MMM004 en Vacucell

March 29, 2018 | Author: PHAM BAT THONG | Category: Thermostat, Door, Ac Power Plugs And Sockets, Electrical Connector, Vacuum


Comments



Description

Vacuum cabinets line StandardVACUCELL 22, 55, 111 Operating instructions MMM Medcenter Einrichtungen GmbH Producer: MMM Medcenter Einrichtungen GmbH Schulstrasse 29 D – 82 166 Gräfelfing Tel.: +49 89 89 92 26 20 Fax: +49 89 89 92 26 30 VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 1 Contents 6.11.2002 1 GENERALLY.................................................................................................................................. 3 1.1 1.2 2 2.1 2.2 2.3 3 3.1 3.2 3.3 3.3 4 4.1 4.2 4.3 PURPOSE ..................................................................................................................................... 3 USE ............................................................................................................................................. 3 UNPACKING, CHECKING, TRANSPORT AND HANDLING ...................................................................... 3 BEFORE PUTTING INTO OPERATION ................................................................................................ 4 USEFUL SPACE ............................................................................................................................. 5 GENERAL VIEW ............................................................................................................................. 6 CONTROL PANEL IN THE DOOR OF THE BOX .................................................................................... 7 CONTROL PANEL IN THE SUPERSTRUCTURE .................................................................................... 8 MAINS CONNECTION AND CONNECTORS ......................................................................................... 8 IMPORTANT INSTRUCTIONS ...................................................................................................... 3 DESCRIPTION OF THE UNIT ....................................................................................................... 6 FUNCTION AND OPERATION...................................................................................................... 9 SWITCHING ON ............................................................................................................................. 9 SWITCHING OFF .......................................................................................................................... 10 SETTING-UP REQUIRED VALUES OF TEMPERATURE, TIME-DELAYED SWITCHING-OFF, NUMBER OF CYCLES, TIME-DELAYED SWITCHING-ON. ............................................................................................... 10 4.4 USER'S SUPPORTING FUNCTIONS ................................................................................................. 12 4.5 LIST OF THE ERROR MESSAGES ................................................................................................... 12 4.6 PROTOCOL PRINTING .................................................................................................................. 12 4.7 SAFETY THERMOSTAT FUNCTION AND SETTING ............................................................................. 13 4.8 CREATION OF VACUUM IN THE CHAMBER ...................................................................................... 14 4.9 SEALING EXCHANGE AND DOOR SETTING ..................................................................................... 14 5 6 7 8 9 10 11 SPECIFICATIONS OF THE UNIT................................................................................................ 15 5.1 ELECTRIC CONNECTION............................................................................................................... 16 CLEANING ................................................................................................................................... 16 MAINTENANCE ........................................................................................................................... 16 WARRANTY CONDITIONS AND SERVICE ............................................................................... 16 TRANSPORT AND STORAGE.................................................................................................... 17 METHOD OF LIQUIDATION OF THE PACKING AND OF THE DISCARDED UNIT................. 17 OPTIONS...................................................................................................................................... 17 11.1 11.2 11.3 11.4 11.5 COMMUNICATION SW WARMCOMM FOR PC UNDER WINDOWS ................................................. 17 BOX „VACUSTATION“ .............................................................................................................. 18 CHEMICALLY RESISTANT VACUUM PUMP ................................................................................... 18 SEPARATOR AND EMISSION CONDENSER .................................................................................. 18 SYSTEM OF VACUUM CONTROL ................................................................................................ 18 VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 2 V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211 Operating instructions VACUCELL-line Standard Page 3 1 Generally 1.1 Purpose VACUCELL is an electrically heated and evacuated chamber which may be used after evacuation to heat the objects located in it. Evacuated objects are placed on the shelves in the chamber. The unit operates up to the temperature of 200 °C. The temperature course is controlled by modern microprocessor (Fuzzy-logic) with digital display and Pt 100 temperature sensor. This system secures high precision of the temperature regulation and reliability of the tempering process. The unit is designed in accordance with appropriate standards ČSN EN - see 2.2, 5.1 and fulfils requirements of directions EU 89/336/EHS, 73/23/EHS (resp. 93/42/EHS). Made of high-quality materials and using the latest technology. Each piece goes through a careful output checking. 1.2 Use VACUCELL is designed to perform: - vacuum drying of easy oxidable matters with possible displacement of oxygen by inert gas - accelerated drying of form-simple and complicated parts - drying of samples up to constant weight at adjustable temperature and selectable time mode. The unit may be used primarily in the following branches: - biology - cosmetics - pharmaceutics - food industry - chemistry - electric technology - plastics processing - engineering The unit is designed to be used and handled by the persons familiar with dealing with the laboratory equipment and apparatuses. 2 Important instructions 2.1 Unpacking, checking, transport and handling After unpacking please check that the unit and the accessories are complete and undamaged ). Possible damage must be immediately reported to the transporter. When handling - lifting the box, etc - the box must not be lifted using the hand rail or the door! Lift the box using the four hooks that you push into the openings in the side of longitudinal legs of the box. Standard delivery consists of the cabinet and two shelves. (order No.: V459046 - volume 22, V 459047 – volume 55, V 459048 – volume 111), silicon hose 8 x 18 for connection chamber/ vacuum source (order No. 0662132 ). VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 4 2.2 Before putting into operation • Before beginning the work with the unit please read the operating instructions carefully! • • ♦ ♦ The unit is designed to work in interior spaces within the ambient temperatures of 5 °C up to 40 °C, at maximum relative humidity of 80 %. Install the instrument by plugging the power cord to a line voltage socket. Prescribed parameters of the supplies are stated in chapter Electric Connection. In case of temperatures above 100 °C a yellowed stain of the inner chamber walls can occur. This stain is neither the material nor the unit’s defect.. After the first switching-on the heating bodies start to be burnt, which results in a characteristic smell; this smell disappears after several operating cycles. Minimum distance of the unit from the rear and side walls is 100 mm. Do not place inflammable or explosive matters into the unit! Ovens are designed to be operated indoor within ambient temperatures from 5 °C to 40 °C and at maximum relative humidity 80 %. Carrying capacity of the floor during installation of the device must correspond to the weight of the unit itself taking the weight of the maximum charge into consideration (see chapter Parameters of the unit). Goods are only to be put on trays into ovens, never directly on the bottom of the oven ! No inflammable, explosive or toxic materials may be put into ovens! The same applies to materials that could give off such a stuff. The unit is not designed for warming of liquids and does not contain any liquids. In case of any manipulation with the unit, other than its normal use, disconnect it from electric mains by pulling the supply cord from the socket ! When depressing the key the unit is set only in the stand-by mode, but it is not disconnected from electric mains ! • In case the unit is not in use for a longer time period, disconnect it from the mains by the mains switch (position 2 - panel of the upper piece) or by pulling the supply cord from the socket. Protection of the thermal box, its surrounding and of the treated material against inadmissible temperature rise is secured by the protection thermostat The class of protection of the unit is 2 according to the EN 61010-2-010. Check regularly – daily – the function of protection thermostat V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211 • • • • • • • • Operating instructions VACUCELL-line Standard Page 5 • The unit must not be placed on a pad that could cause a danger of fire or smothering in case of falling some hot object out of the cabinet. Maximum permissible load: see chapter Specifications of the unit. Do not put any object on the outer surfaces of the ovens. During the operation of the ovens at high temperatures the maximal permitted temperature of 70 °C can be surpassed on their outer surface (neighbourhood of the chamber sealing, glass door), where a danger of burn can occur. Please pay the highest attention. • • • 2.3 Useful space Useful space is illustrated in Fig.1, where X(H) = 10 % of the interior chamber depth, X(Š) = 10 % of the interior chamber width, X(V)1 is the distance od the lowest shelve from the bottom of interior chamber, X(V)2 is the distance of the top shelve from the top of the interior chamber. Within the space limited by said surfaces (according to the standard DIN 12 880 illustrated by thick lines, thinner lines illustrate the interior walls of the chamber) temperature deviations stated in chapter Specifications of the unit are maintained. ). It means, that over the last upper tray there are the limits from in chapter Specifications of the unit not obligatory. Fig. 1 VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 6 3 Description of the unit 3.1 General view Fig. 2 1 2 3 4 5 6 7 Panel of the regulator Control panel Control panel cover Panel of the superstructure Pt 100 temperature sensor and Safety thermostatsensor Heating bodies Power part 8 9 10 11 12 13 14 15 16 Power supply cord built-in socket for the vacuum pump vacuum fittings inlet to connect the vacuum pump heat resisting glass of the door measuring feedthrough RS-232C connector supply of inert gas to the needle valve ball valve V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211 Operating instructions VACUCELL-line Standard Page 7 3.2 Control panel in the door of the box Fig.3 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Display decimal point - lights (the unit is connected to the mains - stand-by condition) preselected programs indicator lamps- lights: program is active - blinks: program will be active in 5 sec. heating indicator lamp - lights:condition of temperature regulator - heating active switching-on indicator lamp - lights after switching the unit on by the depression of ON/OFF protection thermostat indicator lamp - lights:temperature exceeds the selected setting limit of the protecting thermostat - heating is off/further information see chapter 4.8.Protecting thermostat function and setting-up Setting-up mode activation button setting the value downwards setting the value upwards switch ( ON – switched on, OFF - stand by condition) adjustable protecting thermostat - outer rotary ring button (RESET) to set the protecting thermostat in operation again Indicator lamp: blinks - setting-up mode, lights - active part of the program is time-delayed switching-on Indicator lamp: blinks - setting-up mode, lights - active part of the program is heating upto set temperature Indicator lamp: blinks - setting-up mode, lights - active part of the program is time-delayed switching-off Indicator lamp: blinks - setting-up mode, lights - decrease of temperature after switching-off Indicator lamp: blinks - seting-up mode, lights - active part of the program is infinite stay on set-up temperature Indicator lamps 14-18 blink - mode of number of cycles setting VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 8 3.3 Control panel in the superstructure Fig. 4 1 2 3 mains main switch indicator mains main switch ball valve connecting the chamber and the vacuum pump , in position ON is valve open needle valve to add inert gas or air 5 6 7 vacuometer indicator of the mains switch of built-in socket in the superstructure mains switch of the built-in socket in the superstructure - for the vacuum pump 4 3.3 Mains connection and connectors The mains connecting cord passes through the bush in the left part of the upper piece to the power board, located in the upper piece. In the right part of the upper piece there is a connector RS232 C and a built-in socket for the vacuum pump accessible after lifting off the cover – see figure below. In the right rear part of the upper piece there is an opening, through which the hoses from the pump and with inert gas are connected to the VU. 3 4 mains socket (for the vacuum pump) RS-232C connector to connect the printer V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211 Operating instructions VACUCELL-line Standard Page 9 Interface for protocol printer Fig. 6 Ovens connected by RS-232C connector must meet the regulations and be approved Pin Signal 2 TX 3 RX 5 GND by the testing laboratory. The unit is designed to connect the CITIZEN printer type iDP 3110-24 RF-A vhich may be ordered to be delivered to the unit.. Interface parameters Baud: 9600 Stopbit: 1 Parity: none Databit: 8 4 Function and operation The unit can be set up in some modes according to the required function, in other words its cycle can be modified, as described below. Function of individual control lights and control keys is described in chapter Description of the unit. 4.1 Switching on 1. Green indicator of the mains switch and green indicator in the right lower corner of the display (condition [stand by]) shine after connection to the mains and after switching on the mains switch on the panel of the superstructure.. 2. Depress button indicator lamp above the button, indicator lamp of one of preselected programs and indicator lamp of initial active phase of the program light up; if preset temperature is higher than that in the chamber,the heating indicator lamp lights also - either permanently or intermittently (depending on switched on or switched off heating regulator). 3. The display displays real data relating to active phase of the program. 4. Mains switch to the left of the panel in the superstructure serves to switch on the mains socket of the pump (built-in in the shaft of the superstructure) VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 10 4.2 Switching off Press the key . The display turns off, only the green control light in the lower right corner is on (stand by). Disconnection from the mains is performed by switching off the mains switch, in case of longer setting out of operation or during the repair by pulling the plug of the mains cable from the socket. The total unplugging from mains (in case of a long-term putting out of operation or a maintenance) is achieved by pulling the service cord from a socket – see also chapter Pre-installation. 4.3 Setting-up required values of temperature, time-delayed switching-off, number of cycles, time-delayed switching-on. or . After depressing 1. Set preselection of program 1 or 2 or 3 by means of or the control lamp of further program starts to flicker. This program will be activated within ca. 5 sec, if no other button is depressed during this time. Setting by means of or will cause the stop of the running cycle and starting a new cycle with the preselected parameters. Setting-up cycle begins with setting required temperature, , indicator lamps 15, 16 (Fig.3) begin to flicker, by means of 2. Depress required temperature in °C on the display The lowest adjustable and displayable temperature interval is 1 °C. Indicator lamps of the segments flicker permanently. 3. By depressing set change to the segment of setting the time-delayed switching- off, by means of set required value in hours and minutes from 0 (symbol---) to 99 hrs 59 min on the display, indicator lamps 16, 17 (Fig.4) flicker. 4. By depressing change to the segment of setting the number of cycles and by means of set the number of cycles from 1 up to 255 (more information on the cycles see 4.4) - all indicator lamps flicker during setting up. This function can be used with time-delayed switching-off ≠ 0 only. Set the possibility to select the cycles by means of the user'supporting function. 5. By depressing change to the segment of setting the time-delayed switching- on and by means of set the required value in minutes from 0 up to 99 hrs 59 min, indicator lamp 14 (Fig.3) flickers. 6. Start the program by double depressing (start of the program is announced by an acoustic signal), data on real temperature with time count-down flickers on the display during the phase of time-delayed switching on. The heating is switched on after reaching the time of zero and the display shows the real temperature in the chamber. After reaching the required temperature V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211 Operating instructions VACUCELL-line Standard Page 11 a) in case of setting the time-delayed switching-off, the chamber temperature with the set time count-down begins to flicker on the display b) or in case of unlimited switching-off, the chamber temperature with the rising time flicker on the display. Permanently lighting indicator lamps give information on just active program segment. 7.Individual set values can be checked during the run of the program - by depressing the required value is shown on the display, indicator lamps flicker, by another depressing within 5 seconds you change to the next segment, in this way all settings can be checked successively. Original program continues if you use no control element within 5 seconds. 8. Similarly, during the course of the program, you can change the already set values, when a) after setting the last value - time-delayed switching-on - you wait approximately 5 seconds, the program continues with changed values from the point of interruption b)after setting the value you start the program by double depressing starts with new values from the beginning. 9. Total course of one cycle is illustrated in Fig.7. , the program Fig. 7 Phase 0 a b c function time-delayed switching-on temperature rise time-delayed switching-off temperature drop after switching-off VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 12 4.4 User's supporting functions + Entry the function by simultaneous depressing By means of set on the display a) U1 - setting the period of print of the printer from 0 up to 255 min, enter the setting by means of b) U2 - ON or OFF - permission or prohibition of cycles (for all pre-selections at the same ; a cycle means multiple repetition of time), enter the setting by depressing program with set time-delayed switching-off and switching-on. Leave the setting by depressing and leave the function by depressing . the c) U3 – Prn or PC – data transfer via interface RS 232 either on the printer (Prn) or, in case of using the program DS Com, on the computer (PC); set Prn or PC by means of 4.5 List of the error messages Err 1 - not calibrated (the service engineer performs compensation of measuring conduits of the sensor). Err 2 - free Err 3 - free Err 4 - Err 10 - HW error (report this event to the producer) 4.6 Protocol printing Printing the protocol with the help of CITIZEN printer, type iDP 3110-24 RF-A. By setting the interval of the printer you determine the time intervals in which the actual value of the temperature in the chamber will be printed. Magnitude of this interval is stated in the heading of the excerpt. Interval of the printer can be set on the display within: tmin = 1 minute, tmax = 255 minutes ( 4 hours 15 minutes) by 1 minute. 1. We start from the condition, when the display displays real value of the temperature. Connect the printer to the hot air box by means of the cable with serial connector (RS232C) into the socket for the printer (see Fig.4), the other end of the cable connect to the connector in the rear part of the printer. Connect the printer to the mains by connecting the connector of the adapter AC 230 V, 50 Hz, 0.1 A/DC 7 V,1.6 A into the socket in the rear part of the printer and by pushing the adapter into the mains socket. Switch on the switch on the right side of the printer. Indicator POWER and SEL start shining. The printer is in the ON-LINE mode and it prints in this mode only! If you want to feed the paper, depress the key LF. This may be performed only in the OFF-LINE mode, i.e. after depressing the key SEL, when the indicator SEL stops shining. Re-depress the SEL key to restore the ON-LINE mode, indicator 2. According to par. Setting-up required values of temperature set the required interval upwards or downwards V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211 Operating instructions VACUCELL-line Standard Page 13 3. The printer prints the head containing the type of the unit, set temperature and selected time interval. Values of the following data are printed in one line under this heading: time from starting the program and actual temperature in the chamber. 4. Switching the print off is performed by setting the print interval to 0 (symbol ---). 5. In case of change of set operation conditions of the oven or in case of change of print interval a new heading will be printed (this is not valid when set interval is 0 (symbol---)). 6. If the power supplying the apparatus fails , after the power recovery the printer prints the sign Power recovery! and the actual temperature value. Time intervals start counting immediately after power recovery. After switching-off and switching-on by means of again a new head is printed. 7. If the power supplying the printer fails or the printer is turned off, no message is printed after turning the printer on again or after power recovery . 8. Setting of the DIP / switches of the printer: all four pins are in lower position OFF. 4.7 Safety thermostat function and setting Safety thermostat serves to protect the thermal box, its surrounding and treated material against inadmissible exceeding the set temperature (e.g. it prevents damage or destroying of material samples in case of a damage to the temperature regulator or unintentional setting of higher temperature in the chamber of the unit than respective sample is able to bear). In case of correct setting, the safety thermostatswitches off at approximately by 5 °C up to 10 °C, higher temperature than the temperature set on the regulator of the unit. Setting the thermostat: 1. Press the external rotary ring of the thermostat towards the control panel and with simultaneous slight pressure turn it to the right (clockwise) up to the limit position (maximum). The center with the knob turn together with the external ring. 2. Thermal box is heated up to required operation temperature and approximately 10 minutes at this temperature. left to stabilize for 3. Then turn the ring slightly to the right and depress the key of the thermostat. A slight click is heard and indicator safety thermostat stops shining. If the click is not to be heard and the indicator does not stop shining turn the ring slightly more to the right and depress the key again. Repeat this procedure as long as the indictor stops shining. Only in such case is the thermostat set onto required temperature. If the unit is set to maximum temperature turn the ring to the right to maximum according to item 4. Operation of the unit continues.. NOTICE: Used safety thermostatis of class 2 (according to EN 61010-2-010) - mark TWB. When surpassing set temperature in the chamber, the thermostat switches the heating bodies off and the indicatorsafety thermostat starts shining (the unit does not heat even if the indicator heating shines). Even after the drop of the temperature below set limit of the protection thermostat, heating remains switched off. It is necessary to depress the knob of the safety thermostatto restore the operation. Indicatorsafety thermostat stops shining. VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 14 4.8 Creation of vacuum in the chamber Push the hose from the vacuum pump onto the end of the vacuum piping of the unit (Fig.2, position 11) which is accessible through the side cut-out in the superstructure. Connect the mains cord of the vacuum pump into the socket in the shaft of the superstructure and switch the pump on. Set the ball valve on the front panel of the superstructure into the position VAC ON. Value of vacuum begins to rise on the vacuometer in the front panel after several tens of seconds (the needle valve and the door must be properly closed). 4.9 Sealing exchange and door setting Take the whole sealing off, begin in the middle bottom part. Fix the new sealing on the edge of the chamber, begin in the middle bottom part. Slam the sealing between the chamber and the outer cover. To check up the tighteness place a sheet of paper between the door and the chamber when closing the door. Pull it out slowly, you should feel a stronger resistance. The door is adjustable at four points (see Fig.12): Pins of the lock – on the left front part of the jacket – at the top and at the bottom: these pins can be loosened by means of the lock nut and they can be adjusted forwards/backwards by means of the thread. Door hinge, lower: by loosening the screw M8 at the front on the right side of the foot it is possible to adjust the door forwards/backwards in the horizontal direction. Door hinge, upper 2: after removing the cover of the extension part the screws M8 in the front right corner become accessible. After loosening these screws the position of the door can be adjusted. Adjust the door so that when closed the rubber sealing of the chamber would fit to the sheet of the floating door along the whole perimeter. To check it up place a sheet of paper between the sealing and the metal sheet of the floating door before it is closed, it is possible to take the paper out against a small resistance. V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211 Operating instructions VACUCELL-line Standard Page 15 5 Specifications of the unit Specifications Internal space stainless steel DIN 1.4571 Shelves volume width depths height Shelves guidesimpressions in the chamber side walls number height width × depth width depths height nett brutt Model litres mm mm mm number max. Pieces suppl mm mm max. mm max. mm max. mm kg kg from 5 °C over ambient temp to °C upto ± °C upto ± °C upto ± °C upto ± °C upto ± °C upto ± °C min min min min W W DN mm DN mm Ø mm mbar kW W A V kg kg 22 22 340 260 300 5 2 40 280×236 560 490 700 65 79 200 2 <5 0,4 10 18 0,5 60 80 130 170 150 300 16 40 8 -3 5.10 0,8 5 3,5 230 20 35 55 55 400 320 430 8 2 10 340×296 620 550 830 98 114 200 2 <6 0,4 10 18 0,5 65 85 140 180 260 520 16 40 8 -3 5.10 1,2 5 5,2 230 25 45 111 111 540 410 480 9 2 40 480×386 760 640 880 130 150 200 2 <7 0,4 11 ∗ 1,0 110 130 170 220 370 750 16 40 8 -3 5.10 1,8 5 7,8 230 25 65 Shelves distance Usefull dim.of shelf External dimensions (incl.door and handle) Weight Working temp (regulation start) Temp. deviations acc.to DIN 12 880 Teil 2 from working temp -Al shelvs pressure 5-10 ++ mbar Temp. deviations acc.to DIN 12 880 Teil 2 from working temp-ss shelvs pressure 5-10 ++ mbar Time of rise onto 98 % voltage 230 V – (Al shelvs pressure 5-10 mbar) Time of rise onto 98 % voltage 230 V - (ssteel shelvs, press 5-10 mbar) Heat radiation Vacuum connection spatially at 100 °C spatially at 200 °C timely spatially at 100 °C spatially at 200 °C timely onto temp 100 °C onto temp 200 °C onto temp 100 °C onto temp 200 °C at 100 °C at 200 °C vacuum connection measuring feedthrough needle valve for inert gas or air attainable vacuum max. input input in stand by mode current nominal voltage one shelf totally per unit Electric parameters – mains 50/60 Hz Max.permissible load of the shelves Note: All technical data are related to 22 °C ambient temperature and ± 10 % voltage fluctuations (if not specified otherwise). For other parameters see section Electric connections. ∗ not measured ++ The heat in vacuum is transferred to the goods on the shelves by conduction in the shelves, therefore the mentioned temperature deviations are valid for temperatures on the surface of the shelves, there must be a perfect heat-conducting contact between the temperature sensors and the shelf surface. Goods placed on the shelves must also be in a perfect contact with the shelves, the goods temperature depends especially on their physical properties and on the contact with the shelf. VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 16 5.1 Electric connection TNC or TNS I double insulation (tested by 4 kV voltage) CEE-7/VII, IEC-83/CH, 16 A/250 V min. 10 A IP 20 II in case of pollution degree 2 2xF10 A,1xT400mA (î 5x20 mm) some other according to the customer’s voltage system class of protection against dangerous touch external circuits insulation type of plug of the unit socket protection protection according to EN 60529 overvoltage category according to IEC 664 (EN 61010) used fuses plug CEE-7/VII, IEC-83/CH, 16 A/250 V (event. wish) Recommended cable leading from the switchboard to the socket 3 × 2,5 mm2 Cu. With one-phase units the cable is 3 × 2,5 mm2 Cu. The type of the socket corresponds to the type of the plug. 6 Cleaning Cleaning is to be performed only after cooling the unit down and after disconnection of the mains cord from the mains. Internal walls of the chamber and the surface of the unit is to be cleaned with water and detergent or suitable chemical means, it is necessary to use rags that are not rough and do not release fibres. Abrasive cleaning means are not recommended, they could couse scratching of the metal sheets. In case of contamination of the oven either outside or inside by dangerous material the user is responsible to carry out a proper decontamination of all contaminated surfaces with a suitable and approved disinfecting agent. Before using of any method of cleaning or decontamination different from our recommendations we recommend to verify at the producer the compatibility of the procedure. 7 Maintenance The unit requires no special maintenance. In case of troubles, please, contact the service. 8 Warranty conditions and service MMM guarantees faultless delivery and function within the frame of contract rules and warranty time. Fixed sale and delivery conditions of MMM are valid. MMM assumes no responsibility for the faults or other losses originated due to normal wear, chemical of physical influences, natural disasters, extreme loading, incorrect operation or improper or inadequate use, especialy when not observing the appended operating instructions, in case of incorrect installation, in case of damages originated due to the effect of foreign bodies, as well as in case of faulty or improper maintenance or repair. In the case of sending back to the producer (to repair or exchange at claim), use the original package. In the other case you accept the responsibility for eventuel damage during transport and the producer will exact from you a compensation of necessary coherent repairs. V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211 Operating instructions VACUCELL-line Standard Page 17 For a correct connection to the mains observe the technical data and Operating instructions. Important notice: MMM (producer) is responsible for safety and technical properties of the unit only in case, when the repairs and modifications of the unit are performed by herself or by the organization specifically authorized by her, and when the parts will be during the repair substituted by the spare parts admitted by the producer and spare parts satisfying the quality standard of MMM. MMM recommends the user of the unit to ask the one who carried out the repair for the certificate on the kind and extent of work, if need be with the data concerning the change of nominal data or work extent, date of performance, name of the company and signature. 9 Transport and storage The unit is being prepared for transport by an authorized person (who dismounts the connections). The unit shall be transported in its original package. If you send the device back (for instance to repair or in case of reclamation), use the original package. Otherwise you take responsibility for possible damaging during the transport and producer will claim the costs for appropriate repairing of you. The device shall be stored in the range of temperatures from 0 °C to 40 °C. 10 Method of liquidation of the packing and of the discarded unit a) pallet – liquidation in the refuse incinerating plant b) cardboard - recyclable waste a) discarded unit - liquidation to be done by a company authorized to handle the waste, the unit contains no poisons. 11 Options 11.1 Communication SW DS Com for PC under Windows The software DS Com is designed to record the temperature course in the thermal cabinets. Data obtained during the regulation are displayed in form of a graph (with time on the horizontal axis and obtained data on the vertical axis). The software enables to follow the regulation in real time, to store the regulation course to a file on the disc and to view the already stored files. Operation instructions of this software are delivered together with the installation software, minimal requirements on PC hardware for the program DS Com 2.1 are: • IBM-compatible PC (386 and above) • Operation system Windows 95 and above • 80 MB RAM • one-hour-record of data requires free space of about 60 KB on the hard disc • free serial port VACUCELL_S_en_np_mmm 0211 V 1.04_Blue Line Operating instructions VACUCELL-line Standard Page 18 11.2 Box „Vacustation“ Serves for placing the vacuum pump MZ2C, resp. MD4C (event. another vacuum pump with appropriate dimensions) in the space of the box, the vacuum box Vacucell is placed on top of it. Both elements are screwed together. 11.3 Chemically resistant vacuum pump For instance membrane vacuum pumps MZ2C (suction power cca 1.7 m3/h, achievable vacuum cca 9 mbar) and MD4C (suction power cca 3 m3/h, achievable vacuum cca 2 mbar) are recommended. 11.4 Separator and emission condenser The separator of the gas/steam exhausted from the chamber is placed between the chamber and the pump (the separating has a favourable influence on the power of the vacuum pump), emission condenser with water cooler is placed on the pump outlet and reduces the amount of emissions of the exhausted gas/steam in the outer space. Both parts are made of glass and are fixed on the pump. 11.5 System of vacuum control Consists of the part CVC II and an electromagnetic suction valve. It enables to keep the constant value of vacuum in the chamber and to show the measured values on the display CVC II. CVC II is placed separately outside the box Vacucell and the suction valve is installed in the extension part of Vacucell. V 1.04_Blue Line VACUCELL_S_en_np_mmm 0211
Copyright © 2024 DOKUMEN.SITE Inc.