Manual Table 4, the design process is an iterative one. A tentative design is conceived and then evaluated in terms of both the pavement luminance criteria and the STV. If the design, in terms of either criteria, is deficient then all or part of the design must be modified to correct the deficiencies. STV and average pavement luminances are minimums and both must be met or exceeded; exceeding one set of criteria does not permit reduction of the other. Pavement luminance uniformity should not be exceeded. If the design exceeds both the visibility and the pavement luminance criteria then the design may be modified (to reduce costs), or accepted depending on the judgment of the designer as to energy usage, aesthetics or other relevant consideration. The criteria values F6 The Iterative Design Procedure The use of computer programs to quickly evaluate a tentative design makes the use of the iterative design procedure simple. Under this procedure the initial tentative desi

March 24, 2018 | Author: rezapanah2013 | Category: Lighting, Contrast (Vision), Amplifier, Relay, Electrical Wiring


Comments



Description

PFC-6030 Fire Alarm Control PanelInstallation, Operation, & Programming Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 • Technical Support: (866) 956-1211 • Fax: (314) 595-6999 www.pottersignal.com Manual #5403595–Rev. A-2 10/11 PFC-6030 • 5403595 • Rev a-2 • 10/11 WARRANTY INFORMATION The essential purpose of any sale or contract for sale of any of the products listed in the POTTER catalog or price list is the furnishing of that product. It is expressly understood that in furnishing said product, POTTER does not agree to insure the Purchaser against any losses the Purchaser may incur, even if resulting from the malfunction of said product. POTTER warrants that the equipment herein shall conform to said descriptions as to all affirmation of fact and shall be free from defects of manufacture, labeling and packaging for a period of one (1) or five (5) year(s), depending on the product, from the invoice date to the original purchaser, provided that representative samples are returned to POTTER for inspection. The product warranty period is stated on the exterior of the product package. Upon a determination by POTTER that a product is not as warranted, POTTER shall, at its exclusive option, replace or repair said defective product or parts thereof at its own expense except that Purchaser shall pay all shipping, insurance and similar charges incurred in connection with the replacement of the defective product or parts thereof. This Warranty is void in the case of abuse, misuse, abnormal usage, faulty installation or repair by unauthorized persons, or if for any other reason POTTER determines that said product is not operating properly as a result of causes other than defective manufacture, labeling or packaging. The Aforesaid Warranty Is Expressly Made In Lieu Of Any Other Warranties, Expressed Or Implied, It Being Understood That All Such Other Warranties, Expressed Or Implied, Including The Warranties Of Merchantability And Fitness For Particular Purpose Are Hereby Expressly Excluded. In No Event Shall Potter Be Liable To Purchaser For Any Direct, Collateral, Incidental Or Consequential Damages In Connection With Purchaser’s Use Of Any Of The Products Listed Herein, Or For Any Other Cause Whatsoever Relating To The Said Products. Neither Potter Nor Its Representatives Shall Be Liable To The Purchaser Or Anyone Else For Any Liability, Claim, Loss, Damage Or Expense Of Any Kind, Or Direct Collateral, Incidental Or Consequential Damages Relative To Or Arising From Or Caused Directly Or Indirectly By Said Products Or The Use Thereof Or Any Deficiency, Defect Or Inadequacy Of The Said Products. It Is Expressly Agreed That Purchaser’s Exclusive Remedy For Any Cause Of Action Relating To The Purchase And/or Use Of Any Of The Products Listed Herein From Potter Shall Be For Damages, And Potter's Liability For Any And All Losses Or Damages Resulting From Any Cause Whatsoever, Including Negligence, Or Other Fault, Shall In No Event Exceed The Purchase Price Of The Product In Respect To Which The Claim Is Made, Or At The Election Of Potter, The Restoration Or Replacement Or Repair Of Such Product. Potter Electric Signal Company, LLC 5757 Phantom Drive Ste 125 • St. Louis, MO 63042 • 314-595-6900 • 800-325-3936 2 PFC-6030 • 5403595 • Rev a-2 • 10/11 Table of Contents Section 1: Introduction.............................................................................................................................. 1-1 Purpose of This Manual...........................................................................................................................1-1 System Overview.....................................................................................................................................1-1 System Features.......................................................................................................................................1-1 P-Link Accessories.............................................................................................................................1-1 SLC Loop Accessories. .......................................................................................................................1-2 Addressable Sensors..........................................................................................................................1-2 Addressable Modules.........................................................................................................................1-2 How to Use this Manual..........................................................................................................................1-2 Common Terminology.............................................................................................................................1-2 Section 2: Before You Start Installation................................................................................................... 2-3 System Specifications..............................................................................................................................2-3 Environmental Specifications..................................................................................................................2-3 System Configurations / Appliances........................................................................................................2-3 Electrical Specifications. .........................................................................................................................2-4 System Size Specifications......................................................................................................................2-4 Main Board Wiring Specifications. .........................................................................................................2-5 Circuit Separation..............................................................................................................................2-5 Wiring Types. ......................................................................................................................................2-5 Cabinet Dimensions.................................................................................................................................2-6 Cabinet Wiring Connections....................................................................................................................2-7 Battery Circuit Calculations. ....................................................................................................................2-8 Battery Calculation Worksheets. .............................................................................................................2-8 SLC Current Draw Worksheet.................................................................................................................2-9 Isolator Device Load Calculation..........................................................................................................2-10 Scenario 1: Class A Loop – Isolated Devices Configuration..........................................................2-10 Scenario 2: Class B Loop – Isolated Branch Configuration...........................................................2-11 Battery Connections...............................................................................................................................2-12 Main Supply Circuit. ..............................................................................................................................2-12 Section 3: Installation.............................................................................................................................. 3-13 Signaling Line Circuit (SLC) Installation..............................................................................................3-13 SLC Wiring Requirements................................................................................................................3-13 Class B, Style 4 Wiring Configuration.............................................................................................3-13 Class A, Style 6 Wiring Configuration.............................................................................................3-14 Class A, Style 7 Wiring Configuration.............................................................................................3-15 Connecting Analog Detectors................................................................................................................3-15 Connecting Addressable Modules.........................................................................................................3-16 Conventional Initiating Zones (CIZM-4) Class A. ...........................................................................3-16 Conventional Initiating Zones (CIZM-4) Class B. ...........................................................................3-16 Miniature Contact Module (MCM)..................................................................................................3-17 Single Contact Module – 4 inch Mount (SCM-4)............................................................................3-17 Dual Contact Module – 4 inch Mount (DCM-4).............................................................................3-17 Twin Relay Module – 4 inch mount (TRM-4). ..................................................................................3-18 Monitored Output Module – 4 inch mount (MOM-4)......................................................................3-18 Connecting Analog Sounder Base (ASB).........................................................................................3-19 Connecting Analog Relay Base (ARB). ............................................................................................3-19 3 ..................................................................3-24 P-Link Addresses..............................3-24 Configuration Characteristics............5-46 Programming Functions Overview.............................................................................................................................................................................................................................................................................................................................................................................................................5-40 File Save / Save As..................................................................................................................................................................................................................................................................................................................................4-31 Section 5: Programming.................4-28 LCD Display..........................................5-39 Downloading Configuration File to Panel..................................................4-29 Function Pushbuttons.......................................................... 5-32 Programming Options.....................3-27 Section 4: Operation..........................................................................................................................................5-43 History Reports.........................................................................................................................................................................................................................................................................................................5-36 Transferring Data.........................................5-36 Connecting the Computer and Panel.................5-40 Enable Remote Access..........................................................................................................................................................................................5-48 User Name / Password...................... ............................4-30 Status LEDs..................................PFC-6030 • 5403595 • Rev a-2 • 10/11 Addressing SLC Devices.........................................................................3-26 Dip Switch Location..5-41 Audit Errors....................................................................................... ....................................................................................................................... ............................................................................................................................................................................................................4-30 Control Panel Menu Tree...............3-23 CA-6075 Class A Expander.......................................................... 4-28 Control Panel Basic Operation.....4-28 Menu Navigation Keys.................................................................................................................4-29 Numeric Keypad..............................5-45 Window Regions / Areas...................................5-48 4 ..............................................................................................5-41 Downloading a Configuration File..............................................................................................................................................................................................................................................................................................................................3-22 NAC Wiring.......................................................................................................................................................................................5-32 Programming Overview.........................................................3-26 Installing the DACT.............................................................................................................................................................. ................ .......5-44 Panel Software Overview.....5-35 The Programming Cycle...............................................................................................................................................3-23 P-Link Devices..........................................................................................................................................5-43 Detector "Sensitivity" Status Reports........ ..................................................... ..................................3-22 Relay Output Wiring....................................................................... ......................................................................................................... ..............................3-22 NAC Maximum Wiring Impedance Formula.................................................................................................................................................................5-47 Remote Access Code.......3-24 Maximum Wire Resistance Formula............................................................5-35 Software Installation..........5-42 Uploading History Events & Detector "Sensitivity" Status Reports....................5-38 Uploading from Panel to Computer......................................................................................................................................................................................................................................................................................................... ....................................................................................................................................................................................................................................................... ..................................................................5-45 Program Icons..........................3-20 Notification Appliance Circuits Installation...................................................................................................5-35 LEARN Programming...............................................3-25 Installing Remote Annunciators................................................................................................ .....................................................................................................................................................................................................5-57 System Programming............5-49 Job Details...................................................5-73 Reporting Accounts........................................................................................................5-60 Zone Types / Styles.................................. A-1 Appendix B: Modem Connectivity Setup..............................................................................................................................................5-49 General Options..................................................................................................................................................................................................5-59 Mapping Zones Overview..............................................5-53 Connecting the Panel to a Network................................................................................................... C-1 Appendix D: Compatible Devices Table........................................................................................................ D-1 Appendix E: Troubleshooting Tips..................................................................................................................................................................................................................................................................5-72 Programming Optional Modules.............................................................................................................................................................................................................................................................................................................................................................................E-1 Appendix F: Control Panel Menu.......................................................................................................................................................................................................................... .................................................................................................5-65 SLC Functions...5-51 System E-mail Functions............................................................................................................................................................... ............................................... ................................................................................................................5-69 Group by Area......................................................................5-55 Receiving E-mail Status Reports...........................................................................................................5-60 Zone Attributes.............................................................................................................................................................PFC-6030 • 5403595 • Rev a-2 • 10/11 General System Functions.....................................5-54 E-mail Report Requested from PC................................................................... ....................................................................................................................................................................................5-59 Single Zones......................................................................................................................................................................5-73 CA-6075 Class A Converter Module....................................................................................................................................................................................................................................5-52 P-Link E-mail Notification Requirements...................5-75 Remote Annunciators (RA-6075)..........................................................................................................5-53 E-mail Sent from Panel........................................................................................................................5-59 Multiple Zones........5-59 Mapping Terminology.............................................5-73 DACT (UD-1000)............. .....................................................B-1 Appendix C: System Maintenance and Testing................................5-63 Configuring Points..............................................5-71 Cross Zone Configurations................................5-61 Creating Zones.................................................................................................................................5-49 Day/Night Sensitivity Mode and Holiday Scheduling.........................5-50 Users...................................................................5-76 Appendix A: Basic Operating Instructions............... F-1 5 ....................................................5-66 Adding Points to Zones......................5-65 NAC Functions...................................................... NFPA-72. System Features yy The PFC-6030 features a built in signaling line circuit (SLC) capable of supporting 30 Potter/Nohmi protocol devices. NFPA-13. Vista and Windows™ 7. microprocessor based addressable fire control panel and complies with UL-864. yy 3. P-Link communication bus and the two (2) built-in NAC circuits 1-1 . yy P-Link RS-485 bus supports system accessories. The two (2) on-board circuits' (NAC 1 and 2) operational mode behavior can be customized. System Overview The PFC-6030 system is designed for use as a fire control panel for life safety applications. The PFC-6030 system software is compatible with Windows™ XP. It is recommended that the user follows the procedures as outlined in this manual to assist in proper installation and prevent damage to the control panel and associated equipment. yy Potter yy Gentex® yy CooperWheelock® yy System Sensor® yy Built-in Ethernet port for programming and network connectivity.PFC-6030 • 5403595 • Rev a-2 • 10/11 Section 1: Introduction The Model PFC-6030 is a listed and approved. the latest version of . Purpose of This Manual This manual is intended to assist in the installation and programming the PFC-6030 Fire Alarm Control Panel.NET Framework is required. This flexibility enables configuration of system points to maximize protection throughout controlled site(s). Supervisory and Trouble Form C Relays yy Analog / Addressable Sensing Technology yy Drift Compensation yy Maintenance Alert yy NFPA 72 compliant calibrated smoke test built-in P-Link Accessories yy RA-6075 Remote Annunciator – Maximum of 31 per system yy UD-1000 Dual Line Fire Communicator – Maximum of 1 per system yy CA-6075 Class A converter module – Maximum of 1 per system allows for Class A wiring of the SLC circuit. and provides great flexibility in effectively programming individual or groups of devices. yy Learn mode enrolls connected sensors and modules for efficient system programming. additionally. yy Power Limited yy Built in Sync yy Cadence Patterns yy Auxiliary Power yy Support for all major synchronization patterns. and CSFM.000 event non-volatile history buffer. Refer to this manual to properly install and program the PFC-6030. yy 1.5 Amp 24vdc Power Supply yy Two (2) Notification Appliance Circuits (NACs) each rated at 3. It incorporates conventional shortcuts.0 Operating Systems. yy Ninety-nine (99) Software Zones yy Dead-front Cabinet Design yy 2 X 16 character LCD display yy Dedicated Alarm.0 Amps maximum. yy Built-in e-mail support to communicate system status and event information. PFC-6030 • 5403595 • Rev a-2 • 10/11 SLC Loop Accessories • Addressable Sensors yy Photoelectric Smoke Detector (PSA) yy Photoelectric/Heat Smoke Detector (PSHA) yy Fixed Temperature Heat Detector (FHA) yy Rate of Rise/Fixed Temperature Heat Detector (RHA) yy Addressable Isolator Base (AIB) yy Addressable Relay Base (ARB) yy Addressable Sounder Base (ASB) Addressable Modules yy Miniature Contact Module (MCM) yy Single Contact Module (SCM-4) yy Dual Contact Module (DCM-4) yy Twin Relay Module (TRM-4) yy Monitored Output Module (MOM-4) yy Conventional Input Zone Module (CIZM-4) yy Short Circuit Isolator (SCI) • How to Use this Manual Refer to this manual before contacting Technical Support. and other guidelines specific to the PFC-6030 system. system requirements. The information in this manual is the key to a successful installation and will assist you in understanding proper wire routing. Common Terminology The following table provides you with a list of terms and definitions used with the PFC-6030 system: Term PFC-6030 Cabinet EOLD or Diode Assembly EOLR Remote Annunicator NAC SLC DACT Table 1: Terminology Definition Enclosure End of Line Diode Assembly End of Line Resistor Assembly LCD type Remote Annunicator Notification Appliance Circuit Signaling Line Circuit Digital Alarm Communicator Transmitter (UD-1000) 1-2 . reaming. locked door yy Enclosure dimensions – 16” x 17” x 3 7/8” yy Non-removable locked door Visual Indicators yy LCD (2x16 alphanumeric character display) yy LED indicators (Red. removable. specifications. has no affect on the applicable section. status and circuit for each correlating condition Environmental Specifications yy yy yy yy yy Mount indoors only. not required for applicable section O = Optional. and calculating the battery circuit and SLC current draw requirements. or punching of the enclosure. System Configurations / Appliances Table 2: System Configurations / Appliances Model PFC-6030 CA-6075 UD-1000 RA-6075 3005013 3005012 Description Main Board/Panel Assembly Class A Expander DACT LCD type remote Annunciator End of line resistor assembly End of line resistor and diode Local Y O N O Y N Auxiliary Y O N O Y Y Remote Station Y O Y O Y N Central Station Y O Y O Y N Proprietary Y O Y O Y N Y = Yes. such as the PFC-6030 cabinet layout. When possible. Verify that they will not interfere with the batteries or other components. filing. System Specifications Cabinet Description yy Sixteen (16) gauge sheet steel with hinged. may or may not be used. Amber) LCD Description yy Alarm. 2-3 . Green. bottom. environmental considerations. required for applicable section N = No. Remove all electronic assemblies prior to any drilling. Verify panel is properly grounded. The panel and system must be tested and maintained in accordance with all local and national codes and ordinances. Temperature 32° to 120°F. or rear of the cabinet. make all cable entries from the sides. humidity 93% non-condensing. Supervisory and Trouble conditions display applicable condition.PFC-6030 • 5403595 • Rev a-2 • 10/11 Section 2: Before You Start Installation This section addresses information that will help you in completing a successful installation. and P-Link are Power Limited PFC-6030 2 NACs 3 Amp Maximum Load of 56. One (1) DACT 2-4 . • Two (2) notification circuits on the main board.PFC-6030 • 5403595 • Rev a-2 • 10/11 Electrical Specifications Please refer to the table below for electrical specifications: Table 3: System Panel Electrical Specifications Panel # NACs Rating per NAC SLC Power Notes Style and Class SLC – Class A or B NAC – Class A or B P-Link – Class A or B SLC. NACs.055 mA Maximum of 30 addressable points System Size Specifications Please refer to the table below for system size specifications: Table 4: System Size Specifications Accessories/Subassemblies PFC-6030 UD-1000 Maximum System Size • 30 point any combination of detectors or modules. and (2) wiring types. The control panel cabinet has sufficient knockouts located around the periphery allowing the installer to maintain separation between power limited and non-power limited connections.PFC-6030 • 5403595 • Rev a-2 • 10/11 Main Board Wiring Specifications There are several wiring requirements to consider before connecting circuits to the main board: (1) the circuit separation. Non-Power Limited. Wiring Types Wiring specifications must be followed to prevent damage and/or or other consequences. yy yy Separations between the different wiring types must be maintained by at least ¼ inch and the wire insulation must be for the higher voltage. Circuit Separation Proper separation between the different types of circuits must be maintained between Power Limited. Refer to table below for a breakout of the different wiring requirements shown by circuit type: Table 5: Main Board Circuit Wiring Types Wiring Type Type of Circuit AC Connection Battery Connection Trouble Relay Supervisory Relay Alarm Relay Notification Device Circuits (NACs) P-Link RS-485 Connections Signaling Line Circuit Phone Line – DACT Voltage High Voltage Low Voltage Low Voltage Low Voltage Low Voltage Low Voltage Low Voltage Low Voltage High Voltage Power Non-Power Limited Non-Power Limited Non-Power Limited Non-Power Limited Non-Power Limited Power Limited Power Limited Power Limited Non-Power Limited 2-5 . transient voltage or voltage ratings. and High Voltage wiring to reduce electrical interferences. 78 " BACKBOX = 16.77" DEPTH = 3.75 " DOOR = 16. PFC-6030 Cabinet Dimensions TOP DEPTH = 3.07" BACKBOX = 15.PFC-6030 • 5403595 • Rev a-2 • 10/11 Cabinet Dimensions Figure 1.84 " LEFT SIDE DOOR = 16.56" RIGHT SIDE BOTTOM DWG #593-1 2-6 . PFC-6030 • 5403595 • Rev a-2 • 10/11 Cabinet Wiring Connections Figure 2. PFC-6030 Cabinet Wiring UD-100 DACT High voltage phone connections Optional 120VAC 50Hz-60Hz 240VAC 50Hz-60Hz Connect to separate unswitched AC circuit POWER EARTH FAULT SILENCED SILENCE ALARM SUPERVISORY TROUBLE RESET 1 4 7 2 5 8 0 3 6 9 ESC Optional CA-6030 Class A Expander ACK DRILL ENTER Non-power limited battery connection Power limited wiring Non-power limited relay connection 18Ahr 12Volt 18Ahr 12Volt DWG # 593-2 2-7 . 4) Door holder circuits configured to disconnect upon AC loss need not be included in the battery standby calculation since they will not draw power during that time.85 *Maximum Allowable Standby Current (UL 24-Hour standby time) 7 AH .930 A Important Notes: 1) FACP enclosure can house up to two (2) 18 AH batteries.Calculated by SLC worksheet Quantity 1 Standby (mA) 130 20 12 16 Total Standby (mA) Alarm (mA) 220 25 44 23 Total Alarm (mA) Total (ma) Convert to Amps (*Refer to maximum allowable standby current) Total A: x 0.001 Multiply by standby hours x____ Example: 5 minute alarm: enter 12 10 minute alarm: enter 6 Total Alarm AH +Total Standby AH Total AH Efficiency Factor Required AH ÷ ____ Total Standby AH ÷ 0. 2) NFPA 72 require 24 hours of standby power followed by 5 minutes alarm activation. Please use the Battery Calculation Worksheet and SLC Current Draw Worksheets to calculate the battery size and current draw required for each application and SLC. it is important to determine the minimum size batteries for standby and alarm times desired for each application and SLC current draw. 12A require 24 hours and five minutes of alarm activation.619 A 33 AH 1. If the wrong batteries are installed in a specific application or incorrect current draw used. The battery circuit is rated for 8 to 55 AH batteries and will operate the panel alarm for at least 24 hours and 5 minutes. Door holders will contribute to standby current draw when AC is present. The cabinet will house up to two (2) 8 AH or two (2) 18 AH batteries.001 Total ma Convert to Amps Total A: 60 minutes per hour Alarm time (minutes) x 0. the proper standby and minimum alarm time will not be present.230 A 18 AH . 5) Total current must not exceed power supply rating (3. Battery Calculation Worksheets Description Main board (PFC-6030) LCD Remote (RA-6030) CA-6075 Class A Expander UD-1000 DACT NAC 1 NAC 2 SLC Current Draw .5A on PFC-6030). Larger batteries require accessory enclosure from Potter Electric. 2-8 . 3) NFPA 12.PFC-6030 • 5403595 • Rev a-2 • 10/11 Battery Circuit Calculations Before selecting the battery.151 A 55 AH 1. 4 inch mount (DCM-4) Monitored output module .325 0.4 inch mount (MOM-4) *Note 2 Twin relay module .325 0.4 inch mount (SCM-4) Dual contact module .325 0. Alarm Current = 1. Style B (8.325 0.325 1.90 mA.325 0.325 0.325 1.000 1.000 0.325 0.325 0.325 n/a SLC Alarm Current 27. Alarm Current = 50. Standby current Style D = 4. Standby current = 1.325 0.325 0.4 inch mount (TRM-4) Short circuit isolator (SCI) Analog sounder base (ASB) Analog relay base (ARB) Isolator base (AIB) SLC alarm LED Current n/a Qty Standby (mA) 0.325 0.325 0.5 mA).000 1.325 0.325 0.000 1.PFC-6030 • 5403595 • Rev a-2 • 10/11 SLC Current Draw Worksheet Device Type Analog photo smoke detector (PSA) Analog photo DUCT smoke detector (DSA) Analog photo smoke / fixed heat detector (PSHA) Analog fixed heat detector (FHA) Analog combo heat detector (RHA) Conventional initiating zone module .325 0.325 0.325 0.6 mA.325 n/a SLC Standby Current Total Standby (mA) Alarm (mA) 0.60 mA 2-9 .325 0.325 0.325 0.000 0.4 inch mount (CIZM-4) *Note 1 Miniature contact module (MCM) Single contact module .325 0.0 mA * Note 2: MOM requires 24VDC power source.0 Total Alarm (mA) * Note 1: CIZM requires 24VDC power source. up to 127 power unit allocations are allowed. but does consume power. A device uses an address and consumes power. Scenario 1: Class A Loop – Isolated Devices Configuration In this configuration. Note: The maximum number of addresses allowed is 30. Total device load = 17 (8 sensors + 9 isolators) out of 127 power unit allocations. Example of a Class A Loop – Isolated Branches LEGEND: ISO Module/ Device Sensor Total addressable devices = 8 Total isolators = 9 PANEL DWG # 593-4 Configuration Summary: Total addressable devices = 8 (sensors only) out of 30 possible addressable points. Solution: 127 . an isolator does not use an address. Example: If a SLC configuration uses 30 sensors. up to 97 isolators may be supported.PFC-6030 • 5403595 • Rev a-2 • 10/11 Isolator Device Load Calculation This section covers the distinction between an addressable sensor and an isolator to correctly calculate the total SLC device load. each sensor and isolator device / module counts as one (1) when calculating the total device load. Whereas. The following scenarios explain how to calculate the current device load based on the SLC configuration.30 = 97 2-10 . Formula: Total # addressable devices + Total # isolators = Total power unit allocations (or device load) Figure 3. however. there are 4 separate branches each with an isolation device / module and 1 or more sensors. refer to the following rule: Device Load Rule for Branch Configurations Count all devices. allocate 8 as the device load. in this configuration. Figure 4. including isolators. 2-11 . • If the count is >8. Total device load = 34 out of a possible 127 power unit allocations. as shown in Scenario #1. each isolator consumes power equal to 8 devices. however. Each sensor requires an address. • If the count is <=8. allocate the actual device count number.PFC-6030 • 5403595 • Rev a-2 • 10/11 Scenario 2: Class B Loop – Isolated Branch Configuration In this configuration. on the branch. To calculate the total device load. Example of a Class B Loop – Isolated Branches BRANCH #1 LEGEND: ISO Module/ Device BRANCH #2 Sensor Total devices = 2 Total devices = 3 Total devices = 10 BRANCH #3 BRANCH #4 Total devices = 4 PANEL DWG #593-3 Configuration Summary: Branch #1 has 3 devices = 8 power allocations Branch #2 has 2 devices = 8 power allocations Branch #3 has 10 devices = 10 power allocations Branch #4 has 4 devices = 8 power allocations Total addressable devices = 15 (sensors only) out of 30 addressable points. but isolators do not. 3 VDC and is supervised. The maximum battery charging circuit is 1. Maximum of 2A at the nominal 240 VAC rating. Connect the battery wire leads to the terminal connections. The earth ground connection is marked as “G” and is the furthest connection from the line voltage connection. AC POWER AC120V/AC230V. The main board supervises the main AC power and provides indication that the AC power is absent. Batteries should be replaced every five (5) years or sooner depending on annual testing.0 amp DC. PFC-6030 Battery Connections - BATTERY + Panel Connections 12 V Battery + 12 V Battery + DWG # 593-5 Main Supply Circuit The AC terminals are located in the upper left hand portion of the main board. Figure 5. Figure 6.PFC-6030 • 5403595 • Rev a-2 • 10/11 Battery Connections The battery charging circuit is located on the main panel in the lower left portion of the board. the charging voltage is approximately 27.50/60Hz 2-12 . Note: The battery should be clearly labeled as “Sealed Lead Acid Battery” or equivalent. The AC input power ratings are as follows: • • Maximum of 3A at the nominal 120 VAC rating. as shown. PFC-6030 AC Terminals 120VAC 50/60 Hz 240VAC 50/60 Hz Connect to separate Unswitched AC circuit Black White Ground B W G DWG #593-6 The terminals are rated at 120 VAC/240 VAC 50/60 Hertz and are marked accordingly on the board. xxxxxx Document: TN51313e date:XX.5 micro farads. Style 4 PFC-6000 Series SLC Loop (Class B) Terminal Connections 7 Address No.2009 Compatibility Identi er: INTE01 WARNING : Power supply for terminals 24+ and 24.B+ A.1kΩ 3-13 . and Remote Annunciators. All devices require an address prior to connecting to the control panel. Maximum loop capacitance must be 0. S- S+ C NO (NC) UL Potter Electric Signal Company Miniature Contact Module Model No. Total resistance must be below 50 ohms.2009 WARNING: All Terminals are power limited FIRE ALARM EQUIPMENT XXXX FIRE ALARM EQUIPMENT XXXX 8 3 B. Wiring requirements and configuration examples are included throughout this section.1kΩ 24. DWG # 593-7A 5. SIGNALING LISTED 5. MCM Ser. Class B. Instructions for addressing SLC devices which must be completed before programming your system are also included.1 ohm per SCI. No.A+ UL LISTED SIGNALING Address No. All SLC wiring is low voltage and power limited. Maximum wire resistance must be calculated based on 0.PFC-6030 • 5403595 • Rev a-2 • 10/11 Section 3: Installation This section addresses installation procedures for SLCs. No.must be power limited All Terminals are power limited. Signaling Line Circuit (SLC) Installation The SLC panel provides power and communication to each of the sensors and modules connected.Class B. xxxxxx Document: TN51314e date: XX. and input or output modules. Style 4 Wiring Configuration Figure 7. heat detectors. Class A Card. This panel has a total loop capacity of 30 addressable points configured in any combination of smoke sensors.24+ S- S+ 6 Potter Electric Signal Company Conventional Initiating Zone Module Model No. Please read this section carefully before installing devices and/or modules to insure proper installation. Example of SLC Wiring . Refer to “Addressing SLC Devices” located later in this section for details.XX. CIZM-4 Ser. including the DACT. NACs and optional modules.XX. SLC Wiring Requirements The wiring parameters listed below MUST be followed to ensure proper installation: • • • • • Maximum wiring resistance between two (2) Short Circuit Isolators (SCIs) must be less than 10 ohms. 2.B+ A. 4. S- S+ C NO (NC) UL Potter Electric Signal Company Miniature Contact Module Model No. The Class A.2009 Compatibility Identi er: INTE01 WARNING : Power supply for terminals 24+ and 24.24+ S- S+ Potter Electric Signal Company Conventional Initiating Zone Module Model No.XX. Style 7. DWG # 593-7A 5. Class A.A+ UL LISTED SIGNALING Address No. MCM Ser.1kΩ 24.PFC-6030 • 5403595 • Rev a-2 • 10/11 Class A.1kΩ Notes: 1. xxxxxx Document: TN51314e date: XX. No. SIGNALING LISTED 5.XX. 3-14 . No.2009 WARNING: All Terminals are power limited FIRE ALARM EQUIPMENT XXXX FIRE ALARM EQUIPMENT XXXX 8 3 B. The SLC connection requires that the wires are separated 10’. Maximum wiring resistance must not exceed 50 ohms. 3. xxxxxx Document: TN51313e date:XX. CIZM-4 Ser. The use of a SCI or AIB is not required. Style 6 Wiring Configuration Figure 8.must be power limited All Terminals are power limited. 5. Style 6 configuration does not provide the level of protection as Class A. installed in conduit or other mechanical protection. Style 6 Requiring CA-6075 PFC-6000 Series SLC Loop (Class B) Terminal Connections 7 6 Address No. Example of Class A. Style 7 requires installation of a CA-6075. B. NO2 Z2 (NC2) C2 NO1 Z1 (NC1) C1 PFC-6000 Series SLC Loop (Class A Style 7) Terminal Connections SCI 5. SCI Ser. UL UL UL FIRE ALARM EQUIPMENT XXXX FIRE ALARM EQUIPMENT XXXX FIRE ALARM EQUIPMENT XXXX WARNING : All Terminals are power limited. SIGNALING LISTED S-2 S+2 S-1 S+1 Potter Electric Signal Company Short Circuit Isolater Model No. 3. xxxxxx Document: TN51313e date:XX. UL UL UL FIRE ALARM EQUIPMENT XXXX FIRE ALARM EQUIPMENT XXXX FIRE ALARM EQUIPMENT XXXX WARNING : All Terminals are power limited. SIGNALING 24. Figure 10. 4.XX. No. such as a photoelectric smoke sensor (PSA).2009 Potter Electric Signal Company Dual Contact Module Model No. xxxxxx Document: TN51316e date:XX.1kΩ SCI DWG #593-9 Notes: 1. SIGNALING S-2 S+2 S-1 S+1 Potter Electric Signal Company Short Circuit Isolater Model No. Class A. SCI Ser. An analog detector activates its response LED when activated. Style 7 Wiring Configuration Figure 9.Class A. SCI Ser. SCI Ser.must be power limited All Terminals are power limited. Connecting Analog Detectors When installing analog detectors.A+ SCI 5. SIGNALING S-2 S+2 S-1 S+1 Potter Electric Signal Company Short Circuit Isolater Model No. photo smoke/fixed heat detector (PSHA).XX.XX. 2.1kΩ SCI Address No. SIGNALING S- S+ LISTED Address No. No. WARNING : All Terminals are power limited. CIZM-4 Ser. Style 7 requires installation of an isolator close nipple connected to every module or sensor.2009 LISTED Address No.PFC-6030 • 5403595 • Rev a-2 • 10/11 Class A. Style 7 requires installation of a CA-6075.e. use detector bases (i.XX.2009 Potter Electric Signal Company Conventional Initiating Zone Module Model No. or an analog combination type heat detector (RHA). No. Maximum wiring resistance must not exceed 50 ohms.2009 WARNING : All Terminals are power limited. WARNING : All Terminals are power limited. SIGNALING LISTED S-2 S+2 S-1 S+1 Potter Electric Signal Company Short Circuit Isolater Model No. xxxxxx Document: TN51313e date:XX.XX. heat detector (FHA). Style 7 Requiring CA-6075 Address No. xxxxxx Document: TN51313e date:XX.2009 Compatibility Identi er: INTE01 WARNING : Power supply for terminals 24+ and 24. No. Isolators may be either a SCI or an AIB addressable base.1kΩ 5. AB-6). Example of SLC Wiring . DCM-4 Ser.B+ A. No. xxxxxx Document: TN51313e date:XX. xxxxxx Document: TN51313e date:XX. An example of wiring an analog detector is shown below.24+ S- S+ LISTED Address No. Analog Detector Wiring Example S+ S+ From FACP or the previous addressable device on the SLC loop To the next addressable device SS- DWG #593-10 3-15 .2009 LISTED Address No. The Class A. The SLC connection requires that the wires are separated by a minimum of 10’ and installed in conduit or other mechanical protection. No.XX. Therefore.1KΩ 1/2W EOLR LED Conventional Initiating Zone Module Model No. Miniature Contact (MCM). 3. CIZM-4 To Next Module Note: The resistance of external wiring shall be less that 100Ω. Class B From FACP or Previous Module SLC Loop S+ Select Style B JP1 Conventional Detector B+ BA+ A- To Next Module From FACP or Previous Module S24+ 24- + _ + _ + _ 5. Single Contact (SCM-4). Conventional Initiating Zones (CIZM-4) Class B Figure 12. Conventional Initiating Zones (CIZM-4) Class A Figure 11. including Conventional Initiating Zones (CIZM-4). 2. Analog Relay (ARB) and Analog Sounder Base (ASB) modules. The capacitance of external wiring shall be less than 1 micro farads. 4. In this style. DWG #593-12 3-16 . Twin Relay (TRM-4). The resistance of external wiring shall be less than 100 ohms. Refer to the CIZM data sheet for information on compatible devices.PFC-6030 • 5403595 • Rev a-2 • 10/11 Connecting Addressable Modules This section provides examples of wiring addressable modules. The capacitance of external wiring shall be less than 1 micro farads. the system MUST be reset at the control panel after clearing the open circuit condition at the site. Dual Contact Module (DCM-4). Monitored Output (MOM-4). CIZM-4. the open circuit “trouble condition” of IDC is latched at the control panel until system is reset. CIZM-4. The capacitance of external wiring shall be less than 1 micro F. CIZM-4 LED To Next Module DWG #593-11 Notes: 1. Class A From FACP or Previous Module SLC Loop To Next Module From FACP or Previous Module S+ S24+ 24- Note: The resistance of external wiring shall be less that 100Ω. JP1 Select Style D Conventional Detector B+ BA+ A- + _ + _ + _ Conventional Initiating Zone Module Model No. NO1 C1 From FACP or Previous Module S+ S- Z1 NO2 C2 Z2 LED SLC Loop JP1 To Next Module Select Style 6 DWG #593-15 Note: In this configuration. SCM-4 Wiring Example Note: The resistance of external wiring shall be less that 100Ω.1KΩ 1/2W EOLR COM To Next Module S+ S- NO Z LED SLC Loop From FACP or Previous Module Single Contact Module Model No. SCM-4 DWG #593-14 Dual Contact Module – 4 inch Mount (DCM-4) Refer to the figure shown below for a Class A DCM-4 wiring example.1KΩ 1/2W EOLR NO COM To Next Module S+ S- SLC Loop Mini Contact Module Model No. The capacitance of external wiring shall be less than 1 micro farads. Figure 13. MCM DWG #593-13 From FACP or Previous Module Note: If MCM is located in an electrical box. MCM Wiring Example Note: The resistance of external wiring shall be less that 100Ω. DCM-4 Note: The resistance of external wiring shall be less that 100Ω. Figure 15. The capacitance of external wiring shall be less than 1 micro farads. 5. 3-17 . DCM-4 with One Class A Circuit Dual Contact Module Model No. The capacitance of external wiring shall be less than 1 micro farads. the DCM-4 operates as a single point Class A module. Single Contact Module – 4 inch Mount (SCM-4) Refer to the figure shown below for a SCM-4 wiring example. it should be secured using crew tabs or other method to prevent movement.PFC-6030 • 5403595 • Rev a-2 • 10/11 Miniature Contact Module (MCM) Refer to the figure shown below for a MCM wiring example. Figure 14. 5. 0A 125VAC / . Normal output is nonpowerlimited.PFC-6030 • 5403595 • Rev a-2 • 10/11 When configuring a Class B. Figure 17.5A S+ SNO1 C1 Normally Open 1 Common 1 Normally Closed 1 Normally Open 2 Common 2 Normally Closed 2 LED DWG.1KΩ 1/2W EOLR LED Monitored Output Module Model No. unless the power supply connected to the TRM-4 is power-limited and the circuits are power-limited. If address No. C1) will be addressed as No. Refer to the figure below for an example of wiring a Class B DCM-4. the DCM-4 has two (2) addresses. Example of MOM-4 with NAC Connections Note: The resistence of external wiring shall be less that 100Ω. TRM-4 NC2 To Next Module Monitored Output Module – 4 inch mount (MOM-4) If the power supply connected to the MOM-4 is power limited.2 (NO2. A MOM-4 wiring example is shown below. The capacitance of external wiring shall be less than 1 micro farads. then the outputs are power limited.1.1 (NO1. MOM-4 To Next Module DWG #593-18 3-18 . C2) will automatically be addressed as No. #593-17 From FACP or Previous Module NC1 NO2 C2 SLC Loop Twin Relay Module Model No. Figure 18.0A A+ A- From FACP or Previous Module SLC Loop To Next Module From FACP or Previous Module S+ S24+ 24- + _ + _ + _ 5. input circuit No. Dual Contact Module Model No. The capacitance of external wiring shall be less than 1 micro farads. Figure 16. DCM-4 with Two Class B Circuits Note: The resistance of external wiring shall be less that 100Ω. Example of TRM-4 Wiring Contact Rating: 24VDC / 2. DCM-4 Address # NO1 C1 Z1 From FACP or Previous Module S+ S- NO2 Address #+1 SLC Loop JP1 C2 Z2 LED To Next Module Select Style 4 DWG #593-16 Twin Relay Module – 4 inch mount (TRM-4) The TRM-4 has two (2) contacts that are active simultaneously when TRM-4 is in the active mode. and input circuit No.2.1 is set. JP1 Select DC Notification Appliance Output Rating: 24VDC / 2. Example of Analog Relay Base Wiring SLC Loop From FACP or Previous Module 24 VDC24 VDC+ SLC Loop 24+ NO1 24. Connecting Analog Relay Base (ARB) Figure 20.0A / 240VAC 2. ARB DWG #593-20 3-19 . Example of Analog Sounder Base Wiring SLC Loop 24 VDC+ 24 VDC24 VDC24 VDC+ To Next Module From FACP or Previous Module SLC Loop S+ SS+ STB1 24+ 24- Analog Sounder Base Model No. 2.0A / 240VAC 8.C1(8A) S+ SS+ STB1 24 VDC24 VDC+ To Next Module NC1 NO2 C2(2A) NC2 TB2 NO1 C1(8A) LED NC1 NO2 C2(2A) NC2 TB2 8. The supply power must be coded in order for the output to be coded.PFC-6030 • 5403595 • Rev a-2 • 10/11 Connecting Analog Sounder Base (ASB) Figure 19. ASB does not generate a coded output.0A / 30VDC Analog Relay Base Model No.0A / 30VDC 2. It will track the pattern delivered to its 24 VDC input. ASB DWG #593-19 Notes: 1. 2. yy Press ENTER to select. 3. Control Panel Showing SLC PGM Terminal Main Menu 1=View History 2=Enable/Disable 3=Set Date/Time 4=Walk Test 5=System Tools 1=SLC Tools 1=SLC Pinpoint 2=SLC Stats 3=SLC Addr Prog 1=Single device 2=Mltp device POWER EARTH FAULT SILENCED SILENCE ALARM SUPERVISORY TROUBLE RESET 1 4 7 2 5 8 0 3 6 9 ESC ACK DRILL ENTER SLC Program Terminals DWG #593-21 3-20 . Press ENTER to display Main Menu. Use the buttons on the device to set the address. they must be assigned a unique address. if the "R22" LED is not lit. To address devices from the Panel: 1. and press Enter to complete addressing device. The prompt “Enter key will Shutdown System” displays on LCD panel. 3. The SLC Addr Prog menu displays: 3=SLC Addr Prog 1=Single device 2=Mltp device Next. 2. Figure 21. press Power until it is reselected. Note: The "R22" LED is selected by default. There are two (2) methods to address devices: (1) You may use a hand-held address setting device or (2) Use the panel's System Tools – SLC Addr Prog option. Only authorized system users may access the System Tools options. 4.PFC-6030 • 5403595 • Rev a-2 • 10/11 Addressing SLC Devices Before devices can be programmed. yy Enter the applicable user code on keypad to continue. Press 5 to access System Tools (or press the down arrow to display 5=System Tools). Connect the device to the base on the hand-held address device or to the terminals with a pair of wires to connect modules. and 25-30) as necessary. Repeat steps for each device. #1-15.. Press 1 to select SLC Tools. Press 3 to select SLC Addr Prog. you must connect the device's cable to the panel's SLC PGM terminals (as shown below). You may sequentially address individual devices or groups of devices and assign different numerical ranges (i. Note: User code displays **** (asterisks) on LCD panel. 5. Press ENTER to shutdown (or press ESC to exit SLC Addr Prog).e. To address devices via a hand-held address device: 1. and emits beeping until acknowledged. The “Enter Code” prompt displays. yy The System Tools menu displays. The “Connect Device” prompt displays. The prompt “Connect Device” displays. 3. Addressing is completed when the panel emits a series of three (3) beeps. following prompts. Continue with next device. 2. New Addr: XX” prompt displays. Notes: 3. Connect device. yy Disconnect device. the next available address will be assigned to a different device and the DCM-4 will operate as a single point device. The “Found Address: xx” prompt displays.PFC-6030 • 5403595 • Rev a-2 • 10/11 For a Single Device: 1. yy Modify new address. Connect 1st device. Modify starting address. press 1 to address a Single device. 3-21 . yy Repeat steps. • • • • • • • • The “Start Address: XX” prompt displays. The “Addr = XX Next = XX Remove” prompt displays. The Class B DCM-4 requires 2 addresses. When configuring a Class B DCM-4. press 2 to address Mult device. if not already done. the “Found Addr: XX. and press ENTER. if this isn't done. if needed. Press ESC when finished. if needed. From the SLC Addr Prog menu. The prompt “Addr = XX” refers to the current device number. and the system beeps three (3) times when completed. yy The “Writing Addr: XX” prompt displays. Attach connector wires to SLC PGM terminals. or press ENTER to continue. From the SLC Addr Prog menu. When addressing is completed. 4. connect next device. Press ESC when finished. and “Next = XX” is the next sequential address number. and continue with next device. as needed. 2. The “Addr = XX Next = XX Remove” prompt displays. press the UP ARROW to skip the next sequential number. For Multiple Devices: 1. Disconnect the device. The expander adheres to the same circuit rating. Cooper Wheelock®.) NAC Wiring yy Outputs are supervised and regulated. To calculate the maximum line current impedance.PFC-6030 • 5403595 • Rev a-2 • 10/11 Notification Appliance Circuits Installation There are two (2) NAC circuits provided on the PFC-6030 rated as continuous 3 amps at 24 VDC. and may be configured for strobe synchronization with Potter/AMSECO. Potter #5403592. yy Type of NAC output is selectable. The NAC circuits may be configured for Class A or Class B. The panel has ground fault detection on the NAC circuits. or System Sensor® strobe devices. The impedance to ground for ground fault detection is 0 ohms. supervision and regulation as other circuits. yy The CA-6075 Class-A Expander may be programmed to allow for operation of the NACs. 3-22 . The Potter part number for the listed end of line assembly is #3005013 EOL Resistor Assembly. for this information. 2. Refer to the listing of compatible models located in the “NAC Compatibility Document”. Class B Wiring Example Notes: 1. yy Circuits are power limited. Figure 22. (Please refer to the Class A and B wiring examples located in this section. Gentex®. NAC Maximum Wiring Impedance Formula The maximum impedance is a function of the load placed on the circuit. use the following formula: (Alarm Current of Notification Appliances) x (Wire Resistance) < 3 Volts Examples of Class B and Class A Wiring follow. 3. SLC and P-Link. Note: If the power supply connected to the devices is power-limited.0A. Installation of Class A Card & Example of Class A Wiring guide pins 5050793 bracket #6-32 x 7/8 screws CA-6075 Class A Expander #6-32 x 1/4 screws DWG #593-27 3-23 . 4. The CA-6075 provides the terminals for both NACs and P-Link. 2. Figure 24. Install 5050793 bracket by inserting end tabs into slots on the PFC-6030 user interface. The dedicated trouble relay is a failsafe trouble relay that changes position anytime a trouble condition occurs. and Power Factor of 1. Relay Outputs Relays have a contact rating of 24VDC / 3. The Class A installation requires the use of the CA-6075. Once the card is installed. To install the Class A Expander: 1. Slide the CA-6075 Class A Expander over the two guide pins on the 5050793 bracket. These outputs are non-power limited and not supervised. the additional terminals are provided for the return loop of the NAC. Refer to the illustration below for more information. 3. CA-6075 Class A Expander The Class A installation requires the use of the CA-6075.Relay Output Wiring PFC-6030 • 5403595 • Rev a-2 • 10/11 The panel has three (3) dedicated common relays. Secure the CA-6075 to the 5050793 bracket using two (2) #6-32x1/4 screws provided. the additional terminals are provided for the return loop of the NAC. Notes: 1. Secure the 5050793 bracket to the panel using the #6-32x7/8 screws. 2. Once the card is installed. 5. Make sure the CA-6075 is fully engaged with the connector on the PFC-6030. then the outputs are power limited. Only 1 CA-6075 Class A expander may be installed per panel. 125VAC / 3A. Figure 23.0. Remove two (2) #6-32x7/8 screws from the panel. 500 feet. Configuration Characteristics yy P-Link current rating is one (1) amp. Up to thirty-one (31) of each device type are allowed on the P-Link bus. such as remote annunciators.PFC-6030 • 5403595 • Rev a-2 • 10/11 P-Link Devices Accessory devices. Maximum Wire Resistance Formula The maximum resistance is based on the load placed on the circuit. use the following formula: (Total Annunciator Alarm Current) x (Wire Resistance) < 6 Volts Figure 25. RA-6075 Class B Wiring Example 3-24 . yy The maximum wire length is 6. are connected to the main control panel utilizing the four-wire P-Link bus for power and communication. Devices can be connected using a Class B or Class A wiring style (examples shown below). To calculate the maximum wire resistance. yy P-Link voltage rating is 24 VDC. PFC-6030 • 5403595 • Rev a-2 • 10/11 Figure 26. Use the chart below to reference Dip Switch Settings: Annunciator Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Dip Switch Settings SW-1 On Off On Off On Off On Off On Off On Off On Off On Off SW-2 Off On On Off Off On On Off Off On On Off Off On On Off SW-3 Off Off Off On On On On Off Off Off Off On On On On Off SW-4 Off Off Off Off Off Off Off On On On On On On On On Off SW-5 Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off On Annunciator Address 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Dip Switch Settings SW-1 On Off On Off On Off On Off On Off On Off On Off On SW-2 Off On On Off Off On On Off Off On On Off Off On On SW-3 Off Off Off On On On On Off Off Off Off On On On On SW-4 Off Off Off Off Off Off Off On On On On On On On On SW-5 On On On On On On On On On On On On On On On 3-25 . RA-6075 Class A Wiring Example P-Link Addresses Each P-Link device has a five position dip switch which is used to program the device address ranging from one (1) to thirty-one (31). for convenience the UD-1000 is typically programmed as device ID #01. An RJ31X jack can be installed to provide the connection to the telephone lines.) Figure 27. 3-26 . The UD-1000 DACT communicates using the SIA-DCS or Ademco Contact ID protocols. it is designed to be mounted on a flat non-condensing surface or electrical box. a patch cable between the RJ31X jack and the built in RJ-11 jacks on the UD-1000 provide a convenient connection method.PFC-6030 • 5403595 • Rev a-2 • 10/11 Installing Remote Annunciators The RA-6075 Remote Annunciator provides the same display and control capabilities as the main control panel’s built in display. Once the communication is complete. In order for the DACT to work properly. it must be installed on a plain old telephone service (POTS) or equivalent as deemed by the authority having jurisdiction. The address must be set in the range of one to thirty-one to be recognized by the panel. The UD-1000 Digital Alarm Communicator Transmitter provides connections for two (2) phone lines for communication to a monitoring station. Address Settings The RA-6075 address is set by dip switch S1 located on the back of the annunciator. The UD-1000 automatically monitors each phone line for voltage and has the ability to seize the line and connect with a remote receiver. The UD-1000 must be installed prior to any other telephone equipment in the building to ensure proper operation. The DACT must be installed before any other equipment to ensure it can seize the line and disconnect any other lines. the DACT will hang up the phone line. Only the RA-6075 Remote Annunciator should be used on the PFC-6030 FACP to ensure that the display operation works correctly. (Refer to chart on the previous page for P-Link DIP switch programming. Only one UD-1000 is allowed per main control panel. The DACT is provided with an RJ-11 jack for each phone line. The wire conductors connecting the DACT to the phone system should be 26 AWG or larger. RA-6075 Class A (back panel view) DIP SWITCH A B + - DWG #593-31 Installing the DACT Phone lines are high voltage and should be run in a separate conduit from other circuits. ) Figure 29. Dip Switch Location The UD -1000 is connected to the P-Link bus and must be programmed with an address between one and thirty-one for proper operation. P1 connector DWG #593-32 The UD-1000 is supplied with a four-wire cable (P/N 5210514) to connect between P1 on the UD-1000 and P4 on the main panel PC board. (Refer to the P-Link Dip Switch Settings chart shown earlier in this section.PFC-6030 • 5403595 • Rev a-2 • 10/11 Figure 28. UD-1000 DACT Installation P4 connector screw Jumper connection Slides in guides under main board. Dip Switches Location Diagram Line #2 Line #1 Dip Switches DWG #593-33 3-27 . arrow keys. The LCD also provides access to the Main Menu for daily system operations and specific programming functions (refer to “Section 5: Programming – Menu Functions” for details on these topics). and the numeric keypad. status LEDS. status information. trouble conditions. 4-28 . LCD Display The LCD panel displays the standard Start-up menu as shown below.. PFC-6030 Control Panel Annunciator LCD Display Arrow Keys Status LEDs Numeric Keypad Function pushbuttons Note: Authorized system operators must use a key to open the outer door of the cabinet.e. Figure 30. Control Panel Basic Operation The control panel is comprised of a two (2) line x 16-character LCD display panel. providing important feedback to system users. i. Note: You may customize the Start-up screen to display a specific job site name or other relevant descriptive text. which includes the status LEDs. function pushbuttons.PFC-6030 • 5403595 • Rev a-2 • 10/11 Section 4: Operation This section provides an overview of the control panel’s basic operations. Refer to the figure below for an example. or input changes. A description of each component is included in this section. pushbutton function keys. LCD Start-Up Screen Up to thirty-two (32) characters of information displays. system messages. and a Control Panel Menu Tree quick reference sheet. Figure 31. they are located on the numeric keypad. using the arrow and Enter keys to select a function. Displays the Main Menu or selects the current menu option. Table 6: Menu Navigation Keys Pushbutton Description Moves/scrolls up or down through menus. Returns to previous menu or backs up to previous screen. The table shown below provides a summary of the navigation keys. Figure 32. Scrolls to the left or right to display details. if any. Note: The blinking “” indicates the current menu option. The Enter and Esc keys may also be used to navigate through menus.PFC-6030 • 5403595 • Rev a-2 • 10/11 Menu Navigation Keys The arrow keys allow you to scroll or move through the control panel menus. Note: When the LCD panel displays a LEFT and/or RIGHT arrow. Alternatively. Numeric Keypad The numeric keypad allows you to enter user codes when required to access restricted functions. the numbers may be used to quickly select menu options vs. of current menu item. this indicates more information may be viewed. Control Panel Numeric Keypad 4-29 . PFC-6030 • 5403595 • Rev a-2 • 10/11 Function Pushbuttons The four (4) function pushbuttons are used when system alarm / trouble conditions occur or to perform a fire drill. A fault condition is present. 4-30 . Status LEDs The control panel’s LEDs communicate system conditions by illuminating and/or flashing the applicable green. red or amber indicators. A ground fault is present. An alarm device is active. LED will extinguish. Press to begin a fire drill. Press to reset panel to normal condition. Figure 34. Control Panel Pushbuttons The table below provides a brief summary of the pushbuttons: Table 7: Control Panel Pushbuttons Pushbutton Description Press to acknowledge the currently displayed condition. Note: If power is absent for more than 5 seconds. Control Panel Status LEDs Table 8: Status LEDs LED Type Power Alarm Earth Fault Supervisory Silenced Trouble LED Color/Action Steady Green Flashing Red Flashing Amber Flashing Amber Steady Amber Flashing Amber Description Power is present. These are described in the table below. A supervisory condition is present. Figure 33. A fault condition has been silenced. Press to silence all outputs programmed as silenceable and buzzer. press “3” to select “Set Date/Time” from the Main Menu. For example. PFC-6030 • 5403595 • Rev a-2 • 10/11 Control Panel Menu Tree This section provides a reference to menu options as they appear on the LCD panel. Gateway 7=Alt. enter the menu selection number on the keypad to select a function. 4-31 . MAIN MENU 1=View History 2=Enable/Disable 3=Set Date/Time 4=Walk Test Select Device Internal SLC Internal PWR MAIN MENU 5=System Tools 6=Programming 7=Data Transfer Esc=Exit 1=SLC Tools 2=Point Control 3=Ethernet Status 4=DACT Test 5=DACT Reset 6=Erase History 7=Lamp Test 8=App Revisions 1=LEARN Mode 2=Panel Default 3=IP Settings 4=Dflt ID/Pswd 5=Prog ID/Pswd Esc=Exit Select Data 1=Remote Access 2=E-mail Det Stat 3=E-mail History 4=E-mail Config 5=E-mail Test 6=Server Status Esc=Exit 1=SLC Pinpoint 2=SLC Stats 3=SLC Addr Prog 1=Username 2=Password Esc=Exit 1=Single Device 2=Mltp Device Ethernet Options 1=DHCP Settings 2=Default IP 3=Default Gateway 4=Default Subnet 5=Alternate IP 6=Alt. Subnet Esc=Exit TIP: To save time. Appendix F also provides a copy of the Control Panel Menu Tree for reference. provides an overview of the programming process. DACT. scheduling holidays. 15 sec. installers. 1 minute. Table 9: Programming Options Topic Misc Misc Misc Misc Misc Misc Misc Misc Misc Misc Misc Misc Misc Misc Misc Feature or Option Idle LCD Message Display Events SLC Blink Alarm Verification Time Waterflow Delay AC Report Delay DH Low AC Dropout Delay Auto Test Time Strobes Active When Silenced 50 Hz AC Display AM/ PM Time Zone DST Enabled DST Start DST End Permitted in UL (Y/N) Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Possible Settings Yes/No Initial Event Newest Event Normal/Slow/Off 0-60 sec 0-255 sec 0-30 Hours No delay. and addresses how to use the two programming methods: (1) the LEARN function. certain programming features or options must be limited to specific values or not used at all as indicated below. 5 minute Time of Day Yes/No Yes/No AM/PM. In order for the product to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems. displaying events. Please refer to this section to learn how to navigate within the software. Programming Options To users. access and modify programming settings. authorities having jurisdiction. This section also includes procedures on uploading and downloading configuration data using the panel configuration software. such as the system clock and day/night mode sensitivity settings. UL 864. remote annunciators and a Class A card). and programming optional modules (i..e. 24 Hour 24 Time Zone Selections Yes/No Month/Day Month/Day Setting(s) Permitted in UL864? All settings allowed Initial Event All settings allowed All settings allowed 0-90 sec 1-3 Hours All settings allowed All settings allowed All settings allowed All settings allowed All settings allowed All settings allowed All settings allowed All settings allowed All settings allowed Comment Auto display of first event For UL864 use 1-3 Hr 5-32 . and other involved parties: This product incorporates field-programmable software. and (2) the remote computer programming process.PFC-6030 • 5403595 • Rev a-2 • 10/11 Section 5: Programming This section addresses programming options and their parameters. 1%-3. Zone Module (CIZM) Mini Contact Mod (MCM) Single Contact Mod (SCM) Dual Contact Mod (DCM) Mon.PFC-6030 • 5403595 • Rev a-2 • 10/11 Table 9: Programming Options Topic Feature or Option Permitted in UL (Y/N) Possible Settings Alarm Supervisory Positive Alarm Sequence Auxiliary Fire Drill System Alarm System Supervisory System Trouble 1-10 Yes/No Yes/No Yes/No Yes/No 0-300 Sec Yes/No Yes/No Constant ANSI Temporal March Code Double Time 1.1%-3.5% 1. Output Mod (MOM) Twin Relay Module (TRM) Sounder Base (ASB) Relay Base (ARB) Yes/No Yes/No Setting(s) Permitted in UL864? Comment Zone Zone Type Y All settings allowed Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Alarm Count Silenceable Silence Inhibit Auto Silence Auto Unsilence Restore Delay Latching Local Output Pattern Day Sensitivity Night Sensitivity Fixed Heat Setting Combo ROR/ Fixed Setting Y Y Y Y Y Y Y Y Y Y Y Y Y All settings allowed All settings allowed All settings allowed All settings allowed All settings allowed Full range allowed All settings allowed All settings allowed All settings allowed Within listed range of sensor Within listed range of sensor Within listed range of sensor Within listed range of sensor Full range allowed Full range allowed Full range allowed All settings allowed SLC Point Function Y All settings allowed Specifies use/type of SLC device SLC Point SLC Point Alarm Verif Supervisory Y Y All settings allowed All settings allowed 5-33 .5% 135̊F-185̊F 135̊F-174̊F Photo Detector (PSA) Photo Duct Detector (DSA) Photo/Heat Detector (PSHA) Fixed Heat Detector (FHA) Combination Fixed / ROR Heat Detector (RHA) Conv. PFC-6030 • 5403595 • Rev a-2 • 10/11 Table 9: Programming Options Topic Feature or Option Permitted in UL (Y/N) Possible Settings Potter/Amseco Sync Gentex Sync System Sensor Sync Wheelock Sync Constant Output Resettable Output Door Holder Output ANSI Output City Tie Output Y Full listed range of smoke detector Any time of day Setting(s) Permitted in UL864? Comment NACs Function All settings allowed Specifies use of NAC circuit(s) Day/Night Smoke Sensitivity Daily Test Call All settings allowed Up to 50 holidays where day mode is not active. DACT Y All settings allowed 5-34 . Alternates between line 1 and 2 if line 2 is enabled. 4. module.e. Software Installation It's easy to install the PFC-6030 software and requires only a few minutes to complete. yy You may change the location of the application files..) The Programming Cycle The following is a recommended approach to programming the system: 1. The panel configuration software allows custom programming and configuration for all points via a network or remote computer. drag and drop. To install the software: yy Access the Potter website at www. right click to display short cut menus. The software’s flexibility enables you to effectively program individual and/or groups of devices. assigns a name and selects the applicable device type (i. 3. By using the system software.com. 5-35 . these are only recommendations. the program automatically creates a shortcut icon on your desktop for easy access. 5.pottersignal. you will realize the power and flexibility of the PFC-6030 system. The system software is compatible with XP.. etc. and go to the "Fire Systems – Installation Tools" to download. 7.PFC-6030 • 5403595 • Rev a-2 • 10/11 Programming Overview The LEARN function is available through the control panel.0 Windows™ Operating Systems.e. yy The default installation directory is: C:\ProgramFiles\Potter\Pottter Fire Panel Programmer. Once done.). and is an efficient way to automatically configure all system devices. (Please refer to “Panel Software Overview” and “Mapping Zones” in this section for details on these procedures. you may fine-tune device behavior characteristics or create mapping zones for a more sophisticated fire protection system. The system configuration mirrors a basic fire protection system where all inputs and outputs are a one-to-one relationship. 6. LEARN detects all connected devices. 2. Install Software Address and Install SLCs Run LEARN Connect Ethernet Cable Upload Data to Computer Program the System Download Configuration File Note: This approach may eliminate programming errors. Vista and 7. however. Several examples in configuring a basic fire system are provided later in this section under the “System Programming” heading. At the click of a mouse. sensor or P-Link device). and incorporates conventional shortcuts and features (i. Press 1 to save changes. • Press Enter to accept or Esc to discard. • Press 1 to select LEARN.) Only authorized users may access this function. • Use down arrow to scroll through results by device type: 1=P-Link Found 2=P-Link Removed 3=Pts Found 4=Pts Removed 5=Pts Changed Esc=Exit Note: The abbreviation “Pts” refers to addressable SLC points. Results are grouped by device type. the “Accept confirmation” prompt displays. The "Enter Code" prompt displays. press the Enter button to display the Main Menu. press 2 to discard changes.) To run the LEARN mode: 1. Control Panel Ethernet Port Ethernet port POWER EARTH FAULT SILENCED SILENCE ALARM SUPERVISORY TROUBLE RESET 1 4 7 2 5 8 0 3 6 9 ESC ACK DRILL ENTER SLC Program Terminals DWG #593-21 5-36 . From the control panel.PFC-6030 • 5403595 • Rev a-2 • 10/11 LEARN Programming The LEARN mode enables you to efficiently configure all connected. Connect Ethernet cable to port as shown below. If no changes are detected. (Refer to the “Configuring Points” and “Mapping Zones” sections for details. The "SLC Initializing" prompt displays. LEARN generates a list of all points. • Enter the user code as prompted. 2. • Select Esc when finished reviewing results. and the system begins the initialization process. Connect cable to the Ethernet port on network (or directly to the panel if not using a network). Figure 35. addressed input and output devices. Connecting a Computer to the Panel via a Network: 1. Press Esc to exit programming menu. The system prompts to save or discard file. • Press 6 to select Programming. Once this is achieved. 4. (Refer to Section 3: Installation – Addressing SLC Devices. If your PC connects directly to the panel. • If option 1 is selected. The “1 Learn” prompt displays. 3. any procedural differences are noted throughout. you may program your system using the panel configuration software. which may be viewed through the Points and Zones functions on a remote computer. for detailed instructions. 2. the prompt “No changes” displays. Note: These instructions are relevant to all system configurations. Connecting the Computer and Panel This section provides instructions on setting up connectivity between a laptop or networked computer and the control panel. followed by the "Private IP" message (the "Private IP" message is not shown here).27” shown above represents an example of a panel’s IP or identifier used for illustration purposes only. 3.5. This indicates cable is disconnected at panel or network (computer) port. Write down the IP address. the message “Ethernet Lost” displays on panel. Note: If Ethernet connectivity is lost.PFC-6030 • 5403595 • Rev a-2 • 10/11 The following series of messages display on the LCD: Note: If your PC is connected directly to the panel. 5-37 . Note: The number “10.0. the "Obtaining IP" message displays for approximately 45 seconds. it is required to transfer programming data between the panel and the computer. The “IP configured” and “IP address” prompts alternatively display until configuration is completed. The panel’s IP is unique to each computer / network. The Transfers region is located at the bottom of the Programmer window and lists all completed transfers. This area displays transfer details. Figure 36. The "Transfer" icons are located at the top of the Programmer window. Note: Double-click anywhere on the transfer record to view details. You may also access the “Transfer” shortcut menu from this location to select any of the transfer functions. Uploads configuration file from panel to computer. Example of Programming Window Showing Transfer Icons and Transfer Section The "Transfer" window displays all completed transfers.PFC-6030 • 5403595 • Rev a-2 • 10/11 Transferring Data This section provides step-by-step instructions for completing uploading and downloading data transfers. 5-38 . Uploads history events file from panel to computer. including their date and time. Uploads detector "sensitivity" status file from panel to computer. Table 10: Transfer Functions Icons Description Downloads configuration file from computer to panel. which are briefly described below. and additional programming changes are made at a later date. 5-39 . Notes: • If you do not name the file. Enter the configuration filename in the “Filename” field or leave blank to Autoname. Verify that Upload is selected in the “Transfer Type” field. Click the Upload Configuration File to Computer icon or right click from “Transfers” region as shown below: Figure 37. The Transfer dialog box displays. Figure 39. if necessary. the program automatically names it using the transfer type and date stamp as the file name. 2. click the Browse button to locate the file name to replace the old file with the updated configuration changes. To upload programming changes to computer: 1. Example of Transfer Shortcut Menu Right click anywhere in the transfer window to display the shortcut menu. 3. Example of Transfer – Upload Window Enter file name or leave blank to auto-name.PFC-6030 • 5403595 • Rev a-2 • 10/11 Uploading from Panel to Computer is used to upload the configuration file from the panel to the The Upload Configuration File to Computer transfer icon computer once the LEARN function is completed or whenever devices are added or removed from the panel. Figure 38. Note: Click the "Add" option from the shortcut menu to choose the transfer type. Example of Transfer – Upload Dialog Box Click here to choose applicable transfer type. • Once the file has been saved. please refer to “Appendix B: Modem Connectivity Setup”. Downloading Configuration File to Panel The Download Configuration File to Panel icon allows you to copy all programming changes to the panel. The “ENTER CODE” prompt displays. Enter IP address or panel name in the “Transfer Via IP” field. 5. Notes: • Be sure to "Enable Remote Access" at the panel before choosing this option. At control panel. 4. Notes: • To capture your panel’s unique IP address. Enable Remote Access To enable remote access: 1. disconnect the Ethernet cable from panel. The message “Ethernet Lost” displays indicating connectivity is lost. the remote access will “time out” after thirty (30) minutes if contact is not established. 2. The Transfers region displays the uploaded file.PFC-6030 • 5403595 • Rev a-2 • 10/11 4. If your PC is directly connected to the panel versus a network. Be prepared to write down address. • All points detected during the LEARN process have been uploaded to the panel configuration software. The Select Data option displays. 5. • If you are connecting via a modem. this step is not necessary. Enter the user code to continue. Example of Transfers Download Results • Double-click on the transfer file to display results. and reconnect cable. Figure 40. 5-40 . you will receive an error message when attempting to download data to the panel. Note: Details on viewing and configuring points are addressed in detail later in the “System Programming – Configuring Points” topic. 3. Press 7 to select Data Transfer. Press 1 to select Remote Access. press ENTER to display the Main Menu. • Verify that the Remote User Name and Password match the panel’s user name and password. Press ESC to return to Main Menu. If they do not match. Click OK. Note: Once enabled. PFC-6030 • 5403595 • Rev a-2 • 10/11 File Save / Save As Once programming has been completed, save your configuration file using either the File – Save or File – Save As function. An audit is performed checking for rule violations; and, if errors are encountered, you may choose to either save with errors or cancel the save operation. Figure 41. Example of Save Panel Dialog Box Notes: 1. All site specific configuration data is stored in the panel’s non-volatile memory. 2. The next time you make programming changes, you may overwrite the original configuration file with changes. If you choose to do this, you will lose the original programming report information. 3. The panel configuration file has a .fpcf file extension. Audit Errors The Audit Error - Save Anyway? dialog box displays if programming errors are encountered when saving the configuration file. You may choose to save the file with errors; however, you cannot upload the data until all errors are corrected. Figure 42. Example of the "Save anyway?" Dialog Box 5-41 PFC-6030 • 5403595 • Rev a-2 • 10/11 Downloading a Configuration File To download the configuration file: 1. Click the Download Configuration File to Panel icon The Transfer dialog box displays. Figure 43. Example of Transfer – Download Dialog Box or right click from the “Transfers” region, then click “Add”. 2. Verify that Download is selected in the “Transfer Type” field. 3. Enter the file name in the “Filename” field or click the Browse button to select file name. 4. Enter the IP address in the “Transfer Via IP” field. Figure 44. Transfer - Download Dialog Box Note: To capture the panel’s unique IP address: 1. Disconnect the Ethernet cable from panel. 2. The message “Ethernet Lost" displays indicating connectivity is lost. 3. Reconnect the cable, and write down the IP address shown. 5. Click OK. The Transfers window displays the transfer progress. Figure 45. Example of Transfers Window Showing Download Completed 5-42 PFC-6030 • 5403595 • Rev a-2 • 10/11 Uploading History Events & Detector "Sensitivity" Status Reports The Upload History File to Computer and Upload Detector "Sensitivity" Status to Computer icons allow you to view valuable information that can be essential when analyzing system operations. These reports may also be scheduled to be sent to authorized e-mail addresses. Refer to the "System E-mail Functions" topic located later in this section for details on programming these e-mail reporting options. History Reports The “Event History” transfer option creates a report of all events held in the panel’s buffer. Up to 1,000 events are held in the buffer at one time. This information may be used to troubleshoot errors or to assess ways to improve the system configuration. To transfer event history information: 1. Click the Upload History File to Computer icon The Transfer dialog box displays. or right click from “Transfers” area, and click "Add". 2. Verify that History is selected in the “Transfer Type” field, and click OK to display results. Figure 46. Transfer Window Results 3. Double-click file to view results. Figure 47. Example of Transfer Results Window 4. Click the close button to close report. Note: Refer to "System E-mail Functions - Receiving E-mail Status Reports" located in this section for a sample of a History Events Report sent via e-mail. 5-43 Click OK. 5-44 .Receiving E-mail Status Reports" located in this section for a sample of a Detector "Sensitivity" Status Report sent via e-mail. Example of Detector "Sensitivity" Status Report Completed Note: Refer to "System E-mail Functions . 4. 2. Figure 49. Click the close button to close the report.PFC-6030 • 5403595 • Rev a-2 • 10/11 Detector "Sensitivity" Status Reports The Upload Detector Status File to Computer icon allows you to create reports showing sensitivity related SLC sensor information. To transfer detector "sensitivity" status information: 1. The Transfers window displays results. Figure 48. and choose "Add". This information may be used to troubleshoot detector issues. Click the Upload Detector Status File to Computer icon 3. Verify that Detector Status is selected in the “Transfer Type” field. 5. Example of Transfer Status or right click from “Transfers” region. Double-click file to view results. It addresses navigating through the program windows. using Window’s conventional editing techniques and other program shortcuts to efficiently configure your system. Example of Panel Menu Information 5-45 . Please refer to the examples below. Window Regions / Areas What you select from the Panel window located on the left determines the information displayed on the right. Panel Menu Figure 51. Figure 50. The selected panel function is highlighted which helps direct your eye to the related information shown on the right. understanding the purpose of icons and program features.PFC-6030 • 5403595 • Rev a-2 • 10/11 Panel Software Overview This section gives you an overview of the Panel Configuration Software. point to window “tab” to redisplay (Window Tab is explained below. • Click the minus sign to collapse. such as auto hide. • Point to “Tab” to display window. Icon changes to (insert window autohide if window is hidden. Example of Zone tab: Tab Window “Tab” Available in Zones and Points windows only. • Auto Hide – window is hidden when cursor is moved and “tab” displays as window placeholder. There are others that are unique to the panel software.) Shortcut to hide a window. • Dockable – default window position. available for specific windows only. Note: “Tab” name is specific to hidden window. Auto-Hide • • • Click to hide window. Click to unhide and dock window. right-click title bar to reselect dockable. and window position which are summarized in the table below: Table 11: Panel Configuration Icons Name Icon Description/Function Located in the upper right region of some windows. such as the close button and scroll bars. • Click the plus sign to expand.PFC-6030 • 5403595 • Rev a-2 • 10/11 Program Icons The panel software uses several standard Windows’ icons. • Point or click in another window to hide. window is “locked” in place. Example (Points window): Expand / Collapse 5-46 . Click the icon to choose an option: • Floating – window floats over other windows. Window Position Displays if window is hidden. Class A Card Annunciators SLC Loop Power Supply Add or remove Class A card. and other related sensitivity options. Define and view all addressable and non-addressable points. such as alarm verification time. Enable Day/Night Sensitivity. View power supply details. Define and configure zone’s characteristics and mapping points. and select type of report(s) to send to each e-mail addressee. View SLC Loop details. Add or remove DACT module/appliance. Establish relationships between multiple zones. 5-47 . setup e-mail addresses. Details for these options are provided on the following pages. and set access rights. Create up to ten (10) user codes and passwords.PFC-6030 • 5403595 • Rev a-2 • 10/11 Programming Functions Overview The table below gives you a snapshot of the menu order along with a brief description of each. Allows site specific information to be entered. and door holder low AC dropout delay. Allows software’s general panel settings to be customized. Add or remove Remote Annunciators. Table 12: Programming Menu Overview Menu Option Remote Access Code Job Details General Options Zones Cross Zones Points Sensitivity E-mail Reporting Users LAN Settings Dialer Description The remote access “User Name” and “Password” displays. Configure Ethernet connectivity options. Schedule e-mail reports by day and time. setup Holiday schedule. they can be changed to ensure that only authorized personnel can transfer data to and from the panel. 2. Figure 52. Remote Access Code Screen Notes: 1. Figure 53. The remote user name and password must match the panel’s user name and password. Example of the Panel Configuration Screen User Name / Password The default user name and password is “Potter” as shown below. The remote access user name and password may be changed to increase security on the system.PFC-6030 • 5403595 • Rev a-2 • 10/11 Remote Access Code The Panel Configuration window displays the remote access user name and password on the right section of the screen (refer to the example shown below). 5-48 . Job Details Window 2. To enter site information: 1. such as company name. Click in each applicable field to enter information. Please refer to the figure shown below. idle message. Figure 55. General Options The General Options window contains a variety of general system settings.PFC-6030 • 5403595 • Rev a-2 • 10/11 General System Functions Job Details Site specific information. such as the panel’s default name. and the time an Autotest will be sent to the monitoring station. General Options Window 5-49 . The Job Details window displays. Figure 54. Note: You may also press the TAB key to move to next field. This information is stored in the panel and is used to identify the panel when using e-mail reporting options. Click the Job Details program option. address and phone numbers may be entered in this window. create a “Holiday Schedule”. which enables night sensitivity mode on those dates. 5-50 . To enable day/night sensitivity and setup holidays: 1. Example of the Day/Night Sensitivity Enabled 2. Be sure to enable to use this feature. Note: The Day/Night Sensitivity option is not selected or enabled by default. 5. Adjust start and end times. establish the starting and ending times for “Night” sensitivity. Figure 56. Enter holidays in the “Month/Day” field. Click in applicable days of the week selection boxes to select or deselect. and choose the days of the week that the site is normally occupied. as shown: Note: You may enter up to fifty (50) holidays in the “Holiday Schedule” field. if needed. Click in “Enable Day/Night Sensitivity” selection box to enable.PFC-6030 • 5403595 • Rev a-2 • 10/11 Day/Night Sensitivity Mode and Holiday Scheduling The Sensitivity option allows you to enable the “Day/Night Sensitivity” feature. Click on the Sensitivity option. 4. 3. The Sensitivity window displays. 5-51 .PFC-6030 • 5403595 • Rev a-2 • 10/11 Users The Users option allows you to create up to ten (10) user profiles. Each profile may have different access rights. Example of Users profile Window 2. To create a new user: 1. Repeat steps for up to 10 users. Click in the appropriate access field selection boxes to grant access to that feature. Click on the Users option. 3. The User’s Code window displays. Figure 57. Double click in the “Name” field to enter a descriptive user name. which controls the panel functions a user may access. if needed. Note: The access rights for the “Default Access” user code can be modified if needed. 4. E-mail Reporting Window Event History and Detector Status reports will be sent based on the weekly schedule. Panel Serial Number Location Panel Serial Number 5-52 . They are intended to be used as a convenience function. You must make a notation of your panel's outgoing e-mail address in order to send e-mail requests remotely. After the “E-mail Reporting” section is completed and downloaded into the panel. if the user has a valid e-mail address programmed on the "E-mail Reporting" window. time or day of the month. The panel address is structured as: PFC60XXXXXXXXXX@potterlink. Troubles. Figure 59.com where "PFC60XXXXXXXXXX" refers to the “panel serial number". Note: Outgoing panel e-mails are routed through a dedicated Potter server. Up to twenty (20) e-mail addresses may be programmed on this screen. to the e-mail addresses designated on the "E-mail Reporting" window as shown below. System E-mail Functions The PFC-6030 comes with built-in e-mail capabilities. Alarm. E-mail communications should NOT be used as a primary means of reporting emergency information. Trouble. On-demand reports can be requested directly from the panel's "Data Transfer" function or remotely from a PC. Supervisory and Test events. The serial number is the same as the NetBIOS name. The panel automatically sends status e-mails. Figure 58. The panel is capable of sending automatic and on-demand reports because it has a designated outgoing e-mail address comprised of its model and serial numbers. and is located on the panel as shown below. time and day of the month indicated here. including Alarms.PFC-6030 • 5403595 • Rev a-2 • 10/11 System e-mail communications and functions are intended for informational reporting purposes only. Supervisory and Test Events are sent immediately as they occur! Event History and Detector "Sensitivity" Status reports may be scheduled to be sent on specific days of the week. the panel will start sending e-mails according to programming. They are intended to be used as a convenience function. This is usually accomplished by installing an Ethernet drop near the panel.. Outbound Connectivity Inbound Connectivity Connecting the Panel to a Network In order to use the e-mail feature.. P-Link E-mail Notification Requirements The following table lists the necessary hardware and Internet connectivity requirements to use P-Link functions.or Set the IP address using the Static IP function 5-53 . Port 25 for SMTP Port 110 for POP3 None required or utilized. Table 13: P-Link E-mail Notification Requirements Item Hardware IP Address Protocol Requirement 10/100 Mbps Ethernet Network DHCP or Static IP (factory default is DHCP) Must have outbound access to Internet (mail server connections only). The IP address can be set one of two ways: • The panel has a built in DHCP (Dynamic Host Configuration Protocol) and will ask for an IP address from the “Host Computer”. Figure 60. E-mail communications should NOT be used as a primary means of reporting emergency information. such as DACT and e-mail notification. the panel must be connected to a network with Internet connectivity. • The installer or the Network Administrator may set the IP address using the software's Static IP function. Setting the IP Address Set the IP address using the DHCP function.PFC-6030 • 5403595 • Rev a-2 • 10/11 System e-mail communications and functions are intended for informational reporting purposes only. E-mail Report Programming To setup History and Detector "Sensitivity" Status reports schedule: 1. if you wish reports to be sent on a specific day of each month. The E-mail Reporting window displays. 2.fpcf) Allows user to send a test e-mail Allows e-mail server status to be verified 5-54 . Select a day of the month. E-mail Reporting showing Enable E-mail Request Important Note: The "Enable E-mail Requests" option must be selected in order for the panel to respond to an e-mail addressee requesting an ondemand report. Select the Data Transfer (Menu Option 7) on the panel menu.PFC-6030 • 5403595 • Rev a-2 • 10/11 System e-mail communications and functions are intended for informational reporting purposes only. Select the "Enable E-mail Requests" option if the e-mail addressee may request reports from the panel. 4. To setup addresses and select events and/or reports: 1. 3. the panel will ignore an e-mail request for an on-demand report. Adjust time. They are intended to be used as a convenience function. An “” displays in each selected report type. if necessary. Figure 61. 4. Note: Be sure to select each report type in the next E-mail section for each recipient you wish to send these reports. E-mail communications should NOT be used as a primary means of reporting emergency information. Select one of the transfer options as described below: Option 1=Remote Access 2=E-mail Det Stat 3=E-mail History 4=E-mail Config 5=E-mail Test 6=Server Status Table 14: Data Transfer Options Description Used to enable remote access Allows user to e-mail a detector "sensitivity" status file Allows user to e-mail a history file Allows user to e-mail a panel configuration file (. Click in the days of the week’s selection box to choose the days that the History and Detector Status report(s) will be sent. Click on the E-mail Reporting option. if needed. In the E-mail address section. Note: If "Enable E-mail Requests" is not selected. enter up to twenty (20) e-mail addresses. E-mail Sent from Panel To send a report email from the panel: 1. 2. 2. as shown below. 3. Select each type of event(s) and/or report(s) you wish to send to the applicable e-mail address. Default Outgoing E-mail Address Use the "Default" outgoing e-mail address. 3. In the "To" field. enter the panel's e-mail address as shown below. Example of Keywords in E-mail Subject Enter keyword(s) in Subject field. 5-55 . Select one or more e-mail address using one of the following options: • Choose "Use Default” to select the address entered in “General Options” (as shown below). • Choose “Specify New” to enter additional e-mail addresses. Example of the General Options Window . They are intended to be used as a convenience function. if needed. (Refer to the "Panel Serial Number Location" shown earlier in this topic. 2. • Choose "Browse List" to scroll through and select one or more e-mail addresses entered in the “E-mail Reporting” section of the software. Open or create a new e-mail. E-mail Report Requested from PC To request a report from a remote PC: 1.) Figure 63.PFC-6030 • 5403595 • Rev a-2 • 10/11 System e-mail communications and functions are intended for informational reporting purposes only. Figure 62. E-mail communications should NOT be used as a primary means of reporting emergency information. • Configuration to send a current configuration file back to sender. There are no restrictions on contents entered into the body of the e-mail. Important Reminders! • The person sending the e-mail must be added to the e-mail list in the “E-mail Reporting” section of the software as shown below. E-mail Reporting Window Sender's e-mail must be in the e-mail list and the Enable E-mail Requests box must be checked. They are intended to be used as a convenience function. when using the panel menu Data Transfer option. • Subscribe to activate e-mail settings for the sender. E-mail communications should NOT be used as a primary means of reporting emergency information. Note: You may choose not to select specific event types or reports for e-mail addressees.PFC-6030 • 5403595 • Rev a-2 • 10/11 System e-mail communications and functions are intended for informational reporting purposes only. Then scroll through e-mail addresses and select one or more recipients. In the “Subject” field. • The “Enable E-mail Requests” option must also be checked for the sender to receive e-mails when requested from the panel or a remote PC. Note: Keywords are NOT case sensitive and more than one can be entered in the subject line of the e-mail. • Status to send a current detector "sensitivity" status report back to sender. If the sender is not in the list. choose Browse List. the panel will not respond. enter one or more of the following keywords: • History to send a current event history report back to sender. Figure 64. If so. 5-56 . • Unsubscribe to stop the current e-mail settings for the sender until panel is reset or that e-mail address sends a “Subscribe” to the panel. 3. 4. They are intended to be used as a convenience function. The events are listed after the “Job Details” information.txt) Refer to Table 17 – Zone Attributes in this Section for an explanation of Day/Night Sensitivity settings. Example of a Detector "Sensitivity" Status text file (. Trouble events) e-mail is received. Example of Job Details in System Status E-mail Job Details display here When a history or detector "sensitivity" status e-mail is received it contains two attachments: • A text file (. If nothing is entered in the software. event type. the body of the e-mail contains the information entered in the “Job Details” section of the software (as shown below). They are formatted with a date/time stamp showing when the event occurred. Supervisory.csv) file Figure 66.PFC-6030 • 5403595 • Rev a-2 • 10/11 System e-mail communications and functions are intended for informational reporting purposes only. the body of the e-mail will only indicate the events that occurred. E-mail communications should NOT be used as a primary means of reporting emergency information. Receiving E-mail Status Reports When a system status (Alarm. 5-57 . Figure 65.txt) • A comma separated values (. and the event description or the point information. Figure 67.txt) & History Comma Separated Value file 5-58 . E-mail communications should NOT be used as a primary means of reporting emergency information. Examples of a History text file (. They are intended to be used as a convenience function.csv) Refer to Table 17 – Zone Attributes in this Section for an explanation of Day/Night Sensitivity settings.PFC-6030 • 5403595 • Rev a-2 • 10/11 System e-mail communications and functions are intended for informational reporting purposes only. Figure 68. Example of Detector "Sensitivity" Status Comma Separated Values file (. This section addresses how to accomplish these tasks. Mapping all Devices to One Zone Zone 1 1 5 7 6 2 3 4 Symbol Legend: = SLC Input = SLC Output P-2 P-1 = Panel Hardware DWG#593-34 Multiple Zones The panel configuration software allows you to customize the operational mode behavior of devices by grouping them into a maximum of ninety-nine (99) different zones. and an input device is activated. Please refer to the figure below for an example of a one-to-one device relationship: Figure 69. The panel configuration software allows you to efficiently group points to follow a sequence of events producing the same combination of outputs into different zones. Flexibility in configuring points into multiple zones promoting sophisticated mapping relationships. Whereas. one-to-one relationship where all devices are automatically grouped into one zone. modules and sensors and their behavior between each other. you can create unique relationships between devices for specific outputs or events. the “zone” is the framework in which you group the devices. Simple sorting and grouping by select fields enhances viewing and analysis of data. When all devices are in the same zone. These terms and other related mapping concepts are provided in this section. The panel configuration software features include: yy yy yy yy Easy to use Windows-based editing techniques.PFC-6030 • 5403595 • Rev a-2 • 10/11 System Programming System programming involves defining the function of devices and their relationships to each other. may be configured to behave in a specific manner. The two (2) on-board circuits (NAC 1 and NAC 2). This flexibility enables you to configure system points to maximize protection throughout your site. You can define behavior characteristics of individual or groups of devices. referred to as mapping. Options to view points by type. 5-59 . map devices into zones. Mapping Zones Overview Mapping is creating relationships between devices. including drag and drop between windows. all output devices will activate. Single Zones The LEARN feature creates or maps a basic. By organizing devices into different zones. address and function or description. and further customize your system using the panel configuration software from a computer. the output will be activated. all outputs activate. Used for all “Aux” inputs. Cross Zoning Example: Smoke detector in Zone 1 (R&D Lab). For procedures on how to select Zone styles.e.. Point Latching Non-Latching Any specific device. and one (1) strobe-NAC]. If all input / output devices are grouped into one (1) zone. yy The redundancy in this example provides verification of an alarm condition by requiring that both sensors in two (2) different zones are activated before an output occurs. their location may be scattered throughout the site. Example: Zone 2 comprised devices in Zone 1 as described above. The purpose of creating cross zones is to ensure that two (2) or more separate zones are activated before an output zone is triggered. yy Zones may represent a group of devices located in a specific physical area at the site. • Sets system into an Alarm condition when any input is activated. triggers an air handler circuit. 2. one (1) sounder base. Comprised of input / output devices that will activate when running a Fire Drill. A device or point may be mapped into more than one (1) zone. Zone Types / Styles You may define or configure each zone to serve a specific purpose or to create specific output results. when any input is activated. module or appliance connected to panel. Zone yy Zones may represent a set of devices configured for a specific function. i. [i. modules and sensors and defining their behavior. Notes: 1. This group is a “logical” grouping or zone. smoke detector resets once condition clears. The following zone styles are available: Table 16: Zone Styles Zone Alarm Supervisory Positive Alarm Sequence Auxiliary Fire Drill Description • Default zone type. plus a 2nd pull station located at end of a hallway and two (2) additional Sounder bases.PFC-6030 • 5403595 • Rev a-2 • 10/11 Mapping Terminology The table below provides mapping terms that may be helpful to you in understanding the mapping concept: Table 15: Mapping Terminology Term Mapping Definition Creating relationships between devices. Implements Positive Alarm Sequence. as soon as a pair of input devices detects an “alarm” condition. Example: Zone 1 comprised of all devices located in the main lobby of a hotel. and a heat detector in Zone 2 (Main entrance) are activated. yy There are no limits to the number of cross zones that can be mapped to the same output.e. Device will not automatically reset. Used for all Supervisory inputs. pull station #1. 5-60 . refer to the “Configuring Zones” section of this manual. Device will automatically reset when condition is no longer present.. device must be RESET at the keypad to remove condition. A group of devices. Used for outputs that will be activated upon any trouble. Example of Zone Attributes (Fields 1-10) Figure 71. Defines the number of inputs that must be in alarm before outputs are activated. The figures shown below are examples of the default attributes of an Alarm zone. among other attributes. silenceable vs. which displays on the LCD when an “off normal” condition occurs. Default is one (1). All zones default to an “Alarm” style or type when first created. Additionally. Figure 70. non-silenceable. 5-61 . Latching zone requires operator to press Reset. Example of Zone Attributes (Fields 11-14) Refer to the table below for a brief explanation of zone attributes: Table 17: Zone Attributes Attribute Zone Name Default = Zone “x” (where “x” is a sequential number) Alarm Count Default = 1 Silenceable / Non-Silenceable Default = Silenceable Description • • • • • Zone name may be up to sixteen (16) alphanumeric characters. Note: Double-click in field to modify alarm count. Non-latching zone will automatically turn off outputs when condition clears. The zone may be configured as latching or non-latching. Used for outputs that will be activated upon any supervisory. Zone name displays on LCD panel when an off normal condition occurs. • • • Available for one (1) count zones only. the zone’s name may be modified to a more descriptive name. Note: Double-click in field to modify zone name. Latching / Non-Latching Default = Latching Note: Click in selection box to remove latching setting. Zone Attributes Zone attributes are the settings that control the overall behavior of devices within the zone. Note: Click in selection box to remove “silenceable” setting. If zone defined as “silenceable” allows an operator to silence outputs by pressing the SILENCE button. up to 10 inputs may be selected.PFC-6030 • 5403595 • Rev a-2 • 10/11 Table 16: Zone Styles Zone System Alarm System Supervisory System Trouble Description Used for outputs that will be activated upon any alarm. Note: Double-click in field to modify setting. • Day sensitivity is functional during the time a building is normally occupied. i. Defines the amount of time before deactivating an output when the panel is reset. Sets alarm threshold for Fixed/ROR Heat Sensor (RHA). 5-62 .PFC-6030 • 5403595 • Rev a-2 • 10/11 Table 17: Zone Attributes Attribute Local / Non-Local Default = Non-Local Description • Used only for “Report by Zone” option.1% – 3.5% Default = 3. Holidays.5 sec on.5 sec off March Code 60 signals per minute Double Time 120 signals per minute Day Sensitivity Range: 1.. 1.5 sec off. Note: Click in selection box to select local option. • Allows a zone to be specified as a non-reporting zone.5% default represents the percentage of obscuration per foot for all smoke sensing detectors. Click on drop-down arrow to display and select an option: Constant 24VDC ANSI . Note: Double-click in field to modify setting. 5 sec on. Note: Double-click in field to modify setting. . . Defines the amount of time you may not silence an output when in alarm.e. Note: Double-click in field to modify sensitivity setting. Sets alarm threshold for Fix Temperature Heat Detectors (FHA). Night Sensitivity Range: 1.5% Heat Sensitivity Range: 135̊F – 185̊F Default = 135̊F Fixed/ROR Heat Sensitivity and 15̊ increase in 1 minute Range: 135̊F – 174̊F Default = 135̊F Auto-Silence Timer Range = 0 – 360 minutes Default = 0 minutes Auto-Unsilence Timer Range = 0 – 60 minutes Default = 0 minutes Silence-Inhibit Timer Range = 0 – 60 minutes Default = 0 minutes Restore Delay Range = 0 – 300 seconds Default = 0 minutes Defines the amount of time before silenceable NACs are automatically shut down. outputs only reactivate if panel is still in alarm. • Output Pattern Default = Constant • Defines the output pattern of general-purpose NAC circuits in the zone that occurs during alarm conditions.1% – 3. Note: Double-click in field to modify sensitivity setting.5 sec on. Note: Double-click in field to modify sensitivity setting.5% The 3. • Night sensitivity is functional during the times the building is unoccupied.5% Default = 2. Note: Double-click in field to modify setting. weekends.5 sec off.5% default represents the percentage of obscuration per foot for all smoke sensing detectors. Defines the amount of time before any silenced NACs are reactivated. • The term “obscuration” refers to the amount of reduction in air transparency caused by smoke. Note: Double-click in field to modify sensitivity setting. • The term “obscuration” refers to the amount of reduction in air transparency caused by smoke. . The 2. Zones Window 6. enter the zone number to begin numbering zones. Go to the “Zone Configuration” window. to view all available zones. 2. 5. Click OK or Cancel to exit dialog box. In “Number of Zones” field. The shortcut menu displays. Click on “Add Zones”. Examples of Adding Multiple Zones Dialog Box 3. The Zones window lists all new zones. Figure 74. if different from default. In the Zones window. This section explains this process and includes examples for your convenience. Example of Configuring Two (2) Zones 5-63 . enter the number of zones to create. In “Starting Zone Number” field. you may create one or more at a time. The Add Multiple Zones dialog box displays. right click on any zone name. Figure 73.PFC-6030 • 5403595 • Rev a-2 • 10/11 Creating Zones When creating zones. Note: You may enter up to ninety-nine (99) zones. Figure 72. 4. To create a zone: 1. . Zone name displays on LCD panel when off normal condition occurs. and other characteristics (i. Double-click in the Zone’s “Name” field to modify default name. � � Enter up to 16 alphanumeric characters.e. Refer to the Zone Attributes Table for field descriptions.).PFC-6030 • 5403595 • Rev a-2 • 10/11 Configuring Zones The next step is to customize a zone’s attributes. . etc. constant. 4. which includes changing the name. Click in “Style” field. To configure a zone: 1. Examples: “Main Lobby” or “Server Room”. Choose the applicable zone style (refer to the Zone Styles Table in this section for descriptions of zone styles). silenceable. Continue editing zone’s fields. double time output pattern. 5-64 . Click the drop-down arrow to display zone styles. auto-silence timer. 2. 3. latching or non-latching. selecting type of zone. or by groups of devices. 5-65 . Points may be configured from either the Zones or Points functions. however. General purpose NAC. Constant DC power. points are configured in the Points function. Drives Gentex synchronized horns / strobes. Constant DC power. Drives System Sensor synchronized horns / strobes. specific behavior characteristics. Constant DC power. Points can be configured individually. Refer to the table below for descriptions of the configuration functions. Drives Wheelock synchronized horns / strobes. obeys zone “output pattern” programming. disconnects on AC Loss or when an alarm occurs.PFC-6030 • 5403595 • Rev a-2 • 10/11 Configuring Points This section addresses how to define or configure points through the Points function. The user determines the Point's role. Below is an example of the Points window showing configured points. Figure 75. Notes: 1. Constant DC power. Each device may have a unique function in relation to the zone as well as the entire system. Example of Points Window NAC Functions The two (2) on-board circuits (NAC 1 and NAC 2) are automatically configured as “General Purpose”. The list of available functions is associated to the device or module type selected. Always on ANSI pattern used for ASB pattern synchronization. and customizes its name. Drives Potter synchronized horns / strobes. disconnects when an alarm occurs. but may be reconfigured and renamed. Table 18: NAC Circuit Configuration Functions Function Unused General Purpose Potter Sync Gentex Sync System Sensor Sync Wheelock Sync Aux Constant Aux Resettable Aux Door Holder Aux Door Holder Low AC Drop Aux ANSI Description Circuit is unused. for purposes of this manual. disconnects power during system reset. 2. if desired. PFC-6030 • 5403595 • Rev a-2 • 10/11 SLC Functions The SLC configuration options are described in the table below: Table 19: SLC Configuration Functions Function Unused Addr Detector Photo Addr Detector Photo Heat Addr Detector Heat Fixed Addr Detector Heat Combo Addr Relay General Purpose Addr NAC General Purpose Addr Zone Module Addr Sounder Base Addr Relay Base Contact Input Pull Station Contact Input Water Flow Contact Input Supervisory Contact Input Tamper Contact Input Fire Drill Contact Input Trouble Monitor Contact Input Aux Contact Input Reset Contact Input Silence Dry contact input options used with MCM, SCM or DCM modules. Description SLC point is unused. Photoelectric Sensor (PSA) Combination Photo-Heat Sensor (PSHA) Fixed Temperature Heat Detector (FHA) Combination Fixed Temperature and Rate-of-Rise Heat Detector (RHA) Addressable Relay Module (TRM) Monitored Output Module (MOM) Two-Wire Conventional Detector Module (CIZM) Addressable Sounder Base (ASB) Addressable Relay Base (ARB) 5-66 PFC-6030 • 5403595 • Rev a-2 • 10/11 To configure points: 1. Click on the Points function. The Points Configuration window displays. Figure 76. Configuration Window Examples Note: Click the columns to sort devices. 2. Devices are listed by “Built-in SLC” device address 1 to 30, followed by the two (2) power supplies (on board circuits). Note: Click on the “Device” field to sort the list by PWR Supply followed by SLCs. To configure a single point: 1. Double-click in “Name” field to enter a descriptive name. The current name is highlighted as shown: 2. Enter a new name (up to 16 alphanumeric characters). 3. Click on drop-down arrow in the “Function” field. Select a function type from the list. Figure 77. Example of Configuring a “Single” Point 4. Continue configuring other points, as needed. 5-67 PFC-6030 • 5403595 • Rev a-2 • 10/11 To configure a range of points: 1. Click the first point to configure from the “Function” field. 2. Press and hold the SHIFT key, then click in “Function” field of last point. Figure 78. Example of Configuring a “Range” of Points 3. Right-click from “Function” field to display configuration options. Note: If you right-click outside of “Function” field, the range is deselected, and only one (1) device will be configured. 4. Click on device type from shortcut menu. 5. Continue configuring other points, as needed. To configure a group of selective points: 1. Click the first point in “Function” field to configure. 2. Press and hold the CTRL key, then click selective points (from “Function” field). Figure 79. Example of Configuring “Multiple” Selective Points 3. Right-click from “Function” field to display configuration options. Note: If you select points or right-click outside of “Function” field, the points are deselected, and only one (1) device will be configured. 5-68 In the example shown here. Points can be moved and deleted from zones through the Zones panel using the “drag and drop” technique. Click on device type from shortcut menu. Open the Zones’ configuration window and adjust Points window to display functions. "Addr Detector Photo Heat" has been selected as the device type. Figure 82. Figure 80. Example of Configuring “Selective” Points Adding Points to Zones This section provides procedures and examples of adding points to one or more zones. To move one or more points into one zone: 1. Example of Resizing Points Window 2. Example of Selecting Multiple Points 5-69 . Click on one or more points to select. Figure 81.PFC-6030 • 5403595 • Rev a-2 • 10/11 4. The examples illustrate how to use shortcuts to expedite configuring zones and also to reinforce the interaction between the Zones and Points windows. use the SHIFT or CTRL keys to select a range or group of points. PFC-6030 • 5403595 • Rev a-2 • 10/11 3. Drag and drop selected points into Device window. 2. Example of Displaying Point’s Zone Assignment 5-70 . Figure 84. Figure 85. Example of Moving Selected Points into Zones 2 & 3 3. as shown below. Example of Moving Selected Points into Zone 1 To move one or more points into multiple zones: 1. Select the Zones in the Zones window and select points. Click “–” to collapse point assignments. Selected points display in “Device” window. Click “+” in Points window to display point assignment by Zone(s). Figure 83. Drag and drop selected points from Points window to “Device” window. Figure 87. To group by area (field): 1. Figure 88. as needed. as shown. Drag field out of “group by area” region to redisplay items in original order.PFC-6030 • 5403595 • Rev a-2 • 10/11 Group by Area The user can group information by different fields in many of the program windows. if available. Example of Points Grouped by Function 4. Note: Click on “group bar” at any time to collapse region. Group by Area Field 3. zones or remote annunciators. You may easily view or group by any field available in a window. Click “+” next to the function to view a complete list of points. Example of Group Bar in Points Window 2. Examples are included for illustration purposes only. Example of Points Configured as Addr Detector Photo 5. Click on “group bar” located at top of window. Figure 86. This option is helpful to configure or view a large amount of information. Figure 89. The information displays grouped by selected field. The “group by area” region displays. 5-71 . such as all devices. Click “-” to collapse list of points. Drag and drop one field into the “group by area” region. Create two or more (“Alarm” or “Supervisory” type) zone(s) and name appropriately.PFC-6030 • 5403595 • Rev a-2 • 10/11 Cross Zone Configurations The purpose of creating cross zones is to ensure that two (2) or more separate zones are activated before an output zone is triggered. Move devices into zones. To create a cross zone: 1. the cross zone relationship will not be in effect. 6. 3. All available zones display. 2. 7. Click to select input zone. Click on drop down arrow in “Output Zone” field. when all the zones that have been crossed are active. In this case. the specified outputs will be activated. Cross Zones Window Showing Enabled Note: If the “Enabled” option is not selected. Click on the drop down arrow in the “Input Zone 1” field. Configure and name devices. 5. Select output zone. Click in the “Enabled” box. Although crossing two (2) zones is the most common configuration. Repeat steps for the next field. up to eight (8) zones may be combined. 4. Open the Cross Zones window. “Input Zone 2” field. 5-72 . Figure 90. 8. trouble. DACT (UD-1000) Each system may have one DACT module or Digital Alarm Communicator Transmitter. such as number of rings. the PFC-6030 will operate as a local panel. 3. You may set up telephone parameters. and two (2) phone lines are used. An example of the Add – Dialer window is shown. Programming options allow you to select separate accounts for test events and alarm. RA-6075 and CA-6030 Class A expansion card. the test time may be programmed through the General Options program window (“Time to Send Autotest” field). DACT will alternate between lines on each daily call. Example of Dialer Reporting Options 5-73 . Troubles. The DACT provides notification to a remote monitoring company when alarms. Reporting Accounts The “Reporting Accounts” section is used to program DACT operations and to customize the format of the reporting accounts. Notes: 1. If a DACT is not installed. You may choose different settings for Alarms. Up to five (5) primary and secondary reporting accounts may be configured. 2. when and where to send reports by specifying phone numbers and other report output options. If the system has been programmed to use a dialer. and supervisory conditions. and Supervisory conditions. Figure 92. Figure 91. troubles and supervisory conditions occur. Example of DACT Add-Dialer Window These fields are important! Be sure to modify # of rings and line prefix fields according to your site's telephone setup! Refer to procedures on next page.PFC-6030 • 5403595 • Rev a-2 • 10/11 Programming Optional Modules This section addresses how to program optional P-Link appliances – the DACT (UD-1000). A daily test is automatically sent to a remote monitoring point. Figure 94.. Example of Add Dialer Window 3. Example of Phone Lines Options Each "." (commas) instruct the dialer to pause 2 seconds before dialing the reporting account numbers. In the “Phone Line 1 and Phone Line 2” fields. the phone line requires that "9" is dialed to get an outside line. if any is required for your phone lines. 5-74 . The “Add Dialer” window displays." (comma) creates a 1-second pause before the dialer attempts to dial a reporting account number. Note: If you do not change the default from "0". Click the Add Device button. The two ".PFC-6030 • 5403595 • Rev a-2 • 10/11 To add and configure a DACT module: 1. yy Enter the appropriate line prefix. Select the Dialer function from system panel. the DACT will never pick up a call! Example: In the example shown above. yy Enter the number of rings you want the DACT to pickup when receiving a call. 2. make any necessary changes. Figure 93. Figure 95. The “Add Device” window displays. Troubles. an error dialog box displays. 2. 4. Click the Add Device button. as shown below: Figure 97. To add and configure a Class A module: 1.PFC-6030 • 5403595 • Rev a-2 • 10/11 4. Unable to Add Dialog Box 3. make the necessary selections for the primary and secondary reporting accounts: yy Enter the Accounts IDs and Phone Numbers yy Select the Report types: Alarms. Zone or Point CA-6075 Class A Converter Module The PFC-6030 supports one (1) Class A Expander card. Double click in the “SLC Class” field to select class type (A or B). Double click in the “P-Link Class” field to select class type (A or B). Supervisory yy Choose the "Primary Format" option: CID / SIA Note: Both SIA-DCS and Ademco Contact ID protocols are supported. Example of Report Accounts Setup yy Select the Primary Report By option: Panel. In the “Reporting Accounts” section. CA-6030 Class A – Add Device Window Note: If you attempt to add more than one (1) Class A card. Select the Class A Card function from system panel. 5-75 . Figure 96. Double click in “Address” field to adjust address. 4. Each LCD annunciator may be programmed with a unique name to easily distinguish where an “off normal” condition has occurred. Select the Annunciators function from system panel. 2.PFC-6030 • 5403595 • Rev a-2 • 10/11 Remote Annunciators (RA-6075) The RA-6075 supports up to thirty-one (31) remote annunciators. To add and configure a remote annunciator: 1. Double click in the “Name” field to customize name. Click the Add Device button to display the "Add Device” window. if needed. 3. 5-76 . PFC-6030 • 5403595 • Rev a-2 • 10/11 Appendix A: Basic Operating Instructions These instructions must be framed and displayed next to the PFC-6030 panel in accordance with NFPA 72 fire code for Local Protected Fire Alarm Systems. Function View Point’s Status Check Detector Sensitivity A-1 . detector address and type displays. press ENTER. enter panel’s code. • Press Up to display Day/Night Sensitivity settings. • Enter Addr / Ckt No. Troubles Reset Alarms View Alarms. • Press 1 – SLC Tools. and press ENTER. • Scroll Up/Down to choose Internal SLC / PWR. Press the DRILL pushbutton. • Press 5 – System Tools. • Press Up / Down to scroll through point’s day / night sensitivity settings. • Press 2 – Point Control. and press ENTER. Press the RESET pushbutton. press the ESC button to exit Drill mode. Press arrows to view alarms / troubles. • Press ENTER to display the Main Menu. • Enter Addr #. • Press ENTER to display current usage. Table 20: Button Functions Button ACK Arrows Drill Esc Reset Silence Table 21: Operating Instructions Operation Silence Alarms. • Press 1 – SLC Pinpoint. • Press Up/Down to view previous / next points. • Press ENTER to display the Main Menu. Test the system in accordance to NFPA 72. Troubles Conduct a Fire Drill Task Press the SILENCE pushbutton. Troubles Acknowledge Alarms. enter panel’s code. • Press 5 – System Tools. Press the ACK pushbutton. use right arrow to move through date field and to display time field.PFC-6030 • 5403595 • Rev a-2 • 10/11 Table 21: Operating Instructions Operation Task • Press ENTER – Main Menu. Set Date / Time Enable / Disable Point • Press ENTER – Main Menu. and press ENTER. • Press ENTER to change status. • Point’s current status displays “Normal” if enabled. View Event History Service Call: A-2 . • Press 1 – View History. • Press 2 – Enable/Disable. • Press 3 – Set Date / Time. or “Disabled”. • Scroll Up / Down to select Internal SLC / PWR. • Enter Addr / Ckt No. • Press Up / Down to scroll. and press ENTER. • Press ENTER – Main Menu. enter panel’s code. • Use keypad to enter correct date. • Press Left / Right to view next / previous events. • Press ESC to exit. • Press ENTER to save changes. press ENTER to save or ESC to exit without saving. and specifying the modem com port. Example of Com Port Modem Setup 4. Figure 99. B-1 . a modem may also require an initialization string. Click OK to save changes. Refer to your manufacturer’s instructions for this information. To setup a modem: 1. If required. Select Options – Communication. Click in “Modem Com Port” field to select the applicable com port.PFC-6030 • 5403595 • Rev a-2 • 10/11 Appendix B: Modem Connectivity Setup If your computer uses a modem for connectivity to the panel. enter the initialization string. This involves choosing “Modem” as the transfer medium. In rare instances. The "Communication – Options" dialog box displays. 3. Example of Modem Communication Setup 2. Figure 98. Click in “Default Transfer Medium” field and select “modem”. choose the Options – Communications menu option. Testing should be conducted by Potter factory trained fire alarm technician(s) in the presence of a representative of the Authority Having Jurisdiction (AHJ) and the building owners representative.0 A and reaches the float voltage of 27.3 VDC within 48 hours. all initiating devices. Refer to NFPA 72 (National Fire Alarm Code). Service and test the control panel according to the schedules and procedures outlined in the following documents: • • NFPA 72. A typical discharged battery will recharge at 1. Testing and Maintenance or CAN/ULC-S524M (Standard for the Installation of Fire Alarm Systems). Inspection. The test of ground fault must be measured in below 10k ohms impedance. The AC fuse is rated at 8A 250VAC TimeLag and screened onto the main board as F1.. all notification appliances and any other associated equipment is essential to ensure the system will operate as designed in emergency situations.e. Service manuals and instructions for any and all peripheral devices installed in the system. Verify that all LED’s and LCD segments operate. The battery is to remain in the cabinet with nothing on or around the batteries. Operational Checks During interim periods between formal testing and at regular intervals the control system should be subjected to the following operational performance checks. Using the system menus. The Authority Having Jurisdiction (AHJ) should be consulted for requirements on frequency of system testing. perform a Lamp Test function. and (3) When necessary. central alarm receiving station and /or building personnel when finished with testing the system. Check that all amber LED’s are off. C-1 . Notify Fire Department. (2) Notify facility personnel of the test so that alarm-indicating devices are disregarded during the test period. It is very important that any and all trouble conditions (or faults) be corrected immediately. • • • AC Fuse The control panel has one fuse on the board for the AC power over current protection. Before proceeding: (1) Notify the fire department and the central alarm receiving station if transmitting alarm status conditions.PFC-6030 • 5403595 • Rev a-2 • 10/11 Appendix C: System Maintenance and Testing Acceptance Test The control panel is required to be installed in accordance with local and state building codes and NFPA 72 (National Fire Alarm Code) or in accordance of CAN/ULC-S524M (Standard for the Installation of Fire Alarm Systems). These sealed lead acid batteries do not require any additional water or electrolyte. the control panel and related system is required to be inspected and tested in accordance with NFPA 72 or CAN/ULC-S524M to verify compliance with the applicable standards. Activate an input device (i. Battery Maintenance The system has been designed to use maintenance-free sealed lead acid batteries. heat or smoke detector). The system will keep all batteries fully charged by the system's power supply modules float charger. At the conclusion of each original installation or modification of this system. Periodic Testing and Service Periodic testing and maintenance of the control panel. manual station. Inspection Testing and Maintenance or CAN/ULC-S536 (Standard for the Inspection and Testing of Fire Alarm Systems). and check that all notification appliances function. • • • • Check that the green AC power LED is lit. bypass activation of alarm notification appliances and speakers (if installed) to prevent sounding of evacuation signals. and always replace batteries in pairs. If Sulfuric Acid makes contact with eyes. Batteries should be dated at the installation. jewelry and coins. If a battery is shorted. the battery and any connected equipment may be damaged. Minimal replacement battery capacity displays on the control panel marking label. Water and household baking soda provides a good neutralizing solution for Sulfuric Acid. Ensure proper handling of the battery to prevent short-circuits. Proper Handling / First Aid Procedures • • • • • In the event a battery leaks and contact is made with the Sulfuric Acid. Immediately replace a damaged or leaking battery. The battery is to be tested at least annually and if the battery is showing signs of failure. The batteries are required to be UL recognized batteries with a date of manufacture permanently marked on the battery.PFC-6030 • 5403595 • Rev a-2 • 10/11 Replacement and Testing Recommendations The batteries are to be replaced at least once every four years or more frequently if specified by local AHJ and manufacturer recommendations. Additionally. tools. C-2 . it should be replaced. seek immediate medical attention. Take care to avoid accidental shorting of the leads from uninsulated work surfaces. immediately flush eyes and/or skin with water for at least 15 minutes. a short may injure personnel. Therefore. Silent Knight Model 9500/9800 (Ademco MX8000) Sur-Gard System III RA-6075 – LCD Remote Annunciator Two-Wire (2-Wire) Smoke Detectors SLC Devices DACT/DACR (UD-1000) Receivers RS-485 Devices Class A Expander CA-6075 Class A Expander D-1 . accounts could be the same reporting type. optional modules. please refer to CIZM Installation Sheet. None listed with the control panel. two-wire (2-wire) smoke detectors. all devices listed the Conventional Input Zone Module (CIZM). Similarly. Each account may be configured for Contact ID or SIA-DCS independent of the other account’s setting. and other device compatibilities.PFC-6030 • 5403595 • Rev a-2 • 10/11 Appendix D: Compatible Devices Table This section provides a listing of all NAC appliances. some account(s) could be Contact ID and others could be SIA-DCS or vice versa. PSA – Photoelectric Smoke Detector PSHA – Photoelectric/Heat Smoke Detector FHA – Fixed Temperature Heat Detector RHA – Rate of Rise/fixed Temperature Heat Detector AIB – Addressable Isolator Base ARB – Addressable Relay Base ASB – Addressable Sounder Base MCM – Miniature Contact Module SCM-4 – Single Contact Module DCM-4 – Dual Contact Module TRM-4 – Twin Relay Module MOM-4 – Monitored Output Module CIZM-4 – Conventional Input Zone Module SCI – Short Circuit Isolator UD-1000 DACT – The DACT transmits in Ademco Contact ID and Security Industries Association’s Digital Communication Standards (SIA-DCS). releasing and SLC circuit devices. Table 22: Device / Modules Compatibilities Module/Devince NAC Appliances Compatibilities Refer to Potter document “5403592-B NAC Compatibility Document”. FACP found multiple devices with the same address. their descriptions and recommended actions for each condition. Device is not programmed for the correct function. The panel is not able to communicate with a device. FACP found a non-programmed device. Table 23: Troubleshooting Error Message Keypad “##”: Missing SLC “##”: TYPE ERR SLC “##”: XTRA DEV SLC “##”: DUP ADDR SLC LOOP SHORTED NAC “##”: OPEN NAC “##”: Shorted Error Description/Action The panel is not able to communicate with the annunciator. Action: Check for 24 VDC to the device. Action: Locate short and repair accordingly.PFC-6030 • 5403595 • Rev a-2 • 10/11 Appendix E: Troubleshooting Tips This section provides basic error messages. There is a short on the SLC loop wiring. There is an open on the wiring. Action: Check wiring and programming. Action: Check device is currently operating and/or connect device to SLC loop. Action: Locate open and repair accordingly. Action: Run LEARN or program specific device. Action: Manually reassign address of one of the devices. There is a short on the Notification Circuit’s wiring. Back up batteries are missing or need to be replaced. • SLC “##”: OPEN/PWR • Monitored Output Module is missing 24 VDC connection. Action: Locate short and repair accordingly. Action: Program device for correct function. SLC 1: Missing E-1 . Action: Connect or replace batteries as needed. enter the menu selection number on the keypad to select a function. Gateway 7=Alt. F-1 .PFC-6030 • 5403595 • Rev a-2 • 10/11 Appendix F: Control Panel Menu MAIN MENU 1=View History 2=Enable/Disable 3=Set Date/Time 4=Walk Test Select Device Internal SLC Internal PWR MAIN MENU 5=System Tools 6=Programming 7=Data Transfer Esc=Exit 1=SLC Tools 2=Point Control 3=Ethernet Status 4=DACT Test 5=DACT Reset 6=Erase History 7=Lamp Test 8=App Revisions 1=LEARN Mode 2=Panel Default 3=IP Settings 4=Dflt ID/Pswd 5=Prog ID/Pswd Esc=Exit Select Data 1=Remote Access 2=E-mail Det Stat 3=E-mail History 4=E-mail Config 5=E-mail Test 6=Server Status Esc=Exit 1=SLC Pinpoint 2=SLC Stats 3=SLC Addr Prog 1=Username 2=Password Esc=Exit 1=Single Device 2=Mltp Device Ethernet Options 1=DHCP Settings 2=Default IP 3=Default Gateway 4=Default Subnet 5=Alternate IP 6=Alt. Subnet Esc=Exit TIP: To save time. For example. press “3” to select “Set Date/Time” from the Main Menu. . Additionally. and the buzzer will be activated. the amber TROUBLE LED will illuminate and the local buzzer will sound until the fault is removed or the ACK button is pressed acknowledging the trouble condition. The LCD display will indicate the number of supervisory events that are active. the amber EARTH FAULT LED will illuminate and the LCD display will provide further information of where the fault is located. the notification circuits (strobes and horns) can be shut off by pushing the SILENCE button. once the device is restored to the normal condition. 5403596 for the proper rating. If the Supervisory condition is non-latching. During Positive Alarm Sequence operation the “ACK” key must be pressed within 15 seconds of the alarm initiation to activate the investigation timer. or until the Silence key is pressed. 6030 Normal Standby Acknowledging The green AC POWER LED will be illuminated and the user defined message on the LCD will be displayed. Releasing and reactivating the Abort will set the timer to 10 seconds. Additionally. the amber SUPERVISORY LED will illuminate and the buzzer will sound. the system may be reset to the Normal Standby by pressing the RESET button. The amber Pre-Release LED will illuminate when the system is in a count down timer for an agent release. contact: Name: Company: Frame and display instructions adjacent to the fire alarm panel. Testing and Maintenance Chapter(s) and any local requirements. Contact the agency below for service or operational questions. the supervisory event will clear. Batteries should be checked with a tester acceptable to the AHJ such as a Stone Technologies model STC612A or equivalent. 5403596. When a supervisory condition is detected. the device that was activated must be restored and the RESET pressed. pushing the Abort will allow the timer to countdown until 10 seconds and then halt. Test the circuits as outlined in the Installation Manual. 6075. release events will be displayed on the LCD. Off normal events are acknowledged by pressing the ACK key while reviewing events. the buzzer will resound. For ULI installations. Test this system monthly or more frequently as required by the AHJ. In case of a fuse replacement. The local buzzer will sound until all supervisory events have been acknowledged. If the buzzer is acknowledged and the fault is not removed within 24 hours. activate the releasing disconnect switch to prevent accidental discharge of a suppression system. The buzzer will remain active until all alarms have been acknowledged. refer to the Installation Manual. The red ALARM LED will be illuminated anytime an alarm is occurring in the system. Test in accordance with NFPA 72 Inspection. When a fault condition occurs. 5409071–Rev A Address: Telephone: Alarm Condition Silencing Alarm Resetting Alarm Supervisory Condition Restoring Supervisory Condition Trouble Condition Silencing Trouble(s) Ground Fault Pre-Release (PFC-6075R Only) Release (PFC-6075R Only) Agent Release Abort (PFC-6075R Only) Testing and Maintenance . The red Release LED will illuminate when a release condition is active. Before conducting any testing contact the building personnel and the monitoring facility as applicable. the release may be aborted by pressing the abort switch. For service. the buzzer will deactivate and the associated LED will stop flashing and remain on continuously. After all events have been acknowledged. After the condition that caused the alarm has been identified and corrected. If the supervisory condition is latching. the local buzzer will sound until either all troubles have been acknowledged or the SILENCE button is pressed When a conductor contacts and earth ground. When the system is in Alarm. pre-release events and countdown timers are displayed on the LCD. If the system is being used as an agent releasing panel and a pre-discharge timer is programmed.Operating Instructions for PFC-6075R. The LCD will display the number of inputs in alarm. If the AC power is removed for more than 5 seconds. When a trouble is occurring. the green AC power LED will extinguish. The batteries should be marked with the date of installation and replaced every four years or sooner if battery trouble occurs. When testing a system configured for releasing.
Copyright © 2024 DOKUMEN.SITE Inc.