Manual Aire Acondiciona Samsung

March 30, 2018 | Author: 5deivid5 | Category: Air Conditioning, Hvac, Electrical Connector, Relay, Printed Circuit Board


Comments



Description

ROOM AIR CONDITIONERINDOOR UNIT SH09AWH SH09ZWH AQ09WHWE KFR-25G/SWA SH12AWH SH12ZWH AQ12WHWE KFR-35G/SWA OUTDOOR UNIT SH09AWHX SH09ZWHX UQ09WHWE KFR-25W/SWA SH12AWHX SH12ZWHX UQ12WHWE KFR-35W/SWA SERVICE AIR CONDITIONER Manual CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Refrigerating Cycle Diagram 4. Set Up the Model Option 5. Troubleshooting 6. Exploded Views and Parts List 7. Block Diagram 8. Wiring Diagram 9. Schematic Diagram 1. Product Specifications 1-1 Table Model Item Type Cooling Heating Dehumidifying Air Volume Performance Noise Energy Efficiency Ratio Power Power Consumption Operating Current Power Power Factor Starting Current Length Power Cord Number of Core Wire Capacity Outer Dimension Weight(Net) Refrigerant Pipe Drain Hose Size Compressor Oil Type Type Blower Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity Refrigerant to Change(R410A) Protection Device(OLP) Cooling Test Condition Maximum Operation Condition cc g Motor Type Rated Output W Type Motor Type Rated Output Liquid GAS Width x Height x Depth A mm inch kg mm x L(m) mm x L(m) D x L(mm) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW kW |/h m3/min dB W/W V-Hz W A % A m 7.3 8.0 38 / 36 / 34 38 / 36 / 34 2.81 3.22 1-220 / 240-50 980 900 4.5 4.5 96.5 95.5 21.0 250V-10A 825 x 285 x 189 32.5 x 11.2 x 7.44 8.2 ø6.35 x 7.5 ø9.52 x 7.5 ø18 x 550 Rotary Induction Motor(PSC) 900 DAPHNE FV68S(PVE) Cross-flow steel 15 2ROW 14STEP 350 650 MRA99134-9201 INDOOR UNIT : DB27˚C WB19˚C INDOOR UNIT : DB32˚C WB23˚C Propeller steel 50 1ROW 24STEP CAPILLARY TUBE Cross-flow steel 15 2ROW 14STEP 520 1,020 MRA99908-9201 OUTDOOR UNIT : DB35˚C WB24˚C OUTDOOR UNIT : DB43˚C WB26˚C CAPILLARY TUBE 720 x 548 x 265 28.4 x 21.6 x 10.4 31.3 825 x 285 x 189 32.5 x 11.2 x 7.44 8.4 ø6.35 x 7.5 ø9.52 x 7.5 ø18 x 550 Rotary Induction Motor(PSC) 1,075 DAPHNE FV68S(PVE) Propeller steel 50 2ROW 24STEP SH09AWH Indoor unit 2.75 2.90 1.0 25 25 51 / 51 51 / 51 8.3 9.0 41 / 39 / 37 41 / 39 / 37 2.82 3.23 1-220 / 240-50 1,240 1,300 5.7 5.7 98.3 98.0 30.0 250V-10A 720 x 548 x 265 28.4 x 21.6 x 10.4 33.8 Outdoor unit Indoor unit 3.5 4.2 1.4 25 25 53 / 53 53 / 53 SH12AWH Outdoor unit Wall-mounted Wall-mounted Samsung Electronics 1 Table(cont.) Model Item Type Cooling Heating Dehumidifying Air Volume Performance Noise Energy Efficiency Ratio Power Power Consumption Operating Current Power Power Factor Starting Current Length Power Cord Number of Core Wire Capacity Outer Dimension Weight(Net) Refrigerant Pipe Drain Hose Size Compressor Oil Type Type Blower Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity Refrigerant to Change(R22) Protection Device(OLP) Cooling Test Condition Maximum Operation Condition cc g Motor Type Rated Output W Type Motor Type Rated Output Liquid GAS Width x Height x Depth A mm inch kg mm x L(m) mm x L(m) D x L(mm) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW kW |/h m3/min dB W/W V-Hz W A % A m 7.3 8.0 38 / 36 / 34 38 / 36 / 34 2.70 3.22 1-220 / 240-50 1,000 900 4.5 4.0 98.2 99.1 21.0 250V-10A 825 x 285 x 189 32.5 x 11.2 x 7.44 8.2 ø6.35 x 5.0 ø9.52 x 5.0 ø18 x 550 Rotary Induction Motor(PSC) 1,005 SUNISO-4GSD Cross-flow steel 15 2ROW 14STEP 360 580 RAC12110-9622 INDOOR UNIT : DB27˚C WB19˚C INDOOR UNIT : DB32˚C WB23˚C Propeller steel 50 1ROW 24STEP CAPILLARY TUBE steel 15 2ROW 14STEP 600 980 RAC12074-9622 OUTDOOR UNIT : DB35˚C WB24˚C OUTDOOR UNIT : DB43˚C WB26˚C CAPILLARY TUBE Cross-flow 720 x 548 x 265 28.4 x 21.6 x 10.4 31.3 825 x 285 x 189 32.5 x 11.2 x 7.44 8.4 ø6.35 x 5.0 ø12.70 x 5.0 ø18 x 550 Rotary Induction Motor(PSC) 1,206 SUNISO-4GSD Propeller steel 50 2ROW 24STEP Indoor unit 2.70 2.90 1.0 25 25 51 / 51 51 / 51 8.3 9.0 41 / 39 / 37 41 / 39 / 37 2.99 3.48 1-220 / 240-50 1,170 1,150 5.2 5.2 96.9 96.2 30.0 250V-10A 720 x 548 x 265 28.4 x 21.6 x 10.4 33.8 SH09ZWH Outdoor unit Indoor unit 3.5 4.0 1.4 25 25 53 / 53 53 / 53 SH12ZWH Outdoor unit Wall-mounted Wall-mounted 2 Samsung Electronics Model Item Type Cooling Heating Dehumidifying Air Volume Performance Noise Energy Efficiency Ratio Power Power Consumption Operating Current Power Power Factor Starting Current Length Power Cord Number of Core Wire Capacity Outer Dimension Weight(Net) Refrigerant Pipe Drain Hose Size Compressor Oil Type Type Blower Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity Refrigerant to Change(R22) Protection Device(OLP) Cooling Test Condition Maximum Operation Condition cc g Motor Type Rated Output W Type Motor Type Rated Output Liquid GAS Width x Height x Depth A mm inch kg mm x L(m) mm x L(m) D x L(mm) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW kW |/h m3/min dB W/W V-Hz W A % A m 7.3 8.0 AQ09WHWE Indoor unit 2.70 2.90 1.0 25 25 51 / 51 51 / 51 2.70 3.22 1-220 / 240-50 1,000 900 4.5 4.0 98.2 99.1 21.0 250V-10A 825 x 285 x 189 32.5 x 11.2 x 7.44 8.2 ø6.35 x 5.0 ø9.52 x 5.0 ø18 x 550 Rotary Induction Motor(PSC) 1,005 SUNISO-4GSD Cross-flow steel 15 2ROW 14STEP 360 580 RAC12110-9622 INDOOR UNIT : DB27˚C WB19˚C INDOOR UNIT : DB32˚C WB23˚C Propeller steel 50 1ROW 24STEP CAPILLARY TUBE steel 15 720 x 548 x 265 28.4 x 21.6 x 10.4 33.0 8.3 9.0 Outdoor unit AQ12WHWE Indoor unit 3.5 4.0 1.4 25 25 53 / 53 53 / 53 2.99 3.48 1-220 / 240-50 1,170 1,150 5.2 5.2 96.9 96.2 30.0 250V-10A 825 x 285 x 189 32.5 x 11.2 x 7.44 8.4 ø6.35 x 5.0 ø12.70 x 5.0 ø18 x 550 Rotary Induction Motor(PSC) 1,206 SUNISO-4GSD Cross-flow Propeller steel 50 2ROW 24STEP 600 980 RAC12074-9622 OUTDOOR UNIT : DB35˚C WB24˚C OUTDOOR UNIT : DB43˚C WB26˚C CAPILLARY TUBE 720 x 548 x 265 28.4 x 21.6 x 10.4 33.8 Outdoor unit Wall-mounted Wall-mounted 38 / 36 / 34 38 / 36 / 34 41 / 39 / 37 41 / 39 / 37 2ROW 14STEP Samsung Electronics 3 6 x 10.0 25 25 51 / 51 51 / 51 8.35 x 4.4 ø6.0 41 / 39 / 37 41 / 39 / 37 2.2 ø6.000 900 4.99 3.6 4.0 ø18 x 550 Rotary(SAMSUNG) Induction Motor(PSC) 1.5 4.48 1-220-50 1.4 25 25 53 / 53 53 / 53 Outdoor unit Wall-mounted Wall-mounted 4 Samsung Electronics .0 1.3 8.0 250V-10A 825 x 285 x 189 32.210 SUNISO-4GSD/NOC Propeller steel 50 2ROW 24STEP KFR-25G / SWA Indoor unit 2.2 x 7.90 1.4 31.65 2.0 ø9.0 ø18 x 550 Rotary(SAMSUNG) Induction Motor(PSC) 990 SUNISO-4GSD/NOC Cross-flow steel 15 2ROW 14STEP 360 600 RAC12054-9622 INDOOR UNIT : DB27˚C WB19˚C INDOOR UNIT : DB32˚C WB27.5 x 11.150 5.0 250V-16A 720 x 548 x 265 28.8 92 92 30.44 8.5˚C Propeller steel 50 1ROW 24STEP CAPILLARY TUBE Cross-flow steel 15 2ROW 14STEP 600 950 RAC12074-9622 OUTDOOR UNIT : DB35˚C WB24˚C OUTDOOR UNIT : DB43˚C WB33˚C CAPILLARY TUBE 720 x 548 x 265 28.8 5.Table(cont.35 x 4.70 x 4.5 x 11.2 x 7.6 x 10.52 x 4.) Model Item Type Cooling Heating Dehumidifying Air Volume Performance Noise Energy Efficiency Ratio Power Power Consumption Operating Current Power Power Factor Starting Current Length Power Cord Number of Core Wire Capacity Outer Dimension Weight(Net) Refrigerant Pipe Drain Hose Size Compressor Oil Type Type Blower Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity Refrigerant to Change(R22) Protection Device(OLP) Cooling Test Condition Maximum Operation Condition cc g Motor Type Rated Output W Type Motor Type Rated Output Liquid GAS Width x Height x Depth A mm inch kg mm x L(m) mm x L(m) D x L(mm) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW kW |/h m3/min dB W/W V-Hz W A % A m 7.8 Outdoor unit KFR-35G / SWA Indoor unit 3.0 38 / 36 / 34 38 / 36 / 34 2.22 1-220-50 1.1 97 97 21.3 825 x 285 x 189 32.4 33.3 9.4 x 21.4 x 21.65 3.0 ø12.44 8.170 1. Disassembly and Reassembly Stop operation of the air conditioner and remove the power cord before repairing the unit. Remark 2) Open the Front Grille by pulling right and left sides of the hook.2. 3) Loosen 1 of the right screw and detach the Terminal Cover. 2-1 Indoor Unit No 1 Parts Front Grille Procedure 1) Stop the air conditioner operation and block the main power. 5) Loosen 2 fixing screws of Front Grille. Samsung Electronics 5 . 4) Detach the thermistor from the Front Grille. Remark 7) Unlock 3 hooks to fix Panel Front and Back-Body. 3 Tray Drain 1) Pull Tray Drain out from the Back Body. 6 Samsung Electronics . (Inclusion Power Cord) 2) Detach the outdoor unit connection wire from the Terminal Block. 2 Control-In (Main PCB) 1) Take all the connector of PCB upper side out.Disassembly and Reassembly No Parts Procedure 6) Unlock 2 hooks to fix Panel Front and Tray Drain. 3) Loosen 4 fixing screws of Ass'y Control-In. 3) Detach the Fan From the left Holder Bearing. Detach the Holder Pipe at the rear side. Samsung Electronics 7 . Detach the Connection Pipe. Remark 5 Fan Motor & Cross Fan 1) Loosen the fixing screw and detach the Motor Holder. 2) Detach the Fan Motor from the Fan. 5) Lifting the Heat Exchanger up a little to push the up side for separation from the indoor unit.Disassembly and Reassembly No 4 Parts Heat Exchanger 1) 2) 3) 4) Procedure Loosen 2 fixing earth screws of right side. Loosen the 3 fixing screws of right and left side. 4) Loosen 2 fixing screws of the Cabinet-Side LF. 8 Samsung Electronics . Remark 2) Loosen 2 fixing screws of the Ass'y-Control.2-2 Outdoor Unit No 1 Parts Common Work Procedure 1) Loosen each 3 fixing screws on both right and left Cabinet-Side edge and a fixing screw on the Cabinet-Front lower to detach the Cabinet-Front. 3) Loosen 6 fixing screws of the Cabinet-Side RH. (Turn counterclockwise because the screw is right-handed) 2) Detach the Fan. 4 Compressor 1) Loosen the Terminal Cover nut to open the Terminal Cover. 2) Disassemble the pipe in both inlet and outlet with welding torch. 5) Loosen the 3 bolts at the bottom.Disassembly and Reassembly No 2 Parts Fan & Motor Procedure 1) Detach the Nut Flange. 4) Disassemble the pipe in both inlet and outlet of the Condenser with welding torch. 6) Detach the Compressor. 3) Detach the Heat Exchanger. Samsung Electronics 9 . Remark 3 Heat Exchanger 1) Loosen 2 fixing screws on both sides. 3) Loosen 4 fixing screws to detach the Motor. 3) Disassemble the pipe in both inlet and outlet of the Compressor with welding torch. 2) Disassemble the cloth sound felt. Refrigerating Cycle Diagram 3-1 Refrigerating Cycle Diagram Indoor Unit Outdoor Unit ✳Note Capillary tube T1 Liquid side 2-Way valve Check valve Capillary tube Cross fan Heat Exchanger (Evaporator) Heat Exchanger (Evaporator) Propeller fan T2 Gas side 3-Way valve 4-Way valve Cooling Compressor Heating Gas Leak Check Polnt 10 Samsung Electronics .3. (DB/WB C) I 12.0 DB25.0 DB20. Variation : 1.Indoor Temp. Variation : 15.000BTU Heating Capacity Distribution 4.00 0.0 DB20.0˚C ~ 20.3-2 Refrigerating Cycle Characteristic 3-2-1 Capacity Distributions Capacity Distributions according to indoor and outdoor temperature variation.( C) DB15.00 Indoor Temp.00 1.00 1.0/15.00 1.0/0.0 7.0˚C .0/0.00 3.00 1.(DB/WB C) Samsung Electronics 11 .0/15.0˚C ~ 25.00 Heating Capacity(kW) 2.0/6.0 Outdoor Temp.000BTU Heating Capacity Distribution 6. .0 20.00 2.0 Outdoor Temp.0 7.0˚C I 9.Outdoor Temp.0 DB25.0 Heating Capacity 4.00 5.0 3.0 20.0/6.( C) DB15.00 Indoor Temp. 000BTU Power consumption Distribution(Heating mode) 1.0 20.000BTU Power consumption Distribution(Heating mode) 1.0 1.0˚C ~ 20.0/15.0˚C I 9.Outdoor Temp.( C) DB25. Variation : 1.000 DB20.0˚C .0 7.0 Indoor Temp.(DB/WB C) I 12.100 1.0 900 800 700 1.Refrigerating Cycle Diagram 3-2-2 Power Consumption Distributions Power consumption distributions according to indoor and outdoor temperature variation. Variation : 15.400 1.0˚C ~ 25.0/0.( C) DB25.0 Outdoor Temp.000 25 DB15.200 1.300 1.0/6.Indoor Temp.600 1.100 Indoor Temp.0 Power consumption(W) 35 45 Outdoor Temp.500 DB20.0 Power consumption(W) 1. .(DB/WB C) 12 Samsung Electronics .0 DB15. 150 7.10 Power consumption(W) 15.350 Power consumption(Heating) 4.00 1.5 700 7.100 Power consumption(Heating) Power consumption(W) 15.0 Heating Capacity(kW) 1.200 3.Refrigerating Cycle Diagram 3-2-3 Capacity and Power Consumption Distributions Capacity and power consumption distributions according to the length of connecting pipe between indoor unit and outdoor unit.5 15.300 4.00 1. I 9.00 7.0 Length of Connecting Pipe(m) Length of Connecting Pipe(m) I 12.250 3.0 Heating Capacity(kW) 1.00 800 1.000BTU Heating Capacity 4.90 1.000BTU Heating Capacity 4.5 1.5 15.0 Length of Connecting Pipe(m) Length of Connecting Pipe(m) Samsung Electronics 13 .00 900 2.000 3.20 1.80 7. Push the button to set the display panel to . 2 Setting Option SEG2. 1st 2nd Take out the batteries of remote control. Feature Display 1 Setting Option SEG1. : Step 1 : Enter the Option Setup mode..4. the display panel reads . Every time you push the button. Set Up the Model Option 4-1 Setting Option Setup Method ex) Option No. Every time you push the button.. 14 Samsung Electronics .. 5 Setting Option SEG4. repeatedly.. the display panel reads . the display panel reads . Every time you push the button.. repeatedly. 4 Setting Option SEG3. Push the button to set the display panel to . Push the button to set the display panel to .. 3 1. Push the button to set the display panel to .. repeatedly. Every time you push the button.4 2. Press the temperature insert the battery again. the display panel reads .. button simultaneously and 3rd Make sure the remocon display shown as .5 3 Change it into the set display of Option SEG3 and SEG4 with the button. Step 2 : Enter the Option Setup mode and select your option according to the following procedure. repeatedly. the display panel reads . Push the button to set the display panel to ..9 7. repeatedly. Push the button to set the display panel to . 14 Setting Option SEG10. Push the button to set the display panel to .. 7 Setting Option SEG5.Set Up the Model Option Feature Display 6 Change it into the set display of Option SEG5 and SEG6 with the button. the display panel reads .. Every time you push the button. 8 Setting Option SEG6.. the display panel reads .11 9 Change it into the set display of Option SEG7 and SEG8 with the button. Every time you push the button.. Every time you push the button. repeatedly.. Push the button to set the display panel to . 11 Setting Option SEG8. repeatedly. Samsung Electronics 15 .10 8. the display panel reads . Push the button to set the display panel to . the display panel reads . Push the button to set the display panel to . repeatedly. Every time you push the button.. 12 Change it into the set display of Option SEG9 and SEG10 12 13 14 with the button.. Every time you push the button. repeatedly.. 13 Setting Option SEG9. repeatedly. the display panel reads . Every time you push the button.. 10 Setting Option SEG7.. 6.. Plug out. 16 Samsung Electronics . Third. Re-insert the battery into the remote controller. Step 4 : Pressing the ON/OFF button ( ) When pressing the operation ON/OFF key with the direction of remote controller for unit. the sound "Ding" is heard and the OPERATION LED lamp is flickering at the same time. plug in power plug again and press ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code. • Error Mode 1st 2nd If all lamps of indoor unit are flickering. Second. check you made right selections. the set Option will be displayed. (If the "ding" sound isn't heard.Set Up the Model Option Step 3 : Upon completion of the selection. then the input of option is completed.) Step 5 : Unit operation test-run First. Press ON/OFF ( ) key with the direction of remote controller for set. see if the correct option code is set up for its model. try again pressing the ON/OFF button. Whenever you press the button. Remove the battery from the remote controller. 4-2 Table of the option Code Model SEG1 SH12AWH SH12ZWH AQ12WHWE KFR-35G / SWA 2 5 0 2 5 7 0 3 4 0 SEG2 SEG3 SEG4 Option Code SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SH09AWH 2 5 0 2 5 7 0 0 c 8 SH09ZWH AQ09WHWE KFR-25G / SWA 2 5 0 2 5 7 0 0 F b Samsung Electronics 17 . ) Compressor operation is controlled automatically in DRY mode depending on the room temperature and humidity. 5 Compressor of the outdoor unit is operating although it is turned off in a HEAT mode. If none of the basic items are related to the problem. As a phenomenon that the compressor is reoperated after a delay of 3 minutes. the compressor does not operate at a room temperature lower than the setting temperature that indoor fan should operate. The input voltage should be rating voltage ±10% range. When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction of the airconditioner. Explanation It indicates power is on. 5-1 Basic Breakdown Diagnosis Items 1. 18 Samsung Electronics . No 1 Operation of air conditioner The OPERATION indication LED(GREEN) blinks when a power plug of the indoor unit is plugged in for the first time.5. The LED stops blinking if the operation ON/OFF button on the remote control unit is pushed. the compressor does not operate at a room temperature higher than the setting temperature that the INDOOR FAN should operate. In happens after a delay of 3 minutes when the compressor is reoperated. Otherwise the airconditioner may not operate properly. When the unit is turned off while de-ice is activated. The compressor and indoor fan stop intermittently in HEAT mode. Timer is being activated and the unit is in ready mode. 6 Timer LED(GREEN) of the indoor unit lights up and the air conditioner does not operate. please scrutinize the machine according to the 'Breakdown Diagnosis by Symptoms' method. and fan speed of the indoor unit decreases. the indoor fan is adjusted automatically with reference to a temperature of the air blew. The unit operates normally if the timer operation is cancelled. Troubleshooting Check the basic items first to judge if the problem was caused by breakdown or misuse. 9 The compressor stops intermittently in a COOL mode or DRY mode. 7 8 Indoor fan and outdoor fan stop operation intermittently in a HEAT mode. 3. Fan speed is selected automatically in AUTO mode. 2 3 4 Compressor stops operation intermittently in DRY( mode. The compressor operates in a reverse cycle to remove exterior ice in a HEAT mode. Is the link cable linking the indoor unit and the outdoor unit linked properly? The indoor unit and the outdoor unit shall be linked by 5 cables. The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in a HEAT mode. and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heater operation The compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature. The airconditioner may not operate properly if the voltage is out of this range. Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables. The same phenomenon occurs when a power is on. Fan speed setting is not allowed in DRY( ) mode. In a HEAT operation mode. the compressor continues operation for up to 9 minutes (maximum) until the deice is completed. The speed of the indoor fan is set to LL in DRY mode. 2. In a COOL operation mode. • If not. check the voltage between the indoor unit terminal block N(1) and 1. Unable to operate the remote control. the remote control and indoor unit receiver are in trouble. • In 3 minutes. Inspection • Plug out and plug in 5 seconds later. • If it operates. Problem with the relay (RY71) or PCB Samsung Electronics 19 . LAMP Description OPERATION TIMER TURBO Indoor unit room temperature sensor error (open or short) Indoor unit heat exchanger temperature sensor error (open or short) Indoor fan motor mal function EEPROM error Option error (option wasn't set up or option data error) : Lamp off : Lamp flickering 5-2-2 Operation with abnormal motion No 1 Abnormal condition No response from the remote control operation signal. the indoor unit is in trouble. Able to operate the remote control. AC200V ~ AC240V Problem with the outdoor unit or PCB No power source displayed. Initial Diagnosis OK Press the button in the indoor unit. 2 Unable to operate the outdoor unit • Press the TURBO button with the remote control.5-2 Trouble check in the initial status 5-2-1 Diagnosis and marking of the part in trouble. Please check the air conditioner operation status and write the check result in the chart in the room. No Reconnect wires correctly Yes Check whether the fuse on the control board is normal.5VDC) 2.5-3 Breakdown diagnosis by symptoms 5-3-1 No Power (completely dead)-Initial diagnosis 1.5VDC-5.15[A]/250[V] No Replace fuse Yes Check the output of SMPS on the control board. Checklist : 1) Is input voltage normal? 2) Is AC power linked correctly? 3) Is input voltage of DC regulator IC KA7805 (IC02) normal? (11VDC-12.5VDC) 4) Is output voltage of DC regulator IC KA7805 (IC02) normal? (4. Input power: AC230±15%[V] IC02 Input: DC 12[V] IC02 output: DC 5[V] No Replace the control board Yes N Check the setting temperature 20 Samsung Electronics . Troubleshooting procedure Unplug the power cord and plug it after 5 seconds Press the Power Button on the remote control unit to operate the air conditioner does not operate operate N Check the display board N Check the indoor unit control board Check whether two wires of power cord are connected correctly to the terminal block and control board. F701: 3. PCB should be replaced. Fan motor should be replaced. Motor Fan-Capacitor is out of order Yes Replace Motor Fan-Capacitor Fan motor is out of order. Samsung Electronics 21 . Checklist : 1) Is the indoor unit fan motor properly connected with the connector (CN72)? 2) Is the AC voltage correct? 3) Is HALL IC in indoor fan motor properly connected with the connector (CN44)? 4) Is the running capacitor (CR71) properly connected with PCB board? 2. Micom should be replaced Normal Voltage 12V Is the supply voltage of the fan motor sufficient? Test rod location PCB CN72 pin #3 and #5 Condition Fan operate Normal Voltage About AC 180V PCB is out of order. Troubleshooting procedure After unplugging out the power cord should be reconnected within 5 seconds.Troubleshooting 5-3-2 When the Indoor Unit Fan Does Not Operate. (Initial Diagnosis) 1. Yes No Does the OPERATION lamp blink? Check as in the procedure "NO power parts" Yes No Does the Solid State Relay(SS71) work properly? Test rod location + SS71SS71Yes No Micom is out of order. 96kΩ 20°C 12.3kΩ # 22 Samsung Electronics . 3)? 2.38 GND Condition RY71 ON Yes Micom is out of order. Checklist : 1) Is input voltage normal? 2) Is the set temperature of the remote control higher than room temperature in COOL mode? 3) Is the set temperature of the remote control lower than room temperature in HEAT mode? 4) Is the POWER IN connector (CN71) linked correctly? 5) Is the outdoor unit properly connected with the TERMINAL BLOCK connector(N(1). ! Yes No @ Is the room sensor normal register? 10°C 17. Outdoor unit is out of order.Troubleshooting 5-3-3 When the Outdoor Unit Does Not Operate. Normal Voltage PCB should be checked. 1. Troubleshooting procedure After unplugging out the power cord should be reconnected within 5 seconds. Is the power relay RY71 operated by adjusting the room temperature? Test rod location + IC04 Pin No. 2. 1 Yes No Power relay is out of order Power relay should be replaced. No Does the OPERATION lamp blink Check as in the procedure "No Power parts" Yes Yes Room temperature sensor is out of order ! Does the timer lamp blink during operation? No # @ No PCB should be checked.8V Is rating voltage ±10% range applied relay between Terminal block No. N(1) and No. (Initial Diagnosis) 1.09kΩ 30°C 8. DC 4. Troubleshooting 5-3-4 When the UP/DOWN Louver Motor Does Not Operate. 5 seconds. No Is STD lamp blinking? Yes Check as in the procedure "No Power parts". Checklist : 1) Is input voltage normal? 2) Is the UP/DOWN louver motor properly connected with the connector (CN61)? 2. Troubleshooting procedure Remove power cord and plug in again in approx. Does operation start when swing button of the remote control unit pushed? No Yes Normal Voltage at pin #57~#60 of micom (IC04) change? (Squarewave) Yes No Micom (IC04) is faulty. Samsung Electronics 23 . Voltage at pin #16 of IC06(ULN2003A) and #10~#12 of IC08(ULN2003A) change? (Squarewave) Yes No Driver IC06/08 (ULN2003A) is faulty. UP/DOWN louver motor is faulty. (Initial Diagnosis) 1. 1. Troubleshooting procedure After training on.0V? No Abnormal Micom Yes Is the number checking #11 of IC05 (ULN2003A) LOW? No Abnormal Micom Yes Is the voltage between CN71 #1 and CN71 #5 rating voltage ±10% range Yes No Abnormal IC05 Abnormal 4-Way valve of Outdoor Unit. PCB should be replaced.Troubleshooting 5-3-5 In the HEAT mode. When there is no warm air current. 24 Samsung Electronics . No Is the number #38 of Micom (IC04) DC 5. Checklist : 1) Is the set temperature of Remote Control lower than room temperature in Heat mode? 2) Is the Indoor PCB properly connected with the CN71 connector? 2. Check this fist. the heating operation should start in 5 minutes. or connecting Cable No Abnormal RY73 4-Way valve should be replaced or connecting Cable Check. Troubleshooting 5-3-6 Room temperature sensor failure LAMP Description OPERATION TIMER TURBO Indoor unit room temperature sensor error(open or short) : Lamp off : Lamp flickering Detach the assembly sensor from the ASS'Y PCB CN43 connector and measure the sensor resistance with an ohmmeter (tester). supply power.9V? Poor ASS'Y PCB Replace No MICOM Error or Connector(CN43) check Samsung Electronics 25 .83kΩ Connect the sensor to CN43. and measure the voltage of #1 and #2 of the CN43 connector.5V? Poor ASS'Y PCB Replace No Yes Over 4. Yes Below 0.31kΩ SENSOR Resistance Value : 35˚C-6.09kΩ SENSOR Resistance Value : 30˚C-8. Is the sensor resistance value 10KΩ ±3% at the room temperature of 25˚C? Yes No ASS'Y Sensor Replace SENSOR Resistance Value : 20˚C-12.94kΩ SENSOR Resistance Value : 40˚C-5. the assembly module PCB is normal and the main PCB is poor. 26 Samsung Electronics . Assemble the room pipe sensor to PCB.94 5.83 The data tolerance is ±3%. replace the room pipe sensor. If the resistance is below 0. 2~3 of CN91 maintains 5V after the remote control starts operation. 1. 2(-) of the main PCB CN91 while operating the remote control.Troubleshooting 5-3-7 Room Pipe sensor failure LAMP Description OPERATION TIMER TURBO Indoor unit heat exchanger temperature sensor error (open or short) : Lamp off : Lamp flickering 1. Replace the assembly display PCB because the module PCB is poor if the voltage between No.31 6. 2. reassemble the connector accurately.68 12. Put the set in operation and check the voltage of No. Detach the room pipe sensor connector(CN43) and check the resistance between connector 3 and 4. When the voltage descends below 3V. Temperature(˚C) 15 20 25 Resistance Value(Kohm) 14. Then replace the main PCB. 3. Check if the connector was normally assembled.9V. replace the indoor Main PCB.09 10 Temperature(˚C) 30 35 40 Resistance Value(Kohm) 8.5V or over 4. Others If the above data is not met. (short or disconnected in the PCB board) 5-3-8 When the remote control is not receiving. and check the voltage of connector 3 and 4. Check the assembly condition of the sensor connector(CN43) on the indoor unit Main PCB and if not assembled. 2. 3(+) and No. 3. plug in. relay. 2. If the operating lamp twinkles at this time. 5-4-2 Inspection Procedure 1. PIN#6 and GND : 5V) during operation(3 minutes after TURBO operation). But. 1) Check the voltage of the relay(RY71) coil(IC05 PIN #11 and GND : 0V.5-4 PCB Inspection Method 5-4-1 Pre-inspection Notices 1. Inspection Method 1) Is the fuse disconnected? (F701) Cause • Overcurrent • Indoor Fan Motor Short • AC Part Pattern Short of the MAIN PCB 1 2 Checking the power voltage. 3. Check if you pulled out the AC power plug when you eliminate the PCB or front panel. G Display part : LED lamp G Switch part : Switch 5-4-3 Detailed Inspection Procedure No Procedure Plug out and pull the PCB out of the electronic box. • Switching Trans or Power Circuit is faulty 2) Is the voltage between both terminals of the C102 on the 2nd side of the transformer AC12V ±0. exclude the RESERVE operation. Checking the power voltage. and buzzer driving circuit. FAN Speed [High] connector(CN72)? 2. Check connector connection and peeling of PCB or bronze coating pattern when you think the PCB is broken. Continuous Operation 2) The fan motor of the indoor unit doesn't run. sensor driving circuit. the above 1)~3) have no relation. room fan motor driving circuit and control circuit. 2) Check the voltage of both terminals of terminal block 1 and N(1) after 3 minute operation. 1) Is the DB71input voltage AC200V~AC240V? • Power Cord is fault.5V? • Power Circuit is faulty. 2. Don't pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB.5V? 3) Is the voltage between both terminals of OUT and GND of IC02(KA78L05) DC5V ±0. G Main PCB Part : MICOM and surrounding circuit. IC05 is faulty • Relay(RY71) Contact is faulty 4 Press the ON/OFF button. Load Short 3 Press the ON/OFF button and operate TURBO mode. Fuse open. The PCB is composed of the 3 parts. Don't hold the PCB side not impose excessive force on it to eliminate the PCB.: AC220V • Relay(RY71) Coil Disconnection. Supply power. • ASS'Y Main PCB is faulty • Connection is faulty Samsung Electronics 27 . AC Part is faulty. • Fan Motor of the indoor is faulty • Fan Motor Connector(CN72) is faulty 3) The power voltage between terminal #3 and #5 of the connector(CN72) is 0V. power circuit of DC12V and DC5V. Check the PCB fuse. Wrong Power Cable Wiring. 1) Is the voltage over AC180V being imposed on terminal #3 and #5 of the fan motor 1. 960 9 8 7 6 5 4 3 2 1 0 -1 -2 -3 -4 -5 -6 -7 -8 -9 18.537 3.470 29.430 33.828 6.780 11.749 4.772 3.444 4.216 3.313 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 8.060 13.652 3.319 3.116 3.890 35.912 5.700 19.280 15.296 2.Troubleshooting 5-4-4 Temperature Sensor Feature Conversion Table(Room Temperature Sensor).630 12.256 5.729 8.192 7.941 7.050 22.050 38.240 17.161 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 4.426 3.380 10.632 10 10.838 2.570 14.944 9.990 23.669 2.897 4.752 2.699 6.760 40.130 27.900 25.015 8.200 11.439 5.455 7.550 17.300 4.437 2.720 31.040 32.468 6.281 9.512 2.026 4.430 37.560 Temperature Sensor Characteristic Curve Temperature (˚C) 70 60 50 40 30 20 10 0 -10 -9 5 10 15 20 25 30 35 40 At the temperature of 25˚C(10KΩ) Resistance Value (Kohm) 28 Samsung Electronics .280 28.622 8.680 15.150 22.033 6.290 21.560 13.928 3.229 2.594 4.030 26.630 5.246 6.589 2.090 12.365 2.120 14.021 3. 103AT Temperature Sensor Resistance Temperature Sensor Resistance Temperature Sensor Resistance Temperature Sensor Resistance [˚C] [˚C] [˚C] [˚C] [Kohm] [Kohm] [Kohm] [Kohm] 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 2.900 16.080 5.480 20. Open or Short Breakdown Inspection Method Measure the resistance between terminals of the connector (CN72) with a tester. Red Black.5-5 Main Part Inspection Method Part Room Temperature Sensor Measure resistance with a tester Normal Abnormal Room Fan Motor At the normal temperature 37kΩ~ 8. Blue Yellow. 0Ω . Red Resistance 404. Open or Short Measure the resistance between motor wires with a tester. 0Ω . Normal Abnormal About 300Ω at the normal temperature (20˚C ~ 30˚C) ∞.4Ω ± 10% 340Ω ± 10% Remark Main Sub Abnormal Outdoor Fan Motor ∞. Normal At the normal temperature (10˚C ~ 30˚C) Compare terminal Yellow. . . ∞. . . 0Ω . Open or Short Measure the resistance between the red wire and each terminal wire with a tester. . . . Yellow Resistance 360Ω ± 10% 328Ω ± 10% Remark Main Sub Abnormal Stepping Motor ∞.3kΩ(-7˚C~+30˚C) *Refer to Table 5-4-4. Normal At the normal temperature (10˚C ~ 30˚C) Compare terminal Yellow. Open or Short Samsung Electronics 29 . . 0Ω . 6.sec.co.kr 30 Samsung Electronics .samsung. Exploded Views and Parts List 6-1 Indoor Unit 6 7 1 1-2 1-7 1-8 1-1 1-3 1-5 2 1-6 1-4 4 2-1 9 2-3 2-2 5 5-1 3-6 3-8 3-4 3-8-1 5-4 3 3-1 3-7 3-2 5-2 5-3 3-3 3-5 8 You can search for the updated part code number through the ITSELF. URL : http://itself. DB94-00454B DB61-01632A DB69-00834A DB61-01634A DB31-00219A DB94-00456A DB97-02075A DB73-00181A DB94-40007A DB96-03112A DB96-03112B Description ASS'Y-BACK BODY BACK-BODY CUSHION-BACK BODY SUPPORTER-EVAP RH MOTOR-IN ASS'Y-CROSS FAN ASS'Y BOLT-SPECIAL RUBBER-BEARING MOLD-BEARING ASS'Y CYCLE IN ASS'Y CYCLE IN COVER BEARING SPACE-EVAP-LOW ASS'Y-EVAP TOTAL ASS'Y-EVAP TOTAL ASS'Y-TRAY DRAIN TRAY-DRAIN BLADE-H BLADE-V STABILIZER CUSHION-TRAY RH RUBBER-CAP ASS'Y-STEPPING-MOTOR ASS'Y DRAIN HOSE CLIP TERMINAL HOSE ASS'Y-CONTROL IN ASS'Y-PANEL FRONT PANEL-FRONT GRILLE-AIR INLET ASS'Y-COVER DISPLAY GUARD-AIR FILTER PLATE-HANGER HOLDER-PIPE COVER TERMINAL ASS'Y-REMOCON ASS'Y HIPS EPS HIPS Specification SH09AWH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 Remark SH12AWH 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 Refer to page 40 YDK-20S4F8C-1 OD92x635 ASS'Y RUBBER BEARING ASS'Y ASS'Y ABS PVC 1.5S. PI1.Exploded Views and Parts List I Parts List Q'TY No.6x320x650 PS ABS-V0 REMOCON 2-1 2-2 2-3 DB63-00850A DB60-00118A DB96-04716A DB96-04716B 3 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-8-1 4 5 5-1 5-2 5-3 5-4 6 7 8 9 DB94-00457D DB63-00848A DB61-01635A DB61-01636A DB63-00849A DB69-00839A DB73-00180A DB95-20138A DB94-00458B DB61-01715A DB93-02481L DB92-00536A DB64-00989A DB64-00990A DB97-02064A DB63-00846A DB70-00406A DB61-01638A DB63-00844A DB93-02532B Samsung Electronics 31 . 2x14 1. 1 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 2 Code No.3S. 24BYJ48 ASS'Y STS.0 ASS'Y ASS'Y PS HIPS ASS'Y PP SGCC-M T0. 2x14 ASS'Y ABS HIPS PP ABS EPS30 GUM-EPM PM24-600g. 3S.Exploded Views and Parts List I Parts List(cont. 24BYJ48 ASS'Y STS. Code No.0 ASS'Y ASS'Y PS HIPS ASS'Y PP SGCC-M T0. PI1.5S. Description Specification SH09ZWH AQ09WHWE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 SH12ZWH AQ12WHWE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 Remark 1 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 2 DB94-00454B DB61-01632A DB69-00834A DB61-01634A DB31-00219A DB94-00456A DB97-02075A DB73-00181A DB94-40007A DB96-03112C DB96-03112D ASS'Y-BACK BODY BACK-BODY CUSHION-BACK BODY SUPPORTER-EVAP RH MOTOR-IN ASS'Y-CROSS FAN ASS'Y BOLT-SPECIAL RUBBER-BEARING MOLD-BEARING ASS'Y CYCLE IN ASS'Y CYCLE IN COVER BEARING SPACE-EVAP-LOW ASS'Y-EVAP ASS'Y-EVAP ASS'Y-TRAY DRAIN TRAY-DRAIN BLADE-H BLADE-V STABILIZER CUSHION-TRAY RH RUBBER-CAP ASS'Y-STEPPING-MOTOR ASS'Y DRAIN HOSE CLIP TERMINAL HOSE ASS'Y-CONTROL IN ASS'Y-PANEL FRONT PANEL-FRONT GRILLE-AIR INLET ASS'Y-COVER DISPLAY GUARD-AIR FILTER PLATE-HANGER HOLDER-PIPE COVER TERMINAL ASS'Y-REMOCON ASS'Y HIPS EPS HIPS YDK-20S4F8C-1 OD92x635 ASS'Y RUBBER BEARING ASS'Y ASS'Y ABS PVC 1. 2x14 ASS'Y ABS HIPS PP ABS EPS30 GUM-EPM PM24-600g.) Q'TY No. 2x14 1.6x320x650 PS ABS-V0 REMOCON 2-1 2-2 2-3 DB63-00850A DB60-00118A DB96-03060A DB96-03257A 3 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-8-1 4 5 5-1 5-2 5-3 5-4 6 7 8 9 DB94-00457D DB63-00848A DB61-01635A DB61-01636A DB63-00849A DB69-00839A DB73-00180A DB95-20138A DB94-00458B DB61-01715A DB93-02481✳ DB92-00536A DB64-00989A DB64-00990A DB97-02064A DB63-00846A DB70-00406A DB61-01638A DB63-00844A DB93-02532B Refer to page 40 32 Samsung Electronics . 2x14 1.Exploded Views and Parts List I Parts List(cont.5S.) Q'TY No. 1 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 2 Code No. 2x14 ASS'Y ABS HIPS PP ABS EPS30 GUM-EPM PM24-600g.6x320x650 PS ABS-V0 REMOCON 2-1 2-2 2-3 DB63-00850A DB60-00118A DB96-03060A DB96-03257A 3 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-8-1 4 5 5-1 5-2 5-3 5-4 6 7 8 9 DB94-00457D DB63-00848A DB61-01635A DB61-01636A DB63-00849A DB69-00839A DB73-00180A DB95-20138A DB94-00458B DB61-01715A DB93-02481✳ DB92-00536B DB64-00989A DB64-00990A DB97-02064A DB63-00846B DB70-00406A DB61-01638A DB63-00844A DB93-02532D Refer to page 40 Samsung Electronics 33 .0 ASS'Y ASS'Y PS HIPS ASS'Y PP SGCC-M T0. DB94-00454B DB61-01632A DB69-00834A DB61-01634A DB31-00219A DB94-00456A DB97-02075A DB73-00181A DB94-40007A DB96-03112C DB96-03112D Description ASS'Y-BACK BODY BACK-BODY CUSHION-BACK BODY SUPPORTER-EVAP RH MOTOR-IN ASS'Y-CROSS FAN ASS'Y BOLT-SPECIAL RUBBER-BEARING MOLD-BEARING ASS'Y CYCLE IN ASS'Y CYCLE IN COVER BEARING SPACE-EVAP-LOW ASS'Y-EVAP ASS'Y-EVAP ASS'Y-TRAY DRAIN TRAY-DRAIN BLADE-H BLADE-V STABILIZER CUSHION-TRAY RH RUBBER-CAP ASS'Y-STEPPING-MOTOR ASS'Y DRAIN HOSE CLIP TERMINAL HOSE ASS'Y-CONTROL IN ASS'Y-PANEL FRONT PANEL-FRONT GRILLE-AIR INLET ASS'Y-COVER DISPLAY GUARD-AIR FILTER PLATE-HANGER HOLDER-PIPE COVER TERMINAL ASS'Y-REMOCON ASS'Y HIPS EPS HIPS Specification KFR-25G / SWA KFR-35G / SWA 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 Remark YDK-20S4F8C-1 OD92x635 ASS'Y RUBBER BEARING ASS'Y ASS'Y ABS PVC 1.3S. PI1. 24BYJ48 ASS'Y STS. 5S. Description Specification SH09ZWH (RUSSIA) SH12ZWH (RUSSIA) Remark 1 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 2 DB94-00454B DB61-01632A DB69-00834A DB61-01634A DB31-00219A DB94-00456A DB97-02075A DB73-00181A DB94-40007A DB96-03112C DB96-03112D ASS'Y-BACK BODY BACK-BODY CUSHION-BACK BODY SUPPORTER-EVAP RH MOTOR-IN ASS'Y-CROSS FAN ASS'Y BOLT-SPECIAL RUBBER-BEARING MOLD-BEARING ASS'Y CYCLE IN ASS'Y CYCLE IN COVER BEARING SPACE-EVAP-LOW ASS'Y-EVAP ASS'Y-EVAP ASS'Y-TRAY DRAIN TRAY-DRAIN BLADE-H BLADE-V STABILIZER CUSHION-TRAY RH RUBBER-CAP ASS'Y-STEPPING-MOTOR ASS'Y DRAIN HOSE CLIP TERMINAL HOSE ASS'Y-CONTROL IN ASS'Y-PANEL FRONT PANEL-FRONT GRILLE-AIR INLET ASS'Y-COVER DISPLAY GUARD-AIR FILTER PLATE-HANGER HOLDER-PIPE COVER TERMINAL ASS'Y-REMOCON ASS'Y HIPS EPS HIPS YDK-20S4F8C-1 OD92x635 ASS'Y RUBBER BEARING ASS'Y ASS'Y ABS PVC 1.Exploded Views and Parts List I Parts List(cont.0 ASS'Y ASS'Y PS HIPS ASS'Y PP SGCC-M T0.3S.6x320x650 PS ABS-V0 REMOCON 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 Refer to page 40 2-1 2-2 2-3 DB63-00850A DB60-00118A DB96-03060A DB96-03257A 3 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-8-1 4 5 5-1 5-2 5-3 5-4 6 7 8 9 DB94-00457D DB63-00848A DB61-01635A DB61-01636A DB63-00849A DB69-00839A DB73-00180A DB95-20138A DB94-00458B DB61-01715A DB93-02481✳ DB92-00536A DB64-00989A DB64-00990A DB97-02064A DB63-00846A DB70-00406A DB61-01638A DB63-00844A DB93-02532B 34 Samsung Electronics . 2x14 ASS'Y ABS HIPS PP ABS EPS30 GUM-EPM PM24-600g. Code No.) Q'TY No. PI1. 2x14 1. 24BYJ48 ASS'Y STS. 5S.Exploded Views and Parts List I Parts List(cont. 2x14 1.6x320x650 PS ABS-V0 REMOCON 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 Refer to page 40 2-1 2-2 2-3 DB63-00850A DB60-00118A DB96-03060A DB96-03257A 3 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-8-1 4 5 5-1 5-2 5-3 5-4 6 7 8 9 DB94-00457D DB63-00848A DB61-01635A DB61-01636A DB63-00849A DB69-00839A DB73-00180A DB95-20138A DB94-00458B DB61-01715A DB93-02481✳ DB92-00536A DB64-00989A DB64-00990A DB97-02064A DB63-00846A DB70-00406A DB61-01638A DB63-00844A DB93-02532B Samsung Electronics 35 . 24BYJ48 ASS'Y STS. Description Specification SH09ZWH (AUSTRALIA) SH12ZWH (AUSTRALIA) Remark 1 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 2 DB94-00454B DB61-01632A DB69-00834A DB61-01634A DB31-00219A DB94-00456A DB97-02075A DB73-00181A DB94-40007A DB96-03112C DB96-03112D ASS'Y-BACK BODY BACK-BODY CUSHION-BACK BODY SUPPORTER-EVAP RH MOTOR-IN ASS'Y-CROSS FAN ASS'Y BOLT-SPECIAL RUBBER-BEARING MOLD-BEARING ASS'Y CYCLE IN ASS'Y CYCLE IN COVER BEARING SPACE-EVAP-LOW ASS'Y-EVAP ASS'Y-EVAP ASS'Y-TRAY DRAIN TRAY-DRAIN BLADE-H BLADE-V STABILIZER CUSHION-TRAY RH RUBBER-CAP ASS'Y-STEPPING-MOTOR ASS'Y DRAIN HOSE CLIP TERMINAL HOSE ASS'Y-CONTROL IN ASS'Y-PANEL FRONT PANEL-FRONT GRILLE-AIR INLET ASS'Y-COVER DISPLAY GUARD-AIR FILTER PLATE-HANGER HOLDER-PIPE COVER TERMINAL ASS'Y-REMOCON ASS'Y HIPS EPS HIPS YDK-20S4F8C-1 OD92x635 ASS'Y RUBBER BEARING ASS'Y ASS'Y ABS PVC 1.0 ASS'Y ASS'Y PS HIPS ASS'Y PP SGCC-M T0.) Q'TY No. PI1. Code No.3S. 2x14 ASS'Y ABS HIPS PP ABS EPS30 GUM-EPM PM24-600g. 6-2 Outdoor Unit 22 17-1 17-2 17-5 20 21 17 17-3 17-4 17-6 16 17-7 17-9 17-8 10 3 9 11 7 13 12 6 8 3-2 3-1 19 19-4 19-3 17-10 19-2 19-1 4 18 1 15 14 2 5 36 Samsung Electronics . 1 2 3 3-1 3-2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17-1 17-2 17-3 17-4 17-5 17-6 17-7 17-8 17-9 17-10 18 19 19-1 19-2 19-3 19-4 20 21 22 Code No. T1.6. SGCC-M. FP1. 378g ASS'Y T0. 422g SH09AWHX 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 SH12AWHX 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - 2x24. T0.7.Exploded Views and Parts List I Parts List Q'TY No. 66g T1. SANYO 1 1 1 1 1 1 1 Samsung Electronics 37 . SECC-P T1.6. SECC-P ABS-V0. LOUVER 1x24. T0.5µFx450V WIRE.6 ASS'Y. DB90-01341A DB63-00847A DB90-01332A DB64-01094A DB64-00992A DB90-01331A DB63-00853A DB90-01330A DB90-01330B DB99-00401A DB94-00459C DB94-00459B DB61-01644A DB97-02225A DB97-02225B DB31-00220A DB67-00397A DB60-30004A DB63-00815A DB63-00763A DB60-30028A DB96-03061A DB96-03172A DB93-02554A DB93-02554B DB61-01642A 2501-001236 2501-001237 2301-001375 DB65-40049E DB65-10046A DB61-00250A DB93-50062C DB93-00481H DB93-00481J DB33-00050A DB35-00029A DB35-00029B DB72-00726A DB72-00726B DB95-00468A DB95-00467A DB95-00501A DB95-00534A DB63-00943A DB63-00999A DB63-00942A DB60-30018A DB96-03062A DB96-03049A DB99-00445A DB99-00413A DB71-00090A DB71-00090B Description ASS'Y-CABI FRONT GUARD-FAN ASS'Y CABI SIDE LF CABI SIDE LF(COATING) HANDLE LF ASS'Y CABI SIDE RH COVER-CONTROL ASS'Y-BASE ASS'Y-BASE ASS'Y BRACKET VALVE ASS'Y-PARTITION ASS'Y-PARTITION BRACKET-MOTOR ASS'Y PLATE SUPPORT B/M ASS'Y PLATE SUPPORT B/M MOTOR-OUT PROPELLER-FAN NUT FLANGE GROMMET GROMMET NUT WASHER ASS'Y-COND ASS'Y-COND ASS'Y-CONTROL OUT ASS'Y-CONTROL OUT CASE-CONTROL OUT CAPACITOR-COMP CAPACITOR-COMP CAPACITOR-MOTOR TERMINAL-BLOCK CLIP-CAPACITOR HOLDER-WIRE LEAD WIRE ASS'Y LEAD WIRE ASS'Y LEAD WIRE SOLENOID-ASS'Y OLP OLP SPONGE-FELT COMP CLOTH SPONGE-FELT COMP CLOTH ASS'Y-COMP ASS'Y-COMP COMP COMP GASKET GASKET COVER-TERMINAL NUT FLANGE ASS'Y CHECK VALVE ASS'Y CAPILLARY ASS'Y 4WAY VALVE ASS'Y 4WAY VALVE BAR-STEEL BAR-STEEL ASS'Y ASS'Y ASS'Y ASS'Y NR NR Specification T0. FP1. LOUVER ASS'Y ASS'Y SGCC-M T0. SANYO 802 141 55.6x370x490 ASS'Y ASS'Y YDK-25F6M13E-1 AS+G/F 20%.0x95x235 ASS'Y.5.5.6x150x250 30µFx450V 35µFx450V 1. SGCC-M.0. SECD-P PP. SECC-P SECC-P. ASS'Y MRA99908-9201 MRA99134-9201 FELT+PVC FELT+PVC 1 1 1 1 802 354 45.6 SGCC-M T0.0. SECC-P PP. 30g T0. SECC-P PP. 422g 38 Samsung Electronics .6. SGCC-M. SECD-P PP.0x95x235 ASS'Y.0.6x370x490 ASS'Y ASS'Y YDK-25F6M13E-1 AS+G/F 20%.7. Code No.6 ASS'Y. 378g ASS'Y T0.) Q'TY No. SECC-P ABS-V0. SGCC-M.0. SECC-P T1.5.6. 30g T0. 66g T1.5µFx450V 3 3 1 1 1 1 1 1 1 1 1 1 WIRE. SECC-P SECC-P. Description Specification SH09ZWHX UQ09WHWE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 NR NR 2x24. FP1. T1. FP1. T0.6x150x250 30µFx450V 40µFx450V 1. LOUVER ASS'Y ASS'Y SGCC-M T0.6 SGCC-M T0. T0. LOUVER 1x24.5.Exploded Views and Parts List I Parts List(cont. ASS'Y RAC12074-9622 RAC12110-9622 FELT+PVC FELT+PVC 1 1 1 1 SEC SEC 1 1 1 1 ASS'Y ASS'Y ASS'Y ASS'Y 1 1 1 SH12ZWHX UQ12WHWE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - 1 2 3 3-1 3-2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17-1 17-2 17-3 17-4 17-5 17-6 17-7 17-8 17-9 17-10 18 19 19-1 19-2 19-3 19-4 20 21 22 DB90-01341A DB63-00847A DB90-01332A DB64-01094A DB64-00992A DB90-01331A DB63-00853A DB90-01330E DB90-01330B DB99-00401A DB94-00459C DB94-00459B DB61-01644A DB97-02225A DB97-02225B DB31-00220A DB67-00397A DB60-30004A DB63-00815A DB63-00763A DB60-30028A DB96-03580A DB96-03581A DB93-02748A DB93-02748B DB61-01642A 2501-001236 2501-001238 2301-001375 DB65-40049E DB65-10046A DB61-00250A DB93-50062C DB93-00481H DB33-00050A DB35-00030C DB35-00020G DB72-00726E DB72-00726D DB95-00552A DB95-00551A 48D129JU1EL 44B102JX1EL DB63-20002A DB63-10165D DB60-30018A DB99-00453A DB99-00478A DB99-00475A DB99-00477A DB71-00090A DB71-00090B ASS'Y-CABI FRONT GUARD-FAN ASS'Y CABI SIDE LF CABI SIDE LF(COATING) HANDLE LF ASS'Y CABI SIDE RH COVER-CONTROL ASS'Y-BASE ASS'Y-BASE ASS'Y BRACKET VALVE ASS'Y-PARTITION ASS'Y-PARTITION BRACKET-MOTOR ASS'Y PLATE SUPPORT B/M ASS'Y PLATE SUPPORT B/M MOTOR-OUT PROPELLER-FAN NUT FLANGE GROMMET GROMMET NUT WASHER ASS'Y-COND ASS'Y-COND ASS'Y-CONTROL OUT ASS'Y-CONTROL OUT CASE-CONTROL OUT CAPACITOR-COMP CAPACITOR-COMP CAPACITOR-MOTOR TERMINAL-BLOCK CLIP-CAPACITOR HOLDER-WIRE LEAD WIRE ASS'Y LEAD WIRE SOLENOID-ASS'Y OLP OLP SPONGE-FELT COMP CLOTH SPONGE-FELT COMP CLOTH ASS'Y-COMP ASS'Y-COMP COMP COMP GASKET COVER-TERMINAL NUT FLANGE ASS'Y CHECK VALVE ASS'Y CHECK VALVE ASS'Y 4WAY VALVE ASS'Y 4WAY VALVE BAR-STEEL BAR-STEEL T0. 0. SECC-P PP.6x150x250 30µFx450V 35µFx450V 1.6.0. 30g T0.) Q'TY No.5. 1 2 3 3-1 3-2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17-1 17-2 17-3 17-4 17-5 17-6 17-7 17-8 17-9 17-10 18 19 19-1 19-2 19-3 19-4 20 21 22 Code No.6. SECC-P T1.5. 66g T1. ASS'Y RAC12074-9622 RAC12054-9622 FELT+PVC FELT+PVC 1 1 1 1 1 1 1 1 1 1 1 KFR-35W / SWA 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - Samsung Electronics 39 . FP1.0x95x235 ASS'Y.6x370x490 ASS'Y ASS'Y YDK-25F6M13E-1 AS+G/F 20%.6 SGCC-M T0. SECD-P PP.6 ASS'Y. LOUVER ASS'Y ASS'Y SGCC-M T0.5µFx450V 1 1 1 1 1 1 1 1 1 1 WIRE.Exploded Views and Parts List I Parts List(cont. 378g ASS'Y T0. LOUVER 1x24.7. T1. 422g 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 2x24. SGCC-M. DB90-01341A DB63-00847A DB90-01332A DB64-01094A DB64-00992A DB90-01331A DB63-00853A DB90-01330E DB90-01330B DB99-00401A DB94-00459D DB94-00459E DB61-01644A DB97-02225A DB97-02225B DB31-00220A DB67-00397A DB60-30004A DB63-00815A DB63-00763A DB60-30028A DB96-03580A DB96-03581A DB93-02748C DB93-02748D DB61-01642A 2501-001236 2501-001237 2301-001375 DB65-40049H DB65-10046A DB61-00250A DB93-50062C DB93-00481H DB33-00050A DB35-00030C DB35-00030A DB72-00726E DB72-00726D DB95-00543B DB94-00542B 48D129MXAEL 44B102MXAEL DB63-20002A DB63-10165D DB60-30018A DB99-00453A DB99-00478B DB99-00475A DB99-00491A DB71-00090A DB71-00090B Description ASS'Y-CABI FRONT GUARD-FAN ASS'Y CABI SIDE LF CABI SIDE LF(COATING) HANDLE LF ASS'Y CABI SIDE RH COVER-CONTROL ASS'Y-BASE ASS'Y-BASE ASS'Y BRACKET VALVE ASS'Y-PARTITION ASS'Y-PARTITION BRACKET-MOTOR ASS'Y PLATE SUPPORT B/M ASS'Y PLATE SUPPORT B/M MOTOR-OUT PROPELLER-FAN NUT FLANGE GROMMET GROMMET NUT WASHER ASS'Y-COND ASS'Y-COND ASS'Y-CONTROL OUT ASS'Y-CONTROL OUT CASE-CONTROL OUT CAPACITOR-COMP CAPACITOR-COMP CAPACITOR-MOTOR TERMINAL-BLOCK CLIP-CAPACITOR HOLDER-WIRE LEAD WIRE ASS'Y LEAD WIRE SOLENOID-ASS'Y OLP OLP SPONGE-FELT COMP CLOTH SPONGE-FELT COMP CLOTH ASS'Y-COMP ASS'Y-COMP COMP COMP GASKET COVER-TERMINAL NUT FLANGE ASS'Y CHECK VALVE ASS'Y CHECK VALVE ASS'Y 4WAY VALVE ASS'Y 4WAY VALVE BAR-STEEL BAR-STEEL ASS'Y ASS'Y ASS'Y ASS'Y SSEC SSEC NR NR Specification KFR-25W / SWA T0. SECC-P ABS-V0. T0. T0. FP1. SGCC-M. SECC-P SECC-P. AQ09WHWE/FES. 120x90 4P FR-1. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Code No. DB61-01637A DB93-02482A DB65-00140A DB93-02483A DB61-01639A DB61-00171A DB39-00949A DB39-00147D DB32-00020D DB63-00851A CASE-CONTROL ASS'Y PCB MAIN Description ABS Specification Q'TY 1 1 1 1 1 1 1 2 1 1 1 1 1 1 Remark FR-4. DB93-02481G DB93-02481J KFR-35G/SWA KFR-25G/SWA MODEL DB93-02481C DB93-02481E SH09ZWH/XSA. T1-2 ABS PH M3xL22 TH M4xL16 TH M4xL10 8P 5P 4P(103AT) HIPS 3P ASS'Y TERMINAL BLOCK ASS'Y S/W & MODULE & DISPLAY PCB PLATE-CONTROL HOLDER-WIRE CLAMP SCREW-MACHINE SCREW-MACHINE SCREW-MACHINE CONNECTOR WIRE S/W & MODULE & DISPLAY CONNECTOR WIRE STEP MOTOR UP/DOWN ASS'Y THERMISTOR WIRE COVER CLAMP POWER CORD SNA SNA SNA 40 Samsung Electronics .6-3 Ass'y-Control In(Code No : DB93-02481✳) Code No. DB93-02481L MODEL SH09AWH/EDC. SH12ZWH/XSA SH09ZWH/SER. SH12AWH/EDC. 30x70 SGCC-M. SH12ZWH/XFO I Parts List No. SH12ZWH/EDC. AQ12WHWE/FES Code No. SH09ZWH/XFO. SH12ZWH/SER. SH09ZWH/EDC. COOL.7. DRY. HEAT) INDOOR FAN MOTOR TURBO OPERATION 1HR TIMER • COMPRESSOR DRIVE • OUTDOOR FAN MOTOR DRIVE • STEPPING MOTOR DRIVE FLAP • BUZZER DRIVE • 4-WAY VALVE DRIVE ON. FAN. Block Diagram CONTROLLER IC-MCU HEAT EXCHANGER SENSOR ROOM TEMPERATURE SENSOR INFRARED SIGNAL RESET CIRCUIT • BLADE CONTROL • INDOOR FAN MOTOR CONTROL • COMPRESSOR CONTROL • TEMPERATURE CONTROL • TIMER • BUZZER CONTROL • OUTDOOR FAN MOTOR CONTROL • 4-WAY VALVE CONTROL DISPLAY PART OPERATION TIMER TURBO OSCILLATION CIRCUIT ZERO VOLTAGE DETECT REMOTE CONTROL • COMPRESSOR CONTROL SIGNAL POWER ON/OFF • STEPPING MOTOR CONTROL SIGNAL • BUZZER CONTROL SIGNAL • OUTDOOR FAN MOTOR CONTROL SIGNAL • 4-WAY VALVE CONTROL SIGNAL SSR TRIGGER SIGNAL MODE (AUTO. OFF TIMER SELECT STEPPING MOTOR : BLADE UP/DOWN BUZZER COMPRESSOR OUTDOOR FAN MOTOR 4-WAY VALVE FAN SPEED SELECT (H/M/L) TEMPERATURE SELECT DC 5V VOLTAGE REGULATOR SLEEP SELECT DC 12V SMPS POWER BLOCK BATTERY CHECK ENERGY SAVING AC INPUT Samsung Electronics 41 . Wiring Diagram 8-1 Indoor Unit Code No : DB98-15138A This Document can not be used without Samsung's authorization.8. 42 Samsung Electronics . P FAN MOTOR OVER LOAD PROTECTOR Code No : DB98-15607A This Document can not be used without Samsung's authorization.8-2 Outdoor Unit C1 C2 MOTOR CAPACITOR COMP CAPACITOR FM1 O. Samsung Electronics 43 .L. 9. Schematic Diagram 9-1 Indoor Unit This Document can not be used without Samsung's authorization. 44 Samsung Electronics . . Printed in Korea. Ltd. Apr.ELECTRONICS This Service Manual is a property of Samsung Electronics Co. 2004.. DB98-15924A(3-1) . Any unauthorized use of Manual can be punished under applicable International and/or domestic law. Code No. © Samsung Electronics Co. Ltd.
Copyright © 2024 DOKUMEN.SITE Inc.