12 0.24 0.16 0.24 0.15 0.32 0.29 0.28 0.13 0.25 0.24 0.12 0.17 0.29 0.30 0.25 0.44 0.14 0.13 0.42 0.34 0.18 0.27 0.06 0.15 0.22 0.18 0.12 0.16 0.19 0.30 0.06 0.2% 80% LIGHT OUTPUT UP: 4.11 0.20 0.12 0.38 0.50 0.11 0.20 0.16 0.12 0.26 0.35 0.15 0.25 0.26 0.15 0. 18 0.48 0.18 0.GLOBE AND GUARD ONLY LUMINOUS INTENSITY DISTRIBUTION DIAGRAM -/+180 -150 150 -120 120 0 -90 90 20 40 -60 -30 60 60 80 UNIT:cd/klm C0 /180 C90 /270 100 0 30 LAMP: 150W HSE Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 NVMV 150 WATT HSE .34 0.35 0.30 0.40 0.42 0.13 0.32 0.29 0.28 0.49 0.37 0.73 0.16 0.28 0.20 0.43 0.23 0.30 0.12 0.22 0.28 0.26 0.30 0.44 0.13 0.24 0.41 0.36 0.08 0.59 0.09 0.49 0.26 0.com and go to Services and Support > Photometric Information or contact Bob Wisniewski (e-mail: Bob.45 0.13 0.14 0.32 0.21 0.26 0.17 0.17 0.66 0.23 0.50 0.32 0.89 0.77 0.43 0.30 0.44 0.19 0.20 0.13 0.16 0.15 0.15 0.44 0.70 0.27 0.43 0.14 0.38 0.29 0.28 0.95 0.18 0.34 0.13 0.76 0.17 0.19 0.58 0.07 0.22 0.56 0.51 0.34 0.28 0.59 0.25 0.24 0.28 0.16 0.66 0.18 0.19 0.53 0.30 0.53 0.16 0.22 0.09 0.21 0.57 0.42 0.14 0.20 0.18 0.44 0.25 0.31 0.12 0.76 0.44 0.68 0.22 0.59 0.10 0.16 0.18 0.15 0.73 0.51 0.36 0.20 0.12 0.55 0.67 0.45 0.27 0.14 0.36 0.14 0.46 0.22 0.23 0.23 0.20 0.10 0.27 0.24 0.17 0.31 0.77 0.21 0.14 0.52 0.56 0.42 0.70 0.35 0.24 0.66 0.15 0.14 0.28 0.13 0.54 0.71 0.13 0. please log onto www.31 0.53 0.22 0.27 0.66 0.22 0.21 0.30 0.21 0.15 0.33 0.21 0.05 0.56 0.21 0.42 0.33 0.27 0.83 0.27 0.20 0.16 0.36 0.66 0.48 0.41 0.77 0.12 0.17 0.34 0.06 0.52 0.60 0.44 0.63 0.29 0.42 0.62 0.65 0.81 0.64 0.39 0.26 0.11 0.40 0.36 0.57 0.48 0.20 0.17 0.47 0.17 0.30 0.28 0.24 0.55 0.18 0.19 0.21 0.21 0.81 0.84 0.24 0.24 0.23 0.50 0.11 0.31 0.23 0.6% LIGHT OUTPUT DOWN: 64.47 0.31 0.25 0.35 0.52 0.11 0.22 0.61 0.05 80% LIGHT OUTPUT UP: 2.13 0.59 0.13 0.37 0.25 0.18 0.76 0.38 0.GLOBE AND DOME REFLECTOR LUMINOUS INTENSITY DISTRIBUTION DIAGRAM -/+180 -150 150 -120 120 0 -90 90 30 60 -60 60 90 120 -30 150 0 30 UNIT:cd/klm C0 /180 C90 /270 -/+180 -150 150 -120 120 0 -90 90 40 80 -60 -30 14 120 60 160 UNIT:cd/klm C0 /180 C90 /270 200 0 30 80% 70% 50% Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 20% 20% RCR: Room Cavity Ratio 20% 10% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.07 0.13 0.61 0.16 0.39 0.19 0.17 0.23 0.25 0.22 0.35 0.41 0.24 0.32 0.25 0.27 0.27 0.46 0.19 0.23 0.32 0.36 0.24 0.47 0.12 0.19 0.19 0.28 0.63 0.17 0.com).34 0.34 0.29 0.0% LIGHT OUTPUT DOWN: 51.36 0.17 0.38 0.56 0.46 0.42 0.50 0.15 0.38 0.23 0.31 0.64 0.52 0.37 0.20 0.69 0.15 0.30 0.26 0.20 0.23 0.25 0.13 0.10 0.55 0.25 0.12 0.18 0.26 0.19 0.22 0.14 0.14 0.35 0.81 0.48 0.33 0.59 0.50 0.24 0.19 0.34 0.24 0.73 0.23 0.21 0.26 0.53 0.15 0.21 0.16 0.29 0.36 0.24 0.41 0.26 0.Ex-Protected Luminaires for IEC and ATEX Applications PHOTOMETRY: SMALL HOUSING For complete IES files and additional wattages.71 0.89 0.GLOBE AND 30° ANGLE REFLECTOR LUMINOUS INTENSITY DISTRIBUTION DIAGRAM LIGHT OUTPUT UP: 36.17 0.26 0.30 0.38 0.37 0.17 0.49 0.17 0.81 0.26 0.17 0.30 0.49 0.81 0.65 0.70 0.4% 80% LIGHT OUTPUT UP: 7.1% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 20% 20% RCR: Room Cavity Ratio 20% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.95 0.21 0.31 0.14 0.18 0.17 0.27 0.42 0.53 0.32 0.13 0.39 0.70 0.70 0.25 0.23 0. NVMV 150 WATT HSE .28 0.30 0.19 0.43 0.32 0.21 0.17 0.19 0.17 0.22 0.40 0.32 0.25 0.32 0.39 0.15 0.83 0.33 0.38 0.14 0.66 0.77 0.07 0.65 0.14 0.21 0.49 0.22 0.58 0.19 0.62 0.39 0.19 0.Champ® NVMV Series .44 0.17 0.17 0.61 0.21 0.46 0.68 0.65 0.31 0.18 0.43 0.35 0.66 0.38 0.71 0.63 0.22 0.19 0.13 0.21 0.24 0.77 0.58 0.15 0.16 0.44 0.4% LIGHT OUTPUT DOWN: 68.40 0.39 0.26 0.35 0.19 0.09 0.27 0.43 0.29 0.37 0.25 0.22 0.15 0.27 0.30 0.39 0.11 LAMP: 150W HSE Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 30% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% LAMP: 150W HSE NVMV 150 WATT HSE .26 0.39 0.19 0.13 0.13 0.81 0.23 0.51 0.31 0.36 0.37 0.31 0.33 0.17 0.29 0.84 0.34 0.25 0.24 0.33 0.19 0.89 0.77 0.83 0.45 0.33 0.17 0.46 0.26 0.46 0.19 0.30 0.52 0.33 0.30 0.15 0.26 0.25 0.26 0.38 0.58 0.23 0.09 0.60 0.21
[email protected] 0.48 0.56 0.16 0.70 0.84 0.76 0.49 0.16 0.51 0.25 0.32 0.41 0.28 0.25 0.37 0.15 0.22 0.28 0.3% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 20% 20% RCR: Room Cavity Ratio 20% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.14 0.27 0.95 0.23 0.crouse-hinds.17 0.36 0.21 0.20 0.22 0.11 .16 0.56 0.12 0.38 0.49 0.20 0.26 0.21 0.56 0.25 0.17 0.54 0.37 0.31 0.28 0.23 0. 74 0.29 0.15 0.14 0.14 0.12 0.17 0.GLOBE AND DOME REFLECTOR LUMINOUS INTENSITY DISTRIBUTION DIAGRAM -/+180 -150 150 -120 120 0 -90 90 60 120 -60 180 240 -30 300 0 30 60 UNIT:cd/klm C0 /180 C90 /270 -/+180 -150 150 -120 120 0 -90 90 60 120 -60 180 240 -30 300 0 30 60 UNIT:cd/klm C0 /180 C90 /270 70% 50% Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 20% 20% RCR: Room Cavity Ratio 20% 10% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.24 0.27 0.30 0.25 0.19 0.12 0.27 0.25 0.28 0.48 0.51 0.16 0.11 0.24 0.42 0.55 0.33 0.49 0.27 0.42 0.21 0.22 0.20 0.85 0.14 0.08 0.11 0.44 0.11 0.62 0.11 0.33 0.3% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 20% 20% RCR: Room Cavity Ratio 20% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.23 0.11 0.17 0.37 0.63 0.27 0.17 0.20 0.24 0.32 0.61 0.66 0.36 0.17 0.35 0.com).16 0.69 0.37 0.17 0.28 0.GLOBE AND 30° ANGLE REFLECTOR LUMINOUS INTENSITY DISTRIBUTION DIAGRAM 80% LIGHT OUTPUT UP: 36.12 0.26 0.13 150W HIE Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 30% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 150W HIE NVMV 150 WATT HIE .25 0.16 0.14 0.25 0.18 0.16 0.39 0.46 0.26 0.28 0.53 0.17 0.14 0.27 0.39 0.16 0.18 0.38 0.16 0.26 0.85 0.22 0.38 0.25 0.28 0.43 0.10 0.31 0.18 0.16 0.61 0.21 0.49 0.37 0.15 0.41 0.22 0.26 0.22 0.39 0.27 0.22 0.13 0.08 0.31 0.12 0.60 0.48 0.27 0.42 0.77 0.45 0.66 0.43 0.69 0.28 0.20 0.32 0.10 0.51 0.21 0.32 0.63 0.22 0.89 0.15 0.10 0.41 0.27 0.15 0.37 0.51 0.14 0.26 0.15 0.34 0.58 0.37 0.34 0.33 0.59 0.17 0.10 0.13 0.59 0.74 0.18 0.41 0.23 0.43 0.43 0.72 0.17 0.52 0.09 0.55 0.14 0.07 15 .34 0.48 0.20 0.21 0.09 0.4% 80% LIGHT OUTPUT UP: 7.11 0.23 0. NVMV 150 WATT HIE .23 0.32 0.37 0.44 0.16 0.15 0.11 0.17 0.23 0.GLOBE AND GUARD ONLY LUMINOUS INTENSITY DISTRIBUTION DIAGRAM -/+180 -150 150 -120 120 0 -90 90 30 60 -60 90 120 -30 150 0 30 60 UNIT:cd/klm C0 /180 C90 /270 150W HIE Ceiling Wall Floor RCR 0 1 2 3 4 5 6 7 8 9 10 NVMV 150 WATT HIE .crouse-hinds.60 0.13 0.08 0.11 0.30 0.25 0.23 0.19 0.42 0.24 0.21 0.16 0.39 0.15 0.28 0.24 0.18 0.17 0.51 0.25 0.57 0.14 0.36 0.19 0.20 0.48 0.45 0.59 0.21 0.19 0.14 0.24 0.07 0.17 0.34 0.22 0.23 0.25 0.17 0.38 0.30 0.28 0.57 0.25 0.13 0.22 0.38 0.28 0.77 0.16 0.22 0.31 0.30 0.46 0.06 80% LIGHT OUTPUT UP: 2.30 0.09 0.66 0.17 0.18 0.48 0.20 0.42 0.30 0.34 0.22 0.22 0.23 0.14 0.38 0.08 0.20 0.15 0.19 0.19 0.17 0.19 0.30 0.09 0.72 0.15 0.11 0.14 0.31 0.77 0.32 0.20 0.72 0.30 0.15 0.70 0.23 0.20 0.22 0.40 0.28 0.20 0.34 0.18 0.42 0.6% LIGHT OUTPUT DOWN: 64.26 0.19 0.12 0.1% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 20% 20% RCR: Room Cavity Ratio 20% 20% 20% 0 0 0 Coefficients of Utilization (CU) 0.12 0.14 0.44 0.14
[email protected] 0.48 0.61 0.33 0.24 0.31 0.0% LIGHT OUTPUT DOWN: 51.43 0.24 0.70 0.16 0.30 0.22 0.63 0.21 0.14 0.41 0.48 0.25 0.23 0.40 0.18 0.46 0.10 0.14 0.18 0.44 0.55 0.46 0.47 0.28 0.27 0.12 0.51 0.27 0.19 0.35 0.35 0.27 0.26 0.51 0.21 0.36 0.74 0.18 0.38 0.23 0.35 0.33 0.30 0.48 0.38 0.21 0.33 0.23 0.16 0.4% LIGHT OUTPUT DOWN: 68.29 0. please log onto www.69 0.17 0.24 0.25 0.28 0.58 0.13 0.19 0.17 0.15 0.44 0.22 0.64 0.26 0.31 0.54 0.89 0.29 0.14 0.61 0.11 0.32 0.31 0.17 0.59 0.36 0.24 0.20 0.59 0.35 0.38 0.19 0.18 0.19 0.50 0.12 0.69 0.12 0.63 0.28 0.12 0.61 0.34 0.23 0.49 0.23 0.10 0.13 0.32 0.12 0.12 0.40 0.20 0.45 0.21 0.59 0.57 0.09 0.55 0.24 0.18 0.14 0.23 0.63 0.25 0.16 0.21 0.11 0.18 0.15 0.19 0.52 0.66 0.16 0.29 0.12 0.22 0.14 0.40 0.56 0.17 0.28 0.09 0.22 0.42 0.10 0.85 0.26 0.31 0.com and go to Services and Support > Photometric Information or contact Bob Wisniewski (e-mail: Bob.55 0.19 0.21 0.21 0.16 0.48 0.53 0.16 0.18 0.53 0.11 0.18 0.35 0.47 0.32 0.63 0.21 0.16 0.43 0.PHOTOMETRY: SMALL HOUSING For complete IES files and additional wattages.32 0.32 0.14 0.22 0.24 0.12 0.27 0.59 0.55 0.20 0.61 0.35 0.20 0.29 0.16 0.19 0.18 0.89 0.18 0.27 0.19 0.41 0.22 0.55 0.19 0.31 0.32 0.34 0.50 0.37 0.39 0.39 0.63 0.28 0.49 0.32 0.27 0.25 0.39 0.62 0.15 0.70 0.26 0.34 0.42 0.24 0.47 0.15 0.21 0.13 0.14 0.25 0.27 0.15 0.24 0.13 0.43 0.11 0.37 0.22 0.25 0.11 0.48 0.20 0.46 0.15 0.09 0.18 0.30 0.18 0.31 0.36 0.65 0.23 0.21 0.28 0.16 0.49 0.39 0.14 0.56 0. 52-555-804-4000 FAX: 52-555-804-4020 mxmercadotecnia@cooperindustries. Ltd.com India: Cooper India Pvt. 86-21-2899-3600 FAX: 86-21-2899-4055 cchsales@cooperindustries. (Global Headquarters): Cooper Crouse-Hinds Wolf & Seventh North Streets Syracuse.For more information: If further assistance is required.com Europe (Germany): Cooper Crouse-Hinds GmbH 49 (0) 6271 806-500 49 (0) 6271 806-476 info-ex@ceag. ©2009 Cooper Industries. or Customer Service Department.V. 5800 Houston.com 4966-0909 Printed in USA .S. Ltd.cooperindustries.com China: Cooper Crouse-Hinds Pte. 91-124-4683888 FAX: 91-124-4683899 cchindia@cooperindustries. U.customerctr@cooperindustries. Inc.com Canada: Cooper Crouse-Hinds Canada Toll Free: 800-265-0502 FAX: (800) 263-9504 FAX Orders only: (866) 653-0645 Mexico/Latin America/Caribbean: Cooper Crouse-Hinds. 65-6297-4849 FAX: 65-6297-4819
[email protected]. TX 77002-1001 P: 713-209-8400 www. 600 Travis. Ltd.com Australia: Cooper Electrical Australia 61-2-8787-2777 FAX: 61-2-9609-2342 CEASales@cooperindustries. NY 13221 (866) 764-5454 FAX: (315) 477-5179 FAX Orders Only: (866) 653-0640 crouse. Sales Office. please contact an authorized Cooper Crouse-Hinds Distributor.com www. de C. S.com Korea: Cooper Crouse-Hinds Korea 82-2-3484-6783 82-2-3484-6778
[email protected] Middle East (Dubai): Cooper Crouse-Hinds LLC 971 4 4272500 FAX: 971 4 4298521 Singapore: Cooper Crouse-Hinds Pte.A.com Cooper Crouse-Hinds is a registered trademark of Cooper Industries. Ltd. Ste. Your Authorized Cooper Crouse-Hinds Distributor is: Cooper Industries. Inc.