MX FMZ 4100 GAB36S.pdf

March 24, 2018 | Author: Narendra Reddy Bhuma | Category: Modularity, Reliability Engineering, User Interface, Sensor, Digital Technology


Comments



Description

FIRE DETECTION SYSTEMSFIRE DETECTION CONTROL PANEL FMZ 4100 GAB36S Safe for certain. Product Use Your advantages The FMZ 4100 GAB36S is a versatile fire detection and extinguishing control panel for analog addressable (MxLoop®) and conventional detectors. Due to its high flexibility with redundant processor system it is the solution for all needs in small and medium sites. The compact Minimax FMZ 4100 GAB36S fire detection and extinguishing control panel offers a flexible range of applications in One of the few panels in the market which combine both analog and conventional detectors with automatic extinguishing control and monitoring. Any modular expansion card of the FMZ 4100 series for all type of detectors as well as modules for monitoring and control of all kind of extinguishing systems can be used in order to fit specific site requirements. Detectors can be connected on up to 6 loops or 12 conventional lines. For extinguishing devices there are up to 12 superviced control lines. Thus enabling the realization of even extensive multi-area extinguishing systems. Ease of operation is ensured trough a menue-driven user-interface. An illuminated large full-graphic LCD, LED indicators and plain texts provide clear, easy understandable information. - Administration buildings Hotels Industrial plants Electronic data processing and other high value articles For both fire detection and automatic extinguishing control. A redundant processor-system on different levels provide optimal reliability. Expensive interface systems are not longer necessary, consequently leading to significant cost savings. Scaleable for all requirements. Configurable hard- and software enables in each case a tailor-made fire protection solution. Cost-effective through analog addressable detector loop (MxLoop®) and less complex wiring installation. Reliable operation with secure data communication between control panel and all loop devices. Easy to realize single- and multiarea extinguishing systems Excellent solution in even highly complex alarm organisations. Networking of up to 32 panels in the full redundant wiring loop MxNet. The whole range of Minimax detectors can be connected, including industrial types, air aspiration and intrinsically safe detectors. Multi-lingual operation system for international applications. S 89412 Model Certified acc. The control panel.de ★ Nr.03/HMB Printed in Germany A special feature of all Minimax control panels is the ability to easily combine the fire detection functions with the control and monitoring of extinguishing systems. extinguishing system released. KG Industriestrasse 10-12 D-23840 Bad Oldesloe Germany Phone: +49 45 31/8 03-0 Fax: +49 45 31/8 03-2 48 E-mail: info@minimax. with addressable detector loop technology or with a combination of both. Technical data FMZ 4100 GAB36S Power supply 230 V/115 V. fire brigade called 30 W / 60 VA Subject to technical alterations Minimax GmbH & Co. +10 %.6 (W x H x D) cm VdS G200019 kg 600 x 557 x 243 Interfaces Main relay Contact capacity Public alarm.de www. The Minimax FMZ 4100 GAB36S is capable to control and monitor 6 extinguishing areas. 50 Hz /60 Hz. remote control between all integrated panels and cross panel cause-and-effect alarm operation. it can be configured to the specific needs of any objects. . key depot. –15 % Emergency power supply 24 V DC (2 x12 V) Maintenance-free batteries Housing design 19 wall cabinet. can be used only as fire detection panel with conventional technology. 12 HE IP rating IP54 Temperature Rel.minimax.Function Building management system FMZ 4100 GAB32 Mimic panel MxNet Remote operation and messaging FMZ 4100 GAB6 FMZ 4100 GAB36S Public alarm Alarm elements Conventional line Spark extinguishing system Automatic fire detector Automatic fire detectors Automatic fire detector Extinguishing system control DMX 50 MxLoop® DMX 50 Loop coupler LKX 50H Monitoring module SUX 50/SUX 50H The Minimax FMZ 4100 GAB36S was designed both for the use as fire detection control panel and as extinguishing control panel. for example. main fault. Up to 600 loop devices can be connected to all of the control panel loops. The network allows system-wide alarm reporting. 12 superviced control lines 72 relay with free contacts Panel networking. humidity °C % – 5 to +40 < 93 Approvals Dimensions Color Weight RAL 7035 25. The system's modularity allows the combination of various components. to ISO 9001 PB14Fe_01/ 11. OC oputputs for: Pre-alarm. This considerably reduces costs. manual-push-button pressed.12. The redundant loop bus enables networking of up to 32 panels. 2 serial data ports Log printer Main fire.03 / 3.
Copyright © 2024 DOKUMEN.SITE Inc.