MidMeki Manual DSY10003A

April 29, 2018 | Author: Marivee Dollosa | Category: Switch, Usb, Electromagnetic Compatibility, Electrical Connector, X Ray


Comments



Description

Rev Date Issued VersionA 2014-10-20 DSY10003A MIDMEKI MANUAL X-RAY INSPECTION SYSTEM Mekitec Oy Tel. +358 20 741 0990 Teknologiantie 3 Fax +358 20 741 0991 90590 OULU [email protected] Finland http://www.mekitec.com Rev Date Issued Version A 2014-10-20 DSY10003A DECLARATION OF CONFORMITY We hereby certify that the Mekitec Meki X-ray inspection system complies with the following EU electric directives and standards: - Low Voltage Directive (LVD) 2006/95/EC - ElectroMagnetic Compatibility (EMC) directive 2004/108/EC - and the directive 93/68/EEC applying to both above directives and directive 2006/42/EY We hereby certify that Mekitec Meki X-ray inspection system complies with all radiation safety standards, notably the following: - IEC 601-2-28 and UL 2601-1 We hereby certify that Mekitec Meki X-ray inspection system complies with the EU framework regulation 1935/2004 for all food contact materials. The high-voltage (HV) generator satisfies the HV generator standard IEC 601-2-27. The conveyor system complies with the IP65 standard. Manufacturer: Mekitec Oy Contact information: Mekitec Oy Teknologiantie 3 90590 OULU Tel. +358 20 741 0990 Fax +358 20 741 0991 Email: [email protected] Technical Data Collector: Heidi Tikanmäki Tel. +358 40 542 0007 Fax +358 20 741 0991 Email: [email protected] Equipment description: X-ray inspection system for non-destructive testing (NDT) Frame: Stainless steel X-ray source: VJ Technology Corp/USA (Model IXS060BP100P035) Serial Number: S11907-B00065 X-ray detector: Mekitec AQU (Model AQU 0.4-256) Computer: Axiomtek EP850VGGA (CE certified) Display: IEI AFL-12M/T-R-R11 (CE certified) Equipment model: MEKI D4 Serial number: 61144143985 2 Rev Date Issued Version A 2014-10-20 DSY10003A The composition and structure of each unit is entered in our database. The structure of each equipment unit complies with the following harmonised EU standards: LVD EN 60439-1:2000, EN 60493-3:1993+A1:1994+A2:2001 The product is referred to by a structural document, document nr DRR2001A EMC Noise emission: EN 55022:1994 + A1:1995 +A2:1997 (class B), (EN 60555-2:1987) Generic emission immunity standard in residential, commercial and light industry: EN 50082-1:1992 Generic immunity standard in industrial environment: EN 50082-2:1995 The noise does not exceed 70 dB. X-ray inspection system The X-ray source is normally used in medical X-ray inspection systems and therefore satisfies more stringent radiation safety requirements than for industrial environments, namely EMC requirements: IEC 601-1-2 Particular requirements for safety of HV generators: IEC 601-2-27 Particular requirements for X-ray source assemblies: IEC 601-2-28 Inherent filtration: IEC 60522 Standard for x-ray equipment: UL 2601-1 (USA) The compliance of each manufactured equipment unit with the directives and standards are provided by our quality assurance instructions. Place: __________________________________ Date: __________________________________ Name: __________________________________ Title: __________________________________ Signature: __________________________________ 3 Rev Date Issued Version A 2014-10-20 DSY10003A CONTENTS WELCOME��������������������������������������������������������������������������������������������������������������������������������������������������������������� 5 1. SAFETY INSTRUCTIONS������������������������������������������������������������������������������������������������������������������������������������� 5 2. MAIN PARTS OF MIDMEKI�������������������������������������������������������������������������������������������������������������������������������� 6 3. X-RAY SETTINGS������������������������������������������������������������������������������������������������������������������������������������������������ 7 4. WASHING INSTRUCTIONS��������������������������������������������������������������������������������������������������������������������������������� 7 4.1 Opening and washing of system port�������������������������������������������������������������������������������������������������� 7 4.2 Removing the conveyor belt system���������������������������������������������������������������������������������������������������� 8 4.3 Removing the curtain cassette������������������������������������������������������������������������������������������������������������� 8 4.4 Protecting the non waterproof parts��������������������������������������������������������������������������������������������������� 9 4.5 After washing: secure functionality��������������������������������������������������������������������������������������������������� 10 5. MAINTENANCE������������������������������������������������������������������������������������������������������������������������������������������������� 10 5.1 Warnings����������������������������������������������������������������������������������������������������������������������������������������������� 10 5.2 Parts������������������������������������������������������������������������������������������������������������������������������������������������������ 10 5.2.1 X-ray generator �������������������������������������������������������������������������������������������������������������������������������� 10 5.2.2 X-ray camera (AQU) ������������������������������������������������������������������������������������������������������������������������� 11 5.2.3 Conveyor��������������������������������������������������������������������������������������������������������������������������������������������� 11 5.3 Electrical connections�������������������������������������������������������������������������������������������������������������������������� 12 5.3.1 Main switch��������������������������������������������������������������������������������������������������������������������������������������� 12 5.3.2 Power supply������������������������������������������������������������������������������������������������������������������������������������� 12 5.3.3 Safety equipment and safety switches������������������������������������������������������������������������������������������ 12 5.3.4 Control switches�������������������������������������������������������������������������������������������������������������������������������� 13 5.4 Mechanics��������������������������������������������������������������������������������������������������������������������������������������������� 14 5.4.1 Cabinet and radiation shielding������������������������������������������������������������������������������������������������������� 14 5.4.2 Mechanical construction������������������������������������������������������������������������������������������������������������������ 14 5.4.3 USB ports and Ethernet������������������������������������������������������������������������������������������������������������������� 14 5.5 The error messages����������������������������������������������������������������������������������������������������������������������������� 15 5.5.1 X-Ray detector –no response���������������������������������������������������������������������������������������������������������� 15 5.5.2 X-Ray generator –no response�������������������������������������������������������������������������������������������������������� 15 5.5.3 Other error notifications������������������������������������������������������������������������������������������������������������������� 15 5.6 Conveyor belt replacement����������������������������������������������������������������������������������������������������������������� 16 4 Rev Date Issued Version A 2014-10-20 DSY10003A WELCOME This Midmeki Manual will quide you with general 1. Midmeki system information and maintenance of Midmeki system. 2. Safety issues This Manual is original version. 3. Mechanical construction 4. Maintenance of the system The Manual is intended to help users who need to work with: 1. SAFETY INSTRUCTIONS The Meki equipment is composed of electro- Users of the system must comply with the technical products including X-ray source. The following instructions: type of X-ray source is X-ray tube meaning that it is producing radiation only when the X-ray • Never insert any parts of the body into the is switched on. There is a red warning light on system or system port/port extensions when whenever the X-ray is on. X-ray is energized! • Do not attempt to install or use this system if The Mekitec X-ray inspection system was you have not received the appropriate training. developed for food inspection and to fulfill the • Do not touch or make changes to the system’s currently existing health and safety regulations. wiring or safety system. To ensure a safe operation, it is important that the • Do not remove components or curtain unit is correctly installed and operated by properly cassettes if system is running either do not trained personnel. It is extremely important to use the system if cabling is not intact or follow the safety instructions when using the not connected. This may result a risk of high system. voltage and radiation! • Do not use the unit if there are signs of The manufacturer is not responsible for the safety physical damage. of the system if the user has made modifications or repairs to the system without manufacturers permission, if the system has been installed contrary to the manufacturer’s instructions, if the system has been used in violation of the manufacturer’s instructions, if the system has been used for purposes for which it was not intended or if the system has been handled inappropriately. 5 Rev Date Issued Version A 2014-10-20 DSY10003A 2. MAIN PARTS OF MIDMEKI Warning light tower Monitor Main power switch Emergency Stop buttons Switches and control X-ray source buttons (inside the cabin) Conveyor (inside the main Port extensions frame and port exensions) (not in the picture) AQU Camera (inside the conveyor) Stand 6 Rev Date Issued Version A 2014-10-20 DSY10003A 3. X-RAY SETTINGS X-ray values can be adjusted for each product type In the case of thick and/or high density product, to be inspected. The higher/thicker the product higher kV value (50-80kV) is used. In the case of is, the higher kV should be used. For example, thin product, lower kV value (30-50 kV) can be products with high liquid content have a high used. density and need higher kV to get the X-rays pass The mA value can usually be quite close to max trough the product. value, but if scanning speed is low, also lower mA value can be used. The valid X-ray setting values for Midmeki are: ●● 30kV ~ 80kV Beside the properties of the product, also probable ●● 1 mA ~ 5 mA material of foreign object affects to the kV and mA values. In the case of very dense foreign object ●● The limited power value is 200W materials, like steel, high kV value is a good choice. For lower density materials, like glass, a bit lower The kV value determines the penetration of the kV value and higher mA value is better choice. radiation. The higher the kV value is the more penetration power the radiation has. The mA value adjust the amount of the radiation. The higher the mA value is the more radiation (photon flow) is produced by the X-ray source. 4. WASHING INSTRUCTIONS Never wash the system when it is running! Make sure Main power is switched off and the power cable is disconnected before starting the wash! 4.1 Opening and washing of system port Washing of system port: 1. Open the front door. 2. Dismount all non-fixed parts. 7 Rev Date Issued Version A 2014-10-20 DSY10003A 1. Take the conveyor out after dismounting cable connections. 2. Lead curtain cassettes can be pulled out. Pay attention to the safety magnets at inner curtains! 3. Wash the system port regularly with moistened cloth. If the inside of the system gets too dirty, the X-ray performance may decrease or lead to damages of the conveyor belt, which again may cause false rejections. NOTE! Protect all non-waterproof parts before washing direct water! 4.2 Removing the conveyor belt system 1. Switch off the system using the main power switch. 2. Disconnect cables between the system and the conveyor. 3. Slightly raise the conveyor and lift it out of the system. Main power switch Cable connections 4.3 Removing the curtain cassette The four curtain cassettes can be removed easily by lifting them up slightly and pulling them out. The inner cassettes are equipped with safety contact magnets. The X-ray can’t be switched on if they are not in correct positions. 8 Rev Date Issued Version A 2014-10-20 DSY10003A Lead curtain cassettes Safety contacts 4.4 Protecting the non waterproof parts 1. Place a hood over the screen of the system before washing. The display is not waterproof! 2. Wet wipes are recommended when washing the middle section of the system. Using direct water is normally not necessary. 3. Avoid spraying water directly to the bottom panels, where fans and different connectors are located. 9 Rev Date Issued Version A 2014-10-20 DSY10003A 4.5 After washing: secure functionality • After cleaning the system and its • Make sure the curtain cassette is mounted components, mount all parts according to correct and the curtain cassettes with instructions to their original form and place. safety contacts are on the inside. • Make sure all cables are connected properly • Make sure you have needed training and and onto right places. permission to use system before switching it back. 5. MAINTENANCE 5.1 Warnings Radiation hazard Before using the X-ray inspection system, ensure Never put any parts of the body inside the system that the protective lead curtains are in place and when the X-ray is on! the system is entirely fit for use! 5.2 Parts 5.2.1 X-ray generator The maximum power of X-ray tube is limited to Picture of the 200W. The maximum voltage value can be 80kV X-ray generator and maximum current value 5mA. The MIDMEKI control box. X-ray generator is software controlled and communicates over COM2 port. Power connection If the X-ray generator gives a message about communication error, make sure X-ray key is in COM2 RS-232 ON-position, then check the RS-232 and Power connections. 10 Rev Date Issued Version A 2014-10-20 DSY10003A 5.2.2 X-ray camera (AQU) The X-ray camera consists of a camera unit, a power supply unit, and cabling. AQU Camera consists of a sensitive detector, so be careful and protect it from impact, shocks or vibrations. AQU Camera is software-controlled via an USB connection. The AQU Camera is located inside the conveyor. At the bottom of the system there are several USB ports. One for camera (AQU) communication and two for other USB devices (USB mass storage, keyboard, etc.). Connect all cables in the right ports. All the ports and cables are labeled. AQU Camera power plug AQU Camera USB port 5.2.3 Conveyor The conveyor is made of stainless steel and the conveyor belt is approved for use in food industry. The conveyor speed with standard motor is up to 78m/min (1.3m/s). Conveyor speed can be set manually. To do so, open the access panel from the bottom of the right side. Adjust the speed from the button. 11 Rev Date Issued Version A 2014-10-20 DSY10003A 5.3 Electrical connections 5.3.1 Main switch The main power switch is located on the front side of the system. Main power switch 5.3.2 Power supply The Midmeki X-ray inspection system works with normal socket power. No high-voltage is needed. Before any maintenance or electrical modification work to the system, make sure that the power supply is disconnected and the power cable is unplugged! Power supply cable 5.3.3 Safety equipment and safety switches The system is equipped with safety contacts. These are located at the cabinet access panels and curtain casettes. The safety contacts are type NC (normally closed). The Emergency Stop buttons at front and back are NO (normally open). 12 Rev Date Issued Version A 2014-10-20 DSY10003A Before X-ray is powered, the safety contacts must be closed and the emergency stop open. If the safety contacts are open, the X-ray radiation is automatically turned off or does not start. Safety contact, cabinet access panel Emergency Stop Buttons: The system is equipped with three ESBs, one at the left and one at the right side of the system and one at the user panel. If any Emergency Stop buttons are pressed, the X-ray cannot be turned on. To start detection, release ESB by rotating it and press the Reset button. 5.3.4 Control switches The control switches are located at the front of the cabinet. 1. Switch for conveyor (when X-ray key in OFF- position): Conveyor ON/OFF. 2. X-ray indicator lamp. 3. X-ray key: Power supply for X-ray generator ON/OFF. 2 1 3 4 4. Reset button: Safety switch reset. 13 Rev Date Issued Version A 2014-10-20 DSY10003A 5.4 Mechanics 5.4.1 Cabinet and radiation shielding The cabinet is made of stainless steel plate. Radiation shielding is ensured by a collimator and lead plates inside the port construction. Radiation shielding in the port and port extensions is ensured by lead curtains. Also the AQU camera includes a lead shielding. 5.4.2 Mechanical construction The floorstand is equipped with four height adjustable feet, with which the system can easily be adjusted into the right height even if the ground is uneven. In addition the feet can be attached to the ground. 5.4.3 USB ports and Ethernet For data connection the system is equipped with 2 USB ports. These can be used for connecting to e.g. USB mass storage devices or a keyboard. MIDMEKI can be connected to the factory network over Ethernet. Picture from the bottom left of the system 14 Rev Date Issued Version A 2014-10-20 DSY10003A 5.5 The error messages 5.5.1 X-Ray detector –no response 1) Detector not found This error message appears if the computer is not able to communicate with the AQU Camera. Make sure USB and power cables of AQU are connected properly and restart the inspection software. 5.5.2 X-Ray generator –no response Make sure X-ray key is in ON-position, Emergency stop buttons are not pressed and access panels are closed. Also make sure curtain casettes are attached properly in the right position. After these, please press the Reset button. If these actions do not clear the error message, restart the inspection software. 5.5.3 Other error notifications These error messages are directly related to X-ray generator: 1) “Generator error-Temp High!“ “Generator error-Arc Fault!” – Generator overheating. First check and clean air-filter at the bottom of the system 2) “Generator error-High mA!” – Error, current value set too high 3) “Generator error-Low mA!” – Error, current value set too low 4) “Generator error-Low kV!” – Error, voltage value set too low 5) “Generator error-High kV!” – Error, voltage value set too high 6) “Generator error-Watchdog timer expired!” – Error, watchdog monitoring time-out 7) “Generator error-Power Limit” – Error, power limit exceeded 8) “I/O Machine Error” – I/O-error, error in power supply In the case of these error notifications, contact Mekitec Service-personnel! 15 Rev Date Issued Version A 2014-10-20 DSY10003A 5.6 Conveyor belt replacement 1. Shut down the software and Windows operating system. 2. Switch off the power. 3. Disconnect conveyor cables. 4. Open the front door. 5. Slightly lift up the conveyor and pull it out. 6. To remove the belt from the conveyor open the both lockings each side of the conveyor. 7. Fold the conveyor frame downwards around the hinges. 8. Now pull the belt out. 16 Mekitec Oy Tel. +358 20 741 0990 Teknologiantie 3 Fax +358 20 741 0991 90590 OULU [email protected] Finland http://www.mekitec.com
Copyright © 2024 DOKUMEN.SITE Inc.