MULTIX SwingErgonomic, reliable, economical Data sheet www.siemens.com/healthcare s 6” / + 19. horizontal and lateral acquisitions. height-adjustable catapult bucky with oscillating grid (wall or floor mounting available). Tube assembly stand Integrated tube assembly stand for vertical. precise reproducibility and short exposure times. standing or recumbent patient with horizontal beam projection.MULTIX Swing Ergonomic. Patients with body height of up to 190 cm (75”) can be conveniently radiographed from head to toe without repositioning (with short tabletop* for smaller rooms: 170 cm / 67”). routine and ER diagnostics – thorax diagnostics MULTIX Swing system consists of a patient table with a floating tabletop.0 cm (± 4. economical MULTIX Swing is a compact. costefficient radiography workplace with a cassette catapult bucky. clinics or radiology departments of hospitals with different types of examinations utilizing conventional acquisition systems. This system is a universal radiographic workplace suitable for private practice. a catapult bucky and an integrated tube support with tube assembly and collimator – to meet all clinical imaging requirements. It is prepared for use with film-cassette or phosphor storage acquisition systems. * Option .7“ / 15.7“). It is especially suited for all acquisitions of skeletal radiography of the recumbent and seated patient: – orthopedic diagnostics An easy-to-use system with many advantages Generator Table High-frequency X-ray generator with multi-pulse waveform for diagnostic acquisition procedures on radiographic workplaces.6”) provides transverse movements of ± 12. Additionally.7”) and longitudinal movements of – 60 cm / + 50 cm (– 23.7”).7“) provides longitudinal movements of – 50 cm / + 40 cm (19.000 lbs). reliable. obese patients are imaged easily. with a table weight capacity of up to 450 kg (1. The optional short tabletop (length: 200 cm / 78. POLYDOROS ITS X-ray generator: Bucky wall stand* For radiography of the seated. The multi-pulse waveform enables high beam quality. oblique. The generator is integrated into the table base to save space. Counterweighted. – trauma. Tabletop The floating tabletop (standard length: 220 cm / 86. Synchronous horizontal movement of the X-ray tube and bucky tray for constant beam centering. . movement arrested by electromagnetic brakes Central beam height 36 cm to 185 cm Rotation of tube around vertical axis ± 90°. movement arrested by electromagnetic brakes Tabletop-to-film distance 7 cm Automatic exposure control standard Bucky wall stand VERTIX Swing (option) Bucky wall unit with height-adjustable catapult bucky cabinet. 5“ x 7“ to 14“ x 17“ Scatter radiation grid Pb 10 : 1. moving grid Travel of bucky – 30 cm / + 20 cm.55 mm Al eq Automatic exposure control standard Column stand 4 Longitudinal travel 123 cm. 40 lines/cm.or right-handed operation of the catapult bucky. transverse: ± 12 cm Max. 200 cm x 80 cm (short tabletop*) Radiation absorption ≤ 0. Vertical movement 152 cm Central beam height 38 cm to 190 cm above floor Cassette sizes 13 cm x 18 cm to 35 cm x 43 cm. Left. focus range 110 cm – 180 cm.6 mm Al eq at 100 kV Tabletop travel longitudinal: – 60 cm / + 50 cm (standard). transparent grid and IONTOMAT three-field chamber.MULTIX Swing Technical Data Radiographic table Radiographic table with floating tabletop.000 lbs) Cassette sizes 13 cm x 18 cm to 35 cm x 43 cm. ± 90° Source-image distance up to 116 cm at table * Option . Table height 75 cm Tabletop dimensions 220 cm x 80 cm (standard). transparent grid and IONTOMAT three-field chamber. ± 90° X-ray tube rotation ± 120°. – 50 cm / + 40 cm (short tabletop*). lock positions: 0°. movement arrested by electromagnetic brakes Vertical travel 149 cm. 5“ x 7“ to 14“ x 17“ Scatter radiation grid in bucky Pb 10 : 1. patient load 450 kg (1. moving grid Front plate-to-film distance < 4. 40 lines/cm. lock positions: 0°. focused at 115 cm.5 cm Radiation absorption ≤ 0. 29 kVA at 480 V with optional pre-transformer* Room height min.5 mAs to 800 mAs 0. 96 kVA (ITS 55) / max. 50/60 Hz with optional pre-transformer* Power consumption max. 440/480 V.6 / 1. 3-phase.5 mAs to 320 mAs Installation data Line connection 3-phase.000 HU (170. 400 V – 15% / + 10%. nominal (IEC 60336) 0. 27 kVA at 440 V with optional pre-transformer*. 51 kVA (ITS 30) Nominal load 25 kVA at 400 V.5 mm Al at 70 kV Generator Generator POLYDOROS ITS 55 POLYDOROS ITS 30 Output (IEC 60601-2-7) 55 kW (550 mA at 100 kV) 30 kW (300 mA at 100 kV) Exposure voltage 40 kV to 133 kV 40 kV to 133 kV Shortest switching time with automatic exposure control 2 ms 1 ms 2 ms 1 ms mAs range 0.2 Anode heat storage capacity 230. 50/60 Hz.X-ray tube assembly X-ray tube OPTIPHOS 135/30/55R Nominal voltage (IEC 60613) 135 kV Nominal output (IEC 60613) 30/55 kW Focal spot. 245 cm Ambient conditions (operation) Temperature range: Relative humidity: Barometric pressure: * Option + 10°C to + 40°C 20% to 75% below dew point 700 hPa to 1060 hPa 5 .000 J) Anode operating frequency 50 Hz / 150 Hz Radiation absorption (IEC 60601-1-3) 2. MULTIX Swing Technical Data Accessories MULTIX Swing • Two handgrips for insertion into the accessory rails of the patient positioning tabletop • An external manual release for exposure • Compression belt* • Lateral cassette holder for lateral acquisitions* • Patient positioning mattress* VERTIX Swing • Lateral handgrips* • Patient stretch grip* • Babix holder* 6 * Option . Floor plan (mm) – examples *1 depending on installation (fix SID) 7 . com/healthcare Siemens AG Wittelsbacherplatz 2 D-80333 Muenchen Germany www.com/healthcare Order No. we recycle certain components.siemens.2008 Siemens AG .The information in this document contains general descriptions of the technical options available and may not always apply in individual cases.siemens. Using the same extensive quality assurance measures as for factory-new components. In the interest of complying with legal requirements concerning the environmental compatibility of our products (protection of natural resources and waste conservation). Siemens reserves the right to modify the design and specifications contained herein without prior notice. Fluoroscopic and Radiographic Systems Siemensstrasse 1 D-91301 Forchheim Germany Telephone +49 9191 18-0 www.com/healthcare Global Siemens Headquarters Global Siemens Healthcare Headquarters Legal Manufacturer Siemens AG Wittelsbacherplatz 2 D-80333 Muenchen Germany Siemens AG Healthcare Sector Henkestrasse 127 D-91052 Erlangen Germany Telephone +49 9131 84-0 www. The required features should therefore be specified in each individual case at completion of contract.siemens. Global Business Unit Address Siemens AG Medical Solutions Angiography. Original images always lose a certain amount of detail when reproduced. A91AX-30001-11T3-7600 | Printed in Germany | AX CRM MC 07083 | © 07. Please contact your local Siemens sales representative for the most current information. we guarantee the quality of these recycled components.
Report "Multix Swing Datasheet"
×
Please fill this form, we will try to respond as soon as possible.
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
Copyright © 2024 DOKUMEN.SITE Inc.