Mwm Gas Engine Tcg2020 En

March 28, 2018 | Author: Pankaj Kamble | Category: Biogas, Propulsion, Engines, Energy Conversion, Internal Combustion Engine


Comments



Description

. . . . 320 17.560 2.500 1. cosphi = 1 for 50 Hz.6 kW 1.5 17.177 1.710 Height 3) Dry weight genset -1 mm 2.210 2.1 53.430 5.1 18.6 40.6 18.6 kW 1.8 70. 4) According to ISO 3046/1 at voltage = 0.9 43.6 87. 2) Optimized efficiency version.8 9.579 1.200 1.8 43.8 9.6 43. cosphi = 1 for 50 Hz.2 Thermal output 5) ±8 % 1) Version optimized for standalone operation and load compensation.000 Mean effective pressure bar 18.810 1.2 43.4 18.5 Speed min 1.9 Thermal efficiency 6) % 43.8 44.8 Length 3) mm 4. 5) Cooling of the exhaust gases to 120 °C for natural gas and 150 °C for biogas.1 18.3 45.210 2.200 11.7 Thermal efficiency 4) % 47.4 kV.7 86.977 Electrical efficiency 4) % 40.8 85.200 1.0 40.9 86.3 Total efficiency 6) % 85.0 45.Technical data 50 Hz Engine type TCG 2020 V12 K1 1) V12 K 1) V12 2) V16 K 1) V16 2) V20 2) Bore/stroke mm 170/195 170/195 170/195 170/195 170/195 170/195 Displacement dm3 53.700 11.8 9.500 1. rest N2) Minimum heating value (LHV) Hu = 5.430 6.810 1.900 V16 2) V20 2) Natural gas applications NOX ≤ 500 mg/mn3 Dry exhaust manifolds Engine type TCG 2020 V12 K1 1) V12 K 1) V12 2) V16 K 1) Electrical power 4) kW 1.9 43. 3) Transport dimensions for gensets.0 41. The information given in the offer is decisive.210 2.500 1.675 1.210 2.4 18.190 1.810 1.210 2. and a methane number of MN 80 (TCG 2020) or MN 70 (TCG 2020K). 6) According to ISO 3046/1 at voltage = 0.200 Width 3) mm 1.0 kWh/mn3 Dry exhaust manifolds Engine type TCG 2020 V12 2) V16 2) V20 2) Electrical power 6) kW 1. components set up separately must be taken into consideration.500 Mean piston speed m/s 9.500 1.700 13.500 1.320 13.125 1.0 86.8 88.8 9.000 Mean effective pressure bar 15.0 43.9 Thermal output 5) ±8 % Biogas applications NO X ≤ 500 mg/mn3 Sewage gas (65 % CH4 / 35 % CO2) Biogas (60 % CH4 / 32 % CO2. .4 kV.810 1.660 4.190 kg 11. The values given in this data sheet are for information purposes only and not binding.790 4.500 1.645 2.6 17.1 53.253 1. Data for special gas and dual gas operation on request.7 43.810 1.790 5.000 1.021 Electrical efficiency 6) % 42.2 Total efficiency 4) % 87.5 86.560 2.8 9.1 70.0 86.250 1.7 42. rest N2) Landfill gas (50 % CH4 / 27 % CO2. 8 kW 1.500 1.7 18.48 kV. 2) Optimized efficiency version. and a methane number of MN 80 (TCG 2020) or MN 70 (TCG 2020K).500 1.4 40.2 18.8 9.983 Electrical efficiency 4) % 40.970 6. cosphi = 1 for 60 Hz.3 Total efficiency 6) % 85.850 12.8 9.8 9.2 45.000 Mean effective pressure bar 18. cosphi = 1 for 60 Hz.210 2.8 41.710 Height 3) Dry weight genset -1 mm 2.790 1.8 17.125 1.470 Width 3) mm 1. rest N2) Engine type Minimum heating value (LHV) Hu = 5.6 86. The values given in this data sheet are for information purposes only and not binding.500 Mean piston speed m/s 9.790 1.2 18.6 Thermal output 5) ±8 % Biogas applications NO X ≤ 500 mg/mn3 Sewage gas (65 % CH4 / 35 % CO2) Biogas (60 % CH4 / 32 % CO2.500 1.6 Thermal efficiency 6) % 43.210 2.560 2.4 42.190 kg 12.500 1.8 Length 3) mm 5.258 1.500 1.6 43.850 14. 5) Cooling of the exhaust gases to 120 °C for natural gas and 150 °C for biogas. Data for special gas and dual gas operation on request.850 19.400 Natural gas applications NOX ≤ 500 mg/mn3 Dry exhaust manifolds Engine type TCG 2020 V12 K 1) V12 2) V16 K 1) V16 2) V20 2) Electrical power 4) kW 1.0 kWh/mn3 Dry exhaust manifolds TCG 2020 V12 2) V16 2) V20 2) Electrical power 6) kW 1. The information given in the offer is decisive.Technical data 60 Hz Engine type TCG 2020 V12 K 1) V12 2) V16 K 1) V16 2) V20 2) Bore/stroke mm 170/195 170/195 170/195 170/195 170/195 Displacement dm3 53.4 Thermal efficiency 4) % 45.196 1.640 6.3 86.970 5.8 70.0 43.657 2.589 1.850 14.560 2.261 1.686 1. .790 1.200 1.8 43.200 1.6 43.210 2.2 Total efficiency 4) % 86.7 43.027 Electrical efficiency 6) % 41.8 kW 1.1 70.48 kV.640 7.3 86.7 43.5 Speed min 1.8 9.210 2.7 43.8 88.7 18.3 85. 3) Transport dimensions for gensets. rest N2) Landfill gas (50 % CH4 / 27 % CO2.8 18.7 86.1 53.9 43.000 Mean effective pressure bar 17. components set up separately must be taken into consideration.9 Thermal output 5) ±8 % 1) Version optimized for standalone operation and load compensation. 6) According to ISO 3046/1 at voltage = 0.790 1.6 85. 4) According to ISO 3046/1 at voltage = 0.
Copyright © 2024 DOKUMEN.SITE Inc.