Nemo Outdoor Training

March 30, 2018 | Author: dwahjoedi3984 | Category: File Transfer Protocol, Digital Technology, Digital & Social Media, Computing, Technology


Comments



Description

Nemo Outdoor User TrainingNemo User Training Course Contents • Nemo Outdoor_Indoor Basic Installation • Hardware Configuration • Nemo Outdoor Measurement Configuration • Introduction to Graphical User Interface • Nemo Outdoor Playback & File Formats Nemo Outdoor_Indoor Installation Nemo Outdoor_Indoor License Option Basic SW Installation Copy Protection • Nemo Outdoor uses either software or hardware protection. (Indoor and Outdoor measurement are restricted by dongle options) • Various available options are configured with each copy protection module. Nemo Outdoor/Indoor Installation Installation: • You need to have local Administrator rights to install Nemo Outdoor • Run the Nemo Outdoor setup.exe file and follow the instructions. Current Nemo Outdoor SW is 4.20.73 Check the latest versions of Nemo software from our web pages at (www.nemotechnologies.com) Valid to users with Technical Support Agreement only. • Install DKU 2 cable driver. • Restart laptop HARDWARE SETUP . Testing Concept – Voice Call • The voice testing environment consists of – Nemo Outdoor compatible test measurement mobiles – Laptop/Tablet PC with Nemo Outdoor installed – Necessary connecting cables – GPS receiver for Outdoor measurement – (optional) fast frequency scanner. . Testing Concept – PS Data Call • The PS data testing environment consists of Nemo Outdoor Application Server(e. POP3 server. HTTP server. or WAP server) . FTP server. SMTP server.g. Nemo Outdoor Measurement Configuration . • Manual mode is based on the user establishing a data transfer connection or making voice calls. . quickly and easily built with the Script Editor. Scripts can be saved and edited. when user wants to make a single continuous data transfer session or a voice call to monitor the resource allocation and cell reselection performance. This mode requires the user to control phones with Nemo Outdoor. Script files can be.Manual / Automated Mode • Nemo Outdoor supports manual and automated mode. The user should NOT use the mobile keyboard to establish voice calls or data calls. - • Automated mode is based on scripts that establish data transfer connections or voice calls on behalf of the user and can repeat the same or different sessions for a defined period of time. This mode is useful. Introduction to Graphical User Interface Device Info Configuration: Device Info: • ( )view disp parameters • ( )define displayed parameters • ( )configure notifications • ( )control phone • ( )configure measurement parameters . Data calls etc.Measurement Properties • Measurement properties for Voice Calls. Need to be defined before the actual measurement . like Ping address and size of Ping data . • PDP Context Properties defines used APN for Packet data connection • Data Protocol defines whether FTP or UDP is used for data transfer • ICMP Ping Properties defines Ping settings. etc. (Press “Properties”) • Voice Number defines the phone number to which voice calls will be made. user name and password for service. • Data Number defines the phone number for data calls.Manual Measurement Configuration • Information on this tab should be filled in when doing Manual Measurement. Manual Measurement Control • Measurement can be done from Mobile’s Control Panel or from Measurement menu by selecting the appropriate mobile . Automatic Measurement • Measurements can be automatically repeated by predefined number of times • Voice calls. etc. MMS. FTP. can be included in automatic measurement sequence • Add / Modify / Delete / Move up / Move down / Append script / Repeat script value/ New /Open / Save / Save As. PDP activation. launch of external application.. Web browsing. .. SMS. data calls. Ping sessions. attach. the call attempt is considered to be failed. After that. .Voice Call Script Configuration • Script Editor/ Add / Voice Call • Voice Call Properties – Number defines the number to be called – Call Duration determines the time that the call lasts in seconds – Call Attempt Timeout value determines the maximum duration of the call attempt. PS Script Configuration Application Testing • Access Point Name defines the APN used • User Name/Password etc. Depend on operator’s settings . the client always opens those new connections so the firewall does not block the connection. and in that case the data transfer would fail. • Password: password for the FTP server.PS Script Configuration • Host Name: IP address of the FTP server used. Send – uploading • Remote File: File @ FTP Server • Local File: File @ Testing laptop . With passive mode. • Passive Mode: Some firewalls may be configured to refuse any incoming connection requests. • Username: username for the FTP server. • Direction: Receive – downloading. 203.PS Script Configuration • URL: IP address of the test file that will be downloaded.58.125.120/1000kb.htm • Local File: File @ Testing laptop . For example. Script Configuration • Editing PS Script – Ping Test – The ICMP (Internet Control Message Protocol) Ping functionality allows you to perform ping measurements simultaneously with FTP testing and data transfers . . • Improved wait function allows waiting for notifications during script measurements. • Option to use measurement settings configured for manual testing during script measurements.Script Enhancements • Possibility to synchronize scripts repeats between devices for benchmarking measurements. a sound (.Event Trigger Notifications •By clicking the Notifications sheet. you can access the Notifications dialog box •Select the Events that you would like to be notified of and also select whether the notification will be a textual note in the Output window. or a bitmap •Own notifications can be created for different situations.wav file). like bad quality example below. in Configuration tool . • User configurable event trigger .User Defined Event Trigger Configuration I • Static triggers • Static triggers are made available in Nemo Outdoor by default and can collect statistics. User Defined Event Trigger Configuration II • Bitmap image Audio Wave Notification . Event Trigger Configuration • Event bitmap displayed in map window • Event bitmap displayed in line graph • (1.) Textual Notification displayed in the Output window • (2.) Sound Notification . Real-time monitoring during measurement . Real-time monitoring during measurement . Introduction to Nemo Outdoor Graphical User Interface . Introduction to Graphical User Interface . Introduction to Graphical User Interface Script Status window Output window Status bar . Introduction to Graphical User Interface Windows: Graphs Line Graphs allow the user to accurately observe the measurement information. • zoom • thresholds • scale • selectable parameters & values • selectable layers & values • average value presentation • displaying events & notifications . Workspace and Hardware Configuration • By saving the workspace.hwc file: • All information defined in the Measurement Properties Window . the information related to device(s) is saved to the . different views can be saved to a .gst file) • By saving the hardware configuration file.wor file. The following views are saved to the file: • Device Information Window views • Grid and Graph views • Color Set and Parameter selected in the Map Window (Map layers must be saved to MapInfo . Introduction to Graphical User Interface Windows: Graphs Line graph Bar graph . Introduction to Graphical User Interface Windows: Graphs Scatter plot Scanning results . parameters. Double-click on an event to view more information about that particular event. . It is also possible to highlight certain events with color to improve the clarity of the results presented. and statistics to be displayed in the grid table.Introduction to Graphical User Interface Windows: Grids The user can easily select the events. Introduction to Graphical User Interface Windows: Grids Parameters Events . Introduction to Graphical User Interface Windows: Grids Layer3 Statistics Decoded Layer3 . Introduction to Graphical User Interface Textual Windows: Grids Statistics Decoded Layer3 Events Parameters Layer3 Table Graphical Windows: Graphs Scatter plot Line graph Scanning Plots Bar graph . tif formats. . .jpg.bmp. .tab. .Nemo Indoor & Floor plan • Nemo Indoor supports indoor floor plan in . Nemo Indoor & Floor plan • During measurement. . markers( ) need to be inserted in order to plot route on floor plan. Nemo Indoor & Floor plan • Indoor floor plan properties . Nemo Outdoor and MS BTS File . Multiple Real-time Route Coloring • New multi route feature allows users to compare easily measurements from different terminals on the same map or to correlate different parameters from the same terminal. . • A line from the test vehicle to the serving and neighboring BTS can be drawn. Playback in Nemo Outdoor The Play button starts the playback The Pause button pauses the playback The Stop button stops the playback Add Marker Add Textual Note Playback Speed . Files Used by Nemo Outdoor . ftn… Workspace files . . .ft1.dt1. fs1.wor Hardware configuration files .nbf MAP files MapInfo vector and raster maps Result files .Files Used by Nemo Outdoor BTS files .dt2.dt3.hwc Script files .dt4 . .bts.fs1. ft2. . fsn… .nsf . Nemo Outdoor Measurement File • With Call mode measurements.DT1 file is produced. *.FS file is produced. • With Frequency/Pilot Scan (Separate Scanner) measurements . • Open ASCII non-proprietary file format • Easy to view and use . *. LLC and RRC messages • Geographical coordinates and time • Call events and handover events • Location update events • Channel information • Other information . layer 2.Nemo Outdoor Measurement File Contents • Field strength results of the serving and neighbouring cells • Quality class values • Mobile output power level • Layer 3. RLC/MAC. 2004 : 0.12 : : T260 : 11:47:41 #ID Id tag for simultaneous measurement files #AG External antenna gain (dBi) #BF BTS filename #CF Call list filename #CL External cable loss #CM Call mode #HV Handler version #MF Map filename #MT Mobile type #NN Network name : {342E0B9C-E2B5-495e-97AC-87D2B710A166} #NT Network type #PN Test call phone number #SW Device software version #HW Device hardware version GAA 0.7f.00 : : d:\Nemo Tools\deactivate.827 8 LUA 0.827 : GSM 900/GSM 1800 : : af.01.827 GAC 0.00 : Originate : 4.000000 0.000000 0.000000 0 0 0 0 0 11:47:42.000000 0 0 0 0 0 11:47:42.22 ff ver 1.72 28.cb : 4C7 .01.000000 0 0 0 0 0 11:47:42.12.nsf : 0.000000 0.Example of Nemo Outdoor Measurement File header *** Nemo Outdoor 4. Questions? . THANK YOU! .
Copyright © 2024 DOKUMEN.SITE Inc.