SISTEMA FLATPACK 2> José Rodas Utani Jefe de Servicios & Soporte Técnico Perú, Ecuador y Bolivia Slide 2 of 23 29.04.2013 Generation 4 Slide 3 of 23 29.04.2013 04.1. Highest Power Density 33W/in3 FP2 3000 Generation 4 25W/in3 FP2 2000 FP2 1800 20W/in3 Generation 3 15W/in3 Flatpack 1800 Flatpack 1500 10W/in3 SMPS 1000 5W/in3 SMPS 60/20 Generation Saves the customer money by : - Slide 4 of 23 29.2013 1 More space for customer equipment and/or batteries Thus less cabinets and less footprint in the location . 5” Deep With four rectifiers installed 1U – 1.5” Wide – 167A Maximum Per Shelf brackets mount 19”. Highest Power Density – FP2 2KW SHELF Dimensions Slide 5 of 23 29.2013 Modular Configuration 48 VDC 17. 21” or 23” 125A Redundant 14.04.75” Height .1. 5A Redundant 17” Deep With four rectifiers installed 1U – 1.04. Highest Power Density – FP2 3KW SHELF Dimensions Slide 6 of 23 29.1.75” Height . 21” or 23” 187.2013 Modular Configuration 48 VDC 17.5” Wide – 250A Maximum Per Shelf brackets mount 19”. un peso más ligero.especialmente como repuestos Logística .2.5mm 327 mm 109 mm Más fácil para dirigir : - Slide 7 of 23 29.04.9 Kg 41.2013 Personal de mantenimiento . Pequeño y ligero < 1. significa menos costos de envío . 2013 Evitar las salidas de llamadas de prioridad (fuera de horas normales) Da una alta eficacia del rectificador .3.will work with only one (Back to front version in design stage) Ahorros por costos de mantenimiento y operación por : • - Slide 8 of 23 29. Operación de los ventiladores 2 Fans – Front to back airflow .04. 4. Ahorro de tiempo y dinero por : - Slide 9 of 23 29.04. Controles digitales 2 controlador digital : Dan mas supervisión y control.2013 Dando al operadores una información más en tiempo real del sistema El personal de mantenimiento sabe exactamente qué necesita hacer con las ayudas. . 5. Edge connectors Communications AC Input DC Output Edge-connector technology Ahorra tiempo (y dinero) : - Slide 10 of 23 29.04. Reduce fallas de interconexión.2013 Módulos intercambiables en caliente. . 6.04. Input voltage 2000W 1800W Nominal Input 850W 650W 0W 185 85V Red LED Slide 11 of 23 29. Amplio Rango de entrada CA Output Power vs.2013 Yellow LED 290 300 Green LED Red LED . 6.2013 FP2 48/3000 300 350 . Large AC input range Mains derating Output Power (%) 120 > Derating below 176Vac (185Vac on 2kW module) 100 80 60 > 1382W (46%) at 85Vac 40 20 0 0 50 100 150 200 250 Voltage (Vac) FP2 48/2000 Slide 12 of 23 29.04. 7. Temperatura De-rating Temperatura ambiente (max full carga de salida) 2000W 1800W 1400W Linear De-rating Zone o o +75 +45 Green LED Slide 13 of 23 29.04.2013 1200W Yellow LED 0W Red LED . 7.04.2013 FP248/3000 70 80 . Temperature De-rating Temperature derating Output Power (%) 120 > Derating above 45 oC 100 80 > 2100W (67%) at 75 oC 60 40 > Delivers 50A at 65 oC 20 > Operating down to -40 oC 0 0 10 20 30 40 50 60 Ambient temperature FP2 48/2000 Slide 14 of 23 29. 04.8.2013 · Short circuit proof (constant current) · Single or double fan blockage/failure . Excelente protección en AC/DC Mains fuse: 2x15 A (fast) in Live and Neutral Varistor across the lines for transient protection Hi -ohmic disconnect above 290V / 300V AC (with auto reconnect when in range) DC Output DC output : Blocking Diode Slide 15 of 23 29. 9.04.5 Eff.5 90 0 200 400 600 800 1000 Pout(W) Slide 16 of 23 29.5 91 90.2013 1200 1400 1600 1800 2000 .(%) 92 Max Efficiency Zone 91. Highly Efficient – 2 KW 2000W rectifier : Efficiency at 230Vac input 93 92. 2013 70 80 90 100 .9.04. Highly Efficient – 3 KW > Efficiency above 93% at 40-80% load. 92.4% at 100% load 94 93 > 10% loss reduction on system level Efficiency (%) > Low load efficiency also improved 92 91 90 89 88 87 3000W 2000W 86 0 10 20 30 40 50 60 Load (% ) Slide 17 of 23 29. 04.2013 . Highly Efficient – 2 KW HE Slide 18 of 23 29.9. 2013 .04.Technical Data – 24V 2000 W Slide 19 of 23 29. Technical Data – 48 V 1800 W Slide 20 of 23 29.2013 .04. 04.Technical Data – 48 V 2000 W Slide 21 of 23 29.2013 . 04.Technical Data – 48 V 3000 W Slide 22 of 23 29.2013 . Technical Data – 48 V 2000 W HE Slide 23 of 23 29.04.2013 . Procedimiento de instalación Handle in locked position Hole to release the handle’s spring mechanism Handle in unlocked position Slide 24 of 23 29.04.2013 . Panel Frontal Dual Fan Cooling GREEN Power LED Slide 25 of 23 29.2013 RED Alarm LED YELLOW Warning LED .04. 04.Panel Frontal Power (green) Slide 26 of 23 29.2013 ON Rectifier is powered Flashing Smartpack controller accessing information on the rectifier OFF Mains are unavailable . 2013 Rectifier is in Derating Mode (reduced output power) high internal temperature (+65 to 70 C) or low input voltage (lower than 176VAC) or single fan failure The remote Battery Current Limit is activated AC input voltage is out of range Rectifier in stand-alone mode (or loss of communication with the Smartpack controller Flashing Rectifier is in Over-voltage Protection Mode OFF No abnormal situation is present .04.Panel Frontal Warning (yellow) ON Slide 27 of 23 29. Panel Frontal Alarm (red) ON OFF Slide 28 of 23 29.5VDC) CAN bus failure No alarm situation is present .04.5 VDC) Internal rectifier failure (malfunction) Fan failure (double fan malfunction) Low output voltage (0 to 43.2013 Rectifier is in Shut-down Mode due to low mains (0 – 85VAC) or high internal temperature (+75 C or higher) or high output voltage (higher than 59. Unidad de Control > Scaleable y modular.2013 . control flexible para la gama entera de productos Eltek Slide 29 of 23 29.04. Unidad de Control Slide 30 of 23 29.2013 > Front panel backlit LCD (2x16) and key pad > USB for PC connection and easy FW uploading > CAN bus para comunicacion con modulos Eltek > 6 entradas digitales programables > 6 relay de salidas configurables > Latched contactor control > Monitoreo y test de baterias > Compensacion de carga por temperatura > 8 symmetry measurements > log de eventos(10000) con hora y fecha.04. > Windows-based PC communication software . 2013 .04.Pequeño pero de gran alcance < 300g 44mm 144 mm 109 mm Slide 31 of 23 29. 2013 Battery. Control System & Mains > Alarm LED (red) = Major Alarm active > Warning LED (yellow) = Minor Alarm active > Power LED (green) = Normal status active . Load.04. Rectifier.Smartpack Vista Frontal > ”Top-level alarms” scrolls on display when active • Slide 32 of 23 29. 110 (RoHS compliant) Slide 33 of 23 29.2013 • Max 8 Smartpack • Max 50 Rectifiers .04.Panel Trasero CAN Bus CAN bus ID based serial bus communications • Part No : 242100. Part No : 242100.04.Panel Trasero Monitoreo de Baterías Monitoreo de Baterías Con 4 : Standard Con 3 : Extended • Symmetry measurement • 8 strings mid point or 2 strings 12V block • Sensor de Temp.2013 .110 (RoHS compliant) Slide 34 of 23 29. batt fuse Con 4 : Not used Slide 35 of 23 29.04.2013 .Conectividad Batería > CON3 & CON4 – Conexiones de baterías Cable Sensor de Temperatura Pin Function 1 Symmetry I/P 1 2 Symmetry I/P 2 3 Symmetry I/P 3 4 Symmetry I/P 4 5 Symmetry I/P 5 6 Symmetry I/P 6 7 Symmetry I/P 7 8 Symmetry I/P 8 9-10 Con 3 : Temp sense 2 Con 4 : Temp sense 1 11 .14 Con 3 – 2nd batt current. 2013 .Conectividad .Batería > CON3 & CON4 – Conexión de batería Slide 36 of 23 29.04. Conectividad Symmetry > Symmetry measurement options Slide 37 of 23 29.04.2013 Panel Trasero Sistema interno Sistema Interno System measurements Unit Power 2xLVD control (Latched) Part No : 242100.110 (RoHS compliant) Slide 38 of 23 29.04.2013 Battery fuse fail Conectividad Sistema > CON5 – Conexión del sistema System Connection Card. Art 200625 Slide 39 of 23 29.04.2013 Pin Function 1 Positive Input 2 Negative Input 3 Batt Current +ve 4 Batt Current -ve 5 Batt Fuse +ve 6 Batt Fuse -ve 7 Load Fuse Fail 8 LVD1 Active 9 LVD1 Common 10 LVD2 Active 11 LVD2 Common Conectividad Sistema > Sistema de Configuración de la tarjeta JP1 -48v system = 1-2 +24v system = 2-3 JP2 -48v system = „Neg‟ +24v system = „Pos‟ Slide 40 of 23 29.04.2013 . 2013 Con 2 (extended):4 + 4 relay input / output .04.110 (RoHS compliant) Slide 41 of 23 29.Panel Trasero Alarmas I/O Alarma I/O Con 1 (standard):2 + 2 relay input / output Part No : 242100. 10 Alarm output 2 ( NO /C / NC) 1-2 Alarm input 3 ( + / -) 3-4 Alarm input 4 ( + / -) 5-6 Alarm input 5 ( + / -) 7-8 Alarm input 6 ( + / -) 9 .Conectividad Externa y Alarm I/O > CON1 & CON2 – I/O Conexiones Alarm Output & Input Card Art 105954 Slide 42 of 23 29.04.20 Alarm output 6 ( NO /C / NC) .11 Alarm output 3 ( NO /C / NC) 12 .14 Alarm output 4 ( NO /C / NC) 15 .2013 Pin Function 1-2 Alarm input 1 ( + / -) 3–4 Alarm input 2 ( + / -) 5-7 Alarm output 1 ( NO /C / NC) 8 .17 Alarm output 5 ( NO /C / NC) 18 . RS-232 Opciones RS-232 mounted Enables connection of Standalone Webpower or modem • Part No : 242100.111 (RoHS compliant) .04.2013 Part No : 242100.112 (RoHS compliant) Rear position : Replaces extended Battery symmetry card • Slide 43 of 23 29. Smartpack Smartpack Extended RS232 Slide 44 of 23 29.2013 .04. 2013 Ethernet interface of remote monitoring of Smartpack Is possible to “tunnel” Powersuite remotely also. .Panel Trasero Webpower incluido Embedded WebPower Part No : 242100.04.113 (RoHS compliant) Slide 45 of 23 29. 04.Smartpack Smartpack SNMP/Webpower Slide 46 of 23 29.2013 . Escalabilidad CAN/Power bus Smartpack Master Smartpack Slave n Smartpack Slave 1 System functionality System functionality System functionality with 8 modules Voltage input 1 Voltage inputs 2 Voltage inputs 8 Symmetry inputs 8 (2x4x12V) Symmetry inputs 16 (4x4x12V) Symmetry inputs 64 (16x4x12V) Current inputs 2 Current inputs 4 Current inputs 2x8 Temperature inputs 2 Temperature inputs 4 Temperature inputs 2x8 General purpose inputs 6 General purpose inputs 12 General purpose inputs 6x8 Load fuse input 1 Load fuse input 2 Load fuse input 1x8 Batt fuse input 2 Batt fuse input 4 Batt fuse input 2x8 Relay outputs 6 Relay outputs 12 Relay outputs 6x8 Contactor control 2+ Contactor control 4+ Contactor control 2+x8 Slide 47 of 23 29.04.2013 . Conectividad Latched Contactors A latching contactor changes state only when a reversed pulse voltage is applied to the coil. Slide 48 of 23 29.04.2013 Protection Diode . PowerSuite > Explorer oriented easy to use PC SW > USB gives simple access.04. Slide 49 of 23 29.2013 . > Wide functionality with clear graphic presentation. Smartpack Front / Power Suite Content > Front menu > Password levels > Alarm ”monitor” > AlarmGroups and output (relay) mapping > ”Programmable” inputs > Event log > Operational mode and ”Critical” conditions > Low Voltage Disconnect (LVD) > Battery functions • Battery discharge test • Test results • Battery tables • Temp. comp & Charge curr. limitation • Test results • Special monitors • Boost • Symmetry > Calibration & shunt Scaling > Rectifier ID’s > Mains measurement > PowerSuite installation and basic introduction Slide 50 of 23 29.04.2013 . envíe el numero de serie a fabrica. Slide 51 of 23 29.2013 .04.Niveles de acceso > Smartpack/PowerSuite password • 4 digit pin-code > Nivel de usuario • No password > Novel de Servicio • Password: ”0003” (default) > Nivel de Fabrica • Password: > Si perdió la contraseña de servicio. para poder enviar ”PUK-code” de retorno. 1 Voltage limit for Low Voltage Load Disconnect (LVLD) .details Slide 52 of 23 29.04.Smartpack menu frontal > VoltageInfo .2013 Option Description NomVolt Nominal output voltage BoostVolt Battery boost-charging voltage LowBatt1 Voltage limit for MinorLow Battery Alarm LowBatt2 Voltage limit for MajorLow Battery Alarm HighBatt1 Voltage limit for MinorHigh Battery Alarm HighBatt2 Voltage limit for MajorHigh Battery Alarm LVBD Voltage limit for Low Voltage Battery Disconnect (LVBD) LVLD 1. 04.2013 Option Description NoOfRects.details Slide 53 of 23 29.Smartpack menu frontal > RectifierInfo . RectCurrent Rectifier current RectSerialNumber Rectifier ID and serial number Rect. Number of rectifiers installed in the system.PrimaryVolt Rectifier input mains voltage Rectifier Status Rectifier status Rectifier Temp Rectifier temperature . 04.Alarm ”monitor” cont’ Slide 54 of 23 29.2013 . 2013 .Entradas programables > 6 entradas digitales programables. Slide 55 of 23 29.04. Not all activates a function (yet.2013 .) • Description may be changed > Description and Event text listed in Event log Slide 56 of 23 29..Entradas programables > Input ”Monitor” • Event is selectable in ”drop-down-list” .04.. 04. se sobre escribe el más viejo evento. > El registro se almacena en EEPROME Ejemplo Slide 57 of 23 29.2013 • 27-09-2005 (Date ”dd-mm-yyyy”) • 17:15 (Time ”hh:mm”) • Battery Voltage (Monitor name/Description) • MinorLow: ON (Event status in monitor) . Cuando el registro esta lleno.Log de Eventos > Smartpack front: ”DisplayMessages” > PowerSuite: “Event Log” > El Smartpack controlador puede almacenar hasta 1000 eventos cronológicos. > Volver a conectar se toma cuando el sistema “NO es crítico” y: .2013 . si es activo.El voltaje de la batería esta debajo del limite. .04. > Default hysteresis entre reconexión y desconexión es de 4V Slide 58 of 23 29.Desconexión por bajo voltaje (LVD) > Se toma la acción de desconexión cuando el sistema está en “crítico” y: .Delay time ha expirado.El voltaje de la batería está sobre límite. Si se alcanza el tiempo de la prueba las baterías son buenas .Funciones de Batería Test de Descarga > Smartpack Tiene dos tipos de test batería. .Si se alcanza el voltaje final de las baterías primero son malas > Tres diferentes modos de test son posibles (para ambos tipos) Slide 59 of 23 29. • Normal – usa la tabla de batería • Simplificado – usa el voltaje final y el tiempo a criterio . fecha y el intervalo de periodos.04.2013 • Manual: Empiezo y parada por una entrada manual • Periódico/Intervalo: Programado por tiempo. 20 min (300 min < test duration < 600 min) .2013 .Funciones de Batería Resultado del Test > Hasta 10 diferentes resultados de la prueba de descarga almacenados en la EEPROM • Empiezo Fecha [mm/dd/yyyy] • Tiempo Final [hh:mm] • Tipo de Test [Manual/Periodic/Automatic] • Tabla de batería • Duración del Test [m] • Corriente de descarga [Ah] • Voltaje final [V] • Calidad Calculada [%] • Resultado del Test > Datos Registardos • Corriente de bateria(1 & 2) • Voltaje de bateria • Temperatura(1 & 2) • Voltaje de simetria (8) > Los Resulatados pueden ser vistos haciendo click en el icono de batería en la columna del resultado de la prueba • First 10 min and last 10 min logging are done every minute • In between every .04.10 min (test duration < 300 min) .40 min (600 min < test duration < 1200 min) Slide 60 of 23 29. Muchas tablas de batería pueden ser almacenadas en la PC y facil de uploaded al Smartpack con PowerSuite > What is Eltek Std? • Slide 61 of 23 29.Funciones de Batería Tabla de Batería > Smartpack puede almacenar dos tablas de batería definida por el usuario con: • Tiempo [min] • Corriente de Bateria 1.9V/cell Voltaje final alto [A] • Corriente de Bateria 1.75V/cell Voltaje final bajo [A] > NOTE.2013 Es el promedio de valores no cambiables de los diferentes tipos de fabricantes de baterías. .04. 04.Funciones de Batería Tabla de Batería > Configuración de la tabla de baterías por Powersuite Slide 62 of 23 29.2013 . 2013 .Funciones de Batería Tabla de Batería Slide 63 of 23 29.04. Funciones de Batería Temp. & Curr.2013 • Dos limitación configurables (v1. . Lim. > Compensacion por temperatura • Slope • Ref. Comp. temp • Min comp. volt • Max comp. volt > Limitación corriente de batería Slide 64 of 23 29.02) • Planta generadora.04. indicando con una entrada digital. 5 55 54.2013 o Temperature T [ C] Max Comp. volt Slide 65 of 23 29.5 Min Comp. Comp. & Curr. Volt .Funciones de Batería Temp.5 54 Slope 53.04. Lim.5 53 52. Output Voltage [Vdc] 55. Recharge Load current Mains Slide 66 of 23 29. Lim. Comp.3*C10 Float current Mains OK Mains failure Mains OK.04. & Curr.Battery Current (A) Funciones de Batería Temp. Battery current limit [A] = 0.2013 Mains OK . 04.2013 .Rectifier ID’s cont’ > Reset number of rectifiers Slide 68 of 23 29. Soluciones de Sistemas Cuanta potencia usted necesita ? > . 04.Mas densidad de potencia Up to 8000W per 1PR shelf 1U Slide 70 of 23 29.2013 . 2013 Smartpack in Distribtuion .04.Montaje Flexible Smartpack mounting options Smartpack in PR Slide 71 of 23 29. 04.2013 (exc rectifiers) 1U Distribucion + 1 PR 8000W (166A@48V) Smartpack 2 x 100A Breakers de Bateria 6 x 2–32A Breakers de Carga 2 x LVD (150A) .Soluciones Integradas Soluciones Integradas 2U Incluye (up to) : 5 kg Slide 72 of 23 29. 04.Soluciones Integradas Solucion Integrada 5 .2013 (exc rectifiers) 4U Distribucion + 1-4 PR 32000W (660A@48V) Smartpack 6 x 100A Breakers de Bateria* 18 x 2–63A Breakers de carga* 2 x LVD (up to 600A) * Verficar en datasheet por otra for otra configuracion disponible .8U Incluye (up to) : 8 kg Slide 73 of 23 29. 2013 Battery Tray #3 Battery Disconnect #2 Battery Tray #2 Battery Disconnect #1 Battery Tray #1 .04.Soluciones Integradas 23” EIA Seismic Equipment Rack FP2NX-48-9U power system block 7U available equipment space Battery Disconnect #4 Battery Tray #4 Battery Disconnect #3 Slide 74 of 23 29. 96 kW en un solo Gabinete > Max 2000A@48V = 96kW (CAN bus limitation) > Típicamente hasta 4PR por sistema con baterías. Example 32 kW Slide 75 of 23 29.Gabinetes > 8 .04.2013 > Variedad de gabientes disponibles . 04.Solución Gabinete 96kW Slide 76 of 23 29.2013 • Input 230V/400V 3-phase • FP2 2kW rectifiers • Max Output 48V 2000A • Cabinet dimensions: 600x2000x600mm • 2 SmartPacks (Master-Slave) . 04.Gracias!! Slide 77 of 23 29.2013 .