Manual CBG 937



Comments



Description

CBG-937ES Ref.2838 FILTRO-AMPLIFICADOR PROGRAMABLE MULTICANAL 3 0 22 kHz BI-II BIII 24V VHF-UHF 24V SAT UHF1 18V 13V 24V UHF2 24V UHF3 0V BI-II BIII 1 VHF-UHF 2 3 4 5 6 7 8 9 10 UHF Clusters SAT GND CBG-937 Ref.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF + 15V IN Split UHF Exit Output ENG FR Data Data Import Select Filter Test (-30 dB) MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER 21 CENTRALE D'AMPLIFICATION PROGRAMMABLE 39 2 CBG-937 Ref.2838 FILTRO-AMPLIFICADOR PROGRAMABLE MULTICANAL Instrucciones de instalación 0 22 kHz BI-II BIII 24V VHF-UHF 24V SAT UHF1 18V 13V 24V UHF2 24V UHF3 0V BI-II BIII 1 VHF-UHF 2 3 4 5 6 7 8 9 10 UHF Clusters SAT GND CBG-937 Ref.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level Select Filter Data Import + 15V IN Split UHF Exit Output Data SAT ON / OFF Test (-30 dB) CARACTERISTICAS - Diseñado para canales analógicos y digitales, - 1 entrada SAT + 6 entradas terrestres : B I-II / B III / VHF-UHF y 3 entradas divididas sobre 10 clusters UHF programables, - Cada cluster puede tener de 1 a 7 canales del ancho de banda, - Fácil programación usando el pulsador rotativo. Visionado del display de 2 dígitos y los LEDs de cada cluster y cada entrada simplemente presionando el botón. - Función de "COPIA" para poder transferir toda la programación de una unidad a otra reduciendo el tiempo de instalación, - Filtros de gran selectividad, - Baja figura de ruido, - Alta ganancia y gran nivel de salida, - VHF-UHF-SAT amplificadores de banda partida y atenuadores "Interstage" por VHF-UHF, - Regulación automática del nivel de señal o regulación manual mediante atenuador de 30 dB con un 1 dB de paso para la ecualización exacta, - Control de tensión selectiva en las entradas de VHF-UHF y UHF, - Alimentación 0-13-18 V / 0-22 kHz por LNB, - Test de salida -30 dB. 3 Si cae algún líquido en la carcasa accidentalmente. cortinas. No ponga ninguna fuente de calor. encima de la unidad que puedan cubrir las aperturas de ventilación.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel (1) Tierra (2) Ponga el adaptador en su soporte (3) Conecte la fuente de alimentación al amplificador (4) Conecte el cable de red al adaptador (5) Inserte el soporte del adaptador a la carcasa del amplificador Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Data Data Import + 15V Split UHF IN Exit Output Test (-30 dB) 15 cm. en el aparato. MONTAJE 212.2838 Pared 15 cm.. Para prevenir fuego. peligro de descargas: No exponga la unidad a la lluvia o humedad. corto-circuito.INSTRUCCIONES DE SEGURIDAD Leer con cuidado estas instrucciones antes de conectar la unidad. Diríjase a un tecnico cualificado antes de su puesta en marcha. IN Data Data Import + 15V Ventilación 4 IMPORTANTE : Este amplificador está equipado con un ventilador en la parte posterior para mejorar la capacidad de ventilación. No instale el aparato en un lugar con mucho polvo... 15 cm. calefacción. desconecte la corriente. Desconecte el cable de corriente para realizar las diferentes conexiones..). no abra la carcasa del adaptador. manteles. . tales como velas en el aparato. No ponga ningún articulo como papel de periódico. Deje un espacio mínimo de 15 cm alrededor del producto para garantizar la maxima ventilación. CBG-937 Ref. Para evitar riesgos por calentamiento: Instale la unidad en un buen lugar y mantenga una distancia mínima de 15 cm alrededor del aparato con suficiente ventilación. El voltaje viene indicado en el adaptador. La unidad no debe ser expuesta a fuentes de calor (sol. Limpieza : Use solamento un paño seco para limpiar la carcasa.. No utilice disolventes. MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Split UHF Exit Output Test (-30 dB) 15 cm. Para evitar descargas eléctricas. (4) 0 22 kHz BI-II (5) BIII BI-II 24V BIII VHF-UHF 24V 24V 13V 0V 1 VHF-UHF SAT UHF1 18V 2 3 4 5 UHF2 6 7 8 24V 9 UHF3 10 (1) UHF Clusters SAT GND (3) (2) 185 mm. No ponga objetos con líquido. Mantenimiento : Para reparaciones o mantenimiento diríjase a personal cualificado. Instale la unidad en un lugar seco sin filtraciones o condensaciones de agua. No la exponga a salpicaduras.5 mm. CBG-937 Ref. (5) Ventilación 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 SAT 4 24V 5 UHF2 6 7 8 UHF3 24V 9 10 UHF Clusters GND 15 cm. . 6 .Presione el botón para confirmar. LED vuelve a ponerse verde. canal.Presione el botón durante más de 3 segundos para acceder al sistema de programación. Un punto aparece en el display. . gire el botón para seleccionar el parámetro (entrada. seguido de un punto. = LED verde = LED rojo .Presione el botón para entrar al modo seleccionado. El modo está indicado con un LED de color verde. . . …) LEDs Entradas y Clusters I-II III VHF-UHF 1 2 3 4 5 6 7 8 9 10 UHF clusters Display . Salida modo programación Repita esta sección para ajustar todos los parámetros Nota : El amplificador pasará a modo "stand-by" y aparecerá un punto en el display pasado un minuto sin usar el botón. 3sec. El LED es ahora rojo.OPERACIONES Todos los parámetros son fijados con el botón de presión rotativo.Presione el botón para confirmar la programación.Gire el botón para seleccionar el modo Exit (Salir).Realice todas las conexiones necesarias y conecte el amplificador a la corriente. cluster. La versión del software sale en el display.Gire el botón para seleccionar el modo deseado. .Dentro del modo. Exit El LED está verde. nivel. . Programación Entrada modo de programación . Cada función y parámetros se muestran mediante un display de 2 dígitos y diferentes LEDs. .7. Hay Tres posibles configuraciones : Entrada Número de cluster(s) UHF1 2 2 2 UHF2 8 7 5 UHF3 0 1 3 UHF1 los clusters están indicados por LEDs AMARILLOS n° 1 y 2 UHF2 los clusters están indicados por LEDs ROJOS n° 3. 7 . Split UHF El LED está verde.9 y 10 UHF3 clusters están indicados por LEDs VERDES n° 8.9 y 10 Para ajustar el número de clusters por entrada : . . .UHF1 esta ajustado para 2 clusters. Split UHF El LED está rojo.Gire el botón para ajustar una configuración : I-II III VHF-UHF 1 2 3 4 5 6 7 8 9 10 UHF clusters Indicador cluster UHF1 Indicador cluster UHF2 Indicador cluster UHF3 .5.Presione el botón para confirmar. UHF2 y UHF3 estan configurados para diferentes numeros de clusters.4. Split UHF Notas : . si sólo necesitas un cluster para UHF1. ajuste el segundo cluster en el canal 00 para desconectarlo (vea el párrafo siguiente capítulo "Ajustando canales / clusters").8.Cada cluster puede ser desconectado (Función de Aparcado).PROGRAMACION CLUSTERS Ajustar clusters / Entradas UHF . Por ejemplo.Gire el botón para seleccionar el modo Split UHF (Entrada UHF).6.El amplificador tiene 3 entradas UHF las cuales están divididas sobre 10 clusters. El LED está verde.Presione el botón para confirmar. Ajustando canales / clusters Cada cluster tiene un ancho de banda el cual puede ser programado desde 1 a 7 canales : Para ajustar el canal o canales por cluster : En el ejemplo siguiente el cluster 1 es ajustado para los canales 22 a 26 . Start Channel El LED está verde. . Display .Presione el botón para confirmar.Dentro del modo.Presione el botón para entrar en el modo seleccionado. I-II III VHF-UHF 1 2 3 4 5 6 7 UHF clusters LED n° 1 .Gire el botón para seleccionar el modo Stop Channel (Canal Final). Display .Gire el botón para seleccionar modo Start Channel (Canal Inicial).Gire el botón para seleccionar el canal inicial.Gire el botón para seleccionar el modo Select Filter (Selección Filtro). . = LED verde = LED rojo . Select Filter El LED está ahora ROJO.Presione el botón para confirmar. . Start Channel El LED está ahora en ROJO. Repita esta sección para ajustar todos los clusters. que se va a ajustar.Presione el botón para confirmar. Select Filter El LED está verde. 8 8 9 10 . gire el botón para seleccionar el cluster.Presione el botón para entrar en el modo seleccionado.Gire el botón para seleccionar el canal final. Stop Channel El LED está ahora ROJO.Presione el botón para entrar en el modo seleccionado. Stop Channel El LED está verde. . Select Filter Modo está indicado con el LED de color VERDE. . Start Channel El LED está verde. . . Stop Channel El LED está verde. Notas : .Modo Monocanal Cuando el canal de comienzo es seleccionado. Start Channel . Start Channel c22 c26 Cluster Cluster 1 = c 22 a c 26 Cluster 2 = c 25 a c 29 canal c25 c29 Cluster 2 9 .Función de aparcado : Para desconectar el cluster. Start Channel . seleccione Start Channel (Canal Inicial) y ajuste canal 00. el display emite un punto parpadeante de forma intermitente. el canal finalización es ajustado automáticamente con el mismo valor.Si hay clusters solapados. El Stop Channel (Canal Final) ira automáticamente al canal 00. Gire el botón para seleccionar el modo Select Filter (Selección Filtro). Cluster ajustado al canal 22.El display muestra los canales ajustados. Ejemplos : Cluster desconectado. 10 .Gire el botón para seleccionar el cluster que desea comprabar. Select Filter El LED está verde.Presione el botón para entrar en el modo seleccionado.Presione el botón para salir.Para comprobar los ajustes de canal por cada cluster. . Select Filter El LED está verde. . . Cluster 22 y 26 alternativamente: cluster ajustado desde el 22 al 26. Select Filter El LED está ahora ROJO. I-II III VHF-UHF 1 2 3 4 5 6 7 8 9 10 UHF clusters . . 11 . El nivel se ajusta automáticamente por cada cluster. El display muestra el valor de la atenuación.El ajuste automático fija el nivel de salida del cluster a 100 dBµV (para una señal de entrada entre 50 y 80 dBµV). el LED parpadeará lentamente después del procedimiento de ajuste automático.El LED de cada cluster muestra el estado de la ecualización. . 1 2 3 4 5 6 7 8 9 10 UHF clusters El LED activado indica el cluster que actualmente se está procesando. 1 2 3 4 5 6 7 8 9 10 UHF clusters Apagado: cluster desconectado Encendido: Nivel correcto Parpadeo lento: Nivel bajo Parpadeo rápido: Nivel demasiado fuerte Notas: .Presione el botón durante más de 3 segundos para iniciar la función Auto Level. 3sec. . Si el nivel de entrada es inferior a 50 dBµV. el procedimiento ha terminado. Ajuste automático del nivel. . Este proceso durará aprox. Los niveles de BI-II / BIII /VHF-UHF / SAT no se procesan con la función de Nivel Automático. Se puede reajustar en un rango de -9 a +10 dB para obtener un nivel de salida entre 91 y 110 dBuV (ver "Ajuste general del nivel de UHF). Auto Level El LED está en VERDE. Auto Level El LED está VERDE . . Reajustar el nivel de entrada (atenuación o ganancia) si fuera necesario.El atenuador general se fija a 0 dB después del ajuste automático. . indicando a continuación los canales y clusters que se están ecualizando. 1 a 2 minutos.AJUSTE DE NIVEL Los niveles son ajustados manualmente por cada entrada y/o automáticamente para los clusters.Gire el botón para seleccionar el modo Auto Level (Nivel Automático). Si el nivel de entrada es mayor a 80 dBµV.El nivel de cada cluster se puede ajustar de forma independiente (ver "Ajuste manual del nivel") IMPORTANTE: La indicación de los 10 LEDs no cambiará después del ajuste manual de los clusters.Cuando el LED se ponga en VERDE. Auto Level El LED está ahora ROJO. el LED parpadeará rápidamente. 12 . Para ajustar los niveles generales de UHF.Cuando el nivel de los clusters ha sido ecualizado individualmente.Presione el botón para confirmar. el nivel general de las señal de UHF (clusters y parte de la entrada VHF-UHF) pueden ser ajustados en pasos de 1 dB desde +10 dB hasta -9 dB. Select Filter El LED está ahora ROJO. . I-II III VHF-UHF 1 2 3 4 5 6 7 8 9 10 UHF clusters Todos los LEDs están activados .Presione el botón para entrar en el modo seleccionado.Gire el botón para ajustar el nivel general. Select Filter El LED está verde. Seleccione todos los clusters y VHF-UHF. .Gire el botón para seleccionar el modo Manual Level (Nivel Manual). Select Filter El LED está verde. . .Gire el botón para seleccionar el modo Select Filter (Selección Filtro). Ajuste general del nivel de UHF.Presione el botón para entrar en el modo seleccionado. . variable desde +10 dB hasta -9 dB. Manual Level El LED está verde.Presione el botón para confirmar. . Manual level El LED está verde. Manual Level El LED está ahora ROJO.Gire el botón para seleccionar toda la UHF. . . I-II III VHF-UHF 1 2 3 4 5 6 7 UHF clusters LED está activado .Presione el botón para entrar el modo seleccionado. .Seleccione la entrada o cluster deseado. Select Filter El LED está verde.Gire el botón para seleccionar BI-II.Presione el botón para entrar en el modo seleccionado. . Repita esta sección para ajustar todos los niveles 13 8 9 10 . Para ajustar manualmente el nivel. Manual Level El LED está ahora ROJO.Presione el botón para confirmar. . . . Select Filter El LED está ahora ROJO.Gire el botón para ajustar el nivel manualmente.Presione el botón para confirmar. Manual Level El LED está verde.Gire el botón para seleccionar el modo Manual Level (Nivel Manual). Ejemplo : ajustar el nivel de BI-II.AJUSTE DE NIVEL Los niveles son ajustados manualmente por cada entrada y / o automáticamente para los clusters. Ajuste manual del nivel.Gire el botón para seleccionar el modo Select Filter (Selección Filtro). Manual Level El LED está verde. se puede variar desde 20 dB hasta 0 dB (30 dB hasta 0 dB para clusters). Select Filter El LED está verde. . . I-II III VHF-UHF 1 2 3 4 5 6 7 8 UHF Clusters SAT LED está activido El display muestra el status "ON" o "OFF" . Select Filter El LED está ahora rojo .Presione el botón para confirmar. Select Filter El LED está verde.Funcionamiento SAT Selectionar la entrada SAT.Gire el botón para seleccionar SAT. .Gire el botón para seleccionar el modo Select Filter (Selección Filtro). Select Filter El LED está verde .Presione el botón para entrar en el modo seleccionado. 14 9 10 . 9 dB . Manual Level El LED está ahora rojo .Presione el botón para entrar en el modo seleccionado.Gire el botón para seleccionar el modo SAT Slope (Pendiente SAT). 2300MHz . variable desde 20 dB hasta 0 dB.Gire el botón para ajustar el nivel.Gire el botón para ajustar la pendiente.Presione el botón para entrar en el modo seleccionado. SAT Slope El LED está ahora rojo .Para ajustar la ganancia. SAT Slope El LED está verde . . Manual Level El LED está verde Para ajustar la pendiente. .Gire el botón para seleccionar el modo Manual Level (Nivel Manual). .Presione el botón para confirmar. Pendiente . variable desde 0 dB hasta -9 dB.0 dB .Presione el botón para confirmar. 950MHz SAT Slope El LED está verde 15 Freq. Manual Level El LED está verde . Select Filter El LED está ahora rojo .Gire el botón para seleccionar el modo SAT ON / OFF . .Presione el botón para entrar en el modo seleccionado. Select Filter El LED está verde .Para desactivar el amplificador SAT .Gire el botón para desactivar el amplificador SAT. I-II III VHF-UHF 1 2 3 4 5 6 7 UHF Clusters SAT LED está activido . SAT ON/OFF El LED está ahora rojo .Gire el botón para seleccionar SAT.Presione el botón para entrar en el modo seleccionado. Select Filter El LED está verde . SAT ON/OFF El LED está verde 16 8 9 10 .Presione el botón para confirmar. SAT ON/OFF El LED está verde .Gire el botón para seleccionar el modo Select Filter (Selección Filtro).Presione el botón para confirmar. FUNCION COPIA Esta función permite transmitir todos los ajustes desde una unidad a otra unidad. Todas las acciones deben ser realizadas en la unidad ESCLAVA. La unidad MAESTRA permanece en Stand-by. 0 22 kHz BIII BI-II BIII 24V VHF-UHF 24V 0 22 kHz UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 4 24V 5 UHF2 6 7 8 24V 9 UHF3 BI-II BIII 10 BI-II BIII 24V VHF-UHF UHF Clusters SAT 24V UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 4 24V 5 UHF2 6 7 8 24V UHF3 9 GND GND CBG-937 Ref.2838 CBG-937 Ref.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level Stop Channel SAT Slope Auto Level Start Channel SAT ON / OFF Auto Level SAT ON / OFF Select Filter Data Import Split UHF Exit Output Data IN Manual Level SAT Slope Start Channel Select Filter + 15V 10 UHF Clusters SAT Test Data Import + 15V IN Split UHF Exit Output (-30 dB) Esclava Data BI-II Test (-30 dB) Maestra Datos - Conecte la unidad Maestra y la Esclava con un cable DSUB9 macho/macho cruzado. - Después conecte la corriente de las unidades. La version del software aparece en el display, seguido de un punto. - Presione el botón durante más de 3 segundos para entrar en el modo de programación. 3sec. - Gire el botón para seleccionar el modo Data Import. Data Import El LED está verde. - Presione el botón para entrar en el modo seleccionado. Data Import El LED está ahora ROJO. AL aparece en el display. - Presione el botón para confirmar Data Import. La version del software aparece en el display, seguido de un punto. Nota : Si ocurre un problema durante la transmisión de datos el display mostrará un mensaje de error : Los posibles causas son: el cable no es el adecuado, no hay cable, mal contacto en los pins... 17 RESET GENERAL Esta función puede reestablecer los clusters y los atenuadores al valor cero. - Desconecte el cable de red. 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 1 VHF-UHF SAT 18V 13V 0V 2 3 4 24V 5 UHF2 6 7 8 24V 9 UHF3 10 UHF Clusters SAT GND CBG-937 Ref.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Data Data Import + 15V IN Split UHF Exit Output Test (-30 dB) - Mantenga el botón pulsado. - Hasta que haya conectado de nuevo el cable de red. 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 1 VHF-UHF SAT 18V 13V 0V 2 3 4 24V 5 UHF2 6 7 8 24V 9 UHF3 10 UHF Clusters SAT GND CBG-937 Ref.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Auto Level Start Channel SAT ON / OFF Select Filter 15V IN Split UHF Exit Output Data Data Import + Test (-30 dB) La versión del software sale en el display seguido de un punto. - Suelte ahora el botón. 18 At. 20 dB BI-II 19 TAP VHF UHF DC BIII VHF-UHF 1 2 UHF 1 DC At. 30 dB 3 DC UHF 2 4 5 6 7 9 SAT Alta potencia At. general Att. 20 dB Salida VHF UHF TAP 8 10 UHF 3 Nivel auto Test -30 dB DC SAT Pendiente 9 dB At. 20 dB 0-22 kHz 0/13/18 V DIAGRAMA DE BLOQUES ESPECIFICACIONES TECNICAS Entradas BI-FM BIII VHF-UHF UHF 1 UHF 2 UHF 3 SAT Rango de frecuencia (MHz) 47-108 174-240 47-240 + 470-862 470-862 470-862 470-862 950-2300 8-56 (1 a 7 canales / cluster) Configuración de los - - - clusters 2 8 0 2 7 1 2 5 3 - Ganancia (dB) 35 40 40 55 40 Atenuador (dB) 20 20 20 30 20 - - - Ajuste de pendiente (dB) Nivel general ajustable UHF (dB) - - Figura de ruido (dB) 5 5 - - - 9 - - +10 dB a -9 dB 5 9 6 Nivel máximo Entrada (dBµV) 80 80 80 80 90 Nivel máximo Salida (dBµV) 118 118 VHF:118 / UHF:123 123 116 - - - 10 dB / 10 MHz Selectividad Perdida de retorno SAT / TERR. / SAT > 25 dB 265 x 220 x 95 Todas las especificaciones pueden ser sujetos a cambios sin previo aviso. SAT: -35 dB / IM3 20 . > 30 dB >10 Entrada / Salida (dB) > 10 > 10 - - Paso de corriente selectivo > 10 24 V > 10 > 10 > 10 24 V 24 V 24 V 100 mA en total Test de salida (dB) -30 Transferencia datos Conector DSUB9 Alimentación 0-13-18 V / 300 mA y 0-22 kHz 230 V~ / 15 V DC / 45 VA Temperatura de funcionamiento (C°) -5 a +50 Dimensiones (mm.: -54 dB / IM3 TERR.) * TERR. .CBG-937 Ref. . . .High gain and output power.13 . . . .VHF-UHF-SAT split band amplifiers with interstage attenuators for VHF-UHF.Automatic leveling of signal or manual by attenuator with 1 dB step for accurate equalization . .2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level Select Filter Data Import + 15V Split UHF IN Exit Output Data SAT ON / OFF Test (-30 dB) FEATURES . .0 . .Low noise figure amplifiers.'COPY' function in order to transfer all settlements from one unit to another reducing time of installation.High selectivity filters.Selectable remote power on VHF-UHF and UHF inputs. 21 .Easy programming by using one rotary / push button viewed on 2 digits display and LEDs for each cluster and each input.22 kHz remote power for LNB.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Installation instructions 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 18V 1 VHF-UHF SAT 13V 0V 2 3 4 24V 5 UHF2 6 7 8 24V 9 UHF3 10 UHF Clusters SAT GND CBG-937 Ref.1 SAT input + 6 Terrestrial inputs : B I-II / B III / VHF-UHF and 3 UHF inputs splitted over 10 UHF programmable clusters.18V / 0 .Designed for both digital and analogue Satellite and Terrestrial channels.Each cluster can have 1 to 7 channels bandwidth.-30 dB Test output. . table-cloths. To avoid any risk of overheating: Install the unit in a well aery location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation. Refer to qualified technician before it's further operation. Do not use solvent. Mounting 212. CBG-937 Ref.. The operating voltage is indicated on the adapter. Cleaning : Only use a dry soft cloth to clean the cabinet. on the apparatus. 15 cm. such as vases. Do not place any naked flame sources. To prevent fire.SAFETY INSTRUCTIONS Read carefully these instructions before connecting the unit. CBG-937 Ref. IN Data Data Import + 15V Ventilation 22 IMPORTANT : this amplifier is equiped with a fan on the back side to improve cooling capacity. on the unit that might cover the ventilation holes. do not open the housing of adapter..2838 Wall 15 cm. short circuit. Do not place objects filled with liquids. MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Split UHF Exit Output Test (-30 dB) 15 cm. (5) Ventilation 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 4 24V 5 UHF2 6 7 8 UHF3 24V 9 10 UHF Clusters SAT GND 15 cm. Install the unit in a dry location without infiltration or condensation of water. shock hazard: Do not expose the unit to rain or moisture. (4) 0 22 kHz BI-II (5) BIII 24V VHF-UHF 24V SAT UHF1 18V 13V 24V UHF2 24V UHF3 0V BI-II BIII 1 VHF-UHF 2 3 4 5 6 7 8 9 10 (1) UHF Clusters SAT GND (3) (2) 185 mm.. If any liquid should accidentally fall into the cabinet. . Do not install the product in a dusty place. Do not expose it to dripping or splashing. Leave a minimum space of 15 cm. Servicing : For repairing and servicing refer to qualified personnel. disconnect the power plug.. heater. To avoid electrical shock. Do not place any items such as newspapers.).. Pull out power plug to make the different connections of cables. around the product to guarantee a maximum ventilation.5 mm. on the apparatus. The unit must not be exposed to any source of heat (sun. such as lighted candles.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel (1) Earthing (2) Place the adapter in its holder (3) Connect the power supply to the amplifier (4) Plug the mains cable to the adapter (5) Click the adapter holder to the amplifier Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Data Data Import + 15V Split UHF IN Exit Output Test (-30 dB) 15 cm. curtains . . ) Input and Cluster LEDs I-II III VHF-UHF 1 2 3 4 5 6 7 8 9 10 UHF Clusters Display .Push the button to confirm. A dot is displayed.Push the button to confirm the parameter setting. .Push on the rotary button for more than 3 seconds to enter into programming mode.Turn the button to select the desired mode.Inside the mode.Make all the necessary connections and connect amplifier to mains.. Mode is indicated with a GREEN colored LED. channels. Note : The amplifier will go in "stand-by" and will display a dot after 1 minute if the rotary / push button is not activated.. Programming The software version is displayed. . . 24 . The LED is now RED colored. = green LED = red LED . 3sec.Push the rotary button to enter the selected mode. Each function and parameters are shown on 2 digits display and different LEDs . Exit programming mode . LED returns to a GREEN color. Repeat this section to set all parameters Exit The LED is green. turn the button to select the parameter (input.OPERATION All parameters are set with the rotary push button. followed by a dot. . cluster. level.Turn the button to select Exit mode. Enter programming mode . UHF1 is set for 2 clusters. 9 and 10. 7. There are three possible configurations : Input Number of cluster(s) UHF1 2 2 2 UHF2 8 7 5 UHF3 0 1 3 UHF1 clusters are indicated by the YELLOW LEDs n° 1 and 2.The amplifier has 3 UHF inputs which are splitted over 10 clusters. For example if you only need one cluster for UHF1. .Push the button to confirm. 4. 25 . 6.Turn the button to select Split UHF mode. . UHF2 and UHF3 are set for different number of cluster(s). Split UHF The LED is red. To set the number of cluster(s) per input : . . 5. Split UHF Notes : .Push the button to confirm.Turn the button to set one configuration : I-II III VHF-UHF 1 2 3 4 5 6 7 8 9 10 UHF Clusters UHF1 cluster indicator UHF2 cluster indicator UHF3 cluster indicator . UHF2 clusters are indicated by the RED LEDs n° 3. 8.Each cluster can be switched off (Park function). Split UHF The LED is green. 9 and 10. UHF3 clusters are indicated by the GREEN LEDs n° 8.CLUSTER PROGRAMMING Setting clusters / UHF input . The LED is green. set the second cluster on channel 00 to switch it off (see following paragraph "Setting channels / cluster"). Select Filter = green LED Mode is indicated with a GREEN colored LED. = red LED . Stop Channel The LED is green.Turn the button to select the Start Channel mode. .Push the rotary button to enter the selected mode. Start Channel The LED is green.Push the button to confirm.Setting channels / cluster Each cluster has a bandwidth which can be programmed from 1 to 7 channels : To set the channel(s) per cluster : In the following example cluster 1 is set for channel 22 to channel 26. . . . Start Channel The LED is green.Push the rotary button to enter the selected mode.Turn the button to select the stop channel Display . Stop Channel The LED is now RED colored. . . Select Filter The LED is green. Start Channel The LED is now RED colored. Select Filter The LED is now RED colored. I-II III VHF-UHF 1 2 3 4 5 6 7 UHF Clusters LED n° 1 . Repeat this section to set all clusters 26 8 9 10 . turn the button to select the cluster to be set.Turn the button to select the start channel Display . Stop Channel The LED is green.Turn the button to select the Select Filter mode.Push the button to confirm. .Turn the button to select the Stop Channel mode.Push the button to confirm.Inside the mode. .Push the rotary button to enter the selected mode. Start Channel .Notes : . Start Channel ch22 ch26 cluster 1 Cluster 1 = ch 22 to ch 26 Cluster 2 = ch 25 to ch 29 channel ch25 ch29 cluster 2 27 . the Stop Channel is automatically set at the same value.Single channel mode : When the Start Channel is selected. Start Channel . the display dots will blink alternately.Park function : to switch off the cluster. select Start Channel and set 00. The Stop Channel goes automaticaly to 00.If there are overlapping clusters. .The display shows the channels which have been set. Examples : Cluster is parked.To check the channel settings of each cluster : . Blinking 22 and 26: cluster is set from 22 to 26. . 28 .Turn the rotary button to select Select Filter. Select Filter The LED is GREEN.Turn the button to choose the cluster to be checked. Select Filter The LED is now RED colored.Push the rotary button to enter the selected mode. 1 2 3 4 5 6 7 8 9 10 UHF Clusters . Cluster is set to channel 22. .Push the button to exit. Select Filter The LED is GREEN. It can be adjusted from -9 to +10 to get a level between 91 to 110 dBµV (see "General UHF level setting"). . Adjust the input level (attenuation or amplification) if necessary. The display shows the value of attenuation. 1 2 3 4 5 6 7 8 9 10 UHF Clusters LED off : parked cluster LED on : correct level LED blinking slowly : signal is too weak LED blinking rapidly : signal is too strong Notes : . 29 . 1 2 3 4 5 6 7 8 9 10 UHF Clusters The actived LED indicates the cluster which is being processed.Each cluster's LED shows the status of equalization.When the LED is GREEN.The automatic level adjustment set the output level of the clusters at 100 dBµV (for an input level between 50 to 80 dBµV).LEVEL ADJUSTMENT Levels are manually set for each input and / or automatically for the UHF clusters.The level of each cluster can be adjusted independently (see "manually level setting). the procedure is finished. .Turn the button to choose the Auto Level. depending on the number of channels and clusters to be equalized. . If the input level is higher than 80 dBµV. IMPORTANT : the 10 LEDs indication will not be changed after setting the levels manually. . If the input level is less than 50 dBµV. the LED will blink rapidly after the automatic level adjustment. Automatic level setting The levels of BI-II / BIII / VHF-UHF / SAT are not processed in the Auto Level function. the LED will blink slowly after the automatic level adjustment. Auto level The LED is now RED colored. 3sec.Push the rotary button for more than 3 seconds to start the Auto Level function. .The general attenuator is fixed to 0 after the automatic level adjustment. This procedure will take about 1 to 2 minutes. Auto level The LED is GREEN. Auto level The LED is GREEN. . The level of each cluster is set automatically. Turn the button to select the Manual Level mode. Manual Level The LED is green. . .Turn the button to choose the Select Filter mode. Select Filter The LED is green. .Push the rotary button to enter the selected mode.Push the rotary button to enter the selected mode. Manual Level The LED is green. Manual Level The LED is now RED colored. .After automatic level setting procedure. . Select Filter The LED is now RED colored.Turn the button to select all UHF. Select Filter The LED is green.Turn the button to set the general level. the general level of the UHF signals (clusters and the UHF part of the VHF-UHF input) can be adjusted from +10 dB to -9 dB in steps of 1 dB.Select all the clusters and VHF-UHF. variable from +10 dB to -9 dB.Push the button to confirm. General UHF level setting . . . I-II III VHF-UHF 1 2 3 4 5 6 7 8 UHF Clusters All LEDs are activated . 30 9 10 .Push the button to confirm. Manually level setting To set manually the level.Turn the button to choose the Select Filter mode. . . Select Filter The LED is green. variable from 20 dB to 0 dB (30 dB to 0 dB for clusters). Select Filter The LED is green.Turn the button to select BI-II. Select Filter The LED is now RED colored. I-II III VHF-UHF 1 2 3 4 5 6 7 8 9 UHF Clusters LED is activated .Select the desired input or cluster. . Manual Level The LED is now RED colored. Manual Level The LED is green. . .Turn the button to set manually the level. Manual Level The LED is green. Example : setting the level of BI-II . . Repeat this section to set all levels 31 10 .Push the button to confirm.Push the button to confirm.Push the rotary button to enter the selected mode.Turn the button to select the Manual Level mode. .Push the rotary button to enter the selected mode. SAT OPERATION Select the SAT input. . .Push the rotary button to enter the selected mode. Select Filter The LED is green.Push the button to confirm. Select Filter The LED is green.Turn the button to select SAT.Turn the button to choose the Select Filter mode. 32 8 9 10 . Select Filter The LED is now RED colored. . I-II III VHF-UHF 1 2 3 4 5 6 7 UHF Clusters SAT LED is activated Display shows the status ON or OFF . .To set the Gain.Turn the button to set the level. . Manual Level The LED is green. variable from 0 dB to -9 dB. SAT Slope The LED is green. . Manual Level The LED is now RED colored.Turn the button to select the SAT Slope mode.Push the button to confirm.9 dB 950MHz .Push the rotary button to enter the selected mode.Push the rotary button to enter the selected mode.0 dB . SAT Slope The LED is green. Manual Level The LED is green.Turn the button to select the Manual Level mode. 2300MHz . 33 Freq. .Turn the button to set the slope. To set the Slope.Push the button to confirm. SAT Slope The LED is now RED colored. . . variable from 20 dB to 0 dB. . Slope . Select Filter The LED is now RED colored. Select Filter The LED is green. . .Push the button to confirm.Turn the button to select SAT.Turn the button to switch OFF the SAT amplifier.Push the rotary button to enter the selected mode.Push the button to confirm. . . SAT ON/OFF The LED is green. . I-II III VHF-UHF 1 2 3 4 5 6 7 UHF Clusters SAT LED is activated .Turn the button to select the SAT ON/OFF mode. 34 8 9 10 . Select Filter The LED is green. .To switch OFF the SAT amplifier . SAT ON/OFF The LED is green.Push the rotary button to enter the selected mode.Turn the button to choose the Select Filter mode. SAT ON/OFF The LED is now RED colored. Data Import The LED is now RED colored. bad pin contacts. . followed by a dot. The MASTER unit remains in Stand-by.Push on the rotary button for more than 3 seconds to enter into programming mode.Turn the button to select the Data Import mode. 3sec. Note : If a problem occurs during data transmission the display will show an error message : Possible causes are : wrong type of cable. All actions have to be done on the SLAVE unit. The software version is displayed. Data Import The LED is green.2838 CBG-937 Ref.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level Stop Channel SAT Slope Auto Level Start Channel Auto Level SAT ON / OFF Select Filter Exit Output Data Data Import Split UHF Test Data Import Data SAT ON / OFF IN Manual Level SAT Slope Start Channel Select Filter + 15V + 15V IN Split UHF Exit Output (-30 dB) SLAVE Test (-30 dB) MASTER Data . .Push the rotary button to confirm Data Import. 0 22 kHz BI-II BI-II BIII 24V VHF-UHF BIII 24V SAT 24V 13V 0V 1 VHF-UHF 0 22 kHz UHF1 18V 2 3 4 5 UHF2 6 7 8 24V 9 UHF3 BI-II BIII 10 BI-II BIII 24V VHF-UHF UHF1 18V SAT 24V 13V 0V 1 VHF-UHF UHF Clusters SAT 24V 2 3 4 5 UHF2 6 7 8 24V UHF3 9 10 UHF Clusters SAT GND GND CBG-937 Ref. . 35 . AL is displayed . no cable.COPY FUNCTION This function allows to transmit all settings from one unit to another unit.Push the rotary button to enter the selected mode.Then connect mains to the units. . followed by a dot. The software version is displayed.Connect master and slave unit with a DSUB9 male/male crossed cable. Disconnect the mains power. 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 4 24V 5 UHF2 6 7 8 24V 9 UHF3 10 UHF Clusters SAT GND CBG-937 Ref.Release the button. .until the mains is connected again.GENERAL RESET This function can reset all clusters and attenuators to zero. 36 .Keep on pressing the button.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Data Data Import + 15V IN Split UHF Exit Output Test (-30 dB) .2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter 15V IN Split UHF Exit Output Data Data Import + Test (-30 dB) The software version is now displayed followed by a dot. 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 4 24V 5 UHF2 6 7 8 24V 9 UHF3 10 UHF Clusters SAT GND CBG-937 Ref. . . 30 dB 3 DC UHF 2 4 5 6 7 9 High Power General Att.Att. 20 dB SAT OUT VHF UHF TAP 8 10 UHF 3 Auto Level Test -30 dB DC SAT Slope 9 dB Att. 20 dB 0-22 kHz 0/13/18 V BLOCK DIAGRAM . 20 dB BI-II 37 TAP VHF UHF DC BIII VHF-UHF 1 2 UHF 1 DC Att. input level (dBµV) 80 80 80 80 90 Max. / SAT > 25 dB 265 x 220 x 95 Specifications are subject to change without notice.TECHNICAL SPECIFICATIONS Inputs BI-FM BIII VHF-UHF UHF 1 UHF 2 UHF 3 SAT Frequency range (MHz) 47-108 174-240 47-240 + 470-862 470-862 470-862 470-862 950-2300 8-56 (1 to 7 channels / cluster) Configuration of - - - clusters 2 8 0 2 7 1 2 5 3 - Gain (dB) 35 40 40 55 40 Attenuator (dB) 20 20 20 30 20 - - - Slope adjustment (dB) General UHF level adjustment (dB) - - Noise figure (dB) 5 5 - - - 9 - - +10 dB to -9 dB 5 9 6 Max. SAT: -35 dB / IM3 38 .) * TERR. output level* (dBµV) 118 118 VHF:118 / UHF:123 123 116 - - - 10 dB / 10 MHz Selectivity Return loss IN / OUT (dB) >10 Selectable remote power - >10 SAT / TERR.: -54 dB / IM3 TERR. > 30 dB >10 >10 >10 >10 >10 24 V 24 V 24 V 24 V 0-13-18 V / 300 mA - 100 mA in Total Test output (dB) and 0-22 kHz -30 Data transfert DSUB9 connector Power supply 230 V~ / 15 V DC / 45 VA Operating temperature (C°) -5 to +50 Dimensions (mm. 39 Ref. .Sortie Test -30 dB. .Programmation facile par un bouton poussoir rotatif avec affichage sur 2 digits et LED sur chaque entrée et chaque filtre.Amplification séparée VHF-UHF-SAT et atténuateurs inter-étage VHF et UHF.CBG-937 CENTRALE D'AMPLIFICATION PROGRAMMABLE Notice d'installation 0 22 kHz BI-II BIII 24V VHF-UHF 24V SAT UHF1 18V 13V 24V UHF2 24V UHF3 0V BI-II BIII 1 VHF-UHF 2 3 4 5 6 7 8 9 10 UHF Clusters SAT GND CBG-937 Ref. .1 entrée SAT + 6 entrées terrestres pour l'amplification des signaux B I-II / B III / VHF-UHF avec filtrage / égalisation de 10 filtres provenant de 3 entrées UHF paramétrables. .Egalisation automatique et manuelle des signaux / atténuateur réglable au pas de 1 dB.Développée pour la réception des canaux numériques et analogiques .Filtres de grande sélectivité. .Faible facteur de bruit.Fonction "copie" pour le transfert de tous les paramètres d'un amplificateur vers un autre.Téléalimentation LNB 0-13-18 V / 0-22 kHz.2838 .2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Data Data Import + 15V IN Split UHF Exit Output Test (-30 dB) SPECIFICATIONS . .Chaque filtre peut être programmé sur une largeur de bande de 1 à 7 canaux. . . . . réduisant le temps d'installation. .Téléalimentation 24 Volts sur les entrées VHF-UHF et UHF .Gain élevé et haute puissance. . ne doit être posé sur l'appareil. chauffage... Ne pas l'exposer à des égouttements ou à des éclaboussures d'eau. débrancher le cordon secteur. La plaque signalétique sur l'alimentation indique la tension de fonctionnement...5 mm. Entretien : Utiliser uniquement un chiffon doux et sec pour nettoyer le boîtier. . (4) 0 22 kHz BI-II (5) BIII BI-II 24V BIII VHF-UHF 24V 24V 13V 0V 1 VHF-UHF SAT UHF1 18V 2 3 4 5 UHF2 6 7 8 24V 9 UHF3 10 (1) UHF Clusters SAT GND (3) (2) 185 mm. Ne pas utiliser de solvant. qui puisse couvrir ou boucher les ouvertures d'aération. nappe .CONSIGNES DE SECURITE Lire attentivement ces instructions avant le branchement au réseau électrique. sans infiltration ni condensation d'eau. Afin d'éviter tout risque de surchauffe: Installer le produit dans un endroit bien ventilé et laisser une distance minimale de 15 cm autour de l'appareil pour une aération suffisante. ne pas ouvrir le transformateur d'alimentation. Installer le produit dans un lieu sec. 15 cm. Ne brancher la prise de courant qu'après avoir réalisé le raccordement de tous les câbles. Ne pas placer sur l'appareil des sources de flammes nues telles que des bougies allumées.). CBG-937 Ref. Afin d'éviter tout risque de court-circuit ou de choc électrique: Ne pas exposer cet appareil à la pluie ou à l'humidité.2838 Paroi 15 cm. Aucun objet rempli de liquide tel qu'un vase .. S'adresser à un technicien qualifié avant sa remise en service. Si un liquide tombe accidentellement dans le boîtier. Laisser un espace minimum de 15 cm autour du produit pour garantir une ventilation maximale. Ne pas exposer le produit à une source de chaleur (soleil. IN Data Data Import + 15V Ventilation 40 IMPORTANT : Cet amplificateur est équipé d'un ventilateur sur la partie arrière pour améliorer la capacité de refroidissement. Afin d'éviter tout risque de choc électrique. rideau. L'appareil ne doit pas étre installé en milieu poussiéreux. Ne mettre aucun objet sur le produit tel que journal.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level (1) Borne de terre (2) Placer le transformateur dans son logement (3) Brancher le Jack d'alimentation à l'amplificateur (4) Brancher le cordon secteur sur le transformateur (5) Fixer le boîtier à l'amplificateur SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Data Data Import + 15V Split UHF IN Exit Test (-30 dB) Output (5) 15 cm. MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Split UHF Exit Output Test (-30 dB) 15 cm. Ventilation 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 SAT 4 24V 5 UHF2 6 7 8 UHF3 24V 9 10 UHF Clusters GND 15 cm. Réparation : Toute intervention ou réparation doit être effectuée par un personnel qualifié.. CBG-937 Ref. MONTAGE 212. . cluster.Pousser sur le bouton rotatif pour accéder au mode sélectionné. tourner le bouton pour sélectionner le paramètre (entrée. niveau. = LED verte = LED rouge . La version du software est affichée suivie d'un point. Accéder au mode programmation Programmation 3sec.Tourner le bouton pour sélectionner le mode désiré. 42 Sortir du mode programmation Répéter cette section pour fixer tous les paramètres . La LED retourne à la couleur VERTE .Appuyer sur le bouton pour confirmer. .Appuyer sur le bouton pour confirmer la valeur du paramètre.. Exit La LED est VERTE .Tourner le bouton pour sélectionner le mode Exit. canaux. Chaque fonction et paramètre sont indiqués sur un afficheur à 2 digits et par différentes LED.Appuyer sur le bouton rotatif pendant plus de 3 secondes pour accéder au mode programmation.Dans ce mode. La LED est à présent ROUGE . .FONCTIONNEMENT Tous les paramètres sont réglés par bouton poussoir rotatif.Faire tous les branchements nécessaires et relier l'amplificateur au secteur. Le mode est indiqué par une LED verte. .. . Un point est affiché Remarque : L'amplificateur revient en mode "veille" et affichera un point si le bouton poussoir rotatif n'a pas été actionné dans l'intervalle de 1 minute.) LED Entrée et Filtre Bandes I-II Bande III 1 Bandes 2 I-II-III-IV-V 3 4 5 6 7 8 9 10 Filtres UHF Afficheur . 4. La LED est VERTE Split UHF Remarques : .Chaque filtre peut être désactivé. . Par exemple. 5.PROGRAMMATION DES FILTRES Configurer les filtres par entrée UHF .L'amplificateur possède 3 entrées UHF pour 10 filtres.Tourner le bouton pour sélectionner le mode Split UHF. 9 et 10.Appuyer sur le bouton pour confirmer. si vous n'utiliser qu'un seul filtre pour UHF1. 7. 9 et 10. 8.Appuyer sur le bouton pour confirmer. UHF 2 et UHF 3 peuvent être configurées pour un certain nombre de filtres. Les filtres UHF3 sont indiqués par les LED VERTES n° 8.Tourner le bouton pour choisir une configuration.UHF1 est toujours configurée pour 2 filtres. 43 . il faut régler le second filtre sur le canal 00 pour le désactiver (voir paragraphe suivant: "Configurer les canaux par filtre"). 6. Split UHF La LED est VERTE Split UHF La LED est ROUGE . Il y a 3 configurations possibles : Entrée Nombre de filtre(s) UHF1 2 2 2 UHF2 8 7 5 UHF3 0 1 3 Les filtres UHF1 sont indiqués par les LED JAUNES n° 1 et 2. Pour configurer le nombre de filtre(s) par entrée : . Les filtres UHF2 sont indiqués par les LED ROUGES n° 3. Bandes Bande Bandes I-II III I-II-III-IV-V 1 2 3 4 5 6 7 8 9 10 Filtres UHF Indicateur filtre UHF1 Indicateur filtre UHF2 Indicateur filtre UHF3 . . Dans ce mode. Affichage .Appuyer sur le bouton pour confirmer.Tourner le bouton pour sélectionner le mode Select Filter. Canal de Fin La LED est VERTE Répéter cette section pour régler tous les filtres. tourner le bouton pour sélectionner le filtre à régler. Stop Channel La LED est à présent ROUGE .Tourner le bouton pour sélectionner le Canal le Début.Tourner le bouton pour sélectionner le mode Stop Channel. . Select Filter = LED VERTE Le mode est indiqué par une LED VERTE = LED ROUGE .Appuyer sur le bouton pour confirmer. Stop Channel La LED est VERTE . Select Filter La LED est à présent ROUGE . 44 8 9 10 . Start Channel La LED est VERTE . Canal de Début La LED est à présent ROUGE . Bandes Bande Bandes I-II III I-II-III-IV-V 1 2 3 4 5 6 7 Filtres UHF LED n° 1 .Appuyer sur le bouton rotatif pour accéder au mode sélectionné.Appuyer sur le bouton pour confirmer.Tourner le bouton pour sélectionner le mode Start Channel. Affichage .Appuyer sur le bouton rotatif pour accéder au mode sélectionné. Start Channel La LED est VERTE .Configurer les canaux par filtre Chaque filtre a une largeur de bande programmable de 1 à 7 canaux : Pour configurer les canaux par filtre : Dans l'exemple suivant le filtre 1 est réglé du canal 22 au canal 26.Appuyer sur le bouton rotatif pour accéder au mode sélectionné. Select Filter La LED est VERTE .Tourner le bouton pour sélectionner le Canal de Fin. 29 Filtre 2 45 . 29 Canal c. les points de l'afficheur clignoteront alternativement. 25 c. 22 c.Mode monocanal : lorsque le mode Start Channel est sélectionné.Remarques : . Start Channel c. Start Channel . 26 Filtre 2 = c. Start Channel . 25 à c.Pour désactiver un filtre. 22 à c. le Stop Channel est automatiquement mis sur la même valeur. sélectionner Start Channel et mettre la valeur 00. Le Stop Channel est automatiquement fixé à 00. 26 Filtre 1 Filtre 1 = c.Si les filtres se chevauchent. L'afficheur indique directement les canaux réglés.Dans ce mode.Appuyer sur le bouton pour sortir de ce mode Select Filter La LED est VERTE 46 .Tourner le bouton pour choisir le mode Select Filter. Select Filter La LED est VERTE . 22 et 26 alternativement : filtre réglé de 22 à 26. . 1 2 3 4 5 6 7 8 9 10 Filtres UHF . Select Filter La LED est à présent ROUGE . Exemples : Filtre désactivé Filtre réglé sur le canal 22. choisir le filtre à vérifier.Appuyer sur le bouton rotatif pour accéder au mode sélectionné.Pour vérifier les réglages de chaque filtre : . Chaque LED filtre. . Si le niveau d'entrée est supérieur à 80 dBµV. Auto Level La LED est VERTE .Le niveau de chaque cluster peut être réglé indépendamment (voir paragraphe "Réglage de niveau manuel"). la procédure est terminée. Si le niveau d'entrée est inférieur à 50 dBµV.Lorsque la Led est verte.Tourner le bouton pour choisir le mode Auto Level.Appuyer sur le bouton rotatif pendant plus de 3 secondes pour lancer la procédure de réglage automatique. 47 . Auto Level La LED est à présent ROUGE 3sec.L' atténuateur général est fixé à 0 après le réglage automatique. 1 2 3 4 5 6 7 8 9 10 Filtres UHF La LED allumée indique le filtre en cours de réglage L'afficheur indique la valeur d'atténuation. indique l'état d'égalisation : 1 2 3 4 5 6 7 8 9 10 Filtres UHF Eteinte : filtre désactivé Allumée : niveau correct Clignotement lent : niveau faible Clignotement rapide : niveau trop élevé Remarques : . . la LED clignotera rapidement. .REGLAGE DU NIVEAU TERRESTRE Les niveaux sont réglés manuellement pour chaque entrée et / ou automatiquement pour les filtres UHF. Auto Level La LED est VERTE .Le réglage automatique fixe le niveau de sortie des filtres à 100 dBµV (pour un niveau d'entrée compris entre 50 et 80 dBµV). la LED clignotera lentement après la procédure de réglage automatique. Il peut être réglé de -9 à +10 pour obtenir un niveau compris entre 91 et 110 dBµV (voir paragraphe "Réglage du niveau général"). Le niveau de chaque filtre est réglé automatiquement. Réglage automatique de niveau Le réglage des niveaux BI-II / BIII / VHF-UHF / SAT n'est pas automatique. . IMPORTANT : l'indication des 10 Leds restera inchangée après réglage manuel des filtres. Adapter le niveau d'entrée (atténuateur ou amplificateur) si nécessaire. La procédure dure de 1 à 2 minutes suivant le nombre de canaux et de filtres à égaliser. Réglage du niveau général UHF .Tourner le bouton pour sélectionner le mode Manual Level. Manual Level La LED est VERTE 48 .Tourner le bouton pour régler le niveau général de +10 dB à -9 dB. Bandes Bande Bandes I-II III I-II-III-IV-V 1 2 3 4 5 6 7 8 9 10 Filtres UHF Toutes les LED sont activées .Tourner le bouton pour choisir le mode Select Filter.Sélectionner tous les filtres et VHF-UHF .Appuyer le bouton rotatif pour accéder au mode sélectionné. . Manual Level La LED est VERTE . le niveau général des signaux UHF (filtres et partie UHF de l'entrée VHF-UHF) peut être réglé de +10 dB à -9 dB par pas de 1 dB.Tourner le bouton pour sélectionner tout l'UHF.Appuyer sur le bouton pour confirmer.Appuyer sur le bouton pour confirmer.Appuyer le bouton rotatif pour accéder au mode sélectionné.Après avoir réglé individuellement le niveau de chaque filtre. Select Filter La LED est VERTE . Select Filter La LED est VERTE . Select Filter La LED est à présent ROUGE . Manual Level La LED est à présent ROUGE . Tourner le bouton pour sélectionner le mode Manual Level.Appuyer sur le bouton pour confirmer. Select Filter La LED est à présent ROUGE . .Appuyer sur le bouton pour confirmer. Select Filter La LED est VERTE .Sélectionner l'entrée ou le filtre à régler. Exemple : réglage du niveau BI-II . Bandes Bande Bandes I-II III I-II-III-IV-V 1 2 3 4 5 6 7 8 9 10 Filtres UHF La LED est activée .Tourner le bouton pour choisir le mode Select Filter.Appuyer sur le bouton rotatif pour accéder au mode sélectionné.Appuyer sur le bouton rotatif pour accéder au mode sélectionné.Tourner le bouton pour régler manuellement le niveau de 20 dB à 0 dB (30 dB à 0 dB pour les filtres). . 49 . Manual Level La LED est à présent ROUGE . Manual Level La LED est VERTE Répeter cette section pour régler tous les niveaux. Select Filter La LED est VERTE . Manual Level La LED est VERTE .Tourner le bouton pour sélectionner BI-FM.Réglage de niveau manuel Pour régler manuellement le niveau. . .Tourner le bouton pour sélectionner SAT. Select Filter La LED est VERTE .REGLAGE SATELLITE .Tourner le bouton pour choisir le mode Select Filter.Sélectionner l'entrée SAT. La LED est activée SAT Bandes Bande Bandes I-II III I-II-III-IV-V 1 2 3 4 5 6 7 UHF Clusters l' Afficheur indique ON (marche) ou OF (arrêt). Select Filter La LED est à présent ROUGE .Appuyer le bouton rotatif pour accéder au mode sélectionné. Select Filter La LED est VERTE 50 8 9 10 .Appuyer sur le bouton pour confirmer. Appuyer le bouton rotatif pour accéder au mode sélectionné.0 dB .9 dB 950MHz .Tourner le bouton pour régler la pente.Appuyer le bouton rotatif pour accéder au mode sélectionné. Manual Level La LED est à présent ROUGE . 2300MHz .Tourner le bouton pour régler le niveau. SAT Slope La LED est VERTE . .Appuyer sur le bouton pour confirmer. réglable de 0 dB à -9 dB. Tourner le bouton pour choisir le mode Manual Level.Appuyer sur le bouton pour confirmer. réglable de 20 dB à 0 dB. Manual Level La LED est VERTE Pour régler la pente Tourner le bouton pour choisir le mode SAT Slope. SAT Slope La LED est VERTE 51 Fréq. Manual Level La LED est VERTE . Pente . SAT Slope La LED est à présent ROUGE .Pour régler le gain. Appuyer le bouton rotatif pour accéder au mode sélectionné. Select Filter La LED est à présent ROUGE . Select Filter La LED est VERTE .Appuyer sur le bouton pour confirmer.Appuyer le bouton rotatif pour accéder au mode sélectionné. Select Filter La LED est VERTE Tourner le bouton pour choisir le mode SAT ON / OFF. La LED est activée SAT Bandes Bande Bandes I-II III I-II-III-IV-V 1 2 3 4 5 6 7 UHF Clusters .Pour désactiver l'amplificateur SAT. SAT ON/OFF La LED est à présent ROUGE .Appuyer sur le bouton pour confirmer. Tourner le bouton pour choisir le mode Select Filter.Tourner le bouton pour sélectionner SAT.Tourner le bouton pour désactiver l'amplificateur SAT. . SAT ON/OFF La LED est VERTE . SAT ON/OFF La LED est VERTE 52 8 9 10 . 2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level Stop Channel SAT Slope Auto Level Start Channel Auto Level SAT ON / OFF Select Filter Exit Output Data Data Import Split UHF Test Data Import Data SAT ON / OFF IN Manual Level SAT Slope Start Channel Select Filter + 15V + 15V IN Split UHF Exit Output (-30 dB) ESCLAVE Test (-30 dB) MAITRE Données . La version software est affichée suivie d'un point.Appuyer sur le bouton rotatif pour confirmer le transfert des données. pas de câble raccordé. .Brancher ensuite les amplificateurs au secteur.. Les causes peuvent être un mauvais type de câble.Relier l'amplificateur maître et esclave par un cordon DSUB9 mâle/mâle croisé. l'afficheur indiquera un message d'erreur.FONCTION COPIE Cette fonction permet de transférer tous les paramètres d'un amplificateur vers un autre.Tourner le bouton pour sélectionnr le mode Data Import. Remarque : Si un problème survient lors de la transmission des données. L'amplificateur MAITRE reste en veille.. . 53 . de mauvais contacts. La version software est affichée suivie d'un point. .Appuyer sur le bouton rotatif pendant plus de 3 secondes pour accéder au mode programmation.2838 CBG-937 Ref.. . 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V 0 22 kHz SAT UHF1 18V 24V 13V 0V 1 VHF-UHF 2 3 4 5 UHF2 6 7 8 24V 9 UHF3 BI-II BIII 10 BI-II BIII 24V VHF-UHF UHF Clusters SAT 24V SAT UHF1 18V 24V 13V 0V 1 VHF-UHF 2 3 4 5 UHF2 6 7 8 24V 9 UHF3 10 UHF Clusters SAT GND GND CBG-937 Ref. Toutes les actions se font sur l'amplificateur ESCLAVE.Appuyer sur le bouton rotatif pour accéder au mode sélectionné. Data Import La LED est à présent ROUGE AL est affiché. Data Import La LED est VERTE . 3sec. 54 .Relâcher le bouton rotatif. 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 4 24V 5 UHF2 6 7 8 24V 9 UHF3 10 UHF Clusters SAT GND CBG-937 Ref.Maintenir le bouton rotatif appuyé.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter Data Data Import + 15V IN Split UHF Exit Output Test (-30 dB) .REMISE A ZERO Cette fonction permet de remettre à zéro tous les filtres et atténuateurs. .Brancher le cordon secteur. . . 0 22 kHz BI-II BIII BI-II BIII 24V VHF-UHF 24V UHF1 18V SAT 13V 0V 1 VHF-UHF 2 3 4 24V 5 UHF2 6 7 8 24V 9 UHF3 10 UHF Clusters SAT GND CBG-937 Ref.2838 MULTICHANNEL PROGRAMMABLE FILTER-AMPLIFIER Stop Channel Manual Level SAT Slope Start Channel Auto Level SAT ON / OFF Select Filter IN Split UHF Exit Output Data Data Import + 15V Test (-30 dB) La version software est affichée suivie d'un point.Débrancher le cordon d'alimentation. 20 dB BI-FM 55 TAP VHF UHF cc BIII VHF-UHF 1 2 UHF 1 cc Att. 30 dB 3 cc UHF 2 4 5 6 7 9 10 SAT Haute puissance Atténuateur général 20 dB SORTIE VHF UHF TAP 8 UHF 3 Niveau auto Test -30 dB cc SAT Pente 9 dB Atténuateur 20 dB 0-22 kHz 0/13/18 V SCHEMA DE PRINCIPE .Att. CARACTERISTIQUES TECHNIQUES Entrées BI-FM BIII VHF-UHF UHF 1 Plage de fréquence (MHz) 47-108 174-240 47-240 + 470-862 470-862 UHF 2 UHF 3 SAT 470-862 470-862 950-2300 8-56 (1 à 7 canaux / filtre) Configuration des - - - Gain (dB) 35 40 40 Atténuateur (dB) 20 20 20 - - - filtres 2 8 0 2 7 1 5 3 2 Réglage de pente (dB) 40 55 20 30 - - 9 - Réglage niveau général UHF (dB) - - Facteur de bruit (dB) 5 5 5 6 9 Niveau d'entrée max.) * TERR. (dBµV) 80 80 80 80 90 Niveau de sortie max. SAT: -35 dB / IM3 56 .* (dBµV) 118 118 VHF:118 / UHF:123 123 Sélectivité - - - - +10 dB à -9 dB 116 SAT / TERR.: -54 dB / IM3 et -30 265 x 220 x 95 Les spécifications peuvent être modifiées sans préavis. > 30 dB - 10 dB / 10 MHz TERR. / SAT > 25 dB Affaiblissement de réflexion (dB) entrée / Sortie >10 >10 - - Téléalimentation commutable >10 >10 >10 >10 >10 24 V 24 V 24 V 24 V 0-13-18 V / 300 mA 100 mA au total Sortie Test (dB) Transfert données 0-22 kHz Connecteur DSUB9 Alimentation 230 V~ / 15 V DC / 45 VA Temperature de fonctionnement -5 à +50°C Dimensions (mm. 57 . 58 . 59 . Ángel Iglesias.com www. S.com . 170 20009 San Sebastián SPAIN Tel.A.ikusi.2006-07 IKUSI .hf@ikusi.: +34 943 44 88 00 fax : +34 943 44 88 19 sales. Paseo Miramón.
Copyright © 2024 DOKUMEN.SITE Inc.