Mitek Electrodes

March 23, 2018 | Author: Nicușor Anghel | Category: High Voltage Direct Current, Switch, Knee, Shoulder, Electricity


Comments



Description

TROUBLESHOOTINGGUIDE S I N G L E - U S E B I P O L A R G E N E R AT O R E R R O R & F A U LT S Y M B O L S Most technical problems are indicated by either an ERROR or a FAULT symbol that appears in the Generator display window. IN T E G R AT E D H A N D PI EC E An ERROR symbol indicates an accessory malfunction or a Generator component TIP: failure that requires servicing of the equipment. These symbols include a code number to be used by DePuy Mitek technical service to diagnose why the system failed. • Solid one-piece active tip design • An ERROR symbol is displayed as two alternating messages: • Proprietary active/return distance ratio • Large uninhibited suction hole • Atraumatic liquid crystal polymer cowling provides insulation – ERROR XXX REF YYY – INTERNAL FAILURE WARNING: An error symbol indicates an equipment malfunction, which may be hazardous. Disconnect all accessories and switch the Generator off. Switch the Generator back on and if the self-test is completed satisfactorily as evidenced by the “CONNECT CABLE” symbol in the display, the failure occurred in the accessories, which should be discarded and replaced. If the self-test fails, then all functions will be inhibited and no attempt should be made to use the Generator. Contact DePuy Mitek customer service for assistance. A FAULT symbol indicates a transient non-hazardous event and can be corrected by resetting the system. • A FAULT symbol is displayed as two alternating messages: – FAULT XXX REF YYY – TEXTUAL MESSAGE - where TEXTUAL MESSAGE relates to the type of fault NOTE: Remember to take note of the fault code for reporting to customer service before completing the reset. CLEANING NOTE: See User Manual for Generator and Footswitch cleaning instructions. All VAPR Electrodes are single-use only. S H A F T: • High dielectric strength insulation maintains electric activity at tip Software failure CABLE: 100 12 Non volatile memory failure • Integrated power connection with pliable kink-resistant material 100 14 Power generation fault on startup 300 10 Internal overheating (refer to troubleshooting guide in user manual) 300 12 Out of specification input voltage: low 300 13 out of specification input voltage: high 300 14 Accessory fault (refer to trouble shooting guide in user manual) (VAPR II only) 300 16 Temperature control system problem 300 20 Unsupported electrode (VAPR 3 only) 400 10 Footswitch blue pedal stuck 400 11 Footswitch yellow pedal stuck 400 12 Handswitch input fault 400 13 Menu/reset button stuck (VAPR 3 only) 400 14 Electrode identification circuit fault 90º Suction 3.0mm S50 Knee Electrode 50º Suction *** 3.5mm Flexible Side Effect 3.5mm Angled Side Effect, 21º 400 15 Front panel switch fault: yellow up button 400 16 Front panel switch fault: yellow down button 400 17 Front panel switch fault: blue up button 400 18 Front panel switch fault: blue down button 3.5mm Side Effect 3.5mm 90º Hook 2.3mm End Effect 400 19 Front panel switch fault: mode button 400 20 Intermittent activation switch 400 21 Accessory thermistor fault (open) 400 22 Accessory thermistor fault (short) 400 23 Accessory fault (invalid electrode configuration) • Indentation indicates active tip orientation I N T E G R AT E D H A N D P I E C E QUICK REFERENCE GUIDE 227202 227203 227213 227211 227252 DESCRIPTION 10 HANDLE: 227312 227302 227301 227305 REF 100 • “Pin Exposed” plug design for ease and security of connection 225370 227355 FAULT SYMBOL 4mm S90 2.3mm Wedge 2.3mm Wedge Short 2.3mm Side Effect Short 2.3mm Temperature Control End Effect 1-800-382-4682 www.depuymitek.com ©DePuy Mitek, Inc. 2008. All rights reserved. Printed in the USA. P/N 901001. Rev. A 03/08 CORRECTIVE ACTION A Comprehensive Portfolio to Enable Arthroscopic Surgery When a Fault Appears on the Generator 1. Press mode button twice or 2. Depress both footswitches simultaneously and release both footswitches once (VAPR II only) or 3. Press the MENU/RESET button (VAPR 3 only) if error appears on the generator. a. Turn machine off and restart. b. Disconnect electrode and reconnect. If this does not resolve the problem, contact DePuy Mitek customer service at 1-800-382-4682. S H O U L D E R K N E E S M A L L J O I N T S R A D I O F R E Q U E N C Y E L E C T R O D E S 3mm 227213 (Integrated) 2.5mm 225104 (2.3mm 225211 (2.Piece) 45 90 60 Electrode** Size Catalog No.Piece) V2 120 90 180 120 33 Flexible Side Effect 3. • Temperature Control .Piece) V1 5 20 10 50 3 3 Thermal Angled End Effect 3.3mm 225203 (2.5mm 225101 (2.3mm 227252 (Integrated) 2. ***2.Piece) V2 S50 Knee Electrode o 50 Suction o Angled Side Effect. Mode 2-Piece or Integrated Handle Default Maximum ABLATE/ DES/ ABLATE/ DES/ CUT(w) COAG(w) CUT(w) COAG(w) Suction Thermal Flexible Side Effect 3.Piece) V2 Flexible End Effect 3. Avoid costly scope repair and sheath damage.Piece) V2 60 45 90 60 Side Effect Short 2.Piece) V2 3.5mm 225305 (2.0mm 225361 (2.Piece) V1 5-V1 20 10 50 3 3 Thermal Reverse Angled Side 3. ankle.3mm 225252 (2.5mm 225322 (2.3mm 227211 (Integrated) 2.5mm 225302 (2.5mm 225312 (2.Piece) V2 90 60 130 90 SYSTEM FEATURES • Seamless fault safety . 3.3mm 225201 (2.Piece) V2 Angled End Effect 3.3mm 225213 (2-Piece) V2 60 45 90 60 End Effect 2. BIPOLAR BIPOLAR KEY Straight End Effect 90 Hook 60 3 3 Description Small Joint Catalog No.3mm 225202 (2.0mm 225360 (2.Piece) V3 240 120 260 160 3 3 3 3 3 3.Piece) V2 60 45 90 60 3 Wedge Short 2.18mm Most Distal Face.5mm 225112 (2.5mm 227302 (Integrated) 3.Piece) V2 120 90 180 120 33 3.5mm 225301 (2.3mm 3. * Please consult package insert for instructions for use.5mm 225324 (2.5mm 225401 225402 Temperature display and control available only when used with the VAPR II and VAPR 3 electro-surgical generators.5mm 225303 (2.Piece) V2 60 45 90 60 3 Wedge 2.MONOPOLAR Mode 2-Piece or Integrated Handle Default Maximum ABLATE/ DES/ ABLATE/ DES/ CUT(w) COAG(w) CUT(w) COAG(w) Suction S90 90o Suction 4. 3 3 VAPR HARDWARE & ACCESSORIES* Thermal Side Effect 3.5mm 225314 (2.5mm 227305 (Integrated) 3.65mm Insulated Shaft.5mm 225350 (2.5mm 227301 (Integrated) 3.Piece) Temperature Control 1 3 33 N/A 65 40 95 50 ELECTRODES MONOPOLAR ARE 3 3 3 3 3 3 3 3 Side Effect 2.Piece) V3 240 120 260 160 3 3 3 LD Suction (LDS) 4.Piece) BV2 o o 90 Suction BIPOLAR TECHNOLOGY 3.System shuts down when electrode contacts metal. **All VAPR Electrodes are indicated for use in the shoulder. and wrist. The system itself is less complicated and easier to use than monopolar units.5mm 225304 (2. * Knee ELECTRODES Shoulder VAPR 225021 225002 225023 225004 225005 VAPR VAPR VAPR VAPR VAPR Generator – VAPR 3 Handpiece Footswitch Sterilization Tray Power Cord . ALL VAPR V2 120 90 180 120 33 60 130 90 33 60 130 90 33 90 60 130 90 33 120 90 180 120 33 90 90 160 120 200 180 2. Resection of adhesions Chondroplasty Tendon debridement Scar tissue excision 2.3mm 227202 (Integrated) 2.Piece) V1 5-V1 20 10 50 Thermal Flexible End Effect 3. It does not require a grounding pad. Knee Size Shoulder Electrode** Small Joint Description VS.Piece) 5 Labral tear resection Thermal modification Scar tissue excision Chondroplasty ACL debridement Lateral release Meniscectomy Chondroplasty Synovectomy 20 10 50 33 Meniscal cystectomy Plica removal Thermal modification Marking drill holes Synovectomy Cartilage debridement Thermal modification Fracture debridement Suction Sheath Suction Sheath 1 SMALL JOINT KNEE SHOULDER Subacromial decompression Acromioplasty Bursectomy Synovectomy V1 VAPR Suction Sheaths may be used with all non-suction electrodes. elbow.3mm 227203 (Integrated) 2.Piece) V1 5-V1 20 10 50 Bipolar energy has been shown to be safer than monopolar energy as it limits potential damage to alternate sites by containing the energy around the tip.28mm Bend Mid-point.0mm 227355 (Integrated) *** V2 Side Effect 3. knee.5mm 227312 (Integrated) 3. 21 3.available with “Thermal” and “Temperature Control” electrodes. 3.0mm 225370 (Integrated) V3 240 120 260 160 3 LP Suction (LPS) 4.
Copyright © 2024 DOKUMEN.SITE Inc.