Manual Rics Myd Cf-1 v3.1 L-ie-5171

March 28, 2018 | Author: Francisco Gomez | Category: Stereoscopy, Microsoft Windows, Microsoft, Technology, Computing


Comments



Description

*L-IE-5171* Retinal imaging control software MYD (CF-1) Version 3.1 New Features Guide Introduction Before using this software, read the Operation Manual for Retinal imaging control software MYD (CF-1) version 2.0 (hereinafter “Operation Manual”). Operating precautions are also included in the Operation Manual. This guide explains additional features that are not included in the Operation Manual. Please read this guide along with the Operation Manual. Keep these documents so that you can use them in the future. New Features New features in version 3.1 are listed below. • Deleting rows from the Patient History list (See page 3) • Displaying the memory space required and available when saving the study log data (See page 3) • Capturing stereo images (See page 3) • Displaying the image in full-screen (See page 5) • Changing the capture settings on the Study screen (See page 6) • Pairing images for the stereo image (See page 7) • Saving the displayed image in TIFF format (See page 9) • Setting the personal name separator conversion rules for DICOM (See page 9) • Overlaying the timer on the image (See page 10) • Setting the transfer syntax for DICOM (See page 10) • Anonymizing patient information for transfer (See page 11) • Entering login user name in five name elements (See page 12) EOS 40D.0. and EOS 50D .1. 7. for communication with digital camera USB1.0. Hardware or Software 2 Specifications CPU Core 2 Duo 2.5 SQL Server 2005 Express Edition SP3 Canon Easy-PhotoPrint EX Version 2.5 inch.0 or later. Applications Microsoft.NET Framework Version 3.4 GHz or higher RAM 2 GB or more Display Screen resolution: XGA (1024 x 768 pixels) or higher SXGA (1280 x 1024 pixels) or more recommended Screen colors: 24 bits or more Hard disk 3.Software Requirements Version 3. for communication with retinal camera: emulating RS-232C RS-232C (for magnetic card and barcode reader) Operating system Microsoft Windows XP Professional SP2/SP3* Microsoft Windows Vista Business SP1/SP2* * This software does not support x64 (64-bit versions). for printing images Compatible EOS EOS 30D.200 rpm or higher Mouse Microsoft Mouse or compatible mouse Interface USB2.1 runs in the following environment. The updated specifications are shown in bold. 3 “Magnetic card/barcode input” in the Operation Manual. the required and available memory are displayed on the Save screen.2 “Manual input” and 4.2. The row is deleted but the study information is retained. 1 Click [Capture for Stereo View]. Stereo Photography button Indicates the side that the image is taken 3 . Click the row you want to delete to select it. A light green bar appears above the stereo capture side. Displaying Required and Available Memory in Destination to Save Study Log Data When saving temporarily saved study log data. See also sections 4. See also the operation manual for the stereo unit to capture stereo images with the Stereo Unit. The Stereo View screen appears.2. and press the Delete key. Capturing Stereo Images Use the stereo unit (optional) to capture stereo images.Descriptions of New Functions Deleting Rows from Patient History List You can delete unnecessary rows from the Patient History list. To recapture an image. A light green bar appears above the right side of the screen.Capturing Stereo Images 2 The captured image for the left side appears on the left side of the Stereo View screen. 3 4 The right side of the stereo image appears on the right side of the screen. capture the right side of the stereo image. To recapture the left side. click a side and recapture the image. click the left side of the screen. . Next. Click [Full Screen] or double-click the thumbnail that you want to display in full screen. 5 .1 “Main screen” in the Operation Manual. To return to the previous screen. The stereo mark appears on the thumbnail of stereo images. Close the Stereo View screen to return to the main screen. Double-click Full Screen button Return button To change the displayed image. Stereo mark Displaying Image in Full-screen The main image display area on the main screen can be displayed in full screen. See also section 6. press the left or right arrow key.Displaying Image in Full-screen 4 Click the [OK] button. click [Return] or press the ESC key. the image format and size. you can change the capture settings. Full Screen button Double-click Return button To change the displayed image. for example. Changing Capture Settings During Examination You can open the Capture screen with a click of a button when you are about to capture an image. The items that can be set vary depending on the photography mode. 1 Click [Capture Settings] on the toolbar. click [Full Screen] or double click a thumbnail that you want to display in full screen.Changing Capture Settings During Examination In the RGB channels screen. press the left or right arrow key. Color mode screen shown for an example 6 . Capture Settings button 2 Change settings as you want. On the Capture screen. or move) Switch right and left images Pair as stereo image. zoom out. The stereo mark appears. The stereo mark (glasses) on the thumbnails indicates stereo images. Displaying Stereo Images You can display captured stereo images side by side.Viewing Stereo Images 3 Click [OK] to close the Capture screen. Unpair the images. Viewing Stereo Images You can display captured stereo images side by side in the Stereo View screen. 1 Click a thumbnail that has the stereo mark. 7 . zoom out. or to adjust the image. the Zoom In tool is selected for the mouse. Initially. Stereo mark 2 3 Click [Stereo View]. Zoom In tool Adjust images Apply the same effect to both images (zoom in. You can also pair two images captured separately as a stereo image. 4 Click [Close] to exit the Stereo View screen. To zoom in. or unpair two images. The Stereo Screen appears. The stereo mark disappears. click the image once. 1 2 3 4 Click the thumbnail of the first image you want to pair as a stereo image. Adjust images Apply the same effect to both images (zoom in. 8 .Viewing Stereo Images Pairing Images for Stereo Display You can record unpaired captured images as stereo images on the Stereo View screen. zoom out. or move) Switch right and left images Pair as stereo image. The stereo mark appears. Click [Pair]. Unpair the images. Click [Stereo View]. The images in the side-by-side alignment are recorded as a stereo image. The Stereo View screen appears in the side-by-side alignment that the thumbnails are displayed. Hold the Ctrl key and click the thumbnail of the second image. The stereo mark disappears. . 9 . Setting Personal Name Separator Conversion Rule in DICOM You can set the conversion rule for the separator between name elements in DICOM. The setting is applied to screen displays and DICOM text string output. See also section 6.Lossless or Tiff files . Select [File] > [Save As.LZW from the Save as type list box. select a conversion rule option. See also section 7.2 “System” in the Operation Manual. Select Tiff files . On the Other tab of the System screen..Saving Displayed Image in TIFF Format 5 Click [Close]. Stereo mark Saving Displayed Image in TIFF Format You can save the image displayed on the main screen in TIFF format.] from the menu.11 “Saving as JPEG Files” in the Operation Manual. The stereo mark is added to the thumbnails. Timer Setting Transfer Syntax for DICOM You can specify a transfer syntax to export images in DICOM when the No Compression option is selected for the Image Compression. Explicit VR Little Endian. Open the Create a New Storage screen (or the Change a Storage screen) and check the [Overlay Timer] checkbox. See also section 7.6. The size of the characters is optimized for the image size.Overlaying Timer on Image Overlaying Timer on Image You can transfer the timer overlaid on the fluorescein angiography image. See also section 7. and Explicit VR Big Endian. 10 .2 “Advanced export settings” in the Operation Manual.6 “Storage” in the Operation Manual. The timer is displayed in the lower right of the transferred image. You can select one from Implicit VR Little Endian. 6 Click [OK]. The Anonymization Settings screen appears. checkbox. Select the Anonymize Patient Info. When Replace is selected for Anonymization Type. The Anonymization Settings screen closes. See also section 7. Click the [Anonymize Settings] button. Select the items that you want to anonymize. Select the Anonymization Type from the list box (Blank or Replace).6 “Storage” in the Operation Manual.Anonymizing Patient Information Anonymizing Patient Information The Retinal imaging control software MYD can anonymize pieces of patient information that are appended to transferred images. 11 . 1 2 3 4 5 Open the Create a New Storage screen or Change a Storage screen. input a text string that replaces the original value. 001 © CANON INC. In the User Accounts screen.8.Entering Login User Name in Five Elements Entering Login User Name in Five Elements You can divide and enter the log-in user name into five elements.1 “Registering users” in the Operation Manual. click [Create a new account] or [Change an account] and enter the name. The user name is saved as the DICOM tag of the operator’s name. 2010 Printed in Japan . PUB. See also section 7.L-IE-5171 0310P0.
Copyright © 2024 DOKUMEN.SITE Inc.